<strong>CIDCO</strong> OF MAHARASHTRA LTD<br />

C.A.No.01/<strong>CIDCO</strong>/SE(KHR)/EE(KHR-I)/2010–11 Pg. No. 316<br />

Information to be included in the delivery ticket to the purchaser<br />

shall be as per Annexure “G” of IS: 4926-2003.<br />

Material testing reports shall invariably be submitting by the<br />

producer as per Annexure “B” of IS: 4926-2003<br />

Time in transport i.e. the time of loading/mixing water to the time of<br />

discharge from the truck mixer shall not be more than 2 hrs.<br />

16.0 Providing and constructing B.B. Masonry chamber of 90 x 60 cm.<br />

internal size and depth up to 1.2m. with precast R.C.C. slab cover<br />

with 15 cm. thick 1:3:6 proportion P.C.C. bedding, including<br />

excavation, B.B. Masonry in C.M. 1:4 proportion precast R.C.C<br />

frame and cover etc. complete.<br />

16.1 This item includes all materials and labour mentioned hereafter,<br />

bricks, RCC Cover, excavation, laying cement concrete, B.B.<br />

masonry, plastering and refilling. The precast cover shall be tested<br />

and the results for approved before fixing the same.<br />

16.2 Brick Masonry:<br />

Burnt brick shall be the best available locally and kiln burnt, the<br />

minimum compressive strength shall be 40 kg/cm2. Bricks shall be<br />

tested as per relevant IS for every 50,000 Nos. The sizes and<br />

physical requirements of bricks shall be as per standard<br />

<strong>specifications</strong> of B & C Department, Govt. of <strong>Maharashtra</strong> and<br />

conforming to IS: 1877.