<strong>Designed</strong> <strong>for</strong> <strong>savings</strong> & <strong>efficiency</strong><br />
G3 LED parking & under canopy series<br />
www.sitelighting.com<br />
1
<strong>Designed</strong> with flexibility in mind<br />
Philips <strong>Gardco</strong> engineers set out to create a solution to address all of the specific lighting and energy <strong>savings</strong> needs <strong>for</strong><br />
any parking garage application. Whether you are looking <strong>for</strong> the lowest wattage LED based solution to meet IES design<br />
criteria with our single board 38 watt 3,431 lumen solution, or you desire enhanced security and light levels with our four<br />
board 137 watt 13,724 lumens, the G3 has you covered. Combine this modular per<strong>for</strong>mance with the latest in standalone<br />
or wireless controls <strong>for</strong> added energy <strong>savings</strong> and even more design flexibility and security, the G3 provides the industry’s<br />
most comprehensive parking garage solution package available today.<br />
2 www.sitelighting.com
A modular approach<br />
Lowest wattage two fixture per bay solution<br />
G3’s lowest wattage solution is a single 16 LED array that consumes 38 watts per fixture or 76 watts combined in a typical<br />
two fixture per bay solution. Meets all current IES RP20 design guidelines and minimums and is one of the lowest wattage<br />
fixtures if not lowest that will meet proposed future changes to IES garage design criteria. <strong>Designed</strong> to replace a 150 watt<br />
pulse start system one-<strong>for</strong>-one consuming 189 system watts per fixture, the G3 by itself saves 80% in energy usage.<br />
Lowest cost one fixture per bay solution<br />
For a lowest installed cost solution that still provides 72% in energy <strong>savings</strong> vs. traditional 150 watt pulse start systems, the<br />
dual 16 LED array G3 consumes 106 watts per fixture and can meet both current and proposed future IES guidelines one<br />
fixture per bay with our 1R optic vs. the typical two LED or HID luminaires. Reduce your fixture requirements, installation<br />
costs and system maintenance by 50% <strong>for</strong> the lowest total cost of ownership.<br />
Enhanced light levels <strong>for</strong> improved safety and security<br />
Some applications require enhanced or higher lighting levels than what the IES RP20 recommends when improved safety<br />
and security is a top priority. This typically means increased average footcandle levels and use of additional fixtures. G3’s<br />
modular design uses one to four 16 LED arrays that delivers up to 13,724 lumens. You now have the flexibility of utilizing<br />
higher lumen packages in single or two fixture per bay applications to provide enhanced light levels.<br />
Standalone motion response controls provides additional energy <strong>savings</strong><br />
Integral standalone motion response controls has just about become an industry standard in parking garage applications<br />
where additional energy <strong>savings</strong> is a top priority. G3 is no exception and can save you an additional 15% in energy usage<br />
during unoccupied times. This is the simplest controls solution available today as no additional wiring or commissioning is<br />
required at installation. Fixtures can be easily updated in the field using a wireless hand held programmer.<br />
Wireless control solution enhances security, flexibility and user experience<br />
G3’s wireless LimeLight control system provides the ultimate in fixture control and monitoring available today. Zones can be<br />
configured so that when motion is detected, the patron experiences a seamless visual experience that standalone controls<br />
cannot equal without complicated and expensive wiring. Accessible via the web based GUI, the G3 installed site can be<br />
monitored and updated in real time, including status reports of every fixture <strong>for</strong> added security and improved maintenance.<br />
www.sitelighting.com<br />
3
4 www.sitelighting.com<br />
Every year 6.5 billion kilowatt hours<br />
are wasted on parking garage<br />
lighting – that amounts to over<br />
$2 million a day, $730 million a year.
