19.08.2013 Views

Catalog ST 80 / ST PC · 2011 - Siemens

Catalog ST 80 / ST PC · 2011 - Siemens

Catalog ST 80 / ST PC · 2011 - Siemens

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Human Machine Interface Systems/<br />

<strong>PC</strong>-based Automation<br />

<strong>Catalog</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> • <strong>2011</strong><br />

SIMATIC HMI / <strong>PC</strong>-based Automation<br />

Answers for industry.<br />

© <strong>Siemens</strong> AG <strong>2011</strong>


Related catalogs<br />

SIMATIC <strong>ST</strong> 70<br />

Products for<br />

Totally Integrated Automation<br />

and Micro Automation<br />

E86060-K4670-A101-B3-7600<br />

Industrial Communication IK PI<br />

SIMATIC NET<br />

E86060-K6710-A101-B6-7600<br />

Industrial Communication IK PI N<br />

SIMATIC NET<br />

E86060-K6710-A121-A3-7600 (News)<br />

SITOP KT 10.1<br />

Power supply<br />

SITOP<br />

E86060-K2410-A111-A7-7600<br />

SITRAIN ITC<br />

Training for Automation and<br />

Industrial Solutions<br />

Only available in German<br />

E86060-K6850-A101-C2<br />

<strong>Catalog</strong> CA 01 CA 01<br />

Products for Automation and Drives<br />

DVD: E86060-D4001-A510-C9-7600<br />

Industry Mall<br />

Information and Ordering Platform<br />

in the Internet:<br />

www.siemens.com/industrymall<br />

© <strong>Siemens</strong> AG <strong>2011</strong>


SIMATIC HMI /<br />

<strong>PC</strong>-based Automation<br />

Operator Control and<br />

Monitoring Systems<br />

<strong>Catalog</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Supersedes:<br />

<strong>Catalog</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> 2010<br />

Refer to the Industry Mall for current updates<br />

of this catalog:<br />

www.siemens.com/industrymall<br />

The products contained in this<br />

catalog can also be found in the<br />

Interactive <strong>Catalog</strong> CA 01.<br />

Order No.:<br />

E86060-D4001-A510-C9-7600<br />

Please contact your local <strong>Siemens</strong> branch<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

PEFC/04-31-1404<br />

Printed on paper<br />

from sustainably<br />

managed forests and<br />

controlled sources.<br />

www.pefc.org<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

The products and systems<br />

described in this<br />

catalog are manufactured/distributed<br />

under<br />

application of a certified<br />

quality management<br />

system in accordance<br />

with DIN EN ISO 9001<br />

(Certified Registration<br />

No. 2613-05). The certificate<br />

is recognized by all<br />

IQNet countries.<br />

Introduction 1<br />

Operator panels 2<br />

HMI devices for special requirements 3<br />

HMI Software 4<br />

<strong>PC</strong>-based Automation 5<br />

Customized Automation 6<br />

Appendix 7


1/2<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


<strong>Siemens</strong> offers automation, drive, and<br />

low-voltage switching technology as<br />

well as industrial software from standard<br />

products up to entire industry solutions.<br />

The industry software enables our<br />

industry customers to optimize the entire<br />

value chain – from product design<br />

and development through manufacture<br />

and sales up to after-sales service. Our<br />

electrical and mechanical components<br />

offer integrated technologies for the entire<br />

drive train – from couplings to gear<br />

units, from motors to control and drive<br />

solutions for all engineering industries.<br />

Our technology platform TIP offers robust<br />

solutions for power distribution.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Answers for industry.<br />

<strong>Siemens</strong> Industry answers the challenges in the<br />

manufacturing and the process industry as well as in<br />

the building automation business. Our drive and automation<br />

solutions based on Totally Integrated Automation (TIA) and<br />

Totally Integrated Power (TIP) are employed in all kinds<br />

of industry. In the manufacturing and the process industry.<br />

In industrial as well as in functional buildings.<br />

The high quality of our products<br />

sets industry-wide benchmarks.<br />

High environmental aims are part of<br />

our eco-management, and we implement<br />

these aims consistently. Right<br />

from product design, possible effects on<br />

the environment are examined. Hence<br />

many of our products and systems are<br />

RoHS compliant (Restriction of Hazardous<br />

Substances). As a matter of course,<br />

our production sites are certified according<br />

to EN ISO 14001, but to us,<br />

environmental protection also means<br />

most efficient utilization of valuable<br />

resources. The best example are our<br />

energy-efficient drives with energy<br />

savings up to 60 %.<br />

Check out the opportunities our<br />

automation and drive solutions provide.<br />

And discover how you can sustainably<br />

enhance your competitive edge with us.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

1/3


Management Level<br />

Operations Level<br />

Control Level<br />

Field Level<br />

Totally<br />

Integrated<br />

Automation<br />

1/4<br />

ERP – Enterprise Resource Planning<br />

MES – Manufacturing Execution Systems<br />

SIMATIC <strong>PC</strong>S 7<br />

Process Control (DCS)<br />

PROFIBUS PA<br />

HART<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Industrial Software for<br />

Product Design<br />

Production Planning<br />

Engineering<br />

SINUMERIK<br />

Computer Numerical Control<br />

Process Instrumentation<br />

Commissioning<br />

Operation<br />

Maintenance<br />

Modernization and Upgrade<br />

SIMOTION<br />

Motion Control<br />

SIMATIC Ident<br />

Industrial Identification<br />

SIMATIC NET<br />

Industrial<br />

Communication<br />

IO-Link<br />

SIMATIC IT<br />

Setting standards in<br />

productivity and competitiveness.<br />

Totally Integrated Automation.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC Controllers<br />

Modular / <strong>PC</strong>-based<br />

SIMATIC Distributed I/O<br />

Energy Management<br />

Asset Management


SIMATIC HMI<br />

Human Machine Interface<br />

SIMATIC WinCC<br />

SCADA-System<br />

Ethernet<br />

Ethernet<br />

Industrial Ethernet<br />

Industrial Ethernet<br />

SIRIUS Industrial Controls<br />

SINAMICS Drive Systems Low-Voltage Distribution<br />

PROFINET<br />

Industrial Ethernet<br />

PROFIBUS<br />

AS-Interface<br />

KNX GAMMA instabus<br />

Totally<br />

Integrated<br />

Power<br />

Thanks to Totally Integrated Automation, <strong>Siemens</strong> provides<br />

an integrated basis for the implementation of customized<br />

automation solutions – in all industries from inbound to<br />

outbound.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

TIA is characterized by its unique continuity.<br />

It provides maximum transparency at all levels<br />

with reduced interfacing requirements – covering<br />

the field level, production control level, up to the<br />

corporate management level. With TIA you also<br />

profit throughout the complete life cycle of your<br />

plant – starting with the initial planning steps<br />

through operation up to modernization, where<br />

we offer a high measure of investment security resulting<br />

from continuity in the further development<br />

of our products and from reducing the number of<br />

interfaces to a minimum.<br />

The unique continuity is already a defined<br />

characteristic at the development stage of<br />

our products and systems.<br />

The result: maximum interoperability – covering<br />

the controller, operator control and monitoring,<br />

drives, up to the process control system. This<br />

reduces the complexity of the automation solution<br />

in your plant. You will experience this, for example,<br />

in the engineering phase of the automation solution<br />

in the form of reduced time requirements and<br />

cost, or during operation using the continuous<br />

diagnostic facilities of Totally Integrated Automation<br />

for increasing the availability of your plant.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

1/5


1/6<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Integrated power distribution<br />

from one source.<br />

Totally Integrated Power.<br />

© <strong>Siemens</strong> AG <strong>2011</strong>


Communication<br />

Industrial Ethernet<br />

Process/industrial automation<br />

Products and systems<br />

Planning and dimensioning<br />

Electrical power distribution requires<br />

integrated solutions. Our answer:<br />

Totally Integrated Power (TIP). This<br />

includes tools and support for planning<br />

and configuration and a complete, optimally<br />

harmonized product and system<br />

portfolio for integrated power distribution<br />

from medium-voltage switchgear<br />

right to socket outlets.<br />

IEC 61850<br />

PROFIBUS<br />

Mediumvoltage<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Transformer<br />

PROFINET<br />

Lowvoltage<br />

BACnet<br />

KNXnet/IP<br />

Installation<br />

technology<br />

SIMARIS project SIMARIS design SIMARIS curves<br />

The power distribution products and<br />

systems can be interfaced to building<br />

or industrial automation systems<br />

(as part of Total Building Solutions or<br />

Totally Integrated Automation) via communication<br />

capable circuit breakers and<br />

modules, allowing the full potential for<br />

optimization that an integrated solution<br />

offers to be exploited throughout the<br />

product cycle – from planning right<br />

through to installation and operation.<br />

KNX<br />

Building<br />

automation<br />

Thanks to a comprehensive energy<br />

management system, power flows<br />

can be made transparent and the<br />

energy consumption of individual<br />

loads can be calculated and allocated.<br />

Building operators can thus identify<br />

power-intensive loads and implement<br />

effective optimization measures.<br />

With its products and systems, Totally<br />

Integrated Power forms the basis for<br />

this functionality and guarantees<br />

greater cost-efficiency in industrial<br />

applications, infrastructure and<br />

buildings.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

1/7


Gain transparency and lower costs:<br />

SIMATIC HMI operator control and<br />

monitoring systems<br />

The interface between human and machine – the human<br />

machine interface or HMI for short – connects the world of<br />

automation with the individual requirements of the operator.<br />

Operator control and monitoring is about managing the<br />

process, about optimizing machine and system operation,<br />

about availability and productivity.<br />

Everything from a single source<br />

With SIMATIC HMI, <strong>Siemens</strong> Automation and Drives offers a<br />

complete range of innovative and low-cost products and<br />

systems for the multi-faceted tasks of operator control and<br />

monitoring: Ranging from operator panels and visualization<br />

software for operator control and monitoring at the machine<br />

through to SCADA systems for widely differing requirements<br />

in process visualization. For special requirements, optimally<br />

adapted products are offered such as especially rugged<br />

HMI devices with all-round protection for mounting on<br />

support arms/pedestals, or operator panels with stainless<br />

steel front for use in the food and beverages industry. Of<br />

course, individual, customer-specific requirements can also be<br />

implemented.<br />

Perfectly equipped for integration in the world of<br />

automation<br />

With their open, standardized interfaces in hardware and<br />

software, SIMATIC HMI products can be integrated at any time<br />

in the production and automation level as well as in the<br />

company management level. Connectability to almost every<br />

controller on the market as well as multiple language<br />

capability of the configuration and visualization software –<br />

including Asian ideographic languages, of course – facilitate<br />

operation worldwide.<br />

Increased production transparency through<br />

Plant Intelligence<br />

Plant Intelligence is based on the rational use of information<br />

to improve processes within the company. It is designed to<br />

lower plant costs, consolidate and improve quality, avoid<br />

wastage, utilize production facilities better and ultimately<br />

ensure greater efficiency and cost effectiveness within the<br />

company. WinCC provides the best requirements for achieving<br />

this since WinCC features an integrated Historian for acquiring<br />

important production data. Using intelligent functions and<br />

tools, these process data can be edited into information<br />

necessary for making decisions and can be made available<br />

throughout the company whenever and wherever it is<br />

required – for operators as well as production managers or<br />

anyone else within the company. Even the WinCC basic<br />

system provides a wealth of display and evaluation functions,<br />

such as the statistics function for the message and measured<br />

value logs. WinCC options for IT & business integration make<br />

1/8<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

additional "smart" tools available for optimizing production<br />

using Plant Intelligence.<br />

Integrated into the World Wide Web<br />

SIMATIC HMI makes the Internet into a control desk - within a<br />

plant as well as in the worldwide network. Using the<br />

WinCC/Web Navigator, you can monitor and operate plants<br />

over the Internet or over the internal corporate intranet. Thin<br />

Client solutions can be used to integrate rugged, local devices<br />

which simultaneously establish the connection between the<br />

automation level and the control center. And over a wireless<br />

LAN or cell phone connection, you can use mobile Thin Clients<br />

such as laptop computers, PDAs (personal digital assistants) or<br />

WebPads. In this way, process, service or management information<br />

can be made individually available to users. At the<br />

machine level, many control units support remote operation,<br />

e.g. as a link between the automation level and the control<br />

room through to service and diagnostics over the Internet.<br />

For operation and monitoring at the machine, concepts with<br />

so-called Sm@rtClients and servers facilitate plant-wide<br />

access to variables and graphics, distributed operator stations<br />

as well as remote operation and diagnostics via the Internet –<br />

also in conjunction with SIMATIC Panels.<br />

Traceability and simple validation<br />

SIMATIC HMI software with "FDA options" provides a high<br />

degree of support to machine and plant manufacturers who<br />

must fulfill high quality requirements, both with respect to the<br />

products to be manufactured as well as to the manufacturing<br />

processes themselves. These options simplify plant validation<br />

enormously and thus provide the most convincing and<br />

comprehensive solution for the requirements of these sectors.<br />

They support the user in fulfilling high quality requirements<br />

asp specified by the FDA (Food and Drug Administration)<br />

21 CFR Part 11 for the food, beverages and pharmaceutical<br />

industries.<br />

Increased plant availability<br />

All operator panels and Panel <strong>PC</strong>s are designed for harsh<br />

industrial use. Redundant process visualization systems<br />

ensure a high degree of plant availability during normal<br />

operation.


Distributed operator control concepts<br />

SIMATIC HMI offers different solutions for different requirements<br />

for operator control of large machines and plants<br />

spread over extensive areas.<br />

Thus, the Sm@rtAccess option of the SIMATIC WinCC flexible<br />

visualization software, for example, allows HMI devices such<br />

as panels, Thin Clients and <strong>PC</strong>s plant-wide access via<br />

PROFINET/Ethernet to current process values and the local<br />

screen images of all involved stations.<br />

SIMATIC HMI software offers appropriate options for<br />

diagnostics, maintenance and telecontrol over the Internet<br />

from local operator stations.<br />

As remote operator stations, SIMATIC Thin Clients make the<br />

functionality of machine-level panels available in the control<br />

room or in the office, thanks to their connection to<br />

PROFINET/Ethernet, and in the other direction, they bring<br />

SIMATIC WinCC or office or IT functionality straight to the<br />

machine.<br />

In <strong>PC</strong>-based applications, the computing unit and the<br />

operating unit of a Panel <strong>PC</strong> 677B can be separated from each<br />

other by up to 30 m. When using <strong>PC</strong>s such as the SIMATIC Rack<br />

or Box <strong>PC</strong>, a SIMATIC Flat Panel monitor can also assume the<br />

function of the operating unit at a distance of up to 30 m.<br />

More than just operator control and monitoring<br />

The Multi Panels under Windows CE combine the advantages<br />

of two worlds: On the one hand, the ruggedness of an<br />

operator panel and on the other hand the flexibility typical of<br />

a <strong>PC</strong>. Apart from classical operator control and monitoring,<br />

other automation functions such as control functions can<br />

execute simultaneously. And for <strong>PC</strong>-based automation, the<br />

SIMATIC Panel <strong>PC</strong>s are available as a compact automation<br />

platform - the embedded versions being especially compact<br />

and rugged as well as maintenance-free.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

All the advantages of Totally Integrated Automation<br />

With Totally Integrated Automation (TIA), <strong>Siemens</strong> is the only<br />

supplier who offers a system-wide, integrated product and<br />

system range for automating the complete production<br />

workflow. The distinguishing feature of TIA is that it is<br />

completely integrated. The reduced number of interfaces<br />

results in very clear structures. This reduces time and costs<br />

required for engineering the automation solution and<br />

increases the availability of the plant.<br />

In conjunction with other SIMATIC components, SIMATIC HMI<br />

also supports system diagnostics and process diagnostics<br />

during normal operation. You can start <strong>ST</strong>EP 7 diagnostics<br />

directly from WinCC for comprehensive error diagnostics from<br />

the circuit diagram through to the PLC program. The SIMATIC<br />

Maintenance Station visualizes the maintenance information<br />

for the automation technology of a system – from the<br />

controller and network components to switchgear, protective<br />

equipment and control devices and the drives. This gives a<br />

clear overview of the status of the automation at any time.<br />

A competent partner for automation solutions<br />

With SIMATIC HMI, you not only get excellent products to suit<br />

your requirements, we will also support you with selecting a<br />

partner for your automation solution. In our worldwide<br />

network of <strong>Siemens</strong> Automation Solution Partners, you will<br />

find competent contact partners in your area who are always<br />

up-to-date with SIMATIC HMI technology. The <strong>Siemens</strong>internal<br />

WinCC Competence Centers implement technologyspecific<br />

products as well as customer and sector-specific<br />

solutions on the basis of WinCC. WinCC specialists are external<br />

system integrators who combine their WinCC expertise with<br />

their sector and technology know-how to create tailor-made,<br />

cost-effective solutions. Numerous products from our<br />

partners that perfectly interact with WinCC are available as<br />

WinCC Add-ons.<br />

Investment protection is included<br />

Our many years of experience in the automation engineering<br />

sector are to your advantage. The same applies to our global<br />

service network with its expert support. Further services, such<br />

as a software update service, training, ordering over the<br />

Internet, etc. round off what we have to offer.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

1/9


SIMATIC HMI<br />

A whole world of operator control and<br />

monitoring<br />

Operator panels<br />

SIMATIC Key Panels<br />

Operator panels with bus capability for easy and direct<br />

operation of machines.<br />

SIMATIC Basic Panels<br />

Operator panels with basic functionality for small machines<br />

and plants.<br />

SIMATIC Comfort Panels<br />

Operator control units with high-end functionality for<br />

demanding applications.<br />

SIMATIC Mobile Panels<br />

Mobile operator panels with or without cables for direct<br />

operator control of the plant and machine from any location.<br />

SIMATIC Micro Panels<br />

Operator panels for small machines and specially designed for<br />

SIMATIC S7-200.<br />

SIMATIC Panels<br />

Compact and rugged operator panels for use directly at the<br />

machine – finely graded in performance and convenience and<br />

available as Operator Panels and Touch Panels.<br />

SIMATIC Multi Panels<br />

Multifunctional platforms that, in addition to visualization,<br />

also perform other automation tasks such as controlling.<br />

SIMATIC WinAC MP<br />

The software PLC can be used on the Multi Panels of the<br />

170/270 and 370 series and is suitable for complex processes<br />

in which control and visualization tasks are to be solved with<br />

one and the same device.<br />

Fully enclosed HMI devices for SIMATIC<br />

The fully enclosed SIMATIC HMI devices (MP 377 PRO, Thin<br />

Client PRO, Flat Panel PRO, and HMI I<strong>PC</strong>477C PRO) are<br />

specially designed for mounting on a support arm/stand.<br />

Thanks to their extremely rugged design, the devices are ideal<br />

for industrial applications in harsh environments.<br />

Devices with stainless steel fronts<br />

Panels and Panel <strong>PC</strong>s with touch screens and stainless steel<br />

fronts have been designed for use in the food, beverage and<br />

tobacco industry for operator control and monitoring directly<br />

on food processing machines.<br />

1/10<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Process<br />

visualization<br />

Operator control<br />

and monitoring<br />

directly at the<br />

machine<br />

Single-user <strong>PC</strong><br />

HMI devices for hazardous areas<br />

Key Panels Basic Panels Comfort Panels<br />

SIMOTION<br />

Motion Control<br />

Actuators / Sensors<br />

Die SIMATIC HMI Ex devices are intrinsically safe Panel <strong>PC</strong>s and<br />

Thin Clients that have been specially designed for hazardous<br />

areas.


Client/Server<br />

Mobile Panels Micro Panels Panels Multi Panels Panel <strong>PC</strong>s<br />

Flat Panel monitors<br />

Thin Clients<br />

HMI software<br />

Manufacturing Execution Systems (MES)<br />

SIMATIC Controller<br />

S7-200<br />

Enterprise Resource Planning (ERP)<br />

Field devices<br />

Plant Intelligence<br />

S7-300<br />

Internet client<br />

S7-400<br />

Flexibility in any HMI application –<br />

from Basic Panels through to process visualization<br />

SIMATIC WinCC in the Totally Integrated Automation Portal<br />

(TIA Portal) is part of a new, integrated engineering<br />

framework which offers a uniform engineering environment<br />

for programming and configuration of control, visualization<br />

and drive solutions.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SCADA system WinCC<br />

Software HMI<br />

WinCC (TIA Portal)<br />

Additional automation systems<br />

Drives<br />

With WinCC in the TIA Portal it is possible to configure HMI<br />

applications ranging from very simple operating solutions<br />

with Basic Panels and Comfort Panels up to SCADA applications<br />

on <strong>PC</strong>-based multi-user systems. The possible range of<br />

solutions is thus greatly extended compared to the predecessor<br />

product SIMATIC WinCC flexible. SIMATIC WinCC V7<br />

remains available for extremely complex applications<br />

featuring Plant Intelligence solutions, integrated archive<br />

servers or redundant architectures, whereas WinCC Open<br />

Architecture addresses applications with demanding customization<br />

requirements, also on non-Windows platforms.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00365<br />

1/11


SIMATIC <strong>PC</strong>-based Automation<br />

SIMATIC S7<br />

SIMATIC HMI Panel<br />

Operator control and<br />

monitoring<br />

Industrial <strong>PC</strong><br />

The optimum <strong>PC</strong> hardware platforms for <strong>PC</strong>-based<br />

Automation from <strong>Siemens</strong> are our reliable and innovative<br />

industrial <strong>PC</strong>s.<br />

<strong>PC</strong>-based Controllers<br />

<strong>Siemens</strong> has developed a wide range of coordinated hardware<br />

and software components for <strong>PC</strong>-based automation. Focal<br />

point: SIMATIC <strong>PC</strong>-based Control with SIMATIC WinAC, the<br />

open, flexible and reliable controller for your <strong>PC</strong>-based<br />

automation solution.<br />

Embedded controller<br />

SIMATIC S7-mEC is a modular controller in S7-300 design with<br />

the latest embedded <strong>PC</strong> technology. It comprises the<br />

EC31 (CPU) and optionally available expansion modules.<br />

1/12<br />

SIMATIC<br />

Thin Client<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC Panel <strong>PC</strong> SIMATIC Rack <strong>PC</strong><br />

WinCC flexible,<br />

WinCC, WinAC<br />

Software PLC<br />

WinAC (F)<br />

Software PLC<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC Field PG<br />

Configuration<br />

Programming<br />

<strong>ST</strong>EP 7<br />

SIMATIC Box <strong>PC</strong><br />

Microbox <strong>PC</strong><br />

WinAC (F)<br />

Software PLC<br />

SIMATIC WinCC<br />

Visualization<br />

Archive<br />

Databases<br />

ET 200 SIMOTION D / SINAMICS / MICROMA<strong>ST</strong>ER<br />

Embedded bundles and software packages<br />

for industrial <strong>PC</strong>s<br />

Embedded bundles based on the embedded industrial <strong>PC</strong>s are<br />

extremely compact, powerful and rugged systems for use at<br />

the machine level. The functions of <strong>PC</strong>-based Control (also<br />

fail-safe) and/or visualization are already pre-installed and<br />

ready to use.<br />

Software packages for SIMATIC I<strong>PC</strong><br />

For a number of SIMATIC I<strong>PC</strong>s, low-cost software packages<br />

with the visualization software SIMATIC WinCC, WinCC flexible<br />

or the software controller SIMATIC WinAC RTX (F) are offered.<br />

An industrial <strong>PC</strong> must be purchased at the same time as the<br />

software package to take advantage of these offers.<br />

Industrial monitors and Thin Clients<br />

PROFINET<br />

Industrial Ethernet<br />

Embedded bundles:<br />

I<strong>PC</strong>427C bundles<br />

I<strong>PC</strong>477C bundles<br />

S7-modular Embedded Controller<br />

PROFINET<br />

PROFIBUS<br />

Flexible operating concepts can be implemented via Flat Panel<br />

monitors and Thin Clients. These can be industry-standard<br />

LCD monitors with high-luminance displays that can be placed<br />

up to 30 m away from the <strong>PC</strong>, or low-cost, rugged Thin Clients<br />

that offer HMI functionality over the network in large-scale,<br />

widely distributed plants.<br />

G_<strong>ST</strong>70_XX_00169


Application examples<br />

Unit-type cogeneration unit<br />

When redesigning unit-type<br />

cogeneration units, the<br />

automation approach should<br />

also be restructured. The<br />

objective was to execute all<br />

control, visualization and<br />

archiving tasks which were<br />

previously handled by a PLC<br />

and a <strong>PC</strong> on a compact unit.<br />

Space was to be saved in the<br />

control cabinet, and the<br />

administration and training requirements reduced. At the<br />

same time a rugged, maintenance-free device was required<br />

which can also be easily connected over the Internet.<br />

The advantages of the solution with SIMATIC <strong>PC</strong>-based<br />

automation:<br />

• Microbox <strong>PC</strong> I<strong>PC</strong>427C as a rugged, compact embedded<br />

system<br />

– Control, visualization and archiving of the process<br />

parameters in one device<br />

– Space and cost savings thanks to the integration of<br />

several tasks on a single embedded industrial <strong>PC</strong><br />

Previously: one PLC and one visualization <strong>PC</strong><br />

• Easy and quick access to the embedded I<strong>PC</strong> over the<br />

Internet<br />

<br />

<br />

Embedded I<strong>PC</strong><br />

Microbox <strong>PC</strong><br />

427<br />

2 x ET 200S<br />

DI/DO<br />

The plant concept<br />

Router<br />

Internet/<br />

telephone network<br />

E-mail<br />

Remote control<br />

station<br />

2 x ET 200S with<br />

motor starter<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00430<br />

Measurement of foil thickness<br />

underneath the foil.<br />

During the manufacture of<br />

plastic films, a highly accurate<br />

and uniform foil thickness<br />

over the entire width is a<br />

decisive quality criterion. For<br />

this purpose, a measuring<br />

head with radioactive source<br />

moves back and forth above<br />

the film and perpendicular to<br />

the continuously transported<br />

reel, and a sensor moves<br />

From the attenuation of the radiation, the foil thickness can be<br />

determined exactly at each position by extensive mathematical<br />

calculations, and deviations from the reference<br />

thickness can be compensated.<br />

The advantages of the solution with SIMATIC <strong>PC</strong>-based<br />

automation:<br />

• Visualization is performed using WinCC, and control using<br />

WinAC RTX on a <strong>PC</strong>.<br />

• Complex mathematical algorithms are required for evaluation<br />

of the extensive measured data.<br />

• These are meaningfully implemented in the high-level<br />

language C++. Seamless and high-performance integration<br />

of these algorithms into the <strong>ST</strong>EP 7 program is via the<br />

ODK (Open Development Kit).<br />

• Data exchange between WinAC RTX and WinCC, for visualization<br />

of extensive measured curves, takes place very<br />

quickly via the hard drive cache. This functionality was also<br />

implemented via the ODK.<br />

• Interconnection of the standardized technology function is<br />

via CFC (Continuous Function Chart).<br />

WinCC WinAC RTX<br />

The plant concept<br />

PROFIBUS<br />

CP 5613 A2<br />

SIMATIC HMI I<strong>PC</strong>577<br />

ET 200M<br />

Drive<br />

Visual C++<br />

Analysis of the<br />

measured data<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00431<br />

1/13


Application examples<br />

<strong>PC</strong>-based control of paint shops for plastic automotive<br />

parts<br />

1/14<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

For reasons of quality<br />

assurance and product<br />

liability, paint shop manufacturers<br />

are obliged to use a<br />

host computer for archiving<br />

the process data of a paint<br />

shop for flat parts, but this<br />

quickly developed into a <strong>PC</strong>based<br />

automation system<br />

with control tasks.<br />

The advantages of the solution with SIMATIC <strong>PC</strong>-based<br />

automation:<br />

• Performance of the SIMATIC WinAC <strong>PC</strong>-based control<br />

• Coupling to Linux servers through an Industrial Ethernet<br />

fiber-optic network<br />

• Open and flexible for expansions<br />

• Possibility of integration into the existing automation<br />

concept<br />

• Archiving and backup of process data as well as production<br />

data acquisition<br />

I<strong>PC</strong>847<br />

WinAC RTX<br />

WinCC flexible<br />

ET 200M<br />

Frequency<br />

converter<br />

The plant concept<br />

FOC Ethernet<br />

HMI<br />

Panel<br />

S7-314<br />

HMI Panel<br />

HMI Panel<br />

TP 177<br />

Linux<br />

Server<br />

PROFIBUS DP<br />

S7-314<br />

MPI DP<br />

VS 710<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00432<br />

Innovative <strong>PC</strong>-based solution with safety for solar panel<br />

production<br />

For a new plant for the<br />

production of solar panels,<br />

the existing highly heterogeneous<br />

concept is to be<br />

replaced by a new, state-ofthe-art<br />

automation solution<br />

which can cover comprehensive<br />

demands in a<br />

compact and integrated way.<br />

There are increased performance<br />

and memory requirements due to the increased<br />

complexity of the system. The PLC should also be able to<br />

provide the specified safety functions (emergency stop,<br />

access protection to hazardous areas).<br />

Various bus systems must be linked in plant 3. Also a<br />

customer-specific Windows application is to be used on the<br />

selected systems and therefore the connection to a higherlevel<br />

MES system has to be implemented.<br />

The system is designed for high throughput and three-shift<br />

operation.<br />

The advantages of the solution with SIMATIC <strong>PC</strong>-based<br />

automation:<br />

• Very high performance and available memory with the<br />

SIMATIC Modular Embedded Controller EC31-RTX F. In the<br />

RTX F version (worldwide the first software PLC with safety<br />

functionality), the EC31 offers full coverage of all safety<br />

requirements in the plant. This system is integrated<br />

seamlessly in Totally Integrated Automation and enables<br />

effective, plant-wide engineering.<br />

• Thanks to its openness (Open Development Kit),<br />

WinAC RTX on the host SCADA industrial <strong>PC</strong> offers the<br />

possibility for integrating a Windows customer application<br />

with very little effort, and is thus used as a data concentrator<br />

(process quality/diagnostics data), and communication<br />

with the host MES system is also implemented in<br />

combination with WinCC (SCADA).<br />

• Industry-standard products from the SIMATIC range offer<br />

maximum quality for 24/7 "round-the-clock" operation.


Safe transfer at sea<br />

For transferring persons at sea<br />

to wind energy plants or oil<br />

platforms, a Dutch company<br />

has developed a six-legged<br />

platform on hydraulic<br />

cylinders.<br />

This platform is basically an<br />

upside-down flight simulator,<br />

and allows safe transfer from<br />

a ship even in bad weather.<br />

A SIMATIC S7 modular embedded controller (S7-mEC) with<br />

fast I/O cards measures the movements of the ship and<br />

controls the extending or retracting of the cylinders so that all<br />

movements are compensated.<br />

The advantages of the solution with SIMATIC <strong>PC</strong>-based<br />

Automation:<br />

• Fault-tolerant SIMATIC S7-400H in redundant design for<br />

general control tasks<br />

• Two lower-level SIMATIC S7 modular embedded controllers<br />

which meet the requirements for high speeds, integration<br />

of fast I/O cards, and a flexible, modular and rugged design<br />

• An integrated programming environment with<br />

SIMATIC <strong>ST</strong>EP 7<br />

• Automation products from <strong>Siemens</strong> comply with the<br />

stringent requirements of the offshore sector<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based machine data acquisition optimizes the<br />

production of farming machinery<br />

To introduce more efficient,<br />

resource-saving and therefore<br />

cost-effective production<br />

processes in the factory, a<br />

leading farming machinery<br />

manufacturer has integrated<br />

a central, plant-wide machine<br />

data acquisition system using<br />

Panel <strong>PC</strong>s. Due to the need for<br />

retrofitting in the existing<br />

environment, flexible and<br />

space-saving installation of the Panel <strong>PC</strong>s was paramount.<br />

More than 200 fully enclosed SIMATIC HMI I<strong>PC</strong>477C PRO<br />

Panel <strong>PC</strong>s for central machine data acquisition with communication<br />

interfacing to the production machines and the<br />

production planning computer. Mounting of the Panel <strong>PC</strong>s<br />

directly at the machine without additional control boxes on<br />

stand-alone columns.<br />

The advantages of the solution with SIMATIC <strong>PC</strong>-based<br />

Automation:<br />

• Enhanced efficiency by optimizing the complete<br />

production organization through a high degree of<br />

uniformity<br />

• Minimized use of resources (less paper is required in<br />

production)<br />

• Simple, low-cost retrofitting of the Panel <strong>PC</strong> directly in<br />

production on a stand, without the installation of an<br />

additional operator console<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

1/15


Application examples<br />

<strong>PC</strong>-based control in automotive test rigs<br />

1/16<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Test rigs in the automotive<br />

industry require trouble-free<br />

operation and high quality.<br />

A high-performance system is<br />

required in the control,<br />

processing, archiving and<br />

visualization of measured<br />

data which can also provide<br />

openness and flexibility for<br />

connection to different bus<br />

systems and for the use of software.<br />

The advantages of the solution with SIMATIC <strong>PC</strong>-based<br />

Automation:<br />

• Flexible, easy-to-service and maintenance-friendly system<br />

with Windows XP Embedded in conjunction with<br />

SIMATIC WinAC<br />

• Reduction in integration overhead thanks to integral interfaces<br />

such as PROFIBUS, Ethernet, CAN, and the flexibility<br />

when using modules for different bus systems, e.g. <strong>PC</strong>/104<br />

• System availability concept ensures round-the-clock<br />

operation and reduced downtime costs<br />

• Fan-free, temperature-resistant operation up to 50 °C saves<br />

additional cooling measures<br />

• High investment security through long-term availability of<br />

the components<br />

Label printer<br />

The plant concept<br />

USB<br />

Distributed<br />

I/O devices<br />

Sensors<br />

Touch panel<br />

RS232<br />

Microbox<br />

<strong>PC</strong> I<strong>PC</strong>427<br />

Industrial Ethernet CAN-Bus<br />

PROFIBUS DP<br />

Barcode<br />

reader<br />

Vehicle<br />

control unit<br />

Distributed<br />

I/O devices<br />

Sensors<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00433<br />

<strong>PC</strong>-based control in the semiconductor industry<br />

production data.<br />

In the semiconductor<br />

industry, high quality and<br />

fault-free operation roundthe-clock<br />

are decisive criteria.<br />

A high-performance system<br />

that guarantees fast and<br />

precise production of the<br />

semiconductors is required for<br />

controlling the machines,<br />

monitoring the production<br />

system, and processing the<br />

High flexibility and openness are also required for connecting<br />

to the production control system and machine engineering<br />

system.<br />

The advantages of the solution with SIMATIC <strong>PC</strong>-based<br />

automation:<br />

• Compact, rugged industrial <strong>PC</strong>s with powerful processors<br />

and the latest technology enable high processing performance<br />

• Pre-installed systems save time and costs when integrated<br />

into the overall system<br />

• WinCC ToolLink-EDA (equipment data acquisition) enables<br />

diagnostics of process and machine data in real time<br />

• System availability concept with integrated RAID1<br />

functionality and remote monitoring with SIMATIC <strong>PC</strong><br />

DiagMonitor ensures fault-free 24-hour operation<br />

• High investment security through long-term availability of<br />

the components<br />

• International certification and worldwide support<br />

guarantee global use<br />

Touchpanel<br />

Machine<br />

control<br />

Visualization<br />

The plant concept<br />

Industrial Ethernet<br />

SIMATIC<br />

I<strong>PC</strong>627<br />

Industrial Ethernet<br />

HMI<br />

Panel<br />

HUB<br />

Measuring and<br />

control<br />

instruments<br />

Sensors<br />

Host<br />

SIMATIC<br />

I<strong>PC</strong>627<br />

Port to<br />

engineering<br />

system<br />

G_<strong>ST</strong><strong>80</strong>_XX_00434


Track & trace line controller for tobacco industry<br />

In order to comply with new<br />

legal regulations, a track &<br />

trace system in an existing<br />

plant has been extended. The<br />

requirement is to test<br />

100 cartons per minute in<br />

three-shift operation and to<br />

save the data in an SQL<br />

database for traceability<br />

reasons.<br />

The automation system should be characterized by high<br />

ruggedness, but also offer the openness required to connect<br />

additional components such as printers and the Machine<br />

Vision system.<br />

The advantages of the solution with SIMATIC <strong>PC</strong>-based<br />

Automation:<br />

• Compact automation solution consisting of embedded<br />

industrial <strong>PC</strong> Microbox <strong>PC</strong> I<strong>PC</strong>427, PLC with preinstalled and<br />

ready-to-use software PLC WinAC RTX, and visualization<br />

with WinCC flexible<br />

• Control of the entire track & trace system and interfacing to<br />

the control system<br />

• Open solution with the help of the WinAC ODK (Open<br />

Development Kit) thanks to a link to an SQL database for<br />

managing serial numbers and other data<br />

• Additional openness and flexibility by connecting printers<br />

and vision system<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Retrofit of a woodworking machine – safe!<br />

In the past, machines and<br />

plants for wood-working were<br />

equipped with specially<br />

developed, proprietary<br />

controllers. Today, futureoriented<br />

standard components<br />

are used for retrofit<br />

projects. The customer<br />

decided in favor of integrating<br />

standard automation and<br />

safety technology in a single<br />

unit with the SIMATIC WinAC RTX F software controller in a<br />

fan-free and maintenance-free I<strong>PC</strong>, the SIMATIC I<strong>PC</strong>427C<br />

Microbox <strong>PC</strong>. PROFINET as an innovative fieldbus connects<br />

distributed I/O, safety and operator panels quickly and easily.<br />

The advantages of the solution with SIMATIC <strong>PC</strong>-based<br />

Automation:<br />

• The compact <strong>PC</strong>-based automation solution multiplies the<br />

performance and precision of the plant.<br />

• Implementation of PROFINET resulted in a series of<br />

additional advantages such as the diagnostics capability.<br />

• Integration of standard and fail-safe automation in a single<br />

unit achieved component savings. The size of the cabinet<br />

was reduced by 20 percent and the wiring by 50 percent.<br />

The customer benefited from a high level of operating<br />

convenience and minimized machine downtimes.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

1/17


Application examples<br />

Image processing with data backup<br />

In image processing applications, high performance<br />

computers are required due to the large volume of data to be<br />

processed. The image data must be recorded, processed and<br />

saved quickly. Frame grabber cards with a high data<br />

throughput, for example, are used for recording image data.<br />

The interfaces for the expansion cards must not become<br />

bottle-necks in this case.<br />

To ensure continued problem-free processing of the acquired<br />

data, you need a state-of-the-art system with up-to-date<br />

processor and memory technology. Lots of data is produced<br />

again during the subsequent data backup. Thus the available<br />

storage medium must be fast and fail-safe at the same time.<br />

An open system is required for connecting to existing plants.<br />

The advantages of the solution with SIMATIC <strong>PC</strong>-based<br />

Automation:<br />

• Rugged SIMATIC <strong>PC</strong> with state-of-the-art processor performance<br />

and the latest technology<br />

• Current interfaces such as <strong>PC</strong>I Express for applications with<br />

a high data throughput rate, e.g. frame grabber cards for<br />

recording image data<br />

• Visualization on up to two monitors with an optional, highperformance<br />

graphic card<br />

• Onboard communication interfaces such as Ethernet and<br />

PROFINET, e.g. for connecting to EPS systems or integration<br />

in existing systems<br />

• International certifications and global support facilitate the<br />

worldwide use of the image processing solution<br />

1/18<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Control room Server room<br />

Flat Panel<br />

Machine-level<br />

The plant concept<br />

Rack <strong>PC</strong> I<strong>PC</strong>547<br />

for visualization and<br />

intermediate storage<br />

of data<br />

Rack <strong>PC</strong> I<strong>PC</strong>847 with<br />

<strong>PC</strong>Ie frame grabber cards<br />

.<br />

Rack <strong>PC</strong><br />

I<strong>PC</strong>547 –<br />

Server for data<br />

management<br />

Industrial Ethernet<br />

Camera<br />

G_<strong>ST</strong><strong>80</strong>_XX_00436


High-performance industrial <strong>PC</strong> for reliable control and<br />

monitoring of wind power plants<br />

All <strong>Siemens</strong> turbines for offshore wind power plants feature<br />

special technical characteristics that ensure long-term, lowmaintenance<br />

operation. In contrast to sites on land, offshore<br />

wind farms are not always accessible to service teams. The<br />

basic quality requirements and standards for all components<br />

used in terms of absolute fail-safety and reliability, are<br />

therefore extremely high.<br />

The SIMATIC Box <strong>PC</strong> of the 627 series that has been implemented<br />

matches the requirements of the solution provider all<br />

the way down the line. The rugged industrial <strong>PC</strong> is designed<br />

for 24-hour continuous duty at ambient temperatures up to<br />

55 °C. For reliable operation, the Box <strong>PC</strong> is installed in a solid<br />

metal housing that is resistant to shock and vibration and that<br />

demonstrates a high degree of of electromagnetic compatibility<br />

(EMC). For a high level of data security, the option of a<br />

mirror disk system with two hard disks (RAID1) was selected.<br />

The RAID1 controller is already onboard, and does not occupy<br />

a <strong>PC</strong>I slot.<br />

The rugged, reliable hardware with extremely compact<br />

dimensions in durable industrial design also stands up to the<br />

demands of continuous operation in a harsh environment.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

The advantages of the solution with SIMATIC <strong>PC</strong>-based<br />

automation:<br />

• The mounting dimensions of Box <strong>PC</strong>s remain identical over<br />

several device generations and mounting solutions can be<br />

simply reused for the next generation.<br />

• Furthermore, when a new device generation is used, any<br />

front-accessible interfaces and function elements can be<br />

retained. For example, the <strong>Siemens</strong> Wind division already<br />

utilized a complete lifecycle of a Box <strong>PC</strong> generation and no<br />

adjustments to a new hardware platform were required<br />

when the successor product was introduced.<br />

• Through compliance with international standards, such as<br />

CE and UL, and worldwide service, the Box <strong>PC</strong> can be implemented<br />

round the globe.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

1/19


Much more<br />

than a catalog.<br />

The Industry Mall.<br />

You have a catalog in your hands that will serve<br />

you well for selecting and ordering your products.<br />

But have you heard of the electronic online catalog<br />

(the Industry Mall) and all its benefits? Take a<br />

look around it sometime:<br />

www.siemens.com/industrymall<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Selecting<br />

Find your products in the structure tree, in the new "Bread-crumb"<br />

navigation or with the integral search machine with expert functions.<br />

Electronic configurators are also integrated into the Mall. Enter the<br />

various characteristic values and the appropriate product will be displayed<br />

with the relevant order numbers. You can save configurations,<br />

load them and reset them to their initial status.<br />

Ordering<br />

You can load the products that you have selected in this way into the<br />

shopping basket at a click of the mouse. You can create your own templates<br />

and you will be informed about the availability of the products<br />

in your shopping cart. You can load the completed parts lists directly<br />

into Excel or Word.<br />

Delivery status<br />

When you have sent the order, you will receive a short e-mail confirmation<br />

which you can print out or save. With a click on "Carrier", you<br />

will be directly connected to the website of the carrier where you can<br />

easily track the delivery status.<br />

Added value due to additional information<br />

So you have found your product and want more information about it?<br />

In just a few clicks of the mouse, you will arrive at the image data base,<br />

manuals and operating instructions. Create your own user documentation<br />

with My Documentation Manager.<br />

Also available are FAQs, software downloads, certificates and<br />

technical data sheets as well as our training programs. In the image<br />

database you will find, depending on the product, 2D/3D graphics,<br />

dimension drawings and exploded drawings, characteristic curves or<br />

circuit diagrams which you can download.<br />

Convinced? We look forward to your visit!


2/2 Introduction<br />

2/9 Key Panels<br />

2/9 SIMATIC HMI KP8/KP8F<br />

2/12 SIMATIC PP7<br />

2/15 SIMATIC PP17<br />

2/19 SIPLUS Push Button Panels<br />

2/19 SIPLUS PP17<br />

2/20 Basic Panels<br />

2/20 Basic Panels – Standard<br />

2/32 SIPLUS Basic Panels<br />

2/34 Comfort Panels<br />

2/34 Comfort Panels – Standard<br />

2/47 Mobile Panels<br />

2/51 SIMATIC Mobile Panel 177<br />

2/61 SIMATIC Mobile Panel 277<br />

2/69 SIMATIC Mobile Panel 277(F) IWLAN<br />

2/85 Micro Panels<br />

2/85 Text Display TD 200<br />

2/88 Text Display TD 400C<br />

2/91 SIMATIC OP 73micro<br />

2/95 SIMATIC TP 177micro<br />

2/99 SIPLUS S7-200 TD 200<br />

2/100 SIPLUS S7-200 TD 400C<br />

2/101 Panels - 70 series<br />

2/101 SIMATIC OP 73<br />

2/105 SIMATIC OP 77A<br />

2/109 SIMATIC OP 77B<br />

2/114 Panels – 170 series<br />

2/114 SIMATIC TP 177A<br />

2/119 SIMATIC TP 177B<br />

2/126 SIMATIC OP 177B<br />

2/131 Panels – 270 series<br />

2/131 SIMATIC TP 277 6"<br />

2/136 SIMATIC OP 277 6"<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

2/141 SIPLUS Panels for 70 series<br />

2/141 SIPLUS HMI OP 73<br />

2/142 SIPLUS HMI OP 77B<br />

2/143 SIPLUS Panels for 170 series<br />

2/143 SIPLUS HMI TP 177B<br />

2/144 SIPLUS HMI OP 177B<br />

2/145 SIPLUS Panels for 270 series<br />

2/145 SIPLUS HMI TP 277 6"<br />

2/146 Multi Panels – 170 series<br />

2/146 SIMATIC MP 177<br />

2/151 Multi Panels – 270 series<br />

2/151 SIMATIC MP 277<br />

2/160 Multi Panels – 370 series<br />

2/160 SIMATIC MP 377<br />

2/169 Multi Panel options<br />

2/169 SIMATIC WinAC MP<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2<br />

2/175 SIPLUS Multi Panels for 170 series<br />

2/175 SIPLUS HMI MP 177<br />

2/176 SIPLUS Multi Panels for 270 series<br />

2/176 SIPLUS HMI MP 277<br />

2/177 SIPLUS Multi Panels for 370 series<br />

2/177 SIPLUS HMI MP 377<br />

2/178 System interfaces with WinCC flexible<br />

2/179 SIMATIC S7<br />

2/182 SIMATIC S5<br />

2/184 SIMATIC 505<br />

2/185 Third-party controllers<br />

2/191 System interfaces with WinCC<br />

(TIA Portal)<br />

2/192 SIMATIC S7<br />

2/194 Third-party controllers<br />

2/198 HMI Accessories<br />

2/198 Industrial USB Hub 4<br />

2/199 Connecting cables<br />

2/204 RS485 bus connector<br />

2/205 IE FC RJ45 Plug 2 x 2<br />

2/206 Accessories for SIMATIC Mobile<br />

Panels<br />

2/208 HMI Accessories<br />

2/208 Terminal boxes<br />

2/210 SIPLUS terminal boxes<br />

2/211 Charging station<br />

2/212 Transponder<br />

2/213 Memory media<br />

2/214 Converters/adapters<br />

2/215 Service packs<br />

2/217 Protective covers<br />

2/218 Cover foils<br />

2/220 Fixing elements<br />

2/221 Printers<br />

2/221 Recommended printers for operator<br />

panels


2<br />

Operator panels<br />

Introduction<br />

Introduction<br />

■ Overview<br />

■ Benefits<br />

A finely graded range of operator control and monitoring is available<br />

for local operator control and monitoring: From Key Panels,<br />

Basic Panels, through Comfort Panels and Multi Panels to Mobile<br />

Panels. HMI devices with all-round IP65/NEMA 4 protection for<br />

distributed configurations are available for applications with<br />

especially high requirements with regard to ruggedness.<br />

Rugged and compact for use at machine level<br />

With IP65/NEMA 4 degree of protection at the front, high EMC<br />

and extreme vibration resistance, the SIMATIC HMI operator<br />

panels are ideally suited for use at machine level in rough<br />

industrial environments. Thanks to their compact design with a<br />

shallow mounting depth, the stationary Operator Panels can be<br />

Key Panels<br />

fitted anywhere, even where only restricted space is available.<br />

Key Panels and Push Button Panels (PP) are the innovative alternative<br />

to conventionally wired key panels. Supplied pre-assem-<br />

For distributed configurations, there are also devices available<br />

with all-round IP65/NEMA 4 protection.<br />

bled and ready for installation, the bus-compatible operator The extremely rugged and shock-proof housing with degree of<br />

panels are the key to drastically reducing wiring times when protection IP65 makes the Mobile Panels especially suitable for<br />

compared with conventional methods.<br />

industrial applications. Their low weight and ergonomic design<br />

Basic Panels<br />

means that they are user-friendly and easy to operate.<br />

Basic Panels offer basic HMI functionality for small machines<br />

One configuration software for everything<br />

and applications. These are available in various display sizes: as SIMATIC WinCC (TIA Portal) is a tool for the uniform configura-<br />

a 3" key panel (KP), as a 4" to 12" touch screen with additional tion of all SIMATIC HMI Panels as well as <strong>PC</strong>-based systems.<br />

keys (KTP), and as a 15" touch panel (TP). Versions can be Graded versions are available for every task. The software<br />

selected for connection to PROFINET/Ethernet or<br />

permits simple and efficient configuration. Programming experi-<br />

PROFIBUS DP/MPI.<br />

ence is not required.<br />

Comfort Panels<br />

Completed configurations can be reused within the family.<br />

Comfort Panels offer high-end functionality for demanding appli- Component of Totally Integrated Automation<br />

cations. They offer high-resolution widescreen displays in sizes<br />

from 4" to 12", alternatively for touch screen operation (TP) or key<br />

operation (KP). In size 4" also with touch screen and additional<br />

keys (KTP).<br />

<strong>Siemens</strong> provides the complete modular system of matched<br />

components for automation solutions from one source and – with<br />

Totally Integrated Automation – one of the most successful automation<br />

concepts worldwide. SIMATIC WinCC (TIA Portal) is an<br />

The Comfort Panels are equipped with PROFINET/Ethernet as integral component of this world. It offers crucial advantages.<br />

well as PROFIBUS DP/MPI interfaces.<br />

Thanks to the uniformity in configuration/programming, data<br />

Mobile Panels<br />

management and communication, the engineering costs of an<br />

automation solution are significantly reduced.<br />

The portable operator panels facilitate operator control and<br />

monitoring at the actual scene of the event with direct access<br />

Open for a wide variety of automation systems<br />

and visual contact to the process. They provide simple and safe Despite the consistent incorporation into the SIMATIC world, the<br />

reconnection during operation (Mobile Panel 177 and Mobile Panels are nevertheless open for connection to PLCs from many<br />

Panel 277) or wireless freedom (Mobile Panel 277 (F) IWLAN) different vendors. The standard delivery includes a comprehen-<br />

and can therefore be used flexibly on a machine or system. sive range of user-friendly drivers.<br />

Micro Panels<br />

Innovative operator control and monitoring<br />

Designed specifically for applications with the SIMATIC S7-200 The SIMATIC HMI Panels facilitate innovative operator control<br />

micro PLC, either with text display (TD) or pixel-graphic display, and monitoring combined with ruggedness, stability and<br />

as operator panels (OP) with membrane keyboard or touch simplicity. On the Comfort Panels and Multi Panels in particular,<br />

screen (TP).<br />

standard hardware and software interfaces, e.g. the<br />

Panels<br />

MMC/SD/CF card, USB, Ethernet, PROFIBUS DP, Visual Basic<br />

scripts or customer-specific ActiveX controls, provide more<br />

Graphic Panels of the 70/170/270 series<br />

flexibility and openness to the office world.<br />

With pixel graphic display in 4" or 6" for realistic presentation of Worldwide application<br />

the processes. Either as Touch Panels (TP) with touch-sensitive<br />

display, Operator Panels (OP) with membrane keyboard, or<br />

touch/key combination on the OP 177B 6" or TP 177B 4".<br />

The SIMATIC HMI Panels are ideally equipped for global use.<br />

Online language selection permits selection of up to<br />

32 languages during operation simply by pressing a button. The<br />

Multi Panels<br />

170/270/370 series<br />

wide variety of languages available also includes, for example,<br />

Asian logographic languages (Chinese, Taiwanese, Korean,<br />

Japanese) or Russian. The configuration interface of WinCC<br />

These can be used for operator control and monitoring in the<br />

same way as the panels, by means of touch screens or<br />

membrane keyboards. In addition, the Multi Panels (MPs) permit<br />

installation of additional applications and thus allow integration<br />

of several automation tasks on a single platform with the<br />

PLC WinAC MP software, for example. The 370 series also<br />

encompasses an HMI device with all-round IP65/NEMA 4<br />

protection and 15" touch display for distributed configurations.<br />

Multi Panel option: WinAC MP<br />

The software PLC can be used in the 170/270 and 370 Multi<br />

Panels (exception: MP 370) and is ideal for complex processes<br />

in which one device must handle control and visualization tasks.<br />

(TIA Portal) including the online help and the complete documentation<br />

is also multilingual. Up to 32 languages can be used<br />

in one project. And all this is complemented by global servicing<br />

and support from <strong>Siemens</strong>.<br />

2/2<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Configuration overview<br />

Possible<br />

1) WinCC flexible 2005 or higher and TP 177B 4"<br />

with WinCC flexible 2008 and higher<br />

2)<br />

WinCC flexible 2005 SP1 and higher<br />

3) WinCC flexible 2007 and higher: Mobile Panel 277(F) IWLAN V1;<br />

WinCC flexible 2008 SP2 and higher: Mobile Panel 277(F) IWLAN V2<br />

4) WinCC flexible 2008 and higher<br />

5) WinCC flexible 2008 SP1 and higher<br />

Operator panels<br />

Introduction<br />

WinCC flexible engineering software<br />

Micro Compact Standard Advanced<br />

Basic Panels<br />

KTP400 Basic 5) 5) 5)<br />

KTP600 Basic 5) 5) 5)<br />

KTP1000 Basic 4) 4) 4)<br />

TP1500 Basic<br />

Mobile Panels<br />

4) 4) 4)<br />

Mobile Panel 177 1) 1) 1)<br />

Mobile Panel 277 2) 4) 2) 4)<br />

Mobile Panel 277 (F) IWLAN 3) 3)<br />

Micro Panels<br />

OP 73micro<br />

TP 177micro<br />

Panels – 70 series<br />

OP 73<br />

OP 77A/B<br />

Panels – 170 series<br />

TP177A<br />

TP/OP 177B 1) 1) 1)<br />

Panels – 270 series<br />

TP 277/OP 277 2) 2)<br />

Multi Panels – 170 series<br />

MP 177 5) 4) 4)<br />

Multi Panels – 270 series<br />

MP 277<br />

Multi Panels – 370 series<br />

MP 377 3) 3)<br />

WinAC MP<br />

WinAC MP177<br />

WinAC MP277<br />

WinAC MP377<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

5) 5) 5)<br />

5) 5)<br />

5) 5)<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Introduction<br />

2/3<br />

2


2<br />

Operator panels<br />

Introduction<br />

Introduction<br />

■ Configuration overview (continued)<br />

Basic Panels<br />

KP300 Basic<br />

KTP400 Basic<br />

KTP600 Basic<br />

KTP1000 Basic<br />

TP1500 Basic<br />

Comfort Panels<br />

KTP400/KP400 Comfort<br />

TP700/KP700 Comfort<br />

TP900/KP900 Comfort<br />

TP1200/KP1200 Comfort<br />

Mobile Panels<br />

Mobile Panel 177<br />

Mobile Panel 277<br />

Mobile Panel 277 (F) IWLAN<br />

Panels – 70 series<br />

OP73<br />

OP77A<br />

OP77B<br />

Panels – 170 series<br />

TP177A<br />

TP/OP 177B<br />

Panels – 270 series<br />

TP 277/OP 277<br />

Multi Panels – 170 series<br />

MP 177<br />

Multi Panels – 270 series<br />

MP 277<br />

Multi Panels – 370 series<br />

MP 377<br />

WinAC MP<br />

WinAC MP177<br />

WinAC MP277<br />

WinAC MP377<br />

Possible<br />

1) from WinCC (TIA portal) V11 SP1<br />

2/4<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

WinCC (TIA Portal) Engineering Software<br />

Basic Comfort Advanced Professional<br />

1) 1) 1)<br />

1) 1) 1)<br />

1) 1) 1)


■ Technology overview<br />

Available<br />

– Not available<br />

1) The TD 100C/200/200C/400C is configured using MicroWIN<br />

2) Only with OP 77B<br />

3) Not with TP 177A; TP/OP 177B (S5 only)<br />

4) Not with Mobile Panel 177DP<br />

5) With OP 73 and OP 77A, connection only possible to S7-200/300/400<br />

6) Only with TP/OP 177B color<br />

7) Only with Mobile Panel 177 DP/Mobile Panel 277<br />

8) Only with Mobile Panel 277/277(F) IWLAN<br />

9) Only with Mobile Panel 277(F) IWLAN<br />

10) Not with Mobile Panel 277(F) IWLAN<br />

11) Only with KTP600 Basic color DP and KTP1000 Basic color DP<br />

12) Not with KTP600 Basic color DP and KTP1000 Basic color DP<br />

13) Not with KP300 Basic<br />

14) Only available when configuring with WinCC flexible<br />

Operator panels<br />

Introduction<br />

Basic Panels Comfort Panels Mobile Panels Micro Panels<br />

KP300 Basic<br />

KTP400 Basic<br />

KTP600 Basic<br />

KTP1000 Basic<br />

TP1500 Basic<br />

Display KP300 Basic: 3.6" F<strong>ST</strong>N<br />

KTP400 Basic: 3.8" <strong>ST</strong>N<br />

KTP600 Basic: 5.7" <strong>ST</strong>N or<br />

5.7" TFT<br />

KTP1000 Basic: 10.4" TFT<br />

TP1500 Basic: 15.1" TFT<br />

Colors KP300 Basic: black/white<br />

KTP400 Basic 4 gray<br />

levels<br />

KTP600 Basic 4-level<br />

grayscale or 256 colors<br />

KTP1000 Basic 256 colors<br />

TP1500 Basic 256 colors<br />

Operator controls<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

KTP400 Comfort<br />

KP400 Comfort<br />

KP700 Comfort<br />

TP700 Comfort<br />

TP900 Comfort<br />

KP900 Comfort<br />

TP1200 Comfort<br />

KP1200 Comfort<br />

KTP400/KP400 Comfort:<br />

4.3" TFT Widescreen<br />

KP700/T700 Comfort: 7.0"<br />

TFT Widescreen<br />

TP900/KP900 Comfort:<br />

9.0" TFT Widescreen<br />

TP1200/KP1200 Comfort:<br />

12.1" TFT Widescreen<br />

Membrane keyboard only (KP300 Basic) (KP400/KP700/KP900/<br />

KP1200 Comfort)<br />

Touch screen only (TP1500 Basic) (TP700/TP900/TP1200<br />

Comfort)<br />

Membrane keyboard and Touch<br />

Interfaces/protocols<br />

(KTP400/KTP600/<br />

KTP1000 Basic)<br />

Mobile Panel 177/<br />

Mobile Panel 277/Mobile<br />

Panel 277 (F) IWLAN<br />

Mobile Panel 177: 5.7"<br />

<strong>ST</strong>N<br />

Mobile Panel 277:<br />

7.5"/10.4" TFT<br />

277(F) IWLAN: 7.5" TFT<br />

16 million colors Mobile Panel 177: 256<br />

colors<br />

Mobile Panel 277 / 277(F)<br />

IWLAN: 64k colors<br />

TD 200/<br />

TD 400C1)<br />

OP 73micro<br />

TP 177micro<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Introduction<br />

TD 200/ TD 400C: text<br />

display<br />

OP 73micro: 3" LCD<br />

TP 177micro: 5.7" <strong>ST</strong>N<br />

TD 200/TD 400C/<br />

OP 73micro: monochrome<br />

TP 177micro: 4 shades of<br />

blue<br />

– (TD200/TD400C/<br />

OP 73 micro)<br />

– (TP 177micro)<br />

(KTP400 Comfort) –<br />

Serial / MPI / PROFIBUS DP 11) / 11) / 11) / / 7) / 7) / 7) / / –<br />

USB / Ethernet / WLAN – / 12) / – / / – 8) / 4) / 9) – / – / –<br />

Multimedia card / CF Card / <strong>PC</strong><br />

card slot<br />

– / – / – / – / – / – / – – / – / –<br />

Memory<br />

KP300/KTP400<br />

KTP400/KP400 Comfort: Mobile Panel 177: TD 200/TD 400C/<br />

(available for user data)<br />

Basic/KTP600 Basic: 4 MB<br />

2048 KB<br />

OP 73micro:<br />

512 KB<br />

KP700/TP700/KP900/TP9 Mobile Panel 277/277(F) 128 KB<br />

KTP1000 Basic/TP1500 00/<br />

IWLAN: 6 MB<br />

TP 177micro: 256 KB<br />

Basic:1024 KB<br />

KP1200/TP1200Comfort:<br />

12 MB<br />

Connection to controller<br />

SIMATIC S7 / WinAC / / / 10) S7-200 only<br />

SIMATIC S5 / 505 13) / 13) – / – 10) / 10)) – / –<br />

SINUMERIK / SIMOTION 14) – / – – / – 10) / 10) – / –<br />

Third-party controllers 10) –<br />

2/5<br />

2


2<br />

Operator panels<br />

Introduction<br />

Introduction<br />

■ Configuration overview (continued)<br />

Panels Multi Panels<br />

70 series 170 series 270 series 170 series 270 series 370 series<br />

OP 73<br />

TP 177A<br />

TP/OP 277 MP 177 MP 277 MP 377<br />

OP 77A/B TP/OP 177B<br />

Display OP 73:<br />

TP 177B 4": 5.7" TFT 6" TFT 7.5"/10.4" TFT 12"/15"/19" TFT<br />

3“ LCD<br />

4.3" TFT<br />

OP 77A/B: 4.5" widescreen<br />

LCD<br />

otherwise: 5.7"<br />

<strong>ST</strong>N<br />

Colors Monochrome TP 177A:<br />

4 shades of blue<br />

TP/OP 177B:<br />

4 shades of blue/<br />

256 colors<br />

256 colors 65535 colors 65535 colors 65535 colors<br />

Operator controls<br />

Membrane keyboard (TP 177B 4" and<br />

OP 177B)<br />

Touch screen –<br />

Membrane keyboard<br />

and Touch<br />

Interfaces/protocols<br />

Serial / MPI /<br />

PROFIBUS DP<br />

Available<br />

– Not available<br />

1)<br />

The TD 100C/200/200C/400C is configured using MicroWIN<br />

2) Only with OP 77B<br />

3) Not with TP 177A; TP/OP 177B (S5 only)<br />

4) Not with Mobile Panel 177DP<br />

5) With OP 73 and OP 77A, connection only possible to S7-200/300/400<br />

6) Only with TP/OP 177B color<br />

7)<br />

Only available when configuring with WinCC flexible<br />

2/6<br />

– (TP 177B 4" and<br />

OP 177B)<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

–<br />

– – – –<br />

/ / / / / / / / / / / /<br />

USB / Ethernet / WLAN 2) / – / – / 6) / – / / – / / /<br />

Multimedia card /<br />

CF Card / <strong>PC</strong> card slot<br />

2) / – / – / 3) / – / – / – / – / – /<br />

Memory<br />

OP 73/OP 77A: TP 177A<br />

4 MB 2 MB 6 MB 12 MB<br />

(available for user data) 256 KB<br />

512 KB<br />

OP 77B<br />

TP/OP 177B:<br />

1024 KB<br />

2 MB<br />

Connection to<br />

controller<br />

SIMATIC S7 / WinAC / / / / / /<br />

SIMATIC S5 / 505 5) / 5) 3) / 3) / / / /<br />

SINUMERIK /<br />

SIMOTION 7)<br />

– / – / 3) / / / /<br />

Third-party controllers 6) 3)


Available<br />

– Not available<br />

1) Only Mobile Panel 277/277(F) IWLAN<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Introduction<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Introduction<br />

■ Functionality (configuration with WinCC V11)<br />

Basic Panels Comfort Panels Mobile Panels<br />

KP300<br />

KTP400 Comfort<br />

Mobile Panel 177/<br />

KTP400Basic<br />

KP400/700/900/<br />

Mobile Panel 277/277 (F) IWLAN<br />

KTP600Basic<br />

1200 Comfort<br />

KTP1000Basic<br />

TP1500Basic<br />

TP700/900/1200 Comfort<br />

Number<br />

200 KTP400/KP400 Comfort: 2000 Mobile Panel 177: 2000<br />

of messages<br />

All other Comfort Panels: 4000 Mobile Panel 277 / 277(F) IWLAN: 4000<br />

Alarm buffer<br />

256 KTP400/KP400 Comfort: 256<br />

Mobile Panel 177: 256<br />

(number of entries)<br />

All other Comfort Panels: 1024 Mobile Panel 277 / 277(F) IWLAN: 512<br />

Recipes 5 KTP400/KP400 Comfort: 100<br />

Mobile Panel 177: 100<br />

All other Comfort Panels: 300<br />

Mobile Panel 277 / 277(F) IWLAN: 300<br />

Process screens 50 500 500<br />

Bar graphs/curve<br />

diagrams (full graphic)<br />

/ / /<br />

Tags KP300/KTP400 Basic: 250<br />

KTP400/KP400Comfort: 1024<br />

Mobile Panel 177: 1024<br />

KTP600/1000 Basic/TP1500 Basic:<br />

500<br />

All other Comfort Panels: 2048 Mobile Panel 277 / 277(F) IWLAN: 2048<br />

Logging – 1)<br />

Visual Basic Scripts – 1)<br />

Online languages<br />

User administration<br />

(security)<br />

5 32 Mobile Panel 177: 5<br />

Mobile Panel 277/277(F) IWLAN: 16<br />

Print functions –<br />

PG functions<br />

(<strong>ST</strong>ATUS/CONTROL)<br />

with SIMATIC S5/S7<br />

– 1)<br />

2/7<br />

2


2<br />

Operator panels<br />

Introduction<br />

Introduction<br />

■ Functionality (configuration with WinCC (TIA Portal))<br />

Panels Multi Panels<br />

70 series 170 series 270 series 170 series 270 series 370 series<br />

OP 73<br />

TP 177A<br />

TP 277<br />

MP 177 MP 277 MP 377<br />

OP 77A/<br />

OP 77B<br />

TP/OP 177B OP 277<br />

Number<br />

OP 73: 500 TP 177A: 1000 4000 2000 4000 4000<br />

of messages OP 77A/<br />

OP 77B: 1000<br />

TP/OP 177B: 2000<br />

Message buffer OP 73: 150<br />

(number of entries) OP 77A/<br />

OP 77B: 256 3)<br />

TP 177A3) / TP/OP 512 256 512 1024<br />

177B: 256<br />

Recipes OP 77A: 5 TP 177A: 5<br />

OP 77B: 100<br />

4) 300 100 300 500<br />

TP/OP 177B: 100<br />

Process screens 500 TP 177A: 250<br />

TP/OP 177B: 500<br />

500 500 500 500<br />

Bar graphs/curve<br />

diagrams<br />

(full graphic)<br />

/ – / 4) / / / /<br />

Tags 1000 TP 177A: 500<br />

TP/OP 177B: 1000<br />

2048 1000 2048 4096<br />

Logging – – –<br />

Visual Basic Scripts – – –<br />

Online languages<br />

User administration<br />

(security)<br />

5 5 16 16 16 16<br />

Print functions 2) 1)<br />

PG functions<br />

(<strong>ST</strong>ATUS/<br />

CONTROL) with<br />

SIMATIC S5/S7<br />

– 1)<br />

Available<br />

– Not available<br />

1) Except TP 177A<br />

2) Only with OP 77B<br />

3) Non-retentive<br />

4) On TP 177A from WinCC flexible 2007<br />

2/8<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Overview<br />

SIMATIC HMI Key Panel KP8 PN/KP8F PN<br />

The KP8 PN and KP8F PN Key Panels are the innovative<br />

successor to the PP7 Push Button Panel<br />

The following two versions are available:<br />

-A PROFINET version<br />

with 8 large backlit keys each<br />

-A PROFINET Failsafe version (with connection option,<br />

e. g. for an emergency stop button)<br />

with 8 large backlit keys each<br />

High flexibility in the smallest space at an extremely<br />

reasonable price<br />

On the rear, 8 I/O PINs are available as standard. These<br />

I/O PINs can be used for the connection of additional control<br />

elements.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Key Panels<br />

SIMATIC HMI KP8/KP8F<br />

■ Benefits<br />

Machine operation is rarely possible without hard-wired<br />

elements such as emergency stop units, indicator lights, or keyoperated<br />

switches. Extension units are available for the<br />

integration of such operator controls. They are mounted on the<br />

side of the PRO device. The new SIMATIC HMI Key Panels facilitate<br />

the integration of keys and indicator lights considerably.<br />

The operator controls must now no longer be individually wired.<br />

Instead, control is performed directly via PROFINET. Each<br />

extension unit of the HMI PRO devices can accommodate up to<br />

two KP8 PN or KP8F PN. Up to five colors are thus available for<br />

the direct keys. Of course, you can connect further elements<br />

such as emergency stop units 1) and key-operated switches on<br />

the rear side of the Key Panel.<br />

The combination of a SIMATIC HMI PRO device and KP8 PN,<br />

KP8F PN offers the following advantages:<br />

No control cabinet required<br />

Low cabling overhead<br />

Optimally coordinated design<br />

1) Safety version<br />

■ Application<br />

Safety<br />

With the SIMATIC HMI KP8F PN, there is also a version available<br />

for use in safety-related applications. The device also offers two<br />

safety-related inputs, and if used with one channel it achieves<br />

safety standard SIL 2, with two channels it achieves SIL 3.<br />

Depending on the safety level, one or two emergency stop<br />

switches can be connected. Through the support of PROFINET<br />

Shared Device, it can even address two controllers simultaneously.<br />

Empty front<br />

An empty front is available as accessory. It has the same look &<br />

feel as the SIMATIC HMI Key Panels and can be seamlessly and<br />

modularly added on to a KP8 PN or KP8F PN. The empty front is<br />

a purely mechanical version without electronics. It is only used<br />

for the installation of long-stroke keys or emergency stop and<br />

key-operated switches. The empty front is perforated at the rear<br />

so that up to 4 holes can be punched out for a 22.5 mm standard<br />

control element without the need for cutting tools.<br />

Use in PRO devices<br />

Both versions are the ideal supplement for the SIMATIC HMI<br />

PRO devices with full IP65 protection, because they can be<br />

installed in the associated extension units due to their<br />

customized dimensions.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/9<br />

2


2<br />

Operator panels<br />

Key Panels<br />

SIMATIC HMI KP8/KP8F<br />

■ Design<br />

SIMATIC HMI KP8 PN/KP8F PN<br />

With the SIMATIC HMI KP8 PN and KP8F PN, <strong>Siemens</strong> offers two<br />

new key operator panels with eight large, easily operable keys.<br />

The devices are supplied pre-assembled and ready for installation<br />

and thus no time-consuming individual mounting and<br />

wiring is required as for conventional operator panels.<br />

Typical fields of application for key operator panels are applications<br />

that require the deterministic transmission of operator<br />

commands. For optimum user friendliness, they offer tactile<br />

feedback when a key is pressed and they can be freely<br />

configured. In addition, the intensity and color of the LED<br />

backlighting of all keys can be adapted. The configuration of the<br />

colors (white, green, red, yellow, blue) enhances user friendliness,<br />

the alterable brightness enhances readability under<br />

difficult lighting conditions such as extreme brightness. All keys<br />

can be individually labeled and adapted to the application by<br />

means of two slide-in labels each. The connection to the control<br />

is implemented via PROFINET. An integrated 2-port PROFINET<br />

switch facilitates the configuration of a linear topology without<br />

additional modules.<br />

The KP8 PN and the KP8F PN continue to offer 8 integrated IOs<br />

at the rear, via which additional operator controls such as shortstroke<br />

keys can be connected. In contrast to individual components,<br />

no time-consuming assembly and wiring are required.<br />

2/10<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

8 large illuminated pushbuttons with good tactile feedback,<br />

which can even be operated with gloves and are therefore<br />

suitable for harsh industrial environments<br />

Simple inscribable keys using labeling strips<br />

Integrated multicolor LEDs for free color selection per key<br />

(white, green, red, yellow, blue) which indicate the state of the<br />

machine<br />

8 I/O PINs at the rear can be used as input or output<br />

2 x RJ45 with integrated switch --> no additional costs for<br />

network integration<br />

24 V DC can be looped through easily<br />

Integrated diagnostics system<br />

F version offers the option of connecting a SIL3 emergency<br />

stop unit at the rear<br />

Design of empty enclosure for easy mounting of 22.5 mm<br />

control elements<br />

PROFINET Shared Device (KP8F PN)<br />

MRP (Medium Redundancy Protocol)<br />

One or two emergency stop units (SIL level 2/3 ) can be<br />

connected to the Safety version of KP8F.<br />

Due to the integrated PROFINET switch, no conventional main<br />

switch is required and thus less hardware is required.<br />

Compatible with SIMATIC HMI PRO devices<br />

■ Technical specifications<br />

6AV3 688-3AY36-0AX0 6AV3 688-3AF37-0AX0<br />

KP8 PN KP8F PN<br />

Control elements<br />

Function keys, programmable 8 function keys 8 function keys<br />

Membrane keyboard Yes Yes<br />

Connection for mouse/keyboard/barcode reader<br />

Type of output<br />

- / - / - - / - / -<br />

Color modes for LED<br />

Ambient conditions<br />

Operating temperature<br />

5; red, green, blue, white, yellow 5; red, green, blue, white, yellow<br />

Operation (vertical installation) 0 °C to +55 °C 0 °C to +55 °C<br />

Operation (max. tilt angle)<br />

Storage/transport temperature<br />

0 °C to +45 °C 0 °C to +45 °C<br />

Transport, storage<br />

Relative humidity<br />

-20 °C to +60 °C -20 °C to +60 °C<br />

max. relative humidity 95 % 95 %<br />

maximum permissible angle of inclination without<br />

external ventilation<br />

Dimensions and weight<br />

Dimensions<br />

+/- 45 ° +/- 45 °<br />

Mounting cutout/device depth (W x H) 67 mm x 129 mm 67 mm x 129 mm<br />

■ Ordering data Order No. Order No.<br />

SIMATIC HMI Key Panel KP8 PN A 6AV3 688-3AY36-0AX0<br />

Empty front 6AV3 688-3XY38-3AX0<br />

Push Button Panel for PROFINET<br />

Empty front for KP8 and KP8F in<br />

with 8 short-stroke keys with<br />

combination with the HMI PRO<br />

multi-colored LEDs, 8 configu-<br />

devices<br />

rable DI/DO pins, 24 V DC can be<br />

looped through<br />

Connector set 12-pin<br />

for KP8 PN<br />

6AV6 671-3XY38-4AX0<br />

SIMATIC HMI Key Panel<br />

KP8F PN<br />

A 6AV3 688-3AF37-0AX0<br />

10 units per packaging unit<br />

Push Button Panel for PROFINET<br />

with PROFIsafe, 8 short-stroke<br />

Connector set 16-pin<br />

for KP8F PN<br />

6AV6 671-3XY48-4AX0<br />

keys with multi-colored LEDs,<br />

8 configurable DI/DO pins,<br />

10 units per packaging unit<br />

24 V DC can be looped through,<br />

2 safety inputs<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H


■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical specifications.<br />

98<br />

SIMATIC HMI Key Panel KP8<br />

155<br />

67.5 16.2<br />

127.7<br />

13.7<br />

38<br />

48.8<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6<br />

G_<strong>ST</strong><strong>80</strong>_XX_00442<br />

Operator panels<br />

Key Panels<br />

SIMATIC HMI KP8/KP8F<br />

■ More information<br />

Further information can be found on the Internet at:<br />

www.siemens.com/simatic-key-panels<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/11<br />

2


2<br />

Operator panels<br />

Key Panels<br />

SIMATIC PP7<br />

■ Overview<br />

SIMATIC Push Button Panels are the innovative alternative to<br />

conventional operator panels for easy and direct control of<br />

machines:<br />

Pre-fabricated and ready for operation;<br />

simply connect to the control and all buttons and lamps are<br />

ready for immediate use<br />

Connection to any type of control via a bus cable<br />

(PROFIBUS DP as "standard slave" or MPI)<br />

Fitted with short-stroke keys, additional digital inputs and slots<br />

for 22.5 mm standard components<br />

2/12<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Up to 90 % time savings: Pushbuttons, switches and lamps do<br />

not have to be fitted and wired individually<br />

Use of standard cables, for example, makes configuration and<br />

startup easier<br />

No configuration tool required<br />

Service-friendly thanks to rear display to indicate operating<br />

states and messages in plain text, without programming<br />

device<br />

Quick and easy machine operation thanks to multi-colored<br />

indicator lights<br />

User-friendly labeling option for pushbuttons and lamps using<br />

slide-in labels<br />

As the 22.5 mm standard elements can be connected directly<br />

on the panel, no additional wiring and I/O modules are<br />

required<br />

■ Application<br />

The rugged PP7 Push Button Panel is designed for simple and<br />

straightforward machine operation.<br />

It can be used wherever operator control and monitoring<br />

functions cannot be carried out without keys and lamps,<br />

e.g. on control consoles for machines and plants in the food<br />

and beverage industry where smooth fronts are necessary to<br />

facilitate cleaning. Even in special mechanical equipment<br />

manufacture, the push button panels can be used to easily set<br />

up standard operator panels that are then amenable to fast,<br />

flexible and modular expansion. The key and lamp functions can<br />

be changed later at any time without having to modify the wiring.<br />

■ Design<br />

PPs stand out because of their compact construction:<br />

Preassembled with 8 short-stroke keys that can be labeled<br />

individually with slide-in labels<br />

Smooth, easy to clean front;<br />

the front is resistant to various oils, greases and standard<br />

detergents<br />

Long-life, multi-colored surface LEDs in all short-stroke keys<br />

Additional digital inputs for flexible expansion<br />

Pre-perforated cut-outs for 22.5 mm standard auxiliary<br />

elements (buttons, lamps, Emergency Stop, key switch)<br />

Rear-side display with miniature keyboard for displaying<br />

operating status and changing standard settings in text format<br />

The PP7 fits seamlessly into the series<br />

Maintenance-friendly, no battery required<br />

All parameters are stored on a memory module, which can be<br />

easily replaced


■ Function<br />

LED color modes (e.g., red, green, yellow, red-flashing,<br />

green-flashing, yellow-flashing)<br />

Integrated flashing rate for LED<br />

Integrated diagnostic functions<br />

Integrated lamp and key test (also for additional digital inputs)<br />

Menu-assisted parameterization via rear display with<br />

miniature keyboard<br />

Short-stroke keys and digital inputs are also parameterizable<br />

as switches<br />

Parameterizable pulse stretching for short-stroke keys and<br />

digital inputs<br />

PROFIBUS DP standard slave<br />

■ Integration<br />

The Push Button Panels can be connected to<br />

SIMATIC S7-200/-300/-400, WinAC Software and Slot PLC via<br />

MPI and PROFIBUS DP<br />

SIMATIC S5 (AG95/master or IM 308C) only via PROFIBUS DP<br />

PROFIBUS DP standard master, any vendor<br />

(e.g. Allen Bradley, etc.)<br />

System interfaces<br />

Controller SIMATIC PP7 1)<br />

Target hardware (PROTOCOL) Connection via DP/MPI<br />

(connector/physics)<br />

SIMATIC S7/SIMATIC WinAC (MPI as master) 2)<br />

via MPI interface with<br />

S7-200/-300/-400/<br />

WinAC Software/Slot PLC<br />

(9-pin socket/RS 485) 3) 4)<br />

SIMATIC S5/S7 (PROFIBUS DP as standard slave)<br />

via PROFIBUS with max. 1 x<br />

S7-200 (CPU 215-DP)<br />

on MPI protocol<br />

S7-300/-400<br />

with integrated PROFIBUS interface<br />

S7-300 with CP 342-5<br />

S7-400 with CP 443-5<br />

via PROFIBUS DP with<br />

S5-95U/PROFIBUS DP master<br />

(6ES5 095-8ME02)<br />

S5-115U/-135U/-155U<br />

with IM 308C/IM 308B<br />

S5-115U/-135U/-155U<br />

with CP 5430/CP 5431<br />

Bus connector, bus cable<br />

and MPI network<br />

(see <strong>Catalog</strong> <strong>ST</strong> 70/IK PI)<br />

PROFIBUS 5)<br />

(see <strong>Catalog</strong> <strong>ST</strong> 70/IK PI)<br />

PROFIBUS 5)<br />

(see <strong>Catalog</strong> <strong>ST</strong> 70/IK PI)<br />

Non-<strong>Siemens</strong> controllers (PROFIBUS DP master)<br />

via PROFIBUS DP PROFIBUS<br />

1)<br />

PP7 suitable up to 1.5 Mbit/s<br />

2) Standard PG/<strong>PC</strong> MPI cable cannot be used<br />

3) S7-200 only via MPI (CPU 212 not possible)<br />

4) S7-200 CPU 215-DP also possible on PROFIBUS DP interface via<br />

MPI protocol<br />

5) Bus connector: 6GK1 500-0EA02<br />

5)<br />

(see <strong>Catalog</strong> <strong>ST</strong> 70/IK PI)<br />

Note:<br />

The standard PG/<strong>PC</strong> MPI cable (6ES7 901-0BF00-0AA0) cannot<br />

be used to connect a PP and a CPU.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Technical specifications<br />

Operator panels<br />

Key Panels<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC PP7<br />

6AV3 688-3AA03-0AX0<br />

General system features<br />

Short lift keys/additional inputs as Yes<br />

pushbuttons or switches<br />

max. pulse extension for short- 1000ms<br />

stroke keys and digital inputs<br />

Release input No<br />

Control elements<br />

Control elements Membrane keyboard<br />

Function keys, programmable 8 function keys, 8 with LEDs<br />

Membrane keyboard Yes<br />

Supply voltage<br />

Input voltage<br />

permissible range +18 V to +30 V DC<br />

Supply voltage 24 V DC<br />

Input current<br />

Rated current 0.2 A<br />

Power 5W<br />

Type of output<br />

LED colors Red, yellow, green<br />

Color modes for LED 3<br />

Number of LEDs 8<br />

Digital inputs<br />

Number of inputs 4<br />

Voltage (DC) 24 V<br />

Test commissioning functions<br />

Flashing frequency for LEDs 0.5 Hz<br />

Pushbutton and lamp test Yes<br />

Ambient conditions<br />

Operating temperature<br />

Operation (vertical installation) 0 °C to +55 °C<br />

Operation (max. tilt angle) 0 °C to +55 °C<br />

Storage/transport temperature<br />

Transport, storage -20 °C to +70 °C<br />

Relative humidity<br />

max. relative humidity 95 %<br />

Mounting position vertical<br />

maximum permissible angle of incli- +/- 35 °<br />

nation without external ventilation<br />

Degree and class of protection<br />

Front IP65<br />

Rear IP20<br />

Standards, approvals, certificates<br />

Certifications CE, FM Class I Div. 2, UL, CSA<br />

Mechanics/material<br />

Lifetime, typ.<br />

Short-stroke keys<br />

1500000<br />

(in switching cycles)<br />

LEDs (ON period) 100 %<br />

Dimensions and weight<br />

Dimensions<br />

Front of enclosure (W x H) 144 mm x 204 mm<br />

Mounting cutout/device depth<br />

(W x H)<br />

Weight<br />

Weight 0.8 kg<br />

130 mm x 190 mm / 53 mm<br />

device depth<br />

2/13<br />

2


2<br />

Operator panels<br />

Key Panels<br />

SIMATIC PP7<br />

■ Ordering data Order No.<br />

SIMATIC PP7<br />

Push Button Panel incl. mounting<br />

accessories:<br />

8 x short-stroke keys<br />

8 x surface lighting diodes<br />

4 x DI terminals (24 V)<br />

Max. 5 x 22.5 mm pre-perforated<br />

cutouts for additional<br />

components<br />

A 6AV3 688-3AA03-0AX0<br />

Documentation to be ordered separately<br />

Accessories see HMI accessories<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

Note:<br />

Commercially available printing film (0.13 to 0.16 mm strength)<br />

can be used as labeling strips for the keyboard. Word templates<br />

are enclosed with the manual on a diskette.<br />

2/14<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical<br />

specifications.<br />

SIMATIC PP7<br />

144<br />

128<br />

188<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-pbp<br />

204<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.<br />

108<br />

55<br />

204<br />

4<br />

30<br />

G_<strong>ST</strong><strong>80</strong>_XX_00061


■ Overview<br />

SIMATIC Push Button Panels are the innovative alternative to<br />

conventional operator panels for easy and direct control of<br />

machines:<br />

Pre-fabricated and ready for operation;<br />

simply connect to the control and all buttons and lamps are<br />

ready for immediate use<br />

Connection to any type of control via a bus cable<br />

(PROFIBUS DP as "standard slave" or MPI)<br />

PP17-I:<br />

Fitted with short-stroke keys, additional digital inputs and<br />

outputs and slots for 22.5 mm standard elements<br />

PP17-II:<br />

Fitted with short-stroke keys, additional digital inputs and<br />

outputs and much more<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Key Panels<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC PP17<br />

■ Benefits<br />

Up to 90 % time savings: Pushbuttons, switches and lamps do<br />

not have to be fitted and wired individually<br />

Use of standard cables, for example, makes configuration and<br />

startup easier<br />

No configuration tool required<br />

Service-friendly thanks to rear display to indicate operating<br />

states and messages in plain text, without programming<br />

device<br />

Quick and easy machine operation thanks to multi-colored<br />

indicator lights<br />

User-friendly labeling option for pushbuttons and lamps using<br />

slide-in labels<br />

As the 22.5 mm standard elements can be connected directly<br />

on the panel, no additional wiring and I/O modules are<br />

required<br />

■ Application<br />

The rugged PP17 Push Button Panels are designed for easy and<br />

straight-forward operation of the machine.<br />

They can be used wherever keys and lamps are essential<br />

components in operator control and monitoring. In the food<br />

processing industry, for example, on machines and systems on<br />

which smooth fronts are required for easier cleaning. Even in<br />

special mechanical equipment manufacture, the push button<br />

panels can be used to easily set up standard operator panels<br />

that are then amenable to fast, flexible and modular expansion.<br />

The key and lamp functions can be changed later at any time<br />

without having to modify the wiring.<br />

■ Design<br />

PPs stand out because of their compact construction:<br />

Preassembled with short-stroke keys that can be labeled<br />

individually - also in color - with slide-in labels<br />

Smooth, easy to clean front;<br />

the front is resistant to various oils, greases and standard<br />

detergents<br />

Long-life, multi-colored surface LEDs in all short-stroke keys<br />

Additional digital inputs and outputs for flexible expansion<br />

Pre-perforated cut-outs for 22.5 mm standard auxiliary<br />

elements (buttons, lamps, etc.) for PP17-I<br />

Rear-side display with miniature keyboard for displaying<br />

operating states and changing standard settings in text format<br />

Central enabling input<br />

The PP17 can be laterally mounted<br />

Maintenance-friendly, no battery required<br />

All parameters are stored on a memory module, which can be<br />

easily replaced<br />

2/15<br />

2


2<br />

Operator panels<br />

Key Panels<br />

SIMATIC PP17<br />

■ Function<br />

LED color modes (e.g. red, green, yellow, red-flashing,<br />

green-flashing, yellow-flashing)<br />

Integrated flashing frequency for digital outputs and LED<br />

Integrated diagnostic functions<br />

Integrated lamp and key test (also for additional digital inputs<br />

24 V inputs and outputs)<br />

Menu-assisted parameterization via rear display with<br />

miniature keyboard<br />

Short-stroke keys and digital inputs are also parameterizable<br />

as switches<br />

Parameterizable pulse stretching for short-stroke keys and<br />

digital inputs (max. 1000 ms)<br />

PROFIBUS DP standard slave<br />

■ Integration<br />

The Push Button Panels can be connected to:<br />

SIMATIC S7-200/-300/-400, WinAC Software and Slot PLC via<br />

MPI and PROFIBUS DP<br />

SIMATIC S5 (AG95/master or IM 308C) only via PROFIBUS DP<br />

PROFIBUS DP standard master, any vendor (e.g. Allen<br />

Bradley, etc.)<br />

System interfaces<br />

Controller SIMATIC PP17 1)<br />

Target hardware (PROTOCOL) Connection via DP/MPI<br />

(connector/physics)<br />

SIMATIC S7/SIMATIC WinAC (MPI as master) 2)<br />

via MPI interface with<br />

S7-200/-300/-400/<br />

WinAC Software/Slot PLC<br />

(9-pin socket/RS 485), 3)4)<br />

SIMATIC S5/S7 (PROFIBUS DP as standard slave)<br />

via PROFIBUS with max. 1 x<br />

S7-200 (CPU 215-DP)<br />

on MPI protocol<br />

S7-300/-400<br />

with integrated PROFIBUS interface<br />

S7-300 with CP 342-5<br />

S7-400 with CP 443-5<br />

via PROFIBUS DP with<br />

S5-95U/PROFIBUS DP master<br />

(6ES5 095-8ME02)<br />

S5-115U/-135U/-155U<br />

with IM 308C/IM 308B<br />

S5-115U/-135U/-155U<br />

with CP 5430/CP 5431<br />

Non-<strong>Siemens</strong> controllers (PROFIBUS DP master)<br />

via PROFIBUS DP PROFIBUS<br />

1) PP17 suitable up to 12 Mbit/s<br />

2) Standard PG/<strong>PC</strong> MPI cable cannot be used<br />

3) S7-200 only via MPI (CPU 212 not possible)<br />

4) S7-200 CPU 215-DP also possible on PROFIBUS DP interface via<br />

MPI protocol<br />

5) Bus connector: 6GK1 500-0EA02<br />

5)<br />

(see <strong>Catalog</strong> <strong>ST</strong> 70/IK PI)<br />

Note:<br />

The standard PG/<strong>PC</strong> MPI cable (6ES7 901-0BF00-0AA0) cannot<br />

be used to connect a PP and a CPU.<br />

2/16<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Bus connector, connecting<br />

cable and MPI network<br />

(see <strong>Catalog</strong> <strong>ST</strong> 70/IK PI)<br />

PROFIBUS 5)<br />

(see <strong>Catalog</strong> <strong>ST</strong> 70/IK PI)<br />

PROFIBUS 5)<br />

(see <strong>Catalog</strong> <strong>ST</strong> 70/IK PI)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Technical specifications<br />

6AV3 688-3CD13-<br />

0AX0<br />

6AV3 688-3ED13-<br />

0AX0<br />

Product type designation<br />

General system features<br />

PP17-I PP17-II<br />

Short lift keys/additional<br />

inputs as pushbuttons or<br />

switches<br />

Yes Yes<br />

max. pulse extension for<br />

short-stroke keys and digital<br />

inputs<br />

1000ms 1000ms<br />

Release input Yes Yes<br />

Control elements<br />

Control elements Membrane<br />

keyboard<br />

Function keys,<br />

programmable<br />

16 function keys,<br />

16 with LEDs<br />

Membrane<br />

keyboard<br />

32 function keys,<br />

32 with LEDs<br />

Supply voltage<br />

Input voltage<br />

permissible range +18 V to +30 V DC +18 V to +30 V DC<br />

Supply voltage<br />

Input current<br />

24 V DC 24 V DC<br />

Rated current 0.4 A 0.4 A<br />

Power<br />

Type of output<br />

10 W 10 W<br />

LED colors Red, yellow, green Red, yellow, green<br />

Color modes for LED 3 3<br />

Number of LEDs<br />

Digital inputs<br />

16 32<br />

Number of inputs 16 16<br />

Voltage (DC)<br />

Digital outputs<br />

24 V 24 V<br />

Total power 12 W 12 W<br />

Number of outputs 16 16<br />

in groups of 4 4<br />

Total current (per group),<br />

max.<br />

500 mA 500 mA<br />

Short-circuit protection<br />

Test commissioning<br />

functions<br />

Yes Yes<br />

Flashing frequency for LEDs 0.5 Hz 0.5 Hz<br />

Flashing frequency for digital<br />

outputs<br />

0.5 Hz or 2 Hz 0.5 Hz or 2 Hz<br />

Pushbutton and lamp test<br />

Ambient conditions<br />

Operating temperature<br />

Yes Yes<br />

Operation<br />

(vertical installation)<br />

0 °C to +55 °C 0 °C to +55 °C<br />

Operation (max. tilt angle)<br />

Storage/transport<br />

temperature<br />

0 °C to +55 °C 0 °C to +55 °C<br />

Transport, storage<br />

Relative humidity<br />

-20 °C to +70 °C -20 °C to +70 °C<br />

max. relative humidity 95 % 95 %<br />

Mounting position vertical vertical<br />

maximum permissible angle<br />

of inclination without external<br />

ventilation<br />

+/- 35 ° +/- 35 °


© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Key Panels<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC PP17<br />

■ Technical specifications (continued)<br />

■ Ordering data Order No.<br />

6AV3 688-3CD13- 6AV3 688-3ED13- PP17-I A 6AV3 688-3CD13-0AX0<br />

0AX0<br />

0AX0<br />

Push Button Panel incl. mounting<br />

Degree and class of<br />

accessories:<br />

protection<br />

16 x short-stroke keys<br />

Front IP65 IP65<br />

16 x surface lighting diodes<br />

Rear IP20 IP20<br />

16 x DI terminals (24 V)<br />

Standards, approvals,<br />

certificates<br />

16 x DO terminals (24 V)<br />

Certifications CE, FM Class I CE, FM Class I 1 x enabling input<br />

Div. 2, UL, CSA Div. 2, UL, CSA<br />

Max. 12 x 22.5 mm pre-perfo-<br />

Mechanics/material<br />

rated cutouts for additional<br />

Lifetime, typ.<br />

components<br />

Short-stroke keys<br />

1500000 1500000<br />

PP17-II A 6AV3 688-3ED13-0AX0<br />

(in switching cycles)<br />

LEDs (ON period) 100 % 100 %<br />

Push Button Panel incl. mounting<br />

accessories:<br />

Dimensions and weight<br />

32 x short-stroke keys<br />

Dimensions<br />

Front of enclosure (W x H)<br />

Mounting cutout/device<br />

240 mm x 204 mm<br />

226 mm x 190 mm<br />

240 mm x 204 mm<br />

226 mm x 190 mm<br />

32 x surface lighting diodes<br />

16 x DI terminals (24 V)<br />

depth (W x H)<br />

Weight<br />

/ 53 mm device<br />

depth<br />

/ 53 mm device<br />

depth<br />

16 x DO terminals (24 V)<br />

1 x enabling input<br />

Weight 1.2 kg 1.5 kg<br />

Documentation To be ordered separately<br />

Accessories for supplementary<br />

ordering<br />

see HMI accessories<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

Note:<br />

Commercially available printing film (0.13 to 0.16 mm strength)<br />

can be used as labeling strips for the keyboard. Word templates<br />

are enclosed with the manual on a diskette.<br />

2/17<br />

2


2<br />

Operator panels<br />

Key Panels<br />

SIMATIC PP17<br />

■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical specifications.<br />

SIMATIC PP17-I<br />

SIMATIC PP17-II<br />

2/18<br />

240<br />

224<br />

240<br />

224<br />

188<br />

188<br />

204<br />

204<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

95<br />

99<br />

53<br />

53<br />

204<br />

4<br />

32<br />

204<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

4<br />

32<br />

G_<strong>ST</strong><strong>80</strong>_XX_00059<br />

G_<strong>ST</strong><strong>80</strong>_XX_00060<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-pbp<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.


■ Overview<br />

1) ISA-S71.04 severity level GX: Long-term load: SO2 < 4.8 ppm;<br />

H2S < 9.9 ppm; Cl < 0.2 ppm; HCl < 0.66 ppm; HF < 0.12 ppm;<br />

NH < 49 ppm; O3 < 0.1 ppm; NOX < 5.2 ppm<br />

Limit value (max. 30 min/d): SO2 < 17.8 ppm; H2S < 49.7 ppm;<br />

Cl < 1.0 ppm; HCl < 3.3 ppm; HF < 2.4 ppm; NH < 247 ppm;<br />

O3


2<br />

Operator panels<br />

Basic Panels<br />

Basic Panels – Standard<br />

■ Overview<br />

2/20<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Application<br />

The SIMATIC HMI Basic Panels can be used wherever compact<br />

machines and plants are controlled and monitored locally - in<br />

production, process and building automation alike. They are<br />

used in the most diverse sectors and applications.<br />

■ Design<br />

The SIMATIC HMI Basic Panels are installation-compatible with<br />

the existing touch devices of the product family of Panels and<br />

Multi Panels.<br />

KP300 Basic mono PN<br />

3.6" F<strong>ST</strong>N black/white<br />

1 Ethernet interface (TCP/IP, PROFINET)<br />

Touch device with 10 function keys and 10 system keys<br />

KTP400 Basic mono PN<br />

3.8" <strong>ST</strong>N mono<br />

1 Ethernet interface (TCP/IP, PROFINET)<br />

Ideal entry-level series from 3" to 15" for operator control and Touch screen and 4 tactile function keys<br />

monitoring compact machines and systems<br />

Clear process representation thanks to use of pixel-graphic KTP600 Basic mono PN<br />

displays<br />

5.7" <strong>ST</strong>N mono<br />

Intuitive operation using Touch and tactile function keys<br />

1 Ethernet interface (TCP/IP, PROFINET)<br />

Equipped with all the necessary basic functions such as alarm Touch screen and 6 tactile function keys<br />

logging, recipe management, plots, vector graphics, and<br />

language switching<br />

KTP600 Basic color PN or DP<br />

Simple connection to the controller via integrated Ethernet 5.7" TFT with 256 colors<br />

interface or separate version with RS485/422<br />

1 Ethernet interface (TCP/IP, PROFINET) or<br />

1 RS 485/422 interface (MPI, PROFIBUS DP; separate<br />

■ Benefits<br />

version)<br />

Touch screen and 6 tactile function keys<br />

Integral component of Totally Integrated Automation (TIA):<br />

Increased productivity, minimum engineering overhead, KTP1000 Basic color PN or DP<br />

reduction in life-cycle costs<br />

10.4" TFT with 256 colors<br />

- Can be used even where installation space is restricted<br />

thanks to vertical configuring (4" and 6" devices)<br />

Ethernet interface (TCP/IP, PROFINET) or<br />

- Short configuring and commissioning times<br />

1 RS 485/422 interface (MPI, PROFIBUS DP; separate<br />

- Service-friendly thanks to maintenance-free design and long version)<br />

service life of the backlighting display<br />

Touch screen and 8 tactile function keys<br />

Simple and user-friendly representation of process values<br />

TP1500 Basic color PN<br />

thanks to, for example, input/output fields, vector graphics,<br />

trend curves, bar charts, text and bitmaps<br />

15.0" TFT with 256 colors<br />

Graphic library available with off-the-shelf picture objects 1 Ethernet interface (TCP/IP, PROFINET)<br />

touch screen<br />

Can be used worldwide:<br />

- 32 languages can be configured (incl. Asian and Cyrillic<br />

character sets)<br />

- You can switch between up to 5 languages online<br />

- Language-dependent texts and graphics


■ Function<br />

Input/output fields<br />

for displaying and modifying process parameters<br />

Buttons<br />

are used for direct triggering of functions and actions. Up to<br />

16 functions can be configured simultaneously on buttons.<br />

Graphics<br />

can be used as icons instead of text to "label" function keys or<br />

buttons. They can also be used as full-screen background<br />

images.<br />

The configuration tool contains a library with extensive<br />

graphics and diverse objects. All editors with an OLE interface<br />

(such as PaintShop, Designer or CorelDraw) can be used as<br />

graphic editors<br />

Vector graphics<br />

Simple geometric basic forms (line, circle and rectangle) can<br />

be created direct in the configuring tool<br />

Fixed texts<br />

for labeling function keys, process images and process<br />

values in different font sizes<br />

Curve functions and bars<br />

are used for graphical display of dynamic values<br />

Language switching:<br />

- 5 online languages, 32 configuration languages incl. Asian<br />

and Cyrillic character sets<br />

- Language-dependent texts and graphics<br />

User administration (security) in accordance with the<br />

requirements of the different sectors<br />

- Authentication with user ID and password<br />

- User-group-specific rights<br />

Signaling system<br />

- Discrete alarms<br />

- Analog alarms<br />

- Freely definable message classes (e.g. status/fault<br />

messages) for defining acknowledgment response and<br />

displaying alarm events<br />

- Message history<br />

Recipe management<br />

Help texts<br />

for process screens, messages and variables<br />

Arithmetic functions<br />

Limit value monitoring<br />

for reliable process control of inputs and outputs<br />

Indicator light<br />

for indicating machine and plant statuses<br />

Scheduler for global function execution in case of global<br />

events<br />

Template concept for creation of screen templates (screen<br />

elements configured in the template appear in every screen)<br />

Simple maintenance and configuration thanks to:<br />

- Backup/restore of configuration, operating system and<br />

firmware on/from a <strong>PC</strong> using ProSave<br />

- Configuration download via MPI/PROFIBUS DP or<br />

PROFINET<br />

- Automatic transfer identification<br />

- Individual contrast or brightness setting (except 6" color)<br />

and calibration<br />

- Clean screen<br />

- No battery required<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Basic Panels<br />

Basic Panels – Standard<br />

Configuration<br />

The configuration is implemented using the engineering<br />

software SIMATIC WinCC Basic, Comfort, Professional or<br />

SIMATIC <strong>ST</strong>EP 7 Basic (with integrated WinCC Basic).<br />

The 4" to 15" devices can also be configured using the<br />

SIMATIC WinCC flexible Compact, Standard or Advanced<br />

engineering software.<br />

■ Integration<br />

The Basic Panels can be connected to:<br />

SIMATIC S7 controllers<br />

Non-<strong>Siemens</strong> controllers (applies for DP devices)<br />

- Allen Bradley DF1<br />

- Modicon Modbus RTU<br />

- Mitsubishi FX<br />

- Omron Hostlink/Multilink<br />

Non-<strong>Siemens</strong> controllers (non-<strong>Siemens</strong> drivers for<br />

PN devices)<br />

- Allen Bradley Ethernet/IP<br />

- Modicon Modbus TCP/IP<br />

- Mitsubishi MC TCP/IP<br />

Note:<br />

For further information, see "System interfaces".<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/21<br />

2


2<br />

Operator panels<br />

Basic Panels<br />

Basic Panels – Standard<br />

■ Technical specifications<br />

6AV6 647-0AH11- 6AV6 647-0AA11- 6AV6 647-0AB11- 6AV6 647-0AC11- 6AV6 647-0AD11-<br />

3AX0<br />

3AX0<br />

3AX0<br />

3AX0<br />

3AX0<br />

Product type<br />

SIMATIC HMI KP300 SIMATIC HMI KTP400 SIMATIC HMI KTP600 SIMATIC HMI KTP600 SIMATIC HMI KTP600<br />

designation<br />

Display<br />

Basic mono PN Basic mono PN Basic mono PN Basic color DP Basic color PN<br />

Size 3.8"<br />

5.7"<br />

5.7"<br />

5.7"<br />

(76.8 mm x 57.6 mm) (115.2 mm x 86.4 mm) (115.2 mm x 86.4 mm) (115.2 mm x 86.4 mm)<br />

Display type<br />

Resolution (pixels)<br />

<strong>ST</strong>N, gray scales <strong>ST</strong>N, gray scales TFT, 256 colors TFT, 256 colors<br />

Resolution<br />

(WxH in pixel)<br />

Backlighting<br />

320 x 240 320 x 240 320 x 240 320 x 240<br />

MTBF backlighting<br />

(at 25 °C)<br />

Control elements<br />

Approx. 30000 hours about 50,000 hours about 50,000 hours about 50,000 hours<br />

Control elements Membrane keyboard Membrane keyboard Membrane keyboard Membrane keyboard Membrane keyboard<br />

Function keys,<br />

programmable<br />

4 function keys 6 function keys 6 function keys 6 function keys<br />

Connection for<br />

mouse/keyboard/barcod<br />

e reader<br />

- / - / - - / - / - - / - / - - / - / - - / - / -<br />

Keyboard<br />

System keys 10<br />

Numeric/alphabetical<br />

input<br />

2/22<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Yes (on-screen<br />

keyboard) / Yes<br />

(on-screen keyboard)<br />

Yes (on-screen<br />

keyboard) / Yes<br />

(on-screen keyboard)<br />

Yes (on-screen<br />

keyboard) / Yes<br />

(on-screen keyboard)<br />

Yes (on-screen<br />

keyboard) / Yes<br />

(on-screen keyboard)<br />

Touch operation<br />

Touch screen<br />

Supply voltage<br />

Input voltage<br />

No analog, resistive analog, resistive analog, resistive analog, resistive<br />

permissible range +19.2 V to +28.8 V DC +19.2 V to +28.8 V DC +19.2 V to +28.8 V DC +19.2 V to +28.8 V DC +19.2 V to +28.8 V DC<br />

Supply voltage<br />

Input current<br />

24 V DC 24 V DC 24 V DC 24 V DC 24 V DC<br />

Rated current<br />

Memory<br />

0.1 A 0.07 A 0.24 A 0.35 A 0.35 A<br />

Type Flash / RAM Flash / RAM Flash / RAM Flash / RAM Flash / RAM<br />

Usable memory for user<br />

data<br />

512 KB usable<br />

memory for user data<br />

512 KB usable<br />

memory for user data<br />

512 KB usable<br />

memory for user data<br />

512 KB usable<br />

memory for user data<br />

Type of output<br />

Acoustics Sound signal Sound signal Sound signal Sound signal<br />

Time of day<br />

Clock<br />

Type Software clock, no<br />

battery backup<br />

Software clock, no<br />

battery backup<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Software clock, no<br />

battery backup<br />

Software clock, no<br />

battery backup<br />

Software clock, no<br />

battery backup<br />

Interfaces<br />

Interfaces 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x RS422,1 x RS485<br />

(max. 12 Mbit/s)<br />

1 x Ethernet (RJ45)<br />

USB port No No No No No<br />

<strong>PC</strong> card slot No No No No No<br />

CF card slot No No No No No<br />

Multi Media Card slot<br />

Industrial Ethernet<br />

No No No No No<br />

Industrial Ethernet<br />

interface<br />

1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) No 1 x Ethernet (RJ45)


■ Technical specifications (continued)<br />

Product type<br />

designation<br />

Operator panels<br />

Basic Panels<br />

Basic Panels – Standard<br />

Protocols<br />

Protocols (terminal link)<br />

Sm@rtAccess<br />

Ambient conditions<br />

Operating temperature<br />

No No No No No<br />

Operation (vertical<br />

installation)<br />

0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °C<br />

Operation (max. tilt<br />

angle)<br />

Storage/transport<br />

temperature<br />

0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C<br />

Transport, storage<br />

Relative humidity<br />

-20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C<br />

max. relative humidity 90 % 90 % 90 % 90 % 90 %<br />

Mounting position vertical vertical vertical vertical vertical<br />

maximum permissible<br />

angle of inclination<br />

without external ventilation<br />

+/- 35 ° +/- 35 ° +/- 35 ° +/- 35 ° +/- 35 °<br />

Degree and class of<br />

protection<br />

Front IP65, NEMA 4,<br />

NEMA 4x, NEMA 12<br />

(when installed)<br />

6AV6 647-0AH11- 6AV6 647-0AA11- 6AV6 647-0AB11- 6AV6 647-0AC11-<br />

3AX0<br />

3AX0<br />

3AX0<br />

3AX0<br />

SIMATIC HMI KP300 SIMATIC HMI KTP400 SIMATIC HMI KTP600 SIMATIC HMI KTP600<br />

Basic mono PN Basic mono PN Basic mono PN Basic color DP<br />

IP65, NEMA 4,<br />

NEMA 4x, NEMA 12<br />

(when installed)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

IP65, NEMA 4,<br />

NEMA 4x, NEMA 12<br />

(when installed)<br />

IP65, NEMA 4,<br />

NEMA 4x, NEMA 12<br />

(when installed)<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6AV6 647-0AD11-<br />

3AX0<br />

SIMATIC HMI KTP600<br />

Basic color PN<br />

IP65, NEMA 4,<br />

NEMA 4x, NEMA 12<br />

(when installed)<br />

Rear<br />

Configuration<br />

Configuration software<br />

IP20 IP20 IP20 IP20 IP20<br />

Configuration tool<br />

Functionality under<br />

WinCC flexible/<br />

WinCC (TIA portal)<br />

see "Configuration overview" from page 2/3<br />

Applications/options see chapter 4: HMI software/SIMATIC WinCC flexible options and SIMATIC WinCC (TIA portal) options<br />

Number of Visual Basic<br />

Scripts<br />

Not possible Not possible Not possible Not possible Not possible<br />

Task planner Yes Yes Yes Yes Yes<br />

Help system Yes Yes Yes Yes Yes<br />

Status/control<br />

With alarm logging<br />

system (incl. buffer and<br />

acknowledgment)<br />

Not possible Not possible Not possible Not possible Not possible<br />

Number of messages 200 200 200 200 200<br />

Bit messages Yes Yes Yes Yes Yes<br />

Analog messages Yes Yes Yes Yes Yes<br />

Message buffer Ring buffer<br />

Ring buffer<br />

Ring buffer<br />

Ring buffer<br />

Ring buffer<br />

(n x 256 entries), (n x 256 entries), (n x 256 entries), (n x 256 entries), (n x 256 entries),<br />

retentive, mainte- retentive, mainte- retentive, mainte- retentive, mainte- retentive, maintenance-freenance-freenance-freenance-freenance-free<br />

2/23<br />

2


2<br />

Operator panels<br />

Basic Panels<br />

Basic Panels – Standard<br />

■ Technical specifications (continued)<br />

6AV6 647-0AH11- 6AV6 647-0AA11- 6AV6 647-0AB11- 6AV6 647-0AC11- 6AV6 647-0AD11-<br />

3AX0<br />

3AX0<br />

3AX0<br />

3AX0<br />

3AX0<br />

Product type<br />

SIMATIC HMI KP300 SIMATIC HMI KTP400 SIMATIC HMI KTP600 SIMATIC HMI KTP600 SIMATIC HMI KTP600<br />

designation<br />

Recipes<br />

Basic mono PN Basic mono PN Basic mono PN Basic color DP Basic color PN<br />

Recipes 5 5 5 5 5<br />

Data records per<br />

recipe<br />

20 20 20 20 20<br />

Entries per data record 20 20 20 20 20<br />

Recipe memory 40 KB integrated 40 KB integrated 40 KB integrated 40 KB integrated 40 KB integrated<br />

Number of process<br />

images<br />

Flash<br />

Flash<br />

Flash<br />

Flash<br />

Flash<br />

Process images 50 50 50 50 50<br />

Variables 250 250 500 500 500<br />

Limit values Yes Yes Yes Yes Yes<br />

Multiplexing<br />

Image elements<br />

Yes Yes Yes Yes Yes<br />

Text objects 500 text elements 500 text elements 500 text elements 500 text elements 500 text elements<br />

Graphic object Bit maps, icons, icon Bit maps, icons, icon Bit maps, icons, icon Bit maps, icons, icon Bit maps, icons, icon<br />

(full-screen), vector (full-screen), vector (full-screen), vector (full-screen), vector (full-screen), vector<br />

graphics<br />

graphics<br />

graphics<br />

graphics<br />

graphics<br />

dynamic objects<br />

Lists<br />

Diagrams, bar graphs Diagrams, bar graphs Diagrams, bar graphs Diagrams, bar graphs Diagrams, bar graphs<br />

Text lists 150 150 150 150 150<br />

Graphic list 100 100 100 100 100<br />

Libraries<br />

Security<br />

Yes Yes Yes Yes Yes<br />

Number of user groups 50 50 50 50 50<br />

Passwords exportable No No No No No<br />

Number of user rights<br />

Data carrier support<br />

32 32 32 32 32<br />

<strong>PC</strong> card No No No No No<br />

CF card No No No No No<br />

Multimedia Card<br />

Recording<br />

No No No No No<br />

Recording/Printing<br />

Fonts<br />

- - - - -<br />

Keyboard fonts<br />

Languages<br />

US American (English) US American (English) US American (English) US American (English) US American (English)<br />

Configuration<br />

D, GB, F, I, E, CHN D, GB, F, I, E, CHN D, GB, F, I, E, CHN D, GB, F, I, E, CHN D, GB, F, I, E, CHN<br />

languages<br />

"traditional", CHN "traditional", CHN "traditional", CHN "traditional", CHN "traditional", CHN<br />

"simplified", DK, FIN, "simplified", DK, FIN, "simplified", DK, FIN, "simplified", DK, FIN, "simplified", DK, FIN,<br />

GR, J, KP / ROK, NL, GR, J, KP / ROK, NL, GR, J, KP / ROK, NL, GR, J, KP / ROK, NL, GR, J, KP / ROK, NL,<br />

N, PL, P, RUS, S, CZ / N, PL, P, RUS, S, CZ / N, PL, P, RUS, S, CZ / N, PL, P, RUS, S, CZ / N, PL, P, RUS, S, CZ /<br />

SK, TR, H<br />

SK, TR, H<br />

SK, TR, H<br />

SK, TR, H<br />

SK, TR, H<br />

Character sets Tahoma, WinCC Tahoma, WinCC Tahoma, WinCC Tahoma, WinCC Tahoma, WinCC<br />

flexible Standard, flexible Standard, flexible Standard, flexible Standard, flexible Standard,<br />

symbol languages symbol languages symbol languages symbol languages symbol languages<br />

2/24<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Technical specifications (continued)<br />

6AV6 647-0AH11-<br />

3AX0<br />

Product type<br />

SIMATIC HMI KP300<br />

designation<br />

Basic mono PN<br />

Transfer<br />

(upload/download)<br />

Transfer of configuration<br />

Ethernet, automatic<br />

transfer recognition<br />

Ethernet, automatic<br />

transfer recognition<br />

Ethernet, automatic<br />

transfer recognition<br />

Operator panels<br />

Basic Panels<br />

MPI/PROFIBUS DP,<br />

serial, automatic<br />

transfer recognition<br />

Basic Panels – Standard<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Ethernet, automatic<br />

transfer recognition<br />

Process coupling<br />

Connection to<br />

controller<br />

Expandability/openness<br />

see "System interfaces" from page 2/178<br />

Open Platform<br />

Program<br />

I/O<br />

No No No No No<br />

I/O devices<br />

Dimensions and<br />

weight<br />

Dimensions<br />

None None None None None<br />

Front of enclosure<br />

(W x H)<br />

140 mm x 116 mm 214 mm x 158 mm 214 mm x 158 mm 214 mm x 158 mm<br />

Mounting<br />

cutout/device depth<br />

(W x H)<br />

6AV6 647-0AA11- 6AV6 647-0AB11- 6AV6 647-0AC11-<br />

3AX0<br />

3AX0<br />

3AX0<br />

SIMATIC HMI KTP400 SIMATIC HMI KTP600 SIMATIC HMI KTP600<br />

Basic mono PN Basic mono PN Basic color DP<br />

123 mm x 99 mm/<br />

40 mm device depth<br />

197 mm x 141 mm/<br />

44 mm device depth<br />

197 mm x 141 mm/<br />

44 mm device depth<br />

Weight<br />

Weight 0.25 kg 1.07 kg 1.07 kg 1.07 kg<br />

Product type designation SIMATIC HMI KTP1000 Basic<br />

color DP<br />

6AV6 647-0AD11-<br />

3AX0<br />

SIMATIC HMI KTP600<br />

Basic color PN<br />

197 mm x 141 mm/<br />

44 mm device depth<br />

6AV6 647-0AE11-3AX0 6AV6 647-0AF11-3AX0 6AV6 647-0AG11-3AX0<br />

SIMATIC HMI KTP1000 Basic<br />

color PN<br />

SIMATIC HMI TP1500 Basic<br />

color PN<br />

Display<br />

Size 10.4" (211.2 mm x 158.4 mm) 10.4" (211.2 mm x 158.4 mm) 15" (304.1 mm x 228.1 mm)<br />

Display type<br />

Resolution (pixels)<br />

TFT, 256 colors TFT, 256 colors TFT, 256 colors<br />

Resolution (WxH in pixel)<br />

Backlighting<br />

640 x 4<strong>80</strong> 640 x 4<strong>80</strong> 1024 x 768<br />

MTBF backlighting (at 25 °C)<br />

Control elements<br />

about 50,000 hours about 50,000 hours about 50,000 hours<br />

Control elements Membrane keyboard Membrane keyboard Touch screen<br />

Function keys, programmable 8 function keys 8 function keys None<br />

Connection for<br />

mouse/keyboard/barcode reader<br />

- / - / - - / - / - - / - / -<br />

Keyboard<br />

Numeric/alphabetical input Yes (on-screen keyboard) / Yes<br />

(on-screen keyboard)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Yes (on-screen keyboard) / Yes<br />

(on-screen keyboard)<br />

Yes (on-screen keyboard) / Yes<br />

(on-screen keyboard)<br />

Touch operation<br />

Touch screen<br />

Supply voltage<br />

Input voltage<br />

analog, resistive analog, resistive analog, resistive<br />

permissible range +19.2 V to +28.8 V DC +19.2 V to +28.8 V DC +19.2 V to +28.8 V DC<br />

Supply voltage<br />

Input current<br />

24 V DC 24 V DC 24 V DC<br />

Rated current 0.6 A 0.6 A 0.8 A<br />

2/25<br />

2


2<br />

Operator panels<br />

Basic Panels<br />

Basic Panels – Standard<br />

■ Technical specifications (continued)<br />

Product type designation SIMATIC HMI KTP1000 Basic<br />

color DP<br />

Memory<br />

Type Flash / RAM Flash / RAM Flash / RAM<br />

Usable memory for user data 1024 KB usable memory for user<br />

data<br />

2/26<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

1024 KB usable memory for user<br />

data<br />

1024 KB usable memory for user<br />

data<br />

Type of output<br />

Acoustics<br />

Time of day<br />

Clock<br />

Sound signal Sound signal Sound signal<br />

Type<br />

Interfaces<br />

Software clock, no battery backup Software clock, no battery backup Software clock, no battery backup<br />

Interfaces 1 x RS422,1 x RS485<br />

(max. 12 Mbit/s)<br />

1 x Ethernet (RJ45) 1 x Ethernet (RJ45)<br />

USB port No No No<br />

<strong>PC</strong> card slot No No No<br />

CF card slot No No No<br />

Multi Media Card slot<br />

Industrial Ethernet<br />

No No No<br />

Industrial Ethernet interface<br />

Protocols<br />

Protocols (terminal link)<br />

No 1 x Ethernet (RJ45) 1 x Ethernet (RJ45)<br />

Sm@rtAccess<br />

Ambient conditions<br />

Operating temperature<br />

No No No<br />

Operation (vertical installation) 0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °C<br />

Operation (max. tilt angle)<br />

Storage/transport temperature<br />

0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C<br />

Transport, storage<br />

Relative humidity<br />

-20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C<br />

max. relative humidity 90 % 90 % 90 %<br />

Mounting position vertical vertical vertical<br />

maximum permissible angle of inclination<br />

without external ventilation<br />

+/- 35 ° +/- 35 ° +/- 35 °<br />

Degree and class of protection<br />

Front IP65, NEMA 4, NEMA 4x, NEMA 12<br />

(when installed)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV6 647-0AE11-3AX0 6AV6 647-0AF11-3AX0 6AV6 647-0AG11-3AX0<br />

SIMATIC HMI KTP1000 Basic<br />

color PN<br />

IP65, NEMA 4, NEMA 4x, NEMA 12<br />

(when installed)<br />

Rear<br />

Configuration<br />

Configuration software<br />

IP20 IP20 IP20<br />

Configuration tool see "Configuration overview" from page 2/3<br />

SIMATIC HMI TP1500 Basic<br />

color PN<br />

IP65, NEMA 4, NEMA 4x, NEMA 12<br />

(when installed)


■ Technical specifications (continued)<br />

Product type designation SIMATIC HMI KTP1000 Basic<br />

color DP<br />

Operator panels<br />

Basic Panels<br />

Basic Panels – Standard<br />

Functionality under WinCC<br />

flexible/WinCC (TIA Portal)<br />

Applications/options see chapter 4: HMI software/SIMATIC WinCC flexible options and SIMATIC WinCC (TIA portal) option<br />

Number of Visual Basic Scripts Not possible Not possible Not possible<br />

Task planner Yes Yes Yes<br />

Help system Yes Yes Yes<br />

Status/control<br />

With alarm logging system<br />

(incl. buffer and acknowledgment)<br />

Not possible Not possible Not possible<br />

Number of messages 200 200 200<br />

Bit messages Yes Yes Yes<br />

Analog messages Yes Yes Yes<br />

Message buffer Ring buffer (n x 256 entries),<br />

retentive, maintenance-free<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV6 647-0AE11-3AX0 6AV6 647-0AF11-3AX0 6AV6 647-0AG11-3AX0<br />

SIMATIC HMI KTP1000 Basic<br />

color PN<br />

Ring buffer (n x 256 entries),<br />

retentive, maintenance-free<br />

SIMATIC HMI TP1500 Basic<br />

color PN<br />

Ring buffer (n x 256 entries),<br />

retentive, maintenance-free<br />

Recipes<br />

Recipes 5 5 5<br />

Data records per recipe 20 20 20<br />

Entries per data record 20 20 20<br />

Recipe memory<br />

Number of process images<br />

40 KB integrated Flash 40 KB integrated Flash 40 KB integrated Flash<br />

Process images 50 50 50<br />

Variables 500 500 500<br />

Limit values Yes Yes Yes<br />

Multiplexing<br />

Image elements<br />

Yes Yes Yes<br />

Text objects 500 text elements 500 text elements 500 text elements<br />

Graphic object Bit maps, icons, icon (full-screen), Bit maps, icons, icon (full-screen), Bit maps, icons, icon (full-screen),<br />

vector graphics<br />

vector graphics<br />

vector graphics<br />

dynamic objects<br />

Lists<br />

Diagrams, bar graphs Diagrams, bar graphs Diagrams, bar graphs<br />

Text lists 150 150 150<br />

Graphic list 100 100 100<br />

Libraries<br />

Security<br />

Yes Yes Yes<br />

Number of user groups 50 50 50<br />

Passwords exportable No No No<br />

Number of user rights<br />

Data carrier support<br />

32 32 32<br />

<strong>PC</strong> card No No No<br />

CF card No No No<br />

Multimedia Card<br />

Recording<br />

No No No<br />

Recording/Printing<br />

Fonts<br />

- - -<br />

Keyboard fonts US American (English) US American (English) US American (English)<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/27<br />

2


2<br />

Operator panels<br />

Basic Panels<br />

Basic Panels – Standard<br />

■ Technical specifications (continued)<br />

Product type designation SIMATIC HMI KTP1000 Basic<br />

color DP<br />

Languages<br />

Configuration languages D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified", DK, FIN, GR, J,<br />

KP / ROK, NL, N, PL, P, RUS, S,<br />

CZ / SK, TR, H<br />

Character sets Tahoma, WinCC flexible Standard,<br />

symbol languages<br />

Transfer (upload/download)<br />

Transfer of configuration MPI/PROFIBUS DP, serial,<br />

automatic transfer recognition<br />

2/28<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified", DK, FIN, GR, J,<br />

KP / ROK, NL, N, PL, P, RUS, S,<br />

CZ / SK, TR, H<br />

Tahoma, WinCC flexible Standard,<br />

symbol languages<br />

Ethernet, automatic transfer recognition<br />

D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified", DK, FIN, GR, J,<br />

KP / ROK, NL, N, PL, P, RUS, S,<br />

CZ / SK, TR, H<br />

Tahoma, WinCC flexible Standard,<br />

symbol languages<br />

Ethernet, automatic transfer recognition<br />

Process coupling<br />

Connection to controller<br />

Expandability/openness<br />

see "System interfaces" from page 2/178<br />

Open Platform Program<br />

I/O<br />

No No No<br />

I/O devices<br />

Dimensions and weight<br />

Dimensions<br />

None None None<br />

Front of enclosure (W x H) 335 mm x 275 mm 335 mm x 275 mm 400 mm x 310 mm<br />

Mounting cutout/device depth<br />

(W x H)<br />

310 mm x 248 mm / 60 mm device<br />

depth<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV6 647-0AE11-3AX0 6AV6 647-0AF11-3AX0 6AV6 647-0AG11-3AX0<br />

SIMATIC HMI KTP1000 Basic<br />

color PN<br />

310 mm x 248 mm / 60 mm device<br />

depth<br />

Weight<br />

Weight 2.65 kg 2.65 kg 4.2 kg<br />

SIMATIC HMI TP1500 Basic<br />

color PN<br />

367 mm x 289 mm / 60 mm device<br />

depth


■ Ordering data Order No. Order No.<br />

SIMATIC HMI KP300 Basic<br />

mono PN<br />

A 6AV6 647-0AH11-3AX0<br />

SIMATIC HMI KTP400 Basic<br />

mono PN<br />

A 6AV6 647-0AA11-3AX0<br />

SIMATIC HMI KTP600 Basic<br />

mono PN<br />

A 6AV6 647-0AB11-3AX0<br />

SIMATIC HMI KTP600 Basic<br />

color DP<br />

A 6AV6 647-0AC11-3AX0<br />

SIMATIC HMI KTP600 Basic<br />

color PN<br />

A 6AV6 647-0AD11-3AX0<br />

SIMATIC HMI KTP1000 Basic<br />

color DP<br />

A 6AV6 647-0AE11-3AX0<br />

SIMATIC HMI KTP1000 Basic<br />

color PN<br />

A 6AV6 647-0AF11-3AX0<br />

SIMATIC HMI TP1500 Basic<br />

color PN<br />

A 6AV6 647-0AG11-3AX0<br />

Starter kit SIMATIC S7-1200 +<br />

KP300 Basic mono PN<br />

A 6AV6 651-7HA01-3AA1<br />

Starter kit SIMATIC S7-1200 +<br />

KTP400 Basic mono PN<br />

A 6AV6 651-7AA01-3AA1<br />

Starter kit SIMATIC S7-1200 +<br />

KTP600 Basic color PN<br />

Starter kits consist of:<br />

the respective SIMATIC HMI<br />

Basic Panel<br />

- SIMATIC HMI KP300 Basic<br />

mono PN<br />

- SIMATIC HMI KTP400 Basic<br />

mono PN<br />

- SIMATIC HMI KTP600 Basic<br />

color PN<br />

SIMATIC S7-1200 CPU 1212C<br />

AC/DC/Rly<br />

SIMATIC S7-1200 Simulator<br />

Module SIM 1274<br />

SIMATIC <strong>ST</strong>EP 7 BASIC CD<br />

SIMATIC S7-1200 HMI Manual<br />

Collection CD<br />

Ethernet CAT5 cable, 2 m<br />

A 6AV6 651-7DA01-3AA1<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Configuration<br />

All device versions:<br />

SIMATIC WinCC<br />

Basic/Comfort/Professional or<br />

SIMATIC <strong>ST</strong>EP 7 Basic (with<br />

integrated WinCC Basic)<br />

4"-15" device versions:<br />

SIMATIC WinCC flexible Compact<br />

Documentation<br />

(to be ordered separately)<br />

You can find the manual for the<br />

Basic Panels on the Internet at:<br />

Operator panels<br />

Basic Panels<br />

Basic Panels – Standard<br />

see HMI Software<br />

see HMI Software<br />

http://support.automation.<br />

siemens.com<br />

SIMATIC HMI Manual Collection B 6AV6 691-1SA01-0AX0<br />

Electronic documentation,<br />

on DVD<br />

5 languages (English, French,<br />

German, Italian and Spanish);<br />

contains: all currently available<br />

user manuals, manuals and<br />

communication manuals for<br />

SIMATIC HMI<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/29<br />

2


2<br />

Operator panels<br />

Basic Panels<br />

Basic Panels – Standard<br />

■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical specifications.<br />

KP300 Basic<br />

KTP400 Basic<br />

2/30<br />

148<br />

165<br />

122<br />

S SIMATIC PANEL<br />

140<br />

116<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

96.6<br />

28.9<br />

40<br />

81<br />

6.2 G_<strong>ST</strong><strong>80</strong>_XX_00462<br />

98<br />

6.2<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00355<br />

KTP600 Basic<br />

KTP1000 Basic<br />

196<br />

S SIMATIC PANEL<br />

S<br />

214<br />

309<br />

SIMATIC PANEL<br />

158<br />

275<br />

44<br />

140<br />

6.2<br />

247<br />

60.2 6.2<br />

335 G_<strong>ST</strong><strong>80</strong>_XX_00357<br />

G_<strong>ST</strong><strong>80</strong>_XX_00356


■ Dimensional drawings (continued)<br />

All specifications in mm. Panel cutout see technical<br />

specifications.<br />

TP1500 Basic<br />

366<br />

S SIMATIC PANEL<br />

400<br />

310<br />

288<br />

59.9 6.2<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00358<br />

Operator panels<br />

Basic Panels<br />

Basic Panels – Standard<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-basic-panels<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/31<br />

2


2<br />

Operator panels<br />

SIPLUS Basic Panels<br />

SIPLUS Basic Panels<br />

■ Overview<br />

1) ISA-S71.04 severity level GX: Long-term load: SO2 < 4.8 ppm;<br />

H2S < 9.9 ppm; Cl < 0.2 ppm; HCl < 0.66 ppm; HF < 0.12 ppm;<br />

NH < 49 ppm; O3 < 0.1 ppm; NOX < 5.2 ppm<br />

Limit value (max. 30 min/d): SO2 < 17.8 ppm; H2S < 49.7 ppm;<br />

Cl < 1.0 ppm; HCl < 3.3 ppm; HF < 2.4 ppm; NH < 247 ppm;<br />

O3


■ Ordering data Order No. Order No.<br />

SIPLUS HMI KTP400 Basic<br />

mono PN<br />

Extended ambient temperature<br />

range -10 ... + 60 °C. Suitable for<br />

areas with extraordinary medial<br />

exposure (conformal coating);<br />

ambient temperature<br />

-10 ... +60 °C<br />

A 6AG1 647-0AA11-2AX0<br />

SIPLUS HMI KTP 600 Basic<br />

color PN<br />

Extended ambient temperature<br />

range -25 ... + 60 °C. Suitable for<br />

areas with extraordinary medial<br />

exposure (conformal coating);<br />

ambient temperature<br />

-25 ... +60 °C<br />

A 6AG1 647-0AD11-2AX0<br />

SIPLUS HMI KTP 1000 Basic<br />

Color DP<br />

Suitable for areas with extraordinary<br />

medial exposure<br />

(conformal coating);<br />

ambient temperature 0 ... +50 °C<br />

A 6AG1 647-0AE11-4AX0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

SIPLUS Basic Panels<br />

SIPLUS Basic Panels<br />

SIPLUS HMI KTP 1000 Basic<br />

Color PN<br />

Suitable for areas with extraordinary<br />

medial exposure<br />

(conformal coating);<br />

ambient temperature 0 ... +50 °C<br />

A 6AG1 647-0AF11-4AX0<br />

SIPLUS HMI TP 1500 Basic<br />

Color PN<br />

Suitable for areas with extraordinary<br />

medial exposure<br />

(conformal coating);<br />

ambient temperature 0 ... +50 °C<br />

A 6AG1 647-0AG11-4AX0<br />

Accessories see SIMATIC Basic Panels<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/33<br />

2


2<br />

Operator panels<br />

Comfort Panels<br />

Comfort Panels – Standard<br />

■ Overview<br />

Excellent HMI functionality for demanding applications<br />

Widescreen TFT displays with 4.3", 7.0", 9.0" and 12.1"<br />

diagonals (all 16 million colors) with up to 40% more<br />

visualization area as compared to the predecessor devices<br />

Integrated high-end functionality with archives, scripts,<br />

PDF/Word/Excel viewer, Internet Explorer, Media Player<br />

Dimmable displays from 0 to 100% via PROFIenergy, via the<br />

HMI project or via a controller<br />

Up-to-date industrial design<br />

Upright installation for all touch devices<br />

Optimal selection option: four Touch and four Key versions are<br />

available<br />

Data security in the event of a power failure for the device and<br />

for the SIMATIC HMI Memory Card<br />

Innovative service and commissioning concept through<br />

second SD card (automatic backup)<br />

Easy project transfer via standard cable (standard Ethernet<br />

cable, standard USB cable)<br />

Maximum performance with short screen refresh times<br />

Suitable for harsh industrial environments thanks to extended<br />

approvals, such as Ex 2/22 and marine approval, cast<br />

aluminum fronts for 7" upwards<br />

Wide range of communication options: PROFIBUS and<br />

PROFINET onboard, with 7" and above, 2 x PROFINET with<br />

integrated switch<br />

Key-operated devices with LED in every function key and new<br />

text input mechanism, similar to the keypads of mobile phones<br />

Key-operated devices with stamped keys for optimum tactile<br />

feedback<br />

All keys have a service life of 2 million operations<br />

Configuring with the WinCC engineering software of the<br />

TIA Portal<br />

2/34<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Integral component of Totally Integrated Automation (TIA):<br />

Increased productivity, minimum engineering overhead,<br />

reduction in life-cycle costs<br />

- Can also be used in a vertical position where installation<br />

space is restricted (all touch devices)<br />

Reduction of service and commissioning costs due to:<br />

- Short configuring and commissioning times through efficient<br />

engineering and fast project downloading<br />

- Automatic backup via optional SIMATIC HMI memory card<br />

- Long service life of the backlighting<br />

- Maintenance-free design<br />

- Data security in the event of power failure<br />

Simple and user-friendly representation of process values<br />

thanks to, for example, input/output fields, graphics, trend<br />

curves, bar charts, text and bitmaps<br />

Graphic library is available with preconfigured screen objects<br />

Can be used worldwide:<br />

- 32 online languages (incl. Asian and Cyrillic character sets)<br />

can be configured<br />

- Up to 32 languages can be switched online<br />

- Language-dependent texts and graphics<br />

Standard hardware and software interfaces for increasing<br />

flexibility and for saving on additional hardware:<br />

- PROFIBUS and PROFINET onboard (with 7" and above, two<br />

PROFINET ports with integrated switch)<br />

- Two SD card slots for storing archives, user data and for<br />

automatic backup<br />

- USB device interface for easy downloading of projects<br />

- USB host interfaces for connecting USB flash drive,<br />

keyboard, mouse and printer<br />

- With 7" and above, audio in/out interface for use with the<br />

integrated media player<br />

- Standard Windows storage formats (CSV) for archives and<br />

recipes permit further processing with standard tools<br />

(e.g. Microsoft Excel)<br />

- Modular expansion capability with the Sm@rtServer option<br />

for communication between various SIMATIC HMI systems<br />

and for remote maintenance<br />

■ Application<br />

The SIMATIC HMI Comfort Panels can be used wherever<br />

machines and plants are controlled and monitored locally - in<br />

production, process and building automation alike. They may be<br />

used in all kinds of industries and applications. They are ideally<br />

suited to demanding visualization tasks, and due to the<br />

integrated functionality, the right device can be selected for<br />

every application.


■ Design<br />

KTP400 Comfort<br />

4.3" widescreen TFT display, resolution 4<strong>80</strong> x 272, 16 million<br />

colors<br />

1 PROFINET and 1 PROFIBUS interface<br />

Touch screen and membrane keyboard with 4 tactile function<br />

keys<br />

KP400 Comfort<br />

4.3" widescreen TFT display, resolution 4<strong>80</strong> x 272, 16 million<br />

colors<br />

1 PROFINET and 1 PROFIBUS interface<br />

Membrane keyboard with 8 tactile function keys and system<br />

keyboard<br />

TP700 Comfort<br />

7.0" widescreen TFT display, resolution <strong>80</strong>0 x 4<strong>80</strong>, 16 million<br />

colors<br />

1 PROFINET (2 ports with integrated switch) and 1 PROFIBUS<br />

interface<br />

Touch screen<br />

KP700 Comfort<br />

7.0" widescreen TFT display, resolution <strong>80</strong>0 x 4<strong>80</strong>, 16 million<br />

colors<br />

1 PROFINET (2 ports with integrated switch) and 1 PROFIBUS<br />

interface<br />

Membrane keyboard with 24 function keys and system<br />

keyboard<br />

TP900 Comfort<br />

9.0" widescreen TFT display, resolution <strong>80</strong>0 x 4<strong>80</strong>, 16 million<br />

colors<br />

1 PROFINET (2 ports with integrated switch) and 1 PROFIBUS<br />

interface<br />

Touch screen<br />

KP900 Comfort<br />

9.0" widescreen TFT display, resolution <strong>80</strong>0 x 4<strong>80</strong>, 16 million<br />

colors<br />

1 PROFINET (2 ports with integrated switch) and 1 PROFIBUS<br />

interface<br />

Membrane keyboard with 26 function keys and system<br />

keyboard<br />

TP1200 Comfort<br />

12.1" widescreen TFT display, resolution 12<strong>80</strong> x <strong>80</strong>0, 16 million<br />

colors<br />

1 PROFINET (2 ports with integrated switch) and 1 PROFIBUS<br />

interface<br />

Touch screen<br />

KP1200 Comfort<br />

12.1" widescreen TFT display, resolution <strong>80</strong>0 x 4<strong>80</strong>, 16 million<br />

colors<br />

1 PROFINET (2 ports with integrated switch) and 1 PROFIBUS<br />

interface<br />

Membrane keyboard with 34 function keys and system<br />

keyboard<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Comfort Panels<br />

Comfort Panels – Standard<br />

■ Function<br />

Display and changing of process parameters<br />

Function keys are used for directly triggering functions and<br />

actions in the key-operated devices and with KTP400. Up to<br />

16 functions can be configured simultaneously on function<br />

keys. The function keys can also be used direct as<br />

PROFIBUS DP or PROFINET IO input I/O.<br />

Process display:<br />

- Vector graphic (various line and plane objects)<br />

- Dynamic positioning and dynamic showing/hiding of objects<br />

- Fully-graphical displays, plots, and bar graph display<br />

- Display of up to 8 trends per trend field; trend curve graphic<br />

with scroll and zoom functions for accessing the history and<br />

flexible selection of the representation period; read ruler for<br />

determining current values and display in a table<br />

- Comprehensive graphic libraries (SIMATIC HMI Symbol<br />

Library)<br />

- Icons: slider, gauge, clock<br />

- Cyclic function processing by alarm clock<br />

Multiplex function for variables<br />

Signaling system<br />

- Discrete alarms and analog alarms (limit alarms)<br />

- Freely-definable message classes (e. g. status/fault<br />

messages) for definition of acknowledgment response and<br />

display of message events<br />

- Status and fault messages with message history<br />

- Preconfigured message screen, message window, and<br />

message line<br />

Archiving of messages and process values (on SD/multimedia<br />

card/USB flash drive, etc. or network drives via Ethernet)<br />

- Various archive types: Circulating and sequence archive<br />

- Storage of archive data in standard Windows format (CSV)<br />

- Online evaluation of process value archives using trend<br />

curves<br />

- External evaluation using standard tools (MS Excel,<br />

MS Access) is possible<br />

Alarm log and shift log<br />

Print functions (see "Recommended printers")<br />

Language change<br />

- 32 online languages, 32 configuration languages including<br />

Asian and Cyrillic character sets<br />

Recipe management<br />

- With additional data storage (on SD/multimedia card/USB<br />

flash drive, etc.)<br />

- Online/offline processing on the panel<br />

- Storage of recipe data in standard Windows format (CSV)<br />

- External processing using standard tools (MS Excel,<br />

MS Access) is possible<br />

PG functionality <strong>ST</strong>ATUS/FORCE VAR in combination with<br />

SIMATIC S7<br />

Diagnostics display in combination with SIMATIC S7 supports<br />

fast troubleshooting<br />

Screen selection from PLC permits operator control from the<br />

PLC<br />

Display of HTML documents using MS Internet Explorer<br />

Visual Basic Script offers flexibility through implementing new<br />

functions incl. interfacing to tags (comparison operations,<br />

loop-through, etc.)<br />

Help texts for process pictures, alarms, and tags<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/35<br />

2


2<br />

Operator panels<br />

Comfort Panels<br />

Comfort Panels – Standard<br />

■ Function (continued)<br />

Arithmetic functions<br />

Limit value monitoring for reliable process control of inputs<br />

and outputs<br />

Configuration<br />

The configuration is implemented using the engineering<br />

software SIMATIC WinCC Comfort (TIA Portal).<br />

2/36<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Integration<br />

The SIMATIC HMI Comfort Panels can be connected to:<br />

SIMATIC S7 controllers<br />

Third-party controllers<br />

- Allen Bradley DF1, Allen Bradley EtherNet/IP<br />

- Modicon MODBUS RTU, Modicon MODBUS TCP/IP<br />

- Mitsubishi FX, Mitsubishi MC TCP/IP<br />

- Omron Hostlink/Multilink<br />

Multi-protocol capability<br />

http communication with other SIMATIC HMI systems<br />

Over Ethernet (TCP/IP) to a higher-level <strong>PC</strong>, network printer<br />

Note:<br />

Further information can be found under "System interfaces".


■ Technical specifications<br />

Operator panels<br />

Comfort Panels<br />

Comfort Panels – Standard<br />

6AV2 124-2DC01-0AX0 6AV2 124-0GC01-0AX0 6AV2 124-0JC01-0AX0 6AV2 124-0MC01-0AX0<br />

Product type designation<br />

Display<br />

Display type<br />

KTP400 Comfort TP700 Comfort TP900 Comfort TP1200 Comfort<br />

Resolution (WxH in pixel)<br />

Control elements<br />

4<strong>80</strong> x 272 <strong>80</strong>0 x 4<strong>80</strong> <strong>80</strong>0 x 4<strong>80</strong><br />

Control elements Touch screen Touch screen Touch screen<br />

Connection for<br />

mouse/keyboard/barcode<br />

reader<br />

USB / USB / USB USB / USB / USB USB / USB / USB USB / USB / USB<br />

Keyboard<br />

System keys 0<br />

Numeric/alphabetical input<br />

Touch operation<br />

Yes / Yes Yes / Yes Yes / Yes Yes / Yes<br />

Touch screen<br />

Supply voltage<br />

analog, resistive analog, resistive analog, resistive analog, resistive<br />

Supply voltage 24 V DC 24 V DC 24 V DC 24 V DC<br />

Rated current<br />

Memory<br />

0.13 A 0.5 A 0.75 A 0.85 A<br />

Type Flash / RAM Flash / RAM Flash / RAM Flash / RAM<br />

Usable memory for user data<br />

Type of output<br />

4 MB usable memory for<br />

user data<br />

Acoustics Buzzer<br />

Time of day<br />

Clock<br />

Type Hardware clock, battery<br />

backup, synchronizable<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Hardware clock, battery<br />

backup, synchronizable<br />

Hardware clock, battery<br />

backup, synchronizable<br />

Hardware clock, battery<br />

backup, synchronizable<br />

Interfaces<br />

Multimedia card<br />

Industrial Ethernet interface<br />

Protocols<br />

Protocols (terminal link)<br />

1 x Ethernet (RJ45) 2 x Ethernet (RJ45) 2 x Ethernet (RJ45) 2 x Ethernet (RJ45)<br />

Sm@rtAccess<br />

EMC<br />

Emission of radio interference<br />

acc. to EN 55 011<br />

Yes Yes Yes Yes<br />

Emission of radio interferences<br />

acc. to EN 55 011<br />

(limit class A)<br />

Ambient conditions<br />

Yes<br />

Operation (vertical<br />

installation)<br />

0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °C<br />

Operation (max. tilt angle) 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C<br />

Transport, storage -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C<br />

max. relative humidity 90 % 90 % 90 % 90 %<br />

Mounting position vertical vertical vertical vertical<br />

maximum permissible angle<br />

of inclination without external<br />

ventilation<br />

+/- 35 ° +/- 35 ° +/- 35 ° +/- 35 °<br />

Front IP65 IP65 IP65 IP65<br />

Rear IP20 IP20 IP20 IP20<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/37<br />

2


2<br />

Operator panels<br />

Comfort Panels<br />

Comfort Panels – Standard<br />

■ Technical specifications (continued)<br />

Operating systems<br />

Operating system<br />

Functionality under<br />

WinCC flexible /<br />

WinCC (TIA Portal)<br />

Windows CE Windows CE Windows CE Windows CE<br />

Applications/options see chapter 4: HMI software/SIMATIC WinCC flexible options and SIMATIC WinCC (TIA portal) options<br />

Number of Visual Basic<br />

Scripts<br />

50 100 100 100<br />

Task planner Yes Yes Yes Yes<br />

Help system Yes Yes Yes Yes<br />

Status/control<br />

With alarm logging system<br />

(incl. buffer and<br />

acknowledgment)<br />

with SIMATIC S7 with SIMATIC S7 with SIMATIC S7 with SIMATIC S7<br />

Number of messages 2000 4 000 4000 4000<br />

Bit messages Yes Yes Yes Yes<br />

Analog messages Yes Yes Yes Yes<br />

Message buffer Ring buffer<br />

(n x 256 entries), retentive,<br />

maintenance-free<br />

2/38<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Ring buffer<br />

(n x 1024 entries),<br />

retentive, maintenance-free<br />

Ring buffer<br />

(n x 1024 entries),<br />

retentive, maintenance-free<br />

Ring buffer<br />

(n x 1024 entries),<br />

retentive, maintenance-free<br />

Recipes<br />

Recipes 100 300 300 300<br />

Data records per recipe 200 500 500 500<br />

Entries per data record<br />

Number of process images<br />

200 1000 1000 1000<br />

Process images 500 500 500 500<br />

Variables 1024 2 048 2048 2048<br />

Limit values Yes Yes Yes Yes<br />

Multiplexing<br />

Image elements<br />

Yes Yes Yes Yes<br />

Text objects 2,500 text elements<br />

Graphic object Bit maps, icons, vector Bit maps, icons, vector Bit maps, icons, vector Bit maps, icons, vector<br />

graphics<br />

graphics<br />

graphics<br />

graphics<br />

dynamic objects Diagrams, bar graphs,<br />

sliders, analog display,<br />

invisible buttons<br />

Diagrams, bar graphs,<br />

sliders, analog display,<br />

invisible buttons<br />

Diagrams, bar graphs,<br />

sliders, analog display,<br />

invisible buttons<br />

Diagrams, bar graphs,<br />

sliders, analog display,<br />

invisible buttons<br />

Lists<br />

Text lists 300 500 500 500<br />

Graphic list 100 500 500 500<br />

Libraries<br />

Archiving<br />

Yes Yes Yes Yes<br />

Number of archives per<br />

project<br />

10 50 50 50<br />

Number of measuring<br />

points per project<br />

100 2 048 2048 2048<br />

Number of entries per<br />

archive<br />

10 000 20 000 20 000 20 000<br />

Data storage format CSV file, readable, e.g. with CSV file, readable, e.g. with CSV file, readable, e.g. with CSV file, readable, e.g. with<br />

MS Excel, MS Access MS Excel, MS Access MS Excel, MS Access MS Excel, MS Access<br />

external evaluation Can be read, e.g., in MS Can be read, e.g., in MS Can be read, e.g., in MS Can be read, e.g., in MS<br />

Excel, MS Access, etc. Excel, MS Access, etc. Excel, MS Access, etc. Excel, MS Access, etc.<br />

Size of archive Depending on free memory<br />

on ext. card/stick or on free<br />

hard disk memory via<br />

network drive<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV2 124-2DC01-0AX0 6AV2 124-0GC01-0AX0 6AV2 124-0JC01-0AX0 6AV2 124-0MC01-0AX0<br />

Product type designation KTP400 Comfort TP700 Comfort TP900 Comfort TP1200 Comfort<br />

Depending on free memory<br />

on ext. card/stick or on free<br />

hard disk memory via<br />

network drive<br />

Depending on free memory<br />

on ext. card/stick or on free<br />

hard disk memory via<br />

network drive<br />

Depending on free memory<br />

on ext. card/stick or on free<br />

hard disk memory via<br />

network drive<br />

Online evaluation Using trend curves Using trend curves Using trend curves Using trend curves


© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Comfort Panels<br />

Comfort Panels – Standard<br />

■ Technical specifications (continued)<br />

6AV2 124-2DC01-0AX0 6AV2 124-0GC01-0AX0 6AV2 124-0JC01-0AX0 6AV2 124-0MC01-0AX0<br />

Product type designation<br />

Security<br />

KTP400 Comfort TP700 Comfort TP900 Comfort TP1200 Comfort<br />

Number of user groups 50 50 50 50<br />

Passwords exportable Yes Yes Yes Yes<br />

Number of user rights<br />

Data carrier support<br />

32 32 32 32<br />

<strong>PC</strong> card No No No No<br />

CF card No No No No<br />

Multi Media Card<br />

Recording<br />

Yes Yes Yes Yes<br />

Recording/Printing Alarms, report (shift report), Alarms, report (shift report), Alarms, report (shift report), Alarms, report (shift report),<br />

color print, hardcopy color print, hardcopy color print, hardcopy color print, hardcopy<br />

Printer driver<br />

Fonts<br />

ESC/P2, <strong>PC</strong>L3/<strong>PC</strong>L6 ESC/P2, <strong>PC</strong>L3/<strong>PC</strong>L6 ESC/P2, <strong>PC</strong>L3/<strong>PC</strong>L6 ESC/P2, <strong>PC</strong>L3/<strong>PC</strong>L6<br />

Keyboard fonts<br />

Languages<br />

US American (English) US American (English) US American (English) US American (English)<br />

Online languages 16 32 32 32<br />

Configuration languages D, GB, F, I, E, CHN "tradi- D, GB, F, I, E, CHN "tradi- D, GB, F, I, E, CHN "tradi- D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified", tional", CHN "simplified", tional", CHN "simplified", tional", CHN "simplified",<br />

DK, FIN, GR, J, KP / ROK, DK, FIN, GR, J, KP / ROK, DK, FIN, GR, J, KP / ROK, DK, FIN, GR, J, KP / ROK,<br />

NL, N, PL, P, RUS, S, CZ / NL, N, PL, P, RUS, S, CZ / NL, N, PL, P, RUS, S, CZ / NL, N, PL, P, RUS, S, CZ /<br />

SK, TR, H<br />

SK, TR, H<br />

SK, TR, H<br />

SK, TR, H<br />

Character sets Tahoma, Arial, Courier Tahoma, Arial, Courier Tahoma, Arial, Courier Tahoma, Arial, Courier<br />

New, symbol languages, New, symbol languages, New, symbol languages, New, symbol languages,<br />

4 additional character sets 4 additional character sets 4 additional character sets 4 additional character sets<br />

can be loaded, all freely can be loaded, all freely can be loaded, all freely can be loaded, all freely<br />

Transfer (upload/download)<br />

scalable<br />

scalable<br />

scalable<br />

scalable<br />

Transfer of configuration MPI/PROFIBUS DP, USB, MPI/PROFIBUS DP, USB, MPI/PROFIBUS DP, USB, MPI/PROFIBUS DP, USB,<br />

Ethernet, automatic transfer Ethernet, automatic transfer Ethernet, automatic transfer Ethernet, automatic transfer<br />

I/O<br />

recognition<br />

recognition<br />

recognition<br />

recognition<br />

I/O devices<br />

Dimensions and weight<br />

Printer, barcode reader Printer, barcode reader Printer, barcode reader Printer, barcode reader<br />

Front of enclosure (W x H)<br />

Weight<br />

140 mm x 116 mm 214 mm x 158 mm<br />

Weight 0.6 kg 1.4 kg 1.9 kg 2.8 kg<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/39<br />

2


2<br />

Operator panels<br />

Comfort Panels<br />

Comfort Panels – Standard<br />

■ Technical specifications (continued)<br />

6AV2 124-1DC01-0AX0 6AV2 124-1GC01-0AX0 6AV2 124-1JC01-0AX0 6AV2 124-1MC01-0AX0<br />

Product type designation<br />

Display<br />

Display type<br />

KP400 Comfort KP700 Comfort KP900 Comfort KP1200 Comfort<br />

Resolution (WxH in pixel)<br />

Control elements<br />

4<strong>80</strong> x 272 <strong>80</strong>0 x 4<strong>80</strong> <strong>80</strong>0 x 4<strong>80</strong><br />

Control elements Membrane keyboard Membrane keyboard Membrane keyboard Membrane keyboard<br />

Connection for<br />

mouse/keyboard/barcode<br />

reader<br />

USB / USB / USB USB / USB / USB USB / USB / USB USB / USB / USB<br />

Keyboard<br />

System keys 28 28 28 28<br />

Numeric/alphabetical input<br />

Touch operation<br />

Yes / Yes Yes / Yes Yes / Yes Yes / Yes<br />

Touch screen<br />

Supply voltage<br />

No No No No<br />

Supply voltage 24 V DC 24 V DC 24 V DC 24 V DC<br />

Rated current<br />

Memory<br />

0.13 A 0.5 A 0.75 A 0.85 A<br />

Type Flash / RAM Flash / RAM Flash / RAM Flash / RAM<br />

Usable memory for user data<br />

Type of output<br />

4 MB usable memory for<br />

user data<br />

Acoustics Buzzer<br />

Time of day<br />

Clock<br />

Type Hardware clock, battery<br />

backup, synchronizable<br />

2/40<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Hardware clock, battery<br />

backup, synchronizable<br />

Hardware clock, battery<br />

backup, synchronizable<br />

Hardware clock, battery<br />

backup, synchronizable<br />

Interfaces<br />

Multimedia card<br />

Industrial Ethernet interface<br />

Protocols<br />

Protocols (terminal link)<br />

1 x Ethernet (RJ45) 2 x Ethernet (RJ45) 2 x Ethernet (RJ45) 2 x Ethernet (RJ45)<br />

Sm@rtAccess<br />

Ambient conditions<br />

Yes Yes Yes Yes<br />

Operation (vertical<br />

installation)<br />

0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °C<br />

Operation (max. tilt angle) 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C<br />

Transport, storage -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C<br />

max. relative humidity 90 % 90 % 90 % 90 %<br />

Mounting position vertical vertical vertical vertical<br />

maximum permissible angle<br />

of inclination without external<br />

ventilation<br />

+/- 35 ° +/- 35 ° +/- 35 ° +/- 35 °<br />

Front IP65 IP65 IP65 IP65<br />

Rear<br />

Operating systems<br />

IP20 IP20 IP20 IP20<br />

Operating system Windows CE Windows CE Windows CE Windows CE


■ Technical specifications (continued)<br />

Operator panels<br />

Comfort Panels<br />

Comfort Panels – Standard<br />

Functionality under<br />

WinCC flexible /<br />

WinCC (TIA Portal)<br />

Applications/options see chapter 4: HMI software/SIMATIC WinCC flexible options and SIMATIC WinCC (TIA portal) options<br />

Number of Visual Basic<br />

Scripts<br />

50 100 100 100<br />

Task planner Yes Yes Yes Yes<br />

Help system Yes Yes Yes Yes<br />

Status/control<br />

With alarm logging system<br />

(incl. buffer and<br />

acknowledgment)<br />

with SIMATIC S7 with SIMATIC S7 with SIMATIC S7 with SIMATIC S7<br />

Number of messages 2000 4 000 4000 4000<br />

Bit messages Yes Yes Yes Yes<br />

Analog messages Yes Yes Yes Yes<br />

Message buffer Ring buffer<br />

(n x 256 entries), retentive,<br />

maintenance-free<br />

Ring buffer<br />

(n x 1024 entries),<br />

retentive, maintenance-free<br />

Ring buffer<br />

(n x 1024 entries),<br />

retentive, maintenance-free<br />

Ring buffer<br />

(n x 1024 entries),<br />

retentive, maintenance-free<br />

Recipes<br />

Recipes 100 300 300 300<br />

Data records per recipe 200 500 500 500<br />

Entries per data record<br />

Number of process images<br />

200 1000 1000 1000<br />

Process images 500 500 500 500<br />

Variables 1024 2 048 2048 2048<br />

Limit values Yes Yes Yes Yes<br />

Multiplexing<br />

Image elements<br />

Yes Yes Yes Yes<br />

Text objects 2,500 text elements<br />

Graphic object Bit maps, icons, vector Bit maps, icons, vector Bit maps, icons, vector Bit maps, icons, vector<br />

graphics<br />

graphics<br />

graphics<br />

graphics<br />

dynamic objects Diagrams, bar graphs,<br />

sliders, analog display,<br />

invisible buttons<br />

Diagrams, bar graphs,<br />

sliders, analog display,<br />

invisible buttons<br />

Diagrams, bar graphs,<br />

sliders, analog display,<br />

invisible buttons<br />

Diagrams, bar graphs,<br />

sliders, analog display,<br />

invisible buttons<br />

Lists<br />

Text lists 300 500 500 500<br />

Graphic list 100 500 500 500<br />

Libraries<br />

Archiving<br />

Yes Yes Yes Yes<br />

Number of archives per<br />

project<br />

10 50 50 50<br />

Number of measuring<br />

points per project<br />

100 2 048 2048 2048<br />

Number of entries per<br />

archive<br />

10 000 20 000 20 000 20 000<br />

Data storage format CSV file, readable, e.g. with CSV file, readable, e.g. with CSV file, readable, e.g. with CSV file, readable, e.g. with<br />

MS Excel, MS Access MS Excel, MS Access MS Excel, MS Access MS Excel, MS Access<br />

external evaluation Can be read, e.g., in MS Can be read, e.g., in MS Can be read, e.g., in MS Can be read, e.g., in MS<br />

Excel, MS Access, etc. Excel, MS Access, etc. Excel, MS Access, etc. Excel, MS Access, etc.<br />

Size of archive Depending on free memory<br />

on ext. card/stick or on free<br />

hard disk memory via<br />

network drive<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV2 124-1DC01-0AX0 6AV2 124-1GC01-0AX0 6AV2 124-1JC01-0AX0 6AV2 124-1MC01-0AX0<br />

Product type designation KP400 Comfort KP700 Comfort KP900 Comfort KP1200 Comfort<br />

Depending on free memory<br />

on ext. card/stick or on free<br />

hard disk memory via<br />

network drive<br />

Depending on free memory<br />

on ext. card/stick or on free<br />

hard disk memory via<br />

network drive<br />

Depending on free memory<br />

on ext. card/stick or on free<br />

hard disk memory via<br />

network drive<br />

Online evaluation Using trend curves Using trend curves Using trend curves Using trend curves<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/41<br />

2


2<br />

Operator panels<br />

Comfort Panels<br />

Comfort Panels – Standard<br />

■ Technical specifications (continued)<br />

6AV2 124-1DC01-0AX0 6AV2 124-1GC01-0AX0 6AV2 124-1JC01-0AX0 6AV2 124-1MC01-0AX0<br />

Product type designation<br />

Security<br />

KP400 Comfort KP700 Comfort KP900 Comfort KP1200 Comfort<br />

Number of user groups 50 50 50 50<br />

Passwords exportable Yes Yes Yes Yes<br />

Number of user rights<br />

Data carrier support<br />

32 32 32 32<br />

<strong>PC</strong> card No No No No<br />

CF card No No No No<br />

Multi Media Card<br />

Recording<br />

Yes Yes Yes Yes<br />

Recording/Printing Alarms, report (shift report), Alarms, report (shift report), Alarms, report (shift report), Alarms, report (shift report),<br />

color print, hardcopy color print, hardcopy color print, hardcopy color print, hardcopy<br />

Printer driver<br />

Fonts<br />

ESC/P2, <strong>PC</strong>L3/<strong>PC</strong>L6 ESC/P2, <strong>PC</strong>L3/<strong>PC</strong>L6 ESC/P2, <strong>PC</strong>L3/<strong>PC</strong>L6 ESC/P2, <strong>PC</strong>L3/<strong>PC</strong>L6<br />

Keyboard fonts<br />

Languages<br />

US American (English) US American (English) US American (English) US American (English)<br />

Online languages 32 32 32 32<br />

Configuration languages D, GB, F, I, E, CHN "tradi- D, GB, F, I, E, CHN "tradi- D, GB, F, I, E, CHN "tradi- D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified", tional", CHN "simplified", tional", CHN "simplified", tional", CHN "simplified",<br />

DK, FIN, GR, J, KP / ROK, DK, FIN, GR, J, KP / ROK, DK, FIN, GR, J, KP / ROK, DK, FIN, GR, J, KP / ROK,<br />

NL, N, PL, P, RUS, S, CZ / NL, N, PL, P, RUS, S, CZ / NL, N, PL, P, RUS, S, CZ / NL, N, PL, P, RUS, S, CZ /<br />

SK, TR, H<br />

SK, TR, H<br />

SK, TR, H<br />

SK, TR, H<br />

Character sets Tahoma, Arial, Courier Tahoma, Arial, Courier Tahoma, Arial, Courier Tahoma, Arial, Courier<br />

New, symbol languages, New, symbol languages, New, symbol languages, New, symbol languages,<br />

4 additional character sets 4 additional character sets 4 additional character sets 4 additional character sets<br />

can be loaded, all freely can be loaded, all freely can be loaded, all freely can be loaded, all freely<br />

Transfer (upload/download)<br />

scalable<br />

scalable<br />

scalable<br />

scalable<br />

Transfer of configuration MPI/PROFIBUS DP, USB, MPI/PROFIBUS DP, USB, MPI/PROFIBUS DP, USB, MPI/PROFIBUS DP, USB,<br />

Ethernet, automatic transfer Ethernet, automatic transfer Ethernet, automatic transfer Ethernet, automatic transfer<br />

I/O<br />

recognition<br />

recognition<br />

recognition<br />

recognition<br />

I/O devices<br />

Dimensions and weight<br />

Printer, barcode reader Printer, barcode reader Printer, barcode reader Printer, barcode reader<br />

Front of enclosure (W x H)<br />

Weight<br />

308 mm x 204 mm<br />

Weight 0.8 kg 2.2 kg 2.7 kg 4.4 kg<br />

2/42<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Ordering data Order No. Order No.<br />

SIMATIC HMI Comfort Panels,<br />

Touch<br />

SIMATIC HMI KTP400 Comfort, E<br />

Key and Touch<br />

6AV2 124-2DC01-0AX0<br />

SIMATIC HMI TP700 Comfort E 6AV2 124-0GC01-0AX0<br />

SIMATIC HMI TP900 Comfort E 6AV2 124-0JC01-0AX0<br />

SIMATIC HMI TP1200 Comfort<br />

SIMATIC HMI Comfort Panels,<br />

Key<br />

E 6AV2 124-0MC01-0AX0<br />

SIMATIC HMI KP400 Comfort,<br />

Key<br />

E 6AV2 124-1DC01-0AX0<br />

SIMATIC HMI KP700 Comfort,<br />

Key<br />

E 6AV2 124-1GC01-0AX0<br />

SIMATIC HMI KP900 Comfort,<br />

Key<br />

E 6AV2 124-1JC01-0AX0<br />

SIMATIC HMI KP1200 Comfort,<br />

Key<br />

E 6AV2 124-1MC01-0AX0<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Starter kits for HMI Comfort<br />

Panels<br />

Consisting of:<br />

The respective HMI Comfort<br />

Panel SIMATIC WinCC Comfort<br />

SIMATIC HMI Manual Collection<br />

(DVD), 5 languages<br />

Ethernet cable, 2 m<br />

SIMATIC HMI memory card 2 GB<br />

10 protective membranes for<br />

touch screen devices<br />

Starter kit for HMI KTP400<br />

Comfort, Key and Touch<br />

Starter kit for HMI TP700<br />

Comfort<br />

Starter kit for HMI TP900<br />

Comfort<br />

Starter kit for HMI TP1200<br />

Comfort<br />

Starter kit for HMI KP400<br />

Comfort, Key<br />

Starter kit for HMI KP700<br />

Comfort, Key<br />

Starter kit for HMI KP900<br />

Comfort, Key<br />

Starter kit for HMI KP1200<br />

Comfort, Key<br />

Operator panels<br />

Comfort Panels<br />

Comfort Panels – Standard<br />

E 6AV2 181-4DB20-0AX0<br />

E 6AV2 181-4GB00-0AX0<br />

E 6AV2 181-4JB00-0AX0<br />

E 6AV2 181-4MB00-0AX0<br />

E 6AV2 181-4DB10-0AX0<br />

E 6AV2 181-4GB10-0AX0<br />

E 6AV2 181-4JB10-0AX0<br />

E 6AV2 181-4MB10-0AX0<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/43<br />

2


2<br />

Operator panels<br />

Comfort Panels<br />

Comfort Panels – Standard<br />

■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical specifications.<br />

KP400 Comfort<br />

KP700 Comfort<br />

2/44<br />

152<br />

134<br />

308<br />

2<strong>80</strong><br />

194.7<br />

188<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

204<br />

170<br />

98<br />

176<br />

138.8<br />

18<br />

48<br />

55.8<br />

32.5<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

62.8<br />

69<br />

G_<strong>ST</strong><strong>80</strong>_XX_00444<br />

G_<strong>ST</strong><strong>80</strong>_XX_00445<br />

KP900 Comfort<br />

KP1200 Comfort<br />

362<br />

336<br />

194.7<br />

454<br />

432<br />

194.7<br />

230<br />

289<br />

204<br />

138.8<br />

32.5<br />

267<br />

32.5<br />

138.8<br />

62.8<br />

69<br />

64.5<br />

70.5<br />

G_<strong>ST</strong><strong>80</strong>_XX_00446<br />

G_<strong>ST</strong><strong>80</strong>_XX_00447


■ Dimensional drawings (continued)<br />

KTP400 Comfort<br />

TP700 Comfort<br />

140<br />

122<br />

214<br />

196<br />

116<br />

158<br />

98<br />

140<br />

18<br />

32.5<br />

48.6<br />

54.8<br />

62.8<br />

69<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00448<br />

G_<strong>ST</strong><strong>80</strong>_XX_00449<br />

TP900 Comfort<br />

TP1200 Comfort<br />

274<br />

249<br />

194.7<br />

330<br />

308<br />

194.7<br />

Operator panels<br />

Comfort Panels<br />

Comfort Panels – Standard<br />

190<br />

241<br />

164<br />

138.8<br />

219<br />

138.8<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

32.5<br />

63.1<br />

69.3<br />

32.5<br />

64.3<br />

70.5<br />

G_<strong>ST</strong><strong>80</strong>_XX_00450<br />

G_<strong>ST</strong><strong>80</strong>_XX_00451<br />

2/45<br />

2


2<br />

Operator panels<br />

Comfort Panels<br />

Comfort Panels – Standard<br />

■ More information<br />

Further information can be found on the Internet at:<br />

www.siemens.com/simatic-comfort-panels<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation..<br />

2/46<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Overview<br />

SIMATIC Mobile Panel<br />

Mobile operator panel for direct operator control of the plant<br />

and machine from any point<br />

Supports an optimum view of the workpiece or process and,<br />

at the same time, direct access and visual contact with the<br />

operator panel<br />

Versatile use thanks to easy unplugging and replugging<br />

during normal operation (Mobile Panel 177 and<br />

Mobile Panel 277) or<br />

Wireless freedom (Mobile Panel 277(F) IWLAN)<br />

Pixel-graphics, high-luminance color display with touch<br />

screen (analog/resistive)<br />

PROFIBUS or PROFINET communication, PROFINET over<br />

WLAN for Mobile Panel 277(F) IWLAN<br />

Freely-configurable function keys with customized labels<br />

(with LED) (not for Mobile Panel 277 10")<br />

SIMATIC Mobile Panel 177 and SIMATIC Mobile Panel 277<br />

Two three-stage acknowledgement buttons;<br />

Optional versions include:<br />

- <strong>ST</strong>OP pushbutton<br />

- <strong>ST</strong>OP button, handwheel, key-operated switch and<br />

illuminated pushbutton (not for Mobile Panel 277 10")<br />

Communication is supported via a serial link, MPI/PROFIBUS<br />

or PROFINET<br />

Connection point recognition for local identification of the<br />

device based on the connection point ID<br />

Fast system availability after plugging into the terminal boxes<br />

Connection to the controller and power supply is made via the<br />

terminal box and the connecting cable<br />

SIMATIC Mobile Panel 277(F) IWLAN<br />

Wireless, mobile operator panel for flexible and locationindependent<br />

system and machine operation<br />

WLAN communication in accordance with IEEE <strong>80</strong>2.11 a (b/g)<br />

and support of PROFINET<br />

Powerful batteries and flexible concept for changing permit<br />

battery replacement "on the fly" without interrupting operation<br />

Effective range limitation and the local identification of the<br />

device by using transponder technology<br />

Low-cost, safety-related mobile operator control and<br />

monitoring via RFID technology (MOBY D) for plants with preinstalled<br />

safety resources (e.g. robot cells)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Mobile Panels<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Mobile Panels<br />

Optional versions with: Handwheel, key switch and illuminated<br />

pushbutton<br />

Fail-safe operator controls of the SIMATIC Mobile Panel<br />

277F IWLAN using PROFIsafe:<br />

- Two three-stage acknowledgment buttons<br />

- Emergency stop button<br />

IWLAN Access Points SCALANCE W for SIMATIC Mobile<br />

Panel 277(F) IWLAN<br />

The Access Points of the product line SCALANCE W-7<strong>80</strong> are<br />

ideally suited for setting up Industrial Wireless LAN (IWLAN)<br />

radio networks for 2.4 GHz and 5 GHz with data rates of up to<br />

54 Mbit/s; they can be used for all applications that require a<br />

high degree of operational reliability, even under extremely<br />

harsh ambient conditions<br />

Suitable for any application:<br />

- SCALANCE W-788 for cabinet-free installation<br />

- SCALANCE W-786 for cabinet-free installation, also with<br />

integrated antennas<br />

- SCALANCE W-784 for installation in control cabinets or<br />

integrated into devices<br />

Wireless communication suitable for use in applications with<br />

high real-time and reliability requirements, such as PROFINET,<br />

PROFIsafe or video<br />

Standard-compliant thanks to IEEE <strong>80</strong>2.11 support, additional<br />

functional expansions especially for use with increased<br />

reliability<br />

Effective encryption mechanisms protect against<br />

unauthorized access, spying, tapping, and corruption<br />

The SINEMA E engineering tool, wizards and online help<br />

support planning, simulation, configuration and<br />

documentation; easy management with the web server and<br />

SNMP<br />

Fast commissioning of the Access Points thanks to the<br />

optional swap medium PRESET-PLUG and fast device<br />

replacement in the event of a fault thanks to the optional swap<br />

medium C-PLUG (Configuration Plug)<br />

Accessories such as antennas, connectors, cables incl.<br />

RCoax cables (leaky wave cables) that are tuned to one<br />

another for a reliable radio link<br />

■ Benefits<br />

Versatile possibilities for connection to the process, both wired<br />

and wireless<br />

Increased productivity, minimum engineering overhead,<br />

reduction in life-cycle costs<br />

Fast and accurate set-up as well as positioning<br />

Reliable operation with mature security concept<br />

Ergonomic and compact with low weight<br />

Rugged for industrial use<br />

Integral component of Totally Integrated Automation (TIA):<br />

Graphic library is available with preconfigured screen objects<br />

The data in the message buffer is stored retentively<br />

Can be used worldwide:<br />

- 32 online languages (incl. Asian and Cyrillic character sets)<br />

can be configured<br />

- Switchover between up to 16 online languages is possible<br />

directly on the Mobile Panel<br />

Reduction of service and commissioning costs due to:<br />

- Backup/restore via a process interface or optionally via a<br />

standard Multi Media Card / SD Card<br />

- Transfer of configuration with automatic transfer detection<br />

via all device interfaces<br />

- Long service life of the backlit display<br />

Easy engineering supported through comprehensive<br />

documentation on the SIMATIC HMI Manual Collection DVD<br />

2/47<br />

2


2<br />

Operator panels<br />

Mobile Panels<br />

Mobile Panels<br />

■ Application<br />

Regardless of the industry or application, if mobility is required<br />

for the on-site control and monitoring of machines and plants,<br />

SIMATIC mobile panels offer some crucial advantages: The<br />

machine operators or commissioning engineers are able to work<br />

exactly where they have the best view of the workpiece or<br />

process.<br />

Even for larger production facilities, complex or enclosed<br />

machines, long materials handling or production lines and<br />

conveyor systems, mobile operator panels allow fast and<br />

precise setting up and positioning during commissioning. They<br />

also ensure shorter downtimes during retooling, maintenance or<br />

repairs.<br />

■ Design<br />

Ergonomic and compact with various holder and grip<br />

positions (suitable for right-handed and left-handed persons)<br />

Pixel-graphics, high-luminance color display and touch<br />

screen (analog/resistive)<br />

Freely configurable and inscribable function keys (with LED)<br />

(not on Mobile Panel 277 10")<br />

The device is resistant to various oils, greases and general<br />

cleaning agents<br />

Extremely shock-resistant due to the double-walled<br />

construction and the round housing<br />

Dust-tight and splashwater protected enclosure with IP65<br />

all-round protection<br />

Slot for a standard Multi Media Card / SD Card for backing<br />

up/restoring the configuration or recipes<br />

Two three-stage acknowledgment buttons<br />

Optional device versions with<br />

- <strong>ST</strong>OP button or<br />

- <strong>ST</strong>OP button, handwheel, key-operated switch and<br />

illuminated pushbutton (not for Mobile Panel 277 10")<br />

- The <strong>ST</strong>OP button is specially secured with a protective collar.<br />

If the <strong>ST</strong>OP button is looped into the emergency-stop circuit,<br />

its function corresponds to that of an emergency stop button.<br />

Integrated serial, MPI/PROFIBUS (up to 12 Mbit/s) and/or<br />

PROFINET interface (up to 100 Mbit/s)<br />

or<br />

Connection to the PLC via the rugged and reliable terminal<br />

boxes with degree of protection IP65:<br />

- "Basic" terminal box: Enables the <strong>ST</strong>OP button to be<br />

integrated into the safety circuit<br />

- "Plus" terminal box: Enables the <strong>ST</strong>OP button to be<br />

integrated into the safety circuit without interruption when<br />

disconnecting the device. The emergency stop circuit<br />

remains closed regardless of whether a Mobile Panel is<br />

plugged in or not. If the Mobile Panel is disconnected during<br />

operation, the emergency stop circuit in the terminal box<br />

Plus is automatically closed which prevents triggering of the<br />

emergency stop circuit.<br />

Fast system availability after plugging into the terminal box<br />

- An optional rechargeable battery pack can be used to avoid<br />

restarting of the Mobile Panel (following brief disconnection<br />

from the terminal box).<br />

Detection of the connection point can be used to perform<br />

machine-specific HMI authorizations or actions depending on<br />

the selected connection point<br />

2/48<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Advanced safety concept<br />

The two acknowledgement buttons (acc. to EN 60204-1) with<br />

three switching steps each ensure the protection of personnel<br />

and machines in critical situations. They are integrated into the<br />

handle on the back.<br />

The <strong>ST</strong>OP button (acc. to EN 60204-1) is hard-wired and<br />

positively latches when pressed. It can be looped into the<br />

emergency-stop circuit of a plant in which case it takes on the<br />

functionality of an emergency stop button, but is distinct with its<br />

gray color. This ensures that it cannot be mistaken for the<br />

emergency stop equipment. This is especially important when<br />

the Mobile Panel is not connected to the machine. SIMATIC<br />

Mobile Panels offer the option of making safety functions<br />

available on a mobile basis at any point of a machine or plant.<br />

<strong>ST</strong>OP and acknowledgement buttons are implemented<br />

according to safety regulations with two circuits and comply with<br />

the requirements of Category 3 PLd according to<br />

EN ISO 13849-1:2008.<br />

Innovative connection concept<br />

The Mobile Panel is simply plugged into the terminal box<br />

wherever it is needed in the plant and is immediately ready for<br />

use. The terminal box can be installed anywhere, even outside<br />

the control cabinet. It ensures fault-free plugging and<br />

unplugging during normal operation and, therefore, allows the<br />

operator-control location to be easily and safely changed when<br />

several connection points are available in a plant or machine.<br />

The location of a Mobile Panel can be clearly identified by<br />

setting an ID number on the terminal box. This identifier permits<br />

the user to configure Mobile Panels in such a way that, for<br />

example, the user interface changes according to the<br />

connection point. The Mobile Panel establishes the connection<br />

to the controllers after being plugged into the terminal boxes and<br />

following a short start-up period. An optional rechargeable<br />

battery pack can be used to avoid restarting of the Mobile Panel<br />

(following brief disconnection from the terminal box).<br />

Configuration possibilities with emergency stop loop-in<br />

Device versions with <strong>ST</strong>OP button can be wired into the<br />

emergency stop circuit of a machine or plant by means of the<br />

terminal boxes. When the <strong>ST</strong>OP button on the Mobile Panel is<br />

pressed, the emergency stop function is activated. The<br />

<strong>ST</strong>OP button on the Mobile Panel supplements, but does not<br />

replace the emergency stop equipment installed on the machine<br />

according to EN 418. When the Mobile Panel is unplugged,<br />

"Plus" versions of the terminal box automatically close the<br />

emergency stop circuit, thereby ensuring safe and fault-free<br />

changeover (swapping).<br />

Connection at one point on the machine<br />

When the "Basic" terminal box version is used, unplugging the<br />

Mobile Panel interrupts the emergency stop circuit and,<br />

therefore, triggers the emergency stop function. This configuration<br />

is, therefore, best suited for applications in which the<br />

Mobile Panel is connected to a fixed point on the machine<br />

(example configuration: Mobile Panel 177).


■ Design (continued)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Variable connection at different points of a machine or plant<br />

If a Mobile Panel with a <strong>ST</strong>OP button is used in combination with<br />

a "Plus" terminal box, a configuration is possible in which the<br />

Mobile Panel can be used flexibly and is also looped into the<br />

emergency stop circuit. The emergency stop circuit remains<br />

closed regardless of whether a Mobile Panel is plugged into a<br />

terminal box or not. When the Mobile Panel is plugged in, the<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

SIMATIC Mobile Panel 277(F) IWLAN<br />

WLAN communication in accordance with IEEE <strong>80</strong>2.11 a (b/g)<br />

and support of PROFINET<br />

Two versions as a simple WLAN HMI device without safety<br />

function (Mobile Panel 277 IWLAN) as well as two versions as<br />

fail-safe PROFIsafe device with emergency stop button and<br />

acknowledgement button (Mobile Panel 277F IWLAN)<br />

Powerful batteries and flexible concept for changing permit<br />

battery replacement "on the fly" without interrupting operation<br />

thanks to integrated backup battery<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Mobile Panels<br />

<br />

<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Mobile Panels<br />

equipment is looped into the emergency stop circuit and when<br />

the <strong>ST</strong>OP button is pressed, the circuit will be interrupted and<br />

the emergency stop function triggered. If the Mobile Panel is<br />

unplugged during operation, the emergency stop circuit is<br />

automatically closed in the "Plus" terminal box version<br />

(example configuration: Mobile Panel 177).<br />

<br />

<br />

Limited effective range (Mobile Panel 277F IWLAN) and local<br />

identification of the device (Mobile Panel 277 (F) IWLAN) due<br />

to the use of transponder technology, comparable with<br />

connection point recognition on the cabled Mobile Panels or<br />

alternatively via RFID technology for systems with existing<br />

safety mechanisms, such as robot cell<br />

Optional versions with: Handwheel, key switch and<br />

illuminated pushbutton<br />

Fail-safe control elements of the SIMATIC Mobile<br />

Panel 277F IWLAN using PROFIsafe:<br />

- Two three-stage acknowledgement buttons<br />

- Emergency stop button<br />

<br />

2/49<br />

G_<strong>ST</strong><strong>80</strong>_XX_00348<br />

2


2<br />

Operator panels<br />

Mobile Panels<br />

Mobile Panels<br />

■ Design (continued)<br />

Mobile operator control and monitoring in the Industrial<br />

Wireless LAN<br />

The SIMATIC Mobile Panel 277(F) IWLAN enables the<br />

integration as a WLAN client in wireless LAN networks. This<br />

makes it possible to implement a full-fledged mobile HMI device,<br />

which can also perform tasks that are not possible with<br />

stationary or cabled devices.<br />

Reliable and rugged WLAN networks can be created using<br />

SCALANCE W IWLAN access points. The configuration and<br />

simulation software SINEMA E permits reliable WLAN planning<br />

ahead of time.<br />

The device is configured – just like the cabled Mobile Panels –<br />

with WinCC flexible. The compatibility and continuity permit easy<br />

and problem-free migration of existing projects to the wireless<br />

device.<br />

Transponders have been developed especially for the Mobile<br />

Panel 277(F) IWLAN and can be used for the local identification<br />

of the Mobile Panel in the plant. Comparable with the connection<br />

point recognition (Box-ID) for cabled Mobile Panels, these<br />

transponders can be used to configure location-dependent<br />

functions, e.g. the automatic switchover to a different display<br />

when a certain zone is accessed, or releasing/blocking of<br />

functions from the control zone.<br />

On the fail-safe Mobile Panel with enable button and emergency<br />

stop button (Mobile Panel 277F IWLAN), the transponders<br />

perform another task: The safety-related release of the enable<br />

button for hazardous operations. Alternatively, the Mobile Panel<br />

277F IWLAN (RFID Tag, MOBY D) for already delineated safety<br />

zones, such as robot cells, can be used. The monitoring of the<br />

protection zones is assumed by the alternative measures, not by<br />

the RFID Tag.<br />

Full safety functionality - even wireless!<br />

The SIMATIC Mobile Panel 277F IWLAN is integrated via<br />

PROFINET and PROFIsafe into the safety-oriented program<br />

(Distributed Safety) of a SIMATIC F-CPU. Incorporating and<br />

removing Mobile Panels is possible during runtime. Both of the<br />

safety-related functions "acknowledgement button" and<br />

"emergency stop button" comply with SIL 3 according to<br />

IEC 61508 or PLe/Cat. 4 according to EN ISO 13849-1 and are<br />

TÜV-certified. A detailed safety manual is delivered with the<br />

Mobile Panel 277F IWLAN, along with a CD containing the<br />

required F function blocks for integration in the F-program. The<br />

F-FBs are tested and certified - this enables a problem-free and<br />

simple integration of the Mobile Panel.<br />

The emergency stop button is immediately available WLANwide<br />

as soon as the Mobile Panel 277F IWLAN is booted up and<br />

the PROFISAFE connection is established with the F-CPU via<br />

IWLAN. To use the acknowledgment button locally, transponders<br />

or RFID tags must be installed in the intended control stations.<br />

This allows the Mobile Panel to register for safety-related<br />

operation.<br />

Configuration of the transponder and the effective range is also<br />

handled comfortably with WinCC flexible. After configuration<br />

and commissioning, the effective range in the system is<br />

approved to ensure the consistency of the planning and configuration.<br />

The effect that the emergency stop button and the<br />

acknowledgment button should have and which response to<br />

certain events (e.g. leaving the WLAN range) they should have<br />

is defined by configuring the F-FBs in the F-CPU – taking<br />

account of the safety-relevant properties of the machine. If the<br />

Mobile Panel is not used any longer or if the device should be<br />

removed, it is to be moved to a specified location.<br />

The Mobile Panel 277F IWLAN offers extensive diagnostic and<br />

status information (e.g. concerning the battery charge status,<br />

WLAN functionality, and quality of the effective range) and thus<br />

provides the user – if necessary, supported by the integrated<br />

vibration alarm – with full control of the device and system<br />

operation at all times.<br />

2/50<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

System components for wireless Mobile Panels<br />

Besides the five device versions, the following system components<br />

are offered (to be ordered individually):<br />

For charging the battery in the Mobile Panel (which can be<br />

replaced without tools), either<br />

the table-top power supply (incl. power cable for EU, US, UK,<br />

JP) is required (only suitable for operation under<br />

laboratory/office conditions) or<br />

the charging station, which enables the device to be safely put<br />

down and charged (incl. lock for securing the device in the<br />

charging station), as well as charging up to two additional<br />

batteries at the same time (IP65)<br />

For quick and interruption-free battery replacement during<br />

operation<br />

Additional battery with LED indicator for indicating the charge<br />

status<br />

To create zones (optional for all versions) and mandatory for<br />

using the enable button in the effective ranges with Mobile Panel<br />

277F IWLAN:<br />

Transponder (incl. batteries for self-sufficient operation over<br />

several years, no cabling is required on the transponder).<br />

For the use of the Mobile Panel 277F IWLAN (RFID Tag) in<br />

robot cells, the MOBY D RFID card system:<br />

MOBY D MDS D 100 (6GT2600-0AD10) or MDS D 124<br />

(6GT2600-0AC00).


■ Overview<br />

SIMATIC Moble Panel 177 PN with terminal box<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Mobile Panels — 170 series<br />

SIMATIC Mobile Panel 177<br />

■ Function<br />

Input/output fields<br />

for displaying and changing process values<br />

Function keys<br />

are used for directly triggering functions and actions. Up to<br />

16 functions can be configured simultaneously on function<br />

keys. The function keys can also be used as PROFIBUS DP<br />

input I/O or directly as PROFINET IO.<br />

The function keys can also be reconfigured as system keys.<br />

A function that is used frequently such as "Acknowledge<br />

message" can be allocated to a function key this way.<br />

Additional operator controls<br />

such as handwheel, keyswitch and illuminated pushbutton<br />

can be connected to a variable or as a direct control over<br />

PROFIBUS DP input I/O (DP direct keys) or PROFINET IO<br />

(direct keys).<br />

Buttons<br />

are used for directly triggering functions and actions. Up to<br />

16 functions can be configured simultaneously on buttons.<br />

Graphics<br />

can be used as symbols instead of text to "label" function keys<br />

or buttons. They can also be used as full-screen background<br />

images.<br />

In the configuration software, a comprehensive library is<br />

available containing graphics and a wide variety of objects. All<br />

editors with an OLE interface can be used as graphic editors<br />

(such as PaintShop, Designer or CorelDraw).<br />

Vector graphics;<br />

simple geometric basic forms (e.g. lines, circles and<br />

rectangles) can be created direct in the configuring software<br />

Text fields<br />

for labeling function keys, process images and process<br />

values in any character size<br />

Curve displays and bars<br />

are used for the display of dynamic values in graphic-based<br />

format<br />

Display selection from the controller<br />

permits operator prompting from the controller<br />

Language selection;<br />

5 online languages, 32 configuration languages incl. Asian<br />

and Cyrillic character sets<br />

Language-dependent texts and graphics<br />

User administration (security)<br />

- User-oriented access protection according to requirements<br />

of specific sectors<br />

- Authentication with user name and password<br />

- User-group-specific rights<br />

Signaling system<br />

- Discrete alarms and analog alarms (limit value messages)<br />

as well as the ALARM_S message frame procedure for<br />

SIMATIC S7 and SIMOTION<br />

- Freely definable message classes (e.g. status/fault<br />

messages) for definition of acknowledgment response and<br />

display of message events<br />

Message buffer<br />

- Non-volatile, maintenance-free and battery-free message<br />

buffer. The messages are retained even when the Mobile<br />

Panel is disconnected.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/51<br />

2


2<br />

Operator panels<br />

Mobile Panels — 170 series<br />

SIMATIC Mobile Panel 177<br />

■ Function (continued)<br />

■ Integration<br />

Recipe management<br />

In the case of the Mobile Panel 177 DP, communication with the<br />

- With additional data storage (on optional Multimedia<br />

PLC can be implemented via PROFIBUS DP at up to 12 Mbit/s,<br />

Card/SD Card)<br />

via MPI or via the serial interface. The necessary interfaces are<br />

- Online/offline processing on the panel<br />

already onboard. A variety of drivers – even for PLCs from other<br />

- Storage of recipe data in standard Windows format (CSV) suppliers – are supplied as standard.<br />

- External processing using standard tools such as Excel and<br />

Access is possible<br />

In the case of the Mobile Panel 177 PN, communication with the<br />

PLC can be implemented via PROFINET at up to 100 Mbit/s. The<br />

Help texts<br />

necessary interfaces are already onboard. These are supplied<br />

for process images, messages and variables<br />

with the device.<br />

Arithmetic functions<br />

Using the terminal boxes the Mobile Panel 177 can be<br />

Limit value monitoring<br />

connected to (see "System interfaces"):<br />

for reliable process control of inputs and outputs<br />

SIMATIC S7-200/-300/-400<br />

Indicator light<br />

for machine and plant status indication<br />

SIMATIC WinAC Software/Slot PLC<br />

Scheduler<br />

SIMOTION<br />

for cyclic function execution<br />

SIMATIC S5<br />

Dynamic positioning of objects and dynamic showing/hiding SIMATIC 505 (not on Mobile Panel 177 PN)<br />

of objects<br />

Third-party controllers<br />

Permanent window and template concept<br />

- Allen Bradley<br />

- Creation of screen templates:<br />

- Mitsubishi (not on Mobile Panel 177 PN)<br />

Simple maintenance and configuration thanks to:<br />

- Modicon Modbus<br />

- Backup/restore of the project, operating system, recipe data - GE-Fanuc (not on Mobile Panel 177 PN)<br />

records and firmware on the optional standard Multimedia - LG GLOFA GM (not on Mobile Panel 177 PN)<br />

Card/SD card<br />

- OMRON (not on Mobile Panel 177 PN)<br />

- Backup and restoration (Backup/Restore) of configuration, - Telemechanique Uni-Telway (not on Mobile Panel 177 PN)<br />

operating system, recipe data sets and firmware on a <strong>PC</strong> SINUMERIK<br />

using ProSave<br />

(optionally with "SINUMERIK HMI copy license WinCC flexible<br />

- Project transfer/return via MPI/PROFIBUS DP/serial or<br />

CE"; "SINUMERIK HMI engineering package WinCC flexible"<br />

PROFINET<br />

is additionally required for configuring;<br />

- Automatic transfer identification<br />

For further details, see <strong>Catalog</strong> NC 60)<br />

- Individual contrast settings<br />

- Project simulation directly on the configuration computer<br />

Using the DP junctions boxes the Mobile Panel 177 PN can be<br />

connected to:<br />

WinCC flexible options<br />

- Sm@rtService for remote operator control and monitoring of<br />

SIMATIC S7-200/-300/-400<br />

SIMATIC HMI systems based on TCP/IP networks<br />

WinAC Software<br />

- Sm@rtAccess for communication between HMI systems SIMOTION<br />

based on TCP/IP networks. Remote access to recipe data<br />

sets, passwords and information specific to the HMI system,<br />

and much more.<br />

Note:<br />

Migration<br />

The unwanted operation of a Mobile Panel 177 DP (PROFIBUS)<br />

- Any existing Mobile Panel 170 terminal boxes can be used on a PN (PROFINET) terminal box and vice versa is not possible<br />

in conjunction with the Mobile Panel 177 because they are and is mechanically blocked. Further information can be found<br />

fully compatible. The function of connection-point detection under "System interfaces".<br />

can only be used in conjunction with a Mobile Panel 177 with<br />

a DP or PN terminal box.<br />

- Projects created with WinCC flexible for the Mobile Panel can<br />

simply continue to be used in WinCC V11<br />

Configuration<br />

Configuration is carried out with the SIMATIC WinCC flexible,<br />

2005 or later, Compact, Standard or Advanced engineering<br />

software (see SIMATIC WinCC flexible HMI<br />

software/engineering software) or WinCC V11.<br />

SIMATIC WinCC is the logical further development of the fieldproven<br />

WinCC flexible family. Projects generated using WinCC<br />

flexible can be easily migrated to WinCC. If WinCC flexible is<br />

started directly from SIMATIC Manager, the data in <strong>ST</strong>EP 7 can<br />

be accessed directly while configuring the panel. Duplicated<br />

data input and data management is, therefore, avoided.<br />

2/52<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Technical specifications<br />

SIMATIC Mobile Panel 177 PN<br />

(PROFINET)<br />

Operator panels<br />

Mobile Panels — 170 series<br />

SIMATIC Mobile Panel 177<br />

6AV6 645-0AA01-0AX0 6AV6 645-0AB01-0AX0 6AV6 645-0AC01-0AX0<br />

with integrated acknowledgment<br />

button<br />

with integrated acknowledgment<br />

button and <strong>ST</strong>OP<br />

button<br />

with integrated acknowledgment<br />

button, <strong>ST</strong>OP button,<br />

handwheel, keyswitch and<br />

illuminated pushbutton<br />

Display<br />

Size 5.7" (121 mm x 92 mm) 5.7" (121 mm x 92 mm) 5.7" (121 mm x 92 mm)<br />

Display type<br />

Resolution (pixels)<br />

<strong>ST</strong>N, 256 colors <strong>ST</strong>N, 256 colors <strong>ST</strong>N, 256 colors<br />

Resolution (WxH in pixel)<br />

Backlighting<br />

320 x 240 320 x 240 320 x 240<br />

MTBF backlighting (at 25 °C)<br />

Control elements<br />

about 50,000 hours about 50,000 hours about 50,000 hours<br />

Operating options Keys and Touch Keys and Touch Keys and Touch<br />

Function keys, programmable<br />

Keyboard<br />

14 function keys, 8 with LEDs 14 function keys, 8 with LEDs 14 function keys, 8 with LEDs<br />

System keys 0 0 0<br />

Numeric/alphabetical input<br />

Touch operation<br />

Yes / Yes Yes / Yes Yes / Yes<br />

Touch screen analog, resistive analog, resistive analog, resistive<br />

Special operator controls<br />

<strong>ST</strong>OP pushbutton No 2-channel, enforced latching<br />

(can be looped into the emergency<br />

stop circuit)<br />

2-channel, enforced latching<br />

(can be looped into the emergency<br />

stop circuit)<br />

Acknowledgement button 2-channel, number of positions: 3 2-channel, number of positions: 3 2-channel, number of positions: 3<br />

Key-operated switch No No Yes, 3 switch settings<br />

Illuminated pushbutton No No Yes<br />

Handwheel<br />

Expansions for operator control of<br />

the process<br />

No No Yes<br />

DP direct LEDs (LEDs as S7<br />

output I/O)<br />

F1...F8 F1...F8 F1...F8<br />

DP direct keys (screen buttons and<br />

keys as S7 input I/O )<br />

Supply voltage<br />

Input voltage<br />

F1...F14 F1...F14 F1...F14<br />

Supply voltage<br />

Backup battery<br />

via connection box via connection box via connection box<br />

Battery operation<br />

Processor<br />

maximum buffer time 10 min maximum buffer time 10 min maximum buffer time 10 min<br />

Processor<br />

Memory<br />

RISC 32-bit, 200 MHz RISC 32-bit, 200 MHz RISC 32-bit, 200 MHz<br />

Type Flash / RAM Flash / RAM Flash / RAM<br />

Usable memory for user data 2048 KB of usable memory for user<br />

data / no user memory for options<br />

2048 KB of usable memory for user<br />

data / no user memory for options<br />

Type of output<br />

LED colors Green Green Green<br />

Acoustics No No No<br />

Interfaces<br />

Interfaces 1 x RS422, 1 x RS485<br />

(max. 12 Mbit/s)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

1 x RS422, 1 x RS485<br />

(max. 12 Mbit/s)<br />

2048 KB of usable memory for user<br />

data / no user memory for options<br />

1 x RS422, 1 x RS485<br />

(max. 12 Mbit/s)<br />

USB port No No No<br />

<strong>PC</strong> card slot No No No<br />

CF card slot No No No<br />

Multimedia card<br />

Industrial Ethernet<br />

combined combined combined<br />

Industrial Ethernet interface No No No<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/53<br />

2


2<br />

Operator panels<br />

Mobile Panels — 170 series<br />

SIMATIC Mobile Panel 177<br />

■ Technical specifications (continued)<br />

SIMATIC Mobile Panel 177 PN<br />

(PROFINET)<br />

Ambient conditions<br />

Operating temperature<br />

Operation<br />

Storage/transport temperature<br />

0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C<br />

Transport, storage<br />

Relative humidity<br />

-20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C<br />

max. relative humidity <strong>80</strong> % <strong>80</strong> % <strong>80</strong> %<br />

Drop height<br />

Degree and class of protection<br />

1.5 m 1.5 m 1.5 m<br />

IP65 housing<br />

Standards, approvals, certificates<br />

Yes Yes Yes<br />

Certifications CE, cULus, C-TICK, SIBE CE, cULus, C-TICK, SIBE CE, cULus, C-TICK, SIBE<br />

Performance level acc. to<br />

EN ISO 13849-1<br />

d d d<br />

Safety category according to<br />

EN954-1<br />

2/54<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Safety category according to<br />

EN954-1 (enabling button,<br />

<strong>ST</strong>OP button if present) 3<br />

Safety category according to<br />

EN954-1 (enabling button,<br />

<strong>ST</strong>OP button if present) 3<br />

Safety category according to<br />

EN954-1 (enabling button,<br />

<strong>ST</strong>OP button if present) 3<br />

Operating systems<br />

Operating system<br />

Configuration<br />

Configuration software<br />

Windows CE Windows CE Windows CE<br />

Configuration tool<br />

Functionality under WinCC<br />

flexible/WinCC (TIA Portal)<br />

see "Configuration overview" from page 2/3<br />

Applications/options see chapter 4: HMI software/SIMATIC WinCC flexible options and SIMATIC WinCC<br />

(TIA portal) options<br />

Number of Visual Basic Scripts Not possible Not possible Not possible<br />

Task planner Yes Yes Yes<br />

Help system Yes Yes Yes<br />

Status/control<br />

With alarm logging system<br />

(incl. buffer and acknowledgment)<br />

with SIMATIC S7 with SIMATIC S7 with SIMATIC S7<br />

Number of messages 2000 2000 2000<br />

Bit messages Yes Yes Yes<br />

Analog messages Yes Yes Yes<br />

Message buffer Ring buffer (n x 256 entries),<br />

retentive, maintenance-free<br />

Ring buffer (n x 256 entries),<br />

retentive, maintenance-free<br />

Recipes<br />

Recipes 100 100 100<br />

Data records per recipe 200 200 200<br />

Entries per data record 200 200 200<br />

Recipe memory 32 KB integrated Flash,<br />

expandable<br />

32 KB integrated Flash,<br />

expandable<br />

Ring buffer (n x 256 entries),<br />

retentive, maintenance-free<br />

32 KB integrated Flash,<br />

expandable<br />

Number of process images<br />

Process images 500 500 500<br />

Variables 1024 1024 1024<br />

Limit values Yes Yes Yes<br />

Multiplexing<br />

Image elements<br />

Yes Yes Yes<br />

Text objects 2,500 text elements 2,500 text elements 2,500 text elements<br />

Graphic object Bit maps, vector graphics Bit maps, vector graphics Bit maps, vector graphics<br />

dynamic objects Diagrams, bar graphs, sliders,<br />

invisible buttons<br />

6AV6 645-0AA01-0AX0 6AV6 645-0AB01-0AX0 6AV6 645-0AC01-0AX0<br />

with integrated acknowledgment<br />

button<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

with integrated acknowledgment<br />

button and <strong>ST</strong>OP<br />

button<br />

Diagrams, bar graphs, sliders,<br />

invisible buttons<br />

with integrated acknowledgment<br />

button, <strong>ST</strong>OP button,<br />

handwheel, keyswitch and<br />

illuminated pushbutton<br />

Diagrams, bar graphs, sliders,<br />

invisible buttons


■ Technical specifications (continued)<br />

SIMATIC Mobile Panel 177 PN<br />

(PROFINET)<br />

Operator panels<br />

Mobile Panels — 170 series<br />

SIMATIC Mobile Panel 177<br />

Lists<br />

Text lists 300 300 300<br />

Graphics list 100 100 100<br />

Libraries<br />

Security<br />

Yes Yes Yes<br />

Number of user groups 50 50 50<br />

Passwords exportable Yes Yes Yes<br />

Number of user rights<br />

Data carrier support<br />

32 32 32<br />

<strong>PC</strong> card No No No<br />

CF card No No No<br />

Multimedia Card<br />

Recording<br />

Yes Yes Yes<br />

Recording/Printing - - -<br />

Printer driver<br />

Fonts<br />

- - -<br />

Keyboard fonts US American (English) US American (English) US American (English)<br />

Languages<br />

Configuration languages D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified", DK, FIN, GR, J,<br />

KP / ROK, NL, N, PL, P, RUS, S,<br />

CZ / SK, TR, H<br />

Character sets Tahoma, WinCC flexible Standard,<br />

symbol languages, all freely<br />

scalable<br />

Transfer (upload/download)<br />

Transfer of configuration MPI/PROFIBUS DP, serial,<br />

automatic transfer recognition<br />

6AV6 645-0AA01-0AX0 6AV6 645-0AB01-0AX0 6AV6 645-0AC01-0AX0<br />

with integrated acknowledgment<br />

button<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

with integrated acknowledgment<br />

button and <strong>ST</strong>OP<br />

button<br />

D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified", DK, FIN, GR, J,<br />

KP / ROK, NL, N, PL, P, RUS, S,<br />

CZ / SK, TR, H<br />

Tahoma, WinCC flexible Standard,<br />

symbol languages, all freely<br />

scalable<br />

MPI/PROFIBUS DP, serial,<br />

automatic transfer recognition<br />

with integrated acknowledgment<br />

button, <strong>ST</strong>OP button,<br />

handwheel, keyswitch and<br />

illuminated pushbutton<br />

D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified", DK, FIN, GR, J,<br />

KP / ROK, NL, N, PL, P, RUS, S,<br />

CZ / SK, TR, H<br />

Tahoma, WinCC flexible Standard,<br />

symbol languages, all freely<br />

scalable<br />

MPI/PROFIBUS DP, serial,<br />

automatic transfer recognition<br />

Process coupling<br />

Connection to controller<br />

Expandability/openness<br />

see "System interfaces" from page 2/178<br />

Open Platform Program<br />

Mechanics/material<br />

Yes Yes Yes<br />

Type of housing (front)<br />

Dimensions and weight<br />

Dimensions<br />

Plastic Plastic Plastic<br />

Housing diameter/depth (mm)<br />

Weight<br />

Dia 245 mm / D 58 mm Dia 245 mm / D 58 mm Dia 245 mm / D 58 mm<br />

Weight 1.3 kg 1.3 kg 1.3 kg<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/55<br />

2


2<br />

Operator panels<br />

Mobile Panels — 170 series<br />

SIMATIC Mobile Panel 177<br />

■ Technical specifications (continued)<br />

SIMATIC Mobile Panel 177 DP<br />

(MPI/PROFIBUS)<br />

2/56<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6AV6 645-0BA01-0AX0 6AV6 645-0BB01-0AX0 6AV6 645-0BC01-0AX0<br />

with integrated acknowledgment<br />

button<br />

with integrated acknowledgment<br />

button and <strong>ST</strong>OP<br />

button<br />

with integrated acknowledgment<br />

button, <strong>ST</strong>OP button,<br />

handwheel, keyswitch and<br />

illuminated pushbutton<br />

Display<br />

Size 5.7" (121 mm x 92 mm) 5.7" (121 mm x 92 mm) 5.7" (121 mm x 92 mm)<br />

Display type<br />

Resolution (pixels)<br />

<strong>ST</strong>N, 256 colors <strong>ST</strong>N, 256 colors <strong>ST</strong>N, 256 colors<br />

Resolution (WxH in pixel)<br />

Backlighting<br />

320 x 240 320 x 240 320 x 240<br />

MTBF backlighting (at 25 °C)<br />

Control elements<br />

about 50,000 hours about 50,000 hours about 50,000 hours<br />

Operating options Keys and Touch Keys and Touch Keys and Touch<br />

Function keys, programmable<br />

Keyboard<br />

14 function keys, 8 with LEDs 14 function keys, 8 with LEDs 14 function keys, 8 with LEDs<br />

System keys 0 0 0<br />

Numeric/alphabetical input<br />

Touch operation<br />

Yes / Yes Yes / Yes Yes / Yes<br />

Touch screen analog, resistive analog, resistive analog, resistive<br />

Special operator controls<br />

<strong>ST</strong>OP pushbutton No 2-channel, enforced latching<br />

(can be looped into the emergency<br />

stop circuit)<br />

2-channel, enforced latching<br />

(can be looped into the emergency<br />

stop circuit)<br />

Acknowledgement button 2-channel, number of positions: 3 2-channel, number of positions: 3 2-channel, number of positions: 3<br />

Key-operated switch No No Yes, 3 switch settings<br />

Illuminated pushbutton No No Yes<br />

Handwheel<br />

Expansions for operator control of<br />

the process<br />

No No Yes<br />

DP direct LEDs (LEDs as S7<br />

output I/O)<br />

F1...F8 F1...F8 F1...F8<br />

DP direct keys (screen buttons and<br />

keys as S7 input I/O )<br />

Supply voltage<br />

Input voltage<br />

F1...F14 F1...F14 F1...F14<br />

Supply voltage<br />

Backup battery<br />

via connection box via connection box via connection box<br />

Battery operation<br />

Processor<br />

maximum buffer time 10 min maximum buffer time 10 min maximum buffer time 10 min<br />

Processor<br />

Memory<br />

RISC 32-bit, 200 MHz RISC 32-bit, 200 MHz RISC 32-bit, 200 MHz<br />

Type Flash / RAM Flash / RAM Flash / RAM<br />

Usable memory for user data 2048 KB of usable memory for user<br />

data / no user memory for options<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

2048 KB of usable memory for user<br />

data / no user memory for options<br />

2048 KB of usable memory for user<br />

data / no user memory for options<br />

Type of output<br />

LED colors Green Green Green<br />

Acoustics<br />

Interfaces<br />

No No No<br />

Interfaces 1 x RS485, 1 x Ethernet (RJ45) 1 x RS485, 1 x Ethernet (RJ45) 1 x RS485, 1 x Ethernet (RJ45)<br />

USB port No No No<br />

<strong>PC</strong> card slot No No No<br />

CF card slot No No No<br />

Multimedia card<br />

Industrial Ethernet<br />

combined combined combined<br />

Industrial Ethernet interface 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45)


■ Technical specifications (continued)<br />

SIMATIC Mobile Panel 177 DP<br />

(MPI/PROFIBUS)<br />

Operator panels<br />

Mobile Panels — 170 series<br />

SIMATIC Mobile Panel 177<br />

Ambient conditions<br />

Operating temperature<br />

Operation<br />

Storage/transport temperature<br />

0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C<br />

Transport, storage<br />

Relative humidity<br />

-20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C<br />

max. relative humidity <strong>80</strong> % <strong>80</strong> % <strong>80</strong> %<br />

Drop height<br />

Degree and class of protection<br />

1.5 m 1.5 m 1.5 m<br />

IP65 housing<br />

Standards, approvals, certificates<br />

Yes Yes Yes<br />

Certifications CE, cULus, C-TICK, SIBE CE, cULus, C-TICK, SIBE CE, cULus, C-TICK, SIBE<br />

Performance level acc. to<br />

EN ISO 13849-1<br />

d d d<br />

Safety category according to<br />

EN954-1<br />

Safety category according to<br />

EN954-1 (enabling button, <strong>ST</strong>OP<br />

button if present) 3<br />

Safety category according to<br />

EN954-1 (enabling button, <strong>ST</strong>OP<br />

button if present) 3<br />

Safety category according to<br />

EN954-1 (enabling button, <strong>ST</strong>OP<br />

button if present) 3<br />

Operating systems<br />

Operating system<br />

Configuration<br />

Configuration software<br />

Windows CE Windows CE Windows CE<br />

Configuration tool<br />

Functionality under WinCC<br />

flexible/WinCC (TIA Portal)<br />

see chapter 4: HMI software/SIMATIC WinCC flexible options and SIMATIC WinCC<br />

(TIA portal) options<br />

Applications/options Sm@rtService, Sm@rtAccess Sm@rtService, Sm@rtAccess Sm@rtService, Sm@rtAccess<br />

Number of Visual Basic Scripts Not possible Not possible Not possible<br />

Task planner Yes Yes Yes<br />

Help system Yes Yes Yes<br />

Status/control<br />

With alarm logging system<br />

(incl. buffer and acknowledgment)<br />

with SIMATIC S7 with SIMATIC S7 with SIMATIC S7<br />

Number of messages 2000 2000 2000<br />

Bit messages Yes Yes Yes<br />

Analog messages Yes Yes Yes<br />

Message buffer Ring buffer (n x 256 entries),<br />

retentive, maintenance-free<br />

Ring buffer (n x 256 entries),<br />

retentive, maintenance-free<br />

Recipes<br />

Recipes 100 100 100<br />

Data records per recipe 200 200 200<br />

Entries per data record 200 200 200<br />

Recipe memory 32 KB integrated Flash,<br />

expandable<br />

32 KB integrated Flash,<br />

expandable<br />

Ring buffer (n x 256 entries),<br />

retentive, maintenance-free<br />

32 KB integrated Flash,<br />

expandable<br />

Number of process images<br />

Process images 500 500 500<br />

Variables 1024 1024 1024<br />

Limit values Yes Yes Yes<br />

Multiplexing<br />

Image elements<br />

Yes Yes Yes<br />

Text objects 2,500 text elements 2,500 text elements 2,500 text elements<br />

Graphics object Bit maps, vector graphics Bit maps, vector graphics Bit maps, vector graphics<br />

dynamic objects Diagrams, bar graphs, sliders,<br />

invisible buttons<br />

6AV6 645-0BA01-0AX0 6AV6 645-0BB01-0AX0 6AV6 645-0BC01-0AX0<br />

with integrated acknowledgment<br />

button<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

with integrated acknowledgment<br />

button and <strong>ST</strong>OP<br />

button<br />

Diagrams, bar graphs, sliders,<br />

invisible buttons<br />

Lists<br />

Text lists 300 300 300<br />

Graphic list 100 100 100<br />

Libraries Yes Yes Yes<br />

with integrated acknowledgment<br />

button, <strong>ST</strong>OP button,<br />

handwheel, keyswitch and<br />

illuminated pushbutton<br />

Diagrams, bar graphs, sliders,<br />

invisible buttons<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/57<br />

2


2<br />

Operator panels<br />

Mobile Panels — 170 series<br />

SIMATIC Mobile Panel 177<br />

■ Technical specifications (continued)<br />

SIMATIC Mobile Panel 177 DP<br />

(MPI/PROFIBUS)<br />

Security<br />

Number of user groups 50 50 50<br />

Passwords exportable Yes Yes Yes<br />

Number of user rights<br />

Data carrier support<br />

32 32 32<br />

<strong>PC</strong> card No No No<br />

CF card No No No<br />

Multimedia Card<br />

Recording<br />

Yes Yes Yes<br />

Recording/Printing - - -<br />

Printer driver<br />

Fonts<br />

- - -<br />

Keyboard fonts US American (English) US American (English) US American (English)<br />

Languages<br />

Configuration languages D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified", DK, FIN, GR, J,<br />

KP / ROK, NL, N, PL, P, RUS, S,<br />

CZ / SK, TR, H<br />

Character sets Tahoma, WinCC flexible Standard,<br />

symbol languages, all freely<br />

scalable<br />

Transfer (upload/download)<br />

Transfer of configuration serial, Ethernet, automatic transfer<br />

recognition<br />

Process coupling<br />

Connection to controller S7-200, S7- 300/400, Win AC,<br />

<strong>PC</strong> (TCP/IP), SIMOTION, Modicon<br />

(Modbus), see the chapter "System<br />

interfaces"<br />

2/58<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6AV6 645-0BA01-0AX0 6AV6 645-0BB01-0AX0 6AV6 645-0BC01-0AX0<br />

with integrated acknowledgment<br />

button<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

with integrated acknowledgment<br />

button and <strong>ST</strong>OP<br />

button<br />

D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified", DK, FIN, GR, J,<br />

KP / ROK, NL, N, PL, P, RUS, S,<br />

CZ / SK, TR, H<br />

Tahoma, WinCC flexible Standard,<br />

symbol languages, all freely<br />

scalable<br />

serial, Ethernet, automatic transfer<br />

recognition<br />

S7-200, S7- 300/400, Win AC,<br />

<strong>PC</strong> (TCP/IP), SIMOTION, Modicon<br />

(Modbus), see the chapter "System<br />

interfaces"<br />

with integrated acknowledgment<br />

button, <strong>ST</strong>OP button,<br />

handwheel, keyswitch and<br />

illuminated pushbutton<br />

D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified", DK, FIN, GR, J,<br />

KP / ROK, NL, N, PL, P, RUS, S,<br />

CZ / SK, TR, H<br />

Tahoma, WinCC flexible Standard,<br />

symbol languages, all freely<br />

scalable<br />

serial, Ethernet, automatic transfer<br />

recognition<br />

S7-200, S7- 300/400, Win AC,<br />

<strong>PC</strong> (TCP/IP), SIMOTION, Modicon<br />

(Modbus), see the chapter "System<br />

interfaces"<br />

Expandability/openness<br />

Open Platform Program<br />

I/O<br />

Yes Yes Yes<br />

I/O devices<br />

Mechanics/material<br />

Printer Printer Printer<br />

Type of housing (front)<br />

Dimensions and weight<br />

Dimensions<br />

Plastic Plastic Plastic<br />

Housing diameter/depth (mm)<br />

Weight<br />

Dia 245 mm / D 58 mm Dia 245 mm / D 58 mm Dia 245 mm / D 58 mm<br />

Weight 1.3 kg 1.3 kg 1.3 kg


Operator panels<br />

Mobile Panels — 170 series<br />

■ Ordering data Order No. Order No.<br />

SIMATIC Mobile Panel 177 DP<br />

(MPI/PROFIBUS) 1)<br />

With integrated acknowledgement<br />

button<br />

E 6AV6 645-0AA01-0AX0<br />

With integrated acknowledgement<br />

button and <strong>ST</strong>OP<br />

pushbutton<br />

E 6AV6 645-0AB01-0AX0<br />

With integrated acknowledgement<br />

button, <strong>ST</strong>OP button,<br />

handwheel, key-operated switch<br />

and illuminated pushbutton<br />

E 6AV6 645-0AC01-0AX0<br />

SIMATIC Mobile Panel 177 PN<br />

(PROFINET) 1)<br />

With integrated acknowledgement<br />

button<br />

E 6AV6 645-0BA01-0AX0<br />

With integrated acknowledgement<br />

button and <strong>ST</strong>OP<br />

pushbutton<br />

E 6AV6 645-0BB01-0AX0<br />

With integrated acknowledgement<br />

button, <strong>ST</strong>OP button,<br />

handwheel, key-operated switch<br />

and illuminated pushbutton<br />

E 6AV6 645-0BC01-0AX0<br />

Configuration<br />

with SIMATIC WinCC flexible<br />

Documentation<br />

(to be ordered separately)<br />

Operating Instructions for<br />

Mobile Panel 177<br />

see chapter 4<br />

German 6AV6 691-1DK01-0AA0<br />

English 6AV6 691-1DK01-0AB0<br />

French 6AV6 691-1DK01-0AC0<br />

Italian 6AV6 691-1DK01-0AD0<br />

Spanish<br />

User Manual WinCC flexible<br />

Compact/Standard/Advanced<br />

6AV6 691-1DK01-0AE0<br />

German 6AV6 691-1AB01-3AA0<br />

English 6AV6 691-1AB01-3AB0<br />

French 6AV6 691-1AB01-3AC0<br />

Italian 6AV6 691-1AB01-3AD0<br />

Spanish<br />

WinCC flexible Communication<br />

User Manual<br />

6AV6 691-1AB01-3AE0<br />

German 6AV6 691-1CA01-3AA0<br />

English 6AV6 691-1CA01-3AB0<br />

French 6AV6 691-1CA01-3AC0<br />

Italian 6AV6 691-1CA01-3AD0<br />

Spanish 6AV6 691-1CA01-3AE0<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC Mobile Panel 177<br />

SIMATIC HMI Manual Collection B<br />

Electronic documentation,<br />

on DVD<br />

5 languages (English, French,<br />

German, Italian and Spanish);<br />

contains: all currently available<br />

user manuals, manuals and<br />

communication manuals for<br />

SIMATIC HMI<br />

System components for Mobile<br />

Panels<br />

DP terminal box for Mobile<br />

Panels (MPI/PROFIBUS)<br />

6AV6 691-1SA01-0AX0<br />

Basic 6AV6 671-5AE00-0AX0<br />

Plus<br />

PN terminal box for Mobile<br />

Panel (PROFINET)<br />

A 6AV6 671-5AE10-0AX0<br />

Basic A 6AV6 671-5AE01-0AX0<br />

Plus<br />

DP connecting cable<br />

(MPI/PROFIBUS)<br />

Standard cables<br />

A 6AV6 671-5AE11-0AX0<br />

2 m 6XV1 440-4AH20<br />

5 m 6XV1 440-4AH50<br />

10 m 6XV1 440-4AN10<br />

15 m 6XV1 440-4AN15<br />

25 m<br />

Intermediate lengths<br />

6XV1 440-4AN25<br />

2)<br />

8 m 6XV1 440-4AH<strong>80</strong><br />

20 m<br />

PN connecting cable<br />

(PROFINET)<br />

Standard cables<br />

6XV1 440-4AN20<br />

2 m 6XV1 440-4BH20<br />

5 m 6XV1 440-4BH50<br />

8 m 6XV1 440-4BH<strong>80</strong><br />

10 m 6XV1 440-4BN10<br />

15 m 6XV1 440-4BN15<br />

20 m 6XV1 440-4BN20<br />

25 m 6XV1 440-4BN25<br />

Accessories see HMI accessories<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

1) The system components (connecting cables and terminal boxes)<br />

must be ordered separately.<br />

2) Delivery time approximately 6 weeks<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/59<br />

2


2<br />

Operator panels<br />

Mobile Panels — 170 series<br />

SIMATIC Mobile Panel 177<br />

■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical<br />

specifications.<br />

Mobile Panel 177 – front view and side view<br />

2/60<br />

121.7<br />

92.3<br />

245<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

7.<strong>80</strong><br />

123.9<br />

61.3<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00046<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-mobile-panels<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.


© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Overview ■ Function<br />

Operator panels<br />

Mobile Panels - 270 series<br />

SIMATIC Mobile Panel 277<br />

Input/output fields<br />

for displaying and changing of process values<br />

Function keys<br />

are used for directly triggering functions and actions. Up to<br />

16 functions can be configured simultaneously on function<br />

keys. The function keys can also be used as PROFIBUS DP<br />

input I/O or directly as PROFINET IO. The function keys can<br />

also be reconfigured as system keys. A frequently used<br />

function such as "Acknowledge alarm" can thus be assigned<br />

to a function key.<br />

No function keys are available on the Mobile Panel 277 10".<br />

Additional command components<br />

such as handwheel, keyswitch and illuminated pushbutton<br />

can be connected to a variable or as a direct control over<br />

PROFIBUS DP input I/O (DP direct keys) or PROFINET IO<br />

(direct keys).<br />

No additional operator controls are available on the<br />

Mobile Panel 277 10".<br />

Buttons<br />

are used for direct triggering of functions and actions. Up to<br />

16 functions can be configured simultaneously on buttons.<br />

Graphics<br />

can be used as symbols instead of text for "labeling" function<br />

keys or buttons. They can also be used as full-screen<br />

background images.<br />

In the configuration software, a comprehensive library is<br />

available containing graphics and a wide variety of objects. All<br />

editors with an OLE interface can be used as graphic editors<br />

(such as PaintShop, Designer or CorelDraw).<br />

Vector graphics<br />

simple geometric basic forms (e.g. lines, circles and<br />

rectangles) can be created directly in the configuration<br />

software.<br />

Text fields<br />

for labeling function keys, process displays, and process<br />

values in any font size.<br />

Trend views and bars<br />

are used for the graphic display of dynamic values.<br />

Display selection from the controller<br />

permits operator prompting from the controller.<br />

Presentation of HTML documents with MS Pocket Internet<br />

Explorer.<br />

Visual Basic Script, flexibility thanks to the implementation of<br />

new functions including linking to variables (comparison<br />

operations, loops, etc.).<br />

Language switching<br />

16 online languages, 32 configuration languages incl. Asiatic<br />

and Cyrillic character sets<br />

- Language-dependent texts and graphics<br />

User administration (security)<br />

- User-oriented access protection according to requirements<br />

of specific sectors<br />

- Authentication with user name and password<br />

- User-group-specific rights<br />

Signaling system<br />

- Discrete alarms and analog alarms (limit value messages)<br />

as well as the ALARM_S message frame procedure for<br />

SIMATIC S7 and SIMOTION<br />

- Freely definable message classes (e.g., status/fault<br />

messages) for definition of acknowledgment response and<br />

display of alarm events<br />

Message buffer<br />

- Non-volatile, maintenance-free and battery-free message<br />

buffer. The messages are retained even when the Mobile<br />

Panel is disconnected<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/61<br />

2


2<br />

Operator panels<br />

Mobile Panels - 270 series<br />

SIMATIC Mobile Panel 277<br />

■ Function (continued)<br />

■ Integration<br />

Recipe management<br />

The SIMATIC Mobile Panel 277 is generally provided for optional<br />

- With additional data storage (on optional Multimedia<br />

PROFIBUS or PROFINET communication. No distinction is made<br />

Card/SD Card)<br />

at device level.<br />

- Online/offline processing on the panel<br />

This means the device can either be operated<br />

- Storage of recipe data in standard Windows format (CSV)<br />

- External processing using standard tools such as Excel and<br />

for the communication via MPI/PROFIBUS with the<br />

Access is possible<br />

DP cables and connection to the DP "Basic" or "Plus"<br />

connection boxes or<br />

Help texts<br />

for process images, messages and variables.<br />

for the communication via PROFINET with the PN cables<br />

and connection to the PN "Basic" or "Plus" connection<br />

Arithmetic functions<br />

boxes.<br />

Limit value monitoring<br />

A variety of drivers – even for PLCs from other suppliers – are<br />

for reliable process control of inputs and outputs.<br />

supplied as standard.<br />

Indicator light<br />

for machine and plant status indication.<br />

Using the DP connection boxes, the Mobile Panel 277 DP can be<br />

connected to:<br />

Scheduler<br />

for cyclic function processing.<br />

SIMATIC S7-200/-300/-400<br />

Dynamic positioning of objects and dynamic showing/hiding SIMATIC WinAC Software/Slot PLC<br />

of objects<br />

SIMOTION<br />

Permanent window and template concept<br />

SIMATIC S5<br />

- Creation of screen templates:<br />

SIMATIC 505<br />

Simple maintenance and configuration thanks to:<br />

PLCs from other manufacturers<br />

- Backup/restore of the project, operating system, recipe data - Allen Bradley<br />

records and firmware on the optional standard Multimedia - Mitsubishi<br />

Card/SD Card<br />

- Modicon Modbus<br />

- Backup and restoration of configuration, operating system, - GE-Fanuc<br />

recipe data sets and firmware on a <strong>PC</strong> using ProSave<br />

- LG GLOFA GM<br />

- Project transfer/return over MPI/PROFIBUS DP/serial or -OMRON<br />

PROFINET<br />

- Automatic transfer detection<br />

SINUMERIK<br />

- Individual contrast settings<br />

(optionally with "SINUMERIK HMI copy licence WinCC flexible<br />

- Project simulation directly on the configuration computer CE"; "SINUMERIK HMI engineering package WinCC flexible"<br />

is additionally required for configuring;<br />

WinCC flexible options<br />

For further details, see <strong>Catalog</strong> NC 60)<br />

- Sm@rtService for remote operator control and monitoring of<br />

SIMATIC HMI systems based on TCP/IP networks<br />

Using the PN connection boxes, the Mobile Panel 277 can be<br />

- Sm@rtAccess for communication between HMI systems connected to:<br />

based on TCP/IP networks. Remote access to recipe data SIMATIC S7-200/-300/-400<br />

records, passwords and HMI system-specific information,<br />

and much more.<br />

WinAC Software<br />

- O<strong>PC</strong> server: Communication with applications (e. g. MES, SIMOTION<br />

ERP, or applications in the office sector) from various<br />

Over Ethernet (TCP/IP) to a higher-level <strong>PC</strong>, network printer<br />

manufacturers (see HMI Software/runtime software<br />

SIMATIC WinCC flexible/WinCC flexible RT options)<br />

-Audit<br />

Note:<br />

Configuration<br />

Further information can be found under "System interfaces".<br />

Configuration is carried out with the SIMATIC WinCC flexible<br />

Standard or Advanced configuration software (see<br />

SIMATIC WinCC flexible HMI software/engineering software).<br />

SIMATIC WinCC flexible is the logical further development of the<br />

field-proven ProTool family. Projects generated using ProTool<br />

can be easily migrated to WinCC. If WinCC flexible is started<br />

directly from SIMATIC Manager, data in <strong>ST</strong>EP 7 can be accessed<br />

directly when the panel is configured. Double data entry and<br />

data storage are prevented this way.<br />

2/62<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Technical specifications<br />

SIMATIC Mobile Panel 277 8" with integrated<br />

acknowledgment button<br />

Operator panels<br />

Mobile Panels - 270 series<br />

SIMATIC Mobile Panel 277<br />

6AV6 645-0CA01-0AX0 6AV6 645-0CB01-0AX0 6AV6 645-0CC01-0AX0 6AV6 645-0BE02-0AX0<br />

8" with integrated<br />

acknowledgment button<br />

and <strong>ST</strong>OP button<br />

8" with integrated<br />

acknowledgment button,<br />

<strong>ST</strong>OP button, handwheel,<br />

keyswitch and illuminated<br />

pushbutton<br />

10" with integrated<br />

acknowledgment button<br />

and <strong>ST</strong>OP button<br />

Display<br />

Size 7.5" 7.5" 7.5" 10.4"<br />

Display type<br />

Resolution (pixels)<br />

TFT, 65536 colors TFT, 65536 colors TFT, 65536 colors TFT, 65536 colors<br />

Resolution (WxH in pixel)<br />

Backlighting<br />

640 x 4<strong>80</strong> 640 x 4<strong>80</strong> 640 x 4<strong>80</strong> <strong>80</strong>0 x 600<br />

MTBF backlighting<br />

(at 25 °C)<br />

Control elements<br />

about 50,000 hours about 50,000 hours about 50,000 hours about 50,000 hours<br />

Operating options Keys and Touch Keys and Touch Keys and Touch Touch<br />

Function keys,<br />

programmable<br />

Connection for<br />

mouse/keyboard/barcode<br />

reader<br />

18 function keys, 18 with<br />

LEDs<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

18 function keys, 18 with<br />

LEDs<br />

18 function keys, 18 with<br />

LEDs<br />

None<br />

USB / USB / USB USB / USB / USB USB / USB / USB USB / USB / USB<br />

Keyboard<br />

System keys 0<br />

Numeric/alphabetical input<br />

Touch operation<br />

Yes / Yes Yes / Yes Yes / Yes Yes / Yes<br />

Touch screen analog, resistive analog, resistive analog, resistive analog, resistive<br />

Special operator controls<br />

<strong>ST</strong>OP pushbutton No 2-channel, enforced<br />

latching (can be looped<br />

into the emergency stop<br />

circuit)<br />

Acknowledgement button 2-channel, number of 2-channel, number of<br />

positions: 3<br />

positions: 3<br />

2-channel, enforced<br />

latching (can be looped<br />

into the emergency stop<br />

circuit)<br />

2-channel, number of<br />

positions: 3<br />

2-channel, enforced<br />

latching (can be looped<br />

into the emergency stop<br />

circuit)<br />

2-channel, number of<br />

positions: 3<br />

Key-operated switch No No Yes, 3 switch settings No<br />

Illuminated pushbutton No No Yes; Two illuminated<br />

pushbuttons<br />

No<br />

Handwheel<br />

Expansions for operator<br />

control of the process<br />

No No Yes No<br />

DP direct LEDs<br />

(LEDs as S7 output I/O)<br />

F1...F18 F1...F18 F1...F18<br />

DP direct keys<br />

F1...F18, Number of bytes F1...F18, Number of bytes F1...F18, Number of bytes Number of bytes for<br />

(screen buttons and keys as<br />

S7 input I/O)<br />

Supply voltage<br />

Input voltage<br />

for configurable buttons: 10 for configurable buttons: 10 for configurable buttons: 10 configurable buttons: 10<br />

Supply voltage<br />

Backup battery<br />

via connection box via connection box via connection box via connection box, DC<br />

Battery operation maximum buffer time maximum buffer time maximum buffer time 10 maximum buffer time<br />

10 min<br />

10 min<br />

min<br />

10 min<br />

Charging duration 5h<br />

Number of loading cycles,<br />

min<br />

Processor<br />

500<br />

Processor<br />

Memory<br />

ARM, 520 MHz ARM, 520 MHz ARM, 520 MHz ARM, 520<br />

Type Flash / RAM Flash / RAM Flash / RAM Flash / RAM<br />

Usable memory for user data 6 MB usable memory for 6 MB usable memory for 6 MB usable memory for 6 MB usable memory for<br />

user data<br />

user data<br />

user data<br />

user data<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/63<br />

2


2<br />

Operator panels<br />

Mobile Panels - 270 series<br />

SIMATIC Mobile Panel 277<br />

■ Technical specifications (continued)<br />

SIMATIC Mobile Panel 277 8" with integrated<br />

acknowledgment button<br />

Type of output<br />

LED colors Green Green Green<br />

Time of day<br />

Clock<br />

Type Hardware clock, battery<br />

backup, synchronizable<br />

Interfaces<br />

Interfaces 1 x RS422, 1 x RS485,<br />

1 x Ethernet (RJ45)<br />

(max. 12 Mbit/s)<br />

2/64<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV6 645-0CA01-0AX0 6AV6 645-0CB01-0AX0 6AV6 645-0CC01-0AX0 6AV6 645-0BE02-0AX0<br />

8" with integrated<br />

acknowledgment button<br />

and <strong>ST</strong>OP button<br />

Hardware clock, battery<br />

backup, synchronizable<br />

1 x RS422, 1 x RS485,<br />

1 x Ethernet (RJ45)<br />

(max. 12 Mbit/s)<br />

8" with integrated<br />

acknowledgment button,<br />

<strong>ST</strong>OP button, handwheel,<br />

keyswitch and illuminated<br />

pushbutton<br />

Hardware clock, battery<br />

backup, synchronizable<br />

1 x RS422, 1 x RS485,<br />

1 x Ethernet (RJ45)<br />

(max. 12 Mbit/s)<br />

10" with integrated<br />

acknowledgment button<br />

and <strong>ST</strong>OP button<br />

Hardware clock, battery<br />

backup, synchronizable<br />

1 x RS422, 1 x RS485,<br />

1 x Ethernet (RJ45)<br />

(max. 12 Mbit/s)<br />

USB port 1 x USB 1 x USB 1 x USB 1 x USB<br />

Multi Media Card slot 1 MMC/SD card slot 1 MMC/SD card slot 1 MMC/SD card slot<br />

Multimedia card<br />

Industrial Ethernet<br />

combined<br />

Industrial Ethernet interface<br />

Protocols<br />

1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45)<br />

PROFINET Yes<br />

PROFINET IO<br />

Ambient conditions<br />

Operating temperature<br />

Yes<br />

Operation<br />

Storage/transport temperature<br />

0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C<br />

Transport, storage<br />

Relative humidity<br />

-20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C<br />

max. relative humidity <strong>80</strong> % <strong>80</strong> % <strong>80</strong> % <strong>80</strong> %<br />

Drop height<br />

Degree and class of<br />

protection<br />

1.2 m 1.2 m 1.2 m 1m<br />

IP65 housing<br />

Standards, approvals,<br />

certificates<br />

Yes Yes Yes Yes<br />

Certifications CE, cULus, C-TICK, SIBE CE, cULus, C-TICK, SIBE CE, cULus, C-TICK, SIBE CE, cULus, C-TICK, SIBE<br />

Performance level acc. to<br />

EN ISO 13849-1<br />

d d d d<br />

Safety category according to Safety category according Safety category according Safety category according Safety category according<br />

EN954-1<br />

to EN954-1 (enabling to EN954-1 (enabling to EN954-1 (enabling to EN954-1 (enabling<br />

button, <strong>ST</strong>OP button if button, <strong>ST</strong>OP button if button, <strong>ST</strong>OP button if button, <strong>ST</strong>OP button if<br />

Operating systems<br />

present) 3<br />

present) 3<br />

present) 3<br />

present) 3<br />

Operating system<br />

Configuration<br />

Configuration software<br />

Windows CE Windows CE Windows CE Windows CE<br />

Configuration tool see "Configuration overview" from page 2/3


■ Technical specifications (continued)<br />

SIMATIC Mobile Panel 277 8" with integrated<br />

acknowledgment button<br />

Operator panels<br />

Mobile Panels - 270 series<br />

SIMATIC Mobile Panel 277<br />

Functionality under WinCC<br />

flexible/WinCC (TIA portal)<br />

Applications/options see chapter 4: HMI software/SIMATIC WinCC flexible options and SIMATIC WinC (TIA portal) options<br />

Number of Visual Basic<br />

Scripts<br />

50 50 50 50<br />

Task planner Yes Yes Yes Yes<br />

Help system Yes Yes Yes Yes<br />

Status/control<br />

With alarm logging system<br />

(incl. buffer and<br />

acknowledgment)<br />

with SIMATIC S7 with SIMATIC S7 with SIMATIC S7 with SIMATIC S7<br />

Number of messages 4000 4 000 4000 4000<br />

Bit messages Yes Yes Yes Yes<br />

Analog messages Yes Yes Yes Yes<br />

Message buffer Ring buffer<br />

(n x 512 entries), retentive,<br />

maintenance-free<br />

Ring buffer<br />

(n x 512 entries), retentive,<br />

maintenance-free<br />

Ring buffer<br />

(n x 512 entries), retentive,<br />

maintenance-free<br />

Recipes<br />

Recipes 300 300 300 300<br />

Data records per recipe 500 500 500 200<br />

Entries per data record 1000 1000 1000 1000<br />

Recipe memory 64 KB integrated Flash,<br />

expandable<br />

64 KB integrated Flash,<br />

expandable<br />

64 KB integrated Flash,<br />

expandable<br />

Ring buffer<br />

(n x 512 entries), retentive,<br />

maintenance-free<br />

64 KB integrated Flash,<br />

expandable<br />

Number of process images<br />

Process images 500 500 500 500<br />

Variables 2048 2 048 2048 2048<br />

Limit values Yes Yes Yes Yes<br />

Multiplexing<br />

Image elements<br />

Yes Yes Yes Yes<br />

Text objects 10,000 text elements 10,000 text elements 10,000 text elements 10,000 text elements<br />

Graphic object Bit maps, icons, vector Bit maps, icons, vector Bit maps, icons, vector Bit maps, icons, vector<br />

graphics<br />

graphics<br />

graphics<br />

graphics<br />

dynamic objects Diagrams, bar graphs,<br />

sliders, analog display,<br />

invisible buttons<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV6 645-0CA01-0AX0 6AV6 645-0CB01-0AX0 6AV6 645-0CC01-0AX0 6AV6 645-0BE02-0AX0<br />

8" with integrated<br />

acknowledgment button<br />

and <strong>ST</strong>OP button<br />

Diagrams, bar graphs,<br />

sliders, analog display,<br />

invisible buttons<br />

8" with integrated<br />

acknowledgment button,<br />

<strong>ST</strong>OP button, handwheel,<br />

keyswitch and illuminated<br />

pushbutton<br />

Diagrams, bar graphs,<br />

sliders, analog display,<br />

invisible buttons<br />

10" with integrated<br />

acknowledgment button<br />

and <strong>ST</strong>OP button<br />

Diagrams, bar graphs,<br />

sliders, analog display,<br />

invisible buttons<br />

Lists<br />

Text lists 500 500 500 500<br />

Graphic list 400 400 400 400<br />

Libraries<br />

Archiving<br />

Yes Yes Yes Yes<br />

Number of archives per<br />

project<br />

20 20 20 20<br />

Number of measuring<br />

points per project<br />

20 20 20 20<br />

Number of entries per<br />

archive<br />

10 000 10 000 10 000 10 000<br />

Memory location<br />

Security<br />

Multi Media Card Multi Media Card Multi Media Card Multi Media Card<br />

Number of user groups 50 50 50 50<br />

Passwords exportable Yes Yes Yes Yes<br />

Number of user rights<br />

Data carrier support<br />

32 32 32 32<br />

Multimedia Card Yes Yes Yes Yes<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/65<br />

2


2<br />

Operator panels<br />

Mobile Panels - 270 series<br />

SIMATIC Mobile Panel 277<br />

■ Technical specifications (continued)<br />

SIMATIC Mobile Panel 277 8" with integrated<br />

acknowledgment button<br />

Recording<br />

Recording/Printing Alarms, report (shift report),<br />

color print, hardcopy<br />

2/66<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Alarms, report (shift report),<br />

color print, hardcopy<br />

Alarms, report (shift report),<br />

color print, hardcopy<br />

Alarms, report (shift report),<br />

color print, hardcopy,<br />

PROFINET<br />

Fonts<br />

Keyboard fonts US American (English) US American (English) US American (English) US American (English)<br />

Languages<br />

Configuration languages D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified",<br />

DK, FIN, GR, J, KP / ROK,<br />

NL, N, PL, P, RUS, S, CZ /<br />

SK, TR, H<br />

Character sets Tahoma, Arial, Courier<br />

New, WinCC flexible<br />

Standard, symbol<br />

languages, all freely<br />

scalable<br />

Transfer (upload/download)<br />

Transfer of configuration MPI/PROFIBUS DP, USB,<br />

Ethernet, automatic transfer<br />

recognition<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV6 645-0CA01-0AX0 6AV6 645-0CB01-0AX0 6AV6 645-0CC01-0AX0 6AV6 645-0BE02-0AX0<br />

8" with integrated<br />

acknowledgment button<br />

and <strong>ST</strong>OP button<br />

D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified",<br />

DK, FIN, GR, J, KP / ROK,<br />

NL, N, PL, P, RUS, S, CZ /<br />

SK, TR, H<br />

Tahoma, Arial, Courier<br />

New, WinCC flexible<br />

Standard, symbol<br />

languages, all freely<br />

scalable<br />

MPI/PROFIBUS DP, USB,<br />

Ethernet, automatic transfer<br />

recognition<br />

8" with integrated<br />

acknowledgment button,<br />

<strong>ST</strong>OP button, handwheel,<br />

keyswitch and illuminated<br />

pushbutton<br />

D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified",<br />

DK, FIN, GR, J, KP / ROK,<br />

NL, N, PL, P, RUS, S, CZ /<br />

SK, TR, H<br />

Tahoma, Arial, Courier<br />

New, WinCC flexible<br />

Standard, symbol<br />

languages, all freely<br />

scalable<br />

MPI/PROFIBUS DP, USB,<br />

Ethernet, automatic transfer<br />

recognition<br />

10" with integrated<br />

acknowledgment button<br />

and <strong>ST</strong>OP button<br />

D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified",<br />

DK, FIN, GR, J, KP / ROK,<br />

NL, N, PL, P, RUS, S, CZ /<br />

SK, TR, H<br />

Tahoma, Arial, Courier<br />

New, WinCC flexible<br />

Standard, symbol<br />

languages, all freely<br />

scalable<br />

MPI/PROFIBUS DP, USB,<br />

Ethernet, automatic transfer<br />

recognition<br />

Process coupling<br />

Connection to controller<br />

I/O<br />

see "System interfaces" from page 2/178<br />

I/O devices<br />

Mechanics/material<br />

Printer, barcode reader Printer, barcode reader Printer, barcode reader Printer, barcode reader<br />

Type of housing (front)<br />

Dimensions and weight<br />

Dimensions<br />

Plastic Plastic Plastic Plastic<br />

Housing diameter/<br />

depth (mm)<br />

Weight<br />

Dia 290 mm / D 103 mm Dia 290 mm / D 103 mm Dia 290 mm / D 103 mm<br />

Weight 1.7 kg 1.7 kg 1.7 kg 2.3 kg


with SIMATIC WinCC flexible<br />

Documentation<br />

(to be ordered separately)<br />

Operating Instructions for<br />

Mobile Panel 277<br />

see HMI software<br />

German 6AV6 691-1DL01-0AA0<br />

English 6AV6 691-1DL01-0AB0<br />

French 6AV6 691-1DL01-0AC0<br />

Italian 6AV6 691-1DL01-0AD0<br />

Spanish<br />

User Manual WinCC flexible<br />

Compact/Standard/Advanced<br />

6AV6 691-1DL01-0AE0<br />

German 6AV6 691-1AB01-3AA0<br />

English 6AV6 691-1AB01-3AB0<br />

French 6AV6 691-1AB01-3AC0<br />

Italian 6AV6 691-1AB01-3AD0<br />

Spanish<br />

WinCC flexible Communication<br />

User Manual<br />

6AV6 691-1AB01-3AE0<br />

German 6AV6 691-1CA01-3AA0<br />

English 6AV6 691-1CA01-3AB0<br />

French 6AV6 691-1CA01-3AC0<br />

Italian 6AV6 691-1CA01-3AD0<br />

Spanish 6AV6 691-1CA01-3AE0<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Mobile Panels - 270 series<br />

SIMATIC Mobile Panel 277<br />

■ Ordering data Order No. Order No.<br />

SIMATIC Mobile Panel 277 8" 1)<br />

SIMATIC HMI Manual Collection B 6AV6 691-1SA01-0AX0<br />

With integrated<br />

acknowledgement button<br />

With integrated acknowledgement<br />

button and <strong>ST</strong>OP<br />

pushbutton<br />

With integrated acknowledgement<br />

button, <strong>ST</strong>OP<br />

pushbutton, handwheel,<br />

key-operated switch and two<br />

E<br />

E<br />

E<br />

6AV6 645-0CA01-0AX0<br />

6AV6 645-0CB01-0AX0<br />

6AV6 645-0CC01-0AX0<br />

Electronic documentation,<br />

on DVD<br />

5 languages (English, French,<br />

German, Italian and Spanish);<br />

contains: all currently available<br />

user manuals, manuals and<br />

communication manuals for<br />

SIMATIC HMI<br />

illuminated pushbuttons<br />

System components for<br />

SIMATIC Mobile Panel 277 10"<br />

Mobile Panels<br />

With integrated acknowledgement<br />

button and <strong>ST</strong>OP<br />

pushbutton<br />

E 6AV6 645-0BE02-0AX0<br />

DP connection box for Mobile<br />

Panels (MPI/PROFIBUS)<br />

Basic 6AV6 671-5AE00-0AX0<br />

Configuration<br />

Plus<br />

PN connection box for Mobile<br />

Panel<br />

(PROFINET)<br />

6AV6 671-5AE10-0AX0<br />

Basic 6AV6 671-5AE01-0AX0<br />

Plus<br />

DP connecting cable<br />

(MPI/PROFIBUS)<br />

Standard cables<br />

6AV6 671-5AE11-0AX0<br />

2 m 6XV1 440-4AH20<br />

5 m 6XV1 440-4AH50<br />

10 m 6XV1 440-4AN10<br />

15 m 6XV1 440-4AN15<br />

25 m<br />

Intermediate lengths<br />

6XV1 440-4AN25<br />

2)<br />

8 m 6XV1 440-4AH<strong>80</strong><br />

20 m<br />

PN connecting cable<br />

(PROFINET)<br />

Standard cables<br />

6XV1 440-4AN20<br />

2 m 6XV1 440-4BH20<br />

5 m 6XV1 440-4BH50<br />

8 m 6XV1 440-4BH<strong>80</strong><br />

10 m 6XV1 440-4BN10<br />

15 m 6XV1 440-4BN15<br />

20 m 6XV1 440-4BN20<br />

25 m 6XV1 440-4BN25<br />

Accessories for Mobile Panels see HMI accessories<br />

1) The system components (connecting cables and connection boxes)<br />

must be ordered separately.<br />

2) Delivery time approximately 6 weeks<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/67<br />

2


2<br />

Operator panels<br />

Mobile Panels - 270 series<br />

SIMATIC Mobile Panel 277<br />

■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical<br />

specifications.<br />

Mobile Panel 277 8" – front and side view<br />

Mobile Panel 277 10" – front and side view<br />

2/68<br />

9<br />

155<br />

212<br />

117<br />

Ø 290<br />

350<br />

159<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

320<br />

8°<br />

8°<br />

103<br />

129<br />

103<br />

129<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00277<br />

G_<strong>ST</strong><strong>80</strong>_XX_00354<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-mobile-panels<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.


■ Overview<br />

■ Function<br />

Input/output fields<br />

for displaying and changing of process values.<br />

Function keys<br />

are used for directly triggering functions and actions. Up to<br />

16 functions can be configured simultaneously on function<br />

keys. The function keys can also be used directly as<br />

PROFINET IO.<br />

The function keys can also be reconfigured as system keys.<br />

A frequently used function such as "Acknowledge alarm" can<br />

thus be assigned to a function key.<br />

Auxiliary operator controls<br />

such as handwheels, key switches and illuminated<br />

pushbuttons can be assigned with a variable or as a direct<br />

actuation via PROFINET IO (direct keys).<br />

Buttons<br />

are used for direct triggering of functions and actions. Up to<br />

16 functions can be configured simultaneously on buttons.<br />

Graphics<br />

can be used as symbols instead of text for "labeling" function<br />

keys or buttons. They can also be used as full-screen<br />

background images.<br />

In the configuration software, a comprehensive library is<br />

available containing graphics and a wide variety of objects. All<br />

editors with an OLE interface can be used as graphic editors<br />

(such as PaintShop, Designer or CorelDraw).<br />

Vector graphics;<br />

simple geometric basic forms (e. g. lines, circles and<br />

rectangles) can be created directly in the configuration<br />

software.<br />

Text fields<br />

for labeling function keys, process displays, and process<br />

values in any font size.<br />

Trend views and bars<br />

are used for the graphic display of dynamic values.<br />

Display selection from the controller<br />

permits operator prompting from the controller.<br />

Presentation of HTML documents with MS Pocket Internet<br />

Explorer.<br />

Visual Basic Script, flexibility thanks to the implementation of<br />

new functions including linking to variables (comparison<br />

operations, loops, etc.).<br />

Language switching<br />

16 online languages, 32 configuration languages incl. Asiatic<br />

and Cyrillic character sets<br />

- Language-dependent texts and graphics<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Mobile Panels — 270 series<br />

SIMATIC Mobile Panel 277(F) IWLAN<br />

User administration (security)<br />

- User-oriented access protection according to requirements<br />

of specific sectors<br />

- Authentication with user name and password<br />

- User-group-specific rights<br />

Signaling system<br />

- Discrete and analog alarms (edge alarms) as well as the<br />

ALARM_S message frame procedure for SIMATIC S7<br />

- Freely definable message classes (e. g. status/fault<br />

messages) for definition of acknowledgment response and<br />

display of alarm events<br />

Message buffer<br />

- Non-volatile, maintenance-free and battery-free message<br />

buffer. The messages remain stored when the mobile panel<br />

has the battery removed as well<br />

Recipe management<br />

- With additional data storage (on optional MultiMedia<br />

Card/SD Card)<br />

- Online/offline processing on the panel<br />

- Storage of recipe data in standard Windows format (CSV)<br />

- External processing using standard tools such as Excel and<br />

Access is possible<br />

Help texts<br />

for process images, messages and variables.<br />

Arithmetic functions<br />

Limit value monitoring<br />

for reliable process control of inputs and outputs.<br />

Indicator light<br />

for machine and plant status indication.<br />

Scheduler<br />

for cyclic function processing.<br />

Dynamic positioning of objects and dynamic showing/hiding<br />

of objects<br />

Permanent window and template concept<br />

- Creation of screen templates:<br />

Simple maintenance and configuration thanks to:<br />

- Backup/restore of the project, operating system, recipe data<br />

records and firmware on the optional standard multi-media<br />

card/SD card<br />

- Backup and restoration of configuration, operating system,<br />

recipe data sets and firmware on a <strong>PC</strong> using ProSave<br />

- Project transfer/return transfer via PROFINET/WLAN<br />

- Automatic transfer detection<br />

- Individual brightness setting<br />

- Project simulation directly on the configuration computer<br />

WinCC flexible options<br />

- Sm@rtService for remote operator control and monitoring of<br />

SIMATIC HMI systems based on TCP/IP networks<br />

- Sm@rtAccess for communication between HMI systems<br />

based on TCP/IP networks. Remote access to recipe data<br />

records, passwords and HMI system-specific information,<br />

and much more. (Mobile Panel 277F IWLAN as server: View<br />

only)<br />

- O<strong>PC</strong> server: Communication with applications (e. g. MES,<br />

ERP, or applications in the office sector) from various<br />

manufacturers (see HMI software/runtime software<br />

SIMATIC WinCC flexible/WinCC flexible RT options)<br />

-Audit<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/69<br />

2


2<br />

Operator panels<br />

Mobile Panels — 270 series<br />

SIMATIC Mobile Panel 277(F) IWLAN<br />

■ Function (continued)<br />

Configuration<br />

Configuration is carried out with the SIMATIC WinCC flexible<br />

Standard or Advanced configuration software (see<br />

SIMATIC WinCC flexible HMI software/engineering software).<br />

SIMATIC WinCC flexible is the logical further development of the<br />

field-proven ProTool family. Projects generated using ProTool<br />

can be easily migrated to WinCC. If WinCC flexible is started<br />

directly from SIMATIC Manager, data in <strong>ST</strong>EP 7 can be accessed<br />

directly when the panel is configured. Duplicated data input and<br />

data management is, therefore, avoided.<br />

2/70<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

IWLAN infrastructure<br />

The required IWLAN infrastructure is set up with the IWLAN<br />

Access Points SCALANCE W-7<strong>80</strong>, preferably with the version<br />

SCALANCE W786-2RR, which fully supports all possible applications<br />

of the Mobile Panel 277(F) IWLAN. For operating a plant<br />

without fail-safe communication, the version SCALANCE<br />

W786-1PRO can also be used. The i<strong>PC</strong>F functionality (rapid<br />

roaming = fast, uninterrupted switchover between several<br />

access points) is only available with V2 panels upwards.<br />

The Access Point provides an Industrial Ethernet interface for<br />

connection to the wired network.<br />

In addition to a reliable radio link, the SCALANCE W-7<strong>80</strong> Access<br />

Points stand out due to their optimum support of standardized<br />

IT mechanisms:<br />

IEEE <strong>80</strong>2.11b/ g/ a/ h for different frequency ranges<br />

IEEE <strong>80</strong>2.11e for multimedia, wireless multimedia (WMM) 1)<br />

IEEE <strong>80</strong>2.11i for security 1)<br />

Construction of redundant networks with the Rapid Spanning<br />

Tree Protocol (R<strong>ST</strong>P)<br />

Virtual networks (VLAN) to logically separate, for example,<br />

different user groups<br />

Sending the log entries of the SCALANCE W devices to a<br />

Syslog server<br />

1) Not supported by Mobile Panel Wireless


■ Integration<br />

The SIMATIC Mobile Panel 277(F) IWLAN communicates via the<br />

WLAN Standard IEEE <strong>80</strong>2.11 a(b/g) via PROFINET. The Mobile<br />

Panel 277F IWLAN devices also support PROFIsafe communication.<br />

There are five device versions with V2:<br />

For mobile operation and monitoring via WLAN:<br />

Mobile Panel 277 IWLAN V2<br />

Mobile Panel 277 IWLAN V2 with handwheel, key switch and<br />

illuminated pushbuttons<br />

As fail-safe device for safety-oriented operation as well:<br />

Mobile Panel 277F IWLAN V2 with acknowledgement button<br />

and emergency stop button<br />

Mobile Panel 277F IWLAN V2 with acknowledgement button,<br />

emergency stop button, handwheel, key switch and<br />

illuminated pushbuttons<br />

Mobile Panel 277F IWLAN RFID Tag (for V2 only)<br />

For the versions Mobile Panel 277F IWLAN (PROFIsafe), the<br />

following system prerequisites apply:<br />

The Mobile Panel must be connected as a safe device<br />

(PROFIsafe, Distributed Safety)<br />

Use of a SIMATIC F-CPU<br />

5 GHz<br />

SIMATIC<br />

SIMATIC Mobile Panel<br />

frequency<br />

band<br />

F-CPU<br />

(Distributed<br />

(IEEE <strong>80</strong>2.11a) Safety)<br />

277 IWLAN Only WLAN<br />

utilization (HMI)<br />

x -<br />

When using<br />

transponders<br />

! -<br />

When using<br />

Profinet IO<br />

x -<br />

277F IWLAN<br />

(fail-safe)<br />

277F IWLAN<br />

(RFID Tag)<br />

(fail-safe)<br />

X = Recommended<br />

! = Requirement<br />

- = Not required<br />

- -<br />

!<br />

-<br />

!<br />

x !<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Mobile Panels — 270 series<br />

SIMATIC Mobile Panel 277(F) IWLAN<br />

The Mobile Panel 277(F) IWLAN can be connected to:<br />

SIMATIC S7-200/-300/-400 (one F-CPU required for<br />

integrating the Mobile Panel 277F IWLAN and SIMOTION<br />

(Mobile Panel 277 IWLAN V2 or higher, or Mobile Panel<br />

277FI WLAN V2 or higher (WinCC flexible 2008 SP3 or<br />

higher))<br />

Note:<br />

Further information can be found under "System interfaces". The<br />

function manuals "Fail-Safe Operation of the Mobile Panel 277F<br />

IWLAN" are available for downloading in English, German, and<br />

Japanese.<br />

http://support.automation.siemens.com/WW/view/en/31255853<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/71<br />

2


2<br />

Operator panels<br />

Mobile Panels — 270 series<br />

SIMATIC Mobile Panel 277(F) IWLAN<br />

■ Technical specifications<br />

2/72<br />

6AV6 645-0DD01-<br />

0AX1<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6AV6 645-0DE01-<br />

0AX1<br />

6AV6 645-0EB01-<br />

0AX1<br />

6AV6 645-0EC01-<br />

0AX1<br />

6AV6 645-0EF01-<br />

0AX1<br />

Display<br />

Size 7.5" 7.5" 7.5" 7.5" 7.5"<br />

Display type<br />

Resolution (pixels)<br />

TFT, 65536 colors TFT, 65536 colors TFT, 65536 colors TFT, 65536 colors TFT, 65536 colors<br />

Resolution (WxH in<br />

pixel)<br />

Backlighting<br />

640 x 4<strong>80</strong> 640 x 4<strong>80</strong> 640 x 4<strong>80</strong> 640 x 4<strong>80</strong> 640 x 4<strong>80</strong><br />

MTBF backlighting<br />

(at 25 °C)<br />

Control elements<br />

about 50,000 hours about 50,000 hours about 50,000 hours about 50,000 hours about 50,000 hours<br />

Operating options Keys and Touch Keys and Touch Keys and Touch Keys and Touch Keys and Touch<br />

Function keys,<br />

programmable<br />

Connection for<br />

mouse/keyboard/barcod<br />

e reader<br />

18 function keys,<br />

18 with LEDs<br />

18 function keys,<br />

18 with LEDs<br />

18 function keys,<br />

18 with LEDs<br />

18 function keys,<br />

18 with LEDs<br />

18 function keys,<br />

18 with LEDs<br />

USB / USB / USB USB / USB / USB USB / USB / USB USB / USB / USB USB / USB / USB<br />

Keyboard<br />

Numeric/alphabetical<br />

input<br />

Touch operation<br />

Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes<br />

Touch screen<br />

Special operator<br />

controls<br />

analog, resistive analog, resistive analog, resistive analog, resistive analog, resistive<br />

Emergency stop<br />

2-channel, positive 2-channel, positive 2-channel, positive<br />

button<br />

latching<br />

latching<br />

latching<br />

Acknowledgement<br />

2-channel, number of 2-channel, number of 2-channel, number of<br />

button<br />

positions: 3<br />

positions: 3<br />

positions: 3<br />

Key-operated switch Yes, 3 switch settings Yes, 3 switch settings Yes, 3 switch settings<br />

Illuminated pushbutton Yes Yes Yes<br />

Handwheel<br />

Expansions for<br />

operator control of the<br />

process<br />

Yes Yes Yes<br />

DP direct LEDs<br />

(LEDs as S7 output I/O)<br />

F1...F18 F1...F18 F1...F18 F1...F18 F1...F18<br />

DP direct keys (screen<br />

buttons and keys as S7<br />

input I/O )<br />

F1...F18, Number of<br />

bytes for configurable<br />

buttons: 10<br />

F1...F18, Number of<br />

bytes for configurable<br />

buttons: 10<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

F1...F18, Number of<br />

bytes for configurable<br />

buttons: 10<br />

F1...F18, Number of<br />

bytes for configurable<br />

buttons: 10<br />

F1...F18, Number of<br />

bytes for configurable<br />

buttons: 10<br />

Supply voltage<br />

Via charging station Yes Yes Yes Yes Yes<br />

Via table power supply<br />

Input voltage<br />

Yes Yes Yes Yes Yes<br />

Supply voltage<br />

Main battery<br />

DC DC DC DC DC<br />

Rated voltage 7.2 V 7.2 V 7.2 V 7.2 V 7.2 V<br />

Capacity 5100mA<strong>·</strong>h 5 100 mA<strong>·</strong>h 5100mA<strong>·</strong>h 5100mA<strong>·</strong>h 5100mA<strong>·</strong>h<br />

Number of loading<br />

cycles, min<br />

500 500 500 500 500<br />

Charging time, typ. 4h 4h 4h 4h 4h<br />

Operating time, typ. 4h 4h 4h 4h 4h<br />

Display for battery<br />

capacity<br />

Yes Yes Yes Yes Yes<br />

Energy-saving mode Yes Yes Yes Yes Yes<br />

Battery exchange in<br />

operation<br />

Yes Yes Yes Yes Yes


■ Technical specifications (continued)<br />

Operator panels<br />

Mobile Panels — 270 series<br />

SIMATIC Mobile Panel 277(F) IWLAN<br />

Processor<br />

Processor<br />

Memory<br />

ARM, 520 MHz ARM, 520 MHz ARM, 520 MHz ARM, 520 MHz ARM, 520 MHz<br />

Type Flash / RAM Flash / RAM Flash / RAM Flash / RAM Flash / RAM<br />

Usable memory for user<br />

data<br />

6 MB usable memory<br />

for user data<br />

6 MB usable memory<br />

for user data<br />

6 MB usable memory<br />

for user data<br />

6 MB usable memory<br />

for user data<br />

Type of output<br />

Status LEDs Yes Yes Yes Yes Yes<br />

LED for safe Yes Yes Yes<br />

LED for communication<br />

Yes Yes Yes Yes Yes<br />

LED for battery Yes Yes Yes Yes Yes<br />

Vibrations Yes Yes Yes Yes Yes<br />

Time of day<br />

Clock<br />

Type Hardware clock,<br />

battery backup,<br />

synchronizable<br />

Hardware clock,<br />

battery backup,<br />

synchronizable<br />

Hardware clock,<br />

battery backup,<br />

synchronizable<br />

Hardware clock,<br />

battery backup,<br />

synchronizable<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6 MB usable memory<br />

for user data<br />

Hardware clock,<br />

battery backup,<br />

synchronizable<br />

Interfaces<br />

Interfaces 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45)<br />

USB port 1 x USB 1 x USB 1 x USB 1 x USB 1 x USB<br />

Multi Media Card slot<br />

Industrial Ethernet<br />

1 MMC/SD card slot 1 MMC/SD card slot 1 MMC/SD card slot 1 MMC/SD card slot 1 MMC/SD card slot<br />

Industrial Ethernet<br />

interface<br />

1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45)<br />

Wireless LAN Yes Yes Yes Yes Yes<br />

Supports standards according to<br />

according to<br />

according to<br />

according to<br />

according to<br />

IEEE <strong>80</strong>2.11a<br />

IEEE <strong>80</strong>2.11a<br />

IEEE <strong>80</strong>2.11a<br />

IEEE <strong>80</strong>2.11a<br />

IEEE <strong>80</strong>2.11a<br />

Supported channels<br />

(according to<br />

IEEE <strong>80</strong>2.11a)<br />

Supported channels<br />

(according to<br />

IEEE <strong>80</strong>2.11b and<br />

IEEE <strong>80</strong>2.1g)<br />

Country approval<br />

(radio)<br />

6AV6 645-0DD01-<br />

0AX1<br />

Channel 34, channel<br />

36, channel 38,<br />

channel 40, channel<br />

42, channel 44,<br />

channel 46, channel<br />

48, channel 52,<br />

channel 56, channel<br />

60, channel 64,<br />

channel 149, channel<br />

153, channel 157,<br />

channel 161<br />

Channels 1 to 11,<br />

channel 12, channel<br />

13, channel 14<br />

Australia, Austria,<br />

Belgium, Bulgaria,<br />

Canada, China,<br />

Cyprus, Denmark,<br />

Estonia, Finland,<br />

France, Germany, UK,<br />

Greece, Hungary,<br />

Ireland, Iceland, Italy,<br />

Japan, Latvia, Liechtenstein,<br />

Lithuania,<br />

Luxemburg, Malta, the<br />

Netherlands, Norway,<br />

Poland, Portugal,<br />

Rumania, Sweden,<br />

Switzerland, Slovakia,<br />

Slovenia, Spain, South<br />

Korea, South Africa,<br />

Taiwan, Czech<br />

Republic, Turkey<br />

6AV6 645-0DE01-<br />

0AX1<br />

Channel 34, channel<br />

36, channel 38,<br />

channel 40, channel<br />

42, channel 44,<br />

channel 46, channel<br />

48, channel 52,<br />

channel 56, channel<br />

60, channel 64,<br />

channel 149, channel<br />

153, channel 157,<br />

channel 161<br />

Channels 1 to 11,<br />

channel 12, channel<br />

13, channel 14<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Australia, Austria,<br />

Belgium, Bulgaria,<br />

Canada, China,<br />

Cyprus, Denmark,<br />

Estonia, Finland,<br />

France, Germany, UK,<br />

Greece, Hungary,<br />

Ireland, Iceland, Italy,<br />

Japan, Latvia, Liechtenstein,<br />

Lithuania,<br />

Luxemburg, Malta, the<br />

Netherlands, Norway,<br />

Poland, Portugal,<br />

Rumania, Sweden,<br />

Switzerland, Slovakia,<br />

Slovenia, Spain, South<br />

Korea, South Africa,<br />

Taiwan, Czech<br />

Republic, Turkey<br />

6AV6 645-0EB01-<br />

0AX1<br />

Channel 34, channel<br />

36, channel 38,<br />

channel 40, channel<br />

42, channel 44,<br />

channel 46, channel<br />

48, channel 52,<br />

channel 56, channel<br />

60, channel 64,<br />

channel 149, channel<br />

153, channel 157,<br />

channel 161<br />

Channels 1 to 11,<br />

channel 12, channel<br />

13, channel 14<br />

Australia, Austria,<br />

Belgium, Bulgaria,<br />

Canada, China,<br />

Cyprus, Denmark,<br />

Estonia, Finland,<br />

France, Germany, UK,<br />

Greece, Hungary,<br />

Ireland, Iceland, Italy,<br />

Japan, Latvia, Liechtenstein,<br />

Lithuania,<br />

Luxemburg, Malta, the<br />

Netherlands, Norway,<br />

Poland, Portugal,<br />

Rumania, Sweden,<br />

Switzerland, Slovakia,<br />

Slovenia, Spain, South<br />

Korea, South Africa,<br />

Taiwan, Czech<br />

Republic, Turkey<br />

6AV6 645-0EC01-<br />

0AX1<br />

Channel 34, channel<br />

36, channel 38,<br />

channel 40, channel<br />

42, channel 44,<br />

channel 46, channel<br />

48, channel 52,<br />

channel 56, channel<br />

60, channel 64,<br />

channel 149, channel<br />

153, channel 157,<br />

channel 161<br />

Channels 1 to 11,<br />

channel 12, channel<br />

13, channel 14<br />

Australia, Austria,<br />

Belgium, Bulgaria,<br />

Canada, China,<br />

Cyprus, Denmark,<br />

Estonia, Finland,<br />

France, Germany, UK,<br />

Greece, Hungary,<br />

Ireland, Iceland, Italy,<br />

Japan, Latvia, Liechtenstein,<br />

Lithuania,<br />

Luxemburg, Malta, the<br />

Netherlands, Norway,<br />

Poland, Portugal,<br />

Rumania, Sweden,<br />

Switzerland, Slovakia,<br />

Slovenia, Spain, South<br />

Korea, South Africa,<br />

Taiwan, Czech<br />

Republic, Turkey<br />

6AV6 645-0EF01-<br />

0AX1<br />

Channel 34, channel<br />

36, channel 38,<br />

channel 40, channel<br />

42, channel 44,<br />

channel 46, channel<br />

48, channel 52,<br />

channel 56, channel<br />

60, channel 64,<br />

channel 149, channel<br />

153, channel 157,<br />

channel 161<br />

Channels 1 to 11,<br />

channel 12, channel<br />

13, channel 14<br />

Encryption WEP, WPA WEP, WPA WEP, WPA WEP, WPA WEP, WPA<br />

Supports rapid<br />

roaming<br />

Yes Yes Yes Yes Yes<br />

Australia, Austria,<br />

Belgium, Bulgaria,<br />

Canada, China,<br />

Cyprus, Denmark,<br />

Estonia, Finland,<br />

France, Germany, UK,<br />

Greece, Hungary,<br />

Ireland, Iceland, Italy,<br />

Japan, Latvia, Liechtenstein,<br />

Lithuania,<br />

Luxemburg, Malta, the<br />

Netherlands, Norway,<br />

Poland, Portugal,<br />

Rumania, Sweden,<br />

Switzerland, Slovakia,<br />

Slovenia, Spain, South<br />

Korea, South Africa,<br />

Taiwan, Czech<br />

Republic, Turkey<br />

2/73<br />

2


2<br />

Operator panels<br />

Mobile Panels — 270 series<br />

SIMATIC Mobile Panel 277(F) IWLAN<br />

■ Technical specifications (continued)<br />

Protocols<br />

PROFINET Yes Yes Yes Yes Yes<br />

PROFINET IO Yes Yes Yes Yes Yes<br />

PROFIsafe Yes Yes Yes<br />

EMC<br />

Emission of radio<br />

interference acc. to<br />

EN 55 011<br />

Emission of radio<br />

interferences acc. to<br />

EN 55 011<br />

(limit class A)<br />

2/74<br />

Yes; The product is<br />

designed for use in<br />

industrial environments.<br />

When used in<br />

residential areas, the<br />

emission of radio interference<br />

according to<br />

limit class B of<br />

EN 55011 must be<br />

ensured. For further<br />

information refer to the<br />

user documentation<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Yes; The product is<br />

designed for use in<br />

industrial environments.<br />

When used in<br />

residential areas, the<br />

emission of radio interference<br />

according to<br />

limit class B of<br />

EN 55011 must be<br />

ensured. For further<br />

information refer to the<br />

user documentation<br />

Yes; The product is<br />

designed for use in<br />

industrial environments.<br />

When used in<br />

residential areas, the<br />

emission of radio interference<br />

according to<br />

limit class B of<br />

EN 55011 must be<br />

ensured. For further<br />

information refer to the<br />

user documentation<br />

Yes; The product is<br />

designed for use in<br />

industrial environments.<br />

When used in<br />

residential areas, the<br />

emission of radio interference<br />

according to<br />

limit class B of<br />

EN 55011 must be<br />

ensured. For further<br />

information refer to the<br />

user documentation<br />

Yes; The product is<br />

designed for use in<br />

industrial environments.<br />

When used in<br />

residential areas, the<br />

emission of radio interference<br />

according to<br />

limit class B of<br />

EN 55011 must be<br />

ensured. For further<br />

information refer to the<br />

user documentation<br />

Ambient conditions<br />

Operating temperature<br />

Operation<br />

Storage/transport<br />

temperature<br />

0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C<br />

Transport, storage<br />

Relative humidity<br />

-20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C<br />

max. relative humidity <strong>80</strong> % <strong>80</strong> % <strong>80</strong> % <strong>80</strong> % <strong>80</strong> %<br />

Drop height<br />

Degree and class of<br />

protection<br />

1.2 m 1.2 m 1.2 m 1.2 m 1.2 m<br />

IP65 housing<br />

Standards, approvals,<br />

certificates<br />

Yes Yes Yes Yes Yes<br />

Certifications CE, cULus, C-TICK CE, cULus, C-TICK CE, cULus, C-TICK CE, cULus, C-TICK CE, cULus, C-TICK<br />

TÜV safety certification Yes Yes Yes<br />

Safety Integrity Level to<br />

IEC 61508<br />

3 3 3<br />

Performance level acc.<br />

to EN ISO 13849-1<br />

E E E<br />

Safety category<br />

according to EN954-1<br />

6AV6 645-0DD01-<br />

0AX1<br />

6AV6 645-0DE01-<br />

0AX1<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV6 645-0EB01-<br />

0AX1<br />

Safety category<br />

according to EN954-1<br />

(enabling button,<br />

<strong>ST</strong>OP button if<br />

present) 4<br />

6AV6 645-0EC01-<br />

0AX1<br />

Safety category<br />

according to EN954-1<br />

(enabling button,<br />

<strong>ST</strong>OP button if<br />

present) 4<br />

6AV6 645-0EF01-<br />

0AX1<br />

Safety category<br />

according to EN954-1<br />

(enabling button,<br />

<strong>ST</strong>OP button if<br />

present) 4<br />

Operating systems<br />

Operating system<br />

Configuration<br />

Configuration software<br />

Windows CE Windows CE Windows CE Windows CE Windows CE<br />

Configuration tool see "Configuration overview" from page 2/3


■ Technical specifications (continued)<br />

6AV6 645-0DD01-<br />

0AX1<br />

Operator panels<br />

Mobile Panels — 270 series<br />

SIMATIC Mobile Panel 277(F) IWLAN<br />

Functionality under<br />

WinCC flexible/WinCC<br />

(TIA portal)<br />

Applications/options see chapter 4: HMI software/SIMATIC WinCC flexible options and SIMATIC WinCC (TIA portal) options<br />

Number of Visual Basic<br />

Scripts<br />

50 50 50 50 50<br />

Task planner Yes Yes Yes Yes Yes<br />

Help system Yes Yes Yes Yes Yes<br />

Status/control<br />

With alarm logging<br />

system (incl. buffer and<br />

acknowledgment)<br />

with SIMATIC S7 with SIMATIC S7 with SIMATIC S7 with SIMATIC S7 with SIMATIC S7<br />

Number of messages 4000 4 000 4000 4000 4000<br />

Bit messages Yes Yes Yes Yes Yes<br />

Analog messages Yes Yes Yes Yes Yes<br />

Message buffer Ring buffer (n x 512<br />

entries), retentive,<br />

maintenance-free<br />

Recipes<br />

6AV6 645-0DE01-<br />

0AX1<br />

Ring buffer (n x 512<br />

entries), retentive,<br />

maintenance-free<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV6 645-0EB01-<br />

0AX1<br />

Ring buffer (n x 512<br />

entries), retentive,<br />

maintenance-free<br />

6AV6 645-0EC01-<br />

0AX1<br />

Ring buffer (n x 512<br />

entries), retentive,<br />

maintenance-free<br />

6AV6 645-0EF01-<br />

0AX1<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Ring buffer (n x 512<br />

entries), retentive,<br />

maintenance-free<br />

Recipes 300 300 300 300 300<br />

Data records per<br />

recipe<br />

500 500 500 500 500<br />

Entries per data record 1000 1000 1000 1000 1000<br />

Recipe memory 64 KB integrated 64 KB integrated 64 KB integrated 64 KB integrated 64 KB integrated<br />

Number of process<br />

images<br />

Flash, expandable Flash, expandable Flash, expandable Flash, expandable Flash, expandable<br />

Process images 500 500 500 500 500<br />

Variables 2048 2 048 2048 2048 2048<br />

Limit values Yes Yes Yes Yes Yes<br />

Multiplexing<br />

Image elements<br />

Yes Yes Yes Yes Yes<br />

Text objects 10,000 text elements 10,000 text elements 10,000 text elements 10,000 text elements 10,000 text elements<br />

Graphic object Bit maps, icons, Bit maps, icons, Bit maps, icons, Bit maps, icons, Bit maps, icons,<br />

vector graphics vector graphics vector graphics vector graphics vector graphics<br />

dynamic objects Diagrams, bar graphs, Diagrams, bar graphs, Diagrams, bar graphs, Diagrams, bar graphs, Diagrams, bar graphs,<br />

sliders, analog sliders, analog sliders, analog sliders, analog sliders, analog<br />

display, invisible display, invisible display, invisible display, invisible display, invisible<br />

Lists<br />

buttons<br />

buttons<br />

buttons<br />

buttons<br />

buttons<br />

Text lists 500 500 500 500 500<br />

Graphic list 400 400 400 400 400<br />

Libraries<br />

Archiving<br />

Yes Yes Yes Yes Yes<br />

Number of archives<br />

per project<br />

20 20 20 20 20<br />

Number of measuring<br />

points per project<br />

20 20 20 20 20<br />

Number of entries per<br />

archive<br />

10 000 10 000 10 000 10 000 10 000<br />

Memory location<br />

Security<br />

Multi Media Card Multi Media Card Multi Media Card Multi Media Card Multi Media Card<br />

Number of user groups 50 50 50 50 50<br />

Passwords exportable Yes Yes Yes Yes Yes<br />

Number of user rights<br />

Data carrier support<br />

32 32 32 32 32<br />

Multimedia Card<br />

Recording<br />

Yes Yes Yes Yes Yes<br />

Recording/Printing Alarms, report (shift Alarms, report (shift Alarms, report (shift Alarms, report (shift Alarms, report (shift<br />

report), PROFINET report), PROFINET report), PROFINET report), PROFINET report), PROFINET<br />

2/75<br />

2


2<br />

Operator panels<br />

Mobile Panels — 270 series<br />

SIMATIC Mobile Panel 277(F) IWLAN<br />

■ Technical specifications (continued)<br />

Languages<br />

Configuration<br />

languages<br />

2/76<br />

D, GB, F, I, E, CHN<br />

"traditional", CHN<br />

"simplified", DK, FIN,<br />

GR, J, KP / ROK, NL,<br />

N, PL, P, RUS, S, CZ /<br />

SK, TR, H<br />

Character sets Tahoma, Arial, Courier<br />

New, WinCC flexible<br />

Standard, symbol<br />

languages, all freely<br />

scalable<br />

Transfer<br />

(upload/download)<br />

Transfer of configuration<br />

6AV6 645-0DD01-<br />

0AX1<br />

USB, Ethernet,<br />

automatic transfer<br />

recognition<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6AV6 645-0DE01-<br />

0AX1<br />

D, GB, F, I, E, CHN<br />

"traditional", CHN<br />

"simplified", DK, FIN,<br />

GR, J, KP / ROK, NL,<br />

N, PL, P, RUS, S, CZ /<br />

SK, TR, H<br />

Tahoma, Arial, Courier<br />

New, WinCC flexible<br />

Standard, symbol<br />

languages, all freely<br />

scalable<br />

USB, Ethernet,<br />

automatic transfer<br />

recognition<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV6 645-0EB01-<br />

0AX1<br />

D, GB, F, I, E, CHN<br />

"traditional", CHN<br />

"simplified", DK, FIN,<br />

GR, J, KP / ROK, NL,<br />

N, PL, P, RUS, S, CZ /<br />

SK, TR, H<br />

Tahoma, Arial, Courier<br />

New, WinCC flexible<br />

Standard, symbol<br />

languages, all freely<br />

scalable<br />

USB, Ethernet,<br />

automatic transfer<br />

recognition<br />

6AV6 645-0EC01-<br />

0AX1<br />

D, GB, F, I, E, CHN<br />

"traditional", CHN<br />

"simplified", DK, FIN,<br />

GR, J, KP / ROK, NL,<br />

N, PL, P, RUS, S, CZ /<br />

SK, TR, H<br />

Tahoma, Arial, Courier<br />

New, WinCC flexible<br />

Standard, symbol<br />

languages, all freely<br />

scalable<br />

USB, Ethernet,<br />

automatic transfer<br />

recognition<br />

6AV6 645-0EF01-<br />

0AX1<br />

D, GB, F, I, E, CHN<br />

"traditional", CHN<br />

"simplified", DK, FIN,<br />

GR, J, KP / ROK, NL,<br />

N, PL, P, RUS, S, CZ /<br />

SK, TR, H<br />

Tahoma, Arial, Courier<br />

New, WinCC flexible<br />

Standard, symbol<br />

languages, all freely<br />

scalable<br />

USB, Ethernet,<br />

automatic transfer<br />

recognition<br />

Wireless LAN<br />

Process coupling<br />

Yes Yes Yes Yes Yes<br />

Connection to<br />

controller<br />

see "System interfaces" from page 2/178<br />

Zones Yes Yes Yes Yes<br />

- Number of zones per<br />

project, max.<br />

254 254 254 254<br />

-Number of<br />

transponders for<br />

zones per project,<br />

max.<br />

255 255 255 255<br />

Effective range Yes Yes Yes<br />

- Number of effective<br />

ranges per project,<br />

max.<br />

127 127 127<br />

-Number of<br />

transponders for<br />

effective ranges per<br />

project, max.<br />

127 127<br />

Transponder Yes Yes Yes Yes<br />

-Number of<br />

transponders per<br />

project, max.<br />

256 256 256 256<br />

- Adjustable distance<br />

range<br />

Yes Yes Yes Yes<br />

- Adjustable distance,<br />

min.<br />

2m 2m 2m 2m<br />

- Adjustable distance,<br />

min.<br />

I/O<br />

8m 8m 8m 8m<br />

I/O devices<br />

Mechanics/material<br />

Barcode reader Barcode reader Barcode reader Barcode reader Barcode reader<br />

Type of housing (front)<br />

Dimensions and<br />

weight<br />

Dimensions<br />

Plastic Plastic Plastic Plastic Plastic<br />

Housing<br />

Dia 290 mm /<br />

Dia 290 mm /<br />

Dia 290 mm /<br />

Dia 290 mm /<br />

Dia 290 mm /<br />

diameter/depth (mm)<br />

Weight<br />

D 103 mm<br />

D 103 mm<br />

D 103 mm<br />

D 103 mm<br />

D 103 mm<br />

Weight 2.2 kg 2.2 kg 2.2 kg 2.2 kg 2.2 kg


■ Technical specifications (continued)<br />

6AV6 645-0FD01-<br />

0AX1<br />

6AV6 645-0FE01-<br />

0AX1<br />

6AV6 645-0GB01-<br />

0AX1<br />

Operator panels<br />

Mobile Panels — 270 series<br />

SIMATIC Mobile Panel 277(F) IWLAN<br />

6AV6 645-0GC01-<br />

0AX1<br />

6AV6 645-0GF01-<br />

0AX1<br />

Display<br />

Size 7.5" 7.5" 7.5" 7.5" 7.5"<br />

Display type<br />

Resolution (pixels)<br />

TFT, 65536 colors TFT, 65536 colors TFT, 65536 colors TFT, 65536 colors TFT, 65536 colors<br />

Resolution<br />

(WxH in pixel)<br />

Backlighting<br />

640 x 4<strong>80</strong> 640 x 4<strong>80</strong> 640 x 4<strong>80</strong> 640 x 4<strong>80</strong> 640 x 4<strong>80</strong><br />

MTBF backlighting<br />

(at 25 °C)<br />

Control elements<br />

about 50,000 hours about 50,000 hours about 50,000 hours about 50,000 hours about 50,000 hours<br />

Operating options Keys and Touch Keys and Touch Keys and Touch Keys and Touch Keys and Touch<br />

Function keys,<br />

programmable<br />

Connection for<br />

mouse/keyboard/barcod<br />

e reader<br />

18 function keys,<br />

18 with LEDs<br />

18 function keys,<br />

18 with LEDs<br />

18 function keys,<br />

18 with LEDs<br />

18 function keys,<br />

18 with LEDs<br />

18 function keys,<br />

18 with LEDs<br />

USB / USB / USB USB / USB / USB USB / USB / USB USB / USB / USB USB / USB / USB<br />

Keyboard<br />

Numeric/alphabetical<br />

input<br />

Touch operation<br />

Yes / Yes Yes / Yes Yes / Yes Yes / Yes Yes / Yes<br />

Touch screen<br />

Special operator<br />

controls<br />

analog, resistive analog, resistive analog, resistive analog, resistive analog, resistive<br />

Emergency stop<br />

2-channel, positive 2-channel, positive 2-channel, positive<br />

button<br />

latching<br />

latching<br />

latching<br />

Acknowledgement<br />

2-channel, number of 2-channel, number of 2-channel, number of<br />

button<br />

positions: 3<br />

positions: 3<br />

positions: 3<br />

Key-operated switch Yes, 3 switch settings Yes, 3 switch settings Yes, 3 switch settings<br />

Illuminated pushbutton Yes Yes Yes<br />

Handwheel<br />

Expansions for<br />

operator control of the<br />

process<br />

Yes Yes Yes<br />

DP direct LEDs (LEDs as<br />

S7 output I/O)<br />

F1...F18 F1...F18 F1...F18 F1...F18 F1...F18<br />

DP direct keys (screen<br />

buttons and keys as S7<br />

input I/O )<br />

F1...F18, Number of<br />

bytes for configurable<br />

buttons: 10<br />

F1...F18, Number of<br />

bytes for configurable<br />

buttons: 10<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

F1...F18, Number of<br />

bytes for configurable<br />

buttons: 10<br />

F1...F18, Number of<br />

bytes for configurable<br />

buttons: 10<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

F1...F18, Number of<br />

bytes for configurable<br />

buttons: 10<br />

Supply voltage<br />

Via charging station Yes Yes Yes Yes Yes<br />

Via table power supply<br />

Input voltage<br />

Yes Yes Yes Yes Yes<br />

Supply voltage<br />

Main battery<br />

DC DC DC DC DC<br />

Rated voltage 7.2 V 7.2 V 7.2 V 7.2 V 7.2 V<br />

Capacity 5100mA<strong>·</strong>h 5 100 mA<strong>·</strong>h 5100mA<strong>·</strong>h 5100mA<strong>·</strong>h 5100mA<strong>·</strong>h<br />

Number of loading<br />

cycles, min<br />

500 500 500 500 500<br />

Charging time, typ. 4h 4h 4h 4h 4h<br />

Operating time, typ. 4h 4h 4h 4h 4h<br />

Display for battery<br />

capacity<br />

Yes Yes Yes Yes Yes<br />

Energy-saving mode Yes Yes Yes Yes Yes<br />

Battery exchange in<br />

operation<br />

Yes Yes Yes Yes Yes<br />

2/77<br />

2


2<br />

Operator panels<br />

Mobile Panels — 270 series<br />

SIMATIC Mobile Panel 277(F) IWLAN<br />

■ Technical specifications (continued)<br />

Processor<br />

Processor<br />

Memory<br />

ARM, 520 MHz ARM, 520 MHz ARM, 520 MHz ARM, 520 MHz ARM, 520 MHz<br />

Type Flash / RAM Flash / RAM Flash / RAM Flash / RAM Flash / RAM<br />

Usable memory for user<br />

data<br />

2/78<br />

6 MB usable memory<br />

for user data<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6 MB usable memory<br />

for user data<br />

6 MB usable memory<br />

for user data<br />

6 MB usable memory<br />

for user data<br />

Type of output<br />

Status LEDs Yes Yes Yes Yes Yes<br />

LED for safe Yes Yes Yes<br />

LED for communication<br />

Yes Yes Yes Yes Yes<br />

LED for battery Yes Yes Yes Yes Yes<br />

Vibrations Yes Yes Yes Yes Yes<br />

Time of day<br />

Clock<br />

Type Hardware clock,<br />

battery backup,<br />

synchronizable<br />

Hardware clock,<br />

battery backup,<br />

synchronizable<br />

Hardware clock,<br />

battery backup,<br />

synchronizable<br />

Hardware clock,<br />

battery backup,<br />

synchronizable<br />

6 MB usable memory<br />

for user data<br />

Hardware clock,<br />

battery backup,<br />

synchronizable<br />

Interfaces<br />

Interfaces 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45)<br />

USB port 1 x USB 1 x USB 1 x USB 1 x USB 1 x USB<br />

Multi Media Card slot<br />

Industrial Ethernet<br />

1 MMC/SD card slot 1 MMC/SD card slot 1 MMC/SD card slot 1 MMC/SD card slot 1 MMC/SD card slot<br />

Industrial Ethernet<br />

interface<br />

1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45)<br />

Wireless LAN Yes Yes Yes Yes Yes<br />

Supports standards according to<br />

according to<br />

according to<br />

according to<br />

according to<br />

IEEE <strong>80</strong>2.11a<br />

IEEE <strong>80</strong>2.11a<br />

IEEE <strong>80</strong>2.11a<br />

IEEE <strong>80</strong>2.11a<br />

IEEE <strong>80</strong>2.11a<br />

Supported channels<br />

(according to<br />

IEEE <strong>80</strong>2.11a)<br />

Supported channels<br />

(according to<br />

IEEE <strong>80</strong>2.11b and<br />

IEEE <strong>80</strong>2.1g)<br />

Country approval<br />

(radio)<br />

6AV6 645-0FD01-<br />

0AX1<br />

Channel 34, channel<br />

36, channel 38,<br />

channel 40, channel<br />

42, channel 44,<br />

channel 46, channel<br />

48, channel 52,<br />

channel 56, channel<br />

60, channel 64,<br />

channel 149, channel<br />

153, channel 157,<br />

channel 161<br />

Channels 1 to 11,<br />

channel 12, channel<br />

13, channel 14<br />

6AV6 645-0FE01-<br />

0AX1<br />

Channel 34, channel<br />

36, channel 38,<br />

channel 40, channel<br />

42, channel 44,<br />

channel 46, channel<br />

48, channel 52,<br />

channel 56, channel<br />

60, channel 64,<br />

channel 149, channel<br />

153, channel 157,<br />

channel 161<br />

Channels 1 to 11,<br />

channel 12, channel<br />

13, channel 14<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV6 645-0GB01-<br />

0AX1<br />

Channel 34, channel<br />

36, channel 38,<br />

channel 40, channel<br />

42, channel 44,<br />

channel 46, channel<br />

48, channel 52,<br />

channel 56, channel<br />

60, channel 64,<br />

channel 149, channel<br />

153, channel 157,<br />

channel 161<br />

Channels 1 to 11,<br />

channel 12, channel<br />

13, channel 14<br />

6AV6 645-0GC01-<br />

0AX1<br />

Channel 34, channel<br />

36, channel 38,<br />

channel 40, channel<br />

42, channel 44,<br />

channel 46, channel<br />

48, channel 52,<br />

channel 56, channel<br />

60, channel 64,<br />

channel 149, channel<br />

153, channel 157,<br />

channel 161<br />

Channels 1 to 11,<br />

channel 12, channel<br />

13, channel 14<br />

6AV6 645-0GF01-<br />

0AX1<br />

Channel 34, channel<br />

36, channel 38,<br />

channel 40, channel<br />

42, channel 44,<br />

channel 46, channel<br />

48, channel 52,<br />

channel 56, channel<br />

60, channel 64,<br />

channel 149, channel<br />

153, channel 157,<br />

channel 161<br />

Channels 1 to 11,<br />

channel 12, channel<br />

13, channel 14<br />

USA, Canada USA, Canada USA, Canada USA, Canada USA, Canada<br />

Encryption WEP, WPA WEP, WPA WEP, WPA WEP, WPA WEP, WPA<br />

Supports rapid<br />

roaming<br />

Yes Yes Yes Yes Yes


■ Technical specifications (continued)<br />

Operator panels<br />

Mobile Panels — 270 series<br />

SIMATIC Mobile Panel 277(F) IWLAN<br />

Protocols<br />

PROFINET Yes Yes Yes Yes Yes<br />

PROFINET IO Yes Yes Yes Yes Yes<br />

PROFIsafe Yes Yes Yes<br />

EMC<br />

Emission of radio<br />

interference acc. to<br />

EN 55 011<br />

Emission of radio<br />

interferences acc. to<br />

EN 55 011<br />

(limit class A)<br />

Yes; The product is<br />

designed for use in<br />

industrial environments.<br />

When used in<br />

residential areas, the<br />

emission of radio interference<br />

according to<br />

limit class B of<br />

EN 55011 must be<br />

ensured. For further<br />

information refer to the<br />

user documentation<br />

Yes; The product is<br />

designed for use in<br />

industrial environments.<br />

When used in<br />

residential areas, the<br />

emission of radio interference<br />

according to<br />

limit class B of<br />

EN 55011 must be<br />

ensured. For further<br />

information refer to the<br />

user documentation<br />

Yes; The product is<br />

designed for use in<br />

industrial environments.<br />

When used in<br />

residential areas, the<br />

emission of radio interference<br />

according to<br />

limit class B of<br />

EN 55011 must be<br />

ensured. For further<br />

information refer to the<br />

user documentation<br />

Yes; The product is<br />

designed for use in<br />

industrial environments.<br />

When used in<br />

residential areas, the<br />

emission of radio interference<br />

according to<br />

limit class B of<br />

EN 55011 must be<br />

ensured. For further<br />

information refer to the<br />

user documentation<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Yes; The product is<br />

designed for use in<br />

industrial environments.<br />

When used in<br />

residential areas, the<br />

emission of radio interference<br />

according to<br />

limit class B of<br />

EN 55011 must be<br />

ensured. For further<br />

information refer to the<br />

user documentation<br />

Ambient conditions<br />

Operating temperature<br />

Operation<br />

Storage/transport<br />

temperature<br />

0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C<br />

Transport, storage<br />

Relative humidity<br />

-20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C<br />

max. relative humidity <strong>80</strong> % <strong>80</strong> % <strong>80</strong> % <strong>80</strong> % <strong>80</strong> %<br />

Drop height<br />

Degree and class of<br />

protection<br />

1.2 m 1.2 m 1.2 m 1.2 m 1.2 m<br />

IP65 housing<br />

Standards, approvals,<br />

certificates<br />

Yes Yes Yes Yes Yes<br />

Certifications CE, cULus, C-TICK CE, cULus, C-TICK CE, cULus, C-TICK CE, cULus, C-TICK CE, cULus, C-TICK<br />

TÜV safety certification Yes Yes Yes<br />

Safety Integrity Level to<br />

IEC 61508<br />

3 3 3<br />

Performance level acc.<br />

to EN ISO 13849-1<br />

E E E<br />

Safety category<br />

according to EN954-1<br />

6AV6 645-0FD01-<br />

0AX1<br />

6AV6 645-0FE01-<br />

0AX1<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV6 645-0GB01-<br />

0AX1<br />

Safety category<br />

according to EN954-1<br />

(enabling button,<br />

<strong>ST</strong>OP button if<br />

present) 4<br />

6AV6 645-0GC01-<br />

0AX1<br />

Safety category<br />

according to EN954-1<br />

(enabling button,<br />

<strong>ST</strong>OP button if<br />

present) 4<br />

6AV6 645-0GF01-<br />

0AX1<br />

Safety category<br />

according to EN954-1<br />

(enabling button,<br />

<strong>ST</strong>OP button if<br />

present) 4<br />

Operating systems<br />

Operating system<br />

Configuration<br />

Configuration software<br />

Windows CE Windows CE Windows CE Windows CE Windows CE<br />

Configuration tool see "Configuration overview" from page 2/3<br />

2/79<br />

2


2<br />

Operator panels<br />

Mobile Panels — 270 series<br />

SIMATIC Mobile Panel 277(F) IWLAN<br />

■ Technical specifications (continued)<br />

Functionality under<br />

WinCC flexible/WinCC<br />

(TIA Portal)<br />

Applications/options see chapter 4: HMI software/SIMATIC WinCC flexible options and SIMATIC WinCC (TIA portal) options<br />

Number of Visual Basic<br />

Scripts<br />

50 50 50 50 50<br />

Task planner Yes Yes Yes Yes Yes<br />

Help system Yes Yes Yes Yes Yes<br />

Status/control<br />

With alarm logging<br />

system (incl. buffer and<br />

acknowledgment)<br />

with SIMATIC S7 with SIMATIC S7 with SIMATIC S7 with SIMATIC S7 with SIMATIC S7<br />

Number of messages 4000 4 000 4000 4000 4000<br />

Bit messages Yes Yes Yes Yes Yes<br />

Analog messages Yes Yes Yes Yes Yes<br />

Message buffer Ring buffer (n x 512<br />

entries), retentive,<br />

maintenance-free<br />

Recipes<br />

2/<strong>80</strong><br />

6AV6 645-0FD01-<br />

0AX1<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6AV6 645-0FE01-<br />

0AX1<br />

Ring buffer (n x 512<br />

entries), retentive,<br />

maintenance-free<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV6 645-0GB01-<br />

0AX1<br />

Ring buffer (n x 512<br />

entries), retentive,<br />

maintenance-free<br />

6AV6 645-0GC01-<br />

0AX1<br />

Ring buffer (n x 512<br />

entries), retentive,<br />

maintenance-free<br />

6AV6 645-0GF01-<br />

0AX1<br />

Ring buffer (n x 512<br />

entries), retentive,<br />

maintenance-free<br />

Recipes 300 300 300 300 300<br />

Data records per<br />

recipe<br />

500 500 500 500 500<br />

Entries per data record 1000 1000 1000 1000 1000<br />

Recipe memory 64 KB integrated 64 KB integrated 64 KB integrated 64 KB integrated 64 KB integrated<br />

Number of process<br />

images<br />

Flash, expandable Flash, expandable Flash, expandable Flash, expandable Flash, expandable<br />

Process images 500 500 500 500 500<br />

Variables 2048 2 048 2048 2048 2048<br />

Limit values Yes Yes Yes Yes Yes<br />

Multiplexing<br />

Image elements<br />

Yes Yes Yes Yes Yes<br />

Text objects 10,000 text elements 10,000 text elements 10,000 text elements 10,000 text elements 10,000 text elements<br />

Graphic object Bit maps, icons, Bit maps, icons, Bit maps, icons, Bit maps, icons, Bit maps, icons,<br />

vector graphics vector graphics vector graphics vector graphics vector graphics<br />

dynamic objects Diagrams, bar graphs, Diagrams, bar graphs, Diagrams, bar graphs, Diagrams, bar graphs, Diagrams, bar graphs,<br />

sliders, analog sliders, analog sliders, analog sliders, analog sliders, analog<br />

display, invisible display, invisible display, invisible display, invisible display, invisible<br />

Lists<br />

buttons<br />

buttons<br />

buttons<br />

buttons<br />

buttons<br />

Text lists 500 500 500 500 500<br />

Graphic list 400 400 400 400 400<br />

Libraries<br />

Archiving<br />

Yes Yes Yes Yes Yes<br />

Number of archives<br />

per project<br />

20 20 20 20 20<br />

Number of measuring<br />

points per project<br />

20 20 20 20 20<br />

Number of entries per<br />

archive<br />

10 000 10 000 10 000 10 000 10 000<br />

Memory location<br />

Security<br />

Multi Media Card Multi Media Card Multi Media Card Multi Media Card Multi Media Card<br />

Number of user groups 50 50 50 50 50<br />

Passwords exportable Yes Yes Yes Yes Yes<br />

Number of user rights<br />

Data carrier support<br />

32 32 32 32 32<br />

Multimedia Card<br />

Recording<br />

Yes Yes Yes Yes Yes<br />

Recording/Printing Alarms, report (shift Alarms, report (shift Alarms, report (shift Alarms, report (shift Alarms, report (shift<br />

report), PROFINET report), PROFINET report), PROFINET report), PROFINET report), PROFINET


■ Technical specifications (continued)<br />

Languages<br />

Configuration<br />

languages<br />

D, GB, F, I, E, CHN<br />

"traditional", CHN<br />

"simplified", DK, FIN,<br />

GR, J, KP / ROK, NL,<br />

N, PL, P, RUS, S, CZ /<br />

SK, TR, H<br />

Character sets Tahoma, Arial, Courier<br />

New, WinCC flexible<br />

Standard, symbol<br />

languages, all freely<br />

scalable<br />

Transfer<br />

(upload/download)<br />

Transfer of configuration<br />

6AV6 645-0FD01-<br />

0AX1<br />

USB, Ethernet,<br />

automatic transfer<br />

recognition<br />

6AV6 645-0FE01-<br />

0AX1<br />

D, GB, F, I, E, CHN<br />

"traditional", CHN<br />

"simplified", DK, FIN,<br />

GR, J, KP / ROK, NL,<br />

N, PL, P, RUS, S, CZ /<br />

SK, TR, H<br />

Tahoma, Arial, Courier<br />

New, WinCC flexible<br />

Standard, symbol<br />

languages, all freely<br />

scalable<br />

USB, Ethernet,<br />

automatic transfer<br />

recognition<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV6 645-0GB01-<br />

0AX1<br />

D, GB, F, I, E, CHN<br />

"traditional", CHN<br />

"simplified", DK, FIN,<br />

GR, J, KP / ROK, NL,<br />

N, PL, P, RUS, S, CZ /<br />

SK, TR, H<br />

Tahoma, Arial, Courier<br />

New, WinCC flexible<br />

Standard, symbol<br />

languages, all freely<br />

scalable<br />

USB, Ethernet,<br />

automatic transfer<br />

recognition<br />

Operator panels<br />

Mobile Panels — 270 series<br />

SIMATIC Mobile Panel 277(F) IWLAN<br />

6AV6 645-0GC01-<br />

0AX1<br />

D, GB, F, I, E, CHN<br />

"traditional", CHN<br />

"simplified", DK, FIN,<br />

GR, J, KP / ROK, NL,<br />

N, PL, P, RUS, S, CZ /<br />

SK, TR, H<br />

Tahoma, Arial, Courier<br />

New, WinCC flexible<br />

Standard, symbol<br />

languages, all freely<br />

scalable<br />

USB, Ethernet,<br />

automatic transfer<br />

recognition<br />

6AV6 645-0GF01-<br />

0AX1<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

D, GB, F, I, E, CHN<br />

"traditional", CHN<br />

"simplified", DK, FIN,<br />

GR, J, KP / ROK, NL,<br />

N, PL, P, RUS, S, CZ /<br />

SK, TR, H<br />

Tahoma, Arial, Courier<br />

New, WinCC flexible<br />

Standard, symbol<br />

languages, all freely<br />

scalable<br />

USB, Ethernet,<br />

automatic transfer<br />

recognition<br />

Wireless LAN<br />

Process coupling<br />

Yes Yes Yes Yes Yes<br />

Connection to<br />

controller<br />

see "System interfaces" from page 2/178<br />

Zones Yes Yes Yes Yes<br />

- Number of zones per<br />

project, max.<br />

254 254 254 254<br />

-Number of<br />

transponders for<br />

zones per project,<br />

max.<br />

255 255 255 255<br />

Effective range Yes Yes Yes<br />

- Number of effective<br />

ranges per project,<br />

max.<br />

127 127 127<br />

-Number of<br />

transponders for<br />

effective ranges per<br />

project, max.<br />

127 127<br />

Transponder Yes Yes Yes Yes<br />

-Number of<br />

transponders per<br />

project, max.<br />

256 256 256 256<br />

- Adjustable distance<br />

range<br />

Yes Yes Yes Yes<br />

- Adjustable distance,<br />

min.<br />

2m 2m 2m 2m<br />

- Adjustable distance,<br />

min.<br />

I/O<br />

8m 8m 8m 8m<br />

I/O devices<br />

Mechanics/material<br />

Barcode reader Barcode reader Barcode reader Barcode reader Barcode reader<br />

Type of housing (front)<br />

Dimensions and<br />

weight<br />

Dimensions<br />

Plastic Plastic Plastic Plastic Plastic<br />

Housing<br />

Dia 290 mm /<br />

Dia 290 mm /<br />

Dia 290 mm /<br />

Dia 290 mm /<br />

Dia 290 mm /<br />

diameter/depth (mm)<br />

Weight<br />

D 103 mm<br />

D 103 mm<br />

D 103 mm<br />

D 103 mm<br />

D 103 mm<br />

Weight 2.2 kg 2.2 kg 2.2 kg 2.2 kg 2.2 kg<br />

2/81<br />

2


2<br />

Operator panels<br />

Mobile Panels — 270 series<br />

SIMATIC Mobile Panel 277(F) IWLAN<br />

■ Ordering data Order No. Order No.<br />

SIMATIC Mobile Panel 277<br />

Accessories<br />

IWLAN V2 (RoW version)<br />

Communication via WLAN<br />

(PROFINET)<br />

Communication via WLAN<br />

(PROFINET)<br />

with integrated handwheel,<br />

key-operated switch and two<br />

illuminated pushbuttons<br />

E<br />

E<br />

6AV6 645-0DD01-0AX1<br />

6AV6 645-0DE01-0AX1<br />

Note: Please order the table-top<br />

power supply or charging station<br />

as well. Required for charging the<br />

battery<br />

Table-top power supply incl. A<br />

power cable for EU, US, UK, JP<br />

(only suitable for operation<br />

under laboratory/office condi-<br />

6AV6 671-5CN00-0AX2<br />

SIMATIC Mobile Panel 277F<br />

tions)<br />

IWLAN V2 PROFIsafe<br />

Charger V2 for safe storage and A 6AV6 671-5CE00-0AX1<br />

(RoW version)<br />

charging of device incl. lock for<br />

Communication via WLAN<br />

(PROFINET)<br />

with acknowledgement button<br />

E 6AV6 645-0EB01-0AX1<br />

securing the device in the<br />

charger. Charging capabilities<br />

for up to two additional batteries<br />

and emergency stop button<br />

Additional battery with LED 6AV6 671-5CL00-0AX0<br />

Communication via WLAN<br />

(PROFINET)<br />

E 6AV6 645-0EC01-0AX1<br />

indicator for indicating the<br />

charge status<br />

with acknowledgement button<br />

Transponder V2 incl. batteries 6AV6 671-5CM00-0AX1<br />

and emergency stop button with<br />

(3x AA)<br />

integrated handwheel,<br />

key-operated switch, and two<br />

illuminated pushbuttons<br />

Transponder V1 incl. batteries<br />

(3x AA) (mandatory for<br />

operation in plants with Mobile<br />

6AV6 671-5CM00-0AX0<br />

RFID tag version: Communi- E 6AV6 645-0EF01-0AX1<br />

Panels 277(F) IWLAN V1)<br />

cation via WLAN (PROFINET)<br />

with acknowledgement button<br />

and emergency stop button with<br />

integrated handwheel,<br />

key-operated switch, and two<br />

illuminated pushbuttons<br />

Service pack V2 for Mobile A<br />

Panel 277(F) IWLAN V2 contains<br />

accessories pack for Mobile<br />

Panel 277 (labeling strip cover),<br />

battery compartment cover<br />

(device), cover left/right<br />

6AV6 671-5CA00-0AX2<br />

SIMATIC Mobile Panel 277<br />

IWLAN V2 (USA version)<br />

Communication via WLAN<br />

(PROFINET)<br />

Communication via WLAN<br />

(PROFINET)<br />

with integrated handwheel,<br />

key-operated switch and two<br />

illuminated pushbuttons<br />

E<br />

E<br />

6AV6 645-0FD01-0AX1<br />

6AV6 645-0FE01-0AX1<br />

(charger), power supply<br />

connector counterpart<br />

(charger), replacement key<br />

(charger)<br />

Service pack V1 for Mobile<br />

Panel 277(F) IWLAN V2 contains<br />

accessories pack for Mobile<br />

Panel 277 (labeling strip cover),<br />

battery compartment cover<br />

(device), cover left/right<br />

(charger), power supply<br />

connector counterpart<br />

(charger), replacement key<br />

(charger)<br />

6AV6 671-5CA00-0AX1<br />

SIMATIC Mobile Panel 277F<br />

IWLAN V2 PROFIsafe<br />

(USA version)<br />

with acknowledgement button<br />

and emergency stop button<br />

E 6AV6 645-0GB01-0AX1<br />

with acknowledgement button<br />

and emergency stop button with<br />

integrated handwheel,<br />

key-operated switch, and two<br />

illuminated pushbuttons<br />

E 6AV6 645-0GC01-0AX1<br />

with acknowledgement button<br />

and emergency stop button with<br />

integrated handwheel,<br />

key-operated switch, and two<br />

illuminated pushbuttons<br />

(tag version)<br />

E 6AV6 645-0GF01-0AX1<br />

Starter kit<br />

SIMATIC Mobile Panel 277(F)<br />

IWLAN (RoW version)<br />

for<br />

Mobile Panel 277 IWLAN V2 E 6AV6 651-5GA01-0AA1<br />

Mobile Panel 277F IWLAN V2 E 6AV6 651-5HA01-0AA1<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

2/82<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SCALANCE W-786 Access<br />

Points for SIMATIC Mobile<br />

Panel 277(F) IWLAN<br />

IWLAN Access Points with<br />

integrated radio interfaces;<br />

radio networks;<br />

IEEE <strong>80</strong>2.11b/g/a/h at 2.4/5 GHz<br />

up to 54 Mbit/s. National<br />

approvals; WPA2/AES; Power<br />

over Ethernet (PoE), degree of<br />

protection IP65<br />

(-40 °C to +70 °C); scope of<br />

delivery: Mounting hardware,<br />

48 V DC terminal block; manual<br />

on CD-ROM; German/English;


H: Subject to export regulations: AL: 9I999 and ECCN: EAR99H<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Mobile Panels — 270 series<br />

SIMATIC Mobile Panel 277(F) IWLAN<br />

■ Ordering data Order No. Order No.<br />

SCALANCE W-786-2RR<br />

PS791-2DC power supply 6GK5 791-2DC00-0AA0<br />

IWLAN Dual Access Point with<br />

two integrated radio interface for<br />

setting up radio links with i<strong>PC</strong>F;<br />

RJ45 connection<br />

24 V DC power supply for installation<br />

in SCALANCE W-786<br />

products; operating instructions<br />

in German/English<br />

Four internal antennas<br />

PS791-2AC power supply 6GK5 791-2AC00-0AA0<br />

National approvals for operation H<br />

outside the U.S.<br />

National approvals for operation H<br />

within the U.S.<br />

6GK5 786-2BA60-6AA0<br />

6GK5 786-2BA60-6AB0<br />

110 V AC to 230 V AC power<br />

supply for installation in<br />

SCALANCE W-786 products;<br />

operating instructions in<br />

German/English<br />

SCALANCE W-786-1PRO<br />

Other compatible accessories:<br />

IWLAN Access Points with built-in<br />

Wall mounting bracket for see HMI accessories<br />

wireless interface RJ45<br />

Mobile Panels<br />

connection<br />

Memory card multi-media see HMI accessories<br />

Two internal antennas<br />

card/SD card<br />

National approvals for operation H<br />

outside the U.S.<br />

National approvals for operation H<br />

within the U.S.<br />

Further IWLAN Access Point<br />

versions:<br />

6GK5 786-1BA60-2AA0<br />

6GK5 786-1BA60-2AB0<br />

Mobile Panel 277 cover<br />

membrane<br />

Key labeling strips for Mobile<br />

Panel 277<br />

Spare key for Mobile Panels<br />

Configuration<br />

see HMI accessories<br />

see HMI accessories<br />

see HMI accessories<br />

SCALANCE W-784 Access 6GK5 784-1AA30-...<br />

with SIMATIC WinCC flexible see HMI software<br />

Points<br />

Documentation<br />

IWLAN Access Points with<br />

(see <strong>Catalog</strong> IK PI)<br />

(to be ordered separately)<br />

integrated radio interfaces (see<br />

<strong>Catalog</strong> IK PI), radio networks<br />

IEEE <strong>80</strong>2.11b/g/a/h at 2.4/5 GHz<br />

up to 54 Mbit/s. National<br />

approvals; WPA2/AES; Power<br />

Mobile Panel 277F IWLAN V2<br />

Operating Instructions<br />

German<br />

English<br />

6AV6 691-1DQ01-2AA1<br />

6AV6 691-1DQ01-2AB1<br />

over Ethernet (PoE), degree of<br />

protection IP30<br />

(-20 °C to +60 °C); scope of<br />

delivery: Mounting hardware,<br />

French<br />

Italian<br />

Spanish<br />

6AV6 691-1DQ01-2AC1<br />

6AV6 691-1DQ01-2AD1<br />

6AV6 691-1DQ01-2AE1<br />

24 V DC terminal block; manual<br />

on CD-ROM; German/English;<br />

Mobile Panel 277 IWLAN V2<br />

Operating Instructions<br />

SCALANCE W-786 Access<br />

Points<br />

6GK5 786-...<br />

German<br />

English<br />

6AV6 691-1DM01-2AA1<br />

6AV6 691-1DM01-2AB1<br />

IWLAN Access Points with<br />

integrated radio interfaces (see<br />

(see <strong>Catalog</strong> IK PI)<br />

French<br />

Italian<br />

6AV6 691-1DM01-2AC1<br />

6AV6 691-1DM01-2AD1<br />

<strong>Catalog</strong> IK PI); radio networks<br />

Spanish 6AV6 691-1DM01-2AE1<br />

IEEE <strong>80</strong>2.11b/g/a/h at 2.4/5 GHz<br />

up to 54 Mbit/s. National<br />

approvals; WPA2/AES; Power<br />

over Ethernet (PoE), degree of<br />

User Manual WinCC flexible<br />

Compact/Standard/Advanced<br />

German 6AV6 691-1AB01-3AA0<br />

protection IP65<br />

English 6AV6 691-1AB01-3AB0<br />

(-40 °C to +70 °C); scope of<br />

delivery: Mounting hardware,<br />

48 V DC terminal block; manual<br />

on CD-ROM; German/English;<br />

French<br />

Italian<br />

Spanish<br />

6AV6 691-1AB01-3AC0<br />

6AV6 691-1AB01-3AD0<br />

6AV6 691-1AB01-3AE0<br />

SCALANCE W-788 Access<br />

Points<br />

IWLAN Access Points with<br />

integrated radio interfaces (see<br />

<strong>Catalog</strong> IK PI); radio networks<br />

IEEE <strong>80</strong>2.11b/g/a/h at 2.4/5 GHz<br />

6GK5 788-...<br />

(see <strong>Catalog</strong> IK PI)<br />

WinCC flexible Communication<br />

User Manual<br />

German<br />

English<br />

French<br />

Italian<br />

6AV6 691-1CA01-3AA0<br />

6AV6 691-1CA01-3AB0<br />

6AV6 691-1CA01-3AC0<br />

6AV6 691-1CA01-3AD0<br />

up to 54 Mbit/s. National<br />

Spanish 6AV6 691-1CA01-3AE0<br />

approvals; WPA2/AES; Power<br />

over Ethernet (PoE), degree of<br />

protection IP65<br />

(-20 °C to +60 °C); scope of<br />

delivery: 2 ANT795-4MR<br />

antennas, IP67 hybrid plug-in<br />

connector, mounting hardware,<br />

manual on CD-ROM,<br />

German/English<br />

Accessories see HMI accessories<br />

The function manuals "Fail-Safe Operation of the Mobile<br />

Panel 277F IWLAN V1" are available for downloading in English,<br />

German and Japanese.<br />

http://support.automation.siemens.com/WW/view/en/31255853<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/83<br />

2


2<br />

Operator panels<br />

Mobile Panels — 270 series<br />

SIMATIC Mobile Panel 277(F) IWLAN<br />

■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical specifications.<br />

Mobile Panel 277(F) IWLAN – Front and side view<br />

343<br />

Charger dimensional drawing<br />

2/84<br />

61 85<br />

9<br />

155 117<br />

ø 290 mm<br />

160<br />

208<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

198<br />

8°<br />

103 mm<br />

129 mm<br />

72<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00297<br />

G_<strong>ST</strong><strong>80</strong>_XX_00299<br />

45<br />

162<br />

172<br />

Transponder dimensional drawing<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-mobile-panels<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.<br />

38.5<br />

90<br />

G_<strong>ST</strong><strong>80</strong>_XX_00298


■ Overview<br />

The user-friendly text display for the S7-200<br />

For control and monitoring:<br />

Message text display, intervention in PLC program, setting of<br />

inputs and outputs<br />

Direct connection to CPU interface using supplied cable or<br />

incorporation into network (also via EM 277)<br />

No separate power supply required<br />

No separate parameterization software required<br />

Addressing and setting of contrast in supplied menu<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Micro Panels<br />

Text Display TD 200<br />

■ Application<br />

The TD 200 Text Display is the optimum solution for all operator<br />

control and monitoring tasks of SIMATIC S7-200.<br />

It supports:<br />

display of message texts<br />

interventions in the control program, e.g. modification of<br />

setpoints<br />

setting of inputs and outputs, e.g. for switching a motor on and<br />

off<br />

■ Design<br />

The TD 200 is simply connected to the PPI interface of the<br />

S7-200 using the supplied connecting cable. A separate power<br />

supply is not required. It is also possible to connect several<br />

TD 200 units to one S7-200.<br />

The TD 200 features:<br />

Rugged plastics housing with degree of protection IP65<br />

(front):<br />

Increased watertightness due to absence of slots for labeling<br />

strips<br />

Mounting depth 27 mm:<br />

The TD 200 can be mounted without additional accessories in<br />

control cabinets or operator panels, or used as a handheld<br />

unit<br />

Backlit LC display;<br />

readable even under unfavorable lighting<br />

Ergonomically designed input keys,<br />

below which are programmable function keys<br />

Integrated interface for connection of cable<br />

Connection for optional power supply:<br />

A power supply unit is required if the distance between the<br />

TD 200 and S7-200 is more than 2.5 m. PROFIBUS cables are<br />

then available instead of the connection cable<br />

Customized labeling strips:<br />

The back of the housing has to be removed to mount the<br />

labeling strips. This must therefore be performed before the<br />

unit is installed<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/85<br />

2


2<br />

Operator panels<br />

Micro Panels<br />

Text Display TD 200<br />

■ Function<br />

■ Technical specifications<br />

The TD 200 permits:<br />

6ES7 272-0AA30-0YA1<br />

Display of message texts:<br />

Product type designation Text Display TD 200<br />

Up to <strong>80</strong> message texts (alarms) with max. 6 variables display<br />

current operating states and can be optionally parameterized<br />

to require acknowledgment and can be additionally protected<br />

by a password. Also up to 64 static alarms with up to<br />

6 variables can be configured. System texts are stored in<br />

English, German, French, Spanish and Italian in the unit.<br />

Various character sets can be selected, and messages can<br />

be additionally saved in the simplified Chinese character set<br />

Operator control and monitoring<br />

Operating<br />

Number of lines<br />

Number of characters per line<br />

Character size<br />

Design of display<br />

2<br />

20; Characters/line: ASCII, cyrillic;<br />

10 characters/line: Chinese<br />

5mm<br />

LCD backlit<br />

Display and modification of process parameters:<br />

Input voltage<br />

Process parameters are output on the display, and can be<br />

modified using the input keys, e.g. for temperature settings or<br />

modifications to speed<br />

Setting of inputs and outputs:<br />

Rated value (DC) 24 V; Power supplied over the<br />

S7-200 communications interface<br />

or optional external power supply<br />

unit; the CPU sensor power<br />

supply (24 V DC) is not subjected<br />

A memory bit is assigned to each of the 8 programmable<br />

to load<br />

function keys. These can then be set during operation, e.g.<br />

during commissioning, testing and diagnostics. It is then<br />

possible e.g. to control motors without having to install<br />

additional control elements in the system<br />

Input current<br />

Rated value at 24 V DC<br />

Transmission speed (PPI), max.<br />

120 mA<br />

187.5 kbit/s<br />

Additional functions and features:<br />

E.g. processing of floating-point numbers, symbols for bar<br />

1st interface<br />

Physics RS 485<br />

graph display, various data blocks for operation of several Functionality<br />

TD 200 displays on one CPU, password protection for<br />

integrated SETUP menu and modified variables<br />

Activation of TD 200 editing mode by PLC:<br />

Variables embedded in messages can be edited directly<br />

without having to press the Enter key or to place the cursor at<br />

the variable<br />

Setting a PLC bit:<br />

PPI<br />

PPI<br />

Number of nodes, max.<br />

Operating temperature<br />

Min.<br />

max.<br />

Yes<br />

126; S7-200, OP, TP, TBP, PG/<strong>PC</strong><br />

0°C<br />

60 °C<br />

-Set bit:<br />

Storage/transport temperature<br />

When a function key is pressed, a bit is set in the PLC. This Min. -40 °C<br />

must be reset by the user program<br />

max. 70 °C<br />

- Momentary:<br />

A bit is set when pressing a function key, and deleted again<br />

when the key is released<br />

Degree and class of protection<br />

IP65 Yes; at front<br />

New character set (Greek, Latin2, Turkish) to support further<br />

foreign languages<br />

Dimensions and weight<br />

Dimensions<br />

Width 148 mm<br />

Programming<br />

Height 76 mm<br />

The configuration data of the TD 200 are saved in the CPU of the<br />

S7-200. The message text strings and configuration parameters<br />

are created with the <strong>ST</strong>EP 7 Micro/WIN configuration software of<br />

V4 and higher. Additional parameterization software is not<br />

Depth<br />

Mounting cutout, width<br />

Mounting cutout, height<br />

Cabinet/switchboard strength<br />

27 mm<br />

138 mm<br />

68 mm<br />

0.3 mm; 0.3 to 4 mm<br />

required.<br />

Weight<br />

Special data areas are reserved in the CPU of the S7-200 for<br />

data exchange with the TD 200. The TD 200 directly accesses<br />

the respectively required functions of the CPU via these data<br />

areas. A separate TD 200 wizard in <strong>ST</strong>EP 7 Micro/WIN V4 and<br />

higher supports user-friendly parameter assignment.<br />

Weight, approx. 250 g<br />

2/86<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Ordering data Order No. ■ Dimensional drawings<br />

Text Display TD 200 6ES7 272-0AA30-0YA1<br />

for connection to SIMATIC<br />

S7-200; can be used with<br />

<strong>ST</strong>EP 7-Micro/WIN V3.2 SP4 or<br />

higher, incl. connecting cable<br />

Connecting cables 6ES7 901-3EB10-0XA0<br />

For connecting TD 100C or<br />

TD 200C to S7-200<br />

Accessories see HMI Accessories<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

All specifications in mm.<br />

148<br />

TD200: Installation cutout (W x H) in mm: 138 x 68<br />

Operator panels<br />

Micro Panels<br />

Text Display TD 200<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-micropanels<br />

76<br />

28<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00320<br />

2/87<br />

2


2<br />

Operator panels<br />

Micro Panels<br />

Text Display TD 400C<br />

■ Overview<br />

More screen space and extremely good readability thanks to<br />

backlit four-line display<br />

Customizable operator interface with 15 tactile keys<br />

Acoustic and visual feedback from key operation<br />

Optimal support of the S7-200:<br />

- Direct connection to the S7-200 interface via supplied cable<br />

- No separate power supply required<br />

- Parameterization with <strong>ST</strong>EP 7-Micro/WIN V4 SP6<br />

2/88<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Application<br />

The TD 400C Text Display is the optimal solution for all operator<br />

control and monitoring tasks of the SIMATIC S7-200. The<br />

customizable operator interface enables optimal adaptation of<br />

the device to the surroundings in which it is used.<br />

It enables:<br />

Display of message texts<br />

Intervention in the control program, e.g. setpoint changes<br />

Setting of inputs and outputs, e.g. for switching a motor on<br />

and off<br />

Compatibility with the TD 100C, TD 200 and TD 200C Text<br />

Displays:<br />

The TD 400C Text Display is not compatible with existing Text<br />

Displays (different mounting dimensions, configuration cannot<br />

be adopted).<br />

■ Design<br />

The TD 400C is connected to the S7-200 using the supplied<br />

connecting cable. A separate power supply is not required. It is<br />

also possible to connect several TD 400Cs to one S7-200.<br />

The TD 400C has the following:<br />

3.7" <strong>ST</strong>N LCD backlit display:<br />

Up to 4 text lines can be configured<br />

Rugged plastic housing in degree of protection IP65 (on front),<br />

IP20 (on rear):<br />

Increased waterproofing because there are no slots for<br />

labeling strips<br />

Installation depth of 31 mm:<br />

The TD 400C can be installed in control cabinets or used as a<br />

handheld device without any other accessories<br />

Customizable operator interface:<br />

The design (colors, pictures, text, etc.) of the operator<br />

interface can be individually designed. Configuration is<br />

carried out with the Keypad Designer (component part of<br />

<strong>ST</strong>EP 7-Micro/WIN)<br />

Configuration of tactile keys:<br />

Up to 15 permanently positioned, tactile keys can be assigned<br />

numerous functions (e.g. direction keys, messages,<br />

Set PLC bit)<br />

Connection for optional power supply:<br />

A power supply is required at a distance of more than 2.5 m<br />

between the TD 400C and S7-200. PROFIBUS bus cables are<br />

then available in place of the supplied connecting cable


■ Function<br />

Display of message texts:<br />

Up to <strong>80</strong> message texts (alarms) with up to 6 variables display<br />

current operating states and can be optionally parameterized as<br />

requiring acknowledgement and additionally protected by a<br />

password. In addition, up to 64 static messages, also with up to<br />

6 variables, can be configured. Message texts can be displayed<br />

in two lines or four lines depending on the character size set.<br />

Four lines with 12 Chinese characters or 24 ASCII characters per<br />

line. Two lines with 8 Chinese characters or 16 ASCII characters<br />

per line.<br />

Display and modification of process parameters:<br />

Process parameters are shown on the display and can be<br />

modified using the input keys, e.g. for setting temperatures or<br />

changing speeds.<br />

Setting inputs and outputs:<br />

A memory bit is assigned to each of the programmable<br />

function keys. These bits can then be set during operation,<br />

e.g. at startup, and during test and diagnostics. In this way,<br />

motors can be controlled, for example, without having to install<br />

additional operator elements in the system.<br />

Additional functions and features:<br />

For example, processing of floating-point numbers, different<br />

data blocks for operating several TDs on one CPU, password<br />

protection for integrated SETUP menu, and modifiable<br />

variables.<br />

Activation of the TD 400C editing mode by the PLC:<br />

Variables embedded in messages can be edited direct<br />

without pressing the Enter key and moving the cursor to the<br />

variable.<br />

Setting a PLC bit:<br />

-Set bit:<br />

When a function key is pressed, a bit is set in the PLC. This<br />

must be reset again via the user program.<br />

- Momentary:<br />

When a function key is pressed, a bit is set, and when the key<br />

is released, the bit is deleted.<br />

New character set (Greek, Latin2, Turkish) for supporting<br />

further languages<br />

Programming of the S7-200 memory submodule<br />

Selecting the operating mode of the CPU (RUN/<strong>ST</strong>OP)<br />

Editing of the V memory area<br />

Programming<br />

The configuration data of the TD 400C is stored in the CPU of the<br />

S7-200. The message texts and the configuration parameters<br />

are created with the <strong>ST</strong>EP 7-Micro/WIN V4 SP6 programming<br />

software. Additional parameterization software is not required.<br />

The operating front design is configured with the Keypad<br />

Designer (component part of <strong>ST</strong>EP 7-Micro/WIN V4 SP6).<br />

Special data areas are reserved in the CPU of the S7-200 for<br />

data exchange with the TD 400C. The TD 400C accesses each<br />

of the required functions of the CPU direct via these data areas.<br />

User-friendly parameterization takes place via a dedicated<br />

TD 400 Wizard in <strong>ST</strong>EP 7-Micro/WIN V4 SP6.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Technical specifications<br />

Operator panels<br />

Micro Panels<br />

Text Display TD 400C<br />

6AV6 640-0AA00-0AX1<br />

Product type designation Text Display TD 400C<br />

Display<br />

Size 3.7"<br />

Display type <strong>ST</strong>N, black/white<br />

Resolution (pixels)<br />

Resolution (WxH in pixel) 192 x 64<br />

Backlighting<br />

MTBF backlighting (at 25 °C) about 20,000 hours<br />

Control elements<br />

Control elements Membrane keyboard<br />

Function keys, programmable 15 function keys<br />

Membrane keyboard Yes<br />

Supply voltage<br />

Input voltage<br />

permissible range DC<br />

Supply voltage 24 V DC<br />

Memory<br />

Usable memory for user data No info<br />

Interfaces<br />

Interfaces 1 x RS485 (max. 187.5 Mbit/s)<br />

Ambient conditions<br />

Operating temperature<br />

Operation 0 °C to +50 °C<br />

Storage/transport temperature<br />

Transport, storage -20 °C to +60 °C<br />

Degree and class of protection<br />

Front IP65, NEMA 4, NEMA 4x,<br />

NEMA 12 (when installed)<br />

Rear IP20<br />

Standards, approvals, certificates<br />

Certifications CE, FM Class I Div. 2, UL, C-TICK,<br />

NEMA 4, NEMA 4x, NEMA 12<br />

Configuration<br />

Configuration software<br />

Configuration tool see "Configuration overview"<br />

from page 2/3<br />

Functionality under WinCC<br />

flexible/WinCC (TIA Portal)<br />

Security<br />

Number of user groups 1<br />

Dimensions and weight<br />

Weight<br />

Weight 0.33 kg<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/89<br />

2


2<br />

Operator panels<br />

Micro Panels<br />

Text Display TD 400C<br />

■ Ordering data Order No. ■ Dimensional drawings<br />

TD 400C Text Display<br />

with customized operator<br />

interface on the device front;<br />

for connecting to<br />

SIMATIC S7-200; can be used<br />

from <strong>ST</strong>EP 7-Micro/WIN V4 SP6,<br />

incl. connecting cable<br />

A 6AV6 640-0AA00-0AX1<br />

Promotion package<br />

Consisting of:<br />

TD 400C<br />

SIMATIC S7-200<br />

SIMATIC <strong>ST</strong>EP 7 Micro/WIN V4.0<br />

Simulator module<br />

Memory module<br />

PPI cable<br />

CD-ROM with documentation<br />

TANOS Box<br />

B 6ES7 298-1AA20-0YA3<br />

Connecting cables<br />

for connecting TD 100C/TD 200C<br />

or TD 400C to S7-200<br />

6ES7 901-3EB10-0XA0<br />

Blank foils<br />

for printing customized keyboard<br />

layouts;<br />

2 perforated films per sheet;<br />

10 sheets per pack<br />

6AV6 671-0AP00-0AX0<br />

Accessories see HMI Accessories<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

2/90<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

All specifications in mm.<br />

174<br />

TD400C: Installation cutout (W x H) in mm: 163.5 x 93.5<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-micropanels<br />

102<br />

31<br />

G_<strong>ST</strong><strong>80</strong>_XX_00322


■ Overview<br />

Operator Panel for controlling and monitoring machines and<br />

systems<br />

Graphics in a new dimension: small and smart<br />

Pixel-graphics 3" LCD, monochrome<br />

8 system keys, 4 user-configurable function keys<br />

Specific to the SIMATIC S7-200:<br />

Communication with the controller takes place via the<br />

integrated interface (point-to-point)<br />

Connection to the controller via MPI or PROFIBUS DP cable<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Micro Panels<br />

SIMATIC OP 73micro<br />

■ Benefits<br />

High-contrast display for good readability<br />

Large keys for high operational safety<br />

Simple handling and configuring<br />

Fast configuring and start-up<br />

- Service-friendly thanks to maintenance-free design<br />

(no battery) and long service life of the backlighting<br />

Graphic library is available complete with ready-to-use<br />

display objects<br />

Can be used worldwide:<br />

- 32 languages can be configured (including Asiatic and<br />

Cyrillic character sets)<br />

- Up to 5 languages are selectable online<br />

■ Application<br />

OP 73micro Operator Panels can be used wherever machines<br />

and systems are controlled and monitored locally – in<br />

production, process and building automation alike. They are<br />

used in all types of sectors and applications.<br />

The OP 73micro has been designed specifically for use with the<br />

SIMATIC S7-200.<br />

Compatibility<br />

Same mounting cutout as for OP3 and TD 200<br />

■ Design<br />

3" LCD, 160 x 48 pixels, monochrome<br />

8 system keys, 4 freely configurable function keys<br />

Numeric and alphanumeric input using cursor control keys<br />

Compact design with small installation depth<br />

Rugged plastic housing<br />

The front is resistant to various oils, greases and standard<br />

detergents<br />

Plug-in terminals for connecting a 24 V DC power supply<br />

RS 485 interface for connecting the MPI connecting cable or<br />

the PPI adapter<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/91<br />

2


2<br />

Operator panels<br />

Micro Panels<br />

SIMATIC OP 73micro<br />

■ Function<br />

Input/output fields<br />

for displaying and changing process parameters<br />

Function keys<br />

for direct triggering of functions and actions. Up to<br />

16 functions can be configured simultaneously on function<br />

keys<br />

Graphics<br />

can be used as icons instead of text to "label" function keys or<br />

buttons. They can also be used as simple on-screen graphics.<br />

In the configuration tool, a library is available containing an<br />

extensive range of graphics and a wide variety of objects. All<br />

editors with an OLE interface can be used as graphic editors<br />

(such as PaintShop, Designer or CorelDraw)<br />

Fixed texts<br />

for labeling function keys, process images and process<br />

values in different font sizes<br />

Bars<br />

for the graphical display of dynamic values.<br />

Language selection during runtime<br />

- 5 online languages, 32 configuration languages incl. Asian<br />

and Cyrillic character sets<br />

User administration (security) according to the requirements<br />

of the various sectors<br />

- Authentication using password<br />

Signaling system<br />

- Discrete alarms<br />

- Analog messages<br />

- Freely definable message classes (e.g., status/fault<br />

messages) for definition of acknowledgment response and<br />

display of message events<br />

- Message history<br />

Help texts<br />

for process images, messages and variables<br />

Arithmetic functions<br />

Limit value monitoring<br />

for reliable process control of inputs and outputs<br />

Indicator light<br />

for machine and plant status indication<br />

Scheduler for global function execution<br />

Template concept<br />

Creation of picture templates (picture elements configured in<br />

the template appear in every image)<br />

User-friendly maintenance and configuration thanks to:<br />

- Backup and restoration of configuration, operating system<br />

and firmware on a <strong>PC</strong> using ProSave<br />

- Configuration download serially via RS485<br />

- Individual contrast settings<br />

- No batteries are necessary<br />

Configuring<br />

SIMATIC WinCC flexible Micro, Compact, Standard or<br />

Advanced engineering software Version 2004 SP1 and higher<br />

plus HSP is used for configuration.<br />

For more information about engineering software, see<br />

HMI software/engineering software SIMATIC WinCC flexible.<br />

A <strong>PC</strong>/PPI adapter cable is needed to download the configuration.<br />

■ Integration<br />

The OP 73micro can be connected to all SIMATIC S7-200 CPUs<br />

using the standard MPI bus cables or PROFIBUS DP cables<br />

(integration into networks possible).<br />

Note:<br />

For further information see "System interfaces"<br />

2/92<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Technical specifications<br />

6AV6 640-0BA11-0AX0<br />

Product type designation OP 73micro<br />

Display<br />

Size 3"<br />

Display type <strong>ST</strong>N, black/white<br />

Resolution (pixels)<br />

Resolution (WxH in pixel) 160 x 48<br />

Backlighting<br />

MTBF backlighting (at 25 °C) about 100,000 hours<br />

Control elements<br />

Control elements Membrane keyboard<br />

Function keys, programmable 4 function keys<br />

Connection for<br />

- / - / -<br />

mouse/keyboard/barcode reader<br />

Keyboard<br />

System keys 8<br />

Numeric/alphabetical input Yes / Yes<br />

Touch operation<br />

Touch screen No<br />

Supply voltage<br />

Input voltage<br />

permissible range +20.4 V to +28.8 V DC<br />

Supply voltage 24 V DC<br />

Input current<br />

Rated current 0.1 A<br />

Processor<br />

Processor ARM<br />

Memory<br />

Type Flash<br />

Usable memory for user data 128 KB usable memory for user<br />

data<br />

Time of day<br />

Clock<br />

Type Software clock, no battery<br />

backup<br />

Ambient conditions<br />

Operating temperature<br />

Operation (vertical installation) 0 °C to +50 °C<br />

Operation (max. tilt angle) 0 °C to +40 °C<br />

Storage/transport temperature<br />

Transport, storage -20 °C to +60 °C<br />

Relative humidity<br />

max. relative humidity 90 %<br />

Mounting position vertical<br />

maximum permissible angle of +/- <strong>80</strong> °<br />

inclination without external ventilation<br />

Degree and class of protection<br />

Front IP65, NEMA 4x, (when installed)<br />

Rear IP20<br />

Standards, approvals, certificates<br />

Certifications CE, GL, ABS, BV, DNV, LRS, UL,<br />

CSA, cULus, C-TICK, NEMA 4x<br />

Operating systems<br />

Operating system LINUX<br />

Configuration<br />

Configuration software<br />

Configuration tool see "Configuration overview" from<br />

page 2/3


Mounting cutout/device depth (W<br />

x H<br />

Weight<br />

Weight 0.25 kg<br />

138 mm x 68 mm / 28.5 mm<br />

device depth<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Micro Panels<br />

SIMATIC OP 73micro<br />

■ Technical specifications (continued)<br />

■ Ordering data Order No.<br />

6AV6 640-0BA11-0AX0<br />

SIMATIC OP 73micro 6AV6 640-0BA11-0AX0<br />

Product type designation OP 73micro<br />

Operator panel for connection to<br />

Functionality under WinCC<br />

flexible/WinCC (TIA Portal)<br />

Task planner Yes<br />

the SIMATIC S7-200, with<br />

3" display, monochrome incl.<br />

mounting accessories<br />

Help system Yes<br />

Configuration<br />

Status/control Not possible<br />

with SIMATIC WinCC flexible<br />

With alarm logging system<br />

(incl. buffer and acknowledgment)<br />

Documentation<br />

(to be ordered separately)<br />

Number of messages<br />

Bit messages<br />

Analog messages<br />

Message buffer<br />

Number of process images<br />

Process images<br />

Variables<br />

Limit values<br />

Multiplexing<br />

Image elements<br />

Text objects<br />

Graphic object<br />

dynamic objects<br />

250<br />

Yes<br />

Yes<br />

Ring buffer (n x 100 entries)<br />

250<br />

500<br />

Yes<br />

Yes<br />

1,000 text elements<br />

Bit maps, icons, icon (full-screen)<br />

Bar graphs<br />

Operating Instructions<br />

OP 73micro/TP 177micro<br />

German<br />

English<br />

French<br />

Italian<br />

Spanish<br />

User Manual<br />

WinCC flexible Micro<br />

German<br />

English<br />

French<br />

Italian<br />

Spanish<br />

6AV6 691-1DF01-0AA0<br />

6AV6 691-1DF01-0AB0<br />

6AV6 691-1DF01-0AC0<br />

6AV6 691-1DF01-0AD0<br />

6AV6 691-1DF01-0AE0<br />

6AV6 691-1AA01-3AA0<br />

6AV6 691-1AA01-3AB0<br />

6AV6 691-1AA01-3AC0<br />

6AV6 691-1AA01-3AD0<br />

6AV6 691-1AA01-3AE0<br />

Lists<br />

Text lists<br />

Graphic list<br />

Libraries<br />

Security<br />

150<br />

0<br />

Yes<br />

SIMATIC HMI Manual Collection B<br />

Electronic documentation,<br />

on DVD<br />

5 languages (English, French,<br />

German, Italian and Spanish);<br />

6AV6 691-1SA01-0AX0<br />

Number of user groups 1<br />

contains: all currently available<br />

Passwords exportable<br />

Number of users<br />

Yes<br />

1<br />

user manuals, manuals and<br />

communication manuals for<br />

SIMATIC HMI<br />

Data carrier support<br />

Multimedia Card<br />

Recording<br />

No<br />

Accessories see HMI Accessories<br />

Printer driver<br />

Fonts<br />

-<br />

Keyboard fonts<br />

Languages<br />

US American (English)<br />

Configuration languages D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified", DK, FIN, GR, J,<br />

KP / ROK, NL, N, PL, P, RUS, S,<br />

CZ / SK, TR, H<br />

Character sets<br />

Transfer (upload/download)<br />

WinCC flexible Standard,<br />

symbol languages<br />

Transfer of configuration<br />

Process coupling<br />

serial<br />

Connection to controller<br />

Expandability/openness<br />

see "System interface" from<br />

page 2/178<br />

Open Platform Program<br />

Dimensions and weight<br />

Dimensions<br />

No<br />

Front of enclosure (W x H) 154 mm x 84 mm<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/93<br />

2


2<br />

Operator panels<br />

Micro Panels<br />

SIMATIC OP 73micro<br />

■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical<br />

specifications.<br />

OP 73micro<br />

2/94<br />

154<br />

84<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

67.7<br />

28.5<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00144<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-micropanels<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.


■ Overview<br />

Touch Panel for operator control and monitoring of small<br />

machines and plants<br />

Low-cost entry-level product in the category of touch panels<br />

with graphic capability and all the basic functions required for<br />

simple tasks<br />

Pixel graphics 5.7" <strong>ST</strong>N touch screen (analog/resistive),<br />

Blue mode (4 levels)<br />

Specially for SIMATIC S7-200:<br />

Communication to the PLC through the integrated interface<br />

over a point-to-point link<br />

Connection to the PLC over MPI or PROFIBUS DP cable<br />

SIMATIC TP 177micro is the innovative successor to the<br />

Touch Panels SIMATIC TP 070/TP 170micro<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Micro Panels<br />

SIMATIC TP 177micro<br />

■ Benefits<br />

Can even be used where installation space is restricted<br />

thanks to vertical installation<br />

Fast configuring and start-up<br />

Service-friendly thanks to maintenance-free design and the<br />

long service life of the backlighting<br />

Graphic library is available completely with ready-to-use<br />

display objects<br />

Can be used worldwide:<br />

- 32 languages can be configured (including Asiatic and<br />

Cyrillic character sets)<br />

- Up to 5 languages are selectable online<br />

■ Application<br />

TP 177micro Touch Panels can be used wherever small<br />

machines and systems are controlled and monitored locally – in<br />

production, process and building automation alike. They are<br />

used in all types of sectors and applications.<br />

The TP 177micro has been designed specifically for use with the<br />

SIMATIC S7-200. With fast response times, it is also ideal for jog<br />

mode.<br />

Compatibility with TP 070/TP 170micro<br />

Same mounting cutout as the TP 070/TP 170micro<br />

■ Design<br />

5.7” <strong>ST</strong>N display, CCFL 1) backlit, Blue mode (4 levels)<br />

Resistive analog Touch<br />

Compact design with small installation depth<br />

Rugged plastic housing<br />

The front is resistant to various oils, greases and standard<br />

detergents<br />

Numeric system keyboard for decimal, binary and<br />

hexadecimal number formats<br />

On-screen alphanumeric keyboard<br />

Plug-in terminals for connecting a 24 V DC power supply<br />

RS 485 interface for connection of the MPI cable or the<br />

PPI adaptor<br />

1) Cold Cathode Fluorescence Lamps<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/95<br />

2


2<br />

Operator panels<br />

Micro Panels<br />

SIMATIC TP 177micro<br />

■ Function<br />

■ Integration<br />

Input/output fields<br />

for displaying and changing process parameters<br />

The TP 177micro can be connected to all SIMATIC S7-200-CPUs<br />

using the standard MPI bus cables or PROFIBUS DP cables<br />

Buttons<br />

(integration into networks possible).<br />

for direct triggering of functions and actions. Up to<br />

16 functions can be configured simultaneously on buttons<br />

Note:<br />

Graphics<br />

For further information see "System interfaces"<br />

can be used as icons instead of text to "label" function keys or<br />

buttons. They can also be used as background displays ■ Technical specifications<br />

(wallpaper).<br />

In the configuration tool, a library is available containing<br />

extensive graphics and a wide variety of objects. All editors Product type designation<br />

6AV6 640-0CA11-0AX1<br />

TP 177micro<br />

with an OLE interface can be used as graphics editors<br />

(such as PaintShop, Designer or CorelDraw).<br />

Display<br />

Size 5.7"<br />

Vector graphics<br />

Simple geometric basic forms (line, circle and rectangle) can<br />

be created direct in the configuring tool<br />

Fixed texts<br />

Display type<br />

Resolution (pixels)<br />

Resolution (WxH in pixel)<br />

<strong>ST</strong>N, 4 shades of blue<br />

320 x 240<br />

for labeling function keys, process images and process Backlighting<br />

values in any character size<br />

MTBF backlighting (at 25 °C) about 50,000 hours<br />

Bars<br />

Control elements<br />

for the graphical display of dynamic values<br />

Control elements Touch screen<br />

Changing languages<br />

- 5 online languages, 32 configuration languages incl. Asian<br />

and Cyrillic character sets<br />

User administration (security)<br />

- Authentication using password<br />

Signaling system<br />

- Discrete alarms<br />

Function keys, programmable<br />

Keyboard<br />

System keys<br />

Numeric/alphabetical input<br />

Touch operation<br />

Touch screen<br />

None<br />

0<br />

Yes / Yes<br />

analog, resistive<br />

- Analog messages<br />

Supply voltage<br />

- Freely definable message classes (e.g., status/fault<br />

Input voltage<br />

messages) for definition of acknowledgment response and permissible range +20.4 V to +28.8 V DC<br />

display of message events<br />

- Message history<br />

Help texts<br />

for process images, messages and variables<br />

Arithmetic functions<br />

Limit value monitoring<br />

for reliable process control of inputs and outputs<br />

Indicator light<br />

for machine and plant status indication<br />

Template concept<br />

Creation of picture templates (picture elements configured in<br />

the template appear in every image)<br />

User-friendly maintenance and configuration thanks to:<br />

- Backup and restoration of configuration, operating system<br />

and firmware on a <strong>PC</strong> using ProSave<br />

- Configuration download serially via RS485<br />

Supply voltage<br />

Input current<br />

Rated current<br />

Processor<br />

Processor<br />

Memory<br />

Type<br />

Usable memory for user data<br />

Time of day<br />

Clock<br />

Type<br />

Ambient conditions<br />

Operating temperature<br />

24 V DC<br />

0.24 A<br />

ARM<br />

Flash<br />

256 KB usable memory for user<br />

data<br />

Software clock, no battery<br />

backup<br />

- Individual contrast setting and calibration<br />

Operation (vertical installation) 0 °C to +50 °C<br />

- Clean screen<br />

Operation (max. tilt angle) 0 °C to +40 °C<br />

- No batteries are necessary<br />

Storage/transport temperature<br />

Configuring<br />

Transport, storage -20 °C to +60 °C<br />

SIMATIC WinCC flexible Micro, Compact, Standard or<br />

Advanced engineering software Version 2004 SP1 and higher<br />

Relative humidity<br />

max. relative humidity 90 %<br />

plus HSP is used for configuration.<br />

Mounting position vertical<br />

For more information about engineering software, see<br />

maximum permissible angle of incli- +/- 35 °<br />

HMI software/engineering software SIMATIC WinCC flexible.<br />

A <strong>PC</strong>/PPI adapter cable is needed to download the configuration.nation<br />

without external ventilation<br />

2/96<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Technical specifications (continued)<br />

6AV6 640-0CA11-0AX1<br />

Product type designation TP 177micro<br />

Degree and class of protection<br />

Front IP65, NEMA 4x, (when installed)<br />

Rear IP20<br />

Standards, approvals, certificates<br />

Certifications CE, GL, ABS, BV, DNV, LRS, FM<br />

Class I Div. 2, UL, CSA, cULus,<br />

EX-Zone 2 (in Vorbereitung),<br />

EX-Zone 22 (in Vorbereitung),<br />

C-TICK, NEMA 4x<br />

Operating systems<br />

Operating system LINUX<br />

Configuration<br />

Configuration software<br />

Configuration tool see "Configuration overview" from<br />

page 2/3<br />

Functionality under WinCC<br />

flexible/WinCC (TIA Portal)<br />

Task planner Yes<br />

Help system Yes<br />

Status/control Not possible<br />

With alarm logging system<br />

(incl. buffer and acknowledgment)<br />

Number of messages 500<br />

Bit messages Yes<br />

Analog messages Yes<br />

Message buffer Ring buffer (n x 128 entries)<br />

Number of process images<br />

Process images 250<br />

Variables 250<br />

Limit values Yes<br />

Multiplexing Yes<br />

Image elements<br />

Text objects 500 text elements<br />

Graphic object Bit maps, icons, icon (full-screen),<br />

vector graphics<br />

dynamic objects Diagrams, bar graphs<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Micro Panels<br />

SIMATIC TP 177micro<br />

6AV6 640-0CA11-0AX1<br />

Product type designation TP 177micro<br />

Lists<br />

Text lists 150<br />

Graphic list 100<br />

Libraries Yes<br />

Security<br />

Number of user groups 1<br />

Passwords exportable Yes<br />

Number of users 1<br />

Data carrier support<br />

Multimedia Card No<br />

Recording<br />

Printer driver -<br />

Fonts<br />

Keyboard fonts US American (English)<br />

Languages<br />

Configuration languages D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified", DK, FIN, GR, J,<br />

KP / ROK, NL, N, PL, P, RUS, S,<br />

CZ / SK, TR, H<br />

Character sets WinCC flexible Standard, symbol<br />

languages<br />

Transfer (upload/download)<br />

Transfer of configuration serial<br />

Process coupling<br />

Connection to controller see "System interfaces" from<br />

page 2/178<br />

Expandability/openness<br />

Open Platform Program No<br />

Dimensions and weight<br />

Dimensions<br />

Front of enclosure (W x H) 212 mm x 156 mm<br />

Mounting cutout/device depth<br />

(W x H)<br />

Weight<br />

Weight 0.75 kg<br />

198 mm x 142 mm / 45 mm<br />

device depth<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/97<br />

2


2<br />

Operator panels<br />

Micro Panels<br />

SIMATIC TP 177micro<br />

■ Ordering data Order No. ■ Dimensional drawings<br />

SIMATIC TP 177micro<br />

Touch Panel for connection to the<br />

SIMATIC S7-200, 5.7" <strong>ST</strong>N display<br />

Configuration<br />

with SIMATIC WinCC flexible<br />

Documentation<br />

(to be ordered separately)<br />

Operating Instructions<br />

OP 73micro, TP 177micro<br />

A 6AV6 640-0CA11-0AX1<br />

German 6AV6 691-1DF01-0AA0<br />

English 6AV6 691-1DF01-0AB0<br />

French 6AV6 691-1DF01-0AC0<br />

Italian 6AV6 691-1DF01-0AD0<br />

Spanish<br />

WinCC flexible Micro<br />

User Manual<br />

6AV6 691-1DF01-0AE0<br />

German 6AV6 691-1AA01-3AA0<br />

English 6AV6 691-1AA01-3AB0<br />

French 6AV6 691-1AA01-3AC0<br />

Italian 6AV6 691-1AA01-3AD0<br />

Spanish 6AV6 691-1AA01-3AE0<br />

SIMATIC HMI Manual Collection B<br />

Electronic documentation, on<br />

DVD<br />

5 languages (English, French,<br />

German, Italian, Spanish);<br />

contains: all currently available<br />

user manuals, manuals and<br />

communication manuals for<br />

SIMATIC HMI<br />

6AV6 691-1SA01-0AX0<br />

Accessories see HMI Accessories<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

2/98<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

All specifications in mm. Panel cutout see technical<br />

specifications.<br />

TP 177micro<br />

212<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-micropanels<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.<br />

156<br />

140<br />

44<br />

6.2<br />

G_<strong>ST</strong><strong>80</strong>_XX_00143


■ Overview<br />

The user-friendly text display for the S7-200<br />

For operation and monitoring:<br />

display of message texts, interventions in the control program,<br />

setting of inputs and outputs<br />

Direct connection to CPU interface via included cable, or<br />

integration into network (also via EM 277)<br />

No separate power supply required<br />

No separate configuration software required<br />

Addressing and contrast adjustment via provided menu<br />

Note:<br />

SIPLUS extreme products are based on <strong>Siemens</strong> Industry<br />

standard products. The contents listed here were taken from the<br />

respective standard products. SIPLUS extreme-specific information<br />

was added.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

SIPLUS Micro Panels<br />

SIPLUS S7-200 TD 200<br />

SIPLUS S7-200 TD 200<br />

Order number 6AG1 272-0AA30-2YA1<br />

Order No. based on 6ES7 272-0AA30-0YA1<br />

Ambient temperature range -25 ... +60 °C<br />

Conformal coating Coating of the printed circuit<br />

boards and the electronic components<br />

Technical data The technical data of the<br />

standard product applies except<br />

for the ambient conditions.<br />

Ambient conditions<br />

Relative humidity 5 ... 100 %<br />

Condensation permissible<br />

Biologically active substances Conformity with EN 60721-3-3,<br />

Class 3B2 mold and fungal<br />

spores (except fauna)<br />

Chemically active substances Conformity with EN 60721-3-3,<br />

Class 3C4 incl. salt mist and<br />

ISA–S71. 04 severity level G1; G2;<br />

1) 2)<br />

G3; GX<br />

Mechanically active substances Conformity with EN 60721-3-3,<br />

Class 3S4 including conductive<br />

sand, dust 2)<br />

Air pressure (depending on the 10<strong>80</strong> ... 795 hPa<br />

highest positive temperature range (-1000 ... +2000 m)<br />

specified)<br />

see ambient temperature range<br />

795 ... 658 hPa<br />

(+2000 ... +3500 m)<br />

derating 10 K<br />

658 ... 540 hPa<br />

(+3500 ... +5000 m)<br />

derating 20 K<br />

1) ISA-S71.04 severity level GX: Long-term load: SO2 < 4.8 ppm;<br />

H2S


2<br />

Operator panels<br />

SIPLUS Micro Panels<br />

SIPLUS S7-200 TD 400C<br />

■ Overview<br />

Additional screen space and high readability via backlit<br />

four-line display<br />

Customizable user interface with 15 tactile keys<br />

Audible and visual feedback upon pressing of key<br />

Optimal support of the S7-200:<br />

- Direct connection to the S7-200 interface via included cable<br />

- No separate power supply required<br />

- Configuration with <strong>ST</strong>EP 7 Micro / WIN V4 SP6<br />

Note:<br />

SIPLUS extreme products are based on <strong>Siemens</strong> Industry<br />

standard products. The contents listed here were taken from the<br />

respective standard products. SIPLUS extreme-specific information<br />

was added.<br />

2/100<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIPLUS S7-200 TD 400C<br />

Order number 6AG1 640-0AA00-2AX1<br />

Order No. based on 6AV6 640-0AA00-0AX1<br />

Ambient temperature range -10 ... + 60 °C<br />

Conformal coating Coating of the printed circuit<br />

boards and the electronic<br />

components<br />

Technical data The technical data of the<br />

standard product applies except<br />

for the ambient conditions.<br />

Ambient conditions<br />

Relative humidity 5 ... 100 %<br />

Condensation permissible<br />

Biologically active substances Conformity with EN 60721-3-3,<br />

Class 3B2 mold and fungal<br />

spores (except fauna)<br />

Chemically active substances Conformity with EN 60721-3-3,<br />

Class 3C4 incl. salt mist and<br />

ISA–S71.04 severity level G1; G2;<br />

1) 2)<br />

G3; GX<br />

Mechanically active substances Conformity with EN 60721-3-3,<br />

Class 3S4 including conductive<br />

sand, dust 2)<br />

Air pressure (depending on the 10<strong>80</strong> ... 795 hPa<br />

highest positive temperature range (-1000 ... +2000 m)<br />

specified)<br />

see ambient temperature range<br />

795 ... 658 hPa<br />

(+2000 ... +3500 m)<br />

derating 10 K<br />

658 ... 540 hPa<br />

(+3500 ... +5000 m)<br />

derating 20 K<br />

1) ISA-S71.04 severity level GX: Long-term load:<br />

SO2


■ Overview<br />

Operator Panel for operator control and monitoring functions<br />

of machines and plants<br />

Graphics in a new dimension: Small and smart<br />

Full graphics 3" LCD, monochrome<br />

8 system keys, 4 freely programmable function keys<br />

All interfaces are on-board (e.g. MPI, PROFIBUS DP)<br />

SIMATIC OP 73 is the successor to the OP3 operator panel<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Panels — 70 series<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC OP 73<br />

■ Benefits<br />

High-contrast display for good readability<br />

Large keys for high operational safety<br />

Simple handling and configuring<br />

Integral component of Totally Integrated Automation (TIA):<br />

Increases productivity, minimizes the engineering outlay,<br />

reduces lifecycle costs<br />

Service-friendly through maintenance-free design (no battery)<br />

and high service life of the backlighting<br />

Graphic library is available completely with ready-to-use<br />

display objects<br />

Can be used worldwide:<br />

- 32 languages can be configured (including Asiatic and<br />

Cyrillic character sets)<br />

- Up to 5 languages are selectable online<br />

- Language-dependent texts and graphics<br />

■ Application<br />

The OP 73 operator panel can be used wherever the operator<br />

control and monitoring of machines and systems is performed<br />

directly on site – in manufacturing, process and building<br />

automation. They may be used in all kinds of industries and<br />

applications.<br />

Compatibility with OP3<br />

Same installation cutout as the OP3<br />

Transfer of the OP3 configurations from ProTool/Lite, ProTool to<br />

WinCC flexible<br />

Migration guide with description of the major changes to OP3 or<br />

ProTool<br />

■ Design<br />

3" LCD, 160 x 48 pixels, monochrome<br />

8 system keys, 4 user-configurable function keys<br />

Numerical and alphanumeric input option via cursor keys<br />

Compact design with low mounting depth<br />

Rugged plastic housing<br />

The front is resistant to various oils, greases and standard<br />

detergents<br />

Plug-type terminals for a 24 V DC power supply<br />

RS 485 interface for process connections (MPI,<br />

PROFIBUS DP up to 1.5 Mbit/s) and for configuration<br />

download<br />

2/101<br />

2


2<br />

Operator panels<br />

Panels — 70 series<br />

SIMATIC OP 73<br />

■ Function<br />

Input/output fields<br />

for displaying and changing process parameters<br />

Function keys<br />

for direct triggering of functions and actions. Up to<br />

16 functions can be configured simultaneously on function<br />

keys.<br />

Graphics<br />

can be used as icons instead of text to "label" function keys or<br />

buttons. They can also be used as simple on-screen graphics.<br />

In the configuration tool, a library is available containing an<br />

extensive range of graphics and a wide variety of objects. All<br />

editors with an OLE interface can be used as graphic editors<br />

(such as PaintShop, Designer or CorelDraw).<br />

Fixed texts<br />

for labeling function keys, process images and process<br />

values in different font sizes<br />

Bars are used for the graphical display of dynamic values<br />

Language selection during runtime<br />

- 5 online languages, 32 configuration languages incl. Asian<br />

and Cyrillic character sets<br />

- Language-dependent texts and graphics<br />

User administration (security)<br />

- Authentication with user ID and password<br />

- User-group-specific rights<br />

Signaling system<br />

- Discrete alarms<br />

- Analog alarms<br />

- Freely definable message classes (e.g., status/fault<br />

messages) for definition of acknowledgment response and<br />

display of message events<br />

- Message history<br />

Help texts<br />

for process images, messages and variables<br />

Arithmetic functions<br />

Limit value monitoring<br />

for reliable process control of inputs and outputs<br />

Indicator light<br />

for machine and plant status indication<br />

Scheduler for global function execution<br />

Template concept;<br />

Creation of screen templates (picture elements configured in<br />

the template appear in every screen)<br />

Simple maintenance and configuration thanks to:<br />

- backup and restoration of configuration, operating system<br />

and firmware on a <strong>PC</strong> using ProSave<br />

- configuration download via MPI/PROFIBUS DP or serially via<br />

RS485<br />

- individual contrast settings<br />

- no batteries are necessary<br />

Configuring<br />

Configuration is performed using the SIMATIC WinCC flexible<br />

Compact, Standard or Advanced engineering software, Version<br />

2004 SP1 plus HSP or higher, or with the SIMATIC WinCC<br />

(TIA Portal) Comfort or Professional engineering software, V11 or<br />

higher.<br />

For more information about engineering software, see<br />

HMI software/engineering software<br />

SIMATIC WinCC flexible/WinCC (TIA Portal).<br />

2/102<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Integration<br />

The OP 73 can be connected to:<br />

SIMATIC S7-200/-300/-400<br />

SIMATIC WinAC Software/Slot PLC<br />

Note:<br />

For further information, see "System interfaces".<br />

■ Technical specifications<br />

6AV6 641-0AA11-0AX0<br />

Product type designation OP 73<br />

Display<br />

Size 3"<br />

Display type <strong>ST</strong>N, black/white<br />

Resolution (pixels)<br />

Resolution (WxH in pixel) 160 x 48<br />

Backlighting<br />

MTBF backlighting (at 25 °C) about 100,000 hours<br />

Control elements<br />

Control elements Membrane keyboard<br />

Function keys, programmable 4 function keys<br />

Connection for<br />

- / - / -<br />

mouse/keyboard/barcode reader<br />

Keyboard<br />

System keys 8<br />

Numeric/alphabetical input Yes / Yes<br />

Supply voltage<br />

Input voltage<br />

permissible range +20.4 V to +28.8 V DC<br />

Supply voltage 24 V DC<br />

Input current<br />

Rated current 0.1 A<br />

Processor<br />

Processor ARM<br />

Memory<br />

Type Flash<br />

Usable memory for user data 256 KB usable memory for user<br />

data<br />

Time of day<br />

Clock<br />

Type Software clock, no battery<br />

backup<br />

Ambient conditions<br />

Operating temperature<br />

Operation (vertical installation) 0 °C to +50 °C<br />

Operation (max. tilt angle) 0 °C to +40 °C<br />

Storage/transport temperature<br />

Transport, storage -20 °C to +60 °C<br />

Relative humidity<br />

max. relative humidity 90 %<br />

Mounting position vertical<br />

maximum permissible angle of +/- <strong>80</strong> °<br />

inclination without external ventilation


■ Technical specifications (continued)<br />

6AV6 641-0AA11-0AX0<br />

Product type designation OP 73<br />

Degree and class of protection<br />

Front IP65, NEMA 4x, (when installed)<br />

Rear IP20<br />

Standards, approvals, certificates<br />

Certifications CE, GL, ABS, BV, DNV, LRS, UL,<br />

CSA, cULus, C-TICK, NEMA 4x<br />

Operating systems<br />

Operating system LINUX<br />

Configuration<br />

Configuration software<br />

Configuration tool see "Configuration software" from<br />

page 2/3<br />

Functionality under WinCC<br />

flexible/WinCC (TIA Portal)<br />

Task planner Yes<br />

Help system Yes<br />

Status/control Not possible<br />

With alarm logging system<br />

(incl. buffer and acknowledgment)<br />

Number of messages 500<br />

Bit messages Yes<br />

Analog messages Yes<br />

Message buffer Ring buffer (n x 256 entries),<br />

non-retentive<br />

Number of process images<br />

Process images 500<br />

Variables 1000<br />

Limit values Yes<br />

Multiplexing Yes<br />

Image elements<br />

Text objects 1,000 text elements<br />

Graphic object Bit maps, icons, icon (full-screen)<br />

dynamic objects Bar graphs<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Panels — 70 series<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC OP 73<br />

6AV6 641-0AA11-0AX0<br />

Product type designation OP 73<br />

Lists<br />

Text lists 150<br />

Graphic list 0<br />

Libraries Yes<br />

Security<br />

Number of user groups 50<br />

Passwords exportable Yes<br />

Number of user rights 32<br />

Recording<br />

Recording/Printing -<br />

Fonts<br />

Keyboard fonts US American (English)<br />

Languages<br />

Configuration languages D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified", DK, FIN, GR, J,<br />

KP / ROK, NL, N, PL, P, RUS, S,<br />

CZ / SK, TR, H<br />

Character sets WinCC flexible Standard, symbol<br />

languages<br />

Transfer (upload/download)<br />

Transfer of configuration MPI/PROFIBUS DP, serial,<br />

automatic transfer recognition<br />

Process coupling<br />

Connection to controller see "System interfaces" from<br />

page 2/178<br />

Expandability/openness<br />

Open Platform Program No<br />

Dimensions and weight<br />

Dimensions<br />

Front of enclosure (W x H) 154 mm x 84 mm<br />

Mounting cutout/device depth<br />

(W x H)<br />

Weight<br />

Weight 0.25 kg<br />

138 mm x 68 mm / 28.5 mm<br />

device depth<br />

2/103<br />

2


2<br />

Operator panels<br />

Panels — 70 series<br />

SIMATIC OP 73<br />

■ Ordering data Order No. ■ Dimensional drawings<br />

SIMATIC OP 73 6AV6 641-0AA11-0AX0<br />

Operator Panel with 3" display,<br />

monochrome, including mounting<br />

accessories<br />

Configuration<br />

with SIMATIC WinCC flexible or see HMI Software<br />

with SIMATIC WinCC (TIA Portal)<br />

Documentation<br />

(to be ordered separately)<br />

User Manual<br />

WinCC flexible Compact/<br />

Standard/Advanced<br />

German 6AV6 691-1AB01-3AA0<br />

English 6AV6 691-1AB01-3AB0<br />

French 6AV6 691-1AB01-3AC0<br />

Italian 6AV6 691-1AB01-3AD0<br />

Spanish 6AV6 691-1AB01-3AE0<br />

User Manual<br />

WinCC flexible Communication<br />

German 6AV6 691-1CA01-3AA0<br />

English 6AV6 691-1CA01-3AB0<br />

French 6AV6 691-1CA01-3AC0<br />

Italian 6AV6 691-1CA01-3AD0<br />

Spanish 6AV6 691-1CA01-3AE0<br />

SIMATIC HMI Manual Collection B 6AV6 691-1SA01-0AX0<br />

Electronic documentation, on<br />

DVD<br />

5 languages (English, French,<br />

German, Italian and Spanish);<br />

contains: all currently available<br />

user manuals, manuals and<br />

communication manuals for<br />

SIMATIC HMI<br />

Accessories see HMI accessories<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

2/104<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

All specifications in mm. Panel cutout see technical<br />

specifications.<br />

SIMATIC OP73<br />

154<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-panels<br />

28.5<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.<br />

84<br />

67.7<br />

G_<strong>ST</strong><strong>80</strong>_XX_00144


■ Overview<br />

Compact Operator Panel for operator control and monitoring<br />

of machines and plants<br />

Graphics in a new dimension – small and smart<br />

Pixel-graphics 4.5" LC display, monochrome<br />

23 system keys, 8 freely-configurable and freely-inscribable<br />

function keys (4 with LEDs)<br />

All interfaces (e.g. MPI, PROFIBUS DP) are onboard<br />

interfaces<br />

Together with OP 77B, successor of the successful OP7<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Panels — 70 series<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC OP 77A<br />

■ Benefits<br />

High-contrast display for good readability<br />

Large keys for high operational safety<br />

Simple handling and configuring<br />

Integral component of Totally Integrated Automation (TIA):<br />

Increases productivity, minimizes the engineering outlay,<br />

reduces the lifecycle costs<br />

Reduction in service and startup costs thanks to<br />

maintenance-free design (no battery) and long service life of<br />

the backlighting<br />

Can be used worldwide:<br />

- 32 languages can be configured (including Asiatic and<br />

Cyrillic character sets)<br />

- Up to 5 languages are selectable online<br />

- Language-dependent texts and graphics<br />

Graphic library is available completely with ready-to-use<br />

display objects<br />

■ Application<br />

OP 77A Operator Panels can be used wherever machines and<br />

systems are controlled and monitored locally - in production,<br />

process and building automation alike. They are used in all types<br />

of sectors and applications.<br />

Compatibility with OP7<br />

Same panel cutout as OP7<br />

Importing of OP7 configurations from ProTool/Lite, ProTool and<br />

ProTool/Pro to WinCC flexible<br />

Migration manual with description of most important differences<br />

from OP7 or ProTool<br />

■ Design<br />

4.5" LCD, 160 x 64 pixels, monochrome<br />

23 system keys, 8 freely-configurable and freely-inscribable<br />

function keys (4 with LEDs)<br />

Numeric and alphanumeric input facilities<br />

Compact design with shallow installation depth<br />

Rugged plastic housing<br />

The front is resistant to various oils, greases and standard<br />

detergents<br />

Plug-type terminals for connection of a 24 V DC power supply<br />

RS 485 interface for process links (MPI, PROFIBUS DP up to<br />

1.5 Mbit/s) and for downloading the configuration<br />

2/105<br />

2


2<br />

Operator panels<br />

Panels — 70 series<br />

SIMATIC OP 77A<br />

■ Function<br />

Permanent window and template concept for creating screen<br />

templates<br />

Input/output fields<br />

for displaying and changing process parameters<br />

Function keys<br />

are used for directly actuating functions and actions. Up to<br />

16 functions can be configured simultaneously on function<br />

keys.<br />

Graphics<br />

can be used as icons instead of text to "label" function keys or<br />

buttons. They can also be used as simple on-screen graphics.<br />

In the configuration tool, a library is available containing an<br />

extensive range of graphics and a wide variety of objects. All<br />

editors with an OLE interface can be used as graphic editors<br />

(such as PaintShop, Designer or CorelDraw).<br />

Fixed texts<br />

for labeling function keys, process images and process<br />

values in any character size<br />

Bars are used for the graphical display of dynamic values<br />

Display selection from the PLC<br />

supports operator prompting from the PLC<br />

Language selection during runtime<br />

- 5 online languages, 32 configuration languages incl. Asian<br />

and Cyrillic character sets<br />

- Language-dependent texts and graphics<br />

User administration (security) according to the requirements<br />

of various sectors<br />

- Authentication with user ID and password<br />

- User-group-specific rights<br />

Signaling system<br />

- Freely definable message classes (e.g., status/fault<br />

messages) for definition of acknowledgment response and<br />

display of message events<br />

- Message history<br />

Recipe management<br />

Help texts<br />

for process images, messages and variables<br />

Arithmetic functions<br />

Limit value monitoring<br />

for reliable process control of inputs and outputs<br />

Indicator light<br />

for machine and plant status indication<br />

Scheduler for cyclic function execution<br />

Template concept;<br />

Picture elements configured in the template appear in every<br />

picture<br />

Simple maintenance and configuration thanks to:<br />

- Backup and restoration of the configuration, operating<br />

system, data records and firmware on a <strong>PC</strong> using ProSave<br />

- Configuration download/upload via MPI/PROFIBUS DP and<br />

serially via RS 485<br />

- Individual contrast settings<br />

- No batteries are necessary<br />

Configuration<br />

Configuration is performed using the SIMATIC WinCC flexible<br />

Compact, Standard or Advanced configuration software,<br />

Version 2004 SP1 plus HSP or higher, or with the<br />

SIMATIC WinCC (TIA Portal) Comfort or Professional<br />

engineering software, V11 or higher.<br />

For more information about engineering software, see<br />

HMI software/engineering software<br />

SIMATIC WinCC flexible/WinCC (TIA Portal).<br />

2/106<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Integration<br />

The OP 77A can be connected to:<br />

SIMATIC S7-200/-300/-400<br />

SIMATIC WinAC Software/Slot PLC<br />

Non-<strong>Siemens</strong> controllers:<br />

- Allen Bradley<br />

- Mitsubishi<br />

- Modicon<br />

-Omron<br />

Note:<br />

For further information, see "System interfaces".<br />

■ Technical specifications<br />

6AV6 641-0BA11-0AX1<br />

Product type designation OP 77A<br />

Display<br />

Size 4.5"<br />

Display type <strong>ST</strong>N, black/white<br />

Resolution (pixels)<br />

Resolution (WxH in pixel) 160 x 64<br />

Backlighting<br />

MTBF backlighting (at 25 °C) about 100,000 hours<br />

Control elements<br />

Control elements Membrane keyboard<br />

Function keys, programmable 8 function keys, 4 with LEDs<br />

Connection for<br />

- / - / -<br />

mouse/keyboard/barcode reader<br />

Keyboard<br />

System keys 23<br />

Numeric/alphabetical input Yes / Yes<br />

Supply voltage<br />

Input voltage<br />

permissible range +20.4 V to +28.8 V DC<br />

Supply voltage 24 V DC<br />

Input current<br />

Rated current 0.2 A<br />

Processor<br />

Processor ARM<br />

Memory<br />

Type Flash / RAM<br />

Usable memory for user data 256 KB usable memory for user<br />

data<br />

Type of output<br />

LED colors Green<br />

Time of day<br />

Clock<br />

Type Software clock, no battery<br />

backup<br />

Interfaces<br />

USB port No<br />

<strong>PC</strong> card slot No<br />

CF card slot No<br />

Multi Media Card slot No<br />

Industrial Ethernet<br />

Industrial Ethernet interface No


■ Technical specifications (continued)<br />

6AV6 641-0BA11-0AX1<br />

Product type designation OP 77A<br />

Ambient conditions<br />

Operating temperature<br />

Operation (vertical installation) 0 °C to +50 °C<br />

Operation (max. tilt angle) 0 °C to +40 °C<br />

Storage/transport temperature<br />

Transport, storage -20 °C to +60 °C<br />

Relative humidity<br />

max. relative humidity 90 %<br />

Mounting position vertical<br />

maximum permissible angle of +/- <strong>80</strong> °<br />

inclination without external ventilation<br />

Degree and class of protection<br />

Front IP65, NEMA 4x, NEMA 12<br />

(when installed)<br />

Rear IP20<br />

Standards, approvals, certificates<br />

Certifications CE, GL, ABS, BV, DNV, LRS, FM<br />

Class I Div. 2, UL, CSA, cULus,<br />

EX-Zone 2 (in Vorbereitung),<br />

EX-Zone 22 (in Vorbereitung),<br />

C-TICK, NEMA 4x, NEMA 12<br />

Operating systems<br />

Operating system LINUX<br />

Configuration<br />

Configuration software<br />

Configuration tool see "Configuration overview" from<br />

page 2/3<br />

Functionality under WinCC<br />

flexible/WinCC (TIA Portal)<br />

Task planner Yes<br />

Help system Yes<br />

Status/control Not possible<br />

With alarm logging system<br />

(incl. buffer and acknowledgment)<br />

Number of messages 1000<br />

Bit messages Yes<br />

Analog messages Yes<br />

Message buffer Ring buffer (n x 256 entries),<br />

non-retentive<br />

Recipes<br />

Recipes 5<br />

Data records per recipe 20<br />

Entries per data record 20<br />

Recipe memory 32 KB integrated Flash<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Panels — 70 series<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC OP 77A<br />

6AV6 641-0BA11-0AX1<br />

Product type designation OP 77A<br />

Number of process images<br />

Process images 500<br />

Variables 1000<br />

Limit values Yes<br />

Multiplexing Yes<br />

Image elements<br />

Text objects 1,000 text elements<br />

Graphic object Bit maps, icons, icon (full-screen)<br />

dynamic objects Bar graphs<br />

Lists<br />

Text lists 300<br />

Graphic list 0<br />

Libraries Yes<br />

Security<br />

Number of user groups 50<br />

Passwords exportable Yes<br />

Number of user rights 32<br />

Recording<br />

Recording/Printing -<br />

Fonts<br />

Keyboard fonts US American (English)<br />

Languages<br />

Configuration languages D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified", DK, FIN, GR, J,<br />

KP / ROK, NL, N, PL, P, RUS, S,<br />

CZ / SK, TR, H<br />

Character sets WinCC flexible Standard, symbol<br />

languages<br />

Transfer (upload/download)<br />

Transfer of configuration MPI/PROFIBUS DP, serial,<br />

automatic transfer recognition<br />

Process coupling<br />

Connection to controller see "System interfaces" from<br />

page 2/178<br />

Expandability/openness<br />

Open Platform Program No<br />

Dimensions and weight<br />

Dimensions<br />

Front of enclosure (W x H) 150 mm x 186 mm<br />

Mounting cutout/device depth<br />

(W x H)<br />

Weight<br />

Weight 0.5 kg<br />

135 mm x 171 mm / 38.5 mm<br />

device depth<br />

2/107<br />

2


2<br />

Operator panels<br />

Panels — 70 series<br />

SIMATIC OP 77A<br />

■ Ordering data Order No. ■ Dimensional drawings<br />

SIMATIC OP 77A 6AV6 641-0BA11-0AX1<br />

Operator Panel with 4.5" display,<br />

monochrome, including mounting<br />

accessories<br />

Configuration<br />

with SIMATIC WinCC flexible or see HMI Software<br />

with SIMATIC WinCC (TIA Portal)<br />

Documentation<br />

(to be ordered separately)<br />

User Manual<br />

WinCC flexible Compact/<br />

Standard/Advanced<br />

German 6AV6 691-1AB01-3AA0<br />

English 6AV6 691-1AB01-3AB0<br />

French 6AV6 691-1AB01-3AC0<br />

Italian 6AV6 691-1AB01-3AD0<br />

Spanish 6AV6 691-1AB01-3AE0<br />

User Manual<br />

WinCC flexible Communication<br />

German 6AV6 691-1CA01-3AA0<br />

English 6AV6 691-1CA01-3AB0<br />

French 6AV6 691-1CA01-3AC0<br />

Italian 6AV6 691-1CA01-3AD0<br />

Spanish 6AV6 691-1CA01-3AE0<br />

SIMATIC HMI Manual Collection B 6AV6 691-1SA01-0AX0<br />

Electronic documentation,<br />

on DVD<br />

5 languages (English, French,<br />

German, Italian and Spanish);<br />

contains: all currently available<br />

user manuals, manuals and<br />

communication manuals for<br />

SIMATIC HMI<br />

Accessories see HMI accessories<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

2/108<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

All specifications in mm. Panel cutout see technical<br />

specifications.<br />

OP 77A<br />

150<br />

134<br />

170<br />

186<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-panels<br />

6.2<br />

38.5<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.<br />

G_<strong>ST</strong><strong>80</strong>_XX_00087


■ Overview<br />

Compact Operator Panel for operator control and monitoring<br />

of machines and plants<br />

Graphics in a new dimension – small and smart<br />

Pixel-graphics 4,5" LCD, monochrome<br />

23 system keys, 8 freely-configurable and freely-inscribable<br />

function keys (4 with LEDs)<br />

All interfaces (e.g. MPI, PROFIBUS DP) are onboard<br />

interfaces<br />

Non-<strong>Siemens</strong> PLCs can be connected using easy-to-use<br />

drivers<br />

Combined with OP 77A successor of the successful OP 7<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Panels — 70 series<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC OP 77B<br />

■ Benefits<br />

High-contrast display for good legibility<br />

Large keys for improved operational reliability<br />

Easy to handle and configure<br />

Integral component of Totally Integrated Automation (TIA):<br />

Increased productivity, minimum engineering overhead,<br />

reduction in life-cycle costs<br />

Reduction of service and commissioning costs through:<br />

- Remote downloading of the configuration with automatic<br />

transfer recognition even via WAN (Wide Area Network)<br />

- Maintenance-free design (no battery) and long service life of<br />

the backlighting<br />

Can be used worldwide:<br />

- 32 languages can be configured (incl. Asian and Cyrillic<br />

character sets)<br />

- Up to 5 languages can be switched online<br />

- Language-dependent texts and graphics<br />

Graphic library available with off-the-shelf picture objects<br />

Standard hardware and software interfaces for increasing<br />

flexibility:<br />

- Optional SD Card, can be used for recipe data sets and for<br />

backup of configuration/system data<br />

Integrated printer port (USB)<br />

■ Application<br />

OP 77B Operator Panels can be used wherever machines and<br />

systems are controlled and monitored locally - in production,<br />

process and building automation alike. They may be used in all<br />

kinds of industries and applications.<br />

Compatibility with OP7<br />

Same panel cutout as OP7<br />

Importing of OP7 configurations from ProTool/Lite, ProTool and<br />

ProTool/Pro to WinCC flexible<br />

Migration manual with description of most important differences<br />

from OP7 or ProTool<br />

■ Design<br />

4.5" LC display, 160 x 64 pixels, monochromatic<br />

23 system keys, 8 freely-configurable and freely-inscribable<br />

function keys (4 with LEDs)<br />

Numeric and alphanumeric input options<br />

Compact design with low mounting depth<br />

Rugged plastic enclosure<br />

The front is resistant to various oils, greases and standard<br />

detergents<br />

Plug-in terminals for 24 V DC power supply<br />

Interfaces:<br />

- RS 485/422 interface for process connections<br />

(MPI, PROFIBUS DP up to 12 Mbit/s)<br />

- RS 232 interface for process connections<br />

- USB printer interface<br />

Slot for Multi Media Card<br />

Slot for SD Card<br />

2/109<br />

2


2<br />

Operator panels<br />

Panels — 70 series<br />

SIMATIC OP 77B<br />

■ Function<br />

Permanent window and template concept for creating screen<br />

templates<br />

Input/output fields<br />

for displaying and changing process parameters<br />

Function keys<br />

for directly actuating functions and actions. Up to 16 functions<br />

can be configured simultaneously on function keys. They can<br />

be used directly as PROFIBUS DP input I/Os.<br />

Graphics<br />

can be used as icons instead of text to "label" function keys or<br />

buttons. They can also be used as simple on-screen graphics.<br />

In the configuration tool, a library is available containing an<br />

extensive range of graphics and a wide variety of objects. All<br />

editors with an OLE interface can be used as graphic editors<br />

(such as PaintShop, Designer or CorelDraw).<br />

Fixed texts<br />

for labeling function keys, process images and process<br />

values in any character size<br />

Bars are used for the graphical display of dynamic values<br />

Display selection from the PLC<br />

supports operator prompting from the PLC<br />

Language selection during runtime<br />

- 5 online languages, 32 configuration languages incl. Asian<br />

and Cyrillic character sets<br />

- Language-dependent texts and graphics<br />

User administration (security) according to the requirements<br />

of the various sectors<br />

- Authentication with user ID and password<br />

- User-group-specific rights<br />

Signaling system<br />

- Analog alarms<br />

- Bit messages as well as the Alarm S message frame<br />

procedure for SIMATIC S7<br />

- Freely definable message classes (e. g. status/fault<br />

messages) for definition of acknowledgment response and<br />

display of message events<br />

- Message history<br />

Recipe management<br />

- With additional data storage (on optional multi-media card)<br />

- Storage of recipe data in standard Windows format (CSV)<br />

- External processing using standard tools such as Excel and<br />

Access is possible<br />

Help texts<br />

for process images, messages and variables<br />

Arithmetic functions<br />

Limit value monitoring<br />

for reliable process control of inputs and outputs<br />

Indicator light<br />

for machine and plant status indication<br />

Scheduler (timer) for cyclic function execution<br />

Print<br />

hard copy, messages and user-configurable reports<br />

Template concept<br />

Picture elements configured in the template appear in every<br />

picture<br />

2/110<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

User-friendly maintenance and configuration thanks to:<br />

- Backup and restoring of the configuration, operating system,<br />

data records and firmware on the optional Multi Media Card<br />

- Backup and restoration of the configuration, operating<br />

system, data records and firmware on a <strong>PC</strong> using ProSave<br />

- Configuration download/upload via<br />

MPI/PROFIBUS DP/RS 232/USB<br />

- Automatic transfer identification<br />

- Individual contrast settings<br />

- Configuration simulation directly on the configuration<br />

computer<br />

- No batteries are necessary<br />

Configuration<br />

Configuration is performed using the SIMATIC WinCC flexible<br />

Compact, Standard or Advanced configuration software,<br />

Version 2004 or higher, or with the SIMATIC WinCC Comfort or<br />

Professional engineering software, V11 or higher.<br />

For more information about engineering software, see HMI<br />

software/engineering software SIMATIC WinCC flexible/WinCC.<br />

■ Integration<br />

The OP 77B can be connected to:<br />

SIMATIC S7-200/-300/-400<br />

SIMATIC WinAC Software/Slot PLC<br />

SIMATIC S5<br />

SIMATIC 505<br />

Non-<strong>Siemens</strong> controllers:<br />

- Allen Bradley<br />

- Mitsubishi<br />

- LG GLOFA GM<br />

- Modicon<br />

- GE-Fanuc<br />

-Omron<br />

Note:<br />

For further information, see "System interfaces".


■ Technical specifications<br />

6AV6 641-0CA01-0AX1<br />

Product type designation OP 77B<br />

Display<br />

Size 4.5"<br />

Display type <strong>ST</strong>N, black/white<br />

Resolution (pixels)<br />

Resolution (WxH in pixel) 160 x 64<br />

Backlighting<br />

MTBF backlighting (at 25 °C) about 100,000 hours<br />

Control elements<br />

Control elements Membrane keyboard<br />

Function keys, programmable 8 function keys, 4 with LEDs<br />

Connection for<br />

- / - / -<br />

mouse/keyboard/barcode reader<br />

Keyboard<br />

System keys 23<br />

Numeric/alphabetical input Yes / Yes<br />

Supply voltage<br />

Input voltage<br />

permissible range +20.4 V to +28.8 V DC<br />

Supply voltage 24 V DC<br />

Input current<br />

Rated current 0.2 A<br />

Processor<br />

Processor ARM<br />

Memory<br />

Type Flash / RAM<br />

Usable memory for user data 1000 KB usable memory for user<br />

data<br />

Type of output<br />

LED colors Green<br />

Time of day<br />

Clock<br />

Type Software clock, no battery<br />

backup<br />

Interfaces<br />

USB port 1 x USB<br />

Multimedia card combined<br />

Industrial Ethernet<br />

Industrial Ethernet interface No<br />

Ambient conditions<br />

Operating temperature<br />

Operation (vertical installation) 0 °C to +50 °C<br />

Operation (max. tilt angle) 0 °C to +40 °C<br />

Storage/transport temperature<br />

Transport, storage -20 °C to +60 °C<br />

Relative humidity<br />

max. relative humidity 90 %<br />

Mounting position vertical<br />

maximum permissible angle of +/- <strong>80</strong> °<br />

inclination without external ventilation<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Panels — 70 series<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC OP 77B<br />

6AV6 641-0CA01-0AX1<br />

Product type designation OP 77B<br />

Degree and class of protection<br />

Front IP65, NEMA 4x, NEMA 12<br />

(when installed)<br />

Rear IP20<br />

Standards, approvals,<br />

certificates<br />

Certifications CE, GL, ABS, BV, DNV, LRS, FM<br />

Class I Div. 2, UL, CSA, cULus,<br />

EX-Zone 2 (in Vorbereitung),<br />

EX-Zone 22 (in Vorbereitung),<br />

C-TICK, NEMA 4x, NEMA 12<br />

Operating systems<br />

Operating system Windows CE<br />

Configuration<br />

Configuration software<br />

Configuration tool see "Configuration overview" from<br />

page 2/3<br />

Functionality under WinCC<br />

flexible/WinCC (TIA portal)<br />

Task planner Yes<br />

Help system Yes<br />

With alarm logging system (incl.<br />

buffer and acknowledgment)<br />

Number of messages 1000<br />

Bit messages Yes<br />

Analog messages Yes<br />

Message buffer Ring buffer (n x 256 entries),<br />

non-retentive<br />

Recipes<br />

Recipes 100<br />

Data records per recipe 200<br />

Entries per data record 200<br />

Recipe memory 32 KB integrated Flash,<br />

expandable<br />

Number of process images<br />

Process images 500<br />

Variables 1000<br />

Limit values Yes<br />

Multiplexing Yes<br />

Image elements<br />

Text objects 2,500 text elements<br />

Graphic object Bit maps, icons, icon<br />

(full-screen)<br />

dynamic objects Bar graphs<br />

Lists<br />

Text lists 300<br />

Graphic list 0<br />

Libraries Yes<br />

2/111<br />

2


2<br />

Operator panels<br />

Panels — 70 series<br />

SIMATIC OP 77B<br />

■ Technical specifications (continued)<br />

■ Ordering data Order No.<br />

6AV6 641-0CA01-0AX1<br />

SIMATIC OP 77B E 6AV6 641-0CA01-0AX1<br />

Product type designation OP 77B<br />

Operator Panel with 4.5" display,<br />

Security<br />

Number of user groups 50<br />

monochrome, including mounting<br />

accessories<br />

Passwords exportable Yes<br />

Configuration<br />

Number of user rights 32<br />

with SIMATIC WinCC flexible or with see HMI Software<br />

Data carrier support<br />

SIMATIC WinCC (TIA Portal)<br />

Multimedia Card Yes<br />

Documentation<br />

Recording<br />

(to be ordered separately)<br />

Recording/Printing<br />

Printer driver<br />

Fonts<br />

Keyboard fonts<br />

Alarms, report (shift report),<br />

hardcopy<br />

ESC/P2, <strong>PC</strong>L3/<strong>PC</strong>L6<br />

US American (English)<br />

User Manual<br />

WinCC flexible<br />

Compact/Standard/Advanced<br />

German<br />

English<br />

French<br />

6AV6 691-1AB01-3AA0<br />

6AV6 691-1AB01-3AB0<br />

6AV6 691-1AB01-3AC0<br />

Languages<br />

Italian 6AV6 691-1AB01-3AD0<br />

Configuration languages<br />

Character sets<br />

D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified", DK, FIN, GR, J,<br />

KP / ROK, NL, N, PL, P, RUS, S,<br />

CZ / SK, TR, H<br />

Tahoma, WinCC flexible<br />

Standard, symbol languages,<br />

Spanish<br />

User Manual<br />

WinCC flexible Communication<br />

German<br />

English<br />

6AV6 691-1AB01-3AE0<br />

6AV6 691-1CA01-3AA0<br />

6AV6 691-1CA01-3AB0<br />

all freely scalable<br />

French 6AV6 691-1CA01-3AC0<br />

Transfer (upload/download)<br />

Italian 6AV6 691-1CA01-3AD0<br />

Transfer of configuration MPI/PROFIBUS DP, serial, USB, Spanish 6AV6 691-1CA01-3AE0<br />

by means of external storage<br />

medium, automatic transfer<br />

recognition<br />

SIMATIC HMI Manual Collection<br />

Electronic documentation, on DVD<br />

B 6AV6 691-1SA01-0AX0<br />

Process coupling<br />

5 languages (English, French,<br />

Connection to controller<br />

Expandability/openness<br />

see "System interfaces" from<br />

page 2/178<br />

German, Italian and Spanish);<br />

contains: all currently available user<br />

manuals, manuals and communication<br />

manuals for SIMATIC HMI<br />

Open Platform Program<br />

I/O<br />

No<br />

Accessories see HMI accessories<br />

I/O devices<br />

Dimensions and weight<br />

Dimensions<br />

Printer<br />

Front of enclosure (W x H) 150 mm x 186 mm<br />

Mounting cutout/device depth (W<br />

x H<br />

Weight<br />

Weight 0.5 kg<br />

2/112<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

135 mm x 171 mm / 38.5 mm<br />

device depth<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU


■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical<br />

specifications.<br />

OP 77B<br />

150<br />

134<br />

170<br />

186<br />

6.2<br />

38.5<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00087<br />

Operator panels<br />

Panels — 70 series<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-panels<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC OP 77B<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.<br />

2/113<br />

2


2<br />

Operator panels<br />

Panels —170 series<br />

SIMATIC TP 177A<br />

■ Overview<br />

Touch Panel for operator control and monitoring of small<br />

machines and plants<br />

Low-cost entry-level product in the category of touch panels<br />

with graphics capability and all the basic functions required<br />

for simple tasks<br />

Pixel graphics 5.7" <strong>ST</strong>N touch screen (analog/resistive),<br />

Blue mode (4 levels)<br />

All interfaces (e.g. MPI, PROFIBUS DP) are onboard<br />

SIMATIC TP 177A is the successor to the TP 170A Touch Panel<br />

2/114<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Can also be used in a vertical position where installation<br />

space is restricted<br />

Integral component of Totally Integrated Automation (TIA):<br />

Increased productivity, minimum engineering overhead,<br />

reduction in life-cycle costs<br />

Reduction of service and commissioning costs through:<br />

- Maintenance-free design (no battery) and long service life of<br />

the backlit display<br />

Graphic library available with off-the-shelf picture objects<br />

Can be used worldwide:<br />

- 32 languages can be configured (incl. Asian and Cyrillic<br />

character sets)<br />

- You can switch between up to 5 languages online<br />

- Language-dependent texts and graphics<br />

■ Application<br />

The TP 177A Touch Panels can be used wherever on-site<br />

operator control and monitoring of small machines and plants is<br />

required – in production automation, process automation and<br />

building automation. They may be used in all kinds of industries<br />

and applications.<br />

With its fast response times, the TP 177A is also suitable for<br />

jog mode.<br />

Compatible with TP 170A<br />

Same installation cutout as TP 170A<br />

Transfer of the TP 170A configurations from ProTool/Lite,<br />

ProTool to WinCC flexible<br />

Migration manual with descriptions of the essential changes to<br />

TP 170A or ProTool<br />

■ Design<br />

5.7” <strong>ST</strong>N, CCFL 1) -backlit display, Blue mode<br />

(4 shades of blue)<br />

Analog resistive Touch<br />

Numerical system keyboard for decimal, binary and<br />

hexadecimal number formats<br />

OnScreen alphabetic keyboard<br />

Compact design with low mounting depth<br />

Robust plastic housing<br />

The front is resistant to various oils, greases and standard<br />

detergents<br />

Plug-in terminals for 24 V DC power supply<br />

RS 485 interface for process connections (MPI, PROFIBUS DP<br />

up to 1.5 Mbit/s) and for the configuration download<br />

1) Cold Cathode Fluorescence Lamps


■ Function<br />

Templates concept for the creation of screen templates<br />

Input/output fields<br />

for displaying and changing process parameters<br />

Buttons<br />

are used for directly actuating functions and actions. Up to<br />

16 functions can be configured simultaneously on buttons.<br />

Graphics<br />

can be used as icons instead of text to "label" function keys or<br />

buttons. They can also be used as background displays<br />

(wallpaper).<br />

In the configuration tool, a library is available containing<br />

extensive graphics and a wide variety of objects. All editors<br />

with an OLE interface can be used as graphic editors<br />

(such as PaintShop, Designer or CorelDraw).<br />

Vector graphics<br />

Simple geometric basic forms (line, circle and rectangle) can<br />

be created directly in the configuring tool<br />

Fixed texts<br />

for labeling function keys, process screens and process<br />

values in different font sizes<br />

Curve functions and bars<br />

are used for the display of dynamic values in graphic-based<br />

format<br />

Language selection:<br />

- 5 online languages, 32 configuration languages incl. Asian<br />

and Cyrillic character sets<br />

- Language-dependent texts and graphics<br />

User administration (security) according to the requirements<br />

of the various sectors<br />

- Authentication with user ID and password<br />

- User-group-specific rights<br />

Signaling system<br />

- Discrete alarms<br />

- Analog alarms<br />

- Freely-definable message classes (e.g. status/fault<br />

messages) for definition of acknowledgment response and<br />

display of alarm events<br />

- Message history<br />

Recipe management<br />

Help texts<br />

for process images, messages and variables<br />

Arithmetic functions<br />

Limit value monitoring<br />

for reliable process control of inputs and outputs<br />

Indicator light<br />

for machine and plant status indication<br />

Scheduler for cyclic function execution<br />

Template concept<br />

Creation of picture templates (display elements configured in<br />

the template appear in every image)<br />

Simple maintenance and configuration thanks to:<br />

- Backup and restoration of configuration, operating system<br />

and firmware on a <strong>PC</strong> using ProSave<br />

- Configuration download via MPI/PROFIBUS DP and serially<br />

via RS485<br />

- Automatic transfer identification<br />

- Individual contrast setting and calibration<br />

- Clean screen<br />

- No batteries are necessary<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Panels —170 series<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC TP 177A<br />

Configuration<br />

Configuration is performed using the<br />

SIMATIC WinCC flexible Compact, Standard or Advanced<br />

engineering software, Version 2004 SP1 plus HSP or higher, or<br />

with the SIMATIC WinCC Comfort or Professional engineering<br />

software, V11 or higher.<br />

For more information about engineering software, see<br />

HMI software/engineering software<br />

SIMATIC WinCC flexible/WinCC (TIA Portal).<br />

■ Integration<br />

The TP 177A can be connected to:<br />

SIMATIC S7-200/-300/-400<br />

SIMATIC WinAC Software/Slot PLC<br />

Non-<strong>Siemens</strong> controllers:<br />

- Allen Bradley<br />

- Mitsubishi<br />

- Modicon<br />

-Omron<br />

Note:<br />

Further information can be found under "System interfaces".<br />

■ Technical specifications<br />

6AV6 642-0AA11-0AX1<br />

Product type designation TP 177A<br />

Display<br />

Size 5.7"<br />

Display type <strong>ST</strong>N, 4 shades of blue<br />

Resolution (pixels)<br />

Resolution (WxH in pixel) 320 x 240<br />

Backlighting<br />

MTBF backlighting (at 25 °C) about 50,000 hours<br />

Control elements<br />

Control elements Touch screen<br />

Connection for<br />

- / - / -<br />

mouse/keyboard/barcode reader<br />

Keyboard<br />

Numeric/alphabetical input Yes / Yes<br />

Touch operation<br />

Touch screen analog, resistive<br />

Supply voltage<br />

Input voltage<br />

permissible range +20.4 V to +28.8 V DC<br />

Supply voltage 24 V DC<br />

Input current<br />

Rated current 0.24 A<br />

Processor<br />

Processor ARM<br />

Memory<br />

Type Flash / RAM<br />

Type of output<br />

LED colors None<br />

2/115<br />

2


2<br />

Operator panels<br />

Panels —170 series<br />

SIMATIC TP 177A<br />

■ Technical specifications (continued)<br />

6AV6 642-0AA11-0AX1<br />

Product type designation TP 177A<br />

Time of day<br />

Clock<br />

Type Software clock, no battery<br />

backup<br />

Interfaces<br />

Interfaces 1 x RS422, 1 x RS485<br />

(max. 1.5 Mbit/s)<br />

USB port No<br />

<strong>PC</strong> card slot No<br />

CF card slot No<br />

Multi Media Card slot No<br />

Industrial Ethernet<br />

Industrial Ethernet interface No<br />

Ambient conditions<br />

Operating temperature<br />

Operation (vertical installation) 0 °C to +50 °C<br />

Operation (max. tilt angle) 0 °C to +40 °C<br />

Storage/transport temperature<br />

Transport, storage -20 °C to +60 °C<br />

Relative humidity<br />

max. relative humidity 90 %<br />

Mounting position vertical<br />

maximum permissible angle of +/- 35 °<br />

inclination without external ventilation<br />

Degree and class of protection<br />

Front IP65, NEMA 4x, (when installed)<br />

Rear IP20<br />

Standards, approvals, certificates<br />

Certifications CE, GL, ABS, BV, DNV, LRS, FM<br />

Class I Div. 2, UL, CSA, cULus,<br />

EX-Zone 2 (in Vorbereitung),<br />

EX-Zone 22 (in Vorbereitung),<br />

C-TICK, NEMA 4x<br />

Operating systems<br />

Operating system LINUX<br />

Configuration<br />

Configuration software<br />

Configuration tool see "Configuration overview" from<br />

page 2/3<br />

Functionality under WinCC<br />

flexible/WinCC (TIA Portal)<br />

Number of Visual Basic Scripts Not possible<br />

Task planner Yes<br />

Help system Yes<br />

Status/control Not possible<br />

With alarm logging system<br />

(incl. buffer and acknowledgment)<br />

Number of messages 1000<br />

Bit messages Yes<br />

Analog messages Yes<br />

Message buffer Ring buffer (n x 256 entries),<br />

non-retentive<br />

2/116<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV6 642-0AA11-0AX1<br />

Product type designation TP 177A<br />

Recipes<br />

Recipes 5<br />

Data records per recipe 20<br />

Entries per data record 20<br />

Recipe memory 32 KB integrated Flash<br />

Number of process images<br />

Process images 250<br />

Variables 500<br />

Limit values Yes<br />

Multiplexing Yes<br />

Image elements<br />

Text objects 1,000 text elements<br />

Graphic object Bit maps, icons, icon (full-screen),<br />

vector graphics<br />

dynamic objects Diagrams, bar graphs<br />

Lists<br />

Text lists 300<br />

Graphic list 100<br />

Libraries Yes<br />

Security<br />

Number of user groups 50<br />

Passwords exportable Yes<br />

Number of user rights 32<br />

Data carrier support<br />

<strong>PC</strong> card No<br />

CF card No<br />

Multimedia Card No<br />

Fonts<br />

Keyboard fonts US American (English)<br />

Languages<br />

Configuration languages D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified", DK, FIN, GR, J,<br />

KP / ROK, NL, N, PL, P, RUS, S,<br />

CZ / SK, TR, H<br />

Character sets Tahoma, WinCC flexible<br />

Standard, symbol languages,<br />

1 additional character set can be<br />

loaded<br />

Transfer (upload/download)<br />

Transfer of configuration MPI/PROFIBUS DP, serial,<br />

automatic transfer recognition<br />

Process coupling<br />

Connection to controller see "System interfaces" from<br />

page 2/178<br />

Expandability/openness<br />

Open Platform Program No<br />

Dimensions and weight<br />

Dimensions<br />

Front of enclosure (W x H) 212 mm x 156 mm<br />

Mounting cutout/device depth<br />

(W x H)<br />

Weight<br />

Weight 0.75 kg<br />

198 mm x 142 mm / 44 mm<br />

device depth


© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Panels —170 series<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC TP 177A<br />

■ Ordering data Order No. Order No.<br />

SIMATIC TP 177A A 6AV6 642-0AA11-0AX1<br />

User Manual<br />

Touch Panel with 5.7" <strong>ST</strong>N display,<br />

blue mode (4 levels), incl.<br />

mounting accessories<br />

WinCC flexible Communication<br />

German<br />

English<br />

6AV6 691-1CA01-3AA0<br />

6AV6 691-1CA01-3AB0<br />

Configuration<br />

with SIMATIC WinCC flexible or<br />

with SIMATIC WinCC (TIA Portal)<br />

see HMI Software<br />

French<br />

Italian<br />

Spanish<br />

6AV6 691-1CA01-3AC0<br />

6AV6 691-1CA01-3AD0<br />

6AV6 691-1CA01-3AE0<br />

Documentation<br />

SIMATIC HMI Manual Collection B 6AV6 691-1SA01-0AX0<br />

(to be ordered separately)<br />

Electronic documentation, on DVD<br />

Operating Instructions<br />

TP 177A, TP 177B, OP 177B<br />

5 languages (English, French,<br />

German, Italian and Spanish);<br />

German 6AV6 691-1DG01-0AA1<br />

contains: all currently available<br />

English<br />

French<br />

Italian<br />

6AV6 691-1DG01-0AB1<br />

6AV6 691-1DG01-0AC1<br />

6AV6 691-1DG01-0AD1<br />

user manuals, manuals and<br />

communication manuals for<br />

SIMATIC HMI<br />

Spanish<br />

User Manual<br />

WinCC flexible Compact/<br />

Standard/Advanced<br />

6AV6 691-1DG01-0AE1<br />

Accessories see HMI accessories<br />

German 6AV6 691-1AB01-3AA0<br />

English 6AV6 691-1AB01-3AB0<br />

French 6AV6 691-1AB01-3AC0<br />

Italian 6AV6 691-1AB01-3AD0<br />

Spanish 6AV6 691-1AB01-3AE0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

2/117<br />

2


2<br />

Operator panels<br />

Panels —170 series<br />

SIMATIC TP 177A<br />

■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical<br />

specifications.<br />

SIMATIC TP177A<br />

2/118<br />

212<br />

156<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

140<br />

44<br />

6.2<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00143<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-panels<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.


■ Overview<br />

Touch Panel with extensive functions for operator control and<br />

monitoring of machines and plants<br />

Pixel-graphics display with analog touch screen<br />

- 4.3" TFT widescreen color display or<br />

- 5.7" <strong>ST</strong>N blue mode/color display<br />

All interfaces for communication with <strong>Siemens</strong> SIMATIC S7<br />

(e.g. MPI, PROFIBUS DP) are onboard<br />

The PROFINET interface is onboard in the color version<br />

Drivers are also available for non-<strong>Siemens</strong> PLCs<br />

Content of message buffer is retained even when panel is<br />

disconnected without batteries<br />

The 4" version features 4 additional function keys for optimized<br />

operator control efficiency<br />

The SIMATIC TP 177B 6" is the innovative successor to the<br />

TP 170B Touch Panel<br />

The TP 177B PN/DP is also available with a stainless steel front<br />

(EN 1672-2). The stainless steel front is also appropriate, for<br />

example, for the increased demands of the food and<br />

beverages industry.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Operator panels<br />

Panels — 170 series<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC TP 177B<br />

Reduction of service and commissioning costs through:<br />

- Backup/restore via a process interface or optionally via a<br />

Multimedia Card/SD Card (also possible using a USB flash<br />

drive on the 4" panel)<br />

- Image and configuration download via all device interfaces<br />

- Maintenance-free structure and long service life of the<br />

backlighting<br />

The data in the message buffer are retained even when the<br />

panel is disconnected from the supply, without battery<br />

backup.<br />

Can be used worldwide:<br />

- 32 languages can be configured (incl. Asian and Cyrillic<br />

character sets)<br />

- Online language can be selected directly on the device<br />

Graphic library available with off-the-shelf picture objects<br />

Standard interfaces for increasing flexibility:<br />

- External Multimedia Card/SD Card, can be used for recipe<br />

data records and for backup of configuration/system data;<br />

on the 4" panel, this is also possible using a USB flash drive<br />

Integrated USB interface for connecting, for example,<br />

standard printers<br />

Simple engineering supported by comprehensive<br />

documentation on the SIMATIC HMI Manual Collection DVD<br />

Integral component of Totally Integrated Automation (TIA):<br />

Increases productivity, minimizes engineering outlay, reduces<br />

lifecycle costs<br />

The panel versions with stainless steel front can be optimally<br />

used in the food and beverages and pharmaceutical<br />

industries. The front panels are designed for easy cleaning<br />

and disinfecting. Liquids flow off automatically from the front<br />

panels. In addition, the stainless steel front (including gasket)<br />

provides protection against contamination by foods.<br />

■ Application<br />

Thanks to their practical functions and large user memory,<br />

TP 177B Touch Panels can be used wherever operator control<br />

and monitoring of machines and plants is necessary on site –<br />

whether in production automation, process automation or<br />

building-services automation.<br />

The TP 177B is available in two display sizes: 4.3" TFT<br />

widescreen display with 256 colors or 5.7" <strong>ST</strong>N display with<br />

256 colors or 4 blue levels. The 4" version features four additional<br />

function keys for optimized operator control efficiency. The color<br />

versions with integrated PROFINET I/O interface can be implemented<br />

with even greater flexibility. A USB interface is standard<br />

on all model types. A further highlight is the non-volatile<br />

message buffer included as standard that stores messages<br />

permanently without battery backup.<br />

2/119<br />

2


2<br />

Operator panels<br />

Panels — 170 series<br />

SIMATIC TP 177B<br />

■ Design<br />

Display versions<br />

- 4.3" TFT widescreen display with 256 colors or<br />

- 5.7" <strong>ST</strong>N display with 256 colors or 4 blue levels<br />

LED or CCFL 1) Backlighting with long service life<br />

Analog resistive touch screen<br />

Numeric and alphanumeric on-screen keyboard<br />

High performance thanks to RISC processor and 2 MB user<br />

memory, plus additional integrated recipe memory<br />

Data in the message buffer are retained even when panel is<br />

disconnected from the power supply, without batteries<br />

MPI, PROFIBUS DP interfaces (up to 12 MBaud) as well as<br />

USB 1.1 (max. 100 mA) onboard<br />

PROFINET interface is already onboard in the color versions<br />

Configuration of the 6" version with SIMATIC WinCC flexible<br />

2005 Compact or higher, the 4" version as of WinCC flexible<br />

2008 Compact<br />

Complete functionality for demanding tasks<br />

Comprehensive Reichert graphic library<br />

Multimedia Card/SD card<br />

can be used for standard Multimedia Cards or standard<br />

SD Cards (for backup/restoration or for backing up recipe<br />

data sets, the configuration, and system data); the 4" version<br />

also supports USB flash drives<br />

The SINUMERIK, Sm@rtAccess and Sm@rtService options<br />

can be used<br />

Service-friendly thanks to maintenance-free design and long<br />

service life of the backlighting display<br />

1) Cold Cathode Fluorescence Lamps<br />

■ Function<br />

Permanent window and template concept for creating screen<br />

templates<br />

Input/output fields<br />

for visualizing and editing process parameters<br />

Configurable buttons<br />

with up to 16 functions are also used to directly trigger<br />

functions and actions<br />

Indicator light<br />

for machine and plant status indication<br />

Fixed texts<br />

for labeling function keys, process images and process<br />

values in any character size<br />

Help texts<br />

for process images, messages and variables<br />

Vector graphics, graphics<br />

can be used as icons instead of text for "labeling" buttons.<br />

They can also be used as full-screen background pictures.<br />

In the configuration tool, a library is available containing<br />

extensive graphics and a wide variety of objects. All editors<br />

with an OLE interface (e.g., PaintShop, Designer or<br />

CorelDraw) can be used as graphic editors.<br />

2/120<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Curve functions and bars<br />

are used for the display of dynamic values in graphic-based<br />

format<br />

Dynamic positioning of objects and dynamic showing/hiding<br />

of objects<br />

Arithmetic functions, limit value monitoring<br />

for reliable process control with inputs and outputs<br />

Online language selection with 5 selectable languages,<br />

incl. Asian and Cyrillic languages,<br />

this also applies to language-specific graphics<br />

Scheduler<br />

for cyclic function execution<br />

Password protection (security)<br />

User management – Authentication by means of user ID and<br />

password, plus privileges specific to user groups, which is an<br />

integral part of SIMATIC<br />

Signaling system<br />

Freely definable message classes (acknowledgement<br />

behavior and display can be configured). Administration of<br />

status, fault and system messages. The alarm history is<br />

retained even if the device is switched off. Analog alarms (limit<br />

value messages) in addition to discrete alarms.<br />

Recipe management:<br />

- With additional data storage (on ext. storage medium)<br />

- Online/offline processing on the panel<br />

- Storage of recipe data in standard Windows format (CSV)<br />

- External processing using standard tools such as Excel and<br />

Access is possible<br />

Multimedia Card/SD card compatibility<br />

for external standard data carriers, can be used for<br />

backup/restoration or for transporting recipe data records;<br />

the 4" version also supports USB flash drives<br />

User-friendly maintenance and configuration thanks to:<br />

- Backup and restoration of the configuration, operating<br />

system, data records and firmware on a <strong>PC</strong> using ProSave<br />

- Option to download/upload the configuration via all device<br />

interfaces (with automatic transfer detection)<br />

- Individual contrast and brightness setting and calibration<br />

- Configuration simulation directly on the configuration<br />

computer<br />

Configuration<br />

The configuration is implemented using the innovative<br />

SIMATIC WinCC Comfort engineering tool. Projects generated<br />

using WinCC flexible can be easily migrated to WinCC.<br />

Additional options<br />

Sm@rtServer<br />

Remote control and monitoring of SIMATIC HMI systems<br />

based on TCP/IP networks


■ Technical specifications<br />

Operator panels<br />

Panels — 170 series<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC TP 177B<br />

6AV6 642-0BD01-3AX0 6AV6 642-0BC01-1AX1 6AV6 642-0BA01-1AX1<br />

Product type designation<br />

Display<br />

TP 177B Widescreen TP 177 Blue mode TP 177B color<br />

Size 4.3" (95 mm x 53 mm) 5.7" (120 mm x 90 mm) 5.7" (120 mm x 90 mm)<br />

Display type<br />

Resolution (pixels)<br />

TFT, 256 colors <strong>ST</strong>N, 4 shades of blue <strong>ST</strong>N, 256 colors<br />

Resolution (WxH in pixel)<br />

Backlighting<br />

4<strong>80</strong> x 272 320 x 240 320 x 240<br />

MTBF backlighting (at 25 °C)<br />

Control elements<br />

Approx. 30000 hours about 50,000 hours about 50,000 hours<br />

Control elements Membrane keyboard Touch screen Touch screen<br />

Function keys, programmable 4 function keys<br />

Connection for<br />

mouse/keyboard/barcode reader<br />

Keyboard<br />

USB / USB / USB USB / USB / USB USB / USB / USB<br />

Numeric/alphabetical input<br />

Touch operation<br />

Yes (on-screen keyboard) / Yes<br />

(on-screen keyboard)<br />

Yes / Yes Yes / Yes<br />

Touch screen<br />

Supply voltage<br />

Input voltage<br />

analog, resistive analog, resistive analog, resistive<br />

permissible range +19.2 V to +28.8 V DC +20.4 V to +28.8 V DC +20.4 V to +28.8 V DC<br />

Supply voltage<br />

Input current<br />

24 V DC 24 V DC 24 V DC<br />

Rated current<br />

Processor<br />

0.2 A 0.24 A 0.24 A<br />

Processor<br />

Memory<br />

RISC 32-bit, 266 MHz ARM, 200 MHz ARM, 200 MHz<br />

Type Flash / RAM Flash / RAM Flash / RAM<br />

Usable memory for user data 2048 KB usable memory for user<br />

data<br />

Time of day<br />

Clock<br />

Type Hardware clock, synchronizable,<br />

no battery backup<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

2048 KB usable memory for user<br />

data<br />

Hardware clock, synchronizable,<br />

no battery backup<br />

2048 KB usable memory for user<br />

data<br />

Hardware clock, synchronizable,<br />

no battery backup<br />

Interfaces<br />

USB port 1 x USB 1 x USB 1 x USB<br />

<strong>PC</strong> card slot No No No<br />

CF card slot No No No<br />

Multimedia card<br />

Industrial Ethernet<br />

combined combined combined<br />

Industrial Ethernet interface<br />

Protocols<br />

Protocols (terminal link)<br />

1 x Ethernet (RJ45) No 1 x Ethernet (RJ45)<br />

Sm@rtAccess<br />

Ambient conditions<br />

Operating temperature<br />

Yes Yes Yes<br />

Operation (vertical installation) 0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °C<br />

Operation (max. tilt angle)<br />

Storage/transport temperature<br />

0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C<br />

Transport, storage<br />

Relative humidity<br />

-20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C<br />

max. relative humidity 90 % 90 % 90 %<br />

Mounting position vertical vertical vertical<br />

maximum permissible angle of<br />

inclination without external<br />

ventilation<br />

+/- 35 ° +/- 35 ° +/- 35 °<br />

2/121<br />

2


2<br />

Operator panels<br />

Panels — 170 series<br />

SIMATIC TP 177B<br />

■ Technical specifications (continued)<br />

Degree and class of protection<br />

Front IP65, NEMA 4, NEMA 4x, NEMA 12<br />

(when installed)<br />

2/122<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

IP65, NEMA 4x, NEMA 12<br />

(when installed)<br />

Rear IP20 IP20 IP20<br />

Standards, approvals, certificates<br />

Certifications CE, GL, FM Class I Div. 2, cULus,<br />

C-TICK, NEMA 4, NEMA 4x,<br />

NEMA 12<br />

CE, GL, ABS, BV, DNV, LRS, FM<br />

Class I Div. 2, UL, CSA, cULus,<br />

EX Zone 2, EX Zone 22, C-TICK,<br />

NEMA 4x, NEMA 12<br />

IP65, NEMA 4x, NEMA 12<br />

(when installed)<br />

CE, GL, ABS, BV, DNV, LRS, FM<br />

Class I Div. 2, UL, CSA, cULus,<br />

EX Zone 2, EX Zone 22, C-TICK,<br />

NEMA 4x, NEMA 12<br />

Operating systems<br />

Operating system<br />

Configuration<br />

Configuration software<br />

Windows CE (Version 5) Windows CE Windows CE<br />

Configuration tool<br />

Functionality under WinCC<br />

flexible/WinCC (TIA Portal)<br />

see "Configuration overview" from page 2/3<br />

Applications/options See chapter 4: HMI software/SIMATIC WinCC flexible options and SIMATIC WinCC (TIA portal) options<br />

Task planner Yes Yes Yes<br />

Help system Yes Yes Yes<br />

Status/control<br />

With alarm logging system<br />

(incl. buffer and acknowledgment)<br />

with SIMATIC S7 with SIMATIC S7 with SIMATIC S7<br />

Number of messages 2000 2000 2000<br />

Bit messages Yes Yes Yes<br />

Analog messages Yes Yes Yes<br />

Message buffer Ring buffer (n x 256 entries),<br />

retentive, maintenance-free<br />

Ring buffer (n x 256 entries),<br />

retentive, maintenance-free<br />

Recipes<br />

Recipes 100 100 100<br />

Data records per recipe 200 200 200<br />

Entries per data record 200 200 200<br />

Recipe memory 32 KB integrated Flash,<br />

expandable<br />

32 KB integrated Flash,<br />

expandable<br />

Ring buffer (n x 256 entries),<br />

retentive, maintenance-free<br />

32 KB integrated Flash,<br />

expandable<br />

Number of process images<br />

Process images 500 500 500<br />

Variables 1000 1000 1000<br />

Limit values Yes Yes Yes<br />

Multiplexing<br />

Image elements<br />

Yes Yes Yes<br />

Text objects 2,500 text elements 2,500 text elements 2,500 text elements<br />

Graphic object Bit maps, icons, icon (full-screen), Bit maps, icons, icon (full-screen), Bit maps, icons, icon (full-screen),<br />

vector graphics<br />

vector graphics<br />

vector graphics<br />

dynamic objects Diagrams, bar graphs, sliders,<br />

analog display, invisible buttons<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV6 642-0BD01-3AX0 6AV6 642-0BC01-1AX1 6AV6 642-0BA01-1AX1<br />

Product type designation TP 177B Widescreen TP 177 Blue mode TP 177B color<br />

Diagrams, bar graphs, sliders,<br />

analog display, invisible buttons<br />

Lists<br />

Text lists 300 300 300<br />

Graphic list 100 100 100<br />

Libraries<br />

Security<br />

Yes Yes Yes<br />

Number of user groups 50 50 50<br />

Passwords exportable Yes Yes Yes<br />

Number of user rights<br />

Data carrier support<br />

32 32 32<br />

<strong>PC</strong> card No No No<br />

CF card No No No<br />

Multimedia Card Yes Yes Yes<br />

Diagrams, bar graphs, sliders,<br />

analog display, invisible buttons


© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Panels — 170 series<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC TP 177B<br />

■ Technical specifications (continued)<br />

6AV6 642-0BD01-3AX0 6AV6 642-0BC01-1AX1 6AV6 642-0BA01-1AX1<br />

Product type designation<br />

Recording<br />

TP 177B Widescreen TP 177 Blue mode TP 177B color<br />

Recording/Printing Alarms, report (shift report), color Alarms, report (shift report), Alarms, report (shift report), color<br />

print, hardcopy<br />

hardcopy<br />

print, hardcopy<br />

Printer driver<br />

Fonts<br />

ESC/P2, <strong>PC</strong>L3/<strong>PC</strong>L6 ESC/P2, <strong>PC</strong>L3/<strong>PC</strong>L6 ESC/P2, <strong>PC</strong>L3/<strong>PC</strong>L6<br />

Keyboard fonts<br />

Languages<br />

US American (English) US American (English) US American (English)<br />

Configuration languages D, GB, F, I, E, CHN "traditional", D, GB, F, I, E, CHN "traditional", D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified", DK, FIN, GR, J, CHN "simplified", DK, FIN, GR, J, CHN "simplified", DK, FIN, GR, J,<br />

KP / ROK, NL, N, PL, P, RUS, S, KP / ROK, NL, N, PL, P, RUS, S, KP / ROK, NL, N, PL, P, RUS, S,<br />

CZ / SK, TR, H<br />

CZ / SK, TR, H<br />

CZ / SK, TR, H<br />

Character sets Tahoma, WinCC flexible Standard, Tahoma, Courier New, WinCC Tahoma, Courier New, WinCC<br />

symbol languages, 1 additional flexible Standard, symbol<br />

flexible Standard, symbol<br />

character sets can be loaded, all languages, 2 additional character languages, 2 additional character<br />

freely scalable<br />

sets can be loaded, all freely sets can be loaded, all freely<br />

Transfer (upload/download)<br />

scalable<br />

scalable<br />

Transfer of configuration MPI/PROFIBUS DP, serial, USB, MPI/PROFIBUS DP, serial, USB, MPI/PROFIBUS DP, serial, USB,<br />

Ethernet, by means of external by means of external storage Ethernet, by means of external<br />

storage medium, automatic medium, automatic transfer storage medium, automatic<br />

Process coupling<br />

transfer recognition<br />

recognition<br />

transfer recognition<br />

Connection to controller<br />

Expandability/openness<br />

see "System interfaces" from page 178<br />

Open Platform Program<br />

I/O<br />

Yes Yes Yes<br />

I/O devices<br />

Dimensions and weight<br />

Dimensions<br />

Printer Printer Printer<br />

Front of enclosure (W x H) 140 mm x 116 mm 212 mm x 156 mm 212 mm x 156 mm<br />

Mounting cutout/device depth 123 mm x 99 mm/48 mm device 198 mm x 142 mm / 44 mm device 198 mm x 142 mm / 44 mm device<br />

(W x H)<br />

Weight<br />

depth<br />

depth<br />

depth<br />

Weight 0.5 kg; Max. 0.8 kg 0.8 kg<br />

2/123<br />

2


2<br />

Operator panels<br />

Panels — 170 series<br />

SIMATIC TP 177B<br />

■ Ordering data Order No. Order No.<br />

SIMATIC TP 177B<br />

Documentation<br />

Touch Panel with<br />

(to be ordered separately)<br />

4.3" TFT widescreen color<br />

display (256 colors)<br />

5.7" <strong>ST</strong>N blue mode display<br />

(4 levels)<br />

E<br />

E<br />

6AV6 642-0BD01-3AX0<br />

6AV6 642-0BC01-1AX1<br />

Operating Instructions<br />

TP 177micro/TP 177A/TP 177B/<br />

OP 177B (WinCC flexible)<br />

German 6AV6 691-1DG01-0AA1<br />

5.7" <strong>ST</strong>N color display E 6AV6 642-0BA01-1AX1<br />

English 6AV6 691-1DG01-0AB1<br />

(256 colors)<br />

French 6AV6 691-1DG01-0AC1<br />

incl. mounting accessories<br />

Italian 6AV6 691-1DG01-0AD1<br />

TP 177B 4" starter kit<br />

Consisting of:<br />

E 6AV6 652-2KA00-0AA0<br />

Spanish<br />

User Manual<br />

WinCC flexible<br />

6AV6 691-1DG01-0AE1<br />

TP 177B with 4.3" TFT<br />

Compact/Standard/Advanced<br />

widescreen color display<br />

(256 colors)<br />

SIMATIC WinCC flexible<br />

Compact configuration software<br />

SIMATIC HMI Manual Collection<br />

(DVD), 5 languages (English,<br />

German<br />

English<br />

French<br />

Italian<br />

Spanish<br />

6AV6 691-1AB01-3AA0<br />

6AV6 691-1AB01-3AB0<br />

6AV6 691-1AB01-3AC0<br />

6AV6 691-1AB01-3AD0<br />

6AV6 691-1AB01-3AE0<br />

French, German, Italian,<br />

Spanish)<br />

User Manual<br />

WinCC flexible Communication<br />

MPI cable (5 m) (for download<br />

and test purposes only)<br />

German<br />

English<br />

6AV6 691-1CA01-3AA0<br />

6AV6 691-1CA01-3AB0<br />

TP 177B 6" starter kit E 6AV6 551-2EA01-1AA0<br />

French 6AV6 691-1CA01-3AC0<br />

Consisting of:<br />

Italian 6AV6 691-1CA01-3AD0<br />

TP 177B with 5.7" <strong>ST</strong>N color<br />

Spanish 6AV6 691-1CA01-3AE0<br />

display (256 colors)<br />

Configuration software SIMATIC<br />

WinCC flexible Compact<br />

SIMATIC HMI Manual Collection<br />

SIMATIC HMI Manual Collection B<br />

Electronic documentation,<br />

on DVD<br />

6AV6 691-1SA01-0AX0<br />

(DVD), 5 languages (English,<br />

5 languages (English, French,<br />

French, German, Italian,<br />

German, Italian and Spanish);<br />

Spanish)<br />

contains: all currently available<br />

MPI cable (5 m) (for download<br />

user manuals, manuals and<br />

and test purposes only),<br />

communication manuals for<br />

<strong>PC</strong>/PPI cable<br />

SIMATIC HMI<br />

Configuration software<br />

Accessories see HMI accessories<br />

With SIMATIC WinCC flexible or<br />

SIMATIC WinCC<br />

Configuration set<br />

Consisting of:<br />

SIMATIC WinCC flexible Compact<br />

engineering software,<br />

SIMATIC HMI Manual Collection<br />

(DVD), 5 languages (English,<br />

French, German, Italian and<br />

Spanish), <strong>PC</strong>/PPI cable Multimaster,<br />

MPI cable (5 m) (for<br />

download and test purposes only)<br />

see HMI software<br />

with SIMATIC WinCC flexible<br />

Compact engineering software<br />

D 6AV6 621-0AA01-0AA0<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

2/124<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical<br />

specifications.<br />

140<br />

122<br />

SIMATIC TP 177B, 4" version<br />

212<br />

196<br />

116<br />

156<br />

98<br />

SIMATIC TP 177B PN/DP and DP, 6" versions<br />

140<br />

6.2<br />

48<br />

6<br />

44<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00353<br />

G_<strong>ST</strong><strong>80</strong>_XX_00293<br />

Operator panels<br />

Panels — 170 series<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-panels<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC TP 177B<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.<br />

2/125<br />

2


2<br />

Operator panels<br />

Panels — 170 series<br />

SIMATIC OP 177B<br />

■ Overview<br />

Touch/Key Panel with extensive functions for operator control<br />

and monitoring of machines and plants<br />

Content of message buffer is retained even when panel is<br />

disconnected, without batteries<br />

Pixel-graphics <strong>ST</strong>N blue-mode/color display with analog<br />

touch screen and additional 32 function keys<br />

Interfaces for communication with <strong>Siemens</strong> SIMATIC S7<br />

(e.g. MPI, PROFIBUS DP) are onboard<br />

Ethernet is onboard in the color version<br />

Drivers are also available for non-<strong>Siemens</strong> PLCs<br />

Installation compatible with OP17<br />

2/126<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Reduction of service and commissioning costs through:<br />

- Backup/restoration via a process interface or optionally via a<br />

Multimedia Card/SD Card<br />

- Remote downloading of the configuration with automatic<br />

transfer recognition via all device interfaces<br />

- Maintenance-free design (no battery) and long service life of<br />

the backlighting<br />

- System keys that can be assigned to any function keys and<br />

used as an alternative to or in parallel with the on-screen<br />

keyboard<br />

Maintenance-free message buffer<br />

Can be used worldwide:<br />

- 32 languages can be configured (incl. Asian and Cyrillic<br />

character sets)<br />

- Online language can be selected directly on the device<br />

Language-dependent texts and graphics<br />

Graphic library available with off-the-shelf picture objects<br />

Standard interfaces for increasing the flexibility:<br />

- External Multimedia Card/SD Card, used for recipe data sets<br />

and for backup of the configuration/system data<br />

Integrated USB interface for connecting, for example,<br />

standard printers<br />

Simple engineering supported by comprehensive<br />

documentation on the SIMATIC HMI Manual Collection DVD<br />

Integral component of Totally Integrated Automation (TIA):<br />

Increases productivity, minimizes engineering outlay, reduces<br />

lifecycle costs<br />

■ Application<br />

Thanks to their practical functions and large user memory,<br />

OP 177B Operator Panels can be used wherever operator<br />

control and monitoring of machines and plants is necessary on<br />

site – whether in production automation, process automation or<br />

building-services automation.<br />

The OP 177B is available with a 4-color blue mode display or a<br />

256-color <strong>ST</strong>N display. The color version complete with an<br />

integrated PROFINET I/O interface can be implemented with<br />

even greater flexibility. A USB port is standard on both model<br />

types. A further highlight is the non-volatile message buffer<br />

included as standard that stores messages permanently without<br />

battery backup.


■ Design<br />

256 colors with color display or 4 blue-mode monochrome<br />

<strong>ST</strong>N display<br />

CCFL 1) Backlighting with long service life<br />

Analog resistive touch screen and membrane keyboard with<br />

32 function keys<br />

Numeric and alphanumeric on-screen keyboard<br />

High performance thanks to RISC processor and 2 MB user<br />

memory, plus additional integrated recipe memory<br />

The data in the message buffer are retained even when panel<br />

is disconnected from the power supply, without batteries<br />

MPI, PROFIBUS DP interfaces (up to 12 Mbaud) as well as<br />

USB 1.1 (max. 100 mA) onboard<br />

Ethernet (PROFINET I/O-capable) with the color version<br />

Integrated USB interface<br />

Can be configured using SIMATIC WinCC flexible 2005<br />

Compact and higher<br />

Complete functionality for demanding tasks<br />

Comprehensive Reichert graphic library<br />

Multimedia Card/SD Card slot<br />

Multimedia Cards or Standard SD Cards, can be used for<br />

standard Multimedia Cards (for backing up recipe data sets,<br />

the configuration, and system data)<br />

Remote downloading of the configuration via all interfaces<br />

with automatic transfer recognition<br />

The SINUMERIK, Sm@rtAccess and Sm@rtService options<br />

can be used<br />

Service-friendly thanks to maintenance-free design and long<br />

service life of the backlighting display<br />

1) Cold Cathode Fluorescence Lamps<br />

■ Function<br />

Permanent window and template concept for creating screen<br />

templates<br />

Input/output fields<br />

for visualizing and editing process parameters<br />

Configurable buttons<br />

with up to 16 functions are also used to directly trigger<br />

functions and actions<br />

Indicator light<br />

for machine and plant status indication<br />

Fixed texts<br />

for labeling function keys, process images and process<br />

values in any character size<br />

Help texts<br />

for process displays, messages, and variables<br />

Vector graphics, graphics<br />

can be used as icons instead of text for "labeling" buttons.<br />

They can also be used as full-screen background images.<br />

The configuration tool contains a library with extensive<br />

graphics and diverse objects. All editors with an OLE interface<br />

can be used as graphic editors (such as PaintShop, Designer<br />

or CorelDraw).<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Panels — 170 series<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC OP 177B<br />

Curve functions and bars<br />

are used for the display of dynamic values in graphic-based<br />

format<br />

Dynamic positioning of objects and dynamic showing/hiding<br />

of objects<br />

Arithmetic functions, limit value monitoring<br />

for reliable process control with inputs and outputs<br />

Online language selection with 5 selectable languages, incl.<br />

Asian and Cyrillic languages<br />

this also applies to language-specific graphics<br />

Scheduler<br />

for cyclic function execution<br />

Password protection (security)<br />

User management – Authentication by means of user ID and<br />

password, plus privileges specific to user groups, which is an<br />

integral part of SIMATIC<br />

Signaling system;<br />

Freely definable message classes (acknowledgement<br />

behavior and display can be configured), administration of<br />

status, fault and system alarms. The message history is<br />

retained even if the device is switched off.<br />

Analog alarms (limit value messages) in addition to bit<br />

messages<br />

Recipe management<br />

- With additional data storage (on ext. storage medium)<br />

- Online/offline processing on the panel<br />

- Storage of recipe data in standard Windows format (CSV)<br />

- External processing using standard tools such as Excel and<br />

Access is possible<br />

Multimedia Card/SD Card compatibility<br />

for external standard data carriers, can be used for<br />

backup/restoration or for transporting recipe data records<br />

User-friendly maintenance and configuration thanks to:<br />

- backup and restoration of the configuration, operating<br />

system, data records and firmware on a <strong>PC</strong> using ProSave<br />

- Option to download/upload the configuration via all device<br />

interfaces (with automatic transfer detection)<br />

- Individual contrast setting and calibration<br />

- Configuration simulation directly on the configuration<br />

computer<br />

Configuration<br />

The configuration is implemented using the innovative<br />

SIMATIC WinCC Comfort engineering tool. Projects generated<br />

using WinCC flexible can be easily migrated to WinCC.<br />

Additional options<br />

Sm@rtServer<br />

Remote control and monitoring of SIMATIC HMI systems<br />

based on TCP/IP networks<br />

2/127<br />

2


2<br />

Operator panels<br />

Panels — 170 series<br />

SIMATIC OP 177B<br />

■ Technical specifications<br />

6AV6 642-0DC01- 6AV6 642-0DA01-<br />

1AX1<br />

1AX1<br />

Product type<br />

designation<br />

Display<br />

OP 177B blue mode OP 177B color<br />

Size 5.7"<br />

5.7"<br />

(120 mm x 90 mm) (120 mm x 90 mm)<br />

Display type<br />

Resolution (pixels)<br />

<strong>ST</strong>N, 4 shades of blue <strong>ST</strong>N, 256 colors<br />

Resolution<br />

(WxH in pixel)<br />

Backlighting<br />

320 x 240 320 x 240<br />

MTBF backlighting<br />

(at 25 °C)<br />

Control elements<br />

about 50,000 hours about 50,000 hours<br />

Control elements Membrane keyboard Membrane keyboard<br />

Function keys,<br />

32 function keys, 32 function keys,<br />

programmable<br />

26 with LEDs 26 with LEDs<br />

Connection for<br />

mouse/keyboard/barco<br />

de reader<br />

USB / USB / USB USB / USB / USB<br />

Keyboard<br />

Numeric/alphabetical<br />

input<br />

Touch operation<br />

Yes / Yes Yes / Yes<br />

Touch screen analog, resistive analog, resistive<br />

Supply voltage<br />

Input voltage<br />

permissible range +20.4 V to<br />

+28.8 V DC<br />

2/128<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

+20.4 V to<br />

+28.8 V DC<br />

Supply voltage<br />

Input current<br />

24 V DC 24 V DC<br />

Rated current<br />

Processor<br />

0.24 A 0.24 A<br />

Processor<br />

Memory<br />

ARM, 200 MHz ARM, 200 MHz<br />

Type Flash / RAM Flash / RAM<br />

Usable memory for user<br />

data<br />

2048 KB usable<br />

memory for user data<br />

Type of output<br />

LED colors Green Green<br />

Time of day<br />

Clock<br />

Type Hardware clock,<br />

synchronizable, no<br />

battery backup<br />

2048 KB usable<br />

memory for user data<br />

Hardware clock,<br />

synchronizable, no<br />

battery backup<br />

Interfaces<br />

USB port 1 x USB 1 x USB<br />

<strong>PC</strong> card slot No No<br />

CF card slot No No<br />

Multimedia card<br />

Industrial Ethernet<br />

combined combined<br />

Industrial Ethernet<br />

interface<br />

Protocols<br />

Protocols (terminal link)<br />

No 1 x Ethernet (RJ45)<br />

Sm@rtAccess Yes Yes<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV6 642-0DC01- 6AV6 642-0DA01-<br />

1AX1<br />

1AX1<br />

Product type<br />

designation<br />

Ambient conditions<br />

Operating temperature<br />

OP 177B blue mode OP 177B color<br />

Operation<br />

(vertical installation)<br />

0 °C to +50 °C 0 °C to +50 °C<br />

Operation<br />

(max. tilt angle)<br />

Storage/transport<br />

temperature<br />

0 °C to +40 °C 0 °C to +40 °C<br />

Transport, storage<br />

Relative humidity<br />

-20 °C to +60 °C -20 °C to +60 °C<br />

max. relative humidity 90 % 90 %<br />

Mounting position vertical vertical<br />

maximum permissible<br />

angle of inclination<br />

without external ventilation<br />

+/- 35 ° +/- 35 °<br />

Degree and class of<br />

protection<br />

Front IP65, NEMA 4x,<br />

NEMA 12 (when<br />

installed)<br />

Rear IP20 IP20<br />

Standards, approvals,<br />

certificates<br />

Certifications CE, GL, ABS, BV,<br />

DNV, LRS, FM Class I<br />

Div. 2, UL, CSA,<br />

cULus, EX Zone 2,<br />

EX Zone 22, C-TICK,<br />

NEMA 4x, NEMA 12<br />

IP65, NEMA 4x,<br />

NEMA 12 (when<br />

installed)<br />

CE, GL, ABS, BV,<br />

DNV, LRS, FM Class I<br />

Div. 2, UL, CSA,<br />

cULus, EX Zone 2,<br />

EX Zone 22, C-TICK,<br />

NEMA 4x, NEMA 12<br />

Operating systems<br />

Operating system<br />

Configuration<br />

Configuration software<br />

Windows CE Windows CE<br />

Configuration tool<br />

Functionality under<br />

WinCC flexible/WinCC<br />

(TIA portal)<br />

see "Configuration overview" from page 2/3<br />

Applications/options See chapter 4: HMI software/SIMATIC WinCC<br />

flexible options and SIMATIC WinCC<br />

(TIA portal) options<br />

Task planner Yes Yes<br />

Help system Yes Yes<br />

Status/control<br />

With alarm logging<br />

system (incl. buffer and<br />

acknowledgment)<br />

with SIMATIC S7 with SIMATIC S7<br />

Number of messages 2000 2000<br />

Bit messages Yes Yes<br />

Analog messages Yes Yes<br />

Message buffer Ring buffer (n x 256<br />

entries), retentive,<br />

maintenance-free<br />

Ring buffer (n x 256<br />

entries), retentive,<br />

maintenance-free


■ Technical specifications (continued)<br />

6AV6 642-0DC01- 6AV6 642-0DA01-<br />

1AX1<br />

1AX1<br />

Product type<br />

designation<br />

Recipes<br />

OP 177B blue mode OP 177B color<br />

Recipes 100 100<br />

Data records per<br />

recipe<br />

200 200<br />

Entries per data<br />

record<br />

200 200<br />

Recipe memory 32 KB integrated 32 KB integrated<br />

Number of process<br />

images<br />

Flash, expandable Flash, expandable<br />

Process images 500 500<br />

Variables 1000 1 000<br />

Limit values Yes Yes<br />

Multiplexing<br />

Image elements<br />

Yes Yes<br />

Text objects 2,500 text elements 2,500 text elements<br />

Graphic object Bit maps, icons, icon Bit maps, icons, icon<br />

(full-screen), vector (full-screen), vector<br />

graphics<br />

graphics<br />

dynamic objects Diagrams, bar Diagrams, bar<br />

graphs, sliders, graphs, sliders,<br />

analog display, analog display,<br />

Lists<br />

invisible buttons invisible buttons<br />

Text lists 300 300<br />

Graphic list 100 100<br />

Libraries<br />

Security<br />

Yes Yes<br />

Number of user<br />

groups<br />

50 50<br />

Passwords exportable Yes Yes<br />

Number of user rights<br />

Data carrier support<br />

32 32<br />

<strong>PC</strong> card No No<br />

CF card No No<br />

Multimedia Card<br />

Recording<br />

Yes Yes<br />

Recording/Printing Alarms, report Alarms, report<br />

(shift report), (shift report), color<br />

hardcopy<br />

print, hardcopy<br />

Printer driver<br />

Fonts<br />

ESC/P2, <strong>PC</strong>L3/<strong>PC</strong>L6 ESC/P2, <strong>PC</strong>L3/<strong>PC</strong>L6<br />

Keyboard fonts US American US American<br />

(English)<br />

(English)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Product type<br />

designation<br />

Languages<br />

Configuration<br />

languages<br />

Operator panels<br />

Panels — 170 series<br />

D, GB, F, I, E, CHN<br />

"traditional", CHN<br />

"simplified", DK, FIN,<br />

GR, J, KP / ROK, NL,<br />

N, PL, P, RUS, S, CZ /<br />

SK, TR, H<br />

Character sets Tahoma, Courier New,<br />

WinCC flexible<br />

Standard, symbol<br />

languages,<br />

2 additional character<br />

sets can be loaded,<br />

all freely scalable<br />

Transfer<br />

(upload/download)<br />

Transfer of configuration<br />

MPI/PROFIBUS DP,<br />

serial, USB, by<br />

means of external<br />

storage medium,<br />

automatic transfer<br />

recognition<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC OP 177B<br />

D, GB, F, I, E, CHN<br />

"traditional", CHN<br />

"simplified", DK, FIN,<br />

GR, J, KP / ROK, NL,<br />

N, PL, P, RUS, S, CZ /<br />

SK, TR, H<br />

Tahoma, Courier New,<br />

WinCC flexible<br />

Standard, symbol<br />

languages,<br />

2 additional character<br />

sets can be loaded,<br />

all freely scalable<br />

MPI/PROFIBUS DP,<br />

serial, USB, Ethernet,<br />

by means of external<br />

storage medium,<br />

automatic transfer<br />

recognition<br />

Process coupling<br />

Connection to<br />

controller<br />

Expandability/openness<br />

see "System interfaces" from page 2/178<br />

Open Platform<br />

Program<br />

I/O<br />

Yes Yes<br />

I/O devices<br />

Dimensions and<br />

weight<br />

Dimensions<br />

Printer Printer<br />

Front of enclosure<br />

(W x H)<br />

243 mm x 212 mm 243 mm x 212 mm<br />

Mounting<br />

cutout/device depth<br />

(W x H)<br />

6AV6 642-0DC01- 6AV6 642-0DA01-<br />

1AX1<br />

1AX1<br />

OP 177B blue mode OP 177B color<br />

229 mm x 196 mm /<br />

45 mm device depth<br />

Weight<br />

Weight 1kg 1kg<br />

229 mm x 196 mm /<br />

45 mm device depth<br />

2/129<br />

2


2<br />

Operator panels<br />

Panels — 170 series<br />

SIMATIC OP 177B<br />

■ Ordering data Order No. Order No.<br />

SIMATIC OP 177B<br />

Documentation<br />

Operator panel with 5.7” <strong>ST</strong>N<br />

(to be ordered separately)<br />

display,<br />

Operating Instructions<br />

Blue mode (4 levels)<br />

Color (256 colors)<br />

incl. mounting accessories<br />

E<br />

E<br />

6AV6 642-0DC01-1AX1<br />

6AV6 642-0DA01-1AX1<br />

TP 177micro/TP 177A/TP 177B/<br />

OP 177B (WinCC flexible)<br />

German<br />

English<br />

6AV6 691-1DG01-0AA1<br />

6AV6 691-1DG01-0AB1<br />

OP 177B starter kit E 6AV6 551-2HA01-1AA0<br />

French 6AV6 691-1DG01-0AC1<br />

Consisting of:<br />

Italian 6AV6 691-1DG01-0AD1<br />

OP 177B with <strong>ST</strong>N display, color<br />

Spanish 6AV6 691-1DG01-0AE1<br />

Configuration software<br />

SIMATIC WinCC flexible<br />

Compact<br />

SIMATIC HMI Manual Collection<br />

(DVD), 5 languages (English,<br />

User Manual<br />

WinCC flexible<br />

Compact/Standard/Advanced<br />

German<br />

English<br />

6AV6 691-1AB01-3AA0<br />

6AV6 691-1AB01-3AB0<br />

French, German, Italian,<br />

Spanish)<br />

MPI cable (5 m) (for download<br />

and test purposes only),<br />

<strong>PC</strong>/PPI cable<br />

Configuration software<br />

With SIMATIC WinCC flexible<br />

Compact or SIMATIC WinCC<br />

Configuration set D<br />

see HMI software<br />

6AV6 621-0AA01-0AA0<br />

French<br />

Italian<br />

Spanish<br />

User Manual<br />

WinCC flexible Communication<br />

German<br />

English<br />

French<br />

Italian<br />

6AV6 691-1AB01-3AC0<br />

6AV6 691-1AB01-3AD0<br />

6AV6 691-1AB01-3AE0<br />

6AV6 691-1CA01-3AA0<br />

6AV6 691-1CA01-3AB0<br />

6AV6 691-1CA01-3AC0<br />

6AV6 691-1CA01-3AD0<br />

Consisting of:<br />

Spanish 6AV6 691-1CA01-3AE0<br />

SIMATIC WinCC flexible Compact<br />

engineering software, SIMATIC<br />

SIMATIC HMI Manual Collection B 6AV6 691-1SA01-0AX0<br />

HMI Manual Collection (DVD),<br />

5 languages (English, French,<br />

German, Italian and Spanish),<br />

<strong>PC</strong>/PPI cable Multimaster, MPI<br />

cable (5 m) (for download and<br />

test purposes only)<br />

Electronic documentation, on<br />

DVD<br />

5 languages (English, French,<br />

German, Italian and Spanish);<br />

contains: all currently available<br />

user manuals, manuals and<br />

communication manuals for<br />

SIMATIC HMI<br />

Accessories see HMI accessories<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical<br />

specifications.<br />

OP 177B<br />

2/130<br />

243<br />

212.5<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

194<br />

35.6<br />

42<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6.2<br />

G_<strong>ST</strong><strong>80</strong>_XX_00270<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-panels<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.


