SUITE 5259 479-636-50041805 N 2ND STJOB NO.:WEL14140800-321-8721KEYNOTESREFRIGERATION NOTES15.60115.603SLOPE REFRIGERATION LINES BACKTO COMPRESSORS AT 1" PER 20' OF RUN. LOCATE HIGHESTPOINT OF REFRIGERATION LINES JUST BELOW BOTTOMCHORD OF JOIST OR BEAM. COORDINATE ELEVATION TOAVOID CONFLICTS WITH DUCTWORK,LIGHTING, ETC.AT ALL POINTS WHERE SUCTIONLINES RISE, PROVIDE A SUCTIONLINE TRAP AT THE BASE OF THERISER.1. PLAN INDICATES GENERAL ROUTING OFREFRIGERANT LINES, WITH A SINGLELINE SHOWN INDICATING BOTHSUCTION AND LIQUID LINE ROUTINGFOR EACH SYSTEM.2. REFRIGERATION SYSTEM INSTALLATIONSHALL BE IN COMPLETE CONFORMANCEWITH SPECIFICATIONS, AND WITH ALLREQUIREMENTS OF REFRIGERATIONEQUIPMENT MANUFACTURER.ROGERS, AR 72756 DESIGNED BY:INSTALL INTERMEDIATESUCTION TRAPS OUT OFCUSTOMER VIEW AT AMINIMUM OF 7'-0"AFFFOR RISERS OVER 16'-0"REFRIGERATEDCASE TYPBASE TRAPLIQUID LINETYPSUCTIONLINETYPREFRIGERANT LINESSPACED 4" OCTYP5INTERMEDIATE SUCTION LINE TRAPNTS 11.30.01 MR05LOADS MUST BEHUNG WITHIN 3"OF PANEL POINTSBOTTOM OFSTRUCTURESUCTION LINEPIPING INSULATION43"MAX1 5/8"x1 5/8" GALVANIZEDUNISTRUT P-1000, 10'-0"MAXIMUM ON CENTERSTOP BEAMCLAMP TYPNOTE: FOR OVERHEAD LINES, UNISTRUT HORIZONTAL, TRAPEZE HUNGFOR PIPING BEHIND CASES, UNISTRUT VERTICAL, WALL-MOUNTEDNYLON WIRE TIE (PAN DUIT(TYPICAL)#BT4LH-1 OR EQUIVALENT)TOP CHORD OF JOISTROOFTIGHTHORIZONTAL REFRIGERANTLINE SUPPORT DETAILNTS06/01/07 HMR03TOUNISTRUTTHREADED RODTYPSCHEDULE 40 PVC PIPEAT EACH NYLON WIRE TIE,APPROX 10" LONG (INNERDIAMETER OF PVC PIPEAPPROX. SAME AS OD OFINSULATION)LIQUID LINEPIPING INSULATIONBOLTWALL OR BUILDING STRUCTUREPVC JACKET FOR ALL REFRIGERATION LINES EXTERIOR TO BUILDING TYPPIPING INSULATION (BEYOND){ELEVATION}{PLAN}CUSH-A-CLAMP FIRMLY CLAMPED TO PIPETYP1 5/8"x1 5/8" GALVANIZED UNISTRUT P-1000, 10'-0" MAXIMUM ON CENTERS3VERTICAL REFRIGERANT LINE SUPPORTNTS 06.29.01 MR0415.60915.61015.61215.614PROVIDE PVC DRAIN LINE FROM EACHCASE DRAIN CONNECTION SAME SIZEAS CASE OUTLET, AND END OVERFLOOR DRAIN W/AIR GAP; PITCHDRAINS 1" PER 10'.PROVIDE 0.20" PVC JACKET ON ALLREFRIGERATION LINES EXTERIOR TOBUILDING.PROVIDE INTERMEDIATE SUCTIONLINE TRAP IN WALL OR VOID SPACE.INTERMEDIATE TRAP SHOULD BEPLACED AT THE MIDPOINT OF THE SUCTION LINE RISER.UTILIZE EXISTING EXTERIOR WALLOPENING AS INDICATED WHENPOSSIBLE. IF LARGER OPENING IS REQUIRED REINFORCE THEWALL AS NECESSARY, CUT THE WALL FOR THE REFRIGERATIONPIPE PENETRATION,AND SUPPLY THE PIPE PENETRATION RAIN HOOD. SEAL THE WALLOPENING WITH FOAM AS SOON AS THE PIPING THROUGH THEWALL OPENING IS COMPLETE.3. REFRIGERATION DRAWINGS AREPROVIDEDAS AN AID TO BIDDERS AND TOINDICATE DESIRED ROUTING OFREFRIGERATION LINES; CONTRACTORSHALL ASSUME FULL RESPONSIBILITYFOR CORRECT INSTALLATION OFPIPING AND ACCESSORIES TO PROVIDEA COMPLETE AND FULLY