30.06.2013 Views

Oriel High Power Spectral Calibration Lamps

Oriel High Power Spectral Calibration Lamps

Oriel High Power Spectral Calibration Lamps

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

TECHNICAL<br />

REFERENCE<br />

CALIBRATION SOURCES<br />

DEUTERIUM SOURCES<br />

ARC SOURCES<br />

INCANDESCENT SOURCES<br />

MONOCHROMATOR AND<br />

FIBER ILLUMINATORS<br />

SOLAR SIMULATORS<br />

PHOTOLITHOGRAPHY<br />

INSTRUMENTS<br />

ACCESSORIES FOR<br />

ORIEL LIGHT SOURCES<br />

78<br />

Light Sources<br />

<strong>Oriel</strong> <strong>High</strong> <strong>Power</strong> <strong>Spectral</strong> <strong>Calibration</strong> <strong>Lamps</strong><br />

65130 and 65010 <strong>High</strong> <strong>Power</strong> <strong>Spectral</strong> Line <strong>Lamps</strong><br />

Choose these sources if you require very intense, discrete spectral<br />

lines. These lamps are approximately 2X more intense than<br />

comparable pencil calibration lamps (see page 75), although the<br />

spectral intensity distribution is very different. The lamps are<br />

housed in the 65160 Lamp Housing, which has an integrated filter<br />

holder to hold 1.0 inch (25.4 mm) diameter interference filters,<br />

and powered by the 65150 Regulated AC <strong>Power</strong> Supply. Because<br />

the power supply operates in regulated AC mode, there are rapid<br />

variations in output on an ms time scale. However, the average<br />

output over many seconds is very stable.<br />

Z Bracket Lowers Optical Axis Height<br />

The 66275 Z Bracket lets you rod mount the 65160 Lamp Mount at<br />

a low optical axis height to match our monochromator inputs. The<br />

lowest centerline height with this mount is 2.8 inches (71 mm).<br />

See page 244 for more details on the 66275.<br />

65010 Cs<br />

65020 He<br />

65130 Hg<br />

65060 HgCd<br />

65080 Na<br />

65090 Ne<br />

65110 Tl<br />

65120 Zn<br />

65130 Hg<br />

250 300 350 400 450 500 550 600 650 nm<br />

250<br />

237.8<br />

240.0<br />

250<br />

253.7<br />

253.6<br />

300<br />

Fig. 1 Output spectra of <strong>High</strong> <strong>Power</strong> <strong>Spectral</strong> <strong>Calibration</strong> <strong>Lamps</strong>.<br />

265.4<br />

275.3<br />

• Sources of intense, discrete UV, VIS and NIR spectral lines<br />

• <strong>High</strong>ly stable long-term output<br />

• Low cost rod mounted housing supports lamps<br />

• Easily interchangeable lamps<br />

350<br />

289.4<br />

296.8<br />

300<br />

WAVELENGTH (nm)<br />

Safety Considerations<br />

65160 Lamp Housing on 66275 Z Bracket.<br />

SPECTRAL LINES BELOW 400 nm SPECTRAL LINES ABOVE 400 nm<br />

400<br />

350<br />

Phone: 1-800-222-6440 • Fax: 1-949-253-1680<br />

Although these are low wattage sources, they still emit<br />

hazardous UV radiation. Be sure to wear protective eyewear and<br />

gloves (see page 246 for UV safety equipment).<br />

312.6<br />

334.1<br />

365.0/6.3<br />

390.6<br />

450 500 550 600 650 nm<br />

400<br />

nm


Specifications<br />

<strong>Power</strong> Supply<br />

Starting Voltage 600 V peak to peak for ca. 350 ms<br />

Operating Voltage 10 - 60 V, lamp dependent<br />

Operating Current 0,6 - 1 A, lamp dependent<br />

Input 115 V / 2.4 A or 230 V / 1.2 A<br />

Weight 18.2<br />

System<br />

Line Regulation (