<strong>TECHNICAL</strong> UPDATE<br />

Date: 25/07/2008 Sheet 1 of 24<br />

<strong>MANUAL</strong> <strong>AFFECTED</strong>: <strong>TECHNICAL</strong> <strong>MANUAL</strong><br />

<strong>EASICOOL</strong> <strong>DF</strong> - R410A<br />

<strong>MANUAL</strong> PART NO: 6662647 ISSUE 01-2008<br />

CHANGE: INTRODUCTION OF EC FAN<br />

MOTOR OPTION<br />

CONTENTS TO BE READ IN CONJUCTION WITH <strong>TECHNICAL</strong> <strong>MANUAL</strong>:<br />

INDOOR UNIT 2<br />

Optional Extras - Energy Saving 2<br />

Dimensions 3<br />

Positioning 5<br />

Minimum Unit Clearance 5<br />

Weights 6<br />

Sound Data 6<br />

Mechanical Data - Air & Water Cooled Models 7<br />

Electrical Data - Air & Water Cooled Models 11<br />

Mechanical Data - Chilled Water models 15<br />

Electrical Data - Chilled Water Models 19<br />

OUTDOOR UNIT 21<br />

Dimensions / Weights / Positioning - Horizontal 21<br />

Dimensions / Weights / Positioning - Vertical 22<br />

Unit Lifting 23<br />

Airedale International Air Conditioning Ltd<br />

Leeds Road, Rawdon, Leeds. LS19 6JY England<br />

Tel: + 44 (0) 113 239 1000 Fax: + 44 (0) 113 250 7219<br />

E-mail: enquiries@airedale.com Website: www.airedale.com<br />

Airedale reserve the right to change specifications without prior notice, information correct at time of printing. E


<strong>TECHNICAL</strong> UPDATE<br />

Date: 25/07/2008 Sheet 2 of 24<br />

Indoor Unit<br />

OPTIONAL EXTRAS - ENERGY SAVING<br />

Electronically<br />

Commutated (EC) Fan<br />

Motor<br />

Sizes 6 - 60<br />

Backward curved impellers, direct drive centrifugal fan assemblies with integral<br />

rotor mounted motor which is statically and dynamically balanced for<br />

quiet operation.<br />

Designed for high corrosion resistance, the impellers are laser welded<br />

aluminium with a galvanised rotor and die cast aluminium EC power module.<br />

EC motors incorporate integrated electronics to convert AC power to DC for<br />

efficient and accurate speed control and are adjustable via the microprocessor<br />

display keypad.<br />

The fans offer maximum airflow performance while keeping sound levels to<br />

a minimum.<br />

The fans are mounted within a floorstand complete with adjustable feet, optional<br />

legs and floor tile lip. Height of the floorstand; please specify at order.<br />

EC motors are DC motors with integrated AC to DC conversion; this gives the<br />

flexibility of connecting to AC mains with the efficiency and simple speed control<br />

of a DC motor. The EC fan offers significant power reduction in comparison with<br />

equivalent AC fan at both full and modulated fan speeds. The inbuilt EC fan<br />

control module allows for fan speed modulation from 15-100%, a standard AC<br />

fans modulating range is typically 40-100% of full fan speed.<br />

The EC fan presents superior energy efficiency at full and reduced fan speed<br />

compared to the equivalent AC fan motor.<br />

Standard voltage regulated (VR) fan speed controllers offer a linear response.<br />

By comparison the EC fan is adjusted on demand via the unit microprocessor<br />

with precision, offering substantial energy savings. The following illustration<br />

shows a comparison of the typical power input required by each method.<br />

Input Power<br />

Airflow<br />

Key<br />

EC (Electronically<br />

Commutated) Fan Speed<br />

Control<br />

Voltage Regulated (VR) Fan<br />

Speed Control<br />

Energy Manager Analysis of system energy consumption can be monitored via a dedicated LCD<br />

display. Unit parameters can be adjusted via the unit microprocessor control to<br />

affect energy usage in line with the system need.<br />

CAUTION<br />

If Phase Rotation Protection and an Energy Manager unit are both<br />

required, the Energy Manager will require the addition of a Field Card,<br />

please contact Airedale.


<strong>TECHNICAL</strong> UPDATE<br />

Date: 25/07/2008 Sheet 3 of 24<br />

DIMENSIONS<br />

<strong>DF</strong>6 - <strong>DF</strong>26 - Standard Airflow Configuration (mm) with Standard AC Fan Motors<br />

670<br />

640<br />

15<br />

1940<br />

270<br />

200<br />

C<br />

6 - 10 13 - 17 20 - 26<br />

670 990 1310<br />

D<br />

B<br />

A<br />

F<br />

G<br />

200<br />

15<br />

C<br />

D<br />

B<br />

A<br />

7<br />

C D E D<br />

6<br />

4<br />

B B<br />

A<br />

5<br />

1 2<br />

H x D x W A B C<br />

(8)<br />

D (8)<br />

E F (9) G (8)<br />

<strong>DF</strong>6 X/WX/CW mm 1940 x 670 x 670 640 270 216 (183) 238 (304) N/A 50 (157) 268 (268)<br />

<strong>DF</strong>8 X/WX/CW mm 1940 x 670 x 670 640 270 183 (167) 304 (337) N/A 50 (157) 268 (295)<br />

<strong>DF</strong>10 X/WX/CW mm 1940 x 670 x 670 640 270 167 (N/A) 337 (N/A) N/A 50 (186) 295 (N/A)<br />

<strong>DF</strong>13 X/WX/CW mm 1940 x 670 x 990 960 590 326 (N/A) 337 (N/A) N/A 50 (186) 295 (N/A)<br />

<strong>DF</strong>15 X/WX/CW mm 1940 x 670 x 990 960 590 294 (N/A) 401 (N/A) N/A 50 (210) 347 (N/A)<br />

<strong>DF</strong>17 X/WX/CW mm 1940 x 670 x 990 960 590 294 (N/A) 401 (N/A) N/A 50 (210) 347 (N/A)<br />

<strong>DF</strong>20 X2/WX2/CW mm 1940 x 670 x 1310 1280 455 166 (N/A) 337 (N/A) 303 50 (186) 295 (N/A)<br />

<strong>DF</strong>22 X2/WX2/CW mm 1940 x 670 x 1310 1280 455 166 (N/A) 337 (N/A) 303 50 (186) 295 (N/A)<br />

<strong>DF</strong>26 X2/WX2/CW mm 1940 x 670 x 1310 1280 455 166 (N/A) 337 (N/A) 303 50 (186) 295 (N/A)<br />

(1) Standard forward airflow direction.<br />

(2) Optional reverse airflow direction.<br />

(3) Optional gland plate and panel for side services access via the right side of unit. For services details contact Airedale.<br />

(4) Base mains cable entry.<br />

(5) Standard base gland plate entry for refrigeration/water services. For services details contact Airedale.<br />

(6) Shaded area denotes AC fan discharge aperture. Optional EC fan motor discharge aperture provided with protective mesh, not shown.<br />

(7) M6 fixing hole positions.<br />

(8) Figures in brackets represent position of fan discharge aperture when larger AC fan motor option is fitted.<br />

(9) Figures in brackets represent optional reverse air discharge configuration when fitted with standard AC fan motors.<br />

(10) Units fitted with optional EC fan motors require a floorstand; refer to Dimensions, on page 5.<br />

3


<strong>TECHNICAL</strong> UPDATE<br />

Date: 25/07/2008 Sheet 4 of 24<br />

DIMENSIONS<br />

<strong>DF</strong>28 - <strong>DF</strong>60 - Standard Airflow Configuration (mm) with Standard AC Fan Motors<br />

750<br />

1940<br />

710<br />

330<br />

20<br />

210<br />

28 - 31<br />

C<br />

1460<br />

D<br />

B B B<br />

A<br />

F<br />

G<br />

210<br />

20<br />

35 - 45<br />

C<br />

1835<br />

D<br />

B B B<br />

A<br />

7<br />

6<br />

C<br />

4<br />

50 - 60<br />

D<br />

E<br />

2170<br />

B B B B<br />

A<br />

D<br />

5<br />

3<br />

1 2<br />

H x D x W A B C<br />

(8)<br />

D (8)<br />

E F (9)<br />

G (8)<br />

<strong>DF</strong>28 X/WX/CW mm 1940 x 750 x 1460 1420 347 540 379 N/A 91 (113) 546<br />

<strong>DF</strong>31 X/WX/CW mm 1940 x 750 x 1460 1420 347 540 379 N/A 91 (113) 546<br />

<strong>DF</strong>35 X/WX/CW mm 1940 x 750 x 1835 1795 472 679 477 N/A 91 (113) 546<br />

<strong>DF</strong>40 X/WX/CW mm 1940 x 750 x 1835 1795 472 679 477 N/A 91 (113) 546<br />

<strong>DF</strong>45 X/WX/CW mm 1940 x 750 x 1835 1795 472 679 477 N/A 91 (113) 546<br />

<strong>DF</strong>50 X2/WX2/CW mm 1940 x 750 x 2170 2130 438 206 401 543 76 (257) 345<br />

<strong>DF</strong>55 X2/WX2/CW mm 1940 x 750 x 2170 2130 438 206 401 543 76 (257) 345<br />

<strong>DF</strong>60 X2/WX2/CW mm 1940 x 750 x 2170 2130 438 206 401 543 76 (257) 345<br />

(1) Standard forward airflow direction.<br />

(2) Optional reverse airflow direction.<br />

(3) Optional gland plate and panel for side services access via the right side of unit. For services details contact Airedale.<br />

(4) Base mains cable entry.<br />

(5) Standard base gland plate entry for refrigeration/water services. For services details contact Airedale.<br />

(6) Shaded area denotes AC fan discharge aperture. Optional EC fan motor discharge aperture provided with protective mesh, not shown.<br />

(7) M6 fixing hole positions.<br />

(8) Figures in brackets represent position of fan discharge aperture when larger AC fan motor option is fitted.<br />

(9) Figures in brackets represent optional reverse air discharge configuration when fitted with standard AC fan motors.<br />

(10) Units fitted with optional EC fan motors require a floorstand; refer to Dimensions, on page 5.


<strong>TECHNICAL</strong> UPDATE<br />

Date: 25/07/2008 Sheet 5 of 24<br />

POSITIONING<br />

Standard Return and AC Fan Motors Standard Return and Optional EC Fan Motors<br />

MINIMUM UNIT CLEARANCE<br />

Open & Enclosed Floorstands Option<br />

A B C - Floorstand (3) D (4)<br />

<strong>DF</strong>6 - <strong>DF</strong>10 mm 670 610 Min 200 - Max 750<br />

Min 300<br />

<strong>DF</strong>13 - <strong>DF</strong>17 mm 990 610 (+ 50mm Feet<br />

Min 300<br />

<strong>DF</strong>20 - <strong>DF</strong>26 mm 1310 610<br />

Adjustable +/- 20mm) Min 300<br />

<strong>DF</strong>28 - <strong>DF</strong>31 mm 1460 700 Min 300 - Max 800<br />

Min 300<br />

<strong>DF</strong>35 - <strong>DF</strong>45 mm 1835 700 (+ 50mm Feet<br />

Min 300<br />

<strong>DF</strong>50 - <strong>DF</strong>60 mm 2170 700<br />

Adjustable +/- 20mm) Min 300<br />

EC Fan Motor Option<br />

C (3)<br />

With Feet Only (4) With Leg & Feet (4)<br />

A B Min Max Min Max D (5)<br />

<strong>DF</strong>6 - <strong>DF</strong>10 mm 670 610 284 329 604 1074 Min 300<br />

<strong>DF</strong>13 - <strong>DF</strong>17 mm 990 610 362 407 697 1152 Min 300<br />

<strong>DF</strong>20 - <strong>DF</strong>26 mm 1310 610 362 407 697 1152 Min 300<br />

<strong>DF</strong>28 - <strong>DF</strong>31 mm 1460 700 356 401 686 1146 Min 300<br />

<strong>DF</strong>35 - <strong>DF</strong>45 mm 1835 700 356 401 686 1146 Min 300<br />

<strong>DF</strong>50 - <strong>DF</strong>60 mm 2170 700 356 401 686 1146 Min 300<br />

Minimum Ceiling Clearance<br />

E<br />

Forward Only Forward & 1 Side Forward & 2 Sides All Faces<br />

<strong>DF</strong>6 - <strong>DF</strong>10 mm 470 240 160 120<br />

<strong>DF</strong>13 - <strong>DF</strong>17 mm 550 330 240 170<br />

<strong>DF</strong>20 - <strong>DF</strong>26 mm 560 370 280 190<br />

<strong>DF</strong>28 - <strong>DF</strong>31 mm 620 410 310 210<br />

<strong>DF</strong>35 - <strong>DF</strong>45 mm 640 450 350 230<br />

<strong>DF</strong>50 - <strong>DF</strong>60 mm 640 480 380 240<br />

(1) Shown with optional open floor stand.<br />

(2) Shaded area indicates minimum service and maintenance requirements.<br />

(3) Dimension C denotes recommended minimum/maximum floorstand height, refer to Airedale for special applications, please specify at order.<br />

(4) Min = Threaded foot at minimum extension.<br />

Max = Threaded foot at maximum extension.<br />

(5) Dimension D refers to units fitted with LPHW which require access to the RHS of the unit to set up the regulating valve.<br />

(6) SERVICES SIDE ACCESS GLAND PLATE, OPTIONAL POSITION; ensure appropriate clearance is available to the base of the RHS of the<br />

unit if this option is selected.


