24.03.2013 Views

Glen-Gery Regent Bricks - Glen-Gery Brick

Glen-Gery Regent Bricks - Glen-Gery Brick

Glen-Gery Regent Bricks - Glen-Gery Brick

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Tall, slender structural single wythe walls for commercial, educational, institutional and multi-family residential applications<br />

6"<br />

®<br />

• Exceptional structural and veneer building solution<br />

• Faster masonry construction<br />

• Inviting textures and dramatic colors<br />

2" 2" 2"<br />

3-1/2"<br />

BEARING PLATE DETAIL<br />

WATER REPELLENT CHEMICAL<br />

3-1/2"<br />

BASE FLASHING DETAIL<br />

© 2009 <strong>Glen</strong>-<strong>Gery</strong> Corporation 05/09 LUG<br />

<strong>Glen</strong>-<strong>Gery</strong> <strong>Regent</strong> <strong><strong>Brick</strong>s</strong><br />

THROUGH-WYTHE FLASHING ABOVE JOIST WHERE UNGROUTED<br />

REBAR & GROUT<br />

REBAR & GROUT<br />

H OLLOW C LAY B RICK U NITS AND W ALL D ESIGN<br />

• Units can be insulated and grouted<br />

• Exceeds industry standards<br />

• Beautiful appearance and structural integrity<br />

THROUGH-WYTHE FLASHING IN UNGROUTED CORES<br />

OVER BOND BEAMS<br />

8" HIGH BOND BEAM<br />

- 2 UNITS HIGH<br />

- BOTH COURSES FULLY GROUTED<br />

- 1 #5 BAR (d = 5-1/16")<br />

- 1-1/2" RECTANGLE WIRE CUT AT FACTORY<br />

(SEE BELOW)<br />

1-1/2"<br />

MESH TO CONTAIN GROUT<br />

BEARING DETAIL<br />

WALL<br />

HEIGHT<br />

REBAR & GROUT<br />

EXPANSION JOINT<br />

8" FROM CORNER<br />

REGENT Hollow Clay <strong>Brick</strong> Units<br />

7-5/8" (w) x 3-5/8" (h) x 11-5/8"(l)<br />

f'm = 4500 p.s.i.<br />

UNIT<br />

WIDTH<br />

1401 Broadway Street • P.O. Box 306 • Marseilles, IL 61341 • 800.441.6911<br />

14' 14' 4'<br />

REINFORCING REINFORCING<br />

20 PSF WIND 15 PSF WIND<br />

28'- 0" 7-5/8" #7 @ 32" O.C. #7 @ 48" O.C.<br />

2002 WITH ASD WITH 1/3 STRESS INCREASE<br />

REGENT Hollow clay units with type S mortar<br />

32'<br />

BOND BEAMS FOR TEMPORARY WALL<br />

BRACING DURING CONSTRUCTION


<strong>Glen</strong>-<strong>Gery</strong> <strong>Regent</strong> <strong><strong>Brick</strong>s</strong> H OLLOW C LAY B RICK U NITS AND W ALL D ESIGN<br />

