Your partner for high voltage technique ... for sure !<br />

<strong>Operating</strong> <strong>Manual</strong><br />

810268_810275BAL0400604aE.sxw<br />

Date: 17. Mai 2004<br />

<strong>Operating</strong> <strong>Manual</strong><br />

HV – Measuring lance<br />

HMG 04/02 Art. N°. 810268 (110kV)<br />

HMG 08/03 Art. N°. 810275 (160kV)<br />

Page: 1 of 12<br />

Fon: +49 70 72 / 91 43 -0<br />

www.schnier-elektrostatik.de<br />

<strong>SCHNIER</strong> <strong>Elektrostatik</strong> <strong>GmbH</strong><br />

Robert-Bosch-Str. 60<br />

72810 Gomaringen


Your partner for high voltage technique ... for sure !<br />

Contents<br />

1.0 General 1.1 Introduction<br />

1.2 Application area<br />

2.0 Safety 2.1 <strong>Operating</strong> safety - symbol<br />

2.2 Attention - tips<br />

2.3 Special operating safety tips<br />

2.4 General safety tips<br />

3.0 Technical data 3.1 General data<br />

3.2 Measuring ranges<br />

4.0 Construction of the 4.1 Overview<br />

instrument 4.2 Description<br />

5.0 Measuring operation 5.1 General<br />

5.2 HV - measuring<br />

6.0 Spare parts and 6.1 Spare parts<br />

accessories 6.2 Accessories<br />

6.3 Guarantee<br />

6.4 Our address for customers<br />

<strong>Operating</strong> <strong>Manual</strong><br />

810268_810275BAL0400604aE.sxw<br />

Date: 17. Mai 2004<br />

Page: 2 of 12<br />

Fon: +49 70 72 / 91 43 -0<br />

www.schnier-elektrostatik.de<br />

<strong>SCHNIER</strong> <strong>Elektrostatik</strong> <strong>GmbH</strong><br />

Robert-Bosch-Str. 60<br />

72810 Gomaringen


Your partner for high voltage technique ... for sure !<br />

1.0 General<br />

1.1 Introduction This operating manual (following to be called OM) has to be<br />

read, understood and noted in all and every point by all, who<br />

are responsible for the measuring instrument and the electrical<br />

plant.<br />

Because of these reasons, the OM has to be always handy<br />

for the operating, maintenance and servicing personnel.<br />

Only with the knowledge of this OM, mistakes can be avoided<br />

and a fault-free operation be guaranteed. It is therefore absolutely<br />

necessary that the OM present is to be known and fully<br />

understood by all those dealing in any form with this plant.<br />

Messrs. <strong>SCHNIER</strong> <strong>Elektrostatik</strong> <strong>GmbH</strong>, cannot be held responsible<br />

for any damages and faults originating from the<br />

fact to not have known this OM !<br />

1.2 Application area The HV-measuring lance is suitable for the measuring of<br />

D.C.- voltages in the range of 0 – 110kV, resp. 160kV, of<br />

positive and of negative polarity. The measuring is done<br />

either with the lance tip directly at the high voltage electrode<br />

or with a high voltage cable which instead of the measuring<br />

tip is plugged into the measuring lance.<br />

Moreover, the respective safety precautions according to<br />

item 2.3 and 2.4 of this OM have to be obeyed.<br />

<strong>Operating</strong> <strong>Manual</strong><br />

810268_810275BAL0400604aE.sxw<br />

Date: 17. Mai 2004<br />

The HV-measuring lance, type HMG 04/02, resp.<br />

HMG 08/03, may only be used in the area of electrostatic<br />

coating- and material separating plants<br />

Page: 3 of 12<br />

Fon: +49 70 72 / 91 43 -0<br />

www.schnier-elektrostatik.de<br />

<strong>SCHNIER</strong> <strong>Elektrostatik</strong> <strong>GmbH</strong><br />

