MEDIUM VOLTAGE TRANSFORMERS

SUPPLY AND BATTERY CHARGER ENEL DK5600 STANDARDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295

TOROIDAL CURRENT TRANSFORMERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296

TOROIDAL CURRENT TRANSFORMERS CEI-UNEL STANDARDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 298

BRICK TYPE CURRENT TRANSFORMERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299

CURRENT TRANSFORMERS DIN STANDARDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301

VOLTAGE TRANSFORMERS CEI-UNEL STANDARDS, PHASE-PHASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303

VOLTAGE TRANSFORMERS CEI-UNEL STANDARDS, PHASE-GROUND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304

VOLTAGE TRANSFORMERS DIN STANDARDS, PHASE-PHASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 305

VOLTAGE TRANSFORMERS DIN STANDARDS, PHASE-GROUND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 306

VOLTAGE TRANSFORMERS FUSE-HOLDER, PHASE-GROUND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 307

All the magnetic cores and winding of transformers present in this catalogue are made by Revalco, while the resin

insulation is made by a primary italian company that provide also to test and certify the products.

SUPPLY AND BATTERY CHARGER ENEL DK5600 STANDARDS

Fuse 10A

C

OK =Closed contact

NO OK = Closed contact

-

BATTERY

12VDC

+

GENERAL DESCRIPTION

Stabilised supply / Battery charger model 3RAL2410 dedicated to PG protections (General Protections for ENEL DK 5600 standards) is furnished complete with two

external batteries 12VDC-5Ah-20Hr. The scope of this device is to maintain always in charge these batteries that in their turn, assure (in case of power failure from the

net) the power supply of the connected protection relay, for at least 2 hours, or up to the normal restoration of power supply.

3RAL2410 is also furnished with a minimum voltage relay calibrated at 22VDC and rearm at 23VDC linkable with an alarm.

The block Stabilised supply / Battery charger delivers 10A as nominal current at 24VDC for a total nominal power of 240VA. With the scope to avoid inopportune

interventions caused by battery peaks electrical inputs, this device has a 30 seconds delayed time damage signalling (it is recommended to don’t change this value).

- Charge current limitation: 10A

- Rapid protection fuse: 6,3x31(Imax)

- Thermic protection: electronic with reduction of Power

- Discharged battery protection: delivery limitation

- End charge voltage level: adjustable

- Charge current level: predeterminated

- Regular work indication: green led

-

Protection relay

TECHNICAL DATA

CONNECTION DIAGRAM AND DIMENSIONS

BATTERY

12VDC

- Green flashing led: during the predeterminated delayed time (30 sec)

- Limitation/anomaly indication: red led

- Adjustment active element: MOSFET

- Linear adjuster (EMC): no commutation elements

- Galvanic separation: from transformer with thermic protection

- Fixing system: by screws on the aluminium base holes

+

400V

230V

C

Dimensions in mm

363

335

15

6

110

TOTAL HEIGHT = 150mm

10

2,5

14

295


296

S1

S2

TOROIDAL CURRENT TRANSFORMERS

FOR INSULATED CABLES - FOR MEASURE AND PROTECTION TEN SERIES - 0,72 kV

S1

S2

- Nominal primary current from 40 to 6000A, secondary 5A or

1A to specify when ordering

- Frequency: 40 - 60 Hz

- Test voltage: 3 kV for 1 min

- Insulation: class E

- Permanent over current: 1,2 In

- Short circuit thermic current (Iter): up to 40kA for 1 second

- Short circuit dynamic current (Idin): 2,5 Iter for 1 second

- Minimum protection degree: IP55

S1

S2

63

120

TEN70R

145

104,5

60°

60°

ø180

6,5

ø275

6,5

80

R82

R

260

ø70

ø160

S1

S2

60°

S1

ø500

S2

6,5

R

- Safety factor (Fs): < 10 for measurement transformers

- Temperature: working -25°C ÷ +50°C; storage -40°C ÷ +80°C

- Construction following the standards CEI EN60044-1

- Secondaries number: 1 or 2 on request

- Indoor installation

- Toroidal transformers in resin (taped TEN...N on request)

- During the offer it is necessary to specify all the

technical details: primary and secondary, power (VA),

class (example: cl.0,5, 5P10, ecc.)