OPERATINGSYSTEM.4. PROVIDE 1/2" ARMAFLEX PIPEINSULATION ON ALL LIQUID LINES.PROVIDE 1" ARMAFLEX PIPEINSULATION ON MEDIUM TEMP.SUCTION LINES. PROVIDE 1"ARMAFLEX INSULATION ON LOW TEMP.SUCTION LINES.5. COORDINATE REFRIGERATIONDEMOLITIONISSUES WITH THE ARCHITECTURALDRAWINGS. REFER TO ARCHITECTURALPLANS FOR REFRIGERATION EQUIPMENTDEMOLITION AND COOLER REPAIR ANDREMODELING. (RE: D1 AND A1).6. REFRIGERATION SYSTEM SHALL REMAINOPERATIONAL DURING REMODELING.DURING THE PHASING OF OLD TO NEWSYSTEMS, BOTH NEW AND OLDREFRIGERATION SYSTEMS MAY BEREQUIRED TO OPERATE AT THE SAMETIME FOR A SHORT PERIOD.7. WHERE NEW REFRIGERATED EQUIPMENTISINDICATED ON THE DRAWINGS,PROVIDE DEMOLITION, REMOVAL, ANDTEMPORARY STORAGE OF OLDEQUIPMENT PER WAL-MART MECHANICALSERVICES CONSTRUCTION MANAGER'SINSTRUCTIONS, AND REFRIGERATIONDEMO NOTES ON D1 AND A1.8. PROPERLY PUMP DOWN AND RECYCLEREFRIGERANT IN EXISTINGREFRIGERATION COMPRESSOR SYSTEMSTO BE REMOVED.9. COORDINATE REMOVAL AND DISPOSAL OFEXISTING REFRIGERATION EQUIPMENT(RACKS, EVAPORATORS, CONDENSINGUNITS, CONDENSERS, AND CASES)WITH WAL-MART MECHANICAL SERVICESCONSTRUCTION MANAGER.10.-14. NOT USED.15. EXISTING REFRIGERANT PIPING MAY BERE-USED. RE. REFRIGERATIONCONSULTANTSSTIPULATION FOR REUSEISSUE BLOCKFLORENCE, KYSTORE NO. 1510195 GENERAL REMODEL14140JOB NUMBER:1 08/04/11 ADD #1SUCTION LINE(TYPICAL)REFRIGERANT SUCTION LINESSPACED 8" O.C. MOUNTED ONUNISTRUT (TYPICAL)LIQUID LINE(TYPICAL)2GR115.6033GR115.61015.6141HALLWAY215.603 15.6123GJDGGTP195415.60912' O5DMMTD-13GR115.601GROCERY SALESC15C16D11D12D10D9 D7 D5D8 D6A13B13B11B12B10B9 B7 B5B8 B6A12D13A11A10A8A9A7A63GR15GR1D13CHECKED BY:DRAWN BY:PROTO:PROTO CYCLE:DOCUMENT DATE:06/24/1108/04/11UNISTRUTMOUNTEDTO PIPECHASESTUDSD13PIPE CHASECOMPRESSOR HOUSE #2INTERMEDIATE SUCTIONLINE TRAP (PLACE TRAPAT MIDPOINT OF RISER)UNISTRUT MOUNTING FOR REFRIGERATION LINES AND ELECTRICAL CONDUITS. DO NOT MOUNT UNISTRUT TO BACK OF CASES. BOLT TO FLOOR ONLY.MEAT COOLERSTOCKROOM-GRPRINTED: 8/4/2011 8:54 AM BY: Josh Gunlock LAST SAVED: 8/4/2011 8:54 AM BY: Jdgg:\141\14140\engineering\remodel\sheetstempjdg-ai-2011-08-04\3710 - gr1 refrigeration plans and details - 1510.dwgREFRIGERATEDCASE (TYPICAL)2BASE TRAPINTERMEDIATE SUCTION%LINE TRAP DETAILNTS06/01/07 HMR05MOUNT REFRIGERATION LINESON UNISTRUT @ 8" O. C.BOLT UNISTRUT FRAME TOFLOOR ONLY @ 10' O. C.15.612D3C17C2 C4 C6 C8C1C14C13C10C3 C5 C7 C9C11D1B13B11D2B12B10B9 B7 B5B8 B6A13A12A11A10A8 A6A9 A71%FRONT REFRIGERATION PLAN1/8"=1'-0"GR1-01FNOTE: ALL WORK ON THIS SHEET IS TO BE COMPLETED BY A WAL-MART APPROVED CONTRACTOR.NOTE: REFRIGERATION CONTRACTOR IS RESPONSIBLE FOR ALL FINAL REFRIGERATION ELECTRICAL TERMINATIONS TO REFRIGERATION EQUIPMENT.SEPARATE CONTRACTOR IS RESPONSIBLEFOR RE-SKIN OF EXISTING REFRIGERATEDCASES TO REMAINEACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT