02.04.2013 Views

The impact of urban groundwater upon surface water - eTheses ...

The impact of urban groundwater upon surface water - eTheses ...

The impact of urban groundwater upon surface water - eTheses ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

E<br />

>10<br />

VDC<br />

L<br />

TS<br />

R<br />

E<br />

L<br />

Surface<br />

(L1)<br />

T S<br />

T<br />

(E) (C)<br />

(B)<br />

1 2 5<br />

Figure 4.5 Pressure Logging System<br />

5 10<br />

vent tube<br />

5 core cable<br />

10 9 6<br />

EBC 3 2 1<br />

2<br />

V<br />

S<br />

9<br />

Down Hole<br />

Component Connections<br />

P<br />

3 1<br />

2<br />

Plastic body form +<br />

Heat shrink<br />

V.A<br />

V<br />

1<br />

3<br />

Poly eurethane<br />

potting compound<br />

4 3 2 1<br />

E - DC power supply > 10 VDC [in this case 2 x 9V DC batteries in series ]<br />

L - Data logger [ Gemini Tiny Talk (8 bit) voltage input,0-2.5 VDC ( RS#TK-0702)* 1 ,<br />

resolution 10 mv]L1 – trigger output<br />

Or [ ERTCO Volt101 (16 bit), 0-15 VDC ,no trigger (CP#U-38010-25)* 2 , resolution<br />

0.5 mv]<br />

T - Darlington small signal transistor [(RS#157-7157)] Gemini logger only<br />

S - Relay [Omron G5V-1, 5 VDC (RS#369-343)]<br />

V - Voltage Regulator 10 V [(RS#298-7151)]<br />

P - Pressure Transducer 0-5 psi [gauge, compensated, 0-50mv, (RS#286-6580]<br />

A - Amplifier [Burr-Brown, single supply micro power instrumentation amplifier<br />

(RS#285-8126)]<br />

R – Resistor to set the gain [Gain = 5+ 200k/R, used 4.7k but this may be altered for<br />

greater sensitivity <strong>of</strong> measurements over a smaller range.]<br />

*1 Radio Spares UK catalogue number * 2 Cole Palmer UK catalogue number<br />

Components V,P,A are located downhole. For this system a range <strong>of</strong> 3.3m provides a<br />

resolution <strong>of</strong> 1 cm with the Gemini and 1 mm with the ERTCO (however the ERTCO has<br />

no trigger system requiring power to be on all the time). With a total component price <strong>of</strong><br />

£100 the whole system can be constructed to fit a 20 mm ID piezometer and be concealed<br />

within a 13x13 cm stop cock cover<br />

P<br />

P<br />

A<br />

2<br />

4<br />

3<br />

2<br />

1<br />

2<br />

3<br />

4<br />

A<br />

5<br />

4<br />

7<br />

1<br />

8<br />

8<br />

7<br />

6<br />

5<br />

6<br />

15mm<br />

R

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!