REBAR & GROUT<br />

THROUGH WALL<br />

FLASHING TURNED<br />

UP 6"<br />

DRIP EDGE<br />

LEDGER DETAIL<br />

MINIMUM 3" BEARING<br />

1-1/2" DWC<br />

1-1/2"<br />

DRYWALL<br />

2-1/2" RIGID<br />

INSULATION WITH<br />

JOINTS TAPED<br />

WITH 8" PRECAST HOLLOW CORE FLOORING<br />

Total Wall<br />

R-Value 20.59<br />

© 2009 <strong>Glen</strong>-<strong>Gery</strong> Corporation 05/09 LUG<br />

THROUGH-WYTHE FLASHING<br />

2" CONCRETE TOPPING<br />

8" PRECAST PLANKS<br />

2" DEPTH UNITS (CUT)<br />

1/2" INSULATION<br />

8" DEPTH – 8" HIGH BOND BEAM<br />

2 COURSES HIGH<br />

GROUTED SOLID<br />

MESH TO CONTAIN GROUT<br />

REGENT HOLLOW CLAY UNITS<br />

7-5/8" X 3-5/8" X 11-5/8"<br />

MINIMUM 3" BEARING<br />

1-1/2" DWC<br />

FOR ELEC. ROUGH IN<br />

1/2" DRYWALL<br />

2-1/2" RIGID<br />

INSULATION WITH<br />

JOINTS TAPED<br />

WATER REPELLANT<br />

2 COURSE HIGH BOND BEAM<br />

REINFORCED & GROUTED<br />

EXTERIOR BEARING WALL DETAIL – 10" PRECAST HOLLOW CORE FLOORING<br />

REGENT BRICK<br />

1401 Broadway Street • P.O. Box 306 • Marseilles, IL 61341 • 800.441.6911<br />

RIGID INSULATION<br />

HAT CHANNELS<br />

DRYWALL<br />

LEDGER JOIST<br />

1/2" DIAMETER ANCHOR BOLTS 16" O.C.<br />

STAGGERED IN BOND BEAMS<br />

THROUGH-WYTHE FLASHING<br />

CUT UNIT<br />

2" CONCRETE TOPPING<br />

10" PRECAST PLANKS<br />

2" DEPTH UNITS (CUT)<br />

1/2" INSULATION<br />

8" DEPTH – 8" HIGH BOND BEAM<br />

2 COURSES HIGH<br />

GROUTED SOLID<br />

MESH TO CONTAIN GROUT<br />

REGENT HOLLOW CLAY UNITS<br />

7-5/8" X 3-5/8" X 11-5/8"<br />

THROUGH-WYTHE FLASHING


<strong>Glen</strong>-<strong>Gery</strong> <strong>Regent</strong> <strong><strong>Brick</strong>s</strong> H OLLOW C LAY B RICK U NITS AND W ALL D ESIGN<br />

Features<br />

Lower construction costs.<br />

The masonry walls are the<br />

structure and the structure is<br />

the exterior finish. No steel<br />

or concrete frames and no<br />

separate cladding. One trade.<br />

No delays for the design of<br />

steel and concrete connections.<br />

Interesting, durable,<br />

colors—clay colors do<br />

not fade.<br />

Over time, acid rains erode<br />

the cement paste and pigments<br />

of concrete masonry units.<br />

This erosion exposes the colors<br />

of the aggregates, muting the<br />

basic color of the concrete<br />

masonry units. Acid rain DOES<br />

NOT affect <strong>Regent</strong>s.<br />

Smaller scale.<br />

Compare <strong>Regent</strong> brick to larger<br />

units which often appear too<br />

large for structures and look<br />

like colored masonry.<br />

Lower weight.<br />

<strong>Regent</strong>s are less fatiguing to<br />

lay. They can also be laid<br />

with one hand rather than<br />

two for greater productivity<br />

and less cost.<br />

Higher compressive<br />

strength.<br />

At least 60% greater than a<br />

high-strength concrete masonry<br />

unit laid in Type “S” mortar.<br />

Walls can be taller for a given<br />

thickness or thinner for a<br />

given height.<br />

Easy to clean.<br />

<strong>Regent</strong>s are easy to clean with<br />

common cleaning chemicals<br />

while cleaning concrete<br />

masonry units requires a great<br />

deal of care, time, special<br />

chemicals and extra cost.<br />

© 2009 <strong>Glen</strong>-<strong>Gery</strong> Corporation 05/09 LUG<br />

CONCRETE OR LIMESTONE COPING<br />

CAP FLASHING<br />

REBAR @ GROUT<br />

THROUGH WALL<br />

FLASHING<br />

DRIP EDGE<br />

CAP ANCHOR<br />

2 COURSE HIGH<br />

BOND BEAM LEDGER JOIST<br />

PARAPET DETAIL<br />

HAT CHANNELS<br />

DRYWALL<br />

DOOR OPENING DETAIL<br />

1401 Broadway Street • P.O. Box 306 • Marseilles, IL 61341 • 800.441.6911<br />

ROOF<br />

COUNTERFLASHING<br />

ROOF MEMBRANE<br />

ANCHOR BOLTS 16" O.C. STAGGERED<br />

RIGID INSULATION<br />

HAT CHANNELS @ 16" O.C. ATTACHED TO MASONRY<br />

DRYWALL<br />

2 COURSE HIGH BOND BEAM<br />

REINFORCED & GROUTED<br />

STAINLESS STEEL<br />

DRIP EDGE<br />

WEEP HOLES<br />

THROUGH WALL FLASHING<br />

TURNED UP 8"


<strong>Glen</strong>-<strong>Gery</strong> <strong>Regent</strong> <strong><strong>Brick</strong>s</strong> H OLLOW C LAY B RICK U NITS AND W ALL D ESIGN<br />

EXTERIOR BEARING WALL DETAIL – WOOD TRUSS FLOOR SYSTEM EXTERIOR BEARING WALL DETAIL – NON BEARING SECTION<br />

Facts<br />

JOIST HANGERS<br />

<strong>Glen</strong>-<strong>Gery</strong> <strong>Regent</strong>-sized clay bricks are<br />

7-5/8" thick x 3-5/8" high x 11-5/8" long.<br />

© 2009 <strong>Glen</strong>-<strong>Gery</strong> Corporation 05/09 LUG<br />

RED VELOUR<br />

Stretchers are stocked in four durable,<br />

non-fading colors: Red Velour, Saddle Velour,<br />

Sahara Velour and Walnut Velour from<br />

Marseilles. Bond beam units are also available.<br />

8" <strong>Regent</strong> <strong>Brick</strong><br />

COTTON SASH WEEP HOLES<br />

@ 24" O.C.<br />

THROUGH WALL FLASHING WITH<br />

STAINLESS STEEL DRIP EDGE<br />

2 COURSE HIGH BOND BEAM<br />

MESH TO CONTAIN GROUT<br />

#5 REBAR @ 48" O.C.<br />

WATER REPELLENT CHEMICAL<br />

All <strong>Regent</strong>s comply with the requirements of<br />

ASTM C652, Grade SW, Type HBS, Class H40V<br />

(just below 40% void).<br />

The stretchers weight is 15.5 lbs. each. 33<br />

bricks are packaged in each strap and there<br />

are three straps of 33 per cube.<br />

1401 Broadway Street • P.O. Box 306 • Marseilles, IL 61341 • 800.441.6911<br />

8" <strong>Regent</strong> <strong>Brick</strong><br />

COTTON SASH WEEP HOLES<br />

@ 24" O.C.<br />

THROUGH WALL FLASHING WITH<br />

STAINLESS STEEL<br />

DRIP EDGE<br />

STRAP ANCHOR @ 2' O.C.<br />

(FOR LATERAL SUPPORT)<br />

UNITS GROUTED TO FORM BOND<br />

BEAM<br />

MESH TO CONTAIN GROUT<br />

#5 REBAR @ 48" O.C.<br />

WATER REPELLENT CHEMICAL<br />

SAHARA VELOUR<br />

SADDLE VELOUR WALNUT VELOUR<br />

Red Velour bricks are cleaned with Diedrich<br />

202; Sahara Velour, Saddle Velour and Walnut<br />

Velour bricks with 202V.<br />

DISCLAIMER NOTICE<br />

This guide contains technical information on masonry wall systems. It provides some of the basic information required to properly design and detail these systems. This booklet does not cover all designs or<br />

conditions. The information presented illustrates only the principles that are involved. This information should be recognized as suggestions which, if followed with good judgement, should produce positive<br />

results. Final decisions on the use of information, details and materials as discussed in this booklet are not within the purview of the <strong>Glen</strong>-<strong>Gery</strong> <strong>Brick</strong>, and must rest with the project designer, owner, or both.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!