FOR INSULATED CABLES TEN70 SERIES - 0,72 kV (ENEL DK5600/CEI 0-16 Ed. II)

Phase TEN current transformers established by the ENEL DK 5600 standards, are dedicated to power the General Protection(PG) and their principal function

is to protect, in selective way, the Energy Distributor net in case of damage. TEN70R/N must power, with acceptable errors, the PG protection within the

variable range accepted by the primary current.

- Insulation class: II - Permanent nominal thermic current: 1,2 Ip

- Short circuit nominal thermic current: 12,5kA - Nominal dynamic current: 31,5 kA

- Test voltage: 3kV at 50Hz for 1 min - Working temperature: -20°C……+40C°

- Max temperature on the bars: 70°C - Frequency: 40…..60Hz

- Protection degree: IP 40 - Fixing system: directly on the bar or cable

- Construction following the standards CEI EN60044-1 2000-07; CEI EN60044-1/A1 2001-08; DK5600 Ed. Va 06-2006; CEI 0-16 Ed.II

Other characteristics on request

ø180

IN RESIN

6,5

A kg

300 10

TEN160R

TEN70R 300/5A

TEN70R 300/1A

TEN320R

S1

TEN70R 300/5/5A

TEN70R 300/1/1A

PROTECTION MEASURE AND PROTECTION

60

ø320

125

80

60°

195

ø230

6,5

class 5P30 class 0,5 - 5P30

secondary current 5A secondary current 1A

TEN105R

S2

TEN210R

code VA code VA code VA code VA

TEN70R 300 10 TEN70R 1 300 10 TEN70R 300 5/5 10 TEN70R 300 1/1 10

120

R

104,5

ø105

60°

ø364

6,5

60°

R

ø210

R82

secondary current 5/5A secondary current 1/1A

ø70


TAPED

A kg

300 10

FOR INSULATED CABLES TEN105 SERIES - 0,72 kV (ENEL DK5600/CEI 0-16 Ed. II)

TEN105R/N homopolar current transformers must power, with acceptable

errors, the PG protection within the variable range accepted by the primary

current.

- Insulation class: II

- Permanent nominal thermic current: 800A

- Short circuit nominal thermic current: 12,5kA

- Test voltage: 3kV at 50Hz for 1 min

- Working temperature: -20°C……+40C°

Current [I/In] Ratio error [%] Angle error[°]

0,01 +/- 5 +/- 2

0,05 +/- 1 +/- 2

1 +/- 1 +/- 2

20 +/- 5 +/- 2

REVALCO is present on the ENEL vendor list with the Homopolar transformers (as shown on the following table); CTs that must be

connected to the all models of General Protections (PG) declared in accordance with the standards DK5600 edition Va, 06-2006.

IN RESIN

A kg

100 10

TAPED

A kg

100 10

PROTECTION MEASURE AND PROTECTION

class 5P30 class 0,5 - 5P30

secondary current 5A

- Max temperature on the bars: 70°C

- Frequency: 40…..60Hz

- Protection degree: IP 40

- Fixing system: directly on the bar or cable

- Construction following the Standards CEI EN60044-1, CEI EN60044-1/A1,

DK5600; CEI 0-16 Ed.II

Other characteristics on request

DISPOSITIVI DI PROTEZIONE GENERALE PER CLIENTI MT DI ENEL DISTRIBUZIONE

PROTECTION

class 5P10 class 5P20

secondary current 1A secondary current 1A

code VA code VA

TEN105R1100A 1 1 TEN105R1100A 2

PROTECTION

class 5P10 class 5P20

secondary current 1A secondary current 1A

S1

code VA code VA

TEN105N1100A 1 1 TEN105N1100A 2

S2

60

129,5

50

ø220

ø105

ø230

1 Agosto 2008

Ed.25

TA/TAT VERIFICATI ASSOCIABILI A TUTTE LE PROTEZIONI GENERALI DICHIARATE CONFORMI DK5600 ED. V, 06-2006 (cfr. DK5600 §6.2.2 soluzione a)

COSTRUTTORE MODELLO RAPPORTO PRESTAZIONE (VA) UTILIZZO DATA RAPPORTO DI PROVA

REVALCO

TEN105R

100/

1

2

TAT

14/

02/

2007

REVALCO

TEN105N

100/

1

2

TAT

14/

02/

2007

REVALCO

TEN105RD

100/1

0,5

TAT

16/07/2008

ø160

ø70

code VA code VA code VA

TEN70N 300 10

secondary current 5/5A secondary current 1/1A

TEN70N 300 5/5 10 TEN70N 300 1/1 10

100

ø105

297


298

CURRENT TRANSFORMERS CEI-UNEL STANDARDS

- Dimensions according to CEI-UNEL 21009 std.