Lowest wattage two fixture per bay solution<br />
maximizes energy <strong>savings</strong><br />
At 38 watts per fixture, the G3’s single 16 LED array is one of the lowest wattage parking garage luminaires available today<br />
that meets all current IES RP20 design guidelines and is quite possibly the lowest wattage system that can meet current future<br />
proposed changes to IES design criteria. By simply converting to or choosing an all LED solution, the G3 was designed to replace<br />
100-150 watt PSMH 2-per bay systems one-<strong>for</strong>-one or by using less fixtures. At minimum you can expect to save 80% in energy<br />
consumption alone compared to the 189 system watts of a 150 watt PSMH luminaire.<br />
2-fixture per bay design<br />
Technical References:<br />
1. IESNA <strong>Lighting</strong> Handbook 10th Edition. Table 26.2.2.<br />
G3-5-1-38LA-NW-UNIV-NP<br />
Energy<br />
analysis<br />
Light levels<br />
Area<br />
(sq ft)<br />
Units<br />
Total Watts<br />
(per unit)<br />
Total Install<br />
Watts<br />
150W HID 75,438 80 189 15,120<br />
G3 LED 75,438 80 38 3,040<br />
Average Max Min Avg/Min Max/Min<br />
Horizontal fc - 150W HID 6.4 10.7 2.5 2.6 4.3<br />
Horizontal fc - G3 LED 3.1 4.9 1.1 2.8 4.4<br />
Vertical fc - 150W HID 5.1 7.3 2.2 2.3 3.3<br />
Vertical fc - G3 LED 1.1 1.2 0.9 1.2 1.3<br />
Values are based on standard 150 watt pulse start HID and G3-5-1-38LA-NW luminaires.<br />
Reflectance: ceiling - 40%, walls - 30%, and floor - 20%, at a 9.0’ wall height and 8.5’ fixture height.<br />
Fixtures spaced 26’ apart and 30’ between rows.<br />
Vertical fc values are based on readings taken 5’ above grade; meters facing towards luminaires.<br />
Typical garage layout designed not to be below current IES RP20 minimums.<br />
Total energy<br />
<strong>savings</strong>:<br />
80%<br />
G3 provides 80% energy<br />
<strong>savings</strong> compared to traditional<br />
150 watt pulse start solutions<br />
www.sitelighting.com<br />
5
Minimize total cost of ownership using a one<br />
fixture per bay solution without sacrificing<br />
energy <strong>savings</strong> and per<strong>for</strong>mance<br />
You have a tight budget and are concerned with total cost of ownership, return on investment and you still want to maximize<br />
energy <strong>savings</strong> as much as possible. The G3 has you covered by utilizing our 2-board 106 watt luminaire that delivers 8,810<br />
lumens combined with our ‘1R’ rectangular optic. This configuration was designed specifically to meet IES minimum criteria with a<br />
single fixture spaced down the center of a typical 60’ wide garage bay vs. the traditional two LED or traditional source luminaires.<br />
Not only can you reduce your total fixture count by 50% or more, but you also reduce installation costs, maintenance costs and<br />
optional controls costs by choosing a 1-per bay solution. And you receive all of these added benefits while still saving a significant<br />
amount of consumed energy compared to traditional luminaires.<br />
1-fixture per bay design<br />
Technical References:<br />
1. IESNA <strong>Lighting</strong> Handbook 10th Edition. Table 26.2.2.<br />
6 www.sitelighting.com<br />
G3-1R-2-106LA-NW-UNIV-NP<br />
Energy<br />
analysis<br />
Light levels<br />
Area<br />
(sq ft)<br />
50% reduction in fixture count, installation<br />
and maintenance costs with one fixture<br />
per bay and still saves 68% in energy<br />
Units<br />
Total Watts<br />
(per unit)<br />
Total Install<br />
Watts<br />
150W HID 75,438 80 189 15,120<br />
G3 LED 75,438 45 106 4,770<br />
Total energy<br />
<strong>savings</strong>:<br />
68%<br />
Average Max Min Avg/Min Max/Min<br />
Horizontal fc - 150W HID 6.4 10.7 2.5 2.6 4.3<br />
Horizontal fc - G3 LED 4.7 12.8 1.0 4.7 12.8<br />
Vertical fc - 150W HID 5.1 7.3 2.2 2.3 3.3<br />
Vertical fc - G3 LED 0.7 0.8 0.6 1.1 1.3<br />
Values are based on standard 150 watt pulse start HID and G3-5-2-106LA-NW luminaires.<br />
Reflectance: ceiling - 40%, walls - 30%, and floor - 20%, at a 9.0’ wall height and 8.5’ fixture height.<br />
Fixtures spaced 26’ apart and 30’ between rows.<br />
Vertical fc values are based on readings taken 5’ above grade; meters facing towards luminaires.<br />
Typical garage layout designed not to be below current IES RP20 minimums.
