Type WE 6 …H<br />

Size 6<br />

Component series 7X<br />

Maximum operating pressure 3 5 bar<br />

Maximum flow 60 l/min<br />

Table of contents Features<br />

Contents Page<br />

Features<br />

Ordering code 2<br />

St<strong>and</strong>ard types 2<br />

Plug-in connectors 2<br />

Spool symbols 3<br />

Function, section 4<br />

Technical data 5<br />

Characteristic curves 6<br />

Switching performance limits 6<br />

Unit dimensions 7, 8<br />

Information on available spare parts:<br />

www.boschrexroth.com/spc<br />

RE 23164/07.06<br />

Replaces: 02.06<br />

– Direct operated <strong>directional</strong> spool <strong>valve</strong> <strong>with</strong> solenoid actuation,<br />

st<strong>and</strong>ard version<br />

– Position of ports to DIN 24340 form A<br />

– For subplates, see data sheet RE 45052 (separate order)<br />

– Wet-<strong>pin</strong> <strong>DC</strong> <strong>solenoids</strong><br />

H7380<br />

– Electrical connection as individual connection<br />

– Concealed manual override<br />

– Solenoid coil can be rotated<br />

/8<br />

– Pressure-tight chamber needs not to be opened when coil is<br />

to be replaced


2/8 Bosch Rexroth AG Hydraulics WE 6 .…H RE 23164/07.06<br />

Ordering code<br />

3 service ports = 3<br />

4 service ports = 4<br />

Size 6 = 6<br />

Spool symbols e.g. D, E, etc.<br />

For possible versions, see page 3<br />

Component series 70 to 79 = 7X<br />

(70 to 79: unchanged installation <strong>and</strong> connection<br />

dimensions)<br />

Spring return = No code<br />

Without spring return <strong>with</strong> detent = OF )<br />

Wet-<strong>pin</strong> <strong>DC</strong> <strong>solenoids</strong> = H<br />

<strong>DC</strong> voltage 2 V = G12<br />

<strong>DC</strong> voltage 24 V = G24<br />

) Only <strong>with</strong> spool symbol D<br />

2) Plug-in connectors, separate order, see below<br />

3) Plug-in connectors, separate order, see RE 08006<br />

St<strong>and</strong>ard types<br />

Type Material number<br />

3WE 6 A7X/HG 2N9K4 R90 089276<br />

3WE 6 A7X/HG24N9K4 R90 089244<br />

4WE 6 C7X/HG 2N9K4 R90 089277<br />

4WE 6 C7X/HG24N9K4 R90 089245<br />

4WE 6 D7X/HG 2N9K4 R90 089273<br />

4WE 6 D7X/HG24N9K4 R90 087088<br />

Plug-in connectors to DIN EN 7530 -803<br />

For further plugin<br />

connectors,<br />

see RE 08006<br />

Valve<br />

side Colour<br />

Without circuitry<br />

WE 6 7X H N9 *<br />

With indicator lamp<br />

2 … 240 V<br />

Type Material number<br />

4WE 6 Y7X/HG 2N9K4 R90 089274<br />

4WE 6 Y7X/HG24N9K4 R90 089243<br />

4WE 6 E7X/HG 2N9K4 R90 089278<br />

4WE 6 E7X/HG24N9K4 R90 087087<br />

4WE 6 J7X/HG 2N9K4 R90 089280<br />

4WE 6 J7X/HG24N9K4 R90 08924<br />

Further st<strong>and</strong>ard types <strong>and</strong> components can be<br />