- Manufactured and tested acc. to IEC 60044-1

- Standard burden: measure = cl 0,5 / 20VA

protection = cl 5P10 / 10VA

- Rated Insulation level up to 36 kV

- Frequency 50 or 60 Hz

- Rated primary current (Ipn):

- Single primary current from 5 to 2500 A

- Double primary current: Up to 2x300 A change on primary winding

Up to 2x1250 A change on secondary winding

- Rated secondary current (Isn) 5 A

- Short-time current (Ith) up to 40 kA x 1s

- Rated dynamic current (Idyn) 2.5 x Ith

- Number of secondary 1 or 2

=

=

M12

P1

P1

P1

C1

C1

120

C2 C2

A B

P2

P2

P2

= 50 = 90

Ø14

40

GENERAL DESCRIPTION

PRIMARY TERMINALS

32 10

60

5-600 A 800-1200 A

1500-2500 A

≤ 2x300 A DOUBLE PRIMARY CURRENT

≤ 2x1250 A

LOW RATIO

HIGH RATIO

Ø14

MINIMUM ASSEMBLY DISTANCES

RAA111 RAA121 RAA131 RAA141

Ip Max 600A

Max. N° sec. 1

Kg. ~ 14

Ip Max 600A

Max. N° sec. 2

Kg. ~ 16

Dimensions [mm]

Ip Max 1200A

Max. N° sec. 2

Kg. ~ 23

A B C D E F

RAA111 250 180 200 145 105 28

RAA121 250 180 200 175 105 28

RAA131 300 190 220 190 130 50

RAA141 300 190 240 190 130 50

- Safety factor ≤ 5 or ≤ 10

- Indoor installation

ON REQUEST

- Third secondary

- Rated secondary current 1A

- Sealable terminal cover

- Capacitive tap

- Other characteristics

- During the offer it is necessary to specify all technical details

ORDER EXAMPLE

RAA111 300- 300A 5A

RAA121 300A 5-5A

RAA141 2k5 5-5-5A

Ip Max 2500A

Max. N° sec. 3

Kg. ~ 25

10-15

20

40

80

40

ø18

1s1 1s2 2s1 2s2

Sec 1 Sec 2

1s1 1s3 2s1 2s3

Sec 1 Sec 2

[mm] 12 kV 24 kV 36 kV

A 120 220 320

B 120 220 320

ACCORDING TO IEC/CEI EN 60071-1

Ø14

M12

P1

A

C1

160

220

C

155

C2

E

P2

F

6

5

155

Ø11

20

M6

300

D

B

15-20

12 kV

1s1 1s2 2s1 2s2

Sec 1 Sec 2

240

265 Max


RAB111 RAB121 RAB131 RAB161

Ip Max 600A

Max. N° sec. 1

Kg. ~ 16

Dimensions [mm]

A B C D E F

RAB111 300 200 200 150 130 17.5

RAB121 300 200 200 175 130 17.5

RAB131 300 200 220 200 130 17.5

RAB161 300 200 240 200 130 17.5

RAC121

Ip Max 600A

Max. N° sec. 2

Kg. ~ 18

Ip Max 2500A

Max. N° sec. 3

Kg. ~ 30

Dimensions [mm]

Ip Max 1000A

Max. N° sec. 2

Kg. ~ 25

P1

P1

Ip Max 2500A

Max. N° sec. 3

Kg. ~ 28

A B C D E F

330 250 240 230 165 17.5

BRICK TYPE CURRENT TRANSFORMERS

- Compact type suitable for METAL - CLAD switchboards

- Manufactured and tested acc. to IEC 60044-1

- Standard burden: measure = cl 0,5 / 20VA

protection = cl 5P10 / 10VA

- Rated Insulation level up to 24 kV

- Frequency 50 or 60 Hz

- Rated primary current (Ipn)