<strong>TECHNICAL</strong> UPDATE<br />

Date: 25/07/2008 Sheet 6 of 24<br />

WEIGHTS<br />

Standard Evaporator Fan - AC Motor (1) Optional Evaporator Fan - EC Motor (2)<br />

Machine (AHU) (3) Operating (AHU) Machine (AHU) (3) Operating (AHU) Floorstand<br />

<strong>DF</strong>6X kg 193 - 184 - 26<br />

<strong>DF</strong>8X kg 201 - 187 - 26<br />

<strong>DF</strong>10X kg 206 - 189 - 26<br />

<strong>DF</strong>13X kg 226 - 210 - 29<br />

<strong>DF</strong>15X kg 237 - 213 - 29<br />

<strong>DF</strong>17X kg 238 - 214 - 29<br />

<strong>DF</strong>20X2 kg 307 - 271 - 44<br />

<strong>DF</strong>22X2 kg 307 - 271 - 44<br />

<strong>DF</strong>26X2 kg 311 - 275 - 44<br />

<strong>DF</strong>28X kg 414 - 380 - 125<br />

<strong>DF</strong>31X kg 419 - 375 - 125<br />

<strong>DF</strong>35X kg 477 - 430 - 128<br />

<strong>DF</strong>40X kg 500 - 439 - 128<br />

<strong>DF</strong>45X kg 553 - 492 - 128<br />

<strong>DF</strong>50X2 kg 621 - 562 - 190<br />

<strong>DF</strong>55X2 kg 638 - 579 - 190<br />

<strong>DF</strong>60X2 kg 638 - 573 - 190<br />

<strong>DF</strong>6WX kg 209 211 200 202 26<br />

<strong>DF</strong>8WX kg 221 222 207 208 26<br />

<strong>DF</strong>10WX kg 225 226 208 209 26<br />

<strong>DF</strong>13WX kg 249 250 233 234 29<br />

<strong>DF</strong>15WX kg 267 269 243 245 29<br />

<strong>DF</strong>17WX kg 271 273 247 249 29<br />

<strong>DF</strong>20WX2 kg 348 350 312 314 44<br />

<strong>DF</strong>22WX2 kg 348 350 312 314 44<br />

<strong>DF</strong>26WX2 kg 351 354 315 318 44<br />

<strong>DF</strong>28WX kg 470 476 436 442 125<br />

<strong>DF</strong>31WX kg 475 481 431 437 125<br />

<strong>DF</strong>35WX kg 537 543 490 496 128<br />

<strong>DF</strong>40WX kg 565 571 504 510 128<br />

<strong>DF</strong>45WX kg 640 650 579 589 128<br />

<strong>DF</strong>50WX2 kg 712 722 653 663 190<br />

<strong>DF</strong>55WX2 kg 731 741 672 682 190<br />

<strong>DF</strong>60WX2 kg 731 741 666 676 190<br />

<strong>DF</strong>6CW kg 155 - 146 - 26<br />

<strong>DF</strong>8CW kg 165 - 151 - 26<br />

<strong>DF</strong>10CW kg 168 - 151 - 26<br />

<strong>DF</strong>13CW kg 195 - 179 - 29<br />

<strong>DF</strong>15CW kg 200 - 176 - 29<br />

<strong>DF</strong>17CW kg 200 - 176 - 29<br />

<strong>DF</strong>20CW kg 252 - 216 - 44<br />

<strong>DF</strong>22CW kg 252 - 216 - 44<br />

<strong>DF</strong>26CW kg 252 - 216 - 44<br />

<strong>DF</strong>28CW kg 351 - 317 - 125<br />

<strong>DF</strong>31CW kg 354 - 310 - 125<br />

<strong>DF</strong>35CW kg 410 - 363 - 128<br />

<strong>DF</strong>40CW kg 431 - 370 - 128<br />

<strong>DF</strong>45CW kg 442 - 381 - 128<br />

<strong>DF</strong>50CW kg 486 - 427 - 190<br />

<strong>DF</strong>55CW kg 499 - 440 - 190<br />

<strong>DF</strong>60CW kg 495 - 430 - 190<br />

(1) Weights quoted for units fitted with the standard AC fan motor include the cooling fan weight within the unit cabinet (AHU).<br />

(2) Weights quoted for units fitted with the optional EC fan motor exclude the cooling fan weight within the unit cabinet (AHU).<br />

(3) Machine weight includes a refrigerant charge / Operating weight includes calculated water volume, refer to Mechanical Data, on page 7.<br />

SOUND DATA<br />

IMPORTANT<br />

The sound data quoted is based on the unit having the STANDARD AC FAN<br />

MOTOR, for sound data of the OPTIONAL EC FAN MOTOR, please contact Airedale.


<strong>TECHNICAL</strong> UPDATE<br />

Date: 25/07/2008 Sheet 7 of 24<br />

MECHANICAL DATA - AIR & WATER COOLED MODELS<br />

<strong>DF</strong>6X-EZR <strong>DF</strong>8X-EZR <strong>DF</strong>10X-EZR <strong>DF</strong>13X-EZR<br />

<strong>DF</strong>6WX-EZR <strong>DF</strong>8WX-EZR <strong>DF</strong>10WX-EZR <strong>DF</strong>13WX-EZR<br />

Standard Condenser Match - X<br />

Capacity<br />

CR12 CR16 CR16 CR22<br />

Nom Cooling (Gross) - X (1) kW 6.1 7.9 10.1 13.3<br />

Nom Cooling (Gross) - WX (2) kW 6.1 7.9 10.2 13.4<br />

Total Heat of Rejection - WX (2) kW 8.2 10.2 13.5 17.9<br />

Capacity Steps 1 1 1 1<br />

Fan Gain kW 1 x 0.33 1 x 0.60 1 x 0.65 1 x 0.65<br />

Dimensions - H x D x W mm 1940 x 670 x 670 1940 x 670 x 670 1940 x 670 x 670 1940 x 670 x 990<br />

Weight - Machine - X (3) kg 193 201 206 226<br />

Weight - Machine / Operating - WX (3) kg 209 / 211 221 / 222 225 / 226 249 / 250<br />

Construction<br />

Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Light Grey, (RAL 7035) / Frame: Anodised<br />

Material/Colour<br />

Aluminium Frame with Black Nylon Corners<br />

Evaporator Rifled Copper Tube/Turbulated Hydrophilic Coated Aluminium Fins<br />

Cooling/Dehum Stages 1/1 1/1 1/1 1/1<br />

Condenser - WX Stainless Steel Brazed Plate<br />

Water Volume l 1.1 1.4 1.4 1.4<br />

Evaporator Fan Motor - AC Motor Centrifugal Forward Curved Direct Drive - Designed to 25Pa ESP<br />

Quantity x Motor Size (4) kW 1 x 0.30 1 x 0.55 1 x 0.60 1 x 0.60<br />

Maximum ESP Pa 196 140 118 294<br />

Nominal Airflow m³/s 0.55 0.75 0.95 1.00<br />

Compressor - Scroll Single<br />

Quantity 1 1 1 1<br />

Oil Charge Volume (Total) l 1.10 1.25 1.25 1.24<br />

Oil Type Polyol Ester<br />

Refrigeration Single Circuit<br />

Refrigeration Control & Type (5) Thermostatic Expansion Valve (Optional EEV) / R410A<br />

Holding Charge - X Inert Gas<br />

Charge (Total) - WX<br />

Connections<br />

kg 1.4 1.6 1.6 2.1<br />

Liquid (Sweat) - X in 3/8 3/8 3/8 3/8<br />

Discharge (Sweat) - X in 1/2 1/2 1/2 5/8<br />

Water Inlet / Outlet - WX mm 22 22 22 22<br />

Condensate Drain Hose mm 19 19 19 19<br />

Filtration Disposable to BS EN 779 - G4 - 50mm<br />

Quantity<br />

OPTIONAL EXTRAS<br />

1 1 1 2<br />

Larger Condenser Match - X CR16 CR22 CR22 CR30<br />

Nom Cooling (Gross)<br />

Hot Gas Reheat - X<br />

(1) kW 6.1 7.9 10.2 13.4<br />

Nom Heating (Gross) (6) kW 4.2 4.8 5.3 7.4<br />

Electric Heating (Total)<br />

Humidifier<br />

kW 7.5 7.5 7.5 7.5<br />

Capacity kg/hr 0.6 - 3.0 0.6 - 3.0 0.6 - 3.0 0.6 - 3.0<br />

Feed/Drain<br />

Condensate Pump<br />

3/4” BSPF Braided flexible hose / 19mm hose connection<br />

Head m 8 8 8 8<br />

Flow l/m 5 5 5 5<br />

Drain<br />

Evaporator Fan Options:<br />

10mm S/Steel Stub Connection<br />

Larger Fan Motor - AC Motor Centrifugal Forward Curved Direct Drive - Designed to 25Pa ESP<br />

Quantity x Motor Size (4) kW 1 x 0.55 1 x 0.60 N/A N/A<br />

Maximum ESP Pa 254 253 N/A N/A<br />

Fan Gain kW 1 x 0.60 1 x 0.65 N/A N/A<br />

Standard Fan Motor - EC Motor Centrifugal Backward Curved Direct Drive - Designed to 25Pa ESP<br />

Quantity x Motor Size (4) kW 1 x 0.94 1 x 0.94 1 x 0.94 1 x 1.01<br />

Speed @ 25Pa / Maximum ESP rpm 1335 / 2215 1705 / 2215 2145 / 2215 1105 / 1560<br />

Maximum ESP Pa 475 295 50 310<br />

Fan Gain rpm 1 x 0.32 1 x 0.32 1 x 0.32 1 x 0.35<br />

Low Pressure Hot Water Copper Tube/Aluminium Fin<br />

Capacity Gross (7) kW 6.50 7.50 8.40 11.50<br />

Water Flow (Nominal) l/s 0.14 0.17 0.19 0.26<br />

LPHW Connection Sizes<br />

Threaded Connection - WX<br />

mm 22 22 22 22<br />

Brass Male Taper in 3/4 3/4 3/4 3/4<br />

(1) Entering air 24°C/45% RH ambient 35°C.<br />

(2) Entering air 24°C/45% RH condenser water in / out: 30°C/35°C.<br />

(3) With Standard AC fan motors; Machine weight includes a refrigerant charge / Operating weight includes calculated water volume. Refer to Weights, on page 6<br />

for units with Optional EC fan motors.<br />

(4) AC fan motors: motor size relates to the shaft power. EC fan motors: motor size relates to the absorbed electrical power.<br />

(5) For refrigerant charges, refer to Unit Refrigerant Charge (kg/Circuit), page 44 in main manual.<br />

(6) Based on air temperature of 15.5°C leaving the evaporator coil.<br />

(7) Based upon low pressure hot water 82°C inlet/71°C outlet. Air on 20°C. Refer to Low Pressure Hot Water (Optional Extra) - X & WX Models, page 41 in<br />

main manual.