Robert-Bosch-Str. 60<br />

72810 Gomaringen


Your partner for high voltage technique ... for sure !<br />

2.0 Safety<br />

2.1 <strong>Operating</strong> safety symbol<br />

2.2 Attention - tips<br />

All tips and hints which carry this symbol indicate dangers for<br />

life and health of persons if they do NOT obey said tips/hints.<br />

Please do take care of these tips and hints and pay special<br />

attention and precaution in those cases .<br />

Apart from said tips and hints appearing in this OM, the general<br />

safety and accident prevention regulations have to be<br />

obeyed as well.<br />

This “Attention!” appears on all places in this OM which have<br />

to be taken special care of in order to prevent any damage<br />

resp. the destroying of any equipment.<br />

2.3 Special safety tips The HV-lance may only be operated in electrostatic, stationary<br />

spray plants which conform to the resp. safety requirements:<br />

EN 50 176<br />

EN 50 177<br />

EN 50 223<br />

EN 50 348<br />

DIN VDE 0147 part 1<br />

Moreover, the operating manual of the resp. electrostatic<br />

equipment has to be obeyed as well!<br />

2.4 General safety tips See data sheet „Regulations and rules“N°. 810002SD01<br />

<strong>Operating</strong> <strong>Manual</strong><br />

810268_810275BAL0400604aE.sxw<br />

Date: 17. Mai 2004<br />

Page: 4 of 12<br />

Fon: +49 70 72 / 91 43 -0<br />

www.schnier-elektrostatik.de<br />

<strong>SCHNIER</strong> <strong>Elektrostatik</strong> <strong>GmbH</strong><br />

Robert-Bosch-Str. 60<br />

72810 Gomaringen


Your partner for high voltage technique ... for sure !<br />

3.0 Technical data<br />

3.1 General data Name of equipment: HV-measuring lance<br />

Type: HMG 04/02 (110kV)<br />

HMG 08/03 (160kV)<br />

Measuring resistance:10GOhm (HMG 04/02)<br />

20GOhm (HMG 08/03)<br />

Dimensions ø/L: 40 (120)mm / 750mm (HMG 04/02)<br />

40 (120)mm / 950mm (HMG 08/03)<br />

Weight: 1200g (HMG 04/02) approx.<br />

2000g (HMG 08/03) approx.<br />

Surr. conditions: +10°C up to +40°C, max. 80% r.h.<br />

Constr. type: IP40<br />

Length meas cable: 3m<br />

Length earth cable: 5m<br />

Serial N°.: see type plate<br />

Year/built: see type plate<br />

3.2 Measuring ranges High voltage: 110kV (HMG 04/02)<br />

160kV (HMG 08/03)<br />

Meas. exits: 4mm plug to connect with common<br />

voltage measuring instrument with<br />

10M-Ohm inside resistance.<br />

10V conforms to 100kV.<br />

Recommendation: FLUKE 110<br />

<strong>SCHNIER</strong>-Art.-N°.: 810258<br />

<strong>Operating</strong> <strong>Manual</strong><br />

810268_810275BAL0400604aE.sxw<br />

Date: 17. Mai 2004<br />

Page: 5 of 12<br />

Fon: +49 70 72 / 91 43 -0<br />

www.schnier-elektrostatik.de<br />

<strong>SCHNIER</strong> <strong>Elektrostatik</strong> <strong>GmbH</strong><br />

Robert-Bosch-Str. 60<br />

72810 Gomaringen


Your partner for high voltage technique ... for sure !<br />

4.0 Construction of the instrument<br />

4.1 Over view<br />

4<br />

3<br />

5<br />

2 <br />

1 Measuring tip 2 Measuring lance 3 Measuring cable<br />

4 Earth cable 5 Earth clamp<br />

4.2 Description<br />

4.2.1 Description The measuring tip consists of a measuring stick with insulating<br />

bushel and a 4mm bundle plug at the end. The measuring<br />

tip serves to measure the high voltage directly at the HV-electrode.<br />

It is screwed onto the measuring lance via a<br />

M4-thread. Instead of the measuring tip, a HV-cable with<br />

4mm bundle- or banana plug may be plugged in directly.<br />

<strong>Operating</strong> <strong>Manual</strong><br />

810268_810275BAL0400604aE.sxw<br />

Date: 17. Mai 2004<br />

Page: 6 of 12<br />

Fon: +49 70 72 / 91 43 -0<br />

www.schnier-elektrostatik.de<br />

<strong>SCHNIER</strong> <strong>Elektrostatik</strong> <strong>GmbH</strong><br />

