Installation Manual
Photovoltaic modules types
IBC Module Transparent xxx ES-TA1
IBC MonoSol xxx GS10-HC-N
IBC Module Bifacial xxx LS-TA1
IBC Module Transparent xxx LS-TA2
IBC Module White xxx MS-TA1
IBC Module Black xxx MS-TA1
As of: 19.11.2024
Safety, installation and instruction manual
Corresponds to safety requirements in accordance with IEC 61730; not UL
certified
ELETRICAL SYSTEM – PLEASE CONTACT YOUR INSTALLER
Photovoltaic modules (PV/solar modules) produce direct current under light
irradiation. This installation guide contains important information on safety,
installation and operation of the modules, which you need to know before using
the modules.
Table of contents
1. General Information .................................................................................................................... 3
2. Safety Instructions ..................................................................................................................... 5
2.1 Important general information and standards ............................................................................................................................................ 5
2.2 Safety guidelines for handling modules ........................................................................................................................................................ 5
2.3 Safety measures during installation ................................................................................................................................................................. 6
3. Installation ...................................................................................................................................... 8
3.1 Electrical installation ................................................................................................................................................................................................... 8
3.1.1 Maximum number of modules in series / parallel strings ............................................................................................................................................... 9
3.2 Grounding ...................................................................................................................................................................................................................... 10
3.3 Mechanical installation .......................................................................................................................................................................................... 10
3.4 Assembly variants ...................................................................................................................................................................................................... 13
3.4.1 Clamping short and long frame side ........................................................................................................................................................................................ 13
3.4.2 Insertion systems for long and short side ............................................................................................................................................................................ 15
3.4.3 IBC AeroFix G3 mounting system ............................................................................................................................................................................................. 16
4. Maintenance ................................................................................................................................ 17
5. Cleaning the modules .............................................................................................................. 17
6. Transport and storage ............................................................................................................. 18
7. Disposal .......................................................................................................................................... 18
8. Disclaimer ...................................................................................................................................... 19
IAED-V241119 Page 2 from 20
1. General Information
With IBC SOLAR AG solar modules, you have purchased a high-quality product. To ensure that you can enjoy your new modules
in the long term without restriction, please read this installation guide thoroughly and carefully and take note of all instructions
before you start installing, wiring, operating, servicing or transporting the modules.
Before you attempt to install, wire, operate or service the modules, please make sure that you have read and understood
all the safety information in this installation guide.
The solar modules must be installed and operated in accordance with the generally recognised technical regulations.
During assembly, the relevant national guidelines on health and safety and accident prevention must be observed and
adhered to. This particularly applies to work on the roof.
Please observe all local, regional, national and international legal provisions, guidelines, standards and regulations, as
well as the guidelines on work safety from the employer's liability insurance associations.
Assembly, installation and initial operation can only be carried out by licensed and qualified professionals.
Appropriate safety measures (e.g. fall protection devices) must be used for work on solar generators, particularly on
roofs.
The solar module must be checked for mechanical integrity before installation. Damaged solar modules (e.g. modules
with broken glass or damage to the insulating foil on the back cannot be installed. Damage to the insulating foil on the
back can have serious consequences (e.g. delamination, damage to health and danger of death).
The modules then also produce voltage when they are not connected to an electric current or load resistor. Even with a
light irradiation of only 5% of full sunlight, the modules produce almost full voltage. Current intensity and output
increase with light intensity.
The output power produced by the modules can be above the specified nominal power.
The industry standard nominal values are calculated at 1000 W/m² radiation intensity and a 25 °C solar cell temperature.
Colder temperatures can cause a sharp increase in voltage and power.
Make sure that the modules are only exposed to ambient temperatures of −40° to +85 °C.
The current intensity, voltage and resulting power produced by the module can increase as a result of reflection from
snow, water or other reflective surfaces.
Avoid focussing light and directing it onto the module. Even at the lowest level of illumination the full open circuit
voltage of the modules is to be expected, i.e. caution must always be exercised during installation with regard to
electrical faults e.g. short circuits.
The modules are intended for operation solely in open air and on solid ground. They are not for operation/use in indoor
spaces or on mobile products of any kind.
They are also not designed for operation or use in hazardous areas. These include, in particular, installations where the
modules may come into contact with saltwater or where they could be partially or fully immersed in freshwater or
saltwater e.g. on boats or buoys. The distance to the coast must be minimum 500 m. (For distances less than 500m,
please contact IBC SOLAR AG)
Only use devices, connectors, cables and elevated installations which are suitable for use with photovoltaic systems.
Please observe all safety measures and instructions for other components used.
IAED-V241119 Page 3 from 20
For even short-term storage of modules that are not connected together outdoors, modules that are placed with the
glass side downwards must be covered. This prevents water collection on the module and protects exposed connectors
from damage.
IAED-V241119 Page 4 from 20
2. Safety Instructions
In order to prevent injury or damage to the solar modules in all circumstances, it is essential that you observe the following
safety instructions.
2.1 Important general information and standards
The entire PV system must be mounted according to the generally recognised technical regulations. Please observe the
accident prevention regulations that are in force in the country where the solar modules are to be used.
Please observe all regulations and guidelines under public law during planning, erection, operation and maintenance of gridconnected
PV plants including the following: national standards, technical connection conditions, accident prevention
regulations, the relevant valid guidelines from the association of property insurers, the trade guidelines of the roofing association
(Fachregeln des Deutschen Dachdeckerhandwerks) and all other relevant general guidelines.
Changes that are not permitted and improper use of our components during installation and construction may result in any
liability claim lapsing.
The solar modules are certified in accordance with IEC 61215 and IEC 61730 (protection class II)!
2.2 Safety guidelines for handling modules
Always handle your solar modules with care to prevent damage. In particular, do not tread on the module. Do not let it
drop and protect it from falling objects.
Solar modules must not be kept or transported on the connection cable or socket.
Use a glass suction cup to remove and transport a module or hold the module solely by the module frame. Transport the
module vertically over longer distances.
Take care not to damage or scratch the back of the modules and do not set a module down heavily on a surface. Take
particular care when the module is on an edge.
Do not disassemble, change or adapt the module or remove any IBC SOLAR AG fitted part or label without the consent
of IBC SOLAR, otherwise guarantee claims will become invalid.
Do not weld, drill or insert nails into the module frame. Do not drill holes into the glass surface of the module. If you do,
your guarantee claim will expire. Do not apply paint or glue to the module.
Never leave the module unsecured or without a bracket.
Modules with a broken glass surface or a rip in the rear side foil are irreparably damaged and must not be used under
any circumstances, as any contact with the module surface or elevation can cause an electric shock. Broken or
damaged modules must be handled carefully and disposed of properly. Broken glass can have sharp edges and cause
injury if it is not handled using suitable protective equipment.
Only work in a dry environment using dry tools. Only work with the modules when they are fully dry, unless you have
suitable protective equipment.
Do not stack the modules on top of one another to avoid damage.
IAED-V241119 Page 5 from 20
Protect the plug contacts from dirt as much as possible, or use appropriate cleaning measures on the contacts if they
come into contact with dirt.
Always wear gloves when installing modules to guarantee your own safety and to protect the modules from
contamination (particularly for modules with ARC glass).
2.3 Safety measures during installation
During installation, ensure that no children or unauthorised persons come near the system or modules. Do not carry out
installation work if there are strong winds.
Before installation, check junction box, cables and connectors for damage and dirt. Do not install damaged PV modules
or PV modules with dirty connectors.
If the modules are not installed at ground level, take the appropriate safety precautions and use suitable protective
devices to avoid damage from falling modules and other safety risks.
Photovoltaic modules do not have an on/off switch. They can only be taken out of operation by removing light
irradation. To do this, you should either cover the front surface with a towel, box or other fully opaque material or turn
the front surface downwards on a smooth, flat surface.
Disconnecting from direct current conductors can cause electric arcs. It is therefore essential that you disconnect the
inverter from the alternating voltage grid before the start of any work on photovoltaic systems, particularly before
disconnecting connectors in direct current circuits.
If you work with modules that are exposed to light, please observe all legal requirements and regulations for working
with electrical systems and live electrical equipment. Please also be aware that through the serial connection of
modules the low voltage range (< 120 V DC) can be considerably exceeded. Please be particularly cautious.
During installation and while the module is exposed to light, avoid touching the electric terminals or cable ends.
The solar modules, particularly the connectors and tools, must be dry during installation.
Do not wear any jewellery or accessories made of metal whilst performing mechanical or electrical installation work.
Furthermore, do not insert electrically conducting parts into any of the sockets.
Never interrupt electrical connections or pull out connectors while the circuit is live.
Touching electrically charged module parts such as terminals can cause burns, sparks and electric shocks and can be
fatal. This applies even if the module is not connected.
Only use insulated tools and wear rubber gloves that are recommended for electrical installation work.
Avoid loading the module cable mechanically, covering drainage holes or allowing water to run in the direction of the
plug connectors.
If necessary, please take suitable lightning protection measures in accordance with country-specific standards and
regulations. If the building has a lightning protection system then the module frame and assembly system must be
integrated into the external lightning protection and if necessary, surge protection devices should also be installed.
Please get in touch with a lightning protection specialist for this.
Please find out about fire protection guidelines and requirements for houses and buildings from the local authorities.
Construction and mounting on roofs can affect the fire safety of a building. Any faults in these areas can be hazardous
in case of fire.
IAED-V241119 Page 6 from 20
When mounting on the roof, modules should be installed on a fireproof coating (or surface) approved for this purpose.
