Default settings<br />

<strong>System</strong> <strong>Manual</strong> – DOP11A <strong>Operator</strong> <strong>Terminal</strong>s<br />

Programming<br />

Communication with MOVIDRIVE® and MOVITRAC® 07<br />

Figure 29: Default settings<br />

Port RS-232C or RS-422<br />

Baud rate 9600<br />

Data bits 8<br />

Stop bits 1<br />

Parity Even<br />

Settings The RS-485 inverter address is defined under Settings.<br />

You can enter values between 0-99, 254 and 255.<br />

10772AXX<br />

Parameter Description<br />

Default station A communication is established with the inverter address entered under Default station<br />

during startup of the operator terminal after power on.<br />

This inverter address will always be used if no other RS-485 address is specified when<br />

defining the communication objects.<br />

Address Use / description<br />

0-99 Individual inverter address<br />

254 Peer-to-peer communicaton<br />

This address must not be used when several inverters are connected with the operator<br />

terminal via RS-485.<br />

255 Broadcast address<br />

All inverters connected to the RS-485 bus receive data but do not return a response to<br />

the operator terminal.<br />