THEMSELVES WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING THE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE.EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND MAY NOT REFLECT EXACT "AS-BUILT" CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS.This document originally issued and sealed byG. E. Parsons, P.E.,License #26892on 08/04/11.This document should not be considereda certified document.REFRIGERATIONPLANS ANDSHEET:DETAILSGR11


SUITE 5268 479-636-50041805 N 2ND STJOB NO.:JRC14140800-321-872107.31.09GENERAL REFRIGERATION ELECTRICAL NOTESEN061. PROVIDE ALL CONDUIT AND WIRE AS INDICATED ON DRAWING. NEATLY BUNDLE CIRCUITSAND CLEARLY TAG AND LABEL EACH CIRCUIT WITH BRANCH CIRCUIT DESIGNATION ANDREFRIGERATION SYSTEM NUMBER FOR TERMINATION BY REFRIGERATION CONTRACTOR.2. COORDINATE ALL WORK WITH REFRIGERATION CONTRACTOR PRIOR TO INSTALLATION.3. KEEP PENETRATIONS THROUGH COOLER AND FREEZER BOXES TO A MINIMUM. ROUTEALL CONDUITS SERVING FREEZERS AND COOLERS ON INSIDE OF BOX.4. UNDERSLAB CIRCUITS SHALL NOT BE ROUTED UNDER WALK-IN FREEZERS AND SHALL BEROUTED ABOVE REFRIGERANT LINES WHERE THEY CROSS.5. ON GROUPS OF THREE OR MORE REFRIGERATED CASES WITH ELECTRIC DEFROST,REFRIGERATION CONTRACTOR SHALL CONNECT CASES TO CREATE A THREE-PHASEHEATER CIRCUIT. HEATER LOADS SHALL BE BALANCED BETWEEN PHASES AS EVENLY ASPOSSIBLE (REF CASE DEFROST WIRING DETAIL).6. ROUTE REFRIGERATED CASE AND COIL FAN, LIGHTS, ANTI-SWEAT AND DEFROST BRANCHCIRCUITS TO WIREWAYS PROVIDED AT REFRIGERATION EQUIPMENT. PROVIDE ANADDITIONAL 6 FEET OF CONDUCTOR AT REFRIGERATION EQUIPMENT TO ALLOW ADEQUATELENGTH FOR TERMINATION. FINAL TERMINATION AT REFRIGERATED CASES BYREFRIGERATION CONTRACTOR.ROGERS, AR 72756 DESIGNED BY:STIPULATION FOR REUSE1 2 3REFRIGERATED CASE WIRING NOTES07.31.091. PROVIDE CONDUIT AND WIRE FOR REFRIGERATED CASE FANS, LIGHTS AND ANTI-SWEATHEATERS TO WIREWAY AT REFRIGERATION EQUIPMENT, UNLESS NOTED OTHERWISE. WIRE SIZEAS INDICATED IN SCHEDULE. FINAL TERMINATIONS AT CASE AND AT REFRIGERATIONEQUIPMENT BY R.C. REF CASE CONNECTION WIRING DETAIL.2. REFRIGERATED CASE WIRING COMPARTMENT REPRESENTED ON DRAWING BYRECTANGULAR BOX.3. CIRCUITS FOR REFRIGERATED CASES SERVED BY UNDERSLAB REFRIGERATION PIPING ARETO BE ROUTED UNDERSLAB. REFER TO CASE CONNECTION WIRING DETAIL.4. ALL UNDERSLAB CONDUITS SHALL BE 3/4" MIN.5. CIRCUITS FOR REFRIGERATED CASES SERVED BY OVERHEAD REFRIGERATION PIPING ARETO BE ROUTED DOWN FROM STRUCTURE AT THE SAME LOCATION AS THE REFRIGERATIONPIPING AND EXTENDED TO THE FIRST CASE IN EACH SYSTEM BY THE E.C. WIRE AND CONDUITFOR SLAVE WIRING BETWEEN CASES SHALL BE PROVIDED BY THE R.C.CONSULTANTSICE CREAMFREEZERDAIRYCOOLERHALLWAYJ16.470KEYNOTESFURNISH AND INSTALL NEW 20 AMP, 120 VOLT CIRCUIT(S). FEED FROM