In some circumstances, components such as fault current protection switches, cutout switches and circuit breakers may
be required.
Do not use the modules close to devices or areas where gas is produced or can accumulate. Solar modules must not be
installed close to highly flammable substances or vapours. Solar modules are not explosion-protected equipment.
IBC SOLAR AG solar modules are classified as construction products as defined by the DIBt (German institute for
building technology). The requirements from the current building regulation list (BRL) must be taken into account.
IAED-V241119 Page 7 from 20
3. Installation
3.1 Electrical installation
Take all necessary precautions during installation, operation and servicing of the modules to avoid electrical hazards.
Make sure that all electrical connections are securely closed.
If the direct voltage of the entire system exceeds 100 V, the installation, operation and maintenance must be performed
by a licensed electrician, unless the local regulations for handling electrical systems specify otherwise.
Contact with a direct voltage of 30 V or more is potentially dangerous.
Do not use modules with different electrical or physical configurations within the same system. Only identical solar
modules of the same type and performance class can be connected.
The maximum open circuit voltage of the system must not exceed the maximum system voltage of the module.
All IBC SOLAR AG modules are provided with connection cables and connectors ex-works. Thanks to their construction
style, they can easily be installed in series.
During assembly, beware of tensile force relief on the module connection cable.
IBC SOLAR AG modules are equipped with Multi-Contact® type 4 clickable connectors for system voltages up to
1000V and with Multi-Contact® type EVO2 and EVO2A for system voltages up to 1500 V.
The PV module's connector plug Multi-Contact® type 4 can also be protected with the PV-SSH4 connecting safety
locking clip available from Multi-Contact®. The factory installed solar connectors and connection cables must not be
removed. Currently there is no locking clip available for the Multi-Contact® type EVO2 and EVO2A.
The PV-SSH4 clip is not provided by IBC SOLAR AG and must be purchased separately. If the locking clip is installed,
the PV module connector plug can only be unlocked with the PV-MS tool, which is also available from Multi-Contact®.
As a manufacturer, Stäubli guarantees interconnectivity and pluggability within the Stäubli Multi-Contact® connector
family taking into account the system voltage up to 1000 V. They also guarantees interconnectivity and pluggability for
the Stäubli Multi-Contact® connector EVO2 and EVO2A.
During system cabling, please pay attention to the correct cross-sections and connections permitted for the maximum
short-circuit current intensity of the module. The cable must have a minimum cross-section of 4mm² and the isolation
must be permitted for the maximum system voltage.
The bending radius of the cable must be at least five times of the outside cable diameter.
Only cables suitable for external assembly should be used for connecting module strings.
The cables must be protected from damage.
The socket, cable and connector must not be moistened or cleaned with oily, greasy or alcohol-based substances.
Please ensure that you match the correct polarity of the cable and terminals when making connections. Otherwise there
is a risk that the module will become damaged.
If modules are connected in reverse polarity to a high voltage current source, e.g. a battery, this can destroy the bypass
diodes. This breaks the entire module. Bypass diodes can only be changed and replaced by a specialist approved by
IBC SOLAR AG.
IAED-V241119 Page 8 from 20
The nominal value of the overcurrent blocking device must not exceed the maximum value of the fuse specified on the
back of the module.
The module is fitted with pre-installed bypass diodes ex-works, which are inside the socket.
The junction box is not suitable for modifications during installation and must not be opened under any circumstances.
If the socket is opened, the module guarantee will expire. If you suspect a module has electrical problems, after
consulting with IBC SOLAR AG or the installer, you should send it back to IBC SOLAR AG for inspection and, if
necessary, repairs, in accordance with the IBC SOLAR AG guarantee conditions.
In normal operation, it is likely that in certain conditions the current intensity and/or voltage produced by the PV module
exceeds the values determined under standard test conditions. Therefore, the values specified on the modules for
short-circuit current (Isc) and open circuit voltage (Uoc) should be multiplied by a factor of 1.25 to calculate the
components' nominal voltage, conductor capacities, fuse sizes and the size of the controls connected to the module
output.
The IBC SOLAR AG modules are certified for application class A.
Application class A certified modules can be used in systems that are operated with over 50 V direct current or 240 W in
areas with general public access.
Application class A modules that meet the IEC 61730 standard, will also meet the requirements for safety class II.
The electrical data can be found in the respective data sheet.
3.1.1 Maximum number of modules in series / parallel strings
For a series connection of solar modules the individual voltage of each module is added to a total system voltage. The
maximum number of PV modules that may be connected in a series string had to be calculated in accordance with
applicable regulations in such way that the specified maximum system voltage of the PV module and all other electrical
DC components will not be exceeded in open-ciruit operation at the lowest temperature expected at the PV system is
installed.
The total system voltage must not under any circumstances exceed the maximum permitted input voltage of the
inverter as this will damage it. Due to the negative temperature coefficients of the solar modules, the open circuit
voltage of the whole system must also be calculated at the minimum permitted temperature (see data sheet).
For example, if an inverter with a maximum input voltage of 1000 volts is used, then a maximum of 25 modules can be
connected in series (e.g.: IBC PolySol 280 CS5). If an inverter with a maximum input voltage of 1500 volts is used, then a
maximum of 33 modules can be connected in series (e.g.: IBC MonoSol 370 OS9-HC). Make absolutely sure that the
voltage range of your inverter is different from this. The specifications we have given in this context must be taken as
examples. The total system voltage that results from the series connection of solar modules is calculated from the
individual voltage of a solar module (Voc) at a temperature of −10 °C and an irradiation strength of 1000 W/m² multiplied
by the number of modules. For the case the lowest expected temperature leads to a higher number of modules in one
string, the user has the burden of proof that the specified system voltage of the PV module and all components will
never be exceeded.
For parallel module connection, always ensure that the same number of modules in the parallel strings to be connected
are also connected in series and suitable precautions against over-voltage (e.g. string fuse) are taken.
Please find the maximum number of parallel strings that can be connected without using overcurrent protection in
series on the module-specific data sheet. If properly implemented and certified overcurrent protection is connected in
series with each string, further strings can be operated above this maximum number.
IAED-V241119 Page 9 from 20
Please ensure that the specified capacity with regard to the reverse current is not exceeded
Warning:
The reverse current resistance of the modules depends on the type and can be found on the relevant data sheet. If the maximum
value of the reverse current stated on the data sheet can be exceeded, each module or module row must be installed with a
lawfully registered and certified overcurrent blocking device (fuse or current interruption) in series. The safety value of the
modules can also be found on the data sheet!
3.2 Grounding
Regional or national requirements may include an obligation to ground module frames. Grounding module frames may
also be necessary for preventing lightning strikes/overvoltage.
A grounding connection must be installed as per the regulations and standards accordingly. Please enquire about this
before installation.
Use stainless steel self-tapping screws for grounding. The anodisation of frame parts must be halted by using stainless
steel self-tapping serrated washers.
Use the grounding holes designed for this purpose. (Grounding holes marked on back of module frame)
Do not make any further holes in the frame.
3.3 Mechanical installation
The modules should be installed so that they are directly exposed to as much sunlight as possible with absolutely
minimal shadows. Even partial shade can damage the solar modules, cause the PV generator to malfunction or lead to
loss of power.
The modules must be securely attached. To do this, use special elevated installations or assembly kits for use with
photovoltaic systems.
The modules must be installed with a minimum inclination angle of 5° in relation to horizontal. You should avoid
inclination angles that are too low as dirt can collect on the glass surface and become trapped in the frame. Dirt
accumulation on the module surface can cause shadowing on active solar cells, thereby reducing electrical power. The
maximum inclination angle must not exceed 75° in relation to horizontal. For the case the prefered inclination angel is
off the afore mentioned range, please contact IBC SOLAR AG.
IAED-V241119 Page 10 from 20
All the modules in a photovoltaic generator must be adjusted to the same angle (both horizontally and vertically).
Separate inverters are provided for angular deviations.
During roof assembly, please ensure that you leave sufficient ventilation space underneath the modules (laminate) for
cooling of the reverse (minimum distance 70 mm), in the case of rebated roofs, the deep beading is decisive..
The distance between the individual modules must be at least 10 mm. To account for the thermal linear expansion of the
module frame, IBC SOLAR AG recommends increasing the distance between two modules to 20 mm. The distance
between the individual modules must be at least 10 mm. To account for the thermal linear expansion of the module
frame, IBC SOLAR AG recommends increasing the distance between two modules to 20 mm. The distance between the
individual modules must be at least 10 mm. To account for the thermal linear expansion of the module frame, IBC SOLAR
AG recommends increasing the distance between two modules to 20 mm.
Always ensure that the back of the module does not come into contact with foreign objects or structural elements,
particularly if the module is mechanically loaded.
IBC SOLAR AG permits several different assembly procedures. For detailed information on the permitted assembly
procedures with the permitted clamping areas, please refer to the diagrams on page 14!
When using the assembly holes, please make sure that you use the assembly holes in the clamping areas as standard.
Assembly holes outside the clamping areas are for attaching additional items e.g. when there is high snow loads.
If you want to use assembly procedures that are not described in the diagrams please contact IBC SOLAR AG for
approval. Otherwise your guarantee and module certification will become invalid.
Alongside the instructions in the installation manual, please always follow the installation instructions from the elevated
installation manufacturer. In cases where the instructions from this manufacturer are stricter than the ones in this
installation manual, they take priority.
If the maximum permitted load specified by the mounting frame manufacturer is lower than the one in this installation
manual, the maximum load given by the mounting frame manufacturer is always obligatory.
