27.07.2013 Views

Real-Time PCRs anvendelse til diagnostik af endometritis - Elbo

Real-Time PCRs anvendelse til diagnostik af endometritis - Elbo

Real-Time PCRs anvendelse til diagnostik af endometritis - Elbo

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Sammendrag<br />

Formålet med undersøgelsen var at evaluere den diagnostiske styrke <strong>af</strong><br />

<strong>Real</strong>-<strong>Time</strong> Polymerase Chain Reaction (<strong>Real</strong>-<strong>Time</strong> PCR) <strong>til</strong> direkte påvisning<br />

<strong>af</strong> Streptococcus equi subspecies zooepidemicus og Streptococcus<br />

equi subspecies equi fra prøvemateriale fra hoppers endometrium uden en<br />

forudgående bakteriologisk dyrkning (BU).<br />

Prøvematerialet bestod <strong>af</strong> 53 sæt prøver <strong>af</strong> følgende: En endometriesvaberprøve,<br />

en lav-volumen uterusskylleprøve og en endometriebiopsi. Prøverne<br />

var udtaget parrede, hvilket muliggjorde sammenligning <strong>af</strong> prøvetyperne<br />

indenfor og imellem hopperne. Samtlige 159 prøver blev undersøgt for<br />

<strong>til</strong>stedeværelse <strong>af</strong> Streptococcus equi subspecies zooepidemicus og Streptococcus<br />

equi subspecies equi, ved hjælp <strong>af</strong> SYBR ® Green <strong>Real</strong>-<strong>Time</strong> PCR og et<br />

primersæt specifikt for det bakterielle superoxid dismutase A gen, sodA.<br />

Resultaterne viste 34 % positive svaberprøver, 38 % positive skylleprøver<br />

og 15 % positive biopsier. Til sammenligning var resultaterne for BU 17 %<br />

positive svaberprøver, 28 % positive skylleprøver og 15 % positive biopsier.<br />

Korrelation mellem <strong>Real</strong>-<strong>Time</strong> PCR og BU positive resultater var lav, hvilket<br />

gav sensitiviteter på mellem 0,25 - 0,56.<br />

Det kan konkluderes, at <strong>Real</strong>-<strong>Time</strong> PCR forøgede andelen <strong>af</strong> positive svaberprøver<br />

statistisk signifikant (p = 0,05) sammenlignet med BU. Andelen <strong>af</strong><br />

positive skylleprøver blev numerisk, men ikke signifikant øget. Andelen <strong>af</strong><br />

positive prøver var statistisk signifikant lavere for biopsier sammenlignet med<br />

de øvrige prøvetyper u<strong>af</strong>hængigt <strong>af</strong> påvisningsmetoden.<br />

Summary<br />

The aim was to investigate the diagnostic performance of <strong>Real</strong>-<strong>Time</strong> Polymerase<br />

Chain Reaction (<strong>Real</strong>-<strong>Time</strong> PCR) for direct detection of Streptococcus<br />

equi subspecies zooepidemicus and Streptococcus equi subspecies<br />

equi from sample material from mare endometrium without prior bacteriological<br />

culturing (BC).<br />

The sample material consisted of 53 sets of samples as follows, an<br />

endometrial swab, a low-volume uterine flush and an endometrial biopsy.<br />

The paired sampling enabled comparison of the different types of samples<br />

within and between mares.<br />

All 159 samples were examined for the presence of Streptococcus equi<br />

subspecies zooepidemicus and Streptococcus equi subspecies equi by<br />

means of SYBR ® Green <strong>Real</strong>-<strong>Time</strong> PCR and primers specific for the bacterial<br />

superoxide dismutase gene, sodA.<br />

The results showed that 34 % of the swabs, 38 % uterine flushes and 15<br />

% of the biopsies were positive. In comparison the results from BC of<br />

swabs, uterine flushes and biopsies were 17 %, 28 % and 15 % respectively.<br />

The correlation between <strong>Real</strong>-<strong>Time</strong> PCR positive results and BC positive<br />

results were low, and sensitivities ranged from 0.25–0.56.<br />

The <strong>Real</strong>-<strong>Time</strong> PCR resulted in statistically significant (p = 0.05)<br />

increased number of positive swabs compared to BC. The number of positive<br />

uterine flushes was numerically but not significantly higher. On the<br />

biopsy material the number of positive samples was statistical significantly<br />

lower compared to the other types of samples independent of test<br />

method.<br />

bOLETTE SKIvE1 MORTEN RøNN PETERSEN2 ANDERS MIKI bOJESEN3 1DYRLÆGE, RÄvEKULLEvÄGEN 10,<br />

423 72 SÄvE, GÖTEbORG, SvERIGE<br />

2DYRLÆGE, PH.D., INSTITUT FOR<br />

PRODUKTIONSDYR OG HESTE/<br />

FAGGRUPPEN FOR REPRODUKTION OG<br />

ObSTETRIK, DET bIOvIDENSKAbELIGE<br />

FAKULTET vED KøbENHAvNS<br />

UNIvERSITET, LIFE KU<br />

3DYRLÆGE, PH.D, LEKTOR, INSTITUT<br />

FOR vETERIÆR SYGDOMSbIOLOGI/<br />

FAGGRUPPEN FOR MIKRObIOLOGI,<br />

DET bIOvIDENSKAbELIGE FAKULTET vED<br />

KøbENHAvNS UNIvERSITET, LIFE KU<br />

Indledning<br />

Bakteriel <strong>endometritis</strong> udgør et problem<br />

både for hesteavlen som industri og for<br />

den private hoppeejer. Lidelsen er anerkendt<br />

som en vigtig årsag <strong>til</strong> subfer<strong>til</strong>itet<br />

eller infer<strong>til</strong>itet hos hopper (1,2). Diagnosen<br />

s<strong>til</strong>les på baggrund <strong>af</strong> anamnese, kliniske<br />

tegn/undersøgelse og dyrkning <strong>af</strong><br />

prøvemateriale fra hoppens endometrium<br />

på blodagarplader ofte suppleret med en<br />

udstrygning <strong>af</strong> prøvemateriale <strong>til</strong> evaluering<br />

<strong>af</strong> cytologi for at bekræfte eller<br />

<strong>af</strong>kræfte et inflammatorisk respons (2-7).<br />

Escherichia coli (E. coli) og ß-hæmolytiske<br />

streptokokker er de hyppigst isolerede<br />

bakterier fra patologiske <strong>til</strong>stande i uterus<br />

(1,6), hvor det dominerende agens er<br />

Streptococcus equi subspecies zooepidemicus<br />

(1,8).<br />

Dyrkningsbaserede undersøgelser er<br />

tidskrævende, og resultaterne er ikke altid<br />

entydige. Der er <strong>til</strong>fælde <strong>af</strong> falsk negative,<br />

især blandt kronisk inficerede hopper (2,<br />

5). Det er derfor interessant at undersøge,<br />

om en molekylærbiologisk metode som<br />

<strong>Real</strong>-<strong>Time</strong> Polymerase Chain Reaction<br />

(<strong>Real</strong>-<strong>Time</strong> PCR) kan bruges <strong>til</strong> at påvise<br />

Streptococcus equi subspecies zooepidemicus<br />

og Streptococcus equi subspecies<br />

equi direkte fra klinisk prøvemateriale for<br />

derved at øge sensitiviteten, specificiteten<br />

og hastigheden, hvormed agens kan<br />

DVT 01 2012 21<br />

>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!