PANELBOARD AS INDICATED. PROVIDE 20A-1P CIRCUIT BREAKER IF NEEDED. EC SHALL MATCH TYPE AND AIC RATINGS OF EXISTING CIRCUIT BREAKERS. EC SHALL VERIFY PRIOR TO ROUGH-IN THAT EXISTING PANELBOARD HAS SPARE CAPACITY TO ACCOMMODATE ADDITIONAL LOAD.FLORENCE, KY1510STORE NO.195 GENERAL REMODEL14140JOB NUMBER:GROCERYFREEZER16.711POINT OF TRANSITION FROM EMT TO FLEX. PROVIDE CONDUIT ANDBRANCH CIRCUITS FOR REFRIGERATED CASE FANS, LIGHTS, ANTI-SWEATHEATERS, AND ELECTRICAL DEFROST (IF REQUIRED). TERMINATION TOREFRIGERATED CASE ELECTRICAL CONNECTION POINT BY RC. REFER TOCASE CONNECTION WIRING DETAIL.ISSUE BLOCK1 08/04/11 ADD #1H16.765EC SHALL PROVIDE CONDUIT AND FEEDERS FOR REFRIGERATED CASE FANS, LIGHTS, ANTISWEATS, RECEPTACLES, AND ELECTRIC DEFROST IF REQUIRED. TAG AND LABEL EACH CIRCUIT FOR FINAL TERMINATION BY RC. WHEN POSSIBLE ELECTRICAL CIRCUIT ROUTING SHALL FOLLOW THE REFRIGERATION LINES TO STRUCTURE.CHECKED BY:XXXXDRAWN BY:XXXPROTO:195STOCKROOM-GRPROTO CYCLE:DOCUMENT DATE:06/24/1108/04/112RE1REFRIGERATIONMECHANICAL CENTER(RMC) #2HALLWAYCH2F16.47016.765FCH2L16.470J16.765STOCKROOM-GR16.711GMTD-13ROUTE CONDUIT FOR BRANCH CIRCUITS FROM OVERHEAD THRUCHASE, ALONG WITH REFRIGERATION PIPING TYPPROVIDE (2) CONDUITS AND BRANCH CIRCUITS PER REFRIGERATEDCASE SYSTEM. ONE CONDUIT WILL SERVE 120V CASE FANS, LIGHTSAND ANTI-SWEAT CIRCUITS; ONE CONDUIT WILL SERVE 208V CASEELECTRIC DEFROST CIRCUIT. ON SYSTEMS WITHOUT ELECTRICDEFROST, ONLY PROVIDE ONE CONDUITCHASECH2LGROCERYSALESPRINTED: 8/4/2011 8:38 AM BY: Jon Channell LAST SAVED: 8/4/2011 8:37 AM BY: JRCg:\141\14140\engineering\remodel\sheetstempjrc-ai-2011-08-04\4710 - re1 refrigeration electrical plans - 1510.dwg10'-0"18"BRACKET CONDUITS TO CHASE (EVERY 10'-0" ON CENTER)PROVIDE 5' LENGTH LIQUID-TIGHT FLEXIBLE METAL CONDUIT.FURNISH APPROXIMATELY 12" PIGTAIL STUBBED FROM END OFEACH LIQUID-TIGHT FLEXIBLE METAL CONDUIT FOR TERMINATIONTO REFRIGERATED CASE ELECTRICAL CONNECTION POINT BY R.C.TYPICAL REFRIGERATED CASE SYSTEMROUTE EMT CONDUITS (UNDER CASES, ABOVESLAB) TO POINT OF TRANSITION TO FLEXBRACKET CONDUIT TO FLOORAS REQUIRED BY CODE TYPPROVIDE TRANSITION FROM EMTTO LIQUID-TIGHT FLEXIBLE METAL CONDUITBRANCH CIRCUIT CONDUITS TO OTHERREFRIGERATED CASE SYSTEMS TYP12" WIRE PIGTAILS TYP5' FLEX CONDUIT TYP2CASE CONNECTION WIRINGNTS 10.31.03 ER04FLOORCH2FMEATCOOLER1%REFRIGERATION ELECTRICAL PLAN1/8"=1'-0"FNOTE: REFRIGERATION CONTRACTOR IS RESPONSIBLE FOR ALL FINAL REFRIGERATION ELECTRICAL TERMINATIONS TO REFRIGERATION EQUIPMENT.EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT THEMSELVES WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING THE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE.This document originally issued and sealed byJason C. Adams, P.E.,License #27288on 08/04/11.This document should not be considereda certified document.XXXXXXSHEET:XX1