Make sure that the modules are not loaded above the maximum load limit through wind and/or snow (see chapter 3.4)
and that they are not exposed to excessive forces due to thermal expansion of the support structure. Secure the solar
modules so that they all withstand expected loads and weather-related influences.
The maximum loads apply to uniformly distributed load from wind or snow. Avoid assembling the modules in areas when
there is a risk of sliding snow, icicles or ice formation. Possible snow loads should be calculated separately. If necessary,
measures should be taken to prevent damage.
IAED-V241119 Page 11 from 20
For detail load permissions please refer to chapter 3.4
.
The solar modules can be attached using clamps or alternatively directly on the assembly holes (position of assembly
holes as shown on data sheet). It is recommended to use only IBC module clamps of the various current available series
to fasten the modules. These module clamps have been tested and approved in interaction with the modules. When
using module clamps, general care must be taken to avoid any damage to the module and to establish a sufficient
connection between the clamp and the module. The correct installation for a sufficient connection of the module
clamps is explained in the installation instructions of the IBC mounting products. Please do not damage the modules
whilst doing this and ensure a proper connection between clamp and module.
Only use corrosion-free screws, nuts and washers during assembly.
Sufficient lightning protection is recommended, particularly on exposed sites. Integration into any existing lightning
protection must follow the relevant guidelines.
Only mount solar modules upright with the socket facing upwards or transversely.
On the elevation, please ensure that rainwater or condensation cannot run in the direction of the cable screw joints on
the sockets.
The solar module must not stand in backwater or condensation.
The modules must be attached flush to the substructure, without tension, deformation and torsion, within the decribed
clamping ranges.
The clamping must be done symmetrically and at 4 points.
The clamps must not touch the front glass of the module. Deformation or damage of the module must be avoided.
Make sure that the clamps do not shadow the module.
IAED-V241119 Page 12 from 20
3.4 Assembly variants
3.4.1 Clamping short and long frame side
Clamping long side
Clamping short side
IAED-V241119 Page 13 from 20
A
B
Module type
Test Load
Push/Pull [Pa]
Design Load *
Push/Pull [Pa]
Test Load
Push/Pull [Pa]
Design Load *
Push/Pull [Pa]
IBC Module Transparent xxx ES-TA1
1762 x 1134 x 30 mm
0-270 mm
1600 / 1600
270-340 mm
5400 / 2400
340-440 mm
4800 / 2400
0-100 mm
1800/1800
0-270 mm
1067 / 1067
270-340 mm
3600 / 1600
340-440 mm
3200 / 1600
0-100 mm
1200/1200
0-220 mm
2400 / 1200
300-400 mm
4800 / 1200
0-220 mm
1600 / 800
220-280 mm
3200 / 800
IBC MonoSol xxx GS10-HC-N
1722 x 1134 x 30 mm
100-200 mm
2400/2400
200-316 mm
3600/2400
100-200 mm
1600/1600
200-316 mm
2400/1600
0-250 mm
2400 / 2400
0-250 mm
1600 / 1600
316-416 mm
5400/2400
190-300 mm
3600 / 2400
316-416 mm
3600/1600
190-300 mm
2400 / 1600
50-150 mm
3600 / 1600
50-150 mm
2400 / 1067
IBC Module Bifacial xxx LS-TA1
1722 x 1134 x 30 mm
300-400 mm
5400 / 2400
300-400 mm
3600 / 1600
150-260 mm
5400 / 1600
150-260 mm
3600 / 1067
400-540 mm
3600 / 2400
190-300 mm
3600 / 2400
400-540 mm
2400 / 1600
190-300 mm
2400 / 1600
260-360 mm
3600 / 1600
50-150 mm
3600 / 1600
260-360 mm
2400 / 1067
50-150 mm
2400 / 1067
IBC Module Transparent xxx LS-TA2
1762 x 1134 x 30 mm
300-400 mm
5400 / 2400
300-400 mm
3600 / 1600
150-260 mm
5400 / 1600
150-260 mm
3600 / 1067
IBC Module White xxx MS-TA1
IBC Module Black xxx MS-TA1
1762 x 1134 x 30 mm
400-540 mm
3600 / 2400
260-300 mm
2400 / 2400
300-450 mm
5400 / 2400
450-500 mm
2400 / 2400
400-540 mm
2400 / 1600
260-300 mm
1600 / 1600
300-450 mm
3600 / 1600
450-500 mm
1600 / 1600
260-360 mm
3600 / 1600
100-240 mm
2400 / 2400
Note:
Position of module clamps = distance between outer edge of the module and the middle of the used clamp.
*Loads according to IEC 61215-2:2016 ; Design load = Test load / safety factor 1.5
260-360 mm
2400 / 1067
100-240 mm
1600 / 1600
IAED-V241119 Page 14 from 20
3.4.2 Insertion systems for long and short side
Insertion system for long side
Insertion system for short side
Module type
Insertion system for long side
Test Load
Push/Pull [Pa]
Design Load *
Push/Pull [Pa]
Insertion system for short side
Test Load
Push/Pull [Pa]
Design Load *
Push/Pull [Pa]
IBC Module Transparent xxx ES-TA1
1762 x 1134 x 30 mm
IBC MonoSol xxx GS10-HC-N
1722 x 1134 x 30 mm
IBC Module Bifacial xxx LS-TA1
1722 x 1134 x 30 mm
IBC Module Transparent xxx LS-TA2
1762 x 1134 x 30 mm
2400 / 2400 1600 / 1600 1600 / 1600 1067 / 1067
3600 / 2400 2400 / 1600 2400 / 2400 1600 / 1600
3600 / 2400 2400 / 1600 1800 / 1800 1200 / 1200
3600 / 2400 2400 / 1600 2400 / 2400 1600 / 1600
IBC Module White xxx MS-TA1
IBC Module Black xxx MS-TA1 2400 / 2400 1600 / 1600 1200 / 1200 800 / 800
1762 x 1134 x 30 mm
Note:
*Loads according to IEC 61215-2:2016 ; Design load = Test load / safety factor 1,5
IAED-V241119 Page 15 from 20
3.4.3 IBC AeroFix G3 mounting system
AeroFix G3*
Module type
Test Load
Push/Pull [Pa]
Design Load **
Push/Pull [Pa]
IBC Module Transparent xxx ES-TA1
1762 x 1134 x 30 mm
IBC MonoSol xxx GS10-HC-N
1722 x 1134 x 30 mm
IBC Module Bifacial xxx LS-TA1
1722 x 1134 x 30 mm
IBC Module Transparent xxx LS-TA2
1762 x 1134 x 30 mm
1400 / 1400 930 / 930
1400 / 1400 930 / 930
1800 / 1800 1200 / 1200
1600 / 1600 1067 / 1067
IBC Module White xxx MS-TA1
IBC Module Black xxx MS-TA1
1600 / 1600 1067 / 1067
1762 x 1134 x 30 mm
Note:
*AeroFix system with clamping on the short side, C= starting directly at the outer edge of the module on the short frame side in
the length of the clamp. Please refer for more information to the valid IBC AeroFix installation manual.
**Loads according to IEC 61215-2:2016 ; Design load = Test load / safety factor 1,5
IAED-V241119 Page 16 from 20
4. Maintenance
Regular maintenance of the modules is not necessary. However, it is recommended that you examine the modules
regularly for any damage to the glass surface, rear side foil, frame, junction box or external electrical connections. The
electrical connections should be examined for loose connections and rust formation.
PV modules operate efficiently even if they have never been washed. Nevertheless, the output power can be increased
by removing dirt on the glass surface. Dust, dirt or other residue on the coated glass surface can be regularly washed
away with water. Stubborn dirt on the coated glass can be removed with a microfibre cloth and a ph-neutral cleaning
agent or with a commercial glass cleaner.
On no account should the glass surface be treated with aggressive cleaning agents, abrasive cleaners or chemicals.
Only use ph-neutral cleaning agents.
Always wear rubber gloves whilst servicing, washing or cleaning the modules to insulate and protect yourself from
electric shock.
5. Cleaning the modules
The glass surface of the modules normally cleans itself in rainwater. However, with for example a rather low roof inclination, it may
be necessary to clean the modules. In this case, please follow the instructions below.
Do not clean the modules if there is a risk of frost or marked differences between the temperature of the module, air and water.
Ideally, clean the solar modules in the early morning or late evening, at low irradiation levels and medium temperatures. Avoid
cleaning the modules on hot sunny days, in the middle of the day or when there is high irradiation levels and high temperatures.
The module temperature should be between 10° and 30 °C.
Use the following cleaning items:
Soft cloth
Cleaning rags or cloths
Squeegee
Commercial glass cleaner (with low alcohol concentration)
Unconcentrated, PH-neutral cleaner
Water and mild soap
Avoid the following cleaning items:
Wire brushes, steel wool or sharp-edged tools that could scratch the glass
High-pressure washers
Cleaning agents with ammonia or other alkaline products
Abrasive cleaning agents
Solvents such as petrol, acetone, highly concentrated alcohol or organic compounds
Any sort of polishing paste such as polish for metals or cars
IAED-V241119 Page 17 from 20
6. Transport and storage
Do not set a module down heavily on a surface. Take particular care when the module is on an edge.
During transport and storage, ensure that each solar module is sufficiently supported.
Use a glass suction cup to remove and transport a module or hold the module solely by the module frame. Transport the
module vertically over longer distances.
The modules should not be held or transported by a single section of the frame.
Under no circumstances should you lift or move the module using the connection cables or socket.