- Single primary current from 5 to 1250 A

- Double primary current: Up to 2 x 300 A change on prim. winding

Up to 2 x 600 A change on sec. winding

- Rated secondary current (Isn) 5 A

- Short-time current (Ith) up to 40 kA x 1s

- Rated dynamic current (Idyn) 2.5 x Ith

- Number of secondary 1 or 2

=

=

M12

P1

PRIMARY TERMINALS

120

P2

= 32 = 65

5-1250 A

40

Ø14

220

C

A

E

6

20

5

GENERAL DESCRIPTION

M6

C2

C2

D

B

≤ 2x300 A

C1

C1

370

395 Max

P2 P2

Ø14

M12

M12

- Safety factor ≤ 5 or ≤ 10

- Indoor installation

ON REQUEST

- Third secondary

- Rated secondary current 1A

- Sealable terminal cover

- Capacitive tap

- Other characteristics

- During the offer it is necessary to specify all technical details

ORDER EXAMPLE

RABM11 1k25 5A

RABM22-A 1k25 5-5A

RABM11-B 1k25 5-5-5A

P1

A

C1

220

C

225

C2

P1

E

P2

300

C1

C2

F

6

5

P2

175

20

Ø11

DOUBLE PRIMARY CURRENT

LOW RATIO

HIGH RATIO

F

M6

225

Ø11

1s1 1s2 2s1 2s2

Sec 1 Sec 2

1s1 1s3 2s1 2s3

D

B

160

≤ 2x600 A

160

Sec 1 Sec 2

24 kV

300

340

410

325 Max

36 kV

299


300

A

B

MINIMUM ASSEMBLY DISTANCES

[mm] 24 kV

A 220

B 220

ACCORDING TO IEC/CEI EN 60071-1

WITH METALLIC SUPPORTS 24 kV

RABM11

Ip Max 1250A

Max. N° sec. 3

Kg. ~ 18

Dimensions [mm]

A B

RABM11 148 120

RABM22 198 160

RABM22

Ip Max 1250A

Max. N° sec. 3

Kg. ~ 25

M12

32

P1

254

320

120 32

300

C1

C2

160

P2

5

B

Ø11

10

M6

A

235

1s1 1s2 2s1 2s2

Sec 1 Sec 2

WITHOUT METALLIC SUPPORTS - SECONDARY TERMINALS EXECUTION “A” 24 kV

RABM11-A

Ip Max 1250A

Max. N° sec. 3

Kg. ~ 18

Dimensions [mm]

A

RABM11-A 148

RABM22-A 198

RABM22-A

Ip Max 1250A

Max. N° sec. 3

Kg. ~ 25

M8

M6

A

235

260 Max

M12

32

P1

254

C1

C2

127

120 32

WITHOUT METALLIC SUPPORTS - SECONDARY TERMINALS EXECUTION “B” 24 kV

RABM11-B

Ip Max 1250A

Max. N° sec. 3

Kg. ~ 18

Dimensions [mm]

A

RABM11-B 148

RABM22-B 198

RABM22-B

Ip Max 1250A

Max. N° sec. 3

Kg. ~ 25

M8

150

52

254

198

150

120

127

52

120

M12

A

88

32

P1

P2

C1

C2

247

260 Max

120 32

272 Max

P2


- Dimensions according to DIN 42 600 TEIL 8 std.

- Manufactured and tested acc. to IEC 60044-1

- Standard burden: measure = cl 0,5 / 20VA

protection = cl 5P10 / 10VA

- Rated Insulation level up to 24 kV

- Frequency 50 or 60 Hz

- Rated primary current (Ipn)

