Pin assignment<br />

Pin 1=shield<br />

Pin 2=data- =blue<br />

Pin 3=data+=red<br />

Varyscan 3Special 250MSD<br />

<strong>2.</strong>4 DMX wiring<br />

Useashieldedtwisted-paircableto connecttheseriallink.Forshortdistances a<br />

microphonecable maybeused.<br />

Use 3-pinXLRconnectors.<br />

Thepin assignment isthesameforallVaryscans in line.<br />

3<br />

1<br />

2<br />

signal cable<br />

Iftheoutputsocketofthecontroldesks offersa5pinXLRfemale socket,<br />

pin 4and5arenotoccupied.<br />

Connect the DMX-out ofthecontroldesktothefirstVaryscaninline.<br />

(<strong>lighting</strong>control deskDMX-Out /VaryscanDMX-In).Connectthesecond<br />

Varyscanto thefirstinline,andsoon(Varyscan2DMX-In/Varyscan1<br />

DMX-Out). The DMX-Out of thelastunitinlineisnotoccupiedunless<br />

problemsoccure. Then useaterminationplug with thelastVaryscan inline.<br />

(XLR-connectorwitha 120Ohmresistor soldered between pin 2andpin 3).<br />

Problemsmight occurewhen thelineis overloaded, e.g.<br />

<strong>2.</strong>5 Poweringthefixture<br />

Installapluglike describedin <strong>2.</strong>1.<br />

Connected load: Voltage 230Volts, frequence50Hz,power740VA(3,2A)<br />

Useapowersupplyofatleast920VA(4A)perunit,asthefixtureneedmore<br />

power duringthe processofpoweringup.<br />

Connect the fixture to apropperinstalledgroundedsystem only. If anydoubts<br />

ontheelectricalinstallationsoccur,consultaqualifiedelectrician.<br />

In caseofdamagesoccuringduetoanotpropperinstalledelectricalsystem,<br />

warranty claims will beinvalidated.<br />

Don´t use fixtures when topcover is notfixed propperly. Contactwithelectronical<br />

parts can result inrisk for life. (Electrical shock 5000V)<br />

Connect fixtureonly after assuringthattheelectricalinstallationfits yourdemands<br />