Do not let the module drop.
Do not place any objects on the modules.
Do not handle the modules using pointed objects.
When setting down or transporting individual modules directly to the assembly site (e.g. roof), avoid damaging them in
any way.
7. Disposal
Faulty or old solar modules must be disposed of correctly. They should not be disposed of with household waste but according to
the valid disposal regulations for electronic scrap.
IAED-V241119 Page 18 from 20
8. Disclaimer
IBC SOLAR AG does not control the use of this safety, installation and instruction manual or the conditions and procedures for
installing, operating, using and maintaining the modules. Therefore, IBC SOLAR AG does not accept any responsibility for loss,
damage, injury or costs that may occur during installation, operation, use and maintenance of the modules or in relation to this
and expressly rejects any liability for cases of this sort. IBC SOLAR AG does not accept any responsibility for patent infringements
or other infringements from third parties that may be caused through the use of the modules. "Use" does not include implicit or
other licensing under any patent or Patent Act. The information in this manual is based on the knowledge and experience of IBC
SOLAR AG and is considered to be reliable. However, information, product specifications (without restriction) and suggestions
have neither the explicit or implicit nature of a guarantee. IBC SOLAR AG reserves the right to make changes to products,
specifications or this manual without prior notice.
IAED-V241119 Page 19 from 20
Installationsanleitung
Photovoltaikmodule der Typen
IBC Module Transparent xxx ES-TA1
IBC MonoSol xxx GS10-HC-N
IBC Module Bifacial xxx LS-TA1
IBC Module Transparent xxx LS-TA2
IBC Module White xxx MS-TA1
IBC Module Black xxx MS-TA1
Stand: 19.11.2024
Sicherheits-, Installations- und Betriebshandbuch
Entspricht den Sicherheitsanforderungen nach IEC 61730;
Nicht UL zugelassen.
Elektrische Anlage – Bitte wenden Sie sich an Ihren Installateur
Photovoltaikmodule (PV-/Solarmodule) erzeugen unter Lichteinstrahlung
Gleichstrom. Die vorliegende Installationsanleitung enthält wichtige
Informationen zur Sicherheit, Installation und zum Betrieb der Module, die Sie
kennen sollten, bevor Sie die Module verwenden.
Inhaltsverzeichnis
1. Allgemeine Informationen........................................................................................................ 3
2. Sicherheitshinweise ................................................................................................................... 5
2.1 Allgemeine wichtige Hinweise und Normen ................................................................................................................................................ 5
2.2 Sicherheitshinweise bei der Modulhandhabung ..................................................................................................................................... 5
2.3 Sicherheitsvorkehrungen bei der Installation ............................................................................................................................................ 6
3. Installation ...................................................................................................................................... 8
3.1 Elektrische Installation .............................................................................................................................................................................................. 8
3.1.1 Maximale Anzahl Module in Reihe / Stränge Parallel ........................................................................................................................................................ 9
3.2 Erdung .............................................................................................................................................................................................................................. 10
3.3 Mechanische Installation ....................................................................................................................................................................................... 11
3.4 Montage Varianten ................................................................................................................................................................................................... 13
3.4.1 Klemmung an der kurzen und langen Seite ......................................................................................................................................................................... 13
3.4.2 Einlegesystem lange und kurze Seite ..................................................................................................................................................................................... 15
3.4.3 IBC AeroFix G3 (Flachdachsystem)......................................................................................................................................................................................... 16
4. Wartung und Pflege .................................................................................................................. 17
5. Reinigung der Module ............................................................................................................. 18
6. Transport und Lagerung ......................................................................................................... 19
7. Entsorgung.................................................................................................................................... 19
8. Haftungsvorbehalt.................................................................................................................... 20
IAED-V241119 Seite 2 von 21
1. Allgemeine Informationen
Mit dem Kauf von Solarmodulen der IBC SOLAR AG haben Sie ein sehr hochwertiges Produkt erstanden. Damit Sie
uneingeschränkt und dauerhaft Freude an Ihren neuen Solarmodulen haben, lesen Sie diese Installationsanleitung bitte
sorgfältig und beachten Sie unbedingt die genannten Hinweise noch bevor Sie beginnen die Module zu installieren, zu verkabeln,
in Betrieb zu nehmen, zu warten oder zu transportieren.
Bevor Sie versuchen, die Module zu installieren, zu verkabeln, in Betrieb zu nehmen und zu warten, vergewissern Sie
sich zunächst, dass Sie alle Sicherheitsinformationen in dieser Installationsanleitung gelesen und verstanden haben.
Die Solarmodule müssen nach den anerkannten Regeln der Technik montiert und betrieben werden. Bei der Montage
sind die jeweiligen nationalen Vorschriften zum Arbeitsschutz und zur Unfallverhütung unbedingt zu beachten und
einzuhalten. Dies gilt insbesondere für Arbeiten auf dem Dach.
Beachten Sie bei der Installation alle örtlichen, regionalen, nationalen und internationalen gesetzlichen Bestimmungen,
Richtlinien, Normen und Verordnungen, sowie die Vorschriften der Berufsgenossenschaften zur Arbeitssicherheit.
Montage, Installation und Inbetriebnahme dürfen nur von lizenzierten und qualifizierten Fachleuten durchgeführt
werden.
Bei Arbeiten an Solargeneratoren, vor allem auf Dächern, sind geeignete Sicherheitsvorkehrungen (z. B.
Absturzsicherungen) zu verwenden.
Das Solarmodul ist vor der Installation auf seine mechanische Unversehrtheit zu prüfen. Beschädigte Solarmodule (z. B.
Module mit gebrochenem Glas, Beschädigungen an der Rückseitenisolierfolie) dürfen nicht installiert werden. Eine
Beschädigung der Rückseitenisolierfolie kann schwere Folgen haben (z. B. Delamination, Gefahr für Leben und
Gesundheit).
Die Module erzeugen auch dann Spannung, wenn sie nicht an einen Stromkreis oder Belastungswiderstand
angeschlossen sind. Bereits bei einer Lichteinstrahlung von nur 5 % des vollen Sonnenlichts erzeugen die Module
beinahe die volle Spannung. Stromstärke und -leistung nehmen mit der Lichtintensität zu.
Die von den Modulen erzeugte Ausgangsleistung kann über der spezifizierten Nennleistung liegen.
Die Nennwerte nach Industriestandard werden bei 1000 W/m² Strahlungsintensität und 25 °C Solarzellentemperatur
ermittelt. Kältere Temperaturen können eine starke Erhöhung von Spannung und Leistung bewirken.
Stellen Sie sicher, dass die Module nur Umgebungstemperaturen im Bereich von −40° bis +85 °C ausgesetzt werden.
Die vom Modul erzeugte Stromstärke, Spannung und daraus resultierende Leistung kann sich infolge von Reflexion
durch Schnee, Wasser oder andere reflektierende Oberflächen erhöhen.
Vermeiden Sie es, Lichtstrahlen zu bündeln und auf das Modul zu lenken. Selbst bei geringster Beleuchtungsstärke ist
mit der vollen Leerlaufspannung der Module zu rechnen, d. h. bei der Installation ist stets Vorsicht in Bezug auf
elektrische Fehler z. B. Kurzschlüsse geboten.
Die Module sind ausschließlich für den Betrieb unter freiem Himmel und auf festem Boden gedacht. Sie sind nicht für
den Betrieb/Einsatz in Innenräumen oder an Fortbewegungsmitteln jeglicher Art ausgelegt.
Nicht vorgesehen ist darüber hinaus der Betrieb oder Einsatz in gefährdeten Bereichen. Dies sind insbesondere
Installationen, bei denen die Module in Kontakt mit Salzwasser kommen bzw. teilweise oder vollständig in Süß- oder
Salzwasser getaucht werden könnten – z. B. auf Booten oder an Bojen. Der Abstand zur Küste muss mindestens 500 m
betragen. (Bei geringeren Abständen, wenden Sie sich bitte an IBC SOLAR AG)
IAED-V241119 Seite 3 von 21
Verwenden Sie ausschließlich Geräte, Stecker, Kabel und Aufständerungen, die für den Einsatz in einem
Photovoltaiksystem geeignet sind.
Beachten Sie alle Sicherheitsmaßnahmen und -hinweise für die weiteren eingesetzten Komponenten.
Bei einer auch kurzfristigen Lagerung nicht miteinander verbundener Module im Freien müssen Module, die mit der
Glasseite nach unten liegen, abgedeckt werden. Dies dient der Verhinderung von Wasseransammlungen am Modul und
schützt die freiliegenden Stecker vor Beschädigungen.
IAED-V241119 Seite 4 von 21
2. Sicherheitshinweise
Um Schäden sowohl an Personen, als auch an den Solarmodulen unter allen Umständen auszuschließen, beachten Sie
unbedingt die nachfolgenden Sicherheitshinweise.
2.1 Allgemeine wichtige Hinweise und Normen
Die gesamte PV-Anlage muss nach den allgemein anerkannten Regeln der Technik montiert werden. Bitte beachten Sie
unbedingt die Unfallverhütungsvorschriften, die in dem Land, in welchem die Solarmodule zum Einsatz kommen, Gültigkeit
haben.
Bitte beachten Sie sämtliche öffentlich-rechtliche Regelungen und Vorgaben, nationale Normen, technische
Anschlussbedingungen, Unfallverhütungsvorschriften, die jeweils gültigen Richtlinien der Sachversicherer, die Fachregeln des
Dachdeckerhandwerks und alle weiteren, relevanten Allgemeine Richtlinien bei der Planung, Errichtung, dem Betrieb und der
Instandhaltung von netzgekoppelten PV Anlagen.