SUITE 5268 479-636-50041805 N 2ND STJOB NO.:JRC14140800-321-8721INPUT1234568AUXCIM-D4 SCHEDULE (E)TYPESENSORSENSORSENSORSENSORSENSORSENSORSENSORSENSORSPARECIM NOTESREFRIGERATION CIRCUITMTD-3a (E)MTD-3b (E)MTD-4a (E)MTD-4b (E)MTD-4c (E)MTD-4d (E)MTD-13 **SPARE (E)SPARE (E)06.15.09 REMC(E) - EXISTING DEVICE TO REMAIN(R) - EXISTING DEVICE TO RELOCATE AND## - MONITORING ONLY DEVICE** - FACTORY INSTALLED DEVICENOTE: ALL DEVICES NOT NOTED ARE NEW.RECONNECT1ICECREAMFREEZERGROCERYFREEZER2 3DAIRY COOLERHALLWAYJHGENERAL REFRIGERATION EMS NOTES11.19.10 EN051. EMS CONTRACTOR SHALL CONTACT THE EMS SUPPLIERTO OBTAIN A CURRENT MODULE CONFIGURATION PRINTOUTBEFORE TERMINATING SENSOR LEADS AT INPUT MODULES.THE REQUEST FOR THE CONFIGURATION PRINTOUT SHALLBE MADE PRIOR TO THE INSTALLATION OF EMS CABLES.WIRING TERMINATIONS SHALL BE LANDED ACCORDING TOTHE EMS SUPPLIER CONFIGURATION SHEETS.2. EMS CONTRACTOR SHALL PROVIDE COMPLETEDREFRIGERATION SENSOR INPUT VERIFICATION FORMS TOTHE EMS SUPPLIER AT THE BEGINNING OF THEREFRIGERATION EQUIPMENT STARTUP. EMS INSTALLERSHALL PROVIDE ASSISTANCE TO THE EMS SUPPLIER FORSPOT CHECKING OF SENSORS FOR ACCURACY.3. EMS CONTRACTOR SHALL BE PRESENT AND AVAILABLETO RESOLVE ISSUES AND PROVIDE REFRIGERATIONSTARTUP ASSISTANCE UNTIL RELEASED BY THE EMSSUPPLIER AND WAL-MART REFRIGERATION CONSTRUCTIONCOORDINATOR.4. DURING THE REFRIGERATION STARTUP, EMSCONTRACTOR SHALL COMPLETE ALL UNRESOLVEDREFRIGERATION WORK PRIOR TO WORKING ON OTHER EMSINSTALLATION ITEMS.5. WHEN THE EMS SUPPLIER IS NOT SCHEDULED TOPERFORM THE ON SITE REFRIGERATION STARTUP, THECONTRACTOR IS RESPONSIBLE FOR PERFORMING ALLCHECKS AND TEST TO ENSURE A FULLY FUNCTIONALREFRIGERATION CONTROL SYSTEM. CONTACT THE EMSSUPPLIER FOR THE BLANK TEST VERIFICATION FORMS ANDINSTRUCTIONS FOR COMPLETING. ALL COMPLETED TESTVERIFICATION FORMS SHALL BE RETURNED TO THEWALMART MECHANICAL SERVICES CONSTRUCTIONMANAGER.6. REFER TO ARCHITECTURAL DRAWINGS FOR PIPINGINSTALLATION AND SEALING REQUIREMENTS FOR DEVICESSHOWN ON COOLER/FREEZER PANELS. DO NOT INSTALLPIPING WITHIN COOLER/FREEZER PANELS.7. ROUTE ALL UTILITY SERVICE LINES (PIPES AND CONDUIT)WITHIN STUD WALLS WHEREVER POSSIBLE. ONCOOLER/FREEZER PANELS IN FOOD PREP AREAS WHEREUTILITIES MUST BE EXPOSED, CONTRACTOR TO HAVE THEOPTION OF THE FOLLOWING:STIPULATION FOR REUSECONSULTANTSROGERS, AR 72756 DESIGNED BY:RISER DIAGRAM LEGENDNEW EQUIPMENTEXISTING EQUIPMENTEQUIPMENT TO BE DEMOLISHEDNOTE:ALL OF THE ELECTRICAL DEVICES SHOWN ON THERISER DIAGRAM AS EXISTING ARE BASED UPONAS-BUILT DRAWINGS. EC SHALL VERIFY THE EXACTEXISTING CONDITIONS, SIZES AND LOCATIONS OFEQUIPMENT PRIOR TO ROUGH-IN. THIS RISER ISSHOWN FOR INFORMATIONAL PURPOSES ONLY ANDANY NEW DEVICES ARE SHOWN IN BOLD AND ARENOTED. DURING