<strong>TECHNICAL</strong> UPDATE<br />

Date: 25/07/2008 Sheet 8 of 24<br />

MECHANICAL DATA - AIR & WATER COOLED MODELS<br />

<strong>DF</strong>15X-EZR <strong>DF</strong>17X-EZR <strong>DF</strong>20X2-EZR <strong>DF</strong>22X2-EZR <strong>DF</strong>26X2-EZR<br />

<strong>DF</strong>15WX-EZR <strong>DF</strong>17WX-EZR <strong>DF</strong>20WX2-EZR <strong>DF</strong>22WX2-EZR <strong>DF</strong>26WX2-EZR<br />

Standard Condenser Match - X<br />

Capacity<br />

CR22 CR30 CR30 CR50 CR50<br />

Nom Cooling (Gross) - X (1) kW 14.9 17.2 20.2 21.5 26.3<br />

Nom Cooling (Gross) - WX (2) kW 15.2 17.4 20.8 21.5 26.3<br />

Total Heat of Rejection - WX (2) kW 20.1 23.1 27.5 28.2 35.2<br />

Capacity Steps 1 1 2 2 2<br />

Fan Gain kW 1 x 1.20 1 x 1.20 2 x 0.65 2 x 0.65 2 x 0.65<br />

Dimensions - H x D x W mm 1940 x 670 x 990 1940 x 670 x 990 1940 x 670 x 1310 1940 x 670 x 1310 1940 x 670 x 1310<br />

Weight - Machine - X (3) kg 237 238 307 307 311<br />

Weight - Machine / Operating - WX (3) kg 267 / 269 271 / 273 348 / 350 348 / 350 351 / 354<br />

Construction<br />

Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Light Grey, (RAL 7035) / Frame: Anodised<br />

Material/Colour<br />

Aluminium Frame with Black Nylon Corners<br />

Evaporator Rifled Copper Tube/Turbulated Hydrophilic Coated Aluminium Fins<br />

Cooling/Dehum Stages 1/1 1/1 2/1 2/1 2/1<br />

Condenser - WX Stainless Steel Brazed Plate<br />

Water Volume l 2.0 2.5 2.5 2.5 2.5<br />

Evaporator Fan Motor - AC Motor Centrifugal Forward Curved Direct Drive - Designed to 25Pa ESP<br />

Quantity x Motor Size (4) kW 1 x 1.10 1 x 1.10 2 x 0.60 2 x 0.60 2 x 0.60<br />

Maximum ESP Pa 120 34 194 43 43<br />

Nominal Airflow m³/s 1.20 1.40 1.70 2.00 2.00<br />

Compressor - Scroll Single Tandem<br />

Quantity 1 1 2 2 2<br />

Oil Charge Volume (Total) l 1.66 1.89 2.50 2.50 2.48<br />

Oil Type Polyol Ester<br />

Refrigeration Single Circuit<br />

Refrigeration Control & Type (5) Thermostatic Expansion Valve (Optional EEV) / R410A<br />

Holding Charge - X Inert Gas<br />

Charge (Total) - WX<br />

Connections<br />

kg 2.6 2.6 3.2 3.2 3.2<br />

Liquid (Sweat) - X in 3/8 3/8 1/2 1/2 1/2<br />

Discharge (Sweat) - X in 5/8 5/8 7/8 7/8 7/8<br />

Water Inlet / Outlet - WX mm 22 28 28 28 28<br />

Condensate Drain Hose mm 19 19 19 19 19<br />

Filtration Disposable to BS EN 779 - G4 - 50mm<br />

Quantity<br />

OPTIONAL EXTRAS<br />

2 2 3 3 3<br />

Larger Condenser Match - X CR30 CR50 CR50 CR65 CR65<br />

Nom Cooling (Gross)<br />

Hot Gas Reheat - X<br />

(1) kW 15.2 17.4 20.8 21.5 26.3<br />

Nom Heating (Gross) (6) kW 8.1 8.6 9.0 9.6 9.6<br />

Electric Heating (Total)<br />

Humidifier<br />

kW 7.5 7.5 15.0 15.0 15.0<br />

Capacity kg/hr 0.6 - 3.0 0.6 - 3.0 0.6 - 3.0 0.6 - 3.0 0.6 - 3.0<br />

Feed/Drain<br />

Condensate Pump<br />

3/4” BSPF Braided flexible hose / 19mm hose connection<br />

Head m 8 8 8 8 8<br />

Flow l/m 5 5 5 5 5<br />

Drain<br />

Evaporator Fan Options:<br />

10mm S/Steel Stub Connection<br />

Larger Fan Motor - AC Motor Centrifugal Forward Curved Direct Drive - Designed to 25Pa ESP<br />

Quantity x Motor Size (4) kW N/A N/A N/A N/A N/A<br />

Maximum ESP Pa N/A N/A N/A N/A N/A<br />

Fan Gain kW N/A N/A N/A N/A N/A<br />

Standard Fan Motor - EC Motor Centrifugal Backward Curved Direct Drive - Designed to 25Pa ESP<br />

Quantity x Motor Size (4) kW 1 x 1.01 1 x 1.01 1 x 2.63 1 x 2.63 1 x 2.63<br />

Speed @ 25Pa / Maximum ESP rpm 1310 / 1560 1515 / 1560 1745 / 2165 2055 / 2165 2055 / 2165<br />

Maximum ESP Pa 195 45 450 145 145<br />

Fan Gain rpm 1 x 0.35 1 x 0.35 1 x 0.91 1 x 0.91 1 x 0.91<br />

Low Pressure Hot Water Copper Tube/Aluminium Fin<br />

Capacity Gross (7) kW 12.50 13.30 16.10 16.60 16.60<br />

Water Flow (Nominal) l/s 0.28 0.30 0.36 0.37 0.37<br />

LPHW Connection Sizes<br />

Threaded Connection - WX<br />

mm 22 22 22 22 22<br />

Brass Male Taper in 3/4 1 1 1 1<br />

(1) Entering air 24°C/45% RH ambient 35°C.<br />

(2) Entering air 24°C/45% RH condenser water in / out: 30°C/35°C.<br />

(3) With Standard AC fan motors; Machine weight includes a refrigerant charge / Operating weight includes calculated water volume. Refer to Weights, on page 6<br />

for units with Optional EC fan motors.<br />

(4) AC fan motors: motor size relates to the shaft power. EC fan motors: motor size relates to the absorbed electrical power.<br />

(5) For refrigerant charges, refer to Unit Refrigerant Charge (kg/Circuit), page 44 in main manual.<br />

(6) Based on air temperature of 15.5°C leaving the evaporator coil.<br />

(7) Based upon low pressure hot water 82°C inlet/71°C outlet. Air on 20°C. Refer to Low Pressure Hot Water (Optional Extra) - X & WX Models, page 41 in<br />

main manual.


<strong>TECHNICAL</strong> UPDATE<br />

Date: 25/07/2008 Sheet 9 of 24<br />

MECHANICAL DATA - AIR & WATER COOLED MODELS<br />

<strong>DF</strong>28X-EZR <strong>DF</strong>31X-EZR <strong>DF</strong>35X-EZR <strong>DF</strong>40X-EZR<br />

<strong>DF</strong>28WX-EZR <strong>DF</strong>31WX-EZR <strong>DF</strong>35WX-EZR <strong>DF</strong>40WX-EZR<br />

Standard Condenser Match - X<br />

Capacity<br />

CR50 CR50 CR50 CR65<br />

Nom Cooling (Gross) - X (1) kW 25.5 28.9 33.1 37.5<br />

Nom Cooling (Gross) - WX (2) kW 25.5 29.1 33.8 37.7<br />

Total Heat of Rejection - WX (2) kW 34.3 39.0 45.2 50.4<br />

Capacity Steps 1 1 1 1<br />

Fan Gain kW 1 x 1.43 1 x 2.60 1 x 2.60 1 x 3.58<br />

Dimensions - H x D x W mm 1940 x 750 x 1460 1940 x 750 x 1460 1940 x 750 x 1835 1940 x 750 x 1835<br />

Weight - Machine - X (3) kg 414 419 477 500<br />

Weight - Machine / Operating- WX (3) kg 470 / 476 475 / 481 537 / 543 565 / 571<br />

Construction<br />

Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Light Grey, (RAL 7035) / Frame: Anodised<br />

Material/Colour<br />

Aluminium Frame with Black Nylon Corners<br />

Evaporator Rifled Copper Tube/Turbulated Hydrophilic Coated Aluminium Fins<br />

Cooling/Dehum Stages 1/1 1/1 1/1 1/1<br />

Condenser - WX Stainless Steel Brazed Plate<br />

Water Volume l 6.1 6.1 6.1 6.1<br />

Evaporator Fan Motor - AC Motor Centrifugal Forward Curved Belt & Pulley - Designed to 25Pa ESP<br />

Quantity x Motor Size (4) kW 1 x 2.2 1 x 4.0 1 x 4.0 1 x 5.5<br />

Speed @ 25Pa / Maximum ESP rpm 871 / 909 1008 /1171 980 /1078 1094 / 1186<br />

Maximum ESP Pa 75 265 165 175<br />

Nominal Airflow m³/s 2.4 2.8 3.3 3.7<br />

Compressor - Scroll Single<br />

Quantity 1 1 1 1<br />

Oil Charge Volume (Total) l 3.30 3.30 3.30 3.30<br />

Oil Type Polyol Ester<br />

Refrigeration Single Circuit<br />

Refrigeration Control & Type (5) Thermostatic Expansion Valve (Optional EEV) / R410A<br />

Holding Charge - X Inert Gas<br />

Charge (Total) - WX<br />

Connections<br />

kg 5.3 5.3 6.0 6.0<br />

Liquid (Sweat) - X in 1/2 1/2 1/2 5/8<br />

Discharge (Sweat) - X in 7/8 7/8 7/8 1 1/8<br />

Water Inlet / Outlet - WX mm 35 35 35 35<br />

Condensate Drain Hose mm 19 19 19 19<br />

Filtration Disposable to BS EN 779 - G4 - 75mm<br />

Quantity<br />

OPTIONAL EXTRAS<br />

3 3 3 3<br />

Larger Condenser Match - X CR65 CR65 CR65 CR80<br />

Nom Cooling (Gross)<br />

Hot Gas Reheat - X<br />

(1) kW 25.5 29.1 33.8 37.7<br />

Nom Heating (Gross) (6) kW 12.7 13.5 19.4 20.3<br />

Electric Heating (Total)<br />

Humidifier<br />

kW 20.0 20.0 20.0 20.0<br />

Capacity kg/hr 1.6 - 8.0 1.6 - 8.0 3.0 - 15.0 3.0 - 15.0<br />

Feed/Drain<br />

Condensate Pump<br />

3/4” BSPF Braided flexible hose / 19mm hose connection<br />

Head m 10.8 10.8 10.8 10.8<br />

Flow l/m 5 5 5 5<br />

Drain<br />

Evaporator Fan Options:<br />

10mm S/Steel Stub Connection<br />

Larger Fan Motor - AC Motor Centrifugal Forward Curved Belt & Pulley - Designed to 25Pa ESP<br />

Quantity x Motor Size (4) kW 1 x 3.00 / 1 x 4.0 N/A 1 x 5.50 N/A<br />

Speed @ Maximum ESP rpm 1144 / 1439 N/A 1196 N/A<br />

Maximum ESP Pa 362 / 722 N/A 322 N/A<br />

Fan Gain kW 1 x 1.95 / 1 x 2.6 N/A 1 x 3.58 N/A<br />

Standard Fan Motor - EC Motor Centrifugal Backward Curved Direct Drive - Designed to 25Pa ESP<br />

Quantity x Motor Size (4) kW 2 x 2.63 2 x 2.63 2 x 2.63 2 x 2.63<br />

Speed @ 25Pa / Maximum ESP rpm 1570 / 2165 1775 / 2165 1895 / 2165 2135 / 2165<br />

Maximum ESP Pa 595 390 285 70<br />

Fan Gain rpm 2 x 1.83 2 x 1.83 2 x 1.83 2 x 1.83<br />

Low Pressure Hot Water Copper Tube/Aluminium Fin<br />

Capacity Gross (7) kW 21.30 22.70 30.00 31.50<br />

Water Flow (Nominal) l/s 0.48 0.51 0.67 0.70<br />

LPHW Connection Sizes<br />

Threaded Connection - WX<br />

mm 22 22 22 22<br />

Brass Male Taper in 1 1/4 1 1/4 1 1/4 1 1/4<br />

(1) Entering air 24°C/45% RH ambient 35°C.<br />

(2) Entering air 24°C/45% RH condenser water in / out: 30°C/35°C.<br />

(3) With Standard AC fan motors; Machine weight includes a refrigerant charge / Operating weight includes calculated water volume. Refer to Weights, on page 6<br />

for units with Optional EC fan motors.<br />

(4) AC fan motors: motor size relates to the shaft power. EC fan motors: motor size relates to the absorbed electrical power.<br />

(5) For refrigerant charges, refer to Unit Refrigerant Charge (kg/Circuit), page 44 in main manual.<br />

(6) Based on air temperature of 15.5°C leaving the evaporator coil.<br />

(7) Based upon low pressure hot water 82°C inlet/71°C outlet. Air on 20°C. Refer to Low Pressure Hot Water (Optional Extra) - X & WX Models, page 41 in<br />

main manual.