Unzulässige Änderungen sowie bestimmungswidrige Verwendung unserer Komponenten bei der Montage und an der
Konstruktion können zum Ausschluss jeglicher Haftungsansprüche führen.
Die Solarmodule sind nach IEC 61215 und IEC 61730 (Schutzklasse II) zertifiziert!
2.2 Sicherheitshinweise bei der Modulhandhabung
Behandeln Sie ihre Solarmodule stets behutsam, um Beschädigungen zu vermeiden. Treten Sie insbesondere nicht auf
das Modul. Lassen Sie es nicht fallen und schützen Sie es vor herabfallenden Gegenständen.
Solarmodule dürfen nicht an den Anschlusskabeln oder der Anschlussdose gehalten oder transportiert werden.
Benutzen Sie einen Glassauger zur Entnahme und zum Transport eines Moduls oder halten Sie das Modul
ausschließlich am Modulrahmen. Transportieren Sie das Modul über längere Strecken nur senkrecht.
Achten Sie darauf, dass die Rückseite der Module nicht beschädigt oder zerkratzt wird und setzen Sie das Modul nicht
hart auf einer Oberfläche ab. Seien Sie besonders behutsam, wenn das Modul auf einer Kante abgestellt wird.
Unterlassen Sie es, das Modul zu demontieren, zu ändern oder anzupassen oder irgendein von IBC SOLAR AG
angebrachtes Teil oder Etikett ohne Einverständnis von IBC SOLAR zu entfernen, da andernfalls die Garantieansprüche
erlöschen.
Die Modulrahmen dürfen nicht angebohrt, angenagelt oder angeschweißt werden. Bohren Sie keine Löcher in die
Glasfläche des Moduls. Andernfalls erlöschen die Garantieansprüche. Tragen Sie keine Farbe und keinen Klebstoff auf
das Modul auf.
Lassen Sie das Modul nie ungesichert und ohne Halterung stehen.
Module mit zerbrochener Glasoberfläche oder einem Riss in der Rückseitenfolie sind irreparabel beschädigt und dürfen
keinesfalls verwendet werden, da jede Berührung mit der Moduloberfläche oder der Aufständerung einen elektrischen
Schlag verursachen kann.
Zerbrochene oder beschädigte Module müssen vorsichtig behandelt und ordnungsgemäß entsorgt werden.
Zerbrochenes Glas kann scharfe Kanten aufweisen und Verletzungen verursachen, wenn es nicht mit geeigneter
Schutzausrüstung gehandhabt wird.
IAED-V241119 Seite 5 von 21
Arbeiten Sie nur in trockener Umgebung, und verwenden Sie trockene Werkzeuge. Arbeiten Sie nur mit den Modulen,
wenn diese vollständig trocken sind; es sei denn, Sie verfügen über geeignete Schutzausrüstung.
Stapeln Sie die Module nicht aufeinander, um Beschädigungen zu vermeiden.
Schützen Sie die Steckkontakte soweit möglich vor Verschmutzungen bzw. treffen Sie geeignete
Reinigungsmaßnahmen der Kontakte, wenn es zu Verschmutzungen gekommen ist.
Tragen Sie bei der Installation der Module immer Handschuhe, um ihre eigene Sicherheit zu gewährleisten und um die
Module vor Verunreinigungen zu schützen (insbesondere bei Modulen mit ARC-Glas).
2.3 Sicherheitsvorkehrungen bei der Installation
Achten Sie darauf, dass sich während der Installation keine Kinder und nicht autorisierte Personen in der Nähe des
Systems oder der Module befinden. Führen Sie Installationsarbeiten nicht bei starkem Wind aus.
Vor der Installation sind Anschlussdose, Kabel und Steckverbinder auf Schäden und Verschmutzungen zu prüfen.
Installieren Sie keine beschädigten PV-Module oder PV-Module mit verschmutzten Steckverbindern.
Wenn die Module nicht ebenerdig installiert werden, treffen Sie geeignete Sicherheitsvorkehrungen und verwenden Sie
geeignete Schutzvorrichtungen, um Schäden durch das Herunterfallen von Modulen und andere Sicherheitsrisiken zu
vermeiden.
Photovoltaikmodule haben keinen Ein-/Ausschalter. Sie lassen sich nur außer Betrieb setzen, indem sie der
Lichteinstrahlung entzogen werden. Hierzu muss entweder ihre vordere Oberfläche mit einem Tuch, Karton oder einem
anderen vollständig lichtundurchlässigen Material abgedeckt werden oder sie müssen mit der vorderen Oberfläche
nach unten auf eine glatte, flache Fläche gelegt werden.
Das Trennen von Gleichstrom führenden Leitern kann zu Lichtbögen führen. Daher ist es erforderlich vor Beginn
jeglicher Arbeiten an der Solaranlage, insbesondere vor dem Trennen der Steckverbinder im Gleichstromkreis, den
Wechselrichter vom Wechselspannungsnetz zu trennen.
Wenn Sie unter Lichteinwirkung mit Modulen arbeiten, befolgen Sie alle Bestimmungen und Verordnungen für die
Arbeit mit elektrischen Anlagen unter Stromeinwirkung. Beachten Sie bitte auch, dass durch die Serienschaltung von
Modulen der Kleinspannungsbereich (< 120 V DC) deutlich überschreiten kann. Seien Sie deshalb besonders vorsichtig.
Vermeiden Sie bei der Installation und während das Modul unter Lichteinwirkung steht, die Berührung der elektrischer
Anschlussklemmen oder Kabelenden.
Die Solarmodule, insbesondere die Steckverbinder und Werkzeuge, müssen während der Installation trocken sein.
Tragen Sie beim Verrichten mechanischer oder elektrischer Installationsarbeiten keinen Schmuck und keine
Accessoires aus Metall. Führen Sie des Weiteren keine elektrisch leitenden Teile in die Buchsen oder Anschlussdosen
ein.
Unterbrechen Sie niemals elektrische Verbindungen und ziehen Sie keine Stecker heraus, während der Schaltkreis
unter Strom steht.
Die Berührung elektrisch geladener Modulteile wie z. B. Anschlussklemmen kann zu Verbrennungen, Funkenbildung
und elektrischen Schlägen mit Todesfolge führen. Dies gilt selbst dann, wenn das Modul nicht angeschlossen ist.
Verwenden Sie nur isolierte Werkzeuge und tragen Sie Gummihandschuhe, die für elektrische Installationsarbeiten
zugelassen sind.
IAED-V241119 Seite 6 von 21
Vermeiden Sie es die Modulkabel mechanisch zu belasten, Entwässerungsöffnungen zu verdecken oder zu
ermöglichen, dass Wasser in Richtung der Steckverbindungen laufen kann.
Falls erforderlich, treffen Sie bitte geeignete Blitzschutzmaßnahmen gemäß der länderspezifischen Normen und
Vorschriften. Verfügt das Gebäude über eine Blitzschutzanlage, so müssen Modulrahmen und Montagesystem in den
äußeren Blitzschutz eingebunden und ggf. zusätzlich Überspannungs-Schutzgeräte installiert werden. Wenden Sie sich
dafür an eine Blitzschutzfachkraft.
Bitte informieren Sie sich bei den örtlichen Behörden über die Brandschutzrichtlinien und –anforderungen für Häuser
und Gebäude.
Konstruktion und Anbringung auf dem Dach können sich auf die Brandsicherheit eines Gebäudes auswirken. Fehler in
diesen Bereichen können im Brandfall Gefahren verursachen.
Bei Anbringung auf dem Dach sollten die Module auf einer feuerfesten, für diesen Zweck zugelassenen Beschichtung
(evtl. Oberfläche) montiert werden.
Unter Umständen werden Komponenten wie Fehler- und Stromschutzschalter, Sicherungen und Ladeschalter benötigt.
Setzen Sie die Module nicht in der Nähe von Geräten oder Orten ein, wo Gas erzeugt wird oder sich Gas ansammeln
kann. Solarmodule dürfen nicht in der Nähe leicht entzündlicher Stoffe oder Dämpfe installiert werden. Solarmodule
sind keine explosionsgeschützten Betriebsmittel.
Solarmodule der IBC SOLAR AG gelten als Bauprodukte im Sinne der Festlegung des DIBt (Deutsches Institut für
Bautechnik). Die Anforderungen aus der aktuellen Bauregelliste (BRL) sind zu berücksichtigen.
IAED-V241119 Seite 7 von 21
3. Installation
3.1 Elektrische Installation
Treffen Sie beim Installieren, Verkabeln, Betreiben und Warten des Moduls alle erforderlichen Vorkehrungen, um
elektrische Gefahren zu vermeiden.
Vergewissern Sie sich, dass alle elektrischen Verbindungen sicher geschlossen sind.
Wenn die Gleichspannung im System insgesamt 100 V übersteigt, müssen Installation, Übergabe und Wartung von
einem lizenzierten Elektriker durchgeführt werden, sofern die örtlichen Verordnungen für den Umgang mit elektrischen
Systemen nichts anderes vorsehen.
Die Berührung mit einer Gleichspannung von 30 V oder mehr ist potenziell gefährlich.
Setzen Sie Module mit unterschiedlicher elektrischer oder physischer Ausstattung nicht innerhalb desselben Systems
ein. Es dürfen nur identische Solarmodule gleichen Typs und gleicher Leistungsklasse verschaltet werden.
Die maximale Leerlaufspannung des Systems darf die maximale Systemspannung des Moduls nicht überschreiten.
