1.1.2 During Power ON<br />

Danger<br />

Chapte 1 Safety Precautions<br />

Do not plug or unplug the connectors on the inverter when electrified to avoid the<br />

control panel damage resulting from erratic transition voltage surge due to contact<br />

bounce.<br />

When momentary power loss is longer than 2 seconds (the larger of horse power, the<br />

longer of time), the inverter does not have enough storage power to control the circuit;<br />

Therefore, when power is regenerated, the operation of the inverter is based on the<br />

setup of 1-00 / 2-05 and the condition of external switch, this is considered to be<br />

「restart」in the following paragraphs.<br />

When the momentary power loss is short, the inverter still has enough storage power<br />

to control the circuit. Therefore, when power is regenerated, the inverter will<br />

automatically restart depending on the setup of 2-00/2-01.<br />

When restart the inverter, the operation of the inverter is based on the setup of 1-00<br />

and 2-05 and the condition of external switch (FWD/REV button). Attention: the<br />

start operation is irrelevant with 2-00/2-01/2-02/2-03.<br />

1. When 1-00=0000, the inverter will not automatically run after restart.<br />

2. When 1-00=0001 and the external switch (FWD/REV button) is OFF, the inverter<br />

will not run after restart.<br />

3. When 1-00=0001, the external switch (FWD/REV button) is ON, and 2-05=0000,<br />

the inverter will run automatically after restart. Attention: In the sake of safety,<br />

please turn off the external switch (FWD/REV button) after power loss to avoid<br />

underling damage to the machine and the human body after sudden regeneration of<br />

power.<br />

To ensure the safety of people and machine, please refer to the description and<br />

suggestion of 2-05<br />

1.1.3 Before Operation<br />

Danger<br />

Make sure the model and capacity are the same as those set by 15-0.<br />

Caution<br />

The inverter will flash the power voltage set by 0-07 for 5 seconds when applying power.<br />