Ramsey MINI CK101 Weight Integrator - Hoferick Engineering GmbH
Ramsey MINI CK101 Weight Integrator - Hoferick Engineering GmbH
Ramsey MINI CK101 Weight Integrator - Hoferick Engineering GmbH
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Register Type<br />
Low<br />
Limit<br />
High Limit<br />
Refresh Time<br />
[ms]<br />
Format Address<br />
(word) Note<br />
RW 5 - integer 341<br />
Batch Option<br />
Preset<br />
CutOff Corr<br />
CutOff queue<br />
CutOff Len<br />
CutOddDev<br />
Start Delay<br />
Stabilization Time<br />
Batch Deviation<br />
Tab. 5 – Variables list<br />
RW<br />
RW<br />
RW<br />
RW<br />
RW<br />
RW<br />
RW<br />
RW<br />
RW<br />
Tab.44<br />
0<br />
Tab.45<br />
0<br />
Tab.46<br />
3.3 Description of Registers<br />
0<br />
0<br />
0<br />
0<br />
LOAD OUT MENU<br />
Tab.44<br />
10000<br />
Tab.45<br />
10000<br />
Tab.46<br />
10000<br />
600<br />
600<br />
100<br />
Below the description of the register and their use.<br />
23 - 56<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
integer<br />
float<br />
integer<br />
float<br />
float<br />
float<br />
integer<br />
integer<br />
integer<br />
Sim_Key The master has the possibility to send a key code to the instrument. Interpreted key<br />
codes are:<br />
Key<br />
UP ARROW<br />
DOWN ARROW<br />
RUN<br />
Tab 6 - key codes<br />
Key Code<br />
0048 H<br />
0050 H<br />
0052 H<br />
Write Flag Set to 0 after a message has been received and properly processed. If a message is<br />
correctly received but cannot be processed because password protection or size<br />
error, this flag is set to 1. The user may read this register after a write message to<br />
ensure the data have been accepted.<br />
Key<br />
F1<br />
F2<br />
F3<br />
357<br />
358<br />
360<br />
361<br />
363<br />
365<br />
367<br />
368<br />
369<br />
Key Code<br />
003F H<br />
0040 H<br />
0041 H