CONSTRUCTION, THE STORESHALL STAY OPEN FOR BUSINESS. ANYNECESSARY POWER DOWNTIME SHALL BESCHEDULED AND APPROVED BY GENERALCONTRACTOR AND WALMART CONSTRUCTIONPROVIDE CONDUIT, FITTINGS, WIRE-TIES, CONNECTORS, LABELS, AND ANY OTHER MISC. PARTS NEEDED TO INSTALL AND START THE SYSTEM.OWNER WILL FURNISH ALL MAJOR E.M.S. DEVICES (INCLUDING 24 VOLT TRANSFORMERS, RELAYS).CIM ONE-LINE REFLECTS THE INTENDEDDESIGN BASED ON NEW CASES ANDEXISTING SYSTEM NUMBERS.VERIFY ALL EXISTING CONDITIONSAND LOCATION OF ALL EMS EQUIPMENTPRIOR TO ROUGH-IN.WIRE LEGENDWIR-1010 (TAN CABLE 18-2, 20-2 TWISTED PAIR)WIR-2020 (BLUE CABLE 22-2 TWISTED PAIR)NOTE: ALL EMS CABLES FURNISHED BY OWNER FOR INSTALLATION BY EMS CONTRACTOR. ALL CABLE WIR-2020 UNLESS NOTED OTHERWISE.NOTE: ALL EXISTING DEVICES ARE TO REMAIN UNLESS NOTED OTHERWISE AND ARE SHOWN FOR CLARITY OF EMS DESIGNSTOCKROOM-GRREFRIGERATION MECHANICAL CENTER (RMC) #2RACK D CONTROLLERRACK C CONTROLLERHALLWAY2REM1REARCIMBOARDSMTD-13GA. SURFACE MOUNT UTILITIES WITH NON-CORROSIVEANCHORS; SEAL BOTH SIDES OF PIPE/CONDUIT TO PANELCONTINUOUSLY WITH SEALANT.B. INSTALL UTILITIES 1/2" OFF FACE OF PANEL TO ALLOWFOR CLEANING; USE ONLY NON-CORROSIVE MATERIALS FORSPACERS AND ANCHORS.C. COVER UTILITIES WITH 20 GAUGE STAINLESS STEELBENT PLATES MOUNTED TO WALL WITH NON-CORROSIVEANCHORS; APPLY CONTINUOUS SEALANT ALONG EDGES07.31.09 ES10LTA-XRC2-XERIMROMCIMDISRIBREM SYMBOLSREFRIGERATION CIRCUITREFRIGERATION RACK CONTROLLERRACK INPUT MODULERACK OUTPUT MODULECASE INPUT MODULEDIGITAL INPUT SWITCH (DUAL-TEMP)RELAY IN A BOXFLORENCE, KYSTORE NO. 1510195 GENERAL REMODEL14140JOB NUMBER:RACK "A"CONTROLLERRACK "B"CONTROLLERRACK "C"CONTROLLERRACK "D"CONTROLLERREFRIGERATION MECHANICAL CENTER (RMC) #1MEAT COOLERFSCASE/COIL TEMPERATURE MODULEISSUE BLOCK1 08/04/11 ADD #1CIMA1 (E)CIMB1 (E)CIMC1 (E)CIMD1 (E)RACK B CONTROLLERSEAFOODCOOLERSEAFOODCIMA2 (E)CIMB2 (E)CIMC2 (E)CIMD2 (E)E.4GROCERYSALESRACK A CONTROLLERCIMA3 (E)CIMB3 (E)CIMC3 (E)CIMD3 (E)CIMA4 (E)CIMB4 (E)CIMC4 (E)CIMD4 (E)STEMPERATURE SENSOR (TYP)- SEE CIM SCHEDULEECHECKED BY:DRAWN BY:PROTO:XXXXXXX195CIMA5 (E)CIMB5 (E)CIMC5 (E)WIR-2020 (TYP)PROTO CYCLE:DOCUMENT DATE:06/24/1108/04/11D.5CIMA6 (E)CIMB6 (E)CIMC6 (E)D3%PARTIAL REFRIGERATION EMS ONE-LINE DIAGRAMNTSEDC4C.5PRODUCEPREP2REM1FRONTCIMBOARDCPRINTED: 8/4/2011 8:38 AM BY: Jon Channell LAST SAVED: 8/4/2011 8:37 AM BY: JRCg:\141\14140\engineering\remodel\sheetstempjrc-ai-2011-08-04\4751 - rem1 refrigeration energy management plan - 1510.dwgCONDUITCIM-A1CIM-A2CIM-B6CIM-C1CIM-C2CIM-C3CIM-C4CIM-C6CIM-D1CONDUITEXISTING DUAL TEMP SWITCH, TYPCIM-A3CIM-A4CIM-A5CIM-A6CIM-B1CIM-B2CIM-B3CIM-B4CIM-B5CIM-C5CIM-D2CIM-D3CIM-D4FRONT CIM BOARDREAR CIM BOARDPLYWOOD BACK PANELPLYWOOD BACK PANELIN EDC4IN STOCKROOM-GR2%EXISTING CIM BACKBOARDSCONDUITPRODUCECOOLERBAKERYUTILITYBAKERYBAKERYCOOLER1.5 