- Single primary current from 5 to 2500 A

- Double primary current: Up to 2 x 300 A change on prim. winding

Up to 2 x 1250 A change on sec. winding

- Rated secondary current (Isn) 5 A

- Short-time current (Ith) up to 40 kA x 1s

- Rated dynamic current (Idyn) 2.5 x Ith

55

M12

=

=

Ka P1

Ka P1

Ka P1

65

Kb C1

Kb C1

A

120

B

Lb

P2

= 32 =

40

12 kV 24kV

La C2

La C2

Lb P2

Lb P2

5-600 A

Ka P1

Ka

5-1500 A

P1

PRIMARY TERMINALS

DOUBLE PRIMARY CURRENT

Kb C1

La C2

Kb

La

C1

C2

Lb

Lb

P2

P2

5-2500 A

LOW RATIO

HIGH RATIO

MINIMUM ASSEMBLY DISTANCES

40 =

=

M12

= 32 =

Ka P1

M5

M5

120

[mm] 12 kV 24 kV

A 120 220

B 120 220

Lb P2

Sec 1

ACCORDING TO IEC/CEI EN 60071-1

70

1s1 1s2 2s1 2s2

Sec 1 Sec 2

800-2500 A

1s1 1s3 2s1 2s3

SECONDARY TERMINALS DIN STANDARDS 12 kV

PG16

32

CURRENT TRANSFORMERS DIN STANDARDS

177.5

RAAD11

Standard execution

Ip Max 2500A

Max. N° sec. 3

Kg. ~ 18

250

350

150

148

GENERAL DESCRIPTION

5

220

245 Max

- Number of secondary 1 or 2

- Security factor ≤ 5 or ≤ 10

- Indoor installation

- Secondary terminal board accordint to DIN

ON REQUEST

- Third secondary, Rated secondary current 1A, Capacitive tap, Execution

with wings, Standard sec. terminal board

- Other characteristics

- During the offer it is necessary to specify all technical details

ORDER EXAMPLE

RAAD11 2k5 5A

RAAD11-N 2k5 5-5A

RABD11-AN 2k5 5-5-5A

105

M12 32 120 32

Ka P1

KbC1

La C2

270

Lb P2

RAAD11-A

Wings execution

Ip Max 2500A

Max. N° sec. 3

Kg. ~ 18

125

Ø14

15

75

139

60

105

Sec 2

2

40

70

34

32

301


55

STANDARD SECONDARY TERMINAL BOARD 12 kV

302

RAAD11-N

Standard execution

Ip Max 2500A

Max. N° sec. 3

Kg. ~ 18

M12

105

32

P1

RAAD11-AN

Wings execution

Ip Max 2500A

Max. N° sec. 3

Kg. ~ 18

C1

120 32

SECONDARY TERMINALS DIN STANDARDS 24 kV

PG16

32

187.5

365

250

300

270

150

M6

RABD11

Standard execution

Ip Max 2500A

Max. N° sec. 3

Kg. ~ 18

148

5

220

STANDARD SECONDARY TERMINAL BOARD 24 kV

270

310

155

178

RABD11-N

Standard execution

Ip Max 2500A

Max. N° sec. 3

Kg. ~ 25

155

M6

5

178

280

305 Max

5

280

305 Max

245 Max

105

M12

32

Ka P1

M12

105

120 32

Kb C1

La C2

Lb P2

C2

270

P2

15

RABD11-A

Wings execution

Ip Max 2500A

Max. N° sec. 3

Kg. ~ 25

150

280 15

32

P1

Ø14

75

RABD11-AN

Wings execution

Ip Max 2500A

Max. N° sec. 3

Kg. ~ 25

120 32

C1

C2

P2

150

Ø14

280 15

125 Ø14

60

105

139

2

40

34

32


VOLTAGE TRANSFORMERS CEI-UNEL STANDARDS, PHASE-PHASE

- Dimensions according to CEI-UNEL 21008 standards

- Manufactured and tested acc. to IEC 60044-2

- Standard burden: measure = cl 0,5 / 50VA

- Rated Insulation level up to 36 kV

- Frequency 50 or 60 Hz

- Rated voltage factor 1,2 continuous

- Number of secondary 1

- Rated secondary voltage 100 V

- Indoor installation

PRIMARY TERMINALS DOUBLE PRIMARY CURRENT

A B M10

RVCA11

Upn (kV) ≤ 12

Max. N° sec. 2

Kg. ~ 20

H

M10

A

L

A

B

I

E

N

M

Ø11

C

M6

RVCB11

Upn (kV) ≤ 24

Max. N° sec. 2

Kg. ~ 30

D

F

B

GENERAL DESCRIPTION

ON REQUEST

- Second secondary

- Double primary ratio

- Sealable terminal cover

- Rated secondary voltage 110 V

- Other characteristics

- During the offer it is necessary to specify all technical details

ORDER EXAMPLE

RVCA11 10/10 (10000/100V)

RVCB11 20/10 (20000/100V)

1a1 1b

2a1 2b

1a2

1b

2a2 2b

Sec 1 Sec 2 Sec 1 Sec 2

5

a1 b1 a2 b2

Sec 1 Sec 2

G

LOW RATIO HIGH RATIO

Dimensions [mm]

12 kV - 24 kV - 36 kV

RVCC11

Upn (kV) ≤ 36

Max. N° sec. 2

Kg. ~ 50

A B C D E F G H I L M N

RVCA11 305 180 240 195 145 155 225 143 137,5 155 155 67,5

RVCB11 340 200 295 260 160 210 300 175 150 225 175 47,5

RVCC11 330 260 395 380 165 320 390 300 225 15

M10

260

A

L

E

N

M

Ø11

C

D

F

A B

M6

B

a1 b1 a2 b2

Sec 1 Sec 2

5

G

303


VOLTAGE TRANSFORMERS CEI-UNEL STANDARDS, PHASE-GROUND

- Dimensions according to CEI-UNEL 21007 std.