■ Overview<br />

Touch Panel with extensive functions for operator control and<br />

monitoring of machines and plants<br />

Content of message buffer is retained even when panel is<br />

disconnected, without batteries<br />

Pixel graphics TFT display with 256 colors and touchscreen<br />

Interfaces for communication with <strong>Siemens</strong> SIMATIC S7<br />

(e.g. MPI, PROFIBUS DP) are onboard<br />

Ethernet onboard<br />

Use of scripts and archives<br />

Drivers are also available for non-<strong>Siemens</strong> PLCs<br />

Installation-compatible with TP 270 6" and MP 270B 6"<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Panels — 270 series<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC TP 277 6"<br />

■ Benefits<br />

Reduction of service and commissioning costs through:<br />

- Backup/restoration via a process interface or optionally via a<br />

Multi Media Card<br />

- Remote downloading of the configuration with automatic<br />

transfer recognition via all device interfaces<br />

- Maintenance-free design (no battery) and long service life of<br />

the backlighting<br />

Maintenance-free message buffer<br />

Use of scripts and archives<br />

Can be used world-wide:<br />

- 32 offline languages can be configured (incl. Asian and<br />

Cyrillic character sets)<br />

- 16 online languages can be selected directly on the device<br />

Graphic library available with off-the-shelf picture objects<br />

Standard interfaces for increasing the flexibility:<br />

- External multimedia card, used for recipe data sets, archive<br />

and for backup of configuration/system data<br />

Integrated USB interface for connecting, for example,<br />

standard printers<br />

Simple engineering supported by comprehensive<br />

documentation on the SIMATIC HMI Manual Collection DVD<br />

Integral component of Totally Integrated Automation (TIA):<br />

Increases productivity, minimizes engineering outlay, reduces<br />

lifecycle costs<br />

■ Application<br />

Thanks to their practical functions and large user memory, the<br />

TP 277 6" Touch Panels can be used wherever operator control<br />

and monitoring of machines and plants is necessary on site –<br />

whether in production automation, process automation or<br />

building-services automation. The TP 277 6" offers a 256-color<br />

TFT display. The unit has an integrated PROFINET I/O interface<br />

for even greater flexibility. A further highlight is the non-volatile<br />

message buffer included as standard that stores messages<br />

permanently without battery backup.<br />

2/131<br />

2


2<br />

Operator panels<br />

Panels — 270 series<br />

SIMATIC TP 277 6"<br />

■ Design<br />

256-color TFT display<br />

CCFL 1) Long-life backlighting<br />

Analog resistive touch screen<br />

Numeric and alphanumeric on-screen keyboard<br />

Scripts and archives<br />

High performance thanks to RISC processor and 4 MB user<br />

memory, plus additional integrated recipe memory<br />

The data in the message buffer is retained even when the<br />

panel is disconnected from the supply, without battery backup<br />

MPI, PROFIBUS DP interfaces (up to 12 Mbaud) as well as<br />

USB 1.1 (max. 100 mA) onboard<br />

Ethernet (PROFINET I/O capable)<br />

Integrated USB interface<br />

Can be configured using SIMATIC WinCC flexible 2005<br />

Standard SP1<br />

Complete functionality for demanding tasks<br />

Comprehensive Reichert graphic library<br />

32 languages (e.g., Cyrillic, traditional Chinese, simplified<br />

Chinese) and online switching between up to 16 languages<br />

Multi Media Card slot, can be used for standard Multi Media<br />

Cards (for backing up archives and recipe data sets, the<br />

configuration and system data)<br />

Remote downloading of the configuration via all interfaces<br />

with automatic transfer recognition<br />

Options for SINUMERIK, Sm@rtAccess and Sm@rtService<br />

can be used<br />

Service-friendly thanks to maintenance-free design and long<br />

service life of the backlighting display<br />

1) Cold Cathode Fluorescence Lamps<br />

■ Function<br />

Permanent window and template concept for creating screen<br />

templates<br />

Input/output fields<br />

for visualizing and editing process parameters<br />

Configurable buttons<br />

with up to 16 functions are also used to directly trigger<br />

functions and actions<br />

Indicator light<br />

for machine and plant status indication<br />

Fixed texts<br />

for labeling function keys, process images and process<br />

values in any character size<br />

Help texts<br />

for process displays, messages, and variables<br />

Vector graphics, graphics<br />

can be used as icons instead of text for "labeling" buttons.<br />

They can also be used as full-screen background images.<br />

The configuration tool contains a library with extensive<br />

graphics and diverse objects. All editors with an OLE interface<br />

can be used as graphic editors (such as PaintShop, Designer<br />

or CorelDraw).<br />

Curve functions and bars<br />

are used for the display of dynamic values in graphic-based<br />

format<br />

2/132<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Dynamic positioning of objects and dynamic showing/hiding<br />

of objects<br />

Arithmetic functions, limit value monitoring<br />

for reliable process control with inputs and outputs<br />

Online language selection (16 selectable languages),<br />

incl. Asian and Cyrillic languages<br />

This also applies to language-specific graphics<br />

Timer<br />

for cyclic function processing<br />

Password protection (security)<br />

User management – Authentication by means of user ID and<br />

password plus privileges specific to user groups, which is an<br />

integral part of SIMATIC<br />

Signaling system;<br />

Freely definable message classes (acknowledgement<br />

behavior and display can be configured), administration of<br />

status, fault and system alarms. The message history is<br />

retained even if the device is switched off.<br />

Analog alarms (limit value messages) in addition to bit<br />

messages<br />

Visual Basic Script, flexibility thanks to the implementation of<br />

new functions including linking to variables (comparison<br />

operations, loops, etc.)<br />

Archiving of messages and process values (on MultiMedia<br />

card or network drives over Ethernet)<br />

- Various archive types: Circulating and sequence archive<br />

- Storage of archive data in standard Windows format (CSV)<br />

- Online evaluation of process value archives through trend<br />

curves<br />

- External processing using standard tools (MS Excel and<br />

MS Access) is possible<br />

Recipe management<br />

- With additional data storage (on ext. storage medium)<br />

- Online/offline processing on the panel<br />

- Storage of recipe data in standard Windows format (CSV)<br />

- External processing using standard tools such as Excel and<br />

Access is possible<br />

Multi Media Card slot<br />

for external standard data carrier, can be used for<br />

backup/restoration or for transporting recipe data records<br />

User-friendly maintenance and configuration thanks to:<br />

- Backup and restoration of the configuration, operating<br />

system, data records and firmware on a <strong>PC</strong> using ProSave<br />

- Option to download/upload the configuration via all device<br />

interfaces (with automatic transfer detection)<br />

- Individual contrast setting and calibration<br />

- Configuration simulation directly on the configuration<br />

computer<br />

Configuration<br />

The configuration is implemented using the innovative<br />

SIMATIC WinCC Comfort engineering tool. Projects generated<br />

using WinCC flexible can be easily migrated to WinCC.<br />

Additional options<br />

Sm@rtServer<br />

Remote control and monitoring of SIMATIC HMI systems<br />

based on TCP/IP networks


■ Technical specifications<br />

6AV6 643-0AA01-1AX0<br />

Product type designation TP 277 6"<br />

Display<br />

Size 5.7"<br />

Display type TFT, 256 colors<br />

Resolution (pixels)<br />

Resolution (WxH in pixel) 320 x 240<br />

Backlighting<br />

MTBF backlighting (at 25 °C) about 60,000 hours<br />

Control elements<br />

Control elements Touch screen<br />

Connection for<br />

USB / USB / USB<br />

mouse/keyboard/barcode reader<br />

Keyboard<br />

Numeric/alphabetical input Yes / Yes<br />

Touch operation<br />

Touch screen analog, resistive<br />

Supply voltage<br />

Input voltage<br />

permissible range +20.4 V to +28.8 V DC<br />

Supply voltage 24 V DC<br />

Processor<br />

Processor RISC 32-bit<br />

Memory<br />

Type Flash / RAM<br />

Usable memory for user data 4 MB usable memory for user<br />

data<br />

Time of day<br />

Clock<br />

Type Software clock, synchronizable,<br />

no battery backup<br />

Interfaces<br />

Interfaces 1 x RS422, 1 x RS485,<br />

1 x Ethernet (RJ45)<br />

USB port 1 x USB<br />

Multi Media Card slot 1 x Multi Media Card slot<br />

Industrial Ethernet<br />

Industrial Ethernet interface 1 x Ethernet (RJ45)<br />

Ambient conditions<br />

Operating temperature<br />

Operation 0 °C to +50 °C<br />

Storage/transport temperature<br />

Transport, storage -20 °C to +60 °C<br />

Relative humidity<br />

max. relative humidity <strong>80</strong> %<br />

Mounting position vertical<br />

Degree and class of protection<br />

Front IP65, NEMA 4x, (when installed)<br />

Rear IP20<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Panels — 270 series<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC TP 277 6"<br />

6AV6 643-0AA01-1AX0<br />

Product type designation TP 277 6"<br />

Standards, approvals, certificates<br />

Certifications CE, UL, NEMA 4x<br />

Operating systems<br />

Operating system Windows CE<br />

Configuration<br />

Configuration software<br />

Configuration tool see "Configuration overview" from<br />

page 2/3<br />

Functionality under WinCC<br />

flexible/WinCC (TIA portal)<br />

Applications/options See chapter 4: HMI<br />

software/SIMATIC WinCC flexible<br />

options and SIMATIC WinCC<br />

(TIA portal) options<br />

Number of Visual Basic Scripts 50<br />

Task planner Yes<br />

Help system Yes<br />

Status/control with SIMATIC S7<br />

With alarm logging system (incl.<br />

buffer and acknowledgment)<br />

Number of messages 4000<br />

Bit messages Yes<br />

Analog messages Yes<br />

Message buffer Ring buffer (n x 512 entries),<br />

retentive, maintenance-free<br />

Recipes<br />

Recipes 300<br />

Data records per recipe 500<br />

Entries per data record 1000<br />

Recipe memory 64 KB integrated Flash,<br />

expandable (using optional<br />

memory card)<br />

Number of process images<br />

Process images 500<br />

Variables 2048<br />

Limit values Yes<br />

Multiplexing Yes<br />

Image elements<br />

Text objects 10,000 text elements<br />

Graphic object Bit maps, icons, vector graphics<br />

dynamic objects Diagrams, bar graphs, sliders,<br />

analog display, invisible buttons<br />

Lists<br />

Text lists 500<br />

Graphic list 400<br />

Libraries Yes<br />

Archiving<br />

Number of archives per project 20<br />

Number of measuring points per 20<br />

project<br />

Number of entries per archive 10 000<br />

Memory location Multi Media Card<br />

2/133<br />

2


2<br />

Operator panels<br />

Panels — 270 series<br />

SIMATIC TP 277 6"<br />

■ Technical specifications (continued)<br />

6AV6 643-0AA01-1AX0<br />

Product type designation TP 277 6"<br />

Security<br />

Number of user groups 50<br />

Passwords exportable Yes<br />

Number of user rights 32<br />

Data carrier support<br />

Multimedia Card Yes<br />

Recording<br />

Recording/Printing Alarms, report (shift report),<br />

color print, hardcopy<br />

Fonts<br />

Keyboard fonts US American (English)<br />

Languages<br />

Configuration languages D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified", DK, FIN, GR, J,<br />

KP / ROK, NL, N, PL, P, RUS, S,<br />

CZ / SK, TR, H<br />

Character sets Tahoma, Arial, Courier New,<br />

WinCC flexible Standard, symbol<br />

languages, all freely scalable<br />

Transfer (upload/download)<br />

Transfer of configuration MPI/PROFIBUS DP, USB,<br />

Ethernet, automatic transfer<br />

recognition<br />

Process coupling<br />

Connection to controller see "System interfaces" from<br />

page 2/178<br />

Expandability/openness<br />

Open Platform Program Yes<br />

I/O<br />

I/O devices Printer, barcode reader<br />

Dimensions and weight<br />

Dimensions<br />

Front of enclosure (W x H) 212 mm x 156 mm<br />

Mounting cutout/device depth<br />

(W x H)<br />

Weight<br />

Weight 0.78 kg<br />

2/134<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

197 mm x 141 mm / 45 mm<br />

device depth<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Ordering data Order No.<br />

SIMATIC TP 277 6”<br />

Touch Panel with 5.7" TFT display,<br />

color (256 colors), incl. mounting<br />

accessories<br />

Configuration<br />

E 6AV6 643-0AA01-1AX0<br />

With SIMATIC WinCC flexible or<br />

SIMATIC WinCC<br />

see HMI Software<br />

Configuration set<br />

Consisting of:<br />

WinCC flexible Standard<br />

engineering software<br />

Documentation DVD,<br />

5 languages (English, French,<br />

German, Italian, Spanish)<br />

RS 232 cable (5 m)<br />

MPI cable, 5 m (for download<br />

and test purposes only)<br />

Applications/Options<br />

For configuration with<br />

WinCC flexible<br />

D 6AV6 622-0BA01-0AA0<br />

WinCC flexible /Sm@rtAccess see HMI Software<br />

WinCC flexible /Sm@rtService see HMI Software<br />

WinCC flexible /ProAgent<br />

Documentation<br />

(to be ordered separately)<br />

TP 277 / OP 277 Operating<br />

Instructions<br />

see HMI Software<br />

German 6AV6 691-1DH01-0AA0<br />

English 6AV6 691-1DH01-0AB0<br />

French 6AV6 691-1DH01-0AC0<br />

Italian 6AV6 691-1DH01-0AD0<br />

Spanish<br />

WinCC flexible<br />

Compact/Standard/Advanced<br />

User Manual<br />

6AV6 691-1DH01-0AE0<br />

German 6AV6 691-1AB01-3AA0<br />

English 6AV6 691-1AB01-3AB0<br />

French 6AV6 691-1AB01-3AC0<br />

Italian 6AV6 691-1AB01-3AD0<br />

Spanish<br />

WinCC flexible Communication<br />

User Manual<br />

6AV6 691-1AB01-3AE0<br />

German 6AV6 691-1CA01-3AA0<br />

English 6AV6 691-1CA01-3AB0<br />

French 6AV6 691-1CA01-3AC0<br />

Italian 6AV6 691-1CA01-3AD0<br />

Spanish 6AV6 691-1CA01-3AE0<br />

SIMATIC HMI Manual Collection B<br />

Electronic documentation, on<br />

DVD<br />

5 languages<br />

(English, French, German, Italian<br />

and Spanish); contains: all<br />

currently available user manuals,<br />

manuals and communication<br />

manuals for SIMATIC HMI<br />

6AV6 691-1SA01-0AX0<br />

Accessories see HMI Accessories<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU


■ Dimensional drawings<br />

All dimensions in mm. Tolerance ± 1 mm. Panel cutout see<br />

technical specifications.<br />

SIMATIC TP277<br />

212<br />

196<br />

156<br />

140<br />

22<br />

44<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6<br />

G_<strong>ST</strong><strong>80</strong>_XX_00308<br />

Operator panels<br />

Panels — 270 series<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC TP 277 6"<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-panels<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.<br />

2/135<br />

2


2<br />

Operator panels<br />

Panels — 270 series<br />

SIMATIC OP 277 6"<br />

■ Overview<br />

Operator Panel with extensive functions for operator control<br />

and monitoring of machines and plants<br />

Content of message buffer is retained even when panel is<br />

disconnected, without batteries<br />

Pixel graphics TFT display with 256 colors<br />

36 system keys, 24 freely-configurable and freely-inscribable<br />

function keys (18 with LEDs)<br />

Interfaces for communication with <strong>Siemens</strong> SIMATIC S7<br />

(e.g. MPI, PROFIBUS DP) are onboard<br />

Ethernet onboard<br />

Use of scripts and archives<br />

Drivers are also available for non-<strong>Siemens</strong> PLCs<br />

Installation-compatible with OP 270 6"<br />

2/136<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Reduction of service and commissioning costs through:<br />

- Backup/restoration via a process interface or optionally via a<br />

Multi Media Card<br />

- Remote downloading of the configuration with automatic<br />

transfer recognition via all device interfaces<br />

- Maintenance-free design (no battery) and long service life of<br />

the backlighting<br />

Maintenance-free message buffer<br />

Use of scripts and archives<br />

Can be used world-wide:<br />

- 32 offline languages can be configured (incl. Asian and<br />

Cyrillic character sets)<br />

- 16 online languages can be selected directly on the device<br />

Graphic library available with off-the-shelf picture objects<br />

Standard interfaces for increasing flexibility:<br />

- External multimedia card, used for recipe data sets, archive<br />

and for backup of configuration/system data<br />

Integrated USB interface for connecting, for example,<br />

standard printers<br />

Installation-compatible with OP 270 6"<br />

Simple engineering supported by comprehensive<br />

documentation on the SIMATIC HMI Manual Collection DVD<br />

Integral component of Totally Integrated Automation (TIA):<br />

Increases productivity, minimizes engineering outlay, reduces<br />

lifecycle costs<br />

■ Application<br />

Thanks to their practical functions and large user memory, the<br />

OP 277 6" Operator Panels can be used wherever operator<br />

control and monitoring of machines and plants is necessary on<br />

site – whether in production automation, process automation or<br />

building-services automation. The OP 277 6" offers a 256-color<br />

TFT display. The unit has an integrated PROFINET I/O interface<br />

for even greater flexibility. A further highlight is the non-volatile<br />

message buffer included as standard that stores messages<br />

permanently without battery backup.


■ Design<br />

256-color TFT display<br />

CCFL 1) Long-life backlighting<br />

Membrane keyboard with 36 system keys, 24 freelyconfigurable<br />

function keys (18 with LEDs)<br />

Rugged plastic housing with degree of protection IP65 (front)/<br />

IP20 (rear):<br />

High performance thanks to RISC processor and 4 MB user<br />

memory, plus additional integrated recipe memory<br />

The data in the message buffer is retained even when the<br />

panel is disconnected from the supply, without battery backup<br />

MPI, PROFIBUS DP interfaces (up to 12 Mbaud) as well as<br />

USB 1.1 (max. 100 mA) onboard<br />

Ethernet (PROFINET I/O capable)<br />

Integrated USB interface<br />

Can be configured using SIMATIC WinCC flexible 2005<br />

Standard SP1<br />

Complete functionality for demanding tasks<br />

Comprehensive Reichert graphic library<br />

32 languages (e.g. Cyrillic, traditional Chinese, simplified<br />

Chinese) and online switching between up to 16 languages<br />

Multi Media Card slot, can be used for standard Multi Media<br />

Cards (for backing up archives and recipe data sets, the<br />

configuration and system data)<br />

Remote downloading of the configuration via all interfaces<br />

with automatic transfer recognition<br />

Options for SINUMERIK, Sm@rtAccess and Sm@rtService<br />

can be used<br />

Service-friendly thanks to maintenance-free design and long<br />

service life of the backlighting display<br />

1) Cold Cathode Fluorescence Lamps<br />

■ Function<br />

Permanent window and template concept for creating screen<br />

templates<br />

Input/output fields<br />

for visualizing and editing process parameters<br />

Function keys<br />

are used for directly triggering functions and actions. Up to<br />

16 functions can be configured simultaneously on function<br />

keys. The function keys can be used directly as<br />

PROFIBUS DP input I/Os<br />

Indicator light<br />

for machine and plant status indication<br />

Fixed texts<br />

for labeling function keys, process images and process<br />

values in any character size<br />

Help texts<br />

for process displays, messages, and variables<br />

Vector graphics, graphics<br />

can be used as icons instead of text for "labeling" buttons.<br />

They can also be used as full-screen background images.<br />

The configuration tool contains a library with extensive<br />

graphics and diverse objects. All editors with an OLE interface<br />

can be used as graphics editors (such as PaintShop,<br />

Designer or CorelDraw).<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Panels — 270 series<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC OP 277 6"<br />

Curve functions and bars<br />

are used for the display of dynamic values in graphic-based<br />

format<br />

Dynamic positioning of objects and dynamic showing/hiding<br />

of objects<br />

Arithmetic functions, limit value monitoring<br />

for reliable process control with inputs and outputs<br />

Online language selection (16 selectable languages),<br />

incl. Asian and Cyrillic languages<br />

This also applies to language-specific graphics<br />

Timer<br />

for cyclic function processing<br />

Password protection (security)<br />

User management – Authentication by means of user ID and<br />

password plus privileges specific to user groups, which is an<br />

integral part of SIMATIC<br />

Signaling system;<br />

Freely definable message classes (acknowledgement<br />

behavior and display can be configured), administration of<br />

status, fault and system alarms. The message history is<br />

retained even if the device is switched off.<br />

Analog alarms (limit value messages) in addition to bit<br />

messages<br />

Visual Basic Script, flexibility thanks to the implementation of<br />

new functions including linking to variables (comparison<br />

operations, loops, etc.)<br />

Archiving of messages and process values<br />

(on MultiMedia card or network drives over Ethernet)<br />

- Various archive types: Circulating and sequence archive<br />

- Storage of archive data in standard Windows format (CSV)<br />

- Online evaluation of process value archives through trend<br />

curves<br />

- External processing using standard tools (MS Excel and<br />

MS Access) is possible<br />

Recipe management<br />

- With additional data storage (on ext. storage medium)<br />

- Online/offline processing on the panel<br />

- Storage of recipe data in standard Windows format (CSV)<br />

- External processing using standard tools such as Excel and<br />

Access is possible<br />

Multi Media Card (MMC) slot<br />

for external standard data carrier, can be used for<br />

backup/restoration or for transporting recipe data records<br />

User-friendly maintenance and configuration thanks to:<br />

- Backup and restoration of the configuration, operating<br />

system, data records and firmware on a <strong>PC</strong> using ProSave<br />

- Option to download/upload the configuration via all device<br />

interfaces (with automatic transfer detection)<br />

- Individual contrast setting and calibration<br />

- Configuration simulation directly on the configuration<br />

computer<br />

Configuration<br />

The configuration is implemented using the innovative<br />

SIMATIC WinCC Comfort engineering tool. Projects generated<br />

using WinCC flexible can be easily migrated to WinCC.<br />

Additional options<br />

Sm@rtServer<br />

Remote control and monitoring of SIMATIC HMI systems<br />

based on TCP/IP networks<br />

2/137<br />

2


2<br />

Operator panels<br />

Panels — 270 series<br />

SIMATIC OP 277 6"<br />

■ Technical specifications<br />

6AV6 643-0BA01-1AX0<br />

Product type designation OP 277 6"<br />

Display<br />

Size 5.7"<br />

Display type TFT, 256 colors<br />

Resolution (pixels)<br />

Resolution (WxH in pixel) 320 x 240<br />

Backlighting<br />

MTBF backlighting (at 25 °C) about 60,000 hours<br />

Control elements<br />

Control elements Membrane keyboard<br />

Function keys, programmable 24 function keys, 18 with LEDs<br />

Connection for<br />

USB / USB / USB<br />

mouse/keyboard/barcode reader<br />

Keyboard<br />

System keys 36<br />

Numeric/alphabetical input Yes / Yes (only English font can<br />

be displayed, only on screen)<br />

Supply voltage<br />

Input voltage<br />

permissible range +20.4 V to +28.8 V DC<br />

Supply voltage 24 V DC<br />

Processor<br />

Processor RISC 32-bit<br />

Memory<br />

Type Flash / RAM<br />

Usable memory for user data 4 MB usable memory for user<br />

data<br />

Type of output<br />

LED colors Green<br />

Time of day<br />

Clock<br />

Type Software clock, synchronizable,<br />

no battery backup<br />

Interfaces<br />

Interfaces 1 x RS422, 1 x RS485,<br />

1 x Ethernet (RJ45)<br />

USB port 1 x USB<br />

Multi Media Card slot 1 x Multi Media Card slot<br />

Industrial Ethernet<br />

Industrial Ethernet interface 1 x Ethernet (RJ45)<br />

Ambient conditions<br />

Operating temperature<br />

Operation 0 °C to +50 °C<br />

Storage/transport temperature<br />

Transport, storage -20 °C to +60 °C<br />

Relative humidity<br />

max. relative humidity <strong>80</strong> %<br />

Mounting position vertical<br />

Degree and class of protection<br />

Front IP65<br />

Rear IP20<br />

2/138<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV6 643-0BA01-1AX0<br />

Product type designation OP 277 6"<br />

Standards, approvals,<br />

certificates<br />

Certifications CE, UL<br />

Operating systems<br />

Operating system Windows CE<br />

Configuration<br />

Configuration software<br />

Configuration tool see "Configuration overview" from<br />

page 2/3<br />

Functionality under WinCC<br />

flexible/WinCC (TIA portal)<br />

Applications/options See chapter 4: HMI<br />

software/SIMATIC WinCC flexible<br />

options and SIMATIC WinCC<br />

(TIA portal) options<br />

Number of Visual Basic Scripts 50<br />

Task planner Yes<br />

Help system Yes<br />

Status/control with SIMATIC S7<br />

With alarm logging system<br />

(incl. buffer and acknowledgment)<br />

Number of messages 4000<br />

Bit messages Yes<br />

Analog messages Yes<br />

Message buffer Ring buffer (n x 512 entries),<br />

retentive, maintenance-free<br />

Recipes<br />

Recipes 300<br />

Data records per recipe 500<br />

Entries per data record 1000<br />

Recipe memory 64 KB integrated Flash,<br />

expandable<br />

Number of process images<br />

Process images 500<br />

Variables 2048<br />

Limit values Yes<br />

Multiplexing Yes<br />

Image elements<br />

Text objects 10,000 text elements<br />

Graphic object Bit maps, icons, vector graphics<br />

dynamic objects Diagrams, bar graphs, sliders,<br />

analog display, invisible buttons<br />

Lists<br />

Text lists 500<br />

Graphic list 400<br />

Libraries Yes<br />

Archiving<br />

Number of archives per project 20<br />

Number of measuring points per 20<br />

project<br />

Number of entries per archive 10 000<br />

Memory location Multi Media Card


■ Technical specifications (continued)<br />

6AV6 643-0BA01-1AX0<br />

Product type designation OP 277 6"<br />

Security<br />

Number of user groups 50<br />

Passwords exportable Yes<br />

Number of user rights 32<br />

Data carrier support<br />

Multimedia Card Yes<br />

Recording<br />

Recording/Printing Alarms, report (shift report),<br />

color print, hardcopy<br />

Fonts<br />

Keyboard fonts US American (English)<br />

Languages<br />

Configuration languages D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified", DK, FIN, GR, J,<br />

KP / ROK, NL, N, PL, P, RUS, S,<br />

CZ / SK, TR, H<br />

Character sets Tahoma, Arial, Courier New,<br />

WinCC flexible Standard, symbol<br />

languages, all freely scalable<br />

Transfer (upload/download)<br />

Transfer of configuration MPI/PROFIBUS DP, USB,<br />

Ethernet, automatic transfer<br />

recognition<br />

Process coupling<br />

Connection to controller see "System interfaces" from<br />

page 2/178<br />

Expandability/openness<br />

Open Platform Program Yes<br />

I/O<br />

I/O devices Printer, barcode reader<br />

Dimensions and weight<br />

Dimensions<br />

Front of enclosure (W x H) 308 mm x 204 mm<br />

Mounting cutout/device depth<br />

(W x H<br />

Weight<br />

Weight 1.19 kg<br />

281 mm x 177 mm / 59 mm<br />

device depth<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Panels — 270 series<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC OP 277 6"<br />

■ Ordering data Order No.<br />

SIMATIC OP 277 6"<br />

Operator Panel with 5.7" TFT<br />

display, color (265 colors), incl.<br />

mounting accessories<br />

Configuration<br />

E 6AV6 643-0BA01-1AX0<br />

With SIMATIC WinCC flexible or<br />

SIMATIC WinCC<br />

see HMI Software<br />

Configuration set<br />

Consisting of:<br />

WinCC flexible Standard<br />

engineering software<br />

Documentation DVD,<br />

5 languages (English, French,<br />

German, Italian, Spanish)<br />

RS 232 cable (5 m)<br />

MPI cable, 5 m (for download<br />

and test purposes only)<br />

Applications/Options<br />

For configuration with<br />

WinCC flexible<br />

D 6AV6 622-0BA01-0AA0<br />

WinCC flexible /Sm@rtAccess see HMI Software<br />

WinCC flexible /Sm@rtService see HMI Software<br />

WinCC flexible /ProAgent<br />

Documentation<br />

(to be ordered separately)<br />

TP 277 / OP 277 Operating<br />

Instructions<br />

see HMI Software<br />

German 6AV6 691-1DH01-0AA0<br />

English 6AV6 691-1DH01-0AB0<br />

French 6AV6 691-1DH01-0AC0<br />

Italian 6AV6 691-1DH01-0AD0<br />

Spanish<br />

WinCC flexible<br />

Compact/Standard/Advanced<br />

User Manual<br />

6AV6 691-1DH01-0AE0<br />

German 6AV6 691-1AB01-3AA0<br />

English 6AV6 691-1AB01-3AB0<br />

French 6AV6 691-1AB01-3AC0<br />

Italian 6AV6 691-1AB01-3AD0<br />

Spanish<br />

WinCC flexible Communication<br />

User Manual<br />

6AV6 691-1AB01-3AE0<br />

German 6AV6 691-1CA01-3AA0<br />

English 6AV6 691-1CA01-3AB0<br />

French 6AV6 691-1CA01-3AC0<br />

Italian 6AV6 691-1CA01-3AD0<br />

Spanish 6AV6 691-1CA01-3AE0<br />

SIMATIC HMI Manual Collection B<br />

Electronic documentation, on<br />

DVD<br />

5 languages<br />

(English, French, German,<br />

Italian and Spanish); contains:<br />

all currently available user<br />

manuals, manuals and communication<br />

manuals for<br />

SIMATIC HMI<br />

6AV6 691-1SA01-0AX0<br />

Accessories see HMI Accessories<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

2/139<br />

2


2<br />

Operator panels<br />

Panels — 270 series<br />

SIMATIC OP 277 6"<br />

■ Dimensional drawings<br />

All dimensions in mm. Tolerance ± 1 mm. Panel cutout see<br />

technical specifications.<br />

SIMATIC OP 277<br />

2/140<br />

308<br />

2<strong>80</strong><br />

197<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

204<br />

176<br />

57 6<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00307<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-panels<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.


■ Overview<br />

Operator panel for operation and monitoring of machines and<br />

systems<br />

Graphics in a new dimension: small and smart<br />

Pixel-graphics 3" LCD, monochrome<br />

8 system keys, 4 freely configurable function keys<br />

All interfaces (e.g. MPI, PROFIBUS DP) are onboard<br />

SIPLUS OP 73 is the successor of the Operator Panel OP3<br />

Note:<br />

SIPLUS extreme products are based on <strong>Siemens</strong> Industry<br />

standard products. The contents listed here were taken from the<br />

respective standard products. SIPLUS extreme-specific information<br />

was added.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

SIPLUS Panels for 70 series<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIPLUS HMI OP 73<br />

SIPLUS HMI OP 73<br />

Order No. 6AG1 641-0AA11-4AX0<br />

Order No. based on 6AV6 641-0AA11-0AX0<br />

Ambient temperature range 0 ... +50 °C<br />

Conformal coating Coating of the printed circuit<br />

boards and the electronic<br />

components<br />

Technical data The technical data of the<br />

standard product applies except<br />

for the ambient conditions.<br />

Ambient conditions<br />

Relative humidity 5 ... 100 %<br />

Condensation permissible<br />

Biologically active substances Conformity with EN 60721-3-3,<br />

Class 3B2 mold and fungal<br />

spores (except fauna)<br />

Chemically active substances Conformity with EN 60721-3-3,<br />

Class 3C4 incl. salt mist and<br />

ISA–S71.04 severity level G1; G2;<br />

1) 2)<br />

G3; GX<br />

Mechanically active substances Conformity with EN 60721-3-3,<br />

Class 3S4 including conductive<br />

sand, dust 2)<br />

Air pressure (depending on the 10<strong>80</strong> ... 795 hPa<br />

highest positive temperature range (-1000 ... +2000 m)<br />

specified)<br />

see ambient temperature range<br />

795 ... 658 hPa<br />

(+2000 ... +3500 m)<br />

derating 10 K<br />

658 ... 540 hPa<br />

(+3500 ... +5000 m)<br />

derating 20 K<br />

1) ISA-S71.04 severity level GX: Long-term load:<br />

SO2


2<br />

Operator panels<br />

SIPLUS Panels for 70 series<br />

SIPLUS HMI OP 77B<br />

■ Overview<br />

Compact operator panel for operator control and monitoring of<br />

machines and systems<br />

Graphics in a new dimension: small and smart<br />

Pixel-graphics 4.5" LCD, monochrome<br />

23 system keys, 8 freely-configurable and freely-inscribable<br />

function keys (4 with LEDs)<br />

All interfaces (e.g. MPI, PROFIBUS DP) are onboard<br />

Non-<strong>Siemens</strong> PLCs can be connected using easy-to-use<br />

drivers<br />

Together with OP 77A, successor to the successful OP 7<br />

Note:<br />

SIPLUS extreme products are based on <strong>Siemens</strong> Industry<br />

standard products. The contents listed here were taken from the<br />

respective standard products. SIPLUS extreme-specific information<br />

was added.<br />

2/142<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIPLUS HMI OP 77B<br />

Order No. 6AG1 641-0CA01-4AX1<br />

Order No. based on 6AV6 641-0CA01-0AX1<br />

Ambient temperature range 0 ... +50 °C<br />

Conformal coating Coating of the printed circuit<br />

boards and the electronic<br />

components<br />

Technical data The technical data of the<br />

standard product applies except<br />

for the ambient conditions.<br />

Ambient conditions<br />

Relative humidity 5 ... 100 %<br />

Condensation permissible<br />

Biologically active substances Conformity with EN 60721-3-3,<br />

Class 3B2 mold and fungal<br />

spores (except fauna)<br />

Chemically active substances Conformity with EN 60721-3-3,<br />

Class 3C4 incl. salt mist and<br />

ISA–S71.04 severity level G1; G2;<br />

1) 2)<br />

G3; GX<br />

Mechanically active substances Conformity with EN 60721-3-3,<br />

Class 3S4 including conductive<br />

sand, dust 2)<br />

Air pressure (depending on the 10<strong>80</strong> ... 795 hPa<br />

highest positive temperature range (-1000 ... +2000 m)<br />

specified)<br />

see ambient temperature range<br />

795 ... 658 hPa<br />

(+2000 ... +3500 m)<br />

derating 10 K<br />

658 ... 540 hPa<br />

(+3500 ... +5000 m)<br />

derating 20 K<br />

1) ISA-S71.04 severity level GX: Long-term load:<br />

SO2


■ Overview<br />

Operator panels<br />

SIPLUS Panels for 170 series<br />

SIPLUS HMI TP 177B<br />

All interfaces for communication with <strong>Siemens</strong> SIMATIC S7<br />

(e.g. MPI, PROFIBUS DP) are onboard<br />

PROFINET interface already on board in color version<br />

Drivers are also available for controllers from other<br />

manufacturers<br />

Data in the message buffer is retained even if the panel is<br />

switched off, without battery<br />

The 4" version features 4 additional function keys for optimized<br />

operator control efficiency<br />

The SIMATIC TP 177B 6" is the innovative successor to the<br />

TP 170B Touch Panel<br />

The TP 177B PN/DP is also available with a stainless steel front<br />

(EN 1672-2). The stainless steel front is also appropriate for<br />

increased demands such as in the food and beverages<br />

industry.<br />

Touch Panel with extensive functions for operator control and<br />

monitoring of machines and plants<br />

Note:<br />

SIPLUS extreme products are based on <strong>Siemens</strong> Industry<br />

standard products. The contents listed here were taken from the<br />

Pixel-graphic display with analog touch screen<br />

respective standard products. SIPLUS extreme-specific infor-<br />

- 4.3" TFT widescreen color display or<br />

- 5.7" <strong>ST</strong>N blue mode/color display<br />

mation was added.<br />

SIPLUS HMI TP 177B COLOR PN/DP TP 177B MONO DP TP 177B 4" COLOR PN/DP<br />

Order No. 6AG1 642-0BA01-4AX1 6AG1 642-0BC01-4AX1 6AG1 642-0BD01-2AX0<br />

Order No. based on 6AV6 642-0BA01-1AX1 6AV6 642-0BC01-1AX1 6AV6 642-0BD01-3AX0<br />

Ambient temperature range 0 ... +50 °C 0 ... +50 °C -10 ... +60 °C<br />

Conformal coating Coating of the printed circuit boards and the electronic components<br />

Technical specifications<br />

Ambient conditions<br />

The technical data of the standard product applies except for the ambient conditions.<br />

Relative humidity 5 ... 100 %<br />

Condensation permissible<br />

Biologically active substances Conformity with EN 60721-3-3, Class 3B2 mold and fungal spores (except fauna)<br />

Chemically active substances Conformity with EN 60721-3-3, Class 3C4 incl. salt mist and ISA–S71.04 severity level G1; G2; G3; GX 1) 2)<br />

Mechanically active substances Conformity with EN 60721-3-3, Class 3S4 including conductive sand, dust 2)<br />

Air pressure (depending on the 10<strong>80</strong> ... 795 hPa (-1000 ... +2000 m) see ambient temperature range<br />

highest positive temperature range<br />

specified)<br />

795 ... 658 hPa (+2000 ... +3500 m) derating 10 K<br />

658 ... 540 hPa (+3500 ... +5000 m) derating 20 K<br />

1) ISA-S71.04 severity level GX: Long-term load: SO 2 < 4.8 ppm H 2 S < 9.9 ppm; Cl < 0.2 ppm; HCl < 0.66 ppm; HF < 0.12 ppm; NH < 49 ppm;<br />

O 3 < 0.1 ppm; NOX < 5.2 ppm<br />

Threshold/ limit value (max. 30 min/d): SO 2 < 14.8 ppm; H2S < 49.7 ppm; Cl < 1.0 ppm; HCl < 3.3 ppm; HF < 2.4 ppm; NH < 247 ppm;<br />

O 3 < 1.0 ppm; NOX < 10.4 ppm<br />

2) The supplied plug covers must remain in place over the unused interface when operated in atmospheres containing corrosive gases<br />

For further technical documentation on SIPLUS, see:<br />

www.siemens.com/siplus-extreme<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Ordering data Order No. Order No.<br />

SIPLUS HMI TP 177B<br />

Touch Panel with<br />

Accessories see SIMATIC TP 177B<br />

4.3" TFT widescreen color<br />

display (256 colors)<br />

E 6AG1 642-0BD01-2AX0<br />

5.7" <strong>ST</strong>N blue mode display<br />

(4 levels)<br />

E 6AG1 642-0BC01-4AX1<br />

5.7" <strong>ST</strong>N color display<br />

(256 colors)<br />

including mounting hardware<br />

E 6AG1 642-0BA01-4AX1<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/143<br />

2


2<br />

Operator panels<br />

SIPLUS Panels for 170 series<br />

SIPLUS HMI OP 177B<br />

■ Overview<br />

2/144<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Touch/keys panel with extensive functionality for operation<br />

and monitoring of machines and systems<br />

The buffer content remains even when the panels are<br />

switched off and no battery is present<br />

Pixel graphics <strong>ST</strong>N display blue mode/color with analog touch<br />

screen and 32 additional function keys<br />

Interfaces for communication with <strong>Siemens</strong> SIMATIC S7<br />

(e.g. MPI, PROFIBUS DP) onboard<br />

Ethernet in the color version onboard<br />

Drivers are also available for controllers from other manufacturers<br />

Installation compatible with OP17<br />

Note:<br />

SIPLUS extreme products are based on <strong>Siemens</strong> Industry<br />

standard products. The contents listed here were taken from the<br />

respective standard products. SIPLUS extreme-specific information<br />

was added.<br />

SIPLUS HMI OP 177B color PN/DP OP 177B COLOR PN/DP OP 177B MONO DP<br />

Order No. 6AG1 642-0DA01-4AX1 6AG1 642-0DC01-4AX1<br />

Order No. based on 6AV6 642-0DA01-1AX1 6AV6 642-0DC01-1AX1<br />

Ambient temperature range 0 ... +50 °C<br />

Conformal coating Coating of the printed circuit boards and the electronic components<br />

Technical specifications<br />

Ambient conditions<br />

The technical data of the standard product applies except for the ambient conditions.<br />

Relative humidity 5...100%<br />

Condensation permissible<br />

Biologically active substances Conformity with EN 60721-3-3, Class 3B2 mold and fungal spores (except fauna)<br />

Chemically active substances Conformity with EN 60721-3-3, Class 3C4 incl. salt mist and ISA-S71.04 severity level G1; G2;<br />

G3; GX 1) 2)<br />

Mechanically active substances Conformity with EN 60721-3-3, Class 3S4 including conductive sand, dust 2)<br />

Air pressure (depending on the highest positive 10<strong>80</strong> ... 795 hPa (-1000 ... +2000 m)<br />

temperature range specified)<br />

see ambient temperature range<br />

795 ... 658 hPa (+2000 ... +3500 m)<br />

derating 10 K<br />

658 ... 540 hPa (+3500 ... +5000 m)<br />

derating 20 K<br />

1) ISA-S71.04 severity level GX: Long-term load: SO 2 < 4.8 ppm; H 2S < 9.9 ppm; Cl < 0.2 ppm; HCl < 0.66 ppm; HF < 0.12 ppm;<br />

NH < 49 ppm; O 3 < 0.1 ppm; NO x < 5.2 ppm<br />

Threshold/ limit value (max. 30 min/d): SO 2 < 17.8 ppm; H 2S < 49.7 ppm; Cl < 1.0 ppm; HCl < 3.3 ppm; HF < 2.4 ppm; NH < 247 ppm;<br />

O 3 < 1.0 ppm; NOX < 10.4 ppm<br />

2) The supplied plug covers must remain in place over the unused interface when operated in atmospheres containing corrosive gases<br />

For further technical documentation on SIPLUS, see:<br />

www.siemens.com/siplus-extreme<br />

■ Ordering data Order No. Order No.<br />

SIPLUS HMI OP 177B color<br />

PN/DP<br />

E 6AG1 642-0DA01-4AX1<br />

Accessories see SIMATIC HMI OP 177B<br />

(medial exposure)<br />

Operator Panel with 5.7" color<br />

<strong>ST</strong>N display, incl. mounting<br />

accessories<br />

SIPLUS HMI OP 177B MONO DP E 6AG1 642-0DC01-4AX1<br />

(medial exposure)<br />

Operator Panel with 5.7" blue<br />

mode <strong>ST</strong>N display, incl.<br />

mounting accessories<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Overview<br />

Operator panels<br />

SIPLUS Panels for 270 series<br />

SIPLUS HMI TP 277 6"<br />

Touch Panel with extensive functions for operator control and<br />

monitoring of machines and plants<br />

The buffer content remains even when the panels are off and<br />

no battery is present<br />

Pixel graphics TFT display with 256 colors and touch screen<br />

Onboard interfaces for communication with <strong>Siemens</strong> SIMATIC<br />

S7 (e.g. MPI, PROFIBUS DP)<br />

Ethernet onboard<br />

Use of scripts and archives<br />

Drivers are also available for controllers from other<br />

manufacturers<br />

Installation-compatible with TP 270 6" and MP 270B 6"<br />

Note:<br />

SIPLUS extreme products are based on <strong>Siemens</strong> Industry<br />

standard products. The contents listed here were taken from the<br />

respective standard products. SIPLUS extreme-specific information<br />

was added.<br />

SIPLUS HMI TP277 6"<br />

Order No. 6AG1 643-0AA01-4AX0<br />

Order No. based on 6AV6 643-0AA01-1AX0<br />

Ambient temperature range 0 ... +50 °C<br />

Conformal coating Coating of the printed circuit boards and the electronic components<br />

Technical data<br />

Ambient conditions<br />

The technical data of the standard product applies except for the ambient conditions.<br />

Relative humidity 5...100%<br />

Condensation permissible<br />

Biologically active substances Conformity with EN 60721-3-3, Class 3B2 mold and fungal spores (except fauna)<br />

Chemically active substances Conformity with EN 60721-3-3, Class 3C4 incl. salt mist and ISA–S71.04 severity level G1; G2;<br />

G3; GX 1) 2)<br />

Mechanically active substances Conformity with EN 60721-3-3, Class 3S4 including conductive sand, dust 2)<br />

Air pressure (depending on the highest positive 10<strong>80</strong> ... 795 hPa (-1000 ... +2000 m) see ambient temperature range<br />

temperature range specified)<br />

795 ... 658 hPa (+2000 ... +3500 m) derating 10 K<br />

658 ... 540 hPa (+3500 ... +5000 m) derating 20 K<br />

1) ISA-S71.04 severity level GX: Long-term load: SO 2 < 4.8 ppm; H 2S < 9.9 ppm; Cl < 0.2 ppm; HCl < 0.66 ppm; HF < 0.12 ppm;<br />

NH < 49 ppm; O 3 < 0.1 ppm; NOX < 5.2 ppm<br />

Limit value (max. 30 min/d): SO 2 < 17.8 ppm; H 2S < 49.7 ppm; Cl < 1.0 ppm; HCl < 3.3 ppm; HF < 2.4 ppm; NH < 247 ppm;<br />

O 3


2<br />

Operator panels<br />

Multi Panels — 170 series<br />

SIMATIC MP 177<br />

■ Overview<br />

Like operator panels, Multi Panels (MP) are used for local<br />

machine operation and monitoring<br />

Message buffer contents and residual WinAC MP data are<br />

retained even when panel is disconnected, without batteries<br />

PLC functionality can be integrated directly into the MP 177<br />

platform as an option<br />

The multi panel can be expanded with the options<br />

Sm@rtService and Sm@rtAccess<br />

Pixel-graphics 5.7" TFT display, color (64k colors)<br />

All interfaces, e.g. MPI, PROFIBUS DP, USB, PROFINET<br />

(Ethernet TCP/IP), are onboard<br />

The MP 177 6" Touch can also be delivered as a package,<br />

complete with a WinAC MP 177.<br />

2/146<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Integral component of Totally Integrated Automation (TIA):<br />

Increased productivity, minimum engineering overhead,<br />

reduction in life-cycle costs<br />

Modular expansion with options such as:<br />

- WinAC MP 177/software PLC (PLC programs compatible to<br />

the greatest possible extent)<br />

- WinCC flexible /Sm@rtAccess for communication between<br />

different SIMATIC HMI systems<br />

- WinCC flexible /Sm@rtService for remote maintenance and<br />

servicing of machines/plants via the intranet/Internet<br />

Reduction of service and commissioning costs through:<br />

- Backup/Restore via Ethernet (TCP/IP), MPI, PROFIBUS DP<br />

or optionally via standard MMC/SD card or USB stick<br />

- HMI, PLC, system data including licenses for a standard<br />

storage medium, simplest manageability<br />

- Remote download/upload of the configuration and firmware<br />

(Remote = automatic transfer recognition)<br />

- Specific drivers for non-<strong>Siemens</strong> PLCs can be reloaded<br />

- Long service life of the backlighting<br />

Can be used worldwide:<br />

- 32 languages can be configured (incl. Asian and Cyrillic<br />

character sets)<br />

Standard hardware and software interfaces for increasing<br />

flexibility:<br />

- SD/MultiMediaCard slot for memory expansions,<br />

backup/restore or additional interfaces<br />

- Ethernet (TCP/IP) for central data and project management<br />

control link possible to SIMATIC S7<br />

- A cross cable or normal LAN cable can be used for the pointto-point<br />

connection<br />

- Standard Windows storage formats (CSV) for recipes permit<br />

further processing with standard tools (e.g. Microsoft Excel)<br />

■ Application<br />

Multi panels are used in the most diverse industries and applications.<br />

Their usage can be expanded by means of options, e.g.<br />

integration of the PLC functionality by means of WinAC MP 177.<br />

The software PLC is customized for small and mid-sized applications.<br />

The diskless and fanless design enables implementation in<br />

areas where high vibration or dust load limits the operation of a<br />

<strong>PC</strong>. Maintenance-free data management ensures backup of all<br />

important data even when disconnected.


■ Design<br />

Compact design with low mounting depth<br />

- Display resolution (320 x 240 pixels) with 64k colors,<br />

dimmable<br />

The front is resistant to various oils, greases and standard<br />

detergents<br />

Degree of protection IP65/NEMA 4x/NEMA 12 (front) or IP20<br />

(rear)<br />

All connections are pluggable<br />

Interfaces:<br />

- RS 485/RS 422 interface for process connections<br />

(PPI, MPI, PROFIBUS DP up to 12 Mbit/s)<br />

- USB interface for memory, mouse, keyboard, printer, and<br />

downloading/uploading of the configuration<br />

- Ethernet (TCP/IP) for data exchange with a higher-level <strong>PC</strong><br />

- Slot for SD Card/Multi Media Card<br />

■ Function<br />

Display and modification of process parameters<br />

Process display:<br />

- Vector graphics (various line and surface objects)<br />

- Dynamic positioning and dynamic showing/hiding of objects<br />

- Pixel-graphic displays and bar displays<br />

- Curve graphics with paging and zoom functions for access<br />

to the history and for flexible selection of the presentation<br />

time; reading ruler for determining the current values and<br />

displaying them in a table<br />

- Extensive symbol libraries (SIMATIC HMI Symbol Library)<br />

- Screen objects: Slider, analog instrument, date and time<br />

display<br />

- Timer for cyclical function processing<br />

Multiplex function for variables<br />

Signaling system<br />

- Bit messages and analog messages (limit value messages)<br />

- Message history for status and fault messages<br />

- Message buffer stores even when panel is disconnected,<br />

without batteries<br />

- Message window and message line<br />

Message log and shift log<br />

Print functions (see "Recommended printers")<br />

Fully developed language switching for texts and graphics<br />

including Asian and Cyrillic character sets<br />

Recipe management<br />

- Internal and/or external data storage<br />

- Export of recipe data in standard Windows format (CSV)<br />

TIA Runtime Functionalities<br />

- A collective data management for PLC and HMI of data, bit<br />

memories, inputs/outputs, etc.<br />

- Collective usage of symbolic object names<br />

- Report system errors with Alarm S to SIMATIC S7 and<br />

SIMOTION with a mouse click<br />

- <strong>ST</strong>ATUS/FORCE-VAR in conjunction with SIMATIC S7<br />

Password system<br />

- Authentication and assignment of user rights with user ID<br />

and password<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Multi Panels — 170 series<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC MP 177<br />

Configuration<br />

The configuration is implemented using the<br />

SIMATIC WinCC Comfort engineering software.<br />

A Getting Started video is available at:<br />

http://support.automation.siemens.com/WW/view/en/32010673<br />

free of charge.<br />

Applications/Options<br />

WinAC MP software PLC for Multi Panels<br />

- WinAC MP 177 option for MP 177 (software PLC similar to the<br />

performance class of CPU 314)<br />

- The I/O devices can be connected via PROFIBUS DP<br />

Service functions can be used with the "Sm@rtServer" option<br />

- E-mail generation and web server can be used<br />

- Remote control of the SIMATIC HMI panel using a standard<br />

Internet Explorer<br />

Client/server functions can be used with the "Sm@rtServer"<br />

option<br />

- Remote operation and monitoring from one SIMATIC HMI<br />

system to another SIMATIC HMI system<br />

- Plant-wide polling of information<br />

- Central archiving of process data<br />

■ Integration<br />

The MP 177 6" Touch is multi-protocol-capable and can be<br />

connected to some extent simultaneously to:<br />

SIMATIC S7-200/-300/-400<br />

SIMATIC WinAC RTX/Slot PLC<br />

SIMATIC WinAC MP<br />

SIMOTION<br />

SINUMERIK<br />

(optionally with "SINUMERIK HMI copy license WinCC flexible<br />

CE"; the "SINUMERIK HMI engineering package WinCC flexible"<br />

is additionally required for configuration; for further information<br />

see <strong>Catalog</strong> NC 60)<br />

PLCs from other manufacturers<br />

- Allen Bradley<br />

- Mitsubishi<br />

- LG GLOFA GM<br />

- Modicon<br />

- GE-Fanuc<br />

-Omron<br />

- Telemecanique Uni-Telway<br />

Over Ethernet (TCP/IP) to a higher-level <strong>PC</strong>, with enabled<br />

network printer<br />

Note:<br />

Further information can be found under "System interfaces".<br />

2/147<br />

2


2<br />

Operator panels<br />

Multi Panels — 170 series<br />

SIMATIC MP 177<br />

■ Technical specifications<br />

6AV6 642-0EA01-3AX0<br />

Product type designation 6" Touch<br />

Display<br />

Size 5.7"<br />

Display type TFT, 65536 colors<br />

Resolution (pixels)<br />

Resolution (WxH in pixel) 320 x 240<br />

Backlighting<br />

MTBF backlighting (at 25 °C) about 50,000 hours<br />

Control elements<br />

Control elements Touch screen<br />

Connection for<br />

USB / USB / USB<br />

mouse/keyboard/barcode reader<br />

Keyboard<br />

Numeric/alphabetical input Yes (on-screen keyboard) / Yes<br />

(on-screen keyboard)<br />

Touch operation<br />

Touch screen analog, resistive<br />

Supply voltage<br />

Input voltage<br />

permissible range +19.2 V to +28.8 V DC<br />

Supply voltage 24 V DC<br />

Processor<br />

Processor RISC 32-bit, 520 MHz<br />

Memory<br />

Type Flash / RAM<br />

Usable memory for user data 2 MB usable memory for user<br />

data<br />

Time of day<br />

Clock<br />

Type Hardware clock, battery backup,<br />

synchronizable<br />

Interfaces<br />

USB port 1 x USB<br />

Multimedia card combined<br />

Industrial Ethernet<br />

Industrial Ethernet interface 1 x Ethernet (RJ45)<br />

Protocols<br />

Protocols (terminal link)<br />

Sm@rtAccess Yes<br />

EMC<br />

Emission of radio interference acc.<br />

to EN 55 011<br />

Emission of radio interferences<br />

acc. to EN 55 011 (limit class A)<br />

2/148<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Yes; EN 61000-6-4, interference<br />

emission: Intended for use in<br />

industrial areas.<br />

Ambient conditions<br />

Operating temperature<br />

Operation 0 °C to +50 °C<br />

Storage/transport temperature<br />

Transport, storage -20 °C to +70 °C<br />

Relative humidity<br />

max. relative humidity 90 %<br />

Mounting position vertical<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV6 642-0EA01-3AX0<br />

Product type designation 6" Touch<br />

Degree and class of protection<br />

Front IP65, NEMA 4, NEMA 4x, NEMA<br />

12 (when installed)<br />

Rear IP20<br />

Standards, approvals, certificates<br />

Certifications CE, GL, FM Class I Div. 2, cULus,<br />

C-TICK, NEMA 4, NEMA 4x,<br />

NEMA 12<br />

Operating systems<br />

Operating system Windows CE (Version 5)<br />

Configuration<br />

Configuration software<br />

Configuration tool see "Configuration overview" from<br />

page 2/3<br />

Functionality under<br />

WinCC flexible/WinCC<br />

(TIA portal)<br />

Applications/options See chapter 4: HMI<br />

software/SIMATIC WinCC flexible<br />

options and SIMATIC WinCC<br />

(TIA portal) option<br />

Task planner Yes<br />

Help system Yes<br />

Status/control with SIMATIC S7<br />

With alarm logging system<br />

(incl. buffer and acknowledgment)<br />

Number of messages 2000<br />

Bit messages Yes<br />

Analog messages Yes<br />

Message buffer Ring buffer (n x 256 entries),<br />

retentive, maintenance-free<br />

Recipes<br />

Recipes 100<br />

Data records per recipe 200<br />

Entries per data record 200<br />

Recipe memory 32 KB integrated Flash,<br />

expandable<br />

Number of process images<br />

Process images 500<br />

Variables 1000<br />

Limit values Yes<br />

Multiplexing Yes<br />

Image elements<br />

Text objects 2,500 text elements<br />

Graphic object Bit maps, icons, vector graphics<br />

dynamic objects Diagrams, bar graphs, sliders,<br />

analog display, invisible buttons<br />

Lists<br />

Text lists 300<br />

Graphic list 100<br />

Libraries Yes<br />

Security<br />

Number of user groups 50<br />

Passwords exportable Yes<br />

Number of user rights 32<br />

Data carrier support<br />

Multimedia Card Yes


■ Technical specifications (continued)<br />

6AV6 642-0EA01-3AX0<br />

Product type designation 6" Touch<br />

Recording<br />

Recording/Printing Alarms, report (shift report),<br />

color print, hardcopy<br />

Printer driver ESC/P2, <strong>PC</strong>L3/<strong>PC</strong>L6<br />

Fonts<br />

Keyboard fonts US American (English)<br />

Languages<br />

Configuration languages D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified", DK, FIN, GR, J,<br />

KP / ROK, NL, N, PL, P, RUS, S,<br />

CZ / SK, TR, H<br />

Character sets Tahoma, Courier New, WinCC<br />

flexible Standard, symbol<br />

languages, all freely scalable<br />

Transfer (upload/download)<br />

Transfer of configuration MPI/PROFIBUS DP, serial, USB,<br />

Ethernet, automatic transfer<br />

recognition<br />

Process coupling<br />

Connection to controller see "System interfaces" from<br />

page 2/178<br />

I/O<br />

I/O devices Printer, barcode reader<br />

Dimensions and weight<br />

Dimensions<br />

Front of enclosure (W x H) 212 mm x 156 mm<br />

Mounting cutout/device depth<br />

(W x H)<br />

198 mm x 142 mm / 45 mm<br />

device depth<br />

Weight<br />

Weight 0.85 kg; max.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Ordering data Order No.<br />

Operator panels<br />

Multi Panels — 170 series<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC MP 177<br />

SIMATIC HMI MP 177 6" Touch E 6AV6 642-0EA01-3AX0<br />

SIMATIC MP 177 6" Touch<br />

package<br />

Consisting of:<br />

SIMATIC MP 177 6" Touch<br />

SIMATIC WinAC MP<br />

E 6AV6 652-2JC01-2AA0<br />

1) Can only be used for license handling<br />

2) WinCC flexible 2008 SP1 required<br />

2)<br />

Single License for WinAC MP<br />

177 on USB flash drive1) Electronic documentation for<br />

WinAC MP<br />

Standard SD card 256 MB<br />

(empty)<br />

Starter package 613 WinAC MP E<br />

Consisting of:<br />

SIMATIC MP 177 6" Touch with<br />

mounting accessories,<br />

mounting seal, power supply<br />

connector<br />

SIMATIC WinAC MP including<br />

single license on a USB flash<br />

drive and electronic documentation<br />

SD card 256 KB (empty)<br />

ET200M incl.<br />

- 16 DI, 16 DO, 8 AI, 2 AO<br />

- FM350-2 8-channel counter<br />

- Front connector, bus<br />

connector, and mounting rail<br />

6AV6 652-2JD01-2AA0<br />

Starter package<br />

635T WinAC MP<br />

Consisting of:<br />

SIMATIC MP 177 6" Touch with<br />

mounting accessories,<br />

mounting seal, power supply<br />

connector<br />

SIMATIC WinAC MP including<br />

single license on a USB flash<br />

drive and electronic documentation<br />

SD card 256 KB (empty)<br />

ET200M incl.<br />

- 32 DI, 16 DO, 8 AI, 2 AO<br />

- FM350-2 8-channel counter<br />

- Front connector, bus<br />

connector, and mounting rail<br />

E 6AV6 652-2JD01-2AA1<br />

Configuration<br />

With SIMATIC WinCC flexible or<br />

SIMATIC WinCC<br />

see HMI software<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

2/149<br />

2


2<br />

Operator panels<br />

Multi Panels — 170 series<br />

SIMATIC MP 177<br />

■ Ordering data Order No. ■ Dimensional drawings<br />

Documentation<br />

(to be ordered separately)<br />

User manual MP 177 6" Touch<br />

German 6AV6 691-1DP02-0AA0<br />

English 6AV6 691-1DP02-0AB0<br />

French 6AV6 691-1DP02-0AC0<br />

Italian 6AV6 691-1DP02-0AD0<br />

Spanish 6AV6 691-1DP02-0AE0<br />

WinCC flexible<br />

Compact/Standard/Advanced<br />

User Manual<br />

German 6AV6 691-1AB01-3AA0<br />

English 6AV6 691-1AB01-3AB0<br />

French 6AV6 691-1AB01-3AC0<br />

Italian 6AV6 691-1AB01-3AD0<br />

Spanish 6AV6 691-1AB01-3AE0<br />

User Manual<br />

WinCC flexible Communication<br />

German 6AV6 691-1CA01-3AA0<br />

English 6AV6 691-1CA01-3AB0<br />

French 6AV6 691-1CA01-3AC0<br />

Italian 6AV6 691-1CA01-3AD0<br />

Spanish 6AV6 691-1CA01-3AE0<br />

SIMATIC HMI Manual Collection 6AV6 691-1SA01-0AX0<br />

Electronic documentation,<br />

on DVD<br />

5 languages (English, French,<br />

German, Italian and Spanish);<br />

contains: all currently available<br />

user manuals, manuals and<br />

communication manuals for<br />

SIMATIC HMI<br />

Accessories see HMI accessories<br />

2/150<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

All specifications in mm. Panel cutout see technical<br />

specifications.<br />

S<br />

MP 177 6" Touch<br />

212<br />

196<br />

SIMATIC MULTI PANEL<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-multi-panels<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.<br />

156<br />

140<br />

22<br />

44<br />

6<br />

G_<strong>ST</strong><strong>80</strong>_XX_00366


■ Overview<br />

Like operator panels, Multi Panels (MP) are used for local<br />

machine operation and monitoring<br />

Content of message buffer is retained even when panel is<br />

disconnected, without batteries<br />

PLC functionality can be integrated directly into the MP277<br />

platform with Option<br />

Their functionality can be expanded by the installation of<br />

additional Windows CE applications (Multi Panel and Panel<br />

options)<br />

SIMATIC MP 277 devices on the basis of Windows CE<br />

combine the rugged construction of Operator Panels with the<br />

flexibility of <strong>PC</strong>s<br />

Pixel-graphics 7.5" or 10.4" TFT display, color (64k colors)<br />

MP 277 8" and MP 277 10" Touch:<br />

Touch screen (analog/resistive)<br />

MP 277 8" Key:<br />

38 system keys, 26 user-configurable and freely inscribable<br />

function keys (18 with LEDs)<br />

MP 277 10" Key:<br />

38 system keys, 36 user-configurable and freely inscribable<br />

function keys (28 with LEDs)<br />

The MP 277 is also available with a stainless steel front panel<br />

and therefore meets the high requirements of, e.g. the food<br />

and beverage industry.<br />

All interfaces, e.g. MPI, PROFIBUS DP, USB, PROFINET<br />

(Ethernet TCP/IP), are onboard<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Multi Panels — 270 series<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC MP 277<br />

■ Benefits<br />

Integral component of Totally Integrated Automation (TIA):<br />

Increased productivity, minimum engineering overhead,<br />

reduction in life-cycle costs<br />

Modular expansion with options such as:<br />

- WinAC MP 277/Software PLC<br />

- WinCC flexible /Sm@rtAccess for communication between<br />

different SIMATIC HMI systems<br />

- WinCC flexible /Sm@rtService for remote maintenance and<br />

servicing of machines/plants via the intranet/Internet<br />

- WinCC flexible /O<strong>PC</strong>-Server for communication with<br />

applications from various manufacturers<br />

- Microsoft Pocket Internet Explorer (already included in<br />

scope of delivery)<br />

- WinCC flexible /ProAgent for selective and fast process fault<br />

diagnostics in systems and machines<br />

- WinCC flexible /Audit for user management (tracing and user<br />

operations)<br />

Reduction of service and commissioning costs through:<br />

- Backup/restore via Ethernet (TCP/IP), USB, MPI,<br />

PROFIBUS DP or optionally via SD/Multi Media Card<br />

- Remote download/upload of the configuration and firmware<br />

(Remote = automatic transfer recognition)<br />

- Specific drivers can be reloaded<br />

- Long service life of backlit display<br />

Graphic library available with off-the-shelf picture objects<br />

Can be used worldwide:<br />

- 32 languages can be configured (incl. Asian and Cyrillic<br />

character sets)<br />

- Up to 16 languages can be switched online<br />

Standard hardware and software interfaces for increasing<br />

flexibility:<br />

- SD/MultiMediaCard slot for memory expansions,<br />

backup/restore or additional interfaces<br />

- Ethernet (TCP/IP) for central data and project management<br />

Ethernet; control link possible to SIMATIC S7<br />

- Standard Windows storage formats (CSV) for archives and<br />

recipes permit further processing with standard tools<br />

(e.g. Microsoft Excel)<br />

■ Application<br />

These are used in the most diverse industries and applications<br />

and can be expanded in their applications with the Multi Panel<br />

options, e.g. by displaying HTML documents via the MS Pocket<br />

Internet Explorer, or by integrating the control functionality with<br />

WinAC MP 277.<br />

The diskless and fanless design permits their use even where<br />

dust or vibration limits the use of a <strong>PC</strong>. Short power-up times<br />

mean the Multi Panels are soon ready to use.<br />

2/151<br />

2


2<br />

Operator panels<br />

Multi Panels — 270 series<br />

SIMATIC MP 277<br />

■ Design<br />

Compact design with low mounting depth<br />

The front is resistant to various oils, greases and standard<br />

detergents<br />

Degree of protection IP65/NEMA 4x/NEMA 12 (front) or IP20<br />

(rear)<br />

Plug-in terminals for 24 V DC power supply<br />

Interfaces:<br />

- RS 485/ RS 422 interface for process connections<br />

(PPI, MPI, PROFIBUS DP up to 12 Mbit/s)<br />

- USB for memory stick, mouse, keyboard, printer, barcode<br />

reader, UPS and downloading/uploading the configuration<br />

- Ethernet (TCP/IP) for exchanging data with a higher-level<br />

<strong>PC</strong>, connection of a network printer and<br />

downloading/uploading the configuration;<br />

a control link to SIMATIC S7 is possible<br />

Slot for SD/MultiMedia card<br />

■ Function<br />

Display and modification of process parameters<br />

Function keys (for MP 277 8" Key and MP 277 10 "Key only)<br />

for direct triggering of functions and actions. Up to<br />

16 functions can be configured simultaneously on function<br />

keys.<br />

Process display:<br />

- VGA resolution (640 x 4<strong>80</strong> pixels)<br />

each with 64k colors for pixels<br />

- Vector graphics (various line and surface objects)<br />

- Dynamic positioning and dynamic showing/hiding of objects<br />

- Pixel-graphic displays, curves and bar displays<br />

- Presentation of up to 8 curves in a curve field;<br />

curve graphics with paging and zoom functions for access<br />

to the history and for flexible selection of the presentation<br />

time;<br />

reading ruler for determining the current values and<br />

displaying them in a table<br />

- Extensive symbol libraries (SIMATIC HMI symbol library)<br />

- Screen objects: Slider, gauge, clock<br />

- Cyclic function processing using timers<br />

Multiplex function for variables<br />

Signaling system<br />

- Bit messages and analog messages (limit value messages)<br />

- Freely-definable message classes (e.g. status/fault<br />

messages) for definition of acknowledgment response and<br />

display of message events<br />

- Status and fault messages with message history<br />

- Non-volatile, maintenance-free message buffer<br />

- Message window and message line<br />

2/152<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Archiving of messages and process values (on CF/SD/<br />

MultiMedia card/USB, etc., or network drives over Ethernet)<br />

- Various archive types: Circulating and sequence archive<br />

- Storage of archive data in standard Windows format (CSV)<br />

- Online evaluation of process value archives through trend<br />

curves<br />

- External processing using standard tools<br />

(MS Excel and MS Access) is possible<br />

Message log and shift log<br />

Print functions (see "Recommended printers")<br />

Language selection<br />

16 online languages, 32 configuration languages incl. Asian<br />

and Cyrillic character sets; language-dependent texts and<br />

graphics<br />

Recipe management<br />

- With additional data storage (on SD/MultiMedia card)<br />

- Online/offline processing on the panel<br />

- Storage of recipe data in standard Windows format (CSV)<br />

- External processing using standard tools (Microsoft Excel<br />

and Access) is possible<br />

TIA Runtime Functionalities<br />

- Direct keys (fast keys; with Key as keyboard image, with<br />

Touch freely customizable) used directly as PROFIBUS DP-<br />

or PROFINET IO input I/Os<br />

- With Key versions, LEDs additional as output I/Os<br />

- In addition, message process Alarm S with SIMATIC S7 and<br />

SIMOTION<br />

- Programming device functionality <strong>ST</strong>ATUS/FORCE-VAR in<br />

conjunction with SIMATIC S7<br />

- SIMATIC barcode scanner<br />

- Direct activation and evaluation of a SITOP UPS via USB<br />

Display selection from the PLC<br />

supports operator prompting from the PLC<br />

Presentation of HTML documents with MS Pocket Internet<br />

Explorer/WinCC flexible 2007 or higher<br />

Visual Basic Script, flexibility thanks to the implementation of<br />

new functions including linking to variables (comparison<br />

operations, loops, etc.)<br />

Help texts<br />

for process displays, messages, and variables<br />

Arithmetic functions<br />

Limit value monitoring<br />

for reliable process control of inputs and outputs<br />

Permanent window;<br />

Fixed top area of screen for outputting non-screen-specific<br />

information (e.g., important process values, date and time)


© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Multi Panels — 270 series<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC MP 277<br />

■ Function (continued)<br />

■ Integration<br />

Simple maintenance and configuration thanks to:<br />

The MP 277 can be connected in certain cases simultaneously<br />

- Save and load (Backup/Restore -> Image) of complete (multiprotocol-capable) to:<br />

(incl. License Keys as of WinCC flexible 2007) panel on an<br />

SD/MultiMedia Card (optional), also possible with remote<br />

SIMATIC S7-200/-300/-400<br />

access (Sm@rtService)<br />

SIMATIC WinAC Software/Slot PLC<br />

- Save and load (Backup/Restore -> Image) of complete SIMATIC WinAC MP<br />

(besides License Key) panel on a <strong>PC</strong><br />

- Configuration download via Ethernet/USB/MPI/PROFIBUS<br />

SIMATIC S5<br />

DP/Modem/http<br />

SIMATIC 505<br />

- Configuration upload over Ethernet/USB/MPI/PROFIBUS http communication with other SIMATIC HMI systems<br />

DP/modem/http, the project is compressed during the<br />

download and transferred to the SD/MultiMedia Card or<br />

SIMOTION<br />

USB stick (optional)<br />

SINUMERIK<br />

- Automatic Transfer Recognition (Remote Transfer)<br />

(optionally with "SINUMERIK HMI copy license WinCC flexible<br />

- Configuration simulation directly on the configuration<br />

CE"; "SINUMERIK HMI engineering package WinCC flexible"<br />

computer<br />

is additionally required for configuring;<br />

- Import/export of all texts incl. messages in CSV format for For further details, see <strong>Catalog</strong> NC 60)<br />

translation using standard text processing programs<br />

O<strong>PC</strong> XML server<br />

- Centrally modifiable project-specific faceplates<br />

Third-party controllers<br />

Template<br />

- Allen Bradley<br />

- Creation of screen templates:<br />

- Mitsubishi<br />

- Position-independent configuration of background objects - LG GLOFA GM<br />

Password system<br />

- Modicon<br />

- User-oriented access protection according to requirements - GE-Fanuc<br />

of specific sectors<br />

-Omron<br />

- Authentication with user ID and password<br />

- Telemecanique Uni-Telway<br />

- User-group-specific rights<br />

Via Ethernet (TCP/IP) to a higher-level <strong>PC</strong>, with enabled<br />

Service functions<br />

network printer<br />

(optionally with "WinCC flexible /Sm@rtService")<br />

- Email generation<br />

Note:<br />

- Remote control of the SIMATIC HMI system based on<br />

Internet Explorer<br />

Further information can be found under "System interfaces".<br />

- Web server with status HTML pages and control functions<br />

Client/server functions<br />

(optionally with "WinCC flexible /Sm@rtAccess")<br />

- Remote operation and monitoring from other<br />

SIMATIC HMI systems<br />

- Plant-wide requests for information and archiving of process<br />

data<br />

Configuration<br />

The configuration is implemented using the<br />

SIMATIC WinCC Comfort engineering software. Projects<br />

generated with WinCC flexible can be migrated to WinCC.<br />

Applications/options<br />

WinAC MP software PLC for Multi Panels<br />

WinAC MP 277 option for MP 277 (software PLC similar to<br />

performance class CPU 315)<br />

The I/O can be connected via PROFIBUS DP<br />

Sm@rtServer:<br />

Remote control and monitoring as well as communication<br />

between different SIMATIC HMI systems<br />

O<strong>PC</strong> server:<br />

Communication with applications (e.g. MES, ERP, or<br />

applications in the office sector) from various manufacturers<br />

2/153<br />

2


2<br />

Operator panels<br />

Multi Panels — 270 series<br />

SIMATIC MP 277<br />

■ Technical specifications<br />

6AV6 643-0CB01-1AX1 6AV6 643-0CD01-1AX1 6AV6 643-0DB01-1AX1 6AV6 643-0DD01-1AX1<br />

Product type designation<br />

Display<br />

8" Color Touch 10" Color Touch 8" Color Keyboard 10" Color Keyboard<br />

Size 7.5" 10.4" 7.5" 10.4"<br />

Display type<br />

Resolution (pixels)<br />

TFT, 65536 colors TFT, 65536 colors TFT, 65536 colors TFT, 65536 colors<br />

Resolution (WxH in pixel)<br />

Backlighting<br />

640 x 4<strong>80</strong> 640 x 4<strong>80</strong> 640 x 4<strong>80</strong> 640 x 4<strong>80</strong><br />

MTBF backlighting<br />

(at 25 °C)<br />

Control elements<br />

about 50,000 hours about 50,000 hours about 50,000 hours about 50,000 hours<br />

Control elements Touch screen Touch screen Membrane keyboard Membrane keyboard<br />

Function keys, programmable<br />

Connection for<br />

mouse/keyboard/barcode<br />

reader<br />

2/154<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

26 function keys, 18 with<br />

LEDs<br />

36 function keys, 28 with<br />

LEDs<br />

USB / USB / USB USB / USB / USB USB / USB / USB USB / USB / USB<br />

Keyboard<br />

System keys 36 36<br />

Numeric/alphabetical input<br />

Touch operation<br />

Yes / Yes Yes / Yes Yes / Yes Yes / Yes<br />

Touch screen<br />

Supply voltage<br />

Input voltage<br />

analog, resistive analog, resistive<br />

permissible range +20.4 V to +28.8 V DC +20.4 V to +28.8 V DC +20.4 V to +28.8 V DC +20.4 V to +28.8 V DC<br />

Supply voltage<br />

Processor<br />

24 V DC 24 V DC 24 V DC 24 V DC<br />

Processor<br />

Memory<br />

ARM ARM ARM ARM<br />

Type Flash / RAM Flash / RAM Flash / RAM Flash / RAM<br />

Usable memory for user data 6 MB usable memory for<br />

user data<br />

6 MB usable memory for<br />

user data<br />

6 MB usable memory for<br />

user data<br />

Type of output<br />

LED colors Green Green<br />

Time of day<br />

Clock<br />

Type Hardware clock, battery<br />

backup, synchronizable<br />

Interfaces<br />

Interfaces 1 x RS422, 1 x RS485,<br />

1 x Ethernet (RJ45)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Hardware clock, battery<br />

backup, synchronizable<br />

1 x RS422, 1 x RS485,<br />

1 x Ethernet (RJ45)<br />

Hardware clock, battery<br />

backup, synchronizable<br />

1 x RS422, 1 x RS485,<br />

1 x Ethernet (RJ45)<br />

6 MB usable memory for<br />

user data<br />

Hardware clock, battery<br />

backup, synchronizable<br />

1 x RS422, 1 x RS485,<br />

1 x Ethernet (RJ45)<br />

USB port 2 x USB 2 x USB 2 x USB 2 x USB<br />

Multi Media Card slot<br />

Industrial Ethernet<br />

1 x Multi Media Card slot 1 x Multi Media Card slot 1 x Multi Media Card slot 1 x Multi Media Card slot<br />

Industrial Ethernet interface<br />

Ambient conditions<br />

Operating temperature<br />

1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45)<br />

Operation<br />

Storage/transport temperature<br />

0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °C<br />

Transport, storage<br />

Relative humidity<br />

-20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C<br />

max. relative humidity 90 % 90 % 90 % 90 %<br />

Mounting position vertical vertical vertical vertical<br />

maximum permissible angle<br />

of inclination without external<br />

ventilation<br />

+/- 35 ° +/- 35 ° +/- 35 ° +/- 35 °


■ Technical specifications (continued)<br />

Degree and class of<br />

protection<br />

Front IP65, NEMA 4x,<br />

(when installed)<br />

IP65, NEMA 4x,<br />

(when installed)<br />

IP65, NEMA 4x,<br />

(when installed)<br />

Rear IP20 IP20 IP20 IP20<br />

Standards, approvals,<br />

certificates<br />

Certifications CE, FM Class I Div. 2, UL,<br />

cULus, EX-Zone 22, NEMA<br />

4x (Enclosure Type 4X,<br />

Type 12)<br />

CE, FM Class I Div. 2, UL,<br />

cULus, EX-Zone 22, NEMA<br />

4x (Enclosure Type 4X,<br />

Type 12)<br />

Operator panels<br />

Multi Panels — 270 series<br />

CE, UL, cULus, NEMA 4x<br />

(Enclosure Type 4X,<br />

Type 12)<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC MP 277<br />

IP65, NEMA 4x,<br />

(when installed)<br />

CE, FM Class I Div. 2, UL,<br />

cULus, EX-Zone 22, NEMA<br />

4x (Enclosure Type 4X,<br />

Type 12)<br />

Operating systems<br />

Operating system<br />

Configuration<br />

Configuration software<br />

Windows CE Windows CE Windows CE Windows CE<br />

Configuration tool<br />

Functionality under<br />

WinCC flexible/WinCC<br />

(TIA portal)<br />

see "Configuration overview" from page 2/3<br />

Applications/options see chapter 4: HMI software/SIMATIC WinCC flexible options and SIMATIC WinCC (TIA portal) options<br />

Number of Visual Basic<br />

Scripts<br />

50 50 50 50<br />

Task planner Yes Yes Yes Yes<br />

Help system Yes Yes Yes Yes<br />

Status/control<br />

With alarm logging system<br />

(incl. buffer and acknowledgment)<br />

with SIMATIC S7 with SIMATIC S7 with SIMATIC S7 with SIMATIC S7<br />

Number of messages 4000 4 000 4000 4000<br />

Bit messages Yes Yes Yes Yes<br />

Analog messages Yes Yes Yes Yes<br />

Message buffer Ring buffer (n x 512<br />

entries), retentive,<br />

maintenance-free<br />

Ring buffer (n x 512<br />

entries), retentive,<br />

maintenance-free<br />

Ring buffer (n x 512<br />

entries), retentive,<br />

maintenance-free<br />

Recipes<br />

Recipes 300 300 300 300<br />

Data records per recipe 500 500 500 500<br />

Entries per data record 1000 1000 1000 1000<br />

Recipe memory 64 KB integrated Flash,<br />

expandable<br />

64 KB integrated Flash,<br />

expandable<br />

64 KB integrated Flash,<br />

expandable<br />

Ring buffer (n x 512<br />

entries), retentive,<br />

maintenance-free<br />

64 KB integrated Flash,<br />

expandable<br />

Number of process images<br />

Process images 500 500 500 500<br />

Variables 2048 2 048 2048 2048<br />

Limit values Yes Yes Yes Yes<br />

Multiplexing<br />

Image elements<br />

Yes Yes Yes Yes<br />

Text objects 10,000 text elements 10,000 text elements 10,000 text elements 10,000 text elements<br />

Graphic object Bit maps, icons, vector Bit maps, icons, vector Bit maps, icons, vector Bit maps, icons, vector<br />

graphics<br />

graphics<br />

graphics<br />

graphics<br />

dynamic objects Diagrams, bar graphs,<br />

sliders, analog display,<br />

invisible buttons<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV6 643-0CB01-1AX1 6AV6 643-0CD01-1AX1 6AV6 643-0DB01-1AX1 6AV6 643-0DD01-1AX1<br />

Product type designation 8" Color Touch 10" Color Touch 8" Color Keyboard 10" Color Keyboard<br />

Diagrams, bar graphs,<br />

sliders, analog display,<br />

invisible buttons<br />

Diagrams, bar graphs,<br />

sliders, analog display,<br />

invisible buttons<br />

Diagrams, bar graphs,<br />

sliders, analog display,<br />

invisible buttons<br />

2/155<br />

2


2<br />

Operator panels<br />

Multi Panels — 270 series<br />

SIMATIC MP 277<br />

■ Technical specifications (continued)<br />

6AV6 643-0CB01-1AX1 6AV6 643-0CD01-1AX1 6AV6 643-0DB01-1AX1 6AV6 643-0DD01-1AX1<br />

Product type designation 8" Color Touch 10" Color Touch 8" Color Keyboard 10" Color Keyboard<br />

Lists<br />

Text lists 500 500 500 500<br />

Graphic list 400 400 400 400<br />

Libraries<br />

Archiving<br />

Yes Yes Yes Yes<br />

Number of archives per<br />

project<br />

20 20 20 20<br />

Number of measuring<br />

points per project<br />

20 20 20 20<br />

Number of entries per<br />

archive<br />

10 000 10 000 10 000 10 000<br />

Memory location<br />

Security<br />

SD and Multi Media Card SD and Multi Media Card SD and Multi Media Card SD and Multi Media Card<br />

Number of user groups 50 50 50 50<br />

Passwords exportable Yes Yes Yes Yes<br />

Number of user rights<br />

Data carrier support<br />

32 32 32 32<br />

Multimedia Card Yes Yes Yes Yes<br />

Recording<br />

Recording/Printing Alarms, report (shift report),<br />

color print, hardcopy<br />

2/156<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Alarms, report (shift report),<br />

color print, hardcopy<br />

Alarms, report (shift report),<br />

color print, hardcopy<br />

Alarms, report (shift report),<br />

color print, hardcopy<br />

Fonts<br />

Keyboard fonts US American (English) US American (English) US American (English) US American (English)<br />

Languages<br />

Configuration languages D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified",<br />

DK, FIN, GR, J, KP / ROK,<br />

NL, N, PL, P, RUS, S, CZ /<br />

SK, TR, H<br />

Character sets Tahoma, Arial, Courier<br />

New, WinCC flexible<br />

Standard, symbol<br />

languages, all freely<br />

scalable<br />

Transfer (upload/download)<br />

Transfer of configuration MPI/PROFIBUS DP, USB,<br />

Ethernet, automatic transfer<br />

recognition<br />

D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified",<br />

DK, FIN, GR, J, KP / ROK,<br />

NL, N, PL, P, RUS, S, CZ /<br />

SK, TR, H<br />

Tahoma, Arial, Courier<br />

New, WinCC flexible<br />

Standard, symbol<br />

languages, all freely<br />

scalable<br />

MPI/PROFIBUS DP, USB,<br />

Ethernet, automatic transfer<br />

recognition<br />

D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified",<br />

DK, FIN, GR, J, KP / ROK,<br />

NL, N, PL, P, RUS, S, CZ /<br />

SK, TR, H<br />

Tahoma, Arial, Courier<br />

New, WinCC flexible<br />

Standard, symbol<br />

languages, all freely<br />

scalable<br />

MPI/PROFIBUS DP, USB,<br />

Ethernet, automatic transfer<br />

recognition<br />

D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified",<br />

DK, FIN, GR, J, KP / ROK,<br />

NL, N, PL, P, RUS, S, CZ /<br />

SK, TR, H<br />

Tahoma, Arial, Courier<br />

New, WinCC flexible<br />

Standard, symbol<br />

languages, all freely<br />

scalable<br />

MPI/PROFIBUS DP, USB,<br />

Ethernet, automatic transfer<br />

recognition<br />

Process coupling<br />

Connection to controller<br />

Expandability/openness<br />

see "System interfaces" from page 2/178<br />

Open Platform Program<br />

I/O<br />

Yes Yes Yes Yes<br />

I/O devices<br />

Dimensions and weight<br />

Dimensions<br />

Printer, barcode reader Printer, barcode reader Printer, barcode reader Printer, barcode reader<br />

Front of enclosure (W x H) 240 mm x 1<strong>80</strong> mm 325 mm x 263 mm 352 mm x 221 mm 483 mm x 310 mm<br />

Mounting cutout/device<br />

depth (W x H)<br />

226 mm x 166 mm / 60 mm<br />

device depth<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

310 mm x 248 mm / 61 mm<br />

device depth<br />

338 mm x 206 mm / 61 mm<br />

device depth<br />

Weight<br />

Weight 1.61 kg 2.65 kg 2.25 kg 4.95 kg<br />

434 mm x 291 mm / 60 mm<br />

device depth


Operator panels<br />

Multi Panels — 270 series<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC MP 277<br />

■ Ordering data Order No. Order No.<br />

SIMATIC MP 277<br />

Starter package<br />

E 6AV6 652-3LD01-1AA0<br />

Multi Panel (including mounting<br />

636K WinAC MP<br />

accessories) with<br />

Consisting of:<br />

8" color TFT display, Touch E 6AV6 643-0CB01-1AX1<br />

SIMATIC MP 277 8" Key with<br />

10" color TFT display, Touch E<br />

8" color TFT display, keyboard E<br />

10" color TFT display, keyboard E<br />

6AV6 643-0CD01-1AX1<br />

6AV6 643-0DB01-1AX1<br />

6AV6 643-0DD01-1AX1<br />

mounting accessories,<br />

mounting gasket, and power<br />

connector<br />

SIMATIC WinAC MP incl. single<br />

SIMATIC MP 277 8" Touch E 6AV6 652-3MB01-0AA0<br />

license on USB stick and<br />

Starter Package<br />

electronic documentation<br />

Consisting of:<br />

SD Card 256 KB (blank)<br />

SIMATIC MP 277 8" Touch<br />

ET200M incl.<br />

SIMATIC WinCC flexible 2007<br />

- 32 DI, 16 DO, 8 AI, 2 AO<br />

SIMATIC HMI Manual Collection<br />

MPI cable, 5 m (for download<br />

- Front connector, bus<br />

connector, and mounting rail<br />

and test purposes only)<br />

Starter package<br />

E 6AV6 652-3PD01-1AA0<br />

<strong>PC</strong>/PPI cable (RS 232)<br />

636T WinAC MP<br />

SIMATIC MP 277 10" Touch E 6AV6 652-3PB01-0AA0<br />

Consisting of:<br />

Starter Package<br />

SIMATIC MP 277 10" Touch with<br />

Consisting of:<br />

SIMATIC MP 277 10" Touch<br />

mounting accessories,<br />

mounting seal, power supply<br />

connector<br />

SIMATIC WinCC flexible 2007<br />

SIMATIC WinAC MP including<br />

SIMATIC HMI Manual Collection<br />

single license on a USB flash<br />

MPI cable, 5 m (for download<br />

and test purposes only)<br />

drive and electronic documentation<br />

<strong>PC</strong>/PPI cable (RS232)<br />

SD Card 256 KB (blank)<br />

Promotion package E 6AV6 652-3PB01-2AA0<br />

ET200M incl.<br />

- 32 DI, 16 DO, 8 AI, 2 AO<br />

Consisting of:<br />

- Front connector, bus<br />

SIMATIC MP 277 10" Touch<br />

connector, and mounting rail<br />

SIMATIC THIN CLIENT<br />

10" Touch<br />

SIMATIC WinCC flexible 2008<br />

Complete pre-assembled<br />

packages SIMATIC MP 277 with<br />

WinAC MP 2007<br />

SIMATIC HMI Manual Collection<br />

Ethernet cable, 2 m<br />

MPI cable, 5 m (for download<br />

and test purposes only)<br />

Sm@rtAccess (Single License)<br />

Package MP 277 8" Touch<br />

MP 277 8" Touch<br />

Electronic documentation<br />

Single license for MP 277 on<br />

USB flash drive<br />

E 6AV6 652-3MC01-1AA0<br />

Starter package<br />

E 6AV6 652-3LD01-1AA1<br />

635K WinAC MP<br />

Consisting of:<br />

SIMATIC MP 277 8" Key with<br />

mounting accessories,<br />

mounting seal, power supply<br />

connector<br />

SIMATIC WinAC MP incl. single<br />

license on USB stick and<br />

electronic documentation<br />

SD card 256 KB (empty)<br />

ET200M incl.<br />

- 32 DI, 16 DO, 8 AI, 2 AO<br />

- FM350-2 8-channel counter<br />

- Front connector, bus<br />

connector, and mounting rail<br />

1)<br />

Standard SD Card (empty)<br />

Package MP 277 8" Key E 6AV6 652-3LC01-1AA0<br />

MP 277 8" Key<br />

Electronic documentation<br />

Single license for MP 277 on<br />

USB flash drive1) Standard SD Card (empty)<br />

Package MP 277 10" Touch E 6AV6 652-3<strong>PC</strong>01-1AA0<br />

MP 277 10" Touch<br />

Electronic documentation<br />

Single license for MP 277 on<br />

USB flash drive1) Standard SD Card (empty)<br />

Package MP 277 10" Key E 6AV6 652-3NC01-1AA0<br />

MP 277 10" Key<br />

Electronic documentation<br />

Single license for MP 277 on<br />

USB flash drive1) Standard SD Card (empty)<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

1) Can only be used for license handling<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

2/157<br />

2


2<br />

Operator panels<br />

Multi Panels — 270 series<br />

SIMATIC MP 277<br />

■ Ordering data Order No. Order No.<br />

Configuration<br />

With SIMATIC WinCC flexible or<br />

SIMATIC WinCC<br />

see HMI Software<br />

Configuration set<br />

Consisting of:<br />

WinCC flexible Standard<br />

engineering software<br />

Documentation DVD,<br />

5 languages (English, French,<br />

German, Italian, Spanish)<br />

RS 232 cable (5 m)<br />

MPI cable, 5 m<br />

Applications/Options<br />

D 6AV6 622-0BA01-0AA0<br />

For configuration with<br />

WinCC flexible<br />

WinCC flexible /Sm@rtAccess<br />

WinCC flexible /Sm@rtService<br />

WinCC flexible /O<strong>PC</strong> server<br />

WinCC flexible /ProAgent<br />

WinCC flexible /Audit<br />

WinAC MP 2007/Software PLC<br />

Documentation<br />

(to be ordered separately)<br />

MP 277 Operating Instructions<br />

see HMI Software<br />

German 6AV6 691-1DJ01-0AA0<br />

English 6AV6 691-1DJ01-0AB0<br />

French 6AV6 691-1DJ01-0AC0<br />

Italian 6AV6 691-1DJ01-0AD0<br />

Spanish 6AV6 691-1DJ01-0AE0<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

2/158<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

WinCC flexible<br />

Compact/Standard/Advanced<br />

User Manual<br />

German 6AV6 691-1AB01-3AA0<br />

English 6AV6 691-1AB01-3AB0<br />

French 6AV6 691-1AB01-3AC0<br />

Italian 6AV6 691-1AB01-3AD0<br />

Spanish 6AV6 691-1AB01-3AE0<br />

User Manual<br />

WinCC flexible Communication<br />

German 6AV6 691-1CA01-3AA0<br />

English 6AV6 691-1CA01-3AB0<br />

French 6AV6 691-1CA01-3AC0<br />

Italian 6AV6 691-1CA01-3AD0<br />

Spanish 6AV6 691-1CA01-3AE0<br />

SIMATIC HMI Manual Collection B 6AV6 691-1SA01-0AX0<br />

Electronic documentation,<br />

on DVD<br />

5 languages (English, French,<br />

German, Italian and Spanish);<br />

contains: all currently available<br />

user manuals, manuals and<br />

communication manuals for<br />

SIMATIC HMI<br />

Accessories see HMI accessories


■ Dimensional drawings<br />

All specifications in mm (tolerance ± 1 mm). Panel cutout see<br />

technical specifications.<br />

MP 277 8" Touch<br />

275<br />

190<br />

SIEMENS<br />

SIEMENS<br />

MP 277 10" Touch<br />

335<br />

250<br />

225<br />

SIMATIC MULTI PANEL<br />

SIMATIC MULTI PANEL<br />

309<br />

260 20<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-multi-panels<br />

165<br />

160<br />

247<br />

43<br />

47<br />

61 6<br />

61 6<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00285<br />

G_<strong>ST</strong><strong>80</strong>_XX_00284<br />

MP 277 8" Key<br />

310<br />

231<br />

MP 277 10" Key<br />

SIEMENS SIMATIC MULTI PANEL<br />

SIEMENS<br />

77<br />

224<br />

362<br />

337<br />

260<br />

Operator panels<br />

Multi Panels — 270 series<br />

483<br />

432<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC MP 277<br />

61 6<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.<br />

205<br />

121<br />

SIMATIC MULTI PANEL<br />

47<br />

289<br />

107<br />

G_<strong>ST</strong><strong>80</strong>_XX_00286<br />

55 10<br />

G_<strong>ST</strong><strong>80</strong>_XX_00287<br />

2/159<br />

2


2<br />

Operator panels<br />

Multi Panels — 370 series<br />

SIMATIC MP 377<br />

■ Overview<br />

Like operator panels, Multi Panels (MP) are used for local<br />

machine operation and monitoring<br />

Their functionality can be expanded by installing additional<br />

Windows CE applications (Multi Panel and Panel options)<br />

SIMATIC MP 377 devices on the basis of Windows CE<br />

combine the rugged construction of Operator Panels with the<br />

flexibility of <strong>PC</strong>s<br />

PLC functionality can be integrated directly into the MP 377<br />

platform with Option<br />

Pixel-graphics 12.1" or 15" or 19" TFT display, color<br />

(64k colors)<br />

MP 377 12" Touch, MP 377 15" Touch and MP 377 19" Touch:<br />

Touch screen (analog/resistive)<br />

MP 377 12" Key:<br />

38 system keys, 36 user-configurable and freely inscribable<br />

function keys (36 with LEDs)<br />

SIMATIC MP 377 PRO 15" Touch:<br />

with a rugged and very compact aluminum enclosure, fully<br />

enclosed with IP65 protection and therefore suitable for harsh<br />

ambient conditions.<br />

All interfaces, e.g. MPI, PROFIBUS DP, USB, PROFINET<br />

(Ethernet TCP/IP), are onboard<br />

SIMATIC MP 377 INOX 15" Touch (stainless steel front):<br />

The MP 377 15" Touch is also available with a stainless steel<br />

front (EN 1672-2) and as Fully Enclosed HMI (IP65). These<br />

versions expand the application area of the Multi Panel 377 for<br />

special applications, ambient conditions, and special sectors<br />

(e.g. food, beverages and tobacco industries).<br />

2/160<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Integral component of Totally Integrated Automation (TIA):<br />

Increase of productivity, minimization of engineering<br />

overhead, reduction of lifecycle costs<br />

Modular expansion capability with options such as:<br />

- Software PLC SIMATIC WinAC MP<br />

- WinCC Sm@rtServer for communication between different<br />

SIMATIC HMI systems<br />

- WinCC Sm@rtServer for remote maintenance and servicing<br />

of machines/plants via the Internet/Intranet<br />

- WinCC O<strong>PC</strong> server for communication with applications from<br />

different manufacturers<br />

- MS Pocket Internet Explorer 6.0 (already included in the<br />

scope of delivery)<br />

- MS Multimedia Player (already included in the scope of<br />

delivery)<br />

- MS Viewer for Word, Excel and PDF files (already included in<br />

scope of delivery)<br />

Reduction of service and commissioning costs due to:<br />

- Backup/restore via Ethernet (TCP/IP), USB, MPI,<br />

PROFIBUS DP or optionally via CF/SD/Multimedia Card<br />

- Remote download/upload for configuration and firmware<br />

- Specific drivers can be reloaded<br />

- Long service life of backlit display<br />

Graphic library with preconfigured screen objects<br />

Can be used worldwide:<br />

- 32 languages can be configured (incl. Asian and Cyrillic<br />

character sets)<br />

- Up to 16 languages can be switched online<br />

Standard hardware and software interfaces for increasing<br />

flexibility:<br />

- CF Card slot and SD/Multimedia Card slot for language<br />

expansions, backup/restore<br />

- Ethernet (TCP/IP) for central data and project management<br />

and control link possible to SIMATIC S7<br />

- Standard Windows storage formats (CSV) for archives and<br />

recipes permit further processing with standard tools<br />

(e. g. Microsoft Excel)


■ Application<br />

The Multi Panels SIMATIC MP 377 can be used wherever<br />

machines and systems are operated and monitored locally –<br />

whether in production, process or building automation. These<br />

are used in the most diverse industries and applications and can<br />

be expanded in their applications with the Multi Panel options,<br />

e.g. by displaying HTML documents via the MS Pocket Internet<br />

Explorer, or by integrating the control functionality with WinAC<br />

MP 377.<br />

Windows CE meets the basic prerequisites for application in<br />

rough industrial environments. The diskless and fanless design<br />

permits their use even where dust or vibration limits the<br />

operation of a <strong>PC</strong>. Short power-up times mean the Multi Panels<br />

are sooner ready to use.<br />

■ Design<br />

Compact design with low mounting depth<br />

The front is resistant to various oils, greases and standard<br />

detergents<br />

Degree of protection IP65/NEMA 4x/NEMA 12 (front) or IP20<br />

(rear)<br />

Plug-in terminals for 24 V DC power supply<br />

Interfaces:<br />

- RS 485/RS 422 interface for process connections<br />

(MPI, PROFIBUS DP up to 12 Mbit/s)<br />

- USB for mouse, keyboard, printer, barcode reader, and<br />

downloading/uploading the configuration<br />

- Ethernet (TCP/IP) for exchanging data with a higher-level<br />

<strong>PC</strong>, connection of a network printer and<br />

downloading/uploading the configuration; a control link to<br />

SIMATIC S7 is possible<br />

Slot for CompactFlash card (CF card)<br />

Slot for SD/multimedia card<br />

Retentive memory for WinAC MP 377 data (data, timers,<br />

counters and bit memories)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Multi Panels — 370 series<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC MP 377<br />

■ Function<br />

Display and changing of process parameters<br />

Function keys (for MP 377 12" Keys)<br />

for direct triggering of functions and actions. Up to<br />

16 functions can be configured simultaneously on function<br />

keys. The function keys can be used directly as PROFIBUS DP<br />

input I/O.<br />

Process display:<br />

- Vector graphic (various line and plane objects)<br />

- Dynamic positioning and dynamic showing/hiding of objects<br />

- Fully-graphical displays, plots, and bar graph display<br />

- Display of up to 8 trends per trend field;<br />

trend curve graphic with scroll and zoom functions for<br />

accessing the history and flexible selection of the<br />

representation period;<br />

read ruler for determining current values and display in a<br />

table<br />

- Extensive symbol libraries (SIMATIC HMI symbol library)<br />

- Screen objects: Slider, gauge, clock<br />

- Cyclic function processing by alarm clock<br />

Multiplex function for variables<br />

Signaling system<br />

- Discrete alarms and analog messages (limit value<br />

messages) as well as the Alarm S message frame procedure<br />

for SIMATIC S7 and SIMOTION<br />

- Freely-definable message classes (e. g. status/fault<br />

messages) for definition of acknowledgment response and<br />

display of message events<br />

- Status and fault messages with message history<br />

- Pre-configured message image, message window and<br />

message line<br />

Archiving of messages and process values (on CF/SD/Multi-<br />

Media card/USB, etc., or network drives over Ethernet)<br />

- Various archive types: Circulating and sequence archive<br />

- Storage of archive data in standard Windows format (CSV)<br />

- Online evaluation of process value archives using trend<br />

curves<br />

- External evaluation using standard tools (MS Excel,<br />

MS Access) is possible<br />

Alarm log and shift log<br />

Print functions (see "Recommended printers")<br />

Language switching<br />

16 online languages, 32 configuration languages incl. Asiatic<br />

and Cyrillic character sets<br />

Recipe management<br />

- With additional data storage (on CF/SD/Multimedia<br />

Card/USB flash drive, etc.)<br />

- Online/offline processing on the panel<br />

- Storage of recipe data in standard Windows format (CSV)<br />

- External processing using standard tools (Microsoft Excel<br />

and Access) is possible<br />

2/161<br />

2


2<br />

Operator panels<br />

Multi Panels — 370 series<br />

SIMATIC MP 377<br />

■ Function (continued)<br />

■ Integration<br />

Programming device functionality <strong>ST</strong>ATUS/ FORCE-VAR in More detailed information on this topic can be found under<br />

conjunction with SIMATIC S5 and SIMATIC S7<br />

"System interfaces with WinCC flexible" or "System interfaces<br />

Display selection from the PLC<br />

with WinCC (TIA Portal)".<br />

supports operator prompting from the PLC<br />

Presentation of HTML documents with MS Pocket Internet ■ Configuration<br />

Explorer<br />

The configuration is implemented using the SIMATIC WinCC<br />

Visual Basic Script, flexibility thanks to the implementation of flexible or WinCC engineering software (TIA Portal).<br />

new functions including linking to variables (comparison<br />

operations, loops, etc.)<br />

More detailed information on this topic can be found under<br />

Help texts<br />

"HMI Software".<br />

for process pictures, alarms, and tags<br />

Applications/Options<br />

Arithmetic functions<br />

More detailed information on this topic can be found under<br />

Limit value monitoring<br />

"HMI Software".<br />

for reliable process control of inputs and outputs<br />

Permanent window;<br />

- Fixed area of screen for outputting non-screen-specific<br />

information (e.g. important process values, date and time)<br />

- Permanent window expanded by template concept for<br />

creating screen templates<br />

Simple maintenance and configuration thanks to:<br />

- Backup and restoring of configuration, operating system,<br />

data records, and firmware on an optional memory card<br />

(CF/SD/Multimedia Card) or via the Ethernet<br />

- Backup and restoration of the configuration, operating<br />

system, data records and firmware on a <strong>PC</strong><br />

- Download/upload of configuration via<br />

Ethernet/USB/MPI/PROFIBUS DP/modem and CF or<br />

SD/Multimedia Card<br />

- Automatic transfer detection<br />

- Configuration simulation directly on the configuration<br />

computer<br />

Import/export of all texts incl. messages in CSV format for<br />

translation using standard text processing programs<br />

Centrally modifiable project-specific faceplates<br />

User administration (security)<br />

- User-oriented access protection according to requirements<br />

of specific sectors<br />

- Authentication with user ID and password<br />

- User-group-specific rights<br />

Visual Basic Runtime object model<br />

Service functions (optionally with "WinCC Sm@rtServer")<br />

- Email generation<br />

- Remote control of the SIMATIC HMI system based on<br />

Internet Explorer<br />

- Web server with status HTML pages and control functions<br />

Client/server functions (optionally with "WinCC Sm@rtServer")<br />

- Remote operation and monitoring from other<br />

SIMATIC HMI systems<br />

- Plant-wide requests for information and archiving of process<br />

data<br />

2/162<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Technical specifications<br />

Operator panels<br />

Multi Panels — 370 series<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC MP 377<br />

6AV6 644-0AA01-2AX0 6AV6 644-0BA01-2AX1 6AV6 644-0AB01-2AX0 6AV6 644-0AC01-2AX1<br />

Product type designation<br />

Display<br />

12" Touch 12" Key 15" Touch 19" Touch<br />

Size 12.1" (246 mm x 184.5 mm) 12.1" (246 mm x 184.5 mm) 15" (304.1 mm x 228.1 mm) 19" (376.3 mm x 301.1 mm)<br />

Display type<br />

Resolution (pixels)<br />

TFT, 65536 colors TFT, 65536 colors TFT, 65536 colors TFT, 65536 colors<br />

Resolution (WxH in pixel)<br />

Backlighting<br />

<strong>80</strong>0 x 600 <strong>80</strong>0 x 600 1024 x 768 12<strong>80</strong> x 1024<br />

MTBF backlighting<br />

(at 25 °C)<br />

Control elements<br />

about 50,000 hours about 50,000 hours about 50,000 hours about 50,000 hours<br />

Control elements Touch screen Membrane keyboard Touch screen Touch screen<br />

Function keys, programmable<br />

Connection for<br />

mouse/keyboard/barcode<br />

reader<br />

USB / USB / USB<br />

36 function keys, 36 with<br />

LEDs<br />

USB / USB / USB USB / USB / USB USB / USB / USB<br />

Keyboard<br />

System keys 38<br />

Numeric/alphabetical input<br />

Touch operation<br />

Yes / Yes Yes / Yes Yes / Yes Yes / Yes<br />

Touch screen<br />

Supply voltage<br />

Input voltage<br />

analog, resistive analog, resistive analog, resistive<br />

permissible range +19.2 V to +28.8 V DC +19.2 V to +28.8 V DC +19.2 V to +28.8 V DC +19.2 V to +28.8 V DC<br />

Supply voltage<br />

Input current<br />

24 V DC 24 V DC 24 V DC 24 V DC<br />

Rated current<br />

Memory<br />

1.5 A 1.5 A 1.9 A 2.5 A<br />

Type Flash / RAM Flash / RAM Flash / RAM Flash / RAM<br />

Usable memory for user data 12288 KB usable memory<br />

for user data / 12288 KB<br />

additional memory for<br />

options<br />

12288 KB usable memory<br />

for user data / 12288 KB<br />

additional memory for<br />

options<br />

12288 KB usable memory<br />

for user data / 12288 KB<br />

additional memory for<br />

options<br />

12288 KB usable memory<br />

for user data / 12288 KB<br />

additional memory for<br />

options<br />

Type of output<br />

LED colors Red, green<br />

Acoustics WAV sound signal WAV sound signal WAV sound signal WAV sound signal<br />

Time of day<br />

Clock<br />

Type Hardware clock, battery<br />

backup, synchronizable<br />

Interfaces<br />

Interfaces 1 x RS422, 1 x RS485,<br />

2 x Ethernet (RJ45)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Hardware clock, battery<br />

backup, synchronizable<br />

1 x RS422, 1 x RS485,<br />

2 x Ethernet (RJ45)<br />

Hardware clock, battery<br />

backup, synchronizable<br />

1 x RS422, 1 x RS485,<br />

2 x Ethernet (RJ45)<br />

Hardware clock, battery<br />

backup, synchronizable<br />

1 x RS422, 1 x RS485,<br />

2 x Ethernet (RJ45)<br />

USB port 2 x USB 2 x USB 2 x USB 2 x USB<br />

CF card slot 1 x CF card slot 1 x CF card slot 1 x CF card slot 1 x CF card slot<br />

Multi Media Card slot<br />

Industrial Ethernet<br />

1 x Multi Media Card slot 1 x Multi Media Card slot 1 x Multi Media Card slot 1 x Multi Media Card slot<br />

Industrial Ethernet interface<br />

Protocols<br />

Protocols (terminal link)<br />

2 x Ethernet (RJ45) 2 x Ethernet (RJ45) 2 x Ethernet (RJ45) 2 x Ethernet (RJ45)<br />

Sm@rtAccess<br />

EMC<br />

Emission of radio interference<br />

acc. to EN 55 011<br />

Yes Yes Yes Yes<br />

Emission of radio interferences<br />

acc. to EN 55 011<br />

(limit class A)<br />

Yes Yes Yes Yes<br />

2/163<br />

2


2<br />

Operator panels<br />

Multi Panels — 370 series<br />

SIMATIC MP 377<br />

■ Technical specifications (continued)<br />

Ambient conditions<br />

Operating temperature<br />

Operation<br />

(vertical installation)<br />

Storage/transport temperature<br />

0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °C<br />

Transport, storage<br />

Relative humidity<br />

-20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C<br />

max. relative humidity 90 % 90 % 90 % 90 %<br />

maximum permissible angle<br />

of inclination without external<br />

ventilation<br />

+/- 35 ° +/- 35 ° +/- 35 ° +/- 35 °<br />

Degree and class of<br />

protection<br />

Front IP65, NEMA 4, NEMA 12<br />

(when installed)<br />

2/164<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

IP65, NEMA 4, NEMA 12<br />

(when installed)<br />

IP65, NEMA 4, NEMA 12<br />

(when installed)<br />

Rear IP20 IP20 IP20 IP20<br />

Standards, approvals,<br />

certificates<br />

Certifications CE, FM Class I Div. 2,<br />

cULus, EX-Zone 22,<br />

C-TICK, NEMA 4, NEMA 12<br />

CE, cULus, C-TICK,<br />

NEMA 4, NEMA 12<br />

CE, FM Class I Div. 2,<br />

cULus, EX-Zone 22,<br />

C-TICK, NEMA 4, NEMA 12<br />

IP65, NEMA 4, NEMA 12<br />

(when installed)<br />

FM Class I Div. 2, cULus,<br />

EX-Zone 22, C-TICK,<br />

NEMA 4, NEMA 12<br />

Operating systems<br />

Operating system<br />

Configuration<br />

Configuration software<br />

Windows CE Windows CE Windows CE Windows CE<br />

Configuration tool<br />

Functionality under WinCC<br />

flexible/WinCC (portal)<br />

see "Configuration overview" from page 2/3<br />

Applications/options see chapter 4: HMI software/SIMATIC WinCC flexible options and SIMATIC WinCC (TIA portal) options<br />

Number of Visual Basic<br />

Scripts<br />

100 100 100 100<br />

Task planner Yes Yes Yes Yes<br />

Help system Yes Yes Yes Yes<br />

Status/control<br />

With alarm logging system<br />

(incl. buffer and acknowledgment)<br />

with SIMATIC S7 with SIMATIC S7 with SIMATIC S7 with SIMATIC S7<br />

Number of messages 4000 4 000 4000 4000<br />

Bit messages Yes Yes Yes Yes<br />

Analog messages Yes Yes Yes Yes<br />

Message buffer Ring buffer (n x 1024<br />

entries), retentive,<br />

maintenance-free<br />

Ring buffer (n x 1024<br />

entries), retentive,<br />

maintenance-free<br />

Ring buffer (n x 1024<br />

entries), retentive,<br />

maintenance-free<br />

Recipes<br />

Recipes 500 500 500 500<br />

Data records per recipe 1000 1 000 1000 1000<br />

Entries per data record 1000 1000 1000 1000<br />

Recipe memory 128 KB integrated Flash,<br />

expandable<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV6 644-0AA01-2AX0 6AV6 644-0BA01-2AX1 6AV6 644-0AB01-2AX0 6AV6 644-0AC01-2AX1<br />

Product type designation 12" Touch 12" Key 15" Touch 19" Touch<br />

128 KB integrated Flash,<br />

expandable<br />

128 KB integrated Flash,<br />

expandable<br />

Number of process images<br />

Process images 500 500 500 500<br />

Variables 2048 2 048 2048 2048<br />

Limit values Yes Yes Yes Yes<br />

Multiplexing Yes Yes Yes Yes<br />

Ring buffer (n x 1024<br />

entries), retentive,<br />

maintenance-free<br />

128 KB integrated Flash,<br />

expandable


© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Multi Panels — 370 series<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC MP 377<br />

■ Technical specifications (continued)<br />

6AV6 644-0AA01-2AX0 6AV6 644-0BA01-2AX1 6AV6 644-0AB01-2AX0 6AV6 644-0AC01-2AX1<br />

Product type designation<br />

Image elements<br />

12" Touch 12" Key 15" Touch 19" Touch<br />

Text objects 30,000 text elements 30,000 text elements 30,000 text elements 30,000 text elements<br />

Graphic object Bit maps, icons, vector Bit maps, icons, vector Bit maps, icons, vector Bit maps, icons, vector<br />

graphics<br />

graphics<br />

graphics<br />

graphics<br />

dynamic objects Diagrams, bar graphs, Diagrams, bar graphs, Diagrams, bar graphs, Diagrams, bar graphs,<br />

sliders, analog display, sliders, analog display, sliders, analog display, sliders, analog display,<br />

Lists<br />

invisible buttons<br />

invisible buttons<br />

invisible buttons<br />

invisible buttons<br />

Text lists 500 500 500 500<br />

Graphic list 500 500 500 500<br />

Libraries<br />

Archiving<br />

Yes Yes Yes Yes<br />

Number of archives per<br />

project<br />

50 50 50 50<br />

Number of measuring<br />

points per project<br />

50 50 50 50<br />

Number of entries per<br />

archive<br />

50 000 50 000 50 000 50 000<br />

Archiving types Sequence archive, short- Sequence archive, short- Sequence archive, short- Sequence archive, shortterm<br />

archive, alarm log, term archive, alarm log, term archive, alarm log, term archive, alarm log,<br />

process value archive process value archive process value archive process value archive<br />

Memory location CF card, SD/MMC card, CF card, SD/MMC card, CF card, SD/MMC card, CF card, SD/MMC card,<br />

Ethernet, USB memory Ethernet, USB memory Ethernet, USB memory Ethernet, USB memory<br />

stick<br />

stick<br />

stick<br />

stick<br />

Data storage format CSV file, readable, e.g. with CSV file, readable, e.g. with CSV file, readable, e.g. with CSV file, readable, e.g. with<br />

MS Excel, MS Access MS Excel, MS Access MS Excel, MS Access MS Excel, MS Access<br />

external evaluation Can be read, e.g., in MS Can be read, e.g., in MS Can be read, e.g., in MS Can be read, e.g., in MS<br />

Excel, MS Access, etc. Excel, MS Access, etc. Excel, MS Access, etc. Excel, MS Access, etc.<br />

Size of archive Depending on free memory Depending on free memory Depending on free memory Depending on free memory<br />

on ext. card/stick or on free on ext. card/stick or on free on ext. card/stick or on free on ext. card/stick or on free<br />

hard disk memory via hard disk memory via hard disk memory via hard disk memory via<br />

network drive<br />

network drive<br />

network drive<br />

network drive<br />

Online evaluation<br />

Security<br />

Using trend curves Using trend curves Using trend curves Using trend curves<br />

Number of user groups 50 50 50 50<br />

Passwords exportable Yes Yes Yes Yes<br />

Number of user rights<br />

Data carrier support<br />

32 32 32 32<br />

CF card Yes Yes Yes Yes<br />

Multimedia Card<br />

Recording<br />

Yes Yes Yes Yes<br />

Recording/Printing Alarms, report (shift report), Alarms, report (shift report), Alarms, report (shift report), Alarms, report (shift report),<br />

color print, hardcopy color print, hardcopy color print, hardcopy color print, hardcopy<br />

Printer driver<br />

Fonts<br />

ESC/P2, <strong>PC</strong>L3/<strong>PC</strong>L6 ESC/P2, <strong>PC</strong>L3/<strong>PC</strong>L6 ESC/P2, <strong>PC</strong>L3/<strong>PC</strong>L6 ESC/P2, <strong>PC</strong>L3/<strong>PC</strong>L6<br />

Keyboard fonts<br />

Languages<br />

US American (English) US American (English) US American (English) US American (English)<br />

Configuration languages D, GB, F, I, E, CHN "tradi- D, GB, F, I, E, CHN "tradi- D, GB, F, I, E, CHN "tradi- D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified", tional", CHN "simplified", tional", CHN "simplified", tional", CHN "simplified",<br />

DK, FIN, GR, J, KP / ROK, DK, FIN, GR, J, KP / ROK, DK, FIN, GR, J, KP / ROK, DK, FIN, GR, J, KP / ROK,<br />

NL, N, PL, P, RUS, S, CZ / NL, N, PL, P, RUS, S, CZ / NL, N, PL, P, RUS, S, CZ / NL, N, PL, P, RUS, S, CZ /<br />

SK, TR, H<br />

SK, TR, H<br />

SK, TR, H<br />

SK, TR, H<br />

Character sets Tahoma, Arial, Courier Tahoma, Arial, Courier Tahoma, Arial, Courier Tahoma, Arial, Courier<br />

New, symbol languages, New, symbol languages, New, symbol languages, New, symbol languages,<br />

4 additional character sets 4 additional character sets 4 additional character sets 4 additional character sets<br />

can be loaded, all freely can be loaded, all freely can be loaded, all freely can be loaded, all freely<br />

scalable<br />

scalable<br />

scalable<br />

scalable<br />

2/165<br />

2


2<br />

Operator panels<br />

Multi Panels — 370 series<br />

SIMATIC MP 377<br />

■ Technical specifications (continued)<br />

6AV6 644-0AA01-2AX0 6AV6 644-0BA01-2AX1 6AV6 644-0AB01-2AX0 6AV6 644-0AC01-2AX1<br />

Product type designation 12" Touch 12" Key 15" Touch 19" Touch<br />

Transfer (upload/download)<br />

Transfer of configuration MPI/PROFIBUS DP, serial,<br />

USB, Ethernet, by means of<br />

external storage medium,<br />

automatic transfer recognition<br />

2/166<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

MPI/PROFIBUS DP, serial,<br />

USB, Ethernet, by means of<br />

external storage medium,<br />

automatic transfer recognition<br />

MPI/PROFIBUS DP, serial,<br />

USB, Ethernet, by means of<br />

external storage medium,<br />

automatic transfer recognition<br />

Process coupling<br />

Connection to controller<br />

Expandability/openness<br />

see "System interface" from page 2/178<br />

Open Platform Program Yes Yes Yes Yes<br />

I/O<br />

I/O devices Printer, card reader,<br />

barcode reader<br />

Dimensions and weight<br />

Dimensions<br />

Printer, card reader,<br />

barcode reader<br />

Printer, card reader,<br />

barcode reader<br />

MPI/PROFIBUS DP, serial,<br />

USB, Ethernet, by means of<br />

external storage medium,<br />

automatic transfer recognition<br />

Printer, card reader,<br />

barcode reader<br />

Front of enclosure (W x H) 335 mm x 275 mm 483 mm x 310 mm 400 mm x 310 mm 483 mm x 400 mm<br />

Mounting cutout/device<br />

depth (W x H)<br />

310 mm x 248 mm / 72 mm<br />

device depth<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

450 mm x 290 mm / 59 mm<br />

device depth<br />

367 mm x 289 mm / 72 mm<br />

device depth<br />

Weight<br />

Weight 3.8 kg 5.5 kg 4.7 kg 7.7 kg<br />

449 mm x 379 mm / 75 mm<br />

device depth


■ Ordering data Order No. Order No.<br />

SIMATIC MP 377<br />

Multi Panel<br />

(including mounting accessories)<br />

with<br />

12" color TFT display, Touch E 6AV6 644-0AA01-2AX0<br />

12" color TFT display, Key E 6AV6 644-0BA01-2AX1<br />

15" color TFT display, Touch E 6AV6 644-0AB01-2AX0<br />

19" color TFT display, Touch<br />

Complete pre-assembled<br />

packages: SIMATIC MP 377 with<br />

WinAC MP 2007<br />

E 6AV6 644-0AC01-2AX1<br />

Package MP 377 12" Touch<br />

MP 377 12" Touch<br />

Single license for MP 377 on<br />

USB flash drive<br />

E 6AV6 652-4FC01-2AA0<br />

1)<br />

Standard Multimedia Card<br />

(empty)<br />

Package MP 377 12" Key<br />

MP 377 12" Key<br />

Single license for MP 377 on<br />

USB flash drive<br />

E 6AV6 652-4EC01-2AA0<br />

1)<br />

Standard Multimedia Card<br />

(empty)<br />

Package MP 377 15" Touch<br />

MP 377 15" Touch<br />

Single license for MP 377 on<br />

USB flash drive<br />

E 6AV6 652-4GC01-2AA0<br />

1)<br />

Standard Multimedia Card<br />

(empty)<br />

Package MP 377 19" Touch<br />

MP 377 19" Touch<br />

Single license for MP 377 on<br />

USB flash drive<br />

E 6AV6 652-4HC01-2AA0<br />

1)<br />

Standard Multimedia Card<br />

(empty)<br />

Configuration<br />

With SIMATIC WinCC flexible or<br />

SIMATIC WinCC<br />

Applications/options<br />

see HMI software<br />

When configuring with WinCC<br />

(TIA Portal)<br />

WinCC Sm@rtServer<br />

WinCC Audit<br />

WinCC MP 2008/software PLC<br />

see HMI software<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

1) Can only be used for license handling<br />

Operator panels<br />

Multi Panels — 370 series<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC MP 377<br />

Documentation<br />

(to be ordered separately)<br />

MP 377 Operating Instructions<br />

German 6AV6 691-1DR01-0AA0<br />

English 6AV6 691-1DR01-0AB0<br />

French 6AV6 691-1DR01-0AC0<br />

Italian 6AV6 691-1DR01-0AD0<br />

Spanish 6AV6 691-1DR01-0AE0<br />

WinCC flexible<br />

Compact/Standard/Advanced<br />

User Manual<br />

German 6AV6 691-1AB01-3AA0<br />

English 6AV6 691-1AB01-3AB0<br />

French 6AV6 691-1AB01-3AC0<br />

Italian 6AV6 691-1AB01-3AD0<br />

Spanish 6AV6 691-1AB01-3AE0<br />

User Manual<br />

WinCC flexible Communication<br />

German 6AV6 691-1CA01-3AA0<br />

English 6AV6 691-1CA01-3AB0<br />

French 6AV6 691-1CA01-3AC0<br />

Italian 6AV6 691-1CA01-3AD0<br />

Spanish 6AV6 691-1CA01-3AE0<br />

SIMATIC HMI Manual Collection B 6AV6 691-1SA01-0AX0<br />

Electronic documentation,<br />

on DVD<br />

5 languages (English, French,<br />

German, Italian and Spanish);<br />

contains: all currently available<br />

user manuals, manuals and<br />

communication manuals for<br />

SIMATIC HMI<br />

Accessories see HMI accessories<br />

2/167<br />

2


2<br />

Operator panels<br />

Multi Panels — 370 series<br />

SIMATIC MP 377<br />

■ Dimensional drawings<br />

All dimensions in mm. Tolerance ± 1 mm. Panel cutout see<br />

technical specifications.<br />

58<br />

MP 377 12" Key<br />

MP 377 12" Touch<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-multi-panels<br />

2/168<br />

335<br />

309<br />

483<br />

448<br />

300<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

275<br />

310<br />

288<br />

17<br />

247<br />

53<br />

20<br />

92<br />

59<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

32 10<br />

G_<strong>ST</strong><strong>80</strong>_XX_00309<br />

30 6<br />

72<br />

G_<strong>ST</strong><strong>80</strong>_XX_00310<br />

310<br />

MP 377 15" Touch<br />

54<br />

35<br />

MP 377 19" Touch<br />

483<br />

447<br />

295<br />

400<br />

366<br />

295<br />

73 38<br />

288<br />

30<br />

75<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.<br />

400<br />

378<br />

124<br />

77<br />

75<br />

6<br />

G_<strong>ST</strong><strong>80</strong>_XX_00311<br />

34 11<br />

G_<strong>ST</strong><strong>80</strong>_XX_00312


■ Overview<br />

WinAC MP, the software PLC based on Windows CE<br />

An optimized version is available for all current MP platforms<br />

The economical solution for all applications in combination<br />

with a rugged hardware platform<br />

Ideal for tasks on the machine level, saves space and costs<br />

Best service concept, backup/restore of all data on a standard<br />

SD card, standard Multi Media Card or standard USB stick<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Multi Panel options<br />

SIMATIC WinAC MP<br />

■ Application<br />

The WinAC MP is a new, rugged software PLC for all<br />

SIMATIC HMI Multi Panel platforms. It has been developed for<br />

smaller and medium-sized applications that do not depend on<br />

the last millisecond and costs are in the forefront.<br />

The WinAC uses familiar tools such as <strong>ST</strong>EP 7 V5.4 SP4 or higher<br />

and WinCC flexible as of 2008 SP1 Standard or WinCC Comfort<br />

V11 or higher. This makes it possible to upgrade or switch<br />

without any extra training for new tools.<br />

The I/Os are connected via PROFIBUS DP. Here, ET I/O modules<br />

up to technology modules are available.<br />

■ Design<br />

Versions<br />

Different WinAC MP versions are available. The versions define<br />

CPU performance classes.<br />

The versions are optimized for the Multi Panel platforms.<br />

These versions, namely WinAC MP 177 and 277 to 377, are<br />

based roughly on the hardware CPUs 314, 315 and 317. They<br />

have similar quantity frameworks but are not a 1:1 copy.<br />

All limit values, e.g. number of bit memories, DBs, FCs, I/Os,<br />

etc., are preset as with a hardware CPU and cannot be<br />

changed by the user. Detailed technical data is provided in<br />

the "Technical data" section.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/169<br />

2


2<br />

Operator panels<br />

Multi Panel options<br />

SIMATIC WinAC MP<br />

■ Function<br />

■ Programming<br />

The principle of operation and the instruction set of the<br />

Programming<br />

WinAC MP is basically identical to a hardware CPU. The settings<br />

for the WinAC MP-specific parameters are implemented by The programming in accordance with IEC 6 1131-3 and the<br />

means of the Hardware Config. Since WinAC MP and HMI appli- configuration of WinAC MP are performed using <strong>ST</strong>EP 7 V5.4<br />

cation share a processor, however, there is a special response SP4 (or higher) and the SIMATIC engineering tools for<br />

regarding the timing of the WinAC MP. All PLC commands are production engineering. Thus, all SIMATIC programming<br />

more quickly processed multiple times faster than on a hardware languages for WinAC MP are available as well.<br />

CPU, but this is required to created time reserves for the The SIMATIC programming languages comply with the standard<br />

HMI application. The potential for time optimization improves EN 6.1131-3. This reduces the familiarization and training<br />

with larger PLC programs. In WinAC MP 2008, a fixed<br />

overhead. CFC, SCL, as well as S7-Graf<br />

processing time must be set for HMI-RT, HMI options and<br />

communications. The default for this time is 50 ms. Users can<br />

change this time to achieve optimal performance of the application.<br />

In practice, this means an OB1 executes faster on a soft CPU<br />

and the time gained can be used for HMI Runtime. Another<br />

advantage of the WinAC MP is that the HMI application can<br />

always be interrupted by WinAC MP time and process alarms.<br />

Fast key response times can also be used with the implemented<br />

function "DP direct keys" with the WinAC MP. This provides<br />

another performance advantage of the WinAC MP.<br />

1) and ProAgent 1) are<br />

also supported.<br />

In addition, program modules that have been programmed for<br />

SIMATIC S7 hardware CPUs can be reused in WinAC MP without<br />

modifications as long as they were not designed for special<br />

features of a SIMATIC S7 CPU.<br />

1) Not with version WinAC MP 177.<br />

■ Integration<br />

I/Os<br />

The I/O can be connected via PROFIBUS DP. Standard components<br />

such as ET200 and the modules that can be used within<br />

are utilized. Diverse technological components can also be<br />

used with the ET200M in this constellation. In addition to normal<br />

standard ET I/Os, the following FM modules are released on the<br />

PROFIBUS:<br />

FM 350-1 counter module<br />

FM 350-2 counter module (8-channel)<br />

FM 351 positioning module<br />

FM 352 cam controller<br />

FM 355-2 temperature control module<br />

FM 352-5 high-speed Boolean processor<br />

FM 353 positioning module for stepper motors<br />

FM 354 positioning module for servo motors<br />

FM 355 closed-loop control module<br />

2/170<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Technical specifications<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

Multi Panel options<br />

SIMATIC WinAC MP<br />

6ES7 671-4EE00-0YA0 6ES7 671-5EF01-0YA0 6ES7 671-7EG01-0YA0<br />

Product type designation<br />

Memory<br />

Work memory<br />

WinAC MP 177 WinAC MP 277 WinAC MP 377<br />

integrated 128 Kibyte 256 Kibyte 512 Kibyte<br />

expandable<br />

Load memory<br />

No No No<br />

integrated RAM, max.<br />

CPU-blocks<br />

DB<br />

8Mbyte 8Mbyte 8Mbyte<br />

Number, max. 512; FBs+FCs+DBs=512 1 024; FBs+FCs+DBs=1024 2 048; FBs+FCs+DBs=2048<br />

Size, max.<br />

FB<br />

64 Kibyte 64 Kibyte 64 Kibyte<br />

Number, max. 512; FBs+FCs+DBs=512 1 024; FBs+FCs+DBs=1024 2 048; FBs+FCs+DBs=2048<br />

Size, max.<br />

FC<br />

64 Kibyte 64 Kibyte 64 Kibyte<br />

Number, max. 512; FBs+FCs+DBs=512 1 024; FBs+FCs+DBs=1024 2 048; FBs+FCs+DBs=2048<br />

Size, max.<br />

OB<br />

64 Kibyte 64 Kibyte 64 Kibyte<br />

Number, max. 18 18 18<br />

Size, max.<br />

Nesting depth<br />

64 Kibyte 64 Kibyte 64 Kibyte<br />

per priority class 8 8 16<br />

additional within an error OB<br />

Counters, timers and their<br />

retentivity<br />

S7 counter<br />

2 2 2<br />

Number<br />

of which retentive without battery<br />

128 256 512<br />

- can be set Yes Yes Yes<br />

-lower limit 0 0 0<br />

- upper limit<br />

Retentivity<br />

127 255 511<br />

- can be set Yes Yes Yes<br />

-preset<br />

Counting range<br />

8 8 8<br />

-lower limit 0 0 0<br />

- upper limit<br />

IEC counter<br />

999 999 999<br />

present<br />

S7 times<br />

Yes; SFB0, SFB1, SFB2 Yes; SFB0, SFB1, SFB2 Yes; SFB0, SFB1, SFB2<br />

Number<br />

of which retentive without battery<br />

128 256 512<br />

- can be set Yes Yes Yes<br />

-lower limit 0 0 0<br />

- upper limit<br />

Retentivity<br />

127 255 511<br />

- can be set Yes Yes Yes<br />

-preset<br />

Time range<br />

0 0 0<br />

-lower limit 10 ms 10 ms 10 ms<br />

- upper limit<br />

IEC timer<br />

9990s 9990s 9990s<br />

present<br />

Data areas and their retentivity<br />

Yes; SFB3, SFB4, SFB5 Yes; SFB3, SFB4, SFB5 Yes; SFB3, SFB4, SFB5<br />

retentive data area in total<br />

(incl. times, counters, flags), max.<br />

Flag<br />

64 Kibyte 128 Kibyte 256 Kibyte<br />

Number, max. 2Kibyte 2Kibyte 4Kibyte<br />

Retentivity available Yes Yes Yes<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/171<br />

2


2<br />

Operator panels<br />

Multi Panel options<br />

SIMATIC WinAC MP<br />

■ Technical specifications (continued)<br />

Data blocks<br />

Number, max. 512 1024 2048<br />

Size, max.<br />

Local data<br />

64 Kibyte 64 Kibyte 64 Kibyte<br />

per priority class, max.<br />

Address area<br />

I/O address area<br />

16 384 byte; for all priority classes 16 384 byte; for all priority classes 16 384 byte; for all priority classes<br />

Inputs 2Kibyte 4Kibyte 8Kibyte<br />

Outputs<br />

Process image<br />

2Kibyte 4Kibyte 8Kibyte<br />

Inputs 1Kibyte 2Kibyte 2Kibyte<br />

Outputs 1Kibyte 2Kibyte 2Kibyte<br />

Inputs, adjustable 1Kibyte 2Kibyte 2Kibyte<br />

Outputs, adjustable 1Kibyte 2Kibyte 2Kibyte<br />

Inputs, default 512 byte 512 byte 512 byte<br />

Outputs, default 512 byte 512 byte 512 byte<br />

consistent data, max.<br />

Hardware configuration<br />

Number of DP masters<br />

32 byte 32 byte 32 byte<br />

integrated<br />

Time of day<br />

Runtime meter<br />

1 1 1<br />

Number 8 8 8<br />

Number/Number range<br />

1st interface<br />

DP master<br />

0 to 7 0 to 7 0 to 7<br />

Number of connections, max.<br />

Services<br />

4 8 8<br />

- PG/OP communication Yes Yes Yes<br />

-Routing Yes Yes Yes<br />

- Global data communication No No No<br />

- S7 basic communication No No No<br />

- S7 communication Yes Yes Yes<br />

- Equidistance mode support No No No<br />

- SYNC/FREEZE Yes Yes Yes<br />

- Activation/deactivation of DP<br />

slaves<br />

Yes Yes Yes<br />

- DPV1 Yes Yes Yes<br />

Transmission rate, max. 12 Mbit/s 12 Mbit/s 12 Mbit/s<br />

Number of DP slaves, max.<br />

Address area<br />

32 32 32<br />

- Inputs, max. 2Kibyte 4Kibyte 8Kibyte<br />

- Outputs, max.<br />

Communication functions<br />

2Kibyte 4Kibyte 8Kibyte<br />

PG/OP communication Yes Yes Yes<br />

Routing<br />

Global data communication<br />

Yes Yes Yes<br />

supported<br />

S7 basic communication<br />

No No No<br />

supported No No No<br />

S7 communication<br />

supported Yes; PUT/GET, BSEND/BRCV,<br />

USEND/URCV<br />

2/172<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6ES7 671-4EE00-0YA0 6ES7 671-5EF01-0YA0 6ES7 671-7EG01-0YA0<br />

Product type designation WinAC MP 177 WinAC MP 277 WinAC MP 377<br />

as server Yes<br />

Yes; PUT/GET, BSEND/BRCV,<br />

USEND/URCV<br />

Yes Yes<br />

as client Yes Yes Yes<br />

User data per job, max. 4<strong>80</strong> byte 4<strong>80</strong> byte 4<strong>80</strong> byte<br />

Yes; PUT/GET, BSEND/BRCV,<br />

USEND/URCV


Operator panels<br />

Multi Panel options<br />

SIMATIC WinAC MP<br />

■ Technical specifications (continued)<br />

6ES7 671-4EE00-0YA0 6ES7 671-5EF01-0YA0 6ES7 671-7EG01-0YA0<br />

Product type designation WinAC MP 177 WinAC MP 277 WinAC MP 377<br />

Number of connections<br />

overall<br />

usable for PG communication<br />

8; (max. 8 DP, rest PROFINET) 16; (max. 8 DP, rest PROFINET) 32; (max. 8 DP, rest PROFINET)<br />

- reserved for PG communication<br />

usable for OP communication<br />

1 1 1<br />

- reserved for OP communication 1 1 1<br />

usable for routing 6 14 30<br />

Number of logical connections<br />

(also in network), max.<br />

S7 message functions<br />

8 16 32<br />

Process diagnostic messages Yes Yes Yes<br />

Test commissioning functions<br />

Status/control<br />

Status/control variable Yes; Status blocks, single step,<br />

breakpoint<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Yes; Status blocks, single step,<br />

breakpoint<br />

Yes; Status blocks, single step,<br />

breakpoint<br />

Forcing<br />

Forcing<br />

Diagnostic buffer<br />

No No No<br />

present Yes Yes Yes<br />

Number of entries, max. 1 000; preset 120 1 000; preset 120 1 000; preset 120<br />

- can be set<br />

Operating systems<br />

Yes Yes Yes<br />

Windows CE<br />

Configuration software<br />

Yes; Version 5.0 or higher Yes; Version 5.0 or higher Yes; Version 5.0 or higher<br />

<strong>ST</strong>EP 7 Yes; <strong>ST</strong>EP7 V5.4 SP4 or higher Yes; <strong>ST</strong>EP7 V5.4 SP4 or higher Yes; <strong>ST</strong>EP7 V5.4 SP4 or higher<br />

WinCC flexible Compact Yes; WinCC flexible 2008 SP1 No No<br />

WinCC flexible Standard Yes; WinCC flexible 2008 SP1 Yes; WinCC flexible 2008 SP1 Yes; WinCC flexible 2008 SP1<br />

WinCC flexible Advanced<br />

programming<br />

Programming language<br />

Yes; WinCC flexible 2008 SP1 Yes; WinCC flexible 2008 SP1 Yes; WinCC flexible 2008 SP1<br />

-LAD Yes Yes Yes<br />

-FBD Yes Yes Yes<br />

-<strong>ST</strong>L Yes Yes Yes<br />

-SCL Yes Yes Yes<br />

-CFC Yes Yes Yes<br />

Software libraries<br />

- Process diagnostics Yes; System error messages Yes; System error messages,<br />

ProAgent (S7-Graph)<br />

Cycle time monitoring<br />

can be set Yes Yes Yes<br />

preset<br />

Online languages<br />

6000ms 6000ms 6000ms<br />

Number 1; English 1; English 1; English<br />

Yes; System error messages,<br />

ProAgent (S7-Graph)<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/173<br />

2


2<br />

Operator panels<br />

Multi Panel options<br />

SIMATIC WinAC MP<br />

■ Ordering data Order No. Order No.<br />

WinAC MP,<br />

version WinAC MP 177 2)<br />

incl. a Single License for MP 177<br />

on USB stick<br />

6ES7 671-4EE00-0YA0<br />

1) and electronic<br />

documentation<br />

WinAC MP,<br />

version WinAC MP 277 2)<br />

incl. a Single License for MP 277<br />

on USB stick<br />

6ES7 671-5EF01-0YA0<br />

1) and electronic<br />

documentation<br />

WinAC MP,<br />

version WinAC MP 377 2)<br />

incl. a Single License for MP 377<br />

on USB stick<br />

6ES7 671-7EG01-0YA0<br />

1) and electronic<br />

documentation<br />

Complete pre-assembled<br />

packages<br />

Package MP 177 6" Touch<br />

MP 177 6" Touch<br />

WinAC MP Version 177<br />

Electronic documentation<br />

Single License for MP 177 on<br />

USB flash drive<br />

E 6AV6 652-2JC01-2AA0<br />

1)<br />

Standard SD card 256 MB<br />

(empty)<br />

Package MP 277 8" Touch<br />

MP 277 8" Touch<br />

WinAC MP Version 277<br />

Electronic documentation<br />

Single License for MP 277 on<br />

USB stick<br />

E 6AV6 652-3MC01-1AA0<br />

1)<br />

Standard SD card 256 MB<br />

(empty)<br />

Package MP 277 8" Key<br />

MP 277 8" Key<br />

WinAC MP Version 277<br />

Electronic documentation<br />

Single License for MP 277 on<br />

USB stick<br />

E 6AV6 652-3LC01-1AA0<br />

1)<br />

Standard SD card 256 MB<br />

(empty)<br />

Package MP 277 10" Touch<br />

MP 277 10" Touch<br />

WinAC MP Version 277<br />

Electronic documentation<br />

Single License for MP 277 on<br />

USB stick<br />

E 6AV6 652-3<strong>PC</strong>01-1AA0<br />

1)<br />

Standard SD card 256 MB<br />

(empty)<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

2/174<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Package MP 277 10" Key<br />

MP 277 10" Key<br />

WinAC MP Version 277<br />

Electronic documentation<br />

Single License for MP 277 on<br />

USB stick<br />

E 6AV6 652-3NC01-1AA0<br />

1)<br />

Standard SD card 256 MB<br />

(empty)<br />

Package MP 377 12" Touch<br />

MP 377 12" Touch<br />

WinAC MP Version 377<br />

Electronic documentation<br />

Single License for MP 377 on<br />

USB stick<br />

E 6AV6 652-4FC01-2AA0<br />

1)<br />

Standard SD card 256 MB<br />

(empty)<br />

Package MP 377 12" Key<br />

MP 377 12" Key<br />

WinAC MP Version 377<br />

Electronic documentation<br />

Single License for MP 377 on<br />

USB stick<br />

E 6AV6 652-4EC01-2AA0<br />

1)<br />

Standard SD card 256 MB<br />

(empty)<br />

Package MP 377 15" Touch<br />

MP 377 15" Touch<br />

WinAC MP Version 377<br />

Electronic documentation<br />

Single License for MP 377 on<br />

USB stick<br />

E 6AV6 652-4GC01-2AA0<br />

1)<br />

Standard SD card 256 MB<br />

(empty)<br />

Package MP 377 19" Touch<br />

MP 377 19" Touch<br />

WinAC MP Version 377<br />

Electronic documentation<br />

Single License for MP 377 on<br />

USB stick<br />

E 6AV6 652-4HC01-2AA0<br />

1)<br />

Standard SD card 256 MB<br />

(empty)<br />

1) Can only be used for license handling<br />

2) UCL version on request


■ Overview<br />

Multi Panels (MP) are deployed on-site – like Operator<br />

Panels – for machine operation and monitoring<br />

The buffer content and the retentive WinAC MP data remain<br />

even when the panels are off and no battery is present<br />

PLC functionality can be directly integrated into the MP 177<br />

platform using option<br />

Multi Panels can be fully expanded through the Sm@rtService<br />

and Sm@rtAccess options<br />

Full graphics 5.7" TFT display, color (64k colors)<br />

All interfaces onboard such as MPI, PROFIBUS DP, USB,<br />

PROFINET (Ethernet TCP/IP)<br />

The MP 177 6" Touch is also delivered with a WinAC MP 177 as<br />

a package. WinCC flexible 2008 SP1 Compact, Standard, or<br />

Advanced is required for the configuration of the MP 177.<br />

Note:<br />

SIPLUS extreme products are based on <strong>Siemens</strong> Industry<br />

standard products. The contents listed here were taken from the<br />

respective standard products. SIPLUS extreme-specific information<br />

was added.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

SIPLUS Multi Panels for 170 series<br />

SIPLUS HMI MP 177<br />

SIPLUS HMI MP 177<br />

Order No. 6AG1 642-0BD01-4AX0<br />

Order No. based on 6AV6 642-0EA01-3AX0<br />

Ambient temperature range 0 ... + 50 °C<br />

Conformal coating Coating of the printed circuit<br />

boards and the electronic<br />

components<br />

Technical data The technical data of the<br />

standard product applies except<br />

for the ambient conditions.<br />

Ambient conditions<br />

Relative humidity 5 ... 100 %<br />

Condensation permissible<br />

Biologically active substances Conformity with EN 60721-3-3,<br />

Class 3B2 mold and fungal<br />

spores (except fauna)<br />

Chemically active substances Conformity with EN 60721-3-3,<br />

Class 3C4 incl. salt mist and ISA–<br />

S71.04 severity level G1; G2; G3;<br />

1) 2) GX<br />

Mechanically active substances Conformity with EN 60721-3-3,<br />

Class 3S4 including conductive<br />

sand, dust 2)<br />

Air pressure (depending on the 10<strong>80</strong> ... 795 hPa<br />

highest positive temperature range (-1000 ... +2000 m)<br />

specified)<br />

see ambient temperature range<br />

795 ... 658 hPa<br />

(+2000 ... +3500 m)<br />

derating 10 K<br />

658 ... 540 hPa<br />

(+3500 ... +5000 m)<br />

derating 20 K<br />

1) ISA-S71.04 severity level GX: Long-term load: SO2 < 4.8 ppm;<br />

H2S


2<br />

Operator panels<br />

SIPLUS Multi Panels for 270 series<br />

SIPLUS HMI MP 277<br />

■ Overview<br />

Multi Panels (MP) are deployed on-site – like Operator<br />

Panels – for machine operation and monitoring<br />

The buffer content remains even when the panels are off and<br />

no battery is present<br />

PLC functionality can be directly integrated into the MP 277<br />

platform using option<br />

They can extend their functionality through the installation of<br />

additional Windows CE applications (multi-panel and panel<br />

options)<br />

The SIMATIC MP 277 combine on the basis of Windows CE the<br />

ruggedness of operator panels with the flexibility of <strong>PC</strong>s<br />

Full graphics 7.5" or 10.4" TFT display, color (64k colors)<br />

MP 277 8" and MP 277 10" Touch:<br />

Touchscreen (analog/resistive)<br />

MP 277 8" Key:<br />

38 system keys, 26 freely-configurable and freely-inscribable<br />

function keys (18 with LED)<br />

MP 277 10" Key:<br />

38 system keys, 36 freely-configurable and freely-inscribable<br />

function keys (28 with LEDs)<br />

The MP 277 is also available with a stainless steel front, and<br />

thus meets the higher requirements of e.g. the food and<br />

beverage industry.<br />

All interfaces onboard such as MPI, PROFIBUS DP, USB,<br />

PROFINET (Ethernet TCP/IP)<br />

Note:<br />

SIPLUS extreme products are based on <strong>Siemens</strong> Industry<br />

standard products. The contents listed here were taken from the<br />

respective standard products. SIPLUS extreme-specific information<br />

was added.<br />

2/176<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIPLUS HMI MP 277<br />

Order No. 6AG1 643-0CD01-4AX1<br />

Order No. based on 6AV6 643-0CD01-1AX1<br />

Ambient temperature range 0 ... + 50 °C<br />

Conformal coating Coating of the printed circuit<br />

boards and the electronic<br />

components<br />

Technical data The technical data of the<br />

standard product applies except<br />

for the ambient conditions.<br />

Ambient conditions<br />

Relative humidity 5 ... 100 %<br />

Condensation permissible<br />

Biologically active substances Conformity with EN 60721-3-3,<br />

Class 3B2 mold and fungal<br />

spores (except fauna)<br />

Chemically active substances Conformity with EN 60721-3-3,<br />

Class 3C4 incl. salt mist and<br />

ISA–S71.04 severity level G1; G2;<br />

1) 2)<br />

G3; GX<br />

Mechanically active substances Conformity with EN 60721-3-3,<br />

Class 3S4 including conductive<br />

sand, dust 2)<br />

Air pressure (depending on the 10<strong>80</strong> ... 795 hPa<br />

highest positive temperature range (-1000 ... +2000 m)<br />

specified)<br />

see ambient temperature range<br />

795 ... 658 hPa<br />

(+2000 ... +3500 m)<br />

derating 10 K<br />

658 ... 540 hPa<br />

(+3500 ... +5000 m)<br />

derating 20 K<br />

1) ISA-S71.04 severity level GX: Long-term load: SO2 < 4.8 ppm;<br />

H2S


■ Overview<br />

Multi Panels (MP) are deployed on-site – like Operator Panels<br />

– for machine operation and monitoring<br />

They can extend their functionality through the installation of<br />

additional Windows CE applications (multi-panel and panel<br />

options)<br />

The SIMATIC MP 377 combine on the basis of Windows CE the<br />

ruggedness of operator panels with the flexibility of <strong>PC</strong>s<br />

PLC functionality can be directly integrated into the MP 377<br />

platform using option<br />

Operator panels<br />

SIPLUS Multi Panels for 370 series<br />

SIPLUS HMI MP 377<br />

Full graphics 12.1" or 15" or 19" TFT display, color (64k colors)<br />

MP 377 12" Touch, MP 377 15" Touch and MP 377 19" Touch:<br />

Touchscreen (analog/resistive)<br />

MP 377 12" Keys:<br />

38 system keys, 36 freely-configurable and freely-inscribable<br />

function keys (36 with LEDs)<br />

SIMATIC MP 377 PRO 15" Touch:<br />

Featuring a robust and very compact aluminum housing, it is<br />

completely IP65 protected and therefore suitable for harsh<br />

ambient conditions.<br />

All interfaces onboard such as MPI, PROFIBUS DP, USB,<br />

PROFINET (Ethernet TCP/IP)<br />

SIMATIC MP 377 INOX 15" Touch (stainless steel front):<br />

The MP 377 15" Touch is also available with a stainless steel<br />

front (EN 1672-2) and as a fully enclosed HMI (IP65). The<br />

versions extend the range of the Multi Panels 377 for special<br />

applications, ambient conditions, and for specific industries<br />

(e.g. food, beverages, and tobacco industry).<br />

Note:<br />

SIPLUS extreme products are based on <strong>Siemens</strong> Industry<br />

standard products. The contents listed here were taken from the<br />

respective standard products. SIPLUS extreme-specific information<br />

was added.<br />

SIPLUS HMI MP 377 12“ Color-TFT-Display, Touch 15“ Color-TFT-Display, Touch<br />

Order No. 6AG1 644-0AA01-4AX0 6AG1 644-0AB01-4AX0<br />

Order No. based on 6AV6 644-0AA01-2AX0 6AV6 644-0AB01-2AX0<br />

Ambient temperature range 0 ... + 50 °C<br />

Conformal coating Coating of the printed circuit boards and the electronic components<br />

Technical data<br />

Ambient conditions<br />

The technical data of the standard product applies except for the ambient conditions.<br />

Relative humidity 5...100%<br />

Condensation permissible<br />

Biologically active substances Conformity with EN 60721-3-3, Class 3B2 mold and fungal spores (except fauna)<br />

Chemically active substances Conformity with EN 60721-3-3, Class 3C4 incl. salt mist and ISA–S71.04 severity level G1; G2;<br />

G3; GX 1) 2)<br />

Mechanically active substances Conformity with EN 60721-3-3, Class 3S4 including conductive sand, dust 2)<br />

Air pressure (depending on the highest positive 10<strong>80</strong> ... 795 hPa (-1000 ... +2000 m) see ambient temperature range<br />

temperature range specified)<br />

795 ... 658 hPa (+2000 ... +3500 m) derating 10 K<br />

658 ... 540 hPa (+3500 ... +5000 m) derating 20 K<br />

1) ISA-S71.04 severity level GX: Long-term load: SO 2 < 4.8 ppm; H 2 S


2<br />

Operator panels<br />

System interfaces with WinCC flexible<br />

System interfaces with WinCC flexible<br />

■ Overview<br />

SIMATIC Basic Panel, Touch Panels (TP), Operator Panels (OP),<br />

Mobile Panel, Multifunctional Platforms (MP) 1) and the<br />

SIMATIC HMI software package for <strong>PC</strong> WinCC flexible Runtime<br />

support HMI functionality in conjunction with:<br />

SIMATIC S7<br />

SIMATIC S5<br />

SIMATIC 505<br />

SIMOTION<br />

SINUMERIK 2)<br />

Non-<strong>Siemens</strong> controllers:<br />

- Allen Bradley - DF1, DH485 and Ethernet IP protocols<br />

- GE Fanuc - SNP/SNPX protocol<br />

- LG GLOFA GM - dedicated protocol<br />

- Mitsubishi - FX and MP 4 protocols<br />

- Modicon - Modbus RTU and TCP/IP protocols<br />

- Omron I - Link/MultiLink protocol<br />

- Telemecanique - UNI-TELWAY protocol<br />

For more detailed information, refer to the WinCC flexible user<br />

manual, the "Windows-based systems communication" manual,<br />

and the WinCC flexible online help.<br />

1) For the sake of simplicity, SIMATIC TP/OP/MP is always used in the text<br />

below. This is not restrictive, as the information is valid for all systems<br />

referred to above. If there are constraints, direct reference is made to<br />

them in the text.<br />

2) Required under WinCC flexible: "SINUMERIK HMI copy license<br />

WinCC flexible CE" and "SINUMERIK HMI copy license OA".<br />

For configuring, a "SINUMERIK HMI engineering package<br />

WinCC flexible" is also necessary.<br />

Note:<br />

Interface options for HMI devices: See the individual device<br />

descriptions.<br />

Communication standard SIMATIC HMI<br />

Version TP 177B DP/PN<br />

OP 177B DP/PN<br />

Mobile Panel<br />

177 PN<br />

MP 177<br />

O<strong>PC</strong> Data Access V2.05a + O<strong>PC</strong> Data Access XML V1.00<br />

O<strong>PC</strong> client<br />

(COM/DCOM)<br />

O<strong>PC</strong> server<br />

(COM/DCOM)<br />

O<strong>PC</strong> XML client<br />

(SOAP/XML)<br />

O<strong>PC</strong> XML server<br />

(SOAP/XML)<br />

System interface possible<br />

– System interface not possible<br />

1) Option WinCC flexible /O<strong>PC</strong> Server for WinCC flexible Runtime<br />

required<br />

2) Only with DCOM/XML gateway included in the scope of delivery of<br />

WinCC flexible for access to MP 277, MP 377 and MP 370 O<strong>PC</strong><br />

XML servers<br />

3) Option WinCC flexible /O<strong>PC</strong> Server for SIMATIC Multi Panel required<br />

2/178<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

TP 277<br />

OP 277<br />

Extended functionality with WinCC flexible<br />

WinCC flexible supports O<strong>PC</strong> communication for Multi Panel<br />

and WinCC flexible Runtime and HTTP communication for all<br />

panels with integrated Ethernet interface. Both O<strong>PC</strong> and HTTP<br />

communication can be used in parallel with the process links to<br />

SIMATIC S7/S5/505 or non-<strong>Siemens</strong> PLCs.<br />

O<strong>PC</strong> Data Access (MP 277, MP 377, WinCC flexible Runtime<br />

only)<br />

O<strong>PC</strong> Data Access is an open standard for exchanging both local<br />

and remote variables between various applications via Industrial<br />

Ethernet. The original version of O<strong>PC</strong> is based on Microsoft<br />

COM/DCOM and, therefore, requires a Microsoft Windowsbased<br />

<strong>PC</strong> operating system (not Windows CE) on both clients<br />

and servers. As O<strong>PC</strong> XML, communication is based on the<br />

Internet standard SOAP/XML and is, therefore, suitable for<br />

embedded systems with Windows CE.<br />

Options that are required: WinCC flexible/ O<strong>PC</strong> server<br />

HTTP communication for the variable exchange between<br />

SIMATIC HMI systems<br />

(only TP 177B DP/PN, OP 177B DP/PN, Mobile Panel 177 PN,<br />

TP 277, OP 277, Mobile Panel 277, Mobile Panel 277 IWLAN,<br />

MP 277, MP 377, WinCC flexible Runtime)<br />

Communication based on HTTP message frames enables<br />

variables to be exchanged between SIMATIC HMI systems.<br />

Options that are required:<br />

WinCC flexible/ Sm@rt Access<br />

Mobile Panel 277 6)<br />

Mobile Panel<br />

277 IWLAN<br />

MP 277<br />

MP 377<br />

WinCC flexible<br />

Runtime<br />

Connection via<br />

– – – Industrial Ethernet<br />

(see <strong>Catalog</strong> IK PI)<br />

– – – 1) Industrial Ethernet<br />

(see <strong>Catalog</strong> IK PI)<br />

– – – 2) Industrial Ethernet<br />

(see <strong>Catalog</strong> IK PI)<br />

– – 3) – Industrial Ethernet<br />

(see <strong>Catalog</strong> IK PI)<br />

HTTP communication for variable exchange between SIMATIC HMI systems<br />

HTTP client 4) 4) 4) 5) Industrial Ethernet<br />

(see <strong>Catalog</strong> IK PI)<br />

HTTP server 4) 4) 4) 5) Industrial Ethernet<br />

(see <strong>Catalog</strong> IK PI)<br />

4) Option WinCC flexible /Sm@rtAccess for SIMATIC Panel required<br />

5) Option WinCC flexible /Sm@rtAccess for WinCC flexible Runtime<br />

required<br />

6) Depending on the terminal box used


■ Overview<br />

The following types of interface are supported in respect of the<br />

link between SIMATIC HMI Panels and SIMATIC WinCC flexible<br />

Runtime with SIMATIC S7:<br />

PPI interface:<br />

Interface between SIMATIC HMI Panels and SIMATIC S7-200<br />

via PPI. Communication runs on the PPI protocol, a standard<br />

FB as with SIMATIC S5 is not required.<br />

MPI interface:<br />

Interface between SIMATIC HMI Panels and SIMATIC S7 via<br />

the integrated PPI interface with S7-200 or MPI interface with<br />

S7-300/-400 or alternatively via the MPI interface of a separate<br />

interface module and the backplane bus to the<br />

SIMATIC S7-CPU. Communication runs on the MPI protocol<br />

(PG/OP communication), a standard FB as with SIMATIC S5 is<br />

not required.<br />

PROFIBUS interface:<br />

Interface between SIMATIC HMI Panels and SIMATIC S7 via<br />

the integrated PROFIBUS interface on the CPU or alternatively<br />

via the PROFIBUS interface on a separate interface module<br />

and the backplane bus to the SIMATIC S7-CPU.<br />

Communication runs on the MPI protocol (PG/OP<br />

communication), a standard FB as with SIMATIC S5 is not<br />

required.<br />

PROFINET interface:<br />

Interface between SIMATIC HMI Panels and SIMATIC S7 via<br />

the integrated PROFINET interface on the CPU or alternatively<br />

via the Industrial Ethernet interface on a separate interface<br />

module and the backplane bus to the SIMATIC S7-CPU.<br />

Communication runs on the MPI protocol (PG/OP<br />

communication), a standard FB as with SIMATIC S5 is not<br />

required.<br />

The maximum possible number of S7 connections of a CPU is<br />

determined by its power (see <strong>Catalog</strong> <strong>ST</strong> 70); from the point of<br />

view of SIMATIC HMI Panels the following restrictions apply:<br />

OP 73micro, TP 177micro: 1 connection<br />

OP 73: max. 2 connections<br />

OP 77A, TP 177A, Basic Panel, OP 77B, TP 177B, OP 177B,<br />

Mobile Panel 177: max. 4 connections<br />

TP 277, OP 277; Mobile Panel 277, MP 177, MP 277, MP 377:<br />

max. 6 connections<br />

<strong>PC</strong> with WinCC flexible Runtime: max. 8 connections<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

System interfaces with WinCC flexible<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC S7<br />

PPI interface<br />

From the point of view of the concept, the PPI interface is a pointto-point<br />

connection between a SIMATIC HMI Panel (PPI master)<br />

or alternatively a PG (PPI master), and a S7-200 (PPI slave).<br />

MPI interface/PROFIBUS interface/Industrial Ethernet<br />

interface<br />

The multipoint-enabled communication interfaces of<br />

SIMATIC HMI Panels and SIMATIC S7 are used. Options are:<br />

Interface between one or a number of SIMATIC HMI Panels<br />

(MPI master) and one or a number of S7-1200/300/400s or<br />

WinAC (MPI master).<br />

(possible network topology:<br />

MPI/PROFIBUS/Industrial Ethernet)<br />

Interface between<br />

one or a number of SIMATIC HMI Panels (MPI master)<br />

and one or a number of S7-200s (MPI slave) 1)<br />

(possible network topology: PPI/MPI/PROFIBUS)<br />

Unlike PPI connections, MPI connections are static connections<br />

that are set up during booting and then monitored.<br />

The original format of a master/master link has in the meantime<br />

been joined by a master/slave link, which has enabled<br />

integration of the S7-200 (except CPU 212). 1)<br />

In principle, this type of information exchange between<br />

SIMATIC HMI Panel and SIMATIC S7 is independent of the<br />

network used, PPI, MPI, PROFIBUS or Industrial Ethernet:<br />

SIMATIC HMI Panels are S7 clients and SIMATIC S7 CPUs are<br />

S7 servers.<br />

1) Constraints with regard to baud rate for S7-200; see <strong>Catalog</strong> <strong>ST</strong> 70.<br />

2/179<br />

2


2<br />

Operator panels<br />

System interfaces with WinCC flexible<br />

SIMATIC S7<br />

■ Overview (continued)<br />

Controller SIMATIC HMI<br />

Target hardware (PROTOCOL)<br />

(physics)<br />

System interface possible<br />

– System interface not possible<br />

1) TD series can only be interfaced with max. 1 x S7-200 via PPI<br />

(PPI/MPI); network operation (parallel PG, etc.) possible; max. data<br />

transfer rate 187.5 kbit/s; cable included in scope of supply<br />

2) OP 73micro, TP 177 micro can only be interfaced with max. 1 x S7-200<br />

(MPI); network operation (parallel PG, etc.) possible; max. data<br />

transfer rate 187.5 kbit/s<br />

3) OP 73 can only be interfaced with max. 2 x SIMATIC S7 (MPI); network<br />

operation (parallel PG, etc.) possible; max. data transfer rate<br />

1.5 Mbit/s<br />

4) Max. transmission rate 1.5 Mbit/s<br />

5) MPI cable 6ES7 901-0BF00-0AA0 (max. 187.5 Kbit/s) included in<br />

PG scope of delivery<br />

6) Bus connector 6GK1 500-0EA02<br />

2/1<strong>80</strong><br />

TD 100C<br />

TD 200<br />

TD 200C<br />

TD 400C<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

OP 73 micro<br />

TP 177micro<br />

OP 73 OP 77A<br />

TP 177A<br />

Connection via<br />

SIMATIC S7 (PPI/MPI)<br />

via PPI on S7-200 (PPI) • 1) – – – MPI cable 5)<br />

via MPI or PROFIBUS<br />

(PG/OP communication)<br />

with S7-200<br />

via MPI or PROFIBUS<br />

(PG/OP communication)<br />

with S7-300, -400<br />

via PPI network (PPI)<br />

with max. 1 x S7-200<br />

via PPI network<br />

(PG/OP communication)<br />

with max. 4 x S7-200<br />

via MPI or PROFIBUS network<br />

(PG/OP communication)<br />

with max. 4 x S7-200<br />

via MPI or PROFIBUS network<br />

(PG/OP communication)<br />

with max. 4 x S7-300, -400, WinAC<br />

via Industrial Ethernet (TCP/IP)<br />

(PG/OP communication)<br />

with max. 4 x S7-200, -300, -400,<br />

WinAC<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

– • 2) • 3) • 4) MPI cable 5)<br />

– – • 3) • 4) MPI cable 5)<br />

• 1) – – – PPI network 6)<br />

(see <strong>Catalog</strong>s <strong>ST</strong> 70 and IK PI)<br />

• 1) • 2) • 3) • 4) PPI network 6)<br />

(see <strong>Catalog</strong>s <strong>ST</strong> 70 and IK PI)<br />

– • 2) • 3) • 4) MPI or PROFIBUS network 6)<br />

(see <strong>Catalog</strong>s <strong>ST</strong> 70 and IK PI)<br />

– – • 3) • 4) MPI or PROFIBUS network 6)<br />

(see <strong>Catalog</strong>s <strong>ST</strong> 70 and IK PI)<br />

– – – – Industrial Ethernet<br />

(see <strong>Catalog</strong> IK PI)


■ Overview (continued)<br />

Controller SIMATIC HMI<br />

Target hardware (PROTOCOL)<br />

(physics)<br />

System interface possible<br />

– System interface not possible<br />

Basic Panels OP 77B<br />

TP 177B DP<br />

OP 177B DP<br />

TP 177B DP/PN<br />

OP 177B DP/PN<br />

Mobile Panel 177 DP<br />

Mobile Panel 177 PN<br />

1) Can only be interfaced with max. 1 x S7-200 via PPI (PPI); network<br />

operation (parallel PG, etc.) possible<br />

2) Not Basic Panel PN, Mobile Panel 177 PN, Mobile Panel 277 IWLAN;<br />

Mobile Panel 177 DP, Mobile Panel 277 connection via special<br />

connecting cable and terminal box (see Mobile Panel);<br />

Please refer to the manual for cable assignment<br />

3)<br />

Connection via integrated MPI/PROFIBUS interface; use of<br />

CP 5611 A2 with a standard <strong>PC</strong>.<br />

4) Max. transmission rate 1.5 Mbit/s<br />

5) Only on passive S7-200; OP 77B (MPI) also on active S7-200<br />

6) Only OP 77B (MPI)<br />

7) Only Basic Panel PN, TP 177B DP/PN, OP 177B DP/PN,<br />

Mobile Panel 177 PN<br />

8)<br />

Mobile Panel 177 PN, Mobile Panel 277 connection via special<br />

connecting cable and terminal box (see Mobile Panel);<br />

Please refer to the manual for cable assignment<br />

9) Mobile Panel 277 IWLAN (wireless interface, see Mobile Panel)<br />

10) Connection via integrated Industrial Ethernet interface; use the<br />

CP 1612 with a standard <strong>PC</strong><br />

11) MPI cable 6ES7 901-0BF00-0AA0 (max. 187.5 Kbit/s) included in<br />

PG scope of delivery (for download and test purposes only)<br />

12) Bus connector 6GK1 500-0EA02<br />

Operator panels<br />

System interfaces with WinCC flexible<br />

TP 277<br />

OP 277<br />

Mobile Panel 277<br />

Mobile Panel 277<br />

IWLAN<br />

MP 177<br />

MP 277<br />

MP 377<br />

WinCC<br />

flexible<br />

Runtime<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC S7<br />

Connection via<br />

via PPI on S7-200 (PPI) – • 1) 2) • 1) 2) • 1) 3) MPI cable 11)<br />

via MPI or PROFIBUS<br />

(PG/OP communication)<br />

on S7-200<br />

via MPI or PROFIBUS<br />

(PG/OP communication)<br />

with S7-300, -400<br />

via PPI network (PPI)<br />

with max. 1 x S7-200<br />

via PPI network<br />

(PG/OP communication)<br />

with max. 4 x S7-200<br />

via MPI or PROFIBUS network<br />

(PG/OP communication)<br />

with max. 4 x S7-200<br />

via MPI or PROFIBUS network<br />

(PG/OP communication)<br />

with max. 4 x S7-300, -400, WinAC<br />

via Industrial Ethernet (TCP/IP)<br />

(PG/OP communication)<br />

with max. 4 x S7-200, -300, -400,<br />

WinAC<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

• 2) • 2) 5) • 2) 5) • 3) 5) MPI cable 11)<br />

• 2) • 2) • 2) • 3) MPI cable 11)<br />

– • 1) 2) • 1) 2) • 1) 3) PPI network 12)<br />

(see <strong>Catalog</strong> <strong>ST</strong> 70<br />

and IK PI)<br />

• 2) • 6) – – PPI network 12)<br />

(see <strong>Catalog</strong> <strong>ST</strong> 70<br />

and IK PI)<br />

• 2) • 2) 5) • 2) 5) • 3) 5) MPI or PROFIBUS<br />

network 12)<br />

(see <strong>Catalog</strong>s <strong>ST</strong> 70<br />

and IK PI)<br />

• 2) • 2) • 2) • 3) MPI or PROFIBUS<br />

network 12)<br />

(see <strong>Catalog</strong>s <strong>ST</strong> 70<br />

and IK PI)<br />

– 7) • 7) 8) • 8) 9) • 10) Industrial Ethernet<br />

(see <strong>Catalog</strong> IK PI)<br />

2/181<br />

2


2<br />

Operator panels<br />

System interfaces with WinCC flexible<br />

SIMATIC S5<br />

■ Overview<br />

A variety of interfaces differing in respect of type and performance<br />

are available for linking SIMATIC HMI Panels to<br />

SIMATIC S5 (not S5-150U). However, a feature common to all is<br />

that from the point of view of the connected SIMATIC HMI Panel,<br />

the connection is always a logical point-to-point one, i.e. there is<br />

always a fixed assignment between a SIMATIC HMI Panel and a<br />

PLC.<br />

AS511 interface (not for OP 77A, TP 177A, Basic Panel,<br />

Mobile Panel 177, Mobile Panel 277)<br />

S5-90U to -135U, -155U (except CPU 922 < Version 9,<br />

except CPU 928 [6ES5 928-3UA11], except CPU 946/947<br />

[6ES5 94 -3UA11], except CPU 946/947 [6ES5 94 -3UA21],<br />

except CPU 946/947 [6ES5 94 -3UA22] < Version 5)<br />

The AS511 interface is implemented via the PG interface of<br />

SIMATIC S5 and uses the associated CPU resources, that is, the<br />

performance capability of the SIMATIC HMI Panel is determined<br />

by the performance capability of the SIMATIC CPU used.<br />

2/182<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

PROFIBUS DP interface (not for OP 77A, TP 177A,<br />

Basic Panel, Mobile Panel 177 PN, Mobile Panel 277 IWLAN)<br />

S5-115U, -135U, -155U via IM 308C or CP 5431 FMS/ DP<br />

(except CPU 922 < Version 9, except CPU 928<br />

[6ES5 928-3UA11], except CPU 946/947 [6ES5 94 -3UA11],<br />

except CPU 946/947 [6ES5 94 -3UA21], except CPU 946/947<br />

[6ES5 94 -3UA22] < Version 5)<br />

The PROFIBUS DP interface supports the connection of:<br />

Up to 2 SIMATIC HMI Panels as SLAVES via a PROFIBUS<br />

network to a SIMATIC S5-95U with integrated<br />

PROFIBUS DP/master interface [6ES5 095-8ME01]<br />

Up to 30 SIMATIC HMI Panels as SLAVES via a PROFIBUS<br />

network to a SIMATIC S5 with separate PROFIBUS DP/master<br />

interface IM 308C, or CP 5431 FMS/DP<br />

Communication between SIMATIC HMI Panels (DP slaves) and<br />

SIMATIC S5 (DP master) runs via PROFIBUS DP message<br />

frames in accordance with EN 50170 with higher-level<br />

"HMI profile". A function block which must be called for each<br />

connected SIMATIC HMI Panel is required in the PLC (FB is<br />

included in scope of delivery).


■ Overview (continued)<br />

Controller SIMATIC HMI<br />

Target hardware<br />

(PROTOCOL)<br />

(physics)<br />

SIMATIC S5 (AS511)<br />

S5-90U to 155U<br />

except CPU 922 < version 9,<br />

except CPU 928<br />

(6ES5 928-3UA11)<br />

except CPU 946/947<br />

(6ES5 94.-3UA11,<br />

6ES5 94.-3UA21,<br />

6ES5 94.-3UA22 < version 5)<br />

(TTY)<br />

S5-90U to 155U<br />

except CPU 922 < version 9,<br />

except CPU 928<br />

(6ES5 928-3UA11)<br />

except CPU 946/947<br />

(6ES5 94.-3UA11,<br />

6ES5 94.-3UA21,<br />

6ES5 94.-3UA22 < version 5)<br />

(TTY)<br />

System interface possible<br />

– System interface not possible<br />

OP 77A<br />

TP 177A<br />

Basic Panels<br />

1) <strong>PC</strong> cable with integrated level converter RS 232/TTY<br />

2) only OP 77B<br />

3) WinCC flexible 2008 Service Pack 2 and higher<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

OP 77B<br />

TP 177B DP<br />

OP 177B DP<br />

TP 177B DP/PN<br />

OP 177B DP/PN<br />

Mobile Panel 177 DP<br />

Mobile Panel 177 PN<br />

Operator panels<br />

System interfaces with WinCC flexible<br />

TP 277<br />

OP 277<br />

Mobile Panel 277<br />

Mobile Panel 277<br />

IWLAN<br />

MP 177<br />

MP 277<br />

MP 377<br />

WinCC flexible<br />

Runtime<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC S5<br />

Connection via<br />

– 2) – 6ES5 734-1BD20 1)<br />

(3.2 m)<br />

6XV1 440-2A…<br />

(see HMI accessories/connecting<br />

cables)<br />

– 3) 3) – 6AV6 671-8XJ00-<br />

0AX0<br />

(RS422-TTY adapter)<br />

6XV1 440-2A…<br />

(see HMI accessories/connecting<br />

cables)<br />

SIMATIC S5 (PROFIBUS DP + HMI)<br />

via PROFIBUS DP with – 3) 3) 4) PROFIBUS<br />

1 x S5-95U/L2-DP/master<br />

(6ES5 095-8ME02)<br />

4)<br />

(see <strong>Catalog</strong> IK PI)<br />

via PROFIBUS DP with – 3) 3) 4) PROFIBUS<br />

IM 308C on S5-115U,<br />

-135U, -155U<br />

except CPU 922 < version 9,<br />

except CPU 928<br />

(6ES5 928-3UA11),<br />

except CPU 946/947<br />

(6ES5 94.-3UA11,<br />

6ES5 94.-3UA21,<br />

6ES5 94.-3UA22 < version 5)<br />

4)<br />

(see <strong>Catalog</strong> IK PI)<br />

via PROFIBUS DP with –<br />

3) 3) 4)<br />

PROFIBUS<br />

CP 5431 FMS/DP on<br />

S5-115U, -135U, -155U<br />

except CPU 922 < version 9,<br />

except CPU 928<br />

(6ES5 928-3UA11),<br />

except CPU 946/947 (6ES5<br />

94.-3UA11, 6ES5 94.-3UA21,<br />

6ES5 94.-3UA22 < version 5)<br />

4)<br />

(see <strong>Catalog</strong> IK PI)<br />

2/183<br />

2


2<br />

Operator panels<br />

System interfaces with WinCC flexible<br />

SIMATIC 505<br />

■ Overview<br />

A variety of interfaces differing in respect of type and performance<br />

are available for linking SIMATIC HMI Panels to<br />

SIMATIC 505. However, a feature common to all is that from the<br />

point of view of the connected SIMATIC HMI Panel, the<br />

connection is always a logical point-to-point one, that is, there is<br />

always a fixed assignment between an HMI Panel and a PLC.<br />

NITP interface (not for OP 77A, TP 177A, Basic Panel,<br />

Mobile Panel 177 PN, Mobile Panel 277 IWLAN)<br />

The NITP interface runs via the PG interface of the SIMATIC 505<br />

and uses the associated CPU resources, that is, the performance<br />

capability of the SIMATIC HMI Panel is determined by the<br />

performance capability of the SIMATIC CPU used.<br />

Controller SIMATIC HMI<br />

Target hardware<br />

(PROTOCOL)<br />

(physics)<br />

SIMATIC 505 (NITP)<br />

PLC 525, 535, 565T<br />

(RS 232)<br />

PLC 545, 555<br />

(RS 232)<br />

PLC 535, 545/CPU 1101,<br />

565T (RS 422)<br />

System interface possible<br />

– System interface not possible<br />

1) Not Mobile Panel 177 PN, Mobile Panel 277 IWLAN;<br />

Mobile Panel 177 DP, Mobile Panel 277 connection via special<br />

connecting cable and terminal box (see Mobile Panel); see manual for<br />

cable assignment.<br />

2) The RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required for<br />

Touch Panels, Operator Panels, and Multi Panels<br />

3) A standard adapter (9-/25-pin male) is required on the PLC<br />

4) A commercially available level converter (RS 232/RS 422) is required<br />

on the <strong>PC</strong><br />

5) Connection via integrated MPI/PROFIBUS interface, use the<br />

CP 5611 A2 with a standard <strong>PC</strong><br />

6) Detailed information (cable assignment) can be found in the online<br />

help for WinCC flexible and in the Communication User Manual for<br />

Windows-based systems<br />

7) Bus connector 6GK1 500-0EA02<br />

2/184<br />

OP 77A<br />

TP 177A<br />

Basic Panels<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

OP 77B<br />

TP 177B DP<br />

OP 177B DP<br />

TP 177B DP/PN<br />

OP 177B DP/PN<br />

Mobile Panel 177 DP<br />

Mobile Panel 177 PN<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

PROFIBUS DP interface (not for OP 77A, TP 177A, Basic<br />

Panel, Mobile Panel 177 PN, Mobile Panel 277 IWLAN)<br />

SIMATIC 505 PLC or SIMATIC 545, SIMATIC 555 with CP 5434<br />

With the PROFIBUS DP interface, up to 30 SIMATIC HMI Panels<br />

can be connected as SLAVES to one SIMATIC 545, 555 via a<br />

PROFIBUS network, with plug-in PROFIBUS DP/master interface<br />

type CP 5434.<br />

Communication between SIMATIC HMI Panels (DP slaves) and<br />

SIMATIC 505 (DP master) runs via PROFIBUS DP message<br />

frames in accordance with EN 50170 with higher-level<br />

"HMI profile". An application ladder which must be called for<br />

each connected SIMATIC HMI Panel is required in the PLC<br />

(example of application ladder included in ProTool scope of<br />

delivery).<br />

TP 277<br />

OP 277<br />

Mobile Panel 277<br />

Mobile Panel 277 IWLAN<br />

MP 177<br />

MP 277<br />

MP 377<br />

WinCC flexible<br />

Runtime<br />

Connection via<br />

– • 1) 2) • 1) 2) • PPX: 2601 094-<strong>80</strong>01 3)<br />

See online help 6)<br />

– • 1) 2) • 1) 2) • PPX: 2601 094-<strong>80</strong>01 3)<br />

6XV1 440-2K…<br />

(see HMI accessories/<br />

connecting cables)<br />

– • 1) • 1) • 4) See online help 6)<br />

PLC 545/CPU 1102, 555<br />

(RS 422)<br />

– • 1) • 1) • 4) See online help 6)<br />

SIMATIC 505 (PROFIBUS DP + HMI)<br />

via PROFIBUS DP to<br />

– •<br />

1 x PLC 545, 555 with<br />

CP 5434<br />

1) • 1) • 5) PROFIBUS 7)<br />

(see <strong>Catalog</strong> IK PI)


■ Overview<br />

Allen Bradley<br />

Three communication protocols are available for the interface<br />

between SIMATIC TP/OP/MP and Allen Bradley:<br />

DF1 interface (not on OP 73, Basic Panel PN,<br />

Mobile Panel 177 PN, Mobile Panel 277 IWLAN)<br />

This communication between SIMATIC TP/OP/MP and Allen<br />

Bradley runs on the basis of the DF1 protocol; the following have<br />

been tested and released:<br />

Direct connection between a SIMATIC TP/OP/MP and the<br />

PG interface on an Allen Bradley PLC5 or the DF1 interface on<br />

an Allen Bradley SLC500 (point-to-point link)<br />

The integration of SIMATIC TP/OP/MP via Allen Bradley KF2<br />

gateway in an Allen Bradley DH+ network. Communication is<br />

possible between SIMATIC TP/OP/MP and up to 4 SLC<br />

500 PLCs or PLC5s (multipoint link from the point of view of<br />

the SIMATIC TP/OP/MP; only one connection possible with<br />

TP 170A)<br />

The integration of SIMATIC TP/OP/MP via Allen Bradley KF3<br />

gateway in an Allen Bradley DH485 network. Communication<br />

is possible between SIMATIC TP/OP/MP and up to 4 PLCs<br />

type SLC 500 or MicroLogix (multipoint link from the point of<br />

view of the SIMATIC TP/OP/MP; only one connection possible<br />

with TP 170A)<br />

DH485 interface (not on OP 73, OP 77A, TP 177A, Basic Panel,<br />

Mobile Panel 177 PN, Mobile Panel 277 IWLAN)<br />

This communication between SIMATIC TP/OP/MP and Allen<br />

Bradley runs on the basis of the DH485 protocol; the following<br />

have been tested and released:<br />

Direct connection between a SIMATIC TP/OP/MP and an Allen<br />

Bradley SLC500 or MicroLogix (point-to-point link)<br />

The integration of SIMATIC TP/OP/MP via Allen Bradley<br />

AIC adapter in an Allen Bradley DH485 network.<br />

Communication is possible between SIMATIC TP/OP/MP and<br />

up to 4 PLCs type SLC 500 or MicroLogix (multipoint link from<br />

the point of view of the SIMATIC TP/OP/MP; only one<br />

connection possible with TP 170A)<br />

The integration of SIMATIC TP/OP/MP (not <strong>PC</strong> with<br />

WinCC flexible Runtime) in an Allen Bradley DH485 network.<br />

Communication is possible between SIMATIC TP/OP/MP and<br />

up to 4 PLCs type SLC 500 or MicroLogix (multipoint link from<br />

the point of view of the SIMATIC TP/OP/MP; only one<br />

connection possible with TP 170A)<br />

Ethernet IP protocol (not on OP 73, OP 77A, TP 177A,<br />

Basic Panel, OP 77B, TP 177B DP, OP 177B DP,<br />

Mobile Panel 177 DP, Mobile Panel 277 IWLAN)<br />

This communication between SIMATIC TP/OP/MP and Allen<br />

Bradley runs based on the Ethernet IP protocol;<br />

SIMATIC TP/OP/MP integration is tested and released in an<br />

Ethernet IP network. Communication is possible between<br />

SIMATIC TP/OP/MP and up to 4 ControlLogix or CompactLogix<br />

PLCs (multipoint link from the point of view of the<br />

SIMATIC TP/OP/MP)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

System interfaces with WinCC flexible<br />

Third-party controllers<br />

GE-Fanuc (not on OP 73, OP 77A, TP 177A, Basic Panel,<br />

Mobile Panel 177 PN, Mobile Panel 277 IWLAN)<br />

Communication between SIMATIC TP/OP/MP and GE-Fanuc<br />

runs on the basis of the SNP protocol; the following have been<br />

tested and released:<br />

Direct connection between a SIMATIC TP/OP/MP and a<br />

GEF 90-Micro, 90-30 or 90-70 (point-to-point link)<br />

Integration of SIMATIC TP/OP/MP in an RS 422 network<br />

via adapter. Communication is possible between<br />

SIMATIC TP/OP/MP and up to 4 GEF 90-Micro, 90-30 or<br />

90-70 PLCs (multipoint link from the point of view of the<br />

SIMATIC TP/OP/MP; only one connection possible with<br />

TP 170A)<br />

The integration of SIMATIC TP/OP/MP (not <strong>PC</strong> with ProTool/Pro<br />

Runtime or WinCC flexible Runtime) in an RS 422 network.<br />

Communication is possible between SIMATIC TP/OP/MP and<br />

up to 4 GEF 90-Micro, 90-30 or 90-70 PLCs (multipoint link<br />

from the point of view of the SIMATIC TP/OP/MP; only one<br />

connection possible with TP 170A)<br />

LG GLOFA GM (not on OP 73, OP 77A, TP 177A, Basic Panel,<br />

Mobile Panel 177 PN, Mobile Panel 277 IWLAN)<br />

Communication between SIMATIC TP/OP/MP and<br />

LG GLOFA GM runs on the basis of the dedicated protocol;<br />

the following have been tested and released:<br />

Connection between a SIMATIC TP/OP/MP and a<br />

LG GLOFA GM with Cnet module (point-to-point link)<br />

Integration of SIMATIC TP/OP/MP in an RS 422 network via<br />

LG Cnet module. Communication is possible between<br />

SIMATIC TP/OP/MP (not <strong>PC</strong> with ProTool/Pro Runtime) and up<br />

to 4 LG GLOFA GM PLCs on the network (multipoint link from<br />

the point of view of the SIMATIC TP/OP/MP; only one<br />

connection possible with TP 170A)<br />

Mitsubishi (not with OP 73, Basic Panel,<br />

Mobile Panel 177 PN, Mobile Panel 277 IWLAN)<br />

Two communication protocols are available for the interface<br />

between SIMATIC TP/OP/MP and Mitsubishi:<br />

FX protocol<br />

This communication between SIMATIC TP/OP/MP and<br />

Mitsubishi runs on the basis of the FX protocol; the direct<br />

connection between a SIMATIC TP/OP/MP and the PG interface<br />

of a Mitsubishi FX/FX0 (logical point-to-point link) has been<br />

tested and released.<br />

MP4 protocol<br />

This communication between SIMATIC TP/OP/MP and<br />

Mitsubishi runs on the basis of the MP4 protocol; the following<br />

have been tested and released:<br />

Direct connection between a SIMATIC TP/OP/MP and a<br />

Mitsubishi Series FX, Series A or Series Q (point-to-point link)<br />

Integration of SIMATIC TP/OP/MP in an RS 422 network via<br />

Mitsubishi converter FX-48SC-IF. Communication is possible<br />

between SIMATIC TP/OP/MP and up to 4 Series FX, Series A<br />

or Series Q PLCs (multipoint link from the point of view of the<br />

SIMATIC TP/OP/MP; only one connection possible with<br />

TP 170A)<br />

The integration of SIMATIC TP/OP/MP (not <strong>PC</strong> with ProTool/<br />

Pro Runtime or WinCC flexible Runtime) in an RS 422 network.<br />

Communication is possible between SIMATIC TP/OP/MP and<br />

up to 4 Series FX, Series A or Series Q PLCs (multipoint link<br />

from the point of view of the SIMATIC TP/OP/MP; only one<br />

connection possible with TP 170A)<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/185<br />

2


2<br />

Operator panels<br />

System interfaces with WinCC flexible<br />

Third-party controllers<br />

■ Overview (continued)<br />

Modicon<br />

Two communication protocols are available for the interface<br />

between SIMATIC TP/OP/MP and Modicon:<br />

Modbus protocol (not with OP 73, Basic Panel PN,<br />

Mobile Panel 177 PN, Mobile Panel 277 IWLAN)<br />

Communication between SIMATIC TP/OP/MP and Modicon runs<br />

on the basis of the Modbus protocol; the following have been<br />

tested and released:<br />

Direct connection between a SIMATIC TP/OP/MP and the<br />

Modbus interface on a Modicon 984, TSX Quantum or<br />

TSX Compact (point-to-point link)<br />

The integration of a SIMATIC TP/OP/MP via Modicon Modbus<br />

PLUS bridge BM85-000/the bridge function on a<br />

MODICON 984-145/TSX Quantum in a Modbus PLUS network<br />

and communication between SIMATIC TP/OP/MP<br />

(Modbus/master) and up to 4 Modicon 984 or TSX Quantum<br />

PLCs (Modbus/slave) on the network (multipoint link from the<br />

point of view of the SIMATIC TP/OP/MP; only one connection<br />

possible with TP 170A).<br />

Modbus TCP/IP protocol (not on OP 73, OP 77A, TP 177A,<br />

Basic Panel DP, OP77B, TP 177B DP, OP 177B DP,<br />

Mobile Panel 177 DP, Mobile Panel 277 IWLAN)<br />

Communication between SIMATIC TP/OP/MP and Modicon runs<br />

on the basis of the Modbus TCP/IP protocol; the following have<br />

been tested and released:<br />

Integration of SIMATIC TP/OP/MP in a Modbus<br />

TCP/IP network. Communication is possible between<br />

SIMATIC TP/OP/MP and up to 4 Momentum, TSX Micro<br />

(TSX 37), TSX Premium (TSX 57), TSX Unity Premium,<br />

TSX Quantum or TSX Unity Quantum PLCs (multipoint link<br />

from the point of view of the SIMATIC TP/OP/MP)<br />

The communication between SIMATIC TP/OP/MP via<br />

TCP/IP Modbus Plus Bridge 174 CEV 200 40/Modbus PLUS<br />

network and Modicon 984 (except 984A, 984B, 984X),<br />

TSX Compact, TSX Quantum or TSX Unity Quantum<br />

(multipoint link from the point of view of the<br />

SIMATIC TP/OP/MP)<br />

2/186<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Omron (not with OP 73, Basic Panel PN,<br />

Mobile Panel 177 PN, Mobile Panel 277 IWLAN)<br />

Communication between SIMATIC TP/OP/MP and Omron runs<br />

on the basis of the Link/MultiLink protocol; the following have<br />

been tested and released:<br />

Direct connection between a SIMATIC TP/OP/MP and an<br />

Omron Sysmac C, Sysmac α or Sysmac CV (point-to-point<br />

link)<br />

Integration of SIMATIC TP/OP/MP in an RS 422 network via<br />

Omron converter NT-AL001. Communication is possible<br />

between SIMATIC TP/OP/MP and up to 4 Sysmac C, Sysmac<br />

α or Sysmac CV PLCs (multipoint link from the point of view of<br />

the SIMATIC TP/OP/MP; only one connection possible with<br />

TP 170A)<br />

The integration of SIMATIC TP/OP/MP (not <strong>PC</strong> with ProTool/<br />

Pro Runtime or WinCC flexible Runtime) in an RS 422 network.<br />

Communication is possible between SIMATIC TP/OP/MP and<br />

up to 4 Sysmac C, Sysmac α or Sysmac CV PLCs (multipoint<br />

link from the point of view of the SIMATIC TP/OP/MP; only one<br />

connection possible with TP 170A)<br />

Telemecanique (not on OP 73, OP 77A, TP 177A, Basic Panel,<br />

Mobile Panel 177 PN, Mobile Panel 277 IWLAN,<br />

WinCC flexible Runtime)<br />

Data exchange between SIMATIC TP/OP/MP and Telemecanique<br />

runs on the basis of the UNI-TELWAY protocol; the<br />

following have been tested and released:<br />

Connection between a SIMATIC TP/OP/MP (UNI-T/slave) via<br />

Telemecanique outlet TSX SCA62 and a Telemecanique<br />

TSX 17 or TSX 47/67/87/107 (UNI-T/master) (logical point-topoint<br />

link)<br />

Connection between a SIMATIC TP/OP/MP (UNI-T/slave) via<br />

Telemecanique outlets TSX SCA62 + ACC01 and a<br />

Telemecanique TSX 37 or TSX 57 (UNI-T/master) (logical<br />

point-to-point link)<br />

The integration of a SIMATIC TP/OP/MP via Telemecanique<br />

outlet TSX SCA62 in a UNI-TELWAY network and<br />

communication between SIMATIC TP/OP/MP (UNI-T/slave)<br />

and up to 4 TSX 17, TSX 37, TSX 57 or<br />

TSX 47/67/87/107 PLCs (UNI-T/master or slave) on the<br />

network (multipoint link from the point of view of the<br />

SIMATIC TP/OP/MP; only one connection possible with<br />

TP 170A).


■ Overview (continued)<br />

Controller SIMATIC HMI<br />

Target hardware<br />

(PROTOCOL)<br />

(physics)<br />

Allen Bradley (DF1)<br />

SLC 500/03,04,05 or<br />

MicroLogix (RS 232)<br />

PLC 5/11,20,30,40,60,<strong>80</strong><br />

(RS 232)<br />

PLC 5/11,20,30,40,60,<strong>80</strong><br />

(RS 422)<br />

via KF2 gateway and<br />

DH+ network with up to<br />

4xSLC 50/04 or<br />

PLC 5/11,20,30,40,60,<strong>80</strong><br />

(RS 232)<br />

via KF2 gateway and<br />

DH+ network with up to<br />

4xSLC 50/04 or<br />

PLC 5/11,20,30,40,60,<strong>80</strong><br />

(RS 422)<br />

via KF3 gateway and<br />

DH485 network with up to<br />

4xSLC 500/00,01,02,03,04,<br />

05 or MicroLogix (RS 232)<br />

Allen Bradley (DH485)<br />

SLC 500/03,04,05 or<br />

MicroLogix (RS 232)<br />

via AIC adapter and<br />

DH485 network with up to<br />

4xSLC 500 or MicroLogix<br />

(RS 232)<br />

via DH485 network with up to<br />

4x<br />

SLC 500/00,01,02,03,04,05 or<br />

MicroLogix (RS 485)<br />

Allen Bradley (Ethernet IP)<br />

via Ethernet IPnetwork with up<br />

to 4 x ControlLogix<br />

(1756-L61, 1756-L62,<br />

1756-L63, 1756-L64,<br />

1756-L65, each with Ethernet<br />

module 1756-ENBT)<br />

GuardLogix (1756-L61S,<br />

1756-L62S, 1756-L61S, each<br />

with Ethernet module<br />

1756-ENBT) or<br />

CompactLogix (1769-L32E,<br />

1769-L35E, each with Ethernet<br />

interface onboard)<br />

System interface possible<br />

– System interface not possible<br />

OP 77A<br />

TP 177A<br />

Basic<br />

Panels<br />

1) Not Basic Panel PN, Mobile Panel 177 PN, Mobile Panel 277 IWLAN;<br />

Mobile Panel 177 DP, Mobile Panel 277 connection via special<br />

connecting cable and terminal box (see Mobile Panel); see manual for<br />

cable assignment<br />

2) The RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required for<br />

Basic Panel, Touch Panel, Operator Panel, and Multi Panel<br />

3) Only TP 177B DP/PN, OP 177B DP/PN, Mobile Panel 177 PN<br />

4) Mobile Panel 177 PN, Mobile Panel 277 connection via special<br />

connecting cable and terminal box (see Mobile Panel); see manual for<br />

cable assignment<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

OP 77B<br />

TP 177B DP<br />

OP 177B DP<br />

TP 177B DP/PN<br />

OP 177B DP/PN<br />

Mobile Panel 177 DP /<br />

177 PN<br />

Operator panels<br />

System interfaces with WinCC flexible<br />

TP 277<br />

OP 277<br />

Mobile Panel 277 /<br />

277 IWLAN<br />

MP 177<br />

MP 277<br />

MP 377<br />

Third-party controllers<br />

WinCC<br />

flexible<br />

Runtime<br />

5) Not Mobile Panel 277 IWLAN (wireless interface, see Mobile Panel)<br />

6) Connection via integrated Industrial Ethernet interface; use the<br />

CP 1612 with a standard <strong>PC</strong><br />

7) Allen Bradley <strong>PC</strong> cable<br />

8) Cable for connection to KF2/KF3 gateway; a gander changer<br />

(25-pin socket/25-pin socket) is required on the gateway side<br />

9) Detailed information (cables used) see FAQ:<br />

http://support.automation.siemens.com/WW/view/en/29034071<br />

in the online help for WinCC flexible and in the Communication User<br />

Manual for Windows-based systems<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Connection via<br />

1) 2) 1) 2) 1) 2) 1) 2) 1747 CP3 7)<br />

see FAQ 9)<br />

1) 2) 1) 2) 1) 2) 1) 2) 1784 CP10 7)<br />

see FAQ 9)<br />

1) 1) 1) 1) – see FAQ 9)<br />

1) 2) 1) 2) 1) 2) 1) 2) 1784 CP10 7) 8)<br />

see FAQ 9)<br />

1) 1) 1) 1) – see FAQ 9)<br />

1) 2) 1) 2) 1) 2) 1) 2) 1784 CP10 7) 8)<br />

see FAQ 9)<br />

– – 1) 2) 1) 2) see FAQ 9)<br />

– – 1) 2) 1) 2) see FAQ 9)<br />

– – 1) 1) – see FAQ 9)<br />

– – 3) 4) 4) see FAQ 9)<br />

2/187<br />

2


2<br />

Operator panels<br />

System interfaces with WinCC flexible<br />

Third-party controllers<br />

■ Overview (continued)<br />

Controller SIMATIC HMI<br />

Target hardware (PROTOCOL)<br />

(physics)<br />

GE-Fanuc (SNP)<br />

GEF 90-Micro, 90-30, 90-70<br />

(RS 232)<br />

via adapter with up to 4 x<br />

GEF 90-Micro, 90-30, 90-70<br />

(RS 232)<br />

via adapter with up to<br />

4xGEF 90-Micro, 90-30, 90-70<br />

(RS 422)<br />

LG GLOFA (Dedicated)<br />

GLOFA-GM with Cnet module<br />

(RS 232)<br />

With up to 4 x GLOFA-GM with<br />

Cnet module (RS 422)<br />

System interface possible<br />

– System interface not possible<br />

1) Not Mobile Panel 177 PN, Mobile Panel 277 IWLAN;<br />

Mobile Panel 177 DP, Mobile Panel 277 connection via special<br />

connecting cable and terminal box (see Mobile Panel); see manual for<br />

cable assignment<br />

2) The RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required for<br />

Touch Panels, Operator Panels, and Multi Panels<br />

3) With connection using a Mitsubishi <strong>PC</strong> cable, an 15-pin/9-pin adapter<br />

6XV1 440-2UE32 is required<br />

2/188<br />

OP 77A<br />

TP 177A<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Basic<br />

Panels<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

OP 77B<br />

TP 177B DP<br />

OP 177B DP<br />

TP 177B DP/PN<br />

OP 177B DP/PN<br />

Mobile Panel<br />

177 DP<br />

Mobile Panel<br />

177 PN<br />

TP 277<br />

OP 277<br />

Mobile Panel 277<br />

Mobile Panel 277<br />

IWLAN<br />

MP 177<br />

MP 277<br />

MP 377<br />

WinCC flexible<br />

Runtime<br />

Connection via<br />

– – • 1) 2) • 1) 2) see FAQ 4)<br />

– – • 1) 2) 1) 2) • see FAQ 4)<br />

– – • 1) 1) – see FAQ 4)<br />

– – • 1) 2) 1) 2) • see FAQ 4)<br />

– – • 1) 1) – see FAQ 4)<br />

Mitsubishi FX<br />

FX0 (RS 422) – – – – • SC-09 6)<br />

– – • 1) 1) – see FAQ 4)<br />

FX0n, FX1n, FX2n (RS 422) – – – – • SC-09 6)<br />

– – • 1) 1) – see FAQ 4)<br />

FX1N-14MR-DS • 1) 6) • 1) 6) – – – SC-09 6)<br />

FX1S-10MR-DS<br />

FX2N-16MR-DS (RS 422)<br />

Mitsubishi (MP4)<br />

Series FX with communication<br />

module<br />

– – • 1) 2) • 1) 2) • see FAQ 4)<br />

Series A (AnN, AnA, AnU, AnS)<br />

with interface module<br />

Series Q (QnA, QnAS) with<br />

interface module (RS 232)<br />

via FX-48SC-IF converter with<br />

up to 4 PLCs<br />

– – • 1) 2) 1) 2) • see FAQ 4)<br />

Series FX with communication<br />

module<br />

Series A (AnN, AnA, AnU, AnS)<br />

with interface module<br />

Series Q (QnA, QnAS) with<br />

interface module<br />

(RS 232)<br />

with up to 4 PLCs – – • 1) 1) – see FAQ 4)<br />

Series FX with communication<br />

module<br />

Series A (AnN, AnA, AnU, AnS)<br />

with interface module<br />

Series Q (QnA, QnAS) with<br />

interface module (RS 422)<br />

4) Detailed information (cables used) see FAQ:<br />

http://support.automation.siemens.com/WW/view/en/29034071 in the<br />

online help for WinCC flexible and in the Communication User Manual<br />

for Windows-based systems<br />

5) Mitsubishi <strong>PC</strong> cable with integrated level converter RS 232/RS422<br />

6) WinCC flexible 2008 ServicePack 2 and higher


■ Overview (continued)<br />

Controller SIMATIC HMI<br />

Target hardware (PROTOCOL)<br />

(physics)<br />

Modicon (Modbus)<br />

984-120, 130, 131, 141, 145, 3<strong>80</strong>, 381,<br />

185, 4<strong>80</strong>, 485, 6<strong>80</strong>, 685, 7<strong>80</strong>, 785, or<br />

TSX-Quantum-CPU 113, 213, 424, 434,<br />

534 (RS 232)<br />

via bridge BM85-000 or PLC with<br />

bridge function. /<br />

Modbus PLUS – network with up to<br />

4 x 984-120, ... or<br />

TSX Quantum - CPU 113, or<br />

TSX Contact (RS 232)<br />

System interface possible<br />

– System interface not possible<br />

OP 77A<br />

TP 177A<br />

Basic<br />

Panels<br />

1) Not Mobile Panel 177 PN, Mobile Panel 277 IWLAN;<br />

Mobile Panel 177 DP, Mobile Panel 277 connection via special<br />

connecting cable and terminal box (see Mobile Panel); see manual for<br />

cable assignment<br />

2) The RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required for<br />

Touch Panels, Operator Panels, and Multi Panels<br />

3) Only TP 177B DP/PN, OP 177B DP/PN, Mobile Panel 177 PN<br />

4) Mobile Panel 177 PN, Mobile Panel 277 connection via special<br />

connecting cable and terminal box (see Mobile Panel); see manual for<br />

cable assignment<br />

OP 77B<br />

TP 177B DP<br />

OP 177B DP<br />

TP 177B DP/PN<br />

OP 177B DP/PN<br />

Mobile Panel 177 DP<br />

Mobile Panel 177 PN<br />

Operator panels<br />

System interfaces with WinCC flexible<br />

TP 277<br />

OP 277<br />

Mobile Panel 277<br />

Mobile Panel 277<br />

IWLAN<br />

MP 177<br />

MP 277<br />

MP 377<br />

Third-party controllers<br />

WinCC<br />

flexible<br />

Runtime<br />

5) Not Mobile Panel 277 IWLAN (wireless interface, see Mobile Panel)<br />

6) Connection via integrated Industrial Ethernet interface; use the<br />

CP 1612 with a standard <strong>PC</strong><br />

7) Detailed information (cables used) see FAQ:<br />

http://support.automation.siemens.com/WW/view/en/29034071 in the<br />

online help for WinCC flexible and in the Communication User Manual<br />

for Windows-based systems<br />

8) WinCC flexible 2008 ServicePack 2 and higher<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Connection via<br />

1) 2) 1) 2) 1) 2) 1) 2) See FAQ 7)<br />

1) 2) 1) 2) 1) 2) 1) 2) See FAQ 7)<br />

TSX Compact (RS 232) 1) 2) 1) 2) 1) 2) 1) 2) See FAQ 7)<br />

Modicon (Modbus TCP/IP)<br />

via Modbus TCP/IP – network<br />

with up to 4 x TSX Unity Quantum or<br />

TSX Unity Premium or<br />

TSX Quantum or TSX Quantum with<br />

TCP/IP module 140 NOE 771 01 or<br />

TSX Unity Premium or TSX Premium<br />

with TCP/IP module TSX ETY 110 or<br />

TSX Micro with<br />

TCP/IP module TSX ETY 410 or<br />

Momentum with<br />

CPU adapter 171 CCC 9<strong>80</strong> 30<br />

via TCP/IP modbusplus bridge<br />

174 CEV 200 40 / Modbus PLUS –<br />

network with up to 4 x TSX Unity<br />

Quantum or TSX Quantum or<br />

TSX Compact or 984-120, ... (except<br />

984A, 984B, 984X )<br />

via Modbus TCP/IP – network<br />

with up to 4 x TSX Unity Quantum or<br />

TSX Unity Premium or<br />

TSX Quantum or TSX Quantum with<br />

TCP/IP module 140NOE 771 01 or<br />

TSX Unity Premium or TSX Premium<br />

with TCP/IP module TSX ETY 110 or<br />

TSX Micro with<br />

TCP/IP module TSX ETY 410 or<br />

Momentum with<br />

CPU adapter 171 CCC 9<strong>80</strong> 30<br />

via TCP/IP modbusplus bridge<br />

174 CEV 200 40 /<br />

Modbus PLUS – network with up to<br />

4 x TSX Unity Quantum or TSX<br />

Quantum or TSX Compact<br />

– –<br />

– –<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

3) 4) 4) 5)<br />

3) 4) 4) 5)<br />

3) 8) 3) 8) – – –<br />

3) 8) 3) 8) – – –<br />

2/189<br />

2


2<br />

Operator panels<br />

System interfaces with WinCC flexible<br />

Third-party controllers<br />

■ Overview (continued)<br />

Controller SIMATIC HMI<br />

Target hardware (PROTOCOL)<br />

(physics)<br />

Omron (Link/MultiLink)<br />

SYSMAC C<br />

(except CPU CQM1 – CPU 11/21)<br />

SYSMAC Alpha<br />

SYSMAC CV (RS 232)<br />

via NT-AL001 converter with up to<br />

4 PLCs<br />

SYSMAC C<br />

(except CPU CQM1 – CPU 11/21)<br />

SYSMAC Alpha<br />

SYSMAC CV (RS 232)<br />

System interface possible<br />

– System interface not possible<br />

1) Not Mobile Panel 177 PN, Mobile Panel 277 IWLAN;<br />

Mobile Panel 177 DP, Mobile Panel 277 connection via special<br />

connecting cable and terminal box (see Mobile Panel); see manual for<br />

cable assignment.<br />

2) The RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required for<br />

Touch Panels, Operator Panels, and Multi Panels<br />

3) Detailed information (cables used) see FAQ:<br />

http://support.automation.siemens.com/WW/view/en/29034071 in the<br />

online help for WinCC flexible and in the Communication User Manual<br />

for Windows-based systems<br />

4) WinCC flexible 2008 ServicePack 2 and higher<br />

2/190<br />

OP 77A<br />

TP 177A<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Basic<br />

Panels<br />

OP 77B<br />

TP 177B DP<br />

OP 177B DP<br />

TP 177B DP/PN<br />

OP 177B DP/PN<br />

Mobile Panel 177 DP<br />

Mobile Panel 177 PN<br />

TP 277<br />

OP 277<br />

Mobile Panel 277<br />

Mobile Panel 277<br />

IWLAN<br />

MP 177<br />

MP 277<br />

MP 377<br />

WinCC<br />

flexible<br />

Runtime<br />

Connection via<br />

– – • 1) 2) • 1) 2) • see FAQ 3)<br />

– – 1) 2) 1) 2) see FAQ 3)<br />

with up to 4 PLCs<br />

SYSMAC C<br />

(except CPU CQM1 – CPU 11/21)<br />

SYSMAC Alpha<br />

SYSMAC CV (RS 422)<br />

– – 1) 1) – see FAQ 3)<br />

CP1L-L14DT1-D • 1) 4) • 1) 4) C1H-Y20DT-D<br />

CJ1M CPU11<br />

Telemecanique (UNI-TELWAY)<br />

– – –<br />

via TSX SCA62 outlet with TSX 17<br />

or TSX 47/67/87/107 (RS 485)<br />

– – • 1) • 1) – see FAQ 3)<br />

via TSX SCA62 + ACC01 outlets<br />

with TSX 37/57 (RS 485)<br />

via TSX SCA62 outlet and<br />

UNI-TELWAY network with4 x<br />

TSX 17 or TSX 37/57 (+ACC 01) or<br />

TSX 47/67/87/107 (RS 485)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

– – • 1) • 1) – see FAQ 3)<br />

– – • 1) • 1) – see FAQ 3)


■ Overview<br />

The SIMATIC Touch Panel (TP), Operator Panel (OP), Basic<br />

Panel, Comfort Panel, Mobile Panel, multifunctional platforms<br />

(MP) 1) offer HMI functionality for the control systems:<br />

SIMATIC S7<br />

SINUMERIK 2)<br />

Non-<strong>Siemens</strong> controllers:<br />

- Allen Bradley<br />

-Mitsubishi<br />

- Modicon<br />

-Omron<br />

For more detailed information, refer to the WinCC flexible user<br />

manual, the "Windows-based systems communication" manual,<br />

and the WinCC flexible online help.<br />

1) For the sake of simplicity, SIMATIC Panel is always used in the text<br />

below. This is not restrictive, as the information is valid for all systems<br />

referred to above. If there are constraints, direct reference is made to<br />

them in the text.<br />

2) Required under WinCC flexible: "SINUMERIK HMI copy license<br />

WinCC flexible CE" and "SINUMERIK HMI copy license OA".<br />

For configuring, a "SINUMERIK HMI engineering package<br />

WinCC flexible" is also necessary.<br />

Note:<br />

Interface options for HMI devices: See the individual device<br />

descriptions.<br />

System interface possible<br />

– System interface not possible<br />

1) Only through DCOM/XML gateway in scope of delivery of<br />

WinCC Advanced for access to O<strong>PC</strong> XML server of the SIMATIC Panel<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

System interfaces with WinCC (TIA Portal)<br />

System interfaces with WinCC (TIA Portal)<br />

O<strong>PC</strong> communication and HTTP communication are offered for all<br />

Panels with an integrated Ethernet interface. Both O<strong>PC</strong> and<br />

HTTP communication can be used in parallel with the process<br />

links to SIMATIC S7 or non-<strong>Siemens</strong> PLCs.<br />

O<strong>PC</strong> communication<br />

O<strong>PC</strong> Data Access is an open standard for exchanging both local<br />

and remote variables between various applications via Industrial<br />

Ethernet. The original version of O<strong>PC</strong> is based on Microsoft<br />

COM/DCOM and, therefore, requires a Microsoft Windowsbased<br />

<strong>PC</strong> operating system (not Windows CE) on both clients<br />

and servers. As O<strong>PC</strong> XML, communication is based on the<br />

Internet standard SOAP/XML and is, therefore, suitable for<br />

embedded systems with Windows CE.<br />

HTTP communication for variable exchange between<br />

SIMATIC HMI systems<br />

Communication based on HTTP message frames enables<br />

variables to be exchanged between SIMATIC HMI systems.<br />

Communication standard SIMATIC HMI<br />

Version Comfort Panel TP 177B DP/PN TP 277<br />

MP 277<br />

WinCC Advanced<br />

OP 177B DP/PN OP 277<br />

MP 377<br />

Runtime<br />

Mobile Panel 177 PN Mobile Panel 277<br />

WinCC Professional<br />

MP 177<br />

Runtime<br />

O<strong>PC</strong> Data Access V2.05a + O<strong>PC</strong> Data Access XML V1.00<br />

O<strong>PC</strong> DA Client<br />

(COM/DCOM)<br />

– – – –<br />

O<strong>PC</strong> DA server<br />

(COM/DCOM)<br />

– – – –<br />

O<strong>PC</strong> XML DA client<br />

(SOAP/XML)<br />

– – – – 1)<br />

O<strong>PC</strong> XML DA server<br />

(SOAP/XML)<br />

– – –<br />

HTTP communication for variable exchange between SIMATIC HMI systems<br />

HTTP client<br />

HTTP server<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/191<br />

2


2<br />

Operator panels<br />

System interfaces with WinCC (TIA Portal)<br />

SIMATIC S7<br />

■ Overview<br />

The following types of interface are differentiated in respect of<br />

the link between the SIMATIC Panels and SIMATIC S7<br />

controllers:<br />

PROFINET interface:<br />

Coupling of SIMATIC Panel to SIMATIC S7 controllers via<br />

Industrial Ethernet TCP/IP using the integrated PROFINET<br />

interface of the CPU or, alternatively, a PROFINET interface<br />

module.<br />

MPI/PROFIBUS interface:<br />

Coupling of SIMATIC Panel to SIMATIC S7 controllers via<br />

MPI/PROFIBUS using the integrated MPI/PROFIBUS interface<br />

of the CPU for S7-300, S7-400 or the integrated PPI interface<br />

of the CPU in the case of S7-200 or, alternatively, a PROFIBUS<br />

interface module in the case of S7-1200, S7-300 and S7-400.<br />

PPI interface:<br />

Coupling of SIMATIC Panel to SIMATIC S7-200 via PPI network<br />

using the integrated PPI interface of the CPU<br />

The maximum possible number of S7 connections of one CPU is<br />

determined by its performance capacity (see <strong>Catalog</strong> <strong>ST</strong> 70);<br />

from the point of view of SIMATIC Panel, the following restrictions<br />

apply:<br />

OP 73: max. 2 connections<br />

OP 77A, TP 177A, Basic Panel, OP 77B, TP177B, OP 177B,<br />

Mobile Panel 177: max. 4 connections<br />

Comfort Panel, TP 277, OP 277; Mobile Panel 277, MP 177,<br />

MP 277, MP 377: max. 6 connections<br />

<strong>PC</strong> with <strong>PC</strong> WinCC Runtime Advanced: max. 8 connections<br />

PPI interface<br />

The PPI interface is a point-to-point connection between a<br />

SIMATIC Panel (PPI master) or alternatively a PG (PPI master)<br />

and an S7-200 (PPI slave).<br />

2/192<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

MPI/PROFIBUS interface or PROFINET interface<br />

The corresponding multipoint-enabled communication interfaces<br />

of SIMATIC Panels and SIMATIC S7 are used.<br />

The following are possible:<br />

Interface between one or a number of SIMATIC Panels<br />

(MPI master) and one or a number of S7-1200/300/400s or<br />

WinAC (MPI master) (possible network topology:<br />

MPI/PROFIBUS or Industrial Ethernet, TCP/IP)<br />

Interface between one or a number of SIMATIC Panels<br />

(MPI master) and one or a number of S7-200s (MPI slave) 1)<br />

(possible network topology: PPI, MPI/PROFIBUS)<br />

Unlike PPI connections, MPI connections are static connections<br />

that are set up during booting and then monitored.<br />

The original format of a master/master link has been joined by a<br />

master/slave link, which has enabled integration of the S7-200<br />

(except CPU 212). 1)<br />

In principle, this type of information exchange between<br />

SIMATIC Panels and SIMATIC S7 is independent of the network<br />

used, PPI, MPI/PROFIBUS or Industrial Ethernet:<br />

SIMATIC Panels are S7 clients and SIMATIC S7 CPUs are<br />

S7 servers.<br />

1) Constraints with regard to baud rate for S7-200; see <strong>Catalog</strong> <strong>ST</strong> 70.