2.2SERVICE DELIBAKERY & DELIFREEZERDELI DELI2.5COOLER UTILITY3.41%REFRIGERATION ENERGY MANAGEMENT PLAN1/16"=1'-0"DELIPREPB.6BNOTE: ALL WORK ON THIS SHEET IS TO BE COMPLETED BY WALMART APPROVED CONTRACTOR.EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT THEMSELVES WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING THE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE.This document originally issued and sealed byJason C. Adams, P.E.,License #27288on 08/04/11.This document should not be considereda certified document.XXXXXXSHEET:XX1


CONSULTANTS STIPULATION FOR REUSE930 CENTRAL - KANSAS CITY, MISSOURI 64105Copyright 2011 Johnston Burkholder AssociatescOUTSIDE FACE OF END FRAME12 GA STL ANCHOR PL (BY SUPPLIER) TYP AT EACH ENDANCHOR BOLTS: (1) 3/8" DIAPOWERS WEDGE BOLT+, REF 3-FXS2.hnom = 2 1/8", ho = 2 3/4", (UNO).ANCHOR AT DEEP2'-0" 4'-0"EXISTING WALL STUDSWOOD BLOCKINGBOLT ALL UPRIGHTS TO WALL, REF GONDOLA UPRIGHT ANCHORAGE AT WALLGONDOLA UPRIGHT FRAME,REF PLAN{WOOD BLOCKING AT EXISTING STUD WALLS}1 1{GONDOLA UPRIGHTANCHORAGE AT WALL}BOLT ALL (NON-SUPER DUTY) UPRIGHTS TO WALL AT 6'-0" AFF. USE (1) 3/8"x5" LARGE DIAMETER TAPCON (LDT-3850) CONCRETE SCREW AT CMU OR 1/4"X6" LAG SCREW WITH 1/2" DIA WASHER AT STUD WALLS. INSTALLED BY GCGONDOLA UPRIGHT FRAME,REF FINAL MERCHANDISE PLANGONDOLAS PROVIDED BY WALMART. GONDOLA ANCHORING FURNISHED BY WALMART AND INSTALLED BY GC.METHOD OF BOLTING WILL VARY DUE TO DIFFERENT EXISTING WALL MATERIALS.REF1-FXS2REF 1-FXS2 FOR BASE ANCHORAGE (INSTALLED BY GC)BASE DECK SHELVING REMOVED FOR CLARITYNOTE:HALF GONDOLAS SHALL BE ANCHORED TO WALL ASSHOWN TO SATISFY OWNER REQUIREMENTS. WALLANCHORAGE IS NOT REQUIRED FOR SEISMIC DESIGNOR CODE COMPLIANCE.INSTALLATION NOTES:1. GAPS BETWEEN SHELVESSHALL NOT EXCEED 5/8".2. UPRIGHT DEFLECTIONSHALL NOT EXCEED 1 3/8"IN A HORIZONTAL PLANE.3. SHELVES SHALL NOTSLOPE DOWN TO THEFRONT DUE TO UPRIGHTDEFLECTION.4. SHELVES ABOVE BASEDECK SHELVING LEVELSHALL NOT EXTENDBEYOND BASE DECKSHELVING AT ANY TIME.5. EXTENDERS SHALL NOTBEUSED ON ANY HALFGONDOLA THAT WILLCREATE A HEIGHTOF 72" OR TALLER UNLESSIT IS ANCHORED TO THEWALL. ALL HALF GONDOLAS72" OR TALLER MUST BEANCHORED TO THE WALLAT 72" AFF, REF GONDOLAUPRIGHT ANCHORAGE AT5/8" DIA, TYP{}"MINCL POSTEQ3{}"MINBYEQRACKSUPPLIER{}"MINBASE PLATE AND FRAME BY RACK SUPPLIER{}"MINBYRACKSUPPLIERANCHOR BOLTS: (1) 1/2" DIAPOWERS WEDGE BOLT+, REF 3-FXS2.hnom = 2 1/2", ho = 3", (UNO).NOTES:1. PROVIDE SIZE AND QUANTITY OF ANCHORS AS NOTED ATEACH RACK UPRIGHT FOR TOTAL ANCHORAGEREQUIREMENT. ADDITIONAL HOLES IN BASE PLATE NEED NOTBE FILLED WITH ANCHORS. PLACE ANCHORS AT ROWCLOSEST TO RACK UPRIGHT WHEN BASE PLATE CONTAINSGREATER NUMBER OF BOLT HOLES.2. PROVIDE WASHERS AS REQUIRED TO ESTABLISH REQUIREDEMBEDMENT