<strong>CIDCO</strong> OF MAHARASHTRA LTD<br />

C.A.No.01/<strong>CIDCO</strong>/SE(KHR)/EE(KHR-I)/2010–11 Pg. No. 566<br />

2. At all construction joints in the beams, slabs and columns etc.<br />

1.15.15 Measurements:<br />

laitance and any other loose concrete shall be chipped off<br />

immediately after striking the formwork. The chipped surface<br />

shall then be thoroughly cleaned with a jet of water.<br />

1. Where formwork is paid separately, measurements shall be of<br />

the area of finally exposed surface requiring shuttering<br />

including curves, angles, splays, metres, bevels, etc. for which<br />

no special rate shall be allowed. The rates shall be inclusive of<br />

all work connected with provision of formwork, its erection<br />

and removal and treatment of the concrete surface<br />

immediately after removal of the formwork.<br />

2. No extra payment shall be made for holes to be made in<br />

formwork for inserting electrical conduits, hooks for fans, for<br />

plumbing work.<br />

3. Where boxes or pockets are required to be formed in the<br />

concrete, they will be paid for separately at the Contract Rates,<br />

but in measuring the area of concrete surfaces shuttered, no<br />

deduction will be made for openings upto 0.4m 2 . For voids<br />

larger than 0.4m 2 the surface of formwork forming the voids<br />

shall be paid at rates of formwork set out in the Schedule and<br />

the area of voids deducted from the face area of shuttering.<br />

4. No deductions shall be made from formwork of main beams<br />

where the secondary beams intersects it. Formwork to<br />

secondary beams shall be measured upto sides of the main<br />

beams. No deduction shall be made from the formwork to<br />

stanchion or column casings at intersections of beam.