<strong>TECHNICAL</strong> UPDATE<br />

Date: 25/07/2008 Sheet 10 of 24<br />

MECHANICAL DATA - AIR & WATER COOLED MODELS<br />

<strong>DF</strong>45X-EZR <strong>DF</strong>50X2-EZR <strong>DF</strong>55X2-EZR <strong>DF</strong>60X2-EZR<br />

<strong>DF</strong>45WX-EZR <strong>DF</strong>50WX2-EZR <strong>DF</strong>55WX2-EZR <strong>DF</strong>60WX2-EZR<br />

Standard Condenser Match - X<br />

Capacity<br />

CR80 CR80 CR80 CR80<br />

Nom Cooling (Gross) - X (1) kW 42.5 49.1 54.8 61.0<br />

Nom Cooling (Gross) - WX (2) kW 42.5 49.5 56.0 63.1<br />

Total Heat of Rejection - WX (2) kW 56.7 67.0 75.7 85.7<br />

Capacity Steps 1 2 2 2<br />

Fan Gain kW 1 x 3.58 2 x 1.43 2 x 1.43 2 x 1.95<br />

Dimensions - H x D x W mm 1940 x 750 x 1835 1940 x 750 x 2170 1940 x 750 x 2170 1940 x 750 x 2170<br />

Weight - Machine - X (3) kg 553 621 638 638<br />

Weight - Machine / Operating - WX (3) kg 640 / 650 712 / 722 731 / 741 731 / 741<br />

Construction<br />

Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Light Grey, (RAL 7035) / Frame: Anodised<br />

Material/Colour<br />

Aluminium Frame with Black Nylon Corners<br />

Evaporator Rifled Copper Tube/Turbulated Hydrophilic Coated Aluminium Fins<br />

Cooling/Dehum Stages 1/1 2/1 2/1 2/1<br />

Condenser - WX Stainless Steel Brazed Plate<br />

Water Volume l 9.9 9.9 9.9 9.9<br />

Evaporator Fan Motor - AC Motor Centrifugal Forward Curved Belt & Pulley - Designed to 25Pa ESP<br />

Quantity x Motor Size (4) kW 1 x 5.5 2 x 2.2 2 x 2.2 2 x 3.0<br />

Speed @ 25Pa / Maximum ESP rpm 1094 / 1186 1167 / 1170 1167 / 1170 1307 / 1311<br />

Maximum ESP Pa 175 35 35 75<br />

Nominal Airflow m³/s 3.7 4.2 4.2 4.6<br />

Compressor - Scroll Single Tandem<br />

Quantity 1 2 2 2<br />

Oil Charge Volume (Total) l 6.7 6.6 6.6 6.6<br />

Oil Type Polyol Ester<br />

Refrigeration Single Circuit<br />

Refrigeration Control & Type (5) Thermostatic Expansion Valve (Optional EEV) / R410A<br />

Holding Charge - X Inert Gas<br />

Charge (Total) - WX<br />

Connections<br />

kg 8.7 9.0 9.7 9.8<br />

Liquid (Sweat) - X in 5/8 5/8 5/8 5/8<br />

Discharge (Sweat) - X in 1 1/8 1 3/8 1 3/8 1 3/8<br />

Water Inlet / Outlet - WX mm 42 42 42 42<br />

Condensate Drain Hose mm 19 19 19 19<br />

Filtration Disposable to BS EN 779 - G4 - 75mm<br />

Quantity<br />

OPTIONAL EXTRAS<br />

3 4 4 4<br />

Larger Condenser Match - X CR105 CR105 CR105 CR105<br />

Nom Cooling (Gross)<br />

Hot Gas Reheat - X<br />

(1) kW 42.5 49.5 55.8 62.3<br />

Nom Heating (Gross) (6) kW 20.3 25.9 25.9 26.9<br />

Electric Heating (Total)<br />

Humidifier<br />

kW 20.0 30.0 30.0 30.0<br />

Capacity kg/hr 3.0 - 15.0 3.0 - 15.0 3.0 - 15.0 3.0 - 15.0<br />

Feed/Drain<br />

Condensate Pump<br />

3/4” BSPF Braided flexible hose / 19mm hose connection<br />

Head m 10.8 10.8 10.8 10.8<br />

Flow l/m 5 5 5 5<br />

Drain<br />

Evaporator Fan Options:<br />

10mm S/Steel Stub Connection<br />

Larger Fan Motor - AC Motor Centrifugal Forward Curved Belt & Pulley - Designed to 25Pa ESP<br />

Quantity x Motor Size (4) kW N/A 2 x 3.00 / 2 x 4.0 2 x 3.00 / 2 x 4.0 2 x 4.00<br />

Speed @ Maximum ESP rpm N/A 1448 / 1498 1448 / 1498 1497<br />

Maximum ESP Pa N/A 310 / 360 310 / 360 275<br />

Fan Gain kW N/A 2 x 1.95 / 2 x 2.6 2 x 1.95 / 2 x 2.6 2 x 2.60<br />

Standard Fan Motor - EC Motor Centrifugal Backward Curved Direct Drive - Designed to 25Pa ESP<br />

Quantity x Motor Size (4) kW 2 x 2.63 2 x 3.10 2 x 3.10 2 x 3.10<br />

Speed @ 25Pa / Maximum ESP rpm 2135 / 2165 1265 / 1510 1265 / 1510 1390 / 1510<br />

Maximum ESP Pa 70 320 320 185<br />

Fan Gain rpm 2 x 1.83 2 x 2.16 2 x 2.16 2 x 2.16<br />

Low Pressure Hot Water Copper Tube/Aluminium Fin<br />

Capacity Gross (7) kW 31.50 38.30 38.30 39.80<br />

Water Flow (Nominal) l/s 0.70 0.85 0.85 0.89<br />

LPHW Connection Sizes<br />

Threaded Connection - WX<br />

mm 22 22 22 22<br />

Brass Male Taper in 1 1/2 1 1/2 1 1/2 1 1/2<br />

(1) Entering air 24°C/45% RH ambient 35°C.<br />

(2) Entering air 24°C/45% RH condenser water in / out: 30°C/35°C.<br />

(3) With Standard AC fan motors; Machine weight includes a refrigerant charge / Operating weight includes calculated water volume. Refer to Weights, on page 6<br />

for units with Optional EC fan motors.<br />

(4) AC fan motors: motor size relates to the shaft power. EC fan motors: motor size relates to the absorbed electrical power.<br />

(5) For refrigerant charges, refer to Unit Refrigerant Charge (kg/Circuit), page 44 in main manual.<br />

(6) Based on air temperature of 15.5°C leaving the evaporator coil.<br />

(7) Based upon low pressure hot water 82°C inlet/71°C outlet. Air on 20°C. Refer to Low Pressure Hot Water (Optional Extra) - X & WX Models, page 41 in<br />

main manual.


<strong>TECHNICAL</strong> UPDATE<br />

Date: 25/07/2008 Sheet 11 of 24<br />

ELECTRICAL DATA - AIR & WATER COOLED MODELS<br />

<strong>DF</strong>6X-EZR <strong>DF</strong>8X-EZR <strong>DF</strong>10X-EZR <strong>DF</strong>13X-EZR<br />

<strong>DF</strong>6WX-EZR <strong>DF</strong>8WX-EZR <strong>DF</strong>10WX-EZR <strong>DF</strong>13WX-EZR<br />

Standard Condenser Match - X CR12 CR16 CR16 CR22<br />

Unit Data - X (1)<br />

Nominal Run Amps A 19.5 24.0 26.2 30.0<br />

Maximum Start Amps A 42.0 54.3 68.2 86.0<br />

Recommended Mains Fuse Size A 25 32 32 40<br />

Max Mains Incoming Cable Size mm² 6 6 6 35<br />

Mains Supply V 400V / 3PH + N / 50Hz<br />

Control circuit VAC 24 24 24 24<br />

Unit Data - WX (2)<br />

Nominal Run Amps A 18.4 22.9 25.1 27.1<br />

Maximum Start Amps A 40.9 53.2 67.1 83.1<br />

Recommended Mains Fuse Size A 25 32 32 32<br />

Max Mains Incoming Cable Size mm² 6 6 6 35<br />

Mains Supply V 400V / 3PH + N / 50Hz<br />

Control circuit VAC 24 24 24 24<br />

Evaporator Fan - AC Motor - Per Fan<br />

Quantity x Motor Size (3) kW 1 x 0.30 1 x 0.55 1 x 0.60 1 x 0.60<br />

Full Load Amps A 3.50 6.80 7.70 7.70<br />

Locked Rotor Amps A 8.75 17.00 20.50 20.50<br />

Compressor - Per Compressor<br />

Quantity x Motor Size kW 1 x 2.08 1 x 2.68 1 x 3.31 1 x 4.46<br />

Nominal Run Amps A 3.50 4.70 6.00 8.00<br />

Locked Rotor Amps A 26 35 48 64<br />

Type of Start Direct On Line<br />

Standard Condenser Match - AC Motor<br />

- Per Fan<br />

Quantity x Motor Size kW 1 x 0.24 1 x 0.24 1 x 0.24 1 x 0.63<br />

Full Load Amps A 1.10 1.10 1.10 2.90<br />

OPTIONAL EXTRAS<br />

Electric Heating<br />

Stage of Reheat 1 1 1 1<br />

Number of Elements 3 3 3 3<br />

Rating (Total) kW 7.5 7.5 7.5 7.5<br />

Current Per Phase A 10.9 10.9 10.9 10.9<br />

Humidifier<br />

Capacity kg/hr 0.60 - 3.00 0.60 - 3.00 0.60 - 3.00 0.60 - 3.00<br />

Rating kW 2.25 2.25 2.25 2.25<br />

Full Load Amps A 3.50 3.50 3.50 3.50<br />

Evaporator Fan Options:<br />

Larger Fan Motor - AC Motor - Per Fan<br />

Quantity x Motor Size (3) kW 1 x 0.55 1 x 0.60 N/A N/A<br />

Full Load Amps A 6.80 7.70 N/A N/A<br />

Locked Rotor Amps A 17.00 20.50 N/A N/A<br />

Standard Size Motor - EC Motor - Per Fan<br />

Quantity x Motor Size (3) kW 1 x 0.94 1 x 0.94 1 x 0.94 1 x 1.01<br />

Full Load Amps A 1.50 1.50 1.50 1.60<br />

Standard Condenser Match - EC Motor -<br />

Per Fan<br />

Quantity x Motor Size kW 1 x 0.7 1 x 0.7 1 x 0.7 1 x 0.77<br />

Full Load Amps A 3.1 3.1 3.1 3.30<br />

(1) Values given for full function units (incl. electric heating, humidification and matched condenser) at 7°C evaporating and 54.4°C condensing with<br />

standard fan AC motors, for optional data, please contact Airedale.<br />

(2) Values given for full function units (incl. electric heating and humidification) at 7°C evaporating and 54.4°C condensing with standard fan AC motors,<br />

for optional data, please contact Airedale.<br />

(3) AC fan motors: motor size relates to the shaft power. EC fan motors: motor size relates to the absorbed electrical power.