■ Overview (continued)<br />

Controller SIMATIC HMI<br />

Target hardware<br />

(PROTOCOL)<br />

(physics)<br />

SIMATIC S7-1200 2)<br />

Via Ethernet (TCP/IP)<br />

to max. 4 x S7-1200<br />

Via MPI or PROFIBUS<br />

network to max.<br />

4 x S7-1200 with<br />

PROFIBUS module<br />

(DP-Master)<br />

CM 1243-5<br />

System interface possible<br />

– System interface not possible<br />

Note:<br />

OP 73<br />

OP 77A<br />

TP 177A<br />

SIMATIC S7-300, -400, Win AC 2)<br />

Via Ethernet (TCP/IP)<br />

to max. 4 x S7-300, -400,<br />

WinAC<br />

over MPI or PROFIBUS<br />

network to up to 4 x<br />

S7-300, S7-400, WinAC<br />

SIMATIC S7-200 2)<br />

Via Ethernet (TCP/IP)<br />

(MPI protocol)<br />

to max. 4 x S7-200<br />

over MPI or PROFIBUS<br />

network (MPI protocol)<br />

to up to 4 x S7-200<br />

over PPI network<br />

(MPI protocol)<br />

to up to 4 x S7-200<br />

over PPI network<br />

(PPI protocol)<br />

to max. 1 x S7-200<br />

– 5) 5)<br />

– 5) 5)<br />

– 5) 5)<br />

Detailed information regarding cable layout can be found in the<br />

online help for WinCC.<br />

1) Mobile Panel connection via special connecting cable and terminal<br />

box (see Mobile Panel), see Manual for cable layout.<br />

2) Controllers can be combined as desired<br />

3) OP 73 can only be interfaced with max. 2 x SIMATIC S7 (MPI); network<br />

operation (parallel PG, etc.) possible<br />

4) Max. transfer rate: 1.5 Mbit/s<br />

5) Only Basic Panel PN, TP 177B DP/PN, OP 177B DP/PN,<br />

Mobile Panel 177 PN<br />

6) Not Basic Panel PN, Mobile Panel 177 PN<br />

7) Connection via integrated MPI/PROFIBUS interface;<br />

use the CP 5611 A2 with a standard <strong>PC</strong><br />

8) Only on passive S7-200; OP 77B also on active S7-200<br />

9) Only OP 77B<br />

10) Can be interfaced via PPI to max. 1 x S7-200 (PPI); network operation<br />

(parallel PG, etc) is possible<br />

Basic Panel Comfort Panel OP 77B<br />

TP 177B DP<br />

OP 177B DP<br />

TP 177B DP/PN<br />

OP 177B DP/PN<br />

Mobile Panel 177 DP 1)<br />

Mobile Panel 177 PN 1)<br />

Operator panels<br />

System interfaces with WinCC (TIA Portal)<br />

TP 277<br />

OP 277<br />

Mobile Panel 277 1)<br />

MP 177<br />

MP 277<br />

MP 377<br />

3) 4) 6) 5) 7)<br />

3) 4) 6) 6) 7)<br />

3) 4) 6) 8) 6) 8) 8) 7) 8)<br />

3) 4) 6) – 9) – –<br />

– –<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

10) 10) 10) 7)10)<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC S7<br />

WinCC Runtime<br />

Advanced<br />

2/193<br />

2


2<br />

Operator panels<br />

System interfaces with WinCC (TIA Portal)<br />

Third-party controllers<br />

■ Overview<br />

The SIMATIC Touch Panel (TP), Operator Panel (OP),<br />

Basic Panel, Comfort Panel, Mobile Panel, multifunctional<br />

platforms (MP) and the SIMATIC HMI software package for<br />

<strong>PC</strong> WinCC Runtime Advanced support the following protocols<br />

for the linking of control systems from other manufacturers:<br />

Allen Bradley<br />

- Ethernet IP protocol<br />

- DF1 protocol<br />

Mitsubishi<br />

- MC TCP/IP protocol<br />

- FX protocol<br />

Coupling overview<br />

Controller SIMATIC HMI<br />

Target hardware (PROTOCOL)<br />

(physics)<br />

Allen Bradley (Ethernet IP)<br />

via Ethernet TCP/IP network<br />

to max. 4 x controllers 2)<br />

ControlLogix 1756-L6x, -L6xS<br />

with Ethernet module<br />

1756-ENBT<br />

Guard Logix System<br />

CompactLogix 1769-L2xE,<br />

-L3xE<br />

CompactLogix 1769-L4x with<br />

ETHERNET module<br />

1768-ENBT<br />

SLC 5/05<br />

MicroLogix 1100, 1400<br />

Allen Bradley (DF1)<br />

to max. 1 x controller<br />

SLC 5/03, /04, /05<br />

MicroLogix (RS 232)<br />

to max. 1 x controller<br />

PLC5/11, /20, /30, /40, /60, /<strong>80</strong><br />

(RS 232)<br />

via KF2 gateway and DH+<br />

network to max. 4 x controllers 2)<br />

SLC 5/04<br />

PLC5/11, /20, /30, /40, /60, /<strong>80</strong><br />

(RS 232)<br />

via KF2 gateway and DH+<br />

network to max. 4 x controllers 2)<br />

SLC 5/04<br />

PLC5/11, /20, /30, /40, /60, /<strong>80</strong><br />

(RS 422)<br />

via KF3 gateway and DH485<br />

network to max. 4 x controllers 2)<br />

SLC 500<br />

MicroLogix (RS 232)<br />

System interface possible<br />

– System interface not possible<br />

1) Mobile Panel connection via special connecting cable and terminal<br />

box (see Mobile Panel), see Manual for cable layout.<br />

2) The following listed controllers can be combined as required<br />

3) Only Basic Panel PN, TP 177B DP/PN, OP 177B DP/PN,<br />

Mobile Panel 177 PN<br />

4) For Basic Panel, Touch Panel, Operator Panel, Comfort Panel,<br />

Multi Panel, the RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is<br />

required<br />

5) Not Basic Panel PN, Mobile Panel 177 PN<br />

2/194<br />

OP 77A<br />

TP 177A<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

– 3) 3)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Modicon<br />

- Modbus TCP/IP protocol<br />

- Modbus RTU protocol<br />

Omron<br />

- Link/Multi-Link protocol<br />

The following table contains more detailed information.<br />

Basic Panel Comfort Panel OP 77B<br />

TP 177B DP<br />

OP 177B DP<br />

TP 177B DP/PN<br />

OP 177B DP/PN<br />

Mobile Panel 177 DP 1)<br />

Mobile Panel 177 PN 1)<br />

TP 277<br />

OP 277<br />

Mobile Panel 277 1)<br />

MP 177<br />

MP 277<br />

MP 377<br />

4) 4) 5) 4) 4) 5) 4) 6)<br />

4) 4) 5) 4) 4) 5) 4) 7)<br />

WinCC<br />

Runtime<br />

Advanced<br />

4) 4) 5) 4) 4) 5) 4) 7) 8)<br />

5) 5) –<br />

4) 4) 5) 4) 4) 5) 4) 7) 8)<br />

6) Connection via Allen Bradley <strong>PC</strong> cable 1747 CP3<br />

7) Connection via Allen Bradley <strong>PC</strong> cable 1784 CP10<br />

8) For connection to KF2/KF3 gateway, a gender-changer<br />

(25-pin socket/25-pin socket) is required on the gateway side<br />

Note:<br />

For detailed information on pin assignment, refer to Online Help<br />

of WinCC; see also FAQs:<br />

http://support.automation.siemens.com/WW/view/en/29034071


■ Overview (continued)<br />

Controller SIMATIC HMI<br />

Target hardware<br />

(PROTOCOL) (physics)<br />

Mitsubishi (MC TCP/IP)<br />

via Ethernet IP network<br />

to max. 4 x controllers 2)<br />

–<br />

FX series FX3G, FX3U,<br />

FX3UC with Ethernet module<br />

FX3U ENET,<br />

Series Q with Ethernet<br />

module QJ71E71-100<br />

iQ series/QnUD QnUDEH<br />

3) 3)<br />

Mitsubishi FX (serial)<br />

to max. 1 x controller<br />

FX series FX1N, FX2N<br />

(RS 232)<br />

System interface possible<br />

– System interface not possible<br />

OP 77A<br />

TP 177A<br />

1) Mobile Panel connection via special connecting cable and terminal<br />

box (see Mobile Panel), see Manual for cable layout.<br />

2) The following listed controllers can be combined as required<br />

3) Only Basic Panel PN, TP 177B DP/PN, OP 177B DP/PN,<br />

Mobile Panel 177 PN<br />

4) Not Basic Panel PN, Mobile Panel 177 PN<br />

5) Connection using a Mitsubishi <strong>PC</strong> cable SC-09 with integrated level<br />

converter RS 232/RS422<br />

Note:<br />

For detailed information on pin assignment, refer to Online Help<br />

of WinCC; see also FAQs:<br />

http://support.automation.siemens.com/WW/view/en/29034071<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

System interfaces with WinCC (TIA Portal)<br />

Basic Panel Comfort Panel OP 77B<br />

TP 177B DP<br />

OP 177B DP<br />

TP 177B DP/PN<br />

OP 177B DP/PN<br />

Mobile Panel 177 DP 1)<br />

Mobile Panel 177 PN 1)<br />

Third-party controllers<br />

TP 277<br />

OP 277<br />

Mobile Panel 277 1)<br />

MP 177<br />

MP 277<br />

MP 377<br />

4) 4) 5)<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

WinCC Runtime<br />

Advanced<br />

2/195<br />

2


2<br />

Operator panels<br />

System interfaces with WinCC (TIA Portal)<br />

Third-party controllers<br />

■ Overview (continued)<br />

Controller SIMATIC HMI<br />

Target hardware<br />

(PROTOCOL) (physics)<br />

Modicon (MODBUS TCP/IP)<br />

Via MODBUS TCP/IP network<br />

to max. 4 x controllers 2)<br />

Concept Quantum,<br />

Unity Quantum<br />

Momentum<br />

Premium (TSX57)<br />

TSX Micro (TSX37)<br />

Modicon M340 20x0<br />

(except 2010)<br />

Via TCP/IP Modbus Plus<br />

Bridge 174 CEV 200 40 and<br />

MODBUS PLUS network to<br />

max. 4 x controllers 2)<br />

Concept Quantum,<br />

Unity Quantum<br />

Momentum<br />

Compact<br />

Modicon (MODBUS RTU)<br />

to max. 1 x controller<br />

Concept Quantum<br />

Momentum<br />

Compact<br />

(RS 232)<br />

Via bridge BM85-000 or PLC<br />

with bridge functionality and<br />

MODBUS PLUS network to<br />

max. 4 x controllers 2)<br />

Concept Quantum<br />

Compact (RS 232)<br />

System interface possible<br />

– System interface not possible<br />

1) Mobile Panel connection via special connecting cable and terminal<br />

box (see Mobile Panel), see Manual for cable layout.<br />

2) The following listed controllers can be combined as required<br />

3) Only Basic Panel PN, TP 177B DP/PN, OP 177B DP/PN,<br />

Mobile Panel 177 PN<br />

4) For Basic Panel, Touch Panel, Operator Panel, Comfort Panel,<br />

Multi Panel, the RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is<br />

required<br />

5) Not Basic Panel PN, Mobile Panel 177 PN<br />

Note:<br />

For detailed information on pin assignment, refer to Online Help<br />

of WinCC; see also FAQs:<br />

http://support.automation.siemens.com/WW/view/en/29034071<br />

2/196<br />

OP 77A<br />

TP 177A<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

– 3) 3)<br />

– 3) 3)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Basic Panel Comfort Panel OP 77B<br />

TP 177B DP<br />

OP 177B DP<br />

TP 177B DP/PN<br />

OP 177B DP/PN<br />

Mobile Panel 177 DP 1)<br />

Mobile Panel 177 PN 1)<br />

4) 4) 5) 4) 4) 5) 4)<br />

4) 4) 5) 4) 4) 5) 4)<br />

TP 277<br />

OP 277<br />

Mobile Panel 277 1)<br />

MP 177<br />

MP 277<br />

MP 377<br />

WinCC Runtime<br />

Advanced


■ Overview (continued)<br />

Controller SIMATIC HMI<br />

Target hardware<br />

(PROTOCOL) (physics)<br />

Omron (Link/MultiLink)<br />

to max. 1 x controller<br />

CP1L, CP1H, CP1E<br />

CJ1M, CJ1H, CJ1G<br />

CJ2H<br />

CS1G, CS1H, CS1D<br />

CP2MC (RS232)<br />

Via converter NT-AL001 and<br />

RS422 network to max.<br />

4 x controllers 2)<br />

CP1L, CP1H, CP1E<br />

CJ1M, CJ1H, CJ1G<br />

CJ2H<br />

CS1G, CS1H, CS1D<br />

CP2MC (RS232)<br />

Via RS422 network to max.<br />

4 x controllers 2)<br />

CP1L, CP1H, CP1E<br />

CJ1M, CJ1H, CJ1G<br />

(RS 422)<br />

Via RS422 network to max.<br />

4 x controllers 2)<br />

CJ2H<br />

CS1G, CS1H, CS1D<br />

CP2MC (RS422)<br />

System interface possible<br />

– System interface not possible<br />

OP 77A<br />

TP 177A<br />

– –<br />

– –<br />

1) Mobile Panel connection via special connecting cable and terminal<br />

box (see Mobile Panel), see Manual for cable layout.<br />

2) The controllers listed below can be combined in any way required;<br />

connection via RS422 interface of the controller or via RS422 module<br />

3) For Basic Panel, Touch Panel, Operator Panel, Comfort Panel,<br />

Multi Panel, the RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is<br />

required<br />

4) Not Basic Panel PN, Mobile Panel 177 PN<br />

Note:<br />

For detailed information on pin assignment, refer to Online Help<br />

of WinCC; see also FAQs:<br />

http://support.automation.siemens.com/WW/view/en/29034071<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

System interfaces with WinCC (TIA Portal)<br />

Basic Panel Comfort Panel OP 77B<br />

TP 177B DP<br />

OP 177B DP<br />

TP 177B DP/PN<br />

OP 177B DP/PN<br />

Mobile Panel 177 DP 1)<br />

Mobile Panel 177 PN 1)<br />

3) 3) 4) 3)<br />

3) 3) 4) 3)<br />

Third-party controllers<br />

TP 277<br />

OP 277<br />

Mobile Panel 277 1)<br />

MP 177<br />

MP 277<br />

MP 377<br />

5) 4) 4) –<br />

– – – 4) 4) –<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

WinCC Runtime<br />

Advanced<br />

2/197<br />

2


2<br />

Operator panels<br />

HMI Accessories<br />

Industrial USB Hub 4<br />

■ Overview<br />

Industrial USB Hub 4, open<br />

The Industrial USB Hub 4 is used as a USB hub for the<br />

connection of I/O devices to Multi Panels, Panel <strong>PC</strong>s and<br />

standard <strong>PC</strong>s.<br />

The industrial USB Hub 4 with IP65 degree of protection on the<br />

front (Service Kit required) can be mounted in a control<br />

cabinet. This simplifies the use of USB I/O in harsh industrial<br />

environments.<br />

USB I/O can be connected to the panel and operated via the<br />

Industrial USB Hub 4 without opening the cabinet door. The<br />

ports are also accessible from the rear even in the control<br />

cabinet.<br />

■ Design<br />

■ Ordering data<br />

Industrial USB Hub 4 A<br />

Order No.<br />

6AV6 671-3AH00-0AX0<br />

Use of the Industrial USB Hub 4<br />

4 x USB 2.0, IP65, for control<br />

permits the simultaneous connection of as many as four<br />

I/O devices such as USB stick, mouse, keyboard, printer or<br />

barcode reader to the panel.<br />

cabinet door or standard rail,<br />

usable with MP 177/MP 277/<br />

MP 377, Panel <strong>PC</strong>s, HMI I<strong>PC</strong>s<br />

and standard <strong>PC</strong>s<br />

increases the availability of the system to be operated. The<br />

cabinet door no longer has to be opened in order to connect<br />

Service pack for Industrial USB<br />

Hub 4<br />

see HMI accessories service<br />

packets (incl. IP65 expansion)<br />

to the I/O. The unit can be operated from the Panel <strong>PC</strong> and<br />

the Multi Panel without interruption.<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

In addition, the Industrial USB Hub4 has the following features:<br />

Inspection window for each interface<br />

■ More information<br />

Vibration-proof restraint of connected USB cables and Note for SIMATIC Panel <strong>PC</strong>s<br />

USB sticks<br />

One LED per interface for checking the data traffic<br />

The Industrial USB Hub 4 is approved for the Windows<br />

CE/2000/XP operating systems. The appropriate drivers are<br />

Sufficient interior space for easy insertion and removal of<br />

connections<br />

Facility for attachment to a DIN rail<br />

Voltage connection for 24 V DC<br />

■ Integration<br />

The Industrial USB Hub 4 is suitable for connection to:<br />

Multi Panels<br />

SIMATIC I<strong>PC</strong><br />

Standard <strong>PC</strong><br />

Recommended operating systems:<br />

Windows CE/2000/XP/XP embedded<br />

supplied with the operating system software.<br />

2/198<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Technical specifications<br />

6AV6 671-3AH00-0AX0<br />

Product type designation Industrial USB Hub 4<br />

Supply voltage<br />

Supply voltage 24 V DC<br />

permissible range +20.4 V to +28.8 V DC<br />

Ambient conditions<br />

max. relative humidity 90 %<br />

Temperature<br />

Operation (vertical installation) 0 °C to +50 °C<br />

Transport, storage -20 °C to +60 °C<br />

Degree of protection<br />

IP65 at front Yes<br />

IP20 rear Yes<br />

Certifications & standards<br />

Certifications CE<br />

Interfaces<br />

Number of USB interfaces 4; 500 mA each, e.g. mouse,<br />

keyboard, printer, USB stick<br />

General information<br />

belongs to product/product range MP 277, Panel <strong>PC</strong><br />

Dimensions<br />

External dimensions (W x H x D) in 212 x 156 x 50<br />

mm<br />

Dimensions and weight<br />

Weight<br />

Weight 0.5 kg


■ Overview<br />

Example - connecting cables<br />

S5-TTY<br />

(PG-S5)<br />

6ES5 734-<br />

2xxxx<br />

S5-TTY<br />

(TD/OP-<br />

S5) (15/15pole)<br />

6XV1 440-<br />

2Axxx<br />

S7 PG702 RS232<br />

external<br />

(15/9-pole)<br />

6ES7 705-<br />

0AA00-<br />

7BA0<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6XV1 440-<br />

2Kxxx<br />

Operator panels<br />

HMI Accessories<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Connecting cables<br />

Key<br />

P = PROCESS COUPLING<br />

K = optional process coupling (option required)<br />

D = DOWNLOAD (update operating system, project, …)<br />

U = booting (factory setting in the case of a missing or damaged<br />

operating system)<br />

MBP = Mobile Panel<br />

You can find order numbers for the connecting cables required<br />

to link SIMATIC Panels under selection and ordering data.<br />

TD-PPI<br />

(incl.<br />

voltage)<br />

6ES7 901-<br />

3EB10-<br />

0XA0<br />

RS232<br />

zero<br />

modem<br />

6ES7 901-<br />

1BF00-<br />

0XA0<br />

RS232/PPI<br />

multimaster<br />

cable<br />

6ES7 901-<br />

3CB30-0XA0<br />

USB/PPI<br />

multimaster<br />

cable<br />

6ES7 901-<br />

3DB30-0XA0<br />

Key Panel<br />

KP8/KP8F<br />

- - - - - - - - -<br />

PP7 - - - - - - - - -<br />

PP17 I - - - - - - - - -<br />

PP17-II - - - - - - - - -<br />

KTP400 mono PN - - - - - - - - -<br />

KTP600 mono PN - - - - - - - - -<br />

KTP600 color DP - - - - - - D/U D/U P/D<br />

KTP600 color PN - - - - - - - - -<br />

KTP1000 color<br />

DP<br />

- - - - - - D/U D/U P/D<br />

KTP1000 color<br />

PN<br />

- - - - - - - - -<br />

KTP1500 color<br />

PN<br />

- - - - - - - - -<br />

KTP400 Comfort - - - - - - - - P/D<br />

TP700 Comfort - - - - - - - - P/D<br />

TP900 Comfort - - - - - - - - P/D<br />

TP1200 Comfort - - - - - - - - P/D<br />

KP400 Comfort - - - - - - - - P/D<br />

KP700 Comfort - - - - - - - - P/D<br />

KP900 Comfort - - - - - - - - P/D<br />

KP1200 Comfort - - - - - - - - P/D<br />

MPI<br />

(PG-S7) to<br />

187.5<br />

kbaud<br />

6ES7 901-<br />

0BF00-<br />

0AA0<br />

2/199<br />

2


Operator panels<br />

HMI Accessories<br />

Connecting cables<br />

■ Overview (continued)<br />

2 MBP 177 - - - - - - D/U - -<br />

MBP 277 - - - - - - D/U - -<br />

TD200 - - - - P - D/U - P<br />

TD400C - - - - P - D/U - P<br />

OP73micro - - - - P - D/U D/U P<br />

TP177micro - - - - - - D/U D/U -<br />

OP73 - - - - P - D/U D/U P/D<br />

OP77A - - - - - - D/U D/U P/D<br />

OP77B - - P - D/U - - P/D<br />

TP177A - - - - - - D/U D/U P/D<br />

TP177B - - - P 3) - - D/U - P/D<br />

TP177B 4" - - - P 3) - D D - P/D<br />

OP177B - - - P 3) - - D/U - P/D<br />

TP277-6 - - - P 3) - - D/U - P/D<br />

OP277-6 - - - P 3) - - D/U - P/D<br />

MP177-6 T - - - P 3) - - D/U - P/D<br />

MP277-8 T - - - P 3) - - D/U - P/D<br />

MP277-10 T - - - P 3) - - D/U - P/D<br />

MP377-12 T - - - P 3) - - D - P/D<br />

MP377-15 T - - - P 3) - - D - P/D<br />

MP377-19 T - - - P 3) - - D - P/D<br />

2/200<br />

S5-TTY<br />

(PG-S5)<br />

6ES5 734-<br />

2xxxx<br />

S5-TTY<br />

(TD/OP-<br />

S5) (15/15pole)<br />

6XV1 440-<br />

2Axxx<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

S7 PG702 RS232<br />

external<br />

(15/9-pole)<br />

6ES7 705-<br />

0AA00-<br />

7BA0<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6XV1 440-<br />

2Kxxx<br />

TD-PPI<br />

(incl.<br />

voltage)<br />

6ES7 901-<br />

3EB10-<br />

0XA0<br />

RS232<br />

zero<br />

modem<br />

6ES7 901-<br />

1BF00-<br />

0XA0<br />

RS232/PPI<br />

multimaster<br />

cable<br />

6ES7 901-<br />

3CB30-0XA0<br />

USB/PPI<br />

multimaster<br />

cable<br />

6ES7 901-<br />

3DB30-0XA0<br />

MPI<br />

(PG-S7) to<br />

187.5<br />

kbaud<br />

6ES7 901-<br />

0BF00-<br />

0AA0


■ Overview (continued)<br />

DP PtP DP<br />

Standard<br />

6XV1 830-<br />

0Axxx<br />

Standard<br />

PROFIBUS<br />

(2-contact)<br />

DP<br />

(Mobile<br />

Panel)<br />

6XV1 440-<br />

4Axxx<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

PN<br />

(cross<br />

cable) 2)<br />

Point-topoint<br />

6XV1 870-<br />

3RH20<br />

PN<br />

(standard<br />

cable) 2)<br />

Standard<br />

Ethernet<br />

CAT5<br />

PN<br />

(Mobile<br />

Panel)<br />

6XV1 440-<br />

4Bxxx<br />

Operator panels<br />

HMI Accessories<br />

Conv.<br />

RS422-<br />

RS232<br />

6AV6 671-<br />

8XE00-0AX0<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Connecting cables<br />

Conv.<br />

RS232-TTY<br />

(20 mA)<br />

6ES5 734-<br />

1BD20<br />

Key Panel<br />

KP8/KP8F<br />

- - - P/D P/D - - - -<br />

PP7 P P - - - - - - -<br />

PP17 I P P - - - - - - -<br />

PP17-II P P - - - - - - -<br />

KTP400 mono PN - - - P/D/U P/D/U - - - -<br />

KTP600 mono PN - - - P/D/U P/D/U - - - -<br />

KTP600 color DP P/D P/D - - - - - - P/D/U<br />

KTP600 color PN - - - P/D/U P/D/U - - - -<br />

KTP1000 color<br />

DP<br />

P/D P/D - - - - - - P/D/U<br />

KTP1000 color<br />

PN<br />

- - - P/D/U P/D/U - - - -<br />

KTP1500 color<br />

PN<br />

- - - P/D/U P/D/U - - - -<br />

KTP400 Comfort P/D P/D - P/D/U P/D/U - - - P/D/U<br />

TP700 Comfort P/D P/D - P/D/U P/D/U - - - P/D/U<br />

TP900 Comfort P/D P/D - P/D/U P/D/U - - - P/D/U<br />

TP1200 Comfort P/D P/D - P/D/U P/D/U - - - P/D/U<br />

KP400 Comfort P/D P/D - P/D/U P/D/U - - - P/D/U<br />

KP700 Comfort P/D P/D - P/D/U P/D/U - - - P/D/U<br />

KP900 Comfort P/D P/D - P/D/U P/D/U - - - P/D/U<br />

KP1200 Comfort P/D P/D - P/D/U P/D/U - - - P/D/U<br />

MBP 177 DP P/D P/D P/D - - - - - -<br />

MBP 177 PN - - - - - P/D - - -<br />

MBP 277 P/D P/D P/D - - P/D - - -<br />

TD200 - - - - - - - - -<br />

TD400C - - - - - - - - -<br />

OP73micro P - - - - - - - -<br />

TP177micro P P - - - - - - P/D/U<br />

OP73 P P - - - - - - -<br />

OP77A P P - - - - - - P/D/U<br />

OP77B P/D P/D - - - - - P P/D/U<br />

TP177A P P - - - - - - P/D/U<br />

TP177B DP P/D P/D - - - - P - P/D/U<br />

TP177B PN/DP P/D P/D - P/D P/D - P - P/D/U<br />

TP177B 4" P/D P/D - P/D/U P/D/U - P - P/D/U<br />

OP177B DP P/D P/D - - - - P - P/D/U<br />

90°<br />

angular<br />

(9-pin 1:1)<br />

6AV6 671-<br />

8XD00-<br />

0AX0<br />

2/201<br />

2


2<br />

Operator panels<br />

HMI Accessories<br />

Connecting cables<br />

■ Overview (continued)<br />

OP177B PN/DP P/D P/D - P/D P/D - P - P/D/U<br />

TP277-6 P/D P/D - P/D P/D - P - P/D/U<br />

OP277-6 P/D P/D - P/D P/D - P - P/D/U<br />

MP177-6 T P/D P/D - P/D P/D - P - P/D/U<br />

MP277-8 T P/D P/D - P/D P/D - P - P/D/U<br />

MP277-8 K P/D P/D - P/D P/D - P - P/D/U<br />

MP277-10 T P/D P/D - P/D P/D - P - P/D/U<br />

MP277-10 K P/D P/D - P/D P/D - P - P/D/U<br />

MP377-12 T P/D P/D - P/D/U P/D/U - P - P/D<br />

MP377-12 K P/D P/D - P/D/U P/D/U - P - P/D<br />

MP377-15 T P/D P/D - P/D/U P/D/U - P - P/D<br />

MP377-19 T P/D P/D - P/D/U P/D/U - P - P/D<br />

Note:<br />

This table is for basic orientation only. Technical characteristics<br />

are described in the communication manual or in the respective<br />

user manual.<br />

1) With gender changer<br />

2) PROFINET IRT (Isochronous Runtime); isochronous mode only<br />

possible with IRT-enabled switch<br />

3) Only in conjunction with the RS422/RS232 converter<br />

2/202<br />

DP PtP DP<br />

Standard<br />

6XV1 830-<br />

0Axxx<br />

Standard<br />

PROFIBUS<br />

(2-contact)<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

DP<br />

(Mobile<br />

Panel)<br />

6XV1 440-<br />

4Axxx<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

PN<br />

(cross<br />

cable) 2)<br />

Point-topoint<br />

6XV1 870-<br />

3RH20<br />

PN<br />

(standard<br />

cable) 2)<br />

Standard<br />

Ethernet<br />

CAT5<br />

PN<br />

(Mobile<br />

Panel)<br />

6XV1 440-<br />

4Bxxx<br />

Conv.<br />

RS422-<br />

RS232<br />

6AV6 671-<br />

8XE00-0AX0<br />

Conv.<br />

RS232-TTY<br />

(20 mA)<br />

6ES5 734-<br />

1BD20<br />

90°<br />

angular<br />

(9-pin 1:1)<br />

6AV6 671-<br />

8XD00-<br />

0AX0


1) Included in PG scope of delivery<br />

2) Other cable lengths (3.2 m, 5 m, 10 m, 20 m, 32 m and 50 m) see<br />

length key in Appendix.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

HMI Accessories<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Connecting cables<br />

■ Ordering data Order No. Order No.<br />

Connecting cables 6ES7 901-0....<br />

for SIMATIC S7<br />

MPI cable between<br />

SIMATIC S7 and programming<br />

device via MPI max. 187.5 kbaud<br />

Standard length<br />

5.0 m 1) 6ES7 901-0BF00-0AA0<br />

Connecting cables<br />

6ES7 901-1BF00-0XA0<br />

Between the HMI adapter and<br />

<strong>PC</strong>/TS adapter (RS 232 cable/<br />

null-modem cable) for OP77B,<br />

TP177A/B, OP177B, TP/OP270,<br />

MP270, MP370<br />

5.0 m<br />

Connecting cables 6ES7 901-3....<br />

Process connecting cable<br />

6ES7 901-1BF00-0XA0<br />

6ES7 901-3EB10-0XA0<br />

For connecting TD 100C or<br />

TD 200C to S7-200<br />

Connecting cables 6XV1 440-2A...<br />

Connecting cable between<br />

TD/TP/OP and PLC S5-90U to<br />

S5-155U<br />

max. 1,000.0 m 2) PROFIBUS connecting cable<br />

830-1C<br />

For connection of data terminal,<br />

precut/preassembled with two sub<br />

D connectors, 9-pin, terminated at<br />

both ends<br />

for PP, OP 73micro, TP 070, OP73,<br />

TP 170micro, TP 177micro,<br />

OP 77A/B, TP 170A, TP 177A,<br />

TP/OP 170B, TP/OP 177B,<br />

MP 270B<br />

1.5 m<br />

3.0 m<br />

6XV1 830-1CH15<br />

6XV1 830-1CH30<br />

USB/PPI multi-master cable 6ES7 901-3DB30-0XA0<br />

For connecting the S7-200 to the<br />

serial <strong>PC</strong>/OP interface<br />

PROFIBUS FC Standard Cable<br />

For connection to PPI;<br />

6XV1 830-0EH10<br />

standard type with special design<br />

for quick mounting, 2-core,<br />

shielded, sold by the meter, max.<br />

delivery unit 1000 m, minimum<br />

ordering quantity 20 m<br />

Industrial Ethernet TX XP Cord<br />

RJ45/RJ45<br />

6XV1 440-2A...<br />

Crossed TP cable 4 x 2, preassembled<br />

with 2 x RJ45 connectors<br />

1.0 m 6XV1 870-3RH10<br />

6.0 m 6XV1 870-3RH60<br />

10.0 m 6XV1 870-3RN10<br />

Note:<br />

Cable pin assignments can be found on the Internet in the online<br />

help of WinCC flexible and under FAQs.<br />

2/203<br />

2


2<br />

Operator panels<br />

HMI Accessories<br />

RS485 bus connector<br />

■ Overview<br />

2/204<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Used for connecting PROFIBUS nodes to the PROFIBUS<br />

bus cable<br />

Easy installation<br />

FastConnect plugs ensure extremely short assembly times<br />

due to their insulation-displacement technology<br />

Integrated terminating resistors (not in the case of<br />

6ES7 972-0BA30-0XA0)<br />

PG connection with special bus connector possible without<br />

additional installation of network nodes.<br />

■ Ordering data Order No. Order No.<br />

RS485 bus connector with axial<br />

cable outlet (1<strong>80</strong>°)<br />

For industrial <strong>PC</strong>,<br />

SIMATIC HMI OP, OLM;<br />

max. transmission rate 12 Mbit/s<br />

SIPLUS DP PB RS485<br />

connector with axial cable<br />

outlet (1<strong>80</strong>°)<br />

6GK1 500-0EA02<br />

6AG1 500-0EA02-2AA0<br />

for extended temperature range<br />

-25 °C ... +60 °C and medial<br />

exposure;<br />

Based on 6GK1 500-0EA02<br />

RS485 bus connector with<br />

cable outlet (90°)<br />

With screw-terminals, max.<br />

transmission rate 12 Mbit/s<br />

Without PG interface 6ES7 972-0BA12-0XA0<br />

With PG interface 6ES7 972-0BB12-0XA0<br />

SIPLUS DP PB RS485<br />

connector with 90° cable outlet<br />

for extended temperature range<br />

-25 … + 60 °C and medial<br />

exposure<br />

without PG interface<br />

6AG1 972-0BA12-2XA0<br />

Based on<br />

6ES7 972-0BA12-0XA0<br />

with PG interface<br />

6AG1 972-0BB12-2XA0<br />

Based on<br />

6ES7 972-0BB12-0XA0<br />

RS485 bus connector with<br />

angled cable outlet (35°)<br />

With screw-terminals, max.<br />

transmission rate 12 Mbit/s<br />

Without PG interface 6ES7 972-0BA42-0XA0<br />

With PG interface 6ES7 972-0BB42-0XA0<br />

SIPLUS DP PB RS485<br />

connector with inclined cable<br />

outlet (35°)<br />

for extended temperature range<br />

-25 … + 60 °C and medial<br />

exposure<br />

without PG interface<br />

6AG1 972-0BA41-2XA0<br />

Based on<br />

6ES7 972-0BA41-0XA0<br />

with PG interface<br />

6AG1 972-0BB41-2XA0<br />

Based on<br />

6ES7 972-0BB41-0XA0<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

RS485 bus connector with 6ES7 972-0BA30-0XA0<br />

cable outlet (30°)<br />

With screw-terminals, low-cost<br />

version, max. transmission rate<br />

1.5 Mbit/s<br />

PROFIBUS bus connector<br />

RS485 with FastConnect<br />

technology<br />

PROFIBUS FastConnect bus<br />

connector RS485 with 90° cable<br />

outlet<br />

with insulation displacement<br />

terminals, max. transmission rate<br />

12 Mbit/s<br />

Without PG interface<br />

1 unit 6ES7 972-0BA52-0XA0<br />

100 units 6ES7 972-0BA52-0XB0<br />

With PG interface<br />

1 unit 6ES7 972-0BB52-0XA0<br />

100 units 6ES7 972-0BB52-0XB0<br />

PROFIBUS FastConnect<br />

RS485 bus connector with<br />

angled cable outlet (35°)<br />

with insulation displacement<br />

terminals, max. transmission rate<br />

12 Mbit/s<br />

Without PG interface 6ES7 972-0BA60-0XA0<br />

With PG interface 6ES7 972-0BB60-0XA0<br />

PROFIBUS FastConnect bus 6GK1 500-0FC10<br />

connector RS485 Plug 1<strong>80</strong><br />

with insulation displacement<br />

terminals, with 1<strong>80</strong>° cable outlet,<br />

for industrial <strong>PC</strong>,<br />

SIMATIC HMI OP, OLM;<br />

max. transmission rate 12 Mbit/s<br />

SIMATIC S5/S7 plug-in cable for 6ES7 901-4BD00-0XA0<br />

PROFIBUS<br />

Preassembled with two 9-pin<br />

sub-D connectors; max.<br />

transmission rate 12 Mbit/s; 3 m


■ Overview<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

HMI Accessories<br />

IE FC RJ45 Plug 2 x 2<br />

Implementation of direct device connections over distances of<br />

up to 100 m with Industrial Ethernet FC installation cable 2 x 2<br />

without patching<br />

Easy connection (insulation displacement contacts) for 4-core<br />

Twisted Pair installation cables (100 Mbit/s) without the need<br />

for special tools<br />

Error-preventing connection technique thanks to visible<br />

connection area as well as colored blade terminals<br />

Industry-compatible design (rugged metal housing, no easily<br />

lost small parts)<br />

Excellent EMC shielding and deflection (metal housing)<br />

Integrated strain-relief for installation cables<br />

Compatible to the EN 50173 (RJ45) / ISO IEC 11<strong>80</strong>1 standard<br />

Additional strain and bending relief of plug connector possible<br />

through latching of plug on device housing,<br />

e.g. with SCALANCE X, SCALANCE S, ET 200S.<br />

■ Ordering data Order No. Order No.<br />

IE FC RJ45 plugs<br />

IE FC TP Standard Cable<br />

RJ45 plug connector for Industrial<br />

GP 2x2 (TypeA)<br />

Ethernet with a rugged metal<br />

4-core, shielded TP installation<br />

housing and integrated insulation<br />

cable for connection to<br />

displacement contacts for<br />

IE FC Outlet RJ45/ IE FC RJ45<br />

connecting Industrial Ethernet FC<br />

Plug; PROFINET-compatible;<br />

installation cables<br />

with UL approval;<br />

IE FC RJ45 Plug 1<strong>80</strong><br />

Sold by the meter<br />

1<strong>80</strong>° cable outlet; for network<br />

max. quantity 1,000 m;<br />

6XV1 840-2AH10<br />

components and CPs/CPUs with<br />

minimum order 20 m<br />

Industrial Ethernet interface<br />

1 pack = 1 item<br />

1 pack = 10 items<br />

6GK1 901-1BB10-2AA0<br />

6GK1 901-1BB10-2AB0<br />

Preferred length<br />

1000 m 6XV1 840-2AU10<br />

1 pack = 50 items<br />

IE FC RJ45 Plug 90<br />

90° cable outlet; e.g. for ET 200S<br />

6GK1 901-1BB10-2AE0<br />

IE FC TP Flexible Cable<br />

GP 2x2 (TypeB)<br />

4-core, shielded TP installation<br />

cable for connection to<br />

6XV1 870-2B<br />

1 pack = 1 item 6GK1 901-1BB20-2AA0<br />

IE FC Outlet RJ45/ IE FC RJ45<br />

1 pack = 10 items<br />

1 pack = 50 items<br />

6GK1 901-1BB20-2AB0<br />

6GK1 901-1BB20-2AE0<br />

Plug for occasional movement;<br />

PROFINET-compatible;<br />

with UL approval;<br />

IE FC RJ45 Plug 145<br />

sold by the meter; max. quantity<br />

145° cable outlet; e.g. for<br />

SIMOTION and SINAMICS<br />

1000 m,<br />

minimum order 20 m<br />

1 pack = 1 item 6GK1 901-1BB30-0AA0<br />

1 pack = 10 items 6GK1 901-1BB30-0AB0<br />

1 pack = 50 items 6GK1 901-1BB30-0AE0<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/205<br />

2


2<br />

Operator panels<br />

HMI Accessories<br />

Accessories for SIMATIC Mobile Panels<br />

■ Overview<br />

Connecting cable DP (PROFIBUS) for Mobile Panels<br />

Connecting cable PN (PROFINET) for Mobile Panels<br />

Device for wall fastening for Mobile Panel, front and side view<br />

2/206<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Replacement key for Mobile Panel<br />

Option package: Battery for Mobile Panels


Operator panels<br />

HMI Accessories<br />

Accessories for SIMATIC Mobile Panels<br />

■ Ordering data Order No. Order No.<br />

Connecting cable DP<br />

(MPI/PROFIBUS) for<br />

Mobile Panels<br />

Standard lengths<br />

2 m 6XV1 440-4AH20<br />

5 m 6XV1 440-4AH50<br />

8 m 6XV1 440-4AH<strong>80</strong><br />

10 m 6XV1 440-4AN10<br />

15 m 6XV1 440-4AN15<br />

20 m 6XV1 440-4AN20<br />

25 m<br />

Connecting cable PN<br />

(PROFINET) for Mobile Panels<br />

Standard lengths<br />

6XV1 440-4AN25<br />

2 m 6XV1 440-4BH20<br />

5 m 6XV1 440-4BH50<br />

8 m 6XV1 440-4BH<strong>80</strong><br />

10 m 6XV1 440-4BN10<br />

15 m 6XV1 440-4BN15<br />

20 m 6XV1 440-4BN20<br />

25 m 6XV1 440-4BN25<br />

Accumulator option pack for<br />

Mobile Panels (DP and PN)<br />

6AV6 671-5AD00-0AX0<br />

Wall mounting bracket for<br />

Mobile Panels<br />

6AV6 574-1AF04-4AA0<br />

Memory card Multi Media Card, A<br />

128 MB<br />

6AV6 671-1CB00-0AX2<br />

Touch pen<br />

including nylon line for securing it<br />

to the Mobile Panel 277 10" (set of<br />

5, packed ready for shipping)<br />

A 6AV6 645-7AB14-0AS0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical<br />

specifications.<br />

100.7<br />

SIMATIC Mobile Panel wall-mounting bracket<br />

8°<br />

8°<br />

24.6<br />

2<br />

18<br />

225.2<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00047<br />

Labeling strips for keys<br />

Pack for labeling 6 devices<br />

(2 sheets of 3 sets)<br />

incl. spare labels for cover caps<br />

6AV6 671-5BF00-0AX0<br />

Spare key for Mobile Panels<br />

(pack of 10 keys)<br />

6AV6 574-1AG04-4AA0<br />

Service pack for<br />

Mobile Panels 177/277<br />

Consisting of:<br />

Blanking plugs for cable duct<br />

2 x cable glands for connectivity<br />

box<br />

1 set of screws for connectivity<br />

box cover<br />

2 x terminal box (12-pin)<br />

1 x terminal box (3-pin)<br />

1 x blanking cap for terminal box<br />

6AV6 574-1AA04-4AA0<br />

Service pack for<br />

Mobile Panels 277(F) IWLAN<br />

Consisting of:<br />

1 x Mobile Panel 277<br />

accessories pack (labeling strip<br />

cover)<br />

1 x battery slot cover (device)<br />

1 x backup battery<br />

1 x left/right cover (charging<br />

station)<br />

1 x power supply mating<br />

connector (charging station)<br />

1 x spare key (charging station)<br />

A 6AV6 671-5CA00-0AX2<br />

Extra battery 6AV6 671-5CL00-0AX0<br />

for Mobile Panel 277(F) IWLAN<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2/207<br />

2


2<br />

Operator panels<br />

HMI Accessories<br />

Terminal boxes<br />

■ Overview<br />

■ Technical specifications<br />

Product type designation Terminal box DP for Mobile<br />

Panels 177/277<br />

(MPI/PROFIBUS) Basic<br />

Expansions for operator<br />

control of the process<br />

Hot swapping with emergency stop circuit<br />

interruption<br />

2/208<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV6 671-5AE00-0AX0 6AV6 671-5AE10-0AX0 6AV6 671-5AE01-0AX0 6AV6 671-5AE11-0AX0<br />

Terminal box DP for Mobile<br />

Panels 177/277<br />

(MPI/PROFIBUS) Plus<br />

Terminal box PN for Mobile<br />

Panels 177/277<br />

(MPI/PROFINET) Basic<br />

Terminal box PN for Mobile<br />

Panels 177/277<br />

(MPI/PROFINET) Plus<br />

without emergency stop with emergency stop circuit without emergency stop<br />

circuit interruption<br />

interruption<br />

circuit interruption<br />

Monitoring the <strong>ST</strong>OP button No Yes No Yes<br />

Location identifier<br />

Supply voltage<br />

Via battery<br />

Yes Yes Yes Yes<br />

permissible range +20.4 V to +28.8 V DC +20.4 V to +28.8 V DC +20.4 V to +28.8 V DC +20.4 V to +28.8 V DC<br />

Supply voltage 24 V DC 24 V DC 24 V DC 24 V DC<br />

Rated current 0.4 A 0.5 A 0.4 A 0.5 A<br />

Power<br />

Interfaces<br />

10 W 12 W 10 W 12 W<br />

Interfaces 1 x RS232, 1 x RS422, 1 x RS232, 1 x RS422, 2 x Ethernet (RJ45) 2 x Ethernet (RJ45)<br />

Ambient conditions<br />

1 x RS485 (max. 12 Mbit/s) 1 x RS485 (max. 12 Mbit/s)<br />

Operation<br />

(vertical installation)<br />

0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °C<br />

Transport, storage -20 °C to +70 °C -20 °C to +70 °C -20 °C to +70 °C -20 °C to +70 °C<br />

max. relative humidity 85 % 85 % 85 % 85 %<br />

Enclosure according to<br />

EN 60529<br />

IP65 IP65 IP65 IP65<br />

Certifications<br />

Functionality under WinCC<br />

flexible/WinCC (TIA Portal)<br />

Applications/options<br />

CE, cULus, C-TICK CE, cULus, C-TICK CE, cULus, C-TICK CE, cULus, C-TICK<br />

Connection point identification<br />

Dimensions and weight<br />

Dimensions<br />

Yes Yes Yes Yes<br />

External dimensions<br />

(W x H x D) in mm<br />

Weight<br />

160 x 120 x 70 160 x 120 x 70 230 x 120 x <strong>80</strong> 230 x 120 x <strong>80</strong><br />

Weight 0.35 kg 0.4 kg 0.45 kg 0.5 kg


■ Ordering data Order No. ■ Dimensional drawings<br />

DP terminal box for<br />

Mobile Panels 177/277<br />

(MPI/PROFIBUS)<br />

Basic 6AV6 671-5AE00-0AX0<br />

Plus<br />

PN terminal box for<br />

Mobile Panels 177/277<br />

(PROFINET)<br />

A 6AV6 671-5AE10-0AX0<br />

Basic A 6AV6 671-5AE01-0AX0<br />

Plus A 6AV6 671-5AE11-0AX0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

HMI Accessories<br />

All specifications in mm. Panel cutout see technical<br />

specifications.<br />

140<br />

10<br />

160<br />

150<br />

43<br />

DP connection box for SIMATIC Mobile Panel<br />

230<br />

220<br />

210<br />

PN connection box for SIMATIC Mobile Panel<br />

11 0<br />

120<br />

142 ± 2<br />

10<br />

110<br />

76 120<br />

142 ± 2<br />

4.5<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Terminal boxes<br />

55<br />

62.7<br />

G_<strong>ST</strong><strong>80</strong>_XX_00045<br />

G_<strong>ST</strong><strong>80</strong>_XX_00273<br />

2/209<br />

2


2<br />

Operator panels<br />

HMI Accessories<br />

SIPLUS terminal boxes<br />

■ Overview<br />

Note:<br />

SIPLUS extreme products are based on <strong>Siemens</strong> Industry<br />

standard products. The contents listed here were taken from the<br />

respective standard products. SIPLUS extreme-specific information<br />

was added.<br />

2/210<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIPLUS terminal box<br />

DP Plus<br />

Order No. 6AG1 671-5AE10-4AX0<br />

Order No. based on 6AV6 671-5AE10-0AX0<br />

Ambient temperature range 0 ... +50 °C<br />

Conformal coating Coating of the printed circuit<br />

boards and the electronic<br />

components<br />

Technical specifications The technical data of the<br />

standard product applies except<br />

for the ambient conditions.<br />

Ambient conditions<br />

Relative humidity 5 … 100 %<br />

Condensation permissible<br />

Air pressure (depending on the<br />

highest positive temperature range<br />

specified)<br />

■ Ordering data Order No.<br />

SIPLUS terminal box<br />

DP Plus for<br />

Mobile Panels 177/277<br />

(MPI/PROFIBUS)<br />

10<strong>80</strong> ... 795 hPa<br />

(-1000 ... +2000m)<br />

see ambient temperature range<br />

795 ... 658 hPa<br />

(+2000 ... +3500m)<br />

derating 10 K<br />

658 … 540 hPa<br />

(+3500 … +5000m)<br />

derating 20 K<br />

A 6AG1 671-5AE10-4AX0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H


■ Overview<br />

■ Technical specifications<br />

6AV6 671-5CE00-0AX1<br />

Supply voltage<br />

Via battery<br />

permissible range +19.2 V to +28.8 V DC<br />

Supply voltage 24 V DC<br />

Rated current 3.2 A<br />

Power<br />

Ambient conditions<br />

77 W<br />

Operation (vertical installation) 0 °C to +40 °C<br />

Transport, storage -20 °C to +60 °C<br />

max. relative humidity 85 %<br />

IP65 at front Yes<br />

IP65 rear Yes<br />

Enclosure according to EN 60529 IP65<br />

Certifications<br />

Dimensions and weight<br />

Dimensions<br />

CE, cULus, C-TICK<br />

External dimensions (W x H x D) in<br />

mm<br />

Weight<br />

208 x 333 x 75<br />

Weight 1.1 kg<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

HMI Accessories<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Charging station<br />

■ Ordering data Order No.<br />

Charging station for<br />

Mobile Panels<br />

A 6AV6 671-5CE00-0AX1<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical<br />

specifications.<br />

343<br />

61 85<br />

Charging station<br />

160<br />

208<br />

198<br />

72<br />

G_<strong>ST</strong><strong>80</strong>_XX_00297<br />

2/211<br />

2


2<br />

Operator panels<br />

HMI Accessories<br />

Transponder<br />

■ Overview<br />

■ Technical specifications<br />

6AV6 671-5CM00-0AX1<br />

Supply voltage<br />

Via battery Yes<br />

Number of batteries 3<br />

Battery type Type AA<br />

-Type AA Yes<br />

Lifetime of battery, typ.<br />

Transponder<br />

5a<br />

Transmit frequency 2.4 GHz; Passive, frequency<br />

range: 2400 to 2483.5 MHz<br />

Range of transmitter 8m<br />

Transmission angle 93°<br />

Number of adjustable identifiers,<br />

max.<br />

Ambient conditions<br />

65 534; Not in °<br />

Operation (vertical installation) 0 °C to +50 °C<br />

Transport, storage -20 °C to +60 °C<br />

max. relative humidity 85 %<br />

IP65 at front Yes<br />

NEMA 4x / 12<br />

IP65 rear Yes<br />

Enclosure according to EN 60529 IP65<br />

Enclosure according to NEMA NEMA 4x, NEMA 12<br />

Certifications<br />

Functionality under WinCC<br />

flexible/WinCC (TIA Portal)<br />

Applications/options<br />

CE, cULus, C-TICK, NEMA 4x,<br />

NEMA 12<br />

Zones Yes<br />

Effective range<br />

Dimensions and weight<br />

Dimensions<br />

Yes<br />

External dimensions (W x H x D) in<br />

mm<br />

Weight<br />

172 x 90 x 38.5<br />

Weight 0.3 kg<br />

2/212<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Ordering data Order No.<br />

Transponder for<br />

Mobile Panels 277<br />

6AV6 671-5CM00-0AX1<br />

■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical<br />

specifications.<br />

45<br />

Transponder<br />

162<br />

172<br />

38.5<br />

90<br />

G_<strong>ST</strong><strong>80</strong>_XX_00298


■ Overview<br />

USB 2.0 flash drive<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Ordering data Order No.<br />

Operator panels<br />

HMI Accessories<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Memory media<br />

Multimedia card, 128 MB<br />

for Mobile Panel 177/277,<br />

OP 77B, TP/OP 177B,<br />

TP/OP 277 and MP 177/277/377<br />

A 6AV6 671-1CB00-0AX2<br />

SD Card, 512 MB<br />

for Mobile Panel 277, MP 177,<br />

MP 277, MP 377 and<br />

WinCC flexible 2008 SP1 and<br />

higher for OP 77, TP/OP 177/277,<br />

MP 177, with SD/MMC slot<br />

A 6AV6 671-8XB10-0AX1<br />

SD card, 2 GB<br />

for Comfort Panels<br />

A 6AV2 181-8XP00-0AX0<br />

SIMATIC I<strong>PC</strong> USB FlashDrive<br />

8 GB, USB 2.0, metal enclosure,<br />

bootable<br />

A 6ES7 648-0DC50-0AA0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

2/213<br />

2


2<br />

Operator panels<br />

HMI Accessories<br />

Converters/adapters<br />

■ Overview<br />

RS422 to RS232 converter, 9-pin<br />

90° angle adapter, 9-pin 1:1<br />

2/214<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Ordering data Order No.<br />

Converters/adapters<br />

RS422 to RS232 converter,<br />

9-pin<br />

pin - pin<br />

A 6AV6 671-8XE00-0AX0<br />

between Panel and non-<strong>Siemens</strong><br />

PLC with RS232 interface, for<br />

TP 177B, OP 177B, TP/OP 277-6,<br />

MP 277-8T/K, MP 277-10T/K<br />

RS422 / TTY converter<br />

9-pin / 15-pin for RS 422<br />

interface, pin-socket, 1<strong>80</strong> degree<br />

cable outlet for SIMATIC S5<br />

connection<br />

A 6AV6 671-8XJ00-0AX0<br />

90° angle adapter<br />

9-pin 1:1 pin (on panel) - socket,<br />

between TD/OP and plug-in cable<br />

6AV6 671-8XD00-0AX0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H


■ Overview<br />

The service packs listed below are available:<br />

PP7, PP17<br />

TD 17, OP 7, OP 17<br />

OP 73micro, OP 73, OP 77A, OP 77B<br />

TP 170micro, TP 070, TP 170A/B, OP 170B, TP/OP 270 6",<br />

TP/OP 277 6", MP 177 6" Touch, MP 270B 6" Touch<br />

TP 177micro, TP 177A, TP/OP 177B<br />

Mobile Panels 177/277<br />

Mobile Panels 277(F) IWLAN<br />

OP 270 10", MP 270B 10" Key<br />

TP 270 10", MP 270B 10" Touch, MP 370 12" Touch,<br />

C7-636 Touch, MP 370 15" Touch<br />

MP 277 8" Touch, MP 277 8" Key, MP 277 10" Touch,<br />

MP 277 10" Key<br />

MP 277 INOX 10" Touch<br />

MP 370 12" Key, MP 377 12" Key<br />

MP 377 INOX 15" Touch<br />

MP 377 12" Touch, MP 377 15" Touch, MP 377 19" Touch<br />

Industrial USB Hub 4<br />

The following are also available:<br />

24 V DC power supply connector set<br />

Touch pen with device for wall mounting<br />

Examples: Service pack for Mobile Panel<br />

Service pack for Mobile Panell<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Ordering data Order No.<br />

Operator panels<br />

HMI Accessories<br />

Service pack for PP7, PP17 6AV3 678-3XC30<br />

Consisting of:<br />

1 x PP7 gasket<br />

1 x PP17-I/PP17-II gasket<br />

5 x mounting clamps<br />

1 x 24 V PP7 plug-in terminal<br />

strip (2-pin)<br />

1 x 24 V PP17-I/PP17-II plug-in<br />

terminal strip (3-pin)<br />

Service pack for OP 73micro, 6AV6 671-1XA00-0AX0<br />

OP 73, OP 77A, OP 77B<br />

Consisting of:<br />

1 x OP 73micro, OP 73 mounting<br />

seal<br />

1 x OP 77A, OP 77B mounting<br />

seal<br />

4 x mounting clamps<br />

1 x 24 V plug-in terminal strip<br />

(2-pin)<br />

Service pack for TP 170micro, 6AV6 574-1AA00-4AX0<br />

TP070, TP 170A/B, OP 170B,<br />

TP/OP 270 6", TP/OP 277 6",<br />

MP 177 6" Touch,<br />

MP 270B 6" Touch<br />

Consisting of:<br />

1 x TP 170micro, TP070,<br />

TP 170A/B, TP 270 6", TP 277 6",<br />

MP 177 6" Touch mounting seal<br />

1 x OP 170B mounting seal<br />

1 x OP 270 6", OP 277 6"<br />

mounting seal<br />

1 x set of labeling strips for<br />

OP 170B<br />

1 x set of labeling strips for<br />

OP 270 6", OP 277 6"<br />

7 x mounting clamps<br />

1 x 24 V plug-in terminal strip<br />

(2-pin)<br />

Service pack for TP 177micro,<br />

TP 177A, TP 177B, OP 177B<br />

Consisting of:<br />

1 x TP 177micro, TP 177A,<br />

TP 177B mounting seal<br />

1 x OP 177B mounting seal<br />

7 x mounting clamps<br />

1 x 24 V plug-in terminal strip<br />

(2-pin)<br />

6AV6 671-2XA00-0AX0<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Service packs<br />

2/215<br />

2


2<br />

Operator panels<br />

HMI Accessories<br />

Service packs<br />

■ Ordering data Order No. Order No.<br />

Service pack for MP 277 8",<br />

E14 and higher 1) and<br />

MP 277 10" Touch,<br />

E14 and higher 1)<br />

2/216<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6AV6 671-3XA01-0AX1<br />

Consisting of:<br />

1 x MP 277 8" Touch mounting<br />

seal, E14 and higher 1)<br />

1 x MP 277 8" Key mounting<br />

seal, E14 and higher 1)<br />

1 x MP 277 10" Touch mounting<br />

seal, E14 and higher 1)<br />

10 x spring mounting clamps<br />

1 x 24 V plug-in terminal strip<br />

(2-pin)<br />

1 x Allen key<br />

Service pack for MP 277 INOX<br />

10" Touch<br />

Consisting of:<br />

1 x mounting seal<br />

10 x mounting clamps<br />

1 x 24 V plug-in terminal strip<br />

(2-pin)<br />

1 x Allen key<br />

A 6AV6 675-3AA00-0AX0<br />

Service pack for MP 370/MP 377<br />

12" Key<br />

Consisting of:<br />

2 x sets of labeling strips for OPs<br />

6 x mounting clamps<br />

1 x mounting bracket for<br />

CF memory card<br />

1 x mounting bracket for<br />

<strong>PC</strong> memory card<br />

1 x 24 V DC plug-in terminal strip<br />

(2-pin)<br />

1 x Allen key<br />

6AV6 574-1AA00-2BX0<br />

Service pack for MP 377<br />

12" Touch, MP 377 15" Touch,<br />

MP 377 19" Touch<br />

A 6AV6 671-4XA00-0AX0<br />

Consisting of:<br />

1 x MP 377 12" Touch mounting<br />

seal<br />

1 x MP 377 12" Key mounting<br />

seal<br />

1 x MP 377 15" Touch mounting<br />

seal<br />

1 x MP 377 19" Touch mounting<br />

seal<br />

18 x mounting clamps<br />

1 x 24 V DC plug-in terminal strip<br />

(2-pin)<br />

1 x Allen key<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

1) E14 = Product version 14<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Service pack for<br />

Mobile Panels 177/277<br />

Consisting of:<br />

Blanking plugs for cable duct<br />

2 x cable glands for connectivity<br />

box<br />

1 set of screws for connectivity<br />

box cover<br />

2 x terminal box (12-pin)<br />

1 x terminal box (3-pin)<br />

1 x blanking cap for connectivity<br />

box<br />

6AV6 574-1AA04-4AA0<br />

Service pack for<br />

Mobile Panels 277(F) IWLAN<br />

A 6AV6 671-5CA00-0AX2<br />

Consisting of:<br />

1 x battery slot cover (device)<br />

1 x left/right cover (charging<br />

station)<br />

1 x 24 V DC power supply<br />

mating connector (charging<br />

station)<br />

1 x spare key (charging station)<br />

Service pack for Industrial USB<br />

Hub 4<br />

Consisting of:<br />

1 x mounting seal<br />

1 x rear metal frame (for<br />

achieving IP65 with mounting<br />

plates that are less than 3 mm<br />

thick)<br />

5 x mounting clamps<br />

1 x 24 V plug-in terminal strip<br />

(2-pin)<br />

6AV6 671-3EA01-0AX0<br />

Power supply connector set<br />

Consisting of:<br />

10 x 24 V DC power supply<br />

connectors (2-pin)<br />

A 6AV6 671-8XA00-0AX0<br />

Touch pen with device for wall<br />

mounting<br />

Touch pen suitable for all touch<br />

panels and touch displays, incl.<br />

wall holder for screwing in place<br />

6AV7 672-1JB00-0AA0


© <strong>Siemens</strong> AG <strong>2011</strong><br />

Operator panels<br />

HMI Accessories<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Protective covers<br />

■ Overview<br />

■ Ordering data Order No.<br />

Protective covers for<br />

TP 070, TP 170micro,<br />

TP 177micro,<br />

TP 170A/B, TP 177A/B,<br />

TP 270 6", TP 277 6"<br />

MP 177 6" Touch,<br />

MP 270 6" Touch<br />

(2 sets per pack)<br />

Consisting of:<br />

2 cover frames<br />

2 base frames<br />

2 protective covers, molded<br />

(for TP 070, TP 170micro,<br />

TP 170A/B)<br />

2 protective covers smooth<br />

(for TP 177micro, TP 177A/B,<br />

TP 270 6“, MP 177 6“ Touch,<br />

MP 270 6“ Touch)<br />

6AV6 574-1AE00-4AX0<br />

Protective covers for OP 77A/B 6AV6 671-1AJ00-0AX0<br />

Protective covers with IP65 degree of protection provide<br />

(2 sets per pack)<br />

complete frontal protection of the panel against dirt and<br />

Consisting of:<br />

scratches; the protective covers can be kept clean using high- 2 cover frames<br />

pressure cleaning equipment. Own frame designs can be<br />

created and printed out at low cost (ready-made Word templates<br />

can be downloaded) between panel and protective cover.<br />

2 base frames<br />

2 protective covers<br />

Protective covers for OP 177B 6AV6 671-2DJ00-0AX0<br />

For simple display protection, adhesive protective foils are<br />

available.<br />

The following protective covers are available:<br />

(2 sets per pack)<br />

Consisting of:<br />

2 cover frames<br />

TP 070, TP 170micro, TP 177micro, TP 170A/B, TP 177A/B,<br />

TP 270 6“, TP 277 6", MP 177 6“ Touch, MP 270B 6“ Touch<br />

2 base frames<br />

2 protective covers<br />

OP 77 A/B<br />

Protective covers for<br />

6AV6 671-3CK01-0AX0<br />

OP 177B<br />

MP 277 8" Touch<br />

MP 277 8" Touch<br />

(2 sets per pack) for<br />

MP 277 10" Touch, Thin Client 10"<br />

MP 277 8" Touch<br />

6AV6 643-0CB01-1AX1 up to<br />

E05<br />

1) E05 = Product version 05<br />

2) E06 = Product version 06<br />

3) E03 = Product version 03<br />

1) and<br />

6AV6 643-0CB01-1AX5 E05 1)<br />

and higher<br />

Consisting of:<br />

2 cover frames<br />

2 base frames<br />

2 protective covers<br />

Protective covers for<br />

MP 277 10" Touch,<br />

Thin Client 10"<br />

(2 sets per pack) for<br />

MP 277 10" Touch<br />

6AV6 643-0CD01-1AX1 up to<br />

E06<br />

6AV6 671-3CK00-0AX0<br />

2) and<br />

6AV6 643-0CD01-1AX5 E06 2)<br />

and higher, as well as<br />

Thin Client 10" for<br />

6AV6 646-0AA21-2AX0 up to<br />

E03 3)<br />

Consisting of:<br />

2 cover frames<br />

2 base frames<br />

2 protective covers<br />

2/217<br />

2


2<br />

Operator panels<br />

HMI Accessories<br />

Cover foils<br />

■ Overview<br />

Cover foils for:<br />

Basic Panels 4" to 15"<br />

Comfort Panels touch devices (TP and KTP)<br />

TD 200C<br />

TD 400C<br />

TP 070, TP 170micro, TP 170A/B, C7-635 Touch<br />

TP 177micro, TP 177A/B, OP 177B<br />

KTP400, TP 177B 4"<br />

Mobile Panel 177<br />

Mobile Panel 277 8", Mobile Panel 277 10"<br />

TP 270 6", TP 277 6", MP 177 6" Touch,<br />

MP 270B 6" Touch, C7-635 Touch<br />

TP 270 10", MP 270B 10", MP 370 12" Touch,<br />

MP 377 12" Touch, C7-636 Touch<br />

MP 277 8" and 10", Thin Client 10"<br />

MP 370 15" Touch, MP 377 15" Touch, Thin Client 15"<br />

MP 377 19" Touch<br />

2/218<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Protective pockets for:<br />

Labeling strips for Mobile Panel 170 and Mobile Panel 177<br />

Key labeling strips for:<br />

Mobile Panel 277<br />

MP 370 12" Key / MP 377 12" Key<br />

Protective foils serve to protect the display from dirt and<br />

scratching during use. The labeling strips, blank foils, and<br />

protective foils should be printed at a printing works. Readymade<br />

Word templates can be used to create labeling strips for<br />

SIMATIC HMI touch devices.<br />

For complete protection of the front side, protective covers are<br />

available.


■ Ordering data Order No. Order No.<br />

Cover foils for<br />

HMI KTP400 Comfort<br />

(pack of 10 each)<br />

6AV2 124-6DJ00-0AX0<br />

Cover foils for<br />

HMI TP700 Comfort<br />

(pack of 10 each)<br />

6AV2 124-6GJ00-0AX0<br />

Cover foils for<br />

HMI TP900 Comfort<br />

(pack of 10 each)<br />

6AV2 124-6JJ00-0AX0<br />

Cover foils for<br />

HMI TP1200 Comfort<br />

(pack of 10 each)<br />

6AV2 124-6MJ00-0AX0<br />

Blank foils for TD 200C<br />

for customer-specific keyboard<br />

layouts; 3 perforated films per<br />

sheet (10 sheets per pack)<br />

A 6ES7 272-1AF00-7AA0<br />

Blank foils for TD 400C<br />

for customer-specific keyboard<br />

layouts; 3 perforated films per<br />

sheet (10 sheets per pack)<br />

6AV6 671-0AP00-0AX0<br />

Cover foils for TP 070,<br />

TP 170micro, TP 170A/B,<br />

C7-635 Touch<br />

6AV6 574-1AD00-4AX0<br />

(pack of 10 each)<br />

Cover foils for<br />

TP 177micro, TP 177A, TP 177B<br />

Cover foils for HMI KTP400<br />

Basic, TP 177B 4"<br />

(pack of 10 each)<br />

Cover foils for<br />

Mobile Panel 177<br />

(pack of 10 each)<br />

Cover foils for<br />

Mobile Panel 277 8"<br />

Tough film to protect the touch<br />

display from dirt and scratches<br />

(set of 2 per pack)<br />

Cover foils for<br />

Mobile Panel 277 10"<br />

Tough film to protect from dirt and<br />

scratches (set of 10 per pack)<br />

Cover foils for TP 270 6",<br />

TP 277 6", MP 177 6" Touch,<br />

MP270B6"Touch,<br />

C7-635 Touch,<br />

HMI KTP600 Basic<br />

(pack of 10 each)<br />

6AV6 671-2XC00-0AX0<br />

6AV6 671-2EC00-0AX0<br />

6AV6 574-1AD04-4AA0<br />

6AV6 671-5BC00-0AX0<br />

6AV6 645-7AB15-0AS0<br />

6AV6 574-1AD00-4DX0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Cover foils for TP 270 10",<br />

MP 270B 10",<br />

MP 370 12" Touch, MP 377 12"<br />

Touch, C7-636 Touch<br />

(pack of 10 each)<br />

Cover foils for MP 277 8"<br />

MP 277 8" Touch/Key up to<br />

E14 1)<br />

(pack of 10 each)<br />

Cover foils for MP 277 8"<br />

(6AV6 643-0CB01-1AX1),<br />

ES15 or higher<br />

(ES = product version)<br />

(pack of 10 each)<br />

Cover foils for MP 277 10"<br />

Touch, Thin Client 10"<br />

for 6AV6 646-0AA21-2AX0,<br />

MP 277 10" Touch up to E14 1)<br />

(pack of 10 each)<br />

Cover foils for MP 277<br />

10" Touch, MP 377 12" and<br />

Thin Client 10" Touch<br />

(6AV6 643-0CD01-1AX1),<br />

ES15 2) or higher,<br />

HMI KTP1000 Basic<br />

(pack of 10 each)<br />

Cover foils for<br />

MP 370 15” Touch, MP 377<br />

15" Touch, Thin Client 15",<br />

HMI TP1500 Basic<br />

(pack of 10 each)<br />

Cover foils for MP 377,<br />

19" Touch<br />

(pack of 10 each)<br />

Protective pockets for labeling<br />

strips for Mobile Panel 170 and<br />

Mobile Panel 177<br />

(5 units per pack) for labeling<br />

strips for Mobile Panel 177 and<br />

277<br />

Key labeling strips for<br />

Mobile Panel 277<br />

Packet for labeling 6 devices<br />

(2 sheets per pack), incl. spare<br />

stickers for cover caps<br />

Key labeling strips MP 370<br />

12" Key/MP 377 12" Key<br />

For function keys,<br />

(2 sheets per pack) (plastic)<br />

1) E14 = Product version 14<br />

2) E15 = product version 15<br />

Operator panels<br />

HMI Accessories<br />

6AV6 574-1AD00-4CX0<br />

6AV6 671-3CC00-0AX0<br />

6AV6 671-3CC00-0AX5<br />

6AV6 671-3DC00-0AX0<br />

6AV6 671-3DC00-0AX5<br />

6AV6 574-1AD00-4EX0<br />

6AV7 672-1CE00-0AA0<br />

6AV6 574-1AB04-4AA0<br />

6AV6 671-5BF00-0AX0<br />

6AV6 574-1AB00-2BA0<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Cover foils<br />

2/219<br />

2


2<br />

Operator panels<br />

HMI Accessories<br />

Fixing elements<br />

■ Overview<br />

■ Ordering data<br />

Clamping frame<br />

Order No.<br />

for MP 277 8" Touch 6AV6 671-3CS00-0AX0<br />

for MP 277 8" Key 6AV6 671-3CS01-0AX0<br />

for 10"/12" Touch<br />

can be used for:<br />

KTP1000, MP 277 10" Touch,<br />

MP 377 12" Touch,<br />

Thin Client 10"<br />

Clamping fixture<br />

6AV6 671-8XS00-0AX0<br />

Spring-type clamping fixture<br />

for KTP400 Comfort, KP400<br />

Comfort and TP/OP 77A/B,<br />

suitable for plate thicknesses up<br />

to 6 mm.<br />

20 spring clamps per packaging<br />

unit<br />

6AV6 671-8XK00-0AX2<br />

Spring-type clamping fixture 6AV6 671-8XK00-0AX1<br />

The clamping frames enable compliance with degrees of<br />

protection IP65, NEMA4x and NEMA12 (indoor only) if the<br />

thickness of the mounting plate is less than the minimum plate<br />

thickness specified in the manual. The clamping frame has been<br />

specially developed for plate thicknesses of less than 2 mm.<br />

For MP 177, TP/OP/MP 277, MP<br />

377 12" Touch, MP 377 15" Touch,<br />

Thin Client and all Basic Panels;<br />

suitable for sheet thickness of<br />

1 mm to 4 mm.<br />

20 spring clamps per packaging<br />

Aluminum and plastic spring-type clamping fixtures are<br />

unit<br />

available for attaching the panel.<br />

Aluminum clamps<br />

For MP 177, TP/OP/MP 277,<br />

MP 377, Thin Client and all Basic<br />

Panels; suitable for sheet<br />

thickness of 4 mm to 6 mm.<br />

20 aluminum clamps per<br />

packaging unit<br />

6AV6 671-8XK00-0AX0<br />

For the Thin Client 10" Touch, the clamping frame is needed for<br />

plate thicknesses of less than 2 mm, for both IP54 and IP65<br />

degrees of protection.<br />

The clamping frames are available for the following products:<br />

KTP1000 Basic color<br />

SIMATIC MP 277 8" Touch<br />

SIMATIC MP 277 8" Key<br />

SIMATIC MP 277 10" Touch<br />

SIMATIC MP 377 12" Touch<br />

SIMATIC Thin Client 10" Touch<br />

2/220<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Overview<br />

Print functions of SIMATIC HMI Panels<br />

Hardcopy Print log<br />

Functionality possible<br />

1) Variable, messages, recipes<br />

2) Included in log<br />

Note:<br />

OP 73micro, OP 73, OP 77A, TP 177micro, TP 177A do not<br />

include a printer interface<br />

Approved printers, sources of supply and printer settings<br />

You will find an overview of approved printers, sources of supply<br />

and printer settings on the Internet at:<br />

http://support.automation.siemens.com/WW/view/en/11376409<br />

1) Alarm Fault<br />

logging message<br />

buffer<br />

Comfort Panels • • •<br />

OP 77B • • •<br />

TP/OP 177B • • •<br />

TP/OP 277 • • •<br />

MP 177 • • •<br />

MP 277 • • •<br />

MP 377 • • •<br />

Event<br />

message<br />

buffer<br />

Operator panels<br />

Printers<br />

Recommended printers for panels and<br />

Multi Panels<br />

Event<br />

record<br />

with filter<br />

Print data<br />

record<br />

Print all<br />

data<br />

records<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Header/<br />

footer<br />

2) 2) 2) 2) 2) 2)<br />

2) 2) 2) 2) 2) 2)<br />

2) 2) 2) 2) 2) 2)<br />

2) 2) 2) 2) 2) 2)<br />

2) 2) 2) 2) 2) 2)<br />

2) 2) 2) 2) 2) 2)<br />

2) 2) 2) 2) 2) 2)<br />

2/221<br />

2


2<br />

Notes<br />

2/222<br />

Operator panels<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI devices<br />

for special requirements<br />

3/2 Introduction<br />

3/3 Fully enclosed HMI devices<br />

3/5 SIMATIC MP 377 PRO<br />

3/8 SIMATIC Thin Client PRO<br />

3/10 SIMATIC Flat Panel PRO<br />

3/12 SIMATIC HMI I<strong>PC</strong>477C PRO<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

3<br />

3/17 Accessories for fully enclosed<br />

HMI devices<br />

3/17 Adapter sets<br />

3/18 Extension units<br />

3/19 IP65 keyboards<br />

3/20 Single-port USB interface<br />

3/21 Devices with stainless steel front<br />

3/22 SIMATIC TP 177B INOX<br />

3/27 SIMATIC MP 277 INOX<br />

3/33 SIMATIC MP 377 INOX<br />

3/38 SIMATIC Panel <strong>PC</strong> 677B INOX<br />

3/45 SIMATIC HMI I<strong>PC</strong>677C INOX<br />

3/51 HMI devices for hazardous areas<br />

3/53 SIMATIC HMI Panel <strong>PC</strong> Ex<br />

3/56 SIMATIC HMI Thin Client Ex


3<br />

HMI devices for special requirements<br />

Introduction<br />

■ Overview<br />

Fully enclosed HMI devices<br />

The fully enclosed SIMATIC HMI devices (MP 377 PRO, Thin<br />

Client PRO, Flat Panel PRO, and HMI I<strong>PC</strong>477C PRO) are<br />

specially designed for mounting on a support arm/stand. Thanks<br />

to their extremely rugged design, the devices are ideal for industrial<br />

applications in harsh environments.<br />

Devices with stainless steel front<br />

For special requirements, HMI devices with stainless steel fronts<br />

(TP 177B INOX, MP 277 INOX, MP 377 INOX, Panel <strong>PC</strong> 677B<br />

INOX and HMI I<strong>PC</strong>677C INOX) are offered for use in the food &<br />

beverage industry.<br />

HMI devices for hazardous areas<br />

The SIMATIC HMI Ex devices (HMI Panel <strong>PC</strong> Ex and HMI Thin<br />

Client Ex) are intrinsically safe Panel <strong>PC</strong>s and Thin Clients that<br />

have been specially developed for hazardous areas "Zone 1"<br />

and "Zone 2". Further SIMATIC HMI devices are also available for<br />

the hazardous area "Zone 2" and can be found in the chapter<br />

"Operator panels".<br />

3/2<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Overview<br />

The new SIMATIC fully enclosed HMI devices have been<br />

specially designed for mounting on a support arm/foot. Thanks<br />

to their extremely rugged design, the devices are ideal for industrial<br />

applications even in harsh environments.<br />

The following are available as SIMATIC fully enclosed<br />

HMI devices:<br />

SIMATIC MP 377 PRO 15" Touch<br />

SIMATIC Thin Client PRO 15" Touch<br />

SIMATIC Flat Panel PRO 15"/19" Touch<br />

SIMATIC HMI I<strong>PC</strong>477C PRO 15"/19" Touch<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI devices for special requirements<br />

Fully enclosed HMI devices<br />

■ Benefits<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Introduction<br />

For direct mounting on supporting arm/foot<br />

Fully enclosed with IP65, enclosure type 4X<br />

Low depth and weight of the device<br />

Connection of the device optionally from above or below<br />

Total flexibility in the selection of supporting arm components<br />

thanks to direct connection to well-known supporting arm<br />

manufacturers<br />

Supports the globally established VESA 75/VESA 100<br />

standard<br />

Service-friendly – device does not have to be removed from<br />

the supporting arm for servicing or replacing memory cards<br />

Rugged and extremely compact aluminum enclosure<br />

Functionally 100%-compatible with the field-proven built-in<br />

units<br />

Standard connecting cables can be used<br />

■ Application<br />

The SIMATIC HMI PRO (PRO = protected) devices have been<br />

designed for mounting on a support arm/foot. Thanks to their<br />

rugged aluminum enclosures, the SIMATIC HMI PRO devices<br />

have all-round IP65 protection and are also suitable for use in<br />

harsh environments. The separation of HMI and control cabinet<br />

allows flexible design concepts.<br />

The new SIMATIC HMI PRO devices are used wherever the HMI<br />

device cannot be installed direct in the control cabinet due to<br />

restricted space, or whenever an operator unit is required direct<br />

at the machine.<br />

The devices stand out not only due to their compact and<br />

appealing industrial design, but also due to their refined<br />

mechanical features. This enables the device to be connected<br />

to the support arm system optionally from above or below.<br />

A host of support arm systems from well-known manufacturers<br />

are supported here. The SIMATIC HMI PRO devices are also<br />

suitable for connection to systems in accordance with VESA 75<br />

and VESA 100.<br />

With the extension units, the range of possible on-site operations<br />

can be extended. The extension units can be mounted on the<br />

right and/or left side of the SIMATIC HMI PRO device and can be<br />

equipped individually with, for example, illuminated<br />

pushbuttons, emergency stop button, RFID reader, etc.<br />

The SIMATIC HMI PRO devices are extremely light-weight at<br />

between 6.5 kg and 10 kg (depending on the device) and can<br />

thus be installed quickly and easily.<br />

All the devices are fan-free, and only standard connecting<br />

cables are used.<br />

3/3<br />

3


3<br />

HMI devices for special requirements<br />

Fully enclosed HMI devices<br />

Introduction<br />

■ Design<br />

General<br />

Degree of protection IP65 (front and rear)<br />

Degree of protection Enclosure Type 4X (front and rear)<br />

Die-cast aluminum housing<br />

Compact design with low mounting depth<br />

15.1" TFT color display, 1024 x 768 pixels (XGA)<br />

19" TFT color display, 12<strong>80</strong> x 1024 pixels (SXGA)<br />

Resistive analog touch screen<br />

Terminals for 24 V DC power supply<br />

Flat Panel PRO/HMI I<strong>PC</strong>477C PRO<br />

Also available as 19" TFT color display,<br />

12<strong>80</strong> x 1024 pixels (XGA)<br />

Additional 230 V AC power supply (only Flat Panel PRO)<br />

Accessories<br />

For fully enclosed HMI devices there are available:<br />

adapter sets<br />

extension units<br />

IP65 keyboards and<br />

a 1-port USB interface.<br />

■ Function<br />

SIMATIC MP 377 PRO:<br />

Multi Panel for operator control and monitoring of machines<br />

and plants<br />

SIMATIC Thin Client PRO:<br />

Operator panel for terminal and web client applications<br />

SIMATIC Flat Panel PRO:<br />

Industrial monitor with touch functionality, can be located up<br />

to 30 m from the operator control unit (as with Flat Panel<br />

Extended)<br />

SIMATIC HMI I<strong>PC</strong>477C PRO:<br />

Compact, rugged and maintenance-free embedded I<strong>PC</strong><br />

3/4<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Integration<br />

Mechanical integration<br />

The SIMATIC HMI PRO devices can be mounted direct on the<br />

support arm head of the desired support arm system using the<br />

basic adapter supplied and an adapter plate to be ordered<br />

separately. The basic adapter is attached to the device<br />

optionally from below or from above. The connecting cables are<br />

run through the support arm.<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/ip65-hmi-devices<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.


■ Overview<br />

SIMATIC MP 377 PRO 15"<br />

■ Application<br />

The SIMATIC Multi Panel 377 PRO can be used wherever<br />

operation and monitoring of machines and plants are required.<br />

As an especially high-performance device, the Multi Panel is<br />

suitable for demanding HMI tasks. However, in addition to visualization,<br />

the devices can also handle other automation tasks such<br />

as providing the platform for a software PLC.<br />

The SIMATIC Thin Client PRO is ideally suitable as a second,<br />

low-cost operator console on a MP 377 PRO.<br />

■ Integration<br />

Integrated interfaces SIMATIC MP 377 PRO:<br />

2 x Ethernet<br />

The integrated Ethernet interfaces are used for IT<br />

communication and for data exchange with programmable<br />

controllers such as SIMATIC S7<br />

PROFIBUS/MPI (RS 485/ RS 422)<br />

The floating PROFIBUS interface (12 Mbit/s) is used for<br />

connecting distributed field devices or for connecting to<br />

SIMATIC S7<br />

Further interfaces<br />

Two USB 2.0 interfaces (Universal Serial Bus), one<br />

CompactFlash Card interface, and one SD/MMC slot are<br />

available for connecting further I/O devices.<br />

■ Technical specifications<br />

6AV6 644-2AB01-2AX0<br />

Display<br />

Size 15" (304.1 mm x 228.1 mm)<br />

Display type TFT, 65536 Farben<br />

Resolution (pixels)<br />

Resolution (WxH in pixel) 1024 x 768<br />

Backlighting<br />

MTBF backlighting (at 25 °C) about 50,000 hours<br />

Control elements<br />

Control elements Touch screen<br />

Connection for mouse/keyboard/ USB / USB / USB<br />

barcode reader<br />

Keyboard<br />

Numeric/alphabetical input Yes / Yes<br />

Touch operation<br />

Touch screen analog, resistive<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI devices for special requirements<br />

Fully enclosed HMI devices<br />

SIMATIC MP 377 PRO<br />

6AV6 644-2AB01-2AX0<br />

Supply voltage<br />

Input voltage<br />

permissible range +20.4 V to +28.8 V DC<br />

Supply voltage 24 V DC<br />

Input current<br />

Rated current 1.8 A<br />

Memory<br />

Type Flash / RAM<br />

Type of output<br />

Acoustics Sound signal<br />

Time of day<br />

Clock<br />

Type Hardware clock, battery backup,<br />

synchronizable<br />

Interfaces<br />

Interfaces 1 x RS422, 1 x RS485,<br />

2 x Ethernet (RJ45)<br />

USB port 2 x USB<br />

CF card slot 1 x CF card slot<br />

Multi Media Card slot 1 x Multi Media Card slot<br />

Industrial Ethernet<br />

Industrial Ethernet interface 2 x Ethernet (RJ45)<br />

Protocols<br />

Protocols (terminal link)<br />

Sm@rtAccess Yes<br />

Ambient conditions<br />

Operating temperature<br />

Operation (vertical installation) 0 °C to +45 °C<br />

Operation (max. tilt angle) 0 °C to +45 °C<br />

Storage/transport temperature<br />

Transport, storage -20 °C to +60 °C<br />

Relative humidity<br />

max. relative humidity 85 %<br />

Mounting position vertical<br />

maximum permissible angle of incli- +/- 45 °<br />

nation without external ventilation<br />

Degree and class of protection<br />

Front IP65, NEMA 4 (when installed)<br />

Rear IP65<br />

Standards, approvals, certificates<br />

Certifications CE, cULus, C-TICK, NEMA 4<br />

Operating systems<br />

Operating system Windows CE<br />

Configuration<br />

Configuration software<br />

Configuration tool see "Configuration overview" from<br />

page 2/3<br />

Functionality under<br />

WinCC flexible<br />

Applications/options see chapter 4: HMI software/<br />

SIMATIC WinCC flexible options<br />

and SIMATIC WinCC options<br />

(TIA portal)<br />

Number of Visual Basic Scripts 100<br />

Task planner Yes<br />

Help system Yes<br />

Status/control with SIMATIC S7<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

3/5<br />

3


3<br />

HMI devices for special requirements<br />

Fully enclosed HMI devices<br />

SIMATIC MP 377 PRO<br />

■ Technical specifications (continued)<br />

With alarm logging system<br />

(incl. buffer and acknowledgment)<br />

Number of messages 4000<br />

Bit messages Yes<br />

Analog messages Yes<br />

Message buffer Ring buffer (n x 1024 entries),<br />

retentive, maintenance-free<br />

Recipes<br />

Recipes 500<br />

Data records per recipe 1000<br />

Entries per data record 1000<br />

Recipe memory 128 KB integrated Flash,<br />

expandable<br />

Number of process images<br />

Process images 500<br />

Variables 2048<br />

Limit values Yes<br />

Multiplexing Yes<br />

Image elements<br />

Text objects 30,000 text elements<br />

Graphics object Bit maps, icons, vector graphics<br />

dynamic objects Diagrams, bar graphs, sliders,<br />

analog display, invisible buttons<br />

Lists<br />

Text lists 500<br />

Graphics list 500<br />

Libraries Yes<br />

Archiving<br />

Number of archives per project 50<br />

Number of measuring points per 50<br />

project<br />

Number of entries per archive 50 000<br />

Archiving types Sequence archive, short-term<br />

archive, alarm log, process value<br />

archive<br />

Memory location CF card, SD/MMC card, Ethernet<br />

Data storage format CSV file, readable, e.g. with<br />

MS Excel, MS Access<br />

external evaluation Can be read, e. g., in MS Excel,<br />

MS Access, etc.<br />

Size of archive Depending on free memory on<br />

ext. card/stick or on free hard disk<br />

memory via network drive<br />

Online evaluation Using trend curves<br />

Security<br />

Number of user groups 50<br />

Passwords exportable Yes<br />

Number of user rights 32<br />

Data carrier support<br />

CF card Yes<br />

Multimedia Card Yes<br />

Recording<br />

Recording/Printing Alarms, report (shift report),<br />

color print, hardcopy<br />

Printer driver ESC/P2, <strong>PC</strong>L3/<strong>PC</strong>L6<br />

Fonts<br />

Keyboard fonts US American (English)<br />

Languages<br />

Configuration languages D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified", DK, FIN, GR, J,<br />

KP / ROK, NL, N, PL, P, RUS, S,<br />

CZ / SK, TR, H<br />

Character sets Tahoma, Arial, Courier New,<br />

symbol languages, 4 additional<br />

character sets can be loaded,<br />

all freely scalable<br />

3/6<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6AV6 644-2AB01-2AX0<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV6 644-2AB01-2AX0<br />

Transfer (upload/download)<br />

Transfer of configuration MPI/PROFIBUS DP, serial, USB,<br />

Ethernet, by means of external<br />

storage medium, automatic<br />

transfer recognition<br />

Process coupling<br />

Connection to controller see "System interfaces" from<br />

page 2/179<br />

Expandability/openness<br />

Open Platform Program Yes<br />

I/O<br />

I/O devices Printer, card reader, barcode<br />

reader<br />

Dimensions and weight<br />

Dimensions<br />

Front of enclosure (W x H) 400 mm x 310 mm<br />

Mounting cutout/device depth<br />

(W x H)<br />

Weight<br />

Weight 7.25 kg<br />

■ Ordering data Order No.<br />

400 mm x 310 mm/98.5 mm<br />

device depth<br />

SIMATIC MP 377 PRO 15"<br />

Touch<br />

15" color TFT display,<br />

12 MB configuration memory,<br />

configurable from<br />

WinCC flexible 2007<br />

E 6AV6 644-2AB01-2AX0<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

Note:<br />

An adapter plate is necessary for installation,<br />

see "Fully protected HMI devices."


■ Dimensional drawings<br />

All specifications in mm.<br />

Panel cutout see technical specifications.<br />

400<br />

SIMATIC MP 377 PRO 15" Touch<br />

310<br />

67.85<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

98.5<br />

HMI devices for special requirements<br />

Fully enclosed HMI devices<br />

G_<strong>ST</strong><strong>80</strong>_XX_00351<br />

SIMATIC MP 377 PRO<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/ip65-hmi-devices<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

3/7<br />

3


3<br />

HMI devices for special requirements<br />

Fully enclosed HMI devices<br />

SIMATIC Thin Client PRO<br />

■ Overview<br />

SIMATIC Thin Client PRO 15"<br />

■ Application<br />

The SIMATIC Thin Client PRO is ideal as a second, low-cost<br />

operator console for terminal and client applications.<br />

■ Design<br />

Thin Client PRO 15" Touch<br />

All-round IP65 protection<br />

Enclosure type 4x/type 12 (indoor use only)<br />

For mounting on support arm/foot<br />

15" touch display<br />

Rugged die-cast aluminum enclosure<br />

Adaptation of the device optionally from above or below<br />

Direct connection to support arm systems of well-known<br />

manufacturers (Rittal, Bernstein, Rose, Haseke, and Rolec)<br />

Supports the globally established VESA 75/<br />

VESA 100 standard<br />

■ Integration<br />

Integrated interfaces SIMATIC Thin Client PRO:<br />

1 x Ethernet interface<br />

For operating on PROFINET and Ethernet networks<br />

1 x USB interface<br />

For connecting mouse and keyboard as external input<br />

devices<br />

■ Technical specifications<br />

6AV6 646-2AB21-2AX0<br />

Product type designation PRO 15" Touch<br />

Display<br />

Size 15.1"<br />

Display type TFT, 65536 Farben<br />

Resolution (pixels)<br />

Resolution (WxH in pixel) 1024 x 768<br />

Backlighting<br />

MTBF backlighting (at 25 °C) about 50,000 hours<br />

3/8<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV6 646-2AB21-2AX0<br />

Control elements<br />

Control elements Touch screen<br />

Connection for mouse/keyboard/ USB / USB<br />

barcode reader<br />

Touch operation<br />

Touch screen analog, resistive<br />

Supply voltage<br />

Input voltage<br />

permissible range +19.2 V to +28.8 V DC<br />

Supply voltage 24 V DC<br />

Processor<br />

Processor ARM, 266 MHz<br />

Memory<br />

Type Flash / RAM<br />

Usable memory for user data No info<br />

Interfaces<br />

Interfaces 1 x Ethernet (RJ45)<br />

USB port 1 x USB<br />

Industrial Ethernet<br />

Industrial Ethernet interface 1 x Ethernet (RJ45)<br />

Protocols<br />

WEB characteristics<br />

HTTP Yes<br />

HTML Yes<br />

CSS Yes<br />

Protocols (terminal link)<br />

Sm@rtAccess Yes<br />

RDP Yes<br />

EMC<br />

Emission of radio interference acc.<br />

to EN 55 011<br />

Emission of radio interferences<br />

acc. to EN 55 011 (limit class A)<br />

Yes; EN 61000-6-4, interference<br />

emission: Intended for use in<br />

industrial areas.<br />

Ambient conditions<br />

Operating temperature<br />

Operation (vertical installation) 0 °C to +45 °C<br />

Storage/transport temperature<br />

Transport, storage -20 °C to +60 °C<br />

Relative humidity<br />

max. relative humidity 85 %; (Storage)<br />

maximum permissible angle of incli- +/- 45 °<br />

nation without external ventilation<br />

Degree and class of protection<br />

Front IP65, NEMA 4x, NEMA 12<br />

(when installed)<br />

Rear IP65<br />

Standards, approvals, certificates<br />

Certifications CE, cULus, C-TICK, NEMA 4x<br />

(Enclosure Type 4X, Type 12),<br />

NEMA 12<br />

Dimensions and weight<br />

Dimensions<br />

Front of enclosure (W x H) 400 mm x 310 mm<br />

Weight<br />

Weight 6.5 kg


■ Ordering data Order No.<br />

SIMATIC Thin Client PRO<br />

15" Touch<br />

Starter packages<br />

SIMATIC Thin Client with<br />

Sm@rtAccess<br />

D 6AV6 646-2AB21-2AX0<br />

Touch device 15" PRO with<br />

Sm@rtAccess license (panels)<br />

D 6AV6 653-6CA01-2AA0<br />

Touch device 15" PRO with<br />

Sm@rtAccess license for<br />

WinCC flexible 2008 Runtime<br />

D 6AV6 653-6FA01-2AA0<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

Note:<br />

An adapter plate is necessary for installation,<br />

see "Fully protected HMI devices."<br />

■ Dimensional drawings<br />

All specifications in mm.<br />

Panel cutout see technical specifications.<br />

400<br />

SIMATIC Thin Client PRO 15" Touch<br />

310<br />

67.85<br />

90.85<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI devices for special requirements<br />

Fully enclosed HMI devices<br />

G_<strong>ST</strong><strong>80</strong>_XX_00350<br />

SIMATIC Thin Client PRO<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/ip65-hmi-devices<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

3/9<br />

3


3<br />

HMI devices for special requirements<br />

Fully enclosed HMI devices<br />

SIMATIC Flat Panel PRO<br />

■ Overview<br />

■ Technical specifications<br />

Flat Panel<br />

Supply voltage<br />

PRO 15" PRO 19"<br />

Supply voltage 24 V DC and 24 V DC and<br />

230 V AC 230 V AC<br />

combined combined<br />

permissible frequency range 47 to 63 Hz 47 to 63 Hz<br />

Power consumption, max.<br />

General features<br />

35 VA 35 VA<br />

Can be separate from the computer<br />

Display<br />

up to 30 m up to 30 m<br />

On-screen display (OSD)<br />

configuration<br />

Yes Yes<br />

Display version 15" TFT 19" TFT<br />

visible area (H x W) in mm 304 x 228 376 x 301<br />

Viewing angle 140° x 120° 140° x 120°<br />

SIMATIC Flat Panel Monitor PRO 19"<br />

Pixel pitch<br />

(min)<br />

0.297 mm x<br />

(min)<br />

0.297 mm x<br />

0.297 mm 0.297 mm<br />

Resolution (W x H in pixels) 1024 x 768 12<strong>80</strong> x 1024<br />

Refresh rate 60 to 75 Hz 60 to 75 Hz<br />

Line frequency 46.7 - <strong>80</strong> kHz 46.7 - <strong>80</strong> kHz<br />

Brightness/contrast > 260 cd/m<br />

SIMATIC Flat Panel Monitor PRO 15" with expansion unit (rear view)<br />

SIMATIC Flat Panel monitors are highly suitable as remote<br />

operator stations for Rack/Box I<strong>PC</strong>s.<br />

They can be mounted directly on a supporting bracket up to<br />

30 m away from the I<strong>PC</strong>. Alternatively, Flat Panel monitors can be<br />

used as a 2nd operator control unit on a Panel <strong>PC</strong> such as the<br />

HMI I<strong>PC</strong>477C.<br />

2 / > 300 cd/m<br />

350:1<br />

2 /<br />

300:1<br />

Number of colors 16.7 million 16.7 million<br />

MTBF of backlit display (at 25 °C,<br />

24 hours continuous operation)<br />

Type of operation<br />

50,000 h 50,000 h<br />

Touch screen analoganalogresistiveresistive Connection for keyboard/mouse/<br />

barcode reader<br />

Yes, via USB Yes, via USB<br />

Degree of protection Overall device Overall device<br />

IP65/enclosure IP65/enclosure<br />

type 4x/type 12<br />

(indoor use<br />

type 4x/type 12<br />

(indoor use<br />

Certifications & standards<br />

only)<br />

only)<br />

Certification cULus<br />

cULus<br />

(UL 508),<br />

NEMA4-tested<br />

(UL 508),<br />

NEMA4-tested<br />

EMC CE EN 55011<br />

class A<br />

CE EN 55011<br />

class A<br />

■ Design<br />

■ Integration<br />

Integral interfaces SIMATIC Flat Panel PRO:<br />

Standard VGA interface, 15-pin Sub-D<br />

Digital DVI-D interface<br />

USB interface up to max. 30 m distance from <strong>PC</strong> unit<br />

2 x USB interfaces for connecting local I/Os<br />

(e. g. mouse, keyboard) or mass storage devices such as<br />

USB flash drives<br />

3/10<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Ordering data Order No.<br />

SIMATIC Flat Panel PRO<br />

15" Touch<br />

A 6AV7 861-5TB10-1BA0<br />

SIMATIC Flat Panel PRO<br />

19" Touch<br />

A 6AV7 861-6TB10-1BA0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI devices for special requirements<br />

Fully enclosed HMI devices<br />

■ Technical specifications (continued)<br />

■ Dimensional drawings<br />

Flat Panel PRO 15" PRO 19" All specifications in mm.<br />

Standards, approvals, certificates<br />

Panel cutout see technical specifications.<br />

CE mark Yes Yes<br />

400<br />

UL approval<br />

Ambient conditions<br />

Yes Yes<br />

Vibration load during operation 1 g (10 m/s²) 1 g (10 m/s²)<br />

Shock loading during operation<br />

Temperature<br />

5 g (50 m/s²) 5 g (50 m/s²)<br />

Ambient temperature during<br />

operation<br />

Mounting<br />

5 to +45 °C 5 to +45 °C<br />

Inclination angle +/- 45° from +/- 45° from<br />

Interfaces<br />

the vertical the vertical<br />

Graphics interface Standard VGA Standard VGA<br />

interface 15-pin interface 15-pin<br />

sub-D/digital sub-D/digital<br />

DVI-D interface DVI-D interface<br />

Interface for Touch USB (V1.1) USB (V1.1)<br />

USB interface for touch screen<br />

Dimensions<br />

Yes Yes<br />

External dimensions (W x H x D) 400 mm x 483 mm x<br />

Weight<br />

310 mm x<br />

91 mm<br />

400 mm x<br />

105 mm<br />

SIMATIC Flat Panel PRO 15" Touch<br />

Weight 6.7 kg 10 kg<br />

483<br />

SIMATIC Flat Panel PRO 19" Touch<br />

SIMATIC Flat Panel PRO<br />

SIMATIC FLAT PANEL<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/ip65-hmi-devices<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.<br />

310<br />

67.85<br />

400<br />

82<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

90.85<br />

105<br />

G_<strong>ST</strong><strong>80</strong>_XX_00350<br />

G_<strong>ST</strong><strong>80</strong>_XX_00371<br />

3/11<br />

3


3<br />

HMI devices for special requirements<br />

Fully enclosed HMI devices<br />

SIMATIC HMI I<strong>PC</strong>477C PRO<br />

■ Overview<br />

SIMATIC HMI I<strong>PC</strong>477C PRO 19"<br />

SIMATIC HMI I<strong>PC</strong>477C PRO 19" (rear view)<br />

3/12<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Application<br />

The SIMATIC HMI I<strong>PC</strong>477C PRO is a compact, high-performance<br />

and maintenance-free embedded Panel <strong>PC</strong> – the ideal<br />

platform for <strong>PC</strong>-based Automation on the support arm with<br />

WinCC flexible, WinAC RTX / WinAC RTX F or WinCC Client/<br />

single-user station.<br />

■ Integration<br />

Configuration and integrated interfaces<br />

SIMATIC HMI I<strong>PC</strong>477C PRO:<br />

Intel Core2 Duo to Celeron 1.2 GHz (all without fan)<br />

1 GB to 4 GB RAM<br />

2 GB to 8 GB CF card or 32 GB SSD with Windows XP<br />

embedded<br />

PROFIBUS or PROFINET with IRT onboard (each optional)<br />

2 x or 1 x Ethernet onboard (10/100/1000 Mbit)<br />

4 x USB 2.0 connection<br />

1 x DVI-I<br />

Preinstalled SIMATIC WinCC flexible, WinAC RTX, or WinCC 7<br />

client or single-user system


© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI devices for special requirements<br />

Fully enclosed HMI devices<br />

SIMATIC HMI I<strong>PC</strong>477C PRO<br />

■ Technical specifications<br />

6AV7 883-6….-…0 6AV7 883-7….-…0<br />

General features<br />

Supply voltage 24 V DC 24 V DC<br />

Processors Intel Celeron M 1.2 GHz, Intel Core 2 Solo Intel Celeron M 1.2 GHz, Intel Core 2 Solo<br />

1.2 GHz or Core 2 Duo 1.2 GHz<br />

1.2 GHz or Core 2 Duo 1.2 GHz<br />

Memory type DDR3-RAM DDR3-RAM<br />

Main memory 1 GB, 2 GB or 4 GB 1 GB, 2 GB or 4 GB<br />

Free slots 1 x CF card slot (externally accessible) 1 x CF card slot (externally accessible)<br />

Operating system Windows Embedded Standard 2009 or Windows Embedded Standard 2009 or<br />

Windows XP Professional Multi Language Windows XP Professional Multi Language<br />

Additional OS information Language: En/Ger Language: En/Ger<br />

SIMATIC Software Optionally with preinstalled bundle software Optionally with preinstalled bundle software<br />

SIMATIC WinCC flexible 2008 SP1 and/or SIMATIC WinCC flexible 2008 SP1 and/or<br />

WinAC RTX 2009 SIMATIC WinAC RTX F WinAC RTX 2009 SIMATIC WinAC RTX F<br />

SIMATIC WinCC as web client or standard SIMATIC WinCC as web client or standard<br />

Drives<br />

client<br />

client<br />

Floppy drive optional via external USB floppy drive optional via external USB floppy drive<br />

Optical drives possible as an external drive via USB possible as an external drive via USB<br />

Hard disk/mass storage Compact Flash Drive with 2, 4 or 8 GB Compact Flash Drive with 2, 4 or 8 GB<br />

Interfaces<br />

and/or SSD (Solid State Disk) with 32 GB and/or SSD (Solid State Disk) with 32 GB<br />

Graphics interface DVI-I can be used for additional display unit DVI-I can be used for additional display unit<br />

(only VGA via adapter); 32-bit color depth, (only VGA via adapter); 32-bit color depth,<br />

graphics memory up to 128 MB; resolution as graphics memory up to 128 MB; resolution as<br />

for integrated display in each case<br />

for integrated display in each case<br />

Connection for keyboard/mouse USB / USB USB / USB<br />

serial interface COM1: 1 x V.24 (RS232) COM1: 1 x V.24 (RS232)<br />

PROFIBUS/MPI Optionally onboard, isolated, max. 12 Mbit/s, Optionally onboard, isolated, max. 12 Mbit/s,<br />

no plug-in card required, CP5611-compatible, no plug-in card required, CP5611-compatible,<br />

not upgradable<br />

not upgradable<br />

PROFINET (RT/IRT) Optional: 3 x RJ45, CP1616-compatible; Optional: 3 x RJ45, CP1616-compatible;<br />

not for retrofitting<br />

not for retrofitting<br />

USB 4 x on rear, USB 2.0 (500 mA) 4 x on rear, USB 2.0 (500 mA)<br />

PROFINET (IE), Ethernet onboard, 2 x 10/100/1000 Mbit (RJ45 without/ onboard, 2 x 10/100/1000 Mbit (RJ45 without/<br />

with PROFIBUS), 1 x 10/100/1000 Mbit (RJ45 with PROFIBUS), 1 x 10/100/1000 Mbit (RJ45<br />

with PROFINET), no plug-in card necessary with PROFINET), no plug-in card necessary<br />

Multimedia No No<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

3/13<br />

3


3<br />

HMI devices for special requirements<br />

Fully enclosed HMI devices<br />

SIMATIC HMI I<strong>PC</strong>477C PRO<br />

■ Technical specifications (continued)<br />

6AV7 883-6….-…0 6AV7 883-7….-…0<br />

Monitoring functions<br />

Temperature Yes Yes<br />

Watchdog Yes Yes<br />

DiagBit (similar to S.M.A.R.T.) Yes (for CF cards and SSD) Yes (for CF cards and SSD)<br />

Status LEDs Yes Yes<br />

Front side according to EN 60529<br />

Ambient conditions<br />

IP65 all-round to EN 60529 and NEMA4 IP65 all-round to EN 60529 and NEMA4<br />

Vibration load during operation Tested according to IEC 60068-2-6: 10 to Tested according to IEC 60068-2-6: 10 to<br />

58 Hz: 0.075 mm, 58 to 200 Hz: 9.8 m/s² (1 g) 58 Hz: 0.075 mm, 58 to 200 Hz: 9.8 m/s² (1 g)<br />

Shock loading during operation Tested according to IEC 60068-2-7:<br />

Tested according to IEC 60068-2-7:<br />

50 m/s² (5 g), 30 ms, 100 shocks<br />

50 m/s² (5 g), 30 ms, 100 shocks<br />

Relative humidity Tested according to IEC 68-78,<br />

Tested according to IEC 68-78,<br />

IEC 60068-2-30: 5 % to <strong>80</strong> % at 25 °C<br />

IEC 60068-2-30: 5 % to <strong>80</strong> % at 25 °C<br />

(no condensation)<br />

(no condensation)<br />

Maximum permissible installation angle +/- +/- 45° from the vertical +/- 45° from the vertical<br />

Ambient temperature<br />

Certifications & standards<br />

0 °C to 45 °C 0 °C to 40 °C<br />

Approvals CE, cULus(508) CE, cULus(508)<br />

EMC CE, 55022A, EN 61000-6-4, EN 61000-6-2 CE, 55022A, EN 61000-6-4, EN 61000-6-2<br />

Degree of protection Overall device IP65/enclosure type 4x/type 12 Overall device IP65/enclosure type 4x/type 12<br />

(indoor use only)<br />

(indoor use only)<br />

Dimensions 400 mm x 310 mm x 98 mm 483 mm x 400 mm x 115 mm<br />

Weight 7.4 kg 10.9 kg<br />

3/14<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


HMI devices for special requirements<br />

Fully enclosed HMI devices<br />

■ Ordering data Order No. Order No.<br />

I<strong>PC</strong>477C PRO as "Built to Order" versions<br />

(max. delivery time is 15 working days and with identified repair).<br />

Configuration<br />

SIMATIC HMI I<strong>PC</strong>477C PRO<br />

embedded and without fan, fully<br />

enclosed according to IP65;<br />

5 x (500 mA), one of which on<br />

the front<br />

24 V DC power supply with<br />

On/Off switch<br />

Front panels<br />

E 6AV7 883 - 7 A 7 7 7 - 7 7 7 0<br />

15" TFT Touch 6<br />

19" TFT Touch<br />

Processors and fieldbus<br />

7<br />

Celeron M 1.2 GHz,<br />

2 x PROFINET (IE)<br />

A<br />

Celeron M 1.2 GHz,<br />

2 x PROFINET (IE),<br />

1 x PROFIBUS DP 12<br />

B<br />

Core2 Solo 1.2 GHz,<br />

2 x PROFINET (IE)<br />

D<br />

Core2 Solo 1.2 GHz,<br />

2 x PROFINET (IE),<br />

1 x PROFIBUS DP 12<br />

E<br />

Core2 Solo 1.2 GHz,<br />

1 x PROFINET (IE),<br />

1 x PROFINET (RT/IRT) (3 ports)<br />

F<br />

Core2 Duo 1.2 GHz,<br />

2 x PROFINET (IE)<br />

G<br />

Core2 Duo 1.2 GHz,<br />

2 x PROFINET (IE),<br />

1 x PROFIBUS DP 12<br />

H<br />

Core2 Duo 1.2 GHz,<br />

1 x PROFINET (IE),<br />

1 x PROFINET (RT/IRT) (3 ports)<br />

Main memory (DDR3 RAM),<br />

1 database<br />

J<br />

1 GB 1<br />

2 GB 2<br />

4 GB<br />

Mass storage replaceable<br />

(formatted in a partition)<br />

3<br />

without 0<br />

CompactFlash 2 GB 2<br />

CompactFlash 4 GB 3<br />

CompactFlash 8 GB 4<br />

SSD (Solid State Disk),<br />

min. 32 GB<br />

6<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC HMI I<strong>PC</strong>477C PRO<br />

Configuration (continued)<br />

SIMATIC HMI I<strong>PC</strong>477C PRO<br />

Mass storage (installed, Windows<br />

Embedded Standard 2009<br />

(Ger/En) preinstalled, optionally<br />

with SIMATIC software)<br />

E 6AV7 883 - 7 A 7 7 7 - 7 7 7 0<br />

CompactFlash 2 GB 2<br />

CompactFlash 4 GB 3<br />

CompactFlash 8 GB 4<br />

SSD (Solid State Disk),<br />

min. 32 GB<br />

Operating system<br />

(preinstalled and activated)<br />

6<br />

Windows Embedded Standard<br />

2009<br />

B A<br />

Windows XP Professional<br />

Multi-Language, only with SSD;<br />

without SIMATIC software<br />

D A<br />

Windows Embedded<br />

Standard 7, preinstalled on drive<br />

intern, CF > 4 GByte, SSD<br />

E A<br />

Windows 7 Ultimate, MUI<br />

(En, Ger, Fr, It, Sp)<br />

preinstalled on SD<br />

Software packages<br />

with CF 4 GB or higher<br />

G A<br />

1)<br />

with operating system and RTX<br />

WinAC RTX 2010 pre-installed<br />

and configured<br />

with operating system and HMI,<br />

WinCC flexible 2008 SP2 RT<br />

(incl. archives/recipes) preinstalled<br />

and configured<br />

B B<br />

- Number of tags 128 PT B C<br />

- Number of tags 512 PT B D<br />

- Number of tags 2048 PT B E<br />

- Number of tags 4096 PT<br />

with operating system and<br />

HMI/RTX,<br />

WinCC flexible 2008 SP2 RT<br />

(incl. archives/recipes) and<br />

WinAC RTX 2010<br />

pre-installed and configured<br />

B F<br />

- Number of tags 128 PT B K<br />

- Number of tags 512 PT B L<br />

- Number of tags 2048 PT B M<br />

- Number of tags 4096 PT B N<br />

with operating system and RTX F<br />

WinAC RTX F 2010 pre-installed<br />

and configured<br />

with operating system and<br />

HMI/RTX F<br />

B P<br />

1) ,<br />

WinCC flexible 2008 SP2 RT<br />

(incl. archives/recipes) and<br />

WinAC RTX F 2010<br />

pre-installed and configured<br />

- Number of tags 128 PT B R<br />

- Number of tags 512 PT B S<br />

- Number of tags 2048 PT B T<br />

1) Preferred versions with repaired replacement device from warehouse<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

3/15<br />

3


3<br />

HMI devices for special requirements<br />

Fully enclosed HMI devices<br />

SIMATIC HMI I<strong>PC</strong>477C PRO<br />

■ Dimensional drawings<br />

All specifications in mm.<br />

Panel cutout see technical specifications.<br />

SIMATIC HMI I<strong>PC</strong>477C PRO 15" Touch version<br />

119 400<br />

348.7<br />

105<br />

SIMATIC HMI I<strong>PC</strong>477C PRO 19" Touch version<br />

3/16<br />

400<br />

482.7<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

78.85<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

81.85<br />

G_<strong>ST</strong><strong>80</strong>_XX_00400<br />

G_<strong>ST</strong><strong>80</strong>_XX_00401<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/ip65-hmi-devices<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.


■ Overview<br />

Adapter sets<br />

The adapter sets are required for connecting the SIMATIC<br />

HMI PRO device with the support arm head of the respective<br />

support arm system<br />

By directly connecting the support arm head to the device,<br />

there is complete flexibility in the choice of support arm<br />

components<br />

Adapter sets are available for the VESA 75 and VESA 100<br />

systems.<br />

Further adapter sets can be obtained directly from the<br />

respective supporting bracket manufacturer: Bernstein, Rittal,<br />

Rose and Haseke<br />

■ Integration<br />

The adapter sets are connected to the SIMATIC HMI PRO<br />

devices by means of the basic adapter. The support arm head<br />

is connected directly to the adapter plate.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI devices for special requirements<br />

Accessories for fully enclosed HMI devices<br />

■ Ordering data Order No.<br />

VESA 100 adapter set 1) for<br />

VESA 100<br />

Rose GTN II<br />

A 6AV7 674-0KD00-0AA0<br />

VESA 75 adapter set for<br />

VESA 75<br />

A 6AV7 674-0KE00-0AA0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Adapter sets<br />

1) The VESA 100 adapter set cannot be used in combination with the<br />

19" Flat Panel PRO.<br />

Note:<br />

The internal diameter of the 48 mm supporting bracket tubes is not<br />

suitable for passage of the standard DVI-D cable.<br />

Scope of delivery:<br />

1 adapter plate<br />

Mounting hardware<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/ip65-hmi-devices<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.<br />

3/17<br />

3


3<br />

HMI devices for special requirements<br />

Accessories for fully enclosed HMI devices<br />

Extension units<br />

■ Overview<br />

■ Ordering data Order No.<br />

Extension unit 15"<br />

For mounting on all 15"<br />

PRO devices<br />

A 6AV7 674-0KG00-0AA0<br />

Extension unit 15" KP8<br />

For mounting on all 15"<br />

PRO devices for direct installation<br />

of up to 2 KP8 / KP8F<br />

A 6AV7 674-0KG01-0AA0<br />

Extension unit 19" right<br />

For support arm mounting from<br />

top mounting of the extension<br />

unit on the right side of the 19"<br />

PRO device<br />

For support arm mounting from<br />

below mounting of the extension<br />

unit on the left side of the 19"<br />

PRO device<br />

A 6AV7 674-0KJ00-0AA0<br />

Extension unit 19" KP8 right<br />

For support arm mounting from<br />

top mounting of the extension<br />

A 6AV7 674-0KJ01-0AA0<br />

Extension units<br />

unit on the right side of the 19"<br />

PRO device<br />

With the extension units, the range of possible on-site operations<br />

can be extended. They are mounted on the SIMATIC HMI PRO<br />

For support arm mounting from<br />

below mounting of the extension<br />

device and can be equipped individually, e.g. with<br />

unit on the left side of the 19"<br />

3SB elements, emergency stop buttons, key switches,<br />

PRO device<br />

RFID reader, etc.<br />

For direct installation of up to<br />

They can be mounted on the left or right side of the<br />

PRO device, as required<br />

2 KP8 / KP8F<br />

Extension unit 19" left A 6AV7 674-0KH00-0AA0<br />

Direct installation of up to 2 Key Panels KP8 / KP8F<br />

IP65 - cable routing<br />

For support arm mounting from<br />

top mounting of the extension<br />

unit on the left side of the 19"<br />

Can be equipped individually<br />

For all 15"/19" PRO devices<br />

PRO device<br />

For support arm mounting from<br />

below mounting of the extension<br />

The combination of HMI PRO device and KP8 PN offers the<br />

following advantages:<br />

No control cabinet required<br />

Low cabling overhead<br />

unit on the right side of the 19"<br />

PRO device<br />

Extension unit 19" KP8 left A<br />

For support arm mounting from<br />

top mounting of the extension<br />

6AV7 674-0KH01-0AA0<br />

Optimally coordinated design<br />

unit on the left side of the 19"<br />

PRO device<br />

■ Integration<br />

For support arm mounting from<br />

below mounting of the extension<br />

The extension unit is mounted on the left and/or right side of the<br />

SIMATIC PRO device, as required. The cable is routed through<br />

the "connecting tube", which connects the extension unit to the<br />

basic adapter and thus to the support arm. The new SIMATIC<br />

Key Panel facilitates the integration of keys and indicator lights<br />

in the extension unit considerably. The operator controls must<br />

now no longer be individually wired. Instead, control is<br />

performed directly via PROFINET. Each extension unit can<br />

accommodate up to two KP8 PN. Of course, you can connect<br />

further elements such as emergency stop units and keyoperated<br />

switches on the rear side of the Key Panel.<br />

unit on the right side of the 19"<br />

PRO device<br />

For direct installation of up to<br />

2 KP8 / KP8 F<br />

KP8 front plate for the A<br />

extension unit<br />

For installing up to two KP8 in an<br />

extension unit<br />

Suits all extension units 15“ and<br />

19“<br />

Spare front plate for the A<br />

extension unit<br />

6AV7 674-0KH30-0AB0<br />

6AV7 674-0KH30-0AA0<br />

■ More information<br />

Suits all extension units 15“ and<br />

19“<br />

Additional information is available on the Internet at:<br />

Required if the front plate<br />

supplied with the extension unit<br />

www.siemens.com/ip65-hmi-devices<br />

must be replaced<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.<br />

3/18<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Scope of delivery:<br />

1 extension unit box<br />

1 front plate for the extension unit<br />

1 connecting tube<br />

Mounting accessories


■ Overview<br />

■ Integration<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI devices for special requirements<br />

Accessories for fully enclosed HMI devices<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

IP65 keyboards<br />

■ Ordering data Order No.<br />

IP65 keyboards<br />

The range of possible on-site operations can be extended with<br />

the stainless steel IP65 keyboards. They are mounted on the<br />

SIMATIC HMI PRO device underneath the base adapter, and<br />

they are available in two versions.<br />

Stainless steel IP65<br />

A<br />

keyboard 15"<br />

Width: 400 mm (adapted to 15"<br />

SIMATIC HMI PRO)<br />

Windows layout (EN/US) without<br />

NUM block<br />

6AV7 674-0NC00-0AA0<br />

Anti-twist and non-removable stainless steel key caps<br />

Angle-adjustable adapter<br />

Abrasion-resistant laser labeling (depth engraving with<br />

Stainless steel IP65<br />

A 6AV7 674-0NE00-0AA0<br />

annealing marking)<br />

keyboard 19"<br />

Secure, pleasant key feel<br />

Maximum user-friendliness thanks to withdrawable longstroke<br />

key<br />

Width: 483 mm (adapted to 19"<br />

SIMATIC HMI PRO)<br />

Windows layout (EN/US) with<br />

NUM block<br />

Windows layout (EN/US) with two additional keys<br />

Angle-adjustable adapter<br />

(left and right mouse key function) via cursor block<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

USB interface<br />

Angle-adjustable connection for optimal ergonomics<br />

Water and dust protection in accordance with degree of<br />

protection IP65<br />

For all 15"/19" PRO devices<br />

Scope of delivery:<br />

1 stainless steel IP65 keyboard incl. mounting adapter for<br />

PRO devices<br />

Mounting accessories<br />

■ More information<br />

The stainless steel IP65 keyboard is mounted on the SIMATIC Additional information is available on the Internet at:<br />

PRO device under the base adapter. The cable is run via the<br />

keyboard adapter in the base adapter.<br />

www.siemens.com/ip65-hmi-devices<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products" you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.<br />

3/19<br />

3


3<br />

HMI devices for special requirements<br />

Accessories for fully enclosed HMI devices<br />

Single-port USB interface<br />

■ Overview<br />

The USB interface is used for connecting external I/O devices<br />

to the MP 377 PRO, the Thin Client PRO, the Flat Panels PRO,<br />

and the HMI I<strong>PC</strong>477C PRO.<br />

USB I/O can thus be connected and operated without opening<br />

the device<br />

Extension of the internal USB interface externally<br />

■ Design<br />

The installation of the USB interface is especially practical if<br />

external input devices or mass storage devices frequently have<br />

to be connected to the SIMATIC HMI PRO device.<br />

The USB interface can optionally be mounted at the top or<br />

bottom of the device.<br />

Use of the USB interface increases the availability of the<br />

system to be operated. The backplane of the SIMATIC HMI<br />

PRO device no longer has to be opened in order to connect<br />

IO devices. The device can thus be operated without<br />

interruption.<br />

The USB interface offers the following advantages:<br />

Accessible without tools<br />

For retrofitting in enclosure<br />

Can be mounted either above or below<br />

IP65 protection if protective cover is closed<br />

Undetachable protective cover<br />

■ Integration<br />

The USB interface is suitable, for example, for the connection of:<br />

Mouse<br />

Keyboard<br />

Suitable for SIMATIC MP 377 PRO, SIMATIC Thin Client PRO,<br />

SIMATIC Flat Panel PRO, and the HMI I<strong>PC</strong>477C PRO.<br />

3/20<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Ordering data Order No.<br />

1-port USB interface A 6AV7 674-0LX00-0AA0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/ip65-hmi-devices<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.


■ Overview<br />

For special requirements, the following HMI devices with<br />

stainless steel front (EN 1672-2), e. g. for use in the food,<br />

beverages and tobacco industries, are offered.<br />

SIMATIC TP 177B INOX<br />

Touch Panel with stainless steel front (EN 1672-2) for the<br />

additionally higher requirements from the food and beverages<br />

sector, for example.<br />

Comprehensive functionality for operator control and<br />

monitoring of machines and plants<br />

Pixel graphics display with analog touch screen<br />

5.7" <strong>ST</strong>N Color<br />

All interfaces for communication with <strong>Siemens</strong> SIMATIC S7<br />

(e. g. MPI, PROFIBUS DP) are on board<br />

PROFINET interface already on board in color version<br />

Drivers are also available for non-<strong>Siemens</strong> PLCs<br />

Data in the message buffer is retained even if panel is<br />

switched off, without battery<br />

SIMATIC MP 277 INOX<br />

Like operator panels, Multi Panels (MP) are used for local<br />

machine operation and monitoring.<br />

Data in the message buffer is retained even if panel is<br />

switched off, without battery<br />

PLC functionality can be integrated directly into the MP 277<br />

platform with Option<br />

Their functionality can be expanded by installing additional<br />

Windows CE applications (Multi Panel and Panel options)<br />

SIMATIC MP 277 devices on the basis of Windows CE<br />

combine the rugged construction of Operator Panels with the<br />

flexibility of <strong>PC</strong>s<br />

Pixel graphics 10.4" TFT display, color (64k colors)<br />

Touch screen (analog/resistive)<br />

All interfaces, e. g. MPI, PROFIBUS DP, USB, PROFINET<br />

(Ethernet TCP/IP), are on-board<br />

SIMATIC MP 377 INOX<br />

Like operator panels, Multi Panels (MP) are used for local<br />

machine operation and monitoring.<br />

Their functionality can be expanded by installing additional<br />

Windows CE applications (Multi Panel and Panel options)<br />

SIMATIC MP 377 INOX devices on the basis of Windows CE<br />

combine the rugged construction of Operator Panels with the<br />

flexibility of <strong>PC</strong>s<br />

PLC functionality can be integrated directly into the MP 377<br />

platform with Option<br />

Pixel graphics 15" TFT display, color (64k colors)<br />

Touch screen (analog/resistive)<br />

All interfaces, e. g. MPI, PROFIBUS DP, USB, PROFINET<br />

(Ethernet TCP/IP), are on-board<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI devices for special requirements<br />

Devices with stainless steel front<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Introduction<br />

SIMATIC Panel <strong>PC</strong> 677B INOX<br />

<strong>PC</strong> platform with high degree of industrial compatibility for<br />

demanding tasks in the area of <strong>PC</strong>-based automation.<br />

Rugged construction:<br />

The <strong>PC</strong> is resistant to the harshest mechanical stress and is<br />

reliable in operation.<br />

Compact design<br />

High degree of investment protection<br />

Fast integration capability<br />

15" TFT Touch, stainless steel/INOX<br />

The operator control unit and computing unit can be placed<br />

30 m apart (optional)<br />

SIMATIC HMI I<strong>PC</strong>677C INOX<br />

<strong>PC</strong> platform with high degree of industrial compatibility for<br />

demanding tasks in the area of <strong>PC</strong>-based automation.<br />

Rugged construction:<br />

The <strong>PC</strong> is resistant to the harshest mechanical stress and is<br />

reliable in operation.<br />

Compact design<br />

High degree of investment protection<br />

Fast integration capability<br />

15" TFT Touch, stainless steel/INOX<br />

All interfaces such as PROFIBUS or PROFINET onboard<br />

3/21<br />

3


3<br />

HMI devices for special requirements<br />

Devices with stainless steel front<br />

SIMATIC TP 177B INOX<br />

■ Overview<br />

Touch Panel with stainless steel front (EN 1672-2) for<br />

additional increased requirements, e. g. in the food and<br />

beverages industry<br />

Comprehensive functionality for operator control and<br />

monitoring of machines and plants<br />

Pixel graphics display with analog touch screen<br />

- 5.7" <strong>ST</strong>N Color<br />

All interfaces for communication with <strong>Siemens</strong> SIMATIC S7<br />

(e. g. MPI, PROFIBUS DP) are on board<br />

PROFINET interface already on board in color version<br />

Drivers for controls from other manufacturers are also<br />

available<br />

Data in the message buffer is retained even if panel is<br />

switched off, without battery<br />

■ Benefits<br />

Reduction of service and commissioning costs due to:<br />

- Backup/restore via a process interface or optionally via a<br />

Multi Media Card<br />

- Download of the image and configuration across all device<br />

interfaces<br />

- Maintenance-free design and long service life of backlit<br />

display<br />

Data in the message buffer is retained even if panel is<br />

switched off, without battery.<br />

Can be used worldwide:<br />

- 32 online languages (incl. Asian and Cyrillic character sets)<br />

can be configured<br />

- Online languages can be selected direct on the device<br />

Graphic library with preconfigured screen objects<br />

Standard interfaces for increasing flexibility:<br />

- ext. Multi Media Card, can be used for recipe data records<br />

and backing up of configuration/system data;<br />

Integrated USB interface for connecting standard printers, for<br />

example<br />

Simple engineering supported by detailed documentation on<br />

the SIMATIC HMI Manual Collection DVD<br />

Integrated component of Totally Integrated Automation (TIA):<br />

Increase of productivity, minimization of engineering<br />

overhead, reduction of lifecycle costs<br />

Due to the stainless steel front of the panel, it can also be<br />

optimally used in the food and beverages and pharmaceutical<br />

sectors. Its front is designed such that it can be cleaned and<br />

disinfected easily. Furthermore, liquids flow off automatically<br />

from the front. In addition, the stainless steel front (incl. seal)<br />

provides protection against contamination with foodstuff.<br />

3/22<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Application<br />

Thanks to their practical functions and large user memory,<br />

TP 177B INOX Touch Panels can be used wherever operator<br />

control and monitoring of machines and plants is necessary on<br />

site – whether in production automation, process automation, or<br />

building-services automation. The TP 177B INOX has a<br />

5.7" <strong>ST</strong>N display with 256 colors and features an integrated<br />

PROFINET I/O interface. A USB interface is standard. A further<br />

highlight is the non-volatile message buffer included as<br />

standard that stores messages permanently without battery<br />

backup.<br />

The TP 177B INOX has been designed for all industries that<br />

require a stainless steel front. The front can be disinfected and<br />

does not affect the quality e. g. of foods (assuming regular<br />

cleaning). Cleaning can be carried out using pressurized water<br />

with a jet of 100 l/min at 1 bar from a distance of 2.5 to 3 m.<br />

Liquids flow off automatically from the front.<br />

■ Design<br />

Display<br />

- 5.7" <strong>ST</strong>N display with 256 colors<br />

LED or CCFL 1) backlighting with long service life<br />

Analog resistive touch screen<br />

Numeric and alphanumeric on-screen keyboard<br />

High performance due to RISC processor and 2 MB user<br />

memory, plus additional integrated recipe memory<br />

Data in the message buffer is retained even if panel is<br />

switched off, without battery<br />

Interfaces MPI, PROFIBUS DP (up to 12 MBaud) and USB 1.1<br />

(max. 100 mA) on board<br />

PROFINET interface<br />

Configuration SIMATIC WinCC flexible 2005 Compact or<br />

higher<br />

Complete functionality for complex tasks<br />

Comprehensive Reichert graphic library<br />

Multi Media Card slot, can be used for standard Multi Media<br />

Cards (for backup/restore and for backup of recipe data<br />

records of the configuration as well as of the system data)<br />

SINUMERIK, Sm@rtAccess und Sm@rtService options can be<br />

used<br />

Service-friendly due to maintenance free design and long<br />

service life of the backlit display<br />

1) Cold Cathode Fluorescence Lamps


■ Function<br />

Permanent window and templates concept<br />

for creating screen models<br />

Input/output fields<br />

for visualizing and editing process parameters<br />

Configurable buttons with up to 16 functions simultaneously<br />

for direct triggering of functions and actions<br />

Indicator light<br />

for indicating machine and plant states<br />

Predefined texts<br />

for labeling function keys, mimics, and process values with<br />

characters in any size<br />

Help texts<br />

for mimics, alarms, and variables<br />

Vector graphic, graphics<br />

can be used as icon instead of text for "labeling" buttons.<br />

They can also be created as screen background images.<br />

A library with many graphics and diverse objects is available<br />

in the configuration tool. All editors with "OLE" interface can be<br />

used as graphic editor, e. g. Paint-Shop, Designer,<br />

Corel Draw, etc.<br />

Trend functions and bar graphs<br />

are used for the graphic display of dynamic values<br />

Dynamic positioning of objects and dynamic showing/hiding<br />

of objects<br />

Computing functions, limit monitoring<br />

for reliable process control at inputs and outputs<br />

Online language switching<br />

with 16 selectable languages, incl. Asian and Cyrillic<br />

languages, also for language-dependent graphics<br />

Scheduler<br />

for cyclic function processing<br />

Password protection (security)<br />

user administration – log on through user ID and password, in<br />

addition user group-specific rights as integral part of SIMATIC<br />

Signaling system<br />

Freely-definable message classes (acknowledgment<br />

response and display can be configured). Administration of<br />

status messages, fault messages, and system alarms. The<br />

alarm history is retained even when device is switched off.<br />

Analog alarms (limit alarms) in addition to discrete alarms.<br />

Recipe management:<br />

with additional data storage (on ext. memory medium)<br />

Online/offline processing on the panel<br />

Storage of recipe data in standard Windows format (CSV)<br />

External processing using standard tools such as Excel,<br />

Access is possible<br />

Multi Media Card slot<br />

for external standard data carriers, can be used for backup/<br />

restore or for transporting recipe data records;<br />

Facilitates service and configuration due to:<br />

- Backup and restoring of configuration, operating system,<br />

data records, and firmware on a <strong>PC</strong> using ProSave<br />

- Possible download/upload of configuration via all device<br />

interfaces (with automatic transfer detection)<br />

- Individual contrast setting and calibration<br />

- Simulation of the configuration direct on the configuring <strong>PC</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI devices for special requirements<br />

Devices with stainless steel front<br />

SIMATIC TP 177B INOX<br />

Configuration<br />

Configuration is implemented using the innovative engineering<br />

tool SIMATIC WinCC flexible 2005, Compact Edition or higher.<br />

SIMATIC WinCC flexible is the consistent further development of<br />

the tried and tested ProTool family. Projects created using<br />

ProTool can be easily migrated to WinCC. When implementing<br />

OP17 projects, the project engineer must implement corresponding<br />

adaptations after the conversion due to the innovated<br />

display technology. However, WinCC flexible provides support<br />

for this! If WinCC flexible is started direct from SIMATIC<br />

Manager, the data in Step 7 can be accessed directly when<br />

configuring the panel. Double data entries and data storage is<br />

thus avoided.<br />

Additional options<br />

SINUMERIK<br />

Optionally with "Sinumerik HMI copy license<br />

WinCC flexible CE". The "SINUMERIK HMI engineering<br />

package WinCC flexible" is additionally required for<br />

configuration. For further information, see <strong>Catalog</strong> NC 60.<br />

Sm@rtService<br />

Remote control and monitoring of SIMATIC HMI systems<br />

based on TCP/IP networks<br />

Sm@rtAccess<br />

Communication between HMI systems based on TCP/IP<br />

networks. Remote access to recipe data records, passwords,<br />

HMI system-specific information, and much more.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

3/23<br />

3


3<br />

HMI devices for special requirements<br />

Devices with stainless steel front<br />

SIMATIC TP 177B INOX<br />

■ Technical specifications<br />

6AV6 642-8BA10-0AA0<br />

Product type designation<br />

TP 177B color INOX<br />

(with stainless steel front)<br />

Display<br />

Size 5.7" (120 mm x 90 mm)<br />

Display type <strong>ST</strong>N, 256 Farben<br />

Resolution (pixels)<br />

Resolution (WxH in pixel) 320 x 240<br />

Backlighting<br />

MTBF backlighting (at 25 °C) about 50,000 hours<br />

Control elements<br />

Control elements Touch screen<br />

Connection for mouse/keyboard/ USB / USB / USB<br />

barcode reader<br />

Keyboard<br />

Numeric/alphabetical input Yes / Yes<br />

Touch operation<br />

Touch screen analog, resistive<br />

Supply voltage<br />

Input voltage<br />

permissible range +18 V to +30 V DC<br />

Supply voltage 24 V DC<br />

Input current<br />

Rated current 0.24 A<br />

Processor<br />

Processor ARM, 200 MHz<br />

Memory<br />

Type Flash / RAM<br />

Usable memory for user data 2048 KB usable memory for user<br />

data<br />

Time of day<br />

Clock<br />

Type Hardware clock, synchronizable,<br />

no battery backup<br />

Interfaces<br />

USB port 1 x USB<br />

<strong>PC</strong> card slot No<br />

CF card slot No<br />

Multi Media Card slot 1 x Multi Media Card slot<br />

Industrial Ethernet<br />

Industrial Ethernet interface 1 x Ethernet (RJ45)<br />

Protocols<br />

Protocols (terminal link)<br />

Sm@rtAccess Yes<br />

Ambient conditions<br />

Operating temperature<br />

Operation (vertical installation) 0 °C to +50 °C<br />

Operation (max. tilt angle) 0 °C to +40 °C<br />

Storage/transport temperature<br />

Transport, storage -20 °C to +60 °C<br />

Relative humidity<br />

max. relative humidity 90 %<br />

Mounting position vertical<br />

maximum permissible angle of incli- +/- 35 °<br />

nation without external ventilation<br />

Degree and class of protection<br />

Front IP66K, NEMA 4, NEMA 4x,<br />

NEMA 12 (when installed)<br />

Rear IP20<br />

3/24<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV6 642-8BA10-0AA0<br />

Product type designation<br />

TP 177B color INOX<br />

(with stainless steel front)<br />

Standards, approvals, certificates<br />

Certifications CE, GL, ABS, BV, DNV, LRS, PRS,<br />

FM Class I Div. 2, UL, CSA,<br />

cULus, EX-Zone 2/22, Gost-R,<br />

C-TICK, NEMA 4, NEMA 4x,<br />

NEMA 12<br />

Operating systems<br />

Operating system Windows CE<br />

Configuration<br />

Configuration software<br />

Configuration tool see "Configuration overview" from<br />

page 2/3<br />

Functionality under<br />

WinCC flexible<br />

Applications/options see chapter 4: HMI software/<br />

SIMATIC WinCC flexible options<br />

and SIMATIC WinCC (TIA portal)<br />

options.<br />

Task planner Yes<br />

Help system Yes<br />

Status/control with SIMATIC S7<br />

With alarm logging system<br />

(incl. buffer and acknowledgment)<br />

Number of messages 2000<br />

Bit messages Yes<br />

Analog messages Yes<br />

Message buffer Ring buffer (n x 256 entries),<br />

retentive, maintenance-free<br />

Recipes<br />

Recipes 100<br />

Data records per recipe 200<br />

Entries per data record 200<br />

Recipe memory 32 KB integrated Flash,<br />

expandable<br />

Number of process images<br />

Process images 500<br />

Variables 1000<br />

Limit values Yes<br />

Multiplexing Yes<br />

Image elements<br />

Text objects 2,500 text elements<br />

Graphics object Bit maps, icons, icon (full-screen),<br />

vector graphics<br />

dynamic objects Diagrams, bar graphs, sliders,<br />

analog display, invisible buttons<br />

Lists<br />

Text lists 300<br />

Graphics list 100<br />

Libraries Yes<br />

Security<br />

Number of user groups 50<br />

Passwords exportable Yes<br />

Number of user rights 32<br />

Data carrier support<br />

<strong>PC</strong> card No<br />

CF card No<br />

Multimedia Card Yes<br />

Recording<br />

Recording/Printing Alarms, report (shift report),<br />

color print, hardcopy<br />

Printer driver ESC/P2, <strong>PC</strong>L3/<strong>PC</strong>L6<br />

Fonts<br />

Keyboard fonts US American (English)


■ Technical specifications (continued)<br />

Product type designation<br />

Languages<br />

Configuration languages D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified", DK, FIN, GR, J,<br />

KP / ROK, NL, N, PL, P, RUS, S,<br />

CZ / SK, TR, H<br />

Character sets Tahoma, Courier New, WinCC<br />

flexible Standard, symbol<br />

languages, 2 additional character<br />

sets can be loaded, all freely<br />

scalable<br />

Transfer (upload/download)<br />

Transfer of configuration MPI/PROFIBUS DP, serial, USB,<br />

Ethernet, by means of external<br />

storage medium, automatic<br />

transfer recognition<br />

Process coupling<br />

Connection to controller see "System interfaces" from<br />

page 2/179<br />

Expandability/openness<br />

Open Platform Program Yes<br />

I/O<br />

I/O devices Printer<br />

Dimensions and weight<br />

Dimensions<br />

Front of enclosure (W x H) 212 mm x 156 mm<br />

Mounting cutout/device depth<br />

(W x H)<br />

Weight<br />

Weight 0.9 kg<br />

6AV6 642-8BA10-0AA0<br />

TP 177B color INOX<br />

(with stainless steel front)<br />

198 mm x 142 mm / 46 mm<br />

device depth<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI devices for special requirements<br />

Devices with stainless steel front<br />

SIMATIC TP 177B INOX<br />

■ Ordering data Order No.<br />

SIMATIC TP 177B INOX<br />

Touch Panel with<br />

5.7" <strong>ST</strong>N color display<br />

(256 colors) with stainless steel<br />

front<br />

incl. mounting accessories<br />

Configuration software<br />

E 6AV6 642-8BA10-0AA0<br />

with SIMATIC WinCC flexible<br />

Configuration set<br />

Consisting of:<br />

SIMATIC WinCC flexible Compact<br />

engineering software,<br />

SIMATIC HMI Manual Collection<br />

(DVD), 5 languages (English,<br />

French, German, Italian and<br />

Spanish), <strong>PC</strong>/PPI cable Multimaster,<br />

MPI cable (5 m) (for<br />

download and test purposes only)<br />

see HMI software<br />

with SIMATIC WinCC flexible<br />

Compact engineering software<br />

Documentation<br />

(to be ordered separately)<br />

Operating Instructions<br />

TP 177micro/TP 177A/TP 177B/<br />

OP 177B (WinCC flexible)<br />

D 6AV6 621-0AA01-0AA0<br />

German 6AV6 691-1DG01-0AA1<br />

English 6AV6 691-1DG01-0AB1<br />

French 6AV6 691-1DG01-0AC1<br />

Italian 6AV6 691-1DG01-0AD1<br />

Spanish<br />

User Manual<br />

WinCC flexible Compact/<br />

Standard/Advanced<br />

6AV6 691-1DG01-0AE1<br />

German 6AV6 691-1AB01-3AA0<br />

English 6AV6 691-1AB01-3AB0<br />

French 6AV6 691-1AB01-3AC0<br />

Italian 6AV6 691-1AB01-3AD0<br />

Spanish<br />

User Manual<br />

WinCC flexible Communication<br />

6AV6 691-1AB01-3AE0<br />

German 6AV6 691-1CA01-3AA0<br />

English 6AV6 691-1CA01-3AB0<br />

French 6AV6 691-1CA01-3AC0<br />

Italian 6AV6 691-1CA01-3AD0<br />

Spanish 6AV6 691-1CA01-3AE0<br />

SIMATIC HMI Manual Collection B<br />

Electronic documentation, on<br />

DVD<br />

5 languages (English, French,<br />

German, Italian and Spanish);<br />

contains: all currently available<br />

user manuals, manuals and<br />

communication manuals for<br />

SIMATIC HMI<br />

6AV6 691-1SA01-0AX0<br />

Accessories for supplementary<br />

ordering<br />

see HMI accessories<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

3/25<br />

3


3<br />

HMI devices for special requirements<br />

Devices with stainless steel front<br />

SIMATIC TP 177B INOX<br />

■ Dimensional drawings<br />

All specifications in mm.<br />

Panel cutout see technical specifications.<br />

SIMATIC TP 177B PN/DP INOX<br />

3/26<br />

212<br />

196<br />

156<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

140<br />

3<br />

50<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00315<br />

■ More information<br />

Additional information is available in the Internet under:<br />

www.siemens.com/inox-hmi-devices<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.


■ Overview<br />

Like operator panels, Multi Panels (MP) are used for local<br />

machine operation and monitoring<br />

Data in the message buffer is retained even if panel is<br />

switched off, without battery<br />

PLC functionality can be integrated directly into the MP 277<br />

platform with Option<br />

Their functionality can be expanded by installing additional<br />

Windows CE applications (Multi Panel and Panel options)<br />

SIMATIC MP 277 devices on the basis of Windows CE<br />

combine the rugged construction of Operator Panels with<br />

the flexibility of <strong>PC</strong>s<br />

Pixel graphic 10.4" TFT display, color (64k colors)<br />

Touch screen (analog/resistive)<br />

The MP 277 INOX is available with stainless steel front<br />

(EN 1672-2). These versions expand the application area of<br />

the Multi Panels 277 for special applications, ambient<br />

conditions, and special sectors, e. g. in the food, beverage<br />

and tobacco industries.<br />

All interfaces, e. g. MPI, PROFIBUS DP, USB, PROFINET<br />

(Ethernet TCP/IP), are on-board<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI devices for special requirements<br />

Devices with stainless steel front<br />

■ Benefits<br />

SIMATIC MP 277 INOX<br />

Integral component of Totally Integrated Automation (TIA):<br />

Increase of productivity, minimization of engineering<br />

overhead, reduction of lifecycle costs<br />

Modular expansion capability with options such as:<br />

- WinAC MP for MP 277/software PLC<br />

- WinCC flexible /Sm@rtAccess for communication between<br />

different SIMATIC HMI systems<br />

- WinCC flexible /Sm@rtService for remote maintenance and<br />

servicing of machines/plants via the Internet/intranet<br />

- WinCC flexible /O<strong>PC</strong> server for communication with<br />

applications from different manufacturers<br />

- MS Pocket Internet Explorer (included in scope of delivery)<br />

IE6 for Win CE is integrated for WinCC flexible 2007 or<br />

higher.<br />

- WinCC flexible /ProAgent for targeted and quick process<br />

fault diagnostics in plants and machines<br />

- WinCC flexible /Audit for user administration (traceability of<br />

all operator actions)<br />

Reduction of service and commissioning costs due to:<br />

- Backup/restore via Ethernet (TCP/IP), USB, MPI,<br />

PROFIBUS DP or optionally via SD/Multimedia Card<br />

- Remote download/upload of the configuration and firmware<br />

(remote = automatic transfer detection)<br />

- Specific drivers can be reloaded<br />

- Long service life of the backlit display<br />

Graphic library with preconfigured screen objects<br />

Can be used worldwide:<br />

- 32 online languages (incl. Asian and Cyrillic character sets)<br />

can be configured<br />

- Up to 16 languages can be selected online<br />

Standard hardware and software interfaces for increasing<br />

flexibility:<br />

- SD/Multimedia Card slot for memory expansions, backup/<br />

restore, or additional interfaces<br />

- Ethernet (TCP/IP) possible for central data and project<br />

administration; control interfacing to SIMATIC S7 possible<br />

- Standard Windows storage formats (CSV) for archives and<br />

recipes permits further processing using standard tools<br />

(e.g. MS Excel)<br />

■ Application<br />

They are used in the most diverse branches and applications<br />

and can be expanded in their applications with the Multi Panel<br />

options, e. g. for displaying HTML documents via the MS Pocket<br />

Internet Explorer.<br />

The diskless and fanless design enables implementation in<br />

areas where high vibration or dust load limits the operation of<br />

a <strong>PC</strong>. Short boot-up times make the Multi Panels ready for<br />

operation sooner as well.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

3/27<br />

3


3<br />

HMI devices for special requirements<br />

Devices with stainless steel front<br />

SIMATIC MP 277 INOX<br />

■ Design<br />

Compact design with low mounting depth<br />

The front is resistant to various oils, greases and standard<br />

detergents<br />

Degree of protection IP66/NEMA 4x/NEMA 12 (front) or IP20<br />

(rear)<br />

Plug-in terminals for 24 V DC power supply<br />

Interfaces:<br />

- RS 485/RS 422 interface for process connections (PPI, MPI,<br />

PROFIBUS DP up to 12 Mbit/s)<br />

- USB for memory stick, mouse, keyboard, printer, barcode<br />

reader, UPS and downloading/uploading the configuration<br />

- Ethernet (TCP/IP) for exchanging data with a higher-level<br />

<strong>PC</strong>, for connection of a network printer and downloading/<br />

uploading the configuration;<br />

a control link to SIMATIC S7 is possible<br />

Slot for SD/Multimedia Card<br />

■ Function<br />

Display and changing of process parameters<br />

Process display:<br />

- VGA resolution (640 x 4<strong>80</strong> pixels)<br />

with 64k colors each for display elements<br />

- Vector graphic (various line and plane objects)<br />

- Dynamic positioning and dynamic showing/hiding of objects<br />

- Pixel graphic images, trend and bar graph display<br />

- Representation of up to 8 curves in a trend field;<br />

Trend curve graphic with scroll and zoom functions for<br />

accessing the history and flexible selection of the<br />

representation period;<br />

read ruler for determining current values and display in a table<br />

- Comprehensive graphic libraries (SIMATIC HMI Symbol<br />

Library)<br />

- Icons: slider, gauge, clock<br />

- Cyclic function processing by alarm clock<br />

Multiplex function for variables<br />

Signaling system<br />

- Discrete alarms and analog alarms (limit alarms)<br />

- Freely-definable message classes (e. g. status/fault<br />

messages) for definition of acknowledgment response and<br />

display of message events<br />

- Status and fault messages with message history<br />

- Non-volatile, maintenance-free message buffer<br />

- Alarm window and message line<br />

Archiving of messages and process values (on CF/SD/<br />

multimedia card/USB flash drive, etc. or network drives via<br />

Ethernet)<br />

- Various archive types: Circular buffer and sequential buffer<br />

- Storage of archive data in standard Windows format (CSV)<br />

- Online evaluation of process value archives using trend<br />

curves<br />

- External evaluation using standard tools (MS Excel,<br />

MS Access) is possible<br />

Alarm log and shift log<br />

Print functions (see "Recommended printers")<br />

Language switching<br />

- 16 online languages, 32 configuring languages, incl. Asian<br />

and Cyrillic character sets; language-dependent texts and<br />

graphics<br />

3/28<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Recipe management<br />

- With additional data storage (on SD/MultiMediaCard)<br />

- Online/offline processing on the panel<br />

- Storage of recipe data in standard Windows format (CSV)<br />

- External processing using standard tools (MS Excel,<br />

MS Access) is possible<br />

TIA runtime functionalities<br />

- Direct keys (fast keys; for Key as keyboard image, can be<br />

defined by user for Touch) can be used directly as<br />

PROFIBUS DP or PROFINET IO input I/O<br />

- For Key versions, LEDs additionally as output I/O<br />

- As well as Alarm S message frame procedure for<br />

SIMATIC S7 and SIMOTION<br />

- PG functionality <strong>ST</strong>ATUS FORCE-VAR in combination with<br />

SIMATIC S7<br />

- SIMATIC barcode scanner<br />

- Direct connection and evaluation of a SITOP UPS via USB<br />

Screen selection from PLC<br />

permits operator control from the PLC<br />

Display of HTML documents using MS Pocket Internet<br />

Explorer<br />

Visual Basic Script, flexibility through implementing new<br />

functions incl. interfacing to variables (comparison<br />

operations, loop-through, etc.)<br />

Help texts<br />

for mimics, alarms, and variables<br />

Computing functions<br />

Limit monitoring<br />

for reliable process control at inputs and outputs<br />

Permanent window;<br />

fixed upper screen area for output of screen-independent<br />

information (e. g. important process variables, data, and<br />

time-of-day)<br />

Facilitates service and configuration due to<br />

- Backup and restoring (Backup/Restore -> Image) of the<br />

complete (incl. license keys with WinCC flexible 2007 or<br />

higher) Panel on an SD/multimedia card (optional) possible,<br />

also through remote access (Sm@rtService)<br />

- Backup and restoring (Backup/Restore -> Image) of the<br />

complete Panel (except license keys) on a <strong>PC</strong><br />

- Download of configuration via Ethernet/USB/MPI/<br />

PROFIBUS DP/modem/http<br />

- Upload via Ethernet/USB/MPI/PROFIBUS DP/modem/http;<br />

for downloading, the project is optionally compressed and<br />

transferred to the SD/multimedia card or USB flash drive<br />

(optional)<br />

- Automatic transfer detection (Remote Transfer)<br />

- Simulation of the configuration direct on the configuring <strong>PC</strong><br />

- Import/export of all texts including alarms in CSV format for<br />

compiling using standard word processing programs<br />

- Project-specific faceplates which can be changed centrally<br />

Template<br />

- Creation of screen templates<br />

- Position-independent configuration of background objects


■ Function (continued)<br />

Password system<br />

- User-oriented access protection according to requirements<br />

of specific sectors<br />

- Authentication with user ID and password<br />

- User-group-specific rights<br />

Service functions<br />

(optionally with "WinCC flexible /Sm@rtService")<br />

- E-mail generation<br />

- Remote control of the SIMATIC HMI system based on the<br />

Internet Explorer<br />

- Web server with status HTML pages and control functions<br />

Client/server functions<br />

(optionally with "WinCC flexible /Sm@rtAccess")<br />

- Remote control and monitoring of other SIMATIC HMI<br />

systems<br />

- Plant-wide retrieval of information and archiving of process<br />

data<br />

Configuration<br />

Configuration is carried out with the<br />

SIMATIC WinCC flexible SP1 Standard or Advanced<br />

engineering software (see SIMATIC WinCC flexible HMI<br />

Software/engineering software).<br />

Projects (on previous panels) created using ProTool can be<br />

migrated to WinCC flexible.<br />

Applications/options<br />

WinAC MP software PLC for Multi Panels<br />

WinAC MP option for MP 277 (software PLC similar to<br />

performance class CPU 315)<br />

The I/O can be connected via Profibus DP<br />

Note:<br />

WinCC flexible 2007 or higher and MP 277 hardware with<br />

integrated retentive memory is required for using the<br />

software PLC<br />

WinCC flexible /Sm@rtAccess;<br />

remote control and monitoring as well as communication<br />

between different SIMATIC HMI systems (see HMI software/<br />

Runtime software SIMATIC WinCC flexible/WinCC flexible RT<br />

options)<br />

WinCC flexible /Sm@rtService;<br />

remove maintenance and servicing for machines/plants via<br />

the Internet/intranet (see HMI software/Runtime software<br />

SIMATIC WinCC flexible/WinCC flexible RT options)<br />

WinCC flexible /O<strong>PC</strong> server<br />

Communication with applications (e. g. MES, ERP, or office<br />

applications) of different manufacturers (see HMI software/<br />

Runtime software SIMATIC WinCC flexible/WinCC flexible RT<br />

options)<br />

WinCC flexible /Audit<br />

WinCC flexible /ProAgent<br />

SINUMERIK<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI devices for special requirements<br />

Devices with stainless steel front<br />

■ Integration<br />

SIMATIC MP 277 INOX<br />

The MP 277 can in certain cases be connected simultaneously<br />

(multi-protocol capable) to:<br />

SIMATIC S7-200/-300/-400<br />

SIMATIC WinAC Software/Slot PLC<br />

SIMATIC WinAC MP 2007<br />

SIMATIC S5<br />

SIMATIC 505<br />

http communication with other SIMATIC HMI systems<br />

(optional with "WinCC flexible /Sm@rtAccess" option)<br />

SIMOTION<br />

SINUMERIK<br />

(optionally with "SINUMERIK HMI copy license<br />

WinCC flexible CE"; "SINUMERIK HMI engineering package<br />

WinCC flexible" is additionally required for configuring;<br />

for further details, see <strong>Catalog</strong> NC 60)<br />

O<strong>PC</strong> XML Server<br />

(optionally with "WinCC flexible /O<strong>PC</strong> server")<br />

Third-party controllers<br />

- Allen Bradley<br />

- Mitsubishi<br />

- LG GLOFA GM<br />

- Modicon<br />

- GE-Fanuc<br />

-Omron<br />

- Telemecanique Uni-Telway<br />

Via Ethernet (TCP/IP) to a higher-level <strong>PC</strong>, with enabled<br />

network printer<br />

Note:<br />

Further information can be found under "System interfaces".<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

3/29<br />

3


3<br />

HMI devices for special requirements<br />

Devices with stainless steel front<br />

SIMATIC MP 277 INOX<br />

■ Technical specifications<br />

6AV6 643-0ED01-2AX0<br />

Product type designation<br />

10" color Touch INOX<br />

(with stainless steel front)<br />

Display<br />

Size 10.4"<br />

Display type TFT, 65536 Farben<br />

Resolution (pixels)<br />

Resolution (WxH in pixel) 640 x 4<strong>80</strong><br />

Backlighting<br />

MTBF backlighting (at 25 °C) about 50,000 hours<br />

Control elements<br />

Control elements Touch screen<br />

Connection for mouse/keyboard/ USB / USB / USB<br />

barcode reader<br />

Keyboard<br />

Numeric/alphabetical input Yes / Yes<br />

Touch operation<br />

Touch screen analog, resistive<br />

Supply voltage<br />

Input voltage<br />

permissible range +20.4 V to +28.8 V DC<br />

Supply voltage 24 V DC<br />

Processor<br />

Processor ARM<br />

Memory<br />

Type Flash / RAM<br />

Usable memory for user data 6 MB usable memory for user<br />

data<br />

Time of day<br />

Clock<br />

Type Hardware clock, battery backup,<br />

synchronizable<br />

Interfaces<br />

Interfaces 1 x RS422, 1 x RS485, 1 x<br />

Ethernet (RJ45)<br />

USB port 2 x USB<br />

Multi Media Card slot 1 x Multi Media Card slot<br />

Industrial Ethernet<br />

Industrial Ethernet interface 1 x Ethernet (RJ45)<br />

Ambient conditions<br />

Operating temperature<br />

Operation 0 °C to +50 °C<br />

Storage/transport temperature<br />

Transport, storage -20 °C to +60 °C<br />

Relative humidity<br />

max. relative humidity 90 %<br />

Mounting position vertical<br />

maximum permissible angle of incli- +/- 35 °<br />

nation without external ventilation<br />

Degree and class of protection<br />

Front IP66K, NEMA 4x, (when installed)<br />

Rear IP20<br />

Standards, approvals, certificates<br />

Certifications CE, FM Class I Div. 2, UL, CSA,<br />

cULus, EX-Zone 2, EX-Zone 22,<br />

NEMA 4x (Enclosure Type 4X,<br />

Type 12)<br />

Operating systems<br />

Operating system Windows CE<br />

3/30<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV6 643-0ED01-2AX0<br />

Product type designation<br />

10" color Touch INOX<br />

(with stainless steel front)<br />

Configuration<br />

Configuration software<br />

Configuration tool see "Configuration overview" from<br />

page 2/3<br />

Functionality under<br />

WinCC flexible<br />

Applications/options see chapter 4: HMI software/<br />

SIMATIC WinCC flexible options<br />

and SIMATIC WinCC (TIA portal)<br />

options<br />

Number of Visual Basic Scripts 50<br />

Task planner Yes<br />

Help system Yes<br />

Status/control with SIMATIC S7<br />

With alarm logging system (incl.<br />

buffer and acknowledgment)<br />

Number of messages 4000<br />

Bit messages Yes<br />

Analog messages Yes<br />

Message buffer Ring buffer (n x 512 entries),<br />

retentive, maintenance-free<br />

Recipes<br />

Recipes 300<br />

Data records per recipe 500<br />

Entries per data record 1000<br />

Recipe memory 64 KB integrated Flash,<br />

expandable<br />

Number of process images<br />

Process images 500<br />

Variables 2048<br />

Limit values Yes<br />

Multiplexing Yes<br />

Image elements<br />

Text objects 10,000 text elements<br />

Graphics object Bit maps, icons, vector graphics<br />

dynamic objects Diagrams, bar graphs, sliders,<br />

analog display, invisible buttons<br />

Lists<br />

Text lists 500<br />

Graphics list 400<br />

Libraries Yes<br />

Archiving<br />

Number of archives per project 20<br />

Number of measuring points per 20<br />

project<br />

Number of entries per archive 10 000<br />

Memory location SD and Multi Media Card<br />

Security<br />

Number of user groups 50<br />

Passwords exportable Yes<br />

Number of user rights 32<br />

Data carrier support<br />

Multimedia Card Yes<br />

Recording<br />

Recording/Printing Alarms, report (shift report),<br />

color print, hardcopy<br />

Fonts<br />

Keyboard fonts US American (English)


■ Technical specifications (continued)<br />

Product type designation<br />

Languages<br />

Configuration languages D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified", DK, FIN, GR, J,<br />

KP / ROK, NL, N, PL, P, RUS, S,<br />

CZ / SK, TR, H<br />

Character sets Tahoma, Arial, Courier New,<br />

WinCC flexible Standard, symbol<br />

languages, all freely scalable<br />

Transfer (upload/download)<br />

Transfer of configuration MPI/PROFIBUS DP, USB,<br />

Ethernet, automatic transfer<br />

recognition<br />

Process coupling<br />

Connection to controller see "System interfaces" from<br />

page 2/179<br />

Expandability/openness<br />

Open Platform Program Yes<br />

I/O<br />

I/O devices Printer, barcode reader<br />

Dimensions and weight<br />

Dimensions<br />

Front of enclosure (W x H) 325 mm x 263 mm<br />

Mounting cutout/device depth (W<br />

x H<br />

Weight<br />

Weight 4.2 kg<br />

6AV6 643-0ED01-2AX0<br />

10" color Touch INOX<br />

(with stainless steel front)<br />

310 mm x 248 mm / 61 mm<br />

device depth<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI devices for special requirements<br />

Devices with stainless steel front<br />

■ Ordering data Order No.<br />

SIMATIC MP 277 INOX<br />

Multi Panel (including installation<br />

accessories) with<br />

10" color TFT display, Touch,<br />

INOX (with stainless steel front<br />

panel)<br />

Configuration<br />

1) Can only be used for license handling<br />

SIMATIC MP 277 INOX<br />

E 6AV6 643-0ED01-2AX0<br />

with SIMATIC WinCC flexible see HMI software<br />

Configuration set<br />

Consisting of:<br />

WinCC flexible Standard<br />

engineering software<br />

Documentation DVD, 5<br />

languages (English, French,<br />

German, Italian, Spanish)<br />

RS232 cable (5m)<br />

MPI cable, 5 m<br />

Applications/options<br />

D 6AV6 622-0BA01-0AA0<br />

For configuration with<br />

WinCC flexible<br />

WinCC flexible /Sm@rtAccess<br />

WinCC flexible /Sm@rtService<br />

WinCC flexible /O<strong>PC</strong> server<br />

WinCC flexible /ProAgent<br />

WinCC flexible /Audit<br />

WinAC MP 2007 / software PLC<br />

Documentation<br />

(to be ordered separately)<br />

MP 277 Operating Instructions<br />

see HMI software<br />

German 6AV6 691-1DJ01-0AA0<br />

English 6AV6 691-1DJ01-0AB0<br />

French 6AV6 691-1DJ01-0AC0<br />

Italian 6AV6 691-1DJ01-0AD0<br />

Spanish<br />

WinCC flexible Compact/<br />

Standard/Advanced User Manual<br />

6AV6 691-1DJ01-0AE0<br />

German 6AV6 691-1AB01-3AA0<br />

English 6AV6 691-1AB01-3AB0<br />

French 6AV6 691-1AB01-3AC0<br />

Italian 6AV6 691-1AB01-3AD0<br />

Spanish<br />

User Manual<br />

WinCC flexible Communication<br />

6AV6 691-1AB01-3AE0<br />

German 6AV6 691-1CA01-3AA0<br />

English 6AV6 691-1CA01-3AB0<br />

French 6AV6 691-1CA01-3AC0<br />

Italian 6AV6 691-1CA01-3AD0<br />

Spanish 6AV6 691-1CA01-3AE0<br />

SIMATIC HMI Manual Collection B 6AV6 691-1SA01-0AX0<br />

Electronic documentation, on DVD<br />

5 languages (English, French,<br />

German, Italian and Spanish);<br />

contains: all currently available<br />

user manuals, manuals and<br />

communication manuals for<br />

SIMATIC HMI<br />

Accessories see HMI accessories<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

3/31<br />

3


3<br />

HMI devices for special requirements<br />

Devices with stainless steel front<br />

SIMATIC MP 277 INOX<br />

■ Dimensional drawings<br />

All dimensions in mm. Tolerance ± 1 mm.<br />

Panel cutout see technical specifications.<br />

275<br />

MP 277 10" Touch with stainless steel front<br />

3/32<br />

SIEMENS<br />

335<br />

SIMATIC MULTI PANEL<br />

309<br />

260 20<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

160<br />

247<br />

43<br />

61 6<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00285<br />

■ More information<br />

Additional information is available on the Internet under:<br />

www.siemens.com/inox-hmi-devices<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.


■ Overview<br />

Like operator panels, Multi Panels (MP) are used for local<br />

machine operation and monitoring<br />

Their functionality can be expanded by installing additional<br />

Windows CE applications (Multi Panel and Panel options)<br />

SIMATIC MP 377 INOX devices on the basis of Windows CE<br />

combine the rugged construction of Operator Panels with the<br />

flexibility of <strong>PC</strong>s<br />

PLC functionality can be integrated directly into the MP 377<br />

platform with Option<br />

Pixel graphics 15" TFT display, color (64k colors)<br />

Touch screen (analog/resistive)<br />

The MP 377 INOX is available with a stainless steel front<br />

(EN 1672-2). These versions expand the application area of<br />

the Multi Panel 377 for special applications, ambient<br />

conditions, and special sectors (e. g. food, beverages and<br />

tobacco industries).<br />

All interfaces, e. g. MPI, PROFIBUS DP, USB, PROFINET<br />

(Ethernet TCP/IP) are on-board<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI devices for special requirements<br />

Devices with stainless steel front<br />

■ Benefits<br />

SIMATIC MP 377 INOX<br />

Integral component of Totally Integrated Automation (TIA):<br />

Increase of productivity, minimization of engineering<br />

overhead, reduction of lifecycle costs<br />

Modular expansion capability with options such as:<br />

- Software PLC SIMATIC WinAC MP<br />

- WinCC flexible /Sm@rtAccess for communication between<br />

different SIMATIC HMI systems<br />

- WinCC flexible /Sm@rtService for remote maintenance and<br />

servicing of machines/plants via the Internet/intranet<br />

- WinCC flexible /O<strong>PC</strong> server for communication with<br />

applications from different manufacturers<br />

- MS Pocket Internet Explorer 6.0 (included in scope of<br />

delivery)<br />

- MS Multi Media Player (included in scope of delivery)<br />

- MS Viewer for Word, Excel and PDF files (already included in<br />

scope of delivery)<br />

Reduction of service and commissioning costs due to:<br />

- Backup/restore via Ethernet (TCP/IP), USB, MPI,<br />

PROFIBUS DP or optionally via CF/SD/Multimedia Card<br />

- Remote download/upload of the configuration and firmware<br />

- Specific drivers can be reloaded<br />

- Long service life of the backlit display<br />

Graphic library with preconfigured screen objects<br />

Can be used worldwide:<br />

- 32 online languages (incl. Asian and Cyrillic character sets)<br />

can be configured<br />

- Up to 16 languages can be selected online<br />

Standard hardware and software interfaces for increasing<br />

flexibility:<br />

- CF Card slot and SD/Multimedia Card slot for language<br />

expansions, backup/restore<br />

- Ethernet (TCP/IP) for central data and project administration,<br />

and control interfacing to SIMATIC S7 possible<br />

- Standard Windows storage formats (CSV) for archives and<br />

recipes permits further processing using standard tools<br />

(e.g. MS Excel)<br />

■ Application<br />

The Multi Panels SIMATIC MP 377 INOX can be used wherever<br />

machines and systems are operated and monitored directly<br />

on-site – whether in production, process or building automation.<br />

These are used in the most popular branches and applications<br />

and can be expanded in their applications with the Multi Panel<br />

options, e. g. by displaying HTML documents via the Microsoft<br />

Pocket Internet Explorer.<br />

Windows CE meets the basic prerequisites for application in<br />

rough industrial environments. The diskless and fanless design<br />

enables implementation in areas where high vibration or dust<br />

load limits the operation of a <strong>PC</strong>. Short boot-up times make the<br />

Multi Panels ready for operation sooner as well.<br />

The Multi Panel 15" Touch with stainless steel front is designed<br />

for all industries that require such a front. The front can be disinfected<br />

and does not affect the quality e. g. of foods (assuming<br />

regular cleaning). Cleaning can be carried out using<br />

pressurized water with a jet of 100 l/min at 1 bar from a distance<br />

of 2.5 to 3 m. Liquids flow off automatically from the front panels.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

3/33<br />

3


3<br />

HMI devices for special requirements<br />

Devices with stainless steel front<br />

SIMATIC MP 377 INOX<br />

■ Design<br />

Compact design with low mounting depth<br />

The front is resistant to various oils, greases and standard<br />

detergents<br />

Degree of protection IP66K/NEMA 4x/NEMA 12 (front) or IP20<br />

(rear)<br />

Plug-in terminals for 24 V DC power supply<br />

Interfaces:<br />

RS 485/RS 422 interface for process connections (MPI,<br />

PROFIBUS DP up to 12 Mbit/s)<br />

USB for mouse, keyboard, printer, barcode reader, and<br />

downloading/uploading the configuration<br />

Ethernet (TCP/IP) for exchanging data with a higher-level <strong>PC</strong>,<br />

connection of a network printer and downloading/uploading<br />

the configuration; a control link to SIMATIC S7 is possible<br />

Slot for CompactFlash card (CF card)<br />

Slot for SD/multimedia card<br />

Retentive memory for WinAC MP 377 data (data, timers,<br />

counters and bit memories)<br />

■ Function<br />

Display and changing of process parameters<br />

Process display:<br />

- Vector graphic (various line and plane objects)<br />

- Dynamic positioning and dynamic showing/hiding of objects<br />

- Fully-graphical displays, plots, and bar graph display<br />

- Display of up to 8 trends per trend field;<br />

trend curve graphic with scroll and zoom functions for<br />

accessing the history and flexible selection of the<br />

representation period;<br />

read ruler for determining current values and display in a<br />

table<br />

- Comprehensive graphic libraries (SIMATIC HMI Symbol<br />

Library)<br />

- Icons: slider, gauge, clock<br />

- Cyclic function processing by alarm clock<br />

Multiplex function for variables<br />

Signaling system<br />

- Discrete alarms and analog messages (limit value<br />

messages) as well as the Alarm S message frame procedure<br />

for SIMATIC S7 and SIMOTION<br />

- Freely-definable message classes (e.g. status/fault<br />

messages) for definition of acknowledgment response and<br />

display of message events<br />

- Status and fault messages with message history<br />

- Preconfigured message screen, message window, and<br />

message line<br />

Archiving of messages and process values (on CF/SD/<br />

multimedia card/USB flash drive, etc. or network drives via<br />

Ethernet)<br />

- Various archive types: Circulating and sequence archive<br />

- Storage of archive data in standard Windows format (CSV)<br />

- Online evaluation of process value archives using trend<br />

curves<br />

- External evaluation using standard tools (MS Excel,<br />

MS Access) is possible<br />

Alarm log and shift log<br />

Print functions (see "Recommended printers")<br />

Language switching<br />

16 online languages, 32 configuring languages, incl. Asian<br />

and Cyrillic character sets<br />

3/34<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Recipe management<br />

- With additional data storage (on CF/SD/Multimedia Card/<br />

USB flash drive, etc.)<br />

- Online/offline processing on the panel<br />

- Storage of recipe data in standard Windows format (CSV)<br />

- External processing using standard tools (MS Excel,<br />

MS Access) is possible<br />

PG functionality <strong>ST</strong>ATUS FORCE-VAR in combination with<br />

SIMATIC S5 and SIMATIC S7<br />

Screen selection from PLC<br />

permits operator control from the PLC<br />

Display of HTML documents using MS Pocket Internet<br />

Explorer<br />

Visual Basic Script, flexibility through implementing new<br />

functions incl. interfacing to variables (comparison<br />

operations, loop-through, etc.)<br />

Help texts<br />

for process pictures, alarms, and tags<br />

Arithmetic functions<br />

Limit value monitoring<br />

for reliable process control of inputs and outputs<br />

Permanent window<br />

- Fixed screen area for output of screen-independent<br />

information (e.g. important process variables, data, and<br />

time-of-day)<br />

- Permanent window expanded with templates concept for<br />

creating screen models<br />

Facilitates service and configuration due to<br />

- Backup and restoring of configuration, operating system,<br />

data records, and firmware on an optional memory card<br />

(CF/SD/Multimedia Card) or via Ethernet<br />

- Backup and restoring of configuration, operating system,<br />

data records, and firmware on a <strong>PC</strong><br />

- Download/upload of configuration via Ethernet/USB/MPI/<br />

PROFIBUS DP/modem and CF or SD/Multimedia Card<br />

- Automatic transfer detection<br />

- Configuration simulation directly on the configuration<br />

computer<br />

Import/export of all texts including alarms in CSV format for<br />

compiling using standard word processing programs<br />

Project-specific faceplates which can be changed centrally<br />

User administration (security)<br />

- User-oriented access protection according to requirements<br />

of specific sectors<br />

- Authentication with user ID and password<br />

- User-group-specific rights<br />

Visual Basic Runtime object model<br />

Service functions<br />

(optionally with "WinCC flexible /Sm@rtService")<br />

- E-mail generation<br />

- Remote control of the SIMATIC HMI system based on the<br />

Internet Explorer<br />

- Web server with status HTML pages and control functions<br />

Client/server functions<br />

(optionally with "WinCC flexible /Sm@rtAccess")<br />

- Remote control and monitoring of other SIMATIC HMI<br />

systems<br />

- Plant-wide retrieval of information and archiving of process<br />

data


■ Integration<br />

The MP 377 can be connected to:<br />

SIMATIC S7-200/-300/-400<br />

SIMATIC WinAC Software/Slot PLC<br />

Ethernet communication with SIMATIC S7<br />

SIMATIC S5<br />

SIMATIC 505<br />

SINUMERIK<br />

SIMOTION<br />

Non-<strong>Siemens</strong> controllers:<br />

- Allen Bradley<br />

- Mitsubishi<br />

- Telemecanique<br />

- LG GLOFA GM<br />

- Modicon<br />

- GE-Fanuc<br />

-Omron<br />

Over Ethernet (TCP/IP) to a higher-level <strong>PC</strong>, network printer<br />

Multi-protocol capability<br />

O<strong>PC</strong> XML server (optional with "WinCC flexible /O<strong>PC</strong> server")<br />

http communication with other SIMATIC HMI systems (optional<br />

with "WinCC flexible /Sm@rtAccess")<br />

SINUMERIK<br />

(optionally with "SINUMERIK HMI copy license<br />

WinCC flexible CE"; "SINUMERIK HMI engineering package<br />

WinCC flexible" is additionally required for configuration)<br />

Note:<br />

For further information, see "System interfaces"<br />

■ Configuration<br />

Configuration is implemented using the SIMATIC WinCC flexible<br />

Standard or Advanced engineering software (see HMI software/<br />

SIMATIC WinCC flexible engineering software).<br />

Projects created using ProTool can be migrated to<br />

WinCC flexible.<br />

Applications/options<br />

WinCC flexible /ProAgent<br />

Precise and rapid process fault diagnostics in plants and<br />

machines for SIMATIC S7 and SIMATIC HMI<br />

(see HMI software/SIMATIC ProAgent process fault<br />

diagnostics software)<br />

WinAC MP software PLC for Multi Panels<br />

I/O can be connected via Profibus DP.<br />

WinCC flexible /Sm@rtAccess;<br />

remote control and monitoring as well as communication<br />

between different SIMATIC HMI systems (see HMI software/<br />

Runtime software SIMATIC WinCC flexible/<br />

WinCC flexible RT options)<br />

WinCC flexible /Sm@rtService;<br />

remove maintenance and servicing for machines/plants via<br />

the Internet/intranet (see HMI software/Runtime software<br />

SIMATIC WinCC flexible/WinCC flexible RT options)<br />

WinCC flexible /O<strong>PC</strong> server<br />

Communication with applications (e. g. MES, ERP, or office<br />

applications) of different manufacturers (see HMI software/<br />

Runtime software SIMATIC WinCC flexible/<br />

WinCC flexible RT options)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI devices for special requirements<br />

Devices with stainless steel front<br />

■ Technical specifications<br />

SIMATIC MP 377 INOX<br />

6AV6 644-0CB01-2AX0<br />

Display<br />

Size 15" (304.1 mm x 228.1 mm)<br />

Display type TFT, 65536 Farben<br />

Resolution (pixels)<br />

Resolution (WxH in pixel) 1024 x 768<br />

Backlighting<br />

MTBF backlighting (at 25 °C) about 50,000 hours<br />

Control elements<br />

Control elements Touch screen<br />

Connection for mouse/keyboard/ USB / USB / USB<br />

barcode reader<br />

Keyboard<br />

Numeric/alphabetical input Yes / Yes<br />

Touch operation<br />

Touch screen analog, resistive<br />

Supply voltage<br />

Input voltage<br />

permissible range +19.2 V to +28.8 V DC<br />

Supply voltage 24 V DC<br />

Input current<br />

Rated current 1.7 A; Typical<br />

Memory<br />

Type Flash / RAM<br />

Usable memory for user data 12288 KB usable memory for user<br />

data / 12288 KB additional<br />

memory for options<br />

Type of output<br />

Acoustics WAV sound signal<br />

Time of day<br />

Clock<br />

Type Hardware clock, battery backup,<br />

synchronizable<br />

Interfaces<br />

USB port 2 x USB<br />

<strong>PC</strong> card slot No<br />

CF card slot 1 x CF card slot<br />

Multi Media Card slot 1 x Multi Media Card slot<br />

Industrial Ethernet<br />

Industrial Ethernet interface 2 x Ethernet (RJ45)<br />

Protocols<br />

Protocols (terminal link)<br />

Sm@rtAccess Yes<br />

EMC<br />

Emission of radio interference acc.<br />

to EN 55 011<br />

Emission of radio interferences Yes<br />

acc. to EN 55 011 (limit class A)<br />

Ambient conditions<br />

Operating temperature<br />

Operation (vertical installation) 0 °C to +50 °C<br />

Operation (max. tilt angle) 0 °C to +35 °C<br />

Storage/transport temperature<br />

Transport, storage -20 °C to +60 °C<br />

Relative humidity<br />

max. relative humidity 90 %<br />

maximum permissible angle of incli- +/- 35 °<br />

nation without external ventilation<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

3/35<br />

3


3<br />

HMI devices for special requirements<br />

Devices with stainless steel front<br />

SIMATIC MP 377 INOX<br />

■ Technical specifications (continued)<br />

Degree and class of protection<br />

Front IP66K<br />

Rear<br />

Standards, approvals, certificates<br />

IP20<br />

Certifications<br />

Operating systems<br />

CE, FM Class I Div. 2, UL, cULus,<br />

EX Zone 2, EX Zone 22, C-TICK<br />

Operating system<br />

Configuration<br />

Configuration software<br />

Windows CE<br />

Configuration tool<br />

Functionality under<br />

WinCC flexible<br />

see "configuration overview" from<br />

page 2/3<br />

Applications/options see chapter 4: HMI software/<br />

SIMATIC WinCC flexible options<br />

and SIMATIC WinCC (TIA portal)<br />

options<br />

Number of Visual Basic Scripts 100<br />

Task planner Yes<br />

Help system Yes<br />

Status/control<br />

With alarm logging system (incl.<br />

buffer and acknowledgment)<br />

with SIMATIC S7<br />

Number of messages 4000<br />

Bit messages Yes<br />

Analog messages Yes<br />

Message buffer<br />

Recipes<br />

Ring buffer (n x 1024 entries),<br />

retentive, maintenance-free<br />

Recipes 500<br />

Data records per recipe 1000<br />

Entries per data record 1000<br />

Recipe memory<br />

Number of process images<br />

128 KB integrated Flash,<br />

expandable<br />

Process images 500<br />

Variables 2048<br />

Limit values Yes<br />

Multiplexing<br />

Image elements<br />

Yes<br />

Text objects 30,000 text elements<br />

Graphics object Bit maps, icons, vector graphics<br />

dynamic objects<br />

Lists<br />

Diagrams, bar graphs, sliders,<br />

analog display, invisible buttons<br />

Text lists 500<br />

Graphics list 500<br />

Libraries<br />

Archiving<br />

Yes<br />

Number of archives per project 50<br />

Number of measuring points per<br />

project<br />

50<br />

Number of entries per archive 50 000<br />

Archiving types Yes<br />

Memory location Yes<br />

Data storage format Yes<br />

external evaluation Yes<br />

Size of archive Yes<br />

Online evaluation Yes<br />

3/36<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6AV6 644-0CB01-2AX0<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV6 644-0CB01-2AX0<br />

Security<br />

Number of user groups 50<br />

Passwords exportable Yes<br />

Number of user rights 32<br />

Data carrier support<br />

<strong>PC</strong> card No<br />

CF card Yes<br />

Multimedia Card Yes<br />

Recording<br />

Recording/Printing Alarms, report (shift report),<br />

color print, hardcopy<br />

Printer driver ESC/P2, <strong>PC</strong>L3/<strong>PC</strong>L6<br />

Fonts<br />

Keyboard fonts US American (English)<br />

Languages<br />

Configuration languages D, GB, F, I, E, CHN "traditional",<br />

CHN "simplified", DK, FIN, GR, J,<br />

KP / ROK, NL, N, PL, P, RUS, S,<br />

CZ / SK, TR, H<br />

Character sets Tahoma, Arial, Courier New,<br />

symbol languages, 4 additional<br />

character sets can be loaded, all<br />

freely scalable<br />

Transfer (upload/download)<br />

Transfer of configuration MPI/PROFIBUS DP, serial, USB,<br />

Ethernet, by means of external<br />

storage medium, automatic<br />

transfer recognition<br />

Process coupling<br />

Connection to controller see "System interfaces" from<br />

page 2/179<br />

Expandability/openness<br />

Open Platform Program Yes<br />

I/O<br />

I/O devices Printer, card reader, barcode<br />

reader<br />

Dimensions and weight<br />

Dimensions<br />

Front of enclosure (W x H) 400 mm x 310 mm<br />

Mounting cutout/device depth<br />

(W x H<br />

Weight<br />

Weight 6.2 kg<br />

368 mm x 290 mm/75 mm device<br />

depth


■ Ordering data<br />

SIMATIC MP 377 INOX<br />

Multi Panel (incl. installation<br />

accessories) with<br />

Order No.<br />

15" color TFT display, Touch,<br />

INOX (with stainless steel front)<br />

Configuration<br />

with SIMATIC WinCC flexible<br />

E 6AV6 644-0CB01-2AX0<br />

Configuration set MP 377<br />

Consisting of:<br />

WinCC flexible Standard<br />

engineering software<br />

Documentation DVD,<br />

5 languages (English, French,<br />

German, Italian, Spanish)<br />

RS 232 cable (5 m)<br />

MPI cable, 5 m (for download<br />

and test purposes only)<br />

Applications/options<br />

D 6AV6 622-0BA01-0AA0<br />

For configuration with<br />

WinCC flexible<br />

WinCC flexible /ProAgent<br />

WinCC flexible /Sm@rtAccess<br />

WinCC flexible /Sm@rtService<br />

WinCC flexible /O<strong>PC</strong> server<br />

WinCC flexible /Audit<br />

WinAC MP 2007 / software PLC<br />

Documentation<br />

(to be ordered separately)<br />

MP 377 Operating Instructions<br />

see HMI software<br />

German 6AV6 691-1DR01-0AA0<br />

English 6AV6 691-1DR01-0AB0<br />

French 6AV6 691-1DR01-0AC0<br />

Italian 6AV6 691-1DR01-0AD0<br />

Spanish<br />

WinCC flexible Compact/<br />

Standard/Advanced User<br />

Manual<br />

6AV6 691-1DR01-0AE0<br />

German 6AV6 691-1AB01-3AA0<br />

English 6AV6 691-1AB01-3AB0<br />

French 6AV6 691-1AB01-3AC0<br />

Italian 6AV6 691-1AB01-3AD0<br />

Spanish<br />

User Manual<br />

WinCC flexible Communication<br />

6AV6 691-1AB01-3AE0<br />

German 6AV6 691-1CA01-3AA0<br />

English 6AV6 691-1CA01-3AB0<br />

French 6AV6 691-1CA01-3AC0<br />

Italian 6AV6 691-1CA01-3AD0<br />

Spanish 6AV6 691-1CA01-3AE0<br />

SIMATIC HMI Manual Collection B<br />

Electronic documentation,<br />

on DVD<br />

5 languages (English, French,<br />

German, Italian and Spanish);<br />

contains: all currently available<br />

user manuals, manuals and<br />

communication manuals for<br />

SIMATIC HMI<br />

6AV6 691-1SA01-0AX0<br />

Accessories for supplementary<br />

ordering<br />

see HMI accessories<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

1) Can only be used for license handling<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI devices for special requirements<br />

Devices with stainless steel front<br />

■ Dimensional drawings<br />

All specifications in mm.<br />

Panel cutout see technical specifications.<br />

310<br />

35<br />

400<br />

366<br />

295<br />

SIMATIC MP 377 15" Touch with stainless steel front<br />

SIMATIC MP 377 INOX<br />

73 38<br />

288<br />

■ More information<br />

Additional information is available in the Internet under:<br />

www.siemens.com/inox-hmi-devices<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

30<br />

75<br />

6<br />

G_<strong>ST</strong><strong>80</strong>_XX_00311<br />

3/37<br />

3


3<br />

HMI devices for special requirements<br />

Devices with stainless steel front<br />

SIMATIC Panel <strong>PC</strong> 677B INOX<br />

■ Overview<br />

<strong>PC</strong> platform with high degree of industrial compatibility for<br />

demanding tasks in the area of <strong>PC</strong>-based automation.<br />

Rugged construction:<br />

The <strong>PC</strong> is resistant to the harshest mechanical stress and is<br />

reliable in operation.<br />

Compact design<br />

High degree of investment protection<br />

Fast integration capability<br />

Front panel versions:<br />

- 15" TFT Touch, stainless steel/INOX<br />

The operator control unit and computing unit can be placed<br />

30 m apart (optional).<br />

3/38<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

High industrial compatibility due to rugged design, even if<br />

subjected to strong vibrations and shocks<br />

High degree of investment protection due to guaranteed<br />

availability of spare parts (for 5 years after end of active<br />

marketing)<br />

High degree of continuity of components for long-lasting<br />

machine concepts without new engineering overhead<br />

Time and cost savings due to service-friendly hardware<br />

configuration:<br />

- Operator control unit and computer unit can be opened<br />

easily for fast replacement of components or subsequent<br />

expansions<br />

- USB 2.0 interfaces on the rear for simple and quick<br />

connection of additional hardware components<br />

High degree of industrial functionality thanks to integrated<br />

PROFIBUS DP/MPI or PROFINET (CP1616-compatible) and<br />

2 Gigabit Ethernet interfaces<br />

2 x ≥ 250 GB SATA hard disk system (configured as singledisk<br />

system or RAID1)<br />

Minimization of downtimes due to high system availability<br />

Efficient on-board diagnosis (SIMATIC I<strong>PC</strong> DiagMonitor):<br />

- Solutions for preventive data backup<br />

Integrated component of Totally Integrated Automation (TIA):<br />

- Increase of productivity, minimization of engineering<br />

overhead, reduction of lifecycle costs<br />

- Spatially separated installation of computer unit and<br />

operator control unit possible by means of Remote Kit<br />

(up to 30 m, optional accessory)<br />

■ Application<br />

The SIMATIC Panel <strong>PC</strong> 677B INOX is designed for use direct at<br />

the machine. The small mounting depth of only 121/142 mm<br />

means that it can also be used where space is limited.<br />

The <strong>PC</strong> is used both in manufacturing automation and process<br />

automation, installed in control cabinets and consoles, in<br />

19" cabinets/racks and on swing arms (booms).<br />

The Dual Core CPUs with Intel Core2 Duo technology support<br />

simultaneous high-performance control and visualization.<br />

With <strong>PC</strong>Ie (x4), the new <strong>PC</strong>I express (<strong>PC</strong>Ie) cards (x1 and x4) are<br />

also supported.<br />

The integrated NVRAM (battery-backed) is supported with the<br />

SIMATIC WinAC RTX and DC power supply.<br />

A SIMATIC Panel <strong>PC</strong> is the ideal platform for <strong>PC</strong>-based<br />

automation:<br />

<strong>PC</strong>-based visualization at the machine level on site with<br />

SIMATIC WinCC flexible<br />

Complex solutions with SIMATIC WinCC process visualization<br />

<strong>PC</strong>-based control with SIMATIC WinAC software PLC<br />

<strong>Siemens</strong> offers a complete range of automation components that<br />

perfectly complement each other.<br />

SIMATIC Panel <strong>PC</strong>s can be ordered in combination with<br />

WinCC flexible or WinCC as SIMATIC HMI Packages at a price<br />

advantage (see SIMATIC HMI complete systems).


■ Design<br />

The Panel <strong>PC</strong> 677B INOX comprises a computer unit and an<br />

operator control unit.<br />

Components of the computer unit:<br />

Rugged metal enclosure, resistant to vibrations and shocks,<br />

with high electromagnetic compatibility<br />

Processor:<br />

- Mobile Intel 945G chip set<br />

- Intel Celeron M 440/1.86 GHz or<br />

- Intel Core2 Duo T5500/Dual Core, 1.66 GHz or<br />

- Intel Core2 Duo T7400/Dual Core, 2.16 GHz<br />

Basic main memory configuration: 1 GB<br />

3.5" SATA hard disk: ≥ 160 GB;<br />

the special vibration-absorbing hard disk support ensures<br />

reliable operation even under extreme mechanical stress<br />

Onboard graphics<br />

Interfaces:<br />

- 2 x 10/100/1000 Ethernet<br />

- PROFIBUS DP/MPI on board, floating<br />

- PROFINET (IRT-capable), 3-port, switching-enabled,<br />

CP1616-compatible<br />

- 4 x USB 2.0 connection<br />

- 1 x serial V.24 (9-pin)<br />

Retentive memory:<br />

- 512 KB NVRAM, can be used with WinAC RTX 128 KB<br />

(DC versions)<br />

Free slots for expansions:<br />

- 2 x <strong>PC</strong>I (slots with card retainer)<br />

- 1 x slot for CompactFlash card<br />

Power supply: 110/230 V AC (autorange), 50/60 Hz or 24 V DC<br />

DVI-I interface for connecting a further monitor (DVI or VGA)<br />

or Flat Panel<br />

Optional additional components:<br />

Main memory expansion to 2, 3 or 4 GB<br />

SATA hard disk ≥ 250 GB<br />

Dual hard disk module 2 x ≥ 250 GB SATA as single disk<br />

configuration or RAID1 preconfigured<br />

Internal CF card slot (empty, instead of hard disk and optical<br />

drive; only with Windows XP embedded operating system)<br />

DVD±RW±R combo drive<br />

1 x <strong>PC</strong>Ie x 4 / 1 x <strong>PC</strong>I instead of 2 x <strong>PC</strong>I slots<br />

(with card retainers)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI devices for special requirements<br />

Devices with stainless steel front<br />

SIMATIC Panel <strong>PC</strong> 677B INOX<br />

Components of the operator control unit:<br />

The operator control unit is available in the following version:<br />

15" Touch, stainless steel/INOX<br />

15.1" TFT color display, 1024 x 768 (XGA)<br />

Resistive analog touch screen<br />

Stainless steel front, designed for use in the food, beverage<br />

and tobacco industries<br />

Developed on the basis of EN 1672-2<br />

Polished surface (stainless steel 1.4301, brushed metal finish,<br />

grain 240)<br />

IP66k on the front<br />

Without USB front interface<br />

Shatter-protection for the display<br />

Optimized frame surface to allow liquids to run off<br />

Minimized grooves and gaps<br />

Decorative foil tested against chemicals in accordance with<br />

DIN 42115, Part 2<br />

Mounting with clamping frame only. Sealing material food-safe<br />

(EDPM, in accordance with FDA 21 CFR 177.2006)<br />

Prepared for EHEDG certification for the entire machine<br />

The operator control unit complies with the requirements of<br />

degrees of protection IP66K and NEMA 4.<br />

The computer unit is connected to the rear of the operator<br />

control unit using cables.<br />

Expansion components<br />

SIMATIC I<strong>PC</strong> DiagMonitor<br />

<strong>PC</strong> diagnostics/alarm software for the early detection and<br />

diagnosis of <strong>PC</strong> problems<br />

Comprehensive monitoring of temperature, fans, hard disks<br />

(SMART), watchdog<br />

Operating hours counter for preventive maintenance<br />

Integrated log functions, comprehensive text messages,<br />

online help (English/German)<br />

Network-wide monitoring via SNMP and O<strong>PC</strong> interface<br />

possible<br />

Integrated Web server for monitoring over the network using a<br />

Web browser<br />

SIMATIC I<strong>PC</strong> Image & Partition Creator<br />

Software tool for quick and easy back-up and restoring of the<br />

content of hard disks (images of individual partitions or<br />

complete hard disks) and for simple subsequent modification<br />

of the hard disk partitioning without loss of data.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

3/39<br />

3


3<br />

HMI devices for special requirements<br />

Devices with stainless steel front<br />

SIMATIC Panel <strong>PC</strong> 677B INOX<br />

■ Design (continued)<br />

SIMATIC I<strong>PC</strong> USB FlashDrive<br />

Mobile memory medium for SIMATIC <strong>PC</strong>/PG<br />

Fast data transfer (USB 2.0) and high memory capacity<br />

Ultra-compact and rugged<br />

SIMATIC I<strong>PC</strong> Service USB FlashDrive<br />

Mobile memory medium for backing up/restoring mass<br />

memories<br />

Pre-installed Image & Partition Creator V3.1<br />

Ultra-compact and rugged<br />

SIMATIC Panel <strong>PC</strong> Remote Kit<br />

Spatially separated configuration of computer and operator<br />

control unit<br />

At a maximum distance of up to 30 m<br />

Pure hardware solution, no need to install additional software<br />

Maintaining the Panel <strong>PC</strong> front functionality<br />

Additional USB interface on the rear<br />

Centralized and distributed configuration with only one basic<br />

unit<br />

Can be retrofitted<br />

3/40<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Industrial USB Hub 4<br />

USB I/O can be connected and operated without opening the<br />

control cabinet door using the Industrial Hub 4.<br />

Industry-standard USB 2.0 hub, front IP65<br />

Mounting in control cabinet door or on DIN rail<br />

Inspection window and LEDs for each of the four interfaces<br />

Note:<br />

For further information, see "Expansion components".


■ Function<br />

Integrated, parameterizable monitoring functions (program<br />

execution (watchdog), temperature inside enclosure, fan<br />

speed)<br />

Expanded diagnostics/messages via Ethernet, e-mail, text<br />

message and for direct transfer to SIMATIC software via O<strong>PC</strong><br />

(optionally via SIMATIC I<strong>PC</strong> DiagMonitor)<br />

RAID1 for automatic data mirroring on two SATA hard disks<br />

■ Integration<br />

Integrated interfaces<br />

Ethernet<br />

The integrated Ethernet interfaces (10/100/1000 Mbit/s) can<br />

be used for IT communication and for exchanging data with<br />

programmable controllers such as SIMATIC S7 (with the<br />

"SOFTNET S7" software packages).<br />

PROFIBUS<br />

The floating PROFIBUS interface (12 Mbit/s) can be used for<br />

connecting distributed field devices or for coupling to<br />

SIMATIC S7 (with the software package "SOFTNET for<br />

PROFIBUS").<br />

PROFINET<br />

The three (IRT-capable) PROFINET ports can be used<br />

to connect distributed I/O, SIMATIC S7, and drives.<br />

The switching-capable ports of the CP1616-compatible<br />

PROFINET option support line and tree topologies<br />

(WinAC RTX Version 2008 or higher). Alternatively, the<br />

interface can be used as standard Windows interface.<br />

Further interfaces<br />

For connecting additional I/O devices, 2 spare slots are<br />

available for <strong>PC</strong>I modules or alternatively 1 x <strong>PC</strong>I and<br />

1 x <strong>PC</strong>Ie x4 modules, as well as a CompactFlash Card<br />

interface, 4 USB 2.0 interfaces (Universal Serial Bus), and<br />

one serial interface.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI devices for special requirements<br />

Devices with stainless steel front<br />

SIMATIC Panel <strong>PC</strong> 677B INOX<br />

■ Technical specifications<br />

6AV7 872-.....-...0<br />

Product type designation SIMATIC Panel <strong>PC</strong> 677B<br />

15" Touch<br />

Operator control and monitoring<br />

Accessory components Touch protective foil<br />

(not for Inox front), remote kit<br />

General features<br />

Front panel 15" TFT Touch<br />

Display<br />

Expansion components Uninterruptible power supply<br />

(USP), SIMATIC NET communication<br />

modules<br />

Power loss in full configuration 140 W max.<br />

(15 W included per slot)<br />

Screen diagonal 15 in<br />

Resolution (WxH in pixel) 1024 x 768<br />

Backlighting<br />

MTBF backlighting (at 25 °C) 50000 h in 24 h permanent<br />

operation, temperaturedependent<br />

Operating mode<br />

Function keys No<br />

Mouse, at front No<br />

Touch operation<br />

Alphanumeric keyboard No<br />

Touch screen (analog/resistive) Yes<br />

Design<br />

central design Yes<br />

distributed design Yes; by means of remote kit<br />

Dimensions<br />

Mounting cutout/device depth 450x290 / 142 (incl. optical drive)<br />

(W x H)<br />

Install. dimensions, centralized 450x290x121<br />

design (W x H x D without optical<br />

drive) in mm<br />

additional mounting depth<br />

21 mm<br />

(optical drive)<br />

Operator control unit (W x H) in mm 483x310 (19", 7 HU)<br />

Install. dimensions, operator panel 450x290x85<br />

with distributed design (W x H x D)<br />

in mm<br />

Install. dimensions, computer unit 298x301x100;<br />

with distributed design (W x H x D) (298x301x<strong>80</strong> without CD)<br />

in mm<br />

Dimensions and weight<br />

Weight<br />

Panel <strong>PC</strong> in central design, 14 kg<br />

approx.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

3/41<br />

3


3<br />

HMI devices for special requirements<br />

Devices with stainless steel front<br />

SIMATIC Panel <strong>PC</strong> 677B INOX<br />

■ Ordering data Order No. Order No.<br />

Panel <strong>PC</strong> configurator<br />

(job-oriented production<br />

and delivery)<br />

SIMATIC Panel <strong>PC</strong> 677B INOX<br />

Front options<br />

D 6AV7 87 7 - 7 7 7 7 7 - 7 7 7 0<br />

15" Touch INOX front, without<br />

front USB<br />

Power supply<br />

2 2<br />

24 V DC A<br />

110/230 V AC, power cable for<br />

Europe<br />

B<br />

110/230 V AC (without power<br />

cable)<br />

C<br />

110/230 V AC, power cable for<br />

UK<br />

D<br />

110/230 V AC, power cable for<br />

CH<br />

E<br />

110/230 V AC, power cable for<br />

the USA<br />

F<br />

110/230 V AC, power cable for<br />

Italy<br />

G<br />

110/230 V AC, power cable for<br />

China<br />

Processor<br />

H<br />

Intel Celeron M 440 / 1.86 GHz,<br />

533 MHz FSB, 1 MB SLC, slots<br />

(free): 2 x <strong>PC</strong>I<br />

A<br />

Intel Celeron M 440 / 1.86 GHz,<br />

533 MHz FSB, 1 MB SLC, slots<br />

(free): 1 x <strong>PC</strong>Ie x4 and 1 x <strong>PC</strong>I<br />

B<br />

Intel Core2 Duo T5500 / Dual<br />

Core, 1.66 GHz, 677 MHz FSB,<br />

2 MB SLC, slots (free): 2 x <strong>PC</strong>I<br />

C<br />

Intel Core2 Duo T5500 / Dual<br />

Core, 1.66 GHz, 677 MHz FSB,<br />

2 MB SLC, slots (free):<br />

1 x <strong>PC</strong>Ie x4 and 1 x <strong>PC</strong>I<br />

D<br />

Intel Core2 Duo T7400 / Dual<br />

Core, 2.16 GHz, 677 MHz FSB,<br />

4 MB SLC, slots (free): 2 x <strong>PC</strong>I<br />

E<br />

Intel Core2 Duo T7400 / Dual<br />

Core, 2.16 GHz, 677 MHz FSB,<br />

4 MB SLC, slots (free):<br />

1 x <strong>PC</strong>Ie x4 and 1 x <strong>PC</strong>I<br />

Main memory<br />

F<br />

1 GB DDR2 2<br />

2 GB DDR2 3<br />

3 GB DDR2 4<br />

4 GB DDR2 5<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

1) Multi-Language means: Ger/En/Fr/It/Sp/CHIN traditional/<br />

CHIN simplified/KOR/JAP<br />

2) Not with internal second CF card slot<br />

3) Windows 2000 does not support dual core CPUs; under<br />

Windows 2000, only one core is activated.<br />

4) Only without RAID 1 option<br />

5) Multi-Language means: Ger/En/Fr/It/Sp; other languages only by<br />

downloading from Microsoft<br />

6) Not with Windows 2000 Professional or Windows 2003 Server<br />

7) Only with Core2 Duo CPUs, not with PROFINET option<br />

3/42<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC Panel <strong>PC</strong> 677B INOX<br />

Mass storage<br />

D 6AV7 87 7 - 7 7 7 7 7 - 7 7 7 0<br />

160 GB SATA hard disk 0<br />

250 GB SATA hard disk 1<br />

RAID1 dual hard disk module<br />

2 x 250 GB SATA, preconfigured<br />

2<br />

Dual hard disk module<br />

2 x 250 GB SATA<br />

3<br />

Second CF card slot (only in<br />

combination with Windows XP<br />

embedded), internal, not fitted,<br />

only with version without opt.<br />

drive and without HDD<br />

Optical drives<br />

4<br />

Without 0<br />

DVD±RW±R combo drive<br />

Communication interfaces<br />

1<br />

PROFIBUS/MPI; 2 x Gbit<br />

Ethernet, 512 KB NV-RAM<br />

A<br />

PROFINET (3 x RJ45, CP1616compatible);<br />

2 x Gbit Ethernet,<br />

512 KB NVRAM 6)<br />

Operating system<br />

B<br />

Without operating system 2) A<br />

Windows 2000 Professional<br />

Multi-Language 1) 2) 3)<br />

B<br />

Windows XP Professional<br />

Multi-Language 1) 2)<br />

C<br />

Windows Vista Ultimate Multi-<br />

Language<br />

D<br />

Windows Server 2003 Standard<br />

Edition incl. 5 clients 7) MUI 5) ,<br />

SP1 (SP2 enclosed)<br />

E<br />

Windows XP embedded<br />

(English) 4) Panel <strong>PC</strong> configurator<br />

(job-oriented production<br />

and delivery)<br />

on 2 GB CF card<br />

F


HMI devices for special requirements<br />

Devices with stainless steel front<br />

■ Ordering data Order No. Order No.<br />

Accessories<br />

Memory expansion<br />

1 GB DDR2 A 6ES7 648-2AG40-0HA0<br />

2 GB DDR2<br />

Non-heating apparatus cable<br />

for SIMATIC Box and Panel <strong>PC</strong><br />

SIMATIC <strong>PC</strong> power cable,<br />

230 V AC, angled, 3 m,<br />

for:<br />

A 6ES7 648-2AG50-0HA0<br />

Germany 6ES7 900-1AA00-0XA0<br />

United Kingdom 6ES7 900-1BA00-0XA0<br />

Switzerland 6ES7 900-1CA00-0XA0<br />

USA 6ES7 900-1DA00-0XA0<br />

Italy 6ES7 900-1EA00-0XA0<br />

China 6ES7 900-1FA00-0XA0<br />

Touch pen<br />

Captive pen for operation of the<br />

touch devices, mounting of the<br />

support on the control cabinet<br />

Expansion components<br />

A 6AV7 672-1JB00-0AA0<br />

SIMATIC I<strong>PC</strong> DiagMonitor V4.2<br />

Software tool for monitoring<br />

SIMATIC I<strong>PC</strong>s, incl. manual,<br />

on CD-ROM (German/English)<br />

B 6ES7 648-6CA04-2YX0<br />

SIMATIC I<strong>PC</strong> Image & Partition D<br />

Creator V3.1<br />

Software tool for preventive data<br />

backup and hard disk partitioning<br />

for SIMATIC I<strong>PC</strong>s, incl. manual on<br />

CD-ROM (German, English)<br />

6ES7 648-6AA03-1YA0<br />

SIMATIC I<strong>PC</strong> USB FlashDrive<br />

8 GB, USB 2.0; metal enclosure,<br />

bootable<br />

A 6ES7 648-0DC50-0AA0<br />

SIMATIC I<strong>PC</strong> Service<br />

USB FlashDrive<br />

8 GB, USB 2.0, metal enclosure,<br />

bootable, Image & Partition<br />

Creator pre-installed, incl. CD<br />

B 6AV7 672-8JD01-0AA0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC Panel <strong>PC</strong> 677B INOX<br />

Expansion components<br />

(continued)<br />

SIMATIC Panel <strong>PC</strong> Remote Kit<br />

for the separate configuration of<br />

control unit and <strong>PC</strong><br />

24 V DC, 5 m A 6AV7 671-1EA00-5AA1<br />

24 V DC, 10 m A 6AV7 671-1EA01-0AA1<br />

24 V DC, 15 m A 6AV7 671-1EA01-5AA1<br />

24 V DC, 20 m A 6AV7 671-1EA02-0AA1<br />

24 V DC, 30 m A 6AV7 671-1EA03-0AA1<br />

110/230 V AC, 5 m A 6AV7 671-1EA10-5AA1<br />

110/230 V AC, 10 m A 6AV7 671-1EA11-0AA1<br />

110/230 V AC, 15 m A 6AV7 671-1EA11-5AA1<br />

110/230 V AC, 20 m A 6AV7 671-1EA12-0AA1<br />

110/230 V AC, 30 m A 6AV7 671-1EA13-0AA1<br />

Industrial USB Hub 4<br />

4 x USB 2.0 interfaces, IP65 for<br />

mounting on control cabinet door<br />

or DIN rail<br />

Uninterruptible power supplies<br />

A 6AV6 671-3AH00-0AX0<br />

SITOP power, 15 A DC UPS<br />

module with USB interface<br />

with charger unit for 24 V lead<br />

battery,<br />

input 24 V DC 16 A,<br />

output 24 V DC 15 A<br />

6EP1 931-2EC42<br />

SITOP power, battery module<br />

24 V 3.2 Ah<br />

for DC UPS module 15 A<br />

Communication components<br />

<strong>PC</strong>I interface card<br />

6EP1 935-6MD11<br />

With COM1, COM2 and LPT<br />

interfaces<br />

A 6ES7 648-2CA01-0AA0<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

3/43<br />

3


3<br />

HMI devices for special requirements<br />

Devices with stainless steel front<br />

SIMATIC Panel <strong>PC</strong> 677B INOX<br />

■ Dimensional drawings<br />

All specifications in mm.<br />

Panel cutout see technical specifications.<br />

G<br />

SIMATIC Panel <strong>PC</strong> 677B INOX 15" Touch<br />

Control units<br />

<strong>PC</strong> 677 INOX<br />

Touch devices<br />

G H J K L M N<br />

15" 289 271 138 11 24 367 42<br />

3/44<br />

H<br />

J<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

K<br />

K<br />

L<br />

N<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

M<br />

G_<strong>ST</strong><strong>80</strong>_XX_00288<br />

■ More information<br />

Additional information is available in the Internet under:<br />

www.siemens.com/inox-hmi-devices<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.


■ Overview<br />

<strong>PC</strong> platform with high degree of industrial compatibility for<br />

demanding tasks in the area of <strong>PC</strong>-based automation.<br />

Rugged design:<br />

The <strong>PC</strong> is resistant to the harshest mechanical stress and is<br />

reliable in operation.<br />

Compact design<br />

High degree of investment protection<br />

Fast integration capability<br />

Front panel versions:<br />

- 15" TFT Touch, stainless steel/INOX<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI devices for special requirements<br />

Devices with stainless steel front<br />

■ Benefits<br />

SIMATIC HMI I<strong>PC</strong>677C INOX<br />

High industrial compatibility due to rugged design, even with<br />

high vibration and shock loads<br />

High safeguarding of investments as result of guaranteed<br />

availability of spare parts (further 5 years following end of<br />

active marketing)<br />

High degree of continuity of components for long-lasting<br />

machine concepts without new engineering overhead<br />

Saving of time and costs due to service-friendly device<br />

design:<br />

- Operator control unit and computer unit can be opened<br />

easily for fast replacement of components or subsequent<br />

expansions<br />

- USB 2.0 interfaces at rear for simple and fast connection of<br />

additional hardware components<br />

High degree of industrial functionality thanks to integrated<br />

PROFIBUS DP/MPI or PROFINET (CP1616-compatible) and<br />

2 Gigabit Ethernet interfaces<br />

2 x 250 GB SATA hard disk system (configured as single-disk<br />

system or RAID1)<br />

Minimization of downtimes thanks to high system availability<br />

Efficient self-diagnostics (SIMATIC I<strong>PC</strong> DiagMonitor):<br />

- Solutions for preventive data backup<br />

Integral component of Totally Integrated Automation (TIA):<br />

- Increase in productivity, minimization of engineering<br />

overhead, reduction in lifecycle costs<br />

■ Application<br />

The SIMATIC HMI I<strong>PC</strong> 677C INOX is designed for use directly<br />

on site on the machine. The small mounting depth of only<br />

121/142 mm means that it can also be used where space is<br />

limited.<br />

The <strong>PC</strong> is used both in manufacturing automation and process<br />

automation, installed in control cabinets and consoles,<br />

19" cabinets/racks and swing arms (booms).<br />

Thanks to the Dual Core CPUs with Intel Core technology,<br />

high-performance control and visualization are possible simultaneously.<br />

With <strong>PC</strong>Ie (x16), the new <strong>PC</strong>I express (<strong>PC</strong>Ie) cards<br />

(x1, x4 and x8) are also supported.<br />

The integrated NVRAM (battery-backed) is supported by<br />

WinAC RTX, for device versions with integrated PROFIBUS or<br />

PROFINET (IRT-capable) interfaces.<br />

A SIMATIC Panel <strong>PC</strong> is the ideal platform for <strong>PC</strong>-based<br />

automation:<br />

<strong>PC</strong>-based visualization on site on the machine with<br />

SIMATIC WinCC flexible<br />

Complex solutions with SIMATIC WinCC process visualization<br />

<strong>PC</strong>-based control with SIMATIC WinAC software PLC<br />

<strong>Siemens</strong> offers a complete modular system of perfectly matched<br />

automation components.<br />

The SIMATIC Panel <strong>PC</strong>s can be ordered together with<br />

WinCC flexible or WinCC as SIMATIC HMI Packages with a price<br />

advantage (see SIMATIC HMI all-in-one systems).<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

3/45<br />

3


3<br />

HMI devices for special requirements<br />

Devices with stainless steel front<br />

SIMATIC HMI I<strong>PC</strong>677C INOX<br />

■ Design<br />

The HMI I<strong>PC</strong>677C INOX comprises a computer unit and an<br />

operator control unit.<br />

Components of the computer unit:<br />

Rugged metal enclosure, resistant to vibrations and shocks,<br />

with high electromagnetic compatibility<br />

Processor:<br />

- Intel Celeron 1.86 GHz, 2 cores<br />

- Intel Core i3 2.13 GHz, 2 cores, hyper-threading or<br />

- Intel Core i7 2.53 GHz, 2 cores, hyper-threading, turbo boost<br />

Main memory basic configuration: 1 GB<br />

3.5" SATA hard disk: ≥ 250 GB; the special vibration-absorbing<br />

hard disk support ensures reliable operation even under<br />

extreme mechanical stress<br />

Graphics integrated on CPU (Intel Graphics Media<br />

Accelerator)<br />

Interfaces:<br />

- 2 x 10/100/1000 Ethernet<br />

- PROFIBUS DP/MPI on board, floating<br />

- PROFINET (IRT-capable), 3-port, switching-enabled,<br />

CP 1616-compatible<br />

- 4 x USB 2.0 connection<br />

- 1 x serial V.24 (9-pin)<br />

Retentive memory:<br />

- 2 MB NVRAM, can be used with WinAC RTX 128 KB<br />

(AC and DC versions)<br />

Free slots for expansions:<br />

- 2 x <strong>PC</strong>I (slots with card retainer)<br />

- 1 x slot for CompactFlash card<br />

Power supply: 110/230 V AC (autorange), 50/60 Hz or 24 V DC<br />

DVI-I interface for connecting a further monitor (DVI or VGA)<br />

or Flat Panel<br />

Optional additional components:<br />

Main memory expansion to 2, 3, or 4 GB, or 2 or 4 GB with<br />

ECC<br />

SATA hard disk ≥ 500 GB<br />

Dual hard disk module 2 x ≥ 250 GB SATA as single disk<br />

configuration or RAID1 preconfigured<br />

Internal CF card slot (empty, instead of hard disk and optical<br />

drive; only with Windows XP embedded operating system)<br />

DVD±RW±R combo drive<br />

1 x <strong>PC</strong>Ie x 16 / 1 x <strong>PC</strong>I instead of 2 x <strong>PC</strong>I slots (with card<br />

retainers)<br />

3/46<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Components of the operator control unit:<br />

The operator control unit is available in the following version:<br />

15" Touch, stainless steel/INOX<br />

15.1" TFT color display, 1024 x 768 (XGA)<br />

Resistive analog touch screen<br />

Stainless steel front, designed for use in the food, beverage<br />

and tobacco industries<br />

Developed based on EN 1672-2<br />

Polished surface (stainless steel 1.4301, brushed metal finish,<br />

grain 240)<br />

IP66k on the front<br />

Without USB front interface<br />

Shatter protection for the display<br />

Optimized frame surface to allow liquids to run off<br />

Minimized grooves and gaps<br />

Decorative foil tested against chemicals in accordance with<br />

DIN 42115, Part 2<br />

Mounting with clamping frame only. Sealing material food-safe<br />

(EDPM, in accordance with FDA 21 CFR 177.2006)<br />

Prepared for EHEDG certification of complete machine<br />

The operator control unit complies with the requirements of<br />

degrees of protection IP66K and NEMA 4.<br />

The computer unit is connected to the rear of the operator<br />

control unit using cables.<br />

Expansion components<br />

SIMATIC I<strong>PC</strong> DiagMonitor<br />

<strong>PC</strong> diagnostics/alarm software for the early detection and<br />

diagnosis of <strong>PC</strong> problems<br />

Comprehensive monitoring of temperature, fans, hard disks<br />

(SMART), watchdog<br />

Operating hours counter for preventive maintenance<br />

Integrated log functions, comprehensive text messages,<br />

online help (English/German)<br />

Network-wide monitoring via SNMP and O<strong>PC</strong> interface<br />

possible<br />

Integrated Web server for monitoring over the network using a<br />

Web browser<br />

SIMATIC I<strong>PC</strong> Image & Partition Creator<br />

Software tool for simple and fast saving and restoring of hard<br />

disk contents (images of individual partitions or complete hard<br />

disks) and for simple subsequent modification of the hard disk<br />

partitioning without data loss.


© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI devices for special requirements<br />

Devices with stainless steel front<br />

SIMATIC HMI I<strong>PC</strong>677C INOX<br />

■ Design (continued)<br />

■ Integration<br />

SIMATIC I<strong>PC</strong> USB FlashDrive<br />

Integrated interfaces<br />

Mobile memory medium for SIMATIC <strong>PC</strong>/PG<br />

Ethernet<br />

Fast data transfer (USB 2.0) and high memory capacity<br />

The integrated Ethernet interfaces (10/100/1000 Mbit/s) can<br />

Ultra-compact and rugged<br />

be used for IT communication and for data exchange with<br />

programmable controllers such as SIMATIC S7<br />

Industrial USB Hub 4<br />

(with software package "SOFTNET S7").<br />

USB I/O can be connected and operated without opening the<br />

control cabinet door using the Industrial Hub 4.<br />

Industry-standard USB 2.0 hub, front IP65<br />

Installation in control cabinet door or on DIN rail<br />

PROFIBUS<br />

The floating PROFIBUS interface (12 Mbit/s) can be used for<br />

connecting distributed field devices or for coupling to<br />

SIMATIC S7 (with software package "SOFTNET for<br />

PROFIBUS").<br />

Inspection window and LEDs for each of the four interfaces PROFINET<br />

The three PROFINET ports (with IRT capability) can be used<br />

Note:<br />

to connect distributed I/O, SIMATIC S7, and drives. The ports<br />

with switching capability of the CP1616-compatible<br />

For further information, see "Expansion components".<br />

PROFINET option support line and tree topologies<br />

■ Function<br />

(WinAC RTX from version 2008). The interface can be<br />

alternatively used as a standard Windows interface.<br />

Integrated, parameterizable monitoring functions (program<br />

execution (watchdog), internal temperature of enclosure,<br />

fan speed)<br />

Expanded diagnostics/alarms over Ethernet, by e-mail, as text<br />

message, and for direct infeed in SIMATIC software over O<strong>PC</strong><br />

(optionally through SIMATIC I<strong>PC</strong> DiagMonitor)<br />

Further interfaces<br />

For connecting additional I/O devices, 2 free slots are<br />

available for <strong>PC</strong>I modules or alternatively 1 x <strong>PC</strong>I and 1 x <strong>PC</strong>Ie<br />

x16 modules, as well as a CompactFlash Card interface,<br />

4 USB 2.0 interfaces (Universal Serial Bus), and one serial<br />

interface.<br />

RAID1 for automatic data mirroring on two SATA hard disks ■ Technical specifications<br />

SIMATIC HMI I<strong>PC</strong>677C INOX<br />

15" Touch<br />

General features<br />

Front panel<br />

Display<br />

15" TFT Touch<br />

Screen diagonal 15"<br />

Resolution (W x H in pixels) 1024 x 768<br />

MTBF of backlighting (at 25 °C)<br />

Type of operation<br />

50 000 h at 24 h continuous<br />

operation, temperaturedependent<br />

Touch screen<br />

Design<br />

Yes<br />

Central design<br />

Dimensions<br />

Yes<br />

Installation cutout/device depth 450 x 290 x 142<br />

(W x H x D) in mm<br />

(incl. optical drive)<br />

Mounting dimensions in centralized<br />

configuration (W x H x D, without<br />

optical drive) in mm<br />

450 x 290 x 121<br />

Additional mounting depth<br />

(optical drive) in mm<br />

Weight<br />

21<br />

HMI I<strong>PC</strong> in a centralized configuration<br />

approx.<br />

14 kg<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

3/47<br />

3


3<br />

HMI devices for special requirements<br />

Devices with stainless steel front<br />

SIMATIC HMI I<strong>PC</strong>677C INOX<br />

■ Ordering data Order No. Order No.<br />

Panel <strong>PC</strong> configurator<br />

(job-oriented production<br />

and delivery)<br />

SIMATIC HMI I<strong>PC</strong>677C INOX<br />

Front panels<br />

Front options<br />

D 6AV7 89 7 - 777 7 7 - 7 7 7 7<br />

15" Touch INOX front, without<br />

front USB<br />

Power supply<br />

2 2<br />

24 V DC A<br />

110/230 V AC, power cable for<br />

Europe<br />

B<br />

110/230 V AC (without power<br />

cable)<br />

C<br />

110/230 V AC, power cable for<br />

UK<br />

D<br />

110/230 V AC, power cable for<br />

CH<br />

E<br />

110/230 V AC, power cable for<br />

the USA<br />

F<br />

110/230 V AC, power cable for<br />

Italy<br />

G<br />

110/230 V AC, power cable for<br />

China<br />

Processor<br />

H<br />

Intel Celeron P4505, 1.86 GHz<br />

(2 Mbyte shared cache), 2 cores<br />

A<br />

Intel Celeron P4505, 1.86 GHz<br />

(2 MB shared cache), 2 cores,<br />

PROFIBUS MPI, 2 MB buffered<br />

SRAM<br />

B<br />

Intel Celeron P4505, 1.86 GHz<br />

(2 MB shared cache), 2 cores,<br />

PROFINET (3 x RJ45,<br />

CP 1616-compatible),<br />

2 MB buffered SRAM<br />

C<br />

Intel Core i3-330E, 2.16 GHz<br />

(3 MB shared cache), 2 cores,<br />

hyper-threading<br />

D<br />

Intel Core i3-330E, 2.16 GHz<br />

(3 MB shared cache), 2 cores,<br />

hyper-threading, PROFIBUS<br />

MPI, 2 MB buffered SRAM<br />

E<br />

Intel Core i3-330E, 2.16 GHz<br />

(3 MB shared cache), 2 cores,<br />

hyper-threading, PROFINET<br />

(3 x RJ45, CP 1616-compatible),<br />

2 MB buffered SRAM<br />

F<br />

Intel Core i7-610E, 2.53 GHz<br />

(4 MB shared cache), 2 cores,<br />

hyper-threading, turbo boost<br />

G<br />

Intel Core i7-610E, 2.53 GHz<br />

(4 MB shared cache), 2 cores,<br />

hyper-threading, turbo boost,<br />

PROFIBUS MPI, 2 MB buffered<br />

SRAM<br />

H<br />

Intel Core i7-610E, 2.53 GHz<br />

(4 MB shared cache), 2 cores,<br />

hyper-threading, turbo boost,<br />

PROFINET (3 x RJ45,<br />

CP 1616-compatible),<br />

2 MB buffered SRAM<br />

J<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

1) Multi-language means: Ger/En/Fr/It/Sp/CHIN traditional/<br />

CHIN simplified/KOR/JAP<br />

2) Not with internal second CF card slot<br />

3) Only without RAID 1 option<br />

3/48<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC HMI I<strong>PC</strong>677C INOX D 6AV7 89 7 - 7 7 777 - 7 777<br />

Main memory<br />

1 GB DDR3 0<br />

2 GB DDR3 1<br />

3 GB DDR3 2<br />

4 GB DDR3 3<br />

2 GB DDR3 with ECC 5<br />

4 GB DDR3 with ECC 6<br />

Mass storage<br />

250 GB SATA hard disk 0<br />

500 GB SATA hard disk 1<br />

RAID1 dual hard disk module<br />

2<br />

2 x 250 GB SATA, preconfigured<br />

Dual hard disk module<br />

3<br />

2 x 250 GB SATA<br />

32 GB SSD (SLC)<br />

4<br />

Second CF card slot (only in<br />

5<br />

combination with Windows XP<br />

embedded), internal, not fitted,<br />

only with version without opt.<br />

drive and without HDD<br />

Optical drives<br />

Without 0<br />

DVD±RW±R combo drive 1<br />

Slots<br />

2 x <strong>PC</strong>I free A<br />

1 x <strong>PC</strong>I, 1 x <strong>PC</strong>Ie (x16) free B<br />

Operating system<br />

Without operating system A<br />

Windows XP Professional<br />

B<br />

Multi-Language 1) 2)<br />

Windows Windows 7 Ultimate<br />

Multi-Language 2)<br />

C<br />

Windows Embedded Standard<br />

on 8 GB CF card 3)<br />

Panel <strong>PC</strong> configurator<br />

(job-oriented production<br />

and delivery)<br />

D<br />

Software supplied with the<br />

product<br />

Without 0<br />

SIMATIC I<strong>PC</strong> DiagMonitor 1<br />

SIMATIC I<strong>PC</strong> Image & Partition<br />

2<br />

Creator<br />

SIMATIC I<strong>PC</strong> DiagMonitor and<br />

3<br />

I<strong>PC</strong> Image & Partition Creator


HMI devices for special requirements<br />

Devices with stainless steel front<br />

■ Ordering data Order No. Order No.<br />

Accessories<br />

Memory expansion<br />

1 GB DDR3 DIMM A 6ES7 648-2AJ40-0KA0<br />

2 GB DDR3 DIMM A 6ES7 648-2AJ50-0KA0<br />

1 GB DDR3 DIMM with ECC A 6ES7 648-2AJ40-1KA0<br />

2 GB DDR3 DIMM with ECC<br />

Non-heating apparatus cable<br />

for SIMATIC Box and Panel <strong>PC</strong><br />

SIMATIC <strong>PC</strong> power cable,<br />

230 V AC, angled, 3 m,<br />

for:<br />

A 6ES7 648-2AJ50-1KA0<br />

Germany 6ES7 900-1AA00-0XA0<br />

United Kingdom 6ES7 900-1BA00-0XA0<br />

Switzerland 6ES7 900-1CA00-0XA0<br />

USA 6ES7 900-1DA00-0XA0<br />

Italy 6ES7 900-1EA00-0XA0<br />

China 6ES7 900-1FA00-0XA0<br />

Touch pen<br />

Captive pen for operation of the<br />

touch devices, mounting of the<br />

support on the control cabinet<br />

6AV7 672-1JB00-0AA0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC HMI I<strong>PC</strong>677C INOX<br />

Expansion components<br />

SIMATIC I<strong>PC</strong> DiagMonitor V4.2<br />

Software tool for monitoring<br />

SIMATIC I<strong>PC</strong>s, incl. manual, on<br />

CD-ROM (German/English)<br />

B 6ES7 648-6CA04-2YX0<br />

SIMATIC I<strong>PC</strong> Image & Partition D<br />

Creator V3.1<br />

Software tool for preventive data<br />

backup and hard disk partitioning<br />

for SIMATIC <strong>PC</strong>s, incl. manual on<br />

CD-ROM (German, English)<br />

6ES7 648-6AA03-1YA0<br />

SIMATIC I<strong>PC</strong> USB FlashDrive<br />

8 GB, USB 2.0; metal enclosure,<br />

bootable<br />

A 6ES7 648-0DC50-0AA0<br />

SIMATIC I<strong>PC</strong> Service<br />

USB FlashDrive<br />

8 GB, USB 2.0, metal enclosure,<br />

bootable, Image & Partition<br />

Creator pre-installed, incl. CD<br />

6AV7 672-8JD01-0AA0<br />

Industrial USB Hub 4<br />

4 x USB 2.0 interfaces, IP65 for<br />

mounting on control cabinet door<br />

or DIN rail<br />

Uninterruptible power supplies<br />

A 6AV6 671-3AH00-0AX0<br />

SITOP power, battery module<br />

24 V/3.2 Ah<br />

for DC UPS module 15 A<br />

Communication components<br />

<strong>PC</strong>I interface card<br />

6EP1 935-6MD11<br />

With COM1, COM2 and LPT<br />

interfaces<br />

A 6ES7 648-2CA01-0AA0<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

3/49<br />

3


3<br />

HMI devices for special requirements<br />

Devices with stainless steel front<br />

SIMATIC HMI I<strong>PC</strong>677C INOX<br />

■ Dimensional drawings<br />

All specifications in mm.<br />

Panel cutout see technical specifications.<br />

G<br />

Panel <strong>PC</strong> 677C INOX 15" Touch<br />

Control units<br />

<strong>PC</strong> 677 INOX<br />

Touch devices<br />

G H J K L M N<br />

15" 289 271 138 11 24 367 42<br />

3/50<br />

H<br />

J<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

K<br />

K<br />

L<br />

N<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

M<br />

G_<strong>ST</strong><strong>80</strong>_XX_00288<br />

■ More information<br />

Additional information is available in the Internet under:<br />

www.siemens.com/inox-hmi-devices<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? Under "Customized products", you<br />

can find information about additional and generally available<br />

products for the sector, and about the possibilities for<br />

customized modification and adaptation.