found in the EPS (st<strong>and</strong>ard price list).<br />

Material no.<br />

With rectifier<br />

24 … 240 V<br />

With indicator lamp <strong>and</strong><br />

Zener diode suppressor circuit<br />

24 V<br />

a Grey R901017010 – – –<br />

b Black R901017011 – – –<br />

a/b Black – R901017022 R901017025 R901017026<br />

Further details in<br />

clear text<br />

Seal material<br />

no code = NBR seals<br />

Caution!<br />

Observe compatibility of seal material<br />

<strong>with</strong> hydraulic fluid used!<br />

Electrical connection<br />

K4 ) = Without plug-in connector<br />

Individual connection <strong>with</strong> component plug<br />

to DIN EN 7530 -803<br />

C4 3) = Without plug-in connector<br />

Individual connection <strong>with</strong> component plugin<br />

connector C4 (Junior Timer)<br />

N9 = With concealed manual override


RE 23164/07.06 WE 6 .…H Hydraulics Bosch Rexroth AG 3/8<br />

Spool symbols<br />

A<br />

A B<br />

a b<br />

a<br />

a b<br />

b<br />

P T<br />

P T<br />

A<br />

a b = …/OF.. 1)<br />

a b<br />

P<br />

B<br />

B<br />

T<br />

A B<br />

P T<br />

a b<br />

A B<br />

a b<br />

P T<br />

A B<br />

a<br />

a b<br />

b<br />

P T<br />

= A<br />

= C<br />

= D<br />

= B<br />

= Y<br />

A B<br />

A B<br />

a 0 b<br />

a<br />

a 0 b<br />

b<br />

P T<br />

P T<br />

A B<br />

A B<br />

a 0<br />

a<br />

a 0<br />

P T<br />

P T<br />

A B<br />

P T<br />

) Only spool symbol D<br />

A B<br />

0 b 0 b<br />

P T<br />

= .A 2)<br />

= .B<br />

b<br />

= E 2)<br />

= G<br />

= H<br />

2) Example:<br />

Spool symbol E <strong>with</strong> spool position "a" ordering code ..EA..<br />

= J


4/8 Bosch Rexroth AG Hydraulics WE 6 .…H RE 23164/07.06<br />

Function, section<br />

Directional <strong>valve</strong>s of type WE are solenoid-operated <strong>directional</strong><br />

spool <strong>valve</strong>s. They control the start, stop <strong>and</strong> direction of a<br />

flow.<br />

These <strong>directional</strong> <strong>valve</strong>s basically consist of housing ( ), one<br />

or two <strong>solenoids</strong> (2), control spool (3), as well as one or two<br />

return springs (4).<br />

In the non-operated condition, control spool (3) is held by<br />

return springs (4) in the central or in the initial position. Control<br />

spool (3) is actuated via <strong>wet</strong>-<strong>pin</strong> <strong>solenoids</strong> (2).<br />

The force provided by solenoid (2) acts via plunger (5) on<br />

control spool (3) <strong>and</strong> shifts the latter from its rest position to<br />

the desired final position. This enables the required direction of<br />

flow depending on the spool symbol.<br />

5 1 3 5<br />

6 6<br />

2<br />

“a” “b”<br />

Type 4WE 6 E7X/H…<br />

A (P) B<br />

4 T<br />

4<br />

When solenoid (2) is de-energised, control spool (3) is pushed<br />

by return spring (4) back to its rest position.<br />

Manual override (6) allows control spool (3) to be shifted <strong>with</strong>out<br />

energisation of the solenoid.<br />

Note!<br />

To ensure proper operation, see to it that the pressure<br />

chamber of the solenoid is filled <strong>with</strong> oil!<br />

The manual override may only be operated using a rounded-off<br />

tool (Ø3 + mm)!<br />

Operation only up to a tank pressure of 50 bar.<br />

2


RE 23164/07.06 WE 6 .…H Hydraulics Bosch Rexroth AG 5/8<br />

Technical data (for applications outside these parameters, please consult us!)<br />

General<br />

Weight – Valve <strong>with</strong> solenoid kg approx. .25<br />

– Valve <strong>with</strong> 2 <strong>solenoids</strong> kg approx. .6<br />

Installation orientation Optional<br />

Ambient temperature range °C –30 to +50<br />

Hydraulic<br />

Maximum operating pressure – Ports A, B, P bar 3 5<br />

– Port T bar 60 With symbol A <strong>and</strong> B, port T must be used as leakage<br />