Alle IBC SOLAR AG-Module sind ab Werk mit Anschlusskabeln und Steckern versehen. Sie lassen sich aufgrund ihrer
Konstruktionsweise bequem in Reihe installieren.
Bei der Montage ist auf eine Zugentlastung der Modulanschlusskabel zu achten.
IBC SOLAR AG Module sind mit Multi-Contact® Typ 4 Klickstecker für Systemspannungen bis 1000 V und mit Multi-
Contact® Typ EVO2 und EVO2A für Systemspannungen bis 1500 V ausgerüstet.
Die Steckerverbindungen mit Multi-Contact® Typ 4 können zusätzlich mit dem von Multi-Contact® erhältlichen
steckbaren Sicherheits- Sperrclip PV-SSH4 geschützt werden. Die werksseitig angebrachten Solarstecker und
Anschlusskabel dürfen nicht entfernt werden. Für die PV Module mit Multi-Contact® Typ EVO2 und EVO2A liegt aktuell
kein Sperrclip vor.
Der Clip PV-SSH4 wird nicht von IBC SOLAR AG bereitgestellt und muss separat erworben werden. Wenn der Sperrclip
installiert ist, kann die Steckerverbindung des PV-Moduls nur mit dem ebenfalls bei Multi-Contact® erhältlichen PV-MS
Werkzeug entsperrt werden.
Unter Beachtung der Systemspannung bis 1000 V garantiert Stäubli als Hersteller eine Interkonnektivität und
Steckbarkeit innerhalb der Multi-Contact® Steckerfamilie. Dies gilt auch für die Interkonnektivität und Steckbarkeit bei
dem Multi-Contact® Typ EVO2 und dem Multi-Contact® Typ EVO2A.
Die Biegeradien der Anschlussleitungen müssen mindestens das fünffache des äußeren Leitungsdurchmessers
betragen.
Achten Sie bei der Systemverkabelung auf geeignete Querschnitte und Anschlüsse, die für die maximale
Kurzschlussstromstärke des Moduls zugelassen sind. Die Kabel müssen einen Mindestquerschnitt von 4mm² besitzen
und die Isolation muss für die maximale Systemleerlaufspannung zugelassen sein.
Für die Verschaltung der Modulstrings sind nur geeignete Kabel für die Außenmontage zu verwenden.
Die Kabel sind gegen Beschädigungen zu schützen.
Anschlussdose, Kabel und Anschlussstecker dürfen nicht mit öl-, fett- oder alkoholhaltigen Substanzen gereinigt oder
benetzt werden.
IAED-V241119 Seite 8 von 21
Achten Sie beim Herstellen der Verbindungen auf die passenden Polaritäten der Kabel und Anschlussklemmen.
Andernfalls besteht die Gefahr, dass das Modul beschädigt wird.
Wenn Module in umgekehrter Polarität an eine Starkstromquelle wie z. B. eine Batterie angeschlossen werden, führt dies
zur Zerstörung der Bypass-Dioden. Damit ist das gesamte Modul defekt. Bypass-Dioden dürfen nur von einer Fachkraft
nach Freigabe von der IBC SOLAR AG getauscht und ersetzt werden.
Der Nennwert der Überstromsperre darf den auf der Modulrückseite angegebenen Maximalwert der Sicherung nicht
überschreiten.
Das Modul ist ab Werk mit bereits installierten Bypass-Dioden ausgestattet, die sich im Innern der Anschlussdose
befinden.
Die Anschlussdose ist nicht für Veränderungen bei der Installation geeignet und darf unter keinen Umständen geöffnet
werden. Wenn die Anschlussdose geöffnet wird, erlischt die Garantie des Moduls. Module, bei denen Verdacht auf ein
Elektrizitätsproblem besteht, sollten gemäß den Garantiebedingungen von IBC SOLAR AG, nach Rücksprache mit IBC
SOLAR AG oder dem Installateur, zur Untersuchung und ggf. Reparatur an IBC SOLAR AG zurückgeschickt werden.
Im Normalbetrieb ist es unter bestimmten Bedingungen wahrscheinlich, dass die vom Photovoltaikmodul erzeugte
Stromstärke und/oder Spannung die unter den Standard – Testbedingungen ermittelten Werte überschreitet. Daher
sollten die auf den Modulen angegebenen Werte Für Kurzschlussstrom (Isc) und Leerlaufspannung (Uoc) mit dem
Faktor 1,25 multipliziert werden, um die Komponenten-Nennspannung, die Leiterkapazitäten, die Sicherungsgrößen
sowie die Größe der an den Modulausgang angeschlossenen Regler zu ermitteln.
Die IBC SOLAR AG Module sind für die Anwendungsklasse A zertifiziert.
Für die Anwendungsklasse A zertifizierte Module können in Systemen eingesetzt werden, die mit mehr als 50 V
Gleichstrom oder 240 W in allgemein zugänglichen Umgebungen betrieben werden.
Module der Anwendungsklasse A, die der Norm IEC 61730 entsprechen, genügen auch den Anforderungen der
Sicherheitsklasse II.
Die elektrischen Kennwerte sind dem jeweils gültigen Datenblatt zu entnehmen.
3.1.1 Maximale Anzahl Module in Reihe / Stränge Parallel
Bei einer Reihenschaltung von Solarmodulen addiert sich die Einzelspannung der Module zu einer Gesamt-
Systemspannung. Die maximale Anzahl von Solarmodulen, welche in einem Strang verschalten werden dürfen, muss in
Übereinstimmung mit geltenden Vorschriften erfolgen, so dass die maximale Systemspannung der Solarmodule und
allen anderen DC Komponenten im Leerlaufbetrieb, bei der niedrigsten, zu erwartenden Temperatur am Installationsort,
nicht überschritten wird.
Die Gesamt-Systemspannung darf keinesfalls die zulässige maximale Eingangsspannung des Wechselrichters
übersteigen, da dieser sonst Schaden nimmt. Dazu muss aufgrund des negativen Temperaturkoeffizienten der
Solarmodule auch die Leerlaufspannung des Gesamtsystems bei der minimal zulässigen Temperatur errechnet werden
(siehe Datenblatt)
Wird beispielsweise ein Wechselrichter mit einer maximalen Eingangsspannung von 1000 Volt eingesetzt, dann können
maximal 25 Module (z.B.: IBC PolySol 280 CS5) in Reihe geschaltet werden. Bei einer maximalen Eingangsspannung von
1500 Volt kann die Anzahl auf maximal 33 Module (z.B.: IBC MonoSol 370 OS9-HC) erhöht werden. Beachten Sie
unbedingt, dass der Spannungsbereich ihres Wechselrichters davon verschieden sein kann. Die in diesem
Zusammenhang gemachten Angaben unsererseits sind als Beispiel zu verstehen. Die Gesamt-Systemspannung, die
sich durch die Reihenschaltung von Solarmodulen ergibt, errechnet sich aus der Einzelspannung eines Solarmoduls
IAED-V241119 Seite 9 von 21
(Voc) bei einer Temperatur von −10 °C und einer Bestrahlungsstärke von 1000 W/m² multipliziert mit der Anzahl der
Module. Für den Fall, dass die niedrigste, zu erwartende Temperatur eine höhere Anzahl von Solarmodulen im Strang
ermöglicht, muss der Bertreiber nachweisen, dass die maximale Systemspannung der Solarmodule und aller
Komponenten nicht überschritten wird.
Für die parallele Verschaltung der Module muss sichergestellt sein, dass stets die gleiche Anzahl von Modulen in den
parallel zu schaltenden Strängen in Reihe geschaltet werden und geeignete Maßnahmen zum Überstromschutz (z. B.
Strangsicherung) getroffen werden.
Die Anzahl der maximal parallel verschaltbaren Stränge, ohne Verwendung einer in Reihe geschalteten
Überstromsicherung, entnehmen Sie bitte dem modulspezifischen Datenblatt. Wenn eine korrekt ausgelegte und
zertifizierte Überstromsicherung in Reihe mit jedem Strang geschaltet ist, können über diese maximale Anzahl hinaus
mehrere Stränge parallel betrieben werden.
Es ist darauf zu achten, dass die angegebene Belastbarkeit bezüglich des Rückstroms nicht überschritten wird.
Achtung:
Die Rückstromfestigkeit der Module ist abhängig vom Typ und ist aus dem jeweiligen Datenblatt zu entnehmen! Wenn der
Rückstrom den auf dem Datenblatt angegebenen Maximalwert überschreiten kann, muss mit jedem Modul bzw. jeder Modulreihe
eine ordnungsgemäß zugelassene und zertifizierte Überstromsperre (Sicherung oder Stromunterbrechung) in Reihe installiert
werden. Der Sicherungswert der Module ist ebenfalls dem jeweiligen Datenblatt zu entnehmen!
3.2 Erdung
Regionale oder nationale Bestimmungen können die Pflicht zur Erdung der Modulrahmen beinhalten. Zudem kann die
Erdung der Modulrahmen auch aus Gründen der Vorbeugung gegen Blitzeinschläge/Überspannung notwendig sein.
Eine Erdungsverbindung ist entsprechend nach den Vorschriften und Normen durchzuführen. Bitte erkundigen Sie sich
hierzu vor der Installation.
Verwenden Sie für die Erdung Blechschrauben aus Edelstahl. Die Anodisierung der Rahmenteile muss durch
Verwendung von selbstschneidenden Zahnscheiben aus Edelstahl leitfähig unterbrochen werden.