<strong>TECHNICAL</strong> UPDATE<br />

Date: 25/07/2008 Sheet 12 of 24<br />

ELECTRICAL DATA - AIR & WATER COOLED MODELS<br />

<strong>DF</strong>15X-EZR <strong>DF</strong>17X-EZR <strong>DF</strong>20X2-EZR <strong>DF</strong>22X2-EZR <strong>DF</strong>26X2-EZR<br />

<strong>DF</strong>15WX-EZR <strong>DF</strong>17WX-EZR <strong>DF</strong>20WX2-EZR <strong>DF</strong>22WX2-EZR <strong>DF</strong>26WX2-EZR<br />

Standard Condenser Match - X CR22 CR30 CR30 CR50 CR50<br />

Unit Data - X (1)<br />

Nominal Run Amps A 32.7 33.8 52.6 55.5 59.5<br />

Maximum Start Amps A 88.3 98.3 94.6 97.5 115.5<br />

Recommended Mains Fuse Size A 40 40 63 63 63<br />

Max Mains Incoming Cable Size mm² 35 35 35 35 35<br />

Mains Supply V 400V / 3PH + N / 50Hz<br />

Control circuit VAC 24 24 24 24 24<br />

Unit Data - WX (2)<br />

Nominal Run Amps A 29.8 30.9 49.7 49.7 53.7<br />

Maximum Start Amps A 85.4 95.4 91.7 91.7 109.7<br />

Recommended Mains Fuse Size A 40 40 63 63 63<br />

Max Mains Incoming Cable Size mm² 35 35 35 35 36<br />

Mains Supply V 400V / 3PH + N / 50Hz<br />

Control circuit VAC 24 24 24 24 24<br />

Evaporator Fan - AC Motor - Per Fan<br />

Quantity x Motor Size (3) kW 1 x 1.1 1 x 1.1 2 x 0.6 2 x 0.6 2 x 0.6<br />

Full Load Amps A 10.0 10.0 7.7 7.7 7.7<br />

Locked Rotor Amps A 25.0 25.0 20.5 20.5 20.5<br />

Compressor - Per Compressor<br />

Quantity x Motor Size kW 1 x 4.82 1 x 5.6 2 x 3.31 2 x 3.31 2 x 4.46<br />

Nominal Run Amps A 8.40 9.4 6.00 6.00 8.00<br />

Locked Rotor Amps A 64 74 48 48 64<br />

Type of Start Direct On Line<br />

Standard Condenser Match - AC Motor<br />

- Per Fan<br />

Quantity x Motor Size kW 1 x 0.63 1 x 0.63 1 x 0.63 2 x 0.63 2 x 0.63<br />

Full Load Amps A 2.90 2.90 2.90 2.90 2.90<br />

OPTIONAL EXTRAS<br />

Electric Heating<br />

Stage of Reheat 1 1 2 2 2<br />

Number of Elements 3 3 6 6 6<br />

Rating (Total) kW 7.5 7.5 15.0 15.0 15.0<br />

Current Per Phase A 10.9 10.9 21.8 21.8 21.8<br />

Humidifier<br />

Capacity kg/hr 0.60 - 3.00 0.60 - 3.00 0.60 - 3.00 0.60 - 3.00 0.60 - 3.00<br />

Rating kW 2.25 2.25 2.25 2.25 2.25<br />

Full Load Amps A 3.50 3.50 3.50 3.50 3.50<br />

Evaporator Fan Options:<br />

Larger Fan Motor - AC Motor - Per Fan<br />

Quantity x Motor Size (3) kW N/A N/A N/A N/A N/A<br />

Full Load Amps A N/A N/A N/A N/A N/A<br />

Locked Rotor Amps A N/A N/A N/A N/A N/A<br />

Standard Size Motor - EC Motor - Per Fan<br />

Quantity x Motor Size (3) kW 1 x 1.01 1 x 1.01 1 x 2.63 1 x 2.63 1 x 2.63<br />

Full Load Amps A 1.60 1.60 4.90 4.90 4.90<br />

Standard Condenser Match - EC Motor -<br />

Per Fan<br />

Quantity x Motor Size kW 1 x 0.77 1 x 0.77 1 x 0.77 2 x 0.77 2 x 0.77<br />

Full Load Amps A 3.30 3.30 3.30 3.30 3.30<br />

(1) Values given for full function units (incl. electric heating, humidification and matched condenser) at 7°C evaporating and 54.4°C condensing with<br />

standard fan AC motors, for optional data, please contact Airedale.<br />

(2) Values given for full function units (incl. electric heating and humidification) at 7°C evaporating and 54.4°C condensing with standard fan AC motors,<br />

for optional data, please contact Airedale.<br />

(3) AC fan motors: motor size relates to the shaft power. EC fan motors: motor size relates to the absorbed electrical power.


<strong>TECHNICAL</strong> UPDATE<br />

Date: 25/07/2008 Sheet 13 of 24<br />

ELECTRICAL DATA - AIR & WATER COOLED MODELS<br />

<strong>DF</strong>28X-EZR <strong>DF</strong>31X-EZR <strong>DF</strong>35X-EZR <strong>DF</strong>40X-EZR<br />

<strong>DF</strong>28WX-EZR <strong>DF</strong>31WX-EZR <strong>DF</strong>35WX-EZR <strong>DF</strong>40WX-EZR<br />

Standard Condenser Match - X CR50 CR50 CR50 CR65<br />

Unit Data - X (1)<br />

Nominal Run Amps A 58.7 64.1 66.6 70.6<br />

Maximum Start Amps A 199.7 177.2 210.2 207.9<br />

Recommended Mains Fuse Size A 63 80 80 80<br />

Max Mains Incoming Cable Size mm² 35 35 35 35<br />

Mains Supply V 400V / 3PH + N / 50Hz<br />

Control circuit VAC 24 24 24 24<br />

Unit Data - WX (2)<br />

Nominal Run Amps A 52.9 58.3 60.8 64.8<br />

Maximum Start Amps A 193.9 171.4 240.4 202.1<br />

Recommended Mains Fuse Size A 63 63 80 80<br />

Max Mains Incoming Cable Size mm² 35 35 35 35<br />

Mains Supply V 400V / 3PH + N / 50Hz<br />

Control circuit VAC 24 24 24 24<br />

Evaporator Fan - AC Motor - Per Fan<br />

Quantity x Motor Size (3) kW 1 x 2.2 1 x 4.0 1 x 4.0 1 x 5.5<br />

Full Load Amps A 4.7 8.2 8.2 10.9<br />

Locked Rotor Amps A 32.9 57.4 57.4 76.3<br />

Compressor - Per Compressor<br />

Quantity x Motor Size kW 1 x 8.47 1 x 9.46 1 x 10.86 1 x 12.15<br />

Nominal Run Amps A 15.00 16.90 19.40 20.70<br />

Locked Rotor Amps A 156 130 163 158<br />

Type of Start Direct On Line<br />

Standard Condenser Match - AC Motor<br />

- Per Fan<br />

Quantity x Motor Size kW 2 x 0.63 2 x 0.63 2 x 0.63 2 x 0.63<br />

Full Load Amps A 2.90 2.90 2.90 2.90<br />

OPTIONAL EXTRAS<br />

Electric Heating<br />

Stage of Reheat 3 3 3 3<br />

Number of Elements 8 8 8 8<br />

Rating (Total) kW 20 20 20 20.0<br />

Current Per Phase A 32.7 32.7 32.7 32.7<br />

Humidifier<br />

Capacity kg/hr 1.60 - 8.00 1.60 - 8.00 3.00 - 15.00 3.00 - 15.00<br />

Rating kW 6.00 6.00 11.25 11.25<br />

Full Load Amps A 8.70 8.70 15.80 15.80<br />

Evaporator Fan Options:<br />

Larger Fan Motor - AC Motor - Per Fan<br />

Quantity x Motor Size (3) kW 1 x 3.0 / 1 x 4.0 N/A 1 x 5.5 N/A<br />

Full Load Amps A 6.3 / 8.2 N/A 10.9 N/A<br />

Locked Rotor Amps A 44.1 / 57.4 N/A 76.3 N/A<br />

Standard Size Motor - EC Motor - Per Fan<br />

Quantity x Motor Size (3) kW 2 x 2.63 2 x 2.63 2 x 2.63 2 x 2.63<br />

Full Load Amps A 4.90 4.90 4.90 4.90<br />

Standard Condenser Match - EC Motor -<br />

Per Fan<br />

Quantity x Motor Size kW 2 x 0.77 2 x 0.77 2 x 0.77 2 x 0.77<br />

Full Load Amps A 3.30 3.30 3.30 3.30<br />

(1) Values given for full function units (incl. electric heating, humidification and matched condenser) at 7°C evaporating and 54.4°C condensing with<br />

standard fan AC motors, for optional data, please contact Airedale.<br />

(2) Values given for full function units (incl. electric heating and humidification) at 7°C evaporating and 54.4°C condensing with standard fan AC motors,<br />

for optional data, please contact Airedale.<br />

(3) AC fan motors: motor size relates to the shaft power. EC fan motors: motor size relates to the absorbed electrical power.


<strong>TECHNICAL</strong> UPDATE<br />

Date: 25/07/2008 Sheet 14 of 24<br />

ELECTRICAL DATA - AIR & WATER COOLED MODELS<br />

<strong>DF</strong>45X-EZR <strong>DF</strong>50X2-EZR <strong>DF</strong>55X2-EZR <strong>DF</strong>60X2-EZR<br />

<strong>DF</strong>45WX-EZR <strong>DF</strong>50WX2-EZR <strong>DF</strong>55WX2-EZR <strong>DF</strong>60WX2-EZR<br />

Standard Condenser Match - X CR80 CR80 CR80 CR80<br />

Unit Data - X (1)<br />

Nominal Run Amps A 78.8 92.2 96.0 104.2<br />

Maximum Start Amps A 212.8 233.2 209.1 247.8<br />

Recommended Mains Fuse Size A 100 100 100 125<br />

Max Mains Incoming Cable Size mm² 35 50 50 50<br />

Mains Supply V 400V / 3PH + N / 50Hz<br />

Control circuit VAC 24 24 24 24<br />

Unit Data - WX (2)<br />

Nominal Run Amps A 70.1 83.5 87.3 95.5<br />

Maximum Start Amps A 204.1 224.5 200.4 239.1<br />

Recommended Mains Fuse Size A 80 100 100 100<br />

Max Mains Incoming Cable Size mm² 35 35 35 35<br />

Mains Supply V 400V / 3PH + N / 50Hz<br />

Control circuit VAC 24 24 24 24<br />

Evaporator Fan - AC Motor - Per Fan<br />

Quantity x Motor Size (3) kW 1 x 5.5 2 x 2.2 2 x 2.2 2 x 3.0<br />

Full Load Amps A 10.9 4.7 4.7 6.3<br />

Locked Rotor Amps A 76.3 32.9 32.9 44.1<br />

Compressor - Per Compressor<br />

Quantity x Motor Size kW 1 x 13.72 2 x 8.57 2 x 9.46 2 x 10.86<br />

Nominal Run Amps A 26.00 15.00 16.90 19.40<br />

Locked Rotor Amps A 160 156 130 163<br />

Type of Start Direct On Line<br />

Standard Condenser Match - AC Motor<br />

- Per Fan<br />

Quantity x Motor Size kW 3 x 0.63 3 x 0.63 3 x 0.63 3 x 0.63<br />

Full Load Amps A 2.90 2.90 2.90 2.90<br />

OPTIONAL EXTRAS<br />

Electric Heating<br />

Stage of Reheat 3 3 3 3<br />

Number of Elements 8 12 12 12<br />

Rating (Total) kW 20.0 30.0 30.0 30.0<br />

Current Per Phase A 32.7 43.6 43.6 43.6<br />

Humidifier<br />

Capacity kg/hr 3.00 - 15.00 3.00 - 15.00 3.00 - 15.00 3.00 - 15.00<br />

Rating kW 11.25 11.25 11.25 11.25<br />

Full Load Amps A 15.80 15.80 15.80 15.80<br />

Evaporator Fan Options:<br />

Larger Fan Motor - AC Motor - Per Fan<br />

Quantity x Motor Size (3) kW N/A 2 x 3.0 / 2 x 4.0 2 x 3.0 / 2 x 4.0 2 x 4.0<br />

Full Load Amps A N/A 6.3 / 6.3 / 8.2<br />

Locked Rotor Amps A N/A 44.1 / 5 44.1 / 5 57.4<br />

Standard Size Motor - EC Motor - Per Fan<br />

Quantity x Motor Size (3) kW 2 x 2.63 2 x 3.1 2 x 3.1 2 x 3.1<br />

Full Load Amps A 4.90 4.9 4.9 4.9<br />

Standard Condenser Match - EC Motor -<br />

Per Fan<br />

Quantity x Motor Size kW 3 x 0.77 3 x 0.77 3 x 0.77 3 x 0.77<br />

Full Load Amps A 3.30 3.30 3.30 3.30<br />

(1) Values given for full function units (incl. electric heating, humidification and matched condenser) at 7°C evaporating and 54.4°C condensing with<br />

standard fan AC motors, for optional data, please contact Airedale.<br />

(2) Values given for full function units (incl. electric heating and humidification) at 7°C evaporating and 54.4°C condensing with standard fan AC motors,<br />

for optional data, please contact Airedale.<br />

(3) AC fan motors: motor size relates to the shaft power. EC fan motors: motor size relates to the absorbed electrical power.