port, if the operating pressure is higher than the permissible<br />

tank pressure.<br />

Maximum flow (st<strong>and</strong>ard <strong>valve</strong>s) l/min 60<br />

Hydraulic fluid Mineral oil (HL, HLP) to DIN 5 524; fast bio-degradable<br />

hydraulic fluids to VDMA 24568 (see also RE 9022 ); HETG<br />

(rape seed oil); other hydraulic fluids on enquiry<br />

Hydraulic fluid temperature range °C –30 to +80<br />

Viscosity range mm 2 /s 2.8 to 500<br />

Max. permissible degree of contamination of the<br />

hydraulic fluid - cleanliness class to ISO 4406 (c)<br />

Electrical<br />

Class 20/ 8/ 5 )<br />

Type of voltage <strong>DC</strong> voltage<br />

Available voltages V 2; 24<br />

Voltage tolerance (nominal voltage) % ± 0<br />

Power consumption W 26<br />

Duty cycle S ( 00 %)<br />

Switching time ON ms 20 to 45<br />

OFF ms 0 to 25<br />

Maximum switching frequency /h 5000<br />

Maximum coil temperature 2) °C 50<br />

Type of protection to EN 60529 IP 65 <strong>with</strong> plug-in connector mounted <strong>and</strong> locked<br />

Insulation class VDE 0580 F<br />

) The cleanliness classes specified for components must be<br />

adhered to in hydraulic systems. Effective filtration prevents<br />

malfunction <strong>and</strong>, at the same time, prolongs the service life<br />

of components.<br />

For the selection of filters, see data sheets RE 50070,<br />

RE 50076, RE 5008 , RE 50086 <strong>and</strong> RE 50088.<br />

2) Due to the surface temperatures of solenoid coils, observe<br />

European st<strong>and</strong>ards EN 563 <strong>and</strong> EN 982!<br />

For the electrical connection, properly connect the protective<br />

conductor (PE ).


6/8 Bosch Rexroth AG Hydraulics WE 6 .…H RE 23164/07.06<br />

Characteristic curves (measured <strong>with</strong> HLP46, ϑ oil = 40 °C ± 5 °C)<br />

Pressure drop in bar →<br />

11<br />

10<br />

8<br />

6<br />

4<br />

2<br />

0 10 20 30 40 50 60<br />

Flow in l/min →<br />

300<br />

200<br />

100<br />

0 10<br />

1<br />

4<br />

20 30 40 50 60<br />

Flow in l/min →<br />

8<br />

Switching performance limits (measured <strong>with</strong> HLP46, ϑ oil = 40 °C ± 5 °C)<br />

Caution!<br />

The specified switching performance limits are valid for use<br />

<strong>with</strong> two directions of flow (e.g. from P → A <strong>and</strong> simultaneous<br />

return flow from B → T).<br />

Due to the flow forces acting <strong>with</strong>in the <strong>valve</strong>, the permissible<br />

switching performance limits may be significantly lower <strong>with</strong><br />

only one direction of flow (e.g. from P → A, while port B is<br />

blocked)!<br />

Operating pressure in bar →<br />

∆p-q V charactersistic curves<br />

7 Spool symbol “H” in central position P – T<br />

8 Spool symbol “G” in central position P – T<br />

5 6 7<br />

2<br />

3<br />

6<br />

4<br />

3<br />

7<br />

1<br />

2<br />

5<br />

Spool<br />

symbol<br />

In such a case, please consult us!<br />

Direction of flow<br />

P–A P–B A–T B–T<br />

A, B 3 3 – –<br />

C 3<br />

D, Y 4 4 3 3<br />

E 3 3<br />

J 2<br />

G 6 6 7 7<br />

H 2 5 2 2<br />

The switching performance limits were determined while<br />

the <strong>solenoids</strong> were at operating temperature, 10% undervoltage<br />

