HQD meters—technical data<br />

FEATURE METERS<br />

HQ11D HQ14D HQ30D flexi HQ40D multi<br />

Measurement Description 1 (pH) 1 (conductivity) 1 (pH or conductivity 2 (per channel, pH or<br />

channels or O2) conductivity or O2 or<br />

ISE)<br />

Oxygen Measuring range: 0.00 – 20.0 mg/l; 0 – 200% Automatic air Automatic air<br />

(LDO) Resolution: 0.01 oder 0.1 mg/l; pressure pressure<br />

0.1% saturation<br />

Accuracy: ± 1% of the measuring range<br />

compensation compensation<br />

pH Measuring range: 0 – 14<br />

Resolution: (selectable) 0.1/0.01/0.001<br />

Accuracy: ± 0.002<br />

Temperature compensation: automatic<br />

● ● ●<br />

Redox potential Measuring range: ± 1,500 mV<br />

Resolution: 0.1<br />

Accuracy: ± 0.1 mV<br />

● ● ●<br />

Ion Measuring range: electrode-dependent ●<br />

concentration Resolution: (selectable); max. 5 positions<br />

(ISE) 0.1/0.01/0.001<br />

Accuracy: ± 0.1 mV<br />

Conductivity Resolution: max. 5 positions, 2 decimal Measuring range: Measuring range: Measuring range:<br />

places 0.01 μS/cm – 0.01 μS/cm – 0.01 μS/cm –<br />

Temperature compensation: non-linear 200 mS/cm; 200 mS/cm; 400 mS/cm;<br />

(natural <strong>water</strong> in acc. with DIN 38404/ Accuracy: ± 0.5% Accuracy: ± 0.5 % Accuracy: ± 0.5%<br />

EN ISO 7888), non-linear (NaCl), (1 μS/cm – (1 μS/cm – (1 μS/cm –<br />

linear coefficient [numeric value]<br />

%/°C; no compensation<br />

200 mS/cm) 200 mS/cm) 400 mS/cm)<br />

Calibration With automatic reminder of calibration Max. 4 points 1 point pH max. 4 points pH max. 4 points<br />

and control standard Conductivity 1 point Conductivity 1 point<br />

O2 1 point O2 1 point<br />

ISE max. 5 points<br />

Autoread ● ● ● ●<br />

Status display<br />

Electrode<br />

● ● ● ●<br />

Interfaces Waterproof<br />

USB port for printer,<br />

PC, temperature,<br />

USB memory stick<br />

Password<br />

protection<br />

● ● ● ●<br />

Operating options Basic, detail, total (GLP)<br />

Data storage 500 measured values; manual or automatic data storage<br />

IDs For samples and users: alphanumeric, max. 12 characters; 12 sample and 20 user names;<br />

automatic registration of number of samples (0-999)<br />

Measurement<br />

mode<br />

Manual, interval, continuous; measurement methods editable<br />

Display Backlit graphic display; 240 x 160 pixel; automatic switch-off in energy saving mode; with date and time display.<br />

HQ40D only: simultaneous display of 2 parameters and temperature<br />

Power supply Mains power 115 V/250 V (power unit optional) 115 V/250 V;<br />

battery powered 4 AA batteries or rechargeable batteries (battery charger necessary)<br />

Protection rating IP 67 for meter, outdoor electrodes and connections<br />

Dimensions,<br />

weight<br />

95 x 197 x 36 mm (H x W x D), 323 g (without batteries)<br />