■ Overview<br />

The SIMATIC HMI Ex devices are intrinsically-safe Panel <strong>PC</strong>s<br />

and Thin Clients which have been specially developed for<br />

hazardous areas.<br />

Available as HMI devices for hazardous areas "Zone 1" and<br />

"Zone 2" are:<br />

SIMATIC HMI Panel <strong>PC</strong> Ex<br />

SIMATIC HMI Thin Client Ex<br />

Further SIMATIC HMI devices are also available for the<br />

hazardous area "Zone 2" and can be found in the chapter<br />

"Operator panels":<br />

SIMATIC Comfort Panels<br />

SIMATIC TP 177B / TP 177B INOX<br />

SIMATIC TP 277<br />

SIMATIC MP 277 / MP 277 INOX<br />

SIMATIC MP 377 / MP 377 INOX<br />

■ Benefits<br />

Intrinsically-safe design for direct use in various areas with<br />

potentially explosive atmospheres<br />

Various certificates such as ATEX 1/21/2/22, GO<strong>ST</strong>-R,<br />

UL Class 1, Division 2, marine approval, etc.<br />

Extended temperature range from -20 °C to +50 °C (in<br />

operation) – with supplementary heating and additional<br />

enclosure down to -30 °C<br />

Completely maintenance-free – no fan, hard disk (optional) or<br />

battery<br />

Thin Client concept also allows operation as remote monitor<br />

(with digital KVM)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI devices for special requirements<br />

HMI devices for hazardous areas<br />

■ Application<br />

HMI devices for hazardous areas<br />

The SIMATIC HMI Ex devices have been designed for installation<br />

directly in hazardous areas. The intrinsically-safe design<br />

allows simple installation on site. The variety of certification<br />

allows use in many parts of the world without further approvals.<br />

Different versions are available for use in different hazardous<br />

zones:<br />

"Zone 1" with ATEX 1 / 21, UL-Inmetro and GO<strong>ST</strong>-R certification<br />

"Zone 2" with ATEX 2 / 22 and GO<strong>ST</strong>-R certification<br />

"UL Class 1, Division 2"<br />

The devices can be used directly in ambient temperatures from<br />

-20 °C to +50 °C (cold start down to -10 °C). In combination with<br />

a stainless steel enclosure and the integrated heater even down<br />

to -30 °C! This special enclosure is available in various designs<br />

and mounting styles, and permits fast installation without further<br />

assembly steps.<br />

With a weight of 15 to 23 kg, the devices are very light for this<br />

class.<br />

The devices are fanless and permit completely maintenancefree<br />

installation without batteries or rotating parts.<br />

■ Design<br />

General<br />

IP66 protection at front, IP65 at rear<br />

Energy-saving design<br />

15" TFT color display, 1024 x 768 pixels (XGA)<br />

15" TFT color display, 1024 x 768 pixels (XGA),<br />

high-brightness display<br />

19" TFT color display, 12<strong>80</strong> x 1024 pixels (SXGA)<br />

Analog touch screen, resistive<br />

Function keys, tactile, F1-F8<br />

Terminals for 24 V DC power supply<br />

Accessories<br />

Additional enclosure with various mounting styles<br />

Handles for enclosure<br />

Heaters for extension of temperature range<br />

Keyboards in various languages – also with trackball<br />

USB sticks (some of which intrinsically-safe)<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

3/51<br />

3


3<br />

HMI devices for special requirements<br />

HMI devices for hazardous areas<br />

HMI devices for hazardous areas<br />

■ Technical specifications<br />

SIMATIC HMI Panel <strong>PC</strong> Ex SIMATIC HMI Thin Client Ex<br />

Design Panel <strong>PC</strong> with Intel Atom CPU Thin Client<br />

Operating system Windows XP Embedded or XP Professional closed system, based on XP Embedded<br />

Temperature -20 °C to +50 °C (cold start down to -10 °C)<br />

-20 °C to +50 °C (cold start down to -10 °C)<br />

with additional heating down to -30 °C<br />

with additional heating down to -30 °C<br />

Degree of protection<br />

Approvals<br />

IP66 at front, IP65 at rear IP66 at front, IP65 at rear<br />

Version "Zone 1" II 2 (2) G Ex d e mb ib [ib] [op is] IIC T4<br />

II 2 (2) G Ex d e mb ib [ib] [op is] IIC T4<br />

II 2 D Ex tD A21 IP65 T90 °C<br />

II 2 D Ex tD A21 IP65 T90 °C<br />

DNV (marine engineering)<br />

DNV (marine engineering)<br />

GO<strong>ST</strong>-R<br />

GO<strong>ST</strong>-R<br />

UL-Inmetro<br />

UL-Inmetro<br />

Version "Zone 2" II 3 (3) G Ex d e mb nA nL [nL] [op is] IIC T4 II 3 (3) G Ex d e mb nA nL [nL] [op is] IIC T4<br />

II 3 (2) G Ex d e mb nA nL [ib] [op is] IIC T4<br />

II 3 (2) G Ex d e mb nA nL [ib] [op is] IIC T4<br />

II 3 (2) D Ex tD A22 IP65 [ibD] T90 °C<br />

II 3 (2) D Ex tD A22 IP65 [ibD] T90 °C<br />

GO<strong>ST</strong>-R<br />

GO<strong>ST</strong>-R<br />

Version "UL Class 1, Division 2" Class 1, Division 2, Groups A,B,C,D<br />

Class 2, Division 2, Groups F,G<br />

Class 3, Hazardous Locations<br />

-<br />

Dimensions<br />

Panel cut-out<br />

(W X H X D)<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-hmi-ex<br />

3/52<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

15": 427.5 mm x 327.5 mm x 165 mm<br />

19": 522.5 mm x 412.5 mm x 165 mm<br />

Front (W X H) 15": 440 mm x 340 mm<br />

19": 535 mm x 425 mm<br />

Weight 15": 15 kg<br />

19": 23 kg<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

15": 427.5 mm x 327.5 mm x 165 mm<br />

19": 522.5 mm x 412.5 mm x 165 mm<br />

15": 440 mm x 340 mm<br />

19": 535 mm x 425 mm<br />

15": 15 kg<br />

19": 23 kg


■ Overview<br />

SIMATIC HMI Panel <strong>PC</strong> Ex with international approvals for<br />

operation and monitoring in hazardous areas.<br />

■ Application<br />

The SIMATIC HMI Panel <strong>PC</strong> Ex is a Panel <strong>PC</strong> for use directly in<br />

hazardous areas. The device is both an ideal platform for<br />

(maintenance-free) embedded applications, as well as a flexible<br />

platform for applications under Windows XP Professional.<br />

■ Integration<br />

Configuration and integrated interfaces with SIMATIC HMI Panel<br />

<strong>PC</strong> Ex:<br />

Intel Atom N270 CPU with 1.6 GHz and 1 GB DDR2 RAM<br />

Mass memory 4 GB or 16 GB Flash with Windows XP<br />

Embedded or <strong>80</strong> GB or 120 GB hard disk with<br />

Windows XP Professional<br />

10/100 Mbit 100 base TX (Ex e) or 100 base FX (Ex op is) fiberoptic<br />

network<br />

1 x RS232 or 1 x RS422/485<br />

4 x USB 2.0 (2 x Ex I, 2 x Ex e (version Zone 1) or 2 x Ex nA<br />

(version Zone 2))<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI devices for special requirements<br />

HMI devices for hazardous areas<br />

SIMATIC HMI Panel <strong>PC</strong> Ex<br />

■ Technical specifications<br />

SIMATIC HMI Panel <strong>PC</strong> Ex<br />

General features<br />

Design Panel <strong>PC</strong> built-in unit, protective<br />

enclosure available as an option<br />

Front 15" and 19", optional 15" high-brightness<br />

display<br />

Operation Touch with 8 function keys<br />

Processor Intel Atom N270 with 1.6 GHz<br />

Main memory 1 GB DDR2 SDRAM<br />

Operating system, Windows XP Professional, Windows XP<br />

preinstalled and<br />

Embedded<br />

configured<br />

Mass storage CompactFlash 4 GB / 16 GB, hard disk<br />

<strong>80</strong> GB / 120 GB<br />

Power supply 24 V DC, max. 2.1 A (19")<br />

Interfaces<br />

Ethernet 10/100 Mbit Ex e, or fiber-optics 100 Mbit<br />

(SC) Ex op is<br />

USB 2.0 2 x Ex i, 2 x Ex e (Zone 1) or 2 x Ex nA<br />

(Zone 2)<br />

Serial 1 x RS232 or 1 x RS422/485<br />

Ambient conditions<br />

Degree of protection IP66 at front, IP65 at rear, IP66 in<br />

protective enclosure<br />

Ambient temperature during -20 °C ... +50 °C (cold start -10 °C)<br />

operation<br />

with optional additional heating down to<br />

-30 °C<br />

Relative humidity during 90 % at + 40 °C, no condensation<br />

operation<br />

Approvals/directives<br />

Devices in version "Zone 1" II 2 (2) G Ex d e mb ib [ib] [op is] IIC T4<br />

II 2 D Ex tD A21 IP65 T90 °C<br />

DNV (marine engineering), GO<strong>ST</strong>-R,<br />

UL-Inmetro<br />

Devices in version "Zone 2" II 3 (3) G Ex d e mb nA nL [nL] [op is] IIC<br />

T4<br />

II 3 (2) G Ex d e mb nA nL [ib] [op is] IIC<br />

T4<br />

II 3 (2) D Ex tD A22 IP65 [ibD] T90 °C,<br />

GO<strong>ST</strong>-R<br />

Version "UL Class 1, Class 1, Division 2, Groups A,B,C,D<br />

Division 2"<br />

Class 2, Division 2, Groups F,G<br />

Class 3, Hazardous Locations<br />

Dimensions<br />

Mounting dimensions 15": 427.5 mm x 327.5 mm x 165 mm<br />

(W x H x D)<br />

19": 522.5 mm x 412.5 mm x 165 mm<br />

Front dimensions (W x H) 15": 440 mm x 340 mm<br />

19": 535 mm x 425 mm<br />

Weight 15": 15 kg<br />

19": 23 kg<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

3/53<br />

3


3<br />

HMI devices for special requirements<br />

HMI devices for hazardous areas<br />

SIMATIC HMI Panel <strong>PC</strong> Ex<br />

■ Ordering data Order No. Order No.<br />

Configuration<br />

SIMATIC HMI Panel <strong>PC</strong> Ex<br />

Design / display size<br />

E 6AV7 20 0 - 1 7 7 7 7 - 7 7 A 0<br />

Zone 2: 15" Touch with function<br />

keys<br />

A<br />

Zone 2: 19" Touch with function<br />

keys<br />

B<br />

Zone 1: 15" Touch with function<br />

keys<br />

D<br />

Zone 1: 19" Touch with function<br />

keys<br />

E<br />

Zone 1: 15" Touch, highbrightness<br />

with function keys<br />

F<br />

UL Class 1, Division 2:<br />

15" Touch with function keys<br />

G<br />

UL Class 1, Division 2:<br />

19" Touch with function keys<br />

Communication interfaces<br />

H<br />

10/100 base Tx, Ex e A<br />

100 base Fx FOC (SC), Ex op is B<br />

Mass storage<br />

CF 4 GB 1<br />

CF 16 GB 2<br />

HDD 60 GB 3<br />

HDD 120 GB 4<br />

Operating system (preinstalled)<br />

Windows XP Embedded on CF<br />

(language package 1) 1)<br />

1<br />

Windows XP Embedded on CF<br />

(language package 2) 2)<br />

2<br />

Windows XP Professional MUI<br />

3<br />

(only on HDD)<br />

Enclosure options<br />

(device is delivered already fitted)<br />

without 0<br />

Stainless steel enclosure for:<br />

- Wall mounting 2<br />

- Stand (incl. coupling, 300°<br />

3<br />

rotation possible)<br />

- Suspension bracket<br />

4<br />

(incl. coupling, 300° rotation<br />

possible)<br />

- Support arm (incl. coupling,<br />

5<br />

300° rotation possible)<br />

External keyboard for stainless<br />

steel enclosure<br />

(incl. keyboard enclosure)<br />

without A<br />

QWERTZ keyboard B<br />

QWERTY keyboard C<br />

AZERTY keyboard D<br />

QWERTZ keyboard with<br />

E<br />

trackball<br />

QWERTY keyboard with<br />

F<br />

trackball<br />

AZERTY keyboard with trackball G<br />

Further options together with<br />

stainless steel enclosure<br />

Breather glands -z A01<br />

Heater -z B01<br />

Handles -z C01<br />

Front USB (at bottom) -z D01<br />

3/54<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Accessories<br />

Digital KVM<br />

for HMI Thin Client Ex<br />

USB drive<br />

A 6AV7 675-0EX00-0AA0<br />

Intrinsically-safe, 16 GB A 6AV7 675-0FX00-0AA0<br />

Intrinsically-safe, 16 GB with<br />

recovery function<br />

A 6AV7 675-0FX10-0AA0<br />

Not intrinsically-safe, 16 GB with A<br />

recovery function<br />

6AV7 675-0FX20-0AA0<br />

Ethernet switch<br />

with FOC 4 x 100 Base Tx,<br />

1 x 100 Base (MTRJ) Fx Ex op is<br />

6AV7 675-0PX00-0AA0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

1) Package 1:<br />

upon initial startup, select the language from: English, German,<br />

French, Italian, Spanish, Portuguese, Brazilian, Dutch, Danish,<br />

Swedish, Norwegian, Finnish, Greek, Hungarian, Czech, Polish,<br />

Turkish, Russian<br />

2) Package 2:<br />

upon initial startup, select the language from: English, German,<br />

Turkish, Hebrew, Arabic, Chinese, Japanese, Korean, Thai


■ Dimensional drawings<br />

All specifications in mm.<br />

Panel cutout see technical specifications.<br />

340<br />

SIMATIC HMI Panel <strong>PC</strong> Ex 15"<br />

425<br />

SIMATIC HMI Panel <strong>PC</strong> Ex 19"<br />

440<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-hmi-ex<br />

HMI devices for special requirements<br />

HMI devices for hazardous areas<br />

Legend:<br />

h = Mounting clamp (10 x)<br />

i = Clamping frame<br />

j = Control cabinet or enclosure<br />

326<br />

327.5+0.5<br />

SIMATIC HMI Panel <strong>PC</strong> Ex<br />

h<br />

426<br />

i<br />

427.5+0.5 G_<strong>ST</strong><strong>80</strong>_XX_00419<br />

535<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

411<br />

412.5+0.5<br />

h<br />

521<br />

i<br />

522.5+0.5 G_<strong>ST</strong><strong>80</strong>_XX_00420<br />

165<br />

j<br />

165<br />

j<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

3/55<br />

3


3<br />

HMI devices for special requirements<br />

HMI devices for hazardous areas<br />

SIMATIC HMI Thin Client Ex<br />

■ Overview<br />

SIMATIC HMI Thin Client Ex with international approvals for<br />

operation and monitoring in hazardous areas.<br />

■ Application<br />

The SIMATIC HMI Thin Client Ex is designed for use as an<br />

operator station for terminal and client applications in hazardous<br />

areas, and in particular for applications for which the performance<br />

of the SIMATIC HMI Panel <strong>PC</strong> Ex is insufficient, or when<br />

the server is located in a protected area of the plant. The widelyused<br />

RDP and Real VNC protocols are supported.<br />

Together with the digital KVM Box, the device functions as a<br />

flexible monitor with touch functionality for <strong>PC</strong>s e. g. in control<br />

rooms.<br />

■ Integration<br />

Integrated interfaces with SIMATIC HMI Thin Client Ex:<br />

10/100 Mbit 100 base TX (Ex e) or 100 base FX (Ex op is)<br />

network<br />

1 x RS232 or 1 x RS422/485<br />

4 x USB 2.0 (2 x Ex I, 2 x Ex e (version Zone 1) or 2 x Ex nA<br />

(version Zone 2))<br />

3/56<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Technical specifications<br />

SIMATIC HMI Thin Client Ex<br />

General features<br />

Design Thin Client built-in unit, available in<br />

protective enclosure as an option<br />

Front 15", 19" and 15" high-brightness<br />

displays<br />

Operation Touch with 8 function keys<br />

MTBF backlight 50 000 h<br />

Operating system Closed system on Windows XP<br />

Embedded basis<br />

Mass storage Integrated<br />

Power supply 24 V DC, max. 2.1 A (19")<br />

Interfaces<br />

Ethernet 100 Mbit Ex e, or alternatively<br />

fiber-optics 100 Mbit (SC) Ex op is<br />

USB 2.0 2 x Ex i, 2 x Ex e (Zone 1) or 2 x Ex nA<br />

(Zone 2)<br />

Serial 1 x RS232 or 1 x RS422/485<br />

Ambient conditions<br />

Degree of protection IP66 at front, IP65 at rear, IP66 in<br />

protective enclosure<br />

Ambient temperature during -20 °C ... +50 °C, cold start -10 °C,<br />

operation<br />

with optional additional heating down<br />

to -30 °C<br />

Relative humidity during 90 % at 40 °C, no condensation<br />

operation<br />

Approvals/directives<br />

Devices in version "Zone 1" II 2 (2) G Ex d e mb ib [ib] [op is]<br />

IIC T4<br />

II 2 D Ex tD A21 IP65 T90 °C<br />

DNV (marine engineering), GO<strong>ST</strong>-R<br />

Devices in version "Zone 2" II 3 (3) G Ex d e mb nA nL [nL] [op is]<br />

IIC T4<br />

II 3 (2) G Ex d e mb nA nL [ib] [op is]<br />

IIC T4<br />

II 3 (2) D Ex tD A22 IP65 [ibD] T90 °C,<br />

GO<strong>ST</strong>-R<br />

Protocols RDP, RealVNC<br />

Digital KVM switch Input: DVI / VGA, PS2 / USB, output:<br />

RJ45 (IP network)<br />

Dimensions<br />

Mounting dimensions<br />

15": 427.5 x 327.5 x 165<br />

(W x H x D) in mm<br />

19": 522.5 x 412.5 x 165<br />

Front dimensions in mm 15": 440 x 340<br />

19": 535 x 425<br />

Weight 15": 15 kg, 19": 23 kg


A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI devices for special requirements<br />

HMI devices for hazardous areas<br />

SIMATIC HMI Thin Client Ex<br />

■ Ordering data Order No. Order No.<br />

Configuration<br />

Accessories<br />

SIMATIC HMI Thin Client Ex E 6AV7 20 0 - 0 7 7 0 0 - 7 7 A 0 Digital KVM<br />

A 6AV7 675-0EX00-0AA0<br />

Design / display size<br />

for HMI Thin Client Ex<br />

Zone 2: 15" Touch with function<br />

keys<br />

A<br />

USB drive<br />

Intrinsically-safe, 16 GB A 6AV7 675-0FX00-0AA0<br />

Zone 2: 19" Touch with function<br />

keys<br />

B<br />

Intrinsically-safe, 16 GB with<br />

recovery function<br />

A 6AV7 675-0FX10-0AA0<br />

Zone 1: 15" Touch with function<br />

keys<br />

D<br />

Not intrinsically-safe, 16 GB with A<br />

recovery function<br />

6AV7 675-0FX20-0AA0<br />

Zone 1: 19" Touch with function<br />

keys<br />

E<br />

Ethernet switch A 6AV7 675-0PX00-0AA0<br />

Zone 1: 15" Touch,<br />

high-brightness with function<br />

keys<br />

Communication interfaces<br />

F<br />

With FOC 4 x 100 Base Tx,<br />

1 x 100 Base (MTRJ) Fx Ex op is<br />

10/100 base Tx, Ex e A<br />

100 base Fx FOC (SC), Ex op is<br />

Enclosure options<br />

(device is delivered already fitted)<br />

B<br />

without<br />

Stainless steel enclosure for:<br />

0<br />

- Wall mounting 2<br />

- Stand (incl. coupling,<br />

300° rotation possible)<br />

3<br />

- Suspension bracket<br />

(incl. coupling, 300° rotation<br />

possible)<br />

4<br />

- Support arm (incl. coupling,<br />

300° rotation possible)<br />

External keyboard for enclosure<br />

(incl. keyboard enclosure)<br />

5<br />

without A<br />

QWERTZ keyboard B<br />

QWERTY keyboard C<br />

AZERTY keyboard D<br />

QWERTZ keyboard with<br />

trackball<br />

E<br />

QWERTY keyboard with<br />

trackball<br />

F<br />

AZERTY keyboard with trackball<br />

Further options together with<br />

stainless steel enclosure<br />

G<br />

Breather glands -z A01<br />

Heater -z B01<br />

Handles -z C01<br />

Front USB (at bottom) -z D01<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

3/57<br />

3


3<br />

HMI devices for special requirements<br />

HMI devices for hazardous areas<br />

SIMATIC HMI Thin Client Ex<br />

■ Dimensional drawings<br />

All specifications in mm.<br />

Panel cutout see technical specifications.<br />

SIMATIC HMI Thin Client Ex 15"<br />

SIMATIC HMI Thin Client Ex 19"<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-hmi-ex<br />

3/58<br />

340<br />

425<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

440<br />

Legend:<br />

h = Mounting clamp (10 x)<br />

i = Clamping frame<br />

j = Control cabinet or enclosure<br />

326<br />

327.5+0.5<br />

h<br />

426<br />

i<br />

427.5+0.5 G_<strong>ST</strong><strong>80</strong>_XX_00419<br />

535<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

411<br />

412.5+0.5<br />

h<br />

521<br />

i<br />

522.5+0.5 G_<strong>ST</strong><strong>80</strong>_XX_00420<br />

165<br />

j<br />

165<br />

j


HMI Software<br />

4/2 HMI Software<br />

4/2 Introduction<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

4/4 HMI software in the TIA Portal<br />

4/5 SIMATIC WinCC (TIA Portal)<br />

Engineering<br />

4/9 SIMATIC WinCC (TIA Portal) Runtime<br />

4/10 WinCC Runtime Advanced<br />

4/14 WinCC Runtime Professional<br />

4/19 WinCC Runtime Communication<br />

4/25 SIMATIC WinCC (TIA Portal) options<br />

4/26 WinCC Recipes<br />

4/28 WinCC Logging<br />

4/30 WinCC Audit<br />

4/31 SIMATIC Logon<br />

4/32 WinCC Sm@rtServer<br />

4/36 WinCC Server / WinCC Client<br />

4/38 WinCC WebNavigator<br />

4/41 SIMATIC WinCC flexible HMI system<br />

4/41 SIMATIC WinCC flexible ES<br />

4/46 SIMATIC WinCC flexible RT<br />

4/53 SIMATIC WinCC flexible options<br />

4/54 WinCC flexible /ChangeControl<br />

4/55 WinCC flexible /Archives<br />

4/56 WinCC flexible /Recipes<br />

4/57 WinCC flexible /Audit<br />

4/58 SIMATIC Logon for WinCC flexible<br />

4/60 WinCC flexible /Sm@rtAccess<br />

4/64 WinCC flexible /Sm@rtService<br />

4/67 WinCC flexible /O<strong>PC</strong> server<br />

4/69 WinCC flexible /ProAgent<br />

4/70 SCADA system SIMATIC WinCC<br />

4/70 SIMATIC WinCC<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4<br />

4/88 SIMATIC WinCC options<br />

4/89 WinCC/Server<br />

4/91 WinCC/Web Navigator<br />

4/96 WinCC/TeleControl<br />

4/100 WinCC/Central Archive Server (CAS)<br />

4/101 WinCC/Redundancy<br />

4/102 SIMATIC Maintenance Station<br />

4/105 WinCC/ProAgent<br />

4/106 SIMATIC powerrate<br />

4/109 WinCC/B.Data<br />

4/113 WinCC/DataMonitor<br />

4/115 WinCC/DowntimeMonitor<br />

4/117 WinCC/Connectivity Pack &<br />

WinCC Connectivity Station<br />

4/120 WinCC/IndustrialDataBridge<br />

4/123 WinCC/User Archives<br />

4/124 WinCC/Calendar Scheduler<br />

4/125 WinCC/Event Notifier<br />

4/126 SIMATIC BATCH for WinCC<br />

4/128 WinCC/ChangeControl & WinCC/Audit<br />

4/130 SIMATIC Logon<br />

4/131 WinCC/IndustrialX<br />

4/132 WinCC/Open Development Kit (ODK)<br />

4/133 WinCC add-ons<br />

and partner management<br />

4/135 SCADA System<br />

WinCC Open Architecture<br />

4/150 SIMATIC ProAgent<br />

process diagnosis software<br />

4/150 SIMATIC ProAgent


4<br />

HMI Software<br />

Introduction<br />

HMI Software<br />

■ Overview<br />

With the product families SIMATIC WinCC (TIA Portal), SIMATIC<br />

WinCC flexible and SIMATIC WinCC, SIMATIC HMI offers<br />

visualization and configuration software for the entire HMI<br />

spectrum:<br />

SIMATIC WinCC (TIA Portal)<br />

Creation of applications in the machine-level area and of<br />

process visualization or SCADA systems<br />

SIMATIC WinCC flexible<br />

Creation of applications in the machine-level area:<br />

SIMATIC WinCC<br />

Creation of process visualization or SCADA systems<br />

SIMATIC WinCC Open Architecture<br />

Creation of applications with a high demand for customerspecific<br />

adaptations, large and/or complex applications, as<br />

well as projects that demand special system requirements<br />

and functions<br />

4/2<br />

Engineering<br />

Software<br />

Runtime Software<br />

and target systems<br />

WinCC Professional<br />

WinCC Advanced<br />

WinCC Comfort<br />

WinCC Basic<br />

Basic Panels<br />

Integrated runtime<br />

module<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Comfort Panels<br />

Mobile Panels<br />

x77 Panels and<br />

Multi Panels<br />

Integrated runtime<br />

module<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based<br />

single-user system,<br />

e.g. SIMATIC I<strong>PC</strong><br />

WinCC Runtime<br />

Advanced<br />

<strong>PC</strong>-based multi-user system<br />

SCADA functionality<br />

WinCC Runtime Professional<br />

SIMATIC WinCC (TIA Portal)<br />

WinCC (TIA Portal) is based on the new central engineering<br />

framework Totally Integrated Automation Portal (TIA Portal),<br />

which provides users with an integrated, efficient and intuitive<br />

solution to all automation tasks.<br />

SIMATIC WinCC (TIA Portal) covers applications in the machinelevel<br />

area and applications in the process visualization or<br />

SCADA environment. WinCC (TIA Portal) offers the uniform and<br />

scalable configuration tools WinCC Basic, Comfort, Advanced<br />

and Professional for configuring the current SIMATIC HMI<br />

operator panels:<br />

SIMATIC Basic Panels<br />

SIMATIC Comfort Panels<br />

SIMATIC Mobile Panels<br />

SIMATIC Panels 77/177/277 series<br />

SIMATIC Multi Panels of the 177/277/377 series<br />

<strong>PC</strong>-based systems<br />

- SIMATIC WinCC Runtime Advanced<br />

- SIMATIC WinCC Runtime Professional<br />

In addition, WinCC (TIA Portal) offers:<br />

Intuitive user interface with maximum degree of operator<br />

friendliness<br />

Clear configuration of devices and network topologies<br />

Shared data management and uniform symbols via controller<br />

and HMI<br />

Optimum interaction with the controller and HMI in a working<br />

environment<br />

Powerful editors for efficient engineering<br />

Integrated mass data operations for efficient configuration<br />

System diagnostics as an integral component<br />

Comprehensive library concept<br />

G_<strong>ST</strong><strong>80</strong>_XX_00461


■ Overview (continued)<br />

SIMATIC WinCC flexible<br />

Covers applications in the machine-level area. WinCC flexible<br />

offers the integrated and scalable configuration tools WinCC<br />

flexible Micro, Compact, Standard and Advanced for configuring<br />

SIMATIC HMI operator panels:<br />

SIMATIC Basic Panels<br />

SIMATIC Mobile Panels<br />

SIMATIC Micro Panels<br />

SIMATIC Panels of the 70/170/270 series as well as C7-635<br />

and C7-636<br />

SIMATIC Multi Panels of the 170/270/370 series<br />

<strong>PC</strong>-based systems<br />

- SIMATIC WinCC flexible Runtime<br />

Runs under Windows XP Professional / Windows 7<br />

Professional, Ultimate, Enterprise<br />

Expanded integration into <strong>ST</strong>EP 7 and SIMOTION<br />

Optionally expandable with functions for version<br />

administration and logging changes<br />

(WinCC flexible /ChangeControl)<br />

Modular <strong>PC</strong>-based HMI solution for single-user systems<br />

directly at the machine level<br />

Basic package for visualization, reporting and logging; can be<br />

expanded by implementing option packages<br />

Flexible expansion possible with VB scripts and customized<br />

ActiveX controls created with OPP (Open Platform Program)<br />

SIMATIC WinCC<br />

The process visualization or SCADA system for visualizing and<br />

operating processes, production flows, machines and plants in<br />

all sectors – from the simple single-user station through to<br />

distributed multi-user systems with redundant servers and<br />

cross-location solutions with web clients. WinCC is the information<br />

hub for company-wide, vertical integration (process<br />

visualization and platform for IT & business integration).<br />

For universal use thanks to solutions for all sectors, e.g.<br />

conforming to FDA 21 CFR Part 11, and multiple languages for<br />

worldwide use<br />

All HMI functions on-board with industry-standard functions<br />

for signaling and acknowledging events, archiving of<br />

messages and measured values, logging of all process and<br />

configuration data, user administration and visualization<br />

(WinCC basic software)<br />

Company-wide, flexible client/server structures with operator<br />

stations on the Web, distributed servers and data integrity<br />

thanks to redundancy<br />

Easy to integrate over standard interfaces such as O<strong>PC</strong> (OLE<br />

for Process Control), WinCC OLE-DB, VBA (Visual Basic for<br />

Applications), VB script, C-API (ODK)<br />

Integration platform in the company thanks to the Historian<br />

functionality integrated into WinCC based on the Microsoft<br />

SQL Server, standard and programming interfaces and tools<br />

and clients for evaluation<br />

Modular expansion with options and add-ons as well as<br />

individual function expansions with VB Script, Visual Basic for<br />

Applications, C-API (ODK) and integration of ActiveX<br />

elements<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

Introduction<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

HMI Software<br />

SIMATIC WinCC Open Architecture<br />

The process visualization and control system SIMATIC WinCC<br />

Open Architecture addresses applications with high demand for<br />

customer-specific adaptations, large and/or complex applications,<br />

as well as projects that demand special system requirements<br />

and functions.<br />

SIMATIC WinCC Open Architecture demonstrates its high<br />

performance in networked and redundant high-end control<br />

systems in particular. From the field level to the control station,<br />

from the machine to the company headquarters – integrated,<br />

high-performance communication is guaranteed. In every<br />

situation, a high level of availability, reliable information, fast<br />

interaction and user friendliness are guaranteed. Applications<br />

can also be changed without interrupting the process. Profitability,<br />

efficiency and safety are therefore always in equilibrium.<br />

With its disaster recovery system and SIL3 certification, SIMATIC<br />

WinCC Open Architecture demonstrates its reliability in a wide<br />

range of critical applications. SIMATIC WinCC Open Architecture<br />

can be used on any platform and is available for<br />

Windows, Linux and Solaris.<br />

SIMATIC WinCC Open Architecture is open for independent inhouse<br />

developments, which means that ideas can be turned into<br />

new applications quickly and easily.<br />

Object-orientation supports efficient engineering and flexible<br />

plant expansion<br />

For large, distributed systems with up to 2048 servers<br />

Scalable – from a small single-user system up to a networked,<br />

redundant high-end system<br />

WinCC OA can be used on any platform and is available for<br />

Windows, Linux and Solaris<br />

Hot-standby redundancy and disaster recovery system<br />

assure maximum fail-safety and availability<br />

WinCC OA offers a platform for customer-specific solutions<br />

Extensive driver and interfacing options: S7, SINAUT, O<strong>PC</strong>,<br />

O<strong>PC</strong> UA, Modbus, IEC 60870-5-101/104, DNP3, BACnet, and<br />

many others.<br />

Flexible logging of data either in file-based value archive or in<br />

a relational database (ORACLE)<br />

Modular expansion using options and add-ons as well as<br />

individual function expansions by means of own script<br />

language CONTROL, API(C++) and integration of ActiveX<br />

elements.<br />

4/3<br />

4


4<br />

HMI Software<br />

HMI software in the TIA Portal<br />

HMI software in the TIA portal<br />

■ Overview<br />

SIMATIC WinCC (TIA Portal) engineering software<br />

Family of configuration systems with WinCC Basic, Comfort,<br />

Advanced and Professional for SIMATIC operator panels, as<br />

well as for the <strong>PC</strong>-based visualization systems WinCC<br />

Runtime Advanced and WinCC Runtime Professional<br />

SIMATIC WinCC Runtime Advanced visualization software<br />

<strong>PC</strong>-based HMI solution for single-user systems directly at the<br />

machine<br />

Basic package for visualization, reporting and logging, user<br />

administration, can be expanded flexibly with VB scripts<br />

Basic package expandable by means of option packages<br />

Integration of customer-specific ActiveX Controls created with<br />

WinCC ControlDevelopment<br />

Can be integrated into automation solutions based on TCP/IP<br />

networks<br />

Expanded service concepts with remote operation,<br />

diagnostics and administration over the Intranet and Internet<br />

in combination with e-mail communication<br />

4/4<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC WinCC Runtime Professional visualization<br />

software<br />

<strong>PC</strong>-based operator control and monitoring system for<br />

visualization and operator control of processes, production<br />

flows, machines and plants in all sectors – from the simple<br />

single-user station through to distributed multi-user systems<br />

and cross-location solutions with web clients. WinCC Runtime<br />

Professional is the information hub for corporation-wide<br />

vertical integration.<br />

Industry-standard functions for signaling and acknowledging<br />

events, archiving of messages and measured values, logging<br />

of all process and configuration data, user administration, can<br />

be expanded flexibly with VB and C scripts<br />

Basic package expandable by means of option packages<br />

Also included are APIs for the Runtime to utilize the open<br />

programming interfaces<br />

Integration of customer-specific ActiveX Controls created with<br />

WinCC ControlDevelopment


■ Overview<br />

Integrated family of engineering tools for configuring<br />

SIMATIC HMI operator panels, as well as for the <strong>PC</strong>-based<br />

visualization systems WinCC Runtime Advanced and WinCC<br />

Runtime Professional.<br />

WinCC (TIA Portal) is based on the new central engineering<br />

framework Totally Integrated Automation Portal (TIA Portal),<br />

which offers the user a uniform, efficient and intuitive solution<br />

to all automation tasks.<br />

WinCC (TIA Portal) also offers uniform engineering from the<br />

Basic Panel through to the SCADA application.<br />

Together with the <strong>ST</strong>EP 7 (TIA Portal) products,<br />

WinCC (TIA Portal) forms the optimum solution for integrated,<br />

efficient engineering.<br />

Current version:<br />

SIMATIC WinCC V11 Basic<br />

SIMATIC WinCC V11 Comfort<br />

SIMATIC WinCC V11 Advanced<br />

SIMATIC WinCC V11 Professional<br />

■ Benefits<br />

The integrated configuration software reduces training,<br />

maintenance and service overhead and protects the<br />

customer's investments.<br />

Minimized engineering overhead and reduction of lifecycle<br />

costs thanks to Totally Integrated Automation (TIA)<br />

Minimized configuration overhead due to reuse of scalable<br />

and dynamizable objects<br />

Intelligent tools for efficient and simple configuration:<br />

- Wizard for defining the basic structure of the HMI project<br />

- Table-based editors simplify the generation and processing<br />

of similar types of object, e.g. for tags, texts, or alarms<br />

- Complex configuration tasks such as the definition of paths<br />

of motion or the creation of the fundamental operator<br />

prompting are simplified by means of graphical<br />

configuration<br />

Comprehensive support of multi-language configurations for<br />

worldwide use<br />

- Selectable views for entering configuration data in several<br />

languages<br />

- System and user-specific text lexicons<br />

- Export/import of language-dependent texts<br />

Investment protection due to<br />

- Import of the configuration from WinCC flexible 2008 SP2<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Application<br />

HMI Software<br />

HMI software in the TIA Portal<br />

SIMATIC WinCC (TIA Portal) Engineering<br />

SIMATIC WinCC in the editions Basic, Comfort, Advanced and<br />

Professional are innovative engineering tools for configuring<br />

SIMATIC HMI operator panels, as well as for the <strong>PC</strong>-based<br />

visualization systems WinCC Runtime Advanced and WinCC<br />

Runtime Professional.<br />

Depending on the selected product, various target systems can<br />

be configured:<br />

WinCC Basic<br />

Basic Panels<br />

WinCC Comfort<br />

As WinCC Basic, plus:<br />

Comfort Panels<br />

Panels of the 70 series: OP 73, OP 77A, OP 77B<br />

Panels of the 170 series: TP 177A, TP 177B, OP 177B<br />

Panels of the 270 series: TP 277, OP 277<br />

Mobile Panels: Mobile Panel 177, Mobile Panel 277<br />

Multi Panels: MP 177, MP 277, MP 377<br />

WinCC Advanced<br />

As WinCC Comfort, plus:<br />

SIMATIC <strong>PC</strong>s with WinCC Runtime Advanced:<br />

- SIMATIC Panel <strong>PC</strong>: HMI I<strong>PC</strong>277D, Panel <strong>PC</strong> 477B,<br />

HMI I<strong>PC</strong>477C, Panel <strong>PC</strong> 577B, HMI I<strong>PC</strong>577C,<br />

Panel <strong>PC</strong> 677B, HMI I<strong>PC</strong>677C<br />

- SIMATIC Box <strong>PC</strong>: I<strong>PC</strong>227D, Microbox <strong>PC</strong> 427B, I<strong>PC</strong>427C,<br />

Box <strong>PC</strong> 627B, I<strong>PC</strong>627C, Box <strong>PC</strong> 827B, I<strong>PC</strong>827C<br />

- SIMATIC Rack <strong>PC</strong>: Rack <strong>PC</strong> 547B, I<strong>PC</strong>547C, Rack <strong>PC</strong> 647B,<br />

I<strong>PC</strong>647C, Rack <strong>PC</strong> 847B, I<strong>PC</strong>847C<br />

- SIMATIC modular Embedded Controller: EC31<br />

Standard <strong>PC</strong> with WinCC Runtime Advanced<br />

SINUMERIK Panel <strong>PC</strong>: OP010, OP012, OP015, TP015,<br />

OP015A, TP015A<br />

WinCC Professional<br />

As WinCC Advanced, plus:<br />

SIMATIC <strong>PC</strong>s with WinCC Runtime Professional:<br />

- SIMATIC Panel <strong>PC</strong>: HMI I<strong>PC</strong>677C,<br />

- SIMATIC Box <strong>PC</strong>: I<strong>PC</strong>627C, I<strong>PC</strong>827C<br />

- SIMATIC Rack <strong>PC</strong>: I<strong>PC</strong>547C, I<strong>PC</strong>647C, I<strong>PC</strong>847C<br />

Standard <strong>PC</strong> with WinCC Runtime Professional<br />

■ Design<br />

The functionalities of the engineering tools of the SIMATIC<br />

WinCC family are based on each other. The available editors are<br />

largely determined by the respective configurable target<br />

systems and their function. A more comprehensive engineering<br />

tool such as WinCC Advanced can always be used to configure<br />

lower-level target devices as well (e.g. Basic Panels)<br />

A Power Pack can be used to upgrade from a smaller edition to<br />

a larger one. This does not apply to WinCC Basic.<br />

The functionality of WinCC engineering tools already contains<br />

the configuration support of the available Runtime options for<br />

SIMATIC Panels, WinCC Runtime Advanced or WinCC Runtime<br />

Professional, irrespective of the purchased RT licenses.<br />

A separate license is required for the target system when using<br />

the configured Runtime options.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/5<br />

4


4<br />

HMI Software<br />

HMI software in the TIA Portal<br />

SIMATIC WinCC (TIA Portal) Engineering<br />

■ Function<br />

Integration into automation systems<br />

Integration into the SIMATIC Totally Integrated Automation<br />

Portal (TIA Portal)<br />

- Shared data management and uniform symbols via the<br />

controller and HMI<br />

- Optimum interaction between the controller and HMI in a<br />

working environment<br />

- System diagnostics as an integral component<br />

- Shared use of communication settings and process point<br />

definitions<br />

- Simple Drag&Drop of tags in an HMI device, e.g. in a screen<br />

Configuration interface<br />

Intuitive user interfaces with maximum degree of user<br />

friendliness<br />

Comprehensive and fast access to editors and project data<br />

Adaptive user interface of engineering tools depending on<br />

configured target system<br />

User-definable user interface settings, e.g. layout, toolbars<br />

Integrated mass data operations for efficient configuration<br />

Project handling<br />

Device-independent configuration data can be used on a<br />

variety of target systems without the need for conversion.<br />

The interface adapts itself to the functional possibilities of the<br />

target device.<br />

Cross-device utilization of common configuration data<br />

(e.g. alarm classes, text library) in multi-device projects<br />

Wizard-assisted definition of basic structure of HMI projects<br />

(e.g. display layout, operator prompting)<br />

Screen editor with comprehensive options for efficient and fast<br />

screen configuration<br />

Generation of interconnected screen objects via Drag&Drop,<br />

e.g. tags for the creation of input/output fields with process<br />

interfacing or buttons with screen selection function<br />

Definition of screen templates and functions<br />

(comparable with the Slide Master of MS PowerPoint);<br />

footnote: except WinCC RT Professional<br />

User-friendly editor for the creation of faceplates with defined<br />

external interface from screen objects<br />

Graphics-based configuration of motion paths<br />

Layer technology with up to 32 layers<br />

Tools for the Align, Rotate and Mirror functions<br />

Import/export<br />

of tags, links, text lists, and alarms<br />

Tabular editors<br />

Quick and easy generation and modification of configuration<br />

objects of the same type, e.g. tags, texts or messages, in<br />

tabular editors<br />

Intelligent default settings depending on previously<br />

configured data, e.g. automatic incrementing of addresses<br />

when generating consecutive tags<br />

Simple access to the properties of an object without<br />

superfluous user intervention<br />

Simultaneous modification of common object properties<br />

4/6<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Object-based data management with user-friendly search and<br />

edit options<br />

Configuration of alarms and logs directly on the HMI tag, no<br />

switching between different editors<br />

Cross-reference list with direct access to all objects, e.g. for<br />

editing or selection<br />

Search for objects in entire project<br />

Text search and replace functions<br />

Project documentation<br />

Selective project documentation, the following contents can<br />

be printed:<br />

- An entire project<br />

- One or more project-associated devices<br />

- Contents of an editor<br />

- Libraries<br />

Libraries for predefined/user-defined configuration objects<br />

Storage of all configuration objects in the library, e.g. blocks<br />

and even entire screens or tags<br />

Faceplates can be constructed from simple screen objects on<br />

a customer-specific or project-specific basis. Changes to<br />

these faceplates can be made centrally (block definition).<br />

A large number of scalable and dynamizable screen objects<br />

is included in the scope of delivery<br />

Size-scalable graphics for industrial applications are included<br />

in the scope of delivery<br />

Preview function for library objects<br />

Language support<br />

Multilingual project creation (max. 32 languages) in editors<br />

thanks to selectable views<br />

Central management of language-specific texts and graphics<br />

in libraries<br />

Edit, export and import of texts for translation<br />

Language-specific graphics<br />

Visual Basic and C-Script Support<br />

IntelliSense function for fast programming of access to<br />

runtime objects<br />

Simple creation of control sequences in script code<br />

Visual Basic Script debugging in simulator and WinCC<br />

Runtime Advanced and WinCC Runtime Professional<br />

Test and commissioning support<br />

Simulation of HMI projects on engineering <strong>PC</strong><br />

Marking of incomplete or incorrect configuration directly in the<br />

respective editor<br />

Jump to error cause based on alarm messages in the<br />

Compiler<br />

Migration of existing HMI projects<br />

Complete data transfer in projects from WinCC flexible


© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

HMI software in the TIA Portal<br />

SIMATIC WinCC (TIA Portal) Engineering<br />

■ Function (continued)<br />

■ Ordering data Order No.<br />

System prerequisites<br />

WinCC Basic V11 6AV2 100-0AA01-0AA0<br />

WinCC engineering software<br />

Floating license, on DVD<br />

Processor type Pentium M, 1.6 GHz or comparable<br />

incl. license key, includes:<br />

RAM 2 GB<br />

Engineering software for the<br />

configuration and simulation of<br />

Free hard disk space 2 GB on system drive "C:"<br />

Basic Panels<br />

Operating systems Windows XP Home SP3<br />

(only WinCC Basic)<br />

Windows XP Professional SP3 (32 bit)<br />

Windows 7 Home (only WinCC Basic)<br />

Electronic documentation in<br />

English, French, German,<br />

Italian, Spanish, simplified<br />

Chinese, traditional Chinese<br />

Windows 7 Business (32 bit)<br />

WinCC Comfort V11 6AV2 101-0AA01-0AA5<br />

Graphics card<br />

Windows 7 Enterprise (32 bit)<br />

Windows 7 Ultimate (32 bit)<br />

For WinCC Advanced and<br />

WinCC Professional in addition:<br />

- Windows Server 2003 R2<br />

Standard Edition SP2<br />

- Windows Server 2008 Standard Edition<br />

SP2<br />

32 MB RAM, 24 bit color depth<br />

Floating license, on DVD<br />

incl. license key, includes:<br />

Engineering software for the<br />

configuration and simulation of:<br />

Comfort Panels<br />

Multi Panels<br />

Panels<br />

Basic Panels<br />

Electronic documentation in<br />

Screen resolution<br />

Network<br />

1024 x 768 or higher<br />

Ethernet 10 Mbit/s or higher<br />

English, French, German,<br />

Italian, Spanish, simplified<br />

Chinese, traditional Chinese<br />

Optical drive DVD-ROM<br />

WinCC Advanced V11 6AV2 102-0AA01-0AA5<br />

Note:<br />

Floating license, on DVD<br />

Opening several instances of WinCC on your engineering <strong>PC</strong><br />

at the same time may result in more demanding hardware<br />

requirements.<br />

incl. license key, includes:<br />

Engineering software for the<br />

configuration and simulation of:<br />

WinCC Runtime Professional<br />

In addition to WinCC, Windows also requires space on the hard<br />

disk; e.g. free disk space should be available for the swap file.<br />

The following formula has proven itself in the past:<br />

Size of swap file = 3 x size of RAM. For further information, refer<br />

to your Windows documentation<br />

Comfort Panels<br />

Multi Panels<br />

Panels<br />

Basic Panels<br />

Electronic documentation in<br />

English, French, German,<br />

Italian, Spanish, simplified<br />

Chinese, traditional Chinese<br />

WinCC Professional 512<br />

PowerTags V11<br />

Floating license, on DVD<br />

incl. license key, includes:<br />

Engineering software for the<br />

configuration and simulation of:<br />

WinCC Runtime Advanced (with<br />

a maximum of 512 PowerTags)<br />

WinCC Runtime Professional<br />

Comfort Panels<br />

Multi Panels<br />

Panels<br />

Basic Panels<br />

Electronic documentation in<br />

English, French, German,<br />

Italian, Spanish, simplified<br />

Chinese, traditional Chinese<br />

6AV2 103-0DA01-0AA5<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/7<br />

4


4<br />

HMI Software<br />

HMI software in the TIA Portal<br />

SIMATIC WinCC (TIA Portal) Engineering<br />

■ Ordering data Order No. Order No.<br />

WinCC Professional 4096<br />

PowerTags V11<br />

Floating license, on DVD<br />

incl. license key, includes:<br />

Engineering software for the<br />

configuration and simulation of:<br />

WinCC Runtime Advanced (with<br />

a maximum of 4096 PowerTags)<br />

WinCC Runtime Professional<br />

Comfort Panels<br />

Multi Panels<br />

Panels<br />

Basic Panels<br />

Electronic documentation in<br />

English, French, German,<br />

Italian, Spanish, simplified<br />

Chinese, traditional Chinese<br />

WinCC Professional max.<br />

PowerTags V11<br />

Floating license, on DVD<br />

incl. license key, includes:<br />

Engineering software for the<br />

configuration and simulation of:<br />

WinCC Runtime Advanced<br />

(without PowerTags limit)<br />

WinCC Runtime Professional<br />

Comfort Panels<br />

Multi Panels<br />

Panels<br />

Basic Panels<br />

Electronic documentation in<br />

English, French, German,<br />

Italian, Spanish, simplified<br />

Chinese, traditional Chinese<br />

Power Packs<br />

SIMATIC WinCC Engineering<br />

System Power Packs<br />

Single license, license key only<br />

WinCC Comfort to WinCC<br />

Advanced<br />

WinCC Advanced to<br />

WinCC Professional<br />

512 PowerTags<br />

WinCC Professional Power Pack<br />

512 PowerTags to<br />

4096 PowerTags<br />

WinCC Professional Power Pack<br />

4096 PowerTags to<br />

max. PowerTags<br />

■ More information<br />

Further information can be found in the Internet at:<br />

www.siemens.com/tia-portal<br />

4/8<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6AV2 103-0HA01-0AA5<br />

6AV2 103-0XA01-0AA5<br />

6AV2 102-2AA01-0BD5<br />

6AV2 103-2AD01-0AC5<br />

6AV2 103-2DH01-0BD5<br />

6AV2 103-2HX01-0BD5<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Software Update Service<br />

For a period of 12 months and for<br />

a fixed price, the customer is<br />

automatically provided with all<br />

upgrades and service packs for<br />

each installed WinCC<br />

engineering system or option. The<br />

contract is automatically<br />

extended by a further year unless<br />

canceled up to 12 weeks prior to<br />

expiration.<br />

Software Update Service<br />

(Standard Edition)<br />

The delivery is implemented<br />

according to the number of<br />

ordered SUS products<br />

(e.g. 10 upgrade packages with<br />

10 DVDs, 10 USB flash drives,<br />

etc.)<br />

WinCC Comfort D 6AV6 612-0AA00-0AL0<br />

WinCC Advanced D 6AV6 613-0AA00-0AL0<br />

WinCC Professional<br />

512 PowerTags<br />

6AV2 103-0DA00-0AL0<br />

WinCC Professional<br />

4096 PowerTags<br />

6AV2 103-0HA00-0AL0<br />

WinCC Professional<br />

max. PowerTags<br />

Software Update Service<br />

(Compact Edition)<br />

The delivery items are combined.<br />

For several contracts, only<br />

1 package with 1 data medium<br />

set, 1 USB flash drive with the<br />

corresponding number of<br />

licenses and the corresponding<br />

number of COLs will be supplied.<br />

The delivery items to be<br />

combined must be ordered as<br />

one item.<br />

6AV2 103-0XA00-0AL0<br />

WinCC Comfort D 6AV6 612-0AA00-0AM0<br />

WinCC Advanced D 6AV6 613-0AA00-0AM0<br />

WinCC Professional<br />

512 PowerTags<br />

6AV2 103-0DA00-0AM0<br />

WinCC Professional<br />

4096 PowerTags<br />

6AV2 103-0HA00-0AM0<br />

WinCC Professional<br />

max. PowerTags<br />

Upgrades<br />

SIMATIC WinCC flexible to<br />

SIMATIC WinCC (TIA Portal)<br />

6AV2 103-0XA00-0AM0<br />

WinCC flexible 2008 Compact to<br />

WinCC Comfort V11<br />

6AV2 101-4AB01-0AE5<br />

WinCC flexible 2008 Standard to<br />

WinCC Comfort V11<br />

6AV2 101-4BB01-0AE5<br />

WinCC flexible 2008 Advanced<br />

to WinCC Advanced V11<br />

6AV2 102-4AA01-0AE5


■ Overview<br />

SIMATIC WinCC Runtime Advanced visualization software<br />

<strong>PC</strong>-based HMI solution for single-user systems directly at the<br />

machine<br />

Basic package for visualization, reporting and logging, user<br />

administration, can be expanded flexibly with VB scripts<br />

Basic package expandable by means of option packages<br />

Can be integrated into automation solutions based on TCP/IP<br />

networks<br />

Expanded service concepts with remote operation,<br />

diagnostics and administration over the intranet and Internet<br />

in combination with email communication<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) Runtime<br />

SIMATIC WinCC (TIA Portal) Runtime<br />

SIMATIC WinCC Runtime Professional<br />

visualization software<br />

<strong>PC</strong>-based operator control and monitoring system for<br />

visualization and operator control of processes, production<br />

flows, machines and plants in all sectors – from the simple<br />

single-user station through to distributed multi-user systems<br />

and cross-location solutions with web clients. WinCC Runtime<br />

Professional is the information hub for corporation-wide<br />

vertical integration.<br />

Industry-standard functions for signaling and acknowledging<br />

events, archiving of messages and measured values, logging<br />

of all process and configuration data, user administration, can<br />

be expanded flexibly with VB and C scripts<br />

Basic package expandable by means of option packages<br />

Also included are APIs for the Runtime to utilize the open<br />

programming interfaces<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/9<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) Runtime<br />

WinCC Runtime Advanced<br />

■ Overview<br />

<strong>PC</strong>-based HMI solution for single-user systems directly at the<br />

machine. SIMATIC WinCC Runtime Advanced is configured with<br />

the SIMATIC WinCC Advanced or SIMATIC WinCC Professional<br />

configuration software.<br />

■ Benefits<br />

Functions for all visualization tasks:<br />

- Operator functions<br />

- Graphics and trend displays<br />

- Alarm logging<br />

- Report system<br />

- Archiving (option)<br />

- Recipe management (option)<br />

- Audit Trail (option)<br />

Flexible runtime functionality due to Visual Basic scripts<br />

Innovative service concepts with remote operation,<br />

diagnostics and administration via Intranet and Internet as<br />

well as e-mail communication to increase availability (option)<br />

Support for simple distributed automation solutions based on<br />

TCP/IP networks at the machine level (option)<br />

Part of Totally Integrated Automation<br />

- Direct access to the tag and message configuration of the<br />

SIMATIC controller<br />

- Integrated diagnostic functions for increasing productivity<br />

■ Application<br />

SIMATIC WinCC Runtime Advanced is the high-performance<br />

visualization software for simple, machine-oriented visualization<br />

tasks. It can be used as a single-user solution for all automation<br />

applications in production automation, process automation and<br />

building services automation.<br />

SIMATIC WinCC Runtime Advanced can be used in combination<br />

with the following operator panels:<br />

SIMATIC Panel <strong>PC</strong>: HMI I<strong>PC</strong>277D, Panel <strong>PC</strong> 477B,<br />

HMI I<strong>PC</strong>477C, Panel <strong>PC</strong> 577B, HMI I<strong>PC</strong>577C, Panel <strong>PC</strong> 677B,<br />

HMI I<strong>PC</strong>677C<br />

SIMATIC Box <strong>PC</strong>: I<strong>PC</strong>227D, Microbox <strong>PC</strong> 427B, I<strong>PC</strong>427C,<br />

Box <strong>PC</strong> 627B, I<strong>PC</strong>627C, Box <strong>PC</strong> 827B, I<strong>PC</strong>827C<br />

SIMATIC Rack <strong>PC</strong>: Rack <strong>PC</strong> 547B, I<strong>PC</strong>547C, Rack <strong>PC</strong> 647B,<br />

I<strong>PC</strong>647C, Rack <strong>PC</strong> 847B, I<strong>PC</strong>847C<br />

SIMATIC modular Embedded Controller: EC31<br />

SINUMERIK Panel <strong>PC</strong>: OP010, OP012, OP015, TP015,<br />

OP015A, TP015A<br />

Standard <strong>PC</strong>s with resolutions (W x H in pixels) of:<br />

- 4:3 format: 640 x 4<strong>80</strong>, <strong>80</strong>0 x 600, 1024 x 768, 12<strong>80</strong> x 1024,<br />

1600 x 1200<br />

- Widescreen format: 1440 x 900, 16<strong>80</strong> x 1050, 1920 x 10<strong>80</strong>,<br />

1920 x 1200<br />

4/10<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Design<br />

SIMATIC WinCC Runtime Advanced is available as a software<br />

package with 128, 512, 2048 or 4096 PowerTags. The term<br />

PowerTags is used exclusively to identify process variables and<br />

area pointers that have a process link to the controller. Variables<br />

without process link, constant limit values of variables, and<br />

messages (up to 4000 bit-triggered messages) are also<br />

available for additional system performance. The range of<br />

functions of WinCC Runtime Advanced includes the centralized<br />

HMI components for visualizing and reporting, and it can be<br />

expanded to suit requirements and costs by using optional<br />

packages.<br />

SIMATIC WinCC Runtime Advanced is configured with the<br />

SIMATIC WinCC Advanced configuration software.<br />

■ Function<br />

Visualization via Windows-compliant user interface<br />

Made up of parameterizable screen objects and faceplates<br />

created on a project-specific basis:<br />

Numeric and alphanumeric input/output fields<br />

Static text and graphic display plus vector graphics<br />

Dynamizable graphics from HMI symbol library<br />

Bar graph, trend curve graph with scroll and zoom function as<br />

well as read line<br />

Signal-specific text and graphic lists<br />

Buttons and switches for operator-process communication<br />

Editing fields for process values (signals)<br />

Analog display, slider as example for further screen objects<br />

Project-specific faceplates created from basic objects of the<br />

system<br />

Graphic displays for various standard graphic formats, e.g.<br />

bitmaps, .jpg, .wmf<br />

Alarms and messages<br />

Discrete alarms and analog alarms as well as event-driven<br />

Alarm-S/Alarm-D message procedure with SIMATIC S7<br />

Freely-definable alarm classes for definition of<br />

acknowledgment response and display of alarm events<br />

Logging of alarms and process values 1)<br />

Logging in files (e.g. CSV or TXT file) and Microsoft SQL<br />

databases<br />

Online evaluation of process value and alarm logs<br />

Evaluation of process value and alarm logs using standard<br />

Microsoft tools such as Excel<br />

Recipes 1)<br />

Generation of data records for machine data or production<br />

data<br />

Display or entry of data records via a configurable screen<br />

object or via process screens distributed within the project<br />

Transmission of data records from or to the controller<br />

Import/export of data records from/to CSV files for further<br />

processing with other tools (e.g. MS Excel)<br />

1) Option for SIMATIC WinCC Runtime Advanced, runtime licenses<br />

must be purchased separately. For further information, refer to<br />

"WinCC options".


■ Function (continued)<br />

Documentation of process data, alarm events, and recipes<br />

Time or event-driven report output<br />

User-definable layout<br />

Flexible expansion of integrated system function using Visual<br />

Basic script<br />

Language support for multilingual projects<br />

Up to 32 online languages<br />

Language-dependent texts and graphics<br />

Language selection during runtime<br />

User-oriented access protection according to requirements of<br />

regulated sectors<br />

Authentication with user ID and password<br />

User group-specific rights<br />

Central system-wide user administration based on SIMATIC<br />

Logon 1)<br />

Monitoring of changes by operators in runtime operation 1)<br />

Recording of operator actions in an Audit Trail 1)<br />

Onboard controller connection to many different controllers<br />

Communication via native drivers and standard O<strong>PC</strong> channel<br />

Simultaneous connection using several protocols: O<strong>PC</strong> Client<br />

and SIMATIC HMI HTTP protocol are additive, i.e. they can be<br />

used in conjunction with other controller connections<br />

Open communication between HMI systems and with higherlevel<br />

systems<br />

O<strong>PC</strong> server<br />

- Use of the visualization system as a data server<br />

(O<strong>PC</strong> Server) for higher-level automation components,<br />

e.g. control systems or systems in the office area<br />

- O<strong>PC</strong>-DA-Server: tags, e.g. process values<br />

Communication between HMI systems is established on the<br />

basis of Ethernet networks, or via the Intranet/Internet<br />

- Read and write access to tags. The WinCC Runtime<br />

Advanced or SIMATIC Panels provide other SIMATIC HMI<br />

systems or office applications with data (variables)<br />

Sending of e-mails on demand or event-driven<br />

- e.g. to maintenance personnel via SMTP server (Simple Mail<br />

Transfer Protocol)<br />

- The optional use of e-mail/SMS gateways enables access to<br />

standard networks (external service provider required)<br />

System diagnostics via device-specific HTML pages; the<br />

following functions are available:<br />

- Starting and stopping the HMI runtime for maintenance<br />

- Remote access to recipe data records, passwords and<br />

information specific to the HMI system<br />

- Access to the HMI system files via a file explorer<br />

- Download of configuration data via the Intranet/Internet<br />

- Supplement with own HTML pages<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) Runtime<br />

WinCC Runtime Advanced<br />

WinCC Sm@rtServer<br />

for the remote control via the Intranet and Internet 1)<br />

Display and control of process screens on remote <strong>PC</strong> or Panel<br />

A SIMATIC HMI system can be used to control or monitor<br />

another system remotely; entry level for client/server<br />

configurations for distributed operator stations or for solutions<br />

with head end or control room<br />

WinCC ControlDevelopment<br />

for extending the functionality by adding own Controls 1)<br />

Development of proprietary VB.net or C# Controls for<br />

integration in SIMATIC WinCC Runtime Advanced<br />

1) Option for SIMATIC WinCC Runtime Advanced, runtime licenses<br />

must be purchased separately. For further information, refer to<br />

"WinCC options".<br />

System prerequisites<br />

SIMATIC WinCC Runtime<br />

Advanced<br />

Processor type 1) Pentium M, 1.6 GHz or comparable<br />

RAM 2) 2 GB<br />

Free hard disk space 3) 2 GB on system drive "C:"<br />

Operating systems Windows XP Professional SP3<br />

(32 bit)<br />

Windows XP Embedded 4)<br />

Windows 7 Business (32 bit)<br />

Windows 7 Enterprise (32 bit)<br />

Windows 7 Ultimate (32 bit)<br />

Windows 7 Embedded StdE 7<br />

(32 bit) 4)<br />

Windows Server 2003 R2<br />

Standard Edition SP2<br />

Windows Server 2008 Standard<br />

Edition SP2<br />

Graphics card 32 MB RAM, 24 bit color depth<br />

Screen resolution 4:3 format:<br />

640 x 4<strong>80</strong>, <strong>80</strong>0 x 600, 1024 x 768,<br />

12<strong>80</strong> x 1024, 1600 x 1200<br />

Widescreen format:<br />

1440 x 900, 16<strong>80</strong> x 1050,<br />

1920 x 10<strong>80</strong>, 1920 x 1200<br />

Network Ethernet 10 Mbit/s or higher<br />

Optical drive DVD-ROM<br />

1) In combination with options, more powerful systems may be required.<br />

2) The required RAM is determined primarily by the size of the graphics<br />

used.<br />

3) Without taking archives into account.<br />

4) Only for enabled platforms (e.g. Panel <strong>PC</strong> 477). You can get information<br />

from your <strong>Siemens</strong> contact.<br />

Note:<br />

In addition to the space needed by WinCC, Windows also<br />

requires space on the hard disk; e.g. for the swap file.<br />

The following formula has proven itself in the past:<br />

Size of swap file = 3 x size of RAM.<br />

For further information, refer to your Windows documentation.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/11<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) Runtime<br />

WinCC Runtime Advanced<br />

■ Technical specifications<br />

The following tables of system limitations provide assistance in<br />

estimating whether a specific project is still within the system<br />

limitations for WinCC Runtime Advanced. The stated maximum<br />

values are not additive. We cannot guarantee proper functioning<br />

of configurations that make full use of all system limits on the<br />

HMI devices. In addition to the limitations specified, allowances<br />

must be made for restrictions in configuration memory<br />

resources.<br />

SIMATIC WinCC Runtime<br />

Advanced<br />

Tags<br />

Number of tags in the project 6,144<br />

Number of PowerTags 128 –4,096<br />

Number of elements per array 1,600<br />

Number of local tags<br />

Alarms<br />

2,048<br />

Number of alarm classes 32<br />

Number of discrete alarms 4,000<br />

Number of analog alarms 500<br />

Length of an alarm in characters <strong>80</strong><br />

Number of process values<br />

per alarm<br />

8<br />

Size of the alarm buffer 1,024<br />

Number of queued alarm events<br />

Screens<br />

500<br />

Number of screens 500<br />

Number of fields per screen 400<br />

Number of tags per screen 400<br />

Number of complex objects<br />

per screen 1)<br />

Recipes<br />

40<br />

Number of recipes 999<br />

Number of elements per recipe 2) 2,000<br />

User data length in KB<br />

per data record<br />

256<br />

Number of data records per recipe<br />

Logs<br />

5,000<br />

Number of logs 100<br />

Number of entries per log<br />

(including all log segments) 3)<br />

500,000<br />

Number of log segments 400<br />

Cyclical trigger for tag logging 1 s<br />

Number of tags that can be logged<br />

per log<br />

6,144<br />

4/12<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC WinCC Runtime<br />

Advanced<br />

Trends<br />

Number of trends <strong>80</strong>0<br />

Text lists and graphics lists<br />

Number of graphic lists 500<br />

Number of text lists 500<br />

Number of entries per text or 3,500<br />

graphic list<br />

Number of graphic objects 2,000<br />

Number of text elements 30,000<br />

Scripts<br />

Number of scripts 200<br />

Communication<br />

Number of connections 8<br />

Number of connections based on 16<br />

"SIMATIC HMI HTTP"<br />

Maximum number of connected 4<br />

Sm@rtClients (including a service<br />

client)<br />

4)<br />

Help system<br />

Number of characters in a help text 320<br />

Languages<br />

Number of runtime languages 32<br />

Scheduler<br />

Time-triggered tasks 5) 48<br />

User administration<br />

Number of user groups 50<br />

Number of user rights 32<br />

Number of users 100<br />

1) Complex objects are: Bars, sliders, symbol library, clock, and all<br />

objects from the Controls area.<br />

2) When using arrays, each array element represents a recipe element.<br />

3) For the "segmented circular log" logging method, the number of<br />

entries for all sequence logs is valid. The product derived from the<br />

number of circular logs times the number of data records in this log<br />

may not be exceeded.<br />

4) Up to three Sm@rtClients can interconnect with the Sm@rtServer on<br />

Panel <strong>PC</strong> 477.<br />

5) Event-triggered tasks are not relevant for the system limits.


HMI Software<br />

SIMATIC WinCC (TIA Portal) Runtime<br />

■ Ordering data Order No. Order No.<br />

SIMATIC WinCC Runtime<br />

Advanced<br />

for <strong>PC</strong> systems; incl. SW for<br />

options 1) Single license, on<br />

CD-ROM incl. licensing, for:<br />

128 PowerTags (RT 128) 6AV2 104-0BA01-0AA0<br />

512 PowerTags (RT 512) 6AV2 104-0DA01-0AA0<br />

2048 PowerTags (RT 2048) 6AV2 104-0FA01-0AA0<br />

4096 PowerTags (RT 4096) 6AV2 104-0HA01-0AA0<br />

Power Packs<br />

SIMATIC WinCC Runtime<br />

Advanced<br />

Single license, only license key<br />

for PowerTags, from<br />

128 to 512 PowerTags 6AV2 104-2BD01-0BD0<br />

512 to 2048 PowerTags 6AV2 104-2DF01-0BD0<br />

2048 to 4096 PowerTags 6AV2 104-2FH01-0BD0<br />

SIMATIC WinCC Runtime<br />

Advanced to SIMATIC WinCC<br />

Runtime Professional<br />

WinCC Runtime Advanced 6AV2 105-2BB01-0AC0<br />

128 PowerTags to WinCC<br />

Runtime Professional<br />

128 PowerTags<br />

WinCC Runtime Advanced 6AV2 105-2DD01-0AC0<br />

512 PowerTags to WinCC<br />

Runtime Professional<br />

512 PowerTags<br />

WinCC Runtime Advanced 6AV2 105-2FF01-0AC0<br />

2048 PowerTags to WinCC<br />

Runtime Professional<br />

2048 PowerTags<br />

WinCC Runtime Advanced 6AV2 105-2HH01-0AC0<br />

4096 PowerTags to WinCC<br />

Runtime Professional<br />

4096 PowerTags<br />

SIMATIC WinCC Runtime<br />

Advanced to SIMATIC WinCC<br />

Runtime Professional ASIA<br />

WinCC Runtime Advanced<br />

128 PowerTags to WinCC<br />

Runtime Professional<br />

128 PowerTags ASIA<br />

WinCC Runtime Advanced<br />

512 PowerTags to WinCC<br />

Runtime Professional<br />

512 PowerTags ASIA<br />

WinCC Runtime Advanced<br />

2048 PowerTags to WinCC<br />

Runtime Professional<br />

2048 PowerTags ASIA<br />

WinCC Runtime Advanced<br />

4096 PowerTags to WinCC<br />

Runtime Professional<br />

4096 PowerTags ASIA<br />

6AV2 105-2BB11-0AC0<br />

6AV2 105-2DD11-0AC0<br />

6AV2 105-2FF11-0AC0<br />

6AV2 105-2HH11-0AC0<br />

1) Runtime licenses for WinCC flexible Runtime options must be<br />

purchased separately for each target system.<br />

2) Each including a single license WinCC flexible /Archives and<br />

WinCC flexible /Recipes<br />

■ More information<br />

Further information can be found in the Internet at:<br />

www.siemens.com/tia-portal<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Upgrades<br />

SIMATIC WinCC flexible 2008 to<br />

SIMATIC WinCC Runtime<br />

Advanced V11<br />

WinCC flexible 2008 Runtime<br />

128 PowerTags to WinCC<br />

Runtime Advanced<br />

128 PowerTags 2)<br />

WinCC flexible 2008 Runtime<br />

512 PowerTags to WinCC<br />

Runtime Advanced<br />

512 PowerTags 2)<br />

WinCC flexible 2008 Runtime<br />

2048 PowerTags to WinCC<br />

Runtime Advanced<br />

2048 PowerTags 2)<br />

WinCC flexible 2008 Runtime<br />

4096 PowerTags to WinCC<br />

Runtime Advanced<br />

4096 PowerTags 2)<br />

SIMATIC WinCC flexible Panel<br />

options to SIMATIC WinCC V11<br />

Panel options<br />

WinCC flexible /Audit for<br />

SIMATIC Panels to SIMATIC<br />

WinCC Audit for SIMATIC Panels<br />

WinCC flexible /Sm@rtAccess<br />

for SIMATIC Panels to SIMATIC<br />

WinCC Sm@rtServer for<br />

SIMATIC Panels<br />

WinCC flexible /Sm@rtService<br />

for SIMATIC Panels to SIMATIC<br />

WinCC Sm@rtServer for<br />

SIMATIC Panels<br />

WinCC Runtime Advanced<br />

6AV2 104-4BB01-0AE0<br />

6AV2 104-4DD01-0AE0<br />

6AV2 104-4FF01-0AE0<br />

6AV2 104-4HH01-0AE0<br />

6AV2 107-4XP00-0BF0<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/13<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) Runtime<br />

WinCC Runtime Professional<br />

■ Overview<br />

<strong>PC</strong>-based operator control and monitoring system for visualization<br />

and operator control of processes, production flows,<br />

machines and plants in all sectors – from the simple single-user<br />

station through to distributed multi-user systems and crosslocation<br />

solutions with web clients.<br />

SIMATIC WinCC Runtime Professional is the information hub for<br />

corporation-wide vertical integration. SIMATIC WinCC Runtime<br />

Professional is configured with the SIMATIC WinCC Professional<br />

configuration software.<br />

■ Benefits<br />

Functions for all visualization tasks:<br />

- Operator functions<br />

- Graphic and trend displays<br />

- Alarm logging<br />

- Report system<br />

- Archiving (option)<br />

- Recipe management (option)<br />

Universally scalable<br />

- Expandable from single station to client-server<br />

configurations<br />

- Process visualization via the web with the WinCC<br />

WebNavigator<br />

Open standards for easy integration<br />

- Efficient real-time database MS SQL Server<br />

- Open for application modules with ActiveX controls<br />

- Visual Basic for Applications for individual expansions<br />

- O<strong>PC</strong> for cross-vendor communication<br />

Part of Totally Integrated Automation<br />

- Direct access to the tag and message configuration of the<br />

SIMATIC controller<br />

- Integrated diagnostic functions for increasing productivity<br />

■ Application<br />

SIMATIC WinCC Runtime Professional is designed for visualization<br />

and operation of processes, manufacturing cycles,<br />

machines and plants. With its powerful process interface,<br />

especially to the SIMATIC family, and the secure data logging,<br />

WinCC Runtime Professional enables solutions for the process<br />

control.<br />

The sector-neutral basic system enables universal usage in all<br />

automation applications.<br />

SIMATIC WinCC Runtime Professional can be used in combination<br />

with the following operator panels:<br />

SIMATIC <strong>PC</strong>s:<br />

SIMATIC Panel <strong>PC</strong>: HMI I<strong>PC</strong>677C,<br />

SIMATIC Box <strong>PC</strong>: I<strong>PC</strong>627C, I<strong>PC</strong>827C<br />

SIMATIC Rack <strong>PC</strong>: I<strong>PC</strong>547C, I<strong>PC</strong>647C, I<strong>PC</strong>847C<br />

Standard <strong>PC</strong><br />

4/14<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Design<br />

SIMATIC WinCC Runtime Professional is available as a software<br />

package with 128, 512, 2048, 4096, 8192, 65536 PowerTags.<br />

PowerTags are data points that are connected to controllers or<br />

other data sources via a WinCC Runtime Professional channel.<br />

Up to 32 alarms can be obtained from one data point. Moreover,<br />

internal tags without coupling are available for additional system<br />

performance. WinCC Runtime Professional also contains<br />

500 archive tags. Additional archive licenses can be obtained<br />

for greater quantity structures.<br />

Licenses for a multi-user configuration<br />

The system software with the required number of PowerTags and<br />

additionally the SIMATIC WinCC Server for Runtime Professional<br />

option must be installed on the server. For the clients in the basic<br />

configuration, a SIMATIC WinCC Client for Runtime Professional<br />

license is sufficient.<br />

■ Function<br />

Visualization via Windows-compliant user interface<br />

Made up of parameterizable screen objects and faceplates<br />

created on a project-specific basis:<br />

Numeric and alphanumeric input/output fields<br />

Static text and graphic display plus vector graphics<br />

Dynamizable graphics from HMI symbol library<br />

Bar graph, trend curve graph with scroll and zoom function as<br />

well as read line<br />

Signal-specific text and graphic lists<br />

Buttons and switches for operator-process communication<br />

Editing fields for process values (signals)<br />

Analog display, slider as example for further screen objects<br />

Project-specific faceplates created from basic objects of the<br />

system<br />

Graphic displays for various standard graphic formats, e.g.<br />

bitmaps, .jpg, .wmf<br />

Alarms and messages<br />

Discrete alarms and analog alarms as well as event-driven<br />

Alarm-S/Alarm-D message procedure with SIMATIC S7<br />

Freely-definable alarm classes for definition of<br />

acknowledgment response and display of alarm events<br />

Logging of alarms and process values 1)<br />

Signaling system for detecting and archiving events with<br />

display and control options according to DIN 19235<br />

Process logging for the acquisition, compression and storage<br />

of measured values<br />

Online evaluation of process value and alarm logs


■ Function (continued)<br />

Recipes 1)<br />

Generation of data records for machine data or production<br />

data<br />

Display or entry of data records via a configurable screen<br />

object or via process screens distributed within the project<br />

Transmission of data records from or to the controller<br />

Import/export of data records for further processing with other<br />

tools (e.g. MS Excel)<br />

Documentation of process data, alarm events, and recipes<br />

Time or event-driven report output<br />

User-definable layout<br />

Flexible expansion by means of Visual Basic Script and ANSI-C<br />

Programming interfaces for individual access to data<br />

and functions of WinCC Runtime Professional and for<br />

the integration in user programs with VBA, VB Script,<br />

C-API, C-Script (ANSI-C)<br />

Language support for multilingual projects<br />

Language-dependent texts and graphics<br />

Language selection during runtime<br />

Onboard controller connection to many different controllers<br />

Communication via native drivers and standard O<strong>PC</strong> channel<br />

For communication with subordinate controls<br />

(SIMATIC protocols, PROFIBUS DP, PROFIBUS FMS,<br />

DDE and O<strong>PC</strong> server included in the scope of delivery)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) Runtime<br />

WinCC Runtime Professional<br />

Open communication between HMI systems and with higherlevel<br />

systems<br />

O<strong>PC</strong>-Server<br />

Use of the visualization system as a data server (O<strong>PC</strong>-Server)<br />

for higher-level automation components such as control<br />

systems or systems in the office sector<br />

- O<strong>PC</strong>-DA-Server: tags, e.g. process values<br />

- O<strong>PC</strong>-HDA-Server: logged process values<br />

- O<strong>PC</strong>-A&E-Server: Alarms<br />

- O<strong>PC</strong>-XML-DA-Server: tags, e.g. process values<br />

OLE DB Server<br />

- Standardized and user-friendly access to WinCC log data<br />

(MS SQL Server 2005).<br />

- Access is via the OLE-DB Provider supplies all WinCC log<br />

data available along with the accompanying process values,<br />

as well as alarm and user texts.<br />

- The WinCC OLE-DB provider also supports analysis<br />

functions such as minimum, maximum, alarm hit list, etc.<br />

WinCC WebNavigator for Runtime Professional 1)<br />

- Option for SIMATIC WinCC Runtime Professional for<br />

operating and monitoring plants over the Internet, company<br />

Intranet or LAN.<br />

- Configuration from a web server with the SIMATIC WinCC<br />

Runtime Professional software as a single-user, client or<br />

server version and a web client that enables operator control<br />

and monitoring of a current WinCC Runtime Professional<br />

project via an Internet browser with ActiveX support. The<br />

WinCC basic system does not have to be installed on the<br />

client computer.<br />

WinCC DataMonitor for Runtime Professional 1)<br />

- The WinCC DataMonitor is used for displaying and<br />

evaluating current process states and historical data on<br />

office <strong>PC</strong>s using standard tools such as Microsoft Internet<br />

Explorer or Microsoft Excel. The DataMonitor Client is<br />

supported by a web server with current and historic process<br />

data and alarms. All staff ranging from machine operators to<br />

corporate managers can use the DataMonitor to obtain<br />

information.<br />

WinCC ControlDevelopment<br />

for extending the functionality by adding own Controls 1)<br />

Development of proprietary VB.net or C# Controls for<br />

integration in WinCC Runtime Professional<br />

1) Option for SIMATIC WinCC Runtime Professional; runtime licenses<br />

must be purchased separately. For further information, refer to<br />

"WinCC options".<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/15<br />

4


HMI Software<br />

SIMATIC WinCC (TIA Portal) Runtime<br />

WinCC Runtime Professional<br />

■ Function (continued)<br />

System prerequisites SIMATIC WinCC Runtime<br />

Professional<br />

Processor type 1) Pentium M, 1.6 GHz or comparable<br />

RAM 2) 2 GB<br />

Free hard disk space 3) 2 GB on system drive "C:"<br />

Operating systems Windows XP Professional SP3 (32 bit)<br />

Windows XP Embedded 4)<br />

Windows 7 Business (32 bit)<br />

Windows 7 Enterprise (32 bit)<br />

Windows 7 Ultimate (32 bit)<br />

Windows 7 Embedded<br />

StdE 7 (32 bit) 4)<br />

Windows Server 2003 R2<br />

Standard Edition SP2<br />

Windows Server 2008<br />

Standard Edition SP2<br />

Graphics card 32 MB RAM, 24 bit color depth<br />

Screen resolution 4:3 format:<br />

640 x 4<strong>80</strong>, <strong>80</strong>0 x 600, 1024 x 768,<br />

12<strong>80</strong> x 1024, 1600 x 1200<br />

Widescreen format:<br />

1440 x 900, 16<strong>80</strong> x 1050, 1920 x 10<strong>80</strong>,<br />

1920 x 1200<br />

Network Ethernet 10 Mbit/s or higher<br />

Optical drive DVD-ROM<br />

4 1) In combination with options, more powerful systems may be required<br />

2) The required RAM is determined primarily by the size of the graphics<br />

used.<br />

3) Without taking archives into account.<br />

4) Only for enabled platforms (e.g. Panel <strong>PC</strong> 477). You can get information<br />

from your <strong>Siemens</strong> contact.<br />

Note:<br />

In addition to WinCC, Windows also requires space on the hard<br />

disk; e.g. free disk space should be available for the swap file.<br />

The following formula has proven itself in the past: Size of swap<br />

file = 3 x size of RAM. For further information, refer to your<br />

Windows documentation.<br />

4/16<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Integration<br />

Integration in company-wide solutions<br />

(IT and business integration)<br />

WinCC Runtime Professional is strictly based on Microsoft<br />

technology, which provides for the greatest possible compatibility<br />

and integration ability. ActiveX and .net Controls support<br />

technology and sector-specific expansions. Cross-manufacturer<br />

communication is also a simply exercise. The reason: WinCC<br />

Runtime Professional can be used as an O<strong>PC</strong> client and server,<br />

and in addition to access to current process values, it also<br />

supports standards such as O<strong>PC</strong> HDA (Historical Data Access),<br />

O<strong>PC</strong> Alarm & Events, and O<strong>PC</strong> XML Data Access. Just as<br />

important: Visual Basic Scripting (VBS) as an easy-to-learn,<br />

open Runtime language. If desired, professional application<br />

developers can also use ANSI-C.<br />

WinCC Runtime Professional integrates a powerful and scalable<br />

Historian function based on the Microsoft SQL Server in the<br />

basic system. Thus the user is given all possibilities:<br />

from high-performance archiving of current process data, to<br />

long-term archiving with high data compression, through to a<br />

central information turntable in form of a company-wide Process<br />

Historian. Open interfaces form the basis for an effective IT and<br />

business integration.


■ Technical specifications<br />

The following tables of system limitations provide assistance in<br />

estimating whether a specific project is still within the system<br />

limitations for WinCC Runtime Advanced. The stated maximum<br />

values are not additive.<br />

We cannot guarantee proper functioning of configurations that<br />

make full use of all system limits on the HMI devices.<br />

In addition to the limitations specified, allowances must be made<br />

for restrictions in configuration memory resources.<br />

SIMATIC WinCC Runtime<br />

Professional<br />

Alarms<br />

Configurable alarms per server/<br />

single user<br />

150,000<br />

PowerTags per alarm line 10<br />

User text blocks per alarm line 10<br />

Alarm classes (incl. system alarm<br />

classes)<br />

18<br />

Alarm types 16<br />

Alarm priorities<br />

Alarms in Runtime<br />

17 (0...16)<br />

Alarms per alarm log Unlimited 1)<br />

Alarms per short-term log list 1,000<br />

Alarms per long-term log list 1,000 2)<br />

Alarms per alarm display 5,000 3)<br />

Screens<br />

Objects per screen 4) Unlimited 5)<br />

Levels per screen 32<br />

Screens per project Unlimited 5)<br />

Instances of fixed faceplates in a 31 instances of the same picture<br />

process screen<br />

type<br />

Screen size in pixels 10,000 x 10,000<br />

Nesting levels of screen objects 20<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) Runtime<br />

WinCC Runtime Professional<br />

Recipes<br />

Number of recipes Unlimited 5)<br />

Number of recipe elements 500 6)<br />

Number of recipe data records 3,000 6)<br />

Number of views Unlimited 5)<br />

SIMATIC WinCC Runtime<br />

Professional<br />

Logs<br />

Trend views per screen 25<br />

Trends per trend view <strong>80</strong><br />

Tables per screen 25<br />

Columns per table 12<br />

Values per table 30,000<br />

Logs per single-user station/server 100<br />

Log tags per single-user station/<br />

server 7)<br />

Trends<br />

<strong>80</strong>,000<br />

Trend views per image 25<br />

Trends per trend view<br />

User administration<br />

<strong>80</strong><br />

Number of user groups 128<br />

Number of user rights 999<br />

Number of users<br />

Configurations – Quantity<br />

structure in a multi-user system<br />

128<br />

WinCC clients in a system 32 8) 9)<br />

Web clients in a system 50 10)<br />

1) Limited by system resources.<br />

2) On single-user station or server or on client per server if<br />

"LongTimeArchiveConsistency" is set to "No". On single-user station,<br />

server, or client if "LongTimeArchiveConsistency" is set to "Yes".<br />

3) On single-user station or server or on client per server.<br />

4) The number and complexity of the objects affect the performance.<br />

5) Limited by system resources.<br />

6) The sum of the number of recipe elements and number of data<br />

records must not exceed a value of 320,000.<br />

7) Dependent on the Logging Power Pack used for the log tags.<br />

500 log tags are contained in the basis version.<br />

8) If the server is also used as an operating unit, the number of clients for<br />

this server is reduced to four.<br />

9) Mixed configuration: 32 Clients + 3 Web Clients<br />

10) Mixed configuration: 50 Web Clients + 1 WinCC Client<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/17<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) Runtime<br />

WinCC Runtime Professional<br />

■ Ordering data Order No. Order No.<br />

SIMATIC WinCC Runtime<br />

Professional<br />

For <strong>PC</strong> systems; incl. SW of the<br />

options 1) ,<br />

language/font versions: Ge, En,<br />

Fr, It, Sp<br />

Single License,<br />

on DVD incl. licensing, for:<br />

128 PowerTags 6AV2 105-0BA01-0AA0<br />

512 PowerTags 6AV2 105-0DA01-0AA0<br />

2048 PowerTags 6AV2 105-0FA01-0AA0<br />

4096 PowerTags 6AV2 105-0HA01-0AA0<br />

8192 PowerTags 6AV2 105-0KA01-0AA0<br />

65536 PowerTags 6AV2 105-0MA01-0AA0<br />

Incl. 500 archive tags each<br />

SIMATIC WinCC Runtime<br />

Professional ASIA<br />

For <strong>PC</strong> systems; incl. SW of the<br />

options 1) ,<br />

language/font versions: En, Chs,<br />

Cht, Kor, Jpn<br />

Single License,<br />

on DVD incl. licensing, for:<br />

128 PowerTags 6AV2 105-0BA11-0AA0<br />

512 PowerTags 6AV2 105-0DA11-0AA0<br />

2048 PowerTags 6AV2 105-0FA11-0AA0<br />

4096 PowerTags 6AV2 105-0HA11-0AA0<br />

8192 PowerTags 6AV2 105-0KA11-0AA0<br />

65536 PowerTags 6AV2 105-0MA11-0AA0<br />

Incl. 500 archive tags each<br />

SIMATIC WinCC Client for<br />

Runtime Professional<br />

WinCC Client for Runtime 6AV2 107-0DB01-0AA0<br />

Professional<br />

WinCC Client for Runtime 6AV2 107-0DB11-0AA0<br />

Professional ASIA<br />

Power Pack<br />

SIMATIC WinCC Runtime<br />

Professional and<br />

SIMATIC WinCC Runtime<br />

Professional ASIA<br />

Single license, only license key<br />

for PowerTags, from<br />

128 to 512 PowerTags 6AV2 105-2BD01-0BD0<br />

512 to 2048 PowerTags 6AV2 105-2DF01-0BD0<br />

2048 to 4096 PowerTags 6AV2 105-2FH01-0BD0<br />

4096 to 8192 PowerTags 6AV2 105-2HK01-0BD0<br />

8192 to 65536 PowerTags 6AV2 105-2KM01-0BD0<br />

■ More information<br />

Further information can be found in the Internet at:<br />

www.siemens.com/tia-portal<br />

4/18<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Upgrades<br />

SIMATIC WinCC V7.0 to<br />

SIMATIC WinCC Runtime<br />

Professional V11 and<br />

SIMATIC WinCC V7.0 ASIA to<br />

SIMATIC WinCC Runtime<br />

Professional ASIA V11<br />

WinCC V7.0 Runtime<br />

128 PowerTags to WinCC<br />

Runtime Professional<br />

128 PowerTags<br />

WinCC V7.0 Runtime<br />

512 PowerTags to WinCC<br />

Runtime Professional<br />

512 PowerTags<br />

WinCC V7.0 Runtime<br />

2048 PowerTags to WinCC<br />

Runtime Professional<br />

2048 PowerTags<br />

WinCC V7.0 Runtime<br />

8192 PowerTags to WinCC<br />

Runtime Professional<br />

8192 PowerTags<br />

WinCC V7.0 Runtime<br />

65536 PowerTags to WinCC<br />

Runtime Professional<br />

65536 PowerTags<br />

WinCC V7.0 RC/RT128 / RC/RT<br />

Client to WinCC Client for<br />

Runtime Professional V11<br />

1) Runtime licenses for WinCC Runtime Professional options must be<br />

purchased separately for each target system.<br />

Hardware for process control functions<br />

Note:<br />

6AV2 105-4BB01-0AE0<br />

6AV2 105-4DD01-0AE0<br />

6AV2 105-4FF01-0AE0<br />

6AV2 105-4KK01-0AE0<br />

6AV2 105-4MM01-0AE0<br />

6AV2 107-0DB01-0AE0<br />

DCF-77 receiver<br />

for time synchronization<br />

DCF77 (Europe) 2XV9 450-1AR14<br />

GPS (worldwide)<br />

Multi-VGA<br />

N 2XV9 450-1AR13<br />

2 screens A 6ES7 652-0XX03-1XE0<br />

4 screens A 6ES7 652-0XX03-1XE1<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

N: Subject to export regulations: AL: N and ECCN: 7A994A<br />

For further information about process control options, see<br />

<strong>Catalog</strong> <strong>ST</strong> <strong>PC</strong>S 7.


■ Overview<br />

MPI, PROFIBUS<br />

(S7 communication)<br />

PPI<br />

(PPI protocol)<br />

Software interface<br />

(S7 communication)<br />

SINUMERIK 2)<br />

Ethernet TCP/IP<br />

(S7 communication)<br />

MPI<br />

(S7 communication)<br />

Channel for communication via<br />

Ethernet TCP/IP with max. 8 x<br />

SIMATIC S7 controllers<br />

S7-1200,<br />

S7-300, S7-400,<br />

S7-200 with CP 243-1<br />

Channel for communication via<br />

MPI, PROFIBUS with max. 8 x<br />

SIMATIC S7 controllers<br />

S7-1200 with CM 1243-5<br />

(DP master),<br />

S7-300, S7-400,<br />

S7-200 (only passive S7-200)<br />

Channel for communication via<br />

PPI with<br />

1 x SIMATIC S7-200<br />

(network operation, e.g. parallel<br />

PG possible)<br />

Channel for communication via<br />

software interface with WinAC<br />

Channel for communication via<br />

Ethernet TCP/IP<br />

with SINUMERIK 840D sl<br />

Channel for communication via<br />

MPI<br />

with SINUMERIK 840D sl<br />

CP 5611 A2<br />

CP 5621<br />

CP 5512<br />

CP 5711<br />

CP 5613 A2<br />

CP 5623<br />

CP 5611 A2<br />

CP 5621<br />

CP 5512<br />

CP 5711<br />

CP 5613 A2<br />

CP 5623<br />

CP 1612 A2<br />

CP 1613 A2<br />

CP 1623<br />

CP 5611 A2<br />

CP 5621<br />

CP 5512<br />

CP 5711<br />

CP 5613 A2<br />

CP 5623<br />

1) HTTP and O<strong>PC</strong> communication can be used in combination with the<br />

other couplings; regarding SIMATIC Panels that support HTTP or<br />

O<strong>PC</strong> communication, see the overview under "System interfaces<br />

(WinCC V11)".<br />

2) "SINUMERIK Operate WinCC RT Advanced" license required;<br />

for further information, see NC 60 <strong>Catalog</strong>.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) Runtime<br />

WinCC Runtime Communication<br />

SIMATIC WinCC Runtime Advanced<br />

WinCC Advanced is an open visualization system and offers the<br />

option of connecting the most diverse control systems.<br />

Number of connectable controllers<br />

WinCC Advanced permits the parallel coupling of up to<br />

8 controllers.<br />

Connection to third-party controllers<br />

The following "Coupling overview" table lists third-party protocols<br />

and controllers which are directly supported by WinCC<br />

Advanced. Generally it is also possible to connect third-party<br />

controllers via O<strong>PC</strong> (OLE for Process Control).<br />

Current notes and information about O<strong>PC</strong> servers from many<br />

different suppliers can be found at:<br />

www.opcfoundation.org/<br />

WinCC Advanced supports the standards:<br />

O<strong>PC</strong> Data Access 2.05a<br />

O<strong>PC</strong> XML Data Access 1.00 (client via DCOM/XML gateway)<br />

Coupling overview for WinCC Runtime Advanced<br />

Protocol Description <strong>PC</strong> interface<br />

SIMATIC HMI<br />

Ethernet TCP/IP HTTP communication for data<br />

(HTTP communication)<br />

exchange between SIMATIC<br />

HMI (client + server) 1)<br />

Third-party controllers (from WinCC V11.0)<br />

CP 1612 A2<br />

SIMATIC S7<br />

Ethernet TCP/IP<br />

(S7 communication)<br />

CP 1612 A2<br />

CP 1613 A2<br />

CP 1623<br />

3)<br />

Allen Bradley Channel for communication CP 1612 A2<br />

Ethernet IP<br />

with max. 4 x Allen Bradley<br />

controllers via Ethernet TCP/IP<br />

with Allen Bradley Ethernet IP<br />

protocol<br />

The controllers ControlLogix /<br />

CompactLogix, SLC500 /<br />

MicroLogix and PLC5 are<br />

supported<br />

Allen Bradley DF1 Channel for communication<br />

with Allen Bradley controllers<br />

via DF1 protocol<br />

The controllers SLC500 /<br />

MicroLogix and PLC5 are<br />

supported 3)<br />

Protocol Description <strong>PC</strong> interface<br />

COM1/COM2<br />

Mitsubishi MC<br />

TCP/IP<br />

Channel for communication<br />

with max. 4 x Mitsubishi<br />

controllers via Ethernet TCP/IP<br />

CP 1612 A2<br />

with Mitsubishi MC TCP/IP<br />

protocol<br />

The FX3, Q, and iQ/QnUD<br />

controller series are supported<br />

Mitsubishi FX Channel for communication COM1/COM2<br />

with Mitsubishi controllers via<br />

FX protocol<br />

The FX1N, FX2N controllers are<br />

supported<br />

Modbus TCP/IP Channel for communication<br />

with max. 4 x Modicon<br />

CP 1612 A2<br />

controllers via Ethernet TCP/IP<br />

using the Modbus TCP/IP<br />

protocol<br />

The Quantum, Momentum,<br />

Premium, TSX Micro, Compact<br />

and M340 controllers are<br />

supported<br />

COM1/COM2<br />

Modbus RTU Channel for communication<br />

with Modicon controllers via the<br />

Modbus RTU protocol<br />

The Quantum, Momentum, and<br />

Compact controllers are<br />

supported<br />

Omron Link / Multi<br />

Link<br />

Cross-manufacturer<br />

O<strong>PC</strong> client 1) 4) for<br />

DA, XML DA<br />

Channel for communication<br />

with Omron controllers via the<br />

Link/Multi protocol<br />

The CP1x, CJ1x, CJ2H, CS1x,<br />

and CP2MC controllers are<br />

supported<br />

Channel for O<strong>PC</strong> communication,<br />

WinCC can acquire data<br />

from O<strong>PC</strong> server applications<br />

O<strong>PC</strong> server for DA Server applications for O<strong>PC</strong><br />

communication; WinCC<br />

provides process data to O<strong>PC</strong><br />

clients<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

COM1/COM2<br />

CP 1612 A2<br />

CP 1612 A2<br />

3) For detailed information regarding supported controllers,<br />

see "System interfaces (WinCC V11)"<br />

4) Application note:<br />

The parallel use of the O<strong>PC</strong> client channel allows, for example, the<br />

connection to an SNMP O<strong>PC</strong> Server for the visualization of the data<br />

present there. The SNMP O<strong>PC</strong> Server enables monitoring of any<br />

network components (e.g. switch) that support the SNMP protocol.<br />

Further information can be found under SIMATIC NET communications<br />

systems/SNMP O<strong>PC</strong> Server.<br />

4/19<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) Runtime<br />

WinCC Runtime Communication<br />

■ Overview (continued)<br />

SIMATIC WinCC Runtime Professional<br />

WinCC Professional is an open process visualization system and<br />

offers the option of connecting the most diverse control systems.<br />

Released communication software<br />

Only communication software with the listed (or higher) product<br />

versions should be used. Corresponding SIMATIC NET<br />

upgrades are available for the upgrading of older versions.<br />

Number of connectable controllers<br />

With CP 1613, a maximum of 64 S7 controllers can be<br />

connected via Industrial Ethernet; with CP 5611 a maximum of 8<br />

and with CP 5613 a maximum of 44 S7 controllers can be<br />

connected via PROFIBUS. With approx. 10 or more controllers,<br />

the use of Industrial Ethernet is recommended.<br />

Client-server communication<br />

Communication between the clients and the server is implemented<br />

using the TCP/IP protocol. The construction of a<br />

separate <strong>PC</strong>-LAN is recommended. For small projects with<br />

correspondingly small message frame advent, a SIMATIC NET<br />

Industrial Ethernet can be used for both process communication<br />

(WinCC/server ↔ PLC) and for <strong>PC</strong>-<strong>PC</strong> communication (WinCC/<br />

client ↔ WinCC/server).<br />

Connection to third-party controllers<br />

The following "Coupling overview" table lists third-party protocols<br />

and controllers which are directly supported by WinCC Professional.<br />

Generally, it is also possible to connect third-party<br />

controllers via O<strong>PC</strong> (OLE for Process Control).<br />

Current notes and information about O<strong>PC</strong> servers from many<br />

different suppliers can be found at:<br />

www.opcfoundation.org/<br />

WinCC Professional supports the following standards:<br />

O<strong>PC</strong> Data Access 2.05a<br />

O<strong>PC</strong> Data Access 3.00<br />

O<strong>PC</strong> XML Data Access 1.00 (Connectivity Pack/Connectivity<br />

Station)<br />

O<strong>PC</strong> HDA 1.20 (Connectivity Pack/Connectivity Station)<br />

O<strong>PC</strong> A&E 1.10 (Connectivity Pack/Connectivity Station)<br />

4/20<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Coupling overview for WinCC Runtime Professional<br />

Protocol<br />

SIMATIC S7<br />

Description <strong>PC</strong> interface<br />

SIMATIC S7 Protocol Protocol Suite with channel CP 1612 A2<br />

Suite<br />

units for communication CP 1613 A2<br />

with SIMATIC S7 via CP 5611 A2<br />

Ethernet TCP/IP<br />

CP 5621<br />

(S7 communication) to CP 5512<br />

S7-1200, S7-300, S7-400 CP 5711<br />

MPI, PROFIBUS<br />

CP 5613 A2<br />

(S7 communication) to<br />

S7-1200 with CM 1243-5<br />

(DP master), S7-300,<br />

S7-400<br />

Software interface<br />

(S7 communication) to<br />

Win AC<br />

CP 5623<br />

Third-party controllers (from WinCC V11.0)<br />

Allen Bradley Ethernet<br />

IP<br />

Channel for communication<br />

with Allen Bradley<br />

controllers via Ethernet<br />

TCP/IP with Ethernet IP<br />

protocol<br />

The controllers Control-<br />

Logix / CompactLogix,<br />

SLC500 / MicroLogix, and<br />

PLC5 are supported<br />

Mitsubishi MC TCP/IP Channel for communication<br />

with Mitsubishi controllers<br />

via Ethernet TCP/IP with<br />

Mitsubishi MC TCP/IP<br />

protocol<br />

The FX3, Q, and iQ/QnUD<br />

controller series are<br />

supported<br />

Modbus TCP/IP Channel for communication<br />

with Modicon controllers<br />

via Ethernet TCP/IP using<br />

the Modbus TCP/IP<br />

protocol<br />

The Quantum, Momentum,<br />

Premium, TSX Micro,<br />

Compact and M340<br />

controllers are supported<br />

Cross-manufacturer<br />

O<strong>PC</strong> client 1) for<br />

DA, XML DA<br />

O<strong>PC</strong> Server for DA,<br />

XML DA, A&E, HDA<br />

Channel for O<strong>PC</strong> communication,<br />

WinCC can acquire<br />

data from O<strong>PC</strong> server<br />

applications<br />

Server applications for<br />

O<strong>PC</strong> communication;<br />

WinCC provides process<br />

data to O<strong>PC</strong> clients<br />

CP 1612 A2<br />

CP 1612 A2<br />

CP 1612 A2<br />

CP 1612 A2<br />

CP 1612 A2<br />

1) Application note:<br />

The parallel use of the O<strong>PC</strong> client channel allows, for example, the<br />

connection to an SNMP O<strong>PC</strong> Server for visualization of the data<br />

presented there.<br />

The SNMP O<strong>PC</strong> Server enables monitoring of any network components<br />

(e.g. switch) that support the SNMP protocol. Further information<br />

can be found under SIMATIC NET communications systems/<br />

SNMP O<strong>PC</strong> Server.


■ Overview (continued)<br />

Communications examples<br />

WinCC Runtime Advanced single-user system<br />

WinCC RT<br />

Professional<br />

Client<br />

Industrial Ethernet<br />

Industrial Ethernet<br />

PROFIBUS<br />

WinCC<br />

Runtime<br />

Advanced<br />

SIMATIC S7-300<br />

WinCC RT<br />

Professional<br />

Client<br />

PROFIBUS<br />

WinCC Runtime Professional multi-user system with operable server<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) Runtime<br />

SIMATIC S7-1200<br />

WinCC RT<br />

Professional<br />

Client<br />

WinCC RT<br />

Professional<br />

Server<br />

SIMATIC S7-400 SIMATIC S7-400<br />

WinCC Runtime Communication<br />

SIMATIC S7-400<br />

WinCC RT<br />

Professional<br />

Client<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

<br />

<br />

4/21<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) Runtime<br />

WinCC Runtime Communication<br />

■ Overview (continued)<br />

O<strong>PC</strong> coupling<br />

4/22<br />

Industrial Ethernet<br />

PROFIBUS<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

WinCC RT<br />

Advanced<br />

SIMATIC S7-300<br />

O<strong>PC</strong> Server<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

O<strong>PC</strong> Client<br />

WinCC RT<br />

Professional<br />

SIMATIC S7-1200


HMI Software<br />

SIMATIC WinCC (TIA Portal) Runtime<br />

■ Ordering data Order No. Order No.<br />

SIMATIC WinCC V11 communication<br />

Communication via Industrial<br />

Ethernet TCP/IP<br />

CP 1612 A2<br />

<strong>PC</strong>I card (32-bit) for connection of<br />

a programming device or <strong>PC</strong> to<br />

Industrial Ethernet<br />

(10/100/1000 Mbit/s) with RJ45<br />

connection via SOFTNET S7 and<br />

SOFTNET PG.<br />

Software requirement:<br />

WinCC Runtime Advanced:<br />

No further installation is required<br />

(SOFTNET-S7)<br />

WinCC Runtime Professional:<br />

SOFTNET-S7 Lean (maximum of<br />

8 connections) or SOFTNET-S7<br />

(maximum of 64 connections)<br />

must be installed<br />

(SOFTNET-S7 Lean is included in<br />

the scope of delivery of WinCC<br />

Runtime Professional)<br />

SOFTNET-S7 Version 8.0 SP1 /<br />

Edition 2008 SP2 (V7.1)<br />

Software for S7 and<br />

S5-compatible communication,<br />

incl. O<strong>PC</strong> server,<br />

PG/OP communication and<br />

NCM <strong>PC</strong>; up to 64 connections,<br />

single license for 1 installation,<br />

runtime software, software and<br />

electronic manual on CD-ROM,<br />

license key on USB flash drive,<br />

Class A<br />

Version 8.0 SP1<br />

For (32-bit) Windows 7 Ultimate,<br />

Professional;<br />

for CP 1612; CP 1612 A2<br />

German/English<br />

(included in the scope of delivery:<br />

Edition 2008 SP2 (V7.1))<br />

Edition 2008 SP2 (V7.1)<br />

For (32-bit) Windows XP<br />

Professional, Windows 2003<br />

Server, VI<strong>ST</strong>A Ultimate/Business;<br />

for CP 1612; CP 1612 A2<br />

German/English<br />

B 6GK1 161-2AA01<br />

Single license for 1 installation D 6GK1 704-1CW<strong>80</strong>-3AA0<br />

Upgrade package for SIMATIC D<br />

NET from Edition 2006<br />

6GK1 704-1CW00-3AE0<br />

Upgrade package for SIMATIC D<br />

NET V6.0, V6.1, V6.2 and<br />

Edition 2005<br />

6GK1 704-1CW00-3AE1<br />

SOFTNET-S7 Lean Version 8.0<br />

SP1 / Edition 2008 SP2 (V7.1)<br />

(included in the scope of delivery<br />

of WinCC V11)<br />

Software for S7 and<br />

S5-compatible communication,<br />

incl. O<strong>PC</strong> server,<br />

PG/OP communication and<br />

NCM <strong>PC</strong>; up to 8 connections,<br />

single license for 1 installation,<br />

runtime software, software and<br />

electronic manual on CD-ROM,<br />

license key on USB flash drive,<br />

Class A<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

WinCC Runtime Communication<br />

Version 8.0 SP1<br />

For (32-bit) Windows 7 Ultimate,<br />

Professional; for CP 1612;<br />

CP 1612 A2 German/English<br />

(included in scope of supply:<br />

Edition 2008 SP2 (V7.1))<br />

Edition 2008 SP2 (V7.1)<br />

For (32-bit) Windows XP<br />

Professional, Windows 2003<br />

Server, VI<strong>ST</strong>A Ultimate/Business;<br />

for CP 1612; CP 1612 A2<br />

German/English<br />

Single license for 1 installation D 6GK1 704-1LW<strong>80</strong>-3AA0<br />

Upgrade package for<br />

SIMATIC NET from Edition 2006<br />

D 6GK1 704-1LW00-3AE0<br />

Upgrade package for<br />

SIMATIC NET V6.0, V6.1, V6.2<br />

and Edition 2005<br />

D 6GK1 704-1LW00-3AE1<br />

CP 1613-A2<br />

<strong>PC</strong>I card (32 bit) for connecting a<br />

PG/<strong>PC</strong> to Industrial Ethernet<br />

(communications software must<br />

be ordered separately)<br />

S7-1613 Version 8.0 SP1 /<br />

Edition 2008 SP2 (V7.1)<br />

Software for S7 and<br />

S5-compatible communication,<br />

incl. PG/OP communication,<br />

O<strong>PC</strong> server and NCM <strong>PC</strong>; up to<br />

120 connections, single license<br />

for 1 installation, runtime software,<br />

software and electronic manual<br />

on CD-ROM, license key on<br />

USB flash drive, Class A<br />

Version 8.0 SP1<br />

For (32-bit) Windows 7 Ultimate,<br />

Professional; for CP 1613;<br />

CP 1613 A2, CP 1623<br />

German/English<br />

(included in the scope of delivery:<br />

Edition 2008 SP2 (V7.1))<br />

Edition 2008 SP2 (V7.1)<br />

For (32-bit) Windows XP<br />

Professional, Windows 2003<br />

Server, VI<strong>ST</strong>A Ultimate/Business;<br />

for CP 1613; CP 1613 A2,<br />

CP 1623 German/English<br />

6GK1 161-3AA01<br />

Single license for 1 installation D 6GK1 716-1CB<strong>80</strong>-3AA0<br />

Upgrade package for<br />

SIMATIC NET from Edition 2006<br />

D 6GK1 716-1CB00-3AE0<br />

Upgrade package for<br />

SIMATIC NET V6.0, V6.1, V6.2<br />

and Edition 2005<br />

D 6GK1 716-1CB00-3AE1<br />

CP 1623 6GK1 162-3AA00<br />

<strong>PC</strong>I Express X1 card (32-bit)<br />

for connection of PG/<strong>PC</strong> to<br />

Industrial Ethernet<br />

(communications software to be<br />

ordered separately)<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/23<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) Runtime<br />

WinCC Runtime Communication<br />

■ Ordering data Order No. Order No.<br />

Communication via PROFIBUS<br />

<strong>PC</strong> adapter USB 6ES7 972-0CB20-0XA0<br />

Can be used under Windows XP<br />

CP 5611 A2 6GK1 561-1AA01<br />

<strong>PC</strong>I card (32-bit) for connecting<br />

a PG/<strong>PC</strong> to PROFIBUS<br />

(communications software<br />

included in the WinCC basic<br />

package)<br />

CP 5621<br />

<strong>PC</strong>I Express X1 card (32-bit) for<br />

connection of PG/<strong>PC</strong> to<br />

PROFIBUS (communications<br />

software included in WinCC basic<br />

package)<br />

E 6GK1 562-1AA00<br />

CP 5621 MPI<br />

Comprising CP 5621 (32-bit) and<br />

MPI cable, 5 m<br />

E 6GK1 562-1AM00<br />

CP 5512<br />

<strong>PC</strong>MCIA card (CARDBUS 32-bit)<br />

for the connection of a PG/<br />

notebook to PROFIBUS or MPI<br />

(communications software<br />

included in WinCC basic<br />

package)<br />

6GK1 551-2AA00<br />

CP 5711<br />

USB adapter for connecting a<br />

PG/<strong>PC</strong> to PROFIBUS or MPI<br />

(communications software<br />

included in the WinCC basic<br />

package)<br />

A 6GK1 571-1AM00<br />

CP 5613 A2 6GK1 561-3AA01<br />

<strong>PC</strong>I card (32-bit) for connecting a<br />

<strong>PC</strong> to PROFIBUS<br />

(communications software must<br />

be ordered separately).<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

4/24<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

CP 5623<br />

<strong>PC</strong>I Express X1 card (32-bit)<br />

for connection of PG/<strong>PC</strong> to<br />

Industrial Ethernet<br />

(communications software to be<br />

ordered separately)<br />

S7-5613 Version 8.0 SP1 /<br />

Edition 2008 SP2 (V7.1)<br />

Software for S7 Communication<br />

incl. PG/OP protocol, FDL,<br />

O<strong>PC</strong> server; runtime software,<br />

software and electronic manual<br />

on CD-ROM, license key on<br />

USB flash drive, Class A<br />

Version 8.0 SP1<br />

For (32-bit) Windows 7 Ultimate,<br />

Professional; for CP 5613 A2,<br />

CP 5623 German/English<br />

For (32-bit) Windows XP<br />

Professional, Windows 2003<br />

Server, VI<strong>ST</strong>A Ultimate/Business;<br />

for CP 5613 A2, CP 5623<br />

German/English<br />

E 6GK1 562-3AA00<br />

Single license for 1 installation D 6GK1 713-5CB<strong>80</strong>-3AA0<br />

Upgrade package for<br />

SIMATIC NET from Edition 2006<br />

D 6GK1 713-5CB00-3AE0<br />

Upgrade package,<br />

for SIMATIC NET V6.0, V6.1,<br />

V6.2, and Edition 2005<br />

D 6GK1 713-5CB00-3AE1


■ Overview<br />

Options for SIMATIC Panels, SIMATIC WinCC Runtime<br />

Advanced and SIMATIC WinCC Runtime Professional<br />

SIMATIC WinCC Logging<br />

for SIMATIC WinCC Runtime Advanced and<br />

SIMATIC WinCC Runtime Professional<br />

Logging of alarms and process values<br />

Online evaluation of process value logs and alarm logs<br />

Evaluation of process value and alarm logs using standard<br />

MS tools such as Excel<br />

SIMATIC WinCC Recipes<br />

for SIMATIC WinCC Runtime Advanced and<br />

SIMATIC WinCC Runtime Professional<br />

Generation and management of data records for machine or<br />

production data<br />

Display or entry of data records via a configurable screen<br />

object or via process screens distributed within the project<br />

Transmission of data records from or to the controller<br />

Import/export of data records for further processing with other<br />

tools (e.g. MS Excel)<br />

SIMATIC WinCC Audit<br />

for SIMATIC Panels and<br />

SIMATIC WinCC Runtime Advanced<br />

Recording of operator actions in an Audit Trail<br />

Electronic signature for important operator actions relevant to<br />

production<br />

Audit supports users in meeting special quality requirements,<br />

e.g.<br />

- Production plant requiring validation according to<br />

21 CFR Part 11 (Food Drug Administration Law)<br />

- In respect of traceability according to EU 175/2002<br />

(EU directive)<br />

SIMATIC Logon<br />

for SIMATIC Panels and SIMATIC WinCC Runtime Advanced<br />

and SIMATIC WinCC Runtime Professional<br />

Creates user administration on a central computer to which<br />

one or more WinCC stations can be connected over the<br />

Ethernet network.<br />

With each logging-on/off of a user on one of the connected<br />

stations, SIMATIC Logon checks whether a user password has<br />

been created and if the required privileges exist.<br />

SIMATIC Logon supports the user in combination with the<br />

Audit option in meeting requirements in accordance with<br />

FDA 21 CFR Part 11 and EU178.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) options<br />

SIMATIC WinCC (TIA Portal) options<br />

SIMATIC WinCC Sm@rtServer<br />

for SIMATIC Panels and SIMATIC WinCC Runtime Advanced<br />

Flexible solution for remote access to HMI systems<br />

Remote maintenance of machines and plants<br />

via the Internet/Intranet<br />

Reduced downtimes for machines and plants<br />

due to direct remote access<br />

Flexible solution for remote access to machines and plants<br />

SIMATIC WinCC Server and SIMATIC WinCC Client<br />

for SIMATIC WinCC Runtime Professional<br />

For setting up a high-performance client-server system<br />

A number of coordinated operator control and monitoring<br />

systems can be operated in a single group with networked<br />

automation systems<br />

Client/server solution:<br />

- One server can supply up to 32 connected clients with<br />

process and archive data, alarms, screens and reports<br />

- Depending on the size of the plant, up to 12 servers and<br />

32 clients can be employed.<br />

SIMATIC WinCC WebNavigator<br />

for SIMATIC WinCC Runtime Professional<br />

Operator control and monitoring of plants via the Internet or<br />

the in-house intranet or LAN<br />

Web Client permits the operator control and monitoring of a<br />

current WinCC Runtime Professional project via an Internet<br />

browser with ActiveX support.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/25<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) options<br />

WinCC Recipes<br />

■ Overview<br />

Option for SIMATIC WinCC Runtime Advanced and WinCC<br />

Runtime Professional for managing data records in recipes<br />

that contain related machine or production data<br />

The data in a data set can be transferred, for example, from<br />

the operator panel to the PLC to switch production to a<br />

different product version<br />

Licensing:<br />

- SIMATIC Panels / Multi Panels / Comfort Panels:<br />

No license is required.<br />

- WinCC Runtime Advanced:<br />

One license is required per operator station<br />

- WinCC Runtime Professional:<br />

A license is only required on the server (or single-user<br />

system).<br />

4/26<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Generation and management of machine parameters and<br />

production data on the basis of data records, and exchange<br />

with the automation device, e.g. with the machine.<br />

Clear tabular representation of the data elements with the aid<br />

of a configurable screen object, or depiction in technological<br />

relationships across several process screens.<br />

Simple operator guidance through standard functions.<br />

Export/import of data records for further processing with other<br />

tools (e.g. MS Excel)<br />

■ Function<br />

Input of data records (e.g. operating parameters of a<br />

machine, production data for a plastics machine) on the<br />

operator panel as well as their storage and transfer to the<br />

control<br />

Display or entry of data records via a configurable screen<br />

object or via several process screens distributed within the<br />

project<br />

The data record elements are coupled with the process via a<br />

direct tag connection<br />

Transmission of data records from or to the controller<br />

Powerful interfaces enable a synchronized data exchange<br />

with the controller<br />

Storage of data records on local data carriers or on remote<br />

data servers via networks<br />

Logging of data records, e.g. as batch report/shift report<br />

User-friendly and flexible management of data records by<br />

powerful standard functions<br />

The recipes and the associated data records are created using<br />

a separate, user-friendly WinCC Engineering editor and data is<br />

pre-assigned to them. A configurable table object is used for<br />

displaying the data at runtime. Furthermore, the individual data<br />

record elements can also be displayed directly based on<br />

standard input/output fields across several process screens.<br />

In this way, the data in technological views can be presented<br />

clearly to the operator.<br />

Import and export functions support the importing and exporting<br />

of data via external applications (e.g. MS Excel).


■ Technical specifications<br />

WinCC Recipes for Runtime<br />

Advanced<br />

The values specified are<br />

maximum values<br />

Number of recipes 999<br />

Number of elements per recipe 1) 2000<br />

User data length in KB per data<br />

record<br />

256<br />

Number of data records per recipe 5000<br />

1) When using arrays, each array element represents a recipe element<br />

WinCC Recipes for Runtime<br />

Professional<br />

The values specified are<br />

maximum values<br />

Number of recipes Unlimited 1)<br />

Number of elements per recipe 1) 500 2)<br />

User data length in KB per data<br />

record<br />

3000 2)<br />

Number of data records per recipe 5000 1)<br />

1) Limited by system resources.<br />

2) The sum of the number of recipe elements and number of data<br />

records must not exceed a value of 320,000.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) options<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

WinCC Recipes<br />

■ Ordering data Order No.<br />

WinCC Recipes for Runtime<br />

Advanced 1)<br />

6AV2 107-0JA00-0BB0<br />

Single license, license key only<br />

WinCC Recipes + Logging for<br />

Runtime Advanced 1)<br />

6AV2 107-0HA00-0BB0<br />

Single License for each option,<br />

license key only<br />

WinCC Recipes for Runtime<br />

Professional 1)<br />

6AV2 107-0JB00-0BB0<br />

Single License for each option,<br />

license key only<br />

1) One license is required for each operator console. A license is not<br />

required for the engineering system for configuring the runtime option.<br />

4/27<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) options<br />

WinCC Logging<br />

■ Overview<br />

Option for SIMATIC WinCC Runtime Advanced and WinCC<br />

Runtime Professional for logging process values and alarms<br />

Logging of process values and alarms supports the<br />

acquisition and processing of process data from an industrial<br />

plant or machine. Evaluation of the logged process data<br />

provides information about the operating states of the plant or<br />

machine<br />

Licensing:<br />

- SIMATIC Panels / Multi Panels / Comfort Panels:<br />

No license is required.<br />

- WinCC Runtime Advanced:<br />

One license is required per operator station<br />

- WinCC Runtime Professional:<br />

500 Logging Tags are already included in the basic package<br />

The number of Logging Tags can be increased by means of<br />

additional licenses<br />

4/28<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Alarm and process value logs enable predictive diagnostics,<br />

which avoids downtimes<br />

Early detection of danger and fault conditions<br />

Increase of the product quality and the productivity thanks to<br />

regular analysis of the alarm and process value logs<br />

■ Application<br />

Transfer of the logs for evaluation and long-term archiving<br />

Detection of recurring error states<br />

Optimization of maintenance cycles<br />

Ensuring the quality standard<br />

Quality assurance and checking the utilization of production<br />

sequences<br />

Documentation of process sequences<br />

■ Function<br />

Time-controlled as well as manual or process-controlled<br />

swapping out of process data and alarms for long-term<br />

archiving<br />

During runtime, swapped out data are read in and selectively<br />

analyzed with WinCC Runtime Advanced or WinCC Runtime<br />

Professional<br />

- Presentation and evaluation of archived process data based<br />

on a configurable trend display. Reading of the values is<br />

facilitated by a read line.<br />

- Presentation and evaluation of archived alarms based on a<br />

configurable alarm view.<br />

- User-friendly navigation in the logs<br />

External evaluation of the logs using MS standard tools<br />

Various log types are supported: sequence and circular logs<br />

Logging of process values and alarms on external,<br />

Windows-supported storage media<br />

- SIMATIC Panels and WinCC Runtime Advanced:<br />

CSV files<br />

RDB files<br />

Microsoft SQL Server via ODBC<br />

- WinCC Runtime Professional:<br />

Microsoft SQL Server 2005<br />

Powerful standard functions permit user-friendly and flexible<br />

utilization of the logs


■ Technical specifications<br />

WinCC Logging for Runtime<br />

Advanced<br />

The values specified are<br />

maximum values<br />

Number of logs 100<br />

Archivable data Process values, alarms<br />

Cyclical trigger for archiving 1 s<br />

process values (variables)<br />

Max. number of entries per log 500,000<br />

(incl. sequence log)<br />

1)<br />

Log types Circular logs,<br />

sequence logs (max. 400 per log)<br />

Data storage format CSV (Comma Separated<br />

Variable),<br />

RDB (Runtime Data Base),<br />

Microsoft SQL database<br />

(database not included in scope<br />

of delivery)<br />

1) Dependent on memory medium used<br />

Number of logs per single-user<br />

station/server<br />

WinCC Logging for Runtime<br />

Professional<br />

The values specified are<br />

maximum values<br />

100<br />

Archivable data Process values, alarms<br />

Measured values per second, max. Server/single-user station:<br />

5 000 per sec.<br />

Log tags per single-user station/<br />

server<br />

<strong>80</strong>,000 2)<br />

Log types Circular log with and without<br />

long-term logging<br />

Data storage format Microsoft SQL 2005 database<br />

2) Dependent on the Logging Power Pack used for the log tags. 500 log<br />

tags are contained in the basis version.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) options<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

WinCC Logging<br />

■ Ordering data Order No.<br />

WinCC Logging<br />

for Runtime Advanced 1)<br />

6AV2 107-0GA00-0BB0<br />

Single license, license key only<br />

WinCC Recipes + Logging<br />

for Runtime Advanced 1)<br />

6AV2 107-0HA00-0BB0<br />

Single License for each option,<br />

license key only<br />

WinCC Logging for Runtime 6AV2 107-0GB00-0BB0<br />

Professional 1500 LoggingTags<br />

Single license, license key only<br />

WinCC Logging for Runtime 6AV2 107-0GD00-0BB0<br />

Professional 5000 LoggingTags<br />

Single License for each option,<br />

license key only<br />

WinCC Logging for Runtime 6AV2 107-2GD00-0BD0<br />

Professional Power Pack<br />

1500 -> 5000 LoggingTags<br />

Single license, license key only<br />

WinCC Logging Upgrade for<br />

SIMATIC WinCC Archives V7.0<br />

(10 licenses)<br />

Single License for each option,<br />

license key only<br />

6AV2 107-4GX00-0BF0<br />

1) One license is required for each operator console. A license is not<br />

required for the engineering system for configuring the runtime option.<br />

4/29<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) options<br />

WinCC Audit<br />

■ Overview<br />

Option for SIMATIC WinCC Runtime Advanced as well as<br />

SIMATIC Panels for recording operations in an audit trail, and<br />

electronic signature.<br />

The audit trail is furnished with a security mechanism that<br />

displays subsequent manipulations.<br />

A user-friendly configuration function, which is included as<br />

standard in WinCC, is used to define the following:<br />

- which user actions should be recorded in the audit trail<br />

during runtime<br />

- which important operator actions during execution time<br />

require electronic signature/comments<br />

Available for the following SIMATIC HMI systems: TP/OP 277,<br />

MP 277, MP 377, Comfort Panels, WinCC Runtime Advanced<br />

Licensing:<br />

- A license is required for every operator control unit<br />

(panel or <strong>PC</strong>).<br />

4/30<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Audit supports the user in meeting special quality<br />

requirements, e.g.<br />

- Production plant requiring validation according to 21 CFR<br />

Part 11 FDA 1)<br />

- In respect of traceability according to EU 175/2002 2)<br />

The entries in the audit trail are positively assigned to the<br />

users; the accountability is thus clearly identifiable.<br />

The audit trail, stored as a CSV file 3) , can be checked via a<br />

security mechanism to find out if subsequent changes have<br />

been made.<br />

For particularly important user actions, e.g., starting<br />

production or loading new recipes, electronic signatures and<br />

comments can be configured and then called up and logged<br />

during runtime.<br />

1) The FDA (Food and Drug Administration) is the American public<br />

health body<br />

2) 21 CFR Part 11- law on plant validation<br />

3) CSV Comma Separated Values<br />

■ Technical specifications<br />

Storage location for Audit Trail when<br />

WinCC Audit<br />

Plug-in Flash memory card or<br />

used on the Panel<br />

via Ethernet in the higher-level <strong>PC</strong><br />

Storage location for Audit Trail when Local hard disk or<br />

using WinCC Runtime Advanced<br />

Execution platform<br />

via Ethernet in the higher-level <strong>PC</strong><br />

SIMATIC Panels Mobile Panel 277, TP/OP 277<br />

SIMATIC Multi Panels MP 277, MP 377<br />

SIMATIC Comfort Panels KTP 400 Comfort, KP 400<br />

Comfort,<br />

TP 700 Comfort, KP 700 Comfort,<br />

TP 900 Comfort, KP 900 Comfort,<br />

TP 1200 Comfort, KP 1200<br />

Comfort<br />

<strong>PC</strong> systems SIMATIC WinCC Runtime<br />

Advanced<br />

■ Ordering data Order No.<br />

WinCC Audit for SIMATIC<br />

Panels<br />

Single License, license key only<br />

WinCC Audit for Runtime<br />

Advanced<br />

Single License, license key only<br />

6AV2 107-0RP00-0BB0<br />

6AV2 107-0RA00-0BB0


■ Overview<br />

Option for connecting SIMATIC Panels and <strong>PC</strong>s with<br />

SIMATIC WinCC Runtime Advanced as well as WinCC<br />

Runtime Professional to a central user administration.<br />

Creates user administration on a central computer to which<br />

one or more panels or WinCC stations can be connected over<br />

Ethernet.<br />

With each logging-on/off of a user on one of the connected<br />

stations, SIMATIC Logon checks whether a user password has<br />

been created and if the required privileges exist.<br />

SIMATIC Logon for Panels and WinCC Runtime Advanced<br />

All users of the SIMATIC Panels or WinCC Runtime Advanced<br />

stations can be managed plant-wide from a central location<br />

Supports the user in combination with the Audit option in<br />

meeting requirements in accordance with FDA 21 CFR Part 11<br />

and EU178.<br />

Licensing:<br />

SIMATIC Logon (basic license) and<br />

SIMATIC Logon Remote Access (3-pack license) for the<br />

connection of 3 panels or WinCC Runtime Advanced stations<br />

to a central user administration. Additional stations can be<br />

connected by using further SIMATIC Logon Remote Access<br />

licenses (3-pack/10-pack).<br />

SIMATIC Logon for WinCC Runtime Professional<br />

All users of WinCC Runtime Professional can be managed<br />

plant-wide from a central location.<br />

The central user management with SL utilizes Windows<br />

mechanisms and must be installed on all participating<br />

WinCC Runtime Professional stations.<br />

Licensing:<br />

SIMATIC Logon (basic license) is included in the basic<br />

package of WinCC Runtime Professional<br />

■ Benefits<br />

Centralized configuration of all access authorizations of a<br />

distributed system avoids unnecessary travel times.<br />

Time-consuming multiple configurations for each individual<br />

local station become unnecessary. Accordingly, users can be<br />

easily configured from a central location.<br />

All access data apply throughout the plant on every<br />

connected station. Additional access data on local<br />

subsystems is no longer necessary.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Design<br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) options<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC Logon<br />

SIMATIC Logon for Panels and WinCC Runtime Advanced<br />

SIMATIC Logon and SIMATIC Logon Remote Access are<br />

installed on a central station.<br />

The following Runtime stations are connected to the central<br />

station via the Ethernet network:<br />

<strong>PC</strong>s with WinCC Runtime Advanced<br />

SIMATIC Panels from the 177 series or higher<br />

(with Ethernet interface)<br />

SIMATIC Mobile Panels from the 177 series or higher<br />

(with Ethernet interface)<br />

SIMATIC Multi Panels<br />

SIMATIC Comfort Panels<br />

SIMATIC Logon for WinCC Runtime Professional<br />

The SIMATIC Logon can be used for the central user<br />

management of several WinCC Runtime Professional stations.<br />

Operation in a Windows Work group or even in a domain is<br />

possible.<br />

■ Function<br />

Users receive a unique user ID, user name and password.<br />

This information is encrypted and stored at a central point (for<br />

SIMATIC Logon in the Windows user management).<br />

Functions such as changing the password, automatic log-off<br />

after a predefined time and lockout after several incorrect entries<br />

of a password ensure a maximum security of operation.<br />

In addition, SIMATIC Logon allows setting up new users online,<br />

plant-wide and across applications, or blocking of existing<br />

users. SIMATIC Logon also supports electronic signature.<br />

■ Ordering data Order No.<br />

SIMATIC Logon V1.4 incl. SP2 6ES7 658-7BX41-2YA0<br />

Basic license 1)<br />

For panels or WinCC Runtime<br />

Advanced stations, the corresponding<br />

number of additional<br />

SIMATIC Logon Remote Access<br />

licenses is required.<br />

No SIMATIC Logon Remote<br />

Access licenses are required for<br />

WinCC Runtime Professional<br />

6ES7 658-7BA00-2YB0<br />

SIMATIC Logon Remote Access<br />

(3 clients)<br />

Remote Access for 3 clients;<br />

Single License for 3 SIMATIC<br />

Logon Remote Access clients;<br />

the number of licensed clients is<br />

determined from the sum of the<br />

installed SIMATIC Logon Remote<br />

Access licenses.<br />

SIMATIC Logon Remote Access<br />

(10 clients)<br />

Remote Access for 10 clients;<br />

Single License for 10 SIMATIC<br />

Logon Remote Access clients;<br />

the number of licensed clients is<br />

determined from the sum of the<br />

installed SIMATIC Logon Remote<br />

Access licenses.<br />

6ES7 658-7BB00-2YB0<br />

1) SIMATIC Logon V1.4 included in scope of supply of WinCC<br />

Professional.<br />

4/31<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) options<br />

WinCC Sm@rtServer<br />

■ Overview<br />

Option for SIMATIC WinCC Runtime Advanced<br />

plus SIMATIC Panels for communication between various<br />

SIMATIC HMI systems.<br />

Available for the following SIMATIC HMI systems:<br />

- Mobile Panel 177 PN, Mobile Panel 277<br />

- TP 177B PN/DP, OP 177B PN/DP<br />

- TP 277, OP 277<br />

- MP 177, MP 277, MP 377<br />

- Comfort Panels<br />

- WinCC Runtime Advanced<br />

■ Benefits<br />

4/32<br />

Master Station<br />

Industrial Ethernet<br />

Flexible solution for remote access to HMI systems<br />

Quick elimination of malfunctions or downtimes – thus<br />

increasing the productivity – through global access to<br />

machines/plants by the service and maintenance personnel<br />

Avoidance of on-site service calls<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Sm@rtServer Sm@rtClient<br />

Operator Station 1 Operator Station 2 Operator Station n<br />

...<br />

A SIMATIC HMI system can be used to control or monitor<br />

another system remotely; entry level for client/server<br />

configurations for distributed operator stations or for solutions<br />

with head end or control room<br />

Local operation, visualization and data processing are as<br />

possible as plant-wide access to information. Integrated<br />

information flows ensure an overview of the status of all<br />

processes.<br />

Licensing:<br />

The "SIMATIC WinCC Sm@rtServer for Panel" or "SIMATIC<br />

WinCC Sm@rtServer for WinCC Runtime Advanced" license<br />

must be installed on the server operator panel. A license is not<br />

required for the engineering system for configuring the<br />

runtime option.<br />

G_<strong>ST</strong><strong>80</strong>_XX_00071


■ Application<br />

Operator control and monitoring of machines covering large<br />

areas with several operator stations by one operator.<br />

Operator control and monitoring of machine-level<br />

HMI systems from one central station (e.g. head-end station of<br />

a production line or from a control room)<br />

Remote maintenance and servicing of machines/plants over<br />

the Internet/Intranet<br />

Master Station<br />

Industrial Ethernet<br />

Application of the Sm@rtClient concept: Coordinated operation of several operator stations<br />

Industrial Ethernet<br />

Sm@rtServer Sm@rtClient<br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) options<br />

Operator Station 1 Operator Station 2 Operator Station n<br />

Server 1 Server 2 Server 3 Server 4<br />

PROFIBUS<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Use of the Sm@rtClient display: Operator control and monitoring of machine-level HMI systems from one central station<br />

...<br />

WinCC Sm@rtServer<br />

Master Control Station Sm@rtClient display<br />

Sm@rtServer Sm@rtServer Sm@rtServer Sm@rtServer<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00071<br />

G_<strong>ST</strong><strong>80</strong>_XX_00072<br />

4/33<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) options<br />

WinCC Sm@rtServer<br />

■ Application (continued)<br />

4/34<br />

<br />

<br />

<br />

Remote operator control and monitoring of SIMATIC HMI systems using<br />

Industrial Ethernet and/or via the Intranet/Internet<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

<br />

<br />

<br />

<br />

<br />

<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00073<br />

Engineering Station<br />

<strong>PC</strong>/PG<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Remote operator control and monitoring of SIMATIC HMI systems using<br />

Industrial Ethernet and/or via the Intranet/Internet


Mobile Panel 277,<br />

TP/OP 277,<br />

MP 277 as Sm@rtServer<br />

Comfort Panel<br />

as Sm@rtServer<br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) options<br />

WinCC Sm@rtServer<br />

■ Function<br />

■ Ordering data Order No.<br />

Coordinated operation of several operator stations:<br />

The HMI application and communication with the controller<br />

WinCC Sm@rtServer for<br />

SIMATIC Panels<br />

takes place via the master station. "Sm@rtClients" can be<br />

activated from here in the case of machines/plants with larger<br />

dimensions which require a larger number of operator panels.<br />

The Sm@rtClients are then provided with access to the master<br />

station and thus to the process. Access procedures guarantee<br />

that only one operator system can actively access the process<br />

at any given time.<br />

1) The license must be installed on the Sm@rtServer operator panel.<br />

Embedded in process screens, a configurable screen object<br />

(Sm@rtClient display) represents the screen of the relevant<br />

HMI system (Sm@rtServer)<br />

Powerful standard functions permit user-friendly and flexible<br />

operation of the display<br />

Remote control of an operating station:<br />

The HMI application and communication with the controller<br />

takes place via the HMI system. Using the Sm@rtServer, the<br />

HMI systems in the machines/systems can be serviced<br />

remotely. An access process ensures that only one operator<br />

(either locally at the machine or remotely via Internet Explorer)<br />

can actively access the process at one time.<br />

Microsoft Internet Explorer V6.0 SP1 or higher is sufficient for<br />

accessing an HMI system.<br />

■ Technical specifications<br />

WinCC Sm@rtServer<br />

The values specified are<br />

maximum values<br />

Execution platform<br />

A license is not required for the engineering system for configuring<br />

the runtime option.<br />

SIMATIC Panels Mobile Panel 177 PN,<br />

Mobile Panel 277,<br />

TP/OP 177B PN/DP,<br />

TP/OP 277<br />

SIMATIC Multi Panels MP 177,<br />

MP 277,<br />

MP 377<br />

SIMATIC Comfort Panels KTP 400 Comfort, KP 400 Comfort,<br />

TP 700 Comfort, KP 700 Comfort,<br />

TP 900 Comfort, KP 900 Comfort,<br />

TP 1200 Comfort,<br />

KP 1200 Comfort<br />

<strong>PC</strong> systems<br />

Number of Sm@rtClients that<br />

can simultaneously connect<br />

to a Sm@rtServer<br />

SIMATIC WinCC Runtime<br />

Advanced<br />

Mobile Panel 177 PN,<br />

TP/OP 177B PN/DP,<br />

MP 177 as Sm@rtServer<br />

2 clients<br />

3 clients for 6" devices<br />

2 clients for 8" and 10" devices<br />

1)<br />

6AV2 107-0CP00-0BB0<br />

Single license, license key only<br />

WinCC Sm@rtServer for<br />

Runtime Advanced 1)<br />

Single license, license key only<br />

6AV2 107-0CA00-0BB0<br />

2 clients for 4" devices,<br />

3 clients for 7", 9" and 12" devices<br />

MP 377 as Sm@rtServer 3 clients for 12" devices<br />

2 clients for 15" devices<br />

1 client for 19" devices<br />

WinCC Runtime Advanced as 5 clients<br />

Sm@rtServer<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/35<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) options<br />

WinCC Server / WinCC Client<br />

■ Overview<br />

4/36<br />

SIMATIC S7-400<br />

Option for SIMATIC WinCC Runtime Professional, which<br />

permits the configuration of a powerful client/server system<br />

One of the following operating systems must be available to<br />

install the option on the server: Windows Server 2003,<br />

Windows Server 2003 R2 or Windows Server 2008.<br />

Max. 3 clients can be connected when using<br />

Windows XP Professional.<br />

A number of coordinated operator control and monitoring<br />

systems can be operated in a single group with networked<br />

automation systems<br />

Client/server solution: One server can supply up to<br />

32 connected clients with process and archive data, alarms,<br />

screens and reports<br />

- Requirement: Network connection (TCP/IP) between the<br />

server <strong>PC</strong> and the connected clients<br />

Licensing:<br />

- A WinCC Runtime Professional license on the server<br />

with the appropriate number of PowerTags and the<br />

"WinCC Server for RT Professional" license.<br />

- The "WinCC Client for RT Professional" license on the clients.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

WinCC<br />

Client<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

WinCC<br />

Client<br />

SIMATIC S7-300<br />

TCP/IP<br />

PROCESS BUS<br />

WinCC<br />

Client<br />

SIMATIC S7-1200


■ Benefits<br />

Integrated scalability from the single-user system to the<br />

client/server solution<br />

Considerably expanded quantity structure, relieves the load<br />

on the individual servers, and thus better performance<br />

through the distribution of the overall application or of the<br />

tasks among several servers<br />

■ Application<br />

In a complex plant, WinCC Runtime Professional can be<br />

configured as a distributed system depending on the<br />

requirements:<br />

Functional distribution (e.g. alarm server, log server, etc.),<br />

or<br />

Distribution corresponding to the physical plant structure<br />

(e.g. body-in-white, paint shop, etc.).<br />

■ Function<br />

All process data of a WinCC project is stored in different Runtime<br />

databases, e.g. alarms, trend values, etc. These Runtime<br />

databases are located on a central computer, the WinCC Server,<br />

instead on each operator panel. The operator stations, i.e. the<br />

WinCC Clients, then access the WinCC Server.<br />

WinCC Clients and WinCC Server are independent systems.<br />

You can also connect WinCC Clients subsequently. Alternatively,<br />

you can activate and deactivate a project from a WinCC Client.<br />

For the clients, only the "WinCC Client for RT Professional"<br />

license is required.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) options<br />

WinCC Server / WinCC Client<br />

■ Ordering data Order No.<br />

WinCC Server for Runtime 6AV2 107-0EB00-0BB0<br />

Professional<br />

Single license, license key only<br />

WinCC Client for Runtime 6AV2 107-0DB01-0AA0<br />

Professional V11<br />

Single license, license key only<br />

WinCC Client for Runtime 6AV2 107-0DB11-0AA0<br />

Professional ASIA<br />

Single license, license key only<br />

A license is not required for the engineering system for configuring<br />

the runtime option.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/37<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) options<br />

WinCC WebNavigator<br />

■ Overview<br />

<br />

<br />

<br />

Option for SIMATIC WinCC Runtime Professional for<br />

operating and monitoring plants over the Internet, company<br />

Intranet or LAN.<br />

Configuration from:<br />

- A web server with SIMATIC WinCC Runtime Professional<br />

as single-user or server version and a web client that permits<br />

operator control and monitoring of a current WinCC Runtime<br />

Professional project using the Internet Explorer.<br />

4/38<br />

<br />

<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

<br />

<br />

<br />

<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Licensing:<br />

- A license is required in order to use the web server<br />

- Server-based licenses are available for access to the web<br />

server by 3, 10, 25 or 50 clients<br />

- Client-based licenses are available for guaranteed access to<br />

the web server (Diagnostics Client)


■ Benefits<br />

Operator control and monitoring across long distances and on<br />

different platforms (<strong>PC</strong>, local panel, mobile PDA)<br />

Large configurations with up to 50 operator stations<br />

Fast update rates due to event-driven communication<br />

Optimally tailored clients for operating and monitoring,<br />

analysis, service and diagnostics<br />

Acceptance of configuration data for the web, generally<br />

without changes<br />

Minimum maintenance costs due to central software<br />

administration<br />

High security standards and availability<br />

- Support for commonly used security mechanisms (routers,<br />

firewalls, proxy servers)<br />

- WinCC access authorizations and user administration<br />

Support of Microsoft Internet Explorer, including "tabbed<br />

browsing". A new license is not required for separate tabs.<br />

With the WinCC Web Viewer (WinCC Viewer RT), the process<br />

screens can be displayed on the web client independently of<br />

the Internet Explorer. Settings for the client are made on the<br />

client itself. The WinCC Web Viewer can also be used in<br />

conjunction with the MS Terminal Service.<br />

The SIMATIC WinCC WebNavigator can also be operated in<br />

"view only" mode and is thus used as tool for monitoring and<br />

navigating using Internet Explorer or WinCC Web Viewer<br />

(WinCC Viewer RT).<br />

Web server logins and logouts are recorded in the alarm and<br />

audit log.<br />

There is a gadget available for the Windows 7 operating<br />

system in which selected WinCC process screens can be<br />

displayed. No additional WebNavigator license is required for<br />

the gadget. The WebNavigator server can be selected directly<br />

via the gadget.<br />

Security is increased by adjustable automatic logout. If an<br />

automatic logout is to take place, an absolute or inactive time<br />

period can be set.<br />

Highlights:<br />

Access to up to 12 subordinate WinCC Runtime Professional<br />

stations (servers) possible<br />

Web clients offer common views of data on various<br />

WinCC Runtime Professional servers<br />

User-friendly services and tools for distributing customized<br />

objects (controls, files) to web clients can be supplied for use<br />

as an integration platform. These components can then also<br />

be integrated into cross-web/server navigation.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Application<br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) options<br />

WinCC WebNavigator<br />

In addition to the typical use of the WebNavigator in<br />

WANs (Wide Area Networks), the WebNavigator can also<br />

be used to implement especially low-cost applications.<br />

This especially includes applications that have a pronounced<br />

distributed structure (water/wastewater, oil and gas), or in which<br />

access to process information is only sporadic (building<br />

management).<br />

The WebNavigator also permits vertical integration,<br />

i.e. a networked IT landscape with integrated data flow between<br />

the planning and operating level of a company.<br />

Only a standard browser is required for direct access to current<br />

process information.<br />

In addition to Standard WebNavigator licensing, there is the<br />

"Diagnostics Client" with identical functionality but different<br />

licensing. It is especially suitable for the following applications:<br />

Remote diagnostics/operation of several unmanned<br />

WinCC Runtime Professional stations<br />

Central control rooms that monitor several web servers via one<br />

user interface<br />

Power Users that require guaranteed access to the server<br />

regardless of the number of users already logged on to the<br />

server.<br />

■ Design<br />

Licenses for the WebNavigator<br />

The WebNavigator Client software can be installed as many<br />

times as required without the need for a license.<br />

Server-based licensing<br />

- A license is required for using the WebNavigator Server.<br />

- Licenses are available for simultaneous access to the web<br />

server by 3, 10, 25 or 50 clients.<br />

Diagnose Client licensing<br />

- For cost-optimized access by one or a small number of<br />

WebNavigator clients to numerous web servers<br />

(e.g. for diagnostic purposes). This client license provides<br />

guaranteed access to the web servers at any time.<br />

In respect of function there is no difference compared with<br />

regular WebNavigator clients and the two can be mixed.<br />

WebNavigator clients are able to:<br />

access a number of different web servers or<br />

access data on a number of higher-level WinCC Runtime<br />

Professional stations simultaneously via a remote web server<br />

On the server side, only one WebNavigator Diagnostics Server<br />

license or, alternatively, one Standard WebNavigator license is<br />

required.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/39<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC (TIA Portal) options<br />

WinCC WebNavigator<br />

■ Design (continued)<br />

■ Function<br />

Thin Client solutions<br />

WinCC Professional makes setting up and configuring a<br />

The WebNavigator can also run under Windows Server 2003<br />

or Windows Server 2008 terminal services.<br />

A Windows Server 2003 or Windows Server 2008 (or higher)<br />

operating system is required. This makes it possible to connect<br />

SIMATIC Thin Clients as visualization stations to WinCC Runtime<br />

Professional, for example.<br />

WebNavigator server very easy. WinCC process screens to be<br />

visualized via the Internet are created as usual in WinCC Professional<br />

and the web access is activated via a process screen<br />

option. To display WinCC process screens on the web client, the<br />

Microsoft Internet Explorer or browser is used independent of<br />

the supplied WinCC Web Viewer (WinCC Viewer RT).<br />

For this purpose, the Windows terminal services must be<br />

installed on the <strong>PC</strong> on which the Web Client is installed.<br />

A Windows Server 2003 or Windows Server 2008 (or higher)<br />

operating system is required. Up to 25 Thin Clients can be<br />

connected to one terminal server.<br />

Applications:<br />

Mobile devices<br />

The operator on the web client is integrated in the central WinCC<br />

user administration and can operate and monitor the system<br />

according to the configured access rights. The WebNavigator<br />

supports all standard security mechanisms that can be used for<br />

applications on the Internet, e.g. routers, firewalls and proxy<br />

servers.<br />

■ Ordering data Order No.<br />

Handhelds<br />

Rugged on-site visualizations<br />

WinCC WebNavigator for<br />

Runtime Professional<br />

Hybrid configuration<br />

3 clients<br />

10 clients<br />

6AV2 107-0KD00-0BB0<br />

6AV2 107-0KF00-0BB0<br />

WebNavigator and DataMonitor clients can be mixed in a single 25 clients 6AV2 107-0KH00-0BB0<br />

system.<br />

50 clients 6AV2 107-0KK00-0BB0<br />

System requirements: WinCC WebNavigator – Server<br />

Windows 7 (32-bit) Business, Enterprise and Ultimate<br />

(max. 3 clients)<br />

Windows XP Professional Service Pack 2 (max. 3 clients)<br />

100 clients<br />

150 clients<br />

WinCC WebNavigator for<br />

Runtime Professional<br />

Power Packs<br />

6AV2 107-0KM00-0BB0<br />

6AV2 107-0KP00-0BB0<br />

Windows Server 2003 SP2 and Windows Server R2 SP2<br />

From 3 to 10 clients 6AV2 107-2KF00-0BD0<br />

Windows Server 2008<br />

Internet Explorer 7 as well as Internet Explorer 8.<br />

From 10 to 25 clients<br />

From 25 to 50 clients<br />

From 50 to 100 clients<br />

6AV2 107-2KH00-0BD0<br />

6AV2 107-2KK00-0BD0<br />

6AV2 107-2KM00-0BD0<br />

Microsoft SQL Server 2005 SP2 (scope of supply of WinCC) From 100 to 150 clients 6AV2 107-2KP00-0BD0<br />

WinCC Runtime Professional V11<br />

WinCC WebNavigator<br />

System requirements: WinCC WebNavigator – Client<br />

Internet Explorer 7 as well as Internet Explorer 8.<br />

Diagnostics Server/Client<br />

WinCC WebDiagnostics<br />

Server for Runtime Professional<br />

6AV2 107-0KR00-0BB0<br />

WinCC WebDiagnostics<br />

Client for Runtime Professional<br />

6AV2 107-0KT00-0BB0<br />

4/40<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

A license is not required for the engineering system for<br />

configuring the runtime option.


■ Overview<br />

Uniform family of engineering tools for configuration of<br />

SIMATIC HMI operator panels, the operator control part of<br />

SIMATIC C7 units, SIMOTION/SINUMERIK Panel <strong>PC</strong>s as well<br />

as the <strong>PC</strong>-based visualization software WinCC flexible<br />

Runtime.<br />

Runs under Windows XP Professional / Windows 7<br />

Professional, Ultimate, Enterprise<br />

Current version:<br />

- SIMATIC WinCC flexible 2008 Service Pack 2 Advanced<br />

- SIMATIC WinCC flexible 2008 Service Pack 2 Standard<br />

- SIMATIC WinCC flexible 2008 Service Pack 2 Compact<br />

- SIMATIC WinCC flexible 2008 Service Pack 2 Micro<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

HMI Software<br />

SIMATIC WinCC flexible HMI system<br />

SIMATIC WinCC flexible ES<br />

The integrated configuration software reduces training,<br />

maintenance and service overhead and protects the<br />

customer's investments<br />

Minimized engineering overhead and reduction of lifecycle<br />

costs thanks to Totally Integrated Automation (TIA)<br />

Minimized configuration overhead due to reuse of scalable<br />

and dynamizable objects<br />

Intelligent tools for efficient and simple configuration:<br />

- Wizard for defining the basic structure of the HMI project<br />

- Table-based editors simplify the generation and processing<br />

of similar types of object, e.g. for tags, texts, or alarms<br />

- Complex configuration tasks such as the definition of paths<br />

of motion or the creation of the fundamental operator<br />

prompting are simplified by means of graphical<br />

configuration.<br />

Comprehensive support of multi-language configurations for<br />

worldwide use<br />

- Selectable views for entering configuration data in several<br />

languages<br />

- System and user-specific text lexicons<br />

- Export/import of language-dependent texts<br />

Investment protection due to<br />

- Import of the configuration from the configuration tools of the<br />

ProTool family<br />

- Import of static screen contents and tags from WinCC V6.2<br />

■ Application<br />

SIMATIC WinCC flexible Micro/Compact/Standard/Advanced<br />

are innovative engineering tools for configuration SIMATIC HMI<br />

operator panels, the operating component of SIMATIC C7<br />

devices, the SIMOTION/SINUMERIK Panel <strong>PC</strong>s, and the <strong>PC</strong>based<br />

visualization system WinCC flexible Runtime.<br />

Depending on the selected product, various target systems can<br />

be configured:<br />

WinCC flexible Micro<br />

Micro Panels: OP 73micro, TP 170micro, TP 177micro<br />

WinCC flexible Compact<br />

In addition to the target systems that are configured using<br />

WinCC flexible Micro:<br />

Mobile Panels: Mobile Panel 170, Mobile Panel 177<br />

Basic Panels: KTP400 Basic, KTP600 Basic, KTP1000 Basic,<br />

TP1500 Basic<br />

70 series Panels: OP 73, OP 77A, OP 77B<br />

170 series Panels: TP 170A, TP 177A, TP 170B, TP 177B,<br />

OP 170B, OP 177B<br />

170 series Multi Panels: MP 177<br />

C7 devices: C7-635 (Touch/Key)<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/41<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC flexible HMI system<br />

SIMATIC WinCC flexible ES<br />

■ Application (continued)<br />

WinCC flexible Standard<br />

In addition to the target systems that are configured using<br />

WinCC flexible Compact:<br />

Mobile Panels: Mobile Panel 277<br />

270 series Panels: TP 270, TP 277, OP 270, OP 277<br />

270 series Multi Panels: MP 270B, MP 277<br />

370 series Multi Panels: MP 370, MP 377<br />

C7 devices: C7-636 (Touch/Key)<br />

WinCC flexible Advanced<br />

In addition to the target systems that are configured using<br />

WinCC flexible Standard:<br />

Standard <strong>PC</strong><br />

SIMATIC Panel <strong>PC</strong>: Panel <strong>PC</strong> IL 70, Panel <strong>PC</strong> IL 77,<br />

Panel <strong>PC</strong> 477/477B, Panel <strong>PC</strong> 577/577B, Panel <strong>PC</strong> 670,<br />

Panel <strong>PC</strong> 677/677B, Panel <strong>PC</strong> 870, Panel <strong>PC</strong> 877<br />

SIMOTION Panel <strong>PC</strong>: P012K, P012T, P015K, P015T, <strong>PC</strong>R,<br />

<strong>PC</strong>R-Touch<br />

SINUMERIK Panel <strong>PC</strong>: HT8, OP08T, OP010, OP012, TP012,<br />

OP015, TP015, OP015A<br />

For configuring panels released after the start of delivery of<br />

WinCC flexible 2008, an HSP (Hardware Support Package) is<br />

required that can be downloaded free of charge via the following<br />

link:<br />

www.siemens.com/wincc-flexible-hsp<br />

■ Design<br />

The engineering tools of the SIMATIC WinCC flexible range are<br />

based on one another. The available editors largely depend on<br />

the respectively configured target systems and their functions.<br />

A more comprehensive engineering tool such as WinCC flexible<br />

Standard also offers the facilities of the smaller engineering<br />

tools, e.g. WinCC flexible Compact or Micro.<br />

Upgrading of a smaller engineering tool to a larger one is<br />

possible using a Power Pack.<br />

An exception is WinCC flexible Micro.<br />

The scope of functions of the WinCC flexible engineering tools<br />

already includes project support for the Runtime options<br />

available for SIMATIC Panels or WinCC flexible Runtime,<br />

independent of the RT licenses purchased. Separate licensing<br />

is required for the target system in order to use the configured<br />

Runtime options.<br />

■ Function<br />

Integration into automation systems<br />

Integration into SIMATIC <strong>ST</strong>EP 7/SIMOTION<br />

- Management of HMI projects within the SIMATIC Manager<br />

- Shared use of communication settings and process point<br />

definitions, i.e. symbols and messages<br />

- Display of the HMI configuring objects in the SIMATIC<br />

Manager<br />

- Transfer of configuring data via MPI/PROFIBUS/Ethernet<br />

using routing<br />

4/42<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Configuration interface<br />

Innovative engineering tools based on the latest SW<br />

technology, Microsoft.NET<br />

Comprehensive and fast access to editors and project data<br />

via Workbench applications<br />

Adaptive user interface of engineering tools depending on<br />

configured target system<br />

User-definable user interface settings, e.g., layout, toolbars,<br />

object defaults<br />

Project handling<br />

Device-independent configuration data can be used on a<br />

variety of target systems without the need for conversion;<br />

the interface adapts to the functional possibilities of the device<br />

currently configured.<br />

Cross-device utilization of common configuration data<br />

(e.g., text library) in multi-device projects<br />

Wizard-assisted definition of basic structure of HMI projects<br />

(e.g., display layout, operator prompting)<br />

Screen editor with extensive options for efficient and<br />

fast screen configuration<br />

Generation of interconnected screen objects via Drag&Drop,<br />

e.g. tags for the creation of input/output fields with process<br />

interfacing or buttons with screen selection function<br />

Template for the definition of global screen objects and<br />

functions (comparable with the Slide Master in<br />

MS PowerPoint)<br />

User-friendly editor for the creation of image blocks with<br />

defined external interface from screen objects<br />

Graphics-based configuration of motion paths<br />

Layer technology with up to 32 layers<br />

Tools for the Align, Rotate and Mirror functions<br />

Import/export<br />

of texts for translation<br />

of tags, links, text lists, and messages<br />

Generation of variable lists for importing from controller<br />

programming tools<br />

Tabular editors<br />

Quick and easy generation and modification of configuration<br />

objects of the same type, e.g. variables, texts or messages, in<br />

tabular editors<br />

Intelligent defaults, depending on previously configured data,<br />

e.g. automatic upcounting of addresses when generating<br />

consecutive variables<br />

Modification of properties by means of easy access to<br />

Properties dialog without excessive user intervention<br />

("Always on Top")<br />

Simultaneous modification of common object properties<br />

Object-based data management with user-friendly search<br />

and edit options<br />

Cross-reference list with direct access to all objects, e.g. for<br />

editing or selection<br />

Search for objects in entire project<br />

Central reassignment of variables<br />

Text search and replace functions


■ Function (continued)<br />

Project documentation<br />

Selective project documentation on printer or in file (rtf, htm,<br />

tif, txt)<br />

Libraries for predefined/user-defined configuration objects<br />

Large number of scalable and dynamizable screen objects<br />

included in scope of delivery<br />

Size-scalable WMF-format graphics for industrial applications<br />

included in scope of delivery<br />

Preview function for library objects<br />

Storage of all engineering objects in library, e.g. blocks and<br />

even entire displays or variables;<br />

picture blocks can be created on a customer- or projectspecific<br />

basis by combining simple screen objects.<br />

Changes to these picture blocks can be made centrally<br />

(block definition).<br />

Language support<br />

Multilingual project creation (max. 32 languages) in editors<br />

thanks to selectable views<br />

Automatic translation on basis of system- and user-specific<br />

dictionaries in central text library<br />

Central management of language-specific texts and graphics<br />

in libraries<br />

Edit, export and import of texts for translation<br />

Language-specific graphics<br />

Visual Basic Script support<br />

IntelliSense function for fast programming of access to<br />

runtime objects<br />

Simple creation of control sequences in script code;<br />

Script debugging in Simulator and WinCC flexible Runtime<br />

Graphics-based configuration of operator prompting<br />

Simple operator prompting concept based on hierarchical<br />

menu tree<br />

Test and startup support<br />

Simulation of HMI projects on engineering <strong>PC</strong><br />

Jump to error cause based on alarm messages in the<br />

Compiler<br />

Advanced ProSave service tool for all operating systems<br />

supported by WinCC flexible<br />

Scheduler for the definition of all global tasks<br />

Configuration of global system functions or time-driven events<br />

ChangeControl (option)<br />

Version management of project versions with rollback<br />

Logging of configuration changes, e.g. for regulated<br />

industries<br />

Note:<br />

For further information, refer to "WinCC flexible options".<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SIMATIC WinCC flexible HMI system<br />

SIMATIC WinCC flexible ES<br />

Default runtime data in engineering tools<br />

Users and passwords<br />

Recipe data records<br />

Migration of existing HMI projects<br />

Complete data transfer in projects for ProTool/Pro RT as well<br />

as 170, 270 and 370 series operator panels<br />

Conversion of configuring data on OP/TP27, e.g. to OP 277,<br />

and on OP/TP37, e.g. to MP 377<br />

Conversion of OP3 or OP7/OP17 configuring data to OP 73 or<br />

OP 77B/OP 177B<br />

Transfer of WinCC V6.2 project components (static picture<br />

components and tags only)<br />

Compatibility<br />

Integrated upward compatibility:<br />

Further processing of WinCC flexible configuration data with<br />

future versions without loss of data<br />

Integrated downward compatibility:<br />

Creation of configuration data for older versions of WinCC<br />

flexible engineering tools.<br />

System requirements<br />

(minimum requirements)<br />

WinCC flexible Engineering Software<br />

Operating system Windows XP Professional SP3 (32 bit),<br />

Windows 7 Professional, Ultimate, Enterprise<br />

(32 bit)<br />

Additionally for SIMATIC WinCC flexible<br />

Micro:<br />

Windows XP Home SP3<br />

Processor Pentium 4 (or comparable) processor running<br />

at 1.6 GHz or faster<br />

Resolution 1024 x 768 or higher<br />

Main memory (RAM) ≥ 1 GB,<br />

≥ 512 MB for WinCC flexible Micro<br />

Hard disk<br />

≥ 2 GB 2)<br />

(free memory space) 1) ≥1.2 GB for WinCC flexible Micro 3)<br />

DVD drive for software installation<br />

1) In addition to the space needed by WinCC flexible, Windows also<br />

requires space on the hard disk;<br />

e.g., for the swap file. The following formula has proven itself in the<br />

past: The size of the swap file = 3 x the size of the RAM.<br />

For further information, refer to your Windows documentation<br />

2) When installing one language. 200 MB are additionally required for<br />

each further language. In the case of different partitions for system<br />

and configuration: System partition approx. 700 MB, project partition<br />

approx. 1.3 GB.<br />

3) When installing one language. <strong>80</strong> MB are additionally required for<br />

each further language. In the case of different partitions for system<br />

and configuration: System partition approx. 600 MB, project partition<br />

approx. 600 MB.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/43<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC flexible HMI system<br />

SIMATIC WinCC flexible ES<br />

■ Ordering data Order No. Order No.<br />

WinCC flexible 2008 Advanced D<br />

incl. SP2<br />

Floating license, on DVD incl.<br />

license key, includes:<br />

Engineering software for<br />

configuring WinCC flexible<br />

Runtime on basic <strong>PC</strong>s/Panel<br />

<strong>PC</strong>s as well as Micro Panels,<br />

Basic Panels and<br />

70/170/270/370 series Panels<br />

incl. C7-635/636<br />

Software for<br />

WinCC flexible /ChangeControl<br />

engineering option<br />

6AV6 613-0AA51-3CA5<br />

1)<br />

Simulation software for WinCC<br />

flexible Runtime as well as Micro<br />

Panels, Basic Panels, and<br />

70/170/270/370 series Panels<br />

incl. C7-635/636<br />

Native drivers<br />

Electronic documentation (.pdf)<br />

in German, English, French,<br />

Italian, Spanish, simplified<br />

Chinese, traditional Chinese,<br />

Korean, Japanese<br />

WinCC flexible 2008 Standard<br />

incl. SP2<br />

Floating license, on DVD incl.<br />

license key, includes:<br />

Engineering software for<br />

configuring Micro Panels, Basic<br />

Panels and 70/170/270/370<br />

series Panels incl. C7-635/636<br />

Software for<br />

WinCC flexible /ChangeControl<br />

engineering option<br />

D 6AV6 612-0AA51-3CA5<br />

1)<br />

Simulation software for Micro<br />

Panels, Basic Panels, and<br />

70/170/270/370 series Panels<br />

incl. C7-635/636<br />

Native drivers<br />

Electronic documentation (.pdf)<br />

in German, English, French,<br />

Italian, Spanish, simplified<br />

Chinese, traditional Chinese,<br />

Korean, Japanese<br />

WinCC flexible 2008 Compact<br />

incl. SP2<br />

Floating license, on DVD incl.<br />

license key, includes:<br />

Engineering software for<br />

configuring Micro Panels,<br />

Basic Panels and 70/170 series<br />

Panels incl. C7-635<br />

Software for<br />

WinCC flexible /ChangeControl<br />

engineering option<br />

D 6AV6 611-0AA51-3CA5<br />

1)<br />

Simulation software for Micro<br />

Panels, Basic Panels, and 70/<br />

170 series Panels incl. C7-635<br />

Native drivers<br />

Electronic documentation (.pdf)<br />

in German, English, French,<br />

Italian, Spanish, simplified<br />

Chinese, traditional Chinese,<br />

Korean, Japanese<br />

4/44<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

WinCC flexible 2008 Micro<br />

incl. SP2<br />

Floating license, on DVD without<br />

license key, includes:<br />

Engineering software for<br />

configuration Micro Panels<br />

Electronic documentation (.pdf)<br />

in English, German, French,<br />

Italian, Spanish<br />

D 6AV6 610-0AA01-3CA8<br />

WinCC flexible /ChangeControl D<br />

for WinCC flexible 2008<br />

Compact/Standard/<br />

Advanced 1) 2)<br />

6AV6 613-6AA01-3AB5<br />

Floating license, option, license<br />

key only<br />

Power Packs<br />

SIMATIC WinCC flexible<br />

Power Packs<br />

Single license, license key only<br />

WinCC flexible 2008 Standard to D<br />

2008 Advanced<br />

6AV6 613-2CD01-3AD5<br />

WinCC flexible 2008 Compact to D<br />

2008 Advanced<br />

6AV6 613-2BD01-3AD5<br />

WinCC flexible 2008 Compact to D<br />

2008 Standard<br />

Upgrades<br />

SIMATIC ProTool to<br />

SIMATIC WinCC flexible 2008<br />

incl. SP2<br />

6AV6 612-2BC01-3AD5<br />

ProTool/Lite to WinCC flexible<br />

2008 Compact<br />

D 6AV6 611-3AA51-3CE5<br />

ProTool to WinCC flexible 2008 D<br />

Standard<br />

6AV6 612-3AA51-3CE5<br />

ProTool/Pro to WinCC flexible<br />

2008 Advanced<br />

SIMATIC WinCC flexible<br />

2004/2005/2007<br />

to SIMATIC WinCC flexible 2008<br />

incl. SP2<br />

D 6AV6 613-3AA51-3CE5<br />

Upgrade to WinCC flexible 2008<br />

Compact, incl. ChangeControl<br />

option 1)<br />

D 6AV6 611-0AA51-3CE5<br />

Upgrade to WinCC flexible 2008<br />

Standard, incl. ChangeControl<br />

option 1)<br />

D 6AV6 612-0AA51-3CE5<br />

Upgrade to WinCC flexible 2008<br />

Advanced, incl. ChangeControl<br />

option 1)<br />

D 6AV6 613-0AA51-3CE5<br />

Upgrade to WinCC flexible 2008<br />

Micro 3)<br />

D<br />

SIMATIC WinCC flexible ASIA<br />

2004/2005/2007<br />

to SIMATIC WinCC flexible ASIA<br />

2008 incl. SP2<br />

6AV6 610-0AA01-3CE8<br />

Upgrade to WinCC flexible 2008<br />

ASIA Standard,<br />

incl. ChangeControl option 1)<br />

D 6AV6 612-0AA11-3CE5<br />

Upgrade to WinCC flexible 2008<br />

ASIA Advanced,<br />

incl. ChangeControl option 1)<br />

D 6AV6 613-0AA11-3CE5<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

1) A separate license for WinCC flexible /ChangeControl must be<br />

purchased for each engineering station<br />

2) The ChangeControl option has not been released for integrated<br />

operation with <strong>ST</strong>EP 7<br />

3) Original delivery note or Certificate of License (CoL) from previous<br />

WinCC flexible Micro is required


HMI Software<br />

SIMATIC WinCC flexible HMI system<br />

■ Ordering data Order No. Order No.<br />

Versions for<br />

China/Taiwan/Korea/Japan<br />

WinCC flexible 2008 ASIA<br />

Standard incl. SP2<br />

Floating license, on DVD<br />

incl. license key, includes:<br />

Engineering software for<br />

configuring Micro Panels, Basic<br />

Panels and 70/170/270/370<br />

series Panels incl. C7-635/636<br />

Simulation software for Micro<br />

Panels, Basic Panels and<br />

70/170/270/370 series Panels<br />

incl. C7-635/636<br />

Native drivers<br />

Electronic documentation (.pdf)<br />

in German, English, French,<br />

Italian, Spanish, simplified<br />

Chinese, traditional Chinese,<br />

Korean, Japanese<br />

D 6AV6 612-0AA11-3CA5<br />

WinCC flexible 2008 ASIA<br />

Advanced incl. SP2<br />

Floating license, on DVD<br />

incl. license key, includes:<br />

Engineering software for<br />

configuring WinCC flexible<br />

Runtime as well as Micro Panels,<br />

Basic Panels and 70/170/270/<br />

370 series Panels<br />

incl. C7-635/636<br />

Software for<br />

WinCC flexible /ChangeControl<br />

engineering option<br />

D 6AV6 613-0AA11-3CA5<br />

1)<br />

Simulation software for WinCC<br />

flexible Runtime as well as Micro<br />

Panels, Basic Panels, and<br />

70/170/270/370 series Panels<br />

incl. C7-635/636<br />

Native drivers<br />

Electronic documentation (.pdf)<br />

in German, English, French,<br />

Italian, Spanish, simplified<br />

Chinese, traditional Chinese,<br />

Korean, Japanese<br />

■ More information<br />

Additional information is available in the Internet under:<br />

www.siemens.com/wincc-flexible<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC WinCC flexible ES<br />

Documentation<br />

(must be ordered separately)<br />

User Manual<br />

WinCC flexible Communication<br />

German 6AV6 691-1CA01-3AA0<br />

English 6AV6 691-1CA01-3AB0<br />

French 6AV6 691-1CA01-3AC0<br />

Italian 6AV6 691-1CA01-3AD0<br />

Spanish 6AV6 691-1CA01-3AE0<br />

WinCC flexible Micro<br />

User Manual<br />

German 6AV6 691-1AA01-3AA0<br />

English 6AV6 691-1AA01-3AB0<br />

French 6AV6 691-1AA01-3AC0<br />

Italian 6AV6 691-1AA01-3AD0<br />

Spanish 6AV6 691-1AA01-3AE0<br />

User Manual<br />

WinCC flexible Compact/<br />

Standard/Advanced<br />

German 6AV6 691-1AB01-3AA0<br />

English 6AV6 691-1AB01-3AB0<br />

French 6AV6 691-1AB01-3AC0<br />

Italian 6AV6 691-1AB01-3AD0<br />

Spanish 6AV6 691-1AB01-3AE0<br />

SIMATIC HMI Manual Collection B 6AV6 691-1SA01-0AX0<br />

Electronic documentation, on<br />

DVD<br />

5 languages (English, French,<br />

German, Italian, Spanish);<br />

contains: all currently available<br />

user manuals, manuals and<br />

communication manuals for<br />

SIMATIC HMI<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

1) A separate license for WinCC flexible /ChangeControl must be<br />

purchased for each engineering station<br />

Note:<br />

Do you require a specific modification or extension to the<br />

products described here? You will find information about the<br />

Open Platform Program for the creation of user-specific<br />

functions and controls for WinCC flexible under "Customized<br />

Products".<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/45<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC flexible HMI system<br />

SIMATIC WinCC flexible RT<br />

■ Overview<br />

<strong>PC</strong>-based visualization software for single-user systems directly<br />

at the machine.<br />

Runs under Windows XP Professional and Windows 7<br />

Professional, Ultimate, Enterprise<br />

Current version: SIMATIC WinCC flexible 2008 Runtime with<br />

Service Pack 2<br />

SIMATIC WinCC flexible Runtime is configured with the<br />

SIMATIC WinCC flexible Advanced configuration software.<br />

■ Benefits<br />

Optimum price/performance ratio thanks to individually<br />

scalable system functionality<br />

Functions for all visualization tasks:<br />

Operator functions, graphical and trend displays,<br />

signaling system, log system, archiving (option),<br />

recipe management (option), Audit Trail (option),<br />

process fault diagnostics (option)<br />

Flexible runtime functionality thanks to Visual Basic scripts<br />

Innovative service concepts with remote operation,<br />

diagnostics and administration via Intranet and Internet as<br />

well as e-mail communication to increase availability (option)<br />

Support for simple distributed automation solutions based on<br />

TCP/IP networks at the machine level (option)<br />

4/46<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Application<br />

SIMATIC WinCC flexible Runtime is the high-performance visualization<br />

software for simple visualization tasks at machine level.<br />

It can be used as a single-user solution for all automation applications<br />

in manufacturing automation, process automation and<br />

building services automation.<br />

SIMATIC WinCC flexible Runtime can be used in combination<br />

with the following operator panels:<br />

SIMATIC Panel <strong>PC</strong>s<br />

- <strong>PC</strong> IL 70/77<br />

- Microbox 420<br />

- Panel <strong>PC</strong> 477<br />

- Panel <strong>PC</strong> 577<br />

- Panel <strong>PC</strong> 670/677<br />

- Panel <strong>PC</strong> 870/877<br />

SIMOTION Panel <strong>PC</strong>s<br />

- P012, P015<br />

- <strong>PC</strong>R, <strong>PC</strong>R-Touch<br />

SINUMERIK Panel <strong>PC</strong>s<br />

- HT8; OP08T<br />

- OP010, OP012, OP015<br />

- TP012, TP015, OP015A<br />

Standard <strong>PC</strong>s with resolutions (W x H in pixels) of:<br />

- 4:3 format: 640 x 4<strong>80</strong>, <strong>80</strong>0 x 600, 1024 x 768, 12<strong>80</strong> x 1024,<br />

1600 x 1200<br />

- Widescreen format: 1440 x 900, 16<strong>80</strong> x 1050, 1920 x 10<strong>80</strong>,<br />

1920 x 1200<br />

■ Design<br />

SIMATIC WinCC flexible Runtime is available as a software<br />

package with 128, 512, 2048 or 4096 PowerTags. The term<br />

PowerTags is used exclusively to identify process variables<br />

and range pointers that have a process link to the controller.<br />

Variables without process link, constant limit values of variables,<br />

and messages (up to 4000 bit-triggered messages) are also<br />

available for additional system performance.<br />

The range of functions of WinCC flexible Runtime includes the<br />

centralized HMI components for visualizing and reporting, and it<br />

can be expanded to suit requirements and costs by using<br />

optional packages.<br />

SIMATIC WinCC flexible Runtime is configured with the<br />

SIMATIC WinCC flexible Advanced configuration software.


■ Function<br />

Visualization via Windows-compliant user interface<br />

made up of parameterizable screen objects and image blocks<br />

created on a project-specific basis:<br />

Numeric and alphanumeric input/output fields<br />

Static text and graphic display plus vector graphics<br />

Dynamizable graphics from HMI symbol library<br />

Bar graph, trend curve graph with scroll and zoom function as<br />

well as read line<br />

Signal-specific text and graphic lists<br />

Buttons and switches for operator-process communication<br />

Editing fields for process values (signals)<br />

Analog display, slider as example for further screen objects<br />

Project-specific image blocks created from system basic<br />

objects<br />

Graphic displays for various standard graphic formats, e.g.,<br />

bitmaps, .jpg, .wmf<br />

Alarms and messages<br />

Discrete alarms and analog alarms as well as event-driven<br />

Alarm-S/Alarm-D message procedure with SIMATIC S7 and<br />

SIMOTION<br />

Freely-definable message classes for definition of<br />

acknowledgment response and display of message events<br />

Archiving of alarms and process values 1)<br />

Archiving in files (e.g. CSV or TXT file) and Microsoft SQL<br />

databases<br />

Online evaluation of process value archives and alarm logs<br />

Evaluation of process value archives and alarm logs using<br />

standard Microsoft tools such as Excel<br />

Recipes 1)<br />

Generation of data records for machine or production data<br />

Display or entry of data records via a configurable screen<br />

object or via process images when distributed within the<br />

project<br />

Transmission of data records from or to the PLC<br />

Import/export for data records from/to CSV files<br />

Documentation of process data, alarm events and recipes<br />

Time- or event-driven report output<br />

User-definable layout<br />

Flexible expansion of system function<br />

using Visual Basic script<br />

Language support for multilingual projects<br />

Up to 16 online languages (incl. Asian and Cyrillic)<br />

Language-dependent texts and graphics<br />

Language selection during runtime<br />

User-oriented access protection according to requirements of<br />

regulated sectors<br />

Authentication with user ID and password<br />

User-group-specific rights<br />

Central system-wide user administration based on<br />

SIMATIC Logon1) Monitoring of changes by operators in runtime operation1) Recording of operator actions in an Audit Trail1) © <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SIMATIC WinCC flexible HMI system<br />

SIMATIC WinCC flexible RT<br />

PLC link for a wide variety of PLCs on-board<br />

Simultaneous connection using several protocols: O<strong>PC</strong> Client<br />

or SIMATIC HMI HTTP protocol are additive, i.e. can be used<br />

in conjunction with other PLC links<br />

Communication via native drivers and standard O<strong>PC</strong> channel<br />

Open communication between<br />

HMI systems and with higher-level systems 1)<br />

O<strong>PC</strong> server<br />

Sm@rtAccess for communication between HMI systems<br />

based on Ethernet networks, or via the intranet/Internet:<br />

Read and write access to variables;<br />

WinCC flexible Runtime or SIMATIC Panels make data<br />

(variables) available to other SIMATIC HMI systems or<br />

office applications.<br />

A SIMATIC HMI system can be used to control or monitor<br />

another system remotely;<br />

entry level for client/server configurations for distributed<br />

operator stations or for solutions with headend or control<br />

room.<br />

Sm@rtService for remote control,<br />

diagnostics and administration via intranet and Internet 1)<br />

Display and control of process images on remote <strong>PC</strong> or Panel<br />

Sending of e-mails on demand or event-driven<br />

System diagnostics visualized via device-specific HTML<br />

pages<br />

1) Option for SIMATIC WinCC flexible Runtime; runtime licenses must be<br />

purchased separately. For further information, refer to "WinCC flexible<br />

options".<br />

System requirements WinCC flexible Runtime<br />

Operating system Windows XP Professional SP3 (32 bit)<br />

Windows XP Embedded 1)<br />

Windows 7 Professional/Ultimate/Enterprise<br />

(32 bit)<br />

Processor 4)<br />

Minimum Windows XP: 300 MHz<br />

Windows 7: 1 GHz<br />

Recommended Windows XP: ≥ Pentium III, 500 MHz<br />

Windows 7: ≥ 1 GHz<br />

Graphics<br />

Minimum SVGA<br />

Resolution 640 x 4<strong>80</strong> to 1600 x 1200 or 1440 x 900,<br />

1920 x 1200<br />

RAM 2)<br />

Minimum Windows XP: 128 MB<br />

Windows 7: 1 GB<br />

Recommended Windows XP: ≥ 512 MB<br />

Windows 7: ≥ 1 GB<br />

Hard disk (free<br />

memory space) 3)<br />

≥ 250 MB<br />

1) Only for enabled platforms (e.g. Panel <strong>PC</strong> 477).<br />

You can get information from your <strong>Siemens</strong> contact.<br />

2) RAM requirements are determined primarily by the size of the<br />

graphics used.<br />

3) Without taking archives into account.<br />

In addition to the space needed by WinCC flexible, Windows also<br />

requires space on the hard disk; e.g., for the swap file. The following<br />

formula has proven itself in the past: The size of the swap file = 3 x the<br />

size of the RAM. For further information, refer to your Windows<br />

documentation<br />

4) More powerful systems (Pentium 4 and higher) may be required in<br />

order to use options<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/47<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC flexible HMI system<br />

SIMATIC WinCC flexible RT<br />

■ Integration<br />

SIMATIC WinCC flexible Runtime supports linking to:<br />

Protocol <strong>PC</strong> interfaces<br />

SIMATIC S5 via AS511 (TTY)<br />

S5-90U COM1/COM2 13)<br />

S5-90U<br />

S5-100U (CPU 100, 102, 103)<br />

S5-115U<br />

(CPU 941, 942, 943, 944, 945)<br />

S5-135U (CPU 928A, 928B)<br />

S5-155U (CPU 946/947, 948)<br />

SIMATIC S5 via PROFIBUS DP 1)<br />

S5-95U/L2-DP master CP 5512 2)<br />

CP 5611 A2 2)<br />

S5-115U<br />

(CPU 941, 942, 943, 944, 945)<br />

S5-135U (CPU 928A, 928B)<br />

S5-155U (CPU 946/947, 948)<br />

SIMATIC S7 via PPI<br />

S7-200 CP 5512 2)<br />

CP 5611 A2 2)<br />

CP 5621 1)<br />

CP 5613 A2<br />

CP 5614 A2<br />

<strong>PC</strong>/PPI adapter 3)<br />

SIMATIC S7 via MPI<br />

S7-200 (except CPU 212) 4) CP 5512 2)<br />

CP 5611 A2 2)<br />

CP 5621 1)<br />

CP 5711 2)<br />

CP 5613 A2<br />

CP 5614 A2<br />

<strong>PC</strong> adapter USB 6)<br />

S7-300<br />

S7-400<br />

WinAC Basis (V3.0 and higher)<br />

WinAC RTX<br />

Teleservice V6.1<br />

SIMATIC S7 via PROFIBUS DP 5)<br />

S7-215 4) CP 5512 2)<br />

S7-300 CPUs with integr.<br />

PROFIBUS interface<br />

S7-300 with CP 342-5<br />

S7-400 CPUs with integr.<br />

PROFIBUS interface<br />

S7-400 with CP 443-5 or IM 467<br />

WinAC Basis (V3.0 and higher)<br />

WinAC RTX<br />

SIMATIC S7 via Ethernet (TCP/IP)<br />

4/48<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

CP 5611 A2 2)<br />

CP 5621 1)<br />

CP 5711 2)<br />

CP 5613 A2<br />

CP 5614 A2<br />

S7-200 with CP 243-1 CP 1612 7)<br />

CP 1613 A2<br />

S7-300 CPUs with integral Ethernet<br />

interface<br />

S7-300 with CP 343-1<br />

S7-400 CPUs with integral Ethernet<br />

interface<br />

S7-400 with CP 443-1<br />

WinAC Basis (V3.0 and higher)<br />

WinAC RTX<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC S7 via integrated interface<br />

WinAC Basis (V2.0 and higher) Internal system interface<br />

WinAC RTX<br />

SIMATIC 505 NITP<br />

SIMATIC 500/505 RS 232/RS 422 COM1/COM2<br />

SIMATIC 505 via PROFIBUS DP<br />

SIMATIC 545/555 with CP 5434 CP 5512<br />

1) WinCC flexible Runtime is passive (DP slave); the function block<br />

required for the link is included in the scope of delivery of WinCC<br />

flexible<br />

2) For Microbox 427 and Panel <strong>PC</strong> 477/577/677 via internal MPI/DP<br />

interface<br />

3) Only point-to-point to S7-200; no configuration download, operating<br />

systems: Windows 2000/XP; Order number: 6ES7 901-3CB30-0AX0<br />

4) Constraint with regard to baud rate for S7-200; see <strong>Catalog</strong> <strong>ST</strong> 70<br />

5) WinCC flexible RT is active; communication with S7 functions<br />

6) Only point-to-point to S7-300/-400;<br />

No configuration download, operating systems: Windows 2000/XP;<br />

order number: 6ES7 972-0CB20-0XA0 (USB)<br />

7) For Microbox 427 and Panel <strong>PC</strong> 477/577/677/877 via internal Ethernet<br />

interface<br />

8) For further information, see <strong>Catalog</strong> PM 10<br />

9) "SINUMERIK HMI copy license OA" option required; for further information,<br />

see <strong>Catalog</strong> NC 60<br />

10) O<strong>PC</strong> Client is included in scope of delivery,<br />

the "WinCC flexible /O<strong>PC</strong> Server for WinCC flexible Runtime" license is<br />

required for the O<strong>PC</strong> Server option<br />

11) "WinCC flexible /Sm@rtAccess for WinCC flexible Runtime" license<br />

required<br />

12) O<strong>PC</strong> and HTTP communication are additive, i.e. can be used in<br />

conjunction with the PLC links listed above<br />

13) Via <strong>PC</strong> cable with integrated level converter RS 232/TTY; Order<br />

number: 6ES5 734-1BD20<br />

For information about SIMATIC Panels that support O<strong>PC</strong>/http<br />

communication, see the overview under "System interfaces".<br />

2)<br />

CP 5611 A2 2)<br />

SIMOTION 8)<br />

SINUMERIK9) Third-party controllers<br />

Allen Bradley (DF1/DH485) COM1/COM2<br />

Allen Bradley (Ethernet) CP 1612 7)<br />

GE Fanuc (SNP/SNPX) COM1/COM2<br />

LG GLOFA GM COM1/COM2<br />

Mitsubishi (FX/MP4) COM1/COM2<br />

Modicon (Modbus) COM1/COM2<br />

Modicon (Modbus TCP/IP) CP 1612 7)<br />

OMRON (Link/Multilink) COM1/COM2<br />

O<strong>PC</strong> 10) 12)<br />

Data Access V2.05a (client + CP 1612<br />

server)<br />

7)<br />

Data Access XML V1.00 (client)<br />

HTTP communication for data CP 1612<br />

exchange between SIMATIC HMI<br />

(client + server) 11) 12)<br />

7)<br />

Protocol <strong>PC</strong> interfaces


■ Integration (continued)<br />

Application note<br />

In parallel with each and every PLC link, WinCC flexible Runtime<br />

supports the use of the O<strong>PC</strong> Client channel; this enables, for<br />

example, connection to an SNMP O<strong>PC</strong> Server for the purpose of<br />

visualizing the data stored there. The SNMP O<strong>PC</strong> Server<br />

provides a means of monitoring network components of any type<br />

(e.g. switches) which support the SNMP protocol. For further<br />

information, see <strong>Catalog</strong> IK PI.<br />

Higher level visualization system<br />

Industrial Ethernet<br />

On-site visualization<br />

PROFIBUS<br />

SIMATIC WinCC flexible Runtime application example<br />

O<strong>PC</strong> Server<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SIMATIC WinCC flexible HMI system<br />

SIMATIC WinCC flexible RT<br />

Note:<br />

For further information,<br />

see "Operator control and monitoring/System interfaces"<br />

O<strong>PC</strong> Client<br />

SIMATIC S7-300 SIMATIC S7-400<br />

O<strong>PC</strong> Server<br />

O<strong>PC</strong> Client<br />

3rd party<br />

O<strong>PC</strong> Server<br />

Non-<strong>Siemens</strong><br />

PLCs<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00077<br />

4/49<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC flexible HMI system<br />

SIMATIC WinCC flexible RT<br />

■ Technical specifications<br />

Type SIMATIC WinCC flexible<br />

Runtime<br />

The specifications are maximum<br />

values<br />

Displays 500<br />

Fields per screen 400<br />

Variables per screen 400<br />

Static text 30,000<br />

Graphics objects 2,000<br />

Complex objects per display<br />

(e.g. bars)<br />

40<br />

Trends <strong>80</strong>0<br />

Graphics lists 1) 500<br />

Text lists 1) 500<br />

Number of entries in symbol tables 3,500<br />

Variables 4,096 3)<br />

Messages bit-triggered / analog 4,000 / 500<br />

Message text (number of<br />

characters)<br />

<strong>80</strong><br />

Number of process values per<br />

message<br />

8<br />

Size of message buffer 1,024<br />

Pending message events 500<br />

Archives 4) 100<br />

Archivable data Process data,<br />

messages<br />

Max. number of entries per archive<br />

(incl. all archive segments)<br />

500,000<br />

Archive types Short-term archive, sequence<br />

archive (max. 400 per archive)<br />

Data storage format CSV (Comma Separated<br />

Variable),<br />

RDB (Runtime Data Base),<br />

interface to MS SQL database<br />

1) Together only 500 text and graphics lists<br />

2) Dependent on memory medium used<br />

3) Dependent on number of licensed PowerTags<br />

4) Option for SIMATIC WinCC flexible Runtime.<br />

For further information, refer to "WinCC flexible options".<br />

4/50<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Recipes 4) 1,000<br />

Elements per recipe 2,000 3)<br />

Data records per recipe 5,000 2)<br />

Type SIMATIC WinCC flexible<br />

Runtime<br />

Password protection<br />

User rights 32<br />

Number of user groups 50<br />

Visual Basic scripts 200<br />

Online languages, max.<br />

Communication<br />

16<br />

SIMATIC S7 MPI interface/<br />

PROFIBUS DP interface<br />

Number of connectable stations,<br />

max.<br />

SIMATIC S7 PPI interface<br />

Number of connectable stations,<br />

max.<br />

SIMATIC S5<br />

PROFIBUS DP interface<br />

Number of connectable stations,<br />

max.<br />

Depending on the scope of the<br />

configuration (communication)<br />

from the point of view of<br />

WinCC flexible Runtime, as many<br />

as 8 connections are possible<br />

1 from viewpoint of WinCC flexible<br />

Runtime<br />

1 from viewpoint of<br />

WinCC flexible Runtime<br />

Multi-protocol operation Yes, O<strong>PC</strong> Client or SIMATIC HMI<br />

HTTP protocol are additive, i.e.<br />

can be used in conjunction with<br />

other PLC links


HMI Software<br />

SIMATIC WinCC flexible HMI system<br />

■ Ordering data Order No. Order No.<br />

SIMATIC WinCC flexible 2008<br />

Runtime<br />

for <strong>PC</strong> systems; incl. SW for<br />

<strong>PC</strong> systems options 1)<br />

Single license, on CD-ROM<br />

incl. licensing, for:<br />

128 PowerTags (RT 128) D 6AV6 613-1BA51-3CA0<br />

512 PowerTags (RT 512) D 6AV6 613-1DA51-3CA0<br />

2048 PowerTags (RT 2048) D 6AV6 613-1FA51-3CA0<br />

4096 PowerTags (RT 4096)<br />

Power Packs<br />

SIMATIC WinCC flexible 2008<br />

Runtime<br />

Single license, only license key<br />

for PowerTags, from<br />

D 6AV6 613-1GA51-3CA0<br />

128 to 512 PowerTags D 6AV6 613-4BD01-3AD0<br />

128 to 2048 PowerTags D 6AV6 613-4BF01-3AD0<br />

512 to 2048 PowerTags D 6AV6 613-4DF01-3AD0<br />

128 to 4096 PowerTags D 6AV6 613-4BG01-3AD0<br />

512 to 4096 PowerTags D 6AV6 613-4DG01-3AD0<br />

2048 to 4096 PowerTags<br />

Upgrades<br />

SIMATIC ProTool/Pro RT to<br />

SIMATIC WinCC flexible 2008<br />

D 6AV6 613-4FG01-3AD0<br />

ProTool/Pro Runtime<br />

128 PowerTags to<br />

WinCC flexible 2008 Runtime<br />

128 PowerTags 2)<br />

D 6AV6 613-3BB51-3CE0<br />

ProTool/Pro Runtime<br />

256 PowerTags to<br />

WinCC flexible 2008 Runtime<br />

512 PowerTags 2)<br />

D 6AV6 613-3CD51-3CE0<br />

ProTool/Pro Runtime<br />

512 PowerTags to<br />

WinCC flexible 2008 Runtime<br />

512 PowerTags 2)<br />

D 6AV6 613-3DD51-3CE0<br />

ProTool/Pro Runtime<br />

2048 PowerTags to<br />

WinCC flexible 2008 Runtime<br />

2048 PowerTags 2)<br />

D 6AV6 613-3FF51-3CE0<br />

SIMATIC WinCC flexible<br />

2004/2005/2007 Runtime to<br />

SIMATIC WinCC flexible 2008<br />

Runtime<br />

Upgrade to SIMATIC WinCC<br />

flexible Runtime 2008<br />

PowerTags incl. Runtime<br />

Options for:<br />

- WinCC flexible /Archives<br />

- WinCC flexible /Recipes<br />

- WinCC flexible /Audit<br />

- WinCC flexible /Sm@rtAccess<br />

- WinCC flexible /Sm@rtService<br />

- WinCC flexible /O<strong>PC</strong> server<br />

- WinCC flexible /ProAgent<br />

D 6AV6 613-1XA51-3CE0<br />

1) Runtime licenses for WinCC flexible Runtime options must be<br />

purchased separately for each target system.<br />

2) each including a single license WinCC flexible /Archives and WinCC<br />

flexible /Recipes<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC WinCC flexible RT<br />

SIMATIC WinCC flexible<br />

2004/2005/2007 Runtime to<br />

SIMATIC WinCC flexible 2008<br />

Runtime (continued)<br />

Upgrade of the SIMATIC WinCC D 6AV6 618-7XX01-3AF0<br />

flexible Panel options:<br />

- WinCC flexible /Audit for<br />

SIMATIC Panel<br />

- WinCC flexible /Sm@rtAccess<br />

for SIMATIC Panel<br />

- WinCC flexible /Sm@rtService<br />

for SIMATIC Panel<br />

- WinCC flexible /O<strong>PC</strong> server for<br />

SIMATIC Multi Panel<br />

- WinCC flexible /ProAgent for<br />

SIMATIC Multi Panel<br />

Documentation<br />

(must be ordered separately)<br />

User Manual<br />

WinCC flexible Runtime<br />

German 6AV6 691-1BA01-3AA0<br />

English 6AV6 691-1BA01-3AB0<br />

French 6AV6 691-1BA01-3AC0<br />

Italian 6AV6 691-1BA01-3AD0<br />

Spanish 6AV6 691-1BA01-3AE0<br />

User Manual<br />

WinCC flexible communication<br />

German 6AV6 691-1CA01-3AA0<br />

English 6AV6 691-1CA01-3AB0<br />

French 6AV6 691-1CA01-3AC0<br />

Italian 6AV6 691-1CA01-3AD0<br />

Spanish 6AV6 691-1CA01-3AE0<br />

SIMATIC HMI Manual Collection B 6AV6 691-1SA01-0AX0<br />

Electronic documentation,<br />

on DVD<br />

5 languages (English, French,<br />

German, Italian and Spanish);<br />

contains: all currently available<br />

user manuals, manuals and<br />

communication manuals for<br />

SIMATIC HMI<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/51<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC flexible HMI system<br />

SIMATIC WinCC flexible RT<br />

■ Ordering data Order No. Order No.<br />

Communication via Industrial<br />

Ethernet<br />

CP 1613-A2<br />

<strong>PC</strong>I card (32 bit) for connecting a<br />

PG/<strong>PC</strong> to Industrial Ethernet<br />

(communications software must<br />

be ordered separately)<br />

SIMATIC NET IE S7-1613 V8.0<br />

SP1<br />

Software for S7 and open<br />

communication, incl. PG/OP<br />

communication, O<strong>PC</strong> server and<br />

NCM <strong>PC</strong>; up to 120 connections,<br />

runtime software, software and<br />

electronic manual on CD-ROM,<br />

license key on USB flash drive,<br />

Class A, for 32-bit Windows 7<br />

Professional/Ultimate for up to<br />

4 CP 1613/CP 1613 A2 /<br />

CP 1623; German/English<br />

6GK1 161-3AA01<br />

Single license for 1 installation D 6GK1 716-1CB<strong>80</strong>-3AA0<br />

Software Update Service for one D<br />

year, with automatic extension;<br />

requirement: Current software<br />

version<br />

6GK1 716-1CB00-3AL0<br />

Upgrade S7-1613 from V6.4 to<br />

S7-1613 V8.0 SP1<br />

D 6GK1 716-1CB00-3AE0<br />

Upgrade S7-1613 from V6.0,<br />

V6.1, V6.2 or V6.3 to S7-1613<br />

V8.0 SP1<br />

D 6GK1 716-1CB00-3AE1<br />

Communication via PROFIBUS<br />

CP 5613-A2 6GK1 561-3AA01<br />

<strong>PC</strong>I card (32-bit) for connecting a<br />

<strong>PC</strong> to PROFIBUS<br />

(communications software must<br />

be ordered separately).<br />

CP 5614-A2 6GK1 561-4AA01<br />

<strong>PC</strong>I card (32-bit) for connecting a<br />

<strong>PC</strong> to PROFIBUS<br />

(communications software must<br />

be ordered separately).<br />

SIMATIC NET PB S7-5613 V8.0<br />

SP1<br />

Software for S7 communication,<br />

incl. PG and FDL protocol,<br />

O<strong>PC</strong> server and NCM <strong>PC</strong>;<br />

runtime software, software and<br />

electronic manual on<br />

USB flash drive, license key on<br />

diskette, Class A, for 32-bit<br />

Windows 7 Professional/Ultimate<br />

for up to 4 CP 5613 A2, CP5614<br />

A2, CP 5603 / CP 5623 / CP 5624;<br />

■ More information<br />

Additional information is available in the Internet under:<br />

www.siemens.com/wincc-flexible<br />

4/52<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC NET PB S7-5613 V8.0<br />

SP1 (continued)<br />

Single license for 1 installation D 6GK1 713-5CB<strong>80</strong>-3AA0<br />

Software Update Service for one D<br />

year, with automatic extension;<br />

requirement: Current software<br />

version<br />

6GK1 713-5CB00-3AL0<br />

Upgrade S7-5613 from V6.4 to<br />

S7-5613 V8.0 SP1<br />

D 6GK1 713-5CB00-3AE0<br />

Upgrade S7-5613 from V6.0,<br />

V6.1, V6.2 or V6.3 to S7-5613<br />

V8.0 SP1<br />

D 6GK1 713-5CB00-3AE1<br />

CP 5512<br />

<strong>PC</strong>MCIA card (32-bit CARDBUS)<br />

for connecting a PG/Notebook to<br />

PROFIBUS or MPI<br />

(communications software<br />

included in WinCC flexible)<br />

6GK1 551-2AA00<br />

CP 5611-A2<br />

<strong>PC</strong>I card (32-bit) for connecting a<br />

PG/<strong>PC</strong> to PROFIBUS<br />

(communications software<br />

included in WinCC flexible basic<br />

package)<br />

6GK1 561-1AA01<br />

CP 5611 MPI<br />

Comprising CP 5611 A2 (32-bit)<br />

and MPI cable, 5 m<br />

A 6GK1 561-1AM01<br />

CP 5621<br />

<strong>PC</strong>I Express X1 card (32-bit) for<br />

connection of PG/<strong>PC</strong> to<br />

PROFIBUS or MPI<br />

(communications software<br />

included in WinCC flexible basic<br />

package)<br />

E 6GK1 562-1AA00<br />

CP 5711<br />

USB adapter (USB V2.0) for<br />

connecting a PG or Notebook to<br />

PROFIBUS or MPI<br />

(2 m USB cable and<br />

5 m MPI cable included)<br />

A 6GK1 571-1AM00<br />

<strong>PC</strong>/PPI adapter 6ES7 901-3CB30-0XA0<br />

RS 232, 9-pin; male with RS 232/<br />

PPI converter, max. 19.2 kbit/s<br />

<strong>PC</strong> adapter USB 6ES7 972-0CB20-0XA0<br />

For use with Windows 2000/XP<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

Note:<br />

Do you need a specific modification or option for the products<br />

described here? You will find information about the Open<br />

Platform Program for the creation of user-specific functions and<br />

controls for WinCC flexible under "Customized Products".


■ Overview<br />

Option for SIMATIC WinCC flexible Engineering<br />

SIMATIC WinCC flexible /ChangeControl<br />

WinCC flexible /ChangeControl enables consistent backup of<br />

configuration data. The history of changes can be verified down<br />

to the last detail for applications requiring interruption-free proof<br />

for the complete life cycle of a product.<br />

Delivered customer projects, approved reference states or<br />

development stages are managed in a database.<br />

Changes to project data can be integrated without problem<br />

into the version management using new versions.<br />

A rollback is possible at any time.<br />

Options for SIMATIC Panels/Multi Panels and<br />

SIMATIC WinCC flexible Runtime<br />

SIMATIC WinCC flexible /Archives<br />

Archiving of alarms and process values<br />

Archiving in files (e.g. CSV file) and Microsoft SQL databases<br />

Online evaluation of process value archives and alarm logs<br />

Evaluation of process value archives and alarm logs using<br />

standard MS tools such as Excel<br />

SIMATIC WinCC flexible /Recipes<br />

Generation and management of data records for machine or<br />

production data<br />

Display or entry of data records via a configurable screen<br />

object or via process images when distributed within the<br />

project<br />

Transmission of data records from or to the controller<br />

Import/export of data sets as CSV files<br />

SIMATIC WinCC flexible /Audit<br />

Recording of operator actions in an Audit Trail<br />

Electronic signature for important operator actions relevant to<br />

production<br />

The ChangeControl option supports users in respect of<br />

tracking modifications to projects<br />

Audit supports users in meeting special quality requirements,<br />

e.g.<br />

- Production plant requiring validation according to<br />

21 CFR Part 11 (Food Drug Administration law)<br />

- In respect of traceability according to EU 175/2002<br />

(EU directive)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SIMATIC WinCC flexible options<br />

SIMATIC Logon for WinCC flexible<br />

SIMATIC WinCC flexible options<br />

Option for connecting <strong>PC</strong>s with SIMATIC WinCC flexible Runtime<br />

and SIMATIC Panels to central user administration.<br />

Creates user administration on a central computer to which<br />

one or more WinCC flexible stations can be connected over<br />

Ethernet.<br />

With each logging-on/off of a user on one of the connected<br />

stations, SIMATIC Logon checks whether a user password has<br />

been created and that the required privileges exist.<br />

SIMATIC Logon for WinCC flexible supports the user in<br />

combination with the options /Audit and /ChangeControl in<br />

meeting requirements in accordance with FDA 21 CFR Part 11<br />

and EU178.<br />

SIMATIC WinCC flexible /Sm@rtAccess<br />

Flexible solution for access to HMI systems and process data<br />

from any location<br />

Communication between different SIMATIC HMI systems<br />

SIMATIC WinCC flexible /Sm@rtService<br />

Remote maintenance and servicing of machines and plant via<br />

Internet/Intranet<br />

Reduced downtimes for machines and plant with direct<br />

remote access<br />

Flexible solution for remote access to machines and plant<br />

SIMATIC WinCC flexible /O<strong>PC</strong> server<br />

Incorporation of automation components from different<br />

vendors into a single automation concept<br />

Communication for data exchange between HMI systems<br />

and/or higher-level control system<br />

Communication with applications from different vendors, e.g.<br />

MES, ERP or applications in the office sector<br />

SIMATIC WinCC flexible /ProAgent<br />

Precise and rapid process fault diagnostics in plant and<br />

machines for SIMATIC S7 and SIMATIC HMI<br />

Standardized diagnostics concept for various SIMATIC<br />

components<br />

No further configuration overhead for diagnostics functionality<br />

Frees up PLC capacity with regard to memory and program<br />

execution time<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/53<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC flexible options<br />

WinCC flexible /ChangeControl<br />

■ Overview<br />

Options for the versioning of configuration data and for tracing<br />

configuration changes (e.g. as verification in regulated<br />

sectors)<br />

For the engineering tool SIMATIC WinCC flexible<br />

Compact/Standard/Advanced<br />

One license is required for each configuration computer<br />

■ Benefits<br />

Consistent backup of configuration data<br />

- Delivered versions, approved reference states or<br />

development stages are managed in a database.<br />

- Changes to project data can be integrated without problem<br />

into the version management using new versions. A rollback<br />

is possible at any time.<br />

Tracing of configuration changes<br />

- The history of changes can be verified down to the last detail<br />

for applications requiring interruption-free proof for the<br />

complete life cycle of a product.<br />

4/54<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Application<br />

In machine/special machine construction for project<br />

management, e.g. delivered customer versions and their<br />

modifications<br />

For saving of intermediate states during complex new<br />

developments or expansions, with rollback facility<br />

During work for specific orders as basis for calculating costs<br />

for modifications<br />

In regulated sectors as proof of state of plants or machines<br />

and any modifications made to them<br />

■ Function<br />

Integral GUI for management of project versions (version tree<br />

with main line and secondary lines for modified project<br />

versions)<br />

Modification log can be activated/deactivated and shows who<br />

carried out modifications, and when/which. Modification<br />

reasons can be entered as comments.<br />

■ Ordering data Order No.<br />

WinCC flexible /ChangeControl<br />

for WinCC flexible 2008<br />

Compact/Standard/Advanced 1)<br />

D 6AV6 613-6AA01-3AB5<br />

Floating License, option,<br />

license key only<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

1) The ChangeControl option has not been released for integrated<br />

operation with <strong>ST</strong>EP 7.<br />

■ More information<br />

Note:<br />

Do you need a specific modification or option for the products<br />

described here? Then look up "Customized products", where<br />

you will find information about the Open Platform Program for the<br />

creation of user-specific functions and controls for<br />

WinCC flexible.


■ Overview<br />

Option for SIMATIC WinCC flexible Runtime for archiving<br />

process values and messages<br />

Archiving of process values and messages supports<br />

the acquisition and processing of process data from an<br />

industrial plant or machine. Evaluation of the archived process<br />

data provides information about the operating states of the<br />

plant or machine<br />

One license is required per operator station<br />

(no license is required for SIMATIC Panels/Multi Panels)<br />

■ Benefits<br />

Message and process value archives permit foresighted<br />

diagnostics which prevents downtimes<br />

Early detection of danger or fault states<br />

Increase in product quality and productivity thanks to regular<br />

evaluation of process value and message archives<br />

■ Application<br />

Further use of archives for evaluation and long-term archiving<br />

Record of repeated fault states<br />

Optimization of maintenance cycles<br />

Ensured quality standards<br />

Control of quality as well as production capacity utilization<br />

Documentation of process sequence<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SIMATIC WinCC flexible options<br />

WinCC flexible /Archives<br />

■ Function<br />

Time-controlled as well as manual or process-controlled<br />

swapping out of process data and messages for long-term<br />

archiving<br />

During runtime, swapped out data are read in and selectively<br />

analyzed using WinCC flexible Runtime<br />

- Presentation and evaluation of archived process data based<br />

on a configurable trend display. Reading of the values is<br />

facilitated by a read line.<br />

- Presentation and evaluation of archived alarms based on a<br />

configurable alarm view.<br />

- User-friendly navigation in the archives.<br />

External evaluation of the archives using MS standard tools<br />

Various archive types are supported: sequence and shortterm<br />

archives<br />

Archiving of process values and messages on external,<br />

Windows-supported storage media<br />

-CSV files<br />

-RDB files<br />

- Microsoft SQL server via ODBC<br />

Power standard functions permit user-friendly and flexible<br />

utilization of the archives<br />

■ Technical specifications<br />

Type WinCC flexible /Archives<br />

The specifications are maximum<br />

values<br />

Execution platform SIMATIC WinCC flexible Runtime<br />

Archives 100<br />

Archivable data Process values, messages<br />

Cyclical trigger for archiving 1 s<br />

process values (variables)<br />

Max. number of entries per archive 500,000<br />

(incl. sequence archive)<br />

1)<br />

Archive types Circulating archive<br />

Sequence archive (max. 400 per<br />

archive)<br />

Data storage format CSV (Comma Separated<br />

Variable),<br />

RDB (Runtime Data Base) and<br />

interface to Microsoft SQL<br />

database (database not included<br />

in scope of delivery)<br />

1) Dependent on memory medium used<br />

■ Ordering data Order No.<br />

WinCC flexible /Archives for D<br />

WinCC flexible 2008 Runtime 1)<br />

Single License, license key only<br />

6AV6 618-7ED01-3AB0<br />

WinCC flexible /Archives+<br />

Recipes for WinCC flexible 2008<br />

Runtime 1)<br />

D 6AV6 618-7GD01-3AB0<br />

Single License for each option,<br />

license key only<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

1) One license is required for each operator station. A license is not<br />

required for the engineering system for configuring the runtime option.<br />

■ More information<br />

Note:<br />

Do you need a specific modification or option for the products<br />

described here? Then look up "Customized products", where<br />

you will find information about the Open Platform Program for the<br />

creation of user-specific functions and controls for WinCC<br />

flexible.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/55<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC flexible options<br />

WinCC flexible /Recipes<br />

■ Overview<br />

Option for SIMATIC WinCC flexible Runtime for managing data<br />

records in recipes that contain related machine or production<br />

data<br />

The data in a data set can be transferred, for example, from<br />

the operator panel to the PLC to switch production to a<br />

different product version<br />

One license is required per operator station (no license is<br />

required for SIMATIC Panels/Multi Panels)<br />

■ Benefits<br />

Generation and management of machine parameters and<br />

production data on the basis of data sets, and exchange with<br />

the automation equipment, e.g. with the machine<br />

Clear tabular representation of data elements with support of<br />

a configurable graphic object, or representation in<br />

technological relationships for several process graphics<br />

Simple operator prompting using standard functions<br />

Export/import of data sets for further processing with other<br />

tools (e.g. MS Excel)<br />

■ Application<br />

Assignment of plant/machine parameters in the production<br />

industry<br />

Batch-oriented production, e.g. in the food or plastics industry<br />

4/56<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Function<br />

Input of data sets (e.g. operating parameters for a machine,<br />

production data for a plastics processing machine) in<br />

WinCC flexible Runtime, their storage, and passing on<br />

to the PLC<br />

Display and input of data sets using a configurable graphics<br />

object, or distributed among several process displays within<br />

the project<br />

Data set elements are coupled to the process using direct<br />

linking of the variables<br />

Transmission of data records from or to the PLC<br />

Powerful interfaces permit synchronized exchange of data<br />

with the PLC<br />

Saving of data sets on local media or on remote data servers<br />

via networks<br />

Import/export of data sets as CSV files<br />

Logging of data sets, e.g. as batch report/shift report<br />

Convenient and flexible management of data sets using<br />

powerful standard functions<br />

WinCC flexible recipes and the associated data sets are<br />

conveniently created using a separate editor in the WinCC<br />

flexible Advanced engineering tool, and assigned default data.<br />

A configurable table object is used to display the data during<br />

runtime. Furthermore, the individual data set elements can also<br />

be directly output for several process displays on the basis of<br />

standard input/output boxes. The data can therefore be clearly<br />

presented for the operator in technological layers.<br />

■ Technical specifications<br />

Type WinCC flexible /Recipes<br />

The specifications are maximum<br />

values<br />

Execution platform SIMATIC WinCC flexible Runtime<br />

Recipes 1000<br />

Entries per recipe 2000 1)<br />

Data records per recipe 5000 2)<br />

User data length in bytes per data<br />

record<br />

<strong>80</strong>00 KB 2)<br />

1) Dependent on number of licensed PowerTags<br />

2) Dependent on memory medium used<br />

■ Ordering data Order No.<br />

WinCC flexible /Recipes for D<br />

WinCC flexible 2008 Runtime 1)<br />

Single License, license key only<br />

6AV6 618-7FD01-3AB0<br />

WinCC flexible /Archives+<br />

Recipes for WinCC flexible 2008<br />

Runtime 1)<br />

D 6AV6 618-7GD01-3AB0<br />

Single License for each option,<br />

license key only<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

1) One license is required for each operator station.<br />

A license is not required for the engineering system for configuring the<br />

runtime option.<br />

■ More information<br />

Note:<br />

Do you need a specific modification or option for the products<br />

described here? Then look up "Customized products", where<br />

you will find information about the Open Platform Program for the<br />

creation of user-specific functions and controls for WinCC<br />

flexible.


■ Overview<br />

Option for SIMATIC WinCC flexible Runtime as well as<br />

SIMATIC Panels for recording operations in an audit trail, and<br />

electronic signature<br />

The audit trail features a safety mechanism that indicates<br />

subsequent manipulation.<br />

An easy-to-use configuration option included as standard in<br />

WinCC flexible enables you to set:<br />

- the operator actions to be recorded in the audit trail during<br />

runtime<br />

- the important operator actions requiring electronic signature/<br />

comments during runtime<br />

The audit option combined with the<br />

WinCC flexible ES ChangeControl option supports the user<br />

with plant validation<br />

Available for the following SIMATIC HMI systems: TP/OP 270,<br />

TP/OP 277, MP 270B, MP 277, MP 370, MP 377,<br />

WinCC flexible Runtime<br />

A license is required for every operator control unit<br />

(panel or <strong>PC</strong>)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

HMI Software<br />

SIMATIC WinCC flexible options<br />

WinCC flexible /Audit<br />

Audit supports the user in meeting special quality<br />

requirements, e.g.,<br />

- production plant requiring validation according to<br />

21 CFR Part 11 FDA 2)<br />

- in respect of traceability according to EU 175/2002 3)<br />

Entries in the audit trail are allocated to individual users. This<br />

ensures that responsibilities can be clearly identified.<br />

The audit trail, stored as a CSV file 1) , can be checked via a<br />

security mechanism to find out if subsequent changes have<br />

been made.<br />

For particularly important user actions, e.g. starting<br />

production or loading new recipes, electronic signatures and<br />

comments can be configured and then called up and logged<br />

during runtime.<br />

1) CSV Comma Separated Values<br />

2) The FDA (Food and Drug Administration) is the American public<br />

health authority<br />

3) 21 CFR Part 11- law on plant validation<br />

■ Technical specifications<br />

WinCC flexible /Audit<br />

Archive for Audit Trail use on the Plug-in flash memory card on<br />

Panel<br />

the panel<br />

In the higher-level <strong>PC</strong> (memory<br />

medium) connected to the panel<br />

via Ethernet<br />

Archive for Audit Trail use of WinCC On the <strong>PC</strong> (storage medium)<br />

flexible Runtime<br />

Execution platform<br />

SIMATIC Panels Mobile Panel 277, TP/OP 270,<br />

TP/OP 277<br />

SIMATIC Multi Panels MP 270B, MP 277, MP 370,<br />

MP 377<br />

<strong>PC</strong>s SIMATIC WinCC flexible Runtime<br />

■ Ordering data Order No.<br />

WinCC flexible /Audit for<br />

SIMATIC Panel<br />

Single License, license key only<br />

WinCC flexible /Audit for<br />

WinCC flexible Runtime 2008<br />

Single License, license key only<br />

D 6AV6 618-7HB01-3AB0<br />

D 6AV6 618-7HD01-3AB0<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

■ More information<br />

Note:<br />

Do you need a specific modification or option for the products<br />

described here? Then look up "Customized products", where<br />

you will find information about the Open Platform Program for the<br />

creation of user-specific functions and controls for WinCC<br />

flexible.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/57<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC flexible options<br />

SIMATIC Logon for WinCC flexible<br />

■ Overview<br />

Option for connecting <strong>PC</strong>s with SIMATIC WinCC flexible<br />

Runtime and SIMATIC Panels to central user administration.<br />

Creates user administration on a central computer to which<br />

one or more WinCC flexible stations can be connected over<br />

Ethernet network.<br />

With each logging-on/off of a user on one of the connected<br />

stations, SIMATIC Logon checks whether a user password has<br />

been created and that the required privileges exist.<br />

SIMATIC Logon for WinCC flexible supports the user in<br />

combination with the /Audit and /ChangeControl options in<br />

meeting requirements in accordance with FDA 21 CFR Part 11<br />

and EU178.<br />

Licensing:<br />

SIMATIC Logon (basic license) and<br />

SIMATIC Logon Remote Access (3-pack license) for<br />

connection of 3 WinCC flexible stations to a central user<br />

administration. Additional stations can be connected by using<br />

further SIMATIC Logon Remote Access licenses<br />

(3-pack/10-pack).<br />

■ Benefits<br />

Centralized configuration of all access authorizations of a<br />

distributed system avoids unnecessary travel times. Timeconsuming<br />

multiple configurations for each individual local<br />

station become unnecessary. Accordingly, users can be<br />

easily configured from a central location.<br />

All access data apply throughout the plant on every<br />

connected station. Additional access data on local<br />

subsystems is no longer necessary.<br />

4/58<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Design<br />

SIMATIC Logon and SIMATIC Logon Remote Access are<br />

installed on a central station.<br />

The following WinCC flexible stations are connected to the<br />

central station via Ethernet network:<br />

<strong>PC</strong>s with WinCC flexible Runtime<br />

SIMATIC Panels from the 177 series or higher (panels with<br />

Ethernet interface)<br />

Licensing<br />

The following licenses are required:<br />

SIMATIC Logon basic license<br />

SIMATIC Logon Remote Access license<br />

(3-pack license 10-pack license); more than one<br />

SIMATIC Logon Remote Access license can be installed.<br />

The number of connectable stations depends on the<br />

SIMATIC Logon Remote Access licenses used. This number is<br />

the total of the connections provided by the individual licenses.<br />

As an example: Two installed licenses for 10 enable the<br />

connection of 20 stations to the central station.<br />

■ Function<br />

Configuration<br />

In the first step, the following data must be saved in the user<br />

administration of WinCC flexible on every WinCC flexible station<br />

in the plant:<br />

Required user groups with associated user privileges<br />

IP address, port number, Windows domain of the central<br />

station on which the central user administration is stored.<br />

All user groups are configured with the same names in the<br />

central user administration. All users are created here, and have<br />

automatic access to the connected WinCC flexible stations in<br />

accordance with the relevant user group.<br />

If the connection fails between the central station with SIMATIC<br />

Logon and a WinCC flexible station, the operation is handled<br />

through an "emergency user" which must first be preconfigured<br />

locally.<br />

Intervals for password aging and regulations for the structure of<br />

a password are defined according to the configuration on the<br />

central station and then also apply to all decentrally connected<br />

WinCC flexible stations or the respective users.<br />

■ Technical specifications<br />

SIMATIC Logon for WinCC<br />

flexible<br />

Execution platform<br />

SIMATIC Panels Mobile Panel 177 PN;<br />

Mobile Panel 277,<br />

TP/OP 177B PN/DP, TP/OP 277<br />

SIMATIC Multi Panels MP 177, MP 277, MP 377<br />

<strong>PC</strong>s WinCC flexible Runtime


© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SIMATIC WinCC flexible options<br />

SIMATIC Logon for WinCC flexible<br />

■ Ordering data Order No. ■ More information<br />

SIMATIC Logon V1.4 incl. SP2 6ES7 658-7BX41-2YA0<br />

Note:<br />

Basic license;<br />

single license for 1 installation,<br />

7 languages (German, English,<br />

French, Spanish, Italian, Chinese,<br />

Japanese);<br />

type of delivery:<br />

CD, license key disk, Certificate<br />

of License, Terms and Conditions<br />

For connecting WinCC flexible<br />

clients, the corresponding<br />

number of additional SIMATIC<br />

logon remote access licenses is<br />

required.<br />

Do you need a specific modification or addition to the products<br />

described here? Then take a look under "Customer-specific<br />

products". There, we provide information on the Open Platform<br />

Program for creating your own functions or Controls for WinCC<br />

flexible.<br />

SIMATIC Logon Remote Access<br />

for WinCC flexible (3 clients)<br />

Remote access for 3 WinCC<br />

flexible 2008 clients;<br />

single license for 3 remote access<br />

clients;<br />

type of delivery:<br />

CD, license key disk, Certificate<br />

of License, Terms and Conditions<br />

The number of licensed clients is<br />

determined based on the amount<br />

of installed SIMATIC logon remote<br />

access licenses.<br />

6ES7 658-7BA00-2YB0<br />

SIMATIC Logon Remote Access<br />

for WinCC flexible (10 clients)<br />

Remote access for<br />

10 WinCC flexible 2008 clients;<br />

single license for<br />

10 remote access clients;<br />

type of delivery:<br />

CD, license key disk, Certificate<br />

of License, Terms and Conditions<br />

The number of licensed clients is<br />

determined based on the amount<br />

of installed SIMATIC logon remote<br />

access licenses.<br />

6ES7 658-7BB00-2YB0<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/59<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC flexible options<br />

WinCC flexible /Sm@rtAccess<br />

■ Overview<br />

■ Benefits<br />

Option for SIMATIC WinCC flexible Runtime plus SIMATIC<br />

Panels for communication between various SIMATIC HMI<br />

systems.<br />

Available for the following SIMATIC HMI systems:<br />

- Mobile Panel 177 PN, Mobile Panel 277<br />

- TP 177B PN/DP, OP 177B PN/DP<br />

- TP 270, TP 277, OP 270, OP 277<br />

- MP 177, MP 270B, MP 277, MP 370, MP 377<br />

- WinCC flexible Runtime<br />

Communication between HMI systems is established on the<br />

basis of Ethernet networks, or via the Intranet/Internet:<br />

- Read and write access to variables;<br />

WinCC flexible Runtime or SIMATIC Panels make data<br />

(variables) available to other SIMATIC HMI systems or Office<br />

applications.<br />

- A SIMATIC HMI system can be used to control or monitor<br />

another system remotely;<br />

entry level for client/server configurations for distributed<br />

operator stations or for solutions with headend or control<br />

room.<br />

Local operation, visualization and data processing is as<br />

possible as plant-wide access to information or central<br />

archiving of process data. Integrated information flows ensure<br />

an overview of the status of all processes.<br />

Licensing:<br />

The license "WinCC flexible /Sm@rtAccess for Panel" or<br />

"WinCC flexible /Sm@rtAccess for WinCC flexible Runtime"<br />

must be installed on both the server and client operator panel.<br />

Server applications are the options Sm@rtServer, HTTP-Server<br />

and SOAP-Server. Client applications are the screen object<br />

Sm@rtClient display, and the utilization of the communication<br />

driver SIMATIC HTTP protocol.<br />

No license is required on the client system for access to a<br />

Sm@rtServer using the application Sm@rtClient.EXE or the<br />

Microsoft Internet Explorer. A license is also not required for<br />

the engineering system for configuring the runtime option<br />

4/60<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Flexible solution for location-independent access to HMI<br />

systems and process data<br />

Reduction in load on fieldbuses:<br />

WinCC flexible Runtime as well as SIMATIC Panels permit a<br />

control system, for example, to access the process data. The<br />

sensitive field level is not loaded by the control level as far as<br />

the communications requirements are concerned. The<br />

requirements are processed by WinCC flexible Runtime and<br />

the SIMATIC Panels.<br />

Simple, fast configuration of communications relationships<br />

using the WinCC flexible engineering software<br />

■ Application<br />

Use of machine-level HMI systems as data servers for<br />

higher-level automation components such as control systems<br />

or office systems. Process values from different machines, for<br />

example, are displayed on a process screen.<br />

Operator control and monitoring of machines covering large<br />

areas with several operator stations by one operator<br />

Operator control and monitoring of machine-level HMI<br />

systems from one central station (e.g. head-end station of a<br />

production line or from a control room)


■ Application (continued)<br />

Industrial Ethernet<br />

HMI Software<br />

SIMATIC WinCC flexible options<br />

Server 1 Server 2 Server 3 Server 4<br />

HTTP-Data<br />

Server/Client<br />

PROFIBUS<br />

Communication between HMI systems via Industrial Ethernet: Use of machine-level HMI systems as data servers for<br />

higher-level automation components<br />

Master Station<br />

Industrial Ethernet<br />

HTTP-Data<br />

Server/Client<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HTTP-Data<br />

Server/Client<br />

Sm@rtServer Sm@rtClient<br />

Application of the Sm@rtClient concept: Coordinated operation of several operator stations<br />

WinCC flexible /Sm@rtAccess<br />

Master Control Station<br />

HTTP Data Client<br />

SIMATIC HMI HTTP Protocol<br />

HTTP-Data<br />

Server/Client<br />

Operator Station 1 Operator Station 2 Operator Station n<br />

...<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00070<br />

G_<strong>ST</strong><strong>80</strong>_XX_00071<br />

4/61<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC flexible options<br />

WinCC flexible /Sm@rtAccess<br />

■ Application (continued)<br />

Use of the Sm@rtClient display: Operator control and monitoring of machine-level HMI systems from one central station<br />

■ Function<br />

Communication between different SIMATIC HMI systems or<br />

between the units of a machine or plant is carried out via<br />

Industrial Ethernet or intranet/Internet on the basis of<br />

Sm@rtAccess<br />

Possible communication relationships:<br />

Reading and writing the variables of a SIMATIC HMI system<br />

on the basis of an HTTP protocol<br />

- Reading and writing the variables of different HMI systems<br />

- Simple configuring of variables in the HMI client<br />

configuration using browsers in the WinCC flexible<br />

engineering tool<br />

- Reading and writing the variables of an HMI system using<br />

standard applications such as MS Excel. Communication is<br />

made possible by embedding a script in the application, on<br />

the basis of the SOAP protocol (Simple Object Access<br />

Protocol) superimposed by HTTP<br />

4/62<br />

Industrial Ethernet<br />

Server 1 Server 2 Server 3 Server 4<br />

PROFIBUS<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Master Control Station Sm@rtClient display<br />

Sm@rtServer Sm@rtServer Sm@rtServer Sm@rtServer<br />

Remote control of an operator station;<br />

The HMI application and communication with the PLC is<br />

carried out via the master station. In the case of spatially<br />

distributed machines/plants, which require a larger number of<br />

operator panels, so-called Sm@rtClients can be activated<br />

from here which are then assigned access to the master<br />

station and thus to the process. Access procedures guarantee<br />

that only one operator system can actively access the process<br />

at a time.<br />

- A configurable graphic object (Sm@rtClient display)<br />

embedded in process displays represents the screen of the<br />

associated HMI system (Sm@rtServers)<br />

- Powerful standard functions permit convenient and flexible<br />

operation of the display<br />

Password protection can be optionally activated for access to<br />

variables or for remote operation of an HMI system.<br />

G_<strong>ST</strong><strong>80</strong>_XX_00072


■ Technical specifications<br />

Type WinCC flexible /Sm@rtAccess<br />

The specifications are maximum<br />

values<br />

Execution platform<br />

SIMATIC Panels Mobile Panel 177 PN, Mobile<br />

Panel 277, TP/OP 177B PN/DP,<br />

TP/OP 270, TP/OP 277<br />

SIMATIC Multi Panels MP 177, MP 270B, MP 277,<br />

MP 370, MP 377<br />

<strong>PC</strong>s WinCC flexible Runtime<br />

Sm@rtAccess<br />

SIMATIC HMI HTTP protocol<br />

Number of connections for one<br />

client<br />

Mobile Panel 177 PN, TP/OP 177 B 4<br />

PN/DP, MP 177 as HTTP server<br />

Mobile Panel 277, TP/OP 270, TP/ 8<br />

OP 277, MP 270B, MP 277,<br />

MP 370, MP 377 as HTTP server<br />

for WinCC flexible Runtime 16<br />

Sm@rtAccess<br />

Sm@rtClient concept<br />

Number of Sm@rtClients that can<br />

connect to a Sm@rtServer at the<br />

same time1) 2)<br />

Mobile Panel 177 PN, TP/OP 177B 2 clients<br />

PN/DP, MP 177 as Sm@rtServer<br />

Mobile Panel 277, TP/OP 270, TP/ 3 clients for 6" devices<br />

OP 277, MP 270B, MP 277 as 2 clients for 8" and 10" devices<br />

Sm@rtServer<br />

MP 370, MP 377 as Sm@rtServer 3 clients for 12" devices<br />

2 clients for 15" devices<br />

1 client for 19" devices<br />

for WinCC flexible Runtime as 5 clients<br />

Sm@rtServer<br />

Number of Sm@rtClient displays<br />

per screen<br />

for Panels/Multi Panels 1<br />

for WinCC flexible Runtime 2<br />

1) Including 1 Service Client<br />

2) The Sm@rtServer and the WinCC flexible /Pro Agent option cannot be<br />

used simultaneously on OP/TP/MP 270/370. Parallel operation of the<br />

runtime options ProAgent, Sm@rtAccess and Sm@rtService is<br />

possible in the context of the MP 277 8" and 10" devices,<br />

Mobile Panel 277 as well as the MP 377. Limitation: a maximum of<br />

2 clients can be connected simultaneously to a Sm@rtServer.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SIMATIC WinCC flexible options<br />

WinCC flexible /Sm@rtAccess<br />

■ Ordering data Order No.<br />

WinCC flexible /Sm@rtAccess<br />

for SIMATIC Panel 1)<br />

Single license, license key only<br />

D 6AV6 618-7AB01-3AB0<br />

WinCC flexible /Sm@rtAccess<br />

for WinCC flexible 2008<br />

Runtime 1)<br />

B 6AV6 618-7AD01-3AB0<br />

Single license, license key only<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

1) The license must be installed on the server and on the client operator<br />

panel.<br />

Server applications are the options Sm@rtServer, HTTP-Server and<br />

SOAP-Server.<br />

Client applications are the screen object Sm@rtClient display, and the<br />

utilization of the communication driver HTTP protocol.<br />

A license is not required for the engineering system for configuration<br />

the runtime option.<br />

■ More information<br />

Note:<br />

Do you need a specific modification or option for the products<br />

described here? Then look up "Customized products", where<br />

you will find information about the Open Platform Program<br />

for the creation of user-specific functions and controls for<br />

WinCC flexible.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/63<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC flexible options<br />

WinCC flexible /Sm@rtService<br />

■ Overview<br />

Option for SIMATIC WinCC flexible Runtime and SIMATIC<br />

Panels for remote maintenance and servicing of machines/<br />

plant via the Internet/Intranet<br />

Available for the following SIMATIC HMI systems:<br />

- Mobile Panel 177 PN, Mobile Panel 277<br />

- TP 177B PN/DP, OP 177B PN/DP<br />

- TP 270, TP 277, OP 270, OP 277<br />

- MP 177, MP 270B, MP 277, MP 370, MP 377<br />

- WinCC flexible Runtime<br />

Licensing<br />

The "WinCC flexible /Sm@rtService for Panel" license or<br />

"WinCC flexible /Sm@rtService for WinCC flexible Runtime"<br />

license must be installed on the operator panels that use one<br />

of the following options/functions: Sm@rtServer, HTML pages<br />

(mini-web server), email.<br />

The remote service <strong>PC</strong> and engineering system do not require<br />

a license for configuration the runtime option.<br />

■ Benefits<br />

Fast elimination of faults or downtimes and thus increased<br />

productivity by means of global access to machines/systems<br />

by the service and maintenance personnel<br />

Avoids the need for site visits<br />

■ Application<br />

Remote maintenance and servicing of machines and plants<br />

via Internet/Intranet<br />

Calling of system information, control of target systems, and<br />

updating of data sets via Internet/Intranet<br />

Automatic sending of emails to experts for fast elimination of<br />

faults<br />

4/64<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Function<br />

Remote operator control and monitoring of<br />

SIMATIC HMI systems using Industrial Ethernet<br />

and/or via the Intranet/Internet<br />

Microsoft Internet Explorer V6.0 SP1 or higher is sufficient for<br />

accessing an HMI system.<br />

Remote control of an operating station<br />

The HMI application and communication with the controller<br />

takes place via the HMI system. Using Sm@rtService, the HMI<br />

systems in the machines/systems can be serviced remotely. An<br />

access process ensures that only one operator (either locally at<br />

the machine or remotely via Internet Explorer) can actively<br />

access the process at one time.<br />

Integrated Web Server to process standard HTML pages<br />

The following functions can be accessed from the homepage:<br />

Starting and stopping the HMI runtime for maintenance<br />

Remote access to recipe data sets, passwords and<br />

information specific to the HMI system<br />

Access the HMI system files via a file explorer<br />

Download configuration data via the Intranet/Internet<br />

Supplement with own HTML pages<br />

Sending e-mails to maintenance personnel via SMTP server<br />

(Simple Mail Transfer Protocol)<br />

Events that trigger an e-mail:<br />

- Reporting of a message class<br />

- Configurable standard functions: Changing the value of a<br />

variable, pressing a function key, scripts, etc.<br />

Possible e-mail content<br />

- Subject<br />

- Message text with process variables<br />

- Date/Time<br />

The optional use of e-mail/SMS gateways enables access to<br />

standard networks (external service provider required)<br />

Standard functions make maintenance and service functionality<br />

easier. WinCC flexible allows you to quickly and easily configure<br />

maintenance and service functions.<br />

Password protection can be activated as an option for<br />

accessing the HMI system. Different passwords may be<br />

configured for different functions.


■ Function (continued)<br />

<br />

Remote operator control and monitoring of SIMATIC HMI systems using<br />

Industrial Ethernet and/or via the Intranet/Internet<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Remote operator control and monitoring of SIMATIC HMI systems using<br />

Industrial Ethernet and/or via the Intranet/Internet<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00073<br />

G_<strong>ST</strong><strong>80</strong>_XX_00074<br />

HMI Software<br />

SIMATIC WinCC flexible options<br />

Engineering Station<br />

<strong>PC</strong>/PG<br />

<br />

<br />

WinCC flexible /Sm@rtService<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Remote operator control and monitoring of SIMATIC HMI systems using<br />

Industrial Ethernet and/or via the Intranet/Internet<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Sending e-mails to maintenance personnel via SMTP server<br />

(Simple Mail Transfer Protocol)<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

<br />

<br />

<br />

4/65<br />

<br />

<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC flexible options<br />

WinCC flexible /Sm@rtService<br />

■ Technical specifications<br />

■ Ordering data Order No.<br />

Type<br />

Execution platform<br />

WinCC flexible /Sm@rtService<br />

SIMATIC Panels Mobile Panel 177 PN, Mobile<br />

SIMATIC Multi Panels<br />

Panel 277, TP 177B PN/DP,<br />

OP 177B PN/DP, TP/OP 270,<br />

TP/OP 277<br />

MP 177, MP 270B, MP 277,<br />

MP 370, MP 377<br />

<strong>PC</strong>s<br />

Sm@rtService<br />

SIMATIC WinCC flexible Runtime<br />

1)<br />

WinCC flexible /Sm@rtService<br />

for SIMATIC Panels<br />

Remote access via<br />

HTML pages<br />

Internet Explorer V6.0 SP1 and<br />

higher<br />

for Panels/Multi Panels HTML V1.1 (no support for<br />

ActiveX, Java, ASP)<br />

for WinCC flexible Runtime HTML V1.1<br />

Sending emails via SMTP server<br />

Subject, message texts with 250<br />

characters of text per email;<br />

date/time of message, message<br />

no.<br />

1)<br />

D 6AV6 618-7BB01-3AB0<br />

Single license, license key only<br />

WinCC flexible /Sm@rtService<br />

for WinCC flexible Runtime<br />

2008 1)<br />

Single license, license key only<br />

D 6AV6 618-7BD01-3AB0<br />

1) The Sm@rtServer and the WinCC flexible /ProAgent option cannot be<br />

used simultaneously on OP/TP/MP 270/370. Parallel operation of the<br />

runtime options ProAgent, Sm@rtAccess and Sm@rtService is<br />

possible in the context of the MP 277 8" and 10" devices,<br />

Mobile Panel 277 as well as the MP 377. Limitation: a maximum of<br />

2 clients can be connected with a Sm@rtServer.<br />

4/66<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

1) The "WinCC flexible /Sm@rtService for Panel" license or "WinCC<br />

flexible /Sm@rtService for WinCC flexible Runtime" license must be<br />

installed on the operator panels that use one of the following options:<br />

Sm@rtServer, HTML pages, email.<br />

The remote service <strong>PC</strong> and engineering system do not require a<br />

license for configuration the runtime option.<br />

■ More information<br />

Note:<br />

Do you need a specific modification or option for the products<br />

described here? Then look up "Customized products", where<br />

you will find information about the Open Platform Program<br />

for the creation of user-specific functions and controls for<br />

WinCC flexible.