DEPTH, "hnom".TYPICAL ANCHORISSUE BLOCKFLORENCE, KYSTORE NO. 1510JOB NUMBER: 141401 08/04/11 ADD #1195 GENERAL REMODELEND CAP FRAMES1 1/2"=1'-0" 7-336ANCHOR AT HALF GONDOLA UPRIGHTN.T.S. 7-325AT RACK FRAMES1 1/2"=1'-0" 7-078/5/2011 12:08:04 PM 8/5/2011 12:08:23 PMS:\4-WALMART STORAGE RACKS\2011 PROJECTS\SN-1000\1510 - FLORENCE, KY (BCH)\DRAWINGS\5020 - FXS2 RACK AND SHELVING ANCHORAGE DETAILS - 1510DH4{SECTION AT} {END FRAME}3{}"MIN{SECTION AT} {INTERIOR FRAME}OUTSIDE FACE OF END FRAMELIGHT GAUGE STEEL STRAP(22 GA MIN THICKNESS)(BY WALMART AND INSTALLED BY GC)REF 1-FXS2 FOR PLACEMENT OF STRAPSANCHOR BOLTS: (1) 3/8" DIAPOWERS WEDGE BOLT+, REF 3-FXS2.hnom = 2 1/8", ho = 2 3/4", (UNO).LIGHT GAUGE STEEL STRAP(22 GA MIN THICKNESS)(BY WALMART AND INSTALLED BY GC)REF 1-FXS2 FOR PLACEMENT OF STRAPSANCHOR BOLTS: (2) 3/8" DIAPOWERS WEDGE BOLT+, REF 3-FXS2.hnom = 2 1/8", ho = 2 3/4", (UNO).TYPICAL ANCHORAT GONDOLA FRAMES1 1/2"=1'-0" 7-06Lathnom3hot - PL THICKNESShnom - EMBEDMENT DEPTHho - MIN HOLE DEPTHLa - LENGTH OF ANCHORALL ANCHOR BOLTS SHALL BE POWERS WEDGE BOLT+. INSTALL PER ICCESR-2526. REF BASE PLATE DETAIL FOR DIAMETER AND EMBEDMENT. REFSHEET FXS1 FOR SPECIAL INSPECTION REQUIREMENTS WITH CONCRETEANCHOR BOLT.ACCEPTABLE ALTERNATE ANCHOR TYPES ARE;1) SIMPSON STRONG TIE TITEN HD SCREW ANCHOR,INSTALL PER ICC ESR-27132) HILTI KWIK HUS-EZ SCREW ANCHOR,INSTALL PER ICC ESR-3027USING SAME QUANTITY, SIZE AND EMBEDMENT DEPTH NOTED IN ANCHORDETAILS.NOTE:IF CENTERLINE OF ANCHOR BOLTS FALLS WITHIN 1" OF CONTROLJOINT, SHIFT FIXTURE 2" (MAX) PERPENDICULAR TO THE JOINT,OTHERWISE SUBMIT RFI TO THE ARCHITECT FOR ALTERNATEINSTALLATION BEFORE INSTALLING BOLTS.ANCHOR BOLT DETAILNTS 7-0525-FXS2AT EACHFRAME,BYVARIESSUPPLIERREF SCHEDULEBY SUPPLIER{PLAN VIEW}BY SUPPLIER{ELEVATION}SHELVING LAYOUT VARIESRACK BRACING BY SUPPLERSTORAGE AREA RACK ELEVATIONS3/16"=1'-0" 7-03BYSUPPLIER{SIDE VIEW}1VARIES1REF SCHEDULEVARIES{GONDOLA FRONT VIEW}END OFFRAME-TYPEACH SIDEEXIST WALLOR FIXTUREFRAMECL OFANCHORBOLTSTYPGONDOLA SHELVING BY SUPPLIER4"(INTERIOR)4-FXS2(END)4-FXS2{1/2GONDOLAVARIESTYP4-FXS2{1/2 GONDOLASIDE VIEW AT WALLOR FIXTURE FRAME}2 1/2"MIN6 1/2"MAXAT 24" GONDOLAANCHOR STRAP BY WALMARTGONDOLASHELVESABOVEGONDOLAUPRIGHTFRAME, TYPANCHOR STRAP BY WALMARTEXISTING WALL OR FIXTURE FRAMEREF 6-FXS2 FOR UPRIGHT POST CONNECTION TO EXIST WALL PER OWNER REQUIREMENTSTYPICAL GONDOLA AND DEEP END CAP SHELVING ELEVATIONS3/8"=1'-0" 7-014'-0"4'-0"ANCHOR STRAP BY WALMARTTYPTYPANCHOR SPACING = 8'-0" MAX (UNO)REF PLAN{DEEP END CAPPLAN VIEW}VARIES{DEEP END CAPSIDE VIEW}TYP7-FXS2TYPANCHOR PL BY SUPPLIER, TYPGONDOLA SHELVING BY SUPPLIERTYP7-FXS2VARIESREF SCHEDULECHECKED BY:DRAWN BY:PROTO:PROTO CYCLE:DOCUMENT DATE:RACK ANDSHELVINGANCHORAGEDETAILSSHEET:FXS2BJHDDW19502/25/1107/08/11JBA PROJ#: 1035101510