Aravindhan
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Arivazhagan Aravindan<br />
From: vasu [vasu@hvksystems.in]<br />
Sent: Friday, March 29, 2013 3:08 PM<br />
To: Arivazhagan Aravindan<br />
Cc: 'HVK Planning'<br />
Subject: OFFER - EATON SMPS - HVK<br />
Attachments: APR 48 3G Catalogue.pdf; SC100 Controller.pdf; SM40_I.pdf; ST CMS-171.pdf<br />
Importance: High<br />
Kind Attn: Mr. Arivazhagan Aravindan<br />
Dear Sir,<br />
Thanks for the enquiry sent to us for Eaton SMPS. The given model code is obsolete. Hence we have quoted the<br />
current version model. Kindly consider our offer and arrange to release the purchase order at the earliest.<br />
Please find attached current version catalog for your kind perusal.<br />
Thanks & Best Regards,<br />
B.Vasudevan<br />
Mobile: 98407 85200<br />
HVK Systems & Marketing Pvt Ltd<br />
No.2, First Floor, Bhattad Tower<br />
30, Westcott Road, Royapettah<br />
Chennai - 600 014<br />
Phone: 044-2854 4031 / 2854 7047 / 2858 3893<br />
Fax: 044-2841 9248<br />
Email: vasu@hvksystems.in<br />
1
HVK SYSTEMS & MARKETING PVT. LTD.<br />
No: 2 First Floor, Bhattad Towers<br />
No: 30 Westcott Road, Royapettah<br />
Chennai - 600 014.<br />
Phone: 044-2858 3893 / 2854 7047<br />
Fax: 044-2841 9248<br />
E-Mail: Planning@hvksystems.in<br />
M/s. ST-CMS Electric Company Pvt Ltd<br />
250 MW Power Plant<br />
Uthangal Post<br />
Neyveli - 607 804<br />
Tamilnadu<br />
Kind Attention: Dr.S.P.A Aravindaan - Asst.Officer - Purchase<br />
Enquiry No: 2012-13 / 1030 dated: 18-03-2013<br />
Sl No Make Description<br />
Qty Rate Value<br />
1 Eaton Eaton Solution consist of following parameters<br />
• It will have 2 numbers of loaded APR48 3G Rectifier<br />
modules & 2 additional slots will be provided for future<br />
load expansion.<br />
• Controller will be either SM40 Controller or SC100<br />
• Please note in DC Distribution there will be provision to<br />
accommodate 6 nos. of 6-63 Amp MCBs.<br />
2 65580.00 131160.00<br />
131160.00<br />
9837.00<br />
6066.15<br />
127389.15<br />
TIN No: 3305 0720774 for HVK Systems & Marketing Pvt Ltd<br />
CST No: 43149 dt. 21-01-91<br />
Special Note:<br />
DC Distribution, there will be provision to accommodate<br />
6 nos. of 6-63 Amp MCBs. In order to provide detailed<br />
GA of the solution, we need information on the DC<br />
distribution (how many numbers & of which ratings MCB’s<br />
will be required in load & battery distribution.<br />
Sub Total<br />
Less: Discount @ 7.5%<br />
Add: VAT @ 5% against declaration form<br />
Grand Total (R.O)<br />
Terms & Conditions:<br />
a. Delivery: Within 8 weeks from the date of OA<br />
b. Payment Terms: 100% advance payment along-with<br />
purchase order<br />
c. Mode of Dispatch: Delivery by road<br />
d. Validity: 30 days from the offer date<br />
e. Frieght: On your account at actuals<br />
f. Warranty: 12 months from the date of commissioning<br />
or 13 months from the date of delivery whichever is earlier<br />
Quotation No:HVK/DLN/171<br />
Date: 29/03/2013
SC100 System Controller<br />
Features<br />
Powerware<br />
Comprehensive system control functions<br />
Supports PSTN and GSM external modems<br />
User-friendly menus<br />
Pre-loaded customized configuration file<br />
Complies with international standards<br />
Setup via DCTools configuration software<br />
Language options<br />
Low cost<br />
The SC100 System Controller<br />
is a control and monitoring<br />
solution for the Eaton 3G<br />
power solutions.<br />
It provides a full suite of system<br />
control functions including<br />
Temperature Compensation,<br />
Equalize and Fast Charge.<br />
A comprehensive range of<br />
alarms and alarm notification<br />
options are available,<br />
including SMS, relay contacts<br />
and modem dial out to<br />
PowerManagerII.<br />
The SC100 is supplied preconfigured<br />
with either a default<br />
configuration file, or with<br />
one factory customized for<br />
a particular application. This<br />
ensures fast and problem free<br />
installation.<br />
If on-site changes are needed<br />
then these can be easily made<br />
from the front panel or with a<br />
Windows PC using DCTools<br />
configuration software.<br />
The front panel incorporates<br />
a high-resolution back-lit LCD<br />
display with easy to read<br />
characters and easy to use<br />
menu system.<br />
All system values and alarms<br />
can be displayed and the keypad<br />
provides easy access to<br />
check or edit settings.<br />
The SC100 works with a separate<br />
system I/O board for<br />
powerful and user-friendly<br />
interfacing.<br />
Typical Applications<br />
24V and 48V power<br />
systems<br />
Wireless cell sites and<br />
switches<br />
Transmission terminals<br />
Options<br />
External GSM or PSTN<br />
modem Control and Monitoring
