1.1.4 During Operation<br />
Danger<br />
Chapte 1 Safety Precautions<br />
Do not engage or disengage the motor during operation. Otherwise, the over-current will<br />
cause the inverter to disconnect or the main circuit to burn.<br />
Danger<br />
To avoid electric shock, do not take the front cover off during electrifying<br />
The motor will restart automatically after stop when auto-restart function is on. In this<br />
case, do not get close to the machine.<br />
Note: The stop switch is different from the usage of the emergency stop switch. It must<br />
be set first to be effective.<br />
Caution<br />
Do not touch heat-generating components such as heat sink and braking resistor.<br />
The inverter can drive the motor running from low speed to high speed. Verify the<br />
allowable capacities range of the motor and the mechanism.<br />
Note the settings related to the braking reactor.<br />
Do not check signals on circuit boards while the inverter is running.<br />
Caution<br />
It is after 5 minutes that disassembling or checking the components could be performed as<br />
power supply OFF and the indicator turned off.<br />
1.1.5 During Maintenance<br />
Caution<br />
The inverter should be used in a non-condensed environment with temperature from –10<br />
to +40 and relative humidity of 95% non-condense.<br />
Caution<br />
When the inverter top cover has removed, it can be used in a non-condensed environment<br />
with temperature from –10 to +50 and relative humidity of 95%, but the environment<br />
should be free from water and metal dust.<br />
1-3