<strong>TECHNICAL</strong> UPDATE<br />

Date: 25/07/2008 Sheet 15 of 24<br />

MECHANICAL DATA - CHILLED WATER MODELS<br />

<strong>DF</strong>6CW-EZR <strong>DF</strong>8CW-EZR <strong>DF</strong>10CW-EZR <strong>DF</strong>13CW-EZR<br />

Capacity (1)<br />

Nom Cooling (Gross) kW 8.0 9.2 11.1 14.8<br />

Fan Gain<br />

Dimensions<br />

kW 1 x 0.33 1 x 0.60 1 x 0.65 1 x 0.65<br />

H x D x W<br />

Weight<br />

mm 1940 x 670 x 670 1940 x 670 x 670 1940 x 670 x 670 1940 x 670 x 990<br />

Machine (2) kg 155 165 168 195<br />

Construction<br />

Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Light Grey, (RAL 7035) / Frame:<br />

Material/Colour<br />

Anodised Aluminium Frame with Black Nylon Corners<br />

Cooling Coil Copper Tube/Turbulated Hydrophilic Coated Aluminium Fins<br />

Cooling/Dehum Stages 1 (Modulated) / 1<br />

Evaporator Fan Motor - AC Motor Centrifugal Forward Curved Direct Drive - Designed to 25Pa ESP<br />

Quantity x Motor Size (3) kW 1 x 0.30 1 x 0.55 1 x 0.60 1 x 0.60<br />

Maximum ESP Pa 196 140 118 294<br />

Nominal Airflow<br />

Connections<br />

m³/s 0.55 0.75 0.95 1.00<br />

Inlet/Outlet mm 22 22 22 28<br />

Condensate Drain Hose mm 19 19 19 19<br />

Filtration Disposable to BS EN 779 - G4 - 50mm<br />

Quantity<br />

OPTIONAL EXTRAS<br />

1 1 1 2<br />

Electric Heating (Total)<br />

Humidifier<br />

kW 7.5 7.5 7.5 7.5<br />

Capacity kg/hr 0.6 - 3.0 0.6 - 3.0 0.6 - 3.0 0.6 - 3.0<br />

Feed/Drain<br />

Condensate Pump<br />

3/4” BSPF Braided flexible hose/19mm hose connection<br />

Head m 8 8 8 8<br />

Flow l/m 5 5 5 5<br />

Drain<br />

Evaporator Fan Options:<br />

10mm S/Steel Stub Connection<br />

Larger Fan Motor - AC Motor Centrifugal Forward Curved Direct Drive - Designed to 25Pa ESP<br />

Quantity x Motor Size (3) kW 1 x 0.55 1 x 0.60 N/A N/A<br />

Maximum ESP Pa 254 253 N/A N/A<br />

Fan Gain kW 1 x 0.60 1 x 0.65 N/A N/A<br />

Standard Fan Motor - EC Motor Centrifugal Backward Curved Direct Drive - Designed to 25Pa ESP<br />

Quantity x Motor Size (3) kW 1 x 0.94 1 x 0.94 1 x 0.94 1 x 1.01<br />

Speed @ 25Pa / Maximum ESP rpm 1335 / 2215 1705 / 2215 2145 / 2215 1105 / 1560<br />

Maximum ESP Pa 475 295 50 310<br />

Fan Gain rpm 1 x 0.32 1 x 0.32 1 x 0.32 1 x 0.35<br />

Low Pressure Hot Water Copper Tube/Aluminium Fin<br />

Capacity Gross (4) kW 6.50 7.50 8.40 11.50<br />

Water Flow (Nominal) l/s 0.14 0.17 0.19 0.26<br />

LPHW Connection Sizes<br />

Threaded Connections<br />

mm 22 22 22 22<br />

Brass Male Taper in 3/4 3/4 3/4 1<br />

(1) Entering air 24°C/45% RH water 7°C/12°C.<br />

(2) With Standard AC fan motors, refer to Weights, on page 6 for units with Optional EC fan motors.<br />

(3) AC fan motors: motor size relates to the shaft power. EC fan motors: motor size relates to the absorbed electrical power.<br />

(4) Based upon low pressure hot water 82°C inlet/71°C outlet. Air on 20°C. Refer to Low Pressure Hot Water (Optional Extra), page 41 in<br />

main manual.


<strong>TECHNICAL</strong> UPDATE<br />

Date: 25/07/2008 Sheet 16 of 24<br />

MECHANICAL DATA - CHILLED WATER MODELS<br />

<strong>DF</strong>15CW-EZR <strong>DF</strong>17CW-EZR <strong>DF</strong>20CW-EZR <strong>DF</strong>22CW-EZR <strong>DF</strong>26CW-EZR<br />

Capacity (1)<br />

Nom Cooling (Gross) kW 17.5 19.6 22.1 24.6 27.8<br />

Fan Gain<br />

Dimensions<br />

kW 1 x 1.20 1 x 1.20 2 x 0.65 2 x 0.65 2 x 0.65<br />

H x D x W<br />

Weight<br />

mm 1940 x 670 x 990 1940 x 670 x 990 1940 x 670 x 1310 1940 x 670 x 1310 1940 x 670 x 1310<br />

Machine (2) kg 200 200 252 252 252<br />

Construction<br />

Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Light Grey, (RAL 7035) / Frame:<br />

Material/Colour<br />

Anodised Aluminium Frame with Black Nylon Corners<br />

Cooling Coil Copper Tube/Turbulated Hydrophilic Coated Aluminium Fins<br />

Cooling/Dehum Stages 1 (Modulated) / 1<br />

Evaporator Fan Motor - AC Motor Centrifugal Forward Curved Direct Drive - Designed to 25Pa ESP<br />

Quantity x Motor Size (3) kW 1 x 1.10 1 x 1.10 2 x 0.60 2 x 0.60 2 x 0.60<br />

Maximum ESP Pa 120 34 260 194 43<br />

Nominal Airflow<br />

Connections<br />

m³/s 1.20 1.40 1.50 1.70 2.00<br />

Inlet/Outlet mm 28 28 28 28 28<br />

Condensate Drain Hose mm 19 19 19 19 19<br />

Filtration Disposable to BS EN 779 - G4 - 50mm<br />

Quantity<br />

OPTIONAL EXTRAS<br />

2 2 3 3 3<br />

Electric Heating (Total)<br />

Humidifier<br />

kW 7.5 7.5 15.0 15.0 15.0<br />

Capacity kg/hr 0.6 - 3.0 0.6 - 3.0 0.6 - 3.0 0.6 - 3.0 0.6 - 3.0<br />

Feed/Drain<br />

Condensate Pump<br />

3/4” BSPF Braided flexible hose/19mm hose connection<br />

Head m 8 8 8 8 8<br />

Flow l/m 5 5 5 5 5<br />

Drain<br />

Evaporator Fan Options:<br />

10mm S/Steel Stub Connection<br />

Larger Fan Motor - AC Motor Centrifugal Forward Curved Direct Drive - Designed to 25Pa ESP<br />

Quantity x Motor Size (3) kW N/A N/A N/A N/A N/A<br />

Maximum ESP Pa N/A N/A N/A N/A N/A<br />

Fan Gain kW N/A N/A N/A N/A N/A<br />

Standard Fan Motor - EC Motor Centrifugal Backward Curved Direct Drive - Designed to 25Pa ESP<br />

Quantity x Motor Size (3) kW 1 x 1.01 1 x 1.01 1 x 2.63 1 x 2.63 1 x 2.63<br />

Speed @ 25Pa / Maximum ESP rpm 1310 / 1560 1515 / 1560 1745 / 2165 2055 / 2165 2055 / 2165<br />

Maximum ESP Pa 195 45 450 145 145<br />

Fan Gain rpm 1 x 0.35 1 x 0.35 1 x 0.91 1 x 0.91 1 x 0.91<br />

Low Pressure Hot Water Copper Tube/Aluminium Fin<br />

Capacity Gross (4) kW 12.50 13.30 16.10 16.10 16.60<br />

Water Flow (Nominal) l/s 0.28 0.30 0.36 0.36 0.37<br />

LPHW Connection Sizes<br />

Threaded Connections<br />

mm 22 22 22 22 22<br />

Brass Male Taper in 1 1 1 1 1<br />

(1) Entering air 24°C/45% RH water 7°C/12°C.<br />

(2) With Standard AC fan motors, refer to Weights, on page 6 for units with Optional EC fan motors.<br />

(3) AC fan motors: motor size relates to the shaft power. EC fan motors: motor size relates to the absorbed electrical power.<br />

(4) Based upon low pressure hot water 82°C inlet/71°C outlet. Air on 20°C. Refer to Low Pressure Hot Water (Optional Extra), page 41 in<br />

main manual.


<strong>TECHNICAL</strong> UPDATE<br />

Date: 25/07/2008 Sheet 17 of 24<br />

MECHANICAL DATA - CHILLED WATER MODELS<br />

<strong>DF</strong>28CW-EZR <strong>DF</strong>31CW-EZR <strong>DF</strong>35CW-EZR <strong>DF</strong>40CW-EZR<br />

Capacity<br />

Nom Cooling (Gross) (1) kW 34.5 38.4 44.8 50.8<br />

Fan Gain<br />

Dimensions<br />

kW 1 x 1.43 1 x 2.60 1 x 2.60 1 x 3.58<br />

H x D x W<br />

Weight<br />

mm 1940 x 750 x 1460 1940 x 750 x 1460 1940 x 750 x 1835 1940 x 750 x 1835<br />

Machine (2) kg 351 354 410 431<br />

Construction<br />

Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Light Grey, (RAL 7035) / Frame:<br />

Material/Colour<br />

Anodised Aluminium Frame with Black Nylon Corners<br />

Cooling Coil Copper Tube/Turbulated Hydrophilic Coated Aluminium Fins<br />

Cooling/Dehum Stages 1 (Modulated) / 1<br />

Evaporator Fan Motor - AC Motor Centrifugal Forward Curved Belt & Pulley - Designed to 25Pa ESP<br />

Quantity x Motor Size (3) kW 1 x 2.2 1 x 4.0 1 x 4.0 1 x 5.5<br />

Speed @ 25Pa / Maximum ESP rpm 871 / 909 1008 / 1171 980 / 1078 1094 / 1186<br />

Maximum ESP Pa 75 265 165 175<br />

Nominal Airflow<br />

Connections<br />

m³/s 2.4 2.8 3.3 3.7<br />

Inlet/Outlet mm 42 42 42 42<br />

Condensate Drain Hose mm 19 19 19 19<br />

Filtration Disposable to BS EN 779 - G4 - 75mm<br />

Quantity<br />

OPTIONAL EXTRAS<br />

3 3 3 3<br />

Electric Heating (Total)<br />

Humidifier<br />

kW 20 20 20 20<br />

Capacity kg/hr 1.6 - 8.0 1.6 - 8.0 3.0 - 15.0 3.0 - 15.0<br />

Feed/Drain<br />

Condensate Pump<br />

3/4” BSPF Braided flexible hose / 19mm hose connection<br />

Head m 10.8 10.8 10.8 10.8<br />

Flow l/m 5 5 5 5<br />

Drain<br />

Evaporator Fan Options:<br />

10mm S/Steel Stub Connection<br />

Larger Fan Motor - AC Motor Centrifugal Forward Curved Direct Drive - Designed to 25Pa ESP<br />

Quantity x Motor Size (3) kW 1 x 3.00 / 1 x 4.00 N/A 1 x 5.50 N/A<br />

Speed @ Maximum ESP rpm 1144 / 1439 N/A 1196 N/A<br />

Maximum ESP Pa 362 / 722 N/A 322 N/A<br />

Fan Gain kW 1 x 1.95 / 1 x 2.60 N/A 1 x 3.58 N/A<br />

Standard Fan Motor - EC Motor Centrifugal Backward Curved Direct Drive - Designed to 25Pa ESP<br />

Quantity x Motor Size (3) kW 2 x 2.63 2 x 2.63 2 x 2.63 2 x 2.63<br />

Speed @ 25Pa / Maximum ESP rpm 1570 / 2165 1775 / 2165 1895 / 2165 2135 / 2165<br />

Maximum ESP Pa 595 390 285 70<br />

Fan Gain rpm 2 x 1.83 2 x 1.83 2 x 1.83 2 x 1.83<br />

Low Pressure Hot Water Copper Tube/Aluminium Fin<br />

Capacity Gross (4) kW 21.30 22.70 30.00 31.50<br />

Water Flow (Nominal) l/s 0.48 0.51 0.67 0.70<br />

LPHW Connection Sizes<br />

Threaded Connections<br />

mm 22 22 22 22<br />

Brass Male Taper in 1 1/2 1 1/2 1 1/2 1 1/2<br />

(1) Entering air 24°C/45% RH water 7°C/12°C.<br />

(2) With Standard AC fan motors, refer to Weights, on page 6 for units with Optional EC fan motors.<br />

(3) AC fan motors: motor size relates to the shaft power. EC fan motors: motor size relates to the absorbed electrical power.<br />

(4) Based upon low pressure hot water 82°C inlet/71°C outlet. Air on 20°C. Refer to Low Pressure Hot Water (Optional Extra), page 41 in<br />

main manual.