- Manufactured and tested acc. to IEC 60044-2

- Rated Insulation level up to 36 kV

- Frequency 50 or 60 Hz

- Rated voltage factor 1,2 continuous and 1,9/8h

- Number of secondaries 2

- Rated secondary voltage: Measuring or protective winding: 100: 3 V

Residual voltage winding: 100:3 V

- Indoor installation

M10

F

A M10

G

E

A

H L

A

I

Ø11

M8

M6

a

D

N

B

n

a1 n

da1 dn

a2

n

da2 dn

N

5

C

da dn

Sec 1 Sec 2

GENERAL DESCRIPTION

ON REQUEST

- Third secondary

- Double primary ratio

- Sealable terminal cover

- Rated secondary voltage: 110: 3 V - 110:3 V

- Other characteristics

- During the offer it is necessary to specify all technical details

ORDER EXAMPLE

RVFB11 20R 1003 100R (20KV: 3 / 100:3 / 100: 3

RVFB11 20R 15R 103 10R (20KV: 3 - 15KV: 3 / 100:3 / 100: 3

PRIMARY TERMINALS DOUBLE PRIMARY CURRENT

Sec 1 Sec 2 Sec 1 Sec 2

LOW RATIO HIGH RATIO

A B MINIMUM ASSEMBLY DISTANCES

RVFA11

Upn (kV) ≤ 12: 3

Max. N° sec. 3

Kg. ~ 22

RVFB11

Upn (kV) ≤ 24: 3

Max. N° sec. 3

Kg. ~ 30

Dimensions - Dimensions - Dimensions [mm]

[mm] 12 kV 24 kV 36 kV

A 120 220 320

B 120 220 320

ACCORDING TO IEC/CEI EN 60071-1

A B C D E F G H I L

RVFA11 305 180 240 180 145 150 130 155 155 67,5

RVFB11 340 200 300 200 160 170 140 225 175 47,5

RVFC11

304

400 250 390 240 155 175 155 300 225 15

M10

F

A

A

G

12 kV - 24 kV - 36 kV

M8

M6

E B

H L

I

Ø11

a

RVFC11

Upn (kV) ≤ 36

Max. N° sec. 2

Kg. ~ 50

n

D

N

N

da dn

Sec 1 Sec 2

5

C


M10

110

VOLTAGE TRANSFORMERS DIN STANDARDS

- Dimensions according to DIN42 600 TEIL 9 standards

- Manufactured and tested acc. to IEC 60044-2

- Rated Insulation level up to 24 kV

- Frequency 50 or 60 Hz

- Rated voltage factor 1,2 continuous

- Number of secondary 1

- Rated secondary voltage 100 V

- Indoor installation

- Secondary terminal board according to DIN

A

U

100

B

V

GENERAL DESCRIPTION

M5

1a1 1b 2a1 2b

ON REQUEST

- Second secondary

- Double primary ratio

- Standard sec. terminal board

- Rated secondary voltage 110 V

- Other characteristics

- During the offer it is necessary to specify all technical details

ORDER EXAMPLE

RVCAD1 10/10 (10000/100V)

RVCBD1 20/10 (20000/100V)

