Technical information<br />

Maximum nominal heat input (heating)<br />

Minimum nominal heat input (heating)<br />

Maximum nominal heat output (heating)<br />

Minimum nominal heat output (heating)<br />

Effic<strong>ie</strong>ncy at nominal heat output (80/60 °C)<br />

Effic<strong>ie</strong>ncy at 30% of load (80/60 °C)<br />

Effic<strong>ie</strong>ncy at nominal heat output (<strong>50</strong>/30 °C)<br />

Effic<strong>ie</strong>ncy at 30% of load (<strong>50</strong>/30 °C)<br />

Effic<strong>ie</strong>ncy at nominal heat output (40/30 °C)<br />

Effic<strong>ie</strong>ncy at 30% of load (40/30 °C)<br />

Stack losses with burner on<br />

Stack losses with burner off<br />

Casing losses with burner on<br />

Casing losses with burner off<br />

Gas consumption at nominal heat output (heating)*<br />

Fumes temperature at max. nominal heat input*<br />

Fumes temperature at min. nominal heat input*<br />

Fumes flow rate at max. nominal heat input*<br />

Fumes flow rate at min. nominal heat input*<br />

CO2 at maximum heat input*<br />

CO2 at minimum heat input*<br />

CO at maximum heat input with 0% of O2*<br />

CO at minimum heat input with 0% of O2*<br />

NOx at maximum heat input with 0% of O2*<br />

NOx at minimum heat input with 0% of O2*<br />

Weighted CO*<br />

Weighted NOx *<br />

NOx class<br />

Central heating temperature range<br />

Maximum heating temperature<br />

Maximum operating pressure<br />

Available head with 1000 l/h flow rate<br />

Dimensions<br />

Height<br />

Width<br />

Depth<br />

Electrical supply<br />

Nominal power draw<br />

Installed electric power<br />

Fan power consumption<br />

Circulator power consumption<br />

Protection index<br />

Boiler water content<br />

Full appliance weight<br />

* With natural gas<br />

Unit of measurement<br />

kW<br />

kW<br />

kW<br />

kW<br />

%<br />

%<br />

%<br />

%<br />

%<br />

%<br />

%<br />

%<br />

%<br />

%<br />

m3/h °C<br />

°C<br />

kg/h<br />

kg/h<br />

%<br />

%<br />

ppm<br />

ppm<br />

ppm<br />

ppm<br />

mg/kWh<br />

mg/kWh<br />

-<br />

°C<br />

°C<br />

bar<br />

kPa<br />

mm<br />

mm<br />

mm<br />

V / Hz<br />

A<br />

W<br />

W<br />

W<br />

IP<br />

litres<br />

Kg<br />

VICTRIX <strong>50</strong><br />

<strong>50</strong>,8<br />

10,4<br />

<strong>50</strong>,0<br />

10,0<br />

98,5<br />

96,0<br />

106,0<br />

106,5<br />

107,0<br />

107,0<br />

1,3<br />

0,02<br />

0,2<br />

0,47<br />

5,37<br />

38<br />

30<br />

81<br />

17<br />

9,3<br />

9,0<br />

120<br />

6<br />

39<br />

16<br />

38<br />

55<br />

5<br />

20 - 85<br />

90<br />

4,4<br />

52,9<br />

9<strong>50</strong><br />

600<br />

525<br />

230 / <strong>50</strong><br />

0,85<br />

180<br />

59<br />

115<br />

X5D<br />

3,7<br />

69<br />

VICTRIX 75<br />

74,6<br />

18,5<br />

72,6<br />

18,1<br />

97,3<br />

101,0<br />

104,5<br />

107,6<br />

107,0<br />

107,6<br />

2,3<br />

0,01<br />

0,4<br />

0,32<br />

7,90<br />

61<br />

48<br />

121<br />

31<br />

9,2<br />

8,9<br />

170<br />

7<br />

108<br />

54<br />

43<br />

<strong>50</strong><br />

5<br />

20 - 85<br />

90<br />

4,4<br />

65,5<br />

9<strong>50</strong><br />

600<br />

525<br />

230 / <strong>50</strong><br />

1,26<br />

270<br />

72<br />

168<br />

X5D<br />

4,0<br />

72<br />

17