Verwenden Sie für die Erdung die vorgesehenen Erdungsbohrungen. (Markierung der Erdungsbohrungen auf der
Rückseite des Modulrahmens)
Zusätzliche Bohrungen in den Rahmen dürfen nicht vorgenommen werden.
IAED-V241119 Seite 10 von 21
3.3 Mechanische Installation
Die Module sollten so montiert werden, dass sie dem Sonnenlicht möglichst direkt ausgesetzt sind und möglichst kein
Schatten auf sie fallen kann. Schon eine teilweise Abschattung kann zu Schädigungen der Solarmodule, Ausfällen des
PV-Generators und zu Leistungsverlusten führen.
Die Module müssen sicher befestigt werden. Verwenden Sie hierzu spezielle Aufständerungen oder Montagesätze für
Photovoltaik-Anwendungen.
Die Module müssen mit einem Mindestneigungswinkel von 5° zur Horizontalen montiert werden. Vermeiden Sie
unbedingt zu geringe Neigungswinkel, da sich ansonsten Schmutz auf der Glasoberfläche ansammeln kann und vom
Rahmen gehalten wird. Schmutzansammlungen auf der Moduloberfläche können bei aktiven Solarzellen Abschattungen
verursachen, die die elektrische Leistung verringern. Der maximale Neigungswinkel darf 75° zur Horizontalen nicht
überschreiten. Sollte der bevorzugte Neigungswinkel außerhalb der obengenannten Bereiche liegen, wenden Sie bitte
an IBC SOLAR AG. Alle Module eines Photovoltaikgenerators sind im gleichen Winkel (sowohl horizontal wie auch
vertikal) auszurichten. Bei Winkelabweichungen sind separate Wechselrichter oder Moduloptimierer vorzusehen.
Achten Sie bei der Dachmontage darauf, unterhalb der Module ausreichend Belüftungsspielraum für eine Kühlung der
Rückseite (Laminat) zu lassen (mindestens 70 mm Abstand), bei Falzdächern ist die Tiefsicke ausschlaggebend.
Der Abstand zwischen den einzelnen Modulen muss mindestens 10 mm betragen. Zur Berücksichtigung der
thermischen Längenausdehnung des Modulrahmens empfiehlt die IBC SOLAR AG den Abstand zwischen zwei
Modulen auf 20 mm zu erweitern.
Stellen Sie immer sicher, dass die Modulrückseite nicht in Berührung mit fremden Gegenständen oder
Gebäudeelementen kommt – insbesondere, wenn das Modul mechanisch belastet wird.
IBC SOLAR AG lässt mehrere Montageverfahren zu. Ausführliche Angaben zu den zulässigen Montageverfahren mit
den zulässigen Klemmbereichen können Sie den Zeichnungen auf Seite 15 entnehmen!
Bei Verwendung der Montagebohrungen ist darauf zu achten, das als Standard die Montagebohrungen Verwendung
finden, die innerhalb der Klemmbereiche liegen. Montagebohrungen außerhalb der Klemmbereiche dienen als
zusätzliche Befestungsmöglichkeiten z.B. bei hohen Schneebelastungen.
Wenn Sie Montageverfahren einsetzen wollen, die nicht in der Zeichnung beschrieben werden, wenden Sie sich bitte
zwecks Genehmigung an IBC SOLAR AG. Andernfalls verlieren die Garantie und die Modulzertifizierung ihre Gültigkeit.
Befolgen Sie neben den Anweisungen des Installationshandbuches immer auch die Installationsanweisungen des
Herstellers der Aufständerungen. In Fällen, in denen die Anweisungen dieses Herstellers strikter sind als diejenigen des
Installationshandbuches, haben sie Vorrang vor diesen.
IAED-V241119 Seite 11 von 21
Falls die vom Montagegestellhersteller angegebene zulässige Maximallast unter dem der im Installationshandbuch
angegebenen Werte liegt, ist immer die Maximallastangabe des Montagegestellherstellers bindend.
Stellen Sie sicher, dass die Module nicht über die maximale Belastungsgrenze (siehe Kapitel 3.4) hinaus belastet werden
und dass sie infolge der Wärmeausdehnung der tragenden Struktur keinen übermäßigen Kräften ausgesetzt werden.
Die Solarmodule so befestigen, dass sie allen zu erwartenden Lasten und witterungsbedingten Einflüssen standhalten.
Die Maximallasten gelten für einheitlich verteilte Belastung durch Wind und/oder Schnee. Vermeiden Sie es, die Module
in Bereichen zu montieren, in denen die Gefahr von rutschendem Schnee, Eiszapfen oder Eisbildung besteht. Eventuell
auftretende Schneeabtriebslasten sind gesondert zu ermitteln. Erforderlichenfalls sind Maßnahmen zu ergreifen, um
Beschädigungen zu vermeiden.
Nähere Informationen zu den Lastfreigaben sind im Kapitel 3.4 zu finden.
Die Befestigung des Solarmoduls kann mit Klemmen oder alternativ direkt an den Montagelöchern (Position der
Montagebohrungen entsprechend Datenblatt) erfolgen. Es wird empfohlen, zur Befestigung der Module ausschließlich
IBC-Modulklemmen der verschiedenen aktuellen Baureihen zu verwenden. Diese Modulklemmen sind im
Zusammenspiel mit den Modulen getestet und freigegeben worden. Bei Verwendung von Modulklemmen ist allgemein
darauf zu achten, jegliche Schäden am Modul zu vermeiden und eine ausreichende Verbindung zwischen Klemme und
Modul herzustellen. Die korrekte Montage für eine ausreichende Verbindung der Modulklemmen wird in den
Montageanleitungen der IBC-Halterungsprodukte erklärt. Es ist darauf zu achten, jegliche Schäden am Module zu
vermeiden und eine ausreichende Verbindung zwischen Klemme und Modul herzustellen.
Zur Montage nur korrosionsfreie Schrauben, Muttern und Unterlegscheiben verwenden
Insbesondere in exponierten Lagen ist ein ausreichender Blitzschutz zu empfehlen. Eine Integration in bestehende
Blitzschutzeinrichtungen muss unter Beachtung der gültigen Vorschriften erfolgen.
Solarmodule nur hochkant, mit der Anschlussdose nach oben, oder quer montieren.
Bei der Aufständerung ist sicherzustellen, dass kein Regen- oder Kondenswasser in Richtung der Kabel-
Verschraubungen der Anschlussdosen laufen kann.
Das Solarmodul darf nicht im Stau- oder Kondenswasser stehen.
Die Module müssen innerhalb der Klemmbereiche spannungs- und verwindungsfrei flächig auf der Unterkonstruktion
befestigt werden.
Die Klemmung darf nur symmetrisch und muss an 4 Punkten erfolgen.
Die Klemmen dürfen das Frontglas der Module nicht berühren. Eine Deformation oder Beschädigung des Rahmens
muss ausgeschlossen sein.
IAED-V241119 Seite 12 von 21
Stellen Sie sicher, dass die Klemmen das Solarmodule nicht verschatten.