■ Overview<br />

Option for SIMATIC WinCC flexible Runtime as well as<br />

Multi Panels for communication with applications from<br />

different vendors (e.g. MES, ERP, or applications in the office<br />

sector)<br />

Available for the following SIMATIC HMI systems:<br />

- Mobile Panel 277, MP 270B, MP 277, MP 370, MP 377<br />

(use of O<strong>PC</strong> on XML basis)<br />

- WinCC flexible Runtime (use of O<strong>PC</strong> based on DCOM)<br />

One license is required for each operator station<br />

■ Benefits<br />

Higher level visualization system<br />

Industrial Ethernet<br />

On-site visualization<br />

PROFIBUS<br />

SIMATIC<br />

S7-300<br />

O<strong>PC</strong> Server<br />

Incorporation of automation components from different<br />

vendors into an automation concept<br />

Saving of development costs through communication<br />

between automation systems based on a homogeneous,<br />

uniform protocol<br />

Reduction in load on fieldbuses:<br />

WinCC flexible Runtime as well as SIMATIC Panels permit a<br />

control system, for example, to access the process data. The<br />

sensitive field level is not loaded by the control level as far as<br />

the communications requirements are concerned. The<br />

requirements are processed by WinCC flexible Runtime and<br />

the SIMATIC Panels.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

O<strong>PC</strong> Client<br />

SIMATIC<br />

S7-400<br />

■ Application<br />

HMI Software<br />

SIMATIC WinCC flexible options<br />

O<strong>PC</strong> Server<br />

O<strong>PC</strong> Client<br />

3rd party<br />

O<strong>PC</strong> Server<br />

3rd party<br />

PLCs<br />

WinCC flexible /O<strong>PC</strong> server<br />

O<strong>PC</strong> Server<br />

Multi Panel<br />

O<strong>PC</strong> (OLE for Process Control) is a standardized, open, uniform<br />

and multi-vendor software interface. O<strong>PC</strong> is based on the<br />

Windows technology of COM (Component Object Model),<br />

DCOM (Distributed COM) or on XML.<br />

Windows-based systems such as SIMATIC Panel <strong>PC</strong> or<br />

SIMATIC Multi Panels are used for tasks at the machine and<br />

process levels, and can communicate with all O<strong>PC</strong>-compatible<br />

applications via Ethernet using TCP/IP and O<strong>PC</strong>. WinCC flexible<br />

Runtime or the SIMATIC Multi Panel (O<strong>PC</strong> server) provide data<br />

for one or more O<strong>PC</strong> clients. As a result, local visualization and<br />

data processing are possible to the same extent as plant-wide<br />

calling of information or archiving of process data. Uniform flows<br />

of information guarantee an overview of the status of all<br />

processes.<br />

Communication with O<strong>PC</strong>-compatible applications from different<br />

vendors (e.g. MES, ERP, or applications in the office sector) is<br />

possible.<br />

O<strong>PC</strong> Foundation<br />

www.opcfoundation.org<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00078<br />

4/67<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC flexible options<br />

WinCC flexible /O<strong>PC</strong> server<br />

■ Function<br />

Use of a visualization system as a data server (O<strong>PC</strong> server) for<br />

higher-level automation components such as control systems<br />

or office systems<br />

- O<strong>PC</strong>-XML server for multi panels<br />

- O<strong>PC</strong> server (DCOM) for WinCC flexible Runtime<br />

The WinCC flexible engineering system can conveniently<br />

select a desired O<strong>PC</strong> item from the variables function<br />

of the O<strong>PC</strong> server using an O<strong>PC</strong> browser (component of the<br />

O<strong>PC</strong> server). To do this, the O<strong>PC</strong> server must be started and<br />

must be accessible for the engineering system.<br />

1) Data access via XML has a functional scope that is similar to<br />

O<strong>PC</strong> Data Access. A software adapter is required that must be<br />

installed on the O<strong>PC</strong> client <strong>PC</strong> to enable DCOM-based O<strong>PC</strong> clients to<br />

access the O<strong>PC</strong> XML server without any modification. The software<br />

adapter is supplied with WinCC flexible Engineering and Runtime.<br />

4/68<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Ordering data Order No.<br />

WinCC flexible /O<strong>PC</strong> Server for<br />

SIMATIC Multi Panels 1)<br />

D 6AV6 618-7CC01-3AB0<br />

Single license, license key only<br />

WinCC flexible /O<strong>PC</strong> Server for D 6AV6 618-7CD01-3AB0<br />

WinCC flexible Runtime 2008 1)<br />

Single license, license key only<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

1) A license is required for each operator station.<br />

The engineering system does not require a license for configuration<br />

the runtime option.<br />

■ Technical specifications<br />

Type WinCC flexible /O<strong>PC</strong> Server ■ More information<br />

Execution platform<br />

SIMATIC Panels<br />

SIMATIC Multi Panels<br />

<strong>PC</strong>s<br />

O<strong>PC</strong> server<br />

The specifications are maximum<br />

values<br />

Mobile Panel 277<br />

MP 270B, MP 277, MP 370,<br />

MP 377<br />

SIMATIC WinCC flexible Runtime<br />

Note:<br />

Do you need a specific modification or option for the products<br />

described here? Then look up "Customized products", where<br />

you will find information about the Open Platform Program<br />

for the creation of user-specific functions and controls for<br />

WinCC flexible.<br />

XML server for Multi Panels Supports the O<strong>PC</strong> XML Data<br />

Access specification V1.0 1)<br />

DCOM server for WinCC flexible Supports the O<strong>PC</strong> Data Access<br />

Runtime<br />

specification V1.0a and V2.0<br />

Number of connections that an<br />

O<strong>PC</strong> server can accommodate<br />

8


■ Overview<br />

<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00367<br />

HMI Software<br />

SIMATIC WinCC flexible options<br />

WinCC flexible /ProAgent<br />

■ Ordering data<br />

WinCC flexible /ProAgent<br />

Software option package for<br />

process diagnostics based on<br />

Functional enhancement for<br />

SIMATIC WinCC flexible;<br />

electronic documentation in<br />

English, French, German, Italian,<br />

and Spanish<br />

Order No.<br />

WinCC flexible /ProAgent for<br />

SIMATIC Panels 1)<br />

Runtime license (Single<br />

License) executable on Mobile<br />

Panel 277, TP/OP/MP 270/277<br />

and MP 370/377<br />

D 6AV6 618-7DB01-3AB0<br />

WinCC flexible /ProAgent for<br />

WinCC flexible Runtime 2008 1)<br />

Runtime license<br />

(Single License)<br />

D 6AV6 618-7DD01-3AB0<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

1) One license is required for each operator console. For the engineering<br />

system, no license is required for configuring the runtime option.<br />

Targeted and rapid process diagnostics in plants and ■ More information<br />

machines for SIMATIC S7 and SIMATIC HMI<br />

Note:<br />

Standardized diagnostics concept for various SIMATIC<br />

components<br />

Do you need a specific modification or option for the products<br />

described here? Then look up "Customized products", where<br />

No further configuration overhead for diagnostics functionality you will find information about the Open Platform Program<br />

Frees up PLC capacity with regard to memory and program<br />

execution time<br />

Note:<br />

For further information, refer to "SIMATIC ProAgent Process<br />

Diagnostics Software".<br />

for the creation of user-specific functions and controls for<br />

WinCC flexible.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/69<br />

4


4<br />

HMI Software<br />

SCADA system SIMATIC WinCC<br />

SIMATIC WinCC<br />

■ Overview<br />

<strong>PC</strong>-based operator control and monitoring system for<br />

visualizing and operating processes, production flows,<br />

machines and plants in all sectors – from the simple singleuser<br />

station through to distributed multi-user systems with<br />

redundant servers and cross-location solutions with Web<br />

clients. WinCC is the information hub for corporation-wide<br />

vertical integration.<br />

The basic system configuration (WinCC basic software)<br />

includes industry-standard functions for signaling and<br />

acknowledging events, archiving of messages and measured<br />

values, logging of all process and configuration data, user<br />

administration and visualization.<br />

The WinCC basic software forms the core of a wide range of<br />

different applications. Based on the open programming<br />

interfaces, a wide range of WinCC options (from <strong>Siemens</strong><br />

Industry Automation) and WinCC add-ons have been<br />

developed (by <strong>Siemens</strong>-internal and external partners).<br />

WinCC can be operated with every <strong>PC</strong> that meets the given<br />

HW requirements. Particularly, the SIMATIC Panel <strong>PC</strong> and<br />

SIMATIC Rack <strong>PC</strong> product range is available for the industrial<br />

use of WinCC systems. SIMATIC <strong>PC</strong>s impress with their<br />

powerful <strong>PC</strong> technology, are designed for round-the-clock<br />

operation, and can be operated in both office areas and harsh<br />

industrial environments.<br />

SIMATIC WinCC can be ordered in connection with<br />

SIMATIC I<strong>PC</strong> (Box / Rack / Panel <strong>PC</strong>) as SIMATIC HMI<br />

packages at favorable prices.<br />

Together with the Panel <strong>PC</strong> 477B, there are turnkey solutions<br />

as WinCC Standard Client and with the SIMATIC HMI I<strong>PC</strong>477C<br />

as WinCC Standard Client or Single Station. (See also<br />

Packages and HMI I<strong>PC</strong>477C)<br />

Current versions:<br />

SIMATIC WinCC V7.0 SP2:<br />

Executable with<br />

- Windows 7 (32-bit) Professional, Enterprise, Ultimate<br />

- Windows XP Professional SP3<br />

- Windows 2003 Server SP2 and<br />

Windows 2003 Server R2 SP2<br />

- Windows 2008 Server SP2 (32-bit)<br />

contains the Microsoft SQL Server 2005 SP2<br />

- Use in virtual environments – for further information, see<br />

http://support.automation.siemens.com/WW/view/en/<br />

49370459<br />

SIMATIC WinCC V6.2 SP3:<br />

Executable with<br />

- Windows XP Professional<br />

- Windows 2000 Professional<br />

- Windows Server 2003 and Windows Server 2003 R2<br />

Contains the Microsoft SQL Server 2005 SP2<br />

4/70<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

All-purpose<br />

- Solutions for all sectors<br />

- Multilingual for worldwide usage<br />

- Can be integrated into all automation solutions<br />

All OCM functions on board<br />

- User administration<br />

- Operator control and monitoring<br />

- Reporting, acknowledging, and archiving of events<br />

- Acquisition, compression and archiving of measured values<br />

(incl. long-term backup)<br />

- Logging and documenting of process and configuration<br />

data<br />

Can be configured simply and efficiently<br />

- Configuration wizards let the user focus on the essentials<br />

- In the picture by means of cross-reference lists and screen<br />

property displays<br />

- Configuration of multilingual applications<br />

- Configuring tool for configuring bulk data<br />

Universally scalable<br />

- Expandable from single station to client-server<br />

configurations<br />

- Increased availability by means of redundant servers<br />

- Process visualization via the web with the WinCC<br />

WebNavigator<br />

Open standards for simple integration<br />

- Efficient real-time database MS SQL Server 2005<br />

- Open for application modules with ActiveX controls<br />

- Visual Basic for Applications for individual expansions<br />

- O<strong>PC</strong> for cross-vendor communication<br />

Process visualization with Plant Intelligence<br />

- Integrated high-performance Historian on the basis of the<br />

Microsoft SQL Server 2005<br />

- Integrated evaluation functions for the online analysis<br />

(statistical process control)<br />

- Production optimization with the help of diverse options<br />

Expandable using options and add-ons<br />

- Options for scalable configurations<br />

- Options for increasing the availability<br />

- Options for IT & business integration<br />

- Options for SCADA expansions<br />

- Options for validation in accordance<br />

with FDA 21 CFR Part 11<br />

- Options for the use of telecontrol protocols<br />

Part of Totally Integrated Automation<br />

- Direct access to the tag and message configuration of the<br />

SIMATIC control system<br />

- Integrated diagnostic functions for increasing productivity<br />

- Options for the use of telecontrol protocols


■ Benefits (continued)<br />

Innovations of V7.0<br />

Innovated runtime user interface<br />

- New graphical options such as transparency, color<br />

gradients, shades, and much more<br />

- Central management of switching between graphic designs<br />

- Central management of switching between color palettes<br />

- New graphical objects: combo boxes, list boxes, text fields<br />

with multiple lines, multimedia control and much more<br />

New, revised runtime controls<br />

- An unlimited number of alarms can be displayed in Alarm<br />

Control<br />

- User-specific filter options in Alarm Control<br />

- Identical, expanded layout for messages, trend curves,<br />

tables and UserArchive Control<br />

New, centrally modifiable graphic objects/faceplates<br />

- New, easy to configure faceplates with the option of<br />

centralized modification.<br />

- Can be used and configured on a cross-project basis in the<br />

Graphics Designer<br />

Additional configuration options<br />

- Can run as service and is thus suitable for use in existing<br />

IT server environments.<br />

- The standard client without Microsoft SQL Server installation<br />

reduces installation costs and hardware requirements<br />

- Revised and simplified WinCC setup with one-click<br />

installation option<br />

Improved support for multi-language projects<br />

- New, central editor for importing and exporting all WinCC<br />

texts<br />

- New filter mechanisms in the text library for simplified<br />

management of texts<br />

SIMATIC Logon centralized user administration (included in<br />

the scope of supply)<br />

... and more<br />

■ Application<br />

SIMATIC WinCC is designed for visualization and operation of<br />

processes, manufacturing cycles, machines and plants. With its<br />

powerful process interface, especially to the SIMATIC family,<br />

and the secure data archiving, WinCC enables highly available<br />

solutions for the process control.<br />

The sector-neutral basic system enables universal usage in all<br />

automation applications. Sector-specific solutions can, for<br />

example, be implemented using WinCC options (e.g. FDA<br />

options for the pharmaceutical industry) and sector-specific<br />

add-ons (e.g. for the water industry).<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Design<br />

HMI Software<br />

SCADA system SIMATIC WinCC<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC WinCC<br />

SIMATIC WinCC is available as a complete package and as a<br />

runtime package with 128, 512, 2048, 8192, 65536, 102400,<br />

153600, 262144 PowerTags 1) . PowerTags are data points that<br />

are connected to controllers or other data sources over a WinCC<br />

channel. Up to 32 alarms can be obtained from one data point.<br />

Moreover, internal tags without coupling are available for<br />

additional system performance. In addition WinCC also contains<br />

512 archive tags. Individual archive licenses can be obtained for<br />

greater quantity structures.<br />

Licenses for a multi-user configuration<br />

The system software with the required number of PowerTags and<br />

additionally the option WinCC/server must be installed on the<br />

server. In the basic configuration, an RT128 or RT client license<br />

is sufficient for the clients. In order to configure on clients, an<br />

RC128 or RC client license is required.<br />

1) V6: 128, 256, 1024, 8192, 65536 Power Tags<br />

■ Function<br />

The powerful configuration functions of SIMATIC WinCC<br />

contribute to a reduced engineering and training overhead and<br />

lead to a more flexible use of personnel and greater operational<br />

reliability. Whoever is familiar with Microsoft Windows can also<br />

operate the WinCC Explorer, the central switching point of<br />

WinCC.<br />

In combination with other SIMATIC components, the system is<br />

also equipped with auxiliary functions such as process<br />

diagnostics and maintenance. All SIMATIC engineering tools<br />

work together in the configuration of the functions.<br />

SIMATIC WinCC offers a complete basic functionality for<br />

process visualization and operation. To this end, WinCC has a<br />

number of editors and interfaces that can be used to individually<br />

configure this functionality according to the respective application.<br />

Expansions of a WinCC station for control tasks are also<br />

possible with minimal engineering effort.<br />

4/71<br />

4


4<br />

HMI Software<br />

SCADA system SIMATIC WinCC<br />

SIMATIC WinCC<br />

■ Function (continued)<br />

WinCC editors Task or configurable runtime<br />

functionality<br />

WinCC Explorer Central project management for the<br />

quick access to all project data and<br />

central settings<br />

WinCC Graphics Designer Graphics system for user-defined visualization<br />

and operation via pixel-graphic<br />

objects<br />

WinCC Alarm Logging Signaling system for detecting and<br />

archiving events with display and<br />

control options according to DIN 19235;<br />

freely selectable message classes,<br />

message display and logging<br />

WinCC Tag Logging Process archiving for the acquisition,<br />

compression and storage of measured<br />

values, e.g., presentation in trend and<br />

table format as well as further<br />

processing<br />

WinCC Report Designer Reporting and logging system for time<br />

and event-controlled documentation of<br />

messages, operator inputs and current<br />

process data in the form of user reports<br />

or project documentation in an arbitrary<br />

layout<br />

WinCC User Administrator Tool for user-friendly administration of<br />

users and authorizations<br />

WinCC Global Script Processing functions with limitless<br />

functionality by means of the use of<br />

VBScript and ANSI-C<br />

Interfaces<br />

Task or configurable runtime<br />

functionality<br />

Communication channels For communication with subordinate<br />

controls (SIMATIC protocols,<br />

PROFIBUS DP, PROFIBUS FMS, DDE<br />

and O<strong>PC</strong> server included in the scope of<br />

delivery)<br />

Standard interfaces For the open integration of other<br />

Windows applications via WinCC,<br />

WinCC-OLE-DB, ActiveX, OLE, DDE,<br />

O<strong>PC</strong>, etc.)<br />

Programming ports For the individual access to data and<br />

functions of WinCC and for the<br />

integration in user programs with<br />

VBA, VB Script, C-API (ODK), C-Script<br />

(ANSI-C)<br />

4/72<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Integration<br />

Integration in company-wide solutions<br />

(IT and business integration)<br />

WinCC is strictly based on Microsoft technology, which provides<br />

for the greatest possible compatibility and integration ability.<br />

ActiveX and .net 1) controls support technology and sectorspecific<br />

expansions. Cross-manufacturer communication is also<br />

a simply exercise. The reason: WinCC can be used as an<br />

O<strong>PC</strong> client and server, and in addition to access to current<br />

process values, it also supports standards such as O<strong>PC</strong> HDA<br />

(Historical Data Access), O<strong>PC</strong> Alarm & Events, and O<strong>PC</strong> XML<br />

Data Access. Just as important: Visual Basic for Applications<br />

(VBA) for user-specific expansions of the WinCC Graphics<br />

Designer and Visual Basic Scripting (VBS) as an easy-to-learn,<br />

open runtime language. If desired, professional application<br />

developers can also use ANSI-C. And the access to the<br />

API programming interfaces is really simple with the<br />

Open-Development-Kit ODK.<br />

WinCC integrates a powerful and scalable Historian function<br />

based on the Microsoft SQL Server 2005 in the basic system.<br />

Thus, the user is given all possibilities: from high-performance<br />

archiving of current process data, to long-term archiving with<br />

high data compression, through to a central information<br />

turntable in form of a company-wide Process Historian. With the<br />

help of the option Central Archive Server, this can be created<br />

within the framework of a WinCC solution. Versatile clients and<br />

tools for evaluation, the open interfaces, special options<br />

(Connectivity Pack, Connectivity Station, IndustrialDataBridge)<br />

provide the basis for an effective IT and business integration.<br />

1) Only supported by WinCC V7.0<br />

Integration in automation solutions<br />

WinCC is an open process visualization system and offers the<br />

option of connecting the most diverse control systems.<br />

Released communication software<br />

Only communication software with the listed (or higher) product<br />

versions should be used. Corresponding SIMATIC NET<br />

upgrades are available for the upgrading of older versions.


WinCC supports the standards:<br />

O<strong>PC</strong> Data Access 2.05a<br />

O<strong>PC</strong> Data Access 3.00<br />

O<strong>PC</strong> XML Data Access 1.00 (Connectivity Pack/Connectivity<br />

Station)<br />

O<strong>PC</strong> HDA 1.20 (Connectivity Pack/Connectivity Station)<br />

O<strong>PC</strong> A&E 1.10 (Connectivity Pack/Connectivity Station)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SCADA system SIMATIC WinCC<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC WinCC<br />

■ Integration (continued)<br />

Number of connectable controls<br />

Coupling overview<br />

For the number of the connectable controls via Industrial<br />

Protocol Description<br />

Ethernet CP 1613, the following applies for a message frame<br />

length of 512 bytes:<br />

SIMATIC S7<br />

SIMATIC S7 Protocol Suite Channel DLL for S7 functions via MPI,<br />

PROFIBUS or Ethernet Layer 4 + TCP/IP<br />

Type of coupling Number of nodes<br />

SIMATIC S5<br />

SIMATIC S5 Ethernet Layer up to 60<br />

SIMATIC S5 Ethernet Channel DLL for S5 Layer 4 communi-<br />

4 + TCP/IP<br />

Layer 4<br />

cation + TCP/IP<br />

SIMATIC S7 Protocol Suite up to 64<br />

SIMATIC S5 Programmer Channel DLL and driver for serial<br />

SIMATIC 505 Ethernet Layer<br />

4 + TCP/IP<br />

up to 60<br />

Port AS511<br />

communication with S5 via AS511<br />

protocol to programmers port<br />

Via PROFIBUS, a maximum of 8 controls with CP 5611 and a<br />

maximum of 44 controls with CP 5613 can be connected. With<br />

SIMATIC S5 Serial 3964R Channel DLL and driver for serial<br />

communication with S5 via RK512<br />

protocol<br />

approx. 10 or more controls, the usage of Industrial Ethernet is<br />

recommended.<br />

Mixed mode with different controls<br />

SIMATIC S5 PROFIBUS-FDL<br />

SIMATIC 505<br />

SIMATIC 505 Serial<br />

Channel DLL for S5-FDL<br />

Channel DLL and driver for serial<br />

With their multi-protocol stack, the communications processors<br />

communication with 505 via NITP/TBP<br />

CP 1613 and CP 5613 allow for the parallel operation of two<br />

protocols, e.g. for the mixed operation of different controls via a<br />

protocol to SIMATIC 535/545/555/565/<br />

575<br />

bus cable. WinCC supports the operation of two similar interface SIMATIC 505 Ethernet Channel DLL for 505 Layer 4<br />

boards only in connection with the channels SIMATIC S5<br />

Layer 4<br />

communication<br />

Ethernet Layer 4 (2 x CP 1613), SIMATIC S7 Protocol Suite<br />

(2 x CP 1613, 2 x CP 5613) as well as PROFIBUS DP<br />

(4 x CP 5613; each CP 5613 max. 122 slaves). In addition to<br />

communication over industrial Ethernet CP 1613 or PROFIBUS<br />

SIMATIC 505 TCP/IP Channel DLL for 505 TCP/IP<br />

communication<br />

Non-<strong>Siemens</strong> controllers (from WinCC V7.0)<br />

CP 5613, one CP 5611 can be used in each case for communi- Allen Bradley<br />

Channel DLL and drivers for communication<br />

with SIMATIC S7 via MPI.<br />

Ethernet IP<br />

cation with Allen Bradley controllers via<br />

Ethernet TCP/IP with Ethernet IP protocol<br />

Client-server communication<br />

Modbus TCP/IP Channel DLL and drivers for communi-<br />

The communication between the clients and the server is<br />

cation with Modicon controllers via<br />

achieved using the TCP/IP protocol. The construction of a<br />

separate <strong>PC</strong>-LAN is recommended. For small projects with<br />

Ethernet TCP/IP using Modbus TCP/IP<br />

protocol<br />

correspondingly small message frame advent, a SIMATIC NET Mitsubishi MC TCP/IP Channel DLL and drivers for communi-<br />

Industrial Ethernet can be used for both process communication<br />

cation with Mitsubishi controllers via<br />

(WinCC/Server ↔ PLC) and for the <strong>PC</strong>-<strong>PC</strong> communication<br />

(WinCC/client ↔ WinCC/server).<br />

Ethernet TCP/IP using Mitsubishi MC<br />

TCP/IP protocol<br />

Channel-DLL PROFIBUS DP<br />

In accordance with the PROFIBUS standard, DP/slaves are<br />

always permanently assigned to a DP master; i.e. a second<br />

WinCC station (DP/master) cannot access the same controls<br />

(DP/slave). This means that a redundant operation of two WinCC<br />

stations is not possible with the use of the PROFIBUS DP<br />

coupling.<br />

Cross-manufacturer<br />

O<strong>PC</strong> client<br />

Connection to controls from other manufacturers:<br />

For the connection of controls from other manufacturers, O<strong>PC</strong><br />

(OLE for Process Control) is recommended.<br />

Current notes and information about O<strong>PC</strong> servers from various<br />

suppliers can be found at: www.opcfoundation.org<br />

1) for<br />

DA, XML DA<br />

O<strong>PC</strong> server for<br />

DA, XML DA, A&E, HDA<br />

PROFIBUS FMS<br />

Channel DLL for O<strong>PC</strong> communication,<br />

WinCC can acquire data from O<strong>PC</strong><br />

server applications.<br />

Server applications for O<strong>PC</strong> communication;<br />

WinCC provides process data for<br />

O<strong>PC</strong> client<br />

Channel DLL for PROFIBUS FMS<br />

PROFIBUS DP Channel DLL for PROFIBUS DP<br />

1) Application note:<br />

The parallel usage of the O<strong>PC</strong> client channel allows, for example, the<br />

connection to an SNMP-O<strong>PC</strong> server for visualization of the data<br />

contained there. The SNMP-O<strong>PC</strong> server enables monitoring of any<br />

network components (e.g. switch) that support the protocol SNMP.<br />

You can find more information under SIMATIC NET Communications<br />

Systems/SNO<strong>PC</strong> Server.<br />

4/73<br />

4


4<br />

HMI Software<br />

SCADA system SIMATIC WinCC<br />

SIMATIC WinCC<br />

■ Integration (continued)<br />

Communications components for PG/<strong>PC</strong> for SIMATIC (for WinCC V7.0)<br />

Industrial Ethernet SIMATIC S5 SIMATIC S5 SIMATIC S7<br />

Ethernet TCP/IP Protocol<br />

Layer 4<br />

Suite<br />

System interface possible<br />

1) Via any Interface Board with NDIS 3.0 interface; no separate communications software required<br />

2) See ordering data for SIMATIC NET upgrade packages<br />

3) SIMATIC NET Version 8.0 SP1 scope of supply includes SIMATIC NET Edition 2008 SP2 (V7.1)<br />

4) SOFTNET-S7 Lean included in scope of supply of WinCC V7.0<br />

4/74<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC 505<br />

Ethernet<br />

Layer 4<br />

SIMATIC 505<br />

TCP/IP 1)<br />

Order No.<br />

WinCC – channel DLL<br />

SIMATIC S5 Ethernet Layer 4 • • Included in the basic<br />

Channel DLL for S5 Layer 4<br />

communication + TCP/IP<br />

package<br />

SIMATIC S7 Protocol Suite<br />

• Included in the basic<br />

Channel DLL for S7 functions<br />

package<br />

SIMATIC 505 Ethernet Layer 4<br />

• Included in the basic<br />

Channel DLL for 505 Layer 4<br />

communication<br />

package<br />

SIMATIC 505 TCP/IP 1)<br />

• Included in the basic<br />

Channel DLL for 505 TCP/IP<br />

communication<br />

Communication components for extension of the OS/OP<br />

package<br />

CP 1612<br />

<strong>PC</strong>I card for connecting a PG/<strong>PC</strong><br />

to Industrial Ethernet<br />

(SOFTNET-S7 or SOFTNET-S7<br />

Lean communications software<br />

must be ordered separately)<br />

• • 6GK1 161-2AA00<br />

SOFTNET-S7<br />

communications software for<br />

S7 functions (max. 64 connections)<br />

• •<br />

Version 8.0 SP1 2)3)<br />

for (32-bit) Windows 7<br />

• 6GK1 704-1CW<strong>80</strong>-3AA0<br />

Edition 2008 SP2 (V7.1) 2)<br />

for Windows XP/2003 Server/<br />

(32-bit) 2008 Server<br />

• 6GK1 704-1CW71-3AA0<br />

SOFTNET-S7 Lean<br />

communications software for S7<br />

functions (max. 8 connections)<br />

• •<br />

Version 8.0 SP1 2) 3) 4)<br />

for (32-bit) Windows 7<br />

• 6GK1 704-1LW<strong>80</strong>-3AA0<br />

Edition 2008 SP2 (V7.1) 2) 4)<br />

for Windows XP/2003 Server /<br />

(32-bit) 2008 Server<br />

• 6GK1 704-1LW71-3AA0<br />

CP 1613<br />

<strong>PC</strong>I card for connecting a PG/<strong>PC</strong><br />

to Industrial Ethernet (S7-1613<br />

communications software must<br />

be ordered separately)<br />

• • • • 6GK1 161-3AA00<br />

CP 1613 A2<br />

<strong>PC</strong>I card (32-bit) for connecting a<br />

PG/<strong>PC</strong> to Industrial Ethernet<br />

(S7-1613 communications<br />

software required)<br />

• • • • 6GK1 161-3AA01<br />

CP 1623<br />

<strong>PC</strong>I Express X1 card (32-bit) for<br />

connecting a PG/<strong>PC</strong> to Industrial<br />

Ethernet (S7-1613 communications<br />

software required)<br />

• • • • 6GK1 162-3AA00<br />

S7-1613<br />

communications software for<br />

S7 functions and S5/505 Layer 4<br />

communication with TCP/IP<br />

• • • •<br />

Version 8.0 SP1 2) 3)<br />

for (32-bit) Windows 7<br />

• 6GK1 716-1CB<strong>80</strong>-3AA0<br />

Edition 2008 SP2 (V7.1) 2)<br />

for Windows XP/2003 Server /<br />

(32-bit) 2008 Server<br />

• 6GK1 716-1CB71-3AA0


■ Integration (continued)<br />

Communications components for PG/<strong>PC</strong> for SIMATIC (for WinCC V7.0)<br />

PROFIBUS SIMATIC S5<br />

PROFIBUS FDL<br />

WinCC – channel DLL<br />

SIMATIC S5 PROFIBUS FDL<br />

Channel DLL for S5-FDL<br />

SIMATIC S7 Protocol Suite<br />

Channel DLL for S7 functions<br />

PROFIBUS DP<br />

Channel DLL for PROFIBUS DP<br />

PROFIBUS FMS<br />

Channel DLL for PROFIBUS FMS<br />

System interface possible<br />

1) See ordering data for SIMATIC NET upgrade package<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC S7<br />

Protocol Suite<br />

HMI Software<br />

SCADA system SIMATIC WinCC<br />

PROFIBUS DP PROFIBUS FMS Order No.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC WinCC<br />

• Included in the basic<br />

package<br />

• Included in the basic<br />

package<br />

• Included in the basic<br />

package<br />

• Included in the basic<br />

package<br />

Communication components for extension of the OS/OP<br />

CP 5611 A2<br />

<strong>PC</strong>I card (32-bit) for the connection of<br />

PG/<strong>PC</strong> to PROFIBUS or MPI (communications<br />

software included in the<br />

WinCC basic package)<br />

• 6GK1 561-1AA01<br />

CP 5621<br />

<strong>PC</strong>I Express X1 card (32-bit) for the<br />

connection of PG/<strong>PC</strong> to PROFIBUS or<br />

MPI<br />

(communications software included in<br />

WinCC basic package)<br />

• • 6GK1 562-1AA00<br />

CP 5512<br />

<strong>PC</strong>MCIA card (Cardbus 32-bit) for the<br />

connection of PG/<strong>PC</strong> to PROFIBUS or<br />

MPI (communications software<br />

included in WinCC basic package)<br />

• 6GK1 551-2AA00<br />

CP 5711<br />

USB adapter for connecting a PG/<strong>PC</strong><br />

to PROFIBUS or MPI (communications<br />

software included in the WinCC<br />

basic package)<br />

• • 6GK1 571-1AM00<br />

CP 5613 A2<br />

<strong>PC</strong>I card (32-bit) for connecting a <strong>PC</strong><br />

to PROFIBUS (S7-5613 communications<br />

software or DP-5613 or<br />

FMS-5613 required)<br />

• • • 6GK1 561-3AA01<br />

CP 5623<br />

<strong>PC</strong>I Express X1 card (32-bit) for<br />

connecting a PG/<strong>PC</strong> to PROFIBUS or<br />

MPI (S7-5613 communications<br />

software or DP-5613 or FMS-5613<br />

required)<br />

• • • • 6GK1 562-3AA00<br />

S7-5613 communications software for<br />

S7 functions + FDL<br />

• •<br />

Version 8.0 SP1 1) 2)<br />

for (32-bit) Windows 7<br />

• 6GK1 713-5CB<strong>80</strong>-<br />

3AA0<br />

Edition 2008 SP2 (V7.1) 1) 2)<br />

for Windows XP/2003 Server / (32-bit)<br />

2008 Server<br />

DP-5613<br />

communications software for<br />

DP master + FDL<br />

• 6GK1 713-5CB71-<br />

3AA0<br />

Version 8.0 SP1 1) 2)<br />

for (32-bit) Windows 7<br />

• 6GK1 713-5DB<strong>80</strong>-<br />

3AA0<br />

Edition 2008 SP2 (V7.1) 1) 2)<br />

for Windows XP/2003 Server / (32-bit)<br />

2008 Server<br />

FMS-5613<br />

communications software for<br />

PROFIBUS-FMS + FDL<br />

Version 8.0 SP1 1) 2)<br />

for (32-bit) Windows 7<br />

• 6GK1 713-5DB71-<br />

3AA0<br />

Edition 2008 SP2 (V7.1) 1) 2)<br />

for Windows XP/2003 Server / (32-bit)<br />

2008 Server<br />

• 6GK1 713-5FB71-<br />

3AA0<br />

2) SIMATIC NET Version 8.0 SP1 scope of supply includes SIMATIC NET<br />

Edition 2008 SP2 (V7.1)<br />

4/75<br />

4


4<br />

HMI Software<br />

SCADA system SIMATIC WinCC<br />

SIMATIC WinCC<br />

■ Communications examples<br />

WinCC single-user system: PROFIBUS with S7 communication<br />

WinCC single-user system: Industrial Ethernet with S7 communication<br />

4/76<br />

PROFIBUS<br />

Industrial Ethernet<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Standard <strong>PC</strong><br />

with WinCC<br />

e.g. RC 64 k or RT 64 k<br />

SIMATIC S7-400<br />

- CP 443-5 Extended<br />

(DP/M, S7, S/R)<br />

6GK7 443-5DX04-0XE0<br />

- CP 443-5 Basis (FMS, S7, S/R)<br />

6GK7 443-5FX02-0XE0<br />

- NCM S7 PROFIBUS manual<br />

(SIMATIC NET CD or<br />

Internet Download)<br />

Standard <strong>PC</strong><br />

with WinCC<br />

e.g. RC 64 k or RT 64 k<br />

- CP 443-1 (S7, S/R) ISO + TCP<br />

6GK7 443-1EX20-0XE0<br />

- CP 443-1 Advanced<br />

(S7, S/R, HTTP)<br />

6GK7 443-1GX20-0XE0<br />

- NCM S7 PROFIBUS manual<br />

(SIMATIC NET CD or<br />

Internet Download)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC NET PROFIBUS (S7 functions)<br />

- CP 5613 A2<br />

6GK1 561-3AA01<br />

- CP 5623<br />

6GK1 562-3AA00<br />

- S7-5613<br />

(communication software)<br />

6GK1 713-5CB<strong>80</strong>-3AA0<br />

SIMATIC S7-300<br />

- CP 342-5 (DP, S7, S/R)<br />

6GK7 342-5DA02-0XE0<br />

- CP 343-5 (FMS, S7, S/R)<br />

6GK7 343-5FA01-0XE0<br />

- NCM S7 PROFIBUS manual<br />

(SIMATIC NET CD or<br />

Internet Download)<br />

SIMATIC NET Industrial Ethernet (S7 functions)<br />

- CP 1613 A2<br />

6GK1 161-3AA01<br />

- CP 1623<br />

6GK1 162-3AA00<br />

- S7-1613<br />

(communication software)<br />

6GK1 716-1CB<strong>80</strong>-3AA0<br />

SIMATIC S7-400 SIMATIC S7-300<br />

- CP 343-1 (S7, S/R) ISO + TCP<br />

6GK7 343-1EX30-0XE0<br />

- CP 343-1 Advanced<br />

(S7, S/R, HTTP)<br />

6GK7 343-1GX30-0XE0<br />

- NCM S7 PROFIBUS manual<br />

(SIMATIC NET CD or<br />

Internet Download)<br />

G_<strong>ST</strong><strong>80</strong>_XX_00010<br />

G_<strong>ST</strong><strong>80</strong>_XX_00011


■ Communications examples (continued)<br />

PROFIBUS FMS<br />

SIMATIC S7-300<br />

- CP 343-5<br />

(FMS, S7, S/R)<br />

6GK7 343-5FA01-0XE0<br />

WinCC single-user system: PROFIBUS FMS<br />

Standard <strong>PC</strong><br />

with WinCC<br />

e.g. RC 64 k or RT 64 k<br />

WinCC multi-user system with operable server<br />

Standard <strong>PC</strong><br />

with WinCC<br />

e.g. RC 64 k or RT 64 k<br />

+ FMS channel DLL<br />

Server<br />

SIMATIC S7-400<br />

- CP 443-5 Basic<br />

(FMS, S7, S/R)<br />

6GK7 443-5FX02-0XE0<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

without<br />

operator controls:<br />

32 clients<br />

+ 3 web clients<br />

or<br />

50 web clients<br />

+ 1 client<br />

HMI Software<br />

SCADA system SIMATIC WinCC<br />

SIMATIC NET PROFIBUS-FMS<br />

- CP 5613 A2<br />

6GK1 561-3AA00<br />

- CP 5623<br />

6GK1 562-3AA00<br />

- FMS-5613<br />

(communication software)<br />

6GK1 713-5FB<strong>80</strong>-3AA0<br />

SIMATIC S5-<br />

115/135/155U<br />

- CP 5431 FMS/DP<br />

6GK1 543-1AA01<br />

- COM 5431 FMS/DP<br />

6GK1 745-1AD00-0EA0<br />

+ TCP/IP<br />

interface module<br />

Client Client<br />

SIMATIC S7-400 SIMATIC S7-300<br />

This allows you to set up the following application examples<br />

- WinCC single-user system: SIMATIC NET PROFIBUS with S7 functions<br />

- WinCC single-user system: SIMATIC NET Industrial Ethernet with S7 functions<br />

- WinCC single-user system: SIMATIC NET PROFIBUS-FMS<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC WinCC<br />

up to 4 clients<br />

with operator<br />

controls<br />

TERMINAL BUS TCP/IP<br />

PROCESS BUS (Industrial Ethernet/PROFIBUS)<br />

G_<strong>ST</strong><strong>80</strong>_XX_00012<br />

G_<strong>ST</strong><strong>80</strong>_XX_00013<br />

4/77<br />

4


4<br />

HMI Software<br />

SCADA system SIMATIC WinCC<br />

SIMATIC WinCC<br />

■ Communications examples (continued)<br />

- O<strong>PC</strong> Server<br />

functionality<br />

(O<strong>PC</strong> Server<br />

option for<br />

WinCC flexible<br />

required)<br />

- integrated<br />

PROFIBUS<br />

interface<br />

O<strong>PC</strong> coupling<br />

4/78<br />

Higher-level visualisation system<br />

Industrial Ethernet<br />

On-site visualization<br />

PROFIBUS<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

O<strong>PC</strong> Client<br />

O<strong>PC</strong> Server O<strong>PC</strong> Server<br />

SIMATIC S7-300<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

- O<strong>PC</strong> server functionality<br />

(included in WinCC basic package)<br />

- TCP-IP interface board required<br />

SIMATIC S7-400<br />

O<strong>PC</strong> Client<br />

O<strong>PC</strong> Server<br />

third-party<br />

PLCs<br />

- O<strong>PC</strong> Server<br />

functionality<br />

(included in WinCC<br />

basic package)<br />

- TCP-IP Interface<br />

board required<br />

- O<strong>PC</strong> Client<br />

functionality<br />

(included in WinCC<br />

basic package)<br />

- O<strong>PC</strong> Server<br />

required for<br />

interfacing with<br />

third-party PLCs<br />

G_<strong>ST</strong><strong>80</strong>_XX_00015


■ Technical specifications<br />

1) An AMD system with comparable performance can also be used<br />

2) Hardware requirements when using Microsoft XP Professional<br />

HMI Software<br />

SCADA system SIMATIC WinCC<br />

Type SIMATIC WinCC V7.0 SP2 SIMATIC WinCC V6.2 SP3<br />

Operating system Windows 7 (32-bit) Ultimate, Business and Enterprise<br />

Windows XP Professional SP2/SP3<br />

Windows 2003 Server SP2 and Windows 2003<br />

Server R2 SP2<br />

Windows 2008 Server SP2<br />

<strong>PC</strong> hardware requirements<br />

Processor type 1)<br />

Minimum Single-user station/server:<br />

Pentium 3, 1 GHz 2)<br />

Central Archive Server:<br />

Pentium 4, 2.5 GHz<br />

Client:<br />

Pentium 3, <strong>80</strong>0 MHz 2)<br />

WebClient/DataMonitor Client: Pentium III, 600 MHz<br />

2)<br />

Recommended Single-user station/server:<br />

Pentium 4, 2.5 GHz 2)<br />

Central Archive Server:<br />

Pentium 4 or Dual Core, 3 GHz<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Windows XP Professional SP3,<br />

Windows 2000 Professional SP4,<br />

Windows Server 2003 SP2,<br />

Windows Server 2003 R2 SP2<br />

Single-user station/server:<br />

Pentium III, 1 GHz<br />

Central Archive Server:<br />

Pentium 4, 2 GHz<br />

Client:<br />

Pentium III, 600 MHz<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC WinCC<br />

Single-user station/server: Pentium 4, 2 GHz<br />

Central Archive Server:<br />

Pentium 4, 2.5 GHz<br />

Client: Pentium 4, 2 GHz 2) Client: Pentium III, 1 GHz<br />

WebClient/DataMonitor Client: Pentium III, 1 GHz WebClient/DataMonitor Client: Pentium III, 1 GHz<br />

RAM<br />

Minimum Single-user station/server: 1 GB 2) Single-user station: 512 MB, server: 1 GB<br />

Central Archive Server: 2 GB Central Archive Server: 1 GB<br />

Client: 512 MB 2) Client: 512 MB<br />

WebClient/DataMonitor Client: 256 MB 2) WebClient/DataMonitor Client: 256 MB<br />

Recommended Single-user station/server: 2 GB 2) Single-user station: >= 1 GB,<br />

server: >1 GB<br />

Central Archive Server: ≥ 2 GB Central Archive Server: ≥ 2GB<br />

Client: 1 GB 2) Client: 512 MB<br />

WebClient/DataMonitor Client: 512 MB 2) WebClient/DataMonitor Client: 512 MB<br />

Graphics card<br />

Minimum 16 MB, <strong>80</strong>0 x 600 2) 16 MB, <strong>80</strong>0 x 600<br />

Recommended 32 MB, 12<strong>80</strong> x 1024 2) Hard disk<br />

32 MB, 12<strong>80</strong> x 1024<br />

Minimum Single-user station/server: 20 GB Single-user station/server: 20 GB<br />

Client: 5 GB Client: 5 GB<br />

Central Archive Server: 40 GB Central Archive Server: 40 GB<br />

WebClient/DataMonitor Client: 5 GB WebClient/DataMonitor Client: 5 GB<br />

Recommended Single-user station/server: <strong>80</strong> GB Single-user station/server: <strong>80</strong> GB<br />

Client: 20 GB Client: 20 GB<br />

Central Archive Server: 2 x <strong>80</strong> GB Central Archive Server: 2 x <strong>80</strong> GB<br />

Hard disk (free memory space for<br />

installation)<br />

WebClient/DataMonitor Client: 10 GB WebClient/DataMonitor Client: 10 GB<br />

- Minimum Server: >1.5 GB Server: 1.5 GB<br />

Client: 1.5 GB Client: 1 GB<br />

- Recommended Server: >10 GB Server: >10 GB<br />

Client: >1.5 GB Client: >1.5 GB<br />

CD ROM/DVD ROM/diskette drive/<br />

USB interface<br />

for software installation for software installation<br />

4/79<br />

4


4<br />

HMI Software<br />

SCADA system SIMATIC WinCC<br />

SIMATIC WinCC<br />

■ Technical specifications (continued)<br />

Type<br />

Functionality/quantity structure<br />

SIMATIC WinCC<br />

Number of messages 150,000<br />

Message text (number of<br />

characters)<br />

10 x 256<br />

Alarm log > 500,000 messages 1)<br />

Process values per message 10<br />

Constant load of messages, max. Central Archive Server: 100/s<br />

Server/single-user station: 10/s<br />

Message burst, max.<br />

Archives<br />

Server/single-user station:<br />

2,000/10 s every 5 min<br />

Archive data points Max. 120,000 per server 2)<br />

Archive types Short-term archive with and<br />

without long-term archiving<br />

Data storage format Microsoft SQL Server 2005<br />

Measured values per second,<br />

max.<br />

User archive<br />

Server/single-user station: 5,000/s<br />

Archives and views 500 each<br />

Product consisting of data record<br />

and column per user archive<br />

320,000<br />

Fields per user archive<br />

Graphics system<br />

500<br />

Number of screens System-limited 1)<br />

Number of objects per screen System-limited 1)<br />

Number of controllable fields per<br />

screen<br />

System-limited 1)<br />

1) Dependent on the available storage space<br />

2) Dependent on the number of licensed archive variables<br />

3) Dependent on number of licensed PowerTags<br />

4) Asian versions for Version 7 SP1 or higher<br />

5) The number of variables per report is dependent on<br />

process communication performance<br />

4/<strong>80</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

PowerTags 256 K 3)<br />

Trends<br />

Trend views per image 25<br />

Trends per trend view<br />

User administration<br />

<strong>80</strong><br />

User groups 128<br />

Number of users 128<br />

Authorization groups 999<br />

Configuration languages 5 European (Eng., Fr., Ger., It.,<br />

Sp.), 4 Asian<br />

(simpl.+trad. Chi/Kor/Jpn) 4)<br />

Protocols<br />

Message sequence reports<br />

(simultaneously)<br />

1 per server/single-user station<br />

Message archive reports<br />

(simultaneously)<br />

3<br />

User reports System-limited 1)<br />

Report lines per group 66<br />

Variables per report 300 5)<br />

Type SIMATIC WinCC<br />

Multi-user system<br />

Server 12<br />

Clients for server with operator<br />

station<br />

4<br />

Clients for server without operator 32 clients + 3 WebClients or<br />

station<br />

50 WebClients + 1 client


HMI Software<br />

SCADA system SIMATIC WinCC<br />

■ Ordering data Order No. Order No.<br />

SIMATIC WinCC system software<br />

V7.0 SP2<br />

Runtime packages on DVD<br />

Language/script versions:<br />

Ge, En, Fr, It, Sp; with license for<br />

WinCC RT Client 6AV6 381-2CA07-0AX0<br />

128 PowerTags (RT 128) 6AV6 381-2BC07-0AX0<br />

512 PowerTags (RT 512) 6AV6 381-2BD07-0AX0<br />

2048 PowerTags (RT 2048) 6AV6 381-2BE07-0AX0<br />

8192 PowerTags (RT 8192) 6AV6 381-2BH07-0AX0<br />

65536 PowerTags (RT 65536) 6AV6 381-2BF07-0AX0<br />

102400 PowerTags (RT 102400) 6AV6 381-2BJ07-0AX0<br />

153600 PowerTags (RT 153600) 6AV6 381-2BK07-0AX0<br />

262144 PowerTags (RT 262144)<br />

Incl. 512 archive tags each<br />

Complete packages on DVD<br />

Language versions:<br />

Ge, En, Fr, It, Sp; with license for<br />

6AV6 381-2BL07-0AX0<br />

WinCC RC Client 6AV6 381-2CB07-0AX0<br />

128 PowerTags (RC 128) 6AV6 381-2BM07-0AX0<br />

512 PowerTags (RC 512) 6AV6 381-2BN07-0AX0<br />

2048 PowerTags (RC 2048) 6AV6 381-2BP07-0AX0<br />

8192 PowerTags (RC 8192) 6AV6 381-2BS07-0AX0<br />

65536 PowerTags (RC 65536) 6AV6 381-2BQ07-0AX0<br />

102400 PowerTags (RC 102400) 6AV6 381-2BT07-0AX0<br />

153600 PowerTags (RC 153600) 6AV6 381-2BU07-0AX0<br />

262144 PowerTags (RC 262144)<br />

SIMATIC WinCC system software<br />

V7.0 SP2 ASIA<br />

Runtime packages on DVD<br />

Language/script versions:<br />

En, Chs, Cht, Kor, Jpn;<br />

with license for<br />

6AV6 381-2BV07-0AX0<br />

WinCC RT Client 6AV6 381-2CA07-0AV0<br />

128 PowerTags (RT 128) 6AV6 381-2BC07-0AV0<br />

512 PowerTags (RT 512) 6AV6 381-2BD07-0AV0<br />

2048 PowerTags (RT 2048) 6AV6 381-2BE07-0AV0<br />

8192 PowerTags (RT 8192) 6AV6 381-2BH07-0AV0<br />

65536 PowerTags (RT 65536) 6AV6 381-2BF07-0AV0<br />

102400 PowerTags (RT 102400) 6AV6 381-2BJ07-0AV0<br />

153600 PowerTags (RT 153600) 6AV6 381-2BK07-0AV0<br />

262144 PowerTags (RT 262144)<br />

Incl. 512 archive tags each<br />

Complete packages on DVD<br />

Language versions:<br />

En, Chs, Cht, Kor, Jpn;<br />

with license for<br />

6AV6 381-2BL07-0AV0<br />

WinCC RC Client 6AV6 381-2CB07-0AV0<br />

128 PowerTags (RC 128) 6AV6 381-2BM07-0AV0<br />

512 PowerTags (RC 512) 6AV6 381-2BN07-0AV0<br />

2048 PowerTags (RC 2048) 6AV6 381-2BP07-0AV0<br />

8192 PowerTags (RC 8192) 6AV6 381-2BS07-0AV0<br />

65536 PowerTags (RC 65536) 6AV6 381-2BQ07-0AV0<br />

102400 PowerTags (RC 102400) 6AV6 381-2BT07-0AV0<br />

153600 PowerTags (RC 153600) 6AV6 381-2BU07-0AV0<br />

262144 PowerTags (RC 262144)<br />

Clients<br />

6AV6 381-2BV07-0AV0<br />

RT Client ASIA 6AV6 381-2CA07-0AV0<br />

RT Client 6AV6 381-2CA07-0AX0<br />

RC Client ASIA 6AV6 381-2CB07-0AV0<br />

RC Client 6AV6 381-2CB07-0AX0<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC WinCC<br />

SIMATIC WinCC V7.0<br />

Power Packs<br />

For upgrading from:<br />

Runtime packages<br />

128 to 512 PowerTags 6AV6 371-2BD07-0AX0<br />

128 to 2048 PowerTags 6AV6 371-2BE07-0AX0<br />

128 to 8192 PowerTags 6AV6 371-2BK07-0AX0<br />

128 to 65536 PowerTags 6AV6 371-2BF07-0AX0<br />

512 to 2048 PowerTags 6AV6 371-2BG07-0AX0<br />

512 to 8192 PowerTags 6AV6 371-2BL07-0AX0<br />

512 to 65536 PowerTags 6AV6 371-2BH07-0AX0<br />

2048 to 8192 PowerTags 6AV6 371-2BM07-0AX0<br />

2048 to 65536 PowerTags 6AV6 371-2BJ07-0AX0<br />

8192 to 65536 PowerTags 6AV6 371-2BN07-0AX0<br />

65536 to 102400 PowerTags 6AV6 371-2BP07-0AX0<br />

102400 to 153600 PowerTags 6AV6 371-2BQ07-0AX0<br />

153600 to 262144 PowerTags<br />

Complete packages<br />

6AV6 371-2BR07-0AX0<br />

128 to 512 PowerTags 6AV6 371-2BD17-0AX0<br />

128 to 2048 PowerTags 6AV6 371-2BE17-0AX0<br />

128 to 8192 PowerTags 6AV6 371-2BK17-0AX0<br />

128 to 65536 PowerTags 6AV6 371-2BF17-0AX0<br />

512 to 2048 PowerTags 6AV6 371-2BG17-0AX0<br />

512 to 8192 PowerTags 6AV6 371-2BL17-0AX0<br />

512 to 65536 PowerTags 6AV6 371-2BH17-0AX0<br />

2048 to 8192 PowerTags 6AV6 371-2BM17-0AX0<br />

2048 to 65536 PowerTags 6AV6 371-2BJ17-0AX0<br />

8192 to 65536 PowerTags 6AV6 371-2BN17-0AX0<br />

65536 to 102400 PowerTags 6AV6 371-2BP17-0AX0<br />

102400 to 153600 PowerTags 6AV6 371-2BQ17-0AX0<br />

153600 to 262144 PowerTags<br />

SIMATIC WinCC V7.0 Archive<br />

6AV6 371-2BR17-0AX0<br />

1500 archives 6AV6 371-1DQ17-0AX0<br />

5000 archives 6AV6 371-1DQ17-0BX0<br />

10000 archives 6AV6 371-1DQ17-0CX0<br />

30000 archives 6AV6 371-1DQ17-0EX0<br />

<strong>80</strong>000 archives 6AV6 371-1DQ17-0GX0<br />

120000 archives<br />

SIMATIC WinCC V7.0 Archive<br />

Power Packs<br />

For upgrading archiving from<br />

6AV6 371-1DQ17-0JX0<br />

1500 to 5000 archive tags 6AV6 371-1DQ17-0AB0<br />

5000 to 10000 archive tags 6AV6 371-1DQ17-0BC0<br />

10000 to 30000 archive tags 6AV6 371-1DQ17-0CE0<br />

30000 to <strong>80</strong>000 archive tags 6AV6 371-1DQ17-0EG0<br />

<strong>80</strong>000 to 120000 archive tags 6AV6 371-1DQ17-0GJ0<br />

Bundles with SIMATIC HMI I<strong>PC</strong>477C and WinCC V7.0 SP1<br />

The SIMATIC HMI I<strong>PC</strong>477C with preinstalled WinCC can be<br />

found under HMI I<strong>PC</strong>477C or under Packages.<br />

4/81<br />

4


4<br />

HMI Software<br />

SCADA system SIMATIC WinCC<br />

SIMATIC WinCC<br />

■ Ordering data Order No. Order No.<br />

SIMATIC WinCC Upgrade/<br />

Software Update Service<br />

SIMATIC WinCC V7 upgrade 1)<br />

For upgrading the RT version<br />

from V6.0 to V7.0 SP2 B 6AV6 381-2AA07-0AX4<br />

from V6.2 to V7.0 SP2 B 6AV6 381-2AA07-0AX3<br />

from V6.0 ASIA to V7.0 SP2 ASIA 6AV6 381-2AA07-0AV4<br />

from V6.2 ASIA to V7.0 SP2 ASIA<br />

For upgrading the Client RT<br />

version<br />

6AV6 381-2AA07-0AV3<br />

from V6.0 to V7.0 SP2 B 6AV6 381-2BC07-0AX4<br />

from V6.2 to V7.0 SP2 B 6AV6 381-2BC07-0AX3<br />

from V6.0 ASIA to V7.0 SP2 ASIA 6AV6 381-2BC07-0AV4<br />

from V6.2 ASIA to V7.0 SP2 ASIA<br />

For upgrading the RC version<br />

6AV6 381-2BC07-0AV3<br />

from V6.0 to V7.0 SP2 B 6AV6 381-2AB07-0AX4<br />

from V6.2 to V7.0 SP2 B 6AV6 381-2AB07-0AX3<br />

from V6.0 ASIA to V7.0 SP2 ASIA 6AV6 381-2AB07-0AV4<br />

from V6.2 ASIA to V7.0 SP2 ASIA 6AV6 381-2AB07-0AV3<br />

SIMATIC WinCC Software Update<br />

Service (SUS) 2) 3)<br />

SIMATIC WinCC V7 Update<br />

for upgrade from V7.0 to V7.0 SP2<br />

(only on DVD)<br />

Software Update Service for<br />

WinCC basic software and<br />

options:<br />

S79220-B2503-P<br />

1 license 6AV6 381-1AA00-0AX5<br />

3 licenses 6AV6 381-1AA00-0BX5<br />

10 licenses<br />

SIMATIC WinCC system software<br />

V6.2 SP3<br />

Runtime packages on CD-ROM<br />

Language/script versions: Ge,<br />

En, Fr, It, Sp; with license for<br />

6AV6 381-1AA00-0CX5<br />

128 PowerTags (RT 128) 6AV6 381-1BC06-2AX0<br />

256 PowerTags (RT 256) 6AV6 381-1BD06-2AX0<br />

1024 PowerTags (RT 1024) 6AV6 381-1BE06-2AX0<br />

8192 PowerTags (RT 8192) 6AV6 381-1BH06-2AX0<br />

65536 PowerTags (RT 65536) 6AV6 381-1BF06-2AX0<br />

102400 PowerTags (RT 102400) 6AV6 381-1BJ06-2AX0<br />

153600 PowerTags (RT 153600) 6AV6 381-1BK06-2AX0<br />

262144 PowerTags (RT 262144)<br />

Incl. 512 archive tags each<br />

Complete packages on<br />

CD-ROM<br />

Language versions: Ge, En, Fr, It,<br />

Sp; with license for<br />

6AV6 381-1BL06-2AX0<br />

128 PowerTags (RC 128) 6AV6 381-1BM06-2AX0<br />

256 PowerTags (RC 256) 6AV6 381-1BN06-2AX0<br />

1024 PowerTags (RC 1024) 6AV6 381-1BP06-2AX0<br />

8192 PowerTags (RC 8192) 6AV6 381-1BS06-2AX0<br />

65536 PowerTags (RC 65536) 6AV6 381-1BQ06-2AX0<br />

102400 PowerTags (RC 102400) 6AV6 381-1BT06-2AX0<br />

153600 PowerTags (RC 153600) 6AV6 381-1BU06-2AX0<br />

262144 PowerTags (RC 262144)<br />

Incl. 512 archive tags each<br />

6AV6 381-1BV06-2AX0<br />

4/82<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC WinCC system software<br />

V6.2 SP3 ASIA<br />

Runtime packages on CD-ROM<br />

Language versions: English/<br />

simplified and traditional Chinese/<br />

Korean/Taiwanese/Japanese; with<br />

license for<br />

128 PowerTags (RT 128) 6AV6 381-1BC06-2AV0<br />

256 PowerTags (RT 256) 6AV6 381-1BD06-2AV0<br />

1024 PowerTags (RT 1024) 6AV6 381-1BE06-2AV0<br />

8192 PowerTags (RT 8192) 6AV6 381-1BH06-2AV0<br />

65536 PowerTags (RT 65536) 6AV6 381-1BF06-2AV0<br />

Incl. 512 archive tags each<br />

Complete packages on<br />

CD-ROM<br />

Language versions: English/<br />

simplified and traditional Chinese/<br />

Korean/Taiwanese, Japanese;<br />

with license for<br />

128 PowerTags (RC 128) 6AV6 381-1BM06-2AV0<br />

256 PowerTags (RC 256) 6AV6 381-1BN06-2AV0<br />

1024 PowerTags (RC 1024) 6AV6 381-1BP06-2AV0<br />

8192 PowerTags (RC 8192) 6AV6 381-1BS06-2AV0<br />

65536 PowerTags (RC 65536) 6AV6 381-1BQ06-2AV0<br />

Incl. 512 archive tags each<br />

SIMATIC WinCC V6.2 Power<br />

Packs<br />

For upgrading from:<br />

Runtime packages<br />

128 to 256 PowerTags 6AV6 371-1BD06-2AX0<br />

128 to 1024 PowerTags 6AV6 371-1BE06-2AX0<br />

128 to 8192 PowerTags 6AV6 371-1BK06-2AX0<br />

128 to 65536 PowerTags 6AV6 371-1BF06-2AX0<br />

256 to 1024 PowerTags 6AV6 371-1BG06-2AX0<br />

256 to 8192 PowerTags 6AV6 371-1BL06-2AX0<br />

256 to 65536 PowerTags 6AV6 371-1BH06-2AX0<br />

1024 to 8192 PowerTags 6AV6 371-1BM06-2AX0<br />

1024 to 65536 PowerTags 6AV6 371-1BJ06-2AX0<br />

8192 to 65536 PowerTags 6AV6 371-1BN06-2AX0<br />

Complete packages<br />

128 to 256 PowerTags 6AV6 371-1BD16-2AX0<br />

128 to 1024 PowerTags 6AV6 371-1BE16-2AX0<br />

128 to 8192 PowerTags 6AV6 371-1BK16-2AX0<br />

128 to 65536 PowerTags 6AV6 371-1BF16-2AX0<br />

256 to 1024 PowerTags 6AV6 371-1BG16-2AX0<br />

256 to 8192 PowerTags 6AV6 371-1BL16-2AX0<br />

256 to 65536 PowerTags 6AV6 371-1BH16-2AX0<br />

1024 to 8192 PowerTags 6AV6 371-1BM16-2AX0<br />

1024 to 65536 PowerTags 6AV6 371-1BJ16-2AX0<br />

8192 to 65536 PowerTags 6AV6 371-1BN16-2AX0<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

1) According to licensing provisions, 1 upgrade package must be<br />

ordered for each WinCC station<br />

2) The Software Update Service is valid for 1 year. The contract is<br />

automatically extended by 1 more year unless canceled 3 months<br />

prior to expiration. According to licensing provisions, 1 Software<br />

Update Service must be ordered for each WinCC station.<br />

3) Requires the current software version


HMI Software<br />

SCADA system SIMATIC WinCC<br />

■ Ordering data Order No. Order No.<br />

SIMATIC WinCC V6.2 Archive<br />

1500 archives 6AV6 371-1DQ16-2AX0<br />

5000 archives 6AV6 371-1DQ16-2BX0<br />

10000 archives 6AV6 371-1DQ16-2CX0<br />

30000 archives 6AV6 371-1DQ16-2EX0<br />

<strong>80</strong>000 archives 6AV6 371-1DQ16-2GX0<br />

120000 archives<br />

SIMATIC WinCC V6.2 Archive<br />

Power Packs<br />

For upgrading archiving from<br />

6AV6 371-1DQ16-2JX0<br />

1500 to 5000 archive tags 6AV6 371-1DQ16-2AB0<br />

5000 to 10000 archive tags 6AV6 371-1DQ16-2BC0<br />

10000 to 30000 archive tags 6AV6 371-1DQ16-2CE0<br />

30000 to <strong>80</strong>000 archive tags 6AV6 371-1DQ16-2EG0<br />

<strong>80</strong>000 to 120000 archive tags<br />

SIMATIC WinCC V6.2 Upgrade<br />

6AV6 371-1DQ16-2GJ0<br />

1)<br />

For upgrading the RT version<br />

from V5.x to V6.2 SP3 B 6AV6 381-1AA06-2AX4<br />

from V6.x to V6.2 SP3 B 6AV6 381-1AA06-2AX3<br />

from V5.x ASIA to V6.2 SP3 ASIA B 6AV6 381-1AA06-2AV4<br />

from V6.x ASIA to V6.2 SP3 ASIA B<br />

For upgrading the RC version<br />

6AV6 381-1AA06-2AV3<br />

from V5.x to V6.2 SP3 B 6AV6 381-1AB06-2AX4<br />

from V6.x to V6.2 SP3 B 6AV6 381-1AB06-2AX3<br />

from V5.x ASIA to V6.2 SP3 ASIA B 6AV6 381-1AB06-2AV4<br />

from V6.x ASIA to V6.2 SP3 ASIA B 6AV6 381-1AB06-2AV3<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

1) According to licensing provisions, 1 upgrade package must be<br />

ordered for each WinCC station.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC WinCC<br />

SIMATIC WinCC V7.0 SP2 communication<br />

Communication via Industrial<br />

Ethernet<br />

CP 1612 A2<br />

<strong>PC</strong>I card (32-bit) for connection of<br />

PG/<strong>PC</strong> to Industrial Ethernet<br />

(10/100/1000 Mbit/s) with RJ45<br />

connection via SOFTNET S7 and<br />

SOFTNET PG<br />

SOFTNET-S7 Version 8.0 SP1 /<br />

Edition 2008 SP2 (V7.1)<br />

Software for S7 and<br />

S5-compatible communication,<br />

incl. O<strong>PC</strong> server,<br />

PG/OP communication and<br />

NCM <strong>PC</strong>; up to 64 connections,<br />

single license for 1 installation,<br />

runtime software, software and<br />

electronic manual on CD-ROM,<br />

license key on USB stick, Class A<br />

Version 8.0 SP1<br />

for (32-bit) Windows 7 Ultimate,<br />

Professional; for CP 1612;<br />

CP 1612 A2 German/English<br />

Edition 2008 SP2 (V7.1)<br />

for (32-bit) Windows XP<br />

Professional,<br />

Windows Server 2003,<br />

VI<strong>ST</strong>A Ultimate/Business;<br />

for CP 1612;<br />

CP 1612 A2 German/English<br />

B 6GK1 161-2AA01<br />

Single license for 1 installation D 6GK1 704-1CW<strong>80</strong>-3AA0<br />

Upgrade package<br />

for SIMATIC NET Edition 2006 or<br />

higher<br />

D 6GK1 704-1CW00-3AE0<br />

Upgrade package<br />

for SIMATIC NET V6.0, V6.1,<br />

V6.2, and Edition 2005<br />

D 6GK1 704-1CW00-3AE1<br />

SOFTNET-S7 Lean Version 8.0<br />

SP1 / Edition 2008 SP2 (V7.1)<br />

(included in scope of delivery of<br />

WinCC V7.0 SP2)<br />

Software for S7 and<br />

S5-compatible communication,<br />

incl. O<strong>PC</strong> server,<br />

PG/OP communication and<br />

NCM <strong>PC</strong>; up to 8 connections,<br />

single license for 1 installation,<br />

runtime software, software and<br />

electronic manual on CD-ROM,<br />

license key on USB stick, Class A<br />

Version 8.0 SP1<br />

for (32-bit) Windows 7 Ultimate,<br />

Professional; for CP 1612;<br />

CP 1612 A2 German/English<br />

Edition 2008 SP2 (V7.1)<br />

for (32-bit) Windows XP<br />

Professional,<br />

Windows Server 2003,<br />

VI<strong>ST</strong>A Ultimate/Business;<br />

for CP 1612;<br />

CP 1612 A2 German/English<br />

Single license for 1 installation D 6GK1 704-1LW<strong>80</strong>-3AA0<br />

Upgrade package<br />

for SIMATIC NET Edition 2006 or<br />

higher<br />

D 6GK1 704-1LW00-3AE0<br />

Upgrade package<br />

for SIMATIC NET V6.0, V6.1,<br />

V6.2, and Edition 2005<br />

D 6GK1 704-1LW00-3AE1<br />

4/83<br />

4


4<br />

HMI Software<br />

SCADA system SIMATIC WinCC<br />

SIMATIC WinCC<br />

■ Ordering data Order No. Order No.<br />

CP 1613 A2<br />

<strong>PC</strong>I card (32-bit) for connecting a<br />

PG/<strong>PC</strong> to Industrial Ethernet<br />

(communications software must<br />

be ordered separately)<br />

6GK1 161-3AA01<br />

CP 1623<br />

<strong>PC</strong>I Express X1 card (32-bit)<br />

for connection of PG/<strong>PC</strong> to<br />

Industrial Ethernet<br />

(communications software to be<br />

ordered separately)<br />

S7-1613 Version 8.0 SP1 /<br />

Edition 2008 SP2 (V7.1)<br />

Software for S7 and<br />

S5-compatible communication,<br />

incl. PG/OP communication,<br />

O<strong>PC</strong> server and NCM <strong>PC</strong>; up to<br />

120 connections, single license<br />

for 1 installation, runtime software,<br />

software and electronic manual<br />

on CD-ROM, license key on USB<br />

stick, Class A<br />

Version 8.0 SP1<br />

for (32-bit) Windows 7 Ultimate,<br />

Professional; for CP 1613;<br />

CP 1613 A2,<br />

CP 1623 German/English<br />

Edition 2008 SP2 (V7.1)<br />

for (32-bit)<br />

Windows XP Professional,<br />

Windows Server 2003,<br />

VI<strong>ST</strong>A Ultimate/Business;<br />

for CP 1613; CP 1613 A2,<br />

CP 1623 German/English<br />

6GK1 162-3AA00<br />

Single license for 1 installation D 6GK1 716-1CB<strong>80</strong>-3AA0<br />

Upgrade package<br />

for SIMATIC NET Edition 2006 or<br />

higher<br />

D 6GK1 716-1CB00-3AE0<br />

Upgrade package<br />

for SIMATIC NET V6.0, V6.1,<br />

V6.2, and Edition 2005<br />

D 6GK1 716-1CB00-3AE1<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

4/84<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Communication via PROFIBUS<br />

CP 5611 A2<br />

<strong>PC</strong>I card (32-bit) for connecting a<br />

PG/<strong>PC</strong> to PROFIBUS (communications<br />

software included in the<br />

WinCC basic package)<br />

6GK1 561-1AA01<br />

CP 5621<br />

<strong>PC</strong>I Express X1 card (32-bit)<br />

for connection of PG/<strong>PC</strong> to<br />

PROFIBUS (communications<br />

software included in WinCC basic<br />

package)<br />

E 6GK1 562-1AA00<br />

CP 5621 MPI<br />

Comprising CP 5621 (32-bit) and<br />

MPI cable, 5 m<br />

E 6GK1 562-1AM00<br />

CP 5512<br />

<strong>PC</strong>MCIA card (CARDBUS 32-bit)<br />

for the connection of a PG/<br />

notebook to PROFIBUS or MPI<br />

(communications software<br />

included in WinCC basic<br />

package)<br />

6GK1 551-2AA00<br />

CP 5711<br />

USB adapter (USB V2.0)<br />

for connecting a PG or Notebook<br />

to PROFIBUS or MPI<br />

(2 m USB cable and<br />

5 m MPI cable included)<br />

A 6GK1 571-1AM00<br />

CP 5613 A2<br />

<strong>PC</strong>I card (32-bit) for connecting a<br />

<strong>PC</strong> to PROFIBUS (communications<br />

software must be ordered<br />

separately).<br />

6GK1 561-3AA01<br />

CP 5623<br />

<strong>PC</strong>I Express X1 card (32-bit)<br />

for connection of PG/<strong>PC</strong> to<br />

Industrial Ethernet<br />

(communications software to be<br />

ordered separately)<br />

S7-5613 Version 8.0 SP1 /<br />

Edition 2008 SP2 (V7.1)<br />

Software for S7 Communication<br />

incl. PG/OP protocol, FDL,<br />

O<strong>PC</strong> server; runtime software,<br />

software and electronic manual<br />

on CD-ROM, license key on USB<br />

stick, Class A<br />

Version 8.0 SP1<br />

for (32-bit) Windows 7 Ultimate,<br />

Professional; for CP 5613 A2,<br />

CP 5623 German/English<br />

Edition 2008 SP2 (V7.1)<br />

for (32-bit)<br />

Windows XP Professional,<br />

Windows Server 2003,<br />

VI<strong>ST</strong>A Ultimate/Business;<br />

for CP 5613 A2;<br />

CP 5623 German/English<br />

E 6GK1 562-3AA00<br />

Single license for 1 installation D 6GK1 713-5CB<strong>80</strong>-3AA0<br />

Upgrade package for<br />

SIMATIC NET Edition 2006 or<br />

higher<br />

D 6GK1 713-5CB00-3AE0<br />

Upgrade package<br />

for SIMATIC NET V6.0, V6.1,<br />

V6.2, and Edition 2005<br />

D 6GK1 713-5CB00-3AE1


HMI Software<br />

SCADA system SIMATIC WinCC<br />

■ Ordering data Order No. Order No.<br />

DP-5613 Version 8.0 SP1 /<br />

Edition 2008 SP2 (V7.1)<br />

Software for DP protocol<br />

incl. PG/OP communication, FDL,<br />

O<strong>PC</strong> server, runtime software,<br />

software and electronic manual<br />

on CD-ROM, license key on USB<br />

stick, Class A<br />

Version 8.0 SP1<br />

for (32-bit) Windows 7 Ultimate,<br />

Professional; for CP 5613 A2,<br />

CP 5623 German/English<br />

Edition 2008 SP2 (V7.1)<br />

for (32-bit)<br />

Windows XP Professional,<br />

Windows Server 2003,<br />

VI<strong>ST</strong>A Ultimate/Business;<br />

for CP 5613 A2;<br />

CP 5623 German/English<br />

Single license for 1 installation D 6GK1 713-5DB<strong>80</strong>-3AA0<br />

Upgrade package<br />

for SIMATIC NET Edition 2006 or<br />

higher<br />

D 6GK1 713-5DB00-3AE0<br />

Upgrade package<br />

for SIMATIC NET V6.0, V6.1,<br />

V6.2, and Edition 2005<br />

D 6GK1 713-5DB00-3AE1<br />

FMS-5613 Edition 2008 SP2<br />

(V7.1)<br />

Software for FMS protocol incl.<br />

PG/OP communication, FDL,<br />

O<strong>PC</strong> server, runtime software,<br />

software and electronic manual<br />

on CD-ROM, license key on<br />

USB stick, Class A, for 32-bit:<br />

Windows XP Professional,<br />

Windows Server 2003, Windows<br />

VI<strong>ST</strong>A Ultimate/Business;<br />

for CP 5613 A2,<br />

CP 5623 German/English<br />

Single license for 1 installation D 6GK1 713-5FB71-3AA0<br />

Upgrade package<br />

for SIMATIC NET Edition 2006 or<br />

higher<br />

D 6GK1 713-5FB00-3AE0<br />

Upgrade package<br />

for SIMATIC NET V6.0, V6.1,<br />

V6.2, and Edition 2005<br />

D 6GK1 713-5FB00-3AE1<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

1) According to licensing provisions, 1 upgrade package must be<br />

ordered for each WinCC station.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC WinCC<br />

SIMATIC WinCC V6.2 communication<br />

Communication via Industrial<br />

Ethernet<br />

CP 1612 A2<br />

<strong>PC</strong>I card (32-bit) for connecting<br />

a PG/<strong>PC</strong> to Industrial Ethernet<br />

(communications software must<br />

be ordered separately)<br />

SOFTNET-S7 Edition 2006<br />

Software for S7 and<br />

S5-compatible communication,<br />

incl. O<strong>PC</strong> server,<br />

PG/OP communication and<br />

NCM <strong>PC</strong>; up to 64 connections,<br />

single license for 1 installation,<br />

runtime software, software and<br />

electronic manual on CD-ROM,<br />

license key on USB stick, Class A,<br />

for 32-bit: Windows XP<br />

Professional/2000 Professional/<br />

Server for CP 1512/CP 1612;<br />

German/English<br />

6GK1 161-2AA00<br />

Single license for 1 installation 6GK1 704-1CW64-3AA0<br />

Upgrade package<br />

for SIMATIC NET Edition 2007<br />

Upgrade package for SIMATIC<br />

NET V6.0, V6.1, V6.2, and<br />

Edition 2005 1)<br />

D 6GK1 704-1CW00-3AE1<br />

SOFTNET-S7 Lean Edition 2006<br />

(included in the scope of supply<br />

of WinCC V6.2)<br />

Software for S7 and<br />

S5-compatible communication,<br />

incl. O<strong>PC</strong> server,<br />

PG/OP communication and<br />

NCM <strong>PC</strong>; up to 8 connections,<br />

single license for 1 installation,<br />

runtime software, software and<br />

electronic manual on CD-ROM,<br />

license key on USB stick, Class A,<br />

for 32-bit: Windows XP<br />

Professional/2000 Professional/<br />

Server for CP 1512/CP 1612;<br />

German/English<br />

Single license for 1 installation 6GK1 704-1LW64-3AA0<br />

Upgrade package<br />

for SIMATIC NET Edition 2007<br />

Upgrade package for SIMATIC<br />

NET V6.0, V6.1, V6.2, and<br />

Edition 2005 1)<br />

D 6GK1 704-1LW00-3AE1<br />

CP 1613 A2 6GK1 161-3AA01<br />

<strong>PC</strong>I card (32-bit) for connecting a<br />

PG/<strong>PC</strong> to Industrial Ethernet<br />

(communications software must<br />

be ordered separately)<br />

4/85<br />

4


4<br />

HMI Software<br />

SCADA system SIMATIC WinCC<br />

SIMATIC WinCC<br />

■ Ordering data Order No. Order No.<br />

S7-1613 Edition 2006<br />

Software for S7 and<br />

S5-compatible communication,<br />

incl. O<strong>PC</strong> server, PG/OP communication<br />

and NCM <strong>PC</strong>; up to<br />

120 connections, single license<br />

for 1 installation, runtime software,<br />

software and electronic manual<br />

on CD-ROM, license key on USB<br />

stick, Class A, for 32-bit:<br />

Windows XP Professional,<br />

Windows 2003 Server, Windows<br />

VI<strong>ST</strong>A Ultimate/Business; for<br />

CP 1613, CP 1613 A2, CP 1623;<br />

German/English<br />

Single license for 1 installation 6GK17 16-1CB64-3AA0<br />

for SIMATIC NET Edition 2007<br />

Upgrade package for SIMATIC<br />

NET V6.0, V6.1, V6.2, and<br />

Edition 2005 1)<br />

D 6GK17 16-1CB00-3AE1<br />

T7-1613 Edition 2006<br />

Software for TF protocol,<br />

S5-compatible communication,<br />

incl. O<strong>PC</strong>, PG/OP communication<br />

(S5/505 Layer 4 communication<br />

with TCP/IP), for Windows XP<br />

Professional/2003 Server/2000<br />

Professional/Server<br />

Single license for 1 installation 6GK1 716-1TB64-3AA0<br />

Upgrade package<br />

for SIMATIC NET Edition 2007<br />

Upgrade package for SIMATIC<br />

NET V6.0, V6.1, V6.2, and<br />

Edition 2005 1)<br />

D 6GK1 716-1CB00-3AE1<br />

Communication via PROFIBUS<br />

CP 5611 A2<br />

<strong>PC</strong>I card (32-bit) for connecting a<br />

PG/<strong>PC</strong> to PROFIBUS (communications<br />

software included in the<br />

WinCC basic package)<br />

6GK1 561-1AA01<br />

CP 5621<br />

<strong>PC</strong>I Express X1 card (32-bit) for<br />

connection of PG/<strong>PC</strong> to<br />

PROFIBUS (communications<br />

software included in WinCC basic<br />

package)<br />

E 6GK1 562-1AA00<br />

CP 5611 MPI<br />

Comprising CP 5611 A2 and MPI<br />

cable, 5 m<br />

A 6GK1 561-1AM01<br />

CP 5621 MPI<br />

Comprising CP 5621 (32-bit) and<br />

MPI cable, 5 m<br />

E 6GK1 562-1AM00<br />

CP 5512<br />

<strong>PC</strong>MCIA card (CARDBUS 32-bit)<br />

for the connection of a PG/<br />

notebook to PROFIBUS or MPI<br />

(communications software<br />

included in WinCC basic<br />

package)<br />

6GK1 551-2AA00<br />

CP 5711<br />

USB adapter (USB V2.0) for<br />

connecting a PG or Notebook to<br />

PROFIBUS or MPI (2 m USB<br />

cable and 5 m MPI cable<br />

included)<br />

A 6GK1 571-1AM00<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

N: Subject to export regulations: AL: N and ECCN: 7A994A<br />

4/86<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

CP 5613 A2 6GK1 561-3AA01<br />

<strong>PC</strong>I card (32-bit) for connecting a<br />

<strong>PC</strong> to PROFIBUS (communications<br />

software must be ordered<br />

separately).<br />

S7-5613 Edition 2006<br />

Software for S7 communication<br />

incl. PG/OP communication, FDL,<br />

O<strong>PC</strong> server; for Windows XP<br />

Professional/2003 Server/<br />

2000 Professional/Server for<br />

CP 5613/CP 5614; English/<br />

German<br />

Single license for 1 installation 6GK1 713-5CB64-3AA0<br />

Upgrade package<br />

for SIMATIC NET Edition 2007<br />

Upgrade package for SIMATIC<br />

NET V6.0, V6.1, V6.2, and<br />

Edition 2005 1)<br />

6GK1 713-1CB00-3AE1<br />

DP-5613 Edition 2006<br />

Software for DP protocol<br />

incl. PG/OP communication, FDL,<br />

O<strong>PC</strong> server, runtime software,<br />

software and electronic manual<br />

on CD-ROM, license key on<br />

USB stick, Class A, for 32-bit:<br />

Windows XP Professional,<br />

Windows 2003 Server, Windows<br />

VI<strong>ST</strong>A Ultimate/Business;<br />

for CP 5613 A2; German/English<br />

Single license for 1 installation 6GK1 713-5DB64-3AA0<br />

Upgrade package<br />

for SIMATIC NET Edition 2007<br />

Upgrade package for<br />

SIMATIC NET V6.0, V6.1, V6.2,<br />

and Edition 2005 1)<br />

6GK1 713-1DB00-3AE1<br />

FMS-5613 Edition 2006<br />

Software for FMS protocol incl.<br />

PG/OP communication, FDL,<br />

FMS-O<strong>PC</strong> server, for Windows XP<br />

Professional/2003 Server/<br />

2000 Professional/Server for<br />

CP 5613/CP 5614; English/<br />

German<br />

Single license for 1 installation 6GK1 713-5FB64-3AA0<br />

Upgrade package<br />

for SIMATIC NET Edition 2007<br />

Upgrade package for<br />

SIMATIC NET V6.0, V6.1, V6.2,<br />

and Edition 2005 1)<br />

D 6GK1 713-5FB00-3AE1<br />

1) The licenses supplied with SIMATIC NET Edition 2007 are also valid<br />

for the version SIMATIC NET Edition 2006. The software SIMATIC NET<br />

Edition 2006 is supplied with WinCC V6.<br />

Hardware for process control functions<br />

DCF-77 receiver<br />

for time synchronization<br />

DCF77 (Europe) 2XV9 450-1AR14<br />

GPS (worldwide)<br />

Multi-VGA<br />

N 2XV9 450-1AR13<br />

2 screens A 6ES7 652-0XX03-1XE0<br />

4 screens A 6ES7 652-0XX03-1XE1<br />

Note:<br />

For further information about process control options, see<br />

<strong>Catalog</strong> <strong>ST</strong> <strong>PC</strong>S7


■ More information<br />

WinCC language versions<br />

SIMATIC WinCC is also offered in simplified Chinese, traditional<br />

Chinese, Korean and Japanese, especially for Asian markets.<br />

These WinCC versions are intended for machine manufacturers,<br />

plant constructors and exporters who supply the regions of<br />

China, Taiwan, Korea and Japan.<br />

WinCC ASIA includes all familiar WinCC functions and offers in<br />

addition the configuration user interface in the respective<br />

national language and English. The online Help is available in<br />

simplified Chinese, traditional Chinese, Korean, Japanese and<br />

English. A Chinese, Korean, Japanese or multilingual Windows<br />

operating system is required for operation.<br />

WinCC ASIA is delivered on a separate DVD which contains all<br />

of the above mentioned language versions. The corresponding<br />

documentations can be obtained from the national subsidiaries<br />

in China, Korea, Taiwan and Japan.<br />

The runtime licenses are language-neutral. The English handling<br />

program (Automation License Manager – ALM) is executable<br />

under the Chinese, Korean and Japanese Windows versions.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SCADA system SIMATIC WinCC<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC WinCC<br />

Additional information is available in the Internet under:<br />

www.siemens.com/wincc<br />

Separate configurators are available for <strong>PC</strong> hardware:<br />

SIMATIC I<strong>PC</strong>547C, SIMATIC Rack <strong>PC</strong> 547B<br />

SIMATIC I<strong>PC</strong>647C, SIMATIC Rack <strong>PC</strong> 647B<br />

SIMATIC I<strong>PC</strong>847C, SIMATIC Rack <strong>PC</strong> 847B<br />

SIMATIC I<strong>PC</strong>427C<br />

SIMATIC I<strong>PC</strong>627C, SIMATIC Box <strong>PC</strong> 627B<br />

SIMATIC Box <strong>PC</strong> 827B<br />

SIMATIC HMI I<strong>PC</strong>577C, SIMATIC Panel <strong>PC</strong> 577B<br />

SIMATIC HMI I<strong>PC</strong>677C, SIMATIC Panel <strong>PC</strong> 677B<br />

4/87<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC options<br />

SIMATIC WinCC options<br />

■ Overview<br />

The universal WinCC basic software is the basis for modular<br />

expansions. These functional expansions can be obtained in the<br />

form of WinCC options and as WinCC Premium add-ons.<br />

WinCC options are created by WinCC Development and are<br />

<strong>Siemens</strong> Industry Automation products. You can obtain support<br />

from our Advisory Services and via the central hotline.<br />

Options for scalable plant configurations<br />

WinCC/Server<br />

For configuring a powerful client/server system<br />

WinCC/Web Navigator<br />

For controlling and monitoring plants via the Internet,<br />

in-house intranet or LAN<br />

WinCC/TeleControl<br />

For connecting to outlying stations<br />

(Remote Terminal Units = RTUs) via telecontrol protocols<br />

in a WinCC SCADA system<br />

WinCC/Central Archive Server (CAS)<br />

For configuring a central archive server<br />

Options for increasing the availability<br />

WinCC/Redundancy<br />

For increasing system availability through redundancy<br />

SIMATIC Maintenance Station<br />

For system-integrated diagnostics and plant asset<br />

management<br />

WinCC/ProAgent<br />

For reliable process diagnostics<br />

4/88<br />

WinCC<br />

Option<br />

WinCC<br />

Option<br />

WinCC<br />

Add-on<br />

WinCC<br />

Basic SW<br />

RC, RT<br />

WinCC<br />

Add-on<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

WinCC<br />

Option<br />

WinCC<br />

Add-on<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00175<br />

Option for energy management<br />

SIMATIC powerrate<br />

Ensures transparency in energy consumption from<br />

the infeed through to the load<br />

WinCC/B.Data<br />

Modular and sector-neutral energy management and<br />

plant information system for industrial plants.<br />

Options for IT and Business Integration – Plant Intelligence<br />

WinCC/DataMonitor<br />

For displaying and evaluating current process states and<br />

historical data on office <strong>PC</strong>s with standard tools<br />

WinCC/DowntimeMonitor<br />

For detecting and analyzing downtimes for machines and<br />

plants<br />

WinCC/Connectivity Pack<br />

Access to WinCC archives via O<strong>PC</strong> HDA, O<strong>PC</strong> A&E,<br />

O<strong>PC</strong> XML Server and WinCC OLE-DB /OLE-DB<br />

WinCC/Connectivity Station<br />

Gateway to WinCC server data over O<strong>PC</strong> HDA, O<strong>PC</strong> A&E,<br />

O<strong>PC</strong> XML server and WinCC OLE-DB /OLE-DB from<br />

independent computers<br />

WinCC/IndustrialDataBridge<br />

Configurable connection to databases and IT systems<br />

Options for SCADA expansions<br />

WinCC/User Archives<br />

For managing data records in user archives<br />

WinCC/Calendar Scheduler<br />

Calendar-based planning of events<br />

Options for sector-specific expansions<br />

SIMATIC BATCH (for WinCC)<br />

- WinCC in combination with the SIMATIC BATCH products<br />

offers the solution for implementation of batch processes in<br />

accordance with ISA S88.<br />

- Batch processes which place heterogeneous demands on<br />

the interfacing of different types of PLC, such as<br />

S7-400/300, S5 and third-party PLCs, are automated using<br />

SIMATIC BATCH (for WinCC).<br />

WinCC/ChangeControl<br />

- Change and version management<br />

- Generation of audit trails for engineering<br />

WinCC/Audit<br />

- Change management<br />

- Generation of audit trails for engineering and runtime<br />

SIMATIC Logon<br />

- Central management of WinCC users, plant-wide (to<br />

CFR 21 Part 11)<br />

Options for individual system expansions<br />

WinCC/IndustrialX<br />

For creating customized WinCC ActiveX objects in<br />

a VB development environment and .net.<br />

WinCC/ODK<br />

For the use of open programming interfaces<br />

(Open Development Kit)<br />

■ More information<br />

WinCC options<br />

www.siemens.com/wincc/options


■ Overview<br />

WinCC Server<br />

TERMINAL BUS TCP/IP<br />

PROCESS BUS<br />

Option for SIMATIC WinCC, which permits the configuration of<br />

a powerful client/server system<br />

One of the following operating systems must be available to<br />

install the option on the server: Windows Server 2003 (for V6)<br />

or Windows Server 2003 R2 (for V6.2 / V7.0) or Windows<br />

Server 2008 (for V7.0 with SP2 and higher). When using<br />

Windows XP Professional, max. 3 clients can be connected.<br />

A number of coordinated operator control and monitoring<br />

stations can be operated in a single group with networked<br />

automation systems<br />

Client/server solution:<br />

- One server can supply up to 32 connected clients with<br />

process and archive data, messages, images and reports<br />

- Depending on the size of the plant, up to 12 servers can be<br />

used<br />

- 32 clients per server are possible<br />

Requirement: Network connection (TCP/IP) between the<br />

server <strong>PC</strong> and the connected clients 1)<br />

One license is required for each server.<br />

1) One of the following operating systems is installed<br />

on one WinCC server:<br />

Windows Server 2003, Windows Server 2003 R2 or<br />

Windows Server 2008. Max. 3 clients with Windows XP Professional.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

WinCC Client WinCC Client WinCC Client<br />

HMI Software<br />

SIMATIC WinCC options<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

WinCC/Server<br />

G_<strong>ST</strong><strong>80</strong>_XX_00005<br />

4/89<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC options<br />

WinCC/Server<br />

■ Benefits<br />

Plant-wide scalability from the single-user system to<br />

the client/server solution<br />

Significantly higher quantity framework, relieving the<br />

individual servers and better performance due to distributing<br />

the complete application or tasks over several servers<br />

Low-cost configuration on the client is possible (the minimum<br />

RC license is sufficient)<br />

■ Application<br />

In a complex plant, WinCC can also be configured as a<br />

distributed system according to requirements:<br />

Functional distribution (e.g. message servers, archive<br />

servers, etc.) or<br />

Distribution according to the physical plant structure<br />

(e.g. body-in-white, paintshop, etc.)<br />

4/90<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Function<br />

Each client can access more than one server at a time. Clients<br />

can also be used for configuration on the server.<br />

A configuration of WinCC clients as a central web server – as a<br />

distributed system if required – with an overview of all server<br />

projects in the system is also possible.<br />

Only the smallest runtime license RT128 is required for the<br />

clients, or if configuring is also to be handled on the client, the<br />

smallest complete license RC128 is sufficient. This makes it<br />

possible to configure inexpensive operator and configuration<br />

stations in a network.<br />

■ Ordering data<br />

WinCC/Server<br />

Order No.<br />

for WinCC V6.2 6AV6 371-1CA07-0AX0<br />

for WinCC V7.0 6AV6 371-1CA06-2AX0


■ Overview<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Option for SIMATIC WinCC for operator control and monitoring<br />

of plants via the Internet, in-house intranet or LAN<br />

Configuration from:<br />

- a web server with the SIMATIC WinCC software as a singleuser,<br />

client or server version and a Web client that enables<br />

operator control and monitoring of a current WinCC project<br />

via an Internet browser with ActiveX support. The WinCC<br />

basic system does not have to be installed on the client<br />

computer. It is also possible to use the web client without<br />

Microsoft Internet Explorer.<br />

Licensing:<br />

- A license is required in order to use the web server.<br />

- Licenses are available for access to the web server by 3, 10,<br />

25 or 50 clients.<br />

- Low-cost Web Navigator Diagnostics licenses are available<br />

for remote diagnostics via a number of distributed web<br />

servers with guaranteed access.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<br />

HMI Software<br />

SIMATIC WinCC options<br />

<br />

<br />

WinCC/Web Navigator<br />

<br />

<br />

<br />

<br />

Highlights:<br />

Installation of the web server – in distributed systems – also on<br />

a WinCC Client;<br />

- Access to up to 12 subordinate WinCC stations (servers)<br />

possible<br />

- Web Clients offer common views of data on various WinCC<br />

Servers<br />

- If you are using WinCC/Redundancy, the Web Clients will<br />

also transfer via the subordinate WinCC Servers (requires<br />

WinCC Client running as web server).<br />

- Separating the Web functionality from the WinCC data<br />

servers makes the overall system safer and more scalable in<br />

respect of load. Integrated user management with WinCC:<br />

The configured WinCC operator authorizations are taken into<br />

account on the Web Client.<br />

Access to user archives<br />

VB scripts are supported in the same way as the new objects<br />

and RT functions in WinCC V6<br />

User-friendly services and tools for distributing customized<br />

objects (controls, files) to Web Clients can be supplied for use<br />

as an integration platform. These components can then also<br />

be integrated into cross-web/server navigation.<br />

Distribution of load across a number of web servers in order to<br />

run several hundred Web Clients in a single system; Web<br />

Clients are distributed across web servers automatically.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

<br />

4/91<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC options<br />

WinCC/Web Navigator<br />

■ Benefits<br />

Operator control and monitoring across long distances and on<br />

different platforms (<strong>PC</strong>, local panel, mobile PDA)<br />

Large configurations with up to 50 operator stations<br />

Fast updating rates thanks to event-driven communication<br />

Optimally tailored clients for operating and monitoring,<br />

analysis, service and diagnostics<br />

Acceptance of configuration data for the web, generally<br />

without changes<br />

Minimum maintenance costs thanks to centralized software<br />

administration<br />

High security standards and availability<br />

- Increased security due to separation of WinCC server and<br />

web server (web server in secure environment)<br />

- Support for commonly used security mechanisms (routers,<br />

firewalls, proxy servers)<br />

- Access authorization and user administration<br />

Innovations of V7.0<br />

Version 7 supports Microsoft Internet Explorer Version 8.0,<br />

including tabbed browsing. A new license is not required for<br />

separate tabs.<br />

With the WinCC Web Viewer, the process screens can be<br />

displayed on the Web Client independently of the Internet<br />

Explorer. Settings for the client are made on the client itself.<br />

- Address, user name and password.<br />

- Runtime language, disable keys, hotkey property sheets.<br />

- Start screen, menu and toolbars, Windows attributes.<br />

- Activate monitor keyboard, ,<br />

automatic logout.<br />

The WinCC Web Viewer can also be used in conjunction with<br />

the MS Terminal Service.<br />

From version 7 on, the web navigator can also be operated<br />

in "view only" mode and is thus used as tool for operating<br />

and navigating only via WinCC screens by means of<br />

Internet Explorer.<br />

The cursor for View only mode can be selected according to<br />

individual requirements.<br />

Web server logins and logouts are recorded in the alarm and<br />

audit archive.<br />

There is a gadget available for the Windows 7 operating<br />

system in which selected WinCC process screens can be<br />

displayed. The gadget does not require any additional Web<br />

Navigator license. The Web Navigator server can be selected<br />

direct using the gadget.<br />

Security is increased by adjustable automatic logout. If an<br />

automatic logout is to take place, an absolute or inactive time<br />

period can be set.<br />

Runtime in the web client can be terminated by means of<br />

scripting.<br />

4/92<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Application<br />

Apart from the typical application of the Web Navigator in the<br />

WAN field (Wide Area Network), the Web Navigator can also be<br />

used for extremely cost-effective solutions. This particularly<br />

includes applications that have a widely distributed structure<br />

(water/sewage, oil and gas), or in which there is only sporadic<br />

accessing of process information (buildings management).<br />

The Web Navigator also supports vertical integration, i.e. a<br />

networked IT landscape with company-wide data flow between<br />

the planning and operational levels of a company. The only tool<br />

that is required for direct access to up-to-date process information<br />

is a standard browser.<br />

The web server can have its own direct process connection.<br />

Alternatively, coupling is possible by means of O<strong>PC</strong> or a web<br />

server subordinate to a WinCC client. This not only increases<br />

reliability, but also reduces the data traffic within the system.<br />

In addition to the standard Web navigator license, a so-called<br />

diagnostic client exists which basically has the same functions<br />

but which is particularly suitable for the following applications:<br />

Remote diagnostics/operation by several unmanned WinCC<br />

stations<br />

Central control rooms with multiple web server support<br />

through a single user interface<br />

Power users who require guaranteed access to the server at<br />

any time, regardless of how many users are already logged<br />

on.


■ Design<br />

Licenses for the Web Navigator<br />

The Web Navigator Client software can be installed as many<br />

times as required without the need for a license.<br />

Server-based licensing;<br />

a license is required in order to use the Web Navigator Server.<br />

Licenses are available for simultaneous access to the web<br />

server by 3, 10, 25 or 50 clients.<br />

Diagnostics client licensing;<br />

for optimum-cost access by one or a small number of<br />

Web Navigator Clients to numerous web servers<br />

(e.g., for the purpose of diagnostics). This client license<br />

provides guaranteed access to web servers at any time.<br />

In respect of function there is no difference compared with<br />

regular Web Navigator Clients and the two can be mixed.<br />

Web Navigator Clients can:<br />

access a number of different web servers or<br />

access data on a number of higher-level WinCC stations<br />

simultaneously via a remote web server<br />

On the server side, only one Web Navigator Diagnostics Server<br />

license or, alternatively, one Standard Web Navigator license is<br />

required.<br />

Alternatively, a number of Web Navigator Servers with the same<br />

WinCC project can be combined to create a "server farm". This<br />

means that it is possible for several hundred Web Clients to have<br />

access to the same database. The service ensures that the<br />

clients accessing are distributed evenly across all servers. If a<br />

server fails, the Web Client is automatically forwarded to the next<br />

available server.<br />

In order to use this functionality you will need to install a<br />

Web Load Balancing license on the web servers involved.<br />

Each Load Balance package contains 2 licenses.<br />

An inexpensive expansion option for Web Load Balancing is<br />

available for redundant WinCC stations on which the Web<br />

Navigator is also installed. For this purpose, you need to install<br />

a Web Load Balancing Step Up license on the web servers<br />

involved. Each Step Up package contains 2 licenses.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SIMATIC WinCC options<br />

WinCC/Web Navigator<br />

Thin Client solutions<br />

The Web Navigator can also run under Windows Server 2003 or<br />

Windows Server 2008 terminal services. A Windows Server 2003<br />

or Windows Server 2008 (or higher) operating system is<br />

required. This makes it possible to connect SIMATIC Thin Clients<br />

as visualization stations to WinCC, for example.<br />

For this purpose, the Windows terminal services must be<br />

installed on the <strong>PC</strong> on which the Web Client is installed.<br />

A Windows Server 2003 or Windows Server 2008 (or higher)<br />

operating system is required. Up to 25 Thin Clients can be<br />

connected to one terminal server.<br />

Applications:<br />

Mobile devices<br />

Handhelds<br />

Rugged on-site visualizations<br />

Hybrid configuration<br />

Web Navigator and DataMonitor Clients can be mixed in a single<br />

system.<br />

■ Function<br />

The Web Configurator (Wizard) makes setting up and<br />

configuring a Web Navigator Server very easy.<br />

WinCC process screens to be visualized via the Internet are<br />

created as usual using WinCC Graphics Designer. Under normal<br />

circumstances, the project can be worked on locally without<br />

modification. The Web Publishing Wizard optimizes the screens<br />

for transmission and display on the Internet. A standard browser<br />

is all that is required to display WinCC process screens on the<br />

Web Client. The MS Internet Explorer is used depending on the<br />

Web Navigator version used (tip: start the Internet Explorer in<br />

full-screen mode with the start parameter "-k").<br />

The operator on the Web Client is integrated in the central<br />

WinCC user administration and can operate and monitor the<br />

system according to the configured access rights. The Web<br />

Navigator supports all standard security mechanisms that can<br />

be used for applications on the Internet, e.g. routers, firewalls<br />

and proxy servers.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/93<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC options<br />

WinCC/Web Navigator<br />

■ Ordering data Order No. Order No.<br />

WinCC/Web Navigator<br />

V7.0; for WinCC V7.0,<br />

WinCC V7.0 SP1/SP2/SP3 and<br />

WinCC V7.0 SP1/SP2/SP3 ASIA<br />

Base Pack (3 client licenses) 6AV6 371-1DH07-0AX0<br />

10 client licenses 6AV6 371-1DH07-0BX0<br />

25 client licenses 6AV6 371-1DH07-0CX0<br />

50 client licenses 6AV6 371-1DH07-0DX0<br />

WinCC/Web Navigator Power<br />

Packs V7.0<br />

From 3 to 10 clients 6AV6 371-1DH07-0AB0<br />

From 10 to 25 clients 6AV6 371-1DH07-0BC0<br />

From 25 to 50 clients 6AV6 371-1DH07-0CD0<br />

WinCC/Web Navigator<br />

Diagnostics Client<br />

for WinCC V7.0 6AV6 371-1DH07-0EX0<br />

WinCC/Web Navigator<br />

Diagnostics Server<br />

for WinCC V7.0 6AV6 371-1DH07-0FX0<br />

WinCC/Web Navigator Upgrade<br />

V6.0 to V7.0<br />

For 3 clients 6AV6 371-1DH07-0AX4<br />

For 10 clients 6AV6 371-1DH07-0BX4<br />

For 25 clients 6AV6 371-1DH07-0CX4<br />

For 50 clients 6AV6 371-1DH07-0DX4<br />

V6.2 to V7.0<br />

For 3 clients 6AV6 371-1DH07-0AX3<br />

For 10 clients 6AV6 371-1DH07-0BX3<br />

For 25 clients 6AV6 371-1DH07-0CX3<br />

For 50 clients 6AV6 371-1DH07-0DX3<br />

V6.x to V7.0<br />

For Web Navigator Diagnostics 6AV6 371-1DH07-0EX4<br />

Client<br />

For Web Navigator Diagnostics 6AV6 371-1DH07-0FX4<br />

Server<br />

WinCC / Web Load Balancing<br />

V7.0<br />

Load Balancing 6AV6 371-1DH07-0JX0<br />

Load Balancing Step Up 6AV6 371-1DH07-0FJ0<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

4/94<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

WinCC/Web Navigator<br />

V6.2 SP3; for WinCC V6.2 SP3<br />

Base Pack (3 client licenses) 6AV6 371-1DH06-2AX0<br />

10 client licenses 6AV6 371-1DH06-2BX0<br />

25 client licenses 6AV6 371-1DH06-2CX0<br />

50 client licenses<br />

V6.2 SP3 ASIA;<br />

for WinCC V6.2 SP3 ASIA<br />

6AV6 371-1DH06-2DX0<br />

Base Pack (3 client licenses) 6AV6 371-1DH06-2AV0<br />

10 client licenses 6AV6 371-1DH06-2BV0<br />

25 client licenses 6AV6 371-1DH06-2CV0<br />

50 client licenses<br />

WinCC/Web Navigator<br />

Power Packs<br />

V6.2 (for ASIA versions as well)<br />

6AV6 371-1DH06-2DV0<br />

From 3 to 10 clients 6AV6 371-1DH06-2AB0<br />

From 10 to 25 clients 6AV6 371-1DH06-2BC0<br />

From 25 to 50 clients<br />

WinCC/Web Navigator<br />

Diagnostics Client<br />

6AV6 371-1DH06-2CD0<br />

for WinCC V6.2 SP3 6AV6 371-1DH06-2EX0<br />

for WinCC V6.2 SP3 ASIA<br />

WinCC/Web Navigator<br />

Diagnostics Server<br />

6AV6 371-1DH06-2EV0<br />

for WinCC V6.2 SP3 B 6AV6 371-1DH06-2FX0<br />

for WinCC V6.2 SP3 ASIA<br />

WinCC/Web Navigator Upgrade<br />

V1.x to V6.2 SP3<br />

6AV6 371-1DH06-2FV0<br />

For 3 clients 6AV6 371-1DH06-2AX4<br />

For 10 clients 6AV6 371-1DH06-2BX4<br />

For 25 clients 6AV6 371-1DH06-2CX4<br />

For 50 clients<br />

V6.x to V6.2 SP3<br />

6AV6 371-1DH06-2DX4<br />

For 3, 10, 25, 50 clients 1) 6AV6 371-1DH06-2XX3<br />

For Web Navigator Diagnostics<br />

Client<br />

6AV6 371-1DH06-2EX3<br />

For Web Navigator Diagnostics<br />

Server<br />

V6.x ASIA to V6.2 SP3 ASIA<br />

6AV6 371-1DH06-2FX3<br />

For 3, 10, 25, 50 clients 1) WinCC/Web Load Balancing<br />

V6.2 SP3<br />

6AV6 371-1DH06-2XV3<br />

Web Load Balancing<br />

(2 licenses)<br />

6AV6 371-1DH06-2JX0<br />

Web Load Balancing Step Up<br />

(2 licenses)<br />

6AV6 371-1DH06-2FJ0<br />

1) Including upgrade for diagnostics client, diagnostics server,<br />

Web Load Balancing and Web Load Balancing Step Up.


■ More information<br />

System requirements – web server<br />

For WinCC/Web Navigator V7.0<br />

Windows 7 (32-bit) Business, Enterprise and Ultimate<br />

(max. 3 clients)<br />

Windows XP Professional Service Pack 3 (max. 3 clients)<br />

Windows Server 2003 SP2 and Windows Server 2003 R2 SP2<br />

Windows Server 2008 SP2<br />

Internet Explorer V6.0 SP1 or SP2 as well as Internet<br />

Explorer V7.0.<br />

Microsoft SQL Server 2005 SP2 (scope of supply of WinCC)<br />

WinCC Basic System V7.0 SP2<br />

For WinCC/Web Navigator V6.2 SP3<br />

Windows 2000 Professional Service Pack 4 (max. 3 clients)<br />

Windows XP Professional or Service Pack 3 (max. 3 clients)<br />

Windows Server 2003 SP2 or Windows Server 2003 R2 SP2<br />

Internet Explorer 6.0 SP1, SP2 or 7.0 (without multitabbing)<br />

Microsoft SQL Server 2005 SP1 (scope of supply of WinCC)<br />

WinCC basic system V6.2 SP3<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SIMATIC WinCC options<br />

WinCC/Web Navigator<br />

System requirements – web client<br />

For WinCC/Web Navigator V7.0<br />

Internet Explorer V6.0 SP1 or SP2 as well as Internet<br />

Explorer V7.0<br />

For WinCC/Web Navigator V6.2 SP3<br />

Internet Explorer 6.0 SP1, SP2 or 7.0 (without multitabbing)<br />

WinCC Web Navigator V6.2 SP3 ASIA<br />

(requires SIMATIC WinCC V6.2 SP3 ASIA)<br />

The functions included in this version differ from the standard<br />

version of WinCC/Web Navigator V6.2 SP3 as follows:<br />

This version does not allow an Asian Web Navigator client to<br />

access a non-Asian server and vice versa.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/95<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC options<br />

WinCC/TeleControl<br />

■ Overview<br />

WinCC/TeleControl for WinCC V7.0 SP2 supports the connection<br />

to outlying stations (Remote Terminal Units = RTUs) via<br />

telecontrol protocols.<br />

■ Benefits<br />

WinCC/TeleControl for WinCC V7.0 SP2 cannot only integrate<br />

newly configured RTUs, it can also integrate units which already<br />

exist in outlying areas by means of DNP3 or IEC 870-5-101/104<br />

drivers.<br />

For communication with the outstations, WinCC/TeleControl for<br />

WinCC V7.0 SP2 uses the SINAUT <strong>ST</strong>7 and DNP3 protocols<br />

(both via serial and TCP/IP communication connections) as well<br />

as IEC 870-5-101 (serial) and IEC 870-5-104 (Ethernet TCP/IP).<br />

The serial RTU link is possible via the following components,<br />

which can be connected directly via WinCC (single station or<br />

server):<br />

SINAUT TIM communication modules (SINAUT <strong>ST</strong>7<br />

telecontrol protocol)<br />

TCP/IP serial converter (telecontrol protocols DNP3, Modbus<br />

(not released for WinCC TC), IEC 870-5-101)<br />

Equipment from MOXA or Lantronix, for example, can be used<br />

as TCP/IP serial converters.<br />

By means of Ethernet TCP/IP, the RTUs can be connected<br />

directly or via TCP/IP WAN routers to the SIMATIC WinCC system<br />

bus (SINAUT <strong>ST</strong>7, DNP3, IEC 870-5-104 telecontrol protocols).<br />

When using the SINAUT <strong>ST</strong>7 telecontrol protocol, the<br />

SINAUT TIM communication module can be used in addition to<br />

the TCP/IP WAN router or as an alternative.<br />

4/96<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Application<br />

Telecontrol communication over the wide area network is largely<br />

determined by the communication infrastructure which already<br />

exists. Various transmission media such as dedicated line,<br />

analog or digital telephone networks, wireless networks (GSM or<br />

private), DSL or GPRS can also be combined with each other.<br />

SINAUT <strong>ST</strong>7 telecontrol protocol<br />

Detailed information for implementing telecontrol applications<br />

with the SINAUT <strong>ST</strong> 7 telecontrol protocol via the Industry Mall.<br />

IEC 870-5-101/-104 telecontrol protocols<br />

Detailed information for implementing telecontrol applications<br />

with the IEC 870-5-101/-104 telecontrol protocols via the<br />

Industry Mall.<br />

DNP3 telecontrol protocol<br />

WinCC/TeleControl for WinCC V7.0 SP2 also supports the<br />

DNP3 telecontrol protocol. Widely distributed outstations (RTUs)<br />

can be controlled and monitored with the DNP3 telecontrol<br />

protocol via serial or Ethernet TCP/IP communication links<br />

by means of the telecontrol center in SIMATIC WinCC.<br />

The control center integrated with SIMATIC WinCC TeleControl<br />

into the SCADA system is the master during telecontrol<br />

communication. The slaves are represented by the outstations.<br />

SIMATIC S7-300/S7-300F and S7-400/S7-400F/S7-400H/<br />

S7-400FH controllers as well as third-party RTUs can be used as<br />

outstations.<br />

Further hardware and software components round off the range<br />

of products:<br />

TIM communication modules<br />

TCP/IP converters – serial and MD modem modules<br />

GSM/GPRS components<br />

TCP/IP routers and switches<br />

SCALANCE S612 and S613 security modules<br />

Dedicated-line accessories<br />

Cables<br />

Engineering package for configuration of DNP3 data objects,<br />

stations, networks and connections as well as for diagnostics<br />

In order to implement telecontrol networks, basic topologies<br />

including point-to-point, multi-point, star and ring can be<br />

configured using classic or TCP/IP-based media. These can be<br />

combined flexibly dependent from existing infrastructure.<br />

Classic WAN media:<br />

Dedicated line via modem, e.g. SINAUT MD2<br />

Private wireless networks<br />

Analog telephone network<br />

Digital ISDN network<br />

Mobile radio network GSM<br />

TCP/IP-based WAN media:<br />

Ethernet networks, e.g. SCALANCE X with fiber-optic cables<br />

Industrial Wireless LAN with SCALANCE W<br />

Public networks and the Internet using DSL and/or GPRS


■ Function<br />

Special characteristics of DNP3 communication<br />

Change-driven data transmission<br />

- Change-driven transmission of process data between<br />

RTU and control center<br />

- Signaling of RTU, control center or connection failure<br />

- Automatic data updating for all communication partners<br />

involved following troubleshooting and following the startup<br />

of the RTU or control center<br />

Chronological processing of process data<br />

- Time tagging of all data frames at the place of origin allows<br />

process data to be archived by the process control system<br />

in the correct chronological order<br />

- The time of the DNP3 stations in the WAN can be<br />

synchronized via SIMATIC WinCC (including summertime/<br />

wintertime switchover)<br />

Local data storage<br />

- The TIM communication module can temporarily store<br />

(for several hours or even days) message frames should the<br />

connection or the communication partner fail<br />

- Intermediate storage of message frames of lower priority in<br />

the case of priority-controlled data transmission (with dial-up<br />

networks or quantity-dependent data transmission costs)<br />

Operating modes<br />

The DNP3 telecontrol protocol supports the following operating<br />

modes:<br />

Polling<br />

Polling with time slot procedure<br />

Multi-master polling with time slot procedure<br />

Spontaneous mode in dial-up networks<br />

Spontaneous mode in the TCP/IP-based WAN<br />

■ Integration<br />

Integration of WinCC/ TeleControl for WinCC V7.0 SP2 into the<br />

WinCC SCADA system offers particular advantages for the water<br />

and waste water sectors, as well as oil and gas sectors,<br />

especially in the case of the following types of plant:<br />

Freshwater treatment and distribution<br />

Wastewater treatment plants<br />

Oil and gas pipelines or water pipes<br />

Oil and gas drilling fields and the associated treatment plants<br />

In these types of plant, remote outstations such as pumping<br />

stations, valve stations or automated stations for wellheads must<br />

be integrated.<br />

Through the support of communication protocols for RTUs such<br />

as SINAUT <strong>ST</strong>7, WinCC/ TeleControl for WinCC V7.0 SP2<br />

supports the following advanced communication concepts:<br />

Reduction in the transferred data volume by means of<br />

event-controlled communication mechanisms for alarm and<br />

measured value information.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SIMATIC WinCC options<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

WinCC/TeleControl<br />

Time-synchronization of RTUs and correct time stamping of all<br />

data in the RTU.<br />

Tolerance of lower bandwidth, high latency or lack of reliability<br />

of communication lines<br />

Prevention of data loss due to communications failure through<br />

data backup in the RTU<br />

Support of communication media with serial interface<br />

(dedicated lines, dial-up connections over analog telephone<br />

lines and ISDN lines), various radio devices (standard, spread<br />

spectrum modulation), microwave and GSM<br />

Support for TCP/IP-based WANs (Wide Area Networks) such<br />

as DSL, GPRS or Ethernet radio networks<br />

Support for redundant communication connections<br />

Expanded communication diagnostics functions for<br />

RTU communication links<br />

Remote programming of RTUs<br />

Support for different communication topologies – Point-topoint,<br />

multidrop (multistation mode) and hierarchic network<br />

structures<br />

High quality server redundancy scheme without data loss in<br />

the case of server failure<br />

Through the support of communication protocols for RTUs<br />

such as IEC 60870-5 and DNP3, SIMATIC TELECONTROL for<br />

WinCC V7.0 SP2 supports the following advanced communication<br />

concepts:<br />

Reduction in the transferred data volume by means of<br />

event-controlled communication mechanisms for alarm and<br />

measured value information.<br />

Time-synchronization of RTUs and correct time stamping of all<br />

data in the RTU.<br />

Tolerance of lower bandwidth, high latency or lack of reliability<br />

of communication lines<br />

Prevention of data loss due to communications failure through<br />

data backup in the RTU (not all non-<strong>Siemens</strong> RTUs support<br />

this)<br />

Support of communication media with serial interface<br />

(dedicated lines, dial-up connections over analog telephone<br />

lines and ISDN lines), various radio devices (standard, spread<br />

spectrum modulation), microwave and GSM<br />

Support for TCP/IP-based WANs (Wide Area Networks) such<br />

as DSL, GPRS or Ethernet radio networks<br />

Support for redundant communication connections<br />

Expanded communication diagnostics functions for<br />

RTU communication links<br />

Remote programming of RTUs<br />

Support for different communication topologies – Point-topoint,<br />

multidrop (multistation mode) and hierarchic network<br />

structures<br />

High quality server redundancy scheme without data loss in<br />

the case of server failure<br />

4/97<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC options<br />

WinCC/TeleControl<br />

■ Integration (continued)<br />

Outstations/remote terminal units<br />

WinCC/ TeleControl for WinCC V7.0 SP2 supports the following<br />

preferred outstations for local distributed automation:<br />

Controller integrated into ET 200S (IEC 870-5-101/104<br />

telecontrol protocols); for cost-sensitive applications,<br />

up to approx. 30 I/O signals or approx. 200 data points<br />

S7-300/S7-300F controller (SINAUT <strong>ST</strong>7, DNP3,<br />

IEC 870-5-101/104 telecontrol protocols);<br />

for extremely flexible configuration,<br />

up to 100 I/O signals or approx. 2000 data points<br />

1) Data buffering is limited to two SIMATIC S7 data blocks.<br />

Depending on the SIMATIC CPU, this corresponds to<br />

approx. <strong>80</strong>0 to 3200 buffered frames.<br />

4/98<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

S7-400/S7-400F controller (SINAUT <strong>ST</strong>7, DNP3,<br />

IEC 870-5-101/104 telecontrol protocols);<br />

up to 500 I/O signals or approx. 5000 data points<br />

S7-400/S7-400F redundant controller (IEC 870-5-101/104 and<br />

DNP3 telecontrol protocols);<br />

up to 500 I/O signals or approx. 5000 data points<br />

Third-party station with the IEC 870-5-101/104 and<br />

DNP3 telecontrol protocols (depending on type of station)<br />

The following table provides an overview of the current options<br />

for connecting to these outstations:<br />

Spectrum of outstations and integration versions<br />

Telecontrol protocol SINAUT <strong>ST</strong> 7 DNP3 IEC 870-5-01 IEC 870-5-04<br />

Type of communication Serial Ethernet TCP/IP Serial Ethernet TCP/<br />

IP<br />

Serial Ethernet TCP/IP<br />

Interface TIM 4R-IE TCP/IP WAN TCP/IP serial TCP/IP WAN TCP/IP serial TCP/IP WAN<br />

router or/and TIM<br />

4R-IE<br />

converter router<br />

converter router<br />

RTU/interface ET 200S with - - - - IM 151-7 CPU or IM 151-8 PN/DP<br />

integr. CPU<br />

IM 151-8 PN/DP CPU +<br />

(corre-<br />

CPU<br />

SIPLUS RIC<br />

sponding to<br />

as well as library<br />

S7-314)<br />

1 SI module +<br />

SIPLUS RIC<br />

library<br />

S7-300/ TIM 3V-IE TIM 3V-IE TIM 3V-IE DNP3 TIM 3V-IE CP 341 + CP 343 +<br />

S7-300F<br />

DNP3<br />

SIPLUS RIC IEC on S7 or<br />

library<br />

integr. PN<br />

interface +<br />

SIPLUS RIC<br />

library<br />

S7-400/ TIM 4R-IE TIM 4R-IE TIM 4R-IE DNP3 TIM 4R-IE CP 441 + CP 443 +<br />

S7-400F<br />

DNP3<br />

SIPLUS RIC SIPLUS RIC<br />

library<br />

library or integr.<br />

PN interface +<br />

SIPLUS RIC<br />

library<br />

S7-400H/ - - TIM 4R-IE DNP3 TIM 4R-IE ET 200M + CP 443 +<br />

S7-400FH<br />

DNP3<br />

2 x CP 341 + SIPLUS RIC<br />

SIPLUS RIC<br />

library<br />

library<br />

Third-party<br />

station<br />

- - Depends on type of station Depends on type of station<br />

Dial-up lines<br />

Dedicated line and radio<br />

networks<br />

Master/slave<br />

- - - -<br />

Peer-to-peer<br />

Mesh networks<br />

Time tagging in RTU<br />

RTU time synchronization<br />

- -<br />

Data buffering in RTU 1) 1)<br />

Routing with SIMATIC PDM - - -<br />

International standard - -


■ Ordering data Order No. Order No.<br />

SIMATIC TeleControl 7.0 SP2<br />

for WinCC Basic Engineering<br />

Software package with<br />

SIMATIC Telecontrol for<br />

WinCC 7.0 SP2 Engineering<br />

Software, 2 languages (English,<br />

German), executable with<br />

Windows XP Professional/Server<br />

2003, Floating License for one<br />

user; electronic documentation<br />

on CD/DVD, 2 languages<br />

(English, German)<br />

Type of delivery:<br />

License key memory stick,<br />

Certificate of License incl. terms<br />

and conditions, SIMATIC WinCC<br />

Data Medium Package V7.0 +<br />

SP2 and CD "WinCC TeleControl<br />

Option V7.0 + SP2"<br />

SIMATIC TeleControl 7.0 SP2<br />

for Server Runtime (6 stations)<br />

Software package with<br />

SIMATIC Telecontrol for WinCC<br />

7.0 SP2 Runtime Software,<br />

2 languages (English, German),<br />

executable with Windows Server<br />

2003, Single License for one user;<br />

electronic documentation<br />

on CD/DVD, 2 languages<br />

(English, German)<br />

Type of delivery:<br />

License key memory stick,<br />

Certificate of License incl. terms<br />

and conditions, SIMATIC WinCC<br />

Data Medium Package V7.0 +<br />

SP2 and CD "WinCC TeleControl<br />

Option V7.0 + SP2"<br />

SIMATIC TeleControl 7.0 SP2<br />

for Server Runtime (12 stations)<br />

Software package with<br />

SIMATIC Telecontrol for WinCC<br />

7.0 SP2 Runtime Software,<br />

2 languages (English, German),<br />

executable with Windows Server<br />

2003, Single License for one user;<br />

electronic documentation<br />

on CD/DVD, 2 languages<br />

(English, German)<br />

Type of delivery:<br />

License key memory stick,<br />

Certificate of License incl. terms<br />

and conditions, SIMATIC WinCC<br />

Data Medium Package V7.0 +<br />

SP2 and CD "WinCC TeleControl<br />

Option V7.0 + SP2"<br />

SIMATIC TeleControl 7.0 SP2<br />

for Server Runtime<br />

(256 stations)<br />

Software package with<br />

SIMATIC Telecontrol for<br />

WinCC 7.0 SP2 Runtime Software,<br />

2 languages (English, German),<br />

executable with Windows Server<br />

2003, Single License for one user;<br />

electronic documentation<br />

on CD/DVD, 2 languages<br />

(English, German)<br />

Type of delivery:<br />

License key memory stick,<br />

Certificate of License incl. terms<br />

and conditions, SIMATIC WinCC<br />

Data Medium Package V7.0 +<br />

SP2 and CD "WinCC TeleControl<br />

Option V7.0 + SP2"<br />

6DL5 000-7AA07-0XA5<br />

6DL5 002-7AA07-0XA0<br />

6DL5 002-7AB07-0XA0<br />

6DL5 002-7AE07-0XA0<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Driver software for telecontrol<br />

protocols<br />

TeleControl SINAUT Driver<br />

HMI Software<br />

SIMATIC WinCC options<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

WinCC/TeleControl<br />

D 6DL5 101-8AX00-0XB0<br />

Runtime license for one<br />

WinCC Single Station or one<br />

WinCC server,<br />

Single License for 1 installation<br />

Requirement:<br />

Software<br />

SIMATIC TELECONTROL 7.0 SP2<br />

for WinCC Server Runtime<br />

(6, 12, 256 stations)<br />

Type of delivery:<br />

License key memory stick,<br />

Certificate of License incl. terms<br />

and conditions<br />

TeleControl DNP3 Driver<br />

Runtime license for<br />

one WinCC Single Station or<br />

one WinCC server,<br />

Single License for 1 installation<br />

Requirement:<br />

Software<br />

SIMATIC TELECONTROL 7.0 SP2<br />

for WinCC Server Runtime<br />

(6, 12, 256 stations)<br />

Type of delivery:<br />

License key memory stick,<br />

Certificate of License incl. terms<br />

and conditions<br />

D 6DL5 101-8EX00-0XB0<br />

TeleControl IEC 870-5-101/-104 D<br />

Driver<br />

Runtime license for<br />

one WinCC Single Station or<br />

one WinCC server,<br />

Single License for 1 installation<br />

Requirement:<br />

Software<br />

SIMATIC TELECONTROL 7.0 SP2<br />

for WinCC Server Runtime<br />

(6, 12, 256 stations)<br />

Type of delivery:<br />

License key memory stick,<br />

Certificate of License incl. terms<br />

and conditions<br />

6DL5 101-8CX00-0XB0<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

■ More information<br />

For an overview of the complete performance spectrum on the<br />

Internet, visit:<br />

Service & Support:<br />

www.siemens.com/automation/csi_en_WW/service<br />

Technical Support (hotline) for Automation & Drives:<br />

www.siemens.com/automation/csi_en_WW/support_request<br />

4/99<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC options<br />

WinCC/Central Archive Server (CAS)<br />

■ Overview<br />

Central data management, reliable, high-performance archiving<br />

and central backup mechanisms form the basis of a Process<br />

Historian solution: Integration in the SCADA world, data interfaces<br />

for access to archived data and analysis functions are the<br />

component parts.<br />

The option CAS was designed for this purpose and is used to<br />

export the archived data of all servers in the system to a<br />

computer and manage it. Integration of CAS in the WinCC world<br />

means that the data remain available for the WinCC clients as<br />

well as for the WinCC standard interfaces.<br />

WinCC/CAS contains all licenses for the central archive server<br />

including 1500 archive tags. The number of archive tags can be<br />

increased to 120000 using Power Packs or further WinCC<br />

archives.<br />

■ Benefits<br />

Central data management of all archived alarms and process<br />

values<br />

Integrated back-up system for the archive data<br />

Transparent access to the data from all WinCC clients and<br />

over the open interfaces<br />

Integrated Web viewer for analyzing data<br />

4/100<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Function<br />

Both the process value archive and alarm log are created on the<br />

separate WinCC servers and transferred to CAS when individual<br />

database segments have been closed.<br />

With "Store&Forward", when the network is interrupted between<br />

the WinCC server and CAS, data will be reliably transferred as<br />

soon as the network is operating again.<br />

Data access is transparent for display and analysis and is still<br />

possible through the standard WinCC clients. For the clients, it<br />

is of no consequence whether the data are on the WinCC server<br />

or already on CAS. Data saved in CAS can also be viewed using<br />

the Web viewer included in the package.<br />

The data of the distributed WinCC system can also be accessed<br />

through the familiar interfaces (O<strong>PC</strong> DA, O<strong>PC</strong> A&E, O<strong>PC</strong> HDA<br />

and Ole-DB) with the help of the Connectivity Pack or the<br />

Connectivity Station. In this manner, the data saved in CAS can<br />

be efficiently transferred to higher-level systems or used for the<br />

purposes of analysis.<br />

■ Ordering data Order No.<br />

WinCC/CAS V7.0 SP2 basic<br />

packages<br />

WinCC/CAS V7.0 SP2 6AV6 371-1DQ17-0XX0<br />

WinCC/CAS V7.0 SP2 ASIA 6AV6 371-1DQ17-0XV0<br />

WinCC/CAS upgrade<br />

V6.2 to V7.0 SP2 6AV6 371-1DQ17-0XX3<br />

V6.2 ASIA to V7.0 SP2 ASIA 6AV6 371-1DQ17-0XV3<br />

WinCC/CAS V6.2 SP3 basic<br />

packages<br />

WinCC/CAS V6.2 SP3 6AV6 371-1DQ16-2XX0<br />

WinCC/CAS V6.2 SP3 ASIA 6AV6 371-1DQ16-2XV0<br />

Note:<br />

Standard Archive Power Packs (see WinCC ordering data) can<br />

also be used for WinCC/Central Archive Server (CAS)


■ Overview<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00082<br />

G_<strong>ST</strong><strong>80</strong>_XX_00083<br />

G_<strong>ST</strong><strong>80</strong>_XX_00084<br />

HMI Software<br />

SIMATIC WinCC options<br />

WinCC/Redundancy<br />

Option for SIMATIC WinCC, supporting the parallel operation<br />

of two interfaced WinCC single-user systems or process data<br />

servers for mutual monitoring.<br />

If one of the two server <strong>PC</strong>s or one of the two WinCC stations<br />

fails, the second one will take over control of the entire system.<br />

Once the failed server or station is restored to operation, the<br />

content of all the message and process value archives are<br />

copied to it.<br />

One WinCC/Redundancy package is required for each<br />

redundant pair of servers.<br />

■ Benefits<br />

Increased system availability with continuous data integrity<br />

Automatic changeover of client in the event of failure of a<br />

server or failure of the communication to a server<br />

Continuous operator control and visualization thanks to<br />

automatic client changeover to the intact server<br />

Automatic updating of all archives in the background after<br />

rectification of the fault<br />

■ Function<br />

Normally, two WinCC stations or process data servers run in<br />

parallel. Each station has its own process connection and its<br />

own data archives. WinCC/Redundancy ensures automatic<br />

matching of system and user archive data.<br />

If one of the two server computers or WinCC stations fails, the<br />

second will take over the archiving of messages and process<br />

data, thereby ensuring seamless data integrity. In client/server<br />

mode, the clients are automatically switched from the failed<br />

server to the redundant partner. This ensures continuous plant<br />

visualization and operation on every operator station.<br />

When the failed partner resumes operation, all process values,<br />

messages and data archived during the fail period are automatically<br />

matched with the partner. This process runs in the<br />

background and does not affect plant continuity. Once this is<br />

complete, two equivalent servers/stations will be available<br />

again.<br />

Communication with the SIMATIC S7 PLC can also be<br />

configured with redundancy (an H Series SIMATIC S7 is<br />

required) by plugging in two communication modules and<br />

configuring two communication paths (S7-REDCONNECT<br />

software package). The use of failsafe H Series SIMATIC S7<br />

PLCs can, if required, further increase availability at control level.<br />

■ Ordering data Order No.<br />

WinCC/Redundancy<br />

for WinCC V7.0 6AV6 371-1CF07-0AX0<br />

for WinCC V6.2 6AV6 371-1CF06-2AX0<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/101<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC options<br />

SIMATIC Maintenance Station<br />

■ Overview<br />

System-integrated plant asset management system<br />

Automatic generation of a maintenance view in WinCC from<br />

the <strong>ST</strong>EP 7 hardware configuration<br />

Plant-wide visualization of all automation components from the<br />

management level to the field level in ready linked,<br />

hierarchically arranged WinCC displays<br />

Mapping of central and distributed SIMATIC S7 components,<br />

PROFIBUS and PROFINET networks as well as associated<br />

bus nodes<br />

Ethernet network components and industrial <strong>PC</strong>s can be<br />

integrated through SIMATIC NET SNMP O<strong>PC</strong> Server<br />

Display of device status with group status generation in<br />

overview and detail displays<br />

The device statuses "Maintenance required" and<br />

"Maintenance request" are supported for status-based<br />

maintenance<br />

Provision of uniform faceplates showing detailed information<br />

for all components displayed<br />

Display of the device identification data (electronic rating<br />

plate)<br />

Integrated display of the status of the request<br />

4/102<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Reducing downtimes:<br />

- problems in the plant are detected sooner due to the uniform<br />

presentation and clear overview of all information that is<br />

important for maintenance.<br />

Avoiding downtimes:<br />

- support of condition-based maintenance.<br />

Reduced maintenance costs:<br />

- optimization of the flow of information between production<br />

and maintenance by submitting maintenance requests and<br />

presenting the status of requests.<br />

Transparency and traceability:<br />

- all procedures are based on messages and can therefore be<br />

archived and traced.<br />

- a comprehensive database is generated that can be<br />

analyzed with WinCC functions or external tools.<br />

Scalability:<br />

- support of WinCC single-user stations and client/server<br />

configurations.<br />

- the SIMATIC Maintenance Station can be added to an<br />

existing WinCC project.<br />

Consistency:<br />

- The maintenance view is generated from the control project<br />

and is consistent with it.<br />

Flexibility in selection of devices:<br />

- use of the PROFIBUS and PROFINET standards for device<br />

interfacing.<br />

- an additional proxy concept allows devices to be displayed<br />

that are not included in the <strong>ST</strong>EP 7 hardware configuration or<br />

that do not support the standard diagnostics of PROFIBUS/<br />

PROFINET.<br />

■ Application<br />

The SIMATIC Maintenance Station is a tool for the diagnosis and<br />

maintenance of machines and plants. This is an option package<br />

for <strong>ST</strong>EP 7 V5.4 and WinCC V6.2 or V7.0 that generates a WinCC<br />

maintenance view for a <strong>ST</strong>EP 7 project/multiproject.


■ Design<br />

The SIMATIC Maintenance Station is available in various<br />

different packages:<br />

Basic package:<br />

Contains all the tools needed to configure a Maintenance<br />

Station and a license for the display of 100 devices.<br />

Power Packs:<br />

For larger quantities, Power Packs are available with licenses<br />

for 100, 500 or 1000 devices. These can be added to the<br />

existing licenses and can be combined as required.<br />

In this context, devices can be:<br />

AS systems<br />

Distributed devices (PROFIBUS / PROFINET)<br />

<strong>PC</strong>s<br />

Network components<br />

Asset proxies<br />

Requirements for configuring a<br />

SIMATIC Maintenance Station:<br />

<strong>ST</strong>EP 7 license (V5.4 upwards)<br />

WinCC RC license (V6.2 or V7.0)<br />

The SIMATIC NET licenses required for the plant configuration<br />

Requirements for operation of a<br />

SIMATIC Maintenance Station:<br />

The WinCC licenses (V6.2 or V7.0) complying with the plant<br />

configuration<br />

■ Function<br />

Hierarchic visualization of plant components in WinCC<br />

Generation of a WinCC picture tree for hierarchic display of<br />

the plant components.<br />

Automatic creation and linking of displays, equipment<br />

symbols, status indicators, faceplates and the required<br />

variables.<br />

Presentation of the detailed data in faceplates with selectable<br />

views.<br />

Easy navigation in the plant using<br />

the WinCC Picture Tree Manager.<br />

Generated pictures can be enhanced using<br />

the WinCC Graphic Designer.<br />

Switchover between a WinCC SCADA project and the picture<br />

tree of the SIMATIC Maintenance Station can be configured<br />

using standard WinCC functions.<br />

Display of the current status of the plant and its components<br />

Clearly understandable status displays through the use of<br />

uniform symbols.<br />

Display of no-fault status, fault, maintenance requirement and<br />

maintenance request<br />

Display of status of request for submitted repair requests.<br />

Display of order status.<br />

Display of the alarm status of the components.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SIMATIC WinCC options<br />

SIMATIC Maintenance Station<br />

Display of the identification data of the plant components<br />

Display of the identification data available for a device in the<br />

faceplate for the device.<br />

Automatic loading of the data available in the configuration<br />

into the maintenance station.<br />

Reading of the "Identification & Maintenance functions<br />

(I&M 1) )" in accordance with the PROFIBUS International<br />

specification.<br />

Export 2) of I&M data for all devices in the form of an XML file.<br />

Displaying alarms<br />

Loading of system error messages from <strong>ST</strong>EP 7.<br />

Provides the messages in 5 languages 3) , translation into<br />

additional languages is possible in <strong>ST</strong>EP 7.<br />

Display of the most recent message in a message line.<br />

Presentation of the active/archived messages of the selected<br />

device in the faceplate.<br />

Calling the <strong>ST</strong>EP 7 hardware configuration<br />

The <strong>ST</strong>EP 7 hardware configuration can be opened for a<br />

selected device using a button in the faceplate. <strong>ST</strong>EP 7 and<br />

the project must be installed on the maintenance station for<br />

this purpose.<br />

1) The Maintenance Station 2007 supports reading of I&M data for<br />

PROFIBUS devices with C1 channel access.<br />

2) The I&M data loaded from the configuration are exported.<br />

3) For <strong>Siemens</strong> components that are included in the <strong>ST</strong>EP 7 hardware<br />

catalog.<br />

In the case of components that are integrated in <strong>ST</strong>EP 7 using GSD<br />

files, the GSD files must support the relevant languages.<br />

■ Technical specifications<br />

Hardware requirements<br />

System Clock<br />

frequency<br />

Main<br />

memory<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Free hard<br />

disk space<br />

Engineering station 2.8 GHz 1 GB 15 GB<br />

Maintenance Station<br />

Stand-alone /<br />

WinCC-Station "Singleuser<br />

Workstation"<br />

2.8 GHz 1 GB 15 GB<br />

Maintenance Station<br />

Server /<br />

WinCC Server<br />

2.8 GHz 1 GB 15 GB<br />

Maintenance Station<br />

Client /<br />

WinCC Client<br />

2.8 GHz 512 MB 3 GB<br />

Software requirements<br />

System Operating system<br />

Engineering station "ES" Windows XP Professional SP2<br />

Windows Server 2003 SP1<br />

Maintenance Station Stand-alone / Windows XP Professional SP2<br />

WinCC-Station<br />

"Single-user Workstation"<br />

Windows Server 2003 SP1<br />

ES with Maintenance Station Windows XP Professional SP2<br />

Stand-alone<br />

Windows Server 2003 SP1<br />

Maintenance Station Server /<br />

WinCC Server<br />

Windows Server 2003 SP1<br />

Maintenance Station Client / Windows XP Professional SP2<br />

WinCC Client<br />

Windows Server 2003 SP1<br />

4/103<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC options<br />

SIMATIC Maintenance Station<br />

■ Technical specifications (continued)<br />

Requirements for the integration of devices<br />

Type<br />

SIMATIC S7<br />

controllers / I/O<br />

Integration Comment<br />

S7-300 1) Yes<br />

S7-400 Yes<br />

WinAC Yes<br />

Distributed devices<br />

ET 200 Yes PROFIBUS DP and<br />

PROFINET IO<br />

according to <strong>ST</strong>EP 7<br />

hardware catalog<br />

PROFIBUS standard Yes Integration using a<br />

slaves<br />

GSD file<br />

PROFINET standard<br />

devices<br />

Network components<br />

Ethernet network<br />

components<br />

PROFINET network<br />

components<br />

PROFIBUS diagnostic<br />

repeater<br />

Personal Computer<br />

1) With S7-300, PROFIBUS/PROFINET systems are supported if they are<br />

connected to the internal CPU interfaces<br />

4/104<br />

Yes Integration using a<br />

GSD file<br />

Yes SIMATIC NET SNMP<br />

O<strong>PC</strong> Server and MIB<br />

also required<br />

Yes<br />

Yes<br />

<strong>PC</strong>/Industrial <strong>PC</strong><br />

Drives<br />

Yes SIMATIC NET SNMP<br />

O<strong>PC</strong> Server also<br />

required<br />

Drives with PROFIBUS<br />

connection<br />

Drives with PROFINET<br />

connection<br />

Accessory devices<br />

Devices not configured<br />

in <strong>ST</strong>EP 7 Hardware<br />

Config<br />

Yes For integrating<br />

devices designed to<br />

the PROFIDRIVE<br />

profile, Drive ES<br />

SIMATIC (V5.4 SP1 or<br />

higher) is required<br />

Yes For integrating<br />

devices designed to<br />

the PROFIDRIVE<br />

profile, Drive ES<br />

SIMATIC (V5.4 SP1 or<br />

higher) is required<br />

Yes Integrated via<br />

function block (asset<br />

proxy)<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Ordering data<br />

SIMATIC Maintenance Station<br />

2007<br />

Software for implementation of a<br />

plant-oriented asset management<br />

system<br />

Can be used with <strong>ST</strong>EP 7 V5.4 or<br />

higher and WinCC V6.2<br />

Order No.<br />

Basic package<br />

with engineering software<br />

(Floating License) and Runtime<br />

License for 100 devices<br />

D 6ES7 840-0WD00-0YA0<br />

Power Pack 100<br />

Runtime License for<br />

100 additional devices<br />

D 6ES7 840-0WD10-0YD0<br />

Power Pack 500<br />

Runtime License for<br />

500 additional devices<br />

D 6ES7 840-0WD20-0YD0<br />

Power Pack 1000<br />

Runtime License for<br />

1000 additional devices<br />

D 6ES7 840-0WD30-0YD0<br />

Basic demo package 2007<br />

SIMATIC Maintenance Station<br />

2009<br />

Can be used with <strong>ST</strong>EP 7 V5.4 or<br />

higher and WinCC V7<br />

D 6ES7 840-0WD00-0YA7<br />

Basic package<br />

with engineering software<br />

(Floating License) and Runtime<br />

License for 100 devices<br />

D 6ES7 840-0WD01-0YA0<br />

Power Pack 100<br />

Runtime License for<br />

100 additional devices<br />

D 6ES7 840-0WD11-0YD0<br />

Power Pack 500<br />

Runtime License for<br />

500 additional devices<br />

D 6ES7 840-0WD21-0YD0<br />

Power Pack 1000<br />

Runtime License for<br />

1000 additional devices<br />

D 6ES7 840-0WD31-0YD0<br />

Basic demo package 2009 D 6ES7 840-0WD01-0YA7<br />

Upgrade from SIMATIC<br />

Maintenance Station 2007 to<br />

SIMATIC Maintenance Station<br />

2009<br />

D 6ES7 840-0WD01-0YE0<br />

D: Subject to export regulations: AL: N and ECCN: 5D992


■ Overview<br />

Precise and rapid process fault diagnostics in plants and<br />

machines for SIMATIC S7 and SIMATIC HMI<br />

Standardized diagnostics concept for various SIMATIC<br />

components<br />

No further configuration for diagnostics functionality<br />

Reduces PLC memory and processor usage<br />

Note:<br />

<br />

For further information see "SIMATIC ProAgent process<br />

diagnostics software"<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<br />

HMI Software<br />

SIMATIC WinCC options<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

WinCC/ProAgent<br />

■ Ordering data Order No.<br />

SIMATIC WinCC/ProAgent<br />

V7.0 SP2; for WinCC V7.0 SP2 6AV6 371-1DG07-0AX0<br />

SIMATIC WinCC/ProAgent<br />

Upgrade<br />

to SIMATIC WinCC/ProAgent 6AV6 371-1DG07-0AX4<br />

V7.0 SP2<br />

4/105<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC options<br />

SIMATIC powerrate<br />

■ Overview<br />

SIMATIC powerrate, as an option for WinCC / <strong>PC</strong>S 7, ensures<br />

transparency in energy consumption from the infeed to the load.<br />

SIMATIC powerrate is used in all sectors in which WinCC or<br />

<strong>PC</strong>S 7 are deployed and energy efficiency considerations play a<br />

major role. Total integration into WinCC or <strong>PC</strong>S 7 means that<br />

there is no need for a special system environment. Predefined<br />

modules and symbols give you the assurance of building on<br />

tested product components, with interfaces that support<br />

customized expansion.<br />

SIMATIC powerrate therefore provides a solution that you can<br />

use to obtain an overview of the energy consumption of a plant<br />

easily and cost-effectively through integration in an existing<br />

SIMATIC SCADA system.<br />

4/106<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Identification of energy-intensive equipment and processes to<br />

develop measures for improving energy efficiency.<br />

Comparison of consumption profiles for more efficient<br />

processes.<br />

Optimization of the company according to energy parameters,<br />

based on an evaluation of consumption and costs.<br />

Compliance with the contractually agreed power limits, thus<br />

preventing higher power supply costs or penalty payments.<br />

Integration of the SENTRON PAC3200/4200 Power Monitoring<br />

Devices for a clear overview of selected measured values and<br />

alarms.<br />

Integration of switches with an overview of the switch status<br />

and the switching possibilities.<br />

Accurate assignment and comparison of the consumption<br />

data of specific work processes or batches<br />

■ Design<br />

SIMATIC WinCC powerrate comprises the following components:<br />

Blocks for acquiring and conditioning energy data<br />

Faceplates for displaying and editing energy data<br />

Blocks for implementing load management (calculating the<br />

trend, monitoring the limit, releasing/inhibiting loads), batchrelated<br />

consumption recording and for integrating measuring<br />

instruments and switches<br />

Additional blocks – for example for time synchronization, data<br />

backup, data exchange with archives<br />

Faceplates for displaying results and entering values<br />

(e.g. for configuration, or manually measured values)<br />

Excel-based reports for allocating energy data to cost<br />

centers, for batch-related evaluation and for determining and<br />

displaying the load duration curve<br />

Exporting data to Excel


■ Function<br />

Acquiring and conditioning energy data<br />

Using ready-to-use function blocks, energy data can be<br />

acquired by any PROFIBUS-capable devices. The data can be<br />

input to the function blocks in the form of counter pulses, count<br />

values or power values. Count values can also be entered<br />

manually.<br />

From this data, the function block calculates the power averages<br />

and the work values for a predefined period. This calculated<br />

data is subsequently saved in the WinCC archive. In addition, a<br />

final value forecast is extrapolated for the power values for each<br />

period.<br />

A sample function (heat calculation) that can be adapted to the<br />

needs of the customer at any time by means of open interfaces<br />

has been implemented for the purpose of visualizing customized<br />

calculations. Data from manually read counters can be entered<br />

directly into the system and used for further analysis. Absolute<br />

numerical values (entry of an absolute value instead of the<br />

difference from the previous value) can also be recorded and<br />

used in further processing.<br />

Presentation of the energy data<br />

The up-to-date, acquired energy data is displayed as power<br />

averages/work values for each time interval (total value for the<br />

previous interval, current value of the current interval, extrapolated<br />

value for the end of the current interval). Load curve<br />

display enables analysis of archived energy data as well as its<br />

tabular representation.<br />

Further processing of the data<br />

The archived data can be exported to Excel directly from WinCC<br />

using the export functions. The exported energy data can also<br />

be included in further customized processing. WinCC tools can<br />

be used to access the data from the WinCC archive.<br />

Reports<br />

For this purpose, selected energy data is read from archives<br />

(Tag Logging archive, user archives) from the WinCC Runtime<br />

database; using Microsoft Excel the following reports can then<br />

be generated:<br />

Cost center report<br />

Here the consumption can be allocated to different cost<br />

centers and the costs can be calculated on the basis of<br />

predefined tariffs. The results can be output by means of<br />

2 reports in the form of tables or diagrams.<br />

Load duration curve<br />

An analysis is carried out on the basis of the archived power<br />

averages to establish how often a certain power average has<br />

occurred in a given period. It can be quickly detected from<br />

this characteristic curve whether temporary power peaks exist<br />

which can represent a possible starting point for cost savings<br />

by means of load management.<br />

Batch report<br />

This is used to allocate consumption to batches, whereby the<br />

data can be presented in chronological order or in order of<br />

batch name.<br />

The generation of exports or reports can be activated manually<br />

or automatically time-controlled (daily, weekly or monthly). Data<br />

access and report generation can also take place via a separate<br />

"office" <strong>PC</strong>; which enables the WinCC installation and the "office"<br />

applications to be distributed across different <strong>PC</strong>s.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SIMATIC WinCC options<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC powerrate<br />

Load management<br />

Contractually agreed power limits (in the case of electricity,<br />

normally the 15-minute average power value) must be observed,<br />

otherwise significantly higher supply prices or even penalty<br />

payments may become due to the energy supply company. The<br />

load management feature of SIMATIC WinCC powerrate carries<br />

out cyclic trend calculations in order to issue warnings/alarms if<br />

violation of the limit is likely and to switch off loads in accordance<br />

with the given configuration should this be required. If a limit is<br />

exceeded despite this, the latest load management data is<br />

archived to enable future evaluation or analysis.<br />

To prevent unnecessary switching operations, numerous parameters<br />

are available for adapting the load management to the<br />

current process conditions – and all this can be done easily and<br />

conveniently via the faceplate.<br />

For loads that are distributed over different PLCs, SIMATIC<br />

WinCC powerrate contains appropriate PLC-to-PLC communication<br />

blocks which can be used to integrate these loads into the<br />

load management system. Load management is scalable,<br />

according to the maximum number of loads to be integrated or<br />

monitored, for up to 10, 25, 50, 75 or 100 loads. Load<br />

management can be performed for different media<br />

(e.g. electricity, gas) simultaneously.<br />

Batch-related consumption recording<br />

A batch comprises all the units of a product that have been<br />

produced in one production cycle, i.e. under identical conditions.<br />

Batch-related consumption recording allows accurate<br />

recording of energy consumption for each batch. Batch-related<br />

consumption recording is possible for five types of energy each<br />

with up to 10 loads. Appropriate reports can be generated for<br />

analysis of the data (see also the batch report).<br />

Integration of SENTRON PAC3200/PAC4200<br />

When the SENTRON PAC3200/PAC4200 Power Monitoring<br />

Devices are integrated via DPV1 communication, selected<br />

measured values can be displayed and alarms (current, voltage,<br />

pulse frequency too high) can be generated from the digital<br />

status information and displayed.<br />

Integration of switches<br />

Switch integration via digital inputs/outputs (DI/DO) supports<br />

display of the switch status (On, Off, tripped, unplugged).<br />

With the appropriate authorization, switching is also possible via<br />

the faceplate. Switching takes place in a 2-step operation<br />

(switch command is issued, followed by a prompt for repeated<br />

confirmation; the switch command is not forwarded to the switch<br />

until confirmation has been received).<br />

WinCC Web Navigator support<br />

Makes the powerrate functionality available over the Web.<br />

Additional functions<br />

To avoid data loss in the event of a communication fault, the data<br />

is stored temporarily in a circulating buffer on the S7.<br />

4/107<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC options<br />

SIMATIC powerrate<br />

■ Technical specifications ■ Ordering data Order No.<br />

SIMATIC powerrate V4.0<br />

SIMATIC powerrate<br />

B 6AV6 372-1DE04-0AX7<br />

Hardware requirements<br />

V4.0 trial license<br />

SIMATIC powerrate can<br />

be used in the <strong>PC</strong>S 7 or<br />

<strong>PC</strong>S 7<br />

<strong>ST</strong>EP 7 and WinCC SCADA<br />

Limited 30-day ES + OS Runtime<br />

license<br />

WinCC SCADA environments.<br />

For installation, the respective<br />

SIMATIC powerrate<br />

V4.0 ES + OS Runtime<br />

hardware requirements of the<br />

following products apply:<br />

Released CPUs – SIMATIC<br />

powerrate is released in the<br />

<strong>PC</strong>S 7 environment for:<br />

S7-400 CPUs supported by <strong>PC</strong>S 7<br />

WinAC RTX 2010<br />

Released CPUs – SIMATIC<br />

powerrate is released in the<br />

WinCC SCADA environment<br />

for:<br />

Software requirements<br />

S7-400<br />

S7-300<br />

- SIMATIC S7 CPU 319-3 PN/DP V2.5<br />

and higher<br />

- SIMATIC S7 CPU 317-2 PN/DP V2.6<br />

and higher<br />

- SIMATIC S7 CPU 315-2 PN/DP V3.1<br />

and higher<br />

WinAC RTX 2010<br />

You can use SIMATIC<br />

<strong>PC</strong>S 7<br />

powerrate in the <strong>PC</strong>S 7 or<br />

WinCC SCADA environments.<br />

For installation, the respective<br />

software requirements of the<br />

following products apply:<br />

<strong>ST</strong>EP 7 and WinCC SCADA<br />

The library is released for the SIMATIC <strong>PC</strong>S 7 V7.1 SP2<br />

following <strong>PC</strong>S 7 versions: SIMATIC <strong>PC</strong>S 7 V7.1 SP1<br />

SIMATIC <strong>PC</strong>S 7 V7.1<br />

The library is released for the<br />

following WinCC version with<br />

the corresponding versions of<br />

<strong>ST</strong>EP 7:<br />

SIMATIC WinCC V7.0 SP2<br />

For use with WinCC V7.0 SP2, WinCC minimum installation<br />

the following installations are - Basic Process Control<br />

required:<br />

- User archives for load management<br />

and batch-oriented energy acquisition<br />

WinCC add-on "AS-OS Engineering"<br />

For the use of SIMATIC powerrate<br />

V4.0, WinCC must execute in<br />

integrated mode with <strong>ST</strong>EP 7.<br />

SIMATIC NET<br />

<strong>ST</strong>EP 7<br />

powerrate Reports has been Microsoft Excel 2003<br />

released for the following<br />

versions:<br />

Microsoft Excel 2007<br />

1)<br />

Also included are<br />

License for user/archive<br />

B 6AV6 372-1DE04-0AX0<br />

PAC3200 function block library<br />

for WinCC<br />

Block library PAC3200, 3WL/3VL<br />

for <strong>PC</strong>S 7<br />

SIMATIC powerrate V4.0<br />

upgrade V3.0 to V 4.0,<br />

ES + OS-RT 1)<br />

A 6AV6 372-1DE04-0AX4<br />

■ More information<br />

Further information can be found on the Internet at:<br />

www.siemens.com/simatic-powerrate<br />

Important information on the use of SIMATIC powerrate is<br />

available on the Internet at:<br />

http://support.automation.siemens.com/WW/view/en/48204134/133200<br />

4/108<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

1) For operation on a WinCC/<strong>PC</strong>S 7 OS single-user workstation or server<br />

and any number of automation systems. When using additional<br />

WinCC/<strong>PC</strong>S 7 OS single-user stations/servers, one license is required<br />

per WinCC/<strong>PC</strong>S 7 OS single-user station/server.


■ Overview<br />

Energy Management System SIMATIC WinCC/B.Data V5.2<br />

WinCC/B.Data provides the user with a modular and sectorneutral<br />

energy management and plant information system for<br />

industrial plants.<br />

Automation<br />

field level<br />

■ Benefits<br />

Energy management – Company portal<br />

B.Data<br />

WinCC<br />

Energy purchase<br />

Purchase support<br />

Scenario calculator<br />

Forecast<br />

Energy forecast<br />

Budget planning<br />

Energy schedule<br />

Energy purchase schedule<br />

Specifications for Load management<br />

Fault/alarm management<br />

Alarms/messages<br />

Remote alarms (text message)<br />

Interfaces to lower-level systems Meters/<br />

measuring<br />

devices<br />

The option WinCC/B.Data forms the basis of a cost-effective<br />

energy management system for reducing energy costs and<br />

increasing energy efficiency, and it confers the following<br />

immediate benefits:<br />

It creates company-wide transparency, thanks to continuous<br />

energy balancing and materials balancing for the power<br />

generation systems and loads<br />

It allows energy costs to be allocated according to the costsby-cause<br />

principle and permits transfer to the billing system<br />

(e.g. SAP R/3 CO)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Energy planning and procurement Energy controlling Monitoring and reporting<br />

Emission<br />

CO2 emission monitoring<br />

Wastewater disposal<br />

Energy accounting<br />

Cost center allocation<br />

Evaluation/invoicing<br />

Energy and material balance<br />

KPI calculation<br />

Production allocation<br />

Operation and control system<br />

Central detection<br />

Plant visualization<br />

Data processing and archiving<br />

Process<br />

control/<br />

building<br />

management<br />

systems<br />

PLCs Circuitbreakers<br />

HMI Software<br />

SIMATIC WinCC options<br />

Connection of external systems<br />

Facility management<br />

ERP (e.g. SAP R/3)<br />

Maintenance management<br />

Energy reporting system<br />

Analysis and reporting<br />

Workflow system<br />

Intranet/Internet viewer<br />

Load management<br />

Load shedding<br />

Load control<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

WinCC/B.Data<br />

Mobile<br />

data<br />

acquisition<br />

It generates characteristic values for well-informed<br />

suggestions for increasing the efficiency of power generation<br />

systems and loads<br />

It provides planning reliability thanks to production-related<br />

load and demand forecasts<br />

It supports purchasing with cost-optimized energy<br />

procurement<br />

It fulfills the legal obligations for monitoring and reporting on<br />

greenhouse gas emissions (CO 2 emissions)<br />

It relieves personnel of extra work through automatically<br />

updating internal and external energy reports.<br />

G_<strong>ST</strong><strong>80</strong>_XX_00379<br />

4/109<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC options<br />

WinCC/B.Data<br />

■ Design<br />

WinCC/B.Data V5.2 basic system<br />

The WinCC/B.Data basic system is available in versions for 100,<br />

500, 1,000 and 30,000 tags and comprises the following components:<br />

A B.Data acquisition component (WinCC, O<strong>PC</strong>, etc.)<br />

A B.Data Client<br />

B.Data Mobile<br />

ERP interface<br />

Reporting, Trender, Visu, document management, Matrix, KPI,<br />

Profile<br />

WinCC/B.Data V5.2 SUS & support contract<br />

For each WinCC/B.Data basic system there is a corresponding<br />

SUS and support contract, which is dependent on the number of<br />

tags. The Software Update Service (SUS) is included, as well as<br />

Basic and Extended Technical Support (hotline).<br />

The SUS and the support contract run for 1 year. The contract is<br />

automatically extended by 1 more year unless canceled<br />

3 months prior to expiration.<br />

WinCC/B.Data V5.2 expansions<br />

The scope of B.Data can be extended by purchasing add-on<br />

packages:<br />

WinCC/B.Data V5.2 Web Server<br />

WinCC/B.Data V5.2 Client<br />

WinCC/B.Data V5.2 energy forecasting and planning<br />

WinCC/B.Data V5.2 acquisition components<br />

■ Function<br />

Acquisition and pre-processing of energy and operating<br />

data from WinCC<br />

In addition to an interface to WinCC, WinCC/B.Data also offers<br />

the latest interface standards, such as O<strong>PC</strong>, ODBC, ASCII or<br />

XML<br />

Preprocessing of energy data in a real-time calculation core<br />

that can be freely modeled including a formula editor for<br />

defining and configuring new calculation functions (heat<br />

calculations for boilers, quality for cogeneration plants, etc.)<br />

B.Data Mobile for mobile recording of energy data including<br />

route planning for meter reading operations. Management<br />

and analysis of energy data<br />

Automatic plausibility check and generation of simulated<br />

values<br />

Long-term archive with versioning, compression and<br />

consolidation functions<br />

Measured value editor for entering and processing energy<br />

and operating values<br />

Trender for presenting up-to-date (online) and historical load<br />

curves (trends), also for setpoint/actual value analyses.<br />

4/110<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Energy and material balance<br />

Freely parameterizable balancing of the energy flows of various<br />

media such as electricity, heat, gas, steam, and emissions (CO2) in the B.Data Plant Explorer<br />

Calculation of characteristic values (KPIs, efficiency<br />

coefficients, etc.) with direct reference to production (batches,<br />

quantities, etc.).


Counter 2<br />

Energy planning<br />

Generation of requirement forecasts based on productiondependent<br />

factors (production planning) and basic load<br />

profiles (typical days)<br />

Energy reporting<br />

Generation of energy schedules for registering with the<br />

energy suppliers. Energy reporting<br />

Freely parameterizable report generator for creating<br />

balances, protocols, shift logs, bills<br />

Fully automated reporting with task management, e-mail<br />

dispatch and document management<br />

B.Data Intranet/Internet viewer (web client) for company-wide<br />

viewing of reports and results.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_003<strong>80</strong><br />

HMI Software<br />

SIMATIC WinCC options<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

WinCC/B.Data<br />

■ Function (continued)<br />

■ Technical specifications<br />

Energy accounting (costs and revenue accounting)<br />

SIMATIC WinCC/B.Data V5.2<br />

Calculation and allocation/assignment of energy costs to plants Operating system<br />

and/or customers/cost units in accordance with the costs-bycause<br />

principle. The bottom up (measurement) and top down<br />

(allocation) procedures are supported here.<br />

Flexible modeling of the hierarchic accounting structures in<br />

the Plant Explorer<br />

Tariff allocation of quantities, flexible price assessment with<br />

tariff and price time series<br />

Transfer of costs/revenues to the ERP system<br />

(e.g. SAP R/3 CO)<br />

Client and function/acquisition<br />

server<br />

Losses<br />

Accounting area<br />

(e.g. Cost center)<br />

Factors are based on:<br />

Numbers of<br />

employees<br />

Area data<br />

Allocation formula<br />

10% 90%<br />

20% <strong>80</strong>%<br />

etc.<br />

Consumption area<br />

(e.g.: Building 1)<br />

1 ... n Consumption area<br />

(e.g.: Building 2)<br />

100% Distribution<br />

ensured<br />

75% 25%<br />

Counter 1 Counter 3<br />

1) :<br />

Windows Server 2003 SP2<br />

32 bit Eng./Ger.<br />

Windows Server 2008<br />

Std. Edition 32 bit Eng./Ger.<br />

Windows XP Professional SP3<br />

32 bit Eng./Ger.<br />

Windows 7 Professional/Ultimate<br />

32 bit Eng./Ger. (for B.Data client only)<br />

Minimum of 1 GB RAM<br />

Database Windows Server 2003 SP2<br />

32 bit Eng./Ger.<br />

Windows Server 2008<br />

Std. Edition 32 bit Eng./Ger.<br />

XP Professional SP3 32 bit Eng./Ger.<br />

Minimum of 2 GB RAM<br />

Interface In addition to an interface to WinCC,<br />

B.Data also offers the latest interface<br />

standards, such as O<strong>PC</strong>, ODBC, ASCII<br />

and XML.<br />

1) If an acquisition computer is installed on a WinCC system, these<br />

requirements must also be complied with.<br />

2) An Oracle® Database 11gR2 32-bit in the Standard Edition One,<br />

Standard Edition or Enterprise Edition version is a prerequisite for use<br />

of B.Data V5.2.<br />

4/111<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC options<br />

WinCC/B.Data<br />

■ Ordering data Order No. Order No.<br />

WinCC/B.Data V5.2 basic<br />

system<br />

In the basic system of B.Data, the<br />

following components are already<br />

included:<br />

One B.Data acquisition<br />

component (WinCC, O<strong>PC</strong>, etc.),<br />

1 B.Data client, B.Data Data<br />

Mobile, ERP interface, Reporting,<br />

Trender, Visu, document<br />

management, Matrix, KPI, Profile<br />

Basic system, 100 tags 1) E 6AV6 372-1DF05-2AX0<br />

SUS and support contract for<br />

100 tags 2)<br />

E 6AV6 372-1DF00-0AL0<br />

Basic system, 500 tags 1) E 6AV6 372-1DF05-2BX0<br />

SUS and support contract for<br />

500 tags 2)<br />

E 6AV6 372-1DF00-0BL0<br />

Basic system, 1000 tags 1) E 6AV6 372-1DF05-2CX0<br />

SUS and support contract for<br />

1000 tags 2)<br />

E 6AV6 372-1DF00-0CL0<br />

Basic system, 30000 tags 1) E 6AV6 372-1DF05-2DX0<br />

SUS and support contract for<br />

30000 tags 2)<br />

E 6AV6 372-1DF00-0DL0<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

1) With each WinCC/B.Data Basic System / Power Pack, a corresponding<br />

SUS and support contract must also be ordered. The<br />

Software Update Service (SUS) is included, as well as Basic and<br />

Extended Technical Support (hotline).<br />

2) The SUS and the support contract run for 1 year. The contract is<br />

automatically extended by a further year unless canceled 3 months<br />

prior to expiration. According to terms of license, an SUS and support<br />

contract must be ordered for the corresponding number of days in the<br />

system. When ordering Power Packs for the Basic System, a Power<br />

Pack must therefore also be ordered for the SUS.<br />

4/112<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

WinCC/B.Data V5.2 Power Pack<br />

Basic system, Power Pack 1)<br />

Tag upgrade by 1 level<br />

E 6AV6 372-1DF05-2XX0<br />

SUS and support contract for<br />

Power Pack 2)<br />

WinCC/B.Data V5.2 Trial<br />

License<br />

E 6AV6 372-1DF00-0XL0<br />

Basic system, 30 days<br />

WinCC/B.Data V5.2 expansions<br />

The functional scope of B.Data<br />

can be expanded with the<br />

following packages.<br />

E 6AV6 372-1DF15-2AX0<br />

WinCC/B.Data V5.2 Web Server<br />

incl. 3 web clients E 6AV6 372-1DF25-2AX0<br />

incl. 20 web clients E 6AV6 372-1DF25-2BX0<br />

WinCC/B.Data V5.2 Client E 6AV6 372-1DF35-2AX0<br />

WinCC/B.Data V5.2<br />

Planning & Forecast<br />

E 6AV6 372-1DF45-2AX0<br />

WinCC/B.Data V5.2<br />

acquisition components<br />

E 6AV6 372-1DF55-2AX0


■ Overview<br />

The WinCC/DataMonitor is a component of WinCC Plant<br />

Intelligence and is used for displaying and evaluating current<br />

process statuses and historical data on office <strong>PC</strong>s with<br />

standard tools such as Microsoft Internet Explorer or Microsoft<br />

Excel. The DataMonitor Client is supported by a web server<br />

with current and historic process data and alarms. All staff<br />

ranging from machine operators to corporate managers can<br />

use the DataMonitor to obtain information.<br />

DataMonitor is a suite of Internet-capable tools:<br />

- Process Screens - Tool for simple visualization and<br />

navigation through WinCC screens using WinCC Web<br />

Viewer (WinCC Viewer RT)<br />

- Excel Workbooks - Protocol tool that integrates WinCC<br />

archives and online values into MS Excel and supports<br />

online analysis<br />

- Published Reports - Event- or time-driven execution of Excel<br />

or PDF reports for the output of process data and analysis<br />

results<br />

- Web center - Individual configuration of Internet pages and<br />

summary of information within a portal in terms of WinCC<br />

applications<br />

- Trends and Alarms are preconfigured Web Center pages<br />

DataMonitor does not require manual client installation<br />

because it loads the required components from the web<br />

server. Additional administration is unnecessary as a result.<br />

There is no installation required on the client for the<br />

Webcenter, Trends and Alarms functions.<br />

Licenses for simultaneous access by 1, 3, 10, 25 or 50<br />

DataMonitor clients. Any combination of DataMonitor and Web<br />

Navigator licenses can be used for an application.<br />

Pre-created Webcenter pages<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

HMI Software<br />

SIMATIC WinCC options<br />

WinCC/DataMonitor<br />

Information can be compiled online individually during<br />

runtime via the Internet/Intranet.<br />

Efficiently monitor and analyze production lines.<br />

- Display and evaluation of current process states and<br />

historical data on remote office <strong>PC</strong>s with standard tools such<br />

as Microsoft Internet Explorer or Excel.<br />

- Easy access to production data via the Intranet or Internet<br />

- Quick ascertainment of the production situation<br />

- Use of standard products<br />

Easily collect and distribute information.<br />

- Automated report creation<br />

- No additional configuration effort through direct use of<br />

images from the WinCC project<br />

- No training required for standard products<br />

- Easy exchange of configuration data<br />

Substantiate decisions with reports.<br />

- Evaluation via ready-made templates for special analyses of<br />

the business processes (e.g. reports, statistics)<br />

- Make bottlenecks transparent<br />

- Individual views for user and situation<br />

- Relative and absolute timeframe for information generation<br />

View production status anywhere and anytime.<br />

- Individual views of information in production<br />

- View the process and system operation<br />

- Historical data can be compiled online individually<br />

Highlights<br />

Access to the lower-level servers when installing the<br />

DataMonitor server on a WinCC Client with a separate project<br />

(RT128 license)<br />

Tag logging archive tags can be accessed by means of the<br />

web center function without changing the WinCC<br />

configuration system.<br />

Installation of the DataMonitor web center function on a<br />

WinCC file server<br />

Dedicated Internet pages can be created for displaying data<br />

with the Webcenter. For this purpose, the following tools which<br />

can be integrated in the Internet sites are available.<br />

- Bar diagram, pie chart, trend curve display<br />

- Process value table and statistics functions for the process<br />

values<br />

- Alarms, hit list for alarms<br />

- Message text display for individual message texts, message<br />

display, selection list of created reports<br />

- Links to internal and external pages<br />

- Display of graphics in jpg format<br />

- Visualization of the WinCC process screens without<br />

installation download<br />

The analyses can be made with relative or absolute time<br />

specification. This enables comparisons of identical time<br />

periods on different days.<br />

Reports generated with Excel or the WinCC Report Designer<br />

can be made available on the DataMonitor server or e-mailed<br />

automatically to the relevant group of people based on time<br />

intervals or triggered by events.<br />

Connections can be established to WinCC Runtime, the<br />

central archive server, and swapped-out archives<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/113<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC options<br />

WinCC/DataMonitor<br />

■ Benefits (continued)<br />

■ Ordering data Order No.<br />

Innovations of V7.0<br />

WinCC/DataMonitor V7.0 for<br />

DataMonitor<br />

- Supports Internet Explorer V 7.0 including tabbed browsing.<br />

- User-friendly web interface for all DataMonitor functions<br />

DataMonitor/ProcessScreens<br />

- The screens are displayed in the WinCC Web Viewer in View<br />

only mode of the Web Navigator.<br />

DataMonitor/Webcenter<br />

- Enhanced user management for the web center in order to<br />

assign individual Internet pages and created reports to<br />

specific user groups.<br />

- Integrating WinCC process screens on Internet pages<br />

without installation download<br />

- Representation of preprocessed process data<br />

- A search function facilitates the management of connections<br />

WinCC V7.0, WinCC V7.0 SP1/<br />

SP2 and WinCC V7.0 SP1/SP2<br />

ASIA<br />

1 client license<br />

3 client licenses<br />

10 client licenses<br />

25 client licenses<br />

50 client licenses<br />

WinCC/DataMonitor<br />

Power Packs V7.0<br />

From 1 to 3 clients<br />

From 3 to 10 clients<br />

From 10 to 25 clients<br />

From 25 to 50 clients<br />

6AV6 371-1DN07-0LX0<br />

6AV6 371-1DN07-0AX0<br />

6AV6 371-1DN07-0BX0<br />

6AV6 371-1DN07-0CX0<br />

6AV6 371-1DN07-0DX0<br />

6AV6 371-1DN07-0LA0<br />

6AV6 371-1DN07-0AB0<br />

6AV6 371-1DN07-0BC0<br />

6AV6 371-1DN07-0CD0<br />

to the WinCC Server.<br />

- Swapped out archives can be connected and evaluated in<br />

the DataMonitor web center.<br />

- Automatic pre-assignment of the colors for representation in<br />

the value display tools.<br />

- Expansion of the display area in the Webcenter (Menu Hide<br />

WinCC/DataMonitor, Upgrade<br />

from V6.0 to V7.0<br />

from V6.2 to V7.0<br />

from V6.x to V6.2 SP3<br />

from V6.x ASIA to V6.2 SP3 ASIA<br />

6AV6 371-1DN07-0XX4<br />

6AV6 371-1DN07-0XX3<br />

6AV6 371-1DN06-2XX3<br />

6AV6 371-1DN06-2XV3<br />

function)<br />

WinCC/DataMonitor V6.2 SP3<br />

- Delete layout and Webcenter pages<br />

for WinCC V6.2 SP3<br />

DataMonitor/Reports<br />

- Excel reports created offline can be loaded onto the<br />

DataMonitor server and are thus made available to selected<br />

user groups or for automatic distribution.<br />

1 client license<br />

3 client licenses<br />

10 client licenses<br />

25 client licenses<br />

50 client licenses<br />

6AV6 371-1DN06-2LX0<br />

6AV6 371-1DN06-2AX0<br />

6AV6 371-1DN06-2BX0<br />

6AV6 371-1DN06-2CX0<br />

6AV6 371-1DN06-2DX0<br />

■ Function<br />

All tools are fully Internet-compatible and, therefore, support<br />

access via any type of connection (LAN, GSM, radio, modem,<br />

Internet, etc.).<br />

All popular security mechanisms such as login/password,<br />

firewalls, encryption, etc. are supported.<br />

WinCC/DataMonitor V6.2 SP3<br />

ASIA for WinCC V6.2 SP3 ASIA<br />

1 client license<br />

3 client licenses<br />

10 client licenses<br />

25 client licenses<br />

50 client licenses<br />

6AV6 371-1DN06-2LV0<br />

6AV6 371-1DN06-2AV0<br />

6AV6 371-1DN06-2BV0<br />

6AV6 371-1DN06-2CV0<br />

6AV6 371-1DN06-2DV0<br />

Users can combine the available tools at will. Licensing only<br />

takes into account simultaneous access to one Web server.<br />

WinCC/DataMonitor,<br />

Power Packs V6.2<br />

For display purposes, screens from the WinCC project can be From 1 to 3 clients 6AV6 371-1DN06-2LA0<br />

used or special overview displays configured. Animations, From 3 to 10 clients 6AV6 371-1DN06-2AB0<br />

scripts, navigation and access rights remain valid.<br />

From 10 to 25 clients 6AV6 371-1DN06-2BC0<br />

The WinCC/DataMonitor supports a display function only,<br />

local access to the process sequence is prevented.<br />

Company-wide Excel reports, which contain historical and<br />

current process values, can be stored centrally for general<br />

access (reports, statistics). However, local queries to meet<br />

individual requirements can be compiled and executed<br />

online. Plot and tabular representation are supported for<br />

archive data already swapped out.<br />

Data can be automatically entered into created report<br />

templates and distributed by e-mail or saved on the server.<br />

Pre-made elements make the assembly of individual web<br />

pages easier for evaluating information.<br />

Individual information compilation on one or more Internet<br />

pages with the option of branching to other detail pages.<br />

Pre-made Internet pages for trend and alarm display enable<br />

an ad-hoc entry to Internet data evaluation.<br />

A higher-level navigation feature provides a common<br />

framework for the various tools.<br />

From 25 to 50 clients 6AV6 371-1DN06-2CD0<br />

4/114<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Overview<br />

The entry point to SIMATIC Plant Intelligence can occur through<br />

options for the SIMATIC WinCC process visualization system.<br />

The WinCC/DowntimeMonitor is a component of WinCC Plant<br />

Intelligence and is used for monitoring the efficiency and performance<br />

of individual machine modules, subsystems and<br />

production lines. The combined elements to be monitored are<br />

designated as equipment. Using the WinCC/DowntimeMonitor,<br />

the machine data management software, standstill time can be<br />

recorded and analyzed centrally in production. For individual<br />

devices, machines or entire production lines, the specific<br />

parameters can be determined this way. Integration into WinCC<br />

ensures complete transparency of all machine and plant data as<br />

a basis for optimizing the plant's productivity.<br />

The process values are read directly from WinCC and are<br />

connected with the respective analysis function.<br />

The SIMATIC WinCC DowntimeMonitor can be installed on a<br />

WinCC single station, WinCC Server or WinCC Client with<br />

project (RT128 license), and consists of an Engineering Client<br />

as well as a Runtime User interface.<br />

All engineering operations are performed using a graphic<br />

Engineering Client. The Engineering Client is called up from<br />

the WinCC Explorer.<br />

SIMATIC WinCC DowntimeMonitor provides ActiveX control<br />

elements. These are used for displaying the determined<br />

parameters and the progress of the various status over a<br />

certain time period. These controls are integrated in WinCC<br />

process images for presenting results.<br />

The recorded data is stored in an online database set and can<br />

be moved to an offline database set.<br />

The basic package consists of the Engineering and Runtime<br />

software and 5 licensed equipment units. Other licenses are<br />

available for up to 25, up to 50, 100 and up to 200 equipment<br />

units.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

HMI Software<br />

SIMATIC WinCC options<br />

WinCC/DowntimeMonitor<br />

Recording failure times, localizing causes and reasons for<br />

failure times, and monitoring of equipment efficiency.<br />

Weak-point analysis in production processes and recording of<br />

undesirable process activities.<br />

Basis for decision making based on performance indicators.<br />

Identification of the events that lead to cost-intensive failures.<br />

Entry point for an extended downtime analysis with upgrade<br />

options in the MES software SIMATIC IT.<br />

Identification of speed and quality losses.<br />

Complete transparency for all machines as basis for<br />

optimizing the plant's productivity. Faults and bottlenecks are<br />

prevented to increase availability.<br />

Derivation of specific parameters (KPI – Key Performance<br />

Indicators).<br />

Integration of respective display instruments (controls) in<br />

WinCC process images.<br />

Can be utilized for individual machines or even complete<br />

production plants.<br />

Distribution of evaluations to various people over the web.<br />

■ Function<br />

Creation of a time model by defining various time categories<br />

as a basis for the KPI calculation for elements (equipment) to<br />

be evaluated.<br />

Creation of equipment, as central components for the<br />

evaluation by dividing the system into individual groups.<br />

Creation of a Reason Tree for detailed display of reasons for<br />

downtimes.<br />

Allocation of the system status in the controller to the time<br />

categories and Reason Trees defined in the DowntimeMonitor.<br />

Storing the system status for calculating and presenting Key<br />

Performance Indicators.<br />

The following pre-defined Key Performance Indicators are<br />

available: Availability, change-over, cycle time, failure time<br />

loss, duration, effective performance, maintenance, Mean<br />

Time Between Assist (MTBA), Mean Time Between Failures<br />

(MTBF), Mean Time To Assists (MTTA), Mean Time To Repair<br />

(MTTR), failure time frequency, Overall Equipment<br />

Effectiveness (OEE), performance rate, production duration,<br />

quality rate, speed loss, Total Efficient Equipment<br />

Performance (TEEP), utilization.<br />

Integration of three new controls Gant View, KPI View, and<br />

Table View in WinCC for the display of results for one or more<br />

equipment units.<br />

The WinCC DowntimeMonitor Gant View presents the<br />

equipment status development within a certain time period.<br />

The WinCC DowntimeMonitor KPI View shows the distribution<br />

of failure times and the Key Performance Indicators in a trend,<br />

bar, segmented bar charts or Pareto chart using historical<br />

data.<br />

The WinCC DowntimeMonitor Table View shows raw data for<br />

failure times and analyzes it in the selected time period. The<br />

user can utilize these control elements to enter, change,<br />

distribute or combine and comment on failure times manually.<br />

The controls can be displayed on Intranet or Internet using the<br />

option WinCC/Web Navigator.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/115<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC options<br />

WinCC/DowntimeMonitor<br />

■ Ordering data Order No. Order No.<br />

WinCC/DowntimeMonitor V7.0<br />

SP1 for WinCC V7.0 SP1 and<br />

WinCC V7.0 SP1 ASIA<br />

5 equipment units 6AV6 372-1DB07-0BX0<br />

25 equipment units 6AV6 372-1DB07-0DX0<br />

50 equipment units 6AV6 372-1DB07-0FX0<br />

100 equipment units 6AV6 372-1DB07-0HX0<br />

200 equipment units 6AV6 372-1DB07-0KX0<br />

WinCC/DowntimeMonitor<br />

Power Packs V7.0<br />

from 5 to 25 equipment units 6AV6 372-1DB07-0BD0<br />

from 25 to 50 equipment units 6AV6 372-1DB07-0DF0<br />

from 50 to 100 equipment units 6AV6 372-1DB07-0FH0<br />

from 100 to 200 equipment units 6AV6 372-1DB07-0HX0<br />

WinCC/DowntimeMonitor<br />

upgrade<br />

V1.x to V7.0 SP1 6AV6 372-1DB07-0XX4<br />

4/116<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

WinCC/DowntimeMonitor V1.0<br />

SP1 for WinCC V6.2 SP2 and<br />

WinCC V6.2 SP2 ASIA<br />

5 equipment units 6AV6 372-1DB06-2BX0<br />

25 equipment units 6AV6 372-1DB06-2DX0<br />

50 equipment units 6AV6 372-1DB06-2FX0<br />

100 equipment units 6AV6 372-1DB06-2HX0<br />

200 equipment units<br />

WinCC/DowntimeMonitor<br />

Power Packs V1.0<br />

6AV6 372-1DB06-2KX0<br />

from 5 to 25 equipment units 6AV6 372-1DB06-2BD0<br />

from 25 to 50 equipment units 6AV6 372-1DB06-2DF0<br />

from 50 to 100 equipment units 6AV6 372-1DB06-2FH0<br />

from 100 to 200 equipment units 6AV6 372-1DB06-2HX0


■ Overview<br />

Cross-vendor communication in the automation sector has<br />

always been of primary importance for WinCC. This is even<br />

more true for the release of preprocessed production data for<br />

higher-level information systems (e.g., MES = Management<br />

Execution System, ERP = Enterprise Resource Planning or<br />

Office packages = MS Excel, MS Access etc.). WinCC features<br />

integrated O<strong>PC</strong> Data Access and O<strong>PC</strong> XML DA servers for<br />

access to all online values in the system and makes open<br />

interfaces available for access to historical WinCC data.<br />

The Connectivity Pack includes O<strong>PC</strong> XML DA 1.00,<br />

O<strong>PC</strong> HDA 1.20 (Historical Data Access), O<strong>PC</strong> A&E 1.10<br />

(Alarm & Events) and a WinCC OLE-DB interface which<br />

even allows remote computers without WinCC to access<br />

WinCC archive and alarm data.<br />

The function of the O<strong>PC</strong> servers (XML DA, HDA and A&E) is<br />

assured by the WinCC/Connectivity Pack. In order to access<br />

data in the database via WinCC OLE-DB/OLE-DB, you will<br />

also need a license for the WinCC/Connectivity Pack.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SIMATIC WinCC options<br />

WinCC/Connectivity Pack &<br />

WinCC Connectivity Station<br />

A Connectivity Pack license is required for every<br />

WinCC system to be accessed.<br />

If the Connectivity Station is used, an additional<br />

Connectivity Pack license does not have to be installed on the<br />

WinCC systems that are accessed. The Connectivity Station<br />

functions autonomously and does not require a WinCC<br />

installation on the computer.<br />

For versions below V7.0<br />

Access to WinCC archive and alarm data from a computer<br />

without installed WinCC basic system license or WinCC option<br />

via the interfaces of the Connectivity Pack or Connectivity<br />

Station requires a WinCC/Client Access license on the client<br />

side (see also "WinCC/Client Access License").<br />

Connectivity Station Option for WinCC V6.2 and higher<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/117<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC options<br />

WinCC/Connectivity Pack &<br />

WinCC Connectivity Station<br />

■ Benefits<br />

Access to variables, historical WinCC data, alarm data and<br />

user archives from any computer<br />

Options for analyzing and evaluating process data with<br />

specialist tools or user-defined applications (e.g. via<br />

VisualBasic)<br />

■ Function<br />

As an O<strong>PC</strong> HDA server, WinCC makes historical data from the<br />

WinCC archive system available to other applications. An O<strong>PC</strong><br />

HDA client (e.g. a reporting tool) can define the time interval for<br />

the required data by entering a start and end time. O<strong>PC</strong> HDA<br />

servers also support the generation of a variety of aggregate<br />

functions on the server itself (e.g. standard deviation, variance,<br />

mean values, integral values, etc.), thereby helping to relieve the<br />

load on the network, as only preprocessed data are transmitted.<br />

O<strong>PC</strong> A&E servers are used to forward WinCC messages (along<br />

with all associated process values) to any client at production or<br />

enterprise control level. Filter mechanisms and subscriptions<br />

ensure that only selected modified data are transmitted.<br />

Acknowledgement is of course also supported.<br />

The WinCC O<strong>PC</strong> XML DA server makes cross-platform communication<br />

between Windows and non-Windows systems possible,<br />

even via the Internet. This enables read and write WinCC online<br />

values (external and internal WinCC variables) to be exchanged<br />

with non-<strong>Siemens</strong> systems.<br />

WinCC OLE-DB makes standardized and user-friendly access to<br />

WinCC archive data possible (MS SQL Server 2005). In exactly<br />

the same way as access via the O<strong>PC</strong> HDA and O<strong>PC</strong> A&E interfaces,<br />

access via the WinCC OLE DB provider makes all WinCC<br />

archive data available along with the associated process values<br />

and message/user texts. The WinCC OLE-DB provider also<br />

supports analysis functions such as minimum, maximum,<br />

message hit list, etc.<br />

The WinCC Connectivity Station was designed as a stand-alone<br />

gateway to WinCC server data. It supports access to WinCC<br />

server data over the O<strong>PC</strong> channels described as well as those<br />

for process values (not alarms) over OLE DB . Access to WinCC<br />

data is transparent, i.e. independent of which server of a<br />

redundant pair is active or whether data have already been<br />

transferred to the central archive server.<br />

4/118<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Connectivity Station<br />

If no visualization is required at a station, any Windows computer<br />

with access to WinCC via O<strong>PC</strong> and OLE-DB can be configured<br />

via the Connectivity Station. This permits access to WinCC<br />

stations with server packages from a central computer without<br />

WinCC installation. The WinCC stations can be accessed via the<br />

following interfaces:<br />

O<strong>PC</strong> interfaces of the Connectivity Station<br />

OLE DB interface of the Connectivity Pack<br />

The two access versions are autonomous access options with<br />

different ranges of functions.<br />

O<strong>PC</strong> interfaces of the Connectivity Station<br />

The Connectivity Station provides interfaces via which you can<br />

access the following using an O<strong>PC</strong>-Client.<br />

O<strong>PC</strong>-DA-Server: tags, e.g. process values<br />

O<strong>PC</strong>-HDA-Server: archived process values<br />

O<strong>PC</strong>-A&E-Server: alarms<br />

Licensing<br />

You require the "WinCC Connectivity Station" license in order to<br />

utilize the O<strong>PC</strong> interfaces of the Connectivity Station on a<br />

computer without WinCC installed.<br />

If you only use the O<strong>PC</strong> interfaces of a WinCC installation, you<br />

only need the "Connectivity Pack" license.<br />

The following table shows the combinations:<br />

Standard installation:<br />

O<strong>PC</strong> with WinCC<br />

New: WinCC-independent<br />

installation with<br />

Connectivity Station<br />

O<strong>PC</strong> DA "WinCC Connectivity Station"<br />

license<br />

O<strong>PC</strong> HDA "WinCC Connectivity Station"<br />

license<br />

O<strong>PC</strong> A&E "WinCC Connectivity Station"<br />

license<br />

No license required<br />

"WinCC Connectivity Pack"<br />

license<br />

"WinCC Connectivity Pack"<br />

license<br />

The Connectivity Station is planned over NCM <strong>PC</strong> Manager or<br />

SIMATIC Manager. In Version 7, the Connectivity Station does<br />

not run as service.


■ Ordering data Order No. Order No.<br />

WinCC/Connectivity Pack &<br />

WinCC/Connectivity Station<br />

V7.0; for WinCC V7.0, WinCC<br />

V7.0 SP1/ SP2 and<br />

WinCC V7.0 SP1/ SP2 ASIA<br />

Basic packages<br />

WinCC/Connectivity Pack<br />

V7.0 1)<br />

WinCC/Connectivity<br />

Station V7.0 1)<br />

6AV6 371-1DR07-0AX0<br />

6AV6 371-1DR17-0AX0<br />

1) Upgrades from V6.x to V7.x are included in the WinCC V7.x upgrades<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

WinCC/Connectivity Pack &<br />

WinCC/Connectivity Station<br />

V6.2 SP3; for WinCC V6.2 SP3<br />

and WinCC V6.2 SP3 ASIA<br />

Basic packages<br />

WinCC/Connectivity Pack V6.2<br />

SP3<br />

WinCC/Connectivity Station V6.2<br />

SP3<br />

WinCC/Connectivity Pack V6.2<br />

SP3 ASIA<br />

WinCC/Connectivity Station V6.2<br />

SP3 ASIA<br />

Upgrade1) WinCC/Connectivity Pack<br />

V6.x -> V6.2 SP3<br />

HMI Software<br />

SIMATIC WinCC options<br />

WinCC/Connectivity Pack &<br />

WinCC Connectivity Station<br />

6AV6 371-1DR06-2AX0<br />

6AV6 371-1DR16-2AX0<br />

6AV6 371-1DR06-2AV0<br />

6AV6 371-1DR16-2AV0<br />

6AV6 371-1DR06-2AX3<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/119<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC options<br />

WinCC/IndustrialDataBridge<br />

■ Overview<br />

The WinCC/IndustrialDataBridge option uses standard<br />

interfaces in order to connect the automation world with the<br />

world of IT and ensure two-way information flow. Typical<br />

examples of such interfaces are O<strong>PC</strong> in the field of automation<br />

and SQL database interfaces in the world of IT.<br />

For example, SIMATIC WinCC with its O<strong>PC</strong> DA server<br />

interface is the data source and an external database is the<br />

data destination.<br />

In addition to access to WinCC variables, access to<br />

messages, process values and user archive data (in the<br />

WinCC database) is also supported.<br />

As a stand-alone application with its standard interfaces,<br />

such as O<strong>PC</strong> DA and OLE-DB, WinCC/IndustrialDataBridge<br />

can be also be used in conjunction with SIMATIC NET and<br />

SIMATIC WinAC, for example.<br />

Option from WinCC V6<br />

For versions below V7.0<br />

On a computer without a license for the WinCC basic system<br />

or a WinCC option, which is to be accessed in read/write<br />

mode by the option WinCC/IndustrialDataBridge,<br />

a WinCC Client Access License is required (see also "WinCC/<br />

Client Access License").<br />

4/120<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Benefits<br />

Connecting the automation level with the IT world<br />

Integration of systems from different manufacturers via a host<br />

of standard interfaces (including O<strong>PC</strong>, OLE-DB, Office<br />

formats)<br />

Simple configuration with standard software without<br />

programming and thus at low cost<br />

High-performance data transfer between several systems<br />

simultaneously<br />

■ Design<br />

The software comprises a configuration environment and a<br />

runtime environment. The different data interfaces are integrated<br />

via software modules. In each case, one module is required as<br />

the data source and one module as the data destination. The<br />

different modules can be combined in any way.<br />

The connections between data source and data destination are<br />

created in the configuration environment. In the runtime<br />

environment, the IndustrialDataBridge establishes the<br />

connection autonomously and transfers the data of the linked<br />

variables.<br />

■ Function<br />

IndustrialDataBridge establishes a link between the source<br />

and destination interfaces and transfers data on the basis of a<br />

change in value, once a configurable period of time has<br />

elapsed or when a specific event occurs.<br />

IndustrialDataBridge exchanges data between automation<br />

systems from different vendors, e.g. via O<strong>PC</strong>. The connection<br />

of O<strong>PC</strong> servers via IndustrialDataBridge enables<br />

communication between a variety of devices, data sources<br />

and data destinations. The O<strong>PC</strong> international interface<br />

standard is the key to open systems both now and in the<br />

future. Thanks to IndustrialDataBridge, O<strong>PC</strong> data exchange<br />

can already be supported.<br />

WinCC supports access to variables, tag logging, alarm<br />

logging and user archive data.<br />

Storage of process data in Office formats such as Excel or<br />

Access. Databases can also be integrated for the archiving of<br />

larger aggregates.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SIMATIC WinCC options<br />

WinCC/IndustrialDataBridge<br />

One of the features of IndustrialDataBridge is a Send/Receive<br />

interface supporting data transfer to SIMATIC S5/S7 stations<br />

or other Send/Receive-compatible devices.<br />

IndustrialDataBridge enables SCADA and control systems<br />

from different vendors to be linked via the O<strong>PC</strong> interface.<br />

Communication via RFC1006 or Send/Receive is also<br />

supported.<br />

SQL databases are available as data destinations for<br />

production data acquisition. Data can be transferred from the<br />

data source on an event-driven basis with the O<strong>PC</strong> module or<br />

sent directly from the PLC with the Send/Receive module.<br />

Cyclic data archiving can be implemented via the<br />

O<strong>PC</strong> Data Access, WinAC ODK or Send/Receive data<br />

sources and the SQL database data destinations. On the<br />

database side, various transmission mechanisms are<br />

supported.<br />

Interfaces:<br />

The table below shows the possible data sources and<br />

destinations<br />

Provider (data sources) Consumer (data destinations)<br />

MS Access<br />

CSV, TXT<br />

MS SQL server<br />

MySQL ODBC (new)<br />

Oracle 8i, 9i and 10i<br />

O<strong>PC</strong> Data Access V2<br />

Send/Receive<br />

WinAC Send/Receive<br />

WinCC OLE DB<br />

WinCC UserArchive<br />

MS Access<br />

MS SQL server<br />

MySQL ODBC (new)<br />

Oracle 8i, 9i and 10i<br />

MS Excel<br />

O<strong>PC</strong> Data Access Server<br />

(internal)<br />

O<strong>PC</strong> Data Access V2<br />

Send/Receive<br />

WinAC Send/Receive<br />

WinCC UserArchive<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/121<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC options<br />

WinCC/IndustrialDataBridge<br />

■ Ordering data Order No. Order No.<br />

WinCC/IndustrialDataBridge<br />

WinCC/IndustrialDataBridge<br />

V7.0 SP1,<br />

V6.1, option for WinCC V6.2<br />

option for WinCC V7.0 SP1<br />

For data exchange with<br />

for data exchange with databases<br />

databases and O<strong>PC</strong> servers,<br />

and O<strong>PC</strong> servers, language<br />

language versions: German/<br />

versions: German/English<br />

English<br />

with 128 tags 6AV6 371-1DX07-0AX0<br />

with 128 tags 6AV6 371-1DX06-1AX0<br />

with 512 tags 6AV6 371-1DX07-0BX0<br />

with 512 tags 6AV6 371-1DX06-1BX0<br />

with 2048 tags 6AV6 371-1DX07-0CX0<br />

with 2048 tags 6AV6 371-1DX06-1CX0<br />

with 10000 tags 6AV6 371-1DX07-0DX0<br />

with 10000 tags 6AV6 371-1DX06-1DX0<br />

WinCC/IndustrialDataBridge<br />

WinCC/IndustrialDataBridge<br />

Power Pack V7.0<br />

Power Pack V6.1<br />

from 128 to 512 tags 6AV6 371-1DX07-0AB0<br />

from 128 to 512 tags 6AV6 371-1DX06-1AB0<br />

from 512 to 2048 tags 6AV6 371-1DX07-0BC0<br />

from 128 to 2048 tags 6AV6 371-1DX06-1AC0<br />

from 2048 to 10000 tags 6AV6 371-1DX07-0CD0<br />

from 128 to 10000 tags 6AV6 371-1DX06-1AD0<br />

WinCC/IndustrialDataBridge<br />

from 512 to 2048 tags 6AV6 371-1DX06-1BC0<br />

upgrade<br />

from 512 to 10000 tags 6AV6 371-1DX06-1BD0<br />

from V6.1 to V7.0 SP1 6AV6 371-1DX07-0XX4<br />

from 2048 to 10000 tags 6AV6 371-1DX06-1CD0<br />

4/122<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Overview<br />

Option for SIMATIC WinCC for managing data sets in user<br />

archives that contain related data.<br />

WinCC and its automation partners (e.g. a SIMATIC S7<br />

controller) write these data sets and exchange them if<br />

required.<br />

A license is only required for the server (or single-user<br />

system).<br />

The WinCC/User Archives option can also be used in the context<br />

of the WinCC/Web Navigator (see also WinCC/Web Navigator<br />

option).<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

HMI Software<br />

SIMATIC WinCC options<br />

WinCC/User Archives<br />

Storing and managing of any user data in data sets<br />

Flexible display using ActiveX controls<br />

Simple linking of data set fields to the process via direct tag<br />

linking<br />

Import/export functions for further processing with other tools<br />

(e.g. MS Excel)<br />

■ Function<br />

Input of parameter sets (e.g. operating parameters of a<br />

machine) in WinCC, storage of the sets in the user archive,<br />

and forwarding to the automation level<br />

Continuous acquisition of production parameters by the<br />

automation system and forwarding of the parameters to<br />

WinCC at the end of the shift<br />

Acquisition of batch data<br />

Specification of production parameters<br />

Management of warehousing data<br />

WinCC user archives are created and assigned data in a userfriendly<br />

way using a dedicated editor. Special ActiveX controls<br />

are used for displaying data from the user archives at runtime.<br />

Data sets and fields from user archives are linked to the process<br />

via direct tag linking.<br />

Import and export functions support read-in/out of data via<br />

external applications (e.g. MS Excel). Freely selectable filter<br />

criteria allow clear representation of data sets.<br />

WinCC provides functions for free organization of the data<br />

storage in the user archives that affect archives, data sets and<br />

fields. Archives can thus be generated, opened, closed, or<br />

reset, and data sets or field contents can be read, written or<br />

overwritten.<br />

Sequence archives can accommodate batch data, shift<br />

production data, or also product quality data, and meet legal<br />

obligations for verification thanks to gap-free recording.<br />

■ Ordering data<br />

WinCC/User Archives<br />

Order No.<br />

for WinCC V7.0 6AV6 371-1CB07-0AX0<br />

for WinCC V6.2 6AV6 371-1CB06-2AX0<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/123<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC options<br />

WinCC/Calendar Scheduler<br />

■ Overview<br />

Option for SIMATIC WinCC for managing events in a calendar.<br />

Setting WinCC variables or starting global scripts at defined<br />

times.<br />

A license is only necessary on the server (or single user<br />

system).<br />

4/124<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Simple operation, configuration and planning of events thanks<br />

to handling in the style of Microsoft Office Calendar<br />

Simple configuration of the actions by parameterization<br />

(execution of WinCC scripts or writing of WinCC tags at certain<br />

times)<br />

Configuration of recurring events taking account of<br />

configurable public holidays, vacation periods, and<br />

maintenance periods<br />

Secure operation of the plant taking account of different<br />

authentication levels<br />

Clear representation of events at runtime by means of<br />

Calendar Runtime Control<br />

Flexible use in all typical WinCC plant configurations, client/<br />

server, redundant systems, WebNavigator<br />

■ Function<br />

With the WinCC Calendar Scheduler, events and their<br />

associated actions can be configured in a user-friendly and<br />

clear way in an editor in WinCC Explorer.<br />

The events are represented in a calendar. The period<br />

represented can be freely selected. Recurring events can<br />

be defined as serial events with any desired exceptions.<br />

The events are displayed in a .Net control. The Calendar<br />

Scheduler is easy and intuitive to operate and supports<br />

drag & drop during configuration and runtime.<br />

■ Ordering data<br />

WinCC/Calendar Scheduler<br />

Order No.<br />

for WinCC V7.0 SP1 B 6AV6 372-1DC07-0AX0<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S


■ Overview<br />

Option for SIMATIC WinCC for notifying selected persons by<br />

e-mail in specified time slots<br />

Notification depends on events occurring in the WinCC Alarm<br />

System<br />

Escalation levels, i.e. Group 2 is only notified when nobody "on<br />

site" or from Group 1 has reacted within a specified time<br />

Final notification of all persons previously notified in<br />

connection with the specific event about the reaction that has<br />

taken place<br />

A license is only necessary on the server (or single user system).<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

HMI Software<br />

SIMATIC WinCC options<br />

WinCC/Event Notifier<br />

Simple operation, configuration and planning of notifications<br />

thanks to handling like the Microsoft Office Calendar<br />

Easy configuration of the notifications including support of the<br />

WinCC Runtime languages by connecting to the WinCC alarm<br />

system<br />

Configuration of recurring events taking account of<br />

configurable public holidays, vacation periods, and<br />

maintenance periods<br />

Secure operation of the plant taking account of different<br />

authentication levels<br />

Clear display and intuitive operation at runtime by means of<br />

Calendar Control<br />

Flexible use in all typical WinCC plant configurations, client/<br />

server, redundant systems, Web Navigator<br />

■ Function<br />

The WinCC Event Notifier enables the following to be configured<br />

in a clear and user-friendly manner via the Calendar Options<br />

Editor in the WinCC Explorer:<br />

The e-mail service<br />

for sending and receiving messages<br />

The notifications<br />

- by selecting configured messages in the WinCC Alarm<br />

System as well the setup and contents of the notification<br />

- by selecting the message blocks<br />

Contacts<br />

- by selecting predefined persons from the WinCC user<br />

administration.<br />

In a calendar it is then possible to select the persons to be<br />

notified within in the opened time slot from the existing contacts.<br />

If several persons or groups of persons are set up for the same<br />

time slot, escalation levels can be implemented by assigning<br />

different escalation times (= dead time before notification). The<br />

period represented by the calendar can be freely selected.<br />

Recurring events can be defined as serial events with any<br />

desired exceptions.<br />

The calendar can also be integrated as .Net Control in WinCC<br />

screens; the appearance of the calendar controls at runtime is<br />

configurable. Via the calendar control, you can create time slots<br />

at runtime with contacts who are then to be notified on occurrence<br />

of the configured events in the WinCC Alarm System. In<br />

addition, the calendar control allows the creation of new<br />

contacts by means of selection from the WinCC user<br />

management.<br />

The Event Notifier is easy and intuitive to operate and supports<br />

drag & drop during configuration and runtime.<br />

■ Ordering data<br />

WinCC/Event Notifier<br />

Order No.<br />

For WinCC V7.0 SP2 B 6AV6 372-1DD07-0AX0<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/125<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC options<br />

SIMATIC BATCH for WinCC<br />

■ Overview<br />

WinCC in connection with the SIMATIC BATCH product range<br />

offers a solution for the implementation of batch processes in<br />

accordance with ISA S88.<br />

SIMATIC BATCH for WinCC is of particular interest where<br />

different PLCs such as S7-400/300, S5 or non-<strong>Siemens</strong> PLCs<br />

are to be used in a BATCH system.<br />

SIMATIC BATCH for WinCC is offered as a bundle that<br />

includes the SIMATIC BATCH components as well as the<br />

WinCC components.<br />

SIMATIC BATCH for WinCC contains the software for<br />

SIMATIC BATCH including options, as well as for<br />

SIMATIC WinCC including options. These products are<br />

released for any combinations.<br />

- SIMATIC BATCH for WinCC includes the licenses<br />

SIMATIC BATCH Server (10 units *) ), SIMATIC BATCH CC,<br />

and SIMATIC BATCH Recipe.<br />

- All other SIMATIC BATCH and SIMATIC WinCC products<br />

require the purchase of the relevant license or licenses.<br />

*) Units are the number of subsystems that can be operated with this<br />

license.<br />

Current versions:<br />

SIMATIC BATCH for WinCC V7.1 SP1<br />

- WinCC V7.0 SP1<br />

- SIMATIC BATCH V7.1 SP1<br />

Configuration<br />

SIMATIC BATCH for WinCC<br />

■ Benefits<br />

PROCESS BUS<br />

SIMATIC BATCH for WinCC supports the user in the<br />

implementation of batch processes in accordance with<br />

ISA S88<br />

Modular architecture with flexible scalability and optimal<br />

adaptation to plant size and individual requirements,<br />

especially with regard to the use of PLCs such as<br />

SIMATIC S7-400/300, SIMATIC S5 and non-<strong>Siemens</strong> devices<br />

High availability via redundant system configurations provides<br />

protection against loss of batch data<br />

Cross-subsystem recipes with significant simplification of<br />

recipe management<br />

4/126<br />

S5-135U<br />

S7-300/400<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC BATCH for WinCC<br />

BASIC 10 Units<br />

3rd-party PLCs<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00263<br />

Hierarchical recipes in accordance with ISA S88.01 for the<br />

creation of recipes oriented toward process engineering<br />

Saving, archiving and comprehensive reporting of batch data<br />

Formula support<br />

Validation in accordance with 21 CFR Part 11 is significantly<br />

simplified by functions such as Audit Trail (change log),<br />

versioning of recipes, recipe operations and formulas,<br />

electronic signature and access protection.<br />

■ Application<br />

SIMATIC BATCH for WinCC has been designed for:<br />

Batch processes in the WinCC environment in accordance<br />

with ISA S88<br />

Users of S7-300, S7-400, S5 or non-<strong>Siemens</strong> controllers<br />

Users of <strong>ST</strong>EP5/<strong>ST</strong>EP7<br />

■ Design<br />

SIMATIC BATCH for WinCC ships with the following 3 software<br />

components and licenses:<br />

SIMATIC BATCH Server for 10 units<br />

SIMATIC BATCH Recipe system (Floating License)<br />

SIMATIC BATCH CC (Floating License)<br />

The following SIMATIC BATCH options can be used to expand<br />

or configure a plant or the relevant licenses can be purchased:<br />

SIMATIC BATCH Recipe system (Floating License)<br />

SIMATIC BATCH Planning (Floating License)<br />

SIMATIC BATCH CC (Floating License)<br />

SIMATIC BATCH Library<br />

SIMATIC BATCH Hierarchical Recipe<br />

SIMATIC BATCH Formula<br />

SIMATIC BATCH Power Packs (20, 40, 100, unlimited)<br />

The following basic products and SIMATIC WinCC options can<br />

be used to expand or configure a plant, or the relevant licenses<br />

can be purchased.<br />

SIMATIC WinCC RT/RC (incl. Power Packs)<br />

SIMATIC WinCC/Server<br />

SIMATIC WinCC/Redundancy<br />

SIMATIC WinCC/Archives (incl. Power Packs)<br />

SIMATIC Logon<br />

All previously listed software components including options of<br />

SIMATIC BATCH and SIMATIC WinCC are supplied with the<br />

product SIMATIC BATCH for WinCC. In addition, supplementary<br />

components for configuring the interfaces between WinCC and<br />

SIMATIC BATCH are included in the basic package. The use and<br />

compatibility of WinCC and SIMATIC BATCH is only guaranteed<br />

for the software versions that come with SIMATIC BATCH for<br />

WinCC.


■ Function<br />

The functions of SIMATIC BATCH for WinCC are based on the<br />

SIMATIC BATCH range of products. SIMATIC BATCH for WinCC<br />

includes the following licenses or functions:<br />

SIMATIC BATCH Server for 10 units<br />

SIMATIC BATCH CC (BATCH Control Center)<br />

SIMATIC BATCH Recipe System (recipe editor)<br />

It can be used to run a SIMATIC BATCH project with<br />

10 subsystems on a single-user station or a client/server combination<br />

(Batch Client and Batch Server).<br />

The capacity of the Server Basic Packages with 10 units can be<br />

expanded to 20, 40, 100 or unlimited units using SIMATIC<br />

BATCH Power Packs.<br />

SIMATIC BATCH CC offers powerful functions for the following<br />

tasks:<br />

Reading in and updating the plant data of the basic<br />

automation<br />

Defining user privileges for all functions, for clients or<br />

subsystems<br />

Definition of material names and codes<br />

Managing master recipes and starting the recipe editor<br />

Management of libraries with recipe elements (library<br />

operations)<br />

Editing of formula categories and management of associated<br />

formulas (parameter sets)<br />

Creation of batches with master recipes<br />

Starting of batch processing and controlling of batches<br />

Monitoring and diagnostics of batch processing<br />

Recording and archiving of recipes and batch data<br />

The hierarchical recipe structure is mapped on the plant module<br />

as follows:<br />

Recipe procedure for controlling the process or the<br />

production in a plant<br />

Partial recipe procedure for controlling a process step in a<br />

plant unit<br />

Recipe operation/function to implement the process<br />

engineering task/function in a technical facility<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SIMATIC WinCC options<br />

SIMATIC BATCH for WinCC<br />

SIMATIC BATCH Separation, Procedures and Formulas offers<br />

powerful functions for the following tasks:<br />

Quantity<br />

Temperature<br />

Time<br />

Salt<br />

Pepper<br />

Sugar<br />

The flexibility achieved by recipes which are independent of<br />

plant units can be increased even further if the procedure and<br />

parameter sets (formulas) are separated from one another.<br />

Various master recipes can be created by linking several<br />

formulas using a recipe procedure. This enables central modification<br />

of procedures. The formula structure is determined by the<br />

formula category defined by the user.<br />

Compatibility<br />

In respect of compatibility, please note that only the SIMATIC<br />

WinCC and SIMATIC BATCH versions included in the product<br />

package are compatible with each other. Only predecessor<br />

products of the product bundle SIMATIC BATCH for WinCC are<br />

upward compatible, not single components of the product range<br />

SIMATIC WinCC and SIMATIC BATCH.<br />

■ Integration<br />

Master Recipe #1<br />

Formula 1<br />

1 000 kg<br />

90 °C<br />

10 min<br />

Yes<br />

No<br />

100 g<br />

Formula 2<br />

500 kg<br />

<strong>80</strong> °C<br />

15 min<br />

Yes<br />

No<br />

150 g<br />

Formula 3<br />

900 kg<br />

95 °C<br />

12 min<br />

No<br />

Yes<br />

50 g<br />

Master Recipe #2 Master Recipe #3<br />

A detailed description of how to integrate SIMATIC Batch<br />

in WinCC appears in the interface description<br />

"SIMATIC BATCH Configuration Guide".<br />

■ Ordering data Order No.<br />

SIMATIC BATCH for WinCC 6ES7 657-1SA17-0YA0<br />

Software bundle for the creation<br />

of recipes and control of batch<br />

processes in accordance with<br />

ISA S88 based on<br />

SIMATIC BATCH.<br />

SIMATIC BATCH Server 10 units<br />

SIMATIC BATCH Recipe system<br />

(Floating License)<br />

SIMATIC BATCH CC (Floating<br />

License)<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/127<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC options<br />

WinCC/ChangeControl & WinCC/Audit<br />

■ Overview<br />

WinCC/ChangeControl is used to trace engineering changes<br />

in a tamper-proof long-term audit trail database, called the<br />

audit trail for short. All changes are automatically entered in<br />

the engineering system in the audit trail. This enables all the<br />

changes to be traced that have been made, to deduce the<br />

causes and minimize downtimes on the system.<br />

To begin tracing at a defined project status, a project version<br />

definition is provided that contains all data and files of a<br />

WinCC project version. The project version definition naturally<br />

provides the ability to reactivate earlier project versions.<br />

Document management is also provided, which manages and<br />

archives intermediate status for system graphics, reports or<br />

user files and stores change information of the user. An audit<br />

viewer with helpful filter functions can be used for quickly and<br />

simply evaluating the audit trail, exporting it to an Excel sheet<br />

or printing it out.<br />

WinCC/Audit includes the full functionality of<br />

WinCC/ChangeControl and is also used for tracing all<br />

operations. All operations are automatically recorded in the<br />

audit trail at RT.<br />

Licensing: To configure which change information from<br />

the project should be recorded in the audit trail, the<br />

WinCC/ChangeControl RC or WinCC/Audit RC package is<br />

required. "RC" stands for Runtime and Configuration.<br />

It is required on the station that is to be configured and also<br />

includes an RT license. For recording an audit trail, one<br />

WinCC/Audit RT license is required per WinCC station<br />

(Client/Server).<br />

The WinCC/Audit or WinCC/ChangeControl and SIMATIC<br />

Logon options support users in respect of plant validation and<br />

meet the requirements of FDA CFR 21 Part 11. A declaration<br />

of conformity (White Paper) offers proof of this.<br />

4/128<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Quick and easy traceability configuration<br />

Gap-free and automated recording of engineering changes<br />

and operator actions in an audit trail<br />

Reduction in plant downtimes thanks to fast analysis of the<br />

gap-free recorded audit trail information<br />

Logging of defined WinCC project status with all database<br />

information and files of the application<br />

Gap-free documentation of the project version definition<br />

procedures with version number, user and comments<br />

Complete tracing support by WinCC single and multi-station<br />

systems, single and multi-project solutions, Client/Server<br />

architecture<br />

Extensive reduction in engineering outlay in order to meet the<br />

requirements of FDA 21 CFR Part11 & EU 178/2002<br />

Compliance with the requirements of the Food and Drug<br />

Administration (FDA) for the food, beverages and tobacco<br />

industries<br />

■ Design<br />

WinCC/ChangeControl and WinCC/Audit consist of five<br />

components:<br />

The audit editor for configurating the audit trail content<br />

The project version definition for logging WinCC projects<br />

Document management for automatic archiving and<br />

versioning of WinCC plant mimics, scripts, reports, and<br />

project-specific documents, and the recording of the<br />

associated change information<br />

The audit viewer for visualizing, exporting and printing WinCC<br />

and WinCC flexible audit trails. The viewer is available as an<br />

executable program under Windows, as well as OCX with<br />

WinCC Runtime.<br />

The audit trail, which tracks all changes in respect of both<br />

engineering and plant operation in a separate SQL database.<br />

The audit trail can be set up as a central audit trail for a<br />

number of projects or even just for a single project.<br />

WinCC/ChangeControl and WinCC/Audit support both singleuser<br />

and multi-user systems, client/server architectures and<br />

even the WinCC redundancy system. No redundant audit trail is<br />

created however.


■ Function<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SIMATIC WinCC options<br />

WinCC/ChangeControl & WinCC/Audit<br />

■ Ordering data Order No.<br />

WinCC/ChangeControl<br />

WinCC/ChangeControl<br />

WinCC/ChangeControl is a functional subset of WinCC/Audit.<br />

WinCC/ChangeControl is for tracing engineering changes in the<br />

engineering phase or in online operation. All change data is<br />

recorded in an audit trail.<br />

For the configuration of the audit<br />

trail incl. RT<br />

V7.0, for WinCC V7.0 and B<br />

WinCC V7.0 SP1<br />

V6.2, for WinCC V6.2 and B<br />

6AV6 371-1DV27-0AX0<br />

6AV6 371-1DV26-2AX0<br />

There are two types of engineering changes:<br />

WinCC V6.2 SP2/SP3<br />

those that change the WinCC database or are executed WinCC/Audit RC<br />

through the WinCC Explorer, such as e.g. changes to tag<br />

management or creating a user group,<br />

For the configuration of the audit<br />

trail incl. RT<br />

and those<br />

limited to changing files, the so-called document<br />

administration.<br />

V7.0, for WinCC V7.0 and<br />

WinCC V7.0 SP1<br />

V6.2, for WinCC V6.2 and<br />

WinCC V6.2 SP2/SP3<br />

B<br />

B<br />

6AV6 371-1DV17-0AX0<br />

6AV6 371-1DV16-2AX0<br />

The document management manages system images, scripts<br />

and log layouts and customer-specific documents and stores<br />

respective intermediate versions as backups. All of these<br />

documents or files are subject to a change process, i.e.<br />

documents can be booked out for processing, booked in for<br />

finalization and intermediate versions can be retrieved from<br />

backup storage with a rollback function.<br />

WinCC/Audit RT<br />

Creation of the audit trail in RT<br />

V7.0, for WinCC V7.0 and<br />

WinCC V7.0 SP1<br />

V6.2, for WinCC V6.2 and<br />

WinCC V6.2 SP2/SP3<br />

B<br />

B<br />

6AV6 371-1DV07-0AX0<br />

6AV6 371-1DV06-2AX0<br />

The project version definition as a component of WinCC/<br />

ChangeControl archives WinCC projects and creates reproducible<br />

project status or defined start-time points for starting<br />

Upgrades<br />

V6.x to V7.0<br />

for WinCC/Audit RT B 6AV6 371-1DV07-0BX4<br />

tracing. An audit trail is also provided with information on who for WinCC/Audit RC or WinCC/ B 6AV6 371-1DV17-0BX4<br />

has created which project version or which version has been ChangeControl<br />

reproduced or deleted.<br />

V6.x to V6.2<br />

Configuring the audit trail, the project version definition and the<br />

document management is simple, quick and comfortable.<br />

for WinCC/Audit RC and WinCC/ B<br />

Audit RT<br />

6AV6 371-1DV06-2AX3<br />

The audit trail data is visualized from WinCC, as well as from<br />

WinCC flexible via the audit viewer, an executable program<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

under Windows. The data can also be evaluated with the audit<br />

viewer OCX in Runtime by WinCC however. Users select the ■ More information<br />

desired view of the audit trail information via filters or selection<br />

criteria and can export the data to an Excel file or print it on a<br />

printer. Audit trail information is tamper-proof and can thus not<br />

be modified or deleted. An export function can be used to swap<br />

out the audit trail to an XML file or to archive it.<br />

WinCC/Audit<br />

WinCC/Audit has all of the functionality of WinCC/ChangeControl<br />

and is also used for tracing user operations in RT operation.<br />

Tracing can be used for determining who, when and what conditions<br />

the machine has undergone. In addition to recording<br />

operator activities, the audit trail also records the starting and<br />

modifying of recipes or user logs. At specific objects or events,<br />

such as function buttons or sliders, the user can also record<br />

activities of an individual nature such as e.g. pressing a function<br />

button, moving sliders and other actions with a so-called audit<br />

entry function in the audit trail.<br />

A WinCC/ChangeControl RC license or a WinCC/Audit RC<br />

license is required for configuring the audit trail. One RT license<br />

is required for each station (client/server) to be monitored. One<br />

RC license always includes one RT license.<br />

Information about FDA can be found in a White Paper:<br />

Declaration of conformity of SIMATIC WinCC to<br />

FDA21 CFR Part 11.<br />

www.siemens.com/automation/hmi/html_76/products/software/<br />

wincc/fda01.htm<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/129<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC options<br />

SIMATIC Logon<br />

■ Overview<br />

■ Benefits<br />

■ Design<br />

The SIMATIC Logon Service can be used for the central user<br />

management of a number of WinCC stations. Operation in a<br />

Windows Workgroup or even in a domain is possible.<br />

4/130<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Function<br />

SIMATIC Logon (SL) for WinCC is a software option package<br />

SIMATIC Logon<br />

Users receive a unique user ID, user name and password.<br />

This information is stored encrypted at a central point (for<br />

SIMATIC Logon in the Windows user management). Functions<br />

such as changing the password, automatic logoff after a<br />

predefined time and lockout after several incorrect entries of a<br />

password ensure maximum security of operation.<br />

In the case of the SIMATIC Logon, user administration is<br />

integrated into the security system and user administration of<br />

MS Windows.<br />

To meet in particular the Food and Drug Administration (FDA)<br />

requirements for the pharmaceuticals and food processing<br />

industry, all user and administrator actions, such as log in, log<br />

supporting the central administration of all WinCC users on a out, password changes, incorrect password inputs, and creating<br />

plant-wide basis. The central user management with SL uses and deleting users, are recorded with timestamp in a secure<br />

the Windows mechanisms and is to be installed on all<br />

database or are available in the audit trail of WinCC/Change<br />

participating WinCC stations. The user management actions Control or WinCC/Audit.<br />

such as logging in and out are automatically supplied in the<br />

audit trail of WinCC/Audit and WinCC/ChangeControl by SL.<br />

The WinCC/Audit or WinCC/ChangeControl and<br />

SIMATIC Logon options support users in respect of plant<br />

validation and meet the requirements of FDA CFR 21 Part 11.<br />

A declaration of conformity (White Paper) offers proof of this.<br />

In addition, SIMATIC Logon allows setting up new users online,<br />

plant-wide and across applications, or blocking existing users.<br />

SIMATIC Logon also supports electronic signature.<br />

■ Ordering data Order No.<br />

Central, system-wide user management<br />

SIMATIC Logon V1.4-SP1 6ES7 658-7BX41-2YA0<br />

Conforms with the requirements of the Food and Drug<br />

Administration (FDA) for the pharmaceuticals and food<br />

Central user management for<br />

WinCC V6.2 and WinCC V7.0<br />

processing industry<br />

Runtime license for an operator<br />

station 1)<br />

1) SIMATIC Logon V1.4 included in scope of supply of WinCC V7.0<br />

■ More information<br />

Information on FDA can be found in a White Paper:<br />

Declaration of conformity of SIMATIC WinCC for<br />

FDA21 CFR Part 11.<br />

www.siemens.com/automation/hmi/html_76/products/software/<br />

wincc/fda01.htm


■ Overview<br />

WinCC/IndustrialX makes it easier to develop a solution for<br />

a visualization task by allowing customized objects to be<br />

standardized<br />

A license must be installed on each development computer<br />

(current version of Visual Basic must be installed on the<br />

development computer)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

HMI Software<br />

SIMATIC WinCC options<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

WinCC/IndustrialX<br />

Easy creation using configuration wizards<br />

Quick entry due to the use of standards: ActiveX technology,<br />

creating with the aid of Visual Basic<br />

Central creating and changing of object displays of the same<br />

type (typing) saves time and money<br />

Configuring of intelligent, sector-specific objects (graphic<br />

illustration and logical processing) with know-how protection<br />

Can be used in versatile ways: in WinCC screens and other<br />

Windows applications (e.g. Internet Explorer, Excel)<br />

Innovations of V7.0<br />

Support of Visual Studio 2005 (.NET)<br />

■ Application<br />

IndustrialX controls create standardized presentations and allow<br />

flexible customization to the requirements of a wide range of<br />

applications, e.g. applications in the chemical, glass or paper<br />

manufacturing industries.<br />

■ Function<br />

Configuring intelligent, industry-specific objects (graphic<br />

illustration and logical processing) with know-how protection<br />

Automatic object supply with WinCC data structures<br />

(templates)<br />

Creation of Web Navigator-compatible, customer-specific<br />

ActiveX components with active process data supply<br />

Integration into WinCC via structure names<br />

■ Ordering data Order No.<br />

WinCC/IndustrialX<br />

V7.0; for WinCC V7.0 and V6.x 6AV6 371-1EL17-0AX0<br />

4/131<br />

4


4<br />

HMI Software<br />

SIMATIC WinCC options<br />

WinCC/Open Development Kit (ODK)<br />

■ Overview<br />

WinCC/ODK (Open Development Kit)<br />

WinCC option for utilization of the exposed programming<br />

interfaces that can be used to access data and functions of<br />

the WinCC configuration and WinCC runtime system<br />

The interfaces are designed as "C-Application Programming<br />

Interface" (C-API)<br />

Scope of delivery:<br />

- CD-ROM with examples<br />

- Voucher for a one-day intensive workshop<br />

■ Benefits<br />

Individual system expansions via an open standard<br />

programming language<br />

Access to data and functions of the WinCC configuration and<br />

runtime system<br />

Development of your own applications and add-ons for the<br />

WinCC basic system<br />

Innovations of V7.0<br />

Support for Visual Studio 2005 (.NET)<br />

4/132<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Function<br />

The API functions are configuration and runtime functions, and<br />

include for example:<br />

MSRTCreateMsg: Creates a message<br />

DMGetValue: Gets the value of a variable<br />

PDLRTSetProp: Sets the object properties in a display<br />

They can be used in the following places:<br />

within WinCC, for example in global scripts or as part of<br />

C actions in the Graphics Designer,<br />

in Windows applications in the programming language C<br />

(the current version of Microsoft Visual C++ is necessary as a<br />

development environment for WinCC).<br />

■ Ordering data Order No.<br />

WinCC/ODK<br />

V7.0; for WinCC V7.0 and V6.x 6AV6 371-1CC07-0AX0<br />

WinCC/ODK upgrade<br />

to V7.0 6AV6 371-1CC07-0AX4


■ Overview<br />

WinCC<br />

Option<br />

WinCC<br />

Option<br />

WinCC<br />

Add-on<br />

WinCC<br />

Basic SW<br />

RC, RT<br />

WinCC<br />

Add-on<br />

WinCC<br />

Option<br />

WinCC<br />

Add-on<br />

WinCC Premium Add-ons – Solutions for all sectors and<br />

technologies<br />

The basic system is designed to be independent of any<br />

specific technology or industrial sector, to be modular and<br />

flexibly expandable and to permit not only simple single-user<br />

applications in machine construction, but also complex multiuser<br />

solutions or even distributed systems with several servers<br />

and clients in plant engineering. WinCC Premium Add-ons are<br />

supplementary products that have been created by competent<br />

partners working in the specifc sectors and technologies and<br />

represent interesting expansions for WinCC.<br />

WinCC Premium Add-ons are not IA (<strong>Siemens</strong> Industry<br />

Automation) products, but the products of partners who are<br />

committed to complying with certain quality features and<br />

boundary conditions. The Premium Add-ons are checked, for<br />

example, in the <strong>Siemens</strong> Test Center for their compatibility with<br />

the basic WinCC system and supported in the first instance by<br />

the central Hotline. As they are important application- and<br />

sector-specific add-on products for SIMATIC WinCC, they are<br />

marketed jointly by <strong>Siemens</strong> and the respective add-on<br />

suppliers. The WinCC Premium Add-on products can be found<br />

on the Internet (see Further Information) and in the "Online<br />

WinCC Premium Add-on <strong>Catalog</strong>".<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00175<br />

HMI Software<br />

WinCC add-ons and partner management<br />

WinCC add-ons and partner management<br />

Premium Add-ons for Connectivity:<br />

PM OPEN IMPORT system software<br />

for importing WinCC flexible archives into the WinCC system.<br />

PM OPEN EXPORT system software<br />

for exporting WinCC data to local storage media or storage<br />

media released in the network.<br />

PM OPEN TCP/IP system software<br />

permits bidirectional exchange of WinCC data (tags,<br />

messages) with one or more computers that communicate<br />

using the TCP/IP protocol.<br />

Historian CONNECT ALARM system software<br />

permits importing of messages and alarms from WinCC and<br />

WinCC flexible into the SIMATIC IT Historian.<br />

WinCC O<strong>PC</strong> Alarm & Event Client<br />

is used to transfer alarms and messages from any O<strong>PC</strong> A&E<br />

server complying with the specification to the WinCC signaling<br />

system.<br />

TOP Server/TOP Server UCON<br />

expands O<strong>PC</strong>-based the connection capability for WinCC &<br />

WinCC flexible Advanced (<strong>PC</strong> based runtime).<br />

Premium Add-on for process management:<br />

PM CONTROL system software<br />

is a recipe system for user-friendly generation and<br />

modification of recipes.<br />

PM QUALITY system software<br />

is an archive system for the administration of job and batchrelated<br />

production and process data.<br />

Premium Add-on for sector products:<br />

Library SENTRON PAC3200 for SIMATIC WinCC<br />

permits seamless integration of the SENTRON PAC3200<br />

multifunctional measuring instrument in WinCC.<br />

Sm@rtlib HVAC function library<br />

offers rule and component blocks for heating, climate and<br />

ventilation plants.<br />

ACRON for WinCC/<strong>PC</strong>S 7<br />

is used for long-term archiving and logging of process data for<br />

small to medium-sized plants, specifically in the water supply<br />

and treatment industry.<br />

Premium Add-on for configuration tools:<br />

DCC TranslationEditor<br />

for translating multilingual projects with in-built security,<br />

convenience and globalization features.<br />

Premium Add-on for diagnostics and maintenance:<br />

Management System Alarm Control Center<br />

for transmitting fault messages via various communication<br />

paths, such as GSM, LAN, e-mail.<br />

PM MAINT system software<br />

is a tool for the maintenance of production plants.<br />

PM ANALYZE system software<br />

for analysis of fault and operating messages, as well as<br />

process values.<br />

ShutDown WinCC system software<br />

terminates the WinCC Runtime software in the event of a<br />

power failure, minimizes plant downtimes, and increases data<br />

integrity.<br />

System diagnostics instrumentation and control<br />

for reading out the status of the instrumentation and control.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/133<br />

4


4<br />

HMI Software<br />

WinCC add-ons and partner management<br />

WinCC add-ons and partner management<br />

■ Overview (continued)<br />

■ More information<br />

Competent partners<br />

WinCC Competence Center<br />

With SIMATIC WinCC, you not only get excellent products to suit www.siemens.com/winCC/competencecenter<br />

your requirements, but we will also support you with selecting a<br />

partner for your automation solution. In our global network of<br />

<strong>Siemens</strong> Automation Solution Providers you will always find <strong>Siemens</strong> Solution Partner Automation<br />

competent partners in your neighborhood. In addition, we<br />

implement and support the <strong>Siemens</strong>-internal WinCC Compe-<br />

www.siemens.com/automation/solutionpartner<br />

tence Centers and the WinCC Professionals external system<br />

integrators on the basis of WinCC customer- and industry- WinCC Premium Add-on<br />

specific and economic solutions.<br />

www.siemens.com/winCC/addons<br />

WinCC Competence Centers<br />

Mannheim<br />

Emphasis on process management<br />

Sector-independent solutions and products in the fields:<br />

Production, environmental protection, maintenance and<br />

diagnostics<br />

Connectivity tools, system integration, connection to SAP R/3<br />

Support of FDA validation and WinCC ODK<br />

Support for advanced users with application of ODK and VBA<br />

Stuttgart<br />

Emphasis on production technology<br />

Solutions for maintenance management<br />

Web-based solutions with WinCC<br />

Erlangen<br />

Emphasis on process automation<br />

MES connectivity<br />

Plant information, maintenance, batch and quality<br />

management<br />

Web-based solutions with WinCC<br />

Customized database interfacing<br />

Nuremberg<br />

Solutions in the Oil & Gas, Metal & Mining, Pulp & Paper sectors<br />

Network and security<br />

Microsoft Certified<br />

Migration from COROS to WinCC<br />

Customized expansions also for WinCC flexible<br />

Web solutions<br />

Customer-specific workshops, e.g. training courses for VBS,<br />

VBA, web technologies à Web Server/Thin Client, DataMonitor<br />

à Webcenter Reports, Excel Workbook, and all WinCC topics<br />

as required by the customer (the latter with lead time)<br />

Barcelona<br />

Emphasis on production automation and logistics<br />

Solutions for integration of WinCC into MES and ERP<br />

Development of WinCC add-ons<br />

Nice<br />

Solutions in the food and beverages sector, pharmaceuticals<br />

and process engineering<br />

Batch processes<br />

Migration of SIMATIC TI, Teleperm M and <strong>PC</strong>S systems to<br />

WinCC<br />

Customized expansions<br />

FDA support<br />

Migration of TI systems<br />

Further information can be found in the Internet at:<br />

www.siemens.com/wincc/competencecenter<br />

4/134<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Overview<br />

SIMATIC WinCC Open Architecture is a SCADA system for<br />

visualizing and operating processes, production flows,<br />

machines and plants in all industrial sectors.<br />

Distributed systems enable the connection of up to 2048 autonomous<br />

SIMATIC WinCC Open Architecture systems via one<br />

network. Each subsystem can be configured either as singleuser<br />

or multi-user system, each of which may be redundant or<br />

non-redundant.<br />

SIMATIC WinCC Open Architecture relies throughout on object<br />

orientation in the case of process screens and the database<br />

structure. By means of the object-oriented properties and their<br />

consistent and considered use, the engineering process of<br />

SIMATIC WinCC Open Architecture customers changes. This<br />

means that high engineering cost savings can be achieved.<br />

Current version: SIMATIC WinCC Open Architecture V3.10<br />

Executes under:<br />

- Windows 7 Ultimate/Enterprise (32/64-bit)<br />

- Windows XP SP2/SP3 (32-bit)<br />

- Windows Server 2003 (32-bit)<br />

- Windows Server 2008 R2 (64-bit)<br />

- Red Hat Linux 5 (32/64-bit)<br />

- Open Suse 11.3<br />

- Sun Solaris 10<br />

- VMWare ESXi Server 4<br />

■ Benefits<br />

Efficient engineering and flexible plant expansion<br />

- Object orientation<br />

- Unlimited number of data points<br />

- Mass engineering<br />

- Multiple language support<br />

Freely scalable<br />

- From a small single-user system up to a networked,<br />

redundant high-end system<br />

- Distributed systems of up to 2048 servers<br />

Platform-independent<br />

- Available for Windows, Linux and Solaris<br />

Maximum fail-safety and availability<br />

- Hot standby redundancy<br />

- Disaster recovery system<br />

- SIL3 certification according to IEC 61508<br />

Platform for customized solutions<br />

- Quick and easy implementation of new processes<br />

- Swift adaptation of the control and visualization of the plant<br />

to current market requirements<br />

- Company-internal programming and in-house<br />

developments enable independence and protection of<br />

intellectual property<br />

- Structure of standardized solutions permits continuous use<br />

- Support of brand-labeling<br />

- Individual brand names for OEM developments<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SCADA System WinCC Open Architecture<br />

SCADA System WinCC Open Architecture<br />

Openness thanks to comprehensive drivers and interface<br />

options:<br />

- Modbus serial, Modbus Plus / RS485, RK512, TLS,<br />

Teleperm M, SSI driver, IEC 60870-5-101, -104, DNP3,<br />

SINAUT, PROFIBUS DP, PROFIBUS S7 + MPI, S7 TCP/IP,<br />

Modbus TCP/IP, Ethernet/IP, O<strong>PC</strong> DA Client & Server,<br />

O<strong>PC</strong> A&E Client & Server, O<strong>PC</strong> UA Client & Server (DA, AC),<br />

SNMP, BACnet, API, Cerberus<br />

Seamless traceability of system states by means of<br />

high-performance archiving:<br />

- Data archiving in value archives (internal database format)<br />

- Data archiving in an Oracle database<br />

Expandable by means of options and solution frameworks:<br />

- Options for quick and easy engineering<br />

- Options for increasing the availability<br />

- Options for clarity in distributed systems<br />

- Options for efficient maintenance management<br />

- Options for mobile operability<br />

- Options for efficient building automation technology<br />

- Framework for the integration of video management<br />

■ Application<br />

The process visualization and control system<br />

SIMATIC WinCC Open Architecture addresses applications with<br />

high demand for customer-specific adaptations, large and/or<br />

complex applications, as well as projects that demand special<br />

system requirements and functions.<br />

SIMATIC WinCC Open Architecture demonstrates its high<br />

performance in networked and redundant high-end control<br />

systems in particular. From the field level to the control station,<br />

from the machine to the company headquarters – integrated,<br />

high-performance communication is guaranteed.<br />

In every situation, a high level of availability, reliable information,<br />

fast interaction and user friendliness are guaranteed. Applications<br />

can also be changed without interrupting the process.<br />

Profitability, efficiency and safety are therefore always in<br />

equilibrium. SIMATIC WinCC Open Architecture displays its<br />

reliability in a wide range of business-critical applications.<br />

With SIMATIC WinCC Open Architecture, ideas can be<br />

quickly and easily converted into new applications.<br />

SIMATIC WinCC Open Architecture is open for independent<br />

in-house developments and also enables own product<br />

branding.<br />

Thanks to its special system properties,<br />

SIMATIC WinCC Open Architecture meets the highest demands<br />

especially in the case of traffic solutions, building management<br />

systems and supply systems (power, water, oil and gas, etc.).<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/135<br />

4


4<br />

HMI Software<br />

SCADA System WinCC Open Architecture<br />

SCADA System WinCC Open Architecture<br />

■ Design<br />

SIMATIC WinCC Open Architecture is available as a single-user<br />

runtime license, multi-user runtime license, Web Client license,<br />

and parameterization and development license.<br />

With SIMATIC WinCC Open Architecture the required license is<br />

determined, among other things, according to the number of<br />

inputs and outputs (I/O).<br />

An "I/O" refers to a data point element (DPE) whose content is<br />

exchanged either by means of drivers (e.g. S7 driver communicates<br />

with a PLC), with other SIMATIC WinCC Open Architecture<br />

servers (distributed systems), or with other software systems.<br />

Internal data point elements, i.e. DPEs without communication to<br />

the outside, are not counted for the licensing. The licenses are<br />

available either with unlimited number of I/O or with limitations of<br />

300 I/O, 1000 I/O, 5000 I/O or 100000 I/O.<br />

A multi-user license can be installed on several <strong>PC</strong>s – only the<br />

number of simultaneously active clients is counted.<br />

The Web Client enables the visualization and operation of<br />

process pictures over an exclusively HTTP connection between<br />

the server and the web client. The parameterization and development<br />

licenses extend a runtime license with the option of<br />

configuration and parameterization. They each require a server<br />

license.<br />

■ Function<br />

SIMATIC WinCC Open Architecture is a very modular<br />

SCADA system. The required functionalities are realized by<br />

specific, functional entities created for various tasks.<br />

In SIMATIC WinCC Open Architecture these units are called<br />

"Managers" – they are also distinct processes in software terms.<br />

WinCC OA Manager Task<br />

Event Manager (EV) The Event Manager (EV) is the processing<br />

center in WinCC OA. This unit provides a<br />

constantly updated image of all PowerTags<br />

in the memory. Each other functional unit<br />

(Manager) that wants to access the data<br />

receives it from the process image of the<br />

Event Manager and does not have to communicate<br />

directly with a controller. Conversely, a<br />

command from an operator station is initially<br />

set only as a value change in the process<br />

image of the Event Manager. The associated<br />

driver then forwards it to the corresponding<br />

target device (e.g. PLC) automatically.<br />

The Event Manager is a kind of central data<br />

distributor, in effect the communication center<br />

for WinCC OA. Furthermore, this Manager also<br />

carries out the alarm handling and can execute<br />

various arithmetic functions autonomously.<br />

Data Manager (DB) The Data Manager (DB) represents the link<br />

to database. On one hand, it involves the<br />

parameterization data of an application that is<br />

to be stored in such a database. On the other<br />

hand, it involves the historical recording of<br />

changes in values or alarms. If a user wishes<br />

to query historical data at a later date, then the<br />

Data Manager completes this request and not<br />

the database itself.<br />

4/136<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

WinCC OA Manager Task<br />

Driver Manager (D) The lowest level in a WinCC OA System is<br />

represented by the process connections,<br />

referred to in WinCC OA as drivers (D).<br />

These are special programs that handle the<br />

communication with the control and field level.<br />

Since numerous and very different forms of<br />

communication are possible with the PLCs or<br />

telecontrol nodes, there are several different<br />

drivers that can be selected. In very simple<br />

terms, the driver is a unit for converting a<br />

particular protocol into the internal communication<br />

form of WinCC OA. The driver reads the<br />

current states, measurement or counter values<br />

from the field and in the opposite direction it<br />

forwards commands and setpoints to the lowerlevel<br />

controllers (= the term "control" should be<br />

used here and below to represent all possible<br />

devices of the basic automation (PLC, DDC,<br />

telecontrol system, etc.)).<br />

Control Manager<br />

(CTRL)<br />

User Interface<br />

Manager (UI)<br />

WinCC OA has numerous options for<br />

implementing your own algorithms and<br />

processing. The two most important are the<br />

internal language control (CTRL) and the<br />

general application programming interface<br />

(API).<br />

Control is an extremely powerful scripting<br />

language. The processing is interpretative, so<br />

that no compilation is required. The syntax is<br />

almost identical with ANSI-C, with some<br />

modifications for simplification. This is a fully<br />

developed, procedural high-level language<br />

with multi-threading (= quasi-parallel<br />

processing of individual programs; the<br />

system itself carries out the processing check).<br />

The language offers a comprehensive function<br />

library for tasks of the control and visualization<br />

technology. Control can be used as a standalone<br />

process (Control Manager), for animation<br />

and user interface design or for standardized,<br />

data object-oriented processing functions.<br />

The API (WinCC OA API) represents the most<br />

powerful form of functional expansion. It is<br />

configured as a C++ class library and allows<br />

the software developer to implement individual<br />

functions as an independent, additional<br />

manager (forecast system, simulation, tools,<br />

proprietary databases, etc. ).<br />

The interface to the user is created by the<br />

User Interface Manager (UI). This comprises a<br />

graphic editor (GEDI), a database editor<br />

(PARA) or the general user interface of the<br />

application (Vision module). The User Interface<br />

serves to display values, issue commands or<br />

track alarms in the alarm list. Trends and<br />

reports are also usually part of the UI. From a<br />

programming viewpoint, the user interaction in<br />

WinCC OA is completely isolated from the<br />

background processing – this is merely a view<br />

of the data of the current process image or the<br />

history.