G3-5-3-104LA-NW-UNIV-NP<br />
Energy<br />
analysis<br />
Light levels<br />
Area<br />
(sq ft)<br />
Units<br />
Total Watts<br />
(per unit)<br />
Total Install<br />
Watts<br />
150W HID 75,438 80 189 15,120<br />
G3 LED 75,438 80 104 8,320<br />
Average Max Min Avg/Min Max/Min<br />
Horizontal fc - 150W HID 6.4 10.7 2.5 2.6 4.3<br />
Horizontal fc - G3 LED 9.2 14.6 3.4 2.7 4.3<br />
Vertical fc - 150W HID 5.1 7.3 2.2 2.3 3.3<br />
Vertical fc - G3 LED 3.23 3.5 2.7 1.2 1.3<br />
Values are based on standard 150 watt pulse start HID and G3-5-3-104LA-NW luminaires.<br />
Reflectance: ceiling - 40%, walls - 30%, and floor - 20%, at a 9.0’ wall height and 8.5’ fixture height.<br />
Fixtures spaced 26’ apart and 30’ between rows.<br />
Vertical fc values are based on readings taken 5’ above grade; meters facing towards luminaires.<br />
Typical garage layout designed not to be below current IES RP20 minimums.<br />
G3’s modular design provides<br />
additional lumen packages to address<br />
your enhanced security needs<br />
Total energy<br />
<strong>savings</strong>:<br />
45%<br />
2-fixture per bay design<br />
Technical References:<br />
1. IESNA <strong>Lighting</strong> Handbook 10th Edition. Table 26.2.2.<br />
Have an application that needs higher than normal<br />
light levels <strong>for</strong> improved safety and security and<br />
you cannot add additional fixtures<br />
Some applications require a 5 footcandle average or higher to provide enhanced safety and security within their structure, while others<br />
just want more illumination. Hi traffic installations such as hospitals, casinos, shopping malls, etc. are just a few examples where IES minimum<br />
criteria may not suffice. Most LED based solutions are limited in their lumen package offering, designing to the most efficient solution, which<br />
means additional fixtures to achieve higher light levels. The G3 still offers those efficient solutions and thanks to our modular design we are<br />
able to provide additional 2, 3 and 4 board configurations up to 13,724 lumens. Enhanced light levels in one or two fixture per bay designs<br />
are easily achieved without having to decrease lateral spacing or adding fixtures to increase light levels while still maximizing <strong>savings</strong>.<br />
www.sitelighting.com<br />
7
Energy saving economics<br />
G3 offers superior energy and operating cost saving solutions as a standalone fixture or with our<br />
programmable MR motion response detectors or LimeLight wireless control options. Our MR system provides<br />
efficient motion and ambient detection without the expense and complexity of more traditional wired control<br />
systems making the G3 luminaire the simplest controlled solution <strong>for</strong> parking garage applications.<br />
Energy <strong>savings</strong> with G3 (no controls)<br />
Energy analysis<br />
Our MR option is a standalone smart system ready from the<br />
factory and is 100% integral to the luminaire, requiring no<br />
additional wiring or commissioning during installation.<br />
Sensors<br />
G3’s MR sensors have the ability to detect and adjust to<br />
motion and ambient light levels. MR sensors can be designed<br />
with a maximum 25’ diameter reach at a 9’ mounting height.<br />
Standard dim level low is set to 10%, at the factory.<br />
Fully field programmable<br />
Every application is unique, requiring specific control settings<br />
that can be changed by the MR’s wireless IR handheld<br />
programmer. The ‘FSIR-100’ handheld programmer provides<br />
simple step-by-step navigation via wireless access directly to<br />
the sensor to change multiple parameters quickly and easily<br />
in the field. Custom factory programming also available if field<br />
commissioning is not an option.<br />
See G3-MR spec sheet <strong>for</strong> factory preset settings and field programming instructions.<br />
8 www.sitelighting.com<br />
G3-5-1-38LA 2 150 PSMH 2<br />
# of units* 132 132<br />
watts per unit 38 189<br />
total installed system watts 5,016 24,948<br />
kWh usage/yr 43,940 218,544<br />
kWh <strong>savings</strong>/yr* 174,604<br />
kWh rate $0.12<br />
$ saved/yr 1 $20,952<br />
1. G3 system wattage <strong>savings</strong> only without use of any controls.<br />
2. Analysis is based on a new construction, comparing a traditional 150 watt 2-fixture per bay HID pulse<br />
start system to a 2-fixture per bay G3 system @ 24 hrs/day and 365 days/yr operation.<br />
MR motion response sensor<br />
9’<br />
0’<br />
25’ 20’ 15’ 10’ 5’ 0’ 5’ 10’ 15’ 20’ 25’<br />
Horizontal detection<br />
Achieve 80%<br />
kWh <strong>savings</strong><br />
by switching from<br />
HID to a G3<br />
solution with no<br />
controls<br />
Vertical detection<br />
FSIR-100<br />
25’<br />
12.5’<br />
0’<br />
12.5’<br />
25
How MR motion response works<br />
Simply use the factory MR sensor profile or specifically configure the system to the desired settings (field or factory). Luminaires will operate<br />
at the programmed light levels during unoccupied periods. When motion is detected at vehicular or pedestrian entry points, the system<br />