<strong>and</strong> <strong>with</strong>out tank pre-loading.<br />

<strong>DC</strong> voltage solenoid<br />

Characteristic curve Spool symbol<br />

1 A, B<br />

2 C, Y<br />

3 E<br />

4 J<br />

5 D<br />

6 G, H<br />

7 D/OF


RE 23164/07.06 WE 6 .…H Hydraulics Bosch Rexroth AG 7/8<br />

Unit dimensions: Version ”K4” (nominal dimensions in mm)<br />

5 7<br />

2<br />

4<br />

2<br />

7<br />

82,5 15<br />

7<br />

23<br />

1.1 Solenoid "a"<br />

1.2 Solenoid "b"<br />

1.1 8 10 9<br />

8 1.2<br />

13,6<br />

Ø9,4<br />

Ø5,6<br />

42<br />

85,5 (127,5)<br />

149,5<br />

A<br />

69,2<br />

P<br />

213<br />

2 Plug-in connector <strong>with</strong>out circuitry (separate order, see<br />

page 3)<br />

3 Plug-in connector <strong>with</strong> circuitry (separate order, see<br />

page 3)<br />

4 Nameplate<br />

5 Space required to remove plug-in connector<br />

6 Space required to remove coil<br />

7 Fixing nut, M T = 4 + Nm<br />

8 Plug screw for <strong>valve</strong> <strong>with</strong> one solenoid<br />

9 Identical seal rings for ports A, B, P <strong>and</strong> T<br />

10 Position of ports to DIN 24340 form A<br />

T<br />

B<br />

8,4<br />

0,01/100mm<br />

Rzmax 4<br />

Subplates to data sheet RE 45052<br />

(separate order)<br />

G 34 /0 (G /4)<br />

G 342/0 (G3/8)<br />

G 502/0 (G /2)<br />

Valve fixing screws (separate order)<br />

– 4 socket head cap screws<br />

ISO 4762 - M5 x 50 - 10.9-flZn-240h-L<br />

(friction coefficient µ total = 0.09 to 0. 4);<br />

tightening torque M T = 7 Nm ± 0%,<br />

material no. R913000064<br />

or<br />

3<br />

53<br />

45<br />

6<br />

5<br />

Required surface quality<br />

of mating surface<br />

48<br />

– 4 socket head cap screws ISO 4762 - M5 x 50 - 10.9<br />

friction coefficient µ total = 0. 2 to 0. 7, results in a<br />

tightening torque M T = 8. Nm ± 0%<br />

(to be procured by you)<br />

88,5 15


8/8 Bosch Rexroth AG Hydraulics WE 6 .…H RE 23164/07.06<br />

Unit dimensions: Version ”C4” (nominal dimensions in mm)<br />

124 15<br />

7<br />

23<br />

5<br />

7<br />

1.1 8 10 9<br />

8 1.2<br />

13,6<br />

Ø9,4<br />

Ø5,6<br />

42<br />

85,5 (127,5)<br />

149,5<br />

11<br />

Explanations of items 1 to 10,<br />

For subplates <strong>and</strong> <strong>valve</strong> fixing screws, see page 7.<br />

11 Plug-in connector ”Junior Timer”, straight (separate<br />

order, see RE 08006)<br />

12 Plug-in connector ”Junior Timer”, angled (separate<br />

order, see RE 08006)<br />

Bosch Rexroth AG<br />

Hydraulics<br />

Zum Eisengießer<br />

978 6 Lohr am Main, Germany<br />

Phone +49 (0) 93 52 / 8-0<br />

Fax +49 (0) 93 52 / 8-23 58<br />

documentation@boschrexroth.de<br />

www.boschrexroth.de<br />

A<br />

69,2<br />

P<br />

4<br />

213<br />

T<br />

B<br />

12<br />

8,4<br />

0,01/100mm<br />

Rzmax 4<br />

7<br />

Required surface quality<br />

of mating surface<br />

53<br />

45<br />

6<br />

5<br />

48<br />

86 15<br />

© This document, as well as the data, specifications <strong>and</strong> other information<br />

set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be<br />

reproduced or given to third parties <strong>with</strong>out its consent.<br />

The data specified above only serve to describe the product. No statements<br />

concerning a certain condition or suitability for a certain application<br />

can be derived from our information. The information given does not<br />

release the user from the obligation of own judgment <strong>and</strong> verification. It<br />

must be remembered that our products are subject to a natural process of<br />

wear <strong>and</strong> aging.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!