■ Function (continued)<br />

A WinCC OA System consists of function-specific units, the managers<br />

For special tasks such as redundancy, management for<br />

distributed systems, web server, reporting, simulation, COM<br />

etc., further managers are available.<br />

The powerful configuration functions contribute to a reduction of<br />

engineering and training overheads and lead to increased flexibility<br />

and operational reliability.<br />

Special functions Task<br />

Access to external<br />

databases<br />

Application<br />

Programming<br />

Interface (API)<br />

UI<br />

Userinterface<br />

Editor<br />

CTRL<br />

Control<br />

manager<br />

DB<br />

Database<br />

manager<br />

D<br />

Driver<br />

UI<br />

Userinterface<br />

Runtime<br />

EV<br />

Event<br />

manager<br />

D<br />

Driver<br />

UI<br />

Userinterface<br />

Runtime<br />

API<br />

API<br />

manager<br />

CON<br />

Connection<br />

to other<br />

systems<br />

D<br />

Driver<br />

Visualization, Operation<br />

UI<br />

GEDI<br />

PARA<br />

= Runtime<br />

= Graphical Editor<br />

= Database Editor<br />

Processing, Control<br />

Control = Script language<br />

Manager = Application<br />

API Programming<br />

Interface<br />

Process Image, History<br />

Event manager = Communication<br />

and Alarming<br />

Data manager, = History<br />

RDB<br />

Process Interface<br />

Driver: PLC, Field busses, DDC,<br />

Telemetry/RTU, Special drivers<br />

The database interfaces offer the possibility of<br />

access to external databases.<br />

Under Windows, the link is established via the<br />

ADO Standard. ADO (ActiveX Data Objects)<br />

is an interface developed by Microsoft for<br />

vendor-independent access to data sources of<br />

all types, primarily databases.<br />

The data source for ADO is an OLE DB<br />

Provider, although ODBC-compatible<br />

databases can also be addressed via an<br />

internal wrapper.<br />

Under Linux, the Qt library is used as an<br />

interface to relational databases. Access in<br />

this case is either direct via the native DB-API<br />

or via ODBC.<br />

The API offers a series of functions that enable<br />

WinCC OA to be extended with special<br />

managers. A manager means a program that<br />

communicates with the system by via a<br />

protocol defined by WinCC OA.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00463<br />

HMI Software<br />

SCADA System WinCC Open Architecture<br />

COM (Component<br />

Object Model)<br />

SCADA System WinCC Open Architecture<br />

Special functions Task<br />

This is a specification for the development of<br />

modular software components that can be<br />

used by each COM-compatible application.<br />

COM components can easily be integrated into<br />

such applications and can even be removed<br />

from an application during runtime. COM<br />

components can be programmed in a host of<br />

different languages, even though C++ is<br />

usually used for this purpose. The specifications<br />

OLE, ActiveX and DirectX are based on<br />

the COM technology.<br />

Control expansion Expansion that allows C++ functions to be<br />

added to the programming language.<br />

Panel topology/<br />

summation signal<br />

Redundancy<br />

(see figure next page)<br />

Generation of panel hierarchies/topologies in<br />

existing or new projects and automatic creation<br />

of summation signals of the alarm data points<br />

that are located in the panels of the topology.<br />

The failure safety in a redundant system is<br />

implemented by means of hot standby.<br />

Hot standby is a hardware-independent<br />

solution for high availability. This is a safety<br />

concept that consists of two interconnected<br />

server systems. Both servers are constantly<br />

in operation and are subject to the same<br />

functional loading (but only one server is ever<br />

active; the second compares the data with the<br />

primary unit at runtime). On the failure of one<br />

unit, an "on-the-fly changeover" takes place<br />

and the previously passive server assumes the<br />

leading role. This guarantees access to data or<br />

functions at all times.<br />

SMS Allows the sending and receiving of text<br />

messages with WinCC OA.<br />

Voice output Offers the user a further option for obtaining<br />

interactive information relating to process<br />

states.<br />

Encryption of panels<br />

and CTRL scripts/<br />

libraries<br />

Distributed systems<br />

(see figure next page)<br />

Allows your panels or scripts to be encrypted,<br />

thereby protecting your knowledge and work.<br />

Permits the coupling of two or more<br />

autonomous WinCC OA systems via a network.<br />

Each subsystem of a distributed system can<br />

be configured either as a single-user or<br />

multi-user system, each of which may be<br />

redundant or non-redundant. A sub-system<br />

in this context means a server on which an<br />

Event Manager is running, whereby in case<br />

of redundancy both redundantly operating<br />

servers are considered as one system.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/137<br />

4


4<br />

HMI Software<br />

SCADA System WinCC Open Architecture<br />

SCADA System WinCC Open Architecture<br />

■ Function (continued)<br />

Redundancy<br />

The diagram shows a detailed representation of the two<br />

computers Server 1 and Server 2. Server 1 is in the management<br />

mode (active) and Server 2 is in hot standby mode (passive).<br />

In the case of redundant operation, the UIs of both operator<br />

stations are connected to both Event Managers, however only<br />

the data of the active system is displayed on both UIs.<br />

The Event Manager of the passive system is restricted<br />

Distributed systems with WinCC OA<br />

4/138<br />

Operational station 1 Operational station 2<br />

Message direction<br />

CTRL<br />

Control<br />

manager<br />

DB<br />

Database<br />

manager<br />

UI<br />

Userinterface<br />

Runtime<br />

Process connection Process connection<br />

ACTIVE HOT-<strong>ST</strong>ANDBY<br />

Field devices<br />

or other connected systems<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

EV<br />

Event<br />

manager<br />

D<br />

Driver<br />

REDU<br />

Redundancy<br />

manager<br />

REDU<br />

Redundancy<br />

manager<br />

Event<br />

manager<br />

D<br />

Driver<br />

UI<br />

Userinterface<br />

Runtime<br />

Server 1 Server 2<br />

<br />

CTRL<br />

Control<br />

manager<br />

DB<br />

Database<br />

manager<br />

exclusively to communication with the Event Manager of the<br />

active system for comparison of the process data (it sends no<br />

data to the connected UIs or it discards messages from the<br />

drivers – this can be seen in the figure with the switches on the<br />

UIs or on the passive Event Manager).<br />

<br />

Operational station<br />

Operational station<br />

System 3 System 2<br />

<br />

WinCC OA<br />

Server<br />

(redundant)<br />

WinCC OA<br />

Server<br />

(stand alone<br />

system)<br />

<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

WinCC OA<br />

Server (multi-user system)<br />

Operational station<br />

Operational station<br />

Operational station<br />

System 1


■ Function (continued)<br />

Add-ons Task<br />

ETool The engineering tool ETool offers significant<br />

benefits in engineering in the case of<br />

combined WinCC OA and SIMATIC <strong>ST</strong>EP7/<br />

<strong>PC</strong>S7 projects. It provides a user-friendly<br />

engineering environment that permits easy,<br />

integrated and fast configuration on the basis<br />

of the WinCC OA mass parameterization.<br />

BACnet BACnet provides an integrated BACnetcompliant<br />

online/offline engineering solution for<br />

building automation technology, including<br />

object library. Designed for heating, ventilation<br />

and air-conditioning, lighting control and safety<br />

systems.<br />

S7 AdvancedLib<br />

object library<br />

Maintenance<br />

package<br />

The S7 AdvancedLib (AdvS7) is an industryindependent<br />

object library that permits the use<br />

and visualization of objects from the process<br />

control system (e.g. drives, valves, regulators,<br />

motors, etc.) in a project with WinCC OA and<br />

S7. In addition to the WinCC OA and<br />

AdvS7 license, the use of S7 AdvancedLib<br />

requires the use of the relevant library on the<br />

SIMATIC side.<br />

Includes the following functions: Operating<br />

hours counter, operating cycle counter and<br />

maintenance log.<br />

Scheduler Permits the creation, parameterization and<br />

management of time programs that allow the<br />

time and event-driven triggering of specific<br />

actions.<br />

Recipes WinCC OA recipes allow setpoints or<br />

commands for certain data point elements<br />

to be sent simultaneously. Based on<br />

"recipe types", which define the quantity of the<br />

data point elements concerned, recipes are<br />

created that send their values to the data point<br />

elements upon activation.<br />

GIS Viewer With the help of this viewer, standardized cards<br />

of a geo-information system (GIS) can be fully<br />

integrated in WinCC OA. Furthermore, it is<br />

possible to display all WinCC OA objects in the<br />

cards.<br />

Excel report Powerful report generator directly in<br />

Microsoft Excel. Templates can be created<br />

easily and directly in Excel. If a report has<br />

to be created over a defined period of time,<br />

the system accesses the template and<br />

automatically completes it with data from the<br />

WinCC OA process database. Reports can<br />

also be created, printed and saved on a<br />

time-controlled basis, without any need for<br />

user access. The Excel Report fully supports<br />

compression structures<br />

(AC - archive compression) of WinCC OA.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SCADA System WinCC Open Architecture<br />

Communication<br />

Center<br />

Video<br />

(see figure next page)<br />

SCADA System WinCC Open Architecture<br />

Add-ons Task<br />

Stands for modern alarm management/remote<br />

alerting and communication using the latest<br />

standards and various media.<br />

The Communication Center creates synergies<br />

by using the various interfaces for remote<br />

alerting via the control system.<br />

The voice output, text message and<br />

e-mail media are covered with the<br />

Communication Center.<br />

Enables the integration of a<br />

video management system in WinCC OA.<br />

Through the combination of SCADA and<br />

video monitoring in one system, the costs for<br />

separate video interfaces and the additional<br />

expense of maintenance and operation can be<br />

saved, and the period of training for operating<br />

personnel can also be reduced.<br />

HTTP server For displaying WinCC OA data via Intranet and<br />

Web.<br />

Authentication via<br />

Kerberos<br />

AMS (Advanced<br />

Maintenance Suite)<br />

Disaster Recovery<br />

System<br />

(see figure next page)<br />

A WinCC OA System can be exposed<br />

to a variety of attacks. An unauthorized<br />

WinCC OA System could set up a connection<br />

to the distribution manager or hackers could try<br />

to manipulate WinCC OA messages.<br />

In order to prevent espionage or other attacks,<br />

safe authentication was developed. The<br />

authentication based on Kerberos enables<br />

each WinCC OA component to verify the<br />

identity of another component.<br />

WinCC OA servers can verify the identity of the<br />

clients and clients can verify the identity of the<br />

servers. In addition, Kerberos ensures that<br />

messages are not modified during their transmission<br />

(capture-replay attacks are prevented).<br />

Furthermore, it is also possible to send<br />

messages in encrypted form.<br />

For the effective planning, administration,<br />

implementation and monitoring of maintenance<br />

work and faults. The processes are evaluated<br />

by means of statistics and reports are communicated.<br />

This system expands the simple redundancy to<br />

include a second redundant system, to which<br />

the system can switch over in the event of a<br />

fault (e.g. fire or explosion in the building of the<br />

primary system). By means of this additional<br />

local redundancy, the highest level of system<br />

stability is obtained.<br />

Pocket Client A "Thin Client" that is also suitable for the<br />

remote access via a mobile telephone or a<br />

PDA. Access is via a Web browser without any<br />

installation and provides a user interface even<br />

at those locations whose Internet connections<br />

offer very little bandwidth, as only the most<br />

essential data is transferred.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/139<br />

4


4<br />

HMI Software<br />

SCADA System WinCC Open Architecture<br />

SCADA System WinCC Open Architecture<br />

■ Function (continued)<br />

Network topology Video<br />

4/140<br />

WinCC OA<br />

active<br />

Server (A)<br />

Encoder<br />

Decoder<br />

Network<br />

video recorder<br />

WInCC OA<br />

Server<br />

Video Workstation<br />

Primary Server System (PSS)<br />

Database in<br />

Oracle Cluster<br />

WinCC OA<br />

Hot-Standby<br />

System<br />

Operating Interface<br />

with one or two<br />

interfaces<br />

Disaster Recovery System architecture with WinCC OA<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Control monitor<br />

(optional)<br />

Monitor 1<br />

Operator keyboard,<br />

mouse, joystick Video monitor 1<br />

TCP/IP<br />

connection<br />

WinCC OA<br />

passive<br />

Server (B)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Control commands<br />

Video monitor 2<br />

(optional)<br />

Control of monitor wall via POSA protocol<br />

WinCC OA<br />

active<br />

Server (C)<br />

Secondary Server System (SSS)<br />

WinCC OA<br />

Hot-Standby<br />

System<br />

Database in<br />

Oracle Cluster<br />

Cameras or<br />

crossbars<br />

Monitor wall<br />

(monitors 2 to n)<br />

WinCC OA<br />

passive<br />

Server (D)<br />

Field device or other<br />

connected systems like<br />

for example O<strong>PC</strong> UA


■ Integration<br />

Integration in automation solutions<br />

SIMATIC WinCC Open Architecture is an open SCADA system<br />

with comprehensive drivers and flexible options for connection<br />

to other external systems.<br />

Depending on the communications protocol and the bus<br />

physics used, specific drivers are used in each case:<br />

Serial protocols: RK512, 3964R, etc.<br />

Ethernet: Industrial Ethernet (S7), Modbus TCP<br />

(OpenModbus), Ethernet IP (AB), etc.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Coupling overview<br />

Protocol Description<br />

SIMATIC S7 via TCP/IP and MPI<br />

O<strong>PC</strong> Client<br />

Compatibility with the specifications DA 1.0<br />

(Data Access)<br />

and 2.05a<br />

Connection to inproc, local or remote server<br />

Connection with up to 20 servers at the<br />

same time<br />

Monitoring of the connection to the server<br />

and automatic reconnection if the<br />

connection is interrupted.<br />

Address browsing if supported by the<br />

server.<br />

Benefits of the CALL-R functionality for<br />

CALL-R servers (simplified parameter<br />

assignment)<br />

O<strong>PC</strong> Server (Data Corresponds to Data Access 2.05a<br />

Access)<br />

specification (reading/writing of online<br />

values).<br />

Is to be started as a manager just like<br />

other drivers.<br />

By means of data point groups, the items<br />

(DPEs) made available to other clients by<br />

the server can be defined.<br />

DPEs can be declared as readable<br />

(read-only access is permitted;<br />

Group O<strong>PC</strong>Read) or as writable items<br />

(Group O<strong>PC</strong>Write).<br />

Clients can browse the<br />

WinCC OA O<strong>PC</strong> Server hierarchically.<br />

O<strong>PC</strong> Alarms & Events O<strong>PC</strong> Alarms & Events<br />

(abbreviated to O<strong>PC</strong> A&E) is, in addition to<br />

Data Access, a further standard for<br />

performing central alarm management on a<br />

cross-vendor basis. O<strong>PC</strong> A&E is used to<br />

ensure the link to other control systems and<br />

the display of alarms/events in a hierarchical<br />

system.<br />

O<strong>PC</strong> UA<br />

The O<strong>PC</strong> UA client supports the<br />

(Unified Architecture) O<strong>PC</strong> UA standards Data Access and<br />

Alarms & Conditions.<br />

The O<strong>PC</strong> UA Server supports the<br />

O<strong>PC</strong> UA standards Data Access and<br />

Alarms & Conditions.<br />

Modbus TCP Modbus/TCP is based on the<br />

serial Modbus protocol, which was adapted<br />

for TCP/IP. The Modbus/TCP driver can be<br />

used simultaneously for Modbus/TCP or<br />

UNICOS.<br />

Serial: RK512/3964R Is used for interfacing a PLC via the<br />

3964R/RK512 protocol<br />

Cerberus Cerberus is a fire, intrusion and gas alarm<br />

system. The Cerberus driver guarantees<br />

communication to and from the central fire<br />

alarm systems and building security facilities<br />

in the event a fire, gas or intruder alarm.<br />

SSI Is used for the interfacing of SAT remote<br />

control systems. The data is exchanged via<br />

the LAN (Ethernet, IEEE <strong>80</strong>2.3); the frame<br />

formats used are the SSI formats defined by<br />

SAT. The SK 1703 telecontrol components<br />

with a suitable communication card (KE/ET)<br />

are supported.<br />

HMI Software<br />

SCADA System WinCC Open Architecture<br />

SCADA System WinCC Open Architecture<br />

Telecontrol systems: SINAUT, SSI (Ethernet),<br />

IEC 60870-5-101, IEC 60870-5-104, etc.<br />

Vendor-independent interfaces: O<strong>PC</strong> UA, etc.<br />

In SIMATIC WinCC Open Architecture, several drivers can<br />

be operated in parallel. These can be of the same type or<br />

also of different types. It is possible in a<br />

SIMATIC WinCC Open Architecture system to establish<br />

connections via the S7 protocol to a SIMATIC controller,<br />

via IEC 60870-5-104 to a telecontrol system, and via O<strong>PC</strong> DA<br />

to any O<strong>PC</strong> server at the same time.<br />

Protocol Description<br />

IEC 60870-5-101, -104 IEC drivers are standardized telecontrol<br />

drivers that can contain proprietary frames.<br />

IEC stands for International Electrotechnical<br />

Commission, the international standardization<br />

committee for electrical engineering.<br />

IEC 60870-5-104 for data exchange via<br />

TCP/IP<br />

IEC 60870-5-101 for serial connection<br />

DNP3 The DNP3 (Distributed Network Protocol 3)<br />

driver is an open, rugged and modern<br />

protocol which exhibits characteristics and<br />

strengths similar to the IEC driver. The<br />

transfer of any number of frames with<br />

different data types takes place between the<br />

WinCC OA System (Master) and the remote<br />

stations (Slave).<br />

SINAUT SINAUT (SIemens Network AUTomation) is a<br />

communication protocol for automated<br />

monitoring and control of remote process<br />

stations on the basis of SIMATIC S7. Communication<br />

takes place via TCP/IP.<br />

SNMP Manager &<br />

Agent<br />

BACnet over IP –<br />

driver<br />

Dynamic Logic –<br />

driver<br />

Applicom General<br />

Interface<br />

SNMP (Simple Network Management<br />

Protocol) is a protocol for monitoring network<br />

elements (servers, workstations, routers,<br />

switches, hubs, etc.) and their functions.<br />

SNMP Manager supports SNMP V1, V2, and<br />

V3<br />

SNMP Agent supports SNMP V1 and V2<br />

BACnet (Building Automation and Control<br />

Networks) is a standardized protocol for<br />

building automation and has been set by the<br />

ASHRAE (American Society of Heating,<br />

Refrigerating and Air-conditioning Engineers)<br />

as a guideline to provide a uniform and<br />

cross-company standard for data communication<br />

within and between building<br />

automation systems.<br />

The BACnet Standard 2004 is supported in<br />

accordance with the PIC list (see product<br />

documentation)<br />

The Dynamic Logic driver communicates<br />

with different Dynamic Logic devices via the<br />

"FSK outstation protocol".<br />

Applicom is, among other things, a manufacturer<br />

of I/O cards and software tools, with a<br />

wide range of applications in automation<br />

engineering. The Applicom products are<br />

compatible with many common fieldbus<br />

systems and communications components.<br />

Further drivers<br />

on request or<br />

via C++ API<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/141<br />

4


4<br />

HMI Software<br />

SCADA System WinCC Open Architecture<br />

SCADA System WinCC Open Architecture<br />

■ Technical specifications<br />

Type SIMATIC WinCC Open Architecture V3.10<br />

Operating system Windows 7 Ultimate/Enterprise (32/64-bit)<br />

Windows XP SP2/SP3 (32-bit)<br />

Windows Server 2003 (32-bit)<br />

Windows Server 2008 R2 (64-bit)<br />

Red Hat Linux 5 (32/64-bit)<br />

Open Suse 11.3<br />

Sun Solaris 10<br />

VMWare ESXi Server 4<br />

<strong>PC</strong> hardware requirements 1)<br />

Processor type Intel Pentium or equivalent<br />

Minimum Intel Pentium IV 1.6 GHz (or better) 2) 3)<br />

Recommended Client: Intel Pentium IV/Core2/i3,<br />

2 GHz 2) 3)<br />

Server: Intel Core i3 CPU Dual, 3 GHz 2)<br />

Server large system 4) : Intel(R) Core(TM)<br />

i5/i7 CPU Dual / Quad, 3 GHz 2) 3)<br />

RAM<br />

Minimum 512 MB 2)<br />

Recommended Client: 1 GB 2) 3)<br />

Server: 2 GB 2) 3)<br />

Server large system: 8 GB 2)<br />

Hard disk<br />

(available memory for<br />

installation)<br />

Minimum HD with 500 MB available 2)<br />

Recommended Server large system with local logging:<br />

SCSI LVD Controller, WIDE SCSI / LVD HDD<br />

or comparable storage system with at least<br />

500 MB of available space 2)<br />

Screen and graphics<br />

card (TrueColor)<br />

Minimum 1024 x 768 2)<br />

Recommended At least 12<strong>80</strong> x 1024 2)<br />

Mouse and keyboard 3-button mouse, German keyboard<br />

DVD drive for software installation<br />

Local power user rights for installation<br />

for operation<br />

1) For actual use in plants, the hardware requirements are largely<br />

dependent on the project size and the dynamic response of the<br />

process variables. Whenever possible, use rugged, high-quality<br />

hardware with corresponding functionalities such as redundant<br />

power supply units or RAID hard disks. WinCC OA supports dual and<br />

multi-processor mode and benefits significantly from the fact that<br />

each WinCC OA Manager can be assigned to one processor core<br />

as a system process. At the same time, however, it is important that<br />

the individual cores offer the highest possible performance<br />

(high clocking), since load-critical core processes such as the<br />

event manager run on exactly one core (for this reason, multi-core<br />

machines with low-clocked cores are unsuitable for WinCC OA).<br />

As for RAM, CPU and HDD, the usual rule applies: more is better<br />

2) System requirements generally only refer to WinCC OA Version 3.10<br />

under the supported versions of the Windows and Linux operating<br />

systems.<br />

3) A precondition for the minimum requirement is that the operating<br />

system used does not have any greater requirements itself<br />

4) With a large system it is essential that the system permits not only the<br />

highest data point numbers but also a high dynamic response.<br />

WinCC OA is ideally suited for use in very large distributed<br />

systems. The optimum design of such systems demands<br />

corresponding system knowledge of WinCC OA. Due to the<br />

event-oriented processing, individual design parameters can be<br />

increased or reduced as necessary in actual applications.<br />

4/142<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Type<br />

Functionality/quantity<br />

structure<br />

SIMATIC WinCC Open Architecture<br />

Number of alarms 150,000 2)<br />

Alarm text (number of<br />

characters)<br />

System-limited 1)<br />

Alarm log System-limited 1)<br />

Process values per alarm 1 process value + up to 32 alarm<br />

associated values per alarm<br />

Constant load of alarms,<br />

max.<br />

500/s 2)<br />

Message burst, max. 15,000/10 s every 5 min 2)<br />

Logs<br />

Log data points Max. 250,000 per server 2)<br />

Log types < 20 parallel logs, different retention period<br />

for each log<br />

Data storage format Oracle or file system<br />

Measured values per<br />

second, max.<br />

User log<br />

Server/single-user station: 7,000/s 2) 3)<br />

Logs System-limited 1)<br />

Type SIMATIC WinCC Open Architecture<br />

Table size<br />

Graphics system<br />

System-limited by ORACLE database<br />

Number of screens System-limited 1)<br />

Number of objects per<br />

screen<br />

System-limited 1)<br />

Number of controllable<br />

fields per screen<br />

System-limited 1)<br />

PowerTags < 750,000 per server 2)<br />

User management<br />

User accounts < 4096<br />

Configuration languages 2 (Ge, En)<br />

Runtime languages<br />

Multi-user system<br />

40 (of which 8 Asian)<br />

Server < 2048 2) 4)<br />

Number of clients < 244 per server 2) 5)<br />

1) Dependent on the available storage space<br />

2) Dependent on the system configuration and the system load<br />

(due to the event-oriented architecture, the system load is essentially<br />

determined by the change rates of the values to be processed)<br />

3) By means of high-performance hardware configuration (one archiving<br />

cluster and approx. 120 distributed systems that archive parallel<br />

values in the cluster): 200,000 archived value changes per second<br />

4) Physical limit:


HMI Software<br />

SCADA System WinCC Open Architecture<br />

SCADA System WinCC Open Architecture<br />

■ Ordering data Order No. Order No.<br />

SIMATIC WinCC Open Architecture<br />

system software V3.10<br />

Single user licenses, runtime<br />

Language/script versions: Ge,<br />

En; with license for:<br />

WinCC OA Server S 300 I/O<br />

License for single-user station<br />

with up to 300 I/O addresses of<br />

any type (bit, integer), alerting,<br />

extended trend, historical record,<br />

not expandable to more than one<br />

operator station, not expandable<br />

by means of add-ons, including<br />

O<strong>PC</strong> client<br />

D 6AV6 351-1AA31-0AA0<br />

WinCC OA Server M1 1000 I/O<br />

License for server and one singleuser<br />

station (expandable to<br />

several operator stations by<br />

means of clients) with up to<br />

1000 I/O addresses of any type,<br />

alerting, extended trend,<br />

historical recordings, including<br />

O<strong>PC</strong> client<br />

D 6AV6 351-1AB31-0AA0<br />

WinCC OA Server M2 3000 I/O<br />

License for server and one singleuser<br />

station (expandable to<br />

several operator stations by<br />

means of clients) with up to<br />

3000 I/O addresses of any type,<br />

alerting, extended trend,<br />

historical recordings, including<br />

O<strong>PC</strong> client<br />

D 6AV6 351-1AC31-0AA0<br />

WinCC OA Server L 5000 I/O<br />

License for server and one singleuser<br />

station (expandable to<br />

several operator stations by<br />

means of clients) with up to<br />

5000 I/O addresses of any type,<br />

alerting, extended trend,<br />

historical recordings, including<br />

O<strong>PC</strong> client<br />

D 6AV6 351-1AD31-0AA0<br />

WinCC OA Upgrade Server L<br />

Upgrade from server L by<br />

1000 I/O in each case<br />

D 6AV6 351-1AE31-0AA0<br />

WinCC OA Server XL<br />

100,000 I/O<br />

License for server and one singleuser<br />

station (expandable to<br />

several operator stations by<br />

means of clients) with up to<br />

100,000 I/O addresses of any<br />

type, alerting, extended trend,<br />

historical recordings, including<br />

O<strong>PC</strong> client<br />

D 6AV6 351-1AF31-0AA0<br />

WinCC OA Server UL unlimited D<br />

License for server and one singleuser<br />

station (expandable to<br />

several operator stations by<br />

means of clients) with unlimited<br />

number of I/O addresses of any<br />

type, alerting, extended trend,<br />

historical recordings, including<br />

O<strong>PC</strong> client<br />

6AV6 351-1AG31-0AA0<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

WinCC OA dongle<br />

Hardware dongle on the USB port<br />

for operation with a hardwareindependent<br />

license attached to<br />

the dongle, which can also<br />

extend the hardware-linked<br />

license of the operator station or<br />

server on a temporary basis<br />

6AV6 351-1AH31-0AA0<br />

WinCC OA on data medium<br />

WinCC OA software DVD - current<br />

version on disk<br />

Multi-user licenses, fixed<br />

clients<br />

Language versions: Ge, En; with<br />

license for<br />

D 6AV6 351-1AX31-0AA0<br />

WinCC OA Client M1 fix<br />

1000 I/O<br />

Additional permanently installed<br />

single-user station with all server<br />

operator station functionalities<br />

D 6AV6 351-1BB31-0AA0<br />

WinCC OA Client M2 fix<br />

3000 I/O<br />

Additional permanently installed<br />

single-user station with all server<br />

operator station functionalities<br />

D 6AV6 351-1BC31-0AA0<br />

WinCC OA Client L fix<br />

5000 I/O<br />

Additional permanently installed<br />

single-user station with all server<br />

operator station functionalities<br />

D 6AV6 351-1BD31-0AA0<br />

WinCC OA Upgrade Client<br />

L fix<br />

Upgrade of a client L fixed by<br />

1000 I/O each<br />

D 6AV6 351-1BE31-0AA0<br />

WinCC OA Client XL fix<br />

100,000 I/O<br />

Additional permanently installed<br />

single-user station with all server<br />

operator station functionalities<br />

D 6AV6 351-1BF31-0AA0<br />

WinCC OA Client UL fix<br />

unlimited<br />

Additional permanently installed<br />

single-user station with all server<br />

operator station functionalities<br />

Multi-user licenses<br />

floating clients<br />

Language/script versions: Ge,<br />

En; with license for:<br />

D 6AV6 351-1BG31-0AA0<br />

WinCC OA Client M1 floating<br />

1000 I/O additional operator<br />

station license with all server<br />

operator station functionalities.<br />

Client license can be installed on<br />

more than one <strong>PC</strong> – only the<br />

number of simultaneously active<br />

clients is counted<br />

D 6AV6 351-1CB31-0AA0<br />

WinCC OA Client M2 floating<br />

3000 I/O additional operator<br />

station license with all server<br />

operator station functionalities.<br />

Client license can be installed on<br />

more than one <strong>PC</strong> – only the<br />

number of simultaneously active<br />

clients is counted<br />

D 6AV6 351-1CC31-0AA0<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/143<br />

4


4<br />

HMI Software<br />

SCADA System WinCC Open Architecture<br />

SCADA System WinCC Open Architecture<br />

■ Ordering data Order No. Order No.<br />

WinCC OA Upgrade Client L<br />

floating<br />

Upgrade of a client L floating by<br />

1000 I/O each<br />

D 6AV6 351-1CE31-0AA0<br />

WinCC OA Client XL floating<br />

100,000 I/O additional operator<br />

station license with all server<br />

operator station functionalities.<br />

Client license can be installed on<br />

more than one <strong>PC</strong> – only the<br />

number of simultaneously active<br />

clients is counted<br />

D 6AV6 351-1CF31-0AA0<br />

WinCC OA Client UL floating<br />

Unlimited I/O additional operator<br />

station license with all server<br />

operator station functionalities.<br />

Client license can be installed on<br />

more than one <strong>PC</strong> – only the<br />

number of simultaneously active<br />

clients is counted<br />

Web Client<br />

Language versions: Ge, En; with<br />

license for:<br />

D 6AV6 351-1CG31-0AA0<br />

WinCC OA Web Client M1<br />

Web Client license for WinCC OA<br />

Server M1<br />

Only the number of simultaneously<br />

active Web Clients is<br />

counted. The Web Client enables<br />

the visualization and operation of<br />

process pictures over an exclusively<br />

HTTP connection between<br />

the server and the web client.<br />

Can be installed remotely on<br />

Windows, Linux and Solaris<br />

computers.<br />

Please note restrictions of the<br />

Web Client according to the<br />

Online Help<br />

D 6AV6 351-1DB31-0AA0<br />

WinCC OA Web Client M2<br />

Web Client license for WinCC OA<br />

Server M2<br />

Only the number of simultaneously<br />

active Web Clients is<br />

counted. The Web Client enables<br />

the visualization and operation of<br />

process pictures over an exclusively<br />

HTTP connection between<br />

the server and the web client.<br />

Can be installed remotely on<br />

Windows, Linux and Solaris<br />

computers.<br />

Please note restrictions of the<br />

Web Client according to the<br />

Online Help.<br />

D 6AV6 351-1DC31-0AA0<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

4/144<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

WinCC OA Web Client L<br />

Web Client license for WinCC OA<br />

Server L<br />

Only the number of simultaneously<br />

active Web Clients is<br />

counted. The Web Client enables<br />

the visualization and operation of<br />

process pictures over an exclusively<br />

HTTP connection between<br />

the server and the web client.<br />

Can be installed remotely on<br />

Windows, Linux and Solaris<br />

computers.<br />

Please note restrictions of the<br />

Web Client according to the<br />

Online Help.<br />

D 6AV6 351-1DD31-0AA0<br />

WinCC OA Upgrade Client L<br />

Upgrade of a Web Client L by<br />

1000 I/O each<br />

The Web Client enables the<br />

visualization and operation of<br />

process pictures over an exclusively<br />

HTTP connection between<br />

the server and the web client.<br />

Can be installed remotely on<br />

Windows, Linux and Solaris<br />

computers.<br />

Please note restrictions of the<br />

Web Client according to the<br />

Online Help<br />

D 6AV6 351-1DE31-0AA0<br />

WinCC OA Web Client XL<br />

Web Client license for WinCC OA<br />

Server XL<br />

Only the number of simultaneously<br />

active Web Clients is<br />

counted. The Web Client enables<br />

the visualization and operation of<br />

process pictures over an exclusively<br />

HTTP connection between<br />

the server and the web client.<br />

Can be installed remotely on<br />

Windows, Linux and Solaris<br />

computers.<br />

Please note restrictions of the<br />

Web Client according to the<br />

Online Help<br />

D 6AV6 351-1DF31-0AA0<br />

WinCC OA Web Client UL<br />

Web Client license for WinCC OA<br />

Server UL<br />

Only the number of simultaneously<br />

active Web Clients is<br />

counted. The Web Client enables<br />

the visualization and operation of<br />

process pictures over an exclusively<br />

HTTP connection between<br />

the server and the web client.<br />

Can be installed remotely on<br />

Windows, Linux and Solaris<br />

computers.<br />

Please note restrictions of the<br />

Web Client according to the<br />

Online Help<br />

D 6AV6 351-1DG31-0AA0


HMI Software<br />

SCADA System WinCC Open Architecture<br />

SCADA System WinCC Open Architecture<br />

■ Ordering data Order No. Order No.<br />

Parameterization and<br />

development license<br />

WinCC OA Para S 300 I/O<br />

Parameterization and development<br />

license for single-user<br />

station with max. 300 I/O<br />

addresses of any type (bit,<br />

integer), graphic editor with<br />

symbol catalog and ActiveX<br />

controls, user-friendly script<br />

development language, alerting,<br />

extended trend, historical<br />

recording. Requires corresponding<br />

server license.<br />

D 6AV6 351-1EA31-0AA0<br />

WinCC OA Para M1 1000 I/O<br />

Parameterization and development<br />

license for single-user<br />

station with max. 1000 I/O<br />

addresses of any type<br />

(bit, integer), graphic editor with<br />

symbol catalog and ActiveX<br />

controls, user-friendly script<br />

development language, alerting,<br />

extended trend, historical<br />

recording. Requires corresponding<br />

server license.<br />

D 6AV6 351-1EB31-0AA0<br />

WinCC OA Para M2 3000 I/O<br />

Parameterization and development<br />

license for single-user<br />

station with max. 3000 I/O<br />

addresses of any type<br />

(bit, integer), graphic editor with<br />

symbol catalog and ActiveX<br />

controls, user-friendly script<br />

development language, alerting,<br />

extended trend, historical<br />

recording. Requires corresponding<br />

server license.<br />

D 6AV6 351-1EC31-0AA0<br />

WinCC OA Para L 5000 I/O<br />

Parameterization and development<br />

license for single-user<br />

station with max. 5000 I/O<br />

addresses of any type<br />

(bit, integer), graphic editor with<br />

symbol catalog and ActiveX<br />

controls, user-friendly script<br />

development language, alerting,<br />

extended trend, historical<br />

recording. Requires corresponding<br />

server license.<br />

D 6AV6 351-1ED31-0AA0<br />

WinCC OA Upgrade Para L<br />

Upgrade of a Para L license by<br />

1000 I/O each<br />

D 6AV6 351-1EE31-0AA0<br />

WinCC OA Para XL 100,000 I/O<br />

Parameterization and development<br />

license for single-user<br />

station with max. 100,000 I/O<br />

addresses of any type<br />

(bit, integer), graphic editor with<br />

symbol catalog and ActiveX<br />

controls, user-friendly script<br />

development language, alerting,<br />

extended trend, historical<br />

recording. Requires corresponding<br />

server license.<br />

D 6AV6 351-1EF31-0AA0<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

WinCC OA Para UL unlimited<br />

Parameterization and development<br />

license for single-user<br />

station with unlimited number of<br />

I/O addresses of any type (bit,<br />

integer), graphic editor with<br />

symbol catalog and ActiveX<br />

controls, user-friendly script<br />

development language, alerting,<br />

extended trend, historical<br />

recording. Requires corresponding<br />

server license.<br />

B 6AV6 351-1EG31-0AA0<br />

WinCC OA ETool<br />

License for the use of the<br />

integrated ETool engineering<br />

environment, including the object<br />

library S7-BaseLib<br />

D 6AV6 351-1EJ31-0AA0<br />

WinCC OA API interface<br />

General<br />

Application programming<br />

interface for the integration of<br />

customer-specific managers or<br />

drivers. One license is required<br />

for each development workstation<br />

D 6AV6 351-1EK31-0AA0<br />

WinCC OA Custom Driver<br />

Extends a WinCC OA server<br />

license with the option of communication<br />

with a customer-specific<br />

driver. One license is required for<br />

each customer-specific driver.<br />

D 6AV6 351-1EL31-0AA0<br />

WinCC OA Custom Manager<br />

Extends a WinCC OA server<br />

license with the option of communicating<br />

with a customer-specific<br />

manager. One license is required<br />

for each customer-specific<br />

manager<br />

WinCC OA redundancy<br />

D 6AV6 351-1EM31-0AA0<br />

WinCC OA redundancy M1/M2/LD<br />

Extends a WinCC OA Server<br />

M1/M2/L with the option of<br />

bumpless switchover to a hot<br />

standby partner.<br />

The redundancy always requires<br />

two valid<br />

server licenses with redundancy<br />

option.<br />

6AV6 351-1FD31-0AA0<br />

WinCC OA Upgrade REDU L<br />

WinCC OA redundancy XL/UL;<br />

upgrade of the<br />

redundancy option for Server L<br />

with 1000 I/O each<br />

D 6AV6 351-1FE31-0AA0<br />

WinCC OA redundancy XL/UL<br />

Extends a WinCC OA Server<br />

XL/UL with the option of<br />

bumpless switchover to a hot<br />

standby partner.<br />

The redundancy always requires<br />

two valid server licenses with<br />

redundancy option.<br />

D 6AV6 351-1FG31-0AA0<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/145<br />

4


4<br />

HMI Software<br />

SCADA System WinCC Open Architecture<br />

SCADA System WinCC Open Architecture<br />

■ Ordering data Order No. Order No.<br />

WinCC OA distributed systems<br />

WinCC OA distributed systems D<br />

M1/M2<br />

Extends a WinCC OA Server<br />

M1/M2 with the Multiserver option<br />

and enables the connection of<br />

several autonomous WinCC OA<br />

systems. Each server requires<br />

one license.<br />

In the case of redundant servers,<br />

2 licenses are necessary for the<br />

redundant server pair.<br />

6AV6 351-1GC31-0AA0<br />

WinCC OA distributed<br />

systems L<br />

Extends a WinCC OA Server L<br />

with the Multiserver option and<br />

enables the connection of several<br />

autonomous WinCC OA systems.<br />

Each server requires one license.<br />

In the case of redundant servers,<br />

2 licenses are necessary for the<br />

redundant server pair.<br />

D 6AV6 351-1GD31-0AA0<br />

WinCC OA upgrade, distr.<br />

systems L<br />

Upgrade Multiserver option for<br />

each WinCC OA Upgrade<br />

Server L<br />

D 6AV6 351-1GE31-0AA0<br />

WinCC OA distributed systems D<br />

XL/UL<br />

Extends a WinCC OA Server XL/<br />

UL to include the Multiserver<br />

option. Enables the connection of<br />

several autonomous WinCC OA<br />

systems. Each server requires<br />

one license. In the case of<br />

redundant servers, 2 licenses are<br />

required for the redundant server<br />

pair.<br />

WinCC OA Disaster Recovery<br />

System<br />

6AV6 351-1GG31-0AA0<br />

WinCC OA Disaster Recovery<br />

System<br />

Allows the configuration of a<br />

remote backup control center.<br />

A DRS consists of 2 identical<br />

redundant server configurations<br />

with distributed systems and<br />

RDBs that must be ordered<br />

separately. Requires Oracle<br />

databases. Each server in the<br />

Disaster Recovery System<br />

requires one WinCC OA Disaster<br />

Recovery System option.<br />

D 6AV6 352-1AA31-0AA0<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

4/146<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC WinCC Open Architecture<br />

V3.10 communication<br />

WinCC OA TLS driver<br />

Driver in accordance with TLS<br />

regulations in connection with<br />

<strong>Siemens</strong> Commbox (see separate<br />

data sheet)<br />

D 6AV6 352-1BA31-0AA0<br />

WinCC OA Teleperm M<br />

Driver for Teleperm M Bus C275<br />

(requires an Acotex Comm Box)<br />

D 6AV6 352-1BB31-0AA0<br />

WinCC OA S7 TCP/IP driver<br />

TCP/IP for <strong>Siemens</strong> Industrial<br />

Ethernet<br />

D 6AV6 352-1BC31-0AA0<br />

WinCC OA Modbus TCP/IP<br />

driver<br />

TCP/IP for Schneider Modbus<br />

D 6AV6 352-1BD31-0AA0<br />

WinCC OA Modbus serial<br />

Serial driver for Schneider<br />

Modbus<br />

D 6AV6 352-1BE31-0AA0<br />

WinCC OA SSI driver<br />

Driver for SAT telecontrol components<br />

D 6AV6 352-1BF31-0AA0<br />

WinCC OA SNMP<br />

Driver SNMP – network<br />

monitoring (V2&V3)<br />

D 6AV6 352-1BG31-0AA0<br />

WinCC OA IEC 60870-5-104<br />

Driver IEC 60870-5-104<br />

D 6AV6 352-1BH31-0AA0<br />

WinCC OA IEC 60870-5-101<br />

Driver IEC 60870-5-101<br />

D 6AV6 352-1BJ31-0AA0<br />

WinCC OA DNP3 10 devices<br />

Driver DNP3 for connecting up to<br />

10 DNP3 devices<br />

D 6AV6 352-1BK31-0AA0<br />

WinCC OA DNP3 25 devices<br />

Driver DNP3 for connecting up to<br />

25 DNP3 devices<br />

D 6AV6 352-1BL31-0AA0<br />

WinCC OA DNP3 50 devices<br />

Driver DNP3 for connecting up to<br />

50 DNP3 devices<br />

D 6AV6 352-1BM31-0AA0<br />

WinCC OA DNP3 250 devices<br />

Driver DNP3 for connecting up to<br />

250 DNP3 devices<br />

D 6AV6 352-1BN31-0AA0<br />

WinCC OA DNP3 unlimited<br />

Driver DNP3 – unlimited license<br />

D 6AV6 352-1BP31-0AA0<br />

WinCC OA SINAUT 10 devices<br />

SINAUT driver for connecting up<br />

to 10 controllers<br />

D 6AV6 352-1BQ31-0AA0<br />

WinCC OA SINAUT 25 devices<br />

SINAUT driver for connecting up<br />

to 25 controllers<br />

D 6AV6 352-1BR31-0AA0<br />

WinCC OA SINAUT 50 devices<br />

SINAUT driver for connecting up<br />

to 50 controllers<br />

D 6AV6 352-1BS31-0AA0<br />

WinCC OA SINAUT 250 devices D<br />

SINAUT driver for connecting up<br />

to 250 controllers<br />

6AV6 352-1BT31-0AA0


HMI Software<br />

SCADA System WinCC Open Architecture<br />

SCADA System WinCC Open Architecture<br />

■ Ordering data Order No. Order No.<br />

WinCC OA SINAUT unlimited<br />

SINAUT driver – unlimited license<br />

D 6AV6 352-1BU31-0AA0<br />

WinCC OA RK512<br />

Driver for connection via 3964R /<br />

RK512 protocol<br />

D 6AV6 352-1CA31-0AA0<br />

WinCC OA PROFIBUS DP<br />

Driver PROFIBUS DP, an<br />

Applicom card is required<br />

D 6AV6 352-1CB31-0AA0<br />

WinCC OA PROFIBUS S7<br />

Driver PROFIBUS S7 + MPI,<br />

an Applicom card is required<br />

D 6AV6 352-1CC31-0AA0<br />

WinCC OA Modbus Plus /<br />

RS485<br />

Driver Modbus Plus +Modbus<br />

RS485, an Applicom card is<br />

required<br />

6AV6 352-1CD31-0AA0<br />

WinCC OA Omron FINS TCP-IP D<br />

Driver Omron FIN<strong>ST</strong>CP-IP, an<br />

Applicom card is required<br />

6AV6 352-1CE31-0AA0<br />

WinCC OA GE Fanuc SRTP<br />

Driver GE Fanuc SRTP, an<br />

Applicom card is required<br />

D 6AV6 352-1CF31-0AA0<br />

WinCC OA Allen Bradley<br />

Ethernet/IP<br />

Driver Allen Bradley Ethernet/IP,<br />

an Applicom card is required<br />

D 6AV6 352-1CG31-0AA0<br />

WinCC OA Cerberus<br />

Driver for connection with the<br />

<strong>Siemens</strong> DMS7000 / Cerberus fire<br />

alarm system. Communication is<br />

implemented via the C-Bus<br />

(CER-Ban) using the serial<br />

interface RS232 (MK 7022)<br />

D 6AV6 352-1CH31-0AA0<br />

WinCC OA O<strong>PC</strong> UA Server<br />

Driver for O<strong>PC</strong> UA DA and<br />

O<strong>PC</strong> UA AC Server<br />

Add-ons<br />

D 6AV6 352-1CJ31-0AA0<br />

WinCC OA BACnet driver +<br />

diagnostics<br />

License to use the BACnet Online<br />

Engineering environment<br />

consisting of BACnet driver,<br />

WinCC OA BACnet object library,<br />

including faceplates and<br />

WinCC OA BACnet Browser<br />

(max. 5,000 objects per server)<br />

D 6AV6 352-1DA31-0AA0<br />

WinCC OA BACnet Engineering D<br />

License to use the WinCC OA<br />

BACnet engineering environment<br />

consisting of WinCC OA BACnet<br />

Browser, WinCC OA EDE tool +<br />

EDE File Interface (requires<br />

WinCC OA engineering license)<br />

(max. 5,000 objects per server)<br />

6AV6 352-1DB31-0AA0<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

WinCC OA GIS Viewer<br />

GIS Viewer for displaying ESRI<br />

ShapesFiles. One license is<br />

required for each UI. Can be<br />

used in WinCC OA Client and<br />

Web Client. Maps are not<br />

included. Dynamization<br />

performed using Ctrl scripting.<br />

D 6AV6 352-1DC31-0AA0<br />

WinCC OA S7 AdvancedLib<br />

Runtime license for the use of the<br />

object library WinCC OA S7<br />

AdvancedLib, coordinated with<br />

the SIMATIC object library also<br />

supplied, which is free of charge<br />

until revoked. License required for<br />

each server.<br />

D 6AV6 352-1DD31-0AA0<br />

WinCC OA Maintenance<br />

Maintenance management for<br />

recording operating hours,<br />

switching cycles, alarm handling<br />

and notepad function. License<br />

required for each server.<br />

D 6AV6 352-1DE31-0AA0<br />

WinCC OA Scheduler<br />

Daily, weekly and monthly<br />

program, as well as individual<br />

non-periodic events with consideration<br />

of public holidays,<br />

assignment of priority and<br />

override function. License<br />

required for each server.<br />

D 6AV6 352-1DF31-0AA0<br />

WinCC OA Recipe<br />

Creation of any recipe types and<br />

recipes, acceptance of current<br />

process values as recipe,<br />

activation/download to data<br />

points, import and export<br />

(Microsoft Excel). License<br />

required for each server.<br />

D 6AV6 352-1DG31-0AA0<br />

WinCC OA RDB<br />

RDB Oracle connection for<br />

WinCC OA Server S-UL. Oracle<br />

licenses are not included.<br />

License required for each server.<br />

Excel report<br />

D 6AV6 352-1DH31-0AA0<br />

WinCC OA Report 1 UI<br />

1 parallel active Excel report<br />

process, Microsoft Excel is not<br />

included.<br />

D 6AV6 352-1FA31-0AA0<br />

WinCC OA Report 2 UI<br />

2 parallel active Excel report<br />

processes, Microsoft Excel is not<br />

included.<br />

D 6AV6 352-1FB31-0AA0<br />

WinCC OA Report 5 UI<br />

5 parallel active Excel report<br />

processes, Microsoft Excel is not<br />

included.<br />

D 6AV6 352-1FC31-0AA0<br />

WinCC OA Report 10 UI<br />

10 parallel active Excel report<br />

processes, Microsoft Excel is not<br />

included.<br />

D 6AV6 352-1FD31-0AA0<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/147<br />

4


4<br />

HMI Software<br />

SCADA System WinCC Open Architecture<br />

SCADA System WinCC Open Architecture<br />

■ Ordering data Order No. Order No.<br />

Communication Center<br />

WinCC OA CommCenter 1<br />

Basic package and additional<br />

dynamic voice output via<br />

telephone for 25 alarms,<br />

including Acapela speech engine<br />

D 6AV6 352-1GA31-0AA0<br />

WinCC OA CommCenter 2<br />

Basic package and additional<br />

dynamic voice output via<br />

telephone for 250 alarms,<br />

including Acapela speech engine<br />

D 6AV6 352-1GB31-0AA0<br />

WinCC OA CommCenter 3<br />

Basic package and additional<br />

dynamic voice output via<br />

telephone for 2500 alarms,<br />

including Acapela speech engine<br />

D 6AV6 352-1GC31-0AA0<br />

WinCC OA CommCenter 4<br />

Basic package and additional<br />

dynamic voice output via<br />

telephone for unlimited alarms,<br />

including Acapela speech engine<br />

Video management<br />

D 6AV6 352-1GD31-0AA0<br />

WinCC OA Video Light<br />

incl. 4 streams<br />

Possible video operator station<br />

configuration: 1 x quad image or<br />

2 dual images or 4 single images.<br />

Not expandable with further<br />

streams, redundancy not<br />

possible.<br />

D 6AV6 352-1HA31-0AA0<br />

WinCC OA Video Basic<br />

incl. 7 streams<br />

Possible video operator station<br />

configuration: 1 x quad image or<br />

2 dual images or 4 single images.<br />

Not expandable with further<br />

streams, redundancy not<br />

possible.<br />

D 6AV6 352-1HB31-0AA0<br />

WinCC OA Video Extension<br />

5 Streams<br />

Extends WinCC OA Video Basic<br />

by 5 streams<br />

D 6AV6 352-1HC31-0AA0<br />

WinCC OA Video Extension<br />

7 Streams<br />

Extends WinCC OA Video Basic<br />

by 7 streams<br />

D 6AV6 352-1HD31-0AA0<br />

WinCC OA Video Extension<br />

32 Streams<br />

Extends WinCC OA Video Basic<br />

by 32 streams<br />

D 6AV6 352-1HE31-0AA0<br />

WinCC OA Video Extension<br />

128 Streams<br />

Extends WinCC OA Video Basic<br />

by 128 streams<br />

D 6AV6 352-1HF31-0AA0<br />

WinCC OA Video Extension<br />

256 Streams<br />

Extends WinCC OA Video Basic<br />

by 256 streams<br />

D 6AV6 352-1HG31-0AA0<br />

WinCC OA Video Extension<br />

512 Streams<br />

Extends WinCC OA Video Basic<br />

by 512 streams<br />

D 6AV6 352-1HH31-0AA0<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

4/148<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

WinCC OA video driver SNK<br />

RS485 eneo<br />

Neo driver for controlling of neo<br />

pan-tilt cameras. One license is<br />

required for each WinCC OA<br />

Server.<br />

D 6AV6 352-1HJ31-0AA0<br />

WinCC OA video driver<br />

RS 485TVI<br />

Driver for controlling TVI pan-tilt<br />

cameras. One license is required<br />

for each WinCC OA Server.<br />

D 6AV6 352-1HK31-0AA0<br />

WinCC OA video driver SNK<br />

RS485 Funkwerk<br />

Driver for controlling Funkwerk<br />

pan-tilt cameras. One license is<br />

required for each WinCC OA<br />

Server.<br />

D 6AV6 352-1HL31-0AA0<br />

WinCC OA video driver SNK<br />

RS485 Globe<br />

Driver for controlling Globe pantilt<br />

cameras.<br />

One license is required for each<br />

WinCC OA Server.<br />

D 6AV6 352-1HM31-0AA0<br />

WinCC OA video driver SNK<br />

development<br />

Driver development for the control<br />

of pan-tilt cameras<br />

D 6AV6 352-1HN31-0AA0<br />

WinCC OA video driver for<br />

cameras with RCP+ and H264<br />

Drivers for controlling cameras<br />

with RCP+ and H264. One<br />

license is required for each<br />

WinCC OA Server.<br />

D 6AV6 352-1HP31-0AA0<br />

WinCC OA video driver development<br />

for encoder/decoder/<br />

host protocols<br />

D 6AV6 352-1HQ31-0AA0<br />

Driver development for controlling<br />

decoder/encoder/host protocols<br />

WinCC OA video driver Bosch<br />

IntKey<br />

Driver for controlling Bosch<br />

IntKey console controller.<br />

One license is required per<br />

server.<br />

D 6AV6 352-1HR31-0AA0<br />

WinCC OA Video driver development<br />

for console controllers<br />

Driver development for controlling<br />

console controllers<br />

D 6AV6 352-1HS31-0AA0<br />

WinCC OA video driver Bosch<br />

VRM (NVR)<br />

Drivers for controlling of Bosch<br />

video recording equipment / NVR.<br />

One license is required per<br />

server.<br />

D 6AV6 352-1HT31-0AA0<br />

WinCC OA video driver development<br />

for recording<br />

equipment / NVR<br />

D 6AV6 352-1HU31-0AA0<br />

Development for recording<br />

equipment/Driver development<br />

for video recorder equipment /<br />

NVR


HMI Software<br />

SCADA System WinCC Open Architecture<br />

SCADA System WinCC Open Architecture<br />

■ Ordering data Order No. Order No.<br />

HTTP server<br />

WinCC OA HTTP Server<br />

Forwarding of alarms, events and<br />

WinCC OA information to the<br />

Internet in HTML format including<br />

1 HTTP connection. The HTTP<br />

server is exclusively an HTTP<br />

server; HTTP clients represent<br />

alarms, events and other WinCC<br />

OA information in HTML pages.<br />

D 6AV6 352-1KA31-0AA0<br />

WinCC OA HTTP Server<br />

Extension5<br />

Extends the WinCC OA HTTP<br />

server by 5 HTTP connections.<br />

The HTTP server is exclusively an<br />

HTTP server; HTTP clients<br />

represent alarms, events and<br />

other WinCC OA information in<br />

HTML pages.<br />

D 6AV6 352-1KB31-0AA0<br />

WinCC OA HTTP Server<br />

Extension10<br />

Extends the WinCC OA HTTP<br />

server by 10 HTTP connections.<br />

The HTTP server is exclusively an<br />

HTTP server; HTTP clients<br />

represent alarms, events and<br />

other WinCC OA information in<br />

HTML pages.<br />

D 6AV6 352-1KC31-0AA0<br />

WinCC OA HTTP Server<br />

Extension25<br />

Extends the WinCC OA HTTP<br />

server by 25 HTTP connections.<br />

The HTTP server is exclusively an<br />

HTTP server; HTTP clients<br />

represent alarms, events and<br />

other WinCC OA information in<br />

HTML pages.<br />

Kerberos<br />

D 6AV6 352-1KD31-0AA0<br />

WinCC OA Secure<br />

Protection by Kerberos is calculated<br />

at an additional 40% of the<br />

license price for all protectable<br />

components in the project.<br />

Note: it is not possible to<br />

purchase only individual components<br />

with Kerberos protection.<br />

The surcharges for WinCC OA<br />

Secure are calculated in the<br />

detailed entries.<br />

AMS<br />

(Advanced Maintenance Suite)<br />

D 6AV6 352-1LA31-0AA0<br />

AMS Starter Package 20A/E<br />

This fully functional trial license<br />

valid for 90 days includes the<br />

AMS application as well as up to<br />

20 A/E = 20 checklists assigned<br />

to Alarm/Event DP. 1) 2)<br />

D 6AV6 352-1MA31-0AA0<br />

1) The basic price also includes the AMS Reports packages.<br />

2) AMS importer as well as 1 day of consulting for initial design by ETM<br />

Consultants (excluding travel expenses) and 5 hours of telephone<br />

support within 3 months after delivery.<br />

■ More information<br />

Further information can be found in the Internet at:<br />

www.siemens.com/wincc-open-architecture<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

AMS Entry 20 A/E<br />

The license includes the AMS<br />

application as well as up to<br />

20 A/E = 20 checklists assigned<br />

to alarm/event DP. 1) 2)<br />

D 6AV6 352-1MB31-0AA0<br />

AMS Small 100 A/E<br />

The license includes the AMS<br />

application as well as up to<br />

100 A/E = 100 checklists<br />

assigned to alarm/event DP. 1) 2)<br />

D 6AV6 352-1MC31-0AA0<br />

AMS Medium 1000 A/E<br />

The license includes the AMS<br />

application as well as up to<br />

1000 A/E = 1000 checklists<br />

assigned to alarm/event DP. 1) 2)<br />

D 6AV6 352-1MD31-0AA0<br />

AMS Large 5000 A/E<br />

The license includes the AMS<br />

application as well as up to<br />

5000 A/E = 5000 checklists<br />

assigned to alarm/event DP. 1) 2)<br />

D 6AV6 352-1ME31-0AA0<br />

AMS Upgrade Large<br />

The license contains an upgrade<br />

of the AMS Large 5000 A/E<br />

license with 1000 A/E = 1000<br />

checklists assigned to Alarm/<br />

Event DP.<br />

D 6AV6352-1MF31-0AA0<br />

AMS UL A/E<br />

The license includes the AMS<br />

application as well as an<br />

unlimited number of Alarm/Event<br />

DP checklist assignments. 1) 2)<br />

D 6AV6352-1MG31-0AA0<br />

AMS Client 2 UI<br />

Operating station license for<br />

simultaneous use of no more than<br />

2 parallel client sessions. The<br />

client license can be installed on<br />

more than one <strong>PC</strong> – only the<br />

number of simultaneously active<br />

clients is counted.<br />

D 6AV6 352-1MH31-0AA0<br />

AMS Client 5 UI<br />

Operating station license for<br />

simultaneous use of no more than<br />

5 parallel client sessions. The<br />

client license can be installed on<br />

more than one <strong>PC</strong> – only the<br />

number of simultaneously active<br />

clients is counted.<br />

D 6AV6 352-1MJ31-0AA0<br />

AMS Client 10 UI<br />

Operating station license for<br />

simultaneous use of no more than<br />

10 parallel client sessions. The<br />

client license can be installed on<br />

more than one <strong>PC</strong> – only the<br />

number of simultaneously active<br />

clients is counted.<br />

D 6AV6 352-1MK31-0AA0<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

4/149<br />

4


4<br />

HMI Software<br />

SIMATIC ProAgent process diagnosis software<br />

SIMATIC ProAgent<br />

■ Overview<br />

Process diagnosis software for quick and precise diagnosis of<br />

faults/errors in plants and machines for SIMATIC S7 and<br />

SIMATIC HMI<br />

Standardized diagnostics concept for various SIMATIC<br />

components: optimum interaction of <strong>ST</strong>EP 7 engineering tools<br />

and SIMATIC HMI<br />

Standardized user interface<br />

Process error diagnostics with ProAgent for WinCC flexible /ProAgent<br />

and with the <strong>ST</strong>EP 7 engineering tools<br />

Process error diagnostics with WinCC/ProAgent and the <strong>ST</strong>EP 7<br />

engineering tools<br />

4/150<br />

<br />

<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00367<br />

<br />

■ Benefits<br />

Integral component of Totally Integrated Automation (TIA):<br />

increases productivity, minimizes the engineering outlay,<br />

reduces the lifecycle costs<br />

ProAgent:<br />

- provides optimum support for plant and machine personnel<br />

in respect of troubleshooting and fault rectification<br />

- increases plant availability<br />

- reduces downtimes<br />

No further configuration overhead for diagnostics functionality<br />

Frees up PLC capacity with regard to memory and program<br />

execution time<br />

No special operator know-how is required thanks to clearly<br />

comprehensible indication of the cause of error<br />

■ Application<br />

Increased productivity is being achieved more and more<br />

by cutting costs. In this context, the focus is increasingly on<br />

maintenance. The emphasis here ist on rectifying faults as<br />

quickly and efficiently as possible. Ideally, the operating<br />

personnel should also perform part of the maintenance tasks.<br />

The operating personnel are on-site, they are familiar with the<br />

procedures and can intervene quickly. This saves time and<br />

reduces costs. It is precisely here that ProAgent can assist<br />

operating personnel in identifying faults quickly, in particular in<br />

the automotive and machine tool industries.<br />

In the event of a process fault, process fault diagnosis<br />

with SIMATIC ProAgent will provide information about the<br />

location and cause of that fault and support personnel with<br />

troubleshooting.<br />

The ProAgent solution has been optimized specifically for use<br />

with SIMATIC S7-300/S7-400 and SIMATIC WinAC. It can be<br />

used in combination with the S7-PDIAG, S7-GRAPH and<br />

S7-HiGraph 1) <strong>ST</strong>EP 7 engineering tools. The ProAgent option<br />

package features standard displays that are updated with<br />

process-specific data during runtime.<br />

1) Process diagnostics with S7-HiGraph in combination with<br />

TP/OP/MP 270/277, MP 370/377, and C7636 and <strong>PC</strong> RT systems.


■ Function<br />

Context-sensitive diagnostics initiation due to process error<br />

message<br />

Output of operands with symbols and comment<br />

Switching is possible between LAD, <strong>ST</strong>L and signal list<br />

Supporting fault rectification with direct process access when<br />

using the motion display<br />

Output of the faulty operands directly in the message<br />

including address, symbol and comment 1)<br />

Consistency test in RT:<br />

Inconsistent diagnostic units are marked with icons. This<br />

permits quick locating of faults regarding configured data in<br />

the commissioning phase.<br />

Direct, unit-related entry point in the diagnostic display from<br />

user displays by using ProAgent functions<br />

Unit or message-related entry to <strong>ST</strong>EP 7 (LAD/<strong>ST</strong>L/FD editor,<br />

S7-GRAPH, HW CONFIG (upon system error messages)),<br />

supported fully automatically 2)<br />

Unit or message-related entry to <strong>ST</strong>EP 7, supported fully<br />

automatically 3)<br />

Graphic display of step sequences (overview display) 4)<br />

1) In combination with TP/OP/MP 270/277, MP 370/377, C7 636,<br />

WinCC/ProAgent as of V6.0, and WinCC flexible /ProAgent<br />

2) WinCC/ProAgent as of V5.5 and as of WinCC flexible 2007/ProAgent<br />

on <strong>PC</strong> RT<br />

3) Only WinCC/ProAgent as of V5.5<br />

4) As of WinCC flexible 2007/ProAgent, WinCC/ProAgent as of V5.6 in<br />

combination with S7-GRAPH as of V5.1 (OCX is delivered as of<br />

S7-GRAPH 5.1)<br />

Standardized user interface with standard displays<br />

Message display<br />

Unit overview<br />

Diagnostics detail display<br />

Motion display<br />

Sequencer operating display<br />

The image contents displayed are related to the previously<br />

selected units or messages. This means that the proper contextsensitive<br />

diagnostics display can be called up based on a<br />

message or a selected technological unit.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SIMATIC ProAgent process diagnosis software<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC ProAgent<br />

Message display<br />

All of the existing process messages are shown in the message<br />

display. Context-sensitive branching to other diagnostic<br />

displays is also possible with a selected message. The<br />

operating personnel can also take the message directly from the<br />

erroneous operands and react immediately without having to<br />

perform any other operations on the HMI device. WinCC flexible<br />

permits this function on the Windows CE-based devices TP/OP/<br />

MP 270/277, MP 370/377, and on <strong>PC</strong> Runtime systems. The<br />

function is available as of version 6.0 for WinCC/ProAgent.<br />

Unit overview<br />

The units overview displays all technological units and the<br />

respective sub-units (system/machine components) in table<br />

form. In this display, the user is able to recognize, for example,<br />

which operating mode or which status the respective unit is in.<br />

The operating mode can be changed by the user if required.<br />

Faulty units are marked with attributes.<br />

4/151<br />

4


4<br />

HMI Software<br />

SIMATIC ProAgent process diagnosis software<br />

SIMATIC ProAgent<br />

■ Function (continued)<br />

Diagnostics detail display<br />

The diagnostic detail display shows the faulty operands at the<br />

time of origination of a process error. As an option, current status<br />

information can also be displayed. The diagnostics results are<br />

either displayed in a ladder diagram (LAD), statement list (<strong>ST</strong>L),<br />

or in a clearly arranged signal list overview. The output of the<br />

operands depends on the display format with symbols and<br />

comments from the S7 symbol table. Only the operands that<br />

cause the fault are displayed and marked with a highlighted<br />

attribute. Switching to a display that calls up the current status of<br />

all operands in the controller is also possible.<br />

Motion display<br />

The motion display is used for supported fault rectification. Every<br />

motion line contains a comment line that describes the motion<br />

(e.g. x-axis), two actions for implementing the motion, response<br />

concerning the actuation of a motion and information on the<br />

respectively achieved end positions (max. 16).<br />

The motion itself is controlled with softkeys on the side of<br />

SIMATIC Panels and Multi Panels. For time-critical motions, the<br />

actuation can be done directly through inputs of the controller<br />

(depending on the capabilities of the target hardware: 24 V<br />

direct keys, DP direct keys via PROFIBUS).<br />

4/152<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Sequencer operating display<br />

The sequencer operating display supports sequencer control.<br />

This makes functions such as initializing and acknowledging<br />

sequencers, activating/deactivating individual steps and<br />

operating mode settings possible analog to the status/control<br />

in S7-GRAPH.<br />

The steps are output to a list with step number/name. Attributes<br />

for identifying an active/faulty step give the operating personnel<br />

an overview of the current status of the step sequence.<br />

Sequencer diagnostic display<br />

WinCC flexible /ProAgent and WinCC/ProAgent 1) also offer<br />

capabilities for graphic monitoring and sequencer diagnostics.<br />

This gives the user the ability to monitor active/faulty steps as<br />

well as the fault cause, e.g. faulty transition conditions,<br />

simultaneously on the HMI device.<br />

1) WinCC/ProAgent as of V5.6 in combination with S7-GRAPH as of V5.1<br />

(OCX is delivered as of S7-GRAPH 5.1)


© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI Software<br />

SIMATIC ProAgent process diagnosis software<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC ProAgent<br />

■ Technical specifications<br />

WinCC/ProAgent WinCC flexible /ProAgent<br />

Interfaces<br />

Can be used in conjunction with SIMATIC S7:<br />

SIMATIC S7:<br />

programmable controllers: S7-300/S7-400; WinAC<br />

S7-300/S7-400; WinAC<br />

Types of connection SIMATIC S7 Protocol Suite:<br />

SIMATIC S7 Protocol Suite:<br />

Display units<br />

MPI, PROFIBUS DP, Industrial Ethernet, TCP/IP MPI, PROFIBUS DP,<br />

PROFINET IO, Industrial Ethernet, TCP/IP<br />

Standard images for: Standard displays for easy embedding in user<br />

displays,<br />

example project for MP 377<br />

Number of languages for<br />

online language selection<br />

Functionality<br />

3 (Ge/En/Fr) 5 (Ge/En/Fr/It/Sp)<br />

Modification of HMI diagnostics<br />

data management in RT<br />

WinCC/ProAgent V6.0 and higher No<br />

Unit overview Yes Yes<br />

Message display Yes Yes<br />

Sequencer operating display Yes Yes<br />

Diagnostics detail display Yes Yes<br />

Display<br />

<strong>ST</strong>L/LAD/signal list<br />

Yes/Yes/Yes Yes/Yes/Yes<br />

Display of operands with symbol<br />

and comment<br />

Yes Yes<br />

Criteria analysis<br />

Motion display<br />

When fault occurs/current status/can be archived When fault occurs/current status<br />

Number of viewable<br />

movements<br />

6 6<br />

Directions of motion 2 2<br />

Number of viewable<br />

end positions per movement<br />

Documentation<br />

16 16<br />

In electronic format<br />

Requirements<br />

Ge/En/Fr; included in scope of delivery Ge/En/Fr/It/Sp; included in scope of delivery<br />

HMI software WinCC V7.0<br />

(ProAgent V7.0 + SP2)<br />

WinCC flexible 2008<br />

Operating system:<br />

WinCC/ProAgent V7.0 + SP2:<br />

WinCC flexible / ProAgent 2008 + SP2:<br />

Configuration<br />

Windows Professional SP3, Windows 7 (32 bit) Windows XP SP3,<br />

Ultimate, Business, and Enterprise<br />

Windows 7 Professional,<br />

Ultimate, Enterprise<br />

Operating system<br />

WinCC/ProAgent V7.0 + SP2:<br />

WinCC flexible /ProAgent for SIMATIC Panels:<br />

Runtime<br />

Windows XP Professional SP3,<br />

WinCC flexible /ProAgent for WinCC flexible Runtime:<br />

Windows 7 (32 bit) Ultimate, Business and Enterprise, Windows XP SP3,<br />

Windows 2003 Server SP2, Windows 2008 Server SP2 Windows 7 Professional, Ultimate, Enterprise<br />

<strong>ST</strong>EP 7 V5.4 SP4 and higher V5.3 and higher<br />

S7-GRAPH V5.3 SP6 and higher V5.2 + SP3 and higher<br />

S7-PDIAG V5.3 SP3 and higher V5.1 and higher<br />

S7-HiGraph No V5.3 and higher<br />

Type of delivery<br />

(one license is required for each<br />

target hardware)<br />

CD-ROM / Runtime license Runtime license<br />

4/153<br />

4


4<br />

HMI Software<br />

SIMATIC ProAgent process diagnosis software<br />

SIMATIC ProAgent<br />

■ Ordering data Order No. Order No.<br />

SIMATIC WinCC/ProAgent<br />

Documentation<br />

Software option package for<br />

(must be ordered separately)<br />

process error diagnosis based<br />

SIMATIC HMI Manual Collection B 6AV6 691-1SA01-0AX0<br />

on S7 GRAPH V5 and higher and<br />

S7 PDIAG V5 and higher,<br />

functional enhancement for<br />

Electronic documentation,<br />

on CD-ROM<br />

SIMATIC WinCC,<br />

electronic documentation in<br />

English, French and German;<br />

functions and standard screens<br />

for use on a <strong>PC</strong><br />

(resolution 1024 x 768 pixels) and<br />

Panel <strong>PC</strong> 577/677/877 15"<br />

(resolution 1024 x 768 pixels) in<br />

English, French and German,<br />

runtime license (single license)<br />

WinCC version:<br />

5 languages (English, French,<br />

German, Italian, Spanish);<br />

contains: all currently available<br />

user manuals, manuals and<br />

communication manuals for<br />

SIMATIC HMI<br />

V7.0 SP2; for WinCC V7.0 SP2<br />

Upgrade<br />

6AV6 371-1DG07-0AX0<br />

to V7.0 SP2<br />

SIMATIC WinCC flexible<br />

/ProAgent<br />

Software option package for<br />

process error diagnosis based on<br />

S7 PDIAG V5.1 and higher,<br />

S7 GRAPH V5.2 + SP3 and<br />

higher; S7 HiGRAPH V5.3 and<br />

higher.<br />

Functional enhancement for<br />

SIMATIC WinCC flexible;<br />

electronic documentation in<br />

English, French, German, Italian<br />

and Spanish<br />

6AV6 371-1DG07-0AX4<br />

WinCC flexible /ProAgent for<br />

SIMATIC Panels<br />

Runtime license (Single<br />

License) executable on TP/OP/<br />

MP 270/277, Mobile Panel 277<br />

and MP 370/377<br />

D 6AV6 618-7DB01-3AB0<br />

WinCC flexible /ProAgent for<br />

WinCC flexible Runtime<br />

Runtime license (single license)<br />

D 6AV6 618-7DD01-3AB0<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

4/154<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


5/2 Industrial <strong>PC</strong><br />

5/4 Rack <strong>PC</strong><br />

5/10 SIMATIC I<strong>PC</strong>547D<br />

5/19 SIMATIC I<strong>PC</strong>547C<br />

5/27 SIMATIC I<strong>PC</strong>647C<br />

5/37 SIMATIC I<strong>PC</strong>847C<br />

5/48 SIMATIC Rack <strong>PC</strong> 647B<br />

5/58 Box <strong>PC</strong><br />

5/62 SIMATIC I<strong>PC</strong>227D<br />

5/70 SIMATIC I<strong>PC</strong>427C<br />

5/79 SIMATIC I<strong>PC</strong>627C<br />

5/88 SIMATIC I<strong>PC</strong>827C<br />

5/97 SIMATIC Box <strong>PC</strong> 827B<br />

5/105 SIMATIC Panel <strong>PC</strong><br />

5/109 SIMATIC HMI I<strong>PC</strong>227D<br />

5/116 SIMATIC HMI I<strong>PC</strong>477C<br />

5/126 SIMATIC HMI I<strong>PC</strong>577C<br />

5/134 SIMATIC HMI I<strong>PC</strong>677C<br />

5/141 SIMATIC Panel <strong>PC</strong> 677B<br />

5/149 <strong>PC</strong>-based Controller<br />

5/151 SIMATIC WinAC RTX<br />

5/161 SIMATIC WinAC RTX F<br />

5/171 SIMATIC WinAC ODK<br />

5/174 Embedded Controller<br />

5/176 EC31<br />

5/187 SIPLUS S7-modular embedded controller<br />

5/188 Expansion modules<br />

5/191 Embedded bundles/Software Packages<br />

5/192 Embedded Box <strong>PC</strong> bundles<br />

5/192 SIMATIC I<strong>PC</strong>227D bundles<br />

5/196 SIMATIC I<strong>PC</strong>427C bundles<br />

5/201 Embedded Panel <strong>PC</strong> bundles<br />

5/201 SIMATIC HMI I<strong>PC</strong>277D bundles<br />

5/205 SIMATIC HMI I<strong>PC</strong>477C bundles<br />

5/212 Software packages<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

5/214 Industrial Monitors and Thin Clients<br />

5/214 SIMATIC Flat Panels<br />

5/220 SCD monitors<br />

5/221 SCD desk monitors SCD 19101<br />

5/223 SCD monitors 1900<br />

5/226 SIMATIC Thin Client<br />

5/230 RMOS3 real-time operating system<br />

5/231 RMOS3 V3.50 real-time operating system<br />

5/238 RMOS3-GNU V3.0<br />

5/243 RMOS3-TCP/IP V3.0<br />

5/247 RMOS3-GRAPHX V1.0<br />

5/250 BSP SIMATIC I<strong>PC</strong> V3.1 for RMOS3<br />

5/255 Expansion components/<br />

accessories<br />

5/257 SIMATIC I<strong>PC</strong> CompactFlash<br />

5/258 SIMATIC I<strong>PC</strong> (Service) USB FlashDrive<br />

5/259 SINUMERIK 3.5" floppy disk drive, USB 1.1<br />

5/260 <strong>PC</strong> I/O<br />

5/266 Industrial USB Hub 4<br />

5/268 SIMATIC Panel <strong>PC</strong> Remote Kit<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5<br />

5/255 Expansion components/accessories<br />

5/271 SIMATIC I<strong>PC</strong> Image & Partition Creator<br />

5/273 SIMATIC I<strong>PC</strong> DiagMonitor<br />

5/275 SIMATIC I<strong>PC</strong> Remote Manager<br />

5/277 SIMATIC I<strong>PC</strong> BIOS Manager<br />

5/278 ADDM - Data Management<br />

5/2<strong>80</strong> DC UPS uninterruptible power supplies<br />

5/281 DC UPS with battery modules<br />

5/283 DC UPS module 6 A, 15 A<br />

5/284 DC UPS module 40 A,<br />

Battery module 24 V/1.2 Ah<br />

5/285 Battery module 24 V/2.5 Ah, 3.2 Ah<br />

5/286 Battery module 24 V/7 Ah, 12 Ah<br />

5/287 DC UPS with capacitors<br />

5/288 SITOP UPS500S<br />

5/289 Input and output devices<br />

5/290 T 2240/9<br />

5/291 T 2240/24<br />

5/292 T 2340/24<br />

5/293 2150<br />

5/294 2250<br />

5/295 SIMATIC <strong>PC</strong> keyboard<br />

5/296 IP65 membrane keyboard, desktop<br />

version<br />

5/297 IP65 membrane keyboard, 19" built-in<br />

version<br />

5/298 19" slide-in keyboard PS/2 with trackball<br />

5/299 SIMATIC <strong>PC</strong> mouse<br />

5/300 Operating channel extensions (active)<br />

5/301 MA<strong>ST</strong>ERGUARD power supply<br />

5/302 Communication – Industrial Ethernet<br />

5/302 Connection options to SIMATIC I<strong>PC</strong>s<br />

5/303 CP 1604<br />

5/305 CP 1616<br />

5/306 CP 1612 A2<br />

5/308 CP 1613 A2<br />

5/309 CP 1623<br />

5/310 CP 1628<br />

5/311 HARDNET IE S7-REDCONNECT<br />

5/313 SOFTNET for Industrial Ethernet<br />

5/315 SOFTNET PN IO<br />

5/317 O<strong>PC</strong> server for Industrial Ethernet<br />

5/319 S7 O<strong>PC</strong> Redundancy for Industrial Ethernet<br />

5/320 SNMP O<strong>PC</strong> server<br />

5/322 SINEMA E<br />

5/323 SINEMA server<br />

5/324 Communication – PROFIBUS<br />

5/324 Connection options to SIMATIC <strong>PC</strong>s<br />

5/325 CP 5603<br />

5/327 CP 5613 A2<br />

5/329 CP 5614 A2<br />

5/331 CP 5623<br />

5/333 CP 5624<br />

5/335 CP 5512<br />

5/336 CP 5611 A2<br />

5/337 CP 5621<br />

5/338 CP 5711<br />

5/339 SOFTNET for PROFIBUS<br />

5/341 O<strong>PC</strong> server for PROFIBUS<br />

5/343 S7 O<strong>PC</strong> Redundancy for PROFIBUS


5<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Industrial <strong>PC</strong><br />

Industrial <strong>PC</strong><br />

■ Overview<br />

Industrial <strong>PC</strong><br />

Our reliable and innovative industrial <strong>PC</strong>s are the optimal <strong>PC</strong><br />

hardware platform for <strong>PC</strong>-based Automation from <strong>Siemens</strong>.<br />

Rack <strong>PC</strong><br />

Rack <strong>PC</strong>s are flexible, fault-tolerant industrial <strong>PC</strong> systems for<br />

powerful yet compact applications using 19" technology.<br />

Box <strong>PC</strong><br />

SIMATIC Box <strong>PC</strong>s provide mechanical engineers, plant<br />

engineers and control cabinet makers with particularly rugged<br />

industrial <strong>PC</strong> systems for use in powerful yet compact applications.<br />

Panel <strong>PC</strong><br />

SIMATIC Panel <strong>PC</strong>s are suitable thanks to their high industrial<br />

compatibility for use in control cabinets, consoles and control<br />

panels, as well as directly on the machine. Typical areas of application<br />

can be found in both factory and process automation.<br />

Industrial monitors and Thin Clients<br />

Flexible operator input concepts can be implemented via Flat<br />

Panel monitors or Thin Clients. These are industry-standard LCD<br />

monitors with high-contrast displays that can be located up to<br />

30 m away from the <strong>PC</strong>, or low-cost, rugged Thin Clients that<br />

offer HMI functionality over the network in larger plants spread<br />

over wide areas.<br />

5/2<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Ruggedness and industrial compatibility for 24-hour<br />

continuous use in an industrial environment<br />

Compact, space-saving enclosure (Box <strong>PC</strong> and Panel <strong>PC</strong>)<br />

Suitable for installing in space-saving control cabinets, only<br />

500 mm deep (Rack <strong>PC</strong>)<br />

All-metal enclosure with a high degree of electromagnetic<br />

compatibility for use in industrial areas and in domestic,<br />

business and commercial environments and for a degree of<br />

protection up to IP65/NEMA 4<br />

The mounting position of the devices can be varied by means<br />

of wall, portrait or control cabinet mounting (Box <strong>PC</strong>), rail<br />

mounting (SIMATIC I<strong>PC</strong>427C or I<strong>PC</strong>227D only) and horizontal<br />

or vertical mounting position in the19" cabinet or with<br />

appropriate kit as an industrial tower <strong>PC</strong> (Rack <strong>PC</strong>).<br />

High resistance to shock/vibration thanks to special hard disk<br />

mountings, locked connectors, and card retainers<br />

Maintenance-free, due to design without hard disk and fans<br />

using SIMATIC CompactFlash Cards or solid-state drive<br />

(SIMATIC I<strong>PC</strong>427C and HMI I<strong>PC</strong>477C and SIMATIC I<strong>PC</strong>227D<br />

and SIMATIC HMI I<strong>PC</strong>277D)<br />

Service-friendly, modular device design for replacement of<br />

defective components<br />

Integrated industrial power supplies (according to NAMUR)<br />

for the safe power supply protected against system<br />

disturbances<br />

Attractive product design with dirt-repelling fronts and coated<br />

surfaces<br />

Dust protection thanks to a pressurized cooling concept,<br />

front-mounted fans and dust filters (Rack <strong>PC</strong>)<br />

Reduction in standstill times thanks to high system<br />

availability<br />

Assured 24-hour operation as a result of high-quality parts<br />

and components (high MTBF, speed-controlled fans)<br />

Efficient self-diagnostics for avoidance of potential failures<br />

(front status LEDs, SIMATIC I<strong>PC</strong> DiagMonitor diagnostics<br />

software for condition monitoring, local and remote)<br />

Minimum downtimes thanks to mirror disk systems and<br />

preventive data backup with SIMATIC I<strong>PC</strong> Image Creator and<br />

SIMATIC I<strong>PC</strong> BIOS Manager<br />

Restore CD/DVD for restoration of the delivery state<br />

Installed and activated Microsoft operating systems for time<br />

savings during installation


<strong>PC</strong>-based Automation<br />

SIMATIC Industrial <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Industrial <strong>PC</strong><br />

■ Benefits (continued)<br />

■ More information<br />

High degree of investment security for long-term automation<br />

concepts<br />

Availability of 3 to 5 years (at least 1.5 years for<br />

Notes on the scope of delivery<br />

Microsoft operating systems are pre-installed in an OEM version.<br />

Rack <strong>PC</strong> I<strong>PC</strong>547D)<br />

The scope of supply also includes:<br />

5-year repair and spare parts service (3 years for<br />

Rack <strong>PC</strong> I<strong>PC</strong>547D) after expiration of the active marketing<br />

period<br />

Long-term concepts are implementable and reduce future<br />

engineering costs<br />

System-tested SIMATIC software (WinCC, WinAC, etc.) and<br />

connection options for distributed I/Os via an optional<br />

PROFIBUS or PROFINET interface on board link the industrial<br />

<strong>PC</strong>s with Totally Integrated Automation<br />

Recovery CD for simple reinstallation of the operating system<br />

(not for Windows Embedded)<br />

Restore DVD (hard disk image) for fast and very easy<br />

restoration of the <strong>PC</strong> delivery status<br />

SIMATIC I<strong>PC</strong> documentation and driver CD<br />

Getting Started <strong>PC</strong> instructions in English/German/French/<br />

Spanish/Italian/Chinese<br />

Electronic manual on CD-ROM in English/German<br />

Certificates for worldwide marketing (cULus), the CE mark for Further information can be found on the Internet at:<br />

use in industrial areas and in domestic, business and<br />

commercial environments<br />

www.siemens.com/simatic-ipc<br />

Compatibility in hardware and software thanks to, for example,<br />

unchanged mechanical dimensions or the use of existing user<br />

Information material for ordering and for downloading is<br />

available on the Internet:<br />

software on all devices of the same generation<br />

Worldwide service and support<br />

(e. g. 24-hour SIMATIC Hotline)<br />

www.siemens.com/simatic/printmaterial<br />

■ Application<br />

SIMATIC I<strong>PC</strong>s are the ideal platform for <strong>PC</strong>-based Automation<br />

and are used both in the production and process industry, as<br />

well as in industry-oriented sectors such as traffic engineering,<br />

building management, warehouse systems.<br />

Typical applications include:<br />

Instrumentation and control tasks<br />

(e. g. with SIMATIC WinAC, also failsafe)<br />

Operator control and monitoring<br />

(e. g. with SIMATIC WinCC flexible, or WinCC)<br />

Data acquisition<br />

Image processing<br />

Communication, gateways<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

5/3<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

Rack <strong>PC</strong><br />

■ Overview<br />

Rack <strong>PC</strong>s are flexible, fault-tolerant industrial <strong>PC</strong> systems for<br />

powerful yet compact applications using 19" technology.<br />

Three device classes are available for various requirements:<br />

SIMATIC I<strong>PC</strong>547 – maximum performance at an attractive price<br />

SIMATIC I<strong>PC</strong>647 – maximum compactness combined with<br />

maximum industrial functionality<br />

SIMATIC I<strong>PC</strong>847 – maximum expandability and industrial<br />

functionality<br />

5/4<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Shared industrial functionality<br />

Maximum system performance for complex automation tasks<br />

and computationally intensive <strong>PC</strong> tasks in the industrial<br />

environment through use of Intel Core processors<br />

Designed for 24-hour continuous operation<br />

Monitoring and diagnostic functions (e. g. temperature, fan,<br />

watchdog)<br />

RAID1 configuration (mirrored drives), optionally in "hot swap"<br />

frames<br />

Compact dimensions for installation in control cabinets, only<br />

500 mm deep<br />

Dust protection thanks to overpressure ventilation concept<br />

with fan on the front and dust filter<br />

Lockable front panel or front door<br />

Service-friendly equipment design due to prepared telescopic<br />

rail mounting<br />

Universal implementation as an industrial workstation or<br />

server<br />

Operating system preinstalled and activated for fast startup<br />

Fast restoration of the delivery status of the HDD thanks to<br />

restore DVD<br />

High flexibility and expandability of components<br />

<strong>PC</strong>I and <strong>PC</strong>I-Express expansion slots<br />

Independent industrial product design


■ Overview (continued)<br />

SIMATIC I<strong>PC</strong>547D and SIMATIC I<strong>PC</strong>547C – maximum<br />

performance at an attractive price<br />

Maximum processor performance in maximum configuration<br />

without loss of power (throttling) at ambient temperatures of up<br />

to 40 °C<br />

Optional RAID5 configuration (striping with parity) in "hot<br />

swap" frames<br />

Redundant AC power supply, optional<br />

Low noise output thanks to controlled fans<br />

Status and alarm LEDs at the front for signaling critical system<br />

states<br />

Availability for at least 1.5 years<br />

Guaranteed spare parts availability for at least 3 years<br />

NEW with SIMATIC I<strong>PC</strong>547D:<br />

Intel Core i processors 2nd generation<br />

Hard disks with capacities up to 1 TB for large volumes of data<br />

Solid-State Drive (SSD), SLC optional<br />

SIMATIC I<strong>PC</strong>647C and SIMATIC Rack <strong>PC</strong> 647B – maximum<br />

compactness combined with maximum industrial<br />

functionality<br />

Maximum compactness due to 3 free <strong>PC</strong>I/<strong>PC</strong>I Express slots<br />

for installing long expansion cards and integrated interfaces<br />

for communication, e.g. integrated PROFIBUS/MPI or<br />

PROFINET interface<br />

High thermal stability up to 50 °C even at maximum processor<br />

performance<br />

High vibration/shock resistance thanks to special hard disk<br />

holders<br />

Service-friendly device design due, for example, to the<br />

replacement of filters/fans from the front without the need for<br />

tools, or opening of the enclosure with just one screw.<br />

Front LED concept for efficient self-diagnostics, e.g.<br />

monitoring of the hard disks in RAID1 configurators, fans or<br />

the status display for Ethernet, PROFINET and PROFIBUS.<br />

Integrated PROFIBUS DP/MPI or PROFINET interface<br />

(optional)<br />

High continuity of the components/design<br />

Motherboard developed and manufactured by <strong>Siemens</strong><br />

Availability for 3 to 5 years<br />

Guaranteed spare parts availability for at least 5 years<br />

NEW with SIMATIC I<strong>PC</strong>647C:<br />

Intel Core i processors<br />

Hard disks with capacities up to 500 GB for large data<br />

volumes<br />

ECC memory, optional<br />

Solid-State Drive (SSD), SLC optional<br />

Redundant AC power supply, optional (available soon)<br />

Enhanced server functionality (available soon):<br />

Hardware RAID <strong>PC</strong>Ie x8 controller, SAS hard disks in hot-swap<br />

frame with capacities up to 1 TB for large volumes of data<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Rack <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>847C – maximum expandability and industrial<br />

functionality<br />

Maximum expandability due to 11 free <strong>PC</strong>I/<strong>PC</strong>I Express slots<br />

for installing long expansion cards and integrated interfaces<br />

for communication, e. g. integrated PROFIBUS/MPI or<br />

PROFINET interface<br />

High thermal stability up to 50 °C even at maximum processor<br />

performance<br />

High vibration/shock resistance thanks to special hard disk<br />

holders<br />

Intel Core i processors<br />

Optional RAID5 configuration (striping with parity) in "hot<br />

swap" frames<br />

Enhanced server functionality (available soon):<br />

Hardware RAID <strong>PC</strong>Ie x8 controller, SAS hard disks in hot-swap<br />

frame with capacities up to 1 TB for large data volumes<br />

Redundant AC power supply, optional<br />

Hard disks with capacities up to 500 GB for large data<br />

volumes<br />

ECC memory, optional<br />

Solid-State Drive (SSD), SLC-optional<br />

Service-friendly device design due to, for example, the<br />

replacement of filters/fans from the front without the need for<br />

tools, or opening of the enclosure with just one screw.<br />

Front LED concept for efficient self-diagnostics, e. g.<br />

monitoring of the hard disks in RAID1 configurators, fans or<br />

the status display for Ethernet, PROFINET and PROFIBUS.<br />

Integrated PROFIBUS DP/MPI or PROFINET interface<br />

(optional)<br />

High continuity of the components/design<br />

Motherboard developed and manufactured by <strong>Siemens</strong><br />

3 to 5 years availability<br />

Guaranteed spare parts availability for at least 5 years<br />

5/5<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

Rack <strong>PC</strong><br />

■ Overview (continued)<br />

SIMATIC I<strong>PC</strong>547D SIMATIC I<strong>PC</strong>647C SIMATIC I<strong>PC</strong>847C<br />

Design<br />

19" rack<br />

Prepared for telescopic rails<br />

4 HU 2 HU 4 HU<br />

Horizontal/vertical installation<br />

19" mounting bracket can be<br />

removed from outside<br />

/ / - /<br />

Tower Kit (optional)<br />

General features<br />

-<br />

Processor Intel Core i7-2600 (4C/8T,<br />

Intel Core i7-610E<br />

Intel Core i7-610E<br />

3.40 GHz)<br />

(2C/4T, 2.53 GHz)<br />

(2C/4T, 2.53 GHz)<br />

Intel Core i5-2400 (4C/4T,<br />

Intel Core i5-520E<br />

Intel Core i5-520E<br />

3.10 GHz)<br />

(2C/4T, 2.4 GHz)<br />

(2C/4T, 2.4 GHz)<br />

Intel Pentium Dual Core G850 Intel Core i3-330E<br />

Intel Core i3-330E<br />

(2C/2T, 2.90 GHz)<br />

(2C/4T, 2.13 GHz)<br />

(2C/4T, 2.13 GHz)<br />

Main memory 1 GB, expandable up to 32 GB 1 GB, expandable up to 8 GB, 1 GB, expandable up to 8 GB,<br />

optional ECC<br />

optional ECC<br />

Slots for expansions<br />

4x <strong>PC</strong>I<br />

2x <strong>PC</strong>I<br />

7x <strong>PC</strong>I<br />

(all long)<br />

1 x <strong>PC</strong>I-Express x16<br />

1 x <strong>PC</strong>I-Express x16<br />

1 x <strong>PC</strong>I-Express x16<br />

1 x <strong>PC</strong>I-Express x16 (4 lanes)<br />

1 x <strong>PC</strong>I-Express x8<br />

(1 lane)<br />

or<br />

1x <strong>PC</strong>I<br />

1 x <strong>PC</strong>I-Express x8 (4-lane)<br />

3 x <strong>PC</strong>I-Express x4<br />

or<br />

7x <strong>PC</strong>I<br />

1 x <strong>PC</strong>I-Express x16<br />

1 x <strong>PC</strong>I-Express x16<br />

Onboard graphics 1 x DisplayPort<br />

1x DVI-I<br />

1x DVI-I<br />

1x DVI-I<br />

1 x VGA (via adapter cable, 1 x VGA (via adapter cable,<br />

1 x VGA (via adapter cable,<br />

optional)<br />

optional)<br />

optional)<br />

Graphic card (optional) <strong>PC</strong>I-Express x16<br />

<strong>PC</strong>I-Express x16<br />

<strong>PC</strong>I-Expressx16<br />

Operating system<br />

Without<br />

(2 x VGA or 2 x DVI-D)<br />

(2 x VGA or 2 x DVI-D)<br />

(2 x VGA or 2 x DVI-D)<br />

Preinstalled and activated, Windows XP Professional multi Windows XP Professional multi<br />

supplied on restore CD<br />

language (32-bit)<br />

language (32-bit)<br />

Windows 7 Ultimate multi language<br />

(32/64-bit)<br />

Windows 7 Ultimate multi language<br />

(32/64-bit<br />

Windows Server 2008 incl. 5 Client<br />

multi language (32-bit)<br />

Windows Server 2008 R2 incl.<br />

5 Client multi language (64-bit)<br />

3) )<br />

Windows Server 2008 incl.<br />

5 Client multi language<br />

Windows Server 2008 R2 incl.<br />

5 Client multi language (64-bit 3) Windows XP Professional multi<br />

language (32-bit)<br />

Windows 7 Ultimate multi language<br />

(32/64-bit<br />

)<br />

3) )<br />

Windows Server 2008 incl.<br />

5 Client multi language<br />

Windows Server 2008 R2 incl.<br />

5 Client multi language (64-bit 3) )<br />

Order separately - RMOS3 V3.50 RMOS3 V3.50<br />

Project-specific on request Linux 1)<br />

Linux<br />

Other<br />

1)<br />

Linux<br />

Other<br />

1)<br />

Interfaces<br />

Other<br />

PROFIBUS/MPI - 12 Mbit/s (CP 5611-compatible), 12 Mbit/s (CP 5611-compatible),<br />

optional<br />

optional<br />

PROFINET - 3 x RJ45 (CP 1616-compatible), 3 x RJ45 (CP 1616-compatible),<br />

optional<br />

optional<br />

Ethernet 2 x 10/100/1000 Mbit/s 2 x 10/100/1000 Mbit/s 2 x 10/100/1000 Mbit/s<br />

USB 2.0 (high current) 11 x, 2 of which at front, 1 x internal 7 x, 2 of which at front, 1 x internal 7 x, 2 of which at front, 1 x internal<br />

VGA<br />

DVI<br />

optional optional optional<br />

DisplayPort - -<br />

5/6<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


Available<br />

- Not available<br />

1) Suitable for specific Linux versions in accordance with the specifications<br />

of the <strong>Siemens</strong> manufacturer's declaration "Suited for Linux", see<br />

www.siemens.com/simatic-pc/suited-for-linux<br />

(Linux is a trademark of Linus Torvald)<br />

2) Restrictions when using DVD±R/RW and hard disks in swap frame.<br />

3) Available soon<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

■ Overview (continued)<br />

Drives<br />

SATA hard disks<br />

Internal installation<br />

Installation at the front in the<br />

swap frame<br />

-<br />

Internal installation in drive<br />

holder (shock and vibrationdamped)<br />

-<br />

RAID1/5 configuration<br />

Solid-State Drive (SSD), SLC<br />

Hard disks SAS<br />

/ / - /<br />

Installation at the front in the<br />

swap frame<br />

-<br />

RAID1/5 configuration with HW<br />

RAID controller <strong>PC</strong>I x 8<br />

Optical drives<br />

- / - / - /<br />

DVD-ROM<br />

DVD±R/RW<br />

AC power supply<br />

-<br />

Redundant (optional) 3)<br />

Ambient conditions 2)<br />

SIMATIC I<strong>PC</strong>547D SIMATIC I<strong>PC</strong>647C SIMATIC I<strong>PC</strong>847C<br />

Vibration/shock load<br />

during operation<br />

0.2 g / 1 g 0.5 g / 5 g 0.5g / 5g<br />

Ambient temperature during With maximum configuration: With maximum configuration: With maximum configuration:<br />

operation<br />

5 ... 40 °C<br />

5 ... 50 °C<br />

5 ... 50 °C<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Rack <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>547C SIMATIC Rack <strong>PC</strong> 647B<br />

Design<br />

19" rack<br />

Prepared for telescopic rails<br />

4 HU 2 HU<br />

Horizontal/vertical installation<br />

19" mounting bracket can be removed<br />

from outside<br />

/ / -<br />

Tower Kit (optional)<br />

General features<br />

-<br />

Processor Intel Core2 Quad Q9400 (4C/4T, 2.66 GHz) Intel Core2 Duo T7400 (2C/2T, 2.16 GHz)<br />

Intel Core2 Duo E8400 (2C/2T, 3.00 GHz) Intel Core2 Duo T5500 (2C/2T, 1.66 GHz)<br />

Intel Pentium Dual Core E5300 (2C/2T, 2.60 GHz) Intel Celeron M 440 (1C/1T, 1.86 GHz)<br />

Main memory 1 GB, expandable up to 16 GB 512 MB, expandable to 4 GB<br />

Slots for expansions<br />

4x <strong>PC</strong>I<br />

2x <strong>PC</strong>I<br />

(all long)<br />

1 x <strong>PC</strong>I-Express x16<br />

1 x <strong>PC</strong>I-Express x16 (PEG)<br />

1 x <strong>PC</strong>I-Express x8 (1 Lane)<br />

1 x <strong>PC</strong>I-Express x1<br />

or<br />

1x <strong>PC</strong>I<br />

1 x <strong>PC</strong>I-Express x4<br />

1 x <strong>PC</strong>I-Express x16 (PEG)<br />

Onboard graphics 1x VGA<br />

1x VGA<br />

1 x DVI-D (via adapter card, optional)<br />

1 x DVI-D (via adapter card, optional)<br />

Graphic card (optional) <strong>PC</strong>I-Express x16 (2 x VGA or 2 x DVI-D) <strong>PC</strong>I-Express x16 (2 x VGA or 2 x DVI)<br />

5/7<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

Rack <strong>PC</strong><br />

■ Overview (continued)<br />

Operating system<br />

Without<br />

Preinstalled/supplied on Restore CD Windows XP Professional multi language<br />

Windows Vista Ultimate multi language<br />

Windows 7 Ultimate multi language<br />

Windows Server 2003 R2 incl. 5 Client multi<br />

language<br />

Windows Server 2008 incl. 5 Client multi<br />

language<br />

Order separately - RMOS3 V3.50<br />

Project-specific on request Linux 1)<br />

Other<br />

Interfaces<br />

Available<br />

- Not available<br />

1) Suitable for specific Linux versions in accordance with the specifications<br />

of the <strong>Siemens</strong> manufacturer's declaration "Suited for Linux", see<br />

www.siemens.com/simatic-pc/suited-for-linux<br />

(Linux is a trademark of Linus Torvald)<br />

2) Restrictions when using DVD±R/RW and hard disks in swap frame.<br />

5/8<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>547C SIMATIC Rack <strong>PC</strong> 647B<br />

Windows XP Professional multi language<br />

Windows Vista Ultimate multi language<br />

Windows Server 2003 incl. 5 Client multi<br />

language<br />

Linux 1)<br />

Other<br />

PROFIBUS/MPI - 12 Mbit/s (CP 5611-compatible), optional<br />

PROFINET - 3 x RJ45 (CP 1616-compatible), optional<br />

Ethernet 2 x 10/100/1000 Mbit/s 2 x 10/100/1000 Mbit/s<br />

USB 2.0 (high current) 9 x, 2 of which at front, 1 x internal) 6 x, 2 of which at front<br />

VGA / audio 1 x / yes 1 x / yes<br />

DVI<br />

Drives<br />

SATA hard disks<br />

optional optional<br />

Internal installation<br />

Installation at the front in the swap frame<br />

-<br />

Internal installation in drive holder (shock<br />

and vibration-damped)<br />

-<br />

RAID1/5 configuration / / -<br />

SSD (Solid-State Drive)<br />

Optical drives<br />

- -<br />

DVD-ROM<br />

DVD±R/RW<br />

-<br />

Floppy<br />

AC power supply<br />

-<br />

Redundant (optional)<br />

Ambient conditions<br />

-<br />

2)<br />

Vibration/shock load<br />

during operation<br />

0.2g / 1g 0.5g / 5g<br />

Ambient temperature during operation With maximum configuration: 5 ... 40 °C With maximum configuration: 5 ... 50 °C


■ Benefits<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Rack <strong>PC</strong><br />

■ More information<br />

Rugged design<br />

Further information can be found on the Internet at:<br />

The overall design aims to achieve maximum safety for electro- www.siemens.com/simatic-pc<br />

magnetic, vibration and shock loads. A well-designed<br />

Information material can be ordered or downloaded from the<br />

pressurized ventilation concept ensures that even the maximum<br />

Internet:<br />

configuration can support high operating temperatures – and<br />

dust protection is included.<br />

www.siemens.com/simatic/printmaterial<br />

Service-friendly device design<br />

Particular attention was paid to making servicing extremely<br />

simple. <strong>PC</strong> components (e.g. slots, memory modules) are<br />

readily accessible. Fan filters and fans can be replaced without<br />

tools even when unit is built-in.<br />

Performance<br />

Thanks to the use of the latest generation of Intel Pentium Dual<br />

Core to Core i 2nd processors, SIMATIC Rack <strong>PC</strong>s are flexibly<br />

scalable for your application.<br />

System availability<br />

SIMATIC racks can be ordered in custom configurations and are<br />

supplied ready for use. The design's high system availability can<br />

be further extended by means of additional data backup options<br />

(e.g. RAID1 or RAID5 system, redundant power supply,<br />

SIMATIC I<strong>PC</strong> Image & Partition Creator) and efficient selfdiagnostics<br />

software (SIMATIC I<strong>PC</strong> DiagMonitor).<br />

Integrated interfaces<br />

Two onboard Gbit Ethernet interfaces are available for communication<br />

in the office world or at the control level. Integrated USB<br />

interfaces on the rear and front panels make connecting I/O<br />

devices from the <strong>PC</strong> world (e.g. external hard disks for mobile<br />

data backup, keyboard and/or mouse for operation) child's play.<br />

For advanced graphics applications, a spare <strong>PC</strong>I Express slot<br />

and a high-performance graphic card for the connection of two<br />

monitors are available.<br />

Expandability<br />

With up to 11 free <strong>PC</strong> slots, the SIMATIC Rack <strong>PC</strong> offers<br />

maximum leeway for expansions for installation in space-saving<br />

cabinets with a depth of just 500 mm.<br />

Continuity<br />

The SIMATIC Rack <strong>PC</strong> models can be ordered for a period of at<br />

least 1.5 years; spare parts remain obtainable for at least 3 years<br />

after active marketing is concluded. Long-term functionality of<br />

the hardware and software is also ensured. Long-term availability<br />

of <strong>PC</strong> components from the Intel embedded line ensures<br />

high investment protection.<br />

5/9<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>547D<br />

■ Overview<br />

The SIMATIC I<strong>PC</strong>547D is a rugged industrial <strong>PC</strong> in 19" rack<br />

design (4 HU).<br />

It offers:<br />

maximum performance<br />

attractive price<br />

Intel Core i technology<br />

5/10<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Maximum system performance for complex automation and<br />

visualization tasks<br />

State-of-the-art <strong>PC</strong> technology (e. g. Intel Core i processors<br />

2nd generation with Turbo Boost 2.0, hyper-threading and<br />

virtualization technology)<br />

Memory and graphics controller integrated into processor for<br />

extraordinary memory and graphic performance<br />

Maximum performance (e.g. Intel Q67 chipset, DDR3 1333<br />

memory with support of dual channel technology)<br />

High data transfer rates (e.g. with serial ATA Solid-State Drive<br />

(SLC) with 50 GB, serial ATA hard disks up to 1 TB, Dual<br />

Gigabit Ethernet, <strong>PC</strong>I-Express 2.0 technology)<br />

Reduction in downtimes through high system availability<br />

Secure 24-hour operation (high MTBF, variable-speed fan)<br />

Efficient self-diagnostics (front status LEDs for fan and<br />

temperature, SIMATIC I<strong>PC</strong> DiagMonitor)<br />

High degree of data security due to RAID1 (mirror disks<br />

system) or RAID5 (striping with parity)<br />

"Hot swap" removable frame in RAID configuration<br />

(replacement of hard disk during operation)<br />

Fast identification and replacement of the hard disk in the<br />

event of a fault thanks to RAID alarm LEDs<br />

Solid-State Drive (SSD) in Single Level Cell (SLC) architecture<br />

Redundant power supply with "hot swap" functionality<br />

(replacement of power supply module during operation)<br />

High flexibility and user friendliness during commissioning,<br />

operation and service<br />

Preinstalled and activated operating system<br />

iAMT (Intel Active Management Technology) functionality for<br />

remote access to the I<strong>PC</strong> (remote maintenance)<br />

Fast restoration of the delivery status of the HDD thanks to<br />

restore DVD<br />

Low noise output thanks to controlled fans<br />

Universal implementation as an industrial workstation or<br />

server<br />

RAID1/RAID5 onboard (a <strong>PC</strong>I slot is not occupied by the RAID<br />

Controller)<br />

Flexible applications in many different positions with<br />

telescopic rails or as tower industrial <strong>PC</strong><br />

High degree of flexibility and expandability thanks to<br />

integrated interfaces and 7 slots (<strong>PC</strong>I and <strong>PC</strong>I-Express)


■ Benefits (continued)<br />

High industrial compatibility and compactness for 24-hour<br />

use in an industrial environment<br />

Maximum processor performance (in maximum configuration)<br />

without loss of power (throttling) at ambient temperatures of up<br />

to 40 °C<br />

Distinct product design with fully-coated, dirt-resistant<br />

surfaces<br />

Metal enclosure with a high degree of electromagnetic<br />

compatibility for use in industrial areas and in domestic,<br />

business and commercial environments<br />

Suitable for installing in space-saving control cabinets only<br />

500 mm deep<br />

Dust protection thanks to overpressure ventilation concept<br />

with fan on the front and dust filter<br />

Special hard disk holders and card retainers for protection<br />

against vibration and shock<br />

Cost reductions through high investment security<br />

Availability of at least 1.5 years, guaranteed availability of<br />

spare parts for 3 years<br />

System-tested with SIMATIC components<br />

Certification for worldwide marketing (cULus)<br />

Support for legacy interfaces (PS/2, COM, LPT)<br />

Installation compatible for many device generations<br />

Worldwide service and support<br />

■ Application<br />

The SIMATIC I<strong>PC</strong>547D offers system integrators, cabinet<br />

designers, plant constructors and mechanical equipment<br />

manufacturers a 19" rack <strong>PC</strong> platform for high-performance<br />

applications and IT applications at the control and cell levels. It<br />

can be used for:<br />

process and visualization applications<br />

industrial high-end image processing<br />

quality assurance/monitoring tasks<br />

measuring and control tasks<br />

data acquisition/management<br />

The SIMATIC <strong>PC</strong>547D has the CE mark for use in the industrial<br />

sector as well as in residential and commercial areas, and small<br />

businesses. In addition to industrial applications, it can therefore<br />

also be used in building services automation or in facilities open<br />

to the public.<br />

The SIMATIC Rack I<strong>PC</strong>s can be ordered in connection with<br />

WinCC flexible or WinCC as SIMATIC HMI packages at favorable<br />

prices.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Design<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>547D<br />

Basic design<br />

All-metal 19" enclosure for flush mounting (4 HU) for high<br />

electromagnetic compatibility and mechanical ruggedness;<br />

lacquered on the outside<br />

Prepared for mounting on telescopic rails<br />

Horizontal and vertical installation is possible. It can be used<br />

as an industrial tower <strong>PC</strong> with the appropriate kit<br />

Lockable front flap for authorized access to front swap media,<br />

operator controls (Reset, Power), USB interfaces, front fan and<br />

dust filter<br />

Card retainer for <strong>PC</strong> modules for safe transport (vibration and<br />

shock)<br />

Replacement of <strong>PC</strong> components (e.g. <strong>PC</strong> cards or HDD) with<br />

a single tool<br />

Replacement of the dust filter without tool<br />

Dust protection by means of overpressure ventilation using<br />

bearing seated front fan through filter<br />

6 slots for installing drives<br />

- Front: 1 x 3.5"; 3 x 5.25" or 1 x 3.5"; 1 x 5.25"; 3 x HDD swap<br />

frames (low profile)<br />

- Internal: 2 x 3.5"<br />

Graphics onboard, Intel HD 2000 integrated in the processor,<br />

up to 2560 x 1600 pixels, 60 Hz, 32-bit colors<br />

Interfaces:<br />

- 2 x Intel LAN 10/100/1000 Mbit/s (RJ45, teaming-capable)<br />

- 11 x USB 2.0: 8 x rear, 2 x front, 1 x internal e.g. for software<br />

dongle with optional interlocking<br />

- 1 x DisplayPort, 1 x DVI-I , 1 x COM1, 2 x PS/2<br />

- Audio: Line In/Out, Mic<br />

7 spare slots for expansions (all long):<br />

-4x <strong>PC</strong>I<br />

- 1 x <strong>PC</strong>I-Express x16<br />

- 1 x <strong>PC</strong>I-Express x16 (4 lanes)<br />

- 1 x <strong>PC</strong>I-Express x8 (1 lane)<br />

Power supply:<br />

- AC (100 ... 240 V, 50 ... 60 Hz)<br />

5/11<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>547D<br />

■ Design (continued)<br />

Design versions<br />

Processors:<br />

- Intel Core i7- 2600 (4C/8T, 3.40 GHz, 8 MB Last Level Cache,<br />

Turbo Boost 2.0, EM64T, VT-x/-d, iAMT 7.0)<br />

- Intel Core i5-2400 (4C/4T, 3.10 GHz, 6 MB Last Level Cache,<br />

Turbo Boost 2.0, EM64T, VT-x/-d, iAMT 7.0)<br />

- Intel Pentium Dual Core G850 (2C/2T, 2.90 GHz, 3 MB Last<br />

Level Cache, EM64T, VT)<br />

Main memory expansion of 1 GB up to 32 GB,<br />

DDR3 1333 SDRAM (configured as dual channel for the<br />

highest performance from 2 GB upwards)<br />

- Available memory configurations: 1 GB, 2 GB, 4 GB,<br />

8GB 2) , 16 GB 2)<br />

Graphic expansion:<br />

- <strong>PC</strong>I-Express graphic card x16 (Dual Head: 2 x VGA or<br />

2 x DVI-D), 512 MB, up to 2048 x 1536 pixels, 85 Hz, 32-bit<br />

colors<br />

- Adapter cable (DVI-I to VGA) for the onboard graphic<br />

interface (1 x VGA) for connecting an analog monitor<br />

Drives:<br />

- Serial ATA 3.5" hard disks with NCQ technology<br />

- Solid-State Drive (SSD) Serial ATA 2.5" with SLC technology<br />

- Internal installation:<br />

1 x 500 GB<br />

1 x 1 TB<br />

RAID1, 1 TB (2 x 1 TB, mirror disks), RAID controller onboard<br />

1 x 50 GB SSD (SLC)<br />

- Installed on front in low-profile swap frame (hot swapping in<br />

RAID configuration):<br />

1 x 500 GB<br />

2 x 500 GB<br />

RAID1, 1 TB (2 x 1 TB, mirror disks), RAID controller onboard<br />

RAID 5, 2 TB (3 x 1 TB, striping with parity), RAID controller<br />

onboard<br />

- 1 x 50 GB SSD (SLC)<br />

- RAID1, 1 TB (2 x 1 TB, mirror disks), RAID controller onboard<br />

- 1 x 50 GB SSD (SLC) (operating system, if configured,<br />

installed on SSD)<br />

- Optical drives: DVD-ROM or DVD±R/RW<br />

Interfaces:<br />

- 1 x COM2 and 1 x LPT on rear<br />

Power supply:<br />

- 100 ... 240 V AC, 50 ... 60 Hz redundant<br />

Country-specific power cable<br />

Preinstalled and activated operating systems<br />

- Windows XP Professional multi language (32-bit)<br />

- Windows 7 Ultimate multi language (32/64-bit)<br />

- Windows Server 2008 Standard Edition 3)<br />

incl. 5 Clients multi language (32-bit)<br />

- Windows Server 2008 R2 Standard Edition 3)<br />

incl. 5 Clients multi language (64-bit)<br />

1) Further information can be found under "Expansion components".<br />

2) Can only be used on 64-bit operating systems<br />

3) Available soon<br />

5/12<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Front view of SIMATIC Rack I<strong>PC</strong>547D, with front door open<br />

Rear view of SIMATIC I<strong>PC</strong>547D<br />

A Tower Kit can be ordered as an accessory for converting the<br />

computer into an industrial tower <strong>PC</strong>.<br />

See "Ordering data for accessories"


■ Function<br />

Multi Core processor technology<br />

Thanks to the use of two or four processor cores, the Multi Core<br />

processors are ideally suited to multi-thread application<br />

programs and multitasking. Several demanding applications –<br />

such as visualization applications with demanding graphics or<br />

programs executing extensive calculations – can be executed at<br />

the same time to enhance the response time of the system.<br />

Thanks to energy-optimized Multi Core technology and<br />

outstanding energy-saving properties, the Core processors<br />

permit the execution of highly complex applications even at<br />

increased temperatures up to 40 °C without loss of performance.<br />

The SIMATIC I<strong>PC</strong>547D is preconfigured for Multi Core<br />

technology with Intel Core processors and Microsoft operating<br />

systems, and offers higher performance and better multitasking<br />

in the industrial environment.<br />

Multi-display technology<br />

The multi-display architecture with its modern functions for<br />

desktop and application management supports working with<br />

several screens and therefore considerably enhances productivity.<br />

The SIMATIC I<strong>PC</strong>547D with an optional dual-head graphic<br />

card (<strong>PC</strong>I Express x16) is optimized for industrial multi-display<br />

environments. The following screen modes are supported:<br />

Native DualView, Span or Big Desktop, Clone.<br />

Connection options: 2 x VGA or 2 x DVI-D<br />

In addition, in the SIMATIC I<strong>PC</strong>547D you can use the two already<br />

existing onboard graphic interfaces in combination with the<br />

optional dual-head graphic card is used so that operation with<br />

up to four monitors is possible.<br />

Monitoring functions<br />

Integrated monitoring functions: Temperature inside enclosure,<br />

fan speed (CPU, power supply and front fan), program<br />

execution (watchdog), battery.<br />

Expanded diagnostics/messages via Ethernet, e-mail, text<br />

message and for direct transfer to SIMATIC software via O<strong>PC</strong><br />

(optionally via SIMATIC I<strong>PC</strong> DiagMonitor):<br />

Operating hours counter<br />

Hard disk status, also for RAID configurations<br />

System mode<br />

Automatic logging of all alarms by means of a log file<br />

Capability for central monitoring of networked SIMATIC I<strong>PC</strong><br />

IAMT functionality (Intel Active Management Technology)<br />

This feature allows remote access to the I<strong>PC</strong> (for service work)<br />

even if the operating system is shut down for diagnostics and<br />

troubleshooting:<br />

Controlled startup/shutdown of the I<strong>PC</strong><br />

Access to BIOS settings and possible BIOS update<br />

Measures by means of remote access in the event of a fault,<br />

e.g. reboot<br />

Software updates from integrated ISO image<br />

RAID controller onboard<br />

RAID1 (mirroring) for automatic data mirroring on two SATA hard<br />

disks, or RAID5 (striping with parity) for optimized utilization of<br />

capacity with high degree of fault tolerance on three SATA hard<br />

disks.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Integration<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>547D<br />

Integrated interfaces:<br />

Ethernet<br />

The integrated Ethernet interfaces (10/100/1000 Mbit/s;<br />

teaming-capable) can be used for IT communication and for<br />

exchanging data with PLCs such as SIMATIC S7 (using the<br />

"SOFTNET S7" software package).<br />

Other interfaces<br />

As for connecting other I/O devices, 5 free slots are available<br />

for <strong>PC</strong> modules and 2 free <strong>PC</strong>I Express x16 slots for optional<br />

graphic expansions as well as 11 USB 2.0 and serial/parallel<br />

interfaces.<br />

5/13<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>547D<br />

■ Technical specifications<br />

SIMATIC I<strong>PC</strong>547D<br />

General features<br />

Design 19" rack, 4 HU, externally painted<br />

Processor Intel Core i7-2600<br />

(4C/8T, 3.40 GHz, 8 MB Last Level<br />

Cache, Turbo Boost 2.0, EM64T,<br />

VT-x/-d, iAMT)<br />

Intel Core i5-2400<br />

(4C/4T, 3.10 GHz, 6 MB Last Level<br />

Cache, Turbo Boost 2.0, EM64T,<br />

VT-x/-d, iAMT)<br />

Intel Pentium Dual Core G850<br />

(2C/2T, 2.90 GHz, 3 MB Last Level<br />

Cache, EM64T, VT)<br />

Chipset Intel Q67<br />

Main memory From 1 GB DDR3 1333 SDRAM<br />

Dual channel support<br />

4 DIMM base<br />

Expandable up to 32 GB 1)<br />

Spare slots for expansions (all 4x <strong>PC</strong>I<br />

long)<br />

1 x <strong>PC</strong>I-Express x16<br />

1 x <strong>PC</strong>I-Express x16 (4 lanes)<br />

1 x <strong>PC</strong>I-Express x8 (1 lane)<br />

Graphics Onboard Intel HD 2000 graphics<br />

controller integrated in processor;<br />

Shared Video Memory up to<br />

1.7 GB; up to 2560 x 1600 pixels at<br />

60 Hz image refresh rate and<br />

32-bit colors<br />

<strong>PC</strong>I Express graphic card (Dual<br />

Head: 2 x VGA or 2 x DVI-D) in the<br />

<strong>PC</strong>Ie x16 slot; 512 MB; up to<br />

2048 x 1536 pixels at 85 Hz image<br />

refresh rate and 32 bit colors<br />

(optional)<br />

Operating system Without<br />

Preinstalled and activated<br />

(supplied on restore DVD)<br />

Windows XP Professional MUI<br />

(32-bit)<br />

Windows 7 Ultimate MUI 4)<br />

(32/64-bit)<br />

Windows Server 2008 incl.<br />

5 Client MUI (32-bit)<br />

Windows Server 2008 R2 4) incl.<br />

5 Client MUI (64-bit)<br />

MUI: Multilanguage User Interface,<br />

5 languages, English, French,<br />

German, Italian, Spanish; projectspecific<br />

on request<br />

Linux 3)<br />

Other<br />

Power supply 100 ... 240 V AC, 50 ... 60 Hz,<br />

with bridging of short-term power<br />

failures: max. 20 ms at<br />

0.85% rated voltage<br />

Redundant 100 ... 240 V AC,<br />

50 ... 60 Hz<br />

5/14<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Drives<br />

Hard disk, SATA 3.5" with NCQ Installation in internal drive support<br />

technology<br />

500GB<br />

Solid State Drive, SATA 2.5" with 1TB<br />

SLC technology<br />

RAID1 2) 1 TB<br />

(2 x 1 TB, mirror disks)<br />

50 GB Solid State Drive<br />

Mounted in front drive support in<br />

swap frame (low profile)<br />

500GB<br />

2x 500GB<br />

RAID1 2) 1 TB<br />

(2 x 1 TB, mirror disks), "Hot-Swap"<br />

RAID5 2) 2 TB (3 x 1 TB, striping<br />

with parity), "Hot-Swap"<br />

50 GB Solid State Drive<br />

RAID1 2) SIMATIC I<strong>PC</strong>547D<br />

1 TB (2 x 1 TB, mirror<br />

disks), "Hot-Swap" + 50 GB Solid-<br />

State Drive (operating system<br />

installed on SSD if configured<br />

accordingly)<br />

DVD-ROM, 5.25", SATA 16 x (DVD media)<br />

32 x (CD media)<br />

DVD±R/RW, 5.25", SATA 16x 24x 8x(DVD media)<br />

48 x 48 x 32 x (CD media)<br />

Slots for drives Front:<br />

3x 5.25"<br />

1x 3.5"<br />

Internal:<br />

2x 3.5"<br />

Interfaces<br />

Ethernet 2 x Intel 10/100/1000 Mbit/s<br />

(RJ45, teaming-capable)<br />

USB 2.0 2 x front (high current)<br />

8 x rear (high current)<br />

1 x internal (high current),<br />

e. g. for USB dongle with optional<br />

interlocking<br />

Serial 9-pole COM1 (V.24); COM2 (V.24)<br />

(optional)<br />

Parallel LPT (optional)<br />

VGA Optional via adapter<br />

DVI-I 1 x<br />

DisplayPort 1 x<br />

Keyboard PS/2<br />

Mouse PS/2<br />

Audio 1 x Line In; 1 x Line Out; 1 x Micro


■ Technical specifications (continued)<br />

Monitoring functions<br />

Basic functionality Message locally via DiagBase<br />

software<br />

Temperature Violation of permissible operating<br />

temperature range<br />

Fan Speed monitoring<br />

1 x front fan<br />

1 x CPU fan<br />

1 x power supply fan<br />

Watchdog Monitoring of program execution<br />

Monitoring time can be parameterized<br />

in software<br />

Monitoring functions via the SIMATIC I<strong>PC</strong> DiagMonitor Version<br />

network<br />

V4.3.x.x or higher (optional)<br />

Remote monitoring capability for:<br />

Watchdog<br />

Temperature<br />

Fan speed<br />

Battery monitoring<br />

Hard disk monitoring (SMART)<br />

System/Ethernet monitoring<br />

Communication:<br />

Ethernet interface (SNMP<br />

protocol)<br />

O<strong>PC</strong> for integration in SIMATIC<br />

software<br />

Client server architecture<br />

Structure of log files<br />

Front LEDs POWER (<strong>PC</strong> switched on)<br />

HARDDISK (access to hard disk)<br />

TEMP (temperature monitoring)<br />

FAN (fan monitoring)<br />

Additional RAID alarm LEDs behind<br />

the front flap<br />

Ambient conditions<br />

Degree of protection IP30 front, IP20 rear according to<br />

EN 60529<br />

Dust protection With the front door closed<br />

according to IEC 60529 filter class<br />

G2 EN 779, 99% of particles<br />

> 0.5 mm are filtered<br />

Protection class Protection class I according to<br />

IEC 61140<br />

Vibration load during operation IEC 60068-2-6, 10 cycles<br />

20 ... 58 Hz: 0.015 mm<br />

58 ... 200 Hz: 2 m/s2 (approx. 0.2 g)<br />

Note:<br />

Restrictions in use of optical drives<br />

and HDD in swap frames<br />

Shock load during operation IEC 60068-2-27<br />

Half-sine: 9.8 m/s 2 SIMATIC I<strong>PC</strong>547D<br />

, 20 ms<br />

(approx. 1 g), 100 shocks per axis<br />

Note:<br />

Restrictions in use of optical drives<br />

and HDD in swap frames<br />

1) Memory information:<br />

In order to use a memory expansion with more than 4 GB, a 64-bit<br />

operating system is required. In the case of configurations with 4 GB,<br />

the visible memory can be reduced to about 3.5 GB or less (with<br />

32-bit operating systems). In configurations with 8 GB, the visible<br />

memory can be reduced to about 7.5 GB or less.<br />

2) SATA RAID controller onboard in Intel Q67 chipset<br />

3) Suitable for specific LINUX versions in accordance with the specifications<br />

of the <strong>Siemens</strong> manufacturer's declaration "Suited for LINUX",<br />

see www.siemens.com/simatic-pc/suited-for-linux<br />

(LINUX is a trademark of Linus Torvald).<br />

4) Available soon<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>547D<br />

Electromagnetic compatibility<br />

(EMC)<br />

Emitted interference EN 61000-6-3; EN 61000-6-4;<br />

CISPR 22 / EN 55022 Class B;<br />

FCC Class A; EN 61000-3-2<br />

Class D; EN 61000-3-3<br />

Immunity to conducted interference<br />

on the supply lines<br />

Immunity to interference on signal<br />

lines<br />

± 2 kV (IEC 61000-4-4, burst)<br />

± 1 kV (IEC 61000-4-5, symm.<br />

surge)<br />

± 2 kV (IEC 61000-4-5, asymm.<br />

surge)<br />

±2 kV (IEC 61000-4-4, burst,<br />

length > 30 m)<br />

± 1 kV (IEC 61000-4-4, burst,<br />

length < 30 m)<br />

± 2 kV (IEC 61000-4-5, surge,<br />

length > 30 m)<br />

Immunity to static discharge ± 4 kV, contact discharge<br />

(IEC 61000-4-2)<br />

±8 kV, air discharge<br />

(IEC 61000-4-2)<br />

Immunity to high radio frequency<br />

interference<br />

1 V/m <strong>80</strong>% AM; 2 ... 2.7 GHz<br />

(IEC 61000-4-3)<br />

10 V/m <strong>80</strong>% AM; <strong>80</strong> MHz ... 1 GHz<br />

and 1.4 GHz … 2 GHz<br />

(IEC 61000-4-3);<br />

10 V, 10 kHz ... <strong>80</strong> MHz<br />

(IEC 61000-4-6)<br />

Immunity to magnetic fields 100 A/m, 50/60 Hz (IEC 61000-4-8)<br />

Ambient temperature during<br />

operation<br />

SIMATIC I<strong>PC</strong>547D<br />

5 ... 40 °C<br />

Note:<br />

Limitations for operation of<br />

DVD±R/RW<br />

Humidity during operation 5 ... <strong>80</strong>% at 25 °C<br />

(no condensation)<br />

Approvals<br />

Safety regulations IEC 60950-1; UL60950; CSA<br />

Approvals cULus 60950<br />

CE mark For use in industrial areas as well as<br />

domestic, business and commercial<br />

environments:<br />

Emitted interference:<br />

EN 61000-6-3:2007<br />

Noise immunity:<br />

EN 61000-6-2:2005<br />

Dimensions and weights<br />

Mounting dimensions (W x H x D) 434 x 177 x 446<br />

in mm<br />

Weight, approx. 19 kg<br />

Note regarding SIMATIC <strong>PC</strong> operating system licenses<br />

The accompanying operating system license is only valid for<br />

installation on the respective supplied SIMATIC I<strong>PC</strong>. Installation<br />

can only be performed on these SIMATIC systems in accordance<br />

with Microsoft OEM licensing regulations.<br />

5/15<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>547D<br />

■ Ordering data Order No. Order No.<br />

Configuration 3)<br />

Configuration 3)<br />

1<br />

SIMATIC I<strong>PC</strong>547D<br />

Interfaces:<br />

2 x Gbit LAN (RJ45),<br />

1 x DisplayPort,<br />

1 x SCI-I, 8 x USB at the rear,<br />

2 x USB at the front, 1 x USB<br />

internal, 1 x serial (COM1),<br />

2 x PS/2, audio, 7 slots (all long):<br />

4 x <strong>PC</strong>I, 1 x <strong>PC</strong>Ie x16,<br />

1 x <strong>PC</strong>Ie x16 (4 lanes),<br />

1 x <strong>PC</strong>Ie x8 (1 lane);<br />

slots: 6 (3 x 5.25",<br />

1 x 3.5" externally accessible;<br />

2 x 3.5" internally accessible);<br />

temperature and fan monitoring,<br />

watchdog, card retainer<br />

Processors<br />

D 6AG4 104 - 12 7 777 - 7 7 7 7<br />

Pentium Dual Core G850 (2C/2T,<br />

2.90 GHz, 3 MB Last Level<br />

Cache, EM64T, VT)<br />

A<br />

Core i5-2400 (4C/4T, 3.10 GHz,<br />

6 MB Last Level Cache, Turbo<br />

Boost 2.0, EM64T, VT-x/-d, iAMT)<br />

C<br />

Core i7-2600 (4C/8T, 3.40 GHz,<br />

8 MB Last Level Cache, Turbo<br />

Boost 2.0, EM64T, VT-x/-d, iAMT)<br />

Drives:<br />

D<br />

500 GB HDD SATA; internal A<br />

1 TB HDD SATA; internal B<br />

RAID1, 1 TB (2 x 1 TB HDD<br />

SATA, mirror disks); internal 1)<br />

D<br />

Solid-State Drive SATA 50 GB<br />

(SLC); internal<br />

E<br />

500 GB HDD SATA in swap<br />

frame; front<br />

G<br />

2 x 500 GB HDD SATA in swap<br />

frame; front<br />

H<br />

RAID1, 1 TB (2 x 1 TB HDD<br />

SATA, mirror disks) in swap<br />

frame; for hot swapping; at the<br />

front<br />

P<br />

RAID5, 2 TB (3 x 1 TB HDD<br />

SATA, striping with parity) in<br />

swap frame; for hot swapping;<br />

at the front<br />

R<br />

Solid-State Drive SATA 50 GB<br />

(SLC) in swap frame; at the front<br />

S<br />

RAID1, 1 TB (2 x 1 TB HDD<br />

SATA, mirror disks) in swap<br />

frame; hot swapping; at the front<br />

+ Solid-State Drive SATA 50 GB<br />

(SLC) in swap frame; at the front<br />

(operating system if available on<br />

SSD)<br />

Memory expansion:<br />

T<br />

1 GB DDR3 SDRAM (1 x 1 GB),<br />

single channel<br />

0<br />

2 GB DDR3 SDRAM (2 x 1 GB),<br />

dual channel<br />

1<br />

4 GB DDR3 SDRAM (2 x 2 GB),<br />

dual channel<br />

2<br />

8 GB DDR3 SDRAM 2)<br />

3<br />

(2 x 4 GB), dual channel<br />

16 GB DDR3 SDRAM 2)<br />

4<br />

(4 x 4 GB), dual channel<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

1) Not in combination with redundant power supply<br />

2) Can only be used on 64-bit operating systems<br />

3) For an up-to-date overview, see the SIMATIC <strong>PC</strong> online configurator<br />

at: www.siemens.com/ipc-configurator<br />

4) Available soon<br />

5/16<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>547D<br />

(continued)<br />

Swap media:<br />

D 6AG4 104 - 2 7 7 7 7 - 7 777<br />

DVD-ROM 1<br />

DVD±RW Drive<br />

Expansions (hardware)<br />

2<br />

Without expansions (HW);<br />

onboard graphics<br />

0<br />

No expansions (HW); onboard<br />

graphics; DVI-I VGA-compliant<br />

adapter cable for onboard<br />

graphics<br />

1<br />

Serial (COM2) & parallel (LPT);<br />

onboard graphics<br />

2<br />

Serial (COM2) and parallel<br />

(LPT); onboard graphics; DVI-I<br />

VGA-compliant adapter cable<br />

for onboard graphics<br />

3<br />

Serial (COM2) & parallel (LPT) +<br />

<strong>PC</strong>Ie x16 graphic card (Dual<br />

Head: 2 x VGA or 2 x DVI-D),<br />

512 MB<br />

Operating systems<br />

(preinstalled and activated)<br />

4<br />

Windows XP Professional, MUI<br />

(Eng, Ger, Fr, It, Sp), 32 bit, SP3<br />

B<br />

Windows 7 Ultimate, MUI<br />

(Eng, Ger, Fr, It, Sp), 32 bit,<br />

SP1 supplied<br />

E<br />

Windows 7 Ultimate, MUI<br />

(Eng, Ger, Fr, It, Sp), 64 bit,<br />

SP1 supplied<br />

F<br />

Windows Server 2008 Standard<br />

Edition incl. 5 clients, MUI 4)<br />

(Eng, Ger, Fr, It, Sp), 32 bit, SP1,<br />

P<br />

SP2 supplied<br />

Windows Server 2008 R2 4)<br />

Q<br />

Standard Edition incl. 5 Clients,<br />

MUI (Eng, Fr, Ger, It, Sp), 64-bit,<br />

SP1 supplied<br />

Without operating system X<br />

Expansions (software)<br />

SIMATIC I<strong>PC</strong> DiagMonitor V4.3<br />

A<br />

Software enclosed<br />

SIMATIC I<strong>PC</strong> Image & Partition<br />

B<br />

Creator V3.2 software included<br />

SIMATIC I<strong>PC</strong> DiagMonitor V4.3<br />

C<br />

+ Image & Partition Creator V3.2<br />

software included<br />

Without expansions (software) X<br />

Power supply, with countryspecific<br />

cable:<br />

100/240V AC industrial power<br />

supply; power cable for Europe<br />

100/240 V AC industrial power<br />

supply; USA power cable<br />

100/240V AC industrial power<br />

supply; power cable for China<br />

2 x 100/240 V AC redundant<br />

industrial power supply; without<br />

power cable<br />

0<br />

4<br />

5<br />

6


<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

■ Ordering data Order No. Order No.<br />

Preferred versions (ex-stock)<br />

SIMATIC I<strong>PC</strong>547D<br />

Pentium Dual Core G850 (2C/2T,<br />

2.90 GHz, 3 MB Last Level<br />

Cache, EM64T, VT); 500 GB HDD<br />

SATA internal; 1 GB DDR3<br />

SDRAM (1 x 1 GB), single<br />

channel; DVD-ROM; interfaces:<br />

2 x Gbit LAN (RJ45), 1 x serial,<br />

8 x USB rear, 2 x USB front,<br />

1 x USB internal, 2 x PS/2, audio;<br />

100/240 V industrial power<br />

supply, power cable for Europe;<br />

without operating system<br />

Core i5-2400 (4C/4T, 3.10 GHz,<br />

6 MB Last Level Cache, Turbo<br />

Boost 2.0, EM64T, VT-x/-d, iAMT);<br />

RAID1, 1 TB (2 x 1 TB HDD SATA,<br />

mirror disks) in swap frame,<br />

for hot swapping, at the front;<br />

4 GB DDR3 SDRAM (2 x 2 GB)<br />

dual channel; DVD±RW;<br />

interfaces: 2 x Gbit LAN (RJ45),<br />

2 x serial, 1 x parallel, 8 x USB<br />

rear, 2 x USB front, 1 x USB<br />

internal, 2 x PS/2, Audio;<br />

100/240V industrial power supply,<br />

power cable for Europe; without<br />

operating system<br />

Core i7-2600 (4C/8T, 3.40 GHz,<br />

8 MB Last Level Cache, Turbo<br />

Boost 2.0, EM64T, VT-x/-d, iAMT);<br />

RAID1, 1 TB (2 x 1 TB HDD SATA,<br />

mirror disks) in swap frame, for<br />

hot swapping, at the front; 8 GB<br />

DDR3 SDRAM (2 x 4 GB), dual<br />

channel; DVD±RW; interfaces:<br />

2 x Gbit LAN (RJ45), 2 x serial,<br />

1 x parallel, 8 x USB rear, 2 x USB<br />

front, 1 x USB internal, 2 x PS/2,<br />

audio; 100/240 V industrial power<br />

supply, power cable for Europe,<br />

Windows 7 Ultimate MUI<br />

(Eng, Ger, Fr, It, Sp), 64-bit, SP1<br />

supplied<br />

6AG4 104-2AA01-0XX0<br />

6AG4 104-2CP22-2XX0<br />

6AG4 104-2DP32-2FX0<br />

Note:<br />

Software Packages with SIMATIC WinCC flexible, SIMATIC WinCC and<br />

SIMATIC WinAC RTX (F) can be ordered together with the SIMATIC I<strong>PC</strong><br />

with a price advantage.<br />

More information under "Embedded Bundles / Packages for<br />

industrial <strong>PC</strong>s".<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Accessories<br />

Memory expansion<br />

1 GB DDR3 1333 SDRAM,<br />

DIMM (1 x 1 GB)<br />

2 GB DDR3 1333 SDRAM,<br />

DIMM, kit for dual-channel<br />

technology (2 x 1 GB)<br />

4 GB DDR3 1333 SDRAM,<br />

DIMM, kit for dual-channel<br />

technology (2 x 2 GB)<br />

8 GB DDR3 1333 SDRAM,<br />

DIMM, kit for dual-channel<br />

technology (2 x 4 GB)<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>547D<br />

6ES7 648-2AJ40-0LA0<br />

6ES7 648-2AJ50-0LB0<br />

6ES7 648-2AJ60-0LB0<br />

6ES7 648-2AJ70-0LB0<br />

Tower Kit 6ES7 648-1AA00-0XC0<br />

for converting the computer into<br />

an industrial tower <strong>PC</strong><br />

Retainer 6ES7 648-1AA00-0XK0<br />

for pin assignment of the internal<br />

USB port<br />

Power cable, straight, 3 m long<br />

Austria, Belgium, Finland, 6ES7 900-0AA00-0XA0<br />

France, Germany, Netherlands,<br />

Spain, Sweden<br />

United Kingdom 6ES7 900-0BA00-0XA0<br />

Switzerland 6ES7 900-0CA00-0XA0<br />

USA 6ES7 900-0DA00-0XA0<br />

Italy 6ES7 900-0EA00-0XA0<br />

China 6ES7 900-0FA00-0XA0<br />

Rack unit for low-profile HDD<br />

swap frame<br />

for 3.5" hard disk, SATA<br />

(without hard disk)<br />

Expansion components<br />

SIMATIC <strong>PC</strong> keyboard<br />

German/international<br />

6ES7 648-0EG00-1BA0<br />

USB port 6ES7 648-0CB00-0YA0<br />

incl. 4-way USB hub A 6ES7 648-0CD00-0YA0<br />

SIMATIC <strong>PC</strong> USB mouse<br />

(optical, 3-button)<br />

for programming device and <strong>PC</strong><br />

with adapter<br />

A 6ES7 790-0AA01-0XA0<br />

SIMATIC I<strong>PC</strong> USB FlashDrive<br />

8 GB, USB 2.0, metal enclosure,<br />

bootable<br />

A 6ES7 648-0DC50-0AA0<br />

SIMATIC I<strong>PC</strong> Service USB<br />

FlashDrive<br />

8 GB, USB 2.0, metal enclosure,<br />

bootable, with BIOS-Manager,<br />

Image & Partition Creator preinstalled,<br />

incl. CD<br />

B 6AV7 672-8JD01-0AA0<br />

Communication products see expansion components<br />

RMOS real-time operating<br />

system<br />

see expansion components<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

5/17<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>547D<br />

■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical<br />

specifications.<br />

Technical data of the telescopic rails<br />

Carrying capacity per pair, min. 30 kg<br />

Extension length when fully<br />

extended, min.<br />

470 mm<br />

Rail thickness, max. 9.7 mm<br />

Fixing screws M5 x 6 mm<br />

The fixing screws of the telescopic rails should not project more<br />

than 5 mm into the enclosure.<br />

The enclosure is prepared for the following telescopic rails:<br />

Co. Rittal: Type 3659.1<strong>80</strong> for 600 mm cabinet /<br />

Type RP 3659.190 for <strong>80</strong>0 mm cabinet<br />

Co. Schroff: Type <strong>2011</strong>0-072<br />

5/18<br />

14.3<br />

481.4<br />

465.1<br />

433.5<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

445.5<br />

101.6<br />

37.5<br />

18.5<br />

176.5<br />

489<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00452<br />

■ More information<br />

Further information can be found on the Internet at:<br />

www.siemens.com/simatic-pc


■ Overview<br />

The SIMATIC I<strong>PC</strong>547C is a rugged industrial <strong>PC</strong> in 19" rack<br />

design (4 HU).<br />

It offers:<br />

maximum performance<br />

attractive price<br />

Intel Core2 Quad technology<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>547C<br />

Maximum system performance for complex automation and<br />

visualization tasks<br />

State-of-the-art <strong>PC</strong> technology (e. g. Intel Core2 Quad / Duo<br />

and Extended Memory 64 (EM64T) processor technology)<br />

High-level performance (e. g. Intel Q45G Express Chipset,<br />

DDR2 <strong>80</strong>0 memory supporting dual-channel technology)<br />

High data transfer rates (e. g. with Serial ATA hard disks up to<br />

500 GB, Gigabit Ethernet, <strong>PC</strong>I-Express technology)<br />

Minimized downtimes thanks to high system availability<br />

Secure 24-hour operation (high MTBF, variable-speed fan)<br />

Efficient self-diagnosis (front status LED for fan and<br />

temperature, SIMATIC <strong>PC</strong> DiagMonitor)<br />

High degree of data security due to RAID1 (mirror disks<br />

system) or RAID5 (striping with parity)<br />

Fast identification and replacement of the hard disk in the<br />

event of a fault<br />

"Hot swap" removable frame in RAID configuration<br />

(replacement of hard disk during operation)<br />

Redundant power supply<br />

High flexibility and user friendliness during commissioning,<br />

operation and service<br />

Preinstalled and activated operating system<br />

Fast restoration of the delivery status of the HDD thanks to<br />

restore DVD<br />

Low noise output thanks to controlled fan<br />

Universal implementation as an industrial workstation or<br />

server<br />

RAID1/RAID5 onboard (a <strong>PC</strong>I slot is not occupied by the RAID<br />

controller)<br />

Flexible applications in many different positions with<br />

telescopic rails or as tower industrial <strong>PC</strong><br />

High degree of flexibility and expandability thanks to<br />

integrated interfaces and 7 slots (<strong>PC</strong>I and <strong>PC</strong>I Express)<br />

Industrial compatibility and compactness for 24-hour use in<br />

an industrial environment<br />

Maximum processor performance (in maximum configuration)<br />

without loss of power (throttling) at ambient temperatures of<br />

up to 40 °C<br />

Specific product design with a new front panel design and flat,<br />

coated, dirt-repellent surfaces<br />

Metal enclosure with a high degree of electromagnetic<br />

compatibility for use in industrial areas and in domestic,<br />

business and commercial environments<br />

Suitable for installation in space-saving control cabinets only<br />

500 mm deep<br />

Dust protection thanks to overpressure ventilation concept<br />

with fan on the front and dust filter<br />

Special hard disk holders and card retainers for protection<br />

against vibration and shock<br />

Cost reductions through high investment security<br />

Minimum availability 1.5 years, guaranteed availability of<br />

spare parts for 3 years<br />

System-tested with SIMATIC components<br />

Certification for worldwide marketing (cULus)<br />

Support for legacy interfaces (PS/2, COM, LPT)<br />

Installation compatible for many device generations<br />

Worldwide service and support<br />

5/19<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>547C<br />

■ Application<br />

The SIMATIC I<strong>PC</strong> 547C offers system integrators, cabinet<br />

designers, plant constructors and mechanical equipment<br />

manufacturers a 19" rack <strong>PC</strong> platform for high-performance<br />

applications and IT applications at the control and cell levels.<br />

It can be used for:<br />

process and visualization applications<br />

industrial image processing - high-end image processing<br />

quality assurance/monitoring tasks<br />

measuring, open-loop and closed-loop control tasks<br />

data acquisition/management<br />

The SIMATIC I<strong>PC</strong>547C has the CE mark for use in the industrial<br />

sector as well as in residential and commercial areas, and small<br />

businesses. In addition to industrial applications, it can also be<br />

used in building services automation or in facilities open to the<br />

public.<br />

■ Design<br />

Basic design<br />

All-metal 19" enclosure for flush mounting (4 HU) for high<br />

electromagnetic compatibility and mechanical ruggedness;<br />

lacquered on the outside<br />

Prepared for mounting on telescopic rails<br />

Horizontal and vertical installation is possible. It can be used<br />

as an industrial tower <strong>PC</strong> with the appropriate kit<br />

Lockable front flap for authorized access to front swap media,<br />

operator controls (Reset, Power), USB interfaces, front fan and<br />

dust filter<br />

Card retainer for <strong>PC</strong> modules for safe transport (vibration and<br />

shock)<br />

Replacement of <strong>PC</strong> components (e. g. <strong>PC</strong> cards or HDD) with<br />

a single tool<br />

Replacement of dust filter without tools<br />

Dust protection by means of overpressure ventilation using<br />

bearing seated front fan through filter<br />

6 slots for installing drives<br />

- Front: 1 x 3.5"; 3 x 5.25" or 1 x 3.5"; 1 x 5.25"; 3 x HDD swap<br />

frames (low profile)<br />

- Internal: 2 x 3.5"<br />

Graphics onboard on the <strong>PC</strong>I-Express bus, Intel GMA4500<br />

integrated in chip set, up to 2048 x 1536 pixels, 75 Hz, 16-bit<br />

colors<br />

Interfaces:<br />

- 2 x LAN 10/100/1000 Mbit/s (RJ45, teaming-capable)<br />

- 9 x USB 2.0: 6 x rear, 2 x front, 1 x internal for software<br />

dongle, for example<br />

- 2 x PS/2, 1 x COM1, 1 x VGA<br />

- Audio: Line In/Out, Mic<br />

7 spare slots for expansions (all long):<br />

-4x <strong>PC</strong>I<br />

- 1 x <strong>PC</strong>I-Express x16<br />

- 1 x <strong>PC</strong>I-Express x8 (1 lane)<br />

- 1 x <strong>PC</strong>I-Express x1<br />

5/20<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Design versions<br />

Processor:<br />

- Intel Core2 Quad Q9400, 2.66 GHz, 1333 MHz FSB, 6 MB L2<br />

cache with Extended Memory 64 (EM64) and virtualization<br />

technology (VT)<br />

- Intel Core2 Duo E8400, 3.0 GHz, 1333 MHz FSB, 6 MB L2<br />

cache with Extended Memory 64 (EM64) and virtualization<br />

(VT) technology<br />

- Intel Pentium Dual Core E5300, 2.6 GHz, <strong>80</strong>0 MHz FSB,<br />

2 MB L2 cache with Extended Memory 64 (EM64)<br />

technology<br />

Main memory expansion of 1 GB up to 16 GB,<br />

DDR2 <strong>80</strong>0 SDRAM (configured as dual channel for the highest<br />

performance from 2 GB upwards)<br />

- Available memory configurations: 1 GB, 2 GB, 4 GB, 8 GB 2)<br />

Graphic expansion:<br />

- <strong>PC</strong>I-Express graphic card x16, (Dual Head: 2 x VGA or 2 x<br />

DVI-D) 256 MB, to 2048 x 1536 pixels, 75 Hz, 32-bit colors<br />

- ADD card via <strong>PC</strong>I Express x16 slot, (1 x DVI-D) for<br />

connecting a digital monitor<br />

Drives:<br />

- Serial ATA 3.5" hard disks with NCQ technology<br />

- Internal installation:<br />

1 x 250 GB<br />

1 x 500 GB<br />

RAID1, 500 GB (2 x 500 GB, mirror disks), RAID controller<br />

onboard<br />

- Installed on front in low-profile swap frame (hot swapping in<br />

RAID configuration)<br />

1 x 500 GB<br />

2 x 500 GB<br />

RAID1, 500 GB (2 x 500 GB, mirror disks), RAID controller<br />

onboard<br />

RAID5, 1 TB (3 x 500 GB, striping with parity), RAID<br />

controller onboard<br />

- Optical drives: DVD-ROM or DVD±R/RW<br />

- Diskette drive: 1.44 MB, 3.5"<br />

Interfaces:<br />

- 1 x COM2 and 1 x LPT on rear<br />

Country-specific power cable<br />

Power supply:<br />

- 100 ... 240 V AC, 50 ... 60 Hz; redundant power supply<br />

Preinstalled and activated operating systems<br />

- Windows XP Professional multi language<br />

- Windows Vista Ultimate multi language<br />

- Windows 7 Ultimate multi language<br />

- Windows Server 2003 R2 Standard Edition incl. 5 Client multi<br />

language<br />

- Windows Server 2008 Standard Edition incl. 5 Client<br />

multi language<br />

1) Further information can be found under "Expansion components".<br />

2) Can only be used on 64-bit operating systems


■ Design (continued)<br />

Front view of SIMATIC Rack I<strong>PC</strong>547C, with open front door<br />

A Tower Kit can be ordered as an accessory for converting<br />

the computer into an industrial tower <strong>PC</strong>.<br />

See "Ordering data for accessories"<br />

SIMATIC I<strong>PC</strong>547C<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Function<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>547C<br />

Multi Core processor technology<br />

Thanks to the use of two or four processor cores, the Multi Core<br />

processors are ideally suited to multi-thread application<br />

programs and multitasking. Several demanding applications -<br />

such as visualization applications with demanding graphics or<br />

programs executing extensive calculations - can be executed at<br />

the same time to enhance the response time of the system.<br />

Thanks to energy-optimized Multi Core technology and<br />

outstanding energy-saving properties, the Intel Core2 Quad or<br />

Duo processors operate without any loss of performance even<br />

at increased temperatures up to 40 °C in demanding applications.<br />

The SIMATIC I<strong>PC</strong>547C is preconfigured for Multi Core<br />

technology with Intel Core2 Quad and Duo processors and<br />

Microsoft operating systems, and offers higher performance and<br />

better multitasking in the industrial environment.<br />

Multi-display technology<br />

The multi-display architecture with its modern functions for<br />

desktop and application management supports working with<br />

several screens and therefore considerably enhances productivity.<br />

The SIMATIC I<strong>PC</strong>547C with an optional dual-head graphic<br />

card (<strong>PC</strong>I Express x16) is optimized for industrial multi-display<br />

environments.<br />

The following screen modes are supported: Native DualView,<br />

Span or Big Desktop, Clone.<br />

Connection options: 2 x VGA or 2 x DVI-D<br />

Monitoring functions<br />

Integrated monitoring functions: temperature inside enclosure,<br />

fan speed (CPU, power supply and front fan), program<br />

execution (watchdog)<br />

Expanded diagnostics/messages via Ethernet, e-mail, text<br />

message and for direct transfer to SIMATIC software via O<strong>PC</strong><br />

(optionally via SIMATIC I<strong>PC</strong> DiagMonitor):<br />

Runtime meter<br />

Hard disk status, also for RAID configuration<br />

System status<br />

Automatic logging of all alarms by means of a log file<br />

Capability for central monitoring of networked SIMATIC <strong>PC</strong>s<br />

RAID controller onboard<br />

RAID1 (mirroring) for automatic data mirroring on two SATA hard<br />

disks, or RAID5 (striping with parity) for optimized utilization of<br />

capacity with high degree of fault tolerance on three SATA hard<br />

disks.<br />

■ Integration<br />

Integrated interfaces.<br />

Ethernet<br />

The integrated Ethernet interfaces (10/100/1000 Mbit/s;<br />

teaming-capable) can be used for IT communication and for<br />

exchanging data with PLCs such as SIMATIC S7 (using the<br />

"SOFTNET S7" software packages).<br />

Other interfaces<br />

As for connecting other I/O devices, 6 free slots are available<br />

for <strong>PC</strong> modules and 1 free <strong>PC</strong>I Express x16 slot for optional<br />

graphic expansions as well as 9 USB 2.0 and serial/parallel<br />

interfaces.<br />

5/21<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>547C<br />

■ Technical specifications<br />

SIMATIC I<strong>PC</strong>547C<br />

General features<br />

Design 19" rack, 4 HU, externally painted<br />

Processor Intel Core2 Quad Q9400<br />

(2.66 GHz, 1333 MHz FSB,<br />

6 MB L2 cache, Extended Memory<br />

64 (EM64T) and virtualization (VT-x)<br />

technology)<br />

Intel Core2 Duo E8400<br />

(3.0 GHz, 1333 MHz FSB, 6 MB L2<br />

cache, Extended Memory 64<br />

(EM64T) and virtualization (VT-x)<br />

technology)<br />

Intel Pentium Dual Core E5300<br />

(2.6 GHz, <strong>80</strong>0 MHz FSB, 2 MB L2<br />

cache, Extended Memory 64<br />

(EM64T))<br />

Chipset Intel Q45<br />

Main memory From 1 GB DDR2 <strong>80</strong>0 SDRAM<br />

Dual channel support<br />

4 DIMM base<br />

Expandable up to 16 GB 1)<br />

Spare slots for expansions 4x <strong>PC</strong>I<br />

(all long)<br />

1 x <strong>PC</strong>I-Express x16<br />

1 x <strong>PC</strong>I-Express x8 (1 Lane)<br />

1 x <strong>PC</strong>I-Express x1<br />

Graphics Onboard Intel GMA4500 graphics<br />

controller integrated into chipset;<br />

Dynamic Video Memory; up to<br />

2048 x 1536 pixels for 75 Hz<br />

display refresh rate and 16-bit<br />

colors<br />

<strong>PC</strong>I Express graphic card<br />

(Dual Head: 2 x VGA or 2 x DVI-D)<br />

in the <strong>PC</strong>Ie x16 slot; 256 MB; up to<br />

2048 x 1536 pixels at 75 Hz display<br />

refresh rate and 32 bit colors<br />

(optional)<br />

Operating system None<br />

Preinstalled and activated /<br />

supplied on restore DVD<br />

Windows XP Professional MUI<br />

Windows Vista Ultimate MUI<br />

Windows 7 Ultimate MUI<br />

Windows Server 2003 R2 incl.<br />

5 Client MUI<br />

Windows Server 2008 incl. 5 Client<br />

MUI<br />

MUI: Multilanguage User Interface,<br />

5 languages, English, French,<br />

German, Italian, Spanish; projectspecific<br />

on request<br />

Linux 3)<br />

Other<br />

Power supply 100 ... 240 V AC, 50 ... 60 Hz, with<br />

bridging of short-term power<br />

failures: Max. 16 ms at 0.85% rated<br />

voltage<br />

Redundant 100 ... 240 V AC,<br />

50 ... 60 Hz<br />

5/22<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Drives<br />

Hard disk, 3.5" Serial ATA with Installation in internal drive support<br />

NCQ technology<br />

250GB<br />

500GB<br />

500GB RAID12) , 2x 500GB<br />

(mirror disks)<br />

Mounted in front drive support in<br />

swap frame (low profile)<br />

500GB<br />

2x 500GB<br />

500GB RAID12) , 2x 500GB<br />

(mirror disks), "hot swap"<br />

1 TB RAID52) SIMATIC I<strong>PC</strong>547C<br />

, 3x 500GB<br />

(striping with parity), "hot swap"<br />

DVD-ROM, 5.25", SATA 16x (DVD media)<br />

48 x (CD media)<br />

DVD±R/RW, 5.25", SATA 16x 16x 8x(DVD media)<br />

48 x 48 x 32 x (CD media)<br />

Floppy disk 1.44 MB<br />

Slots for drives Front:<br />

3x 5.25"<br />

1x 3.5"<br />

Internal:<br />

2x 3.5"<br />

Interfaces<br />

Ethernet 2 x 10/100/1000 Mbit/s (RJ45,<br />

team-capability)<br />

USB 2.0 2 x front (high current)<br />

6 x rear (high current)<br />

1 x internal (high current)<br />

e. g. for USB dongle<br />

Serial 9-pole COM1 (V.24); COM2 (V.24)<br />

(optional)<br />

Parallel LPT1 (optional)<br />

VGA 1x<br />

Keyboard PS/2<br />

Mouse PS/2<br />

Audio 1 x Line In; 1 x Line Out; 1 x Micro<br />

Monitoring functions<br />

Basic functionality Message locally via DiagBase<br />

software<br />

Temperature Violation of permissible operating<br />

temperature range<br />

Fan Speed monitoring<br />

1 x front fan<br />

1 x CPU fan<br />

1 x power supply fan<br />

Watchdog Monitoring of program execution<br />

Monitoring time can be parameterized<br />

in software


■ Technical specifications (continued)<br />

Monitoring functions via the<br />

network<br />

SIMATIC I<strong>PC</strong>547C<br />

SIMATIC I<strong>PC</strong> DiagMonitor Version<br />

V4.2.0.13 or higher (optional)<br />

Remote monitoring capability for:<br />

Watchdog<br />

Temperature<br />

Fan speed<br />

Hard disk monitoring (SMART)<br />

System/Ethernet monitoring<br />

(Heart Beat)<br />

Communication:<br />

Ethernet interface (SNMP protocol)<br />

O<strong>PC</strong> for integration in SIMATIC<br />

software<br />

Client server architecture<br />

Layout of log files<br />

Front LEDs POWER (<strong>PC</strong> switched on)<br />

HARDDISK (access to hard disk)<br />

TEMP (temperature monitoring)<br />

FAN (fan monitoring)<br />

Ambient conditions<br />

Degree of protection IP30 front, IP20 rear according to<br />

EN 60529<br />

Dust protection With front door closed: Filter class<br />

G2 EN 779, 99% of particles<br />

> 0.5 mm are filtered out according<br />

to EN 60529<br />

Protection class Protection class I according to<br />

IEC 61140<br />

Vibration load during operation IEC 60068-2-6, 10 cycles<br />

20 ... 58 Hz: 0.015 mm<br />

58 ... 200 Hz: 2 m/s2 (approx. 0.2 g)<br />

Note:<br />

Restrictions in use of optical drives<br />

and HDD in swap frames<br />

Shock load during operation IEC 60068-2-27<br />

Half-sine: 9.8 m/s2 , 20 ms<br />

(approx. 1 g), 100 shocks per axis<br />

Note:<br />

Restrictions in use of optical drives<br />

and HDD in swap frames<br />

1) Memory information:<br />

In order to use a memory expansion with more than 4 GB, a 64-bit<br />

operating system is required. In configurations with at least 4 GB, the<br />

visible memory can be reduced to about 3.5 GB or less (with 32-bit<br />

operating systems) and in configurations with 8 GB, the visible<br />

memory can be reduced to about 7.5 GB or less.<br />

2) SATA RAID controller onboard in Intel CH10DO chipset<br />

3) Suitable for specific LINUX versions in accordance with the specifications<br />

of the <strong>Siemens</strong> manufacturer's declaration "Suited for LINUX",<br />

see www.siemens.com/simatic-pc/suited-for-linux<br />

(LINUX is a trademark of Linus Torvald).<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>547C<br />

Electromagnetic<br />

compatibility (EMC)<br />

Emitted interference EN 61000-6-3; EN 61000-6-4;<br />

CISPR22:2004 Class B; FCC<br />

Class A; EN 61000-3-2 Class D;<br />

EN 61000-3-3<br />

Immunity to conducted interference<br />

on the supply lines<br />

Immunity to interference on<br />

signal lines<br />

± 2 kV (IEC 61000-4-4, burst)<br />

± 1 kV (IEC 61000-4-5, symm.<br />

surge)<br />

± 2 kV (IEC 61000-4-5, asymm.<br />

surge)<br />

±2 kV (IEC 61000-4-4, burst,<br />

length > 30 m)<br />

± 1 kV (IEC 61000-4-4, burst,<br />

length < 30 m)<br />

± 2 kV (IEC 61000-4-5, symm.<br />

surge, length > 30 m)<br />

Immunity to static discharge ± 4 kV, contact discharge<br />

(IEC 61000-4-2)<br />

± 8 kV, air discharge<br />

(IEC 61000-4-2)<br />

Immunity to high radio<br />

frequency interference<br />

1 V/m <strong>80</strong>% AM; 2 ... 2.7 GHz<br />

(IEC 61000-4-3)<br />

10 V/m <strong>80</strong>% AM; <strong>80</strong> MHz ... 1 GHz<br />

and 1.4 GHz … 2 GHz<br />

(IEC 61000-4-3);<br />

10 V, 10 kHz ... <strong>80</strong> MHz<br />

(IEC 61000-4-6)<br />

Immunity to magnetic fields 100 A/m, 50/60 Hz (IEC 61000-4-8)<br />

Ambient temperature during<br />

operation<br />

SIMATIC I<strong>PC</strong>547C<br />

5 ... 40 °C<br />

Note:<br />

Limitations for operation of<br />

DVD±R/RW<br />

Humidity during operation 5 ... <strong>80</strong>% at 25 °C (no condensation)<br />

Approvals<br />

Safety regulations IEC 60950-1; UL60950; CSA<br />

Approvals cULus 60950<br />

CE mark For use in industrial areas as well as<br />

domestic, business and commercial<br />

environments:<br />

Emitted interference:<br />

EN 61000-6-3:2007<br />

Noise immunity:<br />

EN 61000-6-2:2005<br />

Dimensions and weights<br />

Mounting dimensions<br />

434x177x446<br />

(W x H x D) in mm<br />

Weight, approx. 19 kg<br />

Note regarding SIMATIC <strong>PC</strong> operating system licenses:<br />

The accompanying operating system license is only valid for<br />

installation on the supplied SIMATIC <strong>PC</strong>. Installation can only be<br />

performed on these SIMATIC systems in accordance with<br />

Microsoft OEM licensing regulations.<br />

5/23<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>547C<br />

■ Ordering data Order No. Order No.<br />

Configuration 3)<br />

Configuration 3)<br />

1<br />

SIMATIC I<strong>PC</strong>547C<br />

Interfaces: 2 X Gbit LAN (RJ45);<br />

1 x serial (COM1);<br />

6 x USB rear, 2x USB front,<br />

1 x USB internal; 2 x PS/2; audio;<br />

7 slots (4x <strong>PC</strong>I long, 1 x <strong>PC</strong>Ie x16,<br />

1 x <strong>PC</strong>Ie x8 (1 lane),<br />

1 x <strong>PC</strong>Ie x1);<br />

slots: 6 (3 x 5.25", 1 x 3.5" externally<br />

accessible; 2 x 3.5" internally<br />

accessible)<br />

temperature and fan monitoring,<br />

watchdog; card retainer<br />

Processor/motherboard<br />

D 6AG4 104 - 11 7 777 - 7 7 7 7<br />

Pentium Dual Core E5300<br />

(2.6 GHz, <strong>80</strong>0 MHz FSB, 2 MB<br />

L2 cache, EM64-T)<br />

A<br />

Core2 Duo E8400 (3.0 GHz,<br />

1333 MHz FSB, 6 MB L2 cache,<br />

EM64-T, VT)<br />

C<br />

Core2 Quad Q9400 (2.66 GHz,<br />

1333 MHz FSB, 6 MB L2 cache,<br />

EM64-T, VT)<br />

Hard disks:<br />

D<br />

250 GB HDD SATA; internal A<br />

500 GB HDD SATA; internal B<br />

RAID1, 500 GB (2 x 500 GB<br />

HDD SATA, mirror disks);<br />

internal 1)<br />

D<br />

500 GB HDD SATA in swap<br />

frame; at the front<br />

G<br />

2 x 500 GB HDD SATA in swap<br />

frame; at the front<br />

H<br />

RAID1, 500 GB (2 x 500 GB<br />

HDD SATA, mirror disks) in swap<br />

frames; for hot swapping; at the<br />

front<br />

P<br />

RAID5, 1 TB (3 x 500 GB HDD<br />

SATA, striping with parity) in<br />

swap frame; hot swapping;<br />

at the front<br />

Memory expansion:<br />

R<br />

1 GB DDR2 SDRAM (1 x 1 GB),<br />

single channel<br />

0<br />

2 GB DDR2 SDRAM (2 x 1 GB),<br />

dual channel<br />

1<br />

4 GB DDR2 SDRAM (2 x 2 GB),<br />

dual channel<br />

2<br />

8 GB DDR2 SDRAM 2)<br />

(4 x 2 GB), dual channel<br />

3<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

1) Not in combination with redundant power supply<br />

2) Can only be used on 64-bit operating systems<br />

3) For an up-to-date overview, see the SIMATIC <strong>PC</strong> online configurator<br />

at: www.siemens.com/ipc-configurator<br />

5/24<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>547D<br />

(continued)<br />

Swap media:<br />

D 6AG4 104 - 1 7 7 7 7 - 7 777<br />

DVD-ROM; without FDD 1<br />

DVD±RW; without FDD 2<br />

DVD-ROM & FDD 3<br />

DVD±RW & FDD<br />

Expansion (hardware)<br />

4<br />

Without expansions 0<br />

Serial (COM2) and parallel (LPT) 1<br />

Serial (COM2) and parallel (LPT)<br />

+ DVI extension adapter (DVI-D)<br />

2<br />

Serial (COM2) & parallel (LPT) +<br />

<strong>PC</strong>Ie x16 graphic card (Dual<br />

Head: 2 x VGA or 2 x DVI),<br />

256 MB<br />

Operating system<br />

(preinstalled and activated)<br />

3<br />

Windows XP Professional, MUI<br />

(Eng, Ger, Fr, It, Sp), 32 bit, SP3<br />

B<br />

Windows Vista Ultimate, MUI<br />

(Eng, Ger, Fr, It, Sp), 32 bit, SP1,<br />

SP2 supplied<br />

C<br />

Windows 7 Ultimate, MUI<br />

(Eng, Ger, Fr, It, Sp), 32 bit<br />

E<br />

Windows Server 2003 R2<br />

Standard Edition incl. 5 clients,<br />

MUI (Eng, Ger, Fr, It, Sp), 32 bit,<br />

SP2<br />

N<br />

Windows Server 2008 Standard<br />

Edition incl. 5 clients, MUI<br />

(Eng, Ger, Fr, It, Sp), 32 bit, SP1,<br />

SP2 supplied<br />

P<br />

Without operating system<br />

Expansion (software)<br />

X<br />

SIMATIC I<strong>PC</strong> DiagMonitor V4.2<br />

software included<br />

A<br />

SIMATIC I<strong>PC</strong> Image & Partition<br />

Creator V3.1 software included<br />

B<br />

SIMATIC I<strong>PC</strong> DiagMonitor V4.2<br />

and Image & Partition Creator<br />

V3.1 software included<br />

C<br />

Without software<br />

Power supply, with countryspecific<br />

cable:<br />

X<br />

100/240V AC industrial power<br />

supply; power cable for Europe<br />

0<br />

100/240V AC industrial power<br />

supply; power cable for China<br />

5<br />

2 x 100/240 V AC redundant<br />

industrial power supply; without<br />

power cable<br />

6


<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

■ Ordering data Order No. Order No.<br />

Preferred versions (ex-stock)<br />

Accessories<br />

SIMATIC I<strong>PC</strong>547C<br />

Pentium Dual Core E5300 D<br />

(2.6 GHz, <strong>80</strong>0 MHz FSB, 2 MB<br />

L2 Cache, EM64-T); 250 GB<br />

HDD SATA internal; 1 GB DDR2<br />

SDRAM (1 x 1 GB), single<br />

channel; DVD-ROM & FDD;<br />

interfaces: 2 x Gbit LAN (RJ45),<br />

2 x serial, 1 x parallel, 6 x USB<br />

rear, 2 x USB front, 1 x USB<br />

internal, 2 x PS/2, audio;<br />

100/240 V industrial power<br />

supply, power cable for Europe;<br />

without operating system<br />

6AG4 104-1AA03-1XX0<br />

Core2 Duo E8400 (3.0 GHz,<br />

1333 MHz FSB, 6 MB L2 Cache,<br />

EM64-T, VT); 250 GB HDD SATA<br />

internal; 1 GB DDR2 SDRAM<br />

(1 x 1 GB) single channel<br />

DVD±RW & FDD; interfaces:<br />

2 x Gbit LAN (RJ45), 2 x serial,<br />

1 x parallel, 6 x USB rear,<br />

2 x USB front, 1 x USB internal,<br />

2 x PS/2, audio; 100/240 V<br />

industrial power supply, power<br />

cable for Europe; Windows XP<br />

Professional MUI (Eng, Ger, Fr,<br />

It, Sp), 32-bit, SP3<br />

D 6AG4 104-1CA04-1BX0<br />

Core2 Quad Q9400 (2.66 GHz, D 6AG4 104-1DA14-1BX0<br />

1333 MHz FSB, 6 MB L2 Cache,<br />

EM64-T, VT); 250 GB HDD SATA<br />

internal; 2 GB DDR2 SDRAM<br />

(2 x 1 GB), dual channel;<br />

DVD±RW & FDD, interfaces:<br />

2 x Gbit LAN (RJ45), 2 x serial,<br />

1 x parallel, 6 x USB rear,<br />

2 x USB front, 1 x USB internal,<br />

2 x PS/2, audio; 100/240 V<br />

industrial power supply, power<br />

cable for Europe, Windows XP<br />

Professional MUI (Eng, Ger, Fr,<br />

It, Sp), 32-bit SP3<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

1) Not in combination with redundant power supply<br />

2) Can only be used on 64-bit operating systems<br />

3) For an up-to-date overview, see the SIMATIC <strong>PC</strong> online configurator<br />

at: www.siemens.com/ipc-configurator<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Memory expansion<br />

Note:<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>547C<br />

1 GB DDR2 <strong>80</strong>0 DIMM A 6ES7 648-2AF40-0JA0<br />

2 GB DDR2 <strong>80</strong>0, DIMM, kit for<br />

dual channel technology<br />

A 6ES7 648-2AF50-0JB0<br />

4 GB DDR2 <strong>80</strong>0, DIMM, kit for<br />

dual channel technology<br />

A 6ES7 648-2AF60-0JB0<br />

Tower Kit<br />

for converting the computer into<br />

an industrial tower <strong>PC</strong><br />

6ES7 648-1AA00-0XC0<br />

Retainer<br />

for pin assignment of the internal<br />

USB port<br />

Power cable, straight, 3 m long<br />

6ES7 648-1AA00-0XJ0<br />

Austria, Belgium, Finland,<br />

France, Germany, Netherlands,<br />

Spain, Sweden<br />

6ES7 900-0AA00-0XA0<br />

United Kingdom 6ES7 900-0BA00-0XA0<br />

Switzerland 6ES7 900-0CA00-0XA0<br />

USA 6ES7 900-0DA00-0XA0<br />

Italy 6ES7 900-0EA00-0XA0<br />

China 6ES7 900-0FA00-0XA0<br />

Rack unit for low-profile HDD<br />

swap frame<br />

for 3.5" hard disk, SATA<br />

(without hard disk)<br />

Expansion components<br />

SIMATIC <strong>PC</strong> keyboard<br />

German/international<br />

6ES7 648-0EG00-1BA0<br />

USB port 6ES7 648-0CB00-0YA0<br />

incl. 4-way USB hub A 6ES7 648-0CD00-0YA0<br />

SIMATIC <strong>PC</strong> USB mouse<br />

(optical, 3-button)<br />

for PG and <strong>PC</strong> with PS/2-adapter<br />

A 6ES7 790-0AA01-0XA0<br />

SIMATIC I<strong>PC</strong> USB FlashDrive<br />

8 GB, USB 2.0, metal enclosure,<br />

bootable<br />

A 6ES7 648-0DC50-0AA0<br />

SIMATIC I<strong>PC</strong> Service USB<br />

FlashDrive<br />

8 GB, USB 2.0, metal enclosure,<br />

bootable, with BIOS-Manager,<br />

Image & Partition Creator preinstalled,<br />

incl. CD<br />

B 6AV7 672-8JD01-0AA0<br />

Communication products see expansion components<br />

RMOS real-time operating<br />

system<br />

see expansion components<br />

Software Packages with SIMATIC WinCC flexible,<br />

SIMATIC WinCC and SIMATIC WinAC RTX (F) can be ordered<br />

together with the SIMATIC I<strong>PC</strong> with a price advantage.<br />

More information under "Embedded Bundles / Packages for<br />

industrial <strong>PC</strong>s".<br />

5/25<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>547C<br />

■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical<br />

specifications.<br />

Technical data of the telescopic rails<br />

Ultimate load per pair, min. 30 kg<br />

Full extraction length, min. 470 mm<br />

Rail thickness, max. 9.7 mm<br />

Fixing screws M5 x 6 mm<br />

The fixing screws of the telescopic rails may not protrude more<br />

than 5 mm into the enclosure.<br />

The enclosure is prepared for the following telescopic rails:<br />

Co. Rittal: Type 3659.1<strong>80</strong> for 600 mm cabinet /<br />

Type RP 3659.190 for <strong>80</strong>0 mm cabinet<br />

Co. Schroff: Type <strong>2011</strong>0-072<br />

5/26<br />

14.3<br />

481.4<br />

465.1<br />

433.5<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

445.5<br />

101.6<br />

37.5<br />

18.5<br />

176.5<br />

489<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00452<br />

■ More information<br />

Further information can be found on the Internet at:<br />

www.siemens.com/simatic-pc


■ Overview<br />

The SIMATIC I<strong>PC</strong>647C is a very rugged, high-performance<br />

industrial <strong>PC</strong> in 19" rack design (2 HU) with excellent industrial<br />

functionality.<br />

It offers:<br />

extreme compactness<br />

extreme ruggedness<br />

Intel Core i technology<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>647C<br />

Extremely compact and industry-compatible for 24-hour<br />

continuous use in an industrial environment<br />

Compact enclosure design (2 HMs)<br />

Suitable for installation in space-saving control cabinets only<br />

500 mm deep<br />

Maximum processor performance (in maximum configuration)<br />

without loss of power (throttling) at ambient temperatures of<br />

up to 50 °C<br />

Distinct product design with new front design and fullycoated,<br />

dirt-resistant surfaces<br />

All-metal housing with high EMC for use in industrial<br />

environment<br />

Dust protection thanks to overpressure ventilation concept<br />

with fan on the front and dust filter<br />

Special hard disk holders and card retainers for protection<br />

against vibration and shock<br />

High productivity thanks to faster data processing<br />

New 2010 Intel® Core processors – with Turbo Boost,<br />

Hyper-Threading and Virtualization technology<br />

Memory and graphics controller integrated into processor for<br />

extraordinary memory and graphic performance<br />

Maximum performance (e. g. Intel QM57 Express Chipset,<br />

DDR3 memory with the support of Dual Channel technology)<br />

High data transfer rates (e. g. with Serial ATA hard disks, dual<br />

Gigabit Ethernet)<br />

Reduction in downtimes through high system availability<br />

Secure 24-hour operation (high MTBF, variable-speed fan)<br />

Efficient self-diagnostics (status display for Ethernet and<br />

PROFIBUS; alarm indication for fan, temperature, watchdog<br />

and hard disks in RAID1 configuration, SIMATIC I<strong>PC</strong><br />

DiagMonitor)<br />

High degree of data security due to RAID1 (mirror disk<br />

system)<br />

Rapid identification and replacement of the hard disk in the<br />

event of a fault (e. g. front LEDs for HDD alarm in RAID1<br />

configuration)<br />

"Hot swap" removable frame in RAID configuration<br />

(replacement of hard disk during operation)<br />

Solid-state drive (SSD) in single level cell (SLC) architecture<br />

and ECC memory (optional)<br />

Securing of the replaceable components at the front<br />

(e. g. USB software dongle) against unauthorized access by<br />

means of a lockable door<br />

Locked fan cover: Filter mat and front fan can only be<br />

replaced when front door is open<br />

The enclosure cover can only be opened if the front door is<br />

open<br />

Service-friendly device setup (modifications, service)<br />

5/27<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>647C<br />

■ Benefits (continued)<br />

Cost reductions through high investment security<br />

Availability of 3 to 5 years, guaranteed availability of spare<br />

parts for 5 years<br />

System-tested with SIMATIC components<br />

Certification for worldwide marketing (cULus)<br />

Support for legacy interfaces (PS/2, COM, LPT)<br />

Installation compatible for many device generations<br />

Worldwide service and support<br />

Reduced costs due to time savings for commissioning,<br />

operation and servicing<br />

High degree of flexibility and expansion thanks to integrated<br />

interfaces and up to 3 slots (<strong>PC</strong>I and <strong>PC</strong>I Express)<br />

Preinstalled and activated operating system<br />

AMT (Intel Active Management Technology) functionality for<br />

remote access to I<strong>PC</strong> (remote maintenance)<br />

Fast restoration of the delivery status of the HDD thanks to<br />

restore DVD<br />

Low noise output thanks to controlled fan<br />

Universal implementation as an industrial workstation or<br />

server<br />

PROFIBUS or PROFINET interface and RAID1 controller<br />

onboard (optional)<br />

2 x LAN 10/100/1000 Mbit/s connections<br />

(Gbit LAN with teaming capability)<br />

Flexible application options in locations with telescopic rails or<br />

as desktop industrial <strong>PC</strong><br />

■ Application<br />

The SIMATIC I<strong>PC</strong>647C provides mechanical engineers, plant<br />

engineers, and control cabinet manufacturers with a high-performance,<br />

extremely flexible 19" rack <strong>PC</strong> platform for machine-level<br />

industrial use:<br />

Measuring, open-loop and closed-loop control of process and<br />

machine data<br />

Visualization of production processes<br />

Image processing and editing in the context of quality<br />

inspections<br />

Data recording and management<br />

Server applications<br />

The SIMATIC I<strong>PC</strong>647C has the CE mark for use in the industrial<br />

sector as well as in residential and commercial areas, and small<br />

businesses. In addition to industrial applications, it can therefore<br />

also be used in building services automation or in facilities open<br />

to the public.<br />

The SIMATIC Rack I<strong>PC</strong>s can be ordered in connection with<br />

WinCC flexible or WinCC as SIMATIC HMI packages at favorable<br />

prices.<br />

5/28<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Design<br />

Basic design<br />

All-metal 19" enclosure (2 HMs) for high mechanical<br />

robustness (vibration/shock) and high EMC<br />

For mounting in a horizontal position and prepared for the<br />

mounting of telescopic rails<br />

Lockable front door for authorized access (access protection)<br />

to swap media at the front, operating controls (Reset, Power),<br />

USB interface, front fan and dust filter<br />

Card retainer for <strong>PC</strong> modules for safe operation and transport<br />

(vibration, shock)<br />

Opening of the enclosure cover with only one screw and<br />

replacement of <strong>PC</strong> components (e. g. <strong>PC</strong> cards or HDD) with<br />

a single tool<br />

Front fan and dust filter can be replaced without tools<br />

Dust protection through pressurized cooling with front fan<br />

mounted in roller bearing via filter<br />

3 slots for installing drives<br />

- Front: 2 x HDD swap frames (low profile); 1 x optical drive<br />

(slimline) or 1x CF drive<br />

- Internal: 2 x 3.5" (in optional, shock and vibration-damped<br />

disk-drive support) as an alternative to swap frames<br />

Graphics onboard on the <strong>PC</strong>I-Express bus, Intel GMA HD<br />

integrated in the processor, up to 2048 x 1536 pixels, 60 Hz,<br />

16 bit colors<br />

Interfaces:<br />

- 2 x LAN 10/100/1000 Mbit/s Ethernet interface<br />

(RJ45, team capability)<br />

- 4 x USB 2.0 at the rear, 2 x USB 2.0 at the front<br />

(one of which can be used when door is closed), 1 x internal,<br />

e. g. for software dongle<br />

- 2 x PS/2, COM1, COM2, LPT1, DVI-I<br />

- Audio: Line Out, Micro<br />

3 spare slots for expansions (all long):<br />

-1 x <strong>PC</strong>I<br />

- 1 x <strong>PC</strong>I-Express x16<br />

- 1 x <strong>PC</strong>I-Express x8 (4-lane)<br />

Power supply: 100 ... 240 V AC, 50 ... 60 Hz<br />

Design versions<br />

Processor:<br />

- Intel Core i7-610E (2C/4T, 2.53 GHz, 4 MB cache, Turbo<br />

Boost, VT-d, iAMT, EM64T)<br />

- Intel Core i5-520E (2C/4T, 2.4 GHz, 3 MB cache, Turbo<br />

Boost, VT-d, iAMT, EM64T)<br />

- Intel Core i3-330E (2C/4T, 2.13 GHz, 3 MB cache, EM64T)<br />

Main memory expansion<br />

from 1 GB up to 8 GB, DDR3 1066 SDRAM (configured as dual<br />

channel for the highest performance from 2 GB upwards)<br />

- ECC memory<br />

Memory tip:<br />

a 64-bit operating system is required to use a memory<br />

expansion with more than 4 GB. In configurations with at<br />

least 4 GB, the visible memory can be reduced to about<br />

3.5 GB or less (with 32-bit operating systems) and in<br />

configurations with 8 GB, the visible memory can be<br />

reduced to about 7.5 GB or less.


■ Design (continued)<br />

Fieldbus onboard:<br />

- PROFIBUS/MPI, CP 5611-compatible or PROFINET,<br />

3 x RJ45, CP 1616-compatible<br />

Bus modules with 3 spare slots (2 x <strong>PC</strong>I, 1 x <strong>PC</strong>I-Express x16)<br />

Graphic expansion:<br />

- <strong>PC</strong>I-Express graphic card x16, (dual head with display port:<br />

2 x VGA or 2 x DVI-D via adapter), 256 MB, up to<br />

2 048 x 1 536 pixels, 75 Hz, 32-bit colors<br />

- Adapter cable (DVI-I to VGA) for the onboard graphic<br />

interface (1 x VGA) for connecting an analog monitor<br />

SATA 3.5" hard disks with NCQ technology or SATA 2.5"<br />

solid-state drive:<br />

- Mounted internally on the permanent hard disk support:<br />

- 1x 32 GB SSD in single level cell (SLC) architecture<br />

- Mounted internally in vibration/shock-absorbing hard-disk<br />

support or at the front in a swap frame (hot-swap in RAID1<br />

configuration):<br />

- 1 x 250 GB<br />

- 1 x or 2 x 500 GB<br />

- RAID1, 500 GB (2 x 500 GB, mirror disks), RAID controller<br />

onboard<br />

Optical drive: DVD+/-R/RW, slimline<br />

CompactFlash drive, at front<br />

Country-specific power cable<br />

Preinstalled operating systems:<br />

- Windows XP Professional multi language, 32 bit<br />

- Windows 7 Ultimate multi language, 32 bit<br />

- Windows Server 2008 Standard Edition incl. 5 Client multi<br />

language, 32-bit<br />

SIMATIC I<strong>PC</strong> DiagMonitor 1)<br />

SIMATIC <strong>PC</strong>/PG Image Creator 1)<br />

1) Further information can be found under "Expansion components".<br />

Front view of SIMATIC I<strong>PC</strong>647C, with open front door<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Function<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>647C<br />

Multi Core processor technology<br />

Thanks to the use of two processor cores with hyper-threading,<br />

the Core i processors are ideally suited to multi-thread application<br />

programs and multitasking. Several demanding applications<br />

- such as visualization applications with demanding<br />

graphics or programs executing extensive calculations - can be<br />

executed at the same time to enhance the response time of the<br />

system. Thanks to energy-optimized Multi Core technology and<br />

outstanding energy-saving properties, the Intel Core i<br />

processors operate without any loss of performance even at<br />

increased temperatures up to 50 °C in demanding applications.<br />

Multi-display technology<br />

The multi-display architecture with its modern functions for<br />

desktop and application management supports working with<br />

several screens and therefore considerably enhances productivity.<br />

The SIMATIC I<strong>PC</strong>647C with an optional dual-head graphic<br />

card (<strong>PC</strong>I-Express x16) is optimized for industrial multi-display<br />

environments. The following multidisplay modes are supported:<br />

Native DualView, Span or Big Desktop, Clone.<br />

Connection options: 2 x VGA or 2 x DVI-D<br />

Monitoring functions<br />

Integrated monitoring functions (program execution (watchdog),<br />

temperature, fan speed and hard disk status in RAID configuration).<br />

Expanded diagnostics/messages via Ethernet, e-mail,<br />

text message and for direct transfer to SIMATIC software via<br />

O<strong>PC</strong> (optionally via SIMATIC I<strong>PC</strong> DiagMonitor):<br />

Runtime meter<br />

Hard disk status<br />

System status (Heart Beat)<br />

Automatic logging of all alarms by means of a log file<br />

Capability for central monitoring of networked SIMATIC <strong>PC</strong>s<br />

RAID1 (RAID controller onboard) for automatic data mirroring<br />

on two SATA hard disks<br />

AMT functionality (Intel Active Management Technology)<br />

This feature allows remote access to the I<strong>PC</strong> for diagnostics and<br />

troubleshooting (service work) even with the operating system<br />

shut down:<br />

Controlled startup/shutdown of the I<strong>PC</strong><br />

Access to BIOS settings and BIOS update<br />

Measures by means of remote access in the event of a fault,<br />

e. g. reboot<br />

Software updates from integrated ISO image<br />

RAID controller onboard<br />

RAID1 (mirroring) for automatic data mirroring on two SATA<br />

hard disks<br />

5/29<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>647C<br />

■ Integration<br />

Integrated interfaces:<br />

Ethernet<br />

The two integrated Gigabit Ethernet interfaces (10/100/<br />

1000 Mbit/s) can be used for IT communication and for data<br />

exchange with programmable controllers such as SIMATIC S7<br />

(with the "SOFTNET S7" software package).<br />

PROFIBUS<br />

The optional floating PROFIBUS interface (12 Mbit/s) can be<br />

used to connect distributed field devices or for coupling to the<br />

SIMATIC S7 (with the "SOFTNET for PROFIBUS" software<br />

package).<br />

PROFINET<br />

The optional PROFINET interface can be used for connecting<br />

distributed field devices or for controlling drives.<br />

Further interfaces<br />

For the connection of further I/O devices, 2 free slots are<br />

available for <strong>PC</strong> modules, 1 free <strong>PC</strong>I-Express x16 slot for<br />

optional graphic expansions, as well as seven USB 2.0<br />

interfaces, two serial interfaces, and one parallel interface.<br />

5/30<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Technical specifications<br />

SIMATIC I<strong>PC</strong>647C<br />

General features<br />

Design 19" rack, 2 HMs, external coating<br />

Processor Intel Core i7-610E<br />

(2C/4T, 2.53 GHz, 4 MB cache,<br />

Turbo Boost, VT-d, iAMT, EM64T)<br />

Intel Core i5-520E<br />

(2C/4T, 2.4 GHz, 3 MB cache,<br />

Turbo Boost, VT-d, iAMT, EM64T)<br />

Intel Core i3-330E<br />

(2C/4T, 2.13 GHz, 3 MB cache,<br />

EM64T)<br />

Chipset Intel QM57<br />

Main memory from 1 GB DDR3 1066 SDRAM<br />

Dual channel support<br />

2 DIMM base<br />

Expandable up to 8 GB, ECC<br />

optional 3)<br />

Spare slots for expansions (all 2 x <strong>PC</strong>I<br />

long)<br />

1 x <strong>PC</strong>I-Express x16<br />

or<br />

1 x <strong>PC</strong>I<br />

1 x <strong>PC</strong>I-Express x8 (4-lane)<br />

1 x <strong>PC</strong>I-Express x16<br />

Graphics Onboard Intel GMA HD graphics<br />

controller integrated into processor;<br />

dynamic video memory; up to<br />

2048 x 1536 pixels with 75 Hz<br />

refresh rate and 16-bit colors<br />

<strong>PC</strong>I-Express graphic card (Dual<br />

Head: 2 x VGA or 2 x DVI-D via<br />

display port adapter) in the <strong>PC</strong>Ie x16<br />

slot; 256 MB; up to 2048 x<br />

1536 pixels with 75 Hz refresh rate<br />

and 32-bit colors (optional)<br />

Operating system Without<br />

Preinstalled, activated, and<br />

supplied on restore DVD<br />

Windows XP Professional MUI,<br />

32-bit<br />

Windows 7 Ultimate MUI, 32-bit<br />

Windows Server 2008 incl. 5 Client<br />

MUI, 32-bit<br />

MUI: Multilanguage User Interface;<br />

5 languages (English, French,<br />

German, Italian, Spanish)<br />

Project-specific on request 1)<br />

Others<br />

Power supply 100 ... 240 V AC, 50 ... 60 Hz; with<br />

bridging of temporary power failures<br />

according to NAMUR: max. 20 ms at<br />

0.85% rated voltage


■ Technical specifications (continued)<br />

Drives<br />

SATA 3.5" hard disk<br />

Mounted in internal shock/vibration-<br />

or solid-state drive, SATA 2.25" resistant disk drive support<br />

250GB<br />

500GB<br />

2 x 500 GB<br />

500 GB RAID1 2) ,<br />

2 x 500 GB (mirror disks)<br />

Installation in front drive support<br />

32 GB SSD, SLC<br />

Mounted in front drive support in<br />

swap frame (low profile)<br />

250GB<br />

500GB<br />

2 x 500 GB<br />

500 GB RAID1 2) SIMATIC I<strong>PC</strong>647C<br />

,<br />

2 x 500 GB (mirror disks),<br />

"hot swap"<br />

32 GB SSD, SLC<br />

DVD+/-R/RW, slimline 8 x 8 x 6 x (DVD media)<br />

24 x 24 x 24 x (CD media)<br />

Slots for drives Front:<br />

2 x low profile swap frames<br />

(for 3.5" HDD)<br />

1 x 12.7 mm slimline<br />

(for ODD or CF drive)<br />

Internal:<br />

2 x 3.5" as an alternative to swap<br />

frames (in the optional, shock and<br />

vibration-damped drive support)<br />

Interfaces<br />

PROFINET 3 x RJ45 (CP 1616-compatible),<br />

optional<br />

PROFIBUS/MPI 12 Mbit/s (isolated, compatible with<br />

CP 5611), optional<br />

Ethernet 2 x 10/100/1000 Mbit/s<br />

(RJ45, team-capability)<br />

USB 2.0 2 x front (high current)<br />

4 x rear (high current)<br />

1 x internal (high current),<br />

e. g. for USB dongle<br />

Serial 9-pin COM1 (V.24)<br />

9-pin COM2 (V.24)<br />

Parallel LPT1<br />

VGA 1 x<br />

Keyboard PS/2<br />

Mouse PS/2<br />

Audio 1 x Line Out; 1 x Micro<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>647C<br />

SIMATIC I<strong>PC</strong>647C<br />

Monitoring functions<br />

Basic functionality Message locally via DiagBase<br />

software<br />

Temperature Overshoot/undershoot of permissible<br />

operating temperature range<br />

Messages can be evaluated by the<br />

application program<br />

Fan Speed monitoring<br />

2 x housing fan (front)<br />

1 x power supply fan<br />

Watchdog Monitoring of program execution<br />

Monitoring time can be parameterized<br />

in software<br />

Restart can be parameterized<br />

in the event of a fault<br />

Messages can be evaluated by<br />

the application program<br />

Monitoring functions via the SIMATIC I<strong>PC</strong> DiagMonitor (optional)<br />

network<br />

Version 4.2 and higher<br />

Remote monitoring capability for:<br />

Watchdog<br />

Temperature<br />

Fan speed<br />

Hard disk monitoring (SMART)<br />

System/Ethernet monitoring<br />

(Heart Beat)<br />

Communication:<br />

Ethernet interface (SNMP protocol)<br />

O<strong>PC</strong> for integration in SIMATIC<br />

software<br />

Configuration of client/server architectures<br />

Structure of log files<br />

Front LEDs POWER (internal power supply unit,<br />

<strong>PC</strong> switched on)<br />

HARDDISK (access to hard disk)<br />

ETHERNET1 (Ethernet status,<br />

"Heart Beat")<br />

ETHERNET2 (Ethernet status,<br />

"Heart Beat")<br />

PROFIBUS/MPI (PROFIBUS status)<br />

SF PROFINET (PROFINET status)<br />

WATCHDOG (ready/fault indication)<br />

TEMP (temperature status)<br />

FAN (fan speed monitoring)<br />

HDD1 ALARM (hard disk alarm in<br />

conjunction with RAID1 and<br />

monitoring software)<br />

HDD2 ALARM (hard disk alarm in<br />

conjunction with RAID1 and<br />

monitoring software)<br />

5/31<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>647C<br />

■ Technical specifications (continued)<br />

Ambient conditions<br />

Degree of protection IP41 at the front, IP20 at the rear acc.<br />

to EN 60529<br />

Dust protection With front door closed: G2 EN 779,<br />

99% of particles > 0.5 mm are held<br />

back<br />

Protection class Protection class I according to<br />

IEC 61140<br />

Vibration load during operation EN 60068-2-6, 10 cycles<br />

Internal mounting of the hard disk<br />

drives in optional, internal drive<br />

supports:<br />

10 ... 58 Hz: 0.0375 mm;<br />

58 ... 500 Hz: 5 m/s2 (ca. 0.5 g)<br />

Note:<br />

Limitations when DVD+/-RW and<br />

HDD are operated in a swap frame<br />

Shock load during operation EN 60068-2-27, IEC 60068-2-29<br />

Internal mounting of the hard disk<br />

drives in optional, internal drive<br />

supports:<br />

Half-sine: 50 m/s2 SIMATIC I<strong>PC</strong>647C<br />

, 30 ms (ca. 5 g),<br />

100 shocks per axis<br />

Note:<br />

Limitations when DVD+/-RW and<br />

HDD are operated in a swap frame<br />

Electromagnetic<br />

compatibility (EMC)<br />

Radiated interference (AC) EN 61000-6-3, EN 61000-3-3,<br />

EN 61000-3-2 Class D; FCC Class A<br />

Immunity to conducted inter- ± 2 kV (IEC 61000-4-4, burst)<br />

ference on the supply lines ± 1 kV (IEC 61000-4-5, symm. surge)<br />

± 2 kV (IEC 61000-4-5, asymm.<br />

surge)<br />

5/32<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Immunity to interference on<br />

signal lines<br />

SIMATIC I<strong>PC</strong>647C<br />

± 1 kV (IEC 61000-4-4, burst, length<br />

< 30 m)<br />

± 2 kV (IEC 61000-4-4, symm. surge,<br />

length > 30 m)<br />

± 2 kV (IEC 61000-4-5, asymm.<br />

surge, length > 30 m)<br />

Immunity to static discharge ± 6 kV, contact discharge<br />

(IEC 61000-4-2)<br />

± 8 kV, air discharge (IEC 61000-4-2)<br />

Immunity to high radio<br />

frequency interference<br />

1 V/m <strong>80</strong>% AM 1 kHz;<br />

2 ... 2.7 GHz (IEC 61000-4-3)<br />

10 V/m <strong>80</strong>% AM 1 kHz;<br />

<strong>80</strong> MHz - 1 GHz and 1.4 GHz - 2 GHz<br />

(IEC 61000-4-3);<br />

10 V, 10 kHz to <strong>80</strong> MHz<br />

(IEC 61000-4-6)<br />

Immunity to magnetic fields 100 A/m, 50/60 Hz (IEC 61000-4-8)<br />

Ambient temperature during<br />

operation<br />

Relative humidity during<br />

operation<br />

Approvals<br />

5…50°C<br />

Note:<br />

Limitations when DVD+/-RW and<br />

HDD are operated in a swap frame<br />

5 ... 85% at 30 °C (no condensation)<br />

Safety regulations IEC 60950-1 Second Edition,<br />

EN 60950-1, UL 60950, CSA C22.2<br />

No 60950<br />

Approvals cULus 60950<br />

CE mark Use in industry:<br />

Noise immunity: EN 61000-6-2:2005<br />

Use in domestic environments:<br />

Emitted interference:<br />

EN 61000-6-3:2007<br />

Dimensions and weights<br />

Mounting dimensions<br />

430x88x445<br />

(W x H x D, in mm)<br />

Weight Minimum 16 kg, maximum 23 kg<br />

1) Suitable for specific LINUX versions in accordance with the specifications<br />

of the <strong>Siemens</strong> manufacturer's declaration "Suited for LINUX"<br />

(LINUX is a trademark of Linus Torvald).<br />

2) SATA RAID controller on board in Intel chipset<br />

3)<br />

Memory information:<br />

In order to use a memory expansion with more than 4 GB, a 64-bit<br />

operating system is required. In configurations with at least 4 GB, the<br />

visible memory can be reduced to about 3.5 GB or less (with 32-bit<br />

operating systems) and in configurations with 8 GB, the visible<br />

memory can be reduced to about 7.5 GB or less.<br />

Note regarding SIMATIC <strong>PC</strong> operating system licenses:<br />

The accompanying operating system license is only valid for<br />

installation on the supplied SIMATIC <strong>PC</strong>. Installation can only be<br />

performed on these SIMATIC systems in accordance with<br />

Microsoft OEM licensing regulations.


<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

■ Ordering data Order No. Order No.<br />

Configuration 1)<br />

Configuration 1)<br />

1<br />

SIMATIC I<strong>PC</strong>647C<br />

Interfaces:<br />

2 x 10/100/1000 Mbit/s Ethernet<br />

(RJ45); 1 x graphic (DVI-I);<br />

2 x COM; 1 x LPT; 2 x PS/2;<br />

4 x USB 2.0 at rear, 2 x USB 2.0 at<br />

front; 1 x USB 2.0 internal; audio;<br />

temperature and fan monitoring,<br />

watchdog; card retainer<br />

Processor/motherboard<br />

D 6AG4 112 - 11 7 7 7 7 - 7 7 7 7<br />

Core i3-330E (2C/4T, 2.13 GHz,<br />

3 MB cache), motherboard<br />

without fieldbus<br />

G<br />

Core i3-330E (2C/4T, 2.13 GHz,<br />

3 MB cache), motherboard with<br />

PROFIBUS/MPI<br />

H<br />

Core i3-330E (2C/4T; 2.13 GHz,<br />

3 MB cache), motherboard with<br />

PROFINET (3 x RJ45,<br />

CP 1616-compatible) 2)<br />

J<br />

Core i5-520E (2C/4T, 2.4 GHz,<br />

3 MB cache, TB, iAMT, VT),<br />

motherboard without fieldbus<br />

K<br />

Core i5-520E (2C/4T, 2.4 GHz,<br />

3 MB cache, TB, iAMT, VT),<br />

motherboard with PROFIBUS/<br />

MPI<br />

L<br />

Core i5-520E (2C/4T; 2.4 GHz,<br />

3 MB cache, TB, iAMT, VT),<br />

motherboard with PROFINET<br />

(3 x RJ45,<br />

CP 1616-compatible) 2)<br />

M<br />

Core i7-610E (2C/4T, 2.53 GHz,<br />

4 MB cache, TB, iAMT, VT),<br />

motherboard without field bus<br />

N<br />

Core i7-610E (2C/4T, 2.53 GHz,<br />

4 MB cache, TB, iAMT, VT),<br />

motherboard with PROFIBUS/<br />

MPI<br />

P<br />

Core i7-610E (2C/4T; 2.53 GHz,<br />

4 MB cache, TB, iAMT, VT),<br />

motherboard with PROFINET<br />

(3 x RJ45,<br />

CP 1616-compatible) 2)<br />

R<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

1) For an up-to-date overview, see the SIMATIC <strong>PC</strong> online configurator<br />

at: www.siemens.com/ipc-configurator<br />

2) Not in combination with Windows 7 and Windows Server 2008<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>647C<br />

SIMATIC I<strong>PC</strong>647C<br />

(continued)<br />

Hard disks:<br />

D 6AG4 112 - 1 7 777 - 7 7 7 7<br />

250 GB HDD SATA; 0.5 g<br />

vibration, 5 g shock, internal<br />

A<br />

500 GB HDD SATA; 0.5 g<br />

vibration, 5 g shock, internal<br />

B<br />

2 x 500 GB HDD SATA; 0.5 g<br />

vibration, 5 g shock, internal<br />

C<br />

RAID1 500 GB (2 x 250 GB HDD<br />

SATA, mirror disks); 0.5 g<br />

vibration, 5 g shock, internal<br />

D<br />

250 GB HDD SATA in swap<br />

frame; front<br />

H<br />

500 GB HDD SATA in swap<br />

frame; front<br />

K<br />

2 x 500 GB HDD SATA in swap<br />

frame; front<br />

M<br />

RAID1 500 GB (2 x 250 GB HDD<br />

SATA) in swap frame, for hot<br />

swapping; front<br />

P<br />

32 GB SSD (SLC) SATA, internal S<br />

32 GB SSD (SLC) SATA in swap<br />

frame; front<br />

Memory expansion:<br />

T<br />

1 GB DDR3 SDRAM (1 x 1 GB),<br />

single channel<br />

0<br />

2 GB DDR3 SDRAM (1 x 2 GB),<br />

single channel<br />

1<br />

4 GB DDR3 SDRAM (2 x 2 GB),<br />

dual channel<br />

2<br />

6 GB DDR3 SDRAM (1 x 2 GB,<br />

1 x 4 GB), dual channel<br />

3<br />

8 GB DDR3 SDRAM (2 x 4 GB),<br />

dual channel<br />

4<br />

2 GB DDR3 SDRAM (2 x 1 GB),<br />

dual channel<br />

5<br />

4 GB DDR3 SDRAM (2 x 2 GB),<br />

dual channel<br />

6<br />

8 GB DDR3 SDRAM (2 x 4 GB),<br />

dual channel<br />

7<br />

5/33<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>647C<br />

■ Ordering data Order No. Order No.<br />

Configuration 1)<br />

SIMATIC I<strong>PC</strong>647C<br />

(continued)<br />

Swap media:<br />

D 6AG4 112 - 1 7 7 7 7 - 7 7 7 7<br />

CompactFlash drive, at front 0<br />

DVD±RW 1<br />

without swap medium<br />

Bus module / hardware<br />

expansion<br />

8<br />

Bus modules 3 slots: 2 x <strong>PC</strong>I;<br />

1 x <strong>PC</strong>Ie x16; without hardware<br />

expansions<br />

0<br />

Bus modules 3 slots: 2 x <strong>PC</strong>I;<br />

1 x <strong>PC</strong>Ie x16; DVI-VGA adapter<br />

(1 x VGA) for onboard graphics<br />

1<br />

Bus modules 3 slots: 2 x <strong>PC</strong>I;<br />

1 x <strong>PC</strong>Ie x16 assigned; +<br />

graphic card <strong>PC</strong>Ie x16, 2 x DP<br />

(2 x DVI-D via 2 x DP-DVI<br />

adapters)<br />

2<br />

Bus modules 3 slots: 2 x <strong>PC</strong>I;<br />

1 x <strong>PC</strong>Ie x16 assigned; +<br />

graphic card <strong>PC</strong>Ie x16, 2 x DP<br />

(2 x VGA via 2 x DP-VGA<br />

adapters)<br />

3<br />

Bus modules 3 slots: 1 x <strong>PC</strong>I,<br />

1 x <strong>PC</strong>Ie x8 (4-lane); 1 x <strong>PC</strong>Ie<br />

x16; without HW expansions<br />

4<br />

Bus modules 3 slots: 1 x <strong>PC</strong>I;<br />

1 x <strong>PC</strong>Ie x8 (4-lane); 1 x <strong>PC</strong>Ie<br />

x16; DVI-VGA adapter (1 x VGA)<br />

for onboard graphics<br />

5<br />

Bus modules 3 slots: 1 x <strong>PC</strong>I;<br />

1 x <strong>PC</strong>Ie x8 (4-lane); 1 x <strong>PC</strong>Ie<br />

x16 assigned; + graphic card<br />

<strong>PC</strong>Ie x16, 2 x DP (2x DVI-D via<br />

2x DP-DVI adapters)<br />

6<br />

Bus modules 3 slots: 1 x <strong>PC</strong>I;<br />

1 x <strong>PC</strong>Ie x8 (4-lane); 1 x <strong>PC</strong>Ie<br />

x16 assigned; + graphic card<br />

<strong>PC</strong>Ie x16, 2 x DP (2x VGA via 2x<br />

DP-VGA adapters)<br />

7<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

1) For an up-to-date overview, see the SIMATIC <strong>PC</strong> online configurator<br />

at: www.siemens.com/ipc-configurator<br />

5/34<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Configuration 1)<br />

SIMATIC I<strong>PC</strong>647C<br />

(continued)<br />

Operating system<br />

(preinstalled and activated)<br />

D 6AG4 112 - 1 7 7 7 7 - 7 777<br />

Windows XP Professional, MUI<br />

(Eng, Ger, Fr, It, Sp), SP3, 32-bit<br />

B<br />

Windows 7 Ultimate, MUI<br />

(Eng, Ger, Fr, It, Sp), 32-bit<br />

E<br />

Windows Server 2008 Standard<br />

Edition incl. 5 clients, MUI<br />

(Eng, Fr, Ger, It, Sp), SP2, 32-bit<br />

P<br />

Without operating system<br />

Expansion (software)<br />

X<br />

SIMATIC I<strong>PC</strong> DiagMonitor 4.2<br />

included<br />

A<br />

SIMATIC I<strong>PC</strong> Image Creator<br />

software 3.1 included<br />

B<br />

SIMATIC I<strong>PC</strong> DiagMonitor 4.2<br />

and Image Creator Software 3.1<br />

included<br />

C<br />

Without software<br />

Power supply, with countryspecific<br />

cable:<br />

X<br />

100/240 V AC industrial power<br />

supply with Namur; power cable<br />

for Europe<br />

0<br />

100/240 V AC industrial power<br />

supply with Namur; power cable<br />

for United Kingdom<br />

100/240 V AC industrial power<br />

supply with Namur; power cable<br />

for Switzerland<br />

100/240 V AC industrial power<br />

supply with Namur; power cable<br />

for USA<br />

100/240 V AC industrial power<br />

supply with Namur; power cable<br />

for Italy<br />

100/240 V AC industrial power<br />

supply with Namur; power cable<br />

for China<br />

1<br />

2<br />

3<br />

4<br />

5


<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>647C<br />

■ Ordering data Order No. Order No.<br />

Accessories<br />

Retainer 6ES7 648-1AA00-0XK0<br />

Memory expansion<br />

for pin assignment of the internal<br />

1 GB DDR3 1066 SDRAM, A 6ES7 648-2AJ40-0KA0<br />

USB port<br />

DIMM<br />

2 GB DDR3 1066 SDRAM,<br />

DIMM<br />

A 6ES7 648-2AJ50-0KA0<br />

SIMATIC <strong>PC</strong> keyboard<br />

German/international,<br />

4 GB DDR3 1066 SDRAM, A 6ES7 648-2AJ60-0KA0<br />

USB port 6ES7 648-0CB00-0YA0<br />

DIMM<br />

incl. 4-way USB hub A 6ES7 648-0CD00-0YA0<br />

1 GB DDR3 1066 SDRAM,<br />

DIMM, ECC<br />

2 GB DDR3 1066 SDRAM,<br />

DIMM, ECC<br />

A<br />

A<br />

6ES7 648-2AJ40-1KA0<br />

6ES7 648-2AJ50-1KA0<br />

SIMATIC <strong>PC</strong> mouse A<br />

(optical, 3-button) for PG and <strong>PC</strong><br />

with adapter<br />

6ES7 790-0AA01-0XA0<br />

4 GB DDR3 1066 SDRAM, A<br />

DIMM, ECC<br />

Hard disk slide-in unit for swap<br />

frame<br />

SIMATIC <strong>PC</strong> accessories, slide-in<br />

HDD swap frame, low-profile, for<br />

3.5" hard disk, serial ATA (without<br />

hard disk)<br />

Power cable, straight, 3 m long<br />

6ES7 648-2AJ60-1KA0<br />

6ES7 648-0EG00-1BA0<br />

SIMATIC I<strong>PC</strong> USB FlashDrive<br />

8 GB, USB 2.0, metal enclosure,<br />

bootable<br />

SIMATIC I<strong>PC</strong> Service USB<br />

FlashDrive<br />

8 GB, USB 2.0, metal enclosure,<br />

bootable, with BIOS-Manager,<br />

Image & Partition Creator preinstalled,<br />

incl. CD<br />

A<br />

B<br />

6ES7 648-0DC50-0AA0<br />

6AV7 672-8JD01-0AA0<br />

Austria, Belgium, Finland,<br />

France, Germany, Netherlands,<br />

6ES7 900-0AA00-0XA0<br />

Communication products see expansion components<br />

Spain, Sweden<br />

RMOS real-time operating see expansion components<br />

United Kingdom 6ES7 900-0BA00-0XA0<br />

system<br />

Switzerland 6ES7 900-0CA00-0XA0<br />

USA 6ES7 900-0DA00-0XA0<br />

Italy 6ES7 900-0EA00-0XA0<br />

China 6ES7 900-0FA00-0XA0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

Note:<br />

Software Packages with SIMATIC WinCC flexible,<br />

SIMATIC WinCC and SIMATIC WinAC RTX (F) can be ordered<br />

together with the SIMATIC I<strong>PC</strong> with a price advantage.<br />

More information under "Embedded Bundles / Packages for<br />

industrial <strong>PC</strong>s".<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

5/35<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>647C<br />

■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical<br />

specifications.<br />

8.2<br />

Technical data for telescopic rails<br />

Carrying capacity per pair, min. 30 kg<br />

Extended length when fully<br />

withdrawn, min.<br />

470 mm<br />

Rail thickness, max. 9.7 mm<br />

Fixing screws M5 x 6 mm<br />

The fixing screws of the telescopic rails should not project more<br />

than 5 mm into the enclosure.<br />

The enclosure is prepared for the following telescopic rails:<br />

Co. Rittal: Type 3659.1<strong>80</strong> for 600 mm cabinet /<br />

Type RP 3659.190 for <strong>80</strong>0 mm cabinet<br />

5/36<br />

481.4<br />

465<br />

429.9<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

444.6<br />

76.2<br />

5.7<br />

487.1<br />

87.6<br />

G_<strong>ST</strong><strong>80</strong>_XX_00453 © <strong>Siemens</strong> AG <strong>2011</strong><br />

■ More information<br />

Further information can be found on the Internet at:<br />

www.siemens.com/simatic-pc


■ Overview<br />

The SIMATIC I<strong>PC</strong>847C is a very robust, high-performance industrial<br />

<strong>PC</strong> in 19" rack design (4 HU) with excellent industrial<br />

functionality.<br />

It offers:<br />

maximum expandability<br />

extreme ruggedness<br />

Intel Core i technology<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>847C<br />

Maximum industrial compatibility and compactness<br />

for 24-hour use in an industrial environment<br />

Maximum processor performance (in maximum configuration)<br />

without loss of power (throttling) at ambient temperatures of up<br />

to 50 °C<br />

Distinct product design with new front design and fullycoated,<br />

dirt-resistant surfaces<br />

All-metal housing with high EMC for use in industrial<br />

environment<br />

Suitable for installing in space-saving control cabinets only<br />

500 mm deep<br />

Dust protection thanks to overpressure ventilation concept<br />

with fan on the front and dust filter<br />

Special hard disk holders and card retainers for protection<br />

against vibration and shock<br />

High productivity thanks to faster data processing<br />

New 2010 Intel ® Core processors – with Turbo-Boost,<br />

Hyper-Threading and Virtualization technology<br />

Memory and graphics controller integrated into processor for<br />

extraordinary memory and graphic performance<br />

Maximum performance (e. g. Intel QM57 Express Chipset,<br />

DDR3 memory with the support of Dual Channel technology)<br />

High data transfer rates (e. g. with Serial ATA hard disks, dual<br />

Gigabit Ethernet)<br />

Reduction in downtimes through high system availability<br />

Secure 24-hour operation (high MTBF, variable-speed fan)<br />

Efficient self-diagnostics (status display for Ethernet and<br />

PROFIBUS; alarm indication for fan, temperature, watchdog<br />

and hard disks in RAID1/5 configurations, SIMATIC <strong>PC</strong><br />

DiagMonitor)<br />

High degree of data security due to RAID1 (mirror disk<br />

system) or RAID5 (striping with parity)<br />

Rapid identification and replacement of the hard disk in the<br />

event of a fault (e. g. front LEDs for HDD alarm in RAID<br />

configurations)<br />

"Hot swap" removable frame in RAID configurations<br />

(replacement of hard disk during operation)<br />

Solid-state drive (SSD) in single level cell (SLC) architecture<br />

and ECC memory (optional)<br />

Redundant power supply with "hot swap" functionality<br />

(replacement of power supply module during operation)<br />

Securing of the replaceable components at the front<br />

(e. g. USB software dongle) against unauthorized access by<br />

means of a lockable door<br />

Locked fan cover: Filter mat and front fan can only be<br />

replaced when front door is open<br />

The enclosure cover can only be opened if the front door is<br />

open<br />

Service-friendly device setup (modifications, service)<br />

5/37<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>847C<br />

■ Benefits (continued)<br />

Cost reductions through high investment security<br />

Platform with long-term stability and embedded Intel<br />

components<br />

Availability of 3 to 5 years, guaranteed availability of spare<br />

parts for 5 years<br />

System-tested with SIMATIC components<br />

Certification for worldwide marketing (cULus)<br />

Support for legacy interfaces (PS/2, COM, LPT)<br />

Installation compatible for many device generations<br />

Worldwide service and support<br />

Reduced costs due to time savings for commissioning,<br />

operation and servicing<br />

High degree of flexibility and expandability thanks to<br />

integrated interfaces and up to 11 slots (<strong>PC</strong>I and <strong>PC</strong>I Express)<br />

Preinstalled and activated operating system<br />

AMT (Intel Active Management Technology) functionality for<br />

remote access to I<strong>PC</strong> (remote maintenance)<br />

Fast restoration of the delivery status of the HDD thanks to<br />

restore DVD<br />

Low noise output thanks to controlled fan<br />

Universal implementation as an industrial workstation or<br />

server<br />

PROFIBUS or PROFINET interface and RAID1/5 controller<br />

onboard (optional)<br />

2 x LAN 10/100/1000 Mbit/s connections (Gbit LAN with<br />

teaming capability)<br />

Flexible applications in many different positions with<br />

telescopic rails or as tower industrial <strong>PC</strong><br />

■ Application<br />

The SIMATIC I<strong>PC</strong>847C provides mechanical engineers, plant<br />

engineers, and control cabinet manufacturers with a high-performance,<br />

extremely flexible 19" rack <strong>PC</strong> platform for machine-level<br />

industrial use:<br />

Measuring, open-loop and closed-loop control of process and<br />

machine data<br />

Visualization of production processes<br />

Image processing and editing in the context of quality<br />

inspections<br />

Data recording and management<br />

The SIMATIC I<strong>PC</strong>847C has the CE mark for use in the industrial<br />

sector.<br />

The SIMATIC Rack I<strong>PC</strong>s can be ordered in connection with<br />

WinCC flexible or WinCC as SIMATIC HMI packages at favorable<br />

prices.<br />

5/38<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Design<br />

Basic design<br />

All-metal 19" enclosure (4 HMs) for high mechanical resilience<br />

(vibration/shock) and high EMC<br />

Prepared for mounting of telescopic rails<br />

Horizontal and vertical installation is possible, can be used as<br />

an industrial tower <strong>PC</strong> by using the appropriate kit<br />

Lockable front door for authorized access (access protection)<br />

to swap media at the front, operating controls (Reset, Power),<br />

USB interface, front fan and dust filter<br />

Card retainer for <strong>PC</strong> modules for safe operation and transport<br />

(vibration, shock)<br />

Opening of the enclosure cover with only one screw and<br />

replacement of <strong>PC</strong> components (e. g. <strong>PC</strong> cards or HDD) with<br />

a single tool<br />

Front fan and dust filter can be replaced without tools<br />

Dust protection by means of overpressure ventilation using<br />

bearing seated front fan through filter<br />

6 slots for installing drives<br />

- Front: 1 x 3.5"; 3 x 5.25" or 1 x 3.5"; 1 x 5.25"; 3 x HDD swap<br />

frame (low profile)<br />

- Internal: 2 x 3.5" (in the optional vibration-damping drive<br />

bracket or in the fixed hard disk support)<br />

Graphics onboard, Intel GMA HD integrated in the processor,<br />

up to 2048 x 1536 pixels, 60 Hz, 16-bit colors<br />

Interfaces:<br />

- 2 x LAN 10/100/1000 Mbit/s Ethernet interface<br />

(RJ45, team capability)<br />

- 4 x USB 2.0 at the rear, 2 x USB 2.0 at the front (one of which<br />

can be used when door is closed), 1 x internal, e. g. for<br />

software dongle<br />

- 2 x PS/2, COM1, COM2, LPT1, DVI-I<br />

- Audio: Line Out, Mic<br />

11 spare slots for expansions (all long):<br />

-7 x <strong>PC</strong>I<br />

- 1 x <strong>PC</strong>I-Express x16<br />

- 3 x <strong>PC</strong>I-Express x4<br />

Power supply: 100 ... 240 V AC, 50 ... 60 Hz


■ Design (continued)<br />

Design versions<br />

Processor:<br />

- Intel Core i7-610E (2C/4T, 2.53 GHz, 4 MB cache,<br />

Turbo Boost, VT-d, iAMT, EM64T)<br />

- Intel Core i5-520E (2C/4T, 2.4 GHz, 3 MB cache,<br />

Turbo Boost, VT-d, iAMT, EM64T)<br />

- Intel Core i3-330E (2C/4T, 2.13 GHz, 3 MB cache, EM64T)<br />

Main memory expansion<br />

- from 1 GB up to 8 GB, DDR3 1066 SDRAM (configured as<br />

dual channel for the highest performance from 2 GB<br />

upwards)<br />

- ECC memory<br />

Memory information:<br />

In order to use a memory expansion with more than 4 GB,<br />

a 64-bit operating system is required. In configurations with<br />

at least 4 GB, the visible memory can be reduced to about<br />

3.5 GB or less (with 32-bit operating systems) and in<br />

configurations with 8 GB, the visible memory can be<br />

reduced to about 7.5 GB or less.<br />

Fieldbus onboard:<br />

- PROFIBUS/MPI, CP 5611-compatible or PROFINET,<br />

3 x RJ45, CP 16116-compatible<br />

Bus module with only 8 free slots<br />

(7 x <strong>PC</strong>I, 1 x <strong>PC</strong>I-Express x16)<br />

Graphic expansion:<br />

- <strong>PC</strong>I-Express graphic card x16, (dual head with display port:<br />

2 x VGA or 2 x DVI-D via adapter), 256 MB, up to<br />

2048 x 1536 pixels, 75 Hz, 32-bit colors<br />

- Adapter cable (DVI-I to VGA) for the onboard graphic<br />

interface (1 x VGA) for connecting an analog monitor<br />

SATA 3.5" hard disks with NCQ technology or SATA 2.5"<br />

solid-state drive:<br />

- Mounted internally on the permanent hard disk support:<br />

- 1x 250 GB HDD<br />

- 1x 32 GB SSD (SLC)<br />

- Mounted internally in vibration/shock-absorbing hard-disk<br />

support or at the front in a swap frame (hot-swap in RAID1/5<br />

configuration):<br />

- 1 x 250 GB<br />

- 1 x or 2 x 500 GB<br />

- RAID1, 500 GB (2 x 500 GB, mirror disks), RAID controller<br />

onboard<br />

- RAID5, 1 TB (3 x 500 GB, striping with parity),<br />

RAID controller onboard<br />

- 1x 32 GB SSD (SLC) at front in swap frame<br />

Optical drives: DVD-ROM or DVD±/-R/RW<br />

Power supply:<br />

- 100 to 240 V AC, 50 to 60 Hz redundant<br />

- Country-specific power cable<br />

Preinstalled and activated operating systems:<br />

- Windows XP Professional multi language, 32 bit<br />

- Windows 7 Ultimate multi language, 32 bit<br />

- Windows Server 2008 Standard Edition incl. 5 Client multi<br />

language, 32 bit<br />

SIMATIC I<strong>PC</strong> DiagMonitor 1)<br />

SIMATIC <strong>PC</strong>/PG Image Creator 1)<br />

1) Further information can be found under "Expansion components".<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

Front view of SIMATIC Rack I<strong>PC</strong>847C, with open front door<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>847C<br />

Rear of SIMATIC I<strong>PC</strong>847C with redundant power supply (optional)<br />

A Tower Kit can be ordered as an accessory for converting the<br />

computer into an industrial tower <strong>PC</strong>.<br />

See "Ordering data for accessories".<br />

5/39<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>847C<br />

■ Function<br />

Multi Core processor technology<br />

Thanks to the use of two processor cores with hyper-threading,<br />

the Core i processors are ideally suited to multi-thread application<br />

programs and multitasking. Several demanding applications<br />

– such as visualization applications with demanding<br />

graphics or programs executing extensive calculations – can be<br />

executed at the same time to enhance the response time of the<br />

system. Thanks to energy-optimized Multi Core technology and<br />

outstanding energy-saving properties, the Intel Core i<br />

processors operate without any loss of performance even at<br />

increased temperatures up to 50 °C in demanding applications.<br />

The SIMATIC I<strong>PC</strong>847C is preconfigured for Multi Core<br />

technology with Intel Core i processors and Microsoft operating<br />

systems, and offers higher performance and better multitasking<br />

in the industrial environment.<br />

Multi-display technology<br />

The multi-display architecture with its modern functions for<br />

desktop and application management supports working with<br />

several screens and therefore considerably enhances productivity.<br />

The SIMATIC I<strong>PC</strong>847C with an optional dual-head graphic<br />

card (<strong>PC</strong>I Express x16) is optimized for industrial multi-display<br />

environments.<br />

The following screen modes are supported: Native DualView,<br />

Span or Big Desktop, Clone.<br />

Connection options: 2 x VGA or 2 x DVI-D<br />

Monitoring functions<br />

Integrated monitoring functions: temperature inside enclosure,<br />

fan speed (CPU, power supply and front fan), program<br />

execution (watchdog)<br />

Expanded diagnostics/messages via Ethernet, e-mail, text<br />

message and for direct transfer to SIMATIC software via O<strong>PC</strong><br />

(optionally via SIMATIC I<strong>PC</strong> DiagMonitor):<br />

Runtime meter<br />

Hard disk status, also for RAID configuration<br />

System status (Heart Beat)<br />

Automatic logging of all alarms by means of a log file<br />

Capability for central monitoring of networked SIMATIC I<strong>PC</strong><br />

AMT functionality (Intel Active Management Technology)<br />

This feature allows remote access to the I<strong>PC</strong> for diagnostics and<br />

troubleshooting (service work) even with the operating system<br />

shut down:<br />

Controlled startup/shutdown of the I<strong>PC</strong><br />

Access to BIOS settings and BIOS update<br />

Measures by means of remote access in the event of a fault,<br />

e. g. reboot<br />

Software updates from integrated ISO image<br />

RAID controller onboard<br />

RAID1 (mirroring) for automatic data mirroring on two SATA hard<br />

disks, or RAID5 (striping with parity) for optimized utilization of<br />

capacity with high degree of fault tolerance on three SATA hard<br />

disks.<br />

5/40<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Integration<br />

Integrated interfaces.<br />

Ethernet<br />

The two integrated Gigabit Ethernet interfaces (10/100/<br />

1000 Mbit/s) can be used for IT communication and for data<br />

exchange with programmable controllers such as SIMATIC S7<br />

(with the "SOFTNET S7" software package).<br />

PROFIBUS<br />

The optional floating PROFIBUS interface (12 Mbit/s) can be<br />

used to connect distributed field devices or to interface to the<br />

SIMATIC S7 (with the "SOFTNET for PROFIBUS" software<br />

packages).<br />

PROFINET<br />

The optional PROFINET interface can be used for connecting<br />

distributed field devices or for controlling drives.<br />

Further interfaces<br />

For connecting additional I/O devices, 8 or 11 free slots are<br />

available for <strong>PC</strong> modules as well as seven USB 2.0 (Universal<br />

Serial Bus), two serial interfaces, and one parallel interface.