Robert-Bosch-Str. 60<br />

72810 Gomaringen


Your partner for high voltage technique ... for sure !<br />

4.2.1 Measuring lance<br />

<strong>Operating</strong> <strong>Manual</strong><br />

810268_810275BAL0400604aE.sxw<br />

Date: 17. Mai 2004<br />

8<br />

9<br />

The measuring lance consists of the handle (10), the safety<br />

disk (9), the anode pipe (8) and the measuring connection<br />

bushel (11). The precision HV-measuring resistor is built into<br />

the handle (10) and fully protected against the influence of<br />

the electrostatic fields by the earthed metal bushel.<br />

The safety disk (9) saves the operator from shorts. Either the<br />

measuring tip or a HV-cable with 4mm plug may be installed<br />

into the anode pipe (8). The measuring cable (3) is plugged<br />

into the measuring connection socket (11). The earth cable<br />

(4) is also connected in the plug of the measuring cable (3).<br />

When operating the measuring lance, by all means the earth<br />

cable has to be connected to earth.<br />

Page: 7 of 12<br />

Fon: +49 70 72 / 91 43 -0<br />

www.schnier-elektrostatik.de<br />

10<br />

11<br />

<strong>SCHNIER</strong> <strong>Elektrostatik</strong> <strong>GmbH</strong><br />

Robert-Bosch-Str. 60<br />

72810 Gomaringen


Your partner for high voltage technique ... for sure !<br />

5.0 Measuring operation<br />

5.1 General Exact measurements require respective measuring conditions.<br />

Please take note that measurements taken near electro-magnetic,<br />

electrostatic fields or near powerful electrical<br />

disturbance fields may a negative influence on the measurement<br />

result. Especially during high voltage measuring the<br />

measuring instrument should be as far away from the electrical<br />

field as possible.<br />

5.2 HV-measurement The 4mm plug of the measuring cable (3) is to be plugged<br />

into the voltage measuring sockets of the voltage measuring<br />

instrument (red plug in ‘+’ and black plug in ‘-‘). Please take<br />

care that the DC-voltage measuring range is adjusted to the<br />

voltage measuring instrument. Please by all means follow<br />

the operating manual of the voltage measuring instrument.<br />

The three-pole plug of the measuring cable is to be plugged<br />

into the measuring lance.<br />

<strong>Operating</strong> <strong>Manual</strong><br />

810268_810275BAL0400604aE.sxw<br />

Date: 17. Mai 2004<br />

The earth cable has to be connected to earth !<br />

The measuring of high voltage may only be carried out<br />

by expert personnel. Only high voltage measurements on<br />

electrostatic coating- and / or material separating plants<br />

may be carried out. The HV-measuring lance, type<br />

HMG 04/02 and HMG 08/03 are NOT suitable for measurements<br />

of heavy power current-plants.<br />

The high voltage may be measured either directly at the<br />

HV-electrode with the measuring tip or via the HV-cable.<br />

With 100kV the indicator shows 10,0V, and with negative<br />

high voltage accordingly –10,0V.<br />

Page: 8 of 12<br />

Fon: +49 70 72 / 91 43 -0<br />

www.schnier-elektrostatik.de<br />

<strong>SCHNIER</strong> <strong>Elektrostatik</strong> <strong>GmbH</strong><br />