will immediately raise light levels to 100% or per programmed levels. Luminaires will then remain at high-output until the set time-out<br />
period has elapsed that can range from 30 seconds to 30 minutes.<br />
motion<br />
detection<br />
Fixtures activated to 100%.<br />
Fixtures pre-set to 10%.<br />
West<br />
5:00 pm<br />
33-50%<br />
fixtures at low<br />
1:00 pm 11:00 am 8:00 am<br />
100%<br />
fixtures at low<br />
33-50%<br />
fixtures at low<br />
East<br />
Power at low:<br />
Total Annual energy <strong>savings</strong> with G3-MR by occupancy level 2<br />
Average occupancy level<br />
No<br />
Dimming 1<br />
30% 40% 50% 60% 70% 100%<br />
10% $24,274 $23,800 $23,325 $22,851 $22,376 $20,952<br />
20% $23,905 $23,483 $23,062 $22,640 $22,218 $20,952<br />
30% $23,536 $23,167 $22,798 $22,429 $22,060 $20,952<br />
40% $23,167 $22,851 $22,534 $22,218 $21,902 $20,952<br />
50% $22,798 $22,534 $22,271 $22,007 $21,743 $20,952<br />
60% $22,429 $22,218 $22,007 $21,796 $21,585 $20,952<br />
No Dimming1 100% $20,952 $20,952 $20,952 $20,952 $20,952 $20,952<br />
1. G3-5-1-38LA <strong>savings</strong> only without use of any controls.<br />
2. Analysis is based on a new construction, comparing a traditional HID 2-fixture per bay 150W HID pulse<br />
start system to a 2-fixture per bay G3 system @ 24 hrs/day and 365 days/yr operation at multiple<br />
power and occupancy levels.<br />
Energy <strong>savings</strong> with G3-MR and<br />
daylight harvesting<br />
G3-MR fixtures will detect ambient light levels to provide additional energy<br />
saving opportunities <strong>for</strong> installations where direct daylight is available.<br />
During installation, an auto set-point feature automatically detects artificial<br />
and ambient light levels <strong>for</strong> automated calibration. The unit will remain at a<br />
lower light level mode until natural light levels decrease to the point where<br />
artificial electric light contributions are once again required.<br />
Software programs such as AGi32 have full daylight harvesting capabilities to determine light levels<br />
delivered by the sun at anytime of day, year, and weather conditions.<br />
For assistance, contact Philips <strong>Gardco</strong> applications group at www.sitelighting.com.<br />
Save an additional $3,322<br />
annually or 12.7% with<br />
G3-MR controls at 30%<br />
occupancy and 10% low<br />
www.sitelighting.com<br />
9
Wireless controls create a<br />
smarter cost <strong>savings</strong> solution<br />
G3 is available with LimeLight’s cutting-edge wireless controls system. When<br />
fully leveraging all aspects of the LimeLight system, you can determine your peak<br />
hours of operation, minimize energy consumption and have the ability to modify<br />
your light levels according to your facility’s usage patterns based on occupancy<br />
activity and daylight harvesting. This allows end-users to minimize energy<br />
consumption and reduce wasted illumination by perfectly calibrating their garage<br />
<strong>for</strong> maximum per<strong>for</strong>mance and <strong>savings</strong>.<br />
Features<br />
10 www.sitelighting.com<br />
LED solutions alone achieve as<br />
much as 80% energy <strong>savings</strong><br />
compared to traditional sources,<br />
and can reach up to 95% <strong>savings</strong><br />
when coupled with smart controls 1<br />
Wireless<br />
controls<br />
system<br />
Standalone<br />
controls<br />
system<br />
Requires no additional wiring during installation ü ü<br />
Motion and Daylight Sensor provides full 360°<br />
detection range ü ü<br />
Lengthens life of luminaire and electrical<br />
components ü ü<br />
Fixtures are fully programmable in the eld ü ü<br />
Individual xtures, groups, or entire facility are<br />
programmable from any remote computer ü <br />
Fixtures can be grouped according to location<br />
without complicated additional wiring schemes ü <br />
System can report energy usage, occupancy rates<br />
and occupancy times ü <br />
Allows you to temporarily override schedules <strong>for</strong><br />
special events at the click of a mouse ü <br />
Noties you after a power outage ü <br />
Sends email alert notications of system status<br />
and failure conditions ü <br />
22<br />
14<br />
12<br />
10<br />
8<br />
6<br />
4<br />
2<br />
0<br />
04/19/12<br />
00.00<br />
04/20/12<br />
00.00<br />
LimeLight Energy Gauge<br />
04/21/12<br />
00.00<br />
04/22/12<br />
00.00<br />
04/23/12<br />
00.00<br />
Scheduled/Reactive Events<br />
Previous Fixture Peak 24/7<br />
Energy Harvesting LimeLight System Peak 24/7<br />
Superior<br />
management<br />
and control<br />
capability<br />
04/24/12<br />
00.00<br />
All On (kwHr)<br />
Actual (kwHr)<br />
844.6<br />
Actual vs. All on Savings<br />
LimeLight Control Factor<br />
45.7%<br />
Daily Data Only<br />
When coupled with G3 luminaires, LimeLight’s<br />
wireless system features all of the benefits of<br />
traditional standalone control systems with the<br />
