24.07.2013 Views

ACDC Protect Mobile Base Stations - ACDC Surge Protectors (http://shop.acdc-dcac.eu/)

ACDC DCAC Company as manufacturer of Multi-Stage Surge Protectors has opened online web store that is available for worldwide buyers ( http://shop.acdc-dcac.eu ). Necessity about this step was requested from many of our customers which have required our sophisticated multi-stage surge protection for their electrical devices. Our online store provides quick and easy order and fast post-delivery to your door.

ACDC DCAC Company as manufacturer of Multi-Stage Surge Protectors has opened online web store that is available for worldwide buyers ( http://shop.acdc-dcac.eu ). Necessity about this step was requested from many of our customers which have required our sophisticated multi-stage surge protection for their electrical devices. Our online store provides quick and easy order and fast post-delivery to your door.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

New<br />

Innovative<br />

<strong>Surge</strong><br />

<strong>Protect</strong>ion<br />

Technology<br />

<strong>Surge</strong> <strong>Protect</strong>ors Manufacture<br />

Multi-Stage <strong>Surge</strong> <strong>Protect</strong>ion<br />

Skopje, Macedonia<br />

<strong>ACDC</strong> DCAC <strong>Protect</strong> <strong>Mobile</strong> <strong>Base</strong> <strong>Stations</strong><br />

...We Care for Safety of Your Electronic Devices<br />

Telecommunication systems, electronic equipments and especially<br />

<strong>Mobile</strong> <strong>Base</strong> Station, are often installed in environments exposed to<br />

electromagnetic disturbances and atmospheric discharges.<br />

Sophisticate transmitting and receiving systems in mobile phone<br />

networks are primarily installed at open spaces and exposed to<br />

high-frequency oscillations and spikes in power network supply,<br />

induced transients and atmospheric discharges.<br />

A complex concept for protection of <strong>Mobile</strong> <strong>Base</strong> <strong>Stations</strong> includes<br />

providing good quality of grounding, protection of the primary<br />

atmospheric discharges and protection of surges induced in the<br />

power grid.<br />

Years of experience in the protection of mobile base stations of<br />

leading national and international providers has shown that only a<br />

Multi-stage surge protection from CLASS I+II+III can fulfill the<br />

requirements for safe and no-compromise protection of all types<br />

and strengths of surges induced in power grid.<br />

The implementation of multi-stage surge protectors for protection<br />

of <strong>Mobile</strong> base stations are the most advantages and reliable<br />

“today-known” protection system.<br />

<strong>ACDC</strong> <strong>Surge</strong> <strong>Protect</strong>ors are multi-stage surge protectors consists<br />

of 8 (eight) protection stages which provides no-compromise and<br />

effective protection from all types and voltage shapes of surges<br />

(transients) in power network supply. The protectors is from CLASS<br />

I+II+III according IEC61643-1 and also full fill standard requirements<br />

for protection of electromagnetic (radio) interference<br />

suppression IEC60939-2.<br />

The <strong>ACDC</strong> <strong>Surge</strong> <strong>Protect</strong>or is not just “spike protector” as the most<br />

of surge protectors does. Consist part of surge protector is cascade<br />

bi-directional EMI/RFI filtering which allows consist tracking<br />

the sine waveform and filtering the power network supply, which is<br />

the most important part in the protection of sophisticated<br />

telecommunication equipments and <strong>Mobile</strong> base stations.<br />

-


MULTI-STAGE SURGE PROTECTION<br />

<strong>ACDC</strong> SURGE PROTECTOR<br />

EIGHT (8) STAGES SERIES PROTECTOR 1/1 & 3/3<br />

HARD WIRE INSTALLATION<br />

CLASS LPZ LPZ IP<br />

I+II+III 0 1 2 3 20<br />

Multi-Stage <strong>Surge</strong> <strong>Protect</strong>ion at the<br />

entry of the power network supply<br />

U(V)<br />

Uef<br />

telecom<br />

cellular<br />

Voltage Spike<br />

Diesel Engine<br />

Type-PI (780; 7100, 7125; 7200) Green Series<br />

<strong>Mobile</strong> <strong>Base</strong> <strong>Stations</strong><br />

MCB<br />

SurGe<br />

MULTI-STAGE SURGE PROTECTION FOR MOBILE BASE STATION<br />

Single Phase & Three Phase CLASS I+II+III<br />

Load Rating: 230VAC /400VAC & 100A<br />

Response Time: < 1ns<br />

Multi-Stage <strong>Surge</strong> <strong>Protect</strong>ion<br />

for light on the top of tower<br />

Radio Link<br />

<strong>ACDC</strong> DCAC Dane Krapcev no.2/1, 1000-Skopje, Macedonia Phone: 389 2 3216 988; Fax: 389 2 3216 993<br />

Light<br />

SurGe <strong>Protect</strong>ion<br />

www.<strong>acdc</strong>-<strong>dcac</strong>.<strong>eu</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!