3.4 Montage Varianten
3.4.1 Klemmung an der kurzen und langen Seite
Klemmung lange Seite
Klemmung kurze Seite
IAED-V241119 Seite 13 von 21
A
B
Modultyp
Testlast
Druck/Zug [Pa]
Designlast *
Druck/Zug [Pa]
Testlast
Druck/Zug [Pa]
Designlast *
Druck/Zug [Pa]
IBC Module Transparent xxx ES-TA1
1762 x 1134 x 30 mm
0-270 mm
1600 / 1600
270-340 mm
5400 / 2400
340-440 mm
4800 / 2400
0-100 mm
1800/1800
0-270 mm
1067 / 1067
270-340 mm
3600 / 1600
340-440 mm
3200 / 1600
0-100 mm
1200/1200
0-220 mm
2400 / 1200
300-400 mm
4800 / 1200
0-220 mm
1600 / 800
220-280 mm
3200 / 800
IBC MonoSol xxx GS10-HC-N
1722 x 1134 x 30 mm
100-200 mm
2400/2400
200-316 mm
3600/2400
100-200 mm
1600/1600
200-316 mm
2400/1600
0-250 mm
2400 / 2400
0-250 mm
1600 / 1600
316-416 mm
5400/2400
190-300 mm
3600 / 2400
316-416 mm
3600/1600
190-300 mm
2400 / 1600
50-150 mm
3600 / 1600
50-150 mm
2400 / 1067
IBC Module Bifacial xxx LS-TA1
1722 x 1134 x 30 mm
300-400 mm
5400 / 2400
300-400 mm
3600 / 1600
150-260 mm
5400 / 1600
150-260 mm
3600 / 1067
400-540 mm
3600 / 2400
190-300 mm
3600 / 2400
400-540 mm
2400 / 1600
190-300 mm
2400 / 1600
260-360 mm
3600 / 1600
50-150 mm
3600 / 1600
260-360 mm
2400 / 1067
50-150 mm
2400 / 1067
IBC Module Transparent xxx LS-TA2
1762 x 1134 x 30 mm
300-400 mm
5400 / 2400
300-400 mm
3600 / 1600
150-260 mm
5400 / 1600
150-260 mm
3600 / 1067
IBC Module White xxx MS-TA1
IBC Module Black xxx MS-TA1
1762 x 1134 x 30 mm
400-540 mm
3600 / 2400
260-300 mm
2400 / 2400
300-450 mm
5400 / 2400
450-500 mm
2400 / 2400
400-540 mm
2400 / 1600
260-300 mm
1600 / 1600
300-450 mm
3600 / 1600
450-500 mm
1600 / 1600
260-360 mm
3600 / 1600
100-240 mm
2400 / 2400
260-360 mm
2400 / 1067
100-240 mm
1600 / 1600
Hinweis:
* Lasten gemäß IEC 61215-2:2016; max. zulässige Last entspricht der Planungslast/Designlast. Es gilt Designlast = Testlast /
Sicherheitsfaktor 1,5
Der Klemmbereich definiert den Abstand zwischen Modulaußenkante und der Mitte der Modulklemme
IAED-V241119 Seite 14 von 21
3.4.2 Einlegesystem lange und kurze Seite
Einlegesystem lange Seite
Einlagesystem kurze Seite
Modultyp
Einlegesystem lange Seite
Testlast
Druck/Zug [Pa]
Designlast *
Druck/Zug [Pa]
Einlegesystem kurze Seite
Testlast
Druck/Zug [Pa]
Designlast *
Druck/Zug [Pa]
IBC Module Transparent xxx ES-TA1
1762 x 1134 x 30 mm
IBC MonoSol xxx GS10-HC-N
1722 x 1134 x 30 mm
IBC Module Bifacial xxx LS-TA1
1722 x 1134 x 30 mm
IBC Module Transparent xxx LS-TA2
1762 x 1134 x 30 mm
2400 / 2400 1600 / 1600 1600 / 1600 1067 / 1067
3600 / 2400 2400 / 1600 2400 / 2400 1600 / 1600
3600 / 2400 2400 / 1600 1800 / 1800 1200 / 1200
3600 / 2400 2400 / 1600 2400 / 2400 1600 / 1600
IBC Module White xxx MS-TA1
IBC Module Black xxx MS-TA1 2400 / 2400 1600 / 1600 1200 / 1200 800 / 800
1762 x 1134 x 30 mm
Hinweis:
* Lasten gemäß IEC 61215-2:2016; max. zulässige Last entspricht der Planungslast/Designlast. Es gilt Designlast = Testlast /
Sicherheitsfaktor 1,5
IAED-V241119 Seite 15 von 21
3.4.3 IBC AeroFix G3 (Flachdachsystem)
AeroFix G3
Modultyp
Testlast
Druck/Zug [Pa]
Designlast *
Druck/Zug [Pa]
IBC Module Transparent xxx ES-TA1
1762 x 1134 x 30 mm
IBC MonoSol xxx GS10-HC-N
1722 x 1134 x 30 mm
IBC Module Bifacial xxx LS-TA1
1722 x 1134 x 30 mm
IBC Module Transparent xxx LS-TA2
1762 x 1134 x 30 mm
1400 / 1400 930 / 930
1400 / 1400 930 / 930
1800 / 1800 1200 / 1200
1600 / 1600 1067 / 1067
IBC Module White xxx MS-TA1
IBC Module Black xxx MS-TA1
1600 / 1600 1067 / 1067
1762 x 1134 x 30 mm
Hinweis:
* Bitte beachten Sie die gültige IBC AeroFix Installationsanleitung. Eckpunktklemmung an der kurzen Rahmenseite mit
Klemmbereich C, Klemmbereich definiert den Abstand zwischen Modulaußenkante und der Mitte der Modulklemme.
** Lasten gemäß IEC 61215-2:2016; max. zulässige Last entspricht der Planungslast/Designlast. Es gilt Designlast = Testlast /
Sicherheitsfaktor 1,5
IAED-V241119 Seite 16 von 21
4. Wartung und Pflege
Eine regelmäßige Wartung der Module ist nicht erforderlich. Es wird jedoch empfohlen, die Module regelmäßig auf
Schäden an der Glasoberfläche, der Rückseitenfolie, dem Rahmen, der Anschlussdose und den elektrischen
Außenanschlüssen zu untersuchen. Die elektrischen Anschlüsse sollten auf lose Verbindungen und Rostbildung hin
untersucht werden.
PV-Module sind selbst dann effizient im Betrieb, wenn sie niemals abgewaschen werden. Gleichwohl lässt sich die
Ausgangsleistung durch die Beseitigung von Schmutz auf der Glasoberfläche erhöhen. Staub, Schmutz oder andere
Rückstände auf der beschichteten Glasoberfläche können regelmäßig mit Wasser abgewaschen oder abgespült
werden. Hartnäckige Verschmutzungen auf dem beschichteten Glas können mit einem Mikrofasertuch und phneutralem
Reiniger oder mit einem handelsüblichen Glasreiniger entfernt werden.
Die Glasoberfläche darf keinesfalls mit aggressiven Reinigungsmitteln, Scheuermitteln oder Chemikalien behandelt
werden. Verwenden Sie ausschließlich ph-neutrale Reinigungsmittel.
Tragen Sie beim Warten, Waschen oder Reinigen der Module immer Gummihandschuhe, um sich zu isolieren und vor
elektrischen Schlägen zu schützen.
IAED-V241119 Seite 17 von 21
5. Reinigung der Module
Die Glasoberfläche der Module reinigt sich in der Regel durch Regenwasser selbst. Dennoch kann es sein, dass durch
beispielsweise eine eher geringe Dachneigung eine Reinigung notwendig werden kann. In diesem Fall folgen Sie bitte den
nachfolgenden Anweisungen.
Verzichten Sie auf eine Reinigung bei Frostgefahr sowie starken Temperaturunterschieden zwischen Modul, Luft und Wasser.
Idealerweise reinigen Sie die Solarmodule am frühen Morgen oder am späten Abend, bei niedriger Einstrahlung und mittleren
Temperaturen. Vermeiden Sie es die Module an heißen und sonnigen Tagen, mittags und bei starker Einstrahlung und hohen
Temperaturen zu reinigen. Die Modultemperatur sollte zwischen 10° und 30 °C liegen.
Verwenden Sie folgende Reinigungsmittel:
Weicher Lappen
Putzlappen oder Aufnehmer
Fensterscheibenabzieher
Handelsüblicher Glasreiniger (mit geringer Alkoholkonzentration)
Unkonzentrierter, PH-neutraler Reiniger
Wasser und milde Seife
Vermeiden Sie folgende Reinigungsmittel:
Drahtbürsten, Stahlwolle oder scharfkantige Werkzeuge, die das Glas zerkratzen können
Hochdruckreiniger
Reinigen mit Ammoniak oder anderen alkalischen Produkten
Scheuernde Reinigungsmittel
Lösungsmittel wie Benzin, Azeton, hochkonzentrierten Alkohol oder organische Verbindungen
Jegliche Art von Schleifpaste, sowie Auto- oder Metallpolitur
IAED-V241119 Seite 18 von 21
6. Transport und Lagerung
Setzen Sie das Modul nicht hart auf einer Oberfläche ab. Seien Sie besonders behutsam, wenn das Modul auf einer
Kante abgestellt wird.
Bei Lagerung und Transport muss sichergestellt sein, dass jedes Solarmodul ausreichend unterstützt wird.
Benutzen Sie einen Glassauger zur Entnahme und zum Transport eines Moduls oder halten Sie das Modul
ausschließlich am Modulrahmen. Transportieren Sie das Modul über längere Strecken nur senkrecht.
Die Module dürfen nicht an einem einzelnen Rahmenteil ergriffen und transportiert werden.
Heben oder bewegen Sie das Modul unter keinen Umständen an den Anschlussleitungen oder an der Anschlussdose.
Lassen Sie die Module nicht fallen.
Legen Sie keine Gegenstände auf den Modulen ab.
Bearbeiten Sie die Module nicht mit spitzen Gegenständen.
Bearbeiten Sie die Module nicht mit spitzen Gegenständen.
Beim Abstellen oder dem Transport der einzelnen Module zur unmittelbaren Montagestelle (z. B. Dach) ist jegliche
Beschädigung des Moduls zu vermeiden.
7. Entsorgung
Defekte oder alte Solarmodule sind fachgerecht zu entsorgen. Sie dürfen nicht über den Hausmüll beseitigt werden, sondern
nach den gültigen Entsorgungsvorschriften für Elektronikschrott.
IAED-V241119 Seite 19 von 21
8. Haftungsvorbehalt
IBC SOLAR AG hat keinen Einfluss auf die Nutzung dieses Sicherheits-, Installations- und Betriebshandbuchs und die
Bedingungen und Verfahrensweisen bei Installation, Betrieb, Nutzung und Wartung des Moduls. Deshalb übernimmt IBC SOLAR
AG keine Verantwortung für Verluste, Schäden, Verletzungen oder Kosten, die ggf. durch Installation, Betrieb, Nutzung und
Wartung des Moduls oder in Verbindung damit verursacht werden und weist die Haftung für solche Fälle ausdrücklich zurück.
IBC SOLAR AG übernimmt keine Verantwortung für Patentverletzungen oder sonstige Verletzungen von Rechten Dritter, die ggf.
durch die Nutzung des Moduls verursacht werden. Die Nutzung beinhaltet keine implizite oder anderweitige Lizenzgewährung
gemäß irgendeinem Patent oder Patentgesetz. Die Informationen in diesem Handbuch beruhen auf Kenntnissen und
Erfahrungen von IBC SOLAR AG und werden für zuverlässig befunden. Informationen, Produktspezifikationen (ohne
Einschränkung) und Vorschläge haben jedoch weder explizit noch implizit Garantiecharakter. IBC SOLAR AG behält sich das
Recht vor, Änderungen am Produkt, den Spezifikationen oder diesem Handbuch ohne vorherige Ankündigung vorzunehmen.
IAED-V241119 Seite 20 von 21