added ability to wirelessly communicate with your<br />
system to provide an optimal and safe experience<br />
<strong>for</strong> the customer and facility manager.<br />
15555<br />
Load<br />
Exit<br />
Rate (kwHr)<br />
0.080<br />
Cost<br />
$124.44<br />
Cost<br />
$67.57<br />
1 Percentages are based on Philips <strong>Gardco</strong>’s G3 luminaire with motion response<br />
and wireless controls compared to 150 watt PSMH systems.<br />
$56.8
Understanding wireless technology<br />
LimeLight’s wireless technology is a web-based system that operates through high density mesh<br />
(HDM) wireless technology. The diagram below demonstrates how all of the components of<br />
our wireless system work together to create a true mesh network. The system starts with the<br />
web based graphical user interface (GUI), which is accessed to view fixture status and to manage<br />
the luminaires in the parking garage. All of the commands to the system go through the central<br />
LimeLight database, which receives in<strong>for</strong>mation from the LimeLight Gateway and checks the<br />
status of every fixture.<br />
1. Graphical User<br />
Interface (GUI)<br />
2. Central<br />
Limelight<br />
Database<br />
3. Customer<br />
Firewall<br />
Eliminate the<br />
‘popcorn effect’ of single<br />
luminaire dimming control<br />
Although widely accepted, individual fixture control is true line-of-sight,<br />
which means each luminaire is brought to high output only when motion<br />
is detected. This creates a visual domino or ‘popcorn effect’ as a patron<br />
or vehicle makes their way through the space.<br />
Thanks to LimeLight’s ability to easily create fixture groups or lighting<br />
zones, patrons will never see any change in illumination levels and will<br />
always be in a fully illuminated space until exiting the parking structure.<br />
Eliminating the undesirable domino or popcorn effect to create a<br />
seamless, safe and inviting visual experience.<br />
After the patron has safely exited the garage, the previously activated<br />
zones gradually dim back to their low state as long as no additional<br />
occupancy is detected. This time delay can be easily programmed to<br />
specific settings to further ensure safety and security as well as maximize<br />
energy saving potential.<br />
2nd Floor<br />
1st Floor<br />
4. The Gateway 4. LED Luminaires<br />
A parking patron enters the third floor to retrieve their<br />
vehicle, illuminating the entire floor upon entering<br />
As the patron exits the garage, the luminaires on the next<br />
level illuminate to full power be<strong>for</strong>e the vehicle makes the turn<br />
www.sitelighting.com<br />
11
Maximize <strong>savings</strong><br />
and decrease risk<br />
with real-time data<br />
feedback<br />
Measuring activity can<br />
improve energy <strong>efficiency</strong><br />
LimeLight tracks energy usage by groups, floors<br />
or individual fixtures. The beauty of the system<br />
allows owners to evaluate energy consumption<br />
by generating daily, weekly and quarterly reports<br />
using the on-line reporting tool. This feature allows<br />
users to modify light level presets and scheduling<br />
events straight from the web. Furthermore, when<br />
conducting daylight harvesting and occupancy<br />
activity analysis, wattage reduction calculation and<br />
opportunities <strong>for</strong> further adjustments can be verified<br />
with real-time data feedback.<br />
Up to 50% installation and maintenance cost<br />
<strong>savings</strong> compared to hard wired control systems<br />
Enhance fixture and system reliability <strong>for</strong> your customers<br />
and reduce maintenance costs<br />
Because you can view your facility’s lighting status from any remote location, maintenance has never<br />
been easier. The system will e-mail or text you directly in the event of a power outage, fixture failure<br />
or drop in light levels. System outages and sudden drops in illumination can be tracked immediately to<br />
individual fixtures. As a result, maintenance issues can be automatically diagnosed be<strong>for</strong>e a repair crew is<br />
dispatched. No more guessing or costly spot checking to ensure peace of mind that your facility is 100%<br />
operational and safe.<br />
12 www.sitelighting.com<br />
“The wireless controls system tracks<br />
energy usage, dims fixtures when there<br />
is no activity or in areas of strong natural<br />
light, and provides the kind of real-time<br />
data that garage owners need.”<br />
- Municipal User<br />
Installing a wireless system eliminates the need <strong>for</strong> dedicated control wiring, circuitry and design, reducing hard wire and labor<br />
expenses during installation. With little to no installation disruptions during daily operation combined with the elimination and need<br />
<strong>for</strong> maintenance spot checking, wireless controls are proven to be an ideal solution <strong>for</strong> retrofit and relight applications to significantly<br />
reduce costly facility maintenance.