<strong>TECHNICAL</strong> UPDATE<br />

Date: 25/07/2008 Sheet 18 of 24<br />

MECHANICAL DATA - CHILLED WATER MODELS<br />

<strong>DF</strong>45CW-EZR <strong>DF</strong>50CW-EZR <strong>DF</strong>55CW-EZR <strong>DF</strong>60CW-EZR<br />

Capacity<br />

Nom Cooling (Gross) (1) kW 53.6 51.9 59.0 59.2<br />

Fan Gain<br />

Dimensions<br />

kW 1 x 3.58 2 x 1.43 2 x 1.43 2 x 1.95<br />

H x D x W<br />

Weight<br />

mm 1940 x 750 x 1835 1940 x 750 x 2170 1940 x 750 x 2170 1940 x 750 x 2170<br />

Machine (2) kg 442 486 499 495<br />

Construction<br />

Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Light Grey, (RAL 7035) / Frame:<br />

Material/Colour<br />

Anodised Aluminium Frame with Black Nylon Corners<br />

Cooling Coil Copper Tube/Turbulated Hydrophilic Coated Aluminium Fins<br />

Cooling/Dehum Stages 1 (Modulated) / 1<br />

Evaporator Fan Motor - AC Motor Centrifugal Forward Curved Belt & Pulley - Designed to 25Pa ESP<br />

Quantity x Motor Size (3) kW 1 x 5.5 2 x 2.2 2 x 2.2 2 x 3.0<br />

Speed @ 25Pa / Maximum ESP rpm 1094 / 1186 1167 / 1170 1167 / 1170 1307 / 1311<br />

Maximum ESP Pa 175 35 35 75<br />

Nominal Airflow<br />

Connections<br />

m³/s 3.7 4.2 4.2 4.6<br />

Inlet/Outlet mm 42 42 42 42<br />

Condensate Drain Hose mm 19 19 19 19<br />

Filtration Disposable to BS EN 779 - G4 - 75mm<br />

Quantity<br />

OPTIONAL EXTRAS<br />

3 4 4 4<br />

Electric Heating (Total)<br />

Humidifier<br />

kW 20 30 30 30<br />

Capacity kg/hr 3.0 - 15.0 3.0 - 15.0 3.0 - 15.0 3.0 - 15.0<br />

Feed/Drain<br />

Condensate Pump<br />

3/4” BSPF Braided flexible hose / 19mm hose connection<br />

Head m 10.8 10.8 10.8 10.8<br />

Flow l/m 5 5 5 5<br />

Drain<br />

Evaporator Fan Options:<br />

10mm S/Steel Stub Connection<br />

Larger Fan Motor - AC Motor Centrifugal Forward Curved Direct Drive - Designed to 25Pa ESP<br />

Quantity x Motor Size (3) kW N/A 2 x 3.00 / 2 x 4.0 2 x 3.00 / 2 x 4.0 2 x 4.0<br />

Speed @ Maximum ESP rpm N/A 1448 / 1498 1448 / 1498 1497<br />

Maximum ESP Pa N/A 310 / 360 310 / 360 275<br />

Fan Gain kW N/A 2 x 1.95 / 2 x 2.6 2 x 1.95 / 2 x 2.6 2 x 2.6<br />

Standard Fan Motor - EC Motor Centrifugal Backward Curved Direct Drive - Designed to 25Pa ESP<br />

Quantity x Motor Size (3) kW 2 x 2.63 2 x 3.10 2 x 3.10 2 x 3.10<br />

Speed @ 25Pa / Maximum ESP rpm 2135 / 2165 1265 / 1510 1265 / 1510 1390 / 1510<br />

Maximum ESP Pa 70 320 320 185<br />

Fan Gain rpm 2 x 1.83 2 x 2.16 2 x 2.16 2 x 2.16<br />

Low Pressure Hot Water Copper Tube/Aluminium Fin<br />

Capacity Gross (4) kW 31.50 38.30 38.30 39.80<br />

Water Flow (Nominal) l/s 0.70 0.85 0.85 0.89<br />

LPHW Connection Sizes<br />

Threaded Connections<br />

mm 22 22 22 22<br />

Brass Male Taper in 1 1/2 1 1/2 1 1/2 1 1/2<br />

(1) Entering air 24°C/45% RH water 7°C/12°C.<br />

(2) With Standard AC fan motors, refer to Weights, on page 6 for units with Optional EC fan motors.<br />

(3) AC fan motors: motor size relates to the shaft power. EC fan motors: motor size relates to the absorbed electrical power.<br />

(4) Based upon low pressure hot water 82°C inlet/71°C outlet. Air on 20°C. Refer to Low Pressure Hot Water (Optional Extra), page 41 in<br />

main manual.


<strong>TECHNICAL</strong> UPDATE<br />

Date: 25/07/2008 Sheet 19 of 24<br />

ELECTRICAL DATA - CHILLED WATER MODELS<br />

<strong>DF</strong>6CW-EZR <strong>DF</strong>8CW-EZR <strong>DF</strong>10CW-EZR <strong>DF</strong>13CW-EZR<br />

Unit Data (1)<br />

Nominal Run Amps A 18.4 21.7 22.6 22.6<br />

Maximum Start Amps A 18.4 21.7 22.6 22.6<br />

Recommended Mains Fuse Size A 25 32 32 32<br />

Max Mains Incoming Cable Size mm² 6 6 6 35<br />

Mains Supply V 400V / 3PH + N / 50Hz<br />

Control circuit<br />

Evaporator Fan - AC Motor - Per Fan<br />

VAC 24 24 24 24<br />

Quantity x Motor Size (2) kW 1 x 0.30 1 x 0.55 1 x 0.60 1 x 0.60<br />

Full Load Amps A 3.50 6.80 7.70 7.70<br />

Locked Rotor Amps<br />

OPTIONAL EXTRAS<br />

Electric Heating<br />

A 8.75 17.00 20.50 20.50<br />

Stage of Reheat 1 1 1 1<br />

Number of Elements 3 3 3 3<br />

Rating (Total) kW 7.5 7.5 7.5 7.5<br />

Current Per Phase<br />

Humidifier<br />

A 10.9 10.9 10.9 10.9<br />

Capacity kg/hr 0.60 - 3.00 0.60 - 3.00 0.60 - 3.00 0.60 - 3.00<br />

Rating kW 2.25 2.25 2.25 2.25<br />

Full Load Amps<br />

Evaporator Fan Options:<br />

A 3.50 3.50 3.50 3.50<br />

Larger Fan Motor - AC Motor - Per Fan<br />

Quantity x Motor Size (2) kW 1 x 0.55 1 x 0.60 N/A N/A<br />

Full Load Amps A 6.80 7.70 N/A N/A<br />

Locked Rotor Amps A 17.00 20.50 N/A N/A<br />

Standard Size Motor - EC Motor - Per Fan<br />

Quantity x Motor Size (2) kW 1 x 0.94 1 x 0.94 1 x 0.94 1 x 1.01<br />

Full Load Amps A 1.50 1.50 1.50 1.60<br />

<strong>DF</strong>15CW-EZR <strong>DF</strong>17CW-EZR <strong>DF</strong>20CW-EZR <strong>DF</strong>22CW-EZR <strong>DF</strong>26CW-EZR<br />

Unit Data (1)<br />

Nominal Run Amps A 24.9 24.9 41.2 41.2 41.2<br />

Maximum Start Amps A 25.5 25.5 41.5 41.5 41.5<br />

Recommended Mains Fuse Size A 32 32 50 50 50<br />

Max Mains Incoming Cable Size mm² 35 35 35 35 35<br />

Mains Supply V 400V / 3PH + N / 50Hz<br />

Control circuit<br />

Evaporator Fan - AC Motor - Per Fan<br />

VAC 24 24 24 24 24<br />

Quantity x Motor Size (2) kW 1 x 1.1 1 x 1.1 2 x 0.6 2 x 0.6 2 x 0.6<br />

Full Load Amps A 10.0 10.0 7.7 7.7 7.7<br />

Locked Rotor Amps<br />

OPTIONAL EXTRAS<br />

Electric Heating<br />

A 25.0 25.0 20.5 20.5 20.5<br />

Stage of Reheat 1 1 2 2 2<br />

Number of Elements 3 3 6 6 6<br />

Rating (Total) kW 7.5 7.5 15.0 15.0 15.0<br />

Current Per Phase<br />

Humidifier<br />

A 10.9 10.9 21.8 21.8 21.8<br />

Capacity kg/hr 0.60 - 3.00 0.60 - 3.00 0.60 - 3.00 0.60 - 3.00 0.60 - 3.00<br />

Rating kW 2.25 2.25 2.25 2.25 2.25<br />

Full Load Amps<br />

Evaporator Fan Options:<br />

A 3.50 3.50 3.50 3.50 3.50<br />

Larger Fan Motor - AC Motor - Per Fan<br />

Quantity x Motor Size (2) kW N/A N/A N/A N/A N/A<br />

Full Load Amps A N/A N/A N/A N/A N/A<br />

Locked Rotor Amps A N/A N/A N/A N/A N/A<br />

Standard Size Motor - EC Motor - Per Fan<br />

Quantity x Motor Size (2) kW 1 x 1.01 1 x 1.01 1 x 2.63 1 x 2.63 1 x 2.63<br />

Full Load Amps A 1.60 1.60 4.90 4.90 4.90<br />

(1) Values given for full function units (incl. electric heating, humidification and matched condenser) at 7°C evaporating and 54.4°C condensing with<br />

standard fan AC motors, for optional data, please contact Airedale.<br />

(2) AC fan motors: motor size relates to the shaft power. EC fan motors: motor size relates to the absorbed electrical power.