Robert-Bosch-Str. 60<br />

72810 Gomaringen


Your partner for high voltage technique ... for sure !<br />

6.0 Spare parts and accessories<br />

6.1 Spare parts<br />

Mesuring cable with earth cable<br />

Art.N°. 140059/001<br />

<strong>Operating</strong> <strong>Manual</strong><br />

810268_810275BAL0400604aE.sxw<br />

Date: 17. Mai 2004<br />

Measuring lance<br />

Art.N°. 800039/001<br />

(HMG 04/02)<br />

Art.N°. 800041/001<br />

(HMG 08/03)<br />

Page: 9 of 12<br />

Fon: +49 70 72 / 91 43 -0<br />

www.schnier-elektrostatik.de<br />

Measuring tip<br />

Art.N°. 810236<br />

<strong>SCHNIER</strong> <strong>Elektrostatik</strong> <strong>GmbH</strong><br />

Robert-Bosch-Str. 60<br />

72810 Gomaringen


Your partner for high voltage technique ... for sure !<br />

6.2 Accessories<br />

FLUKE 110 True RMS Multimeter Art.N°.: 810258<br />

- D.C.-voltage 600V 1mV ±(0,7%+2)<br />

- A.C.-voltage 600V 1mV ±(1,0%+3)<br />

- Resistor 40M 0,1Ohm ±(0,9%+1)<br />

- Capacity 10000µF 1nF ±(1,9%+2)<br />

- Frequency 50kHz 0,01Hz ±(0,1%+2)<br />

- Battery life time Alkali, 300h typical<br />

- Dimensions (HxWxD) 160mm x 96mm x 46mm<br />

- Weight 0,35kg<br />

<strong>Operating</strong> <strong>Manual</strong><br />

810268_810275BAL0400604aE.sxw<br />

Date: 17. Mai 2004<br />

Page: 10 of 12<br />

Fon: +49 70 72 / 91 43 -0<br />

www.schnier-elektrostatik.de<br />

<strong>SCHNIER</strong> <strong>Elektrostatik</strong> <strong>GmbH</strong><br />

Robert-Bosch-Str. 60<br />

72810 Gomaringen


Your partner for high voltage technique ... for sure !<br />

Sturdy Transport case Art.-N°.: 140061<br />

Sturdy transport case with alu-edgings and lockable hinges. With sufficient space for<br />

the measuring lance, the earth stick, FLUKE 110 and accessories.<br />

6.3 Guarantee Any kind of guarantee is abolished once no original<br />

spare parts are being used !<br />

6.4 Our company address Schnier <strong>Elektrostatik</strong> <strong>GmbH</strong><br />

Robert-Bosch-Strraße 60<br />

D 72810 Gomaringen, GERMANY<br />

Fon.: +49 (0) 7072 / 91 43-0<br />

Fax: +49 (0) 7072 /91 43-20<br />

Internet: www.schnier-elektrostatik.de<br />

eMail: mail@schnier-elektrostatik.de<br />

<strong>Operating</strong> <strong>Manual</strong><br />

810268_810275BAL0400604aE.sxw<br />

Date: 17. Mai 2004<br />

Page: 11 of 12<br />

Fon: +49 70 72 / 91 43 -0<br />

www.schnier-elektrostatik.de<br />

<strong>SCHNIER</strong> <strong>Elektrostatik</strong> <strong>GmbH</strong><br />

Robert-Bosch-Str. 60<br />

72810 Gomaringen


Your partner for high voltage technique ... for sure !<br />

<strong>Operating</strong> <strong>Manual</strong><br />

810268_810275BAL0400604aE.sxw<br />

Date: 17. Mai 2004<br />

Schnier <strong>Elektrostatik</strong> <strong>GmbH</strong><br />

Robert-Bosch-Str. 60<br />

D 72810 Gomaringen, GERMANY<br />

Fon.: +49 (0) 7072 9143-0<br />

Fax: +49 (0) 7072 9143-20<br />

Internet: www.schnier-elektrostatik.de<br />

eMail: mail@schnier-elektrostatik.de<br />