Leveraging the intelligence<br />
of the system via the web<br />
LimeLight’s graphical user interface (GUI) is truly the power of the system<br />
enabling you to manage your entire parking garage facility lighting via<br />
the web. Every fixture has its own MAC address so owners can check<br />
the status of a single fixture and any fixture can be interdependent or<br />
independent in terms of grouping. The GUI is a web based tool that can<br />
be accessed straight from the internet, requiring no additional software<br />
installation. Each user will receive a unique user name and password to<br />
access the LimeLight user interface. There are five levels of access to<br />
ensure that the owner, building operator, or security manager can access<br />
only the in<strong>for</strong>mation they need.<br />
Manage and monitor fixture<br />
groupings in real time<br />
LimeLight’s grouping tool provides tremendous flexibility<br />
with up to 50 fixture groups per gateway. Group the<br />
entire floor or individual rows to provide full line-of-sight<br />
views <strong>for</strong> your customer in the evening hours, or group<br />
the entrance areas to keep fixtures at maximum light<br />
output regardless of the time of day.<br />
The flexibility and control is yours. After initial<br />
configuration, you have the ability to change and update<br />
individual fixtures and groups as required. Thanks to<br />
the wireless communication, changes are done in real<br />
time and from the ease of your computer. No need to<br />
manually reprogram each individual luminaire in the field<br />
like other traditional standalone or wired installations.<br />
Event programming is as<br />
easy as 1, 2, 3<br />
LimeLight’s wireless access allows users to set up multiple<br />
program events to accommodate activities such as<br />
maintenance, manual, reactive and high occupancy level<br />
schedules. If you need to override your active schedule<br />
<strong>for</strong> holidays, sporting events, or other special occasions,<br />
simply log on to the portal and create a specific event<br />
program. Again, this is all done in real time without having<br />
to manually reprogram in the field. The regular scheduled<br />
event will resume automatically the next day.<br />
LimeLight’s GUI allows you to control light levels and operate in large or small zones, or<br />
by multiple floors to best suit your parking garage’s needs all in real time without having<br />
to reprogram each fixture in the field like traditional control systems.<br />
Scheduling special events and adjusting light levels are easily achieved directly from your<br />
computer on-site or by remote web access.<br />
www.sitelighting.com<br />
13
G3 LED Garage Ordering Matrix<br />
‘G3-MR’ 1-board shown<br />
‘G3-MR’ 2-board shown<br />
Ordering In<strong>for</strong>mation<br />
Prefix<br />
Finish<br />
Prefix<br />
G3<br />
G3-DIM<br />
G3-MR 1<br />
G3-MRCP 1,2<br />
G3-RC 3<br />
¨ NP Natural Aluminum Paint<br />
-<br />
14 www.sitelighting.com<br />
Optical System LED Array & Wattage LED Selection Voltage Finish Options<br />
5<br />
5DL<br />
3<br />
1R 4<br />
CD<br />
¨ G3 G3 LED garage<br />
¨ G3-DIM G3 w/ 0-10V Dimming<br />
¨ G3-MR1 G3 w/ Motion Response<br />
¨ G3-MRCP1,2 G3 w/ Motion Response<br />
Factory Programming<br />
¨ G3-RC3 G3 w/ LimeLight wireless<br />
- - -<br />
Options<br />
1-38LA 5<br />
1-55LA 5<br />
2-73VAR 5<br />
2-106LA 4,5<br />
3-104LA<br />
4-137LA<br />
¨ F Fusing<br />
Optical System<br />
- -<br />
NW<br />
CW<br />
WW<br />
¨ 5 Type 5 Symmetrical<br />
¨ 5DL Type 5 Diffuse Lens<br />
¨ 3 Type 3 Asymmetrical<br />
¨ 1R 4 Type 1R Rectangular<br />
¨ CD Concentrated<br />
Downlight<br />
UNIV 1,3,5<br />
HVU<br />
LED Array & Wattage<br />
¨ 1-38LA5 1-board, 38W, variable<br />
¨ 1-55LA5 1-board, 55W, fixed<br />
¨ 2-73VAR5 2-board, 73W, variable<br />
¨ 2-106LA4,5 2-board, 106W, fixed<br />
¨ 3-104LA 3-board, 104W, fixed<br />
¨ 4-137LA 4-board, 137W, fixed<br />
¨ MTP Thermal Temperature Protection<br />
¨ PCB6 Photocontrol Button ¨ QDM Driver Quick Disconnect Module<br />
Notes:<br />
1. ‘MR’ and ‘MRCP’ motion response only available in 120 or 277V.<br />
2. ‘MRCP’ custom factory programming requires approved submittals to set factory profile.<br />
3. ‘RC’ wireless limelight control only available in ‘UNIV’ 120-277V.<br />
4. ‘1R’ was designed to meet IES minimums with single fixture per bay in the 2-board/106W ‘2-106LA’ configuration.<br />
