1. The <strong>Knox</strong>-<strong>Box</strong> ® tamper switch is designed to be connected<br />
to an existing building alarm system and should be installed<br />
only by a qualified alarm technician.<br />
2. Remove tamper switch from lock box before mounting lock<br />
box.<br />
3. Position <strong>Knox</strong>-<strong>Box</strong> on wall so wires from alarm panel<br />
protrude into box through hole (A) in back plate. See figures<br />
1, 2, 3, & 4.<br />
4. Bolt <strong>Knox</strong>-<strong>Box</strong> to wall, following directions provided in<br />
mounting instructions.<br />
IMPORTANT: Keep tamper switch hole (B) clear of caulk,<br />
debris or other foreign material, otherwise tamper switch<br />
may not operate.<br />
5. Recessed Mount <strong>Knox</strong>-<strong>Box</strong> uses door tamper switch only,<br />
therefore, the rear tamper switch is omitted. To reinstall<br />
tamper switch assembly: Align tamper switch bracket screw<br />
holes with back plate holes as shown in Figure 1.<br />
6. Connect tamper switch wires to building alarm. Alarm<br />
wiring must be pulled back through the Alarm Wire<br />
Opening (A) and secured tightly so that if box is removed,<br />
wires will be broken in the process, thereby causing alarm<br />
activation.<br />
7. Surface Mount <strong>Knox</strong>-<strong>Box</strong>: Align rear tamper switch plunger<br />
in back plate, hole (B), as shown in figure 1. Check length<br />
of plunger and, if necessary, adjust plunger screw to give<br />
proper travel. Check plunger contact by GENTLY pressing<br />
the bracket flush against the back plate. CAUTION: If the rear<br />
tamper switch adjustment screw protrudes too far, the rear<br />
tamper switch may break when bracket is tightened. Use of<br />
an ohm meter is recommended to assure that switch trips<br />
(0 ohms – for red/green wires, open for yellow wires) when<br />
bracket is GENTLY pushed flush against the back plate.<br />
8. Secure bracket to back plate with screws provided. Do not<br />
allow wires to go behind mounting bracket, or between<br />
mounting bracket and box sidewall.<br />
9. Connect tamper switch wires to building alarm. Alarm<br />
wiring must be feed back through Alarm Wire Opening (A)<br />
to prevent interference with the lock mechanism.<br />
Figure 1<br />
Rear <strong>Tamper</strong><br />
<strong>Switch</strong> Plunger<br />
(Red Wires)<br />
Back Plate<br />
B<br />
A<br />
Inside View of Backplate<br />
Shown without Housing for Clarity<br />
<strong>Knox</strong>-<strong>Box</strong> ® <strong>3200</strong> <strong>Series</strong><br />
TAMPER SWITCH INSTALLATION INSTRUCTION<br />
Door <strong>Tamper</strong><br />
<strong>Switch</strong> Plunger<br />
(Green Wires)<br />
<strong>Tamper</strong> <strong>Switch</strong> Assembly<br />
<strong>Mounting</strong> Screws<br />
Lift-Off Door and Hinged Door<br />
Alarm Wire<br />
Exit Opening (A)<br />
Rear <strong>Tamper</strong><br />
<strong>Switch</strong> Hole<br />
B<br />
All mounting<br />
holes are 7/16"<br />
diameter. Use<br />
3/8" Grade 5 or<br />
Grade 8 fasteners<br />
NOTES:<br />
Inside View <strong>3200</strong><br />
With Hinged Door<br />
A<br />
Keep wires from going behind<br />
or under <strong>Tamper</strong> <strong>Switch</strong><br />
<strong>Mounting</strong> Bracket<br />
Rear <strong>Tamper</strong><br />
<strong>Switch</strong> Plunger<br />
(Red Wires)<br />
<strong>Tamper</strong> <strong>Switch</strong><br />
Assembly<br />
<strong>Mounting</strong> Screws<br />
Figure 2<br />
Alarm Wire<br />
Exit Opening<br />
<strong>Tamper</strong> <strong>Switch</strong> Bracket<br />
<strong>Mounting</strong> Holes<br />
Door <strong>Tamper</strong> <strong>Switch</strong><br />
1 2<br />
KNOX COMPANY • 1601 W. Deer Valley Road, Phoenix, AZ 85027 • (800) 552-5669 • (623) 687-2300 • Fax (623) 687-2299 • Web: www.knoxbox.com • E-mail: info@knoxbox.com<br />
© Copyright 2006. <strong>Knox</strong> Company<br />
OPE-KBSPEC-0060-B<br />
B<br />
All mounting holes<br />
are 7/16"diameter.<br />
Use 3/8"Grade 5<br />
or Grade 8 Fasteners<br />
Green Wires<br />
to Security Alarm Panel<br />
A) Electrical: maximum 24V, 50mA.<br />
<strong>Tamper</strong> <strong>Switch</strong><br />
Bracket<br />
<strong>Mounting</strong> Holes<br />
A<br />
Alarm Wire<br />
Exit Opening (A)<br />
Door <strong>Tamper</strong><br />
<strong>Switch</strong> Plunger<br />
(Green Wires)<br />
Inside View <strong>3200</strong> With Lift-Off Door<br />
Alarm Wire<br />
Exit Opening<br />
Figure 4<br />
Figure 3<br />
Wiring Diagram<br />
B<br />
A<br />
Rear <strong>Tamper</strong> <strong>Switch</strong><br />
1 2<br />
Red Wires<br />
to Security Alarm Panel<br />
Rear <strong>Tamper</strong><br />
<strong>Switch</strong> Hole<br />
B) Red and Green wires indicate Normally Open <strong>Switch</strong> (Closed when <strong>Knox</strong>-<strong>Box</strong> is secure)<br />
C) Yellow wires indicate Normally Closed <strong>Switch</strong> (Open when <strong>Knox</strong>-<strong>Box</strong> is secure)
TAMPER SWITCH<br />
INSTALLATION<br />
INSTRUCTIONS<br />
<strong>3200</strong> <strong>Series</strong><br />
KNOX-BOX ®<br />
<strong>3200</strong> TAMPER SW<br />
Issue Date: July 2006<br />
1601 W. Deer Valley Road<br />
Phoenix, AZ 85027<br />
800-552-5669 • Fax 623-687-2299<br />
E-mail: info@knoxbox.com<br />
OPE-KBSPEC-0060-B<br />
TAMPER SWITCH<br />
INSTALLATION<br />
INSTRUCTIONS<br />
<strong>3200</strong> <strong>Series</strong><br />
KNOX-BOX ®<br />
Issue Date: July 2006<br />
1601 W. Deer Valley Road<br />
Phoenix, AZ 85027<br />
800-552-5669 • Fax 623-687-2299<br />
E-mail: info@knoxbox.com<br />
<strong>3200</strong> TAMPER SW