Requested model ________________________<br />

Requested version ceiling mounted wall mounted mobile<br />

Room height pls see page 2+3<br />

Transformer*<br />

external (Blocktransformer) installed at the ceiling flange<br />

LED operating lamps: Transformer housing with 1 power supply 250W for LED3 SC/MC & LED5 SC/MC<br />

Ceiling anchorage for ceiling mounted lamps<br />

Additional features for M3F/M3DF:<br />

<strong>Mach</strong> Intcon (light intensity control incl. electronic on/off switch)<br />

extra sterilizable handles ___________ pieces<br />

extra halogen bulbs ___________ pieces<br />

_________________________________________________________________________________<br />

*Additional information regarding transformers:<br />

a.) All lights operate with low voltage (range from 12V AC to 22,8V AC and 28V DC). If the light<br />

shall be connected to 120V/230V, it is absolutely necessary to order a transformer or power<br />

supply<br />

b.) The lights <strong>Mach</strong> 130, Triaflex, Trigenflex and <strong>Mach</strong> M2 are generally delivered inclusive<br />

transformer<br />

c.) All stand lights are delivered inclusive transformer<br />

d.) The LED lights are supplied with 24V DC up to 28V DC<br />

For all wall and ceiling models of lights <strong>Mach</strong> M3, M5, LED3MC, LED5MC, <strong>Mach</strong> 380 and 500<br />

the transfomer or power supply must be ordered separately (if necessary). The transformer<br />

and the power supply are <strong>list</strong>ed at the respective lights under the heading "Accessories<br />

e.) Toroid transformer: Due to its round shape this transformer can be installed within the light<br />

head (Tria-, Trigenflex) or at the ceiling flange (<strong>Mach</strong> M3, M5, <strong>Mach</strong> 380 and 500).<br />

Block transformer: Due to its square shape this transformer may either be installed directly in a<br />

separate current distribution box or in a transformer box (plastic box with transparent lid)<br />

suitable for (<strong>Mach</strong> 130, Tria-, Trigenflex, <strong>Mach</strong> M3, M5, <strong>Mach</strong> 380 and 500). The block<br />

transformer of <strong>Mach</strong> M2 is always mounted at the ceiling flange<br />

Electronic transformer: These regulated transformers are installed in the light head (<strong>Mach</strong><br />

130), wall bracket or handle at the stand tube (<strong>Mach</strong> 120, <strong>Mach</strong> M2


Which information are needed when ordering a <strong>Dr</strong>. <strong>Mach</strong> OP/Examination lamp?<br />

- Ceiling version -<br />

cm?<br />

cm?<br />

cm?<br />

Carrying ceiling<br />

1.) RH: Fixation height from floor to carrying ceiling<br />

(Please see graphic and state the dimensions when ordering!)<br />

Carrying ceiling<br />

False ceiling<br />

cm?<br />

2.) a. RH – Height from floor to carrying ceiling<br />

b. RH – FC: Room height from floor to lower edge of false ceiling<br />

(Please see graphic and state the dimensions when ordering!)<br />

lower edge of false ceiling<br />

(false ceiling = intermediate ceiling)<br />

Please take into account that in case of room height of 2,80m the maximum passing height is between<br />

1900 and 1950mm. This concerns the following ceiling models:<br />

M3/M5/LED3MC/LED5MC/<strong>Mach</strong>380/500/Trigenflex.<br />

All lamps for room height below 2,80m do not come with fully cardanic suspension but generally with<br />

special hanging adapted for low room heights.


Alternative information for rooms with closed false ceiling: e.g. Operation theatre<br />

Carrying ceiling<br />

False ceiling<br />

3.) a. RH – Height from floor to carrying ceiling<br />

b. RH – FC: Room height from floor to lower edge of false ceiling<br />

(Please see graphic and state the dimensions when ordering!)<br />

c. Rooms fitted with closed ceilings e.g. operation rooms may require an intermediate flange*<br />

For mounting in operating rooms with laminar flow ceilings please ask separately!