5. Only available in ‘UNIV’ 120-277V.<br />
6. ‘PCB’ photocontrol button is 120-277V, not available with ‘G3-RC’ wireless option as it is not required.<br />
7. ‘BX’ bird excluding shroud is <strong>for</strong> ‘PB-NP’ pendant mount only. Field installed and requires 12” minimum pendant length. Pendant by others.<br />
8. ‘FSIR-100’ is <strong>for</strong> use with ‘MR’ motion response when field programming is required. Minimum one required per job.<br />
70 o<br />
70 o<br />
90 o<br />
90 o<br />
‘5’ Symmetrical<br />
0 o<br />
90 o<br />
70 o<br />
90 o<br />
50 o<br />
67.5 o<br />
NP F<br />
PCB 6<br />
LED Selection<br />
MTP<br />
QDM<br />
¨ NW 4,000K, 75CRI<br />
¨ CW 6,000K, 75CRI<br />
¨ WW 3,000K, 75CRI<br />
‘3’ Asymmetrical<br />
‘1R’ Rectangular ‘CD’ Concentrated Downlight<br />
0 o<br />
90 o<br />
70 o<br />
90 o<br />
50 o<br />
90 o<br />
90 o<br />
35 o<br />
Voltage<br />
Accessories (must be ordered separately)<br />
0 o<br />
0 o<br />
Accessories<br />
BX 7<br />
PB-NP 7<br />
FSIR-100 8<br />
¨ UNIV 120-277V1,3,5 ¨ HVU 347-480V<br />
¨ BX7 Bird Excluding Shroud (field installed)<br />
¨ PB-NP7 Balanced J-box <strong>for</strong> Pendant Mount (natural paint)<br />
¨ FSIR-1008 MR Handheld Programmer<br />
0 o<br />
0 o<br />
50 o<br />
90 o<br />
90 o<br />
50 o<br />
35 o<br />
90 o<br />
90 o<br />
67.5 o<br />
90 o<br />
60 o<br />
90 o<br />
60 o
Technical data<br />
System<br />
Watts 1<br />
Specifications<br />
Initial Lumens<br />
@ 25°C 2<br />
LPW @<br />
25°C 2<br />
Rated System Life (LED life per L70 minimum)<br />
Driver and LED life: 100,000 hrs @ 25° (77°F)<br />
75,000 hrs @ 40°C (104°F)<br />
Construction<br />
Modular die-cast driver housing with die-cast LED array<br />
heatsink assemblies (1 to 4). Standard unit constructed to<br />
IP66 driver housing with dedicated IP66 optical assemblies.<br />
Motion response option is IP65.<br />
Energy Saving Benefits<br />
System efficacy up to 109 lms/W with energy <strong>savings</strong> up<br />
to 80% over PSMH systems less controls. Meets DLC<br />
compliant guidelines. Optional MR motion response<br />
sensor provides added energy <strong>savings</strong> up to 95% during<br />
unoccupied periods and works as a ‘Smart Fixture’<br />
requiring no added wiring or commissioning at install.<br />
Driver<br />
Driver <strong>efficiency</strong> (>90% standard). 120-480V available<br />
(restrictions apply). Temp range: -40°C (-40°F) to 50°C<br />
(122°F). Open/short circuit protection. Optional 0-10V<br />
dimming to 10% power. RoHS compliant. Surge protector<br />
standard and is in accordance with IEEE / ANSI C62.41.2<br />
guidelines, with a surge current rating of 10,000 amps.<br />
LED and Board Array<br />
Luxeon R LED only: 94-120 lms/W, System only: 80-109<br />
lms/W. Color temps: 3000K, 4000K, 5700K +/- 250K.<br />
Minimum CRI of 70. Aluminum metal clad board. RoHS<br />
compliant.<br />
Ideal Product Application<br />
(recommended but not limited to)<br />
1-38LA 38.38 3,431 89.40 lowest wattage, 2-per bay to meet IES minimum criteria<br />
1-55LA 55.42 4,465 80.57 low wattage, 2-per bay with improved IES avg’s and min’s<br />
2-73VAR 73.19 6,862 93.76 lowest wattage, 2-per bay to achieve 5 FC average<br />
2-106LA 105.70 8,810 83.35 lowest cost solution, 1-per bay with ‘1R’ optic to meet IES min’s<br />
3-104LA 104.44 10,293 98.55 high lumen package, 1-per bay, entrances, enhanced security, etc.<br />
4-137LA 137.43 13,724 99.86 highest lumen package, 1-per bay, entrances, enhanced security, etc.<br />
Notes: 1. Due to LED <strong>for</strong>ward voltage variations and driver <strong>efficiency</strong>, total system watts could vary +/-4%.<br />
2. Technical data and per<strong>for</strong>mance are subject to change, voltage restrictions may apply.<br />
Dimensions 1<br />
1 & 2-Board Front View<br />
(optional RC shown)<br />
17.13”<br />
(43.5 cm)<br />
standard mounting mounts<br />
to standard 4” square or<br />
octagonal j-boxes<br />
1-Board Top View<br />
(EZ Hanger Plate Mount, optional RC shown)<br />
10.68”<br />
(27.12 cm)<br />
13.31”<br />
(33.8 cm)<br />
Notes: 1. See detailed spec sheets <strong>for</strong> 3 and 4-board dimensions and additional mounting details.<br />
1-Board Side View<br />
(optional MR shown)<br />
10.68”<br />
(27.12 cm)<br />
3.20”<br />
(8.13 cm)<br />
Optical System<br />
Type-5 symmetrical, Type-3 asymmetrical, Type-1R<br />
rectangular and CD concentrated downlight. Type-1R with<br />