<strong>TECHNICAL</strong> UPDATE<br />

Date: 25/07/2008 Sheet 20 of 24<br />

ELECTRICAL DATA - CHILLED WATER MODELS<br />

<strong>DF</strong>28CW-EZR <strong>DF</strong>31CW-EZR <strong>DF</strong>35CW-EZR <strong>DF</strong>40CW-EZR<br />

Unit Data (1)<br />

Nominal Run Amps A 46.6 50.1 57.2 59.9<br />

Maximum Start Amps A 46.6 57.9 57.9 76.8<br />

Recommended Mains Fuse Size A 50 63 63 80<br />

Max Mains Incoming Cable Size mm² 35 35 35 35<br />

Mains Supply V 400V / 3PH + N / 50Hz<br />

Control circuit VAC 24 24 24 24<br />

Evaporator Fan - AC Motor - Per Fan<br />

Quantity x Motor Size (2) kW 1 x 2.2 1 x 4.0 1 x 4.0 1 x 5.5<br />

Full Load Amps A 4.7 8.2 8.2 10.9<br />

Locked Rotor Amps<br />

OPTIONAL EXTRAS<br />

Electric Heating<br />

A 32.9 57.4 57.4 76.3<br />

Stage of Reheat 3 3 3 3<br />

Number of Elements 8 8 8 8<br />

Rating (Total) kW 20.0 20.0 20.0 20.0<br />

Current Per Phase<br />

Humidifier<br />

A 32.4 32.4 32.4 32.4<br />

Capacity kg/hr 1.60 - 8.00 1.60 - 8.00 3.00 - 15.00 3.00 - 15.00<br />

Rating kW 6.00 6.00 11.25 11.25<br />

Full Load Amps<br />

Evaporator Fan Options:<br />

A 8.70 8.70 15.80 15.80<br />

Larger Fan Motor - AC Motor - Per Fan<br />

Quantity x Motor Size (2) kW 1 x 3.0 / 1 x 4.0 N/A 1 x 5.5 N/A<br />

Full Load Amps A 6.3 / 8.2 N/A 10.9 N/A<br />

Locked Rotor Amps A 44.1 / 57.4 N/A 76.3 N/A<br />

Standard Size Motor - EC Motor - Per Fan<br />

Quantity x Motor Size (2) kW 2 x 2.63 2 x 2.63 2 x 2.63 2 x 2.63<br />

Full Load Amps A 4.90 4.90 4.90 4.90<br />

<strong>DF</strong>45CW-EZR <strong>DF</strong>50CW-EZR <strong>DF</strong>55CW-EZR <strong>DF</strong>60CW-EZR<br />

Unit Data (1)<br />

Nominal Run Amps A 59.9 69.3 69.3 72.5<br />

Maximum Start Amps A 76.8 69.3 69.3 88.7<br />

Recommended Mains Fuse Size A 80 80 80 80<br />

Max Mains Incoming Cable Size mm² 35 50 50 50<br />

Mains Supply V 400V / 3PH + N / 50Hz<br />

Control circuit VAC 24 24 24 24<br />

Evaporator Fan - AC Motor - Per Fan<br />

Quantity x Motor Size (2) kW 1 x 5.5 2 x 2.2 2 x 2.2 2 x 3.0<br />

Full Load Amps A 10.9 4.7 4.7 6.3<br />

Locked Rotor Amps<br />

OPTIONAL EXTRAS<br />

Electric Heating<br />

A 76.3 32.9 32.9 44.1<br />

Stage of Reheat 3 3 3 3<br />

Number of Elements 8 12 12 12<br />

Rating (Total) kW 20.0 30.0 30.0 30.0<br />

Current Per Phase<br />

Humidifier<br />

A 32.4 43.6 43.6 43.6<br />

Capacity kg/hr 3.00 - 15.00 3.00 - 15.00 3.00 - 15.00 3.00 - 15.00<br />

Rating kW 11.25 11.25 11.25 11.25<br />

Full Load Amps<br />

Evaporator Fan Options:<br />

A 15.80 15.80 15.80 15.80<br />

Larger Fan Motor - AC Motor - Per Fan<br />

Quantity x Motor Size (2) kW N/A 2 x 3.0 / 2 x 4.0 2 x 3.0 / 2 x 4.0 2 x 4.0<br />

Full Load Amps A N/A 6.3 / 6.3 / 8.2<br />

Locked Rotor Amps A N/A 44.1 / 5 44.1 / 5 57.4<br />

Standard Size Motor - EC Motor - Per Fan<br />

Quantity x Motor Size (2) kW 2 x 2.63 2 x 3.1 2 x 3.1 2 x 3.1<br />

Full Load Amps A 4.90 4.9 4.9 4.9<br />

(1) Values given for full function units (incl. electric heating, humidification and matched condenser) at 7°C evaporating and 54.4°C condensing with<br />

standard fan AC motors, for optional data, please contact Airedale.<br />

(2) AC fan motors: motor size relates to the shaft power. EC fan motors: motor size relates to the absorbed electrical power.


<strong>TECHNICAL</strong> UPDATE<br />

Date: 25/07/2008 Sheet 21 of 24<br />

Outdoor Unit<br />

DIMENSIONS / WEIGHTS / POSITIONING - HORIZONTAL<br />

IMPORTANT<br />

Unit diagrams can be supplied on request.<br />

The legs attached to the top of the unit are for lifting and stacking and may be removed and<br />

stored safely if not required.<br />

Only 2 units may be stacked together.<br />

Standard Condenser Fan (CR12 - CR30 Shown)<br />

B<br />

(3)<br />

500<br />

(2)<br />

(6)<br />

(7)<br />

500<br />

(2)<br />

D<br />

A<br />

(1)<br />

(1)<br />

3000<br />

(2)<br />

500<br />

(2)<br />

(4)<br />

(5a)<br />

(1)<br />

(5b)<br />

C<br />

(1)<br />

150 E 150<br />

Optional Short Case Axial Fan (SCAF) (CR80 - CR105 Shown)<br />

B<br />

500<br />

(2)<br />

(6)<br />

(7)<br />

(8)<br />

(1)<br />

(1)<br />

D<br />

500<br />

(2)<br />

(3)<br />

3000<br />

(2)<br />

A<br />

D<br />

(1)<br />

(1)<br />

500<br />

(2)<br />

(5b)<br />

(4)<br />

(5a)<br />

(1)<br />

C<br />

(1)<br />

150 E 150<br />

Diagram illustrated in mm<br />

(1) Airflow<br />

(2) Minimum clearances<br />

(3) 12.7mm fixing hole<br />

(4) Mains electric isolator<br />

(5) Service connections to left hand side of the unit:<br />

a = Discharge gas inlet (ALWAYS above (b))<br />

b = Liquid outlet<br />

(6) Top brackets may be used to secure unit of similar size<br />

on top, using, 2 x 12.7mm fixing holes<br />

(7) 40mm lifting holes<br />

Diagram illustrated in mm<br />

(1) Airflow<br />

(2) Minimum clearances<br />

(3) 12.7mm fixing hole<br />

(4) Mains electric isolator<br />

(5) Service connections to left hand side of the unit:<br />

a = Discharge gas inlet (ALWAYS above (b))<br />

b = Liquid outlet<br />

(6) Top brackets may be used to secure unit of similar size<br />

on top, using, 2 x 12.7mm fixing holes<br />

(7) 40mm lifting holes<br />

(8) Optional Short Case Axial Fan with integral duct fixing<br />

holes<br />

DIMENSIONS (mm) WEIGHTS (kg)<br />

Standard Fan<br />

Standard Optional Optional<br />

A B C D E Fan EC Fan SCAF<br />

CR12 907 972 1000 845 700 62 67 67<br />

CR16 907 972 1000 845 700 70 76 75<br />

CR22 1102 1167 1000 1040 700 77 83 88<br />

CR30 1102 1167 1000 1040 700 90 96 101<br />

CR50 2184 1167 1000 2121 700 132 145 154<br />

CR65 2184 1167 1000 2121 700 162 175 184<br />

CR80 3565 1167 1000 1752 700 208 228 242<br />

CR105 3565 1167 1000 1752 700 260 280 294<br />

CAUTION<br />

A vertical air discharge unit is recommended for installation in windy locations or wherever a<br />

horizontal airflow would be obstructed.


<strong>TECHNICAL</strong> UPDATE<br />

Date: 25/07/2008 Sheet 22 of 24<br />

DIMENSIONS / WEIGHTS / POSITIONING - VERTICAL<br />

IMPORTANT<br />

Unit diagrams can be supplied on request.<br />

Standard Condenser Fan (CR12 - CR30 Shown)<br />

(6)<br />

B<br />

(3)<br />

D<br />

A<br />

(1)<br />

(1)<br />

(4)<br />

(5b)<br />

3000<br />

(2)<br />

E<br />

C<br />

The following illustrations show the unit following fixing leg re-orientation,<br />

instructions are provided for this at delivery.<br />

(5a)<br />

Optional Short Case Axial Fan (SCAF) (CR80 - CR105 Shown)<br />

B<br />

(3)<br />

500<br />

(2)<br />

(6)<br />

500<br />

(2)<br />

500<br />

(2)<br />

(1)<br />

(1)<br />

D<br />

(7)<br />

A<br />

D<br />

(1)<br />

(1)<br />

500<br />

(2)<br />

500<br />

(2)<br />

500<br />

(2)<br />

500<br />

(2)<br />

(4)<br />

(5b)<br />

3000<br />

(2)<br />

E<br />

C<br />

500<br />

(2)<br />

(5a)<br />

Diagram illustrated in mm<br />

(1) Airflow<br />

(2) Minimum clearances<br />

(3) 12.7mm fixing hole<br />

(4) Mains electric isolator<br />

(5) Service connections to left hand side of the unit:<br />

a = Liquid outlet<br />

b = Discharge gas inlet<br />

(6) 40mm lifting holes<br />

Diagram illustrated in mm<br />

(1) Airflow<br />

(2) Minimum clearances<br />

(3) 12.7mm fixing hole<br />

(4) Mains electric isolator<br />

(5) Service connections to left hand side of the unit:<br />

a = Liquid outlet<br />

b = Discharge gas inlet<br />

(6) 40mm lifting holes<br />

(7) Optional short case axial fan with integral duct fixing holes<br />

DIMENSIONS (mm) WEIGHTS (kg)<br />

A<br />

Standard Fan<br />

B C D E<br />

Fan Options<br />

SCAF<br />

B<br />

EC<br />

B<br />

Standard<br />

AC Fan<br />

Optional<br />

EC Fan<br />

Optional<br />

SCAF<br />

CR12 907 1076 972 847 912 1080 1065 62 67 67<br />

CR16 907 1076 972 847 912 1080 1065 70 76 75<br />

CR22 1102 1090 1167 1042 1107 1130 1127 77 83 88<br />

CR30 1102 1090 1167 1042 1107 1130 1127 90 96 101<br />

CR50 2184 1090 1167 2124 1107 1130 1127 132 145 154<br />

CR65 2184 1090 1167 2124 1107 1130 1127 162 175 184<br />

CR80 3565 1090 1167 1753 1107 1130 1127 208 228 242<br />

CR105 3565 1090 1167 1753 1107 1130 1127 260 280 294


<strong>TECHNICAL</strong> UPDATE<br />

Date: 25/07/2008 Sheet 23 of 24<br />

UNIT LIFTING<br />

General<br />

IMPORTANT<br />

• Employ lifting specialists<br />

• Local codes and regulations relating to the lifting of this type of equipment should<br />

be observed<br />

• Each chain/sling must be capable of lifting the whole unit<br />

• Lift the unit slowly and evenly<br />

Only use lifting points provided.<br />

Do not use 1 chain between 2 lifting points to avoid load shift.<br />

Ensure that chains/slings DO NOT crush the casework, coil or fan assemblies.<br />

If the unit is dropped it should immediately be checked for damage and reported<br />

to Airedale.<br />

Airedale will accept no responsibility for mishandling during the positioning of<br />

the equipment.<br />

CAUTION Check the unit is as ordered, discrepancies or transit damage should be reported<br />

to Airedale immediately.<br />

Horizontal Air Discharge The unit is delivered in horizontal air discharge configuration secured to a pallet. Where<br />

possible the unit should be moved with the pallet in place.<br />

Use 4 lifting eyes attached to 4 individual slings/chains<br />

(supplied by others) and attach 2 to each top leg using<br />

the holes provided as illustrated.<br />

Vertical Air Discharge The unit is delivered in horizontal air discharge configuration (with the mains isolator and<br />

fan speed controller already configured for vertical air discharge) secured to a pallet.<br />

Where possible the unit should be moved with the pallet in place.<br />

CAUTION<br />

Before lifting into final position, the unit legs should be re-orientated, refer to instructions<br />

provided at delivery.<br />

Care should be taken to ensure the unit does not sustain damage before it is lifted<br />

into final position.<br />

> 60°<br />

Use 4 lifting eyes attached to 4 individual slings/chains<br />

(supplied by others) and attach 1 to the top of each of the<br />

4 corner legs using the holes provided as illustrated.


<strong>TECHNICAL</strong> UPDATE<br />

Date: 25/07/2008 Sheet 24 of 24<br />

Notes: