<strong>SAFT</strong> AMERICA INC.<br />

Component Maintenance Manual<br />

1159SCAV519-1<br />

Install the valve using wrench p/n 93365. (see Fig. 902)<br />

Check the packing (O-Ring) for condition.<br />

3. Checking the nuts for tightness<br />

Check that all nuts are correctly tightened:<br />

lower terminal nuts; torque 60 ± 8 in. lbs. (6.8 Nm)<br />

upper terminal nuts; torque after assembly: 113 in. lbs. (13 Nm)<br />

4. Checking the connector receptacle<br />

Check the connector receptacle pins for condition; replace the connector receptacle<br />

if the pins show any trace of arcing or excessive oxidization.<br />

5. Visual inspection of the temperature sensor harness assembly<br />

Visually check the temperature sensor harness and auxilliary connector receptacle<br />

for condition.<br />

Check in particular that:<br />

the thermistor is secure to the mounting plate,<br />

the connecting leads or cable between the connector receptacle and the<br />

various components are not damaged.<br />

6. Checking the thermostat<br />

A. Functional check (see Fig. 501)<br />

Dip the thermostats in a 0.5 liter (0.109 Imp. Gal; 0.132 US Gal.)<br />

beaker, three quarters full of water. Make sure that the thermostats<br />

are not in contact with the container walls.<br />

24-34-01<br />

PAGE 502<br />

AUG 30/96