8,810 lumen package or higher is designed to meet IES mins<br />
with one fixture per parking bay compared to the typical<br />
two per bay. Diffuse lens is available to limit perceived<br />
luminaire brightness.<br />
Mounting<br />
Standard mounting shall include a galvanized steel Easy<br />
Hanger Plate. Unit may be pendant mounted to minimum<br />
12” rigid conduit by others with PB-NP balanced j-box.<br />
LimeLight Wireless Controls System<br />
LimeLight is an intelligent web-based system that operates<br />
through a high density mesh (HDM) wireless technology.<br />
Radio modules with motion and photocell sensors are<br />
integrated into each G3 LED luminaire that enables<br />
the fixtures to communicate with the ZigBee protocol.<br />
The Gateway is a mini computer that connects to the<br />
internet, and is located in the parking structure (120V<br />
required). The central LimeLight database channels<br />
communication to and from the gateway, allowing data to<br />
be viewed or accessed through the web-based graphical<br />
user interface (GUI).<br />
Motion Response Sensors<br />
G3-MR, G3-MRCP and G3-RC luminaires may be specified<br />
<strong>for</strong> additional energy <strong>savings</strong> during unoccupied periods<br />
by dimming to low until motion is detected via a passive<br />
infrared (PIR) motion sensor. Standard dim level factory<br />
set to 10% and can be factory or field programed.<br />
2-Board Top View<br />
(EZ Hanger Plate Mount, optional RC shown)<br />
15.59”<br />
(39.6 cm)<br />
1-Board Bottom View<br />
(optional MR shown)<br />
13.31”<br />
(33.8 cm)<br />
2-Board Bottom View<br />
(optional MR shown)<br />
2-Board Side View<br />
(optional MR shown)<br />
15.59”<br />
(39.6 cm)<br />
Listings<br />
ETL/cETL listed to the UL 1598 standard, suitable <strong>for</strong><br />
Wet Locations. Suitable <strong>for</strong> use in ambients from -40° to<br />
40°C (-40° to 104°F). Type-3, 5, 5DL and 1R optics are<br />
DesignLights Consortium qualified (in process). The quality<br />
systems of this facility have been registered by UL to the<br />
ISO 9001 series standards.<br />
Finish<br />
Each luminaire receives a fade and abrasion resistant,<br />
electrostatically applied, thermally cured, triglycidal<br />
isocyanurate (TGIC) textured polyester powder coat finish.<br />
Standard finish of all die-cast assemblies shall be Natural<br />
Aluminum paint.<br />
Warranty<br />
Luminaires feature a 1 year limited warranty. LED<br />
luminaires with LED arrays feature a 5 year limited<br />
warranty covering the LED arrays. LED drivers are<br />
covered by a 5 year limited warranty. PIR sensors carry<br />
a 5 year limited warranty from the sensor manufacturer.<br />
The LimeLight Wireless Controls System carries a 5 year<br />
limited warranty from the manufacturer. See Warranty<br />
In<strong>for</strong>mation on www.sitelighting.com <strong>for</strong> complete details<br />
and exclusions.<br />
All sales of items in this catalogue shall be subject to the Philips <strong>Gardco</strong><br />
Standard Terms and Conditions of Sale current at the time of shipment.<br />
If you do not have a copy of the Philips <strong>Gardco</strong> Warranty and Standard<br />
Terms, please contact the factory <strong>for</strong> same prior to ordering.<br />
DLC listing is in process.<br />
www.sitelighting.com<br />
3.2”<br />
(8.1 cm)<br />
15
16 www.sitelighting.com<br />
© 2011 Philips Group. All rights reserved.<br />
Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The in<strong>for</strong>mation presented in this<br />
document does not <strong>for</strong>m part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. No<br />
liability will be accepted by the publisher <strong>for</strong> any consequence of its use. Publication there of does not convey nor imply any license under<br />
patent- or other industrial or intellectual property rights. Data subject to change.<br />
© 2013 Koninklijke Philips Electronics N.V.<br />
All Document rights reserved. order number:<br />
Philips Wide-Lite Professional Luminaires<br />
1611<br />
1611<br />
Clovis<br />
Clovis<br />
R.<br />
Barker<br />
Barker<br />
Road<br />
Road<br />
San<br />
San<br />
Marcos,<br />
Marcos,<br />
Texas<br />
Texas<br />
78666<br />
78666<br />
PH:<br />
PH:<br />
512.753.1000<br />
1.512.392.5821<br />
FAX:<br />
FAX:<br />
512.753.7855<br />
1.512.753.1122<br />
www.sitelighting.com<br />
www.wide-lite.com<br />
022513