PRIMARY TERMINALS DOUBLE PRIMARY CURRENT

RVCAD1

Upn (kV) ≤ 12

Max. N° sec. 2

Kg. ~ 22

RVCBD1

Upn (kV) ≤ 24

Max. N° sec. 2

Kg. ~ 30

1a2 1b 2a2 2b

Sec 1 Sec 2

Sec 1 Sec 2

LOW RATIO HIGH RATIO

SECONDARY TERMINALS DIN STANDARDS 12 kV

55

PG16

32

250

100

177,5 150

STANDARD SECONDARY TERMINAL BOARD 12 kV

105

350

U

A

V

B

M5

110

148

Ø14 M10

105

A

270

270

165

365

280

B

155

Ø14 M10

125

150

15

15

75

M6

60

139

130

178

5

2

40

34

5

220

280

32

305


VOLTAGE TRANSFORMERS DIN STANDARDS, PHASE-GROUND

- Dimensions according to DIN42 600 TEIL 9 standards

- Manufactured and tested acc. to IEC 60044-2

- Rated Insulation level up to 24 kV

- Frequency 50 or 60 Hz

- Rated voltage factor 1,2 continuous and 1,9/8h

- Number of secondary 2

- Rated secondary voltage: Measuring or protective winding: 100: 3 V

Residual voltage winding: 100:3 V

- Indoor installation

- Secondary terminal board according to DIN

306

A

U

M10

GENERAL DESCRIPTION

ON REQUEST

- Second secondary

- Double primary ratio

- Standard secondary terminal board

- Rated secondary voltage: 110: 3 V - 110:3 V

- Other characteristics

- During the offer it is necessary to specify all technical details

ORDER EXAMPLE

RVFAD1 10R 1003 100R (10kV: 3 / 100:3 / 100: 3

RVFBD1 20R 15R 103 10R (20kV: 3 - 15kV: 3 / 100:3 / 100: 3

PRIMARY TERMINALS DOUBLE PRIMARY CURRENT

A B

MINIMUM ASSEMBLY DISTANCES

M5

a1 n

Sec 1

Sec 1

LOW RATIO HIGH RATIO

[mm] 12 kV 24 kV

A 120 220

B 120 220

ACCORDING TO IEC/CEI EN 60071-1

SECONDARY TERMINALS DIN STANDARDS 12 kV - 24 kV

RVFAD1

Upn (kV) ≤ 12: 3

Max. N° sec. 2

Kg. ~ 22

55

PG16

32

105

177,5 150

U

A

Ø14 M10

105

STANDARD SECONDARY TERMINAL BOARD 12 kV - 24 kV

RVFBD1

Upn (kV) ≤ 24: 3

Max. N° sec. 2

Kg. ~ 30

270

365

155

M6

350

250

270

N

178

5

280

125

15

M5

a2

75

n

A

148

60

139

280

2

40

5

34

Ø14 M10

220

32

150

15


- Manufactured and tested acc. to IEC 60044-2

- Rated Insulation level up to 36 kV

- Frequency 50 or 60 Hz

- Rated voltage factor 1,2 continuous and 1,9/8h

- Number of secondary 2

- Rated secondary voltage: Measuring or protective winding: 100: 3 V

Residual voltage winding: 100:3 V

- Indoor installation

I

VOLTAGE TRANSFORMERS FUSE-HOLDER, PHASE-GROUND

A M10

GENERAL DESCRIPTION

A B

MINIMUM ASSEMBLY DISTANCES

ON REQUEST

- Third secondary

- Double primary ratio

- Sealable terminal cover

- Rated secondary voltage: 110: 3 V - 110:3 V

- Other characteristics

- During the offer it is necessary to specify all technical details

ORDER EXAMPLE

RVFTS1 20R 1003 100R (20kV: 3 / 100:3 / 100: 3

RVFCS1 20R 15R 103 10R (20kV: 3 - 15kV: 3 / 100:3 / 100: 3

PRIMARY TERMINALS DOUBLE PRIMARY CURRENT

M6

M8

N

H

L

A

M

D

B

a1 n

da1 dn

a2

n

da2 dn

5

G

C

Sec 1 Sec 2 Sec 1 Sec 2

LOW RATIO HIGH RATIO

[mm] 12 kV 24 kV 36 kV

A 120 220 320

B 120 220 320

ACCORDING TO IEC/CEI EN 60071-1

STANDARD SECONDARY TERMINAL BOARD 12 kV - 24 kV - 36 kV

F

RVFTS1

Upn (kV) ≤ 17,5: 3

Max. N° sec. 3

Kg. ~ 20

E

N

Ø9

M6

a

n

N

da dn

Sec 1 Sec 2

RVFBS1

Upn (kV) ≤ 24: 3

Max. N° sec. 3

Kg. ~ 28

Dimensions [mm]

A B C D E F G H I L M N

RVFTS1 225 150 303 160 112,5 405 265 275 76 195 130 15

RVFBS1 225 150 338 180 112,5 517 300 309 76 195 130 15

RVFCS1 400 250 680 240 163 240 106 300 225 15

M10

A

L

F

I

A

E

N

M

Ø11

M8

M6

a

RVFCS1

Upn (kV) ≤ 36: 3

Max. N° sec. 3

Kg. ~ 40

n

N

D

B

N

5

da dn

Sec 1 Sec 2

C