Technical Specifications<br />
Brief Technical Specifications: SC100 plus IOBGP<br />
Supply Voltage Range<br />
19 to 60V DC<br />
Operating Range -10 to +70 °C [14 to 158 °F ]<br />
Input/Output with IOBGP-00<br />
Analog inputs: Current sensor (3), Bus voltage (1),<br />
Temperature (2)<br />
Digital inputs: 4 Internal (pre-defined), 6 external<br />
(user-defined)<br />
LVD contactor outputs (2)<br />
Relay outputs: 6<br />
Voltage free, NO-C-NC, 0.5A @ 100VDC<br />
Screw terminal block, 0.5mm2 - 2.0mm2 conductors<br />
Communications Interfaces<br />
Physical: RS232<br />
Software: S3P, MII<br />
Management software: DCTools configuration / local<br />
management software.<br />
PowerManagerII remote management software.<br />
Display Back-lit dot matrix LCD 128 x 128 pixel<br />
Adjustable viewing angle<br />
Keypad 4 keys<br />
Language Options English: Standard<br />
Other languages: by arrangement.<br />
Indicators Power on<br />
Critical/major alarm<br />
Minor alarm<br />
Dimensions H,W,D SC100: width 44.5mm, depth 60mm, height 133.5mm (3U)<br />
IOBGP: width 175mm, depth 18mm, height 106mm<br />
Mounting: SC100: rectifier slot<br />
flush panel mount<br />
vertical or horizontal orientation<br />
IOBGP panel mount<br />
Datalogging 100 record Event Log<br />
Options<br />
Modem communications<br />
PSTN or GSM. Requires external modem.<br />
Certifications<br />
All products comply with International Standards. Contact your local Powerware DC representative<br />
for details on the specific product versions available with these safety and EMC<br />
approvals:<br />
China<br />
North America<br />
Europe<br />
Australia / New Zealand<br />
MII<br />
FCC Verification, IC<br />
CE<br />
C-tick<br />
In the interests of continual product improvement all specifications are subject to change<br />
without notice.<br />
Email: dc.info@eaton.com<br />
Internet: www.powerware.com<br />
SC100/IOBGP C
Features<br />
SM40 Supervisory Module<br />
Pre-Loaded Configuration File<br />
Temperature Compensation<br />
Serial Control (24 rectifiers)<br />
Battery Test<br />
Controls up to two Low Voltage Disconnects (LVD)<br />
Battery Current Limiting<br />
Interfaces to SiteSure Input/Output Modules<br />
Multi language options<br />
Set-up via keypad or DCTools configuration software<br />
Compliance with International Standards<br />
Local, PSTN or GSM communications options<br />
Datalogging<br />
The SM40 microprocessorbased<br />
system supervisory<br />
modules provide the control<br />
and monitoring functions for<br />
the Powerware Access Power<br />
Solutions range of DC power<br />
systems.<br />
The SM40 supervisory module<br />
is supplied factory-preconfigured,<br />
ready for immediate<br />
use. All system parameters<br />
are stored in transferable<br />
configuration files for convenient<br />
management of system<br />
set-up. The SM40 can also be<br />
re-configured on-site using the<br />
Windows compatible DCTools<br />
configuration software via the<br />
front panel RS232 communication<br />
port.<br />
The SM40 supervisory module<br />
provides full control of<br />
system voltage, load current,<br />
status and alarms, which can<br />
be displayed and changed on<br />
the optional LCD display and<br />
keypad. The SM40 also offers<br />
modem control (PSTN and<br />
GSM), an audible alarm and<br />
battery test functionality.<br />
Using the GSM modem option<br />
status and alarm messages<br />
can be sent to any SMS text<br />
message compatible mobile<br />
phone.<br />
Supervisory Modules
Technical Specifications<br />
Brief Technical Specifications<br />
Supply Voltage Range<br />
18-60V<br />
Operating Range -10°C to +70°C [+14°F to +158°F]<br />
Input/Output Standard<br />
Analog Inputs: Current sensor/shunt (2), Bus Voltage<br />
(1), Temperature (2)<br />
Digital Inputs: Up to 6<br />
Relay Outputs: Up to 6 configurable, open-collectors.<br />
Relays fitted on system backplane or Interface PCB.<br />
Input / Output Optional (with SiteSure modules)<br />
Analog inputs: 6<br />
Digital inputs: 18<br />
Digital outputs: 8<br />
Communications Interface: RS232<br />
Software: PowerManagerII remote monitoring<br />
software<br />
DCTools configuration software (free download from<br />
www.powerware.com/downloads)<br />
Modems (optional): Supports PSTN or GSM external<br />
modems<br />
SMS messaging: System Status Messages and Alarms<br />
Messages. Requires external GSM modem.<br />
Display and keypad (optional)<br />
Display: Back-lit dot matrix LCD<br />
Keypad: Membrane type, 5 keys<br />
Indicators Power on<br />
Urgent Alarm<br />
Non-urgent alarm<br />
Datalogging 100 record Event Log<br />
In the interests of continual product improvement all specifications are subject to change<br />
without notice.<br />
Email: dc.info@eaton.com<br />
Internet: www.powerware.com<br />
SM40 I