Operation Diagnostic System<br />

Application<br />

Technology:<br />

Load:<br />

Application:<br />

Certificate of Quality<br />

Varistors Standard<br />

Elect.<br />

Magn. Interfer.<br />

Protec. Standard acc.<br />

ISO 9001:2008<br />

IEC 61643-1; UL 1449<br />

IEC 60939-2<br />

IEC 61643-1 C lass I+II<br />

+III<br />

Sur SurGe Multi-Stage <strong>Surge</strong> Protection; Eight (8) Stages Series Protector<br />

Specification: Cascade bi-directional EMI-RFI filtering of phase (L) and neutral (N) wire<br />

Up to 25A single phase; up to 3kW load for 120VAC; up to 5kW load for 230VAC<br />

Options: Indication for bed grounding<br />

Installation: Plug-in installation, schuko plug, terminal block or according requirements<br />

Product Standard:<br />

Normal:<br />

Continuous yellow<br />

and green<br />

Fault:<br />

Continuous green<br />

Fault:<br />

Blinking red<br />

Fault:<br />

Continuous red<br />

Single phase Models - ACDC <strong>Surge</strong> Protectors Orange Series<br />

IEC61643-1 Class I+II+III; IEC60939-2<br />

Type<br />

Power Supply<br />

Type - PS 11-M<br />

Type - PS 137-M<br />

Type - PS 146-M<br />

Red Yellow Green<br />

U(V)<br />

Order Code<br />

500.215<br />

500.216<br />

500.217<br />

Operation Diagnostic System<br />

Random Noice<br />

5 10 15 20<br />

MULTI-STAGE SURGE PROTECTION<br />

Applications: Features:<br />

Computers<br />

Servers<br />

Telecommunication<br />

Medical equipment<br />

Sensitive electronic<br />

Solars<br />

Industrial grade<br />

Total <strong>Surge</strong> Cur.<br />

105kA(8/20μs) or<br />

15kA(10/350μs)<br />

125kA (8/20μs) or<br />

18kA (10/350μs)<br />

150kA (8/20μs) or<br />

22kA (10/350μs)<br />

Dimension<br />

(WxDxHmm)<br />

220x50x45<br />

220x50x45<br />

220x50x45<br />

Led Indication for correct stage no. 2,4 and 6. The stages no. 1,3 and 7 (high<br />

garde bi-directional filtering) are always in function along with ultimate (5-th)<br />

protection stage.<br />

Led Indication for correct stage no. 4,6 and un correct no 2. The stages no. 1,3<br />

and 7 (bi-directional filtering) are always in function along with ultimate (5-th)<br />

protection stage.<br />

Led Indication for fault installation or bed grounding (Low impedance equipotential<br />

ground is not provided)<br />

Only stages 1,3 and 7 are still in function along with ultimate (5-th) protection<br />

stage.<br />

Voltage Spike<br />

ACDC SURGE<br />

PROTECTOR<br />

Waveform Tracking Filter<br />

Safe Power Supply<br />

Weight<br />

(kg)<br />

1,6<br />

Integrate Multi - Stage Protection System<br />

Eight Protection Stages<br />

Bi-directional Wave Filtering<br />

Expel Ground Contamination<br />

Thermal Circuit Protection<br />

High Reliability<br />

Excellent Response Time < 1ns<br />

acdc-dcac@acdc-dcac.eu ACDC DCAC Dane Krapcev no.2/1, 1000-Skopje, Macedonia Phone: 389 2 3216 988; Fax: 389 2 3216 993<br />

t (ms)<br />

Home<br />

Telekom<br />

1,6<br />

1,6<br />

Mobile Base Station<br />

Industry Solar Wind energy