UI-Kennlinienmeßgerät für Solarmodule und -generatoren

pvengineering

UI-Kennlinienmeßgerät für Solarmodule und -generatoren

PVPM Users Manual Page 58

Appendix A

14 Appendix A

14.1 Display lamps in the panel:

Mark Function

Charge Lights up, when accu is charged

State of Charge Lights up red, when accu is discharged (charge necessary at once)

Lights up green, when accu is ready

Lights up yellow, when accu charge is finished

Grid connection Lights up, when grid is connected and switched on

On Lights up, when device is powered on (readiness is displayed on LCD

screen)

14.2 Speaker signals:

PVPM1000C reports messages and operation state by speaker

signals: in the following deep sounds are represented by „da“,

higher sounds by „dee“.

Sound Meaning Reaction

Click „key click“ is simulated while you press a key -dee

During operation: signals start or end of an function -da

Error (common) Pay attention to further statements

about the kind of error

de If this signal comes with the first appearance of the

main menu, the device is ready

Device is ready

da or da-da Directly after switching power on: processor is o.k. -da

or da-da followed by Directly after switching power on: the lithium battery Service required

da-da

of the processor is empty.

dee-dee-da-da LCD display does not react Switch the device off and after a

little while on. If the error appears

again, service is necessary

dee dee After file transfer to PVPM (service only) File transfer to PVPM o.k.

da-dee-da After file transfer to PVPM (service only) File transfer to PVPM not o.k., rest

of destination file will be deleted

dee-dee-dee-dee During measurement. irradiation is too low or varies Measurement is incorrect an will be

dropped

dee-dee-dee-da-da-da- A/D converter could not be initialized

dee-dee-dee