■ Technical specifications<br />

SIMATIC I<strong>PC</strong>847C<br />

General features<br />

Design 19" rack, 4 HU, externally painted<br />

Processor Intel Core i7-610E<br />

(2C/4T, 2.53 GHz, 4 MB cache,<br />

Turbo Boost, VT-d, iAMT, EM64T)<br />

Intel Core i5-520E<br />

(2C/4T, 2.4 GHz, 3 MB cache,<br />

Turbo Boost, VT-d, iAMT, EM64T)<br />

Intel Core i3-330E<br />

(2C/4T, 2.13 GHz, 3 MB cache,<br />

EM64T)<br />

Chipset Intel QM57<br />

Main memory from 1 GB DDR3 1066 SDRAM<br />

Dual channel support<br />

2 DIMM base<br />

Expandable up to 8 GB 1)<br />

Spare slots for expansions (all 7 x <strong>PC</strong>I<br />

long)<br />

1 x <strong>PC</strong>I-Express x16<br />

3 x <strong>PC</strong>I-Express x4<br />

or<br />

7 x <strong>PC</strong>I<br />

1 x <strong>PC</strong>I-Express x16<br />

Graphics Onboard Intel GMA HD graphics<br />

controller integrated into processor;<br />

dynamic video memory; up to<br />

2048 x 1536 pixels with 75 Hz<br />

refresh rate and 16-bit colors<br />

<strong>PC</strong>I-Express graphic card<br />

(Dual Head: 2 x VGA or 2 x DVI-D<br />

via display port adapter) in the<br />

<strong>PC</strong>Ie x16 slot; 256 MB; up to 2048 x<br />

1536 pixels with 75 Hz refresh rate<br />

and 32-bit colors (optional)<br />

Operating system without<br />

Preinstalled and activated / supplied<br />

on restore DVD<br />

Windows XP Professional MUI,<br />

32-bit<br />

Windows 7 Ultimate MUI, 32-bit<br />

Windows Server 2008 incl. 5 Client<br />

MUI, 32-bit<br />

MUI: Multilanguage User Interface;<br />

5 languages (English, French,<br />

German, Italian, Spanish)<br />

Project-specific on request<br />

Linux 1)<br />

Other<br />

Power supply 100 ... 240 V AC, 50 ... 60 Hz<br />

with bridging of temporary power<br />

failures according to NAMUR: max.<br />

20 ms at 0.85% rated voltage<br />

Redundant 100 ... 240 V AC,<br />

50 ... 60 Hz<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>847C<br />

Drives<br />

SATA 3.5" hard disk or<br />

Installation in internal drive support<br />

SATA 2.25" solid-state drive 250GB<br />

32 GB SATA solid-state drive (SLC)<br />

Can be installed in internal shock and<br />

vibration-damped drive support<br />

(optional)<br />

250GB<br />

500GB<br />

2x 500GB<br />

500 GB RAID1 2) , 2 x 500 GB<br />

(mirror disks)<br />

Installation in front drive support in<br />

swap frame<br />

250GB<br />

2x 500GB<br />

500GB RAID1 2) , 2 x 500 GB<br />

(mirror disks), "hot swap"<br />

1 TB RAID5 2) SIMATIC I<strong>PC</strong>847C<br />

, 3x 500GB<br />

(mirror disks), "hot swap"<br />

32 GB SATA solid-state drive (SLC)<br />

DVD-ROM, 5.25", SATA 16x (DVD media)<br />

48 x (CD media)<br />

DVD+/-R/RW, 5.25", SATA 16 x 16 x 12 x (DVD media)<br />

48 x 32 x 48 x (CD media)<br />

Floppy disk -<br />

Slots for drives Front:<br />

3 x 5.25" and 2 x 3.5"<br />

Internal:<br />

2 x 3.5" (in the optional, vibrationdamping<br />

drive bracket)<br />

Interfaces<br />

PROFINET 3x RJ45 (CP 1616-compatible),<br />

optional<br />

PROFIBUS/MPI 12 Mbit/s (isolated, compatible with<br />

CP 5611), optional<br />

Ethernet 2 x 10/100/1000 Mbit/s (RJ45,<br />

teaming-capable)<br />

USB 2.0 2 x front (high current)<br />

4 x rear (high current)<br />

1 x internal (high current),<br />

e. g. for USB dongle<br />

Serial 9-pin COM1 (V.24)<br />

9-pin COM2 (V2.4)<br />

Parallel LPT1<br />

VGA 1 x<br />

Keyboard PS/2<br />

Mouse PS/2<br />

Audio 1 x Line Out; 1 x Micro<br />

5/41<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>847C<br />

■ Technical specifications (continued)<br />

Monitoring functions<br />

Basic functionality Message locally via DiagBase<br />

software<br />

Temperature Overshoot/undershoot of permissible<br />

operating temperature range<br />

Messages can be evaluated by<br />

the application program<br />

Fan Speed monitoring<br />

2 x enclosure fans<br />

1 x fan power supply<br />

Watchdog Monitoring of program execution<br />

Monitoring time can be parameterized<br />

in software<br />

Restart can be parameterized in<br />

the event of a fault<br />

Messages can be evaluated by<br />

the application program<br />

Monitoring functions via the<br />

network<br />

5/42<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>847C<br />

SIMATIC <strong>PC</strong> DiagMonitor (optional)<br />

Remote monitoring capability for:<br />

Watchdog<br />

Temperature<br />

Fan speed<br />

Hard disk monitoring (SMART)<br />

System/Ethernet monitoring<br />

(Heart Beat)<br />

Communication:<br />

Ethernet interface (SNMP protocol)<br />

O<strong>PC</strong> for integration in SIMATIC<br />

software<br />

Configuration of client/server architectures<br />

Layout of log files<br />

Front LEDs POWER (internal power supply unit,<br />

<strong>PC</strong> switched on)<br />

HARDDISK (access to hard disk)<br />

ETHERNET1<br />

(Ethernet status, "Heart Beat")<br />

ETHERNET2<br />

(Ethernet status, "Heart Beat")<br />

PN / MPI/DP<br />

(PROFINET/PROFIBUS status)<br />

WATCHDOG (ready/fault indication)<br />

TEMP (temperature status)<br />

FAN (fan speed monitoring)<br />

HDD1 ALARM (hard disk alarm in<br />

conjunction with RAID and<br />

monitoring software)<br />

HDD2 ALARM (hard disk alarm in<br />

conjunction with RAID and<br />

monitoring software)<br />

HDD3 ALARM (hard disk alarm in<br />

conjunction with RAID and<br />

monitoring software)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Ambient conditions<br />

Degree of protection IP41 at the front, IP20 at the rear acc.<br />

to EN 60529<br />

Dust protection With front door closed: G2 EN 779,<br />

99% of particles > 0.5 mm are held<br />

back<br />

Protection class Protection class I according to<br />

IEC 61140<br />

Vibration load during operation EN 60068-2-6, 10 cycles<br />

Internal mounting of the hard disk<br />

drives in optional, internal drive<br />

supports:<br />

10 ... 58 Hz: 0.0375 mm;<br />

58 ... 500 Hz: 5 m/s2 (ca. 0.5 g)<br />

Permanently installed internal hard<br />

disk drives:<br />

10 ... 58 Hz: 0.019 mm;<br />

58 ... 500 Hz: 3 m/s2 (ca. 0.3 g)<br />

Note:<br />

Limitations when DVD+/-RW and<br />

HDD are operated in a swap frame<br />

Shock load during operation EN 60068-2-27, IEC 60068-2-29<br />

Internal mounting of the hard disk<br />

drives in optional, internal drive<br />

supports:<br />

Half-sine: 50 m/s2 , 30 ms (ca. 5 g),<br />

100 shocks per axis<br />

Permanently installed internal hard<br />

disk drives:<br />

30m/s2 SIMATIC I<strong>PC</strong>847C<br />

, 30 ms (ca. 3 g)<br />

Note:<br />

Limitations when DVD+/-RW and<br />

HDD are operated in a swap frame<br />

Electromagnetic<br />

compatibility (EMC)<br />

Radiated interference (AC) EN 61000-6-3 FCC Class A<br />

EN 61000-3-2 Class D and<br />

EN 61000-3-3<br />

Immunity to conducted inter- ± 2 kV (IEC 61000-4-4, burst)<br />

ference on the supply lines ± 1 kV (IEC 61000-4-5, symm.<br />

surge)<br />

± 2 kV (IEC 61000-4-5, asymm.<br />

surge)<br />

Immunity to interference on ± 1 kV (IEC 61000-4-4, burst, length<br />

signal lines<br />

< 30 m)<br />

± 2 kV (IEC 61000-4-4, symm.<br />

surge, length > 30 m)<br />

± 2 kV (IEC 61000-4-5, asymm.<br />

surge, length > 30 m)<br />

Immunity to static discharge ± 6 kV, contact discharge<br />

(IEC 61000-4-2)<br />

± 8 kV, air discharge<br />

(IEC 61000-4-2)


■ Technical specifications (continued)<br />

Immunity to high radio<br />

frequency interference<br />

SIMATIC I<strong>PC</strong>847C<br />

1 V/m <strong>80</strong>% AM; 2-2.7 GHz<br />

(IEC 61000-4-3)<br />

10 V/m <strong>80</strong>% AM; <strong>80</strong> MHz to 1 GHz<br />

and 1.4 GHz and 2 GHz<br />

(IEC 61000-4-3);<br />

10 V, 10 kHz to <strong>80</strong> MHz<br />

(IEC 61000-4-6)<br />

Immunity to magnetic fields 100 A/m, 50/60 Hz (IEC 61000-4-8)<br />

Ambient temperature during 5 ... 50 °C<br />

operation<br />

Note:<br />

Limitations when DVD-ROM and<br />

DVD+/-RW operated in a swap frame<br />

Relative humidity during 5 ... <strong>80</strong>% at 25 °C (no condensation)<br />

operation<br />

1) Memory information: In order to use a memory expansion with more<br />

than 4 GB, a 64-bit operating system is required. In configurations with<br />

at least 4 GB, the visible memory can be reduced to about 3.5 GB or<br />

less (with 32-bit operating systems) and in configurations with 8 GB,<br />

the visible memory can be reduced to about 7.5 GB or less.<br />

2) Suitable for specific LINUX versions in accordance with the specifications<br />

of the <strong>Siemens</strong> manufacturer's declaration "Suited for LINUX",<br />

see www.siemens.com/simatic-pc/suited-for-linux<br />

(LINUX is a trademark of Linus Torvald).<br />

3) SATA RAID controller on board in Intel chipset<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Approvals<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>847C<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>847C<br />

Safety regulations IEC 60950-1 Second Edition,<br />

EN 60950-1:2006,<br />

UL 60950-1 Second Edition<br />

CSA C22.2 No 60950-1-07 Second<br />

Edition<br />

Approvals cULus 60950-1 Second Edition<br />

CE mark Emitted interference:<br />

EN 61000-6-3:2007<br />

Noise immunity:<br />

EN 61000-6-2:2005<br />

Dimensions and weights<br />

Mounting dimensions<br />

430x177x448<br />

(W x H x D, in mm)<br />

Weight Minimum 16 kg, maximum 23 kg<br />

Note regarding SIMATIC <strong>PC</strong> operating system licenses<br />

The accompanying operating system license is only valid for<br />

installation on the supplied SIMATIC <strong>PC</strong>. Installation can only be<br />

performed on these SIMATIC systems in accordance with<br />

Microsoft OEM licensing regulations.<br />

5/43<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>847C<br />

■ Ordering data Order No. Order No.<br />

Configuration 1)<br />

Configuration 1)<br />

1<br />

SIMATIC I<strong>PC</strong>847C<br />

Interfaces: 2 x 10/100/1000 Mbit/s<br />

Ethernet (RJ45); 1 x graphic<br />

(DVI-I); 2 x COM; 1 x LPT;<br />

2 x PS/2; 4 x USB 2.0 at rear, 2 x<br />

USB 2.0 at front; 1 x USB 2.0<br />

internal; audio; temperature and<br />

fan monitoring, watchdog; card<br />

retainer<br />

Processor, motherboard:<br />

D 6AG4 114 - 11 7 7 7 7 - 7 7 7 7<br />

Core i3-330E (2C/4T, 2.13 GHz,<br />

3 MB cache), motherboard<br />

without fieldbus<br />

G<br />

Core i3-330E (2C/4T, 2.13 GHz,<br />

3 MB cache), motherboard with<br />

PROFIBUS/MPI<br />

H<br />

Core i3-330E (2C/4T; 2.13 GHz,<br />

3 MB cache), motherboard with<br />

PROFINET (3 x RJ45,<br />

CP 1616-compatible) 2)<br />

J<br />

Core i5-520E (2C/4T, 2.4 GHz,<br />

3 MB cache, TB, iAMT, VT),<br />

motherboard without fieldbus<br />

K<br />

Core i5-520E (2C/4T, 2.4 GHz,<br />

3 MB cache, TB, iAMT, VT),<br />

motherboard with<br />

PROFIBUS/MPI<br />

L<br />

Core i5-520E (2C/4T; 2.4 GHz,<br />

3 MB cache, TB, iAMT, VT),<br />

motherboard with<br />

PROFINET (3 x RJ45,<br />

CP 1616-compatible) 2)<br />

M<br />

Core i7-610E (2C/4T, 2.53 GHz,<br />

4 MB cache, TB, iAMT, VT),<br />

motherboard without field bus<br />

N<br />

Core i7-610E (2C/4T, 2.53 GHz,<br />

4 MB cache, TB, iAMT, VT),<br />

motherboard with<br />

PROFIBUS/MPI<br />

P<br />

Core i7-610E (2C/4T; 2.53 GHz,<br />

4 MB cache, TB, iAMT, VT),<br />

motherboard with<br />

PROFINET (3 x RJ45,<br />

CP 1616-compatible) 2)<br />

R<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

1) For an up-to-date overview, see the SIMATIC <strong>PC</strong> online configurator<br />

at: www.siemens.com/ipc-configurator<br />

2) Not in combination with Windows 7 and Windows Server 2008<br />

5/44<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>847C<br />

(continued)<br />

Hard disks:<br />

D 6AG4 114 - 1 7 777 - 7 7 7 7<br />

250 GB HDD SATA; 0.5 g<br />

vibration, 5 g shock, internal<br />

A<br />

500 GB HDD SATA; 0.5 g<br />

vibration, 5 g shock, internal<br />

B<br />

2 x 500 GB HDD SATA; 0.5 g<br />

vibration, 5 g shock, internal<br />

C<br />

RAID1 500 GB (2 x 500 GB HDD<br />

SATA, mirror disks); 0.5 g<br />

vibration, 5 g shock, internal<br />

D<br />

250 GB HDD SATA; 0.3 g<br />

vibration, 3 g shock, internal<br />

G<br />

250 GB HDD SATA in swap<br />

frame; front<br />

H<br />

500 GB HDD SATA in swap<br />

frame; front<br />

K<br />

2 x 500 GB HDD SATA in swap<br />

frame; front<br />

M<br />

RAID1 500 GB (2 x 500 GB HDD<br />

SATA) in swap frame, for hot<br />

swapping; front<br />

P<br />

RAID5 1 TB (3 x 500 GB HDD<br />

SATA) in swap frame, for hot<br />

swapping; front<br />

R<br />

32 GB SSD (SLC) SATA, internal S<br />

32 GB SSD (SLC) SATA in swap<br />

frame; front<br />

Memory expansion:<br />

T<br />

1 GB DDR3 SDRAM (1 x 1 GB),<br />

single channel<br />

0<br />

2 GB DDR3 SDRAM (1 x 2 GB),<br />

single channel<br />

1<br />

4 GB DDR3 SDRAM (2 x 2 GB),<br />

dual channel<br />

2<br />

6 GB DDR3 SDRAM (1 x 2 GB,<br />

1 x 4 GB), dual channel<br />

3<br />

8 GB DDR3 SDRAM (2 x 4 GB),<br />

dual channel<br />

4<br />

2 GB DDR3 SDRAM (2 x 1 GB),<br />

dual channel<br />

5<br />

4 GB DDR3 SDRAM (2 x 2 GB),<br />

dual channel<br />

6<br />

8 GB DDR3 SDRAM (2 x 4 GB),<br />

dual channel<br />

7


<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

■ Ordering data Order No. Order No.<br />

Configuration 1)<br />

SIMATIC I<strong>PC</strong>847C<br />

(continued)<br />

Swap media:<br />

D 6AG4 114 - 1 7 7 7 7 - 7 7 7 7<br />

DVD-ROM 1<br />

DVD+/-RW 2<br />

Without swap medium<br />

Bus module / hardware<br />

expansion<br />

8<br />

Bus module, 8 slots:<br />

7 x <strong>PC</strong>I, 1 x <strong>PC</strong>Ie x16; without<br />

hardware expansions<br />

0<br />

Bus module, 8 slots:<br />

7 x <strong>PC</strong>I; 1x <strong>PC</strong>Ie x16; DVI-VGA<br />

adapter (1 x VGA) for onboard<br />

graphics<br />

1<br />

Bus module, 8 slots:<br />

7x <strong>PC</strong>I; 1x <strong>PC</strong>Ie x16 assigned;<br />

+ graphic card <strong>PC</strong>Ie x16, 2 x DP<br />

(2 x DVI-D via 2 x DP-DVI<br />

adapters)<br />

2<br />

Bus module, 8 slots:<br />

7x <strong>PC</strong>I; 1x <strong>PC</strong>Ie x16 assigned;<br />

+ graphic card <strong>PC</strong>Ie x16, 2 x DP<br />

(2 x VGA via 2 x DP-VGA<br />

adapters)<br />

3<br />

Bus module, 11 slots:<br />

7x<strong>PC</strong>I, 1x<strong>PC</strong>Ie x16,<br />

3 x <strong>PC</strong>Ie x4; without hardware<br />

expansions<br />

4<br />

Bus module, 11 slots:<br />

7 x <strong>PC</strong>I, 1x <strong>PC</strong>Ie x16,<br />

3 x <strong>PC</strong>Ie x4; + DVI-VGA adapter<br />

(VGA) for onboard graphics<br />

5<br />

Bus module, 11 slots:<br />

7 x <strong>PC</strong>I; 1x <strong>PC</strong>Ie x16 assigned,<br />

3 x <strong>PC</strong>Ie x4; + graphic card<br />

<strong>PC</strong>Ie x16, 2 x DP (2 x DVI-D via<br />

2 x DP-DVI adapters)<br />

6<br />

Bus module, 11 slots:<br />

7x <strong>PC</strong>I; 1x <strong>PC</strong>Ie x16 assigned;<br />

3x <strong>PC</strong>Ie x4; + graphic card<br />

<strong>PC</strong>Ie x16, 2 x DP (2 x VGA via<br />

2 x DP-VGA adapters)<br />

7<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

1) For an up-to-date overview, see the SIMATIC <strong>PC</strong> online configurator<br />

at: www.siemens.com/ipc-configurator<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Configuration 1)<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>847C<br />

SIMATIC I<strong>PC</strong>647C<br />

(continued)<br />

Operating system (preinstalled<br />

and activated)<br />

D 6AG4 114 - 1 7 7 7 7 - 7 777<br />

Windows XP Professional, MUI<br />

(Eng, Ger, Fr, It, Sp), SP3, 32 bit<br />

B<br />

Windows 7 Ultimate, MUI (Eng,<br />

Ger, Fr, It, Sp), 32 bit<br />

E<br />

Windows Server 2008 Standard<br />

Edition incl. 5 clients, MUI (Eng,<br />

Fr, Ger, It, Sp), SP2, 32 bit<br />

P<br />

Without operating system<br />

Software expansion<br />

X<br />

SIMATIC I<strong>PC</strong> DiagMonitor 4.2<br />

included<br />

A<br />

SIMATIC I<strong>PC</strong> Image Creator<br />

software 3.1 included<br />

B<br />

SIMATIC I<strong>PC</strong> DiagMonitor 4.2 &<br />

Image Creator software 3.1<br />

included<br />

C<br />

Without software<br />

Power supply,<br />

country-specific cable<br />

X<br />

100/240 V AC industrial power<br />

supply with Namur; power cable<br />

for Europe<br />

0<br />

100/240 V AC industrial power<br />

supply with Namur; power cable<br />

for United Kingdom<br />

100/240 V AC industrial power<br />

supply with Namur; power cable<br />

for Switzerland<br />

100/240 V AC industrial power<br />

supply with Namur; power cable<br />

for USA<br />

100/240 V AC industrial power<br />

supply with Namur; power cable<br />

for Italy<br />

100/240 V AC industrial power<br />

supply with Namur; power cable<br />

for China<br />

100/240 V AC industrial<br />

redundant power supply unit<br />

with Namur; without power cable<br />

5/45<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>847C<br />

■ Ordering data Order No. Order No.<br />

Accessories<br />

Tower Kit 6ES7 648-1AA00-0XD0<br />

Memory expansion<br />

for converting the computer into<br />

1 GB DDR3 1066 SDRAM, A 6ES7 648-2AJ40-0KA0<br />

an industrial tower <strong>PC</strong><br />

DIMM<br />

2 GB DDR3 1066 SDRAM,<br />

DIMM<br />

4 GB DDR3 1066 SDRAM,<br />

A<br />

A<br />

6ES7 648-2AJ50-0KA0<br />

6ES7 648-2AJ60-0KA0<br />

Retainer<br />

for pin assignment of the internal<br />

USB port<br />

6ES7 648-1AA00-0XK0<br />

DIMM<br />

SIMATIC <strong>PC</strong> keyboard<br />

1 GB DDR3 1066 SDRAM,<br />

DIMM, ECC<br />

2 GB DDR3 1066 SDRAM,<br />

DIMM, ECC<br />

A<br />

A<br />

6ES7 648-2AJ40-1KA0<br />

6ES7 648-2AJ50-1KA0<br />

German/international,<br />

USB port<br />

incl. 4-way USB hub A<br />

6ES7 648-0CB00-0YA0<br />

6ES7 648-0CD00-0YA0<br />

4 GB DDR3 1066 SDRAM, A<br />

DIMM, ECC<br />

Hard disk slide-in unit for swap<br />

frame<br />

6ES7 648-2AJ60-1KA0<br />

6ES7 648-0EG00-1BA0<br />

SIMATIC <strong>PC</strong> mouse A<br />

(optical, 3-button) for<br />

programming device and <strong>PC</strong> with<br />

adapter<br />

6ES7 790-0AA01-0XA0<br />

SIMATIC <strong>PC</strong> accessories, slide-in<br />

unit for low-profile HDD swap<br />

frame, for 3.5" hard disk, serial<br />

ATA (without hard disk)<br />

SIMATIC I<strong>PC</strong> USB FlashDrive A<br />

8 GB, USB 2.0, metal enclosure,<br />

bootable<br />

6ES7 648-0DC50-0AA0<br />

Filter mats<br />

For Rack <strong>PC</strong> 847B and I<strong>PC</strong>847C<br />

Packing unit 10 units<br />

Power cable, straight, 3 m long<br />

A5E010649<strong>80</strong><br />

SIMATIC I<strong>PC</strong> Service USB B<br />

FlashDrive<br />

8 GB, USB 2.0, metal enclosure,<br />

bootable, with BIOS-Manager,<br />

Image & Partition Creator pre-<br />

6AV7 672-8JD01-0AA0<br />

Austria, Belgium, Finland, 6ES7 900-0AA00-0XA0<br />

installed, incl. CD<br />

France, Germany, Netherlands,<br />

Spain, Sweden<br />

Communication products see expansion components<br />

United Kingdom<br />

Switzerland<br />

6ES7 900-0BA00-0XA0<br />

6ES7 900-0CA00-0XA0<br />

RMOS real-time operating<br />

system<br />

see expansion components<br />

USA 6ES7 900-0DA00-0XA0<br />

Italy 6ES7 900-0EA00-0XA0<br />

China 6ES7 900-0FA00-0XA0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

Note:<br />

Software Packages with SIMATIC WinCC flexible, SIMATIC<br />

WinCC and SIMATIC WinAC RTX (F) can be ordered together<br />

with the SIMATIC I<strong>PC</strong> with a price advantage.<br />

More information under "Embedded Bundles / Packages for<br />

industrial <strong>PC</strong>s".<br />

5/46<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical<br />

specifications.<br />

481.4<br />

465.1<br />

430<br />

Technical data for telescopic rails<br />

Carrying capacity per pair, min. 30 kg<br />

Extended length when fully<br />

withdrawn, min.<br />

470 mm<br />

Rail thickness, max. 9.7 mm<br />

Fixing screws M5 x 6 mm<br />

The fixing screws of the telescopic rails should not project more<br />

than 5 mm into the enclosure.<br />

The enclosure is prepared for the following telescopic rails:<br />

Co. Rittal: Type 3659.1<strong>80</strong> for 600 mm cabinet /<br />

Type RP 3659.190 for <strong>80</strong>0 mm cabinet<br />

Co. Schroff: Type <strong>2011</strong>0-072<br />

448<br />

101.6<br />

176.5<br />

492<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

■ More information<br />

Further information can be found on the Internet at:<br />

www.siemens.com/simatic-pc<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>847C<br />

5/47<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC Rack <strong>PC</strong> 647B<br />

■ Overview<br />

The SIMATIC Rack <strong>PC</strong> 647B is an extremely rugged, powerful,<br />

industrial <strong>PC</strong> for installation in 19" racks (2 HU) with a high<br />

degree of industrial functionality.<br />

It offers:<br />

extreme compactness<br />

extreme ruggedness<br />

Intel Core2 Duo technology<br />

5/48<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Extremely compact and industry-compatible for 24-hour<br />

continuous use in an industrial environment<br />

Compact enclosure design (2 HU)<br />

Suitable for installing in space-saving control cabinets only<br />

500 mm deep<br />

Maximum processor performance (in maximum configuration)<br />

without loss of power (throttling) at ambient temperatures of up<br />

to 50 °C<br />

Distinct product design with new front design and fullycoated,<br />

dirt-resistant surfaces<br />

All-metal housing with high EMC for use in industrial<br />

environment<br />

Dust protection thanks to overpressure ventilation concept<br />

with fan on the front and dust filter<br />

Special hard disk holders and card retainers for protection<br />

against vibration and shock<br />

High productivity thanks to faster data processing<br />

State-of-the-art <strong>PC</strong> technology (e. g. Intel Core2 Duo and<br />

Extended Memory 64 (EM64T) processor technology)<br />

Maximum performance (e. g. Intel 945GM Express Chipset,<br />

DDR2 memory with the support of Dual Channel technology)<br />

High data transfer rates (e. g. with Serial ATA hard disks, dual<br />

Gigabit Ethernet)<br />

Reduction in downtimes through high system availability<br />

Secure 24-hour operation (high MTBF, variable-speed fan)<br />

Efficient self-diagnostics (status display for Ethernet and<br />

PROFIBUS; alarm indication for fan, temperature, watchdog<br />

and hard disks in RAID1 configuration, SIMATIC <strong>PC</strong><br />

DiagMonitor)<br />

High degree of data security due to mirrored drive system,<br />

optionally in "hot swap" frames<br />

Service-friendly device setup (modifications, service)<br />

Cost reductions through high investment security<br />

Platform with long-term stability and embedded Intel<br />

components<br />

Availability of 3 to 5 years, guaranteed availability of spare<br />

parts for 5 years<br />

System-tested with SIMATIC components<br />

Certification for worldwide marketing (cULus)<br />

Support for legacy interfaces (PS/2, COM, LPT)<br />

Installation compatible for many device generations<br />

Worldwide service and support


■ Benefits (continued)<br />

Reduced costs due to time savings for commissioning,<br />

operation and servicing<br />

Preinstalled and activated operating system<br />

Fast restoration of the delivery status of the HDD thanks to<br />

restore DVD<br />

Low noise output thanks to controlled fan<br />

Universal implementation as an industrial workstation or<br />

server<br />

PROFIBUS or PROFINET interface and RAID1 controller<br />

onboard (optional)<br />

2 x LAN 10/100/1000 Mbit/s connections (Gbit LAN with team<br />

capability)<br />

Fast identification and replacement of the hard disk in the<br />

event of a fault (e. g. front LEDs for HDD alarm in RAID1<br />

configuration)<br />

High degree of flexibility and expansion thanks to integrated<br />

interfaces and up to 3 slots (<strong>PC</strong>I and <strong>PC</strong>I Express)<br />

■ Application<br />

The SIMATIC Rack <strong>PC</strong> 647B offers machine, plant and control<br />

cabinet builders a high-performance, highly flexible 19"-rack <strong>PC</strong><br />

platform for industrial use at the machine:<br />

Measuring, open-loop control and closed-loop control of<br />

process data and machine data<br />

Visualization of production processes<br />

Image processing and evaluation in the context of quality<br />

inspection<br />

Data acquisition and management<br />

The SIMATIC Rack <strong>PC</strong> 647B has CE marking for implementation<br />

in industrial environments as well as in domestic, commercial<br />

and office environments and can therefore be used in building<br />

automation or in public buildings as well as in industrial applications.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Design<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC Rack <strong>PC</strong> 647B<br />

Basic design<br />

All-metal 19" enclosure (2 HU) for high mechanical robustness<br />

(vibration/shock) and high EMC<br />

For mounting in a horizontal and prepared for the mounting of<br />

telescopic rails<br />

Lockable front door for authorized access (access protection)<br />

to swap media at the front, operating controls (Reset, Power),<br />

USB interface, front fan and dust filter<br />

Card retainer for <strong>PC</strong> modules for safe operation and transport<br />

(vibration, shock)<br />

Opening of the enclosure cover with only one screw and<br />

replacement of <strong>PC</strong> components (e. g. <strong>PC</strong> cards or HDD) with<br />

a single tool<br />

Front fan and dust filter can be replaced without tools<br />

Dust protection through pressurized cooling with front fan<br />

mounted in roller bearing via filter<br />

3 slots for installing drives<br />

- Front: 2 x HDD swap frames (low profile); 1 x optical drive<br />

(slimline)<br />

- Internal: 2 x 3.5" (in the optional, shock and vibrationdamped<br />

disk-drive support) as an alternative to swap<br />

frames<br />

Onboard graphics on the <strong>PC</strong>I Express bus, Intel GMA950<br />

integrated to chipset, up to 2048 x 1536 pixels, 75 Hz,<br />

16-bit colors<br />

Interfaces:<br />

- 2 x LAN 10/100/1000 Mbit/s Ethernet interface<br />

(RJ45, teaming-capable)<br />

- 4 x USB 2.0 on the rear, 2 x USB 2.0 on the front<br />

(1 of which can be used with the door closed)<br />

- 2 x PS/2, COM1, COM2, LPT1, VGA<br />

- Audio: Line Out, Mic<br />

3 spare slots for expansions (all long)<br />

Power supply: 100/240 V AC, 50/60 Hz, cable in countryspecific<br />

design<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/49<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC Rack <strong>PC</strong> 647B<br />

■ Design (continued)<br />

Design versions<br />

Processor:<br />

- Intel Core2 Duo T7400, 2.16 GHz, 667 MHz FSB, 4 MB L2<br />

cache with Extended Memory 64 (EM64) and virtualization<br />

technology (VT)<br />

- Intel Core2 Duo T5500 (1.66 GHz, 667 MHz FSB, 2 MB L2<br />

Cache with Extended Memory 64 (EM64) technology)<br />

- Intel Celeron M 440, 1.86 GHz, 533 MHz FSB, 1 MB L2<br />

cache<br />

Main memory expansion from 512 MB to 4 GB DDR2<br />

667 SDRAM (configured as dual channel for top performance<br />

from 2 GB upwards)<br />

Fieldbus onboard:<br />

- PROFIBUS/MPI, CP 5611-compatible or PROFINET,<br />

3 x RJ45, CP 1616-compatible<br />

Bus modules with 3 free slots (2 x <strong>PC</strong>I or 1 x <strong>PC</strong>I,<br />

1 x <strong>PC</strong>I Express x4; 1 x <strong>PC</strong>I Express x16)<br />

Graphic expansion:<br />

- <strong>PC</strong>I-Express graphic card x16, (Dual Head: 2 x VGA or 2 x<br />

DV-I), 128 MB, up to 2048 x 1536 pixels, 75 Hz, 32 bit colors<br />

- ADD card via <strong>PC</strong>I Express x16 slot, (1 x DVI-D) for<br />

connecting a digital monitor<br />

Drives:<br />

- Serial ATA 3.5" hard disks with NCQ technology: Mounted<br />

internally on the permanent hard disk support (1x 160 GB)<br />

- Mounted internally in vibration/shock-absorbing hard-disk<br />

support or at the front in a swap frame (hot-swap in<br />

RAID1 configuration):<br />

- 1 x 160 GB<br />

- 1x or 2x 250GB<br />

- RAID1, 2 x 250 GB (RAID controller onboard)<br />

- Optical drive DVD±/-R/RW slimline<br />

- CompactFlash drive, internal<br />

Country-specific power cable<br />

Preinstalled operating systems:<br />

- Windows XP Professional multi language<br />

- Windows Vista Ultimate multi language<br />

- Windows Server 2003 Standard Edition incl. 5 Client multi<br />

language<br />

SIMATIC <strong>PC</strong> DiagMonitor 1)<br />

SIMATIC <strong>PC</strong>/PG Image Creator 1)<br />

1) Further information can be found under "Expansion components".<br />

5/50<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Front SIMATIC Rack <strong>PC</strong> 647B, with opened front door<br />

Rear SIMATIC Rack <strong>PC</strong> 647B


■ Function<br />

Dual Core processor technology<br />

Thanks to the use of two processor cores, the Dual Core<br />

processors are ideally suited to multi-thread application<br />

programs and multitasking. Several demanding applications –<br />

such as highly graphical visualization applications or highly<br />

computational programs can execute simultaneously and<br />

therefore enhance the speed of the system response.<br />

Thanks to energy-optimized dual core technology and<br />

outstanding energy-saving properties, the Intel ® Core TM 2 Duo<br />

processors operate without any loss of performance even at<br />

increased temperatures up to 50 °C in very demanding applications.<br />

The SIMATIC Rack <strong>PC</strong> 647B is preconfigured for dual core<br />

technology with Intel ® Core TM 2 Duo processors and Microsoft<br />

Windows XP Professional or Windows Server 2003 and offers<br />

higher performance and better multitasking in the industrial<br />

environment.<br />

Multi-display technology<br />

The multi-display architecture with its modern functions for<br />

desktop and application management supports working with<br />

several screens and therefore considerably enhances productivity.<br />

The SIMATIC Rack <strong>PC</strong> 647B with its optional Dual Head<br />

graphic card (<strong>PC</strong>I Express x16) is optimized for industrial multidisplay<br />

environments. The following multidisplay modes are<br />

supported: Native DualView, Span or Big Desktop, Clone.<br />

Connection options: 2 x VGA or 2 x DVI-D<br />

Monitoring functions<br />

Integrated monitoring functions (program execution (watchdog),<br />

temperature, fan speed and hard disk status in RAID configuration)<br />

Expanded diagnostics/messages via Ethernet, e-mail, text<br />

message and for direct transfer to SIMATIC software via O<strong>PC</strong><br />

(optionally via SIMATIC I<strong>PC</strong> DiagMonitor):<br />

Runtime meter<br />

Hard disk status<br />

System status (Heart Beat)<br />

Automatic logging of all alarms by means of a log file<br />

Capability for central monitoring of networked SIMATIC <strong>PC</strong>s<br />

RAID1 (RAID controller onboard) for automatic data mirroring<br />

on two SATA hard disks<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Integration<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC Rack <strong>PC</strong> 647B<br />

Integrated interfaces:<br />

Ethernet<br />

The two integrated Gigabit Ethernet interfaces (10/100/<br />

1000 Mbit/s) can be used for IT communication and for data<br />

exchange with programmable controllers such as SIMATIC S7<br />

(with the "SOFTNET S7" software package).<br />

PROFIBUS<br />

The optional floating PROFIBUS interface (12 Mbit/s) can be<br />

used to connect distributed field devices or for coupling to the<br />

SIMATIC S7 (with the "SOFTNET for PROFIBUS" software<br />

package).<br />

PROFINET<br />

The optional PROFINET interface can be used for connecting<br />

distributed field devices or for controlling drives.<br />

Further interfaces<br />

For connecting additional I/O devices, there are 2 free slots for<br />

<strong>PC</strong>I modules, 1 free <strong>PC</strong>I Express x16 slot for optional graphic<br />

expansions and six USB 2.0 as well as two serial interfaces<br />

and one parallel interface.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/51<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC Rack <strong>PC</strong> 647B<br />

■ Technical specifications<br />

SIMATIC Rack <strong>PC</strong> 647B<br />

General features<br />

Design 19" rack, 2 HU, external coating<br />

Processor Intel Core2 Duo T7400 (2.16 GHz,<br />

667 MHz FSB, 4 MB L2 Cache with<br />

extended memory 64 (EM64)<br />

technology) and virtualization<br />

technology (VT) software<br />

Intel Core2 Duo T5500<br />

(1.66 GHz, 667 MHz FSB, 2 MB L2<br />

Cache with extended memory 64<br />

(EM64) technology)<br />

Intel Celeron M 440 (1.86 GHz,<br />

533 MHz FSB, 1 MB L2 cache)<br />

Chipset Intel 945 GM<br />

Main memory From 512 MB DDR2 667 SDRAM<br />

Dual channel support<br />

2 SODIMM base<br />

Expandable up to 4 GB<br />

Spare slots for expansions 2x <strong>PC</strong>I<br />

(all long)<br />

1 x <strong>PC</strong>I-Express x16 (PEG)<br />

or<br />

1x <strong>PC</strong>I<br />

1 x <strong>PC</strong>I-Express x4<br />

1 x <strong>PC</strong>I-Express x16 (PEG)<br />

Graphics Onboard Intel GMA950 graphics<br />

controller integrated into chipset;<br />

Dynamic Video Memory; up to<br />

2048 x 1536 pixels for 75 Hz display<br />

refresh rate and 16 bit colors<br />

<strong>PC</strong>I-Express graphic card<br />

(Dual Head: 2 x VGA or 2 x DVI-D)<br />

in the <strong>PC</strong>Ie x16 slot; 128 MB; up to<br />

2048 x 1536 pixels at 75 Hz display<br />

refresh rate and 32 bit colors<br />

(optional)<br />

Operating system without<br />

MUI: Multilanguage User Interface;<br />

5 languages (English, French,<br />

German, Italian, Spanish)<br />

Preinstalled/supplied on Restore<br />

DVD<br />

Project-specific on request 1)<br />

- Windows XP Professional MUI<br />

- Windows Vista Ultimate MUI<br />

- Windows Server 2003 incl.<br />

5 Client MUI<br />

MUI: Multilanguage User Interface;<br />

5 languages (English, French,<br />

German, Italian, Spanish)<br />

Project-specific on request 1)<br />

-Other<br />

Power supply 100/240 V AC, 50 to 60 Hz; with<br />

bridging of temporary supply failures<br />

according to NAMUR: Max. 20 ms at<br />

0.85% rated voltage<br />

1) Suitable for specific LINUX versions in accordance with the specifications<br />

of the <strong>Siemens</strong> manufacturer's declaration "Suited for LINUX",<br />

see www.siemens.com/simatic-pc/suited-for-linux<br />

(LINUX is a trademark of Linus Torvald).<br />

2) SATA RAID controller on board in Intel ICH7R chipset<br />

5/52<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Drives<br />

Hard disk, 3.5"<br />

Mounted in internal shock/vibration-<br />

Serial ATA with NCQ<br />

resistant disk drive support<br />

technology<br />

160 GB<br />

250GB<br />

2x 250GB<br />

RAID1 2) , 2x 250GB<br />

(mirror disks)<br />

or<br />

Mounted in front drive support in<br />

swap frame (low profile)<br />

160 GB<br />

250GB<br />

2x 250GB<br />

RAID1 2) SIMATIC Rack <strong>PC</strong> 647B<br />

, 2 x 250 GB, (mirror disks),<br />

for hot swapping<br />

DVD+/-R/RW, slimline 8 x 8 x 6 x (DVD media)<br />

24 x 24 x 24 x (CD media)<br />

Slots for drives Front:<br />

2 x low profile swap frames<br />

(for 3.5" HDD)<br />

1 x 12.7 mm slimline (for ODD)<br />

Internal:<br />

2 x 3.5" as an alternative to swap<br />

frames (in the optional, shock<br />

and vibration-damped disk-drive<br />

support)<br />

1 x CompactFlash drive, optional<br />

Interfaces<br />

PROFINET 3 x RJ45 (CP 1616-compatible),<br />

optional<br />

PROFIBUS/MPI 12 Mbit/s (isolated, compatible with<br />

CP 5611), optional<br />

Ethernet 2 x 10/100/1000 Mbit/s (RJ45,<br />

team-capability)<br />

USB 2 x at front (high current);<br />

high-speed USB 2.0<br />

4 x at rear (high current);<br />

high-speed USB 2.0<br />

Serial 9-pin COM1 (V.24)<br />

9-pin COM2 (V.24)<br />

Parallel LPT1<br />

VGA 1x<br />

Keyboard PS/2<br />

Mouse PS/2<br />

Audio 1 x Line Out; 1 x Micro


■ Technical specifications (continued)<br />

Monitoring functions<br />

Basic functionality Message locally via SOM<br />

(safecard on motherboard) software<br />

Temperature Overshoot/undershoot of permissible<br />

operating temperature range<br />

Messages can be evaluated by the<br />

application program<br />

Fan Speed monitoring<br />

- 2 x housing fan (front)<br />

- 1 x fan power supply<br />

Watchdog Monitoring of program execution<br />

Monitoring time can be parameterized<br />

in software<br />

Restart can be parameterized in<br />

the event of a fault<br />

Messages can be evaluated by<br />

the application program<br />

Monitoring functions via the<br />

network<br />

SIMATIC Rack <strong>PC</strong> 647B<br />

SIMATIC <strong>PC</strong> DiagMonitor<br />

(optional)<br />

Version 3.2 and higher<br />

Remote monitoring capability for:<br />

Watchdog<br />

Temperature<br />

Fan speed<br />

Hard disk monitoring (SMART)<br />

System/Ethernet monitoring<br />

(Heart Beat)<br />

Communication:<br />

Ethernet interface (SNMP protocol)<br />

O<strong>PC</strong> for integration in SIMATIC<br />

software<br />

Configuration of client/server<br />

architectures<br />

Layout of log files<br />

Front LEDs POWER (internal power supply unit,<br />

<strong>PC</strong> switched on)<br />

HARDDISK (access to hard disk)<br />

ETHERNET1 (Ethernet status,<br />

"Heart Beat")<br />

ETHERNET2 (Ethernet status,<br />

"Heart Beat")<br />

PROFIBUS/MPI (PROFIBUS status)<br />

SF PROFINET (PROFINET status)<br />

WATCHDOG (ready/fault indication)<br />

TEMP (temperature status)<br />

FAN (fan speed monitoring)<br />

HDD1 ALARM (hard disk alarm in<br />

conjunction with RAID1 and<br />

monitoring software)<br />

HDD2 ALARM (hard disk alarm in<br />

conjunction with RAID1 and<br />

monitoring software)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC Rack <strong>PC</strong> 647B<br />

Ambient conditions<br />

Degree of protection IP41 at the front, IP20 at the rear acc.<br />

to EN 60529<br />

Dust protection With front door closed: G2 EN 779,<br />

99% of particles > 0.5 mm are held<br />

back<br />

Protection class Protection class I according to<br />

IEC 61140<br />

Vibration load during operation EN 60068-2-6, 10 cycles<br />

Internal mounting of the hard disk<br />

drives in optional, internal drive<br />

supports:<br />

10 ... 58 Hz: 0.0375 mm;<br />

58 ... 500 Hz: 5 m/s2 (ca. 0.5 g)<br />

Note:<br />

Limitations when DVD+/-RW and<br />

HDD are operated in a swap frame<br />

Shock load during operation EN 60068-2-27, IEC 60068-2-29<br />

Internal mounting of the hard disk<br />

drives in optional, internal drive<br />

supports:<br />

Half-sine: 50 m/s2 SIMATIC Rack <strong>PC</strong> 647B<br />

, 30 ms (ca. 5 g),<br />

100 shocks per axis<br />

Note:<br />

Limitations when DVD+/-RW and<br />

HDD are operated in a swap frame<br />

Electromagnetic compatibility<br />

(EMC)<br />

Radiated interference (AC) EN 55022 Class B; FCC Class A<br />

Immunity to conducted inter- ± 2 kV (IEC 61000-4-4, burst)<br />

ference on the supply lines ± 1 kV (IEC 61000-4-5, symm. surge)<br />

± 2 kV (IEC 61000-4-5, asymm.<br />

surge)<br />

Immunity to interference on ± 1 kV (IEC 61000-4-4, burst, length<br />

signal lines<br />

< 3 m)<br />

± 2 kV (IEC 61000-4-4, symm. surge,<br />

length > 3 m)<br />

± 2 kV (IEC 61000-4-5, asymm.<br />

surge, length > 30 m)<br />

Immunity to static discharge ± 6 kV, contact discharge<br />

(IEC 61000-4-2)<br />

± 8 kV, air discharge (IEC 61000-4-2)<br />

Immunity to high radio 1 V/m <strong>80</strong>% AM 1 kHz; 2 ... 2.7 GHz<br />

frequency interference (IEC 61000-4-3)<br />

10 V/m <strong>80</strong>% AM 1 kHz;<br />

<strong>80</strong>MHz...1GHz and<br />

1.4 GHz ... 2 GHz (IEC 61000-4-3);<br />

10 V, 10 kHz to <strong>80</strong> MHz<br />

(IEC 61000-4-6)<br />

Immunity to magnetic fields 100 A/m, 50/60 Hz (IEC 61000-4-8)<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/53<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC Rack <strong>PC</strong> 647B<br />

■ Technical specifications (continued)<br />

SIMATIC Rack <strong>PC</strong> 647B<br />

Ambient temperature during 5 ... 50 °C<br />

operation<br />

Note:<br />

Limitations when DVD+/-RW and<br />

HDD are operated in a swap frame<br />

Relative humidity during 5 ... 85% at 30 °C (no condensation)<br />

operation<br />

Approvals<br />

Safety regulations IEC 60950-1, EN 60950-1, UL 60950,<br />

CSA C22.2 No 60950<br />

Approvals cULus 60950<br />

CE mark Use in industry:<br />

Noise immunity: EN 61000-6-2:2005<br />

Use in domestic environments:<br />

Emitted interference:<br />

EN 61000-6-3:2007<br />

Dimensions and weights<br />

Mounting dimensions<br />

430x88x445<br />

(W x H x D, in mm)<br />

Weight Minimum 16 kg, maximum 23 kg<br />

5/54<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Note regarding SIMATIC <strong>PC</strong> operating system licenses<br />

The accompanying operating system license is only valid for<br />

installation on the supplied SIMATIC <strong>PC</strong>. Installation can only be<br />

performed on these SIMATIC systems in accordance with<br />

Microsoft OEM licensing regulations.


<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

■ Ordering data Order No. Order No.<br />

Configuration 3)<br />

Configuration 3)<br />

1<br />

SIMATIC Rack <strong>PC</strong> 647B<br />

Interfaces:<br />

2 x 10/100/1000 Mbit/s Ethernet<br />

(RJ45); 1 x graphic (VGA);<br />

2 x COM; 1 x LPT; 2 x PS/2;<br />

4 x USB 2.0 at rear, 2 x USB 2.0 at<br />

front; audio; drive slots: 3 (2 x lowprofile<br />

swap frame, 1 x slimline<br />

ODD externally accessible;<br />

2 x 3.5" internally accessible,<br />

alternative to swap frame),<br />

temperature and fan monitoring,<br />

watchdog, card retainer;<br />

Processor/motherboard<br />

D 6AG4 112 - 10 7 7 7 7 - 7 7 7 7<br />

Celeron M 440 (1.86 GHz,<br />

1 MB L2 cache), motherboard<br />

without fieldbus<br />

A<br />

Celeron M 440 (1.86 GHz,<br />

1 MB L2 cache), motherboard<br />

with PROFIBUS/MPI<br />

B<br />

Celeron M 440 (1.86 GHz,<br />

1 MB L2 cache), motherboard<br />

with PROFINET (3 x RJ45,<br />

CP 1616 compatible) 1)<br />

C<br />

Core2 Duo T5500 (1.66 GHz,<br />

2 MB L2 cache, EM64-T),<br />

motherboard without fieldbus<br />

G<br />

Core2 Duo T5500 (1.66 GHz,<br />

2 MB L2 cache, EM64-T),<br />

motherboard with PROFIBUS/<br />

MPI<br />

H<br />

Core2 Duo T5500 (1.66 GHz,<br />

2 MB L2 cache, EM64-T),<br />

motherboard with PROFINET<br />

(3 x RJ45,<br />

CP 1616-compatible) 1)<br />

J<br />

Core2 Duo T7400 (2.16 GHz,<br />

4 MB L2 cache, EM64-T, VT),<br />

motherboard without fieldbus<br />

K<br />

Core2 Duo T7400 (2.16 GHz,<br />

4 MB L2 cache, EM64-T, VT),<br />

motherboard with PROFIBUS/<br />

MPI<br />

L<br />

Core2 Duo T7400 (2.16 GHz,<br />

4 MB L2 cache, EM64-T, VT),<br />

motherboard with PROFINET<br />

(3 x RJ45,<br />

CP 1616-compatible) 1)<br />

M<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

1) Not in combination with Windows 2003 Server<br />

2) Not in combination with Windows Vista Ultimate<br />

3) For an up-to-date overview, see the SIMATIC <strong>PC</strong> online configurator<br />

at: www.siemens.com/ipc-configurator<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC Rack <strong>PC</strong> 647B<br />

SIMATIC Rack <strong>PC</strong> 647B<br />

(continued)<br />

Hard disks:<br />

D 6AG4 112 - 0 7 777 - 7 7 7 7<br />

160 GB HDD SATA; 0.5 g<br />

vibration, 5 g shock, internal<br />

A<br />

250 GB HDD SATA; 0.5 g<br />

vibration, 5 g shock, internal<br />

B<br />

2 x 250 GB HDD SATA; 0.5 g<br />

vibration, 5 g shock, internal<br />

C<br />

RAID1 (2 x 250 GB HDD SATA,<br />

mirror disks); 0.5 g vibration,<br />

5 g shock, internal<br />

D<br />

160 GB HDD SATA in swap<br />

frame; front<br />

H<br />

250 GB HDD SATA in swap<br />

frame; front<br />

K<br />

2 x 250 GB HDD SATA in swap<br />

frame; front<br />

M<br />

RAID1 (2 x 250 GB HDD SATA)<br />

in swap frame, for hot swapping;<br />

front<br />

Memory expansion:<br />

P<br />

512 MB DDR2 SDRAM<br />

(1 x 512 MB), single channel<br />

1<br />

1 GB DDR2 SDRAM (1 x 1 GB),<br />

single channel<br />

2<br />

2 GB DDR2 SDRAM (2 x 1 GB),<br />

dual channel<br />

3<br />

4 GB DDR2 SDRAM (2 x 2 GB),<br />

dual channel<br />

Swap media:<br />

4<br />

CompactFlash drive, internal 0<br />

DVD±RW 1<br />

without swap medium 8<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/55<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC Rack <strong>PC</strong> 647B<br />

■ Ordering data Order No. Order No.<br />

Configuration<br />

1)<br />

2)<br />

3)<br />

Not in combination with Windows 2003 Server<br />

Not in combination with Windows Vista Ultimate<br />

For an up-to-date overview, see the SIMATIC <strong>PC</strong> online configurator<br />

at: www.siemens.com/ipc-configurator<br />

Note:<br />

3)<br />

SIMATIC Rack <strong>PC</strong> 647B D<br />

(continued)<br />

Bus module / hardware expansion<br />

6AG4 112 - 0 7 7 7 7 - 7 777<br />

Bus modules 3 slots: 2 x <strong>PC</strong>I;<br />

1 x <strong>PC</strong>Ie x16; without hardware<br />

expansions<br />

Bus modules 3 slots: 2 x <strong>PC</strong>I;<br />

1 x <strong>PC</strong>Ie x16 assigned; + DVI<br />

extension adapter (DVI-D)<br />

0<br />

1<br />

Bus modules 3 slots: 2 x <strong>PC</strong>I;<br />

1 x <strong>PC</strong>Ie x16 assigned; +<br />

graphic card <strong>PC</strong>Ie x16, DH<br />

2<br />

(2 x DVI or 2 x VGA)<br />

Bus modules 3 slots: 1 x <strong>PC</strong>I,<br />

1 x <strong>PC</strong>Ie x4; 1 x <strong>PC</strong>Ie x16;<br />

3<br />

without hardware expansions<br />

Bus modules 3 slots: 1 x <strong>PC</strong>I,<br />

4<br />

1 x <strong>PC</strong>Ie x4; 1 x <strong>PC</strong>Ie x16<br />

assigned; + DVI extension<br />

adapter (DVI-D)<br />

Bus modules 3 slots: 1 x <strong>PC</strong>I,<br />

1 x <strong>PC</strong>Ie x4; 1 x <strong>PC</strong>Ie x16<br />

assigned; + graphic card <strong>PC</strong>Ie<br />

x16, DH (2 x DVI or 2 x VGA)<br />

5<br />

Operating system (preinstalled<br />

and activated)<br />

Windows XP Professional, MUI<br />

(Eng, Ger, Fr, It, Sp), SP2; SP3<br />

assigned<br />

Windows Vista Ultimate, MUI<br />

(Eng, Ger, Fr, It, Sp); SP1<br />

assigned<br />

B<br />

C<br />

Windows Server 2003 Standard<br />

Edition incl. 5 Client, MUI (Eng,<br />

M<br />

Ger, Fr, It, Sp), SP1; SP2<br />

assigned<br />

Without operating system<br />

Expansion (software)<br />

SIMATIC <strong>PC</strong> DiagMonitor 3.2<br />

X<br />

2)<br />

software enclosed<br />

A<br />

SIMATIC <strong>PC</strong> Image Creator 2.1<br />

software enclosed<br />

B<br />

SIMATIC <strong>PC</strong> DiagMonitor 3.2 2)<br />

Accessories<br />

Memory expansion<br />

512 MB DDR2 667 SDRAM,<br />

SO DIMM<br />

A 6ES7 648-2AG30-0HA0<br />

1 GB DDR2 667 SDRAM,<br />

SO DIMM<br />

2 GB DDR2 667 SDRAM,<br />

SO DIMM<br />

Power cable, straight, 3 m long<br />

A<br />

A<br />

6ES7 648-2AG40-0HA0<br />

6ES7 648-2AG50-0HA0<br />

Austria, Belgium, Finland,<br />

France, Germany, Netherlands,<br />

Spain, Sweden<br />

6ES7 900-0AA00-0XA0<br />

United Kingdom 6ES7 900-0BA00-0XA0<br />

Switzerland 6ES7 900-0CA00-0XA0<br />

USA 6ES7 900-0DA00-0XA0<br />

Italy 6ES7 900-0EA00-0XA0<br />

China 6ES7 900-0FA00-0XA0<br />

Expansion components<br />

SIMATIC <strong>PC</strong> keyboard<br />

German/international<br />

USB port 6ES7 648-0CB00-0YA0<br />

incl. 4-way USB hub A 6ES7 648-0CD00-0YA0<br />

SIMATIC <strong>PC</strong> mouse A 6ES7 790-0AA01-0XA0<br />

(optical, 3-button) for PG and <strong>PC</strong><br />

with adapter<br />

SIMATIC I<strong>PC</strong> USB FlashDrive A<br />

8 GB, USB 2.0, metal enclosure,<br />

bootable<br />

6ES7 648-0DC50-0AA0<br />

SIMATIC I<strong>PC</strong> Service USB<br />

FlashDrive<br />

B 6AV7 672-8JD01-0AA0<br />

8 GB, USB 2.0, metal enclosure,<br />

bootable, with BIOS-Manager,<br />

Image & Partition Creator preinstalled,<br />

incl. CD<br />

Communication products<br />

Power supplies and DC UPS<br />

see expansion components<br />

see expansion components<br />

RMOS real-time operating<br />

system<br />

see expansion components<br />

and Image Creator 2.1 software<br />

C A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

enclosed<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

Without software X D: Subject to export regulations: AL: N and ECCN: 5D992<br />

Power supply, with countryspecific<br />

cable:<br />

100/240 V AC industrial power<br />

supply with Namur; power cable<br />

for Europe<br />

0<br />

1<br />

100/240 V AC industrial power<br />

supply with Namur; power cable<br />

for United Kingdom<br />

100/240 V AC industrial power<br />

supply with Namur; power cable<br />

for Switzerland<br />

100/240 V AC industrial power<br />

supply with Namur; power cable<br />

for USA<br />

100/240 V AC industrial power<br />

supply with Namur; power cable<br />

for Italy<br />

100/240 V AC industrial power<br />

supply with Namur power cable<br />

for China<br />

5/56<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

2<br />

3<br />

4<br />

5<br />

Software Packages with SIMATIC WinCC flexible, SIMATIC<br />

WinCC and SIMATIC WinAC RTX (F) can be ordered together<br />

with the SIMATIC I<strong>PC</strong> with a price advantage.<br />

More information under "Embedded Bundles / Packages for<br />

industrial <strong>PC</strong>s".


■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical<br />

specifications.<br />

8.2<br />

481.4<br />

465<br />

429.9<br />

Technical specifications of the telescopic rails<br />

Carrying capacity per pair, min. 30 kg<br />

Extension length for full extension,<br />

min.<br />

470 mm<br />

Rail thickness, max. 9.7 mm<br />

Fastening screws M5 x 6 mm<br />

The fastening screws for the telescopic rails are permitted to<br />

extend 5 mm into the housing.<br />

The housing is prepared for the following telescopic rails:<br />

Co. Rittal: Type 3659.1<strong>80</strong> for 600 mm cabinet /<br />

Type RP 3659.190 for <strong>80</strong>0 mm cabinet<br />

444.6<br />

76.2<br />

5.7<br />

487.1<br />

87.6<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00453<br />

<strong>PC</strong>-based Automation<br />

Rack <strong>PC</strong><br />

SIMATIC Rack <strong>PC</strong> 647B<br />

■ More information<br />

Further information can be found on the Internet at:<br />

www.siemens.com/simatic-pc<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/57<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

Box <strong>PC</strong><br />

■ Overview<br />

SIMATIC Box <strong>PC</strong> provide mechanical engineers, plant engineers<br />

and control cabinet makers with particularly rugged industrial<br />

<strong>PC</strong> systems for use in powerful yet compact applications.<br />

The following device classes are available for various requirements:<br />

SIMATIC I<strong>PC</strong>227 (Nanobox <strong>PC</strong>) – the new Nanobox <strong>PC</strong> with<br />

maximum flexibility – absolutely maintenance-free<br />

SIMATIC I<strong>PC</strong>427 (Microbox <strong>PC</strong>) – ultra-compact and<br />

maintenance-free: The flexible embedded industrial <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>627 (Box <strong>PC</strong>) – maximum performance in the<br />

most restricted space<br />

SIMATIC I<strong>PC</strong>827 (Box <strong>PC</strong>) – maximum performance with high<br />

expandability<br />

5/58<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Shared industrial functionality:<br />

Extreme compactness<br />

Certification for global marketing<br />

System-tested with SIMATIC components<br />

High vibration/shock load during operation<br />

Wide operational temperature range<br />

Robust data storage with CompactFlash or Solid-State Drive<br />

(SSD)<br />

Integrated PROFIBUS or PROFIBUS/MPI interface (optional)<br />

Varied mounting possibilities for flexibility with installation<br />

Designed for 24-hour continuous operation<br />

Integrated parameterizable monitoring functions<br />

(temperature, fan, watchdog)<br />

High service friendliness<br />

Operating system preinstalled and activated for fast startup<br />

Motherboard developed and manufactured by <strong>Siemens</strong><br />

Availability for 3 to 5 years<br />

Repairs and spare parts service for 5 years<br />

High continuity of the components/design<br />

Installation and software compatible with predecessor model<br />

Long-term availability of <strong>PC</strong> components from the Intel<br />

embedded line<br />

SIMATIC I<strong>PC</strong>227D – for implementation of simple control,<br />

data collection or communication tasks<br />

Maximum compactness with approx. 1 liter enclosure volume<br />

with integrated industrial power supply for minimum space<br />

requirements in the control cabinet<br />

Maximum flexibility thanks to four mounting options and<br />

interfaces on one side suitable for every installation situation<br />

Optimum variety of interfaces due to a large number of<br />

integrated interfaces such as a selectable serial port (RS232/<br />

RS485/CAN) and 2 x teaming-capable Gigabit LAN<br />

Maximum industrial functionality due to closed enclosure for<br />

optimum dust protection and non-volatile retentive memory<br />

Further device options for optimum adaptation to the<br />

application with additional <strong>PC</strong>Ie slot or RS232 interfaces or<br />

digital input/output


■ Overview (continued)<br />

SIMATIC I<strong>PC</strong>427 (Microbox <strong>PC</strong>) – ultra-compact and<br />

maintenance-free: the flexible embedded industrial <strong>PC</strong><br />

Fanless operation<br />

High performance with highly compact design<br />

Optimized for embedded applications<br />

Expandable with as many as 3 <strong>PC</strong>/104-Plus or <strong>PC</strong>I-104 I/O<br />

cards<br />

Flexible installation options due to DIN rail/wall/front upright<br />

mounting, even outside a control cabinet<br />

SIMATIC I<strong>PC</strong>627 (Box <strong>PC</strong>) – maximum performance in the<br />

most restricted space<br />

Maximum system performance for complex measuring,<br />

control and visualization tasks<br />

Highly compact for space-saving installation with compact<br />

enclosure design (6 liters in volume)<br />

Flexible, space-saving installation with mounting brackets or<br />

portrait assembly kits<br />

Rugged design for direct installation in the machine<br />

RAID1 controller onboard<br />

Maximum processor performance up to ambient temperature<br />

of 55 °C<br />

High shock/vibration resistance in all possible mounting<br />

positions<br />

High system availability<br />

Battery-backed SRAM as memory for WinAC data<br />

2 x 7-segment display and 2 signal LEDs (freely<br />

programmable)<br />

SIMATIC I<strong>PC</strong>227D<br />

(Nanobox <strong>PC</strong>)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>427C<br />

(Microbox <strong>PC</strong>)<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Box <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>827 (Box <strong>PC</strong>) – maximum performance with high<br />

expandability<br />

Maximum system performance for complex measuring,<br />

control and visualization tasks<br />

High flexibility with 5 expansion slots and integrated interfaces<br />

Flexible, space-saving installation with mounting brackets or<br />

portrait assembly kits<br />

Rugged design for direct installation in the machine<br />

RAID1 controller onboard<br />

Maximum processor performance up to ambient temperature<br />

of 55 °C<br />

High shock/vibration resistance in all possible mounting<br />

positions<br />

All interfaces on one side to allow optimum installation in<br />

control cabinet<br />

2 CompactFlash drives, both accessible from the outside<br />

High system availability<br />

Battery-backed SRAM as memory for WinAC data<br />

2 x 7-segment display and 2 signal LEDs (freely<br />

programmable)<br />

SIMATIC I<strong>PC</strong>627C<br />

(Box <strong>PC</strong>)<br />

SIMATIC I<strong>PC</strong>827C<br />

(Box <strong>PC</strong>)<br />

Design<br />

Rail or wall mounting - -<br />

Wall or portrait mounting<br />

General features<br />

Also: Side mounting<br />

Processor Intel Atom E660<br />

Intel Core2 Duo 1.2 GHz, Intel Core i7-620E, 2.53 Intel Core i7-620E, 2.53<br />

1.3 GHz<br />

<strong>80</strong>0 MHz FSB, 3 MB SLC GHz, 2 cores, 4 threads, GHz, 2 cores, 4 threads,<br />

Intel Atom E620<br />

Intel Core2 Solo 1.2 GHz, 4 MB cache, TB, HT, VT-x, 4 MB cache, TB, HT,<br />

600 MHz<br />

<strong>80</strong>0 MHz FSB, 3 MB SLC VT-d<br />

VT-x, VT-d<br />

Intel Celeron M 1.2 GHz, Intel Core i3-330E, Intel Core i3-330E,<br />

<strong>80</strong>0 MHz FSB, 1 MB SLC 2.13 GHz, 2 cores, 2.13 GHz, 2 cores,<br />

4 threads,<br />

4 threads, 3 MB cache,<br />

3 MB cache, HT, VT-x HT, VT-x<br />

Intel Celeron P4505, Intel Celeron P4505,<br />

1.86 GHz, 2 cores, 2 MB 1.86 GHz, 2 cores, 2 MB<br />

cache<br />

cache<br />

Main memory 512MB, 1GB 1 GB, (2/4 GB optional) 1 GB, expandable up to 1 GB, expandable up to<br />

DDR3 SDRAM<br />

4GB,<br />

4GB,<br />

optional ECC<br />

optional ECC<br />

Static RAM 512 KB (MRAM) 2MB 2MB 2MB<br />

Free slots for expansions 1 x <strong>PC</strong>Ie with <strong>PC</strong>Ie Up to 3 x <strong>PC</strong>I-104<br />

2 x <strong>PC</strong>I or<br />

3 x <strong>PC</strong>I (290/290/240 mm),<br />

enclosure option<br />

(with expansion frame) 1 x <strong>PC</strong>I-Express x16 / 1 x 1 <strong>PC</strong>I-Express x (185 mm)<br />

<strong>PC</strong>I (175 mm / 265 mm) 1 x <strong>PC</strong>I-Express x16<br />

(240 mm)<br />

Graphics Onboard Onboard Onboard Onboard<br />

5/59<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

Box <strong>PC</strong><br />

■ Overview (continued)<br />

Operating system<br />

Without<br />

Preinstalled and activated /<br />

supplied on restore CD<br />

Available<br />

- Not available<br />

1) Suitable for specific Linux versions in accordance with the specifications<br />

of the <strong>Siemens</strong> manufacturer's declaration "Suited for Linux", see<br />

www.siemens.com/simatic-pc/suited-for-linux<br />

(Linux is a trademark of Linus Torvald).<br />

5/60<br />

SIMATIC I<strong>PC</strong>227D<br />

(Nanobox <strong>PC</strong>)<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Windows XP Embedded<br />

Standard 2009, in combination<br />

with CF card of<br />

2 GB or more, solid-state<br />

drive, or hard drive<br />

Windows XP Professional<br />

MUI (in combination with<br />

solid-state drive or hard<br />

drive<br />

Windows Embedded<br />

Standard 2009, in combination<br />

with CF card ≥<br />

2 GB, solid-state drive,<br />

or hard drive<br />

Windows XP Professional<br />

multi language; in combination<br />

with solid-state<br />

drive or hard drive<br />

Windows 7 Ultimate MUI<br />

Windows Embedded<br />

Standard 7<br />

Windows XP Professional<br />

MUI<br />

Windows Embedded<br />

Standard 2009 English on<br />

8 GB CompactFlash<br />

Windows 7 Ultimate MUI<br />

Order separately - RMOS3 V3.50 RMOS3 V3.50 RMOS3 V3.50<br />

Project-specific on request Linux 1)<br />

Other<br />

Interfaces<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>427C<br />

(Microbox <strong>PC</strong>)<br />

Linux 1)<br />

Other<br />

PROFINET onboard Via standard Ethernet 3xRJ45<br />

(CP 1616 compatible)<br />

onboard, optional<br />

PROFIBUS/MPI - 12 Mbit/s<br />

(CP 5611-compatible),<br />

optional<br />

SIMATIC I<strong>PC</strong>627C<br />

(Box <strong>PC</strong>)<br />

Linux 1)<br />

Other<br />

3xRJ45<br />

(CP 1616 compatible)<br />

onboard, optional<br />

12 Mbit/s<br />

(CP 5611-compatible)<br />

onboard, optional<br />

SIMATIC I<strong>PC</strong>827C<br />

(Box <strong>PC</strong>)<br />

Windows XP Professional<br />

MUI<br />

Windows Embedded<br />

Standard 2009 English on<br />

8 GB CompactFlash<br />

Windows 7 Ultimate MUI<br />

Linux 1)<br />

Other<br />

3xRJ45<br />

(CP 1616 compatible)<br />

onboard, optional<br />

12 Mbit/s<br />

(CP 5611-compatible)<br />

onboard, optional<br />

Ethernet 2 x 10/100/1000 Mbit/s 2 x 10/100/1000 Mbit/s 2 x 10/100/1000 Mbit/s 1 x 10/100/1000 Mbit/s<br />

USB 2.0 (high current) 4x 4x 4x 4x<br />

VGA, LVDS, DVI<br />

Drives<br />

1 x DVI-D 1 x DVI-I (DVI and VGA) 1x DVI-I 1 x DVI-I<br />

Hard disks 1 x 2.5" (optional) 1 x 2.5" (optional) 1 x 3.5"<br />

1 x 3.5"<br />

2 x 2.5"<br />

2 x 2.5"<br />

RAID1/2 x 2.5"<br />

RAID1/2x 2.5"<br />

Solid State Drive 1 x 2.5" Solid-State Drive<br />

(optional)<br />

1 x 2.5” (optional SATA) 1 x 2.5" SATA (optional) 1 x 2.5" SATA (optional)<br />

FlashDrive 1 x externally accessible 1 x externally accessible 1 x at the front, externally 1 x at the front, externally<br />

1 x internal, in place of accessible<br />

accessible<br />

HDD, SSD (optional) 1 x internal, in place of 1 x at the front, in place of<br />

HDD (optional)<br />

HDD (optional)<br />

Optical drives<br />

Ambient conditions<br />

- - DVD R/W DVD R/W<br />

Vibration/shock load during<br />

operation<br />

1 g / 15 g (with Flash drive) 1g / 5g 1 g / 5 g<br />

Ambient temperature during 0 °C … 50 °C With maximum<br />

With maximum<br />

With maximum<br />

operation<br />

configuration:<br />

configuration:<br />

configuration:<br />

0 ... 50/55 ºC<br />

5 ... 45 °C<br />

5 ... 45 °C<br />

(with flash drive)<br />

5 ... 50/55 °C<br />

5 ... 50/55 °C<br />

5 ... 40 ºC (with hard disk) (with 20/10 W load on (with 20/10 W load on<br />

<strong>PC</strong>I/<strong>PC</strong>I-Express bus) <strong>PC</strong>I/<strong>PC</strong>I-Express bus)


■ Benefits<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Box <strong>PC</strong><br />

■ More information<br />

Compact dimensions<br />

Further information can be found on the Internet at:<br />

The SIMATIC I<strong>PC</strong>227D is a particularly compact and energy- www.siemens.com/simatic-pc<br />

efficient <strong>PC</strong> in the Nano format. The heart of the Nanobox <strong>PC</strong> Information material can be ordered or downloaded from the<br />

with particularly many mounting options are high-performance Internet:<br />

Intel Atom processors of the latest generation.<br />

www.siemens.com/simatic/printmaterial<br />

The SIMATIC I<strong>PC</strong>427 (Microbox <strong>PC</strong>) is an ultra-compact and<br />

rugged device for DIN rail mounting, portrait or wall mounting,<br />

and for use in the machine: mounting depth from 47 mm.<br />

With a maximum mounting depth of 100 mm (<strong>80</strong> mm without<br />

DVD drive), the SIMATIC I<strong>PC</strong>627 (Box <strong>PC</strong>) can be used even in<br />

the smallest of spaces. In addition, space-saving portrait<br />

mounting is possible with the SIMATIC Box I<strong>PC</strong>627/I<strong>PC</strong>827.<br />

Rugged design<br />

All designs aim to achieve maximum safety in the case of<br />

vibration and shock loads. For example, a special vibrationabsorbing<br />

suspension of the hard disk ensures operational<br />

reliability, even at very high mechanical loads. A flash drive slot,<br />

which is easily accessible from outside, or the solid-state drive<br />

(SSD) in the single level cell (SLC) architecture, which is particularly<br />

suitable for industrial applications, is available for setting<br />

up low-maintenance, fault-tolerant, diskless systems. Thanks to<br />

its fan-free design and use of CompactFlash cards, the<br />

Microbox <strong>PC</strong> and the new Nanobox <strong>PC</strong> are especially suitable<br />

for maintenance-free 24-hour continuous operation.<br />

Service-friendly device design<br />

The Box <strong>PC</strong> can simply be folded out for speedy component<br />

replacement. The inside of the device is easily accessible for<br />

future expansions.<br />

Integrated interfaces<br />

On Box <strong>PC</strong>s, all interfaces are located on one side. Box <strong>PC</strong>s can<br />

be interfaced with the control/cell level via onboard Ethernet<br />

interfaces and communicate in the field via an integrated<br />

PROFIBUS interface, which is available as an option. External<br />

monitors or displays can be connected via a VGA or DVI-I<br />

interface.<br />

Flexibility<br />

Especially the SIMATIC I<strong>PC</strong>827 with its 5 free <strong>PC</strong> slots offers<br />

many expansion options. All Box <strong>PC</strong>s have CE certification for<br />

use in industrial applications and domestic/commercial applications<br />

and can therefore be used in building automation or public<br />

installations in addition to industrial applications.<br />

Continuity<br />

Thanks to motherboards developed and manufactured inhouse,<br />

the SIMATIC Box <strong>PC</strong>s offer very high continuity and<br />

security of investment. The SIMATIC Box <strong>PC</strong> models can<br />

normally be ordered for a period of three years and spare parts<br />

are obtainable for at least 5 years after active marketing is<br />

concluded.<br />

System availability<br />

SIMATIC Box <strong>PC</strong>s can be ordered in custom configurations and<br />

are supplied ready for use. The high system availability by<br />

design can be further increased by means of additional data<br />

backup options (e.g. RAID system, SIMATIC <strong>PC</strong> Image&Partition<br />

Creator) and efficient software for self-diagnosis (SIMATIC I<strong>PC</strong><br />

DiagMonitor).<br />

5/61<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>227D<br />

■ Overview<br />

SIMATIC I<strong>PC</strong>227D available for implementing simple control,<br />

data collector or communication tasks:<br />

Maximum compactness from approx. 1 liter enclosure volume<br />

with integrated industrial power supply for minimum space<br />

requirements in the control cabinet<br />

Maximum flexibility thanks four mounting options and<br />

interfaces on one side suitable for every installation situation<br />

Optimum variety of interfaces due to a large number of<br />

integrated interfaces such as a selectable serial port (RS232/<br />

RS485/CAN) and 2 x teaming-capable Gigabit LAN<br />

Maximum industrial functionality due to closed enclosure for<br />

optimum dust protection and non-volatile retentive memory<br />

Further device options for optimum adaptation to the<br />

application with additional <strong>PC</strong>Ie slot or RS232 interfaces or<br />

digital input/output<br />

5/62<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Flexible installation (rail, wall, portrait, side mounting);<br />

all mounting positions are allowed<br />

Minimum space requirements (installation space from approx.<br />

1 liter; all interfaces on one side, integrated industrial power<br />

supply)<br />

Up to 50°C ambient temperature; dust protection due to<br />

closed enclosure<br />

LED for efficient self-diagnostics (e.g. using WinAC: Run/Stop,<br />

Error, Maintenance); optimized for headless operation<br />

Device options for optimum adaptation to the application<br />

(optional)<br />

- Simple expansion by means of a <strong>PC</strong>Ie slot or<br />

- three additional RS232 interfaces or<br />

- four additional digital inputs and outputs each, 24 V DC<br />

High-performance data processing at low power consumption<br />

Intel Atom technology of the Power-Optimized family E6xx<br />

Power consumption from 8 W (low waste heat in protective<br />

enclosure/control cabinet)<br />

Wake-on-LAN for remote-controlled switching between<br />

standby and active state<br />

Support of Sleep States/SpeedStep (dynamic power<br />

adaptation depending on the required computing<br />

performance)<br />

Intel VT-x technology for virtualization<br />

High degree of industrial functionality and flexibility for<br />

implementing the embedded solution<br />

Flexible memory concepts: CompactFlash or more, Solid-<br />

State Drive, or hard drive<br />

2 Gbit Ethernet (teaming-capable); PROFINET with<br />

RT functionality (via Standard Ethernet)<br />

4 high-speed USB 2.0 ports<br />

1 RS232; alternatively as: RS485 or CAN (optional)<br />

Ready-to-run embedded bundles with WinAC RTX2010 (F)<br />

and/or WinCC RT Advanced (optional)<br />

512 KB retentive memory (MRAM), of which 128 KB can be<br />

written to within the buffer time (optional)<br />

Embedded and standard operating systems for selection:<br />

WES 2009 and Windows XP Prof.; WES 7 and Windows 7<br />

available soon<br />

Suited for Linux certificate for simple, secure implementation<br />

of proprietary Linux-based solutions available soon<br />

High system availability in order to reduce the risk of potential<br />

failures and maintenance costs<br />

Maintenance-free since there are no rotating parts (fans, HDD)<br />

Battery-free operation even if retentive memory option is<br />

selected (with time-of-day synchronization over network)<br />

Comprehensive self-diagnostics thanks to pre-installed local<br />

diagnostics software SIMATIC I<strong>PC</strong> DiagBase<br />

High investment security in order to reduce engineering costs<br />

Long-term availability: Service & Support period of<br />

8 – 10 years after market launch


■ Application<br />

The SIMATIC I<strong>PC</strong>227D is a particularly compact and energyefficient<br />

<strong>PC</strong> in the Nano format. The heart of the Nanobox <strong>PC</strong><br />

with particularly many mounting options are high-performance<br />

Intel Atom processors of the latest generation. The Nanobox <strong>PC</strong><br />

is designed for maintenance-free 24-hour continuous use as well<br />

as for high temperature, vibration, shock and EMC requirements<br />

in the following applications:<br />

Simple control, visualization and communication tasks, data<br />

collector, for example in mechanical engineering,<br />

transportation systems or power transmission.<br />

Acquisition, further processing and visualization of data<br />

All machine-level applications created in C/C++ or with<br />

WinAC/WinCC RT Advanced that require rugged, compact<br />

I<strong>PC</strong>s<br />

Additional new applications such as shipbuilding, building<br />

automation, storage & logistics<br />

The application spectrum ranges from automation computers<br />

fully integrated in TIA with WinAC, for example, to C/C++-based<br />

automation solutions and "standalone" applications for general<br />

IT applications. For software products that require Windows XP<br />

Professional, the combination of Windows XP Professional multi<br />

language is available preinstalled on the Solid-State Drive or<br />

hard disk.<br />

The SIMATIC I<strong>PC</strong>227D can be operated both in the industrial<br />

sector as well as in domestic, business and commercial environments.<br />

The SIMATIC I<strong>PC</strong>227D can be used in conjunction with<br />

WinCC RT Advanced and/or with WinAC RTX 2010/F as readyto-run<br />

bundle and is available at an attractive price.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Design<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>227D<br />

Basic design<br />

All-metal enclosure, resistant to vibrations and shocks, also<br />

with high electromagnetic compatibility<br />

Onboard graphics, DVI (digital)<br />

- DVI-D resolution: up to 1920 x 1200 pixels<br />

Optical drives can be connected externally via USB interface,<br />

not included in scope of supply<br />

Interfaces (accessible from one side):<br />

- 2 x LAN 10/100/1000 Mbit/s Ethernet interface (RJ45)<br />

- 4 x high-speed USB V2.0<br />

- 1 x COM1 (RS232)<br />

Fieldbus<br />

- PROFINET Realtime via Standard Ethernet interface<br />

- Isolated power supply: 24 V DC (20.4 to 28.8 V)<br />

Design versions<br />

Processor / main memory expansion:<br />

- Intel Atom E660 1.3 GHz, 2 GB RAM<br />

- Intel Atom E640 1.0 GHz, 1 GB RAM<br />

- Intel Atom E620 600 MHz, 512 MB RAM<br />

Retentive memory<br />

- 512 KB retentive memory (MRAM), of which 128 KB can be<br />

written to within the buffer time (optional)<br />

Hardware expansion as device versions:<br />

-COM2-4<br />

- 4 dig. inputs/outputs each, 24 V<br />

- 1 <strong>PC</strong>Ie slot (x1)<br />

Drives:<br />

- CompactFlash drive (replaceable, accessible): 2 GB, 4 GB<br />

or 8 GB<br />

- Solid-State Drive 50 GB, rugged alternative to hard disk<br />

(SLC technology)<br />

- Hard disk 250 MB Serial ATA, 2.5"<br />

Preinstalled operating systems:<br />

- Windows XP Embedded Standard 2009<br />

- Windows XP Professional multi language<br />

- Windows Embedded Standard 7 / Windows 7 available soon<br />

5/63<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>227D<br />

■ Design (continued)<br />

SIMATIC I<strong>PC</strong>227D (bottom side), basic version<br />

SIMATIC I<strong>PC</strong>227D (bottom side), COM version<br />

SIMATIC I<strong>PC</strong>227D (bottom side), IO version<br />

SIMATIC I<strong>PC</strong>227D (bottom side), <strong>PC</strong>Ie version<br />

5/64<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>227D bundles: HMI, RTX, RTX F and HMI/RTX<br />

HMI, RTX, RTX F and HMI/RTX complete turnkey solutions (the<br />

software is already preinstalled and configured) for visualization<br />

and automation in combination with WinCC RT Advanced and<br />

WinAC RTX 2010 /F<br />

Quick start in automation solutions with Embedded<br />

Automation<br />

HMI: SIMATIC WinCC RT Advanced preinstalled and ready to<br />

run<br />

RTX: SIMATIC WinAC RTX 2010 preinstalled and ready to run<br />

RTX F: SIMATIC WinAC RTX 2010 F preinstalled and ready to<br />

run<br />

HMI/RTX (F): SIMATIC WinCC RT Advanced and SIMATIC<br />

WinAC RTX 2010(F) preinstalled and ready to run<br />

PROFINET (RT) pre-configured for use in a SIMATIC<br />

environment<br />

Configuration and programming with SIMATIC WinCC<br />

Engineering System and SIMATIC <strong>ST</strong>EP 7 via Industrial<br />

Ethernet<br />

Flexibility of a <strong>PC</strong>-based automation environment<br />

Open for additional <strong>PC</strong> applications<br />

Connection option for USB devices<br />

Use of WinAC ODK with SIMATIC WinAC RTX<br />

Data retentivity for WinAC RTX without uninterruptible power<br />

supply (UPS)<br />

Expansion components<br />

SIMATIC I<strong>PC</strong> DiagMonitor<br />

<strong>PC</strong> diagnostics/alarm software for early detection and<br />

diagnostics of <strong>PC</strong> problems<br />

Comprehensive monitoring of temperature, watchdog<br />

Operating hours counter for preventive maintenance<br />

Integrated log functions, comprehensive text messages,<br />

online help (English/German)<br />

Network-wide monitoring via SNMP and O<strong>PC</strong> interface<br />

possible<br />

SIMATIC I<strong>PC</strong> Image & Partition Creator<br />

Software tool for preventive data back-up of the contents of<br />

bulk storage (CF cards, hard disks, SSD)<br />

High-speed restoring of system and data partitions with bit<br />

accuracy; user software and special installations are also<br />

backed up<br />

Software tool for adaptation of mass storage partitioning<br />

SIMATIC I<strong>PC</strong> Service USB FlashDrive<br />

Mobile memory medium for backing up/restoring mass<br />

memories<br />

Pre-installed Image & Partition Creator V3.1<br />

Ultra-compact and rugged


■ Function<br />

Diagnosis<br />

Integrated, parameterizable monitoring functions (program<br />

execution/watchdog, processor and board temperature)<br />

Expanded diagnostics/messages via Ethernet, e-mail, text<br />

message and for direct transfer to SIMATIC software via O<strong>PC</strong><br />

(optionally via SIMATIC I<strong>PC</strong> DiagMonitor)<br />

- Runtime meter<br />

- Hard disk status<br />

- System status (Heart Beat)<br />

- Automatic logging of all alarms by means of a log file<br />

- Capability for central monitoring of networked SIMATIC I<strong>PC</strong><br />

DiagBase: Integrated, parameterizable monitoring functions<br />

(program flowchart/watchdog, internal enclosure<br />

temperature, DIAG bit for CF cards similar to S.M.A.R.T for<br />

hard disks/SSD)<br />

Expanded diagnostics/messages via Ethernet, e-mail, text<br />

message and for direct transfer to SIMATIC software via O<strong>PC</strong><br />

(optionally via SIMATIC I<strong>PC</strong> DiagMonitor)<br />

■ Integration<br />

Integrated interfaces:<br />

Ethernet<br />

The two integrated Gigabit Ethernet interfaces (10/100/<br />

1000 Mbit/s, teaming-capable) can be used for<br />

IT communication and for data exchange with programmable<br />

controllers such as SIMATIC S7 (with the "SOFTNET S7"<br />

software package).<br />

PROFINET<br />

The PROFINET interface can be used for connecting<br />

distributed field devices or for controlling drives<br />

(PROFINET RT via Standard Ethernet).<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>227D<br />

■ Technical specifications<br />

SIMATIC I<strong>PC</strong>227D<br />

General features<br />

Design Rail, wall, portrait or side mounting<br />

Processor Intel Atom E660 1.3 GHz,<br />

2 GB RAM<br />

Intel Atom E640 1.0 GHz,<br />

1 GB RAM<br />

Intel Atom E620 600 MHz,<br />

512 MB RAM<br />

Chipset Intel Controller Hub EG20T<br />

Buffered MRAM 512 KB, of which 128 KB can be<br />

written within the buffer time<br />

Free slots for expansions Optional <strong>PC</strong>Ie expansion slot<br />

Graphics Integrated into Intel Atom CPU<br />

E6xx<br />

8 to 256 MB (shared memory),<br />

1920 x 1200, 60 Hz, 32-bit<br />

colors<br />

Operating system without<br />

Windows XP Embedded<br />

Standard 2009 preinstalled, in<br />

combination with CF card, or<br />

Solid-State Drive, or hard drive<br />

(optional)<br />

Windows XP Professional MUI<br />

(in combination with solid-state<br />

drive or hard drive; MUI: Multi<br />

Language User Interface)<br />

(optional)<br />

Windows 7 Ultimate and Windows<br />

Embedded Standard 7 available<br />

soon<br />

Linux 1) (project-specific, on<br />

request)<br />

Others on request<br />

project-specifically<br />

Design Rail, wall, portrait or side mounting<br />

Power supply 24 V DC (20.4 V ... 28.8 V)<br />

Isolated<br />

With buffering of temporary power<br />

failures: max. 10 ms<br />

Line side switch<br />

With power failure indication by<br />

means of Power Fail signal<br />

Drives<br />

Flash drive Optional; replaceable, accessible,<br />

diagnosable<br />

2GB<br />

4 GB<br />

8GB<br />

Solid State Drive (SSD) Optional 50 GB SATA, 2.5" in<br />

single-level cell (SLC) technology,<br />

especially suitable for industrial<br />

applications<br />

Hard disk Optional 250 GB SATA<br />

CD-ROM Via USB<br />

(not included in scope of delivery)<br />

DVD-RW Via USB<br />

(not included in scope of delivery)<br />

Floppy disk Via USB<br />

(not included in scope of delivery)<br />

5/65<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>227D<br />

■ Technical specifications (continued)<br />

SIMATIC I<strong>PC</strong>227D<br />

Interfaces<br />

PROFINET PROFINET RT via Standard<br />

Ethernet controller<br />

PROFIBUS/MPI -<br />

Ethernet 2 x 10/100/1000 Mbit/s (RJ 45)<br />

Two independent Intel<br />

Controllers:<br />

Intel 82574L / Intel Controller Hub<br />

EG20T<br />

With teaming function<br />

USB V2.0/High Speed: 4 x<br />

Serial COM1 (V.24), optional COM2-4<br />

DVI-I 1 x DVI-D<br />

Keyboard Via USB<br />

(not included in scope of delivery)<br />

Mouse Via USB (not included in scope of<br />

delivery)<br />

Monitoring functions<br />

Temperature Processor temperature<br />

Motherboard<br />

Messages can be evaluated by<br />

the application program<br />

Watchdog Monitoring of program execution<br />

Monitoring time can be parameterized<br />

in software<br />

Can be parameterized for a fault<br />

or restart<br />

Messages can be evaluated by<br />

the application program.<br />

Monitoring functions via the DiagBase<br />

network<br />

SIMATIC I<strong>PC</strong> DiagMonitor<br />

Remote monitoring capability for:<br />

Watchdog<br />

Temperature<br />

Mass memory monitoring<br />

(SMART)<br />

System/Ethernet monitoring<br />

(Heart Beat)<br />

Runtime meter<br />

Communication:<br />

Ethernet interface<br />

(SNMP protocol)<br />

O<strong>PC</strong> for integration in SIMATIC<br />

software<br />

Configuration of client/server<br />

architectures<br />

Layout of log files<br />

5/66<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Ambient conditions<br />

Degree of protection to EN 60529<br />

(front/rear)<br />

Ambient temperature during<br />

operation<br />

Approvals<br />

Marine approval<br />

Only for configurations with<br />

CompactFlash or SSD memory<br />

SIMATIC I<strong>PC</strong>227D<br />

IP20<br />

0 °C up to 50 °C<br />

Available soon<br />

Device versions<br />

Basic version Width x Height x Depth: approx.<br />

191 x 100 x 60 mm<br />

COM 3 additional, integrated serial<br />

interfaces<br />

(COM2-4); only sending/<br />

receiving of data<br />

Width x Height x Depth: approx.<br />

191 x 100 x 89 mm<br />

IO 4 digital inputs/outputs each,<br />

24 V, integrated<br />

Width x Height x Depth: approx.<br />

191 x 100 x 89 mm<br />

<strong>PC</strong>Ie 1 <strong>PC</strong>Ie (x1) slot, integrated<br />

Width x Height x Depth: approx.<br />

191 x 187 x 89 mm<br />

1) Suitable for specific LINUX versions in accordance with the specifications<br />

of the <strong>Siemens</strong> manufacturer's declaration "Suited for LINUX",<br />

see www.siemens.com/simatic-pc/suited-for-linux<br />

(LINUX is a trademark of Linus Torvald).


© <strong>Siemens</strong> AG <strong>2011</strong><br />

Note:<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

■ Ordering data Order No. Order No.<br />

Configuration<br />

Configuration<br />

SIMATIC I<strong>PC</strong>227D On request<br />

SIMATIC I<strong>PC</strong>227D On request<br />

Interfaces: 2 x Gbit LAN (RJ45),<br />

Operating system<br />

1 x serial (COM1), 4 x USB<br />

Without operating system<br />

Processors / memory expansion /<br />

Windows Embedded Standard<br />

retentivity<br />

2009 preinstalled<br />

Atom E660 (1.3 GHz), 2 GB RAM<br />

(CF from 2 GB/SSD/HD)<br />

Atom E660 (1.3 GHz),<br />

2 GB RAM, retentivity<br />

Atom E640 (1.0 GHz), 1 GB RAM<br />

Atom E640 (1.0 GHz),<br />

1 GB RAM, retentivity<br />

Atom E620 (600 MHz),<br />

512 MB RAM<br />

XP-Prof. MUI preinstalled on<br />

SSD / HD<br />

Windows Embedded Standard 7<br />

preinstalled<br />

(CF from 4 GB/SSD/HD)<br />

Windows 7 MUI preinstalled on<br />

SSD / HD<br />

Atom E620 (600 MHz),<br />

Software bundles<br />

512 MB RAM, retentivity<br />

Without RTX/HMI software<br />

Drives<br />

RTX: WinAC RTX 2010<br />

Without drive, with CF slot<br />

RTX-F: WinAC RTX F 2010<br />

250 GB HDD SATA<br />

50 GB solid-state drive SATA<br />

(SLC)<br />

2 GB SIMATIC <strong>PC</strong><br />

CompactFlash<br />

4 GB SIMATIC <strong>PC</strong><br />

CompactFlash<br />

8 GB SIMATIC <strong>PC</strong><br />

CompactFlash<br />

COM interface<br />

COM1: RS232<br />

COM1: RS485<br />

COM1: CAN<br />

HMI: WinCC RT Advanced<br />

128 PT<br />

HMI: WinCC RT Advanced<br />

512 PT<br />

HMI: WinCC RT Advanced<br />

2048 PT<br />

HMI: WinCC RT Advanced<br />

4096 PT<br />

HMI/RTX: RT 128 PT<br />

HMI/RTX: RT 512 PT<br />

HMI/RTX: RT 2048 PT<br />

HMI/RTX: RT 4096 PT<br />

Device versions<br />

Basis<br />

<strong>PC</strong>Ie (1 slot)<br />

COM (COM2-4: RS232)<br />

IO (4x dig. inputs/outputs each)<br />

Mounting accessories<br />

Standard mounting rail<br />

Wall mounting<br />

Portrait mounting<br />

Side mounting<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>227D<br />

Software Packages with SIMATIC WinCC flexible,<br />

SIMATIC WinCC and SIMATIC WinAC RTX (F) can be ordered<br />

together with the SIMATIC I<strong>PC</strong> with a price advantage.<br />

More information under "Embedded Bundles / Packages for<br />

industrial <strong>PC</strong>s".<br />

5/67<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>227D<br />

■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical specifications.<br />

197<br />

60<br />

I<strong>PC</strong>227D basic unit, portrait mounting<br />

198<br />

90.6<br />

I<strong>PC</strong>227D COM version, portrait mounting<br />

5/68<br />

100<br />

105<br />

100<br />

105<br />

21.5<br />

21<br />

2.5<br />

2<br />

231.5<br />

62<br />

231.5<br />

93.1<br />

220<br />

4.8<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

220<br />

14.5<br />

4.8<br />

15<br />

76.6<br />

56<br />

46<br />

28<br />

19<br />

20.3<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00474<br />

G_<strong>ST</strong><strong>80</strong>_XX_00475<br />

<br />

<br />

I<strong>PC</strong>227D basic unit, standard rail mounting<br />

<br />

<br />

50<br />

50<br />

8.5<br />

I<strong>PC</strong>227D COM version, standard rail mounting<br />

8.5<br />

60<br />

90.6<br />

100<br />

100<br />

G_<strong>ST</strong><strong>80</strong>_XX_00464<br />

G_<strong>ST</strong><strong>80</strong>_XX_00465


■ Dimensional drawings (continued)<br />

198<br />

90.6<br />

I<strong>PC</strong>227D <strong>PC</strong>Ie version, portrait mounting<br />

<br />

<br />

187<br />

192<br />

21<br />

2.5<br />

93.5<br />

231.5<br />

93.1<br />

8.5<br />

I<strong>PC</strong>227D <strong>PC</strong>Ie version, standard rail mounting<br />

220<br />

4.8<br />

14.5<br />

90.6<br />

76.6<br />

56<br />

167<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

20.3<br />

G_<strong>ST</strong><strong>80</strong>_XX_00476<br />

G_<strong>ST</strong><strong>80</strong>_XX_00473<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

■ More information<br />

Further information can be found on the Internet at:<br />

www.siemens.com/simatic-pc<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>227D<br />

5/69<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>427C<br />

■ Overview<br />

The Microbox <strong>PC</strong> SIMATIC I<strong>PC</strong>427C is the powerful embedded<br />

industrial <strong>PC</strong> for use at the machine:<br />

Ultra-compact<br />

Maintenance-free<br />

Intel Core2 Duo technology<br />

5/70<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

High data processing speed for high productivity<br />

Up to Core2 Duo 2 x 1.2 GHz, fanless<br />

DDR3 memory technology up to 4 GB<br />

Graphic performance for Vista Aero user interface<br />

Maximum compactness and ruggedness for use directly on<br />

the machine<br />

Low mounting depth, up to 55 °C ambient temperature<br />

Upright mounting as second standard mounting position<br />

(50 °C ambient temperature)<br />

Solid State Drive (SSD) (32 GB, optional), SATA hard disk,<br />

or up to FlashDrive 2-CompactFlash with 8 GB<br />

High degree of industrial functionality and flexibility for<br />

implementing the Embedded solution<br />

Flexible memory concepts (e. g. 2 mass storage units are<br />

possible)<br />

2 x LAN 10/100/1000 Mbit/s connections; teaming capability<br />

Onboard PROFIBUS or PROFINET interface (optional)<br />

4 x high-speed USB 2.0 ports; 2 serial interfaces<br />

(2nd interface is optional)<br />

Flexible installation with mounting options (rail, wall, front<br />

upright mounting)<br />

Easy expansion (up to 3 <strong>PC</strong>I-104 slots), e. g. high-speed,<br />

central I/O<br />

On/Off switch<br />

High system availability in order to reduce the risk of<br />

potential failures and maintenance costs<br />

Maintenance-free since no rotating parts (fans, hard disks)<br />

and no battery are installed<br />

2 MB buffered SRAM, of which 128 KB can be written within<br />

the buffer time<br />

Front LED for efficient self-diagnostics; optimized for headless<br />

operation through special BIOS properties<br />

SIMATIC software system-tested<br />

High investment security in order to reduce engineering<br />

costs<br />

Long-term availability: Service and support period of 8 to<br />

10 years after market launch<br />

Mounting compatibility and interface compatibility with<br />

predecessor versions as of 2004


■ Application<br />

The SIMATIC I<strong>PC</strong>427C provides mechanical engineers, plant<br />

engineers and control cabinet manufacturers with a high-performance,<br />

compact <strong>PC</strong> platform for use at machine or process<br />

level, or in the industrial environment for:<br />

Measuring and checking, open-loop and closed-loop control<br />

of process and machine data<br />

Acquisition, further processing and visualization of data<br />

All applications at the machine level - created in C/C++ or with<br />

WinAC/WinCC flexible - which require rugged, ultra-compact<br />

I<strong>PC</strong>s with high computing power<br />

Additional new applications such as shipbuilding, building<br />

automation, water treatment, RFID<br />

The application spectrum ranges from automation computers<br />

fully integrated in TIA with, for example, WinAC, through C/C++based<br />

automation solutions with the tried and tested SICOMP<br />

RMOS3 operating system with real-time and multi-tasking<br />

capability, all the way to "standalone" applications in general<br />

IT use. For software products that require Windows XP Professional,<br />

the combination of Windows XP Professional multi<br />

language is available preinstalled on the hard disk.<br />

The SIMATIC I<strong>PC</strong>427C has the CE mark for use in the industrial<br />

sector as well as in residential and commercial areas, and small<br />

businesses. In addition to industrial applications, it can also be<br />

used in building services automation or in facilities open to the<br />

public. The device also has the most important marine approvals<br />

(available soon), provided that configurations with Compact-<br />

Flash memory are used.<br />

Due to the fan-free design and use of SIMATIC <strong>PC</strong> Compact-<br />

Flash memories, there are no rotating parts and the system availability<br />

is increased. It is possible to order the CompactFlash<br />

memory either accessible externally so that it can be swapped,<br />

or integrated so that it is protected against access.<br />

The SIMATIC <strong>PC</strong>s can be ordered in connection with<br />

WinCC flexible, WinCC or WinCC V11 (Advanced, Professional)<br />

as SIMATIC HMI packages at favorable prices.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Design<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>427C<br />

Basic design<br />

All-metal enclosure, resistant to vibrations and shocks, also<br />

with high electromagnetic compatibility<br />

Graphics onboard, on AGP bus: DVI-I: VGA (analog) and DVI<br />

(digital)<br />

- CRT resolution: up to 1920 x 1200 pixels / true color /<br />

60 to 120 Hz<br />

- DVI-D resolution: up to 1920 x 1200 pixels / true color<br />

Optical drives can be connected externally via USB interface,<br />

not included in scope of supply<br />

Interfaces (accessible from one side):<br />

- 2 x LAN 10/100/1000 Mbit/s Ethernet interface (RJ45)<br />

- 4 x high-speed USB V2.0<br />

- 1 x COM1 (RS232)<br />

Free slots (when using the expansion rack):<br />

- Up to 3 x <strong>PC</strong>I104-Plus cards<br />

Isolated power supply: 24 V DC (19.2 to 28.8 V)<br />

Design versions<br />

Processor:<br />

- Intel Core2 Duo 1.2 GHz, <strong>80</strong>0 MHz FSB, 3 MB SLC<br />

- Intel Core2 Solo 1.2 GHz, <strong>80</strong>0 MHz FSB, 3 MB SLC<br />

- Intel Celeron M 1.2 GHz, <strong>80</strong>0 MHz FSB, 1 MB SLC<br />

Main memory expansion of 1 GB (2/4 GB optional),<br />

DDR3 SDRAM<br />

Fieldbus<br />

- PROFINET onboard, 3 x RJ45, CP 1616-compatible<br />

- PROFIBUS DP/MPI on board, compatible with CP 5611<br />

Hardware expansion:<br />

- Second RS232 interface (COM2) in expansion rack<br />

Drives:<br />

- Solid-state drive, 32 GB, rugged alternative to hard disk<br />

- Flash drive (replaceable, accessible): 256 MB, 2 GB, 4 GB<br />

or 8 GB<br />

- Flash drive (internal, not accessible): 256 MB, 2 GB, 4 GB,<br />

8GB<br />

- Hard disk serial ATA, 2.5"<br />

Preinstalled operating systems:<br />

- Windows XP Embedded Standard 2009<br />

(successor to Windows XP Embedded)<br />

- Windows XP Professional multi language<br />

- Windows 7 Ultimate MUI<br />

- Windows Embedded Standard 7<br />

5/71<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>427C<br />

■ Design (continued)<br />

SIMATIC I<strong>PC</strong>427C (bottom side), PROFIBUS version<br />

SIMATIC I<strong>PC</strong>427C (bottom side), PROFINET version<br />

5/72<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Function<br />

Integrated and parameterizable monitoring functions<br />

(program execution/watchdog, processor and board<br />

temperature)<br />

Expanded diagnostics/messages via Ethernet, e-mail, text<br />

message and for direct transfer to SIMATIC software via O<strong>PC</strong><br />

(optionally via SIMATIC <strong>PC</strong> DiagMonitor)<br />

- Runtime meter<br />

- Hard disk status<br />

- System status (heartbeat)<br />

- Automatic logging of all alarms by means of a log file<br />

- Possibility for central monitoring of a networked SIMATIC <strong>PC</strong><br />

■ Integration<br />

Integrated interfaces:<br />

Ethernet<br />

The two integrated Gigabit Ethernet interfaces (10/100/<br />

1000 Mbit/s) can be used for IT communication and for data<br />

exchange with programmable controllers such as SIMATIC S7<br />

(with the "SOFTNET S7" software package).<br />

PROFIBUS<br />

The optional floating PROFIBUS interface (12 Mbit/s) can be<br />

used to connect distributed field devices or for coupling to the<br />

SIMATIC S7 (with the "SOFTNET for PROFIBUS" software<br />

package).<br />

PROFINET<br />

The PROFINET interface can be used for connecting<br />

distributed field devices or for controlling drives.<br />

Further interfaces<br />

For connecting additional I/O devices, up to three free slots<br />

are available for <strong>PC</strong>I-104 modules (with expansion frames), as<br />

well as 4 high-speed USB interfaces and two serial interfaces.


■ Technical specifications<br />

SIMATIC I<strong>PC</strong>427C<br />

General features<br />

Design DIN rail or wall mounting, front<br />

upright mounting, mounting<br />

position preferably horizontal,<br />

vertical possible<br />

Processor Intel Core2 Duo 1.2 GHz,<br />

<strong>80</strong>0 MHz FSB, 3 MB SLC<br />

Intel Core2 Solo 1.2 GHz,<br />

<strong>80</strong>0 MHz FSB, 3 MB SLC<br />

Intel Celeron M 1.2 GHz,<br />

<strong>80</strong>0 MHz FSB, 1 MB SLC<br />

Chipset Intel GM45 / ICH9M<br />

Main memory 1 GB, (2/4 GB) DDR3 SDRAM<br />

Buffered SRAM 2 MB, of which 128 KB can be<br />

written within the buffer time<br />

Free slots for expansions Up to 3 x <strong>PC</strong>I-104, 3 W per slot<br />

Graphics Integrated Intel GMAX4500<br />

graphics<br />

8 ... 512 MB shared graphics<br />

memory (managed dynamically)<br />

CRT resolution: 640 x 4<strong>80</strong> pixels<br />

up to max. 1920 x 1200 pixels at<br />

32 bit colors<br />

DVI-D resolution: 640 x 4<strong>80</strong> pixels<br />

up to max. 1920 x 1200 pixels at<br />

32 bit colors<br />

Operating system without<br />

Windows XP Embedded<br />

Standard 2009 preinstalled, in<br />

combination with CF card of 2 GB<br />

or more, solid-state drive, or hard<br />

drive<br />

Windows XP Professional MUI<br />

(in combination with solid-state<br />

drive or hard drive; MUI: Multi<br />

Language User Interface)<br />

Windows 7 Ultimate MUI or<br />

Windows Embedded Standard 7<br />

RMOS3 (order separately)<br />

Linux1) (project-specific, on<br />

request)<br />

Others on request<br />

project-specifically<br />

Power supply 24 V DC (19.2 V ... 28.8 V)<br />

Isolated<br />

With buffering of temporary<br />

power failures: Max. 10 ms at<br />

0.85% rated voltage<br />

Line side switch<br />

With power failure indication by<br />

means of Power Fail signal<br />

Drives<br />

Flash drive Optional; replaceable,<br />

accessible, diagnosable<br />

256MB<br />

2GB<br />

4GB<br />

8GB<br />

Optional; internal, not<br />

accessible, diagnosable<br />

256MB<br />

2GB<br />

4GB<br />

8GB<br />

1) Suitable for specific LINUX versions in accordance with the specifications<br />

of the <strong>Siemens</strong> manufacturer's declaration "Suited for LINUX",<br />

see www.siemens.com/simatic-pc/suited-for-linux<br />

(LINUX is a trademark of Linus Torvald).<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>427C<br />

Solid-State Drive (SSD) Optional<br />

32 GB SATA, 2.5" in single-level<br />

cell (SLC) architecture, especially<br />

suitable for industrial applications<br />

Hard disk Optional<br />

> 250 GB SATA<br />

CD-ROM Via USB (not included in scope of<br />

delivery)<br />

DVD-RW Via USB (not included in scope of<br />

delivery)<br />

Disk Via USB (not included in scope of<br />

delivery)<br />

Interfaces<br />

PROFINET 3 x RJ45 (CP 1616-compatible,<br />

optional)<br />

PROFIBUS/MPI 12 Mbit/s (isolated, compatible to<br />

CP 5611)<br />

optional<br />

Ethernet 2 x 10/100/1000 Mbit/s (RJ 45)<br />

Two independent Intel 82574L<br />

controllers (via <strong>PC</strong>I-Express)<br />

One controller with none-shared<br />

interrupt<br />

Team capability<br />

USB V2.0/High Speed: 4 x<br />

Serial COM1 (V.24)<br />

COM2 (V.24) optional<br />

(in expansion frame)<br />

DVI-I 1 x DVI-I (includes DVI-D and VGA)<br />

Keyboard Via USB (not included in scope of<br />

delivery)<br />

Mouse Via USB (not included in scope of<br />

delivery)<br />

Monitoring functions<br />

Temperature Processor temperature<br />

Motherboard<br />

Messages can be evaluated by<br />

the application program<br />

Watchdog Monitoring of program execution<br />

Monitoring time can be parameterized<br />

in software<br />

Can be parameterized for a fault<br />

or restart<br />

Messages can be evaluated by<br />

the application program.<br />

Monitoring functions via the<br />

network<br />

SIMATIC I<strong>PC</strong>427C<br />

DiagBase<br />

SIMATIC I<strong>PC</strong> DiagMonitor<br />

Remote monitoring capability for:<br />

Watchdog<br />

Temperature<br />

Mass memory monitoring<br />

(SMART)<br />

System/Ethernet monitoring<br />

(Heart Beat)<br />

Runtime meter<br />

Communication:<br />

Ethernet interface<br />

(SNMP protocol)<br />

O<strong>PC</strong> for integration in SIMATIC<br />

software<br />

Configuration of client/server<br />

architectures<br />

Layout of log files<br />

5/73<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>427C<br />

■ Technical specifications (continued)<br />

Ambient conditions<br />

Degree of protection to EN 60529 IP20<br />

(front/rear)<br />

Vibration load during operation Devices without hard disk:<br />

Requirements according to:<br />

IEC 61131-2<br />

Tested according to:<br />

IEC 60068-2-6, Test Fc<br />

Devices without drive:<br />

- 5-9 Hz, 3.5 mm deviation,<br />

10x /axis, 1 octave/min<br />

-9-150Hz, 9.8m/s2 , 10x /axis,<br />

1 octave/min<br />

Devices with hard disk:<br />

Wall mounting<br />

Requirements according to:<br />

IEC 61131-2<br />

Tested according to:<br />

IEC 60068-2-6, Test Fc<br />

10 ... 58 Hz, 0.0375 mm<br />

deviation, 10x /axis, 1 octave/min<br />

58 ... 200 Hz, 4.9 m/s2 , 10x /axis,<br />

1 octave/min<br />

Shock load during operation Devices without hard disk:<br />

Requirements according to:<br />

IEC 61131-2<br />

Tested according to:<br />

IEC 60068-2-27, Test Ea<br />

Module/rack: 150 m/s2 , powerup,<br />

11 ms shock duration<br />

Devices with hard disk:<br />

Wall mounting<br />

Requirements according to:<br />

IEC 61131-2<br />

Tested according to:<br />

IEC 60068-2-27, Test Ea<br />

Devices with drive: 50 m/s2 ,<br />

power-up, 30 ms shock duration<br />

Electromagnetic compatibility<br />

(EMC)<br />

Emitted interference EN 55022 Class B<br />

Interference immunity, burst EN 61000-6-2 or IEC 61131-2:<br />

2 kV - Tested acc. to<br />

IEC 61000-4-4<br />

1 kV symmetrical / 2 kV<br />

asymmetrical - Tested acc. to<br />

IEC 61000-4-5<br />

Interference immunity, surge 1 kV to IEC 61000-4-5;<br />

symmetrical<br />

2 kV to IEC 61000-4-5;<br />

asymmetrical<br />

ESD interference immunity According to NAMUR Recommendation<br />

NE 21 and EN 61000-6-2:<br />

6 kV contact discharge - Tested<br />

acc. to IEC 61000-4-2<br />

8 kV air discharge - Tested acc. to<br />

IEC 61000-4-2<br />

Immunity to high radio frequency<br />

interference<br />

Immunity to high-frequency<br />

current feed<br />

5/74<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>427C<br />

According to EN 61000-6-2 or<br />

IEC 61131-2:<br />

Interference immunity<br />

<strong>80</strong> ... 1000 MHz: 10 V/m with <strong>80</strong>%<br />

AM (1 kHz); tested acc. to<br />

IEC 61000-4-3;<br />

1.4 GHz ... 2 Hz: 10 V/m with 50%<br />

pulse modulation; tested<br />

according to IEC 61000-4-3<br />

Acc. to NAMUR Recommendation<br />

NE 21 and EN 61000-6-2 or<br />

IEC 61131-2:<br />

10 kHz ... <strong>80</strong> MHz: 10 V with <strong>80</strong>%<br />

AM (1 kHz) tested acc. to<br />

IEC 61000-4-6<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>427C<br />

Electromagnetic compatibility<br />

(EMC)<br />

Immunity to magnetic fields Acc. to NAMUR Recommendation<br />

NE 21 and EN 61000-6-2 or<br />

IEC 61131-2:<br />

50/60 Hz; 100 A/m rms value -<br />

tested acc. to IEC 61000-4-8<br />

Ambient temperature during<br />

operation<br />

0 ... 55 ºC with flash drive/SSD<br />

(horizontal; preferred mounting<br />

position; with derating)<br />

0 ... 50 ºC with flash drive/SSD<br />

(horizontal; preferred mounting<br />

position; maximum configuration)<br />

0 ... 50 ºC with flash drive/SSD<br />

(vertical)<br />

5 ... 40 ºC with hard disk<br />

(horizontal and vertical)<br />

Moist heat With CompactFlash card/SSD:<br />

95%<br />

With hard drive <strong>80</strong>%<br />

System-tested SIMATIC<br />

Industrial Software<br />

WinAC RTX (F), WinCC flexible,<br />

WinCC (SCADA as of V7.0),<br />

WinCC RT Advanced and Professional<br />

Approvals<br />

Marine approval (available soon) GL - Germanische Lloyd<br />

Only for configurations with<br />

BV - Bureau Veritias<br />

CompactFlash or SSD memory LR - Lloyds Register of Shipping<br />

ABS - American Bureau of<br />

Shipping<br />

DNV - Det Norske Veritas<br />

NKK - Nippon Kaiji Kyokai<br />

Safety regulations IEC 61131-2<br />

IEC 61010-1<br />

EN 60950-1<br />

Approvals UL508, UL60950, cULus<br />

CE mark EC Directive 89/336/EEC<br />

(EMC Directive)<br />

Use in industry:<br />

Applications in residential areas,<br />

business and trade environments<br />

as well as in workshops:<br />

- Emitted interference:<br />

EN 61000-6-4<br />

- Noise immunity: EN 61000-6-2<br />

Applications in residential areas,<br />

business and trade environments<br />

as well as in workshops:<br />

- Emitted interference<br />

EN 61000-6-3<br />

- Noise immunity: EN 61000-6-1<br />

Dimensions and weights<br />

Equipment dimensions (in mm) Width x height: 262 x 134<br />

Depth of basic unit: 47<br />

Depth of basic unit above rail: 50<br />

Additional depth per expansion<br />

(1-3): 17 each<br />

Weight, approx. 2 kg


<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

■ Ordering data Order No. Order No.<br />

Configuration<br />

Configuration<br />

1<br />

SIMATIC I<strong>PC</strong>427C<br />

Intel Celeron M 1.2 MHz,<br />

<strong>80</strong>0 MHz FSB, SLC 0 KB; 512 MB<br />

DDR3 RAM; without HD; without<br />

flash drive; without operating<br />

system; 24 V DC industrial power<br />

supply<br />

Processor/motherboard<br />

D 6ES7 647 - 17 B 7 77- 7 7 7 0<br />

Intel Celeron M 1.2 GHz,<br />

<strong>80</strong>0 MHz FSB<br />

A<br />

Intel Celeron M 1.2 GHz,<br />

<strong>80</strong>0 MHz FSB, PROFIBUS<br />

B<br />

Intel Celeron M 1.2 GHz,<br />

<strong>80</strong>0 MHz FSB, CAN<br />

D<br />

Core2 Solo 1.2 GHz, <strong>80</strong>0 MHz<br />

FSB SLC, 3 MB<br />

E<br />

Core2 Solo 1.2 GHz, <strong>80</strong>0 MHz<br />

FSB SLC, 3 MB, PROFIBUS<br />

F<br />

Core2 Solo 1.2 GHz, <strong>80</strong>0 MHz<br />

FSB SLC, 3 MB, PROFINET<br />

G<br />

Core2 Duo 1.2 GHz, <strong>80</strong>0 MHz<br />

FSB SLC, 3 MB<br />

J<br />

Core2 Duo 1.2 GHz, <strong>80</strong>0 MHz<br />

FSB SLC, 3 MB, PROFIBUS<br />

K<br />

Core2 Duo 1.2 GHz, <strong>80</strong>0 MHz<br />

FSB SLC, 3 MB, PROFINET<br />

Memory expansion:<br />

L<br />

1 GB DDR3 1066, SODIMM 2<br />

2 GB DDR3 1066, SODIMM 3<br />

4 GB DDR3 1066, SODIMM<br />

Expansion (HW):<br />

4<br />

No expansion (HW) 0<br />

Second RS232 interface in<br />

expansion rack<br />

1<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

1) For an up-to-date overview, see the SIMATIC <strong>PC</strong> online configurator<br />

at: www.siemens.com/ipc-configurator<br />

2) XP Embedded on 2 GB CompactFlash or hard disk.<br />

XP Professional or Windows 7 only with hard disk/SSD.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>427C<br />

1<br />

SIMATIC I<strong>PC</strong>427C<br />

Drives exchangeable<br />

(accessible)<br />

D 6ES7 647 - 17 B 7 7 7 - 777 0<br />

Without drive 0<br />

256 MB CompactFlash 1<br />

2 GB CompactFlash 2<br />

4 GB CompactFlash 3<br />

8 GB CompactFlash<br />

Drives internal (not accessible)<br />

4<br />

Without internal drive X<br />

250 GB HDD SATA A<br />

32 GB solid-state drive SATA D<br />

256 MB CompactFlash internal M<br />

2 GB CompactFlash internal N<br />

4 GB CompactFlash internal P<br />

8 GB CompactFlash internal<br />

Operating system<br />

(preinstalled and activated)<br />

Q<br />

2)<br />

Without operating system X<br />

Windows Embedded Standard<br />

2009 preinstalled on internal<br />

drive<br />

A<br />

Windows XP Professional MUI<br />

preinstalled on internal drive<br />

B<br />

Windows 7 Embedded Standard<br />

preinstalled on internal drive<br />

C<br />

Windows 7 Ultimate MUI<br />

preinstalled on internal drive<br />

D<br />

5/75<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>427C<br />

■ Ordering data Order No. Order No.<br />

Accessories<br />

Portrait assembly kit<br />

Memory expansion<br />

Interfaces to the front A 6ES7 648-1AA20-0YB0<br />

1 GB DDR3 1066 SDRAM,<br />

SODIMM<br />

2 GB DDR3 1066 SDRAM,<br />

SODIMM<br />

4 GB DDR3 1066 SDRAM,<br />

SODIMM<br />

A<br />

A<br />

A<br />

6ES7 648-2AH40-0KA0<br />

6ES7 648-2AH50-0KA0<br />

6ES7 648-2AH60-0KA0<br />

SIMATIC <strong>PC</strong> keyboard<br />

German/international, USB port<br />

SIMATIC <strong>PC</strong> keyboard<br />

German/international, USB port,<br />

incl. 4-port USB hub<br />

A<br />

6ES7 648-0CB00-0YA0<br />

6ES7 648-0CD00-0YA0<br />

Expansion kit <strong>PC</strong>/104 A 6ES7 648-2AH30-0KA0<br />

USB mouse<br />

A<br />

(optical, 3-button) for PG and <strong>PC</strong><br />

6ES7 790-0AA01-0XA0<br />

For integration of <strong>PC</strong>/104 modules<br />

with adapter<br />

in the SIMATIC Microbox <strong>PC</strong>;<br />

packing unit contains<br />

6 expansion frames<br />

SIMATIC <strong>PC</strong> CompactFlash<br />

256MB A 6ES7 648-2BF02-0XC0<br />

SIMATIC <strong>PC</strong> adapter cable<br />

DVI-I to VGA, 250 mm<br />

6ES7 648-3AB00-0XA0<br />

2GB<br />

4GB<br />

8GB<br />

A<br />

A<br />

A<br />

6ES7 648-2BF02-0XF0<br />

6ES7 648-2BF02-0XG0<br />

6ES7 648-2BF02-0XH0<br />

SIMATIC <strong>PC</strong> USB FlashDrive<br />

8 GB, USB 2.0, metal enclosure,<br />

bootable<br />

A 6ES7 648-0DC50-0AA0<br />

SIMATIC I<strong>PC</strong> Service USB<br />

FlashDrive<br />

8 GB, USB 2.0, metal enclosure,<br />

bootable, with BIOS-Manager,<br />

Image & Partition Creator preinstalled,<br />

incl. CD<br />

B 6AV7 672-8JD01-0AA0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

Note:<br />

Software Packages with SIMATIC WinCC flexible, SIMATIC WinCC and<br />

SIMATIC WinAC RTX (F) can be ordered together with the SIMATIC I<strong>PC</strong><br />

with a price advantage.<br />

More information under "Embedded Bundles / Packages for<br />

industrial <strong>PC</strong>s".<br />

5/76<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Accessories<br />

SIMATIC I<strong>PC</strong>427C with expansion rack; a maximum of 4 <strong>PC</strong>-IO<br />

expansion racks can be stacked.<br />

For particularly fast and real-time-capable measuring, open-and<br />

closed-loop control tasks, the SIMATIC I<strong>PC</strong>427C can be<br />

modularly and flexibly expanded by a central <strong>PC</strong>-I/O.<br />

By means of <strong>PC</strong>I-104 expansion slots, encoders/counters as<br />

well as digital and analog I/O modules can be integrated using<br />

expansion racks in an extremely compact configuration.<br />

The base module <strong>PC</strong> I/O Base 400 is plugged directly into the<br />

<strong>PC</strong>104 slot of the SIMATIC I<strong>PC</strong>427C, and any encoders/counters<br />

required are routed externally via the KIT 040 (encoder<br />

expansion rack).<br />

One or two I/O modules are screwed into the KIT 030 and<br />

attached with this to the enclosure of the SIMATIC I<strong>PC</strong>427C,<br />

while the electrical connection to the <strong>PC</strong> IO Base 400 is made<br />

using flat ribbon cables. The I/O can be connected by means<br />

of direct connectors.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>427C<br />

Module Description<br />

<strong>PC</strong> IO Base 400 (base module) <strong>PC</strong>I104 interface to the host<br />

4 encoder inputs, optionally<br />

usable individually as counters<br />

4 digital inputs<br />

Management of the encoder<br />

inputs and associated counters,<br />

as well as up to 4 I/O modules<br />

via their own communications<br />

interfaces<br />

Power supply distribution for<br />

4 encoders<br />

<strong>PC</strong> IO MOD digital 010<br />

24 binary inputs 24 V<br />

(digital I/O module 0)<br />

16 binary outputs 24 V<br />

<strong>PC</strong> IO MOD analog 020<br />

8 analog inputs, 12 bit, 0 ... 5 V,<br />

(analog I/O module 0)<br />

0 ... 10 V ±5 V, ±10 V<br />

8 analog outputs, 16 bit, ±10 V<br />

4 Pt100 connections, 2-wire<br />

<strong>PC</strong> IO KIT 040<br />

Connection unit for:<br />

(encoder expansion rack)<br />

4 encoder inputs<br />

4 digital inputs<br />

Encoder voltage feed<br />

<strong>PC</strong> IO KIT 030<br />

Expansion rack for accepting<br />

(I/O expansion rack)<br />

max. 2 I/O modules in the<br />

SIMATIC I<strong>PC</strong>427C system<br />

5/77<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>427C<br />

■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical specifications.<br />

■ More information<br />

Further information can be found on the Internet at:<br />

www.siemens.com/simatic-pc<br />

5/78<br />

262<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

133<br />

46.5<br />

138<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<br />

262 138<br />

52.5<br />

97.5<br />

G_<strong>ST</strong><strong>80</strong>_XX_00456


■ Overview<br />

The SIMATIC I<strong>PC</strong>627C Box <strong>PC</strong> is ideally suited to high-performance<br />

<strong>PC</strong> applications installed at the machine.<br />

It offers:<br />

maximum performance in the smallest space<br />

Intel Core i7 technology<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>627C<br />

Maximum system performance for complex measuring,<br />

control and visualization tasks<br />

Intel processors: Core i7, Core i3 or Celeron; in each case with<br />

2 cores, with turbo-boost technology and AMT (i7) and hyperthreading<br />

(i7, i3)<br />

Intel BD82QM57 Platform Controller Hub (<strong>PC</strong>H)<br />

DDR3 1066 memory technology up to 8 GB RAM<br />

Intel HD graphics media accelerator for high graphic<br />

performance<br />

<strong>PC</strong>I Express x16 slot for x16 graphic card support<br />

SATA hard disks with up to 500 GB capacity and NCQ<br />

technology (Native Command Queuing) for larger data<br />

volumes<br />

Highly compact design for space-saving and flexible<br />

installation<br />

Compact housing design (volume 6 liters)<br />

Flexible installation in many different positions with mounting<br />

brackets or portrait installation kits<br />

Free expansion slots: 2 x <strong>PC</strong>I or optionally 1 x <strong>PC</strong>I-Express x16<br />

and 1 x <strong>PC</strong>I<br />

3 x PROFINET interfaces onboard (optional, IRT-capable,<br />

3-port, switching-enabled, CP 1616-compatible)<br />

1 x PROFIBUS interface onboard (optional,<br />

CP 5611-compatible)<br />

RAID1 controller onboard (no occupation of a <strong>PC</strong> slot)<br />

2 x LAN 10/100/1000 Mbit/s connections (Gbit LAN with<br />

teaming capability)<br />

4 x USB ports 2.0 (high current)<br />

DVI-I interface (for VGA and/or DVI-D monitors)<br />

Rugged design for direct installation in the machine<br />

Maximum processor performance up to ambient temperature<br />

of 55 °C<br />

High shock/vibration resistance in all possible mounting<br />

positions<br />

High EMC for safe operation<br />

SATA Solid-State Drive (SSD) with 32 GB in Single Level Cell<br />

architecture (SLC) for high reliability and speed<br />

2 x CompactFlash drives (one optional)<br />

Strain relief for all cables/connectors<br />

5/79<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>627C<br />

■ Benefits (continued)<br />

High system availability, fast startup, maintenance and<br />

servicing<br />

High data security thanks to mirror disk system<br />

(RAID1, optional) or solid-state drive (SSD, optional)<br />

ECC memory (optional, for 1-bit error correction)<br />

2 MB battery-buffered SRAM, 128 KB of which can be used as<br />

memory for retentive WinAC RTX data<br />

AMT (Intel Active Management Technology) functionality for<br />

remote access to I<strong>PC</strong> (remote maintenance)<br />

CMOS buffer battery accessible from outside, replaceable<br />

during operation. Status can be scanned by software<br />

Two 7-segment displays and 2 signal LEDs (two-color) for<br />

diagnostics purposes, freely programmable<br />

Operating system preinstalled, ready to run, and already<br />

activated (eliminates need for usual product activation via the<br />

Internet or by telephone)<br />

Following system failure, fast restoration of hard disk contents<br />

to as-delivered status using supplied recovery and restore CD<br />

Worldwide service and support<br />

Cost reductions through high investment security<br />

Platform with long-term stability and embedded Intel<br />

components<br />

Availability of 3 to 5 years, then guaranteed availability of<br />

spare parts for further 5 years<br />

Part of the scalable Box <strong>PC</strong> range with identical performance<br />

features and footprint<br />

System-tested with SIMATIC components<br />

Certification for worldwide marketing (e. g.: cULus)<br />

Installation compatible for all device generations, software<br />

compatible with predecessor model<br />

5/<strong>80</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Application<br />

The SIMATIC I<strong>PC</strong>627C provides mechanical engineers, plant<br />

engineers, and control cabinet makers with a high-performance,<br />

compact <strong>PC</strong> platform for application at the machine or in the<br />

industrial environment for:<br />

Measuring and controlling of process and machine data<br />

(e. g. automated washing systems, robot controls)<br />

Operating and visualization tasks with separate display/<br />

monitor solutions (e. g. information terminals, large-scale<br />

displays in automotive production)<br />

Data acquisition and processing (e. g. production data<br />

acquisition, distributed process control)<br />

Motion Control<br />

The SIMATIC I<strong>PC</strong>627C has CE certification for use in the industrial<br />

sector as well as in residential and commercial areas, and<br />

small businesses. In addition to industrial applications, it can<br />

also be used in building service automation or in facilities open<br />

to the public.<br />

It can also be integrated in confined spaces thanks to the low<br />

mounting depth of 100 mm (<strong>80</strong> mm without CD drive).<br />

The SIMATIC Box <strong>PC</strong>s can be ordered in combination with<br />

WinCC flexible or WinCC as SIMATIC HMI packages at a<br />

reduced price.<br />

■ Design<br />

Basic design<br />

Rugged metal enclosure, resistant to vibration and shock, with<br />

high electromagnetic compatibility<br />

Card retainer for reliable operation of <strong>PC</strong> modules in the event<br />

of vibrations and shocks<br />

Graphics onboard 1600 x 1200, 85 Hz, 32-bit colors<br />

Interfaces (accessible from one side):<br />

- 2 x LAN 10/100/1000 Mbit/s Ethernet interface (RJ45)<br />

- DVI-I graphic interface<br />

-4x USB 2.0<br />

- 1 x serial (COM1)<br />

CompactFlash drive (can be operated from outside)<br />

Two 7-segment displays (Port <strong>80</strong>) and two dual-color LEDs for<br />

status indication (freely programmable)


■ Design (continued)<br />

Design versions<br />

Processor:<br />

- Intel Core i7-610E processor (2C/4T, 2.53 GHz, TB, HT, VT,<br />

AMT, 4 MB cache)<br />

- Intel Core i3-330E processor (2C/4T, 2.13 GHz, HT, VT,<br />

3 MB cache)<br />

- Intel Celeron P4505 processor (2C/2T, 1.86 GHz,<br />

2 MB cache)<br />

Main memory<br />

- 1 GB to 4 GB, DDR3 1066<br />

- ECC memory 2 GB/4 GB, DDR3 1066<br />

Fieldbus:<br />

- PROFINET onboard, IRT-capable, switching-enabled,<br />

3 x RJ45, CP 1616-compatible, PROFINET versions feature<br />

onboard 2 MB SRAM with battery back-up<br />

- PROFIBUS/MPI onboard, CP 5611-compatible, PROFIBUS<br />

versions feature 2 MB SRAM with battery back-up onboard<br />

Drives:<br />

- SATA hard disks: 250/500 GB, 3.5";<br />

RAID1 2 x 250 GB, 2.5"<br />

- SATA solid state drive 32 GB (SSD) in single level cell architecture<br />

(SLC)<br />

- Second CompactFlash drive (internal) instead of HDD,<br />

ODD, without CF<br />

- Optical drives SATA DVD+/-RW/-RAM/-DL<br />

Free slots for expansions:<br />

- 2 x <strong>PC</strong>I (175/265 mm) or<br />

- 1 x <strong>PC</strong>I-Express x16 (175 mm) and 1 x <strong>PC</strong>I (265 mm)<br />

Power supply:<br />

- 100/240 V AC (wide range), 50/60 Hz<br />

- 24 V DC industrial power supply<br />

Preinstalled operating systems:<br />

- Windows XP Professional, multi language<br />

- Windows 7 Ultimate, multi language<br />

- Windows Embedded Standard 2009 English (XP-based,<br />

on 8 GB CompactFlash)<br />

SIMATIC I<strong>PC</strong> DiagMonitor 1)<br />

SIMATIC I<strong>PC</strong> Image Creator 1)<br />

1) Further information can be found under "Expansion components".<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>627C<br />

■ Function<br />

Integrated, parameterizable monitoring functions (program<br />

execution (watchdog), internal enclosure temperature,<br />

external enclosure temperature, speed monitoring of fans,<br />

CMOS battery)<br />

Extended diagnostics/alarms via Ethernet, e-mail, text<br />

message and for direct infeed into the SIMATIC software via<br />

O<strong>PC</strong> and logging (optionally via SIMATIC <strong>PC</strong> DiagMonitor):<br />

- Runtime meter<br />

- Hard disk status<br />

- Automatic logging of all alarms by means of a log file<br />

- Long-term recording and graphic display of measured<br />

values (temperature, fan)<br />

- Capability for central monitoring of networked SIMATIC <strong>PC</strong>s<br />

RAID1 for automatic data mirroring on two serial ATA hard<br />

disks<br />

Flash drive, via CompactFlash card or solid-state drive<br />

accessible from outside, for especially rugged data storage<br />

and systems without hard drive<br />

AMT functionality (Intel Active Management Technology).<br />

This property permits remote access to the I<strong>PC</strong> (for servicing),<br />

even when the operating system is shut down, e. g.:<br />

- Starting/shutdown of the I<strong>PC</strong><br />

- BIOS update<br />

CMOS batteries are externally accessible and therefore easily<br />

replaced<br />

Flash BIOS with the ability to store customer-specific CMOS<br />

settings in a non-volatile memory area<br />

The PROFINET and PROFIBUS versions offer 2 MB of batterybacked<br />

SRAM for application data<br />

After an unexpected power interruption, up to 128 KB of<br />

important process data can be written to the battery-backed<br />

SRAM<br />

Two 7-segment displays (Port <strong>80</strong>) for the power-up display<br />

and for customer outputs (user-programmable)<br />

Two 2-color LEDs (green/red) for the indication of status<br />

messages (user-programmable)<br />

■ Integration<br />

Integrated interfaces:<br />

Ethernet<br />

Two integrated Ethernet interfaces (10/100/1000 Mbit/s) for<br />

IT communication and for exchanging data with automation<br />

devices such as SIMATIC S7 (with the software package<br />

"SOFTNET S7").<br />

PROFINET<br />

The optional PROFINET interface for connecting distributed<br />

field devices or for controlling drives.<br />

PROFIBUS<br />

The optional floating PROFIBUS interface (12 Mbit/s) can be<br />

used to connect distributed field devices or to interface to the<br />

SIMATIC S7 (with the "SOFTNET for PROFIBUS" software<br />

packages).<br />

Further interfaces<br />

There are two spare slots for <strong>PC</strong> modules, 4 USB (Universal<br />

Serial Bus) and a serial interface for connecting additional<br />

I/O devices.<br />

5/81<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>627C<br />

■ Technical specifications<br />

SIMATIC I<strong>PC</strong>627C<br />

General features<br />

Design Panel mounting device, box<br />

Processor Intel Core i7-620E processor<br />

(2C/4T, 2.53 GHz, 4 MB L2,<br />

turbo boost, VT-d, AMT)<br />

Intel Core i3-330E processor<br />

(2C/4T, 2.13 GHz, 3 MB L2)<br />

Intel Celeron P4505 processor<br />

(2C/2T, 1.86 GHz, 2 MB L2)<br />

Chipset Intel Platform Controller Hub<br />

BD82QM57<br />

Main memory 1 GB; DDR3 1066, DIMM;<br />

expandable up to 4 GB,<br />

(2 memory bases)<br />

ECC memory 2/4 GB optional<br />

Free slots for expansions 1 x <strong>PC</strong>I (265 mm) and<br />

1 x <strong>PC</strong>I (175 mm)<br />

or<br />

1 x <strong>PC</strong>I (265 mm) and<br />

1 x <strong>PC</strong>Iexpress x16 (175 mm)<br />

Graphics Onboard, Intel HD graphics,<br />

256 MB (Dynamic Shared<br />

Memory),<br />

VGA: 1600 x 1200 / 32 bit colors /<br />

85 Hz,<br />

DVI-I: 1600 x 1200 / 32 bit colors /<br />

60 Hz,<br />

LCD: 12<strong>80</strong> x 1024 / 18 bit<br />

Operating system without<br />

Preinstalled, activated, and<br />

supplied on restore DVD:<br />

XP Prof. MUI, SP3<br />

Windows 7 Ultimate MUI<br />

Windows Embedded Standard<br />

2009 English on 8 GB Compact-<br />

Flash<br />

MUI: Multi User Interface;<br />

5 languages (English, French,<br />

German, Italian, Spanish)<br />

RMOS3 (separately orderable)<br />

Project-specific on request<br />

Linux 1)<br />

Other<br />

Power supply 100/240 V AC, 190 W;<br />

wide range; with short-term<br />

bridging of power failures in<br />

accordance with NAMUR: max.<br />

20 ms at 93 V or 264 V<br />

50 to 60 Hz (47 to 63 Hz)<br />

24 V DC, 210 W isolated<br />

(optional)<br />

Drives<br />

Hard disk without<br />

250 GB SATA, 3.5"<br />

500 GB SATA, 3.5"<br />

2 x 250 GB SATA, 2.5"<br />

RAID1, 2 x 250 GB SATA, 2.5“<br />

32 GB SATA solid-state drive in<br />

single-level cell architecture<br />

5/82<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>627C<br />

Flash drive 1 x CompactFlash drive on front<br />

1 x internal CompactFlash drive,<br />

optional<br />

Optical drives DVD+/-RW/DL SATA, optional<br />

(depth is increased from <strong>80</strong> mm to<br />

100 mm)<br />

Interfaces<br />

PROFINET 3 x RJ45 (CP 1616-compatible,<br />

optional)<br />

Note:<br />

The PROFINET options are<br />

supplied with 2 MB battery-backed<br />

SRAM.<br />

PROFIBUS/MPI 12 Mbit/s (isolated, CP 5611compatible,<br />

optional)<br />

Note:<br />

The PROFIBUS/MPI options are<br />

supplied with 2 MB battery-backed<br />

SRAM.<br />

Ethernet 2 x 10/100/1000 Mbit/s<br />

(RJ 45, teaming capability)<br />

USB 4 x USB 2.0 (high current),<br />

high-speed<br />

Serial 1 x COM1<br />

Parallel Multi_IO-<strong>PC</strong>I module (available as<br />

accessory)<br />

DVI-I 1 x (analog, digital)<br />

VGA Via adapter cable, DVI-I to VGA<br />

adapter<br />

(available as accessory)<br />

Dual Monitor Via adapter cable, DVI-I to VGA &<br />

DVI<br />

(available as accessory)<br />

Monitoring functions<br />

Temperature Overshoot/undershoot of permissible<br />

operating temperature<br />

range<br />

Outdoor temperature<br />

Messages can be evaluated by<br />

the application program<br />

Watchdog Monitoring of program execution<br />

Monitoring time can be parameterized<br />

in software<br />

Restart can be parameterized in<br />

the event of a fault<br />

Messages can be evaluated by<br />

the application program<br />

Fan Speed monitoring<br />

Local displays Port <strong>80</strong> display:<br />

Two 7-segment displays for<br />

monitoring the <strong>PC</strong> power-up<br />

(freely programmable)<br />

Two 2-color LEDs for status<br />

outputs<br />

(freely programmable)


■ Technical specifications (continued)<br />

Monitoring functions via the<br />

network<br />

SIMATIC I<strong>PC</strong>627C<br />

SIMATIC I<strong>PC</strong> DiagMonitor<br />

(optional)<br />

Remote monitoring capability for:<br />

Watchdog<br />

Temperature<br />

Fan speed<br />

Hard disk monitoring (SMART)<br />

Operating hours counter<br />

Communication:<br />

Internet (Web server)<br />

Ethernet interface (SNMP<br />

protocol)<br />

O<strong>PC</strong> for integration in SIMATIC<br />

software<br />

Structure of client/server<br />

architectures<br />

Structure of log files<br />

Long-term recording of<br />

measured data (temperature, fan)<br />

and graphic display<br />

Ambient conditions<br />

Degree of protection (front/rear) IP20 according to EN 60529<br />

Ambient temperature during With maximum configuration:<br />

operation<br />

5 to 45 °C<br />

5 to 50 °C (up to 20 W load on <strong>PC</strong>I<br />

bus)<br />

5 to 55 °C (up to 10 W load on <strong>PC</strong>I<br />

bus)<br />

Vibration<br />

During operation 10 to 58 Hz: 0.75 mm;<br />

58 to 500 Hz: 9.8 m/s2 (approx. 1 g)<br />

With DVD operation:<br />

10 to 58 Hz: 0.018 mm;<br />

58 to 500 Hz: 2.5 m/s2 (approx.<br />

0.25 g)<br />

Note:<br />

No vibration permitted when<br />

burning DVDs<br />

Storage/transport 5 ... 9 Hz: 3.5 mm, 9 ... 500 Hz:<br />

9.8 m/s2 Shock<br />

During operation 50 m/s2 With DVD operation:<br />

50m/s2 , 11 ms (approx. 5 g)<br />

Note:<br />

No shock permitted when burning<br />

DVDs<br />

Storage/transport 250 m/s2 , 6 ms<br />

Relative humidity<br />

During operation 5% to <strong>80</strong>% at 25 °C<br />

(no condensation)<br />

5% to 95% at 25 °C<br />

(no condensation)<br />

Storage/transport<br />

Protection class Protection class I acc. to VDE 0106<br />

Part 1 (IEC 536)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>627C<br />

Electromagnetic compatibility<br />

(EMC)<br />

Emitted interference EN 55022 Class B<br />

Immunity to conducted interference<br />

on the supply lines<br />

Immunity to interference on signal<br />

lines<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>627C<br />

±2 kV (IEC 61000-4-4, burst)<br />

±1 kV (IEC 61000-4-5, symm.<br />

surge)<br />

±2 kV (IEC 61000-4-5, asymm.<br />

surge)<br />

±1 kV (IEC 61000-4-4, burst,<br />

length < 3 m)<br />

±2 kV (IEC 61000-4-4, burst,<br />

length > 3 m)<br />

±2 kV (IEC 61000-4-5, surge,<br />

length > 30 m)<br />

Immunity to static discharge ±6 kV, contact discharge<br />

(IEC 61000-4-2)<br />

±8 kV, air discharge<br />

(IEC 61000-4-2)<br />

Immunity to high radio frequency<br />

interference<br />

10 V/m, <strong>80</strong> ... 1000 MHz<br />

<strong>80</strong>% AM (according to<br />

IEC 61000-4-3)<br />

10 V/m, 1.4 ... 2.0 GHz, 50%<br />

duty cycle (according to<br />

IEC 61000-4-3)<br />

10 V <strong>80</strong>% AM, 9 KHz ... 8 MHz<br />

(according to IEC 61000-4-6)<br />

Immunity to magnetic fields 100 A/m, 50 MHz (IEC 61000-4-6)<br />

Software<br />

System-tested SIMATIC Industrial <strong>ST</strong>EP 7<br />

Software<br />

WinAC<br />

ProTool/Pro<br />

WinCC<br />

SOFTNET<br />

Note:<br />

Compliance with system configuration<br />

rules is essential<br />

Approvals<br />

Safety regulations IEC 60950-1<br />

Approvals cULus508, cULus1950,<br />

FCC Class A<br />

CE mark Use in industry:<br />

Emitted interference:<br />

EN 61000-6-4:2001<br />

Noise immunity:<br />

EN 61000-6:2001<br />

Application in residential areas,<br />

business and trade environments<br />

as well as in workshops:<br />

Emitted interference:<br />

EN 61000-6-1, 2001<br />

Noise immunity:<br />

EN 61000-6-1:2000<br />

Other standards:<br />

EN 61000-3-2-2000<br />

(harmonic currents)<br />

EN 61000-3-3:1995 (voltage<br />

fluctuations and flicker)<br />

5/83<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>627C<br />

■ Technical specifications (continued)<br />

SIMATIC I<strong>PC</strong>627C<br />

Dimensions<br />

Equipment dimensions W x H x D 298 x 301 (incl. mounting rail)<br />

(in mm)<br />

x 100<br />

Without DVD drive W x H x D 298 x 301 (incl. mounting rail)<br />

(in mm)<br />

x <strong>80</strong><br />

Weight Approx. 7 kg<br />

Miscellaneous<br />

Battery-backed SRAM 2 MB onboard<br />

(in the case of motherboard with<br />

PROFIBUS/PROFINET version)<br />

CMOS battery Service-friendly, simple<br />

replacement from outside,<br />

warning for timely replacement<br />

DiagBase diagnostics software Software for local <strong>PC</strong> diagnostics<br />

(temperature, battery, HDD, …)<br />

Interface module <strong>PC</strong>I interface card for COM2, LPT<br />

(accessory)<br />

Portrait mounting Accessories for particularly<br />

space-saving <strong>PC</strong> installation in<br />

control cabinets:<br />

Assembly kit for interface outlet<br />

on front<br />

Assembly kit for interface outlet<br />

on top or bottom<br />

1) Suitable for specific LINUX versions in accordance with the specifications<br />

of the <strong>Siemens</strong> manufacturer's declaration "Suited for LINUX",<br />

see www.siemens.com/simatic-pc/suited-for-linux<br />

(LINUX is a trademark of Linus Torvald).<br />

5/84<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>627C<br />

Component sticker Sticker on enclosure for identifying<br />

the <strong>PC</strong> components (processor,<br />

HDD, MAC addresses, ...)<br />

Fan For active device heat dissipation<br />

1 x enclosure<br />

1 x power supply<br />

This is a prerequisite for the flexible<br />

installation options<br />

Mounting positions 5 installation options underline the<br />

flexibility<br />

Cable grips 1 x for 100/240 V AC / 24 V DC<br />

supply cable<br />

1 x for all USB and Ethernet<br />

interfaces<br />

(LAN FastConnect connectors<br />

are supported)<br />

1 x for PROFINET


<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>627C<br />

■ Ordering data Order No. Order No.<br />

Configuration 1)<br />

1<br />

Configuration<br />

SIMATIC I<strong>PC</strong>627C D 6ES7 647 - 16 C 777 - 7 7 7 7<br />

HD graphics onboard, 128 MB<br />

dyn. shared memory;<br />

2 x 10/100/1000 Mbit/s Ethernet<br />

RJ45; 4 x USB V2.0 (high<br />

current); 1 x serial (COM1),<br />

RAID controller onboard;<br />

CompactFlash drive No. 1 at front<br />

(without CF); watchdog, temp./fan<br />

monitoring;<br />

Processor/motherboard:<br />

Celeron P4505<br />

(2C/2T, 1.86 GHz, 2 MB cache)<br />

Celeron P4505 (2C/2T,<br />

1.86 GHz, 2 MB cache),<br />

A<br />

B<br />

PROFIBUS/MPI, 2 MB batterybacked<br />

SRAM<br />

Celeron P4505 (2C/2T, 1.86<br />

GHz, 2 MB cache), PROFINET<br />

(3 x RJ45, CP 1616-compatible),<br />

C<br />

2 MB battery-backed SRAM<br />

Core i3-330E (2C/4T, 2.13 GHz,<br />

D<br />

HT, VT, 3 MB cache)<br />

Core i3-330E (2C/4T, 2.13 GHz,<br />

HT, VT, 3 MB cache),<br />

E<br />

PROFIBUS/MPI, 2 MB batterybacked<br />

SRAM<br />

Core i3-330E (2C/4T, 2.13 GHz,<br />

HT, VT, 3 MB cache), PROFINET<br />

(3 x RJ45, CP 1616-compatible),<br />

F<br />

2 MB battery-backed SRAM<br />

Core i7-610E (2C/4T, 2.53 GHz,<br />

G<br />

TB, HT, VT, AMT, 4 MB cache)<br />

Core i7-610E (2C/4T, 2.53 GHz,<br />

H<br />

TB, HT, VT, AMT, 4 MB cache),<br />

PROFIBUS/MPI, 2 MB batterybacked<br />

SRAM<br />

Core i7-610E (2C/4T, 2.53 GHz,<br />

TB, HT, VT, AMT, 4 MB cache),<br />

J<br />

PROFINET (3 x RJ45, CP 1616compatible),<br />

2 MB batterybacked<br />

SRAM<br />

Memory expansion<br />

1 GB DDR3 1066, DIMM 0<br />

2 GB DDR3 1066 DIMM 1<br />

3 GB DDR3 1066 DIMM 2<br />

4 GB DDR3 1066 DIMM 3<br />

2 GB DDR3 1066 DIMM, ECC 5<br />

4 GB DDR3 1066 DIMM, ECC 6<br />

Country-specific version/power<br />

supply<br />

100/240 V AC industrial power<br />

0<br />

supply with Namur; European<br />

cable<br />

100/240 V AC industrial power<br />

1<br />

supply with Namur; UK cable<br />

100/240 V AC industrial power<br />

2<br />

supply with Namur; CH cable<br />

1)<br />

1<br />

SIMATIC I<strong>PC</strong>627C D 6ES7 647 - 16 C 7 7 7 - 7 777<br />

Country-specific version/power<br />

supply<br />

(continued)<br />

100/240 V AC industrial power<br />

supply with Namur; USA cable<br />

3<br />

100/240 V AC industrial power<br />

supply with Namur; Italian cable<br />

100/240 V AC industrial power<br />

supply with Namur; Chinese<br />

4<br />

5<br />

cable<br />

24 V DC industrial power supply<br />

<strong>PC</strong> slots<br />

6<br />

2 x <strong>PC</strong>I free 0<br />

1 x <strong>PC</strong>I, 1x <strong>PC</strong>Ie (x16) free<br />

Drives<br />

1<br />

250 GB HDD SATA A<br />

250 GB HDD SATA; DVD+/-RW B<br />

500 GB HDD SATA C<br />

500 GB HDD SATA; DVD+/-RW D<br />

2 x 250 GB SATA (2.5")<br />

2 x 250 GB SATA (2.5") +<br />

DVD+/-RW<br />

RAID1 2 x 250 GB SATA (2.5")<br />

E<br />

F<br />

G<br />

RAID1 2 x 250 GB SATA (2.5");<br />

H<br />

DVD+/-RW<br />

32 GB SATA solid state drive<br />

J<br />

(SLC)<br />

32 GB SATA solid state drive<br />

(SLC); DVD+/-RW<br />

CompactFlash drive No. 2<br />

installed, DVD+/-RW<br />

K<br />

U<br />

CompactFlash drive No. 2<br />

V<br />

installed<br />

DVD+/-RW W<br />

Without drives X<br />

Operating system<br />

(preinstalled and activated)<br />

Windows XP Professional MUI,<br />

A<br />

SP3 (Eng, Ger, Fr, It, Sp)<br />

Windows 7 Ultimate, MUI<br />

(Eng, Ger, Fr, It, Sp)<br />

B<br />

Windows Embedded Standard<br />

F<br />

2009 English on 8 GB<br />

CompactFlash<br />

Without operating system X<br />

Expansion<br />

No expansion (software) 0<br />

SIMATIC I<strong>PC</strong> DiagMonitor<br />

1<br />

software included<br />

SIMATIC I<strong>PC</strong> Image&Partition<br />

Creator software included<br />

2<br />

SIMATIC I<strong>PC</strong> DiagMonitor,<br />

Image & Partition Creator<br />

software included<br />

3<br />

1) For an up-to-date overview, see the SIMATIC <strong>PC</strong> online configurator<br />

at: www.siemens.com/ipc-configurator<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

5/85<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>627C<br />

■ Ordering data Order No. Order No.<br />

Accessories<br />

Expansion components<br />

Memory expansions<br />

SIMATIC <strong>PC</strong> keyboard 6ES7 648-0CB00-0YA0<br />

1 GB DDR3 1066, DIMM A 6ES7 648-2AJ40-0KA0<br />

German/international, USB<br />

1 GB DDR3 1066 DIMM; ECC A 6ES7 648-2AJ40-1KA0<br />

connection<br />

2 GB DDR3 1066, DIMM A 6ES7 648-2AJ50-0KA0<br />

SIMATIC <strong>PC</strong> mouse A 6ES7 790-0AA01-0XA0<br />

2 GB DDR3 1066, DIMM; ECC A 6ES7 648-2AJ50-1KA0<br />

(optical, 3-button); for PG and <strong>PC</strong><br />

with adapter<br />

4 GB DDR3 1066, DIMM A 6ES7 648-2AJ60-0KA0<br />

CompactFlash card<br />

4 GB DDR3 1066, DIMM; ECC A 6ES7 648-2AJ60-1KA0<br />

Compact Flash, 4 GB, Industrial A 6ES7 648-2BF02-0XG0<br />

<strong>PC</strong>I expansion card<br />

A 6ES7 648-2CA01-0AA0<br />

Grade - DIAG<br />

with COM1 and LPT<br />

Compact Flash, 8 GB, Industrial A 6ES7 648-2BF02-0XH0<br />

Graphic adapter cable<br />

Grade - DIAG<br />

DVI-I acc. to VGA, 250 mm long 6ES7 648-3AB00-0XA0<br />

SIMATIC I<strong>PC</strong> USB FlashDrive A 6ES7 648-0DC50-0AA0<br />

DVI-I acc. to VGA and DVI-D,<br />

250 mm long (Y cable)<br />

6ES7 648-3AE00-0XA0<br />

8 GB, USB 2.0, metal enclosure,<br />

bootable<br />

Portrait assembly kit<br />

SIMATIC I<strong>PC</strong> Service USB B 6AV7 672-8JD01-0AA0<br />

Interfaces upward/downward<br />

Interfaces to the front A<br />

6ES7 648-1AA10-0YA0<br />

6ES7 648-1AA10-0YB0<br />

FlashDrive<br />

8 GB, USB 2.0, metal enclosure,<br />

bootable, with BIOS-Manager,<br />

SIMATIC <strong>PC</strong>, 230 V AC power<br />

cable<br />

Image & Partition Creator preinstalled,<br />

incl. CD<br />

angled, 3 m for Box <strong>PC</strong> and Panel<br />

Communication products see expansion components<br />

<strong>PC</strong> for<br />

Power supply units and UPS see expansion components<br />

Austria, Belgium, Finland,<br />

France, Germany, Netherlands,<br />

Spain, Sweden<br />

6ES7 900-1AA00-0XA0<br />

RMOS3 real-time operating<br />

system<br />

see expansion components<br />

United Kingdom 6ES7 900-1BA00-0XA0<br />

Switzerland 6ES7 900-1CA00-0XA0<br />

USA 6ES7 900-1DA00-0XA0<br />

Italy 6ES7 900-1EA00-0XA0<br />

China 6ES7 900-1FA00-0XA0<br />

Note:<br />

Software Packages with SIMATIC WinCC flexible, SIMATIC WinCC and<br />

SIMATIC WinAC RTX (F) can be ordered together with the SIMATIC I<strong>PC</strong><br />

with a price advantage.<br />

More information under "Embedded Bundles / Packages for<br />

industrial <strong>PC</strong>s".<br />

5/86<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S


■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical<br />

specifications.<br />

78.5<br />

99.1<br />

3.6 295.2<br />

3.9<br />

265<br />

272.8<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

99.8<br />

11.2<br />

G_<strong>ST</strong><strong>80</strong>_XX_00457<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

■ More information<br />

Further information can be found on the Internet at:<br />

www.siemens.com/simatic-pc<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>627C<br />

5/87<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>827C<br />

■ Overview<br />

The SIMATIC I<strong>PC</strong>827C Box <strong>PC</strong> is a rugged and flexibly<br />

expandable control cabinet <strong>PC</strong> for machine-level usage in<br />

24-hour continuous operation at ambient temperatures<br />

of up to 55 °C.<br />

It offers:<br />

maximum performance and high expandability<br />

with Intel Core i technology<br />

5/88<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Maximum system performance for complex measuring,<br />

control and visualization tasks<br />

Intel processors: Core i7, Core i3 or Celeron; in each case with<br />

2 cores, with turbo-boost technology and AMT (i7) and hyperthreading<br />

(i7, i3)<br />

Intel BD82QM57 Platform Controller Hub (<strong>PC</strong>H)<br />

DDR3 1066 memory technology up to 8 GB RAM<br />

Intel HD Graphics Media Accelerator for significantly<br />

increased graphic performance<br />

<strong>PC</strong>I Express x16 slot for x16 graphic card support<br />

SATA hard disks with up to 500 GB capacity and NCQ<br />

technology (Native Command Queuing) for high-speed<br />

processing of large data volumes<br />

High flexibility and expandability<br />

Flexible installation in many different positions with mounting<br />

brackets or portrait assembly kit<br />

Vacant expansion slots: 3 x <strong>PC</strong>I, 1 x <strong>PC</strong>Ie Express (x16) and<br />

1 x <strong>PC</strong>Ie (x4)<br />

3 x PROFINET interfaces onboard (optional, IRT-capable,<br />

3-port, switching-enabled, CP 1616-compatible)<br />

1 x PROFIBUS interface onboard (optional,<br />

CP 5611-compatible)<br />

RAID1 controller onboard (no occupation of a <strong>PC</strong> slot)<br />

2 x LAN 10/100/1000 Mbit/s connections (Gbit LAN with<br />

teaming capability), PROFINET RT-compatible<br />

4 x high-speed USB 2.0 ports<br />

DVI-I interface (for VGA and/or DVI-D monitors)<br />

Rugged design for direct installation in the machine<br />

Maximum processor performance up to an ambient<br />

temperature of 55 °C<br />

High shock/vibration resistance in all possible mounting<br />

positions<br />

High EMC for safe operation<br />

SATA Solid State Drive (SSD) with 32 GB in Single Level Cell<br />

architecture (SLC) for high reliability and speed<br />

1 x CompactFlash drive externally accessible<br />

Strain relief for all cables/connectors


■ Benefits (continued)<br />

High system availability, fast startup, maintenance and<br />

servicing<br />

High degree of data security thanks to mirror disk system<br />

(RAID1, optional) or Solid State Drive (SSD, optional)<br />

RAM with ECC (optional) for increased data security:<br />

1-bit memory errors are corrected automatically<br />

2 MB battery-backed SRAM, of which 128 KB can be used as<br />

memory for retentive WinAC RTX data<br />

Active Management Technology (Intel AMT) for Core i7<br />

versions (remote access to the device, also in shut-down<br />

state)<br />

Externally accessible CMOS backup battery, replaceable<br />

during operation, status can be scanned by software<br />

Two 7-segment displays and 2 signal LEDs (two-color) for<br />

diagnostics purposes, freely programmable<br />

Operating system preinstalled, ready to run, and already<br />

activated (eliminates need for usual product activation via the<br />

Internet or by telephone)<br />

Following system failure, fast restoration of hard disk contents<br />

to factory status using supplied recovery and restore DVD<br />

Worldwide service and support<br />

Cost reductions through high investment security<br />

Long-term platform with Intel embedded components<br />

Availability of 3 to 5 years, then guaranteed availability of<br />

spare parts for further 5 years<br />

Part of the scalable Box <strong>PC</strong> range with identical performance<br />

features and footprint<br />

System-tested with SIMATIC hardware and software<br />

Certification for worldwide marketing (e. g.: cULus)<br />

Installation compatible for all device generations, software<br />

compatible with predecessor model<br />

■ Application<br />

The SIMATIC I<strong>PC</strong>827C provides mechanical engineers, plant<br />

engineers, and control cabinet makers with a high-performance,<br />

compact <strong>PC</strong> platform for application at the machine or in the<br />

industrial environment for:<br />

Measuring and controlling of process and machine data<br />

(e. g. automated washing systems, robot controls)<br />

Operating and visualization tasks with separate display/<br />

monitor solutions (e. g. information terminals, large-scale<br />

displays in automotive production)<br />

Data acquisition and processing (e. g. production data<br />

acquisition, distributed process control)<br />

The SIMATIC I<strong>PC</strong>827C has CE certification for use in the industrial<br />

sector as well as in residential and commercial areas, and<br />

small businesses. In addition to industrial applications, it can<br />

also be used in building services automation or in facilities open<br />

to the public.<br />

The SIMATIC Box <strong>PC</strong>s can be ordered in combination with<br />

WinCC flexible or WinCC as SIMATIC HMI packages at a<br />

reduced price.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Design<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>827C<br />

Basic equipment<br />

Rugged metal installation housing, resistant to vibrations and<br />

shocks, with high electromagnetic compatibility<br />

Card retainer for reliable operation of <strong>PC</strong> modules in the event<br />

of vibrations and shocks<br />

Vibration and shock-absorbing hard disk holder<br />

Graphics onboard 1600 x 1200, 85 Hz, 32-bit colors<br />

Vacant slots: 2 x <strong>PC</strong>I 290 mm, 1 x <strong>PC</strong>I 240 mm,<br />

1 x <strong>PC</strong>Ie x16 240 mm, and 1 x <strong>PC</strong>Ie x4 185 mm<br />

Interfaces (accessible from one side):<br />

- 2 x LAN 10/100/1000 Mbit/s Ethernet interface (RJ45)<br />

- DVI-I graphic interface<br />

- 4 x USB 2.0<br />

- 1 x serial (COM1)<br />

- CompactFlash drive (external operation possible)<br />

- Two 7-segment displays (port <strong>80</strong>) and two 2-color signal<br />

LEDs for status display (freely programmable)<br />

Design versions<br />

Processor:<br />

- Intel Core i7-610E processor (2C/4T, 2.53 GHz, TB, HT, VT,<br />

AMT, 4 MB cache)<br />

- Intel Core i3-330E processor (2C/4T, 2.13 GHz, HT, VT,<br />

3 MB cache)<br />

- Intel Celeron P4505 processor (2C/2T, 1.86 GHz,<br />

2 MB cache)<br />

Main memory:<br />

- 1 GB to 4 GB, DDR3 1066<br />

- ECC memory 2 GB / 4 GB, DDR3 1066<br />

Fieldbus:<br />

- PROFINET onboard, IRT-capable, switching-enabled,<br />

3 x RJ45, CP 1616-compatible, PROFINET versions feature<br />

2 MB battery-backed SRAM onboard<br />

- PROFIBUS/MPI onboard, CP 5611-compatible, PROFIBUS<br />

versions feature 2 MB battery-backed SRAM onboard<br />

Drives:<br />

- SATA hard disks: 250/500 GB, 3.5";<br />

RAID1 2 x 250 GB, 2.5"<br />

- Solid State Drive (SSD) SATA 32 GB in Single Level Cell<br />

architecture (SLC)<br />

- Optical drive SATA DVD+/-RW/-RAM/-DL<br />

Power supply:<br />

- 100 / 240 V AC (wide range), 50/60 Hz<br />

- 24 V DC industrial power supply<br />

Preinstalled operating systems:<br />

- Windows XP Professional, multi language<br />

- Windows 7 Ultimate, multi language<br />

- Windows Embedded Standard 2009 English (XP-based, on<br />

8GB CompactFlash)<br />

SIMATIC I<strong>PC</strong> DiagMonitor 1)<br />

SIMATIC I<strong>PC</strong> Image & Partition Creator software 1)<br />

1) Further information can be found under "Expansion components/<br />

accessories".<br />

5/89<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>827C<br />

■ Function<br />

Integrated, parameterizable monitoring functions (program<br />

execution (watchdog), internal enclosure temperature,<br />

external enclosure temperature, speed monitoring of fans,<br />

CMOS battery)<br />

Expanded diagnostics/signaling via Ethernet, e-mail, text<br />

message, and for direct infeed to SIMATIC software via O<strong>PC</strong><br />

and logging (optional using SIMATIC I<strong>PC</strong> DiagMonitor):<br />

- Operating hours counter<br />

- Hard disk status<br />

- Automatic logging of all messages to a log file<br />

- Long-term recording and graphic display of measured<br />

values (temperature, fan)<br />

- Option for remote monitoring of networked SIMATIC I<strong>PC</strong>s<br />

RAID1 for automatic data mirroring on two serial ATA hard<br />

disks<br />

FlashDrive, via externally accessible CompactFlash card or<br />

Solid State Drive for extremely rugged data storage or the<br />

design of systems without hard disk<br />

AMT functionality (Intel Active Management Technology).<br />

This feature allows remote access to the I<strong>PC</strong> (for service work)<br />

even with operating system shut down, e. g.:<br />

- Starting up/shutting down the I<strong>PC</strong><br />

- BIOS update<br />

CMOS batteries are externally accessible and therefore easily<br />

replaced<br />

Flash BIOS with the ability to store customer-specific CMOS<br />

settings in a non-volatile memory area<br />

The PROFINET and PROFIBUS versions offer 2 MB of batterybacked<br />

SRAM for application data<br />

After an unexpected power interruption, up to 128 KB of<br />

important process data can be written into the battery-backed<br />

SRAM<br />

Two 7-segment displays (port <strong>80</strong>) for power-up display and for<br />

customer outputs (freely programmable)<br />

Two 2-color LEDs (green/red) for display of status messages<br />

(freely programmable)<br />

5/90<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Integration<br />

Integrated interfaces:<br />

Ethernet<br />

Two integrated Ethernet interfaces (10/100/1000 Mbit/s) for<br />

IT communication and for exchanging data with automation<br />

devices such as SIMATIC S7 (with the software package<br />

"SOFTNET S7").<br />

PROFINET<br />

The optional PROFINET interface for connecting distributed<br />

field devices or for controlling drives.<br />

PROFIBUS<br />

The optional floating PROFIBUS interface (12 Mbit/s) can be<br />

used to connect distributed field devices or for the interface to<br />

SIMATIC S7 (with the "SOFTNET for PROFIBUS" software<br />

packages).<br />

Further interfaces<br />

There are two free slots for <strong>PC</strong> modules, 4 USB (Universal<br />

Serial Bus) and a serial interface for connecting additional I/O<br />

devices.


■ Technical specifications<br />

SIMATIC I<strong>PC</strong>827C<br />

General features<br />

Design Rack-mountable, wall or portrait<br />

mounting<br />

Processor Intel Core i7-620E processor<br />

(2C/4T, 2.53 GHz, 4 MB L2, turbo<br />

boost, VT-d, AMT);<br />

Intel Core i3-330E processor<br />

(2C/4T, 2.13 GHz, 3 MB L2)<br />

Intel Celeron P4505 processor<br />

(2C/2T, 1.86 GHz, 2 MB L2)<br />

Chipset Intel Platform Controller Hub<br />

BD82QM57<br />

Main memory 1 GB; DDR3 1066, DIMM<br />

expandable up to 4 GB<br />

(2 memory bases)<br />

ECC memory 2/4 GB optional<br />

Free slots for expansions 2 x <strong>PC</strong>I 290 mm,<br />

1 x <strong>PC</strong>I 240 mm,<br />

1 x <strong>PC</strong>Ie x16 240 mm and<br />

1 x <strong>PC</strong>Ie x4 185 mm<br />

Graphics Onboard, Intel HD graphics,<br />

256 MB (dynamic shared<br />

memory),<br />

VGA: 1600 x 1200 / 32 bit colors /<br />

85 Hz,<br />

DVI-I: 1600 x 1200 / 32 bit colors /<br />

60 Hz,<br />

LCD: 12<strong>80</strong> x 1024 / 18 bit<br />

Operating system Without operating system<br />

Preinstalled, activated, and<br />

supplied on restore DVD:<br />

XP Prof. MUI, SP3;<br />

Windows 7 Ultimate MUI,<br />

Windows Embedded Standard<br />

2009 English on 8 GB Compact-<br />

Flash (XP-based)<br />

MUI: Multi User Interface;<br />

5 languages (English, French,<br />

German, Italian, Spanish)<br />

RMOS3 (separately orderable)<br />

Project-specific on request:<br />

Linux 1)<br />

Other<br />

Power supply 100/240 V AC, 190 W;<br />

wide range; with short-term<br />

bridging of power failures in<br />

accordance with NAMUR: max.<br />

20 ms at 93 V or 264 V<br />

50 to 60 Hz (47 to 63 Hz)<br />

24 V DC, 210 W isolated<br />

(optional)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>827C<br />

SIMATIC I<strong>PC</strong>827C<br />

Drives<br />

Hard disk without<br />

250 GB SATA, 3.5"<br />

500 GB SATA, 3.5"<br />

2 x 250 GB SATA, 2.5"<br />

RAID1, 2 x 250 GB SATA, 2.5"<br />

Solid State Drive (SSD) 32 GB SATA 2.5" in Single Level<br />

Cell architecture (SLC)<br />

FlashDrive CompactFlash drive at front<br />

Optical drives SATA-DVD+/-RW/DL, optional<br />

(depth is increased from 155 mm<br />

to 175 mm)<br />

Interfaces<br />

PROFINET 3 x RJ45 (CP 1616-compatible,<br />

optional)<br />

Note:<br />

The PROFINET options are<br />

supplied with 2 MB battery-backed<br />

SRAM.<br />

PROFIBUS/MPI 12 Mbit/s (isolated,<br />

CP 5611-compatible, optional)<br />

Note:<br />

The PROFIBUS/MPI options are<br />

supplied with 2 MB battery-backed<br />

SRAM.<br />

Ethernet 2 x 10/100/1000 Mbit/s<br />

(RJ 45, teaming-capable)<br />

USB 4 x USB 2.0 (high current),<br />

high-speed<br />

Serial 1 x COM1<br />

Parallel Multi IO <strong>PC</strong>I module<br />

(available as accessory)<br />

DVI-I 1 x (analog, digital)<br />

VGA Via adapter cable, DVI-I to VGA<br />

adapter<br />

(available as accessory)<br />

Dual monitor Via adapter cable, DVI-I to VGA &<br />

DVI<br />

(available as accessory)<br />

Monitoring functions<br />

Temperature Overshoot/undershoot of permissible<br />

operating temperature<br />

range<br />

Outdoor temperature<br />

Messages can be evaluated by<br />

the application program<br />

Watchdog Monitoring of program execution<br />

Monitoring time can be parameterized<br />

in software<br />

Restart can be parameterized in<br />

the event of a fault<br />

Messages can be evaluated by<br />

the application program<br />

5/91<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>827C<br />

■ Technical specifications (continued)<br />

Monitoring functions<br />

(continued)<br />

Fan Speed monitoring<br />

Local displays Port <strong>80</strong> display:<br />

Two 7-segment displays for<br />

monitoring the <strong>PC</strong> power-up<br />

(freely programmable)<br />

Two 2-color LEDs for status<br />

outputs (freely programmable)<br />

Monitoring functions via the<br />

network<br />

5/92<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>827C<br />

SIMATIC I<strong>PC</strong> DiagMonitor<br />

(optional)<br />

Remote monitoring capability for:<br />

Watchdog<br />

Temperature<br />

Fan speed<br />

Hard disk monitoring (SMART)<br />

Operating hours counter<br />

Communication:<br />

Internet (Web server)<br />

Ethernet interface (SNMP<br />

protocol)<br />

O<strong>PC</strong> for integration in SIMATIC<br />

software<br />

Structure of client/server<br />

architectures<br />

Structure of log files<br />

Long-term recording of<br />

measured data (temperature, fan)<br />

and graphic display<br />

Ambient conditions<br />

Degree of protection IP 20 to EN 60529<br />

Ambient temperature during With maximum configuration:<br />

operation<br />

5 to 45 °C<br />

5 to 50 °C (up to 50 W load on<br />

<strong>PC</strong>I(e) bus)<br />

5 to 55 °C (up to 10 W load on<br />

<strong>PC</strong>I(e) bus)<br />

Vibration<br />

During operation 10 to 58 Hz: 0.75 mm;<br />

58 to 500 Hz: 9.8 m/s2 (approx. 1 g)<br />

With DVD operation:<br />

10 to 58 Hz: 0.018 mm;<br />

58 to 500 Hz: 2.5 m/s2 (approx. 0.25 g)<br />

Note:<br />

No vibration permitted when<br />

burning DVDs<br />

During storage/transport 5 ... 9 Hz: 3.5 mm, 9 ... 500 Hz:<br />

9.8 m/s2 Shock<br />

During operation 50 m/s2 With DVD operation:<br />

50m/s2 , 11 ms (approx. 5 g)<br />

Note:<br />

No shock permitted when burning<br />

DVDs<br />

During storage/transport 250 m/s2 , 6 ms<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>827C<br />

Relative humidity<br />

During operation 5 ... <strong>80</strong>% at 25 °C<br />

(no condensation)<br />

During storage/transport 5 ... 95% at 25 °C<br />

(no condensation)<br />

Electromagnetic compatibility<br />

(EMC)<br />

Emitted interference EN 55022 Class B<br />

Immunity to conducted interference<br />

on the supply lines<br />

Immunity to interference on<br />

signal lines<br />

±2 kV (IEC 61000-4-4, burst)<br />

±1 kV (IEC 61000-4-5, symm.<br />

surge)<br />

±2 kV (IEC 61000-4-5, asymm.<br />

surge)<br />

±1 kV (IEC 61000-4-4, burst,<br />

length < 3 m)<br />

±2 kV (IEC 61000-4-4, burst,<br />

length > 3 m)<br />

±2 kV (IEC 61000-4-5, surge,<br />

length > 30 m)<br />

Immunity to static discharge ±6 kV, contact discharge<br />

(IEC 61000-4-2)<br />

±8 kV, air discharge<br />

(IEC 61000-4-2)<br />

Immunity to high radio frequency<br />

interference<br />

10 V/m, <strong>80</strong> ... 1000 MHz, <strong>80</strong>% AM<br />

(according to IEC 61000-4-3)<br />

10 V/m, 1.4 ... 2.0 GHz, 50%<br />

duty cycle (according to<br />

IEC 61000-4-3)<br />

10 V <strong>80</strong>% AM, 9 kHz ... 8 MHz<br />

(according to IEC 61000-4-6)<br />

Immunity to magnetic fields 100 A/m, 50 MHz (IEC 61000-4-6)<br />

Software<br />

System-tested SIMATIC industrial <strong>ST</strong>EP 7<br />

software<br />

WinAC<br />

WinCC<br />

SOFTNET<br />

Note:<br />

Compliance with system configuration<br />

rules is essential.<br />

Approvals<br />

Safety regulations IEC 60950-1<br />

Approvals cULus508, cULus1950, FCC<br />

Class A<br />

CE mark Use in industry:<br />

Emitted interference:<br />

EN 61000-6-4:2001<br />

Noise immunity:<br />

EN 61000-6:2001<br />

Application in residential areas,<br />

business and trade environments<br />

as well as in workshops:<br />

Emitted interference:<br />

EN 61000-6-1, 2001<br />

Noise immunity:<br />

EN 61000-6-1:2000<br />

Other standards:<br />

EN 61000-3-2-2000<br />

(harmonic currents)<br />

EN 61000-3-3:1995<br />

(voltage fluctuations and flicker)


■ Technical specifications (continued)<br />

Dimensions<br />

Device dimensions (W x H x D)<br />

in mm<br />

SIMATIC I<strong>PC</strong>827C<br />

298 x 301 (incl. mounting rail)<br />

x 175<br />

Without DVD drive in mm 298 x 301 (incl. mounting rail)<br />

x 155<br />

Weight Approx. 9 kg<br />

Miscellaneous<br />

Battery-backed SRAM 2 MB onboard<br />

(in the case of motherboard with<br />

PROFIBUS/PROFINET version)<br />

CMOS battery Service-friendly, simple<br />

replacement from outside,<br />

warning for timely replacement<br />

DiagBase diagnostics software Software for local <strong>PC</strong> diagnostics<br />

(temperature, battery, HDD, …)<br />

Interface module <strong>PC</strong>I interface card for COM2,<br />

LPT (accessory)<br />

Portrait mounting Accessories for particularly<br />

space-saving <strong>PC</strong> installation in<br />

control cabinets:<br />

Mounting kit for interface outlet at<br />

front,<br />

mounting kit for interface outlet up<br />

or down<br />

1) Note: The PROFINET/PROFIBUS options are supplied with 2 MB<br />

battery-backed SRAM<br />

2) No vibration permitted when burning DVDs;<br />

3) No shock permitted when burning DVDs<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>827C<br />

SIMATIC I<strong>PC</strong>827C<br />

Component sticker Sticker on enclosure for identifying<br />

the<br />

<strong>PC</strong> components (processor, HDD,<br />

MAC addresses, ...)<br />

Fan For active device heat dissipation<br />

1 x enclosure<br />

1 x power supply<br />

This is a prerequisite for the flexible<br />

installation options<br />

Mounting positions 5 installation options underline the<br />

flexibility<br />

Cable grips 1 x for 100/240 V AC / 24 V DC<br />

supply cable<br />

1 x for all USB and Ethernet<br />

interfaces<br />

(LAN FastConnect connectors<br />

are supported)<br />

1 x for PROFINET<br />

5/93<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>827C<br />

■ Ordering data Order No. Order No.<br />

Configuration<br />

1<br />

SIMATIC I<strong>PC</strong>827C<br />

Processor:<br />

D 6ES7 647 - 16 P 777 - 7 7 7 7<br />

Celeron P 4505 (2C/2T,<br />

1.86 GHz, 2 MB cache)<br />

A<br />

Celeron P 4505 (2C/2T,<br />

1.86 GHz, 2 MB cache);<br />

PROFIBUS/MPI; 2 MB batterybacked<br />

SRAM<br />

B<br />

Celeron P 4505 (2C/2T,<br />

1.86 GHz, 2 MB cache);<br />

PROFINET (3 x RJ45,<br />

CP 1616-compatible);<br />

2 MB battery-backed SRAM<br />

C<br />

Core i3-330E (2C/4T, 2.13 GHz,<br />

HT, VT, 3 MB cache)<br />

D<br />

Core i3-330E (2.13 GHz, HT, VT,<br />

3 MB cache); PROFIBUS/MPI;<br />

2 MB battery-backed SRAM<br />

E<br />

Core i3-330 (2C/4T, 2.13 GHz,<br />

HT, VT, 3 MB cache);<br />

PROFINET (3 x RJ45,<br />

CP 1616-compatible);<br />

2 MB battery-backed SRAM<br />

F<br />

Core i7-610E (2C/4T, 2.53 GHz,<br />

TB, HT, VT, AMT, 4 MB cache)<br />

G<br />

Core i7-610E (2C/4T, 2.53 GHz,<br />

TB, HT, VT, AMT, 4 MB cache);<br />

PROFIBUS/MPI; 2 MB batterybacked<br />

SRAM<br />

H<br />

Core i7-610E (2C/4T, 2.53 GHz,<br />

TB, HT, VT, AMT, 4 MB cache);<br />

PROFINET (3 x RJ45,<br />

CP 1616-compatible);<br />

2 MB battery-backed SRAM<br />

Memory expansion:<br />

J<br />

1 GB DDR3 1066 DIMM 0<br />

2 GB DDR3 1066 DIMM 1<br />

3 GB DDR3 1066 DIMM 2<br />

4 GB DDR3 1066 DIMM 3<br />

2 GB DDR3 1066 DIMM, ECC 5<br />

4 GB DDR3 1066 DIMM, ECC<br />

Power supply<br />

6<br />

100/240 V AC industrial power<br />

supply with Namur; European<br />

cable<br />

0<br />

100/240 V AC industrial power<br />

supply with Namur; UK cable<br />

1<br />

100/240 V AC industrial power<br />

supply with Namur; Swiss cable<br />

2<br />

100/240 V AC industrial power<br />

supply with Namur; USA cable<br />

3<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

5/94<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Configuration<br />

1<br />

SIMATIC I<strong>PC</strong>827C<br />

Power supply<br />

(continued)<br />

D 6ES7 647 - 16 P 7 7 7 - 7 777<br />

100/240 V AC industrial power<br />

supply with Namur; Italian cable<br />

4<br />

100/240 V AC industrial power<br />

supply with Namur; Chinese<br />

cable<br />

5<br />

24 V DC industrial power supply<br />

Expansions (HW)<br />

6<br />

3x <strong>PC</strong>I, 2x <strong>PC</strong>Ie (x4), 1x <strong>PC</strong>Ie<br />

(x16) vacant<br />

Mass storage<br />

0<br />

250 GB HDD SATA A<br />

250 GB HDD SATA; DVD+/-RW B<br />

500 GB HDD SATA C<br />

500 GB HDD SATA; DVD+/-RW D<br />

2x 250 GB SATA (2.5") E<br />

2x 250 GB SATA (2.5");<br />

DVD+/-RW<br />

F<br />

RAID1 2x 250 GB SATA (2.5") G<br />

RAID1 2x 250 GB SATA (2.5");<br />

DVD+/-RW<br />

H<br />

Solid State Drive 32 GB (SLC) J<br />

Solid State Drive 32 GB (SLC);<br />

DVD+/-RW<br />

K<br />

DVD+/-RW W<br />

Without drives<br />

Operating system (preinstalled<br />

and activated)<br />

X<br />

Windows XP Prof. MUI, SP3<br />

(English, German, French,<br />

Italian, Spanish),<br />

A<br />

Windows 7 Ultimate MUI<br />

(English, German, French,<br />

Italian, Spanish),<br />

B<br />

Windows XP Embedded<br />

Standard 2009 English on 8 GB<br />

CompactFlash<br />

F<br />

Without operating system<br />

Expansion software<br />

X<br />

No expansion (software) 0<br />

SIMATIC I<strong>PC</strong> DiagMonitor<br />

software included<br />

1<br />

SIMATIC I<strong>PC</strong> Image&Partition<br />

Creator included<br />

4<br />

SIMATIC I<strong>PC</strong> DiagMonitor &<br />

Image&Partition Creator<br />

included<br />

5<br />

Note:<br />

Windows Embedded only without RAID option


<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>827C<br />

■ Ordering data Order No. Order No.<br />

Accessories<br />

Expansion components<br />

Memory expansions<br />

SIMATIC <strong>PC</strong> keyboard 6ES7 648-0CB00-0YA0<br />

1 GB DDR3 1066 DIMM<br />

1 GB DDR3 1066 DIMM, ECC<br />

2 GB DDR3 1066 DIMM<br />

A<br />

A<br />

A<br />

6ES7 648-2AJ40-0KA0<br />

6ES7 648-2AJ40-1KA0<br />

6ES7 648-2AJ50-0KA0<br />

German/international, USB port<br />

SIMATIC <strong>PC</strong> mouse A 6ES7 790-0AA01-0XA0<br />

2 GB DDR3 1066 DIMM, ECC<br />

4 GB DDR3 1066 DIMM<br />

A<br />

A<br />

6ES7 648-2AJ50-1KA0<br />

6ES7 648-2AJ60-0KA0<br />

(optical, 3-button) for PG and <strong>PC</strong><br />

with adapter<br />

4 GB DDR3 1066 DIMM, ECC A 6ES7 648-2AJ60-1KA0<br />

CompactFlash card<br />

<strong>PC</strong>I expansion card with COM1 A<br />

and LPT<br />

Graphic adapter cable<br />

DVI-I acc. to VGA, 250 mm long<br />

DVI-I acc. to VGA and DVI-D,<br />

250 mm long (Y cable)<br />

Portrait assembly kit<br />

Interfaces upward/downward A<br />

Interfaces to the front A<br />

Power cable<br />

6ES7 648-2CA01-0AA0<br />

6ES7 648-3AB00-0XA0<br />

6ES7 648-3AE00-0XA0<br />

6ES7 648-1AA30-0YA0<br />

6ES7 648-1AA30-0YB0<br />

CompactFlash, 4 GB, industrial A<br />

grade - DIAG<br />

CompactFlash, 8 GB, industrial A<br />

grade - DIAG<br />

SIMATIC I<strong>PC</strong> USB FlashDrive A<br />

8 GB, USB 2.0, metal enclosure,<br />

bootable<br />

SIMATIC I<strong>PC</strong> Service USB B<br />

FlashDrive<br />

8 GB, USB 2.0, metal enclosure,<br />

bootable, with BIOS Manager,<br />

6ES7 648-2BF02-0XG0<br />

6ES7 648-2BF02-0XH0<br />

6ES7 648-0DC50-0AA0<br />

6AV7 672-8JD01-0AA0<br />

SIMATIC <strong>PC</strong>, power cable for<br />

230 V AC, angled, 3 m for Box <strong>PC</strong><br />

Image & Partition Creator readyinstalled,<br />

incl. CD<br />

and Panel <strong>PC</strong> for<br />

Germany, France, Spain,<br />

Netherlands, Belgium, Sweden,<br />

Austria, Finland<br />

6ES7 900-1AA00-0XA0<br />

Communication products<br />

For power supplies and uninterruptible<br />

power supplies<br />

see expansion components<br />

see expansion components<br />

United Kingdom 6ES7 900-1BA00-0XA0<br />

RMOS3 real-time operating see expansion components<br />

Switzerland 6ES7 900-1CA00-0XA0<br />

system<br />

USA 6ES7 900-1DA00-0XA0<br />

Italy 6ES7 900-1EA00-0XA0<br />

China 6ES7 900-1FA00-0XA0<br />

Note:<br />

Software Packages with SIMATIC WinCC flexible, SIMATIC WinCC and<br />

SIMATIC WinAC RTX (F) can be ordered together with the SIMATIC I<strong>PC</strong><br />

with a price advantage.<br />

More information under "Embedded Bundles / Packages for<br />

industrial <strong>PC</strong>s".<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

5/95<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>827C<br />

■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical<br />

specifications.<br />

5/96<br />

173.2<br />

269.8<br />

3<br />

2.4<br />

265<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

297.2<br />

295.2<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

11<br />

G_<strong>ST</strong><strong>80</strong>_XX_00458<br />

■ More information<br />

Further information can be found on the Internet at:<br />

www.siemens.com/simatic-pc


■ Overview<br />

The SIMATIC Box <strong>PC</strong> 827B is a control cabinet <strong>PC</strong> for highperformance<br />

<strong>PC</strong> applications at machine level.<br />

It offers:<br />

maximum performance with a high degree of flexibility<br />

Intel Core2 Duo technology<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

SIMATIC Box <strong>PC</strong> 827B<br />

Maximum system performance for complex measuring,<br />

control and visualization tasks<br />

Intel processors: Core2 Duo or Celeron M<br />

Intel chipset: 945GM Express + ICH7R<br />

Intel GMA 950 graphics media accelerator<br />

<strong>PC</strong>I Express technology<br />

DDR2 667 memory technology up to 4 GB<br />

SATA hard disks up to 500 GB<br />

High flexibility and expandability<br />

Flexible installation in many different positions with mounting<br />

brackets or portrait installation kit<br />

Onboard: PROFINET or PROFIBUS interface and RAID1<br />

controller (optional)<br />

4 x <strong>PC</strong>I and 1 x <strong>PC</strong>Ie-Express (x4) or 2 x <strong>PC</strong>I and 3 x <strong>PC</strong>Ie (x4)<br />

2 x LAN 10/100/1000 Mbit/s connections (Gbit LAN with<br />

teaming capability)<br />

4 x high-speed USB-2.0 ports<br />

Rugged design for direct installation in the machine<br />

Maximum processor performance up to ambient temperature<br />

of 55 °C<br />

High shock/vibration resistance in all possible mounting<br />

positions<br />

High EMC for safe operation<br />

2 x CompactFlash drives, both accessible from the outside<br />

(one of which is optional)<br />

High system availability, fast startup, maintenance and<br />

servicing<br />

High degree of data security thanks to mirror disk system<br />

(RAID1, optional)<br />

Battery-backed SRAM as memory for WinAC data<br />

(with 24 V DC industrial power supply)<br />

All interfaces and control/display elements on one side to<br />

allow optimum installation in control cabinet<br />

2 x 7-segment display and 2 x two-color signal LEDs<br />

(freely programmable) for diagnostics purposes<br />

CMOS battery compartment accessible from outside<br />

Operating system preinstalled, ready to run, and already<br />

activated (eliminates need for usual product activation via the<br />

Internet or by telephone)<br />

Fast restoration of delivery state of hard disk contents with<br />

recovery and restore CDs<br />

Worldwide service and support<br />

Cost reductions through high investment security<br />

Long-term platform with embedded Intel components<br />

Availability of 3 to 5 years, guaranteed availability of spare<br />

parts for 5 years<br />

Part of the scalable Box-<strong>PC</strong> range with identical performance<br />

features and footprint<br />

System-tested with SIMATIC hardware and software<br />

Certification for worldwide marketing (cULus)<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/97<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

SIMATIC Box <strong>PC</strong> 827B<br />

■ Application<br />

The SIMATIC Box <strong>PC</strong> 827B provides mechanical engineers,<br />

plant engineers, and control cabinet makers with a high-performance,<br />

compact <strong>PC</strong> platform for application at the machine or<br />

in the industrial environment for:<br />

Measuring, testing, open-loop and closed-loop control of<br />

process and machine data (e. g. filling plants, packaging<br />

machines, machines for the semiconductor industry, CD/DVD<br />

production machines)<br />

Operating and visualization tasks with separate display/<br />

monitor solutions (e. g. information terminals, large-scale<br />

displays in automotive production)<br />

Data acquisition and processing (e. g. wind-driven power<br />

stations, energy management, test systems)<br />

The SIMATIC Box <strong>PC</strong> 827B has CE certification for use in the<br />

industrial sector as well as in residential and commercial areas,<br />

and small businesses. In addition to industrial applications, it<br />

can also be used in building services automation or in facilities<br />

open to the public.<br />

The SIMATIC Box <strong>PC</strong>s can be ordered in combination with<br />

WinCC flexible or WinCC as SIMATIC HMI packages at a<br />

reduced price.<br />

■ Design<br />

Basic design<br />

Rugged metal enclosure, resistant to vibration and shock, with<br />

high electromagnetic compatibility<br />

Card retainer for reliable operation of <strong>PC</strong> modules in the event<br />

of vibration and shock<br />

Graphics onboard 1600 x 1200, 85 Hz, 32-bit colors<br />

Interfaces (accessible from one side):<br />

- 2 x LAN 10/100/1000 Mbit/s Ethernet interface<br />

(RJ45, teaming-capable)<br />

- DVI-I graphic interface<br />

-4x USB2.0<br />

- 1 x serial (COM1)<br />

CompactFlash drive (can be plugged in from outside)<br />

Two 7-segment displays and two two-color LEDs for status<br />

indication (freely programmable)<br />

5/98<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Design versions<br />

Processor:<br />

- Intel Celeron M 440 1.86 GHz, 533 MHz FSB, 1 MB L2 cache<br />

- Intel Core2 Duo T5500 1.66 GHz, 677 MHz FSB,<br />

2 MB L2 cache<br />

- Intel Core2 Duo T7400 2.16 GHz, 677 MHz FSB,<br />

4 MB L2 cache<br />

Main memory expansion from 256 MB to 4 GB, DDR2 677<br />

Fieldbus:<br />

- PROFINET onboard, 3 x RJ45, CP 1616-compatible,<br />

PROFINET versions feature 2 MB battery-backed SRAM<br />

onboard<br />

- PROFIBUS/MPI onboard, CP 5611-compatible, PROFIBUS<br />

versions feature 2 MB SRAM with battery back-up onboard<br />

Drives:<br />

- Hard disks Serial ATA<br />

160 GB, 3.5"<br />

250/500 GB, 3.5"<br />

RAID1, 2 x 250 GB, 2.5"<br />

- Optical drives DVD+/-RW/-RAM/-DL<br />

- CompactFlash drive (internal) instead of HDD, ODD<br />

Spare slots for expansion:<br />

- 1 x <strong>PC</strong>I-Express x4 (175 mm) and 4 x <strong>PC</strong>I (265 mm)<br />

- 1 x <strong>PC</strong>I-Express x4 (175 mm), 2 x <strong>PC</strong>I-Express x4 and<br />

2 x <strong>PC</strong>I (265 mm)<br />

Power supply:<br />

- 110/230 V AC (autorange), 50/60 Hz<br />

- 24 V DC industrial power supply<br />

Preinstalled and activated operating systems<br />

- Windows 2000 Professional, multi language<br />

- Windows XP Professional, multi language<br />

- Windows XP Embedded English (on 2 GB CompactFlash)<br />

- Windows Vista Ultimate, Multi Language<br />

SIMATIC <strong>PC</strong> DiagMonitor 1)<br />

SIMATIC <strong>PC</strong>/PG Image Creator 1)<br />

1) Further information can be found under "Expansion components".


© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

SIMATIC Box <strong>PC</strong> 827B<br />

■ Function<br />

■ Technical specifications<br />

Integrated and configurable monitoring functions (program<br />

execution (watchdog)), internal enclosure temperature,<br />

external enclosure temperature, fan speed monitoring)<br />

General features<br />

SIMATIC Box <strong>PC</strong> 827B<br />

Extended diagnostics/alarms via Ethernet, e-mail, text<br />

message and for direct infeed into the SIMATIC software via<br />

Design Rack-mountable, wall or portrait<br />

mounting<br />

O<strong>PC</strong> and logging (optionally via SIMATIC I<strong>PC</strong> DiagMonitor): Processor Intel Core2 Duo 7400, 2.16 GHz,<br />

- Runtime meter<br />

- Hard disk status<br />

- Automatic logging of all alarms by means of a log file<br />

- Long-term recording and graphic display of measured<br />

values (temperature, fan)<br />

- Capability for central monitoring of networked SIMATIC <strong>PC</strong>s<br />

677 MHz FSB,<br />

4 MB L2 cache<br />

Intel Core2 Duo 5500, 1.66 GHz,<br />

677 MHz FSB,<br />

2 MB L2 cache<br />

Intel Celeron M 440 1.86 GHz,<br />

533 MHz FSB, 1 MB L2 cache<br />

RAID1 for automatic data mirroring on two serial ATA hard<br />

disks<br />

2 x CompactFlash drive, can be accessed externally, for<br />

extremely rugged data storage and for configuring systems<br />

without hard disks<br />

Externally accessible CMOS battery supports easy battery<br />

Chipset<br />

Main memory<br />

Free slots for expansions<br />

Intel 945 GM Express<br />

256 MB; DDR2 677, SODIMM;<br />

expandable up to 4 GB<br />

(2 memory bases)<br />

1 x <strong>PC</strong>I-Express x4 (175 mm)<br />

and 4 x <strong>PC</strong>I (265 mm)<br />

replacement<br />

1 x <strong>PC</strong>I-Express x4 (175 mm),<br />

Flash BIOS with capability for saving customer-specific CMOS<br />

settings in a non-volatile memory area<br />

The PROFINET and PROFIBUS versions offer 2 MB of batterybacked<br />

SRAM for application data<br />

Graphics<br />

2 x <strong>PC</strong>I-Express x4 and 2 x <strong>PC</strong>I<br />

(265 mm)<br />

Onboard, Intel GMA 950 graphics<br />

controller<br />

8 ... 128 MB SDRAM (dynamic<br />

When using the DC power supply, important process data can<br />

still be written into the battery-backed SRAM following an<br />

unforeseen power interruption<br />

Two 7-segment displays (Port <strong>80</strong>) for the power-up display<br />

shared memory)<br />

VGA: 1600 x 1200 /<br />

32-bit colors / 85 Hz<br />

DVI-I: 1600 x 1200 /<br />

32-bit colors / 60 Hz<br />

and for customer outputs (user-programmable)<br />

LCD: 12<strong>80</strong> x 1024 / 18-bit<br />

Two 2-color LEDs (green/red) for the indication of status Operating system Without<br />

messages (user-programmable)<br />

All interfaces and control elements on one side permit simple<br />

installation of the <strong>PC</strong> in a control cabinet<br />

■ Integration<br />

Preinstalled and activated, and<br />

supplied on restore DVD:<br />

Windows 2000 Professional<br />

MUI<br />

Integrated interfaces:<br />

Ethernet<br />

Two integrated, teaming-capable Ethernet interfaces<br />

(10/100/1000 Mbit/s) can be used for IT communication and<br />

for data exchange with programmable controllers such as<br />

SIMATIC S7 (with the "SOFTNET S7" software packages).<br />

PROFINET<br />

The optional, isolated PROFINET interface can be used for<br />

connecting distributed field devices or for controlling drives.<br />

PROFIBUS<br />

The optional floating PROFIBUS interface (12 Mbit/s) can be<br />

used to connect distributed field devices or for the interface to<br />

SIMATIC S7 (with the "SOFTNET for PROFIBUS" software<br />

packages).<br />

Further interfaces<br />

For connecting additional I/O devices, 2 free slots are<br />

available for <strong>PC</strong> modules as well as 4 USB (Universal Serial<br />

Bus) interfaces and one serial interface.<br />

2) ; SP4<br />

Windows XP Professional MUI 2) ;<br />

SP2<br />

Windows Vista Ultimate MUI 2)<br />

Windows XP Embedded 3) 4)<br />

(SP2) English on 2 GB<br />

CompactFlash<br />

Order separately<br />

Project-specific on request<br />

RMOS3<br />

Linux 1)<br />

Other<br />

Power supply 100/240 V AC, 190 W;<br />

autorange; with short-term<br />

bridging of power failures in<br />

accordance with NAMUR: max.<br />

20 ms at 93 V or 264 V<br />

50to60Hz (47to63Hz)<br />

24 V DC, 210 W isolated<br />

(optional)<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/99<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

SIMATIC Box <strong>PC</strong> 827B<br />

■ Technical specifications (continued)<br />

Drives<br />

Hard disk without<br />

160 GB 3.5"<br />

250 GB 3.5"<br />

2 x 250 GB 2.5"<br />

RAID1, 2 x 250 GB 2.5"<br />

Flash drive CompactFlash drive No. 1<br />

at front<br />

CompactFlash drive No. 2 at<br />

front, instead of HDD, ODD<br />

DVD+/-RW Optional (depth is increased by<br />

20 mm)<br />

Interfaces<br />

PROFINET 3 x RJ45 (CP 1616-compatible,<br />

optional)<br />

Note<br />

The PROFINET options are<br />

supplied with 2 MB<br />

battery-backed SRAM.<br />

PROFIBUS/MPI 12 Mbit/s (isolated, compatible<br />

with CP 5611, optional)<br />

Note:<br />

The PROFIBUS/MPI options are<br />

supplied with 2 MB SRAM with<br />

battery back-up.<br />

Ethernet 2 x 10/100/1000 Mbit/s<br />

(RJ45, teaming-capable)<br />

USB 4 x USB 2.0 (high current),<br />

high-speed<br />

Serial 1 x COM1<br />

Parallel <strong>PC</strong>I interface module (optional)<br />

DVI-I 1 x (analog, digital)<br />

VGA Via DVI-I to VGA adapter<br />

(available as accessory)<br />

Monitoring functions<br />

Temperature Overshoot/undershoot of<br />

permissible operating temperature<br />

Outside temperature<br />

Messages can be evaluated by<br />

the application program<br />

Watchdog Monitoring of program execution<br />

Monitoring time can be parameterized<br />

in software<br />

Restart can be parameterized in<br />

the event of a fault<br />

Messages can be evaluated by<br />

the application program<br />

Fan Speed monitoring<br />

5/100<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC Box <strong>PC</strong> 827B<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC Box <strong>PC</strong> 827B<br />

Local displays Port <strong>80</strong> display:<br />

Two 7-segment displays for<br />

monitoring the <strong>PC</strong> power-up<br />

(user-programmable)<br />

Two 2-color LEDs for status<br />

outputs<br />

(user-programmable)<br />

Monitoring functions via the<br />

network<br />

SIMATIC <strong>PC</strong> DiagMonitor (optional)<br />

Remote monitoring capability for:<br />

Watchdog<br />

Temperature<br />

Fan speed<br />

Hard disk monitoring (SMART)<br />

Runtime meter<br />

Communication:<br />

Internet (Web server)<br />

Ethernet interface (SNMP<br />

protocol)<br />

O<strong>PC</strong> for integration in SIMATIC<br />

software<br />

Structure of client/server<br />

architectures<br />

Layout of log files<br />

Long-term recording of<br />

measured values (temperature,<br />

fan) and graphic display<br />

Ambient conditions<br />

Degree of protection (front/rear) IP20 to EN 60529<br />

Ambient temperature during<br />

operation<br />

With maximum configuration 5 ... 45 °C<br />

up to 50 W load on <strong>PC</strong>Ie bus 5...50°C<br />

up to 10 W load on <strong>PC</strong>Ie bus 5...55°C<br />

Vibration<br />

During operation 10 ... 58 Hz: 0.75 mm;<br />

58 ... 500 Hz: 9.8 m/s2 (approx. 1 g)<br />

With DVD operation:<br />

10 ... 58 Hz: 0.018 mm;<br />

58 ... 500 Hz: 2.5 m/s2 (approx. 0.25 g)<br />

Note:<br />

No vibration permitted when<br />

burning DVDs<br />

Storage/transport 5 ... 9 Hz: 3.5 mm, 9 ... 500 Hz:<br />

9.8 m/s2 Shock<br />

During operation 50 m/s2 With DVD operation:<br />

50 m/s2 , 11 ms (approx. 5 g)<br />

Note:<br />

No shock permitted when burning<br />

DVDs<br />

Storage/transport 250 m/s2 , 6 ms


■ Technical specifications (continued)<br />

Relative humidity<br />

During operation 5 ... <strong>80</strong>% at 25 °C<br />

(no condensation)<br />

Storage/transport 5 ... 95% at 25 °C<br />

(no condensation)<br />

Protection class Protection class I acc. to<br />

VDE 0106 Part 1 (IEC 536)<br />

Electromagnetic compatibility<br />

(EMC)<br />

Emitted interference EN 55022 Class B<br />

Noise immunity<br />

to conducted interference on the<br />

supply cables<br />

SIMATIC Box <strong>PC</strong> 827B<br />

± 2 kV (IEC 61000-4-4, burst)<br />

± 1 kV (IEC 61000-4-5, surge<br />

symm.)<br />

± 2 kV (IEC 61000-4-5, surge<br />

unsymm.)<br />

on signal cables ± 1 kV (IEC 61000-4-4, burst,<br />

length < 3 m)<br />

±2 kV (IEC 61000-4-4, burst,<br />

length > 3 m)<br />

±2 kV (IEC 61000-4-5, surge,<br />

length > 30 m)<br />

to static discharge ± 6 kV, contact discharge<br />

(IEC 61000-4-2)<br />

± 8 kV, air discharge<br />

(IEC 61000-4-2)<br />

to radiofrequency radiation 10 V/m, <strong>80</strong> to 1000 MHz, <strong>80</strong>% AM<br />

(according to IEC 61000-4-3)<br />

10 V/m, 1.4 to 2.0 GHz, 50% ED<br />

(according to IEC 61000-4-3)<br />

10 V <strong>80</strong>% AM, 9 KHz to 8 MHz<br />

(according to IEC 61000-4-6)<br />

to magnetic fields 100 A/m, 50 MHz (IEC 61000-4-6)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

System tested SIMATIC<br />

Industrial Software<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

SIMATIC Box <strong>PC</strong> 827B<br />

SIMATIC Box <strong>PC</strong> 827B<br />

<strong>ST</strong>EP 7<br />

WinAC<br />

ProTool/Pro<br />

WinCC<br />

SOFTNET<br />

Note:<br />

Compliance with system<br />

configuration rules is essential<br />

Approvals<br />

Safety regulations IEC 60950-1<br />

Approvals cULus508, cULus1950,<br />

FCC Class A<br />

CE mark<br />

Use in industrial environments Emitted interference:<br />

EN 61000-6-4:2001<br />

Noise immunity:<br />

EN 61000-6:2001<br />

Applications in residential areas, Emitted interference:<br />

business and trade environments, EN 61000-6-1, 2001<br />

as well as in small companies Noise immunity:<br />

EN 61000-6-1:2000<br />

Other standards EN 61000-3-2-2000<br />

(harmonic currents)<br />

EN 61000-3-3:1995<br />

(voltage variations and flicker)<br />

Dimensions<br />

Equipment dimensions (in mm) 298 x 301 (incl. mounting rail)<br />

x 175<br />

Without DVD drive 298 x 301 (incl. mounting rail)<br />

x 155<br />

Weight<br />

Weight, approx. 9 kg<br />

1) Suitable for specific LINUX versions in accordance with the specifications<br />

of the <strong>Siemens</strong> manufacturer's declaration "Suited for LINUX", see<br />

www.siemens.com/simatic-pc/suited-for-linux<br />

(LINUX is a trademark of Linus Torvald).<br />

2) MUI: Multi-user interface; 5 languages (English, French, German, Italian,<br />

Spanish)<br />

3) XPe and Vista require at least 512 MB of memory expansion<br />

4) XPe does not support RAID1 function<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/101<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

SIMATIC Box <strong>PC</strong> 827B<br />

■ Ordering data Order No. Order No.<br />

Configuration 1)<br />

1<br />

Configuration<br />

SIMATIC Box <strong>PC</strong> 827B D 6ES7 647 - 16 N 777 - 7 7 7 7<br />

1)<br />

1<br />

SIMATIC Box <strong>PC</strong> 827B D 6ES7 647 - 16 N 7 7 7 - 7 777<br />

Graphics onboard, 128 MB shared<br />

memory; 2 x 10/100/1000 Mbit/s<br />

Ethernet RJ45; 4 x USB V2.0 (high<br />

current); 1 x serial (COM1), RAID<br />

controller onboard; CompactFlash<br />

drive No. 1 at front; watchdog,<br />

temp./fan monitoring<br />

Processor<br />

Celeron M 440 (1.86 GHz, 1 MB<br />

A<br />

L2, 533 MHz FSB)<br />

Celeron M 440 (1.86 GHz, 1 MB<br />

B<br />

L2, 533 MHz FSB); PROFIBUS/<br />

MPI; 2 MB battery-backed<br />

SRAM<br />

Celeron M 440 (1.86 GHz, 1 MB<br />

C<br />

L2, 533 MHz FSB); PROFINET<br />

(3 x RJ45, CP 1616-compatible);<br />

2 MB battery-backed SRAM<br />

Core2 Duo T5500 (1.66 GHz,<br />

D<br />

2 MB L2, 667 MHz FSB);<br />

Core2 Duo T5500 (1.66 GHz,<br />

E<br />

2 MB L2, 667 MHz FSB);<br />

PROFIBUS/MPI; 2 MB batterybacked<br />

SRAM<br />

Core2 Duo T5500 (1.66 GHz,<br />

F<br />

2 MB L2, EM64-T); PROFINET<br />

(3 x RJ45, CP 1616-compatible);<br />

2 MB battery-backed SRAM<br />

Core2 Duo T7400 (2.16 GHz,<br />

G<br />

4 MB L2, 667 MHz FSB)<br />

Core2 Duo T7400 (2.16 GHz,<br />

H<br />

4 MB SLC, 667 MHz FSB);<br />

PROFIBUS/MPI; 2 MB batterybacked<br />

SRAM<br />

Core2 Duo T7400 (2.16 GHz,<br />

J<br />

4MB SLC, EM64-T, 667MHz<br />

FSB); PROFINET (3 x RJ45,<br />

CP 1616-compatible); 2 MB<br />

battery-backed SRAM<br />

Memory expansion<br />

256 MB DDR2 667 SODIMM 0<br />

512 MB DDR2 667 SODIMM 1<br />

1 GB DDR2 667 SODIMM 2<br />

2 GB DDR2 667 SODIMM 3<br />

3 GB DDR2 667 SODIMM 4<br />

4 GB DDR2 667 SODIMM 5<br />

Country-specific version/power<br />

supply<br />

110/230 V AC industrial power<br />

0<br />

supply with Namur; power cable<br />

for Europe<br />

110/230 V AC industrial power<br />

1<br />

supply Namur; power cable for<br />

United Kingdom<br />

110/230 V AC industrial power<br />

2<br />

supply Namur; power cable for<br />

Switzerland<br />

110/230 V AC industrial power<br />

3<br />

supply Namur; power cable for<br />

USA<br />

110/230 V AC industrial power<br />

4<br />

supply Namur; power cable for<br />

Italy<br />

110/230 V AC industrial power<br />

5<br />

supply with Namur; power cable<br />

for China<br />

24 V DC industrial power supply 6<br />

5/102<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Expansions (HW)<br />

4 x <strong>PC</strong>I, 1 x <strong>PC</strong>Ie (x4) free; 0<br />

2 x <strong>PC</strong>I, 3 x <strong>PC</strong>Ie (x4) free; 1<br />

<strong>PC</strong>I interface card with COM2,<br />

LPT1; 1 x <strong>PC</strong>I, 3 x <strong>PC</strong>Ie free;<br />

3<br />

<strong>PC</strong>I card with COM2, LPT1;<br />

3 x <strong>PC</strong>I, 1 x <strong>PC</strong>Ie free;<br />

Drives<br />

4<br />

160 GB HDD SATA A<br />

160 GB HDD SATA; DVD+/-RW B<br />

250 GB HDD SATA C<br />

250 GB HDD SATA; DVD+/-RW D<br />

2 x 250 GB SATA (2.5") E<br />

2 x 250 GB SATA (2.5");<br />

DVD+/-RW<br />

F<br />

RAID1 2 x 250 GB SATA (2.5") G<br />

RAID1 2 x 250 GB SATA (2.5");<br />

DVD+/-RW<br />

H<br />

CompactFlash drive No. 2 at<br />

front<br />

W<br />

Without drives<br />

Operating system<br />

(preinstalled and activated)<br />

Note:<br />

Windows XP Embedded: at least<br />

512 MB; do not select RAID1<br />

option;<br />

X<br />

Windows 2000 Prof. multi<br />

language SP4<br />

(Eng, Fr, Ger, It, Sp)<br />

D A<br />

Windows XP Prof. multi<br />

language SP2<br />

(Eng, Fr, Ger, It, Sp)<br />

D B<br />

Windows Vista Ultimate multi<br />

language (Eng, Ger, Fr, It, Sp);<br />

(at least 512 MB memory)<br />

C<br />

Windows XP Embedded (SP2)<br />

English on 2 GB CompactFlash;<br />

(at least 512 MB memory; no<br />

RAID1)<br />

F<br />

Without operating system<br />

Expansion software<br />

X<br />

Without expansion (software) 0<br />

SIMATIC I<strong>PC</strong> DiagMonitor<br />

software included<br />

1<br />

SIMATIC I<strong>PC</strong> Image&Partition<br />

Creator V3.0 included<br />

4<br />

SIMATIC I<strong>PC</strong> DiagMonitor &<br />

Image&Partition Creator V3.0<br />

included<br />

5<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

1) For an up-to-date overview, see the SIMATIC <strong>PC</strong> online configurator<br />

at: www.siemens.com/ipc-configurator


Note:<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

SIMATIC Box <strong>PC</strong> 827B<br />

■ Ordering data Order No. Order No.<br />

Accessories<br />

Expansion components<br />

Memory expansions<br />

SIMATIC <strong>PC</strong> keyboard 6ES7 648-0CB00-0YA0<br />

256 MB, DDR2 667, SODIMM<br />

512 MB, DDR2 667, SODIMM<br />

A<br />

A<br />

6ES7 648-2AG20-0HA0<br />

6ES7 648-2AG30-0HA0<br />

German/international, USB<br />

connection<br />

1 GB, DDR2 667, SODIMM<br />

2 GB, DDR2 667, SODIMM<br />

<strong>PC</strong>I expansion card<br />

A<br />

A<br />

A<br />

6ES7 648-2AG40-0HA0<br />

6ES7 648-2AG50-0HA0<br />

6ES7 648-2CA01-0AA0<br />

SIMATIC <strong>PC</strong> mouse A<br />

(optical, 3-button) for<br />

programming device and <strong>PC</strong> with<br />

6ES7 790-0AA01-0XA0<br />

with COM2 and LPT<br />

adapter<br />

Graphic adapter cable<br />

CompactFlash card<br />

DVI-I acc. to VGA, 250 mm long 6ES7 648-3AB00-0XA0<br />

2GB A 6ES7 648-2BF01-0XF0<br />

DVI-I acc. to VGA and DVI-D, 6ES7 648-3AE00-0XA0<br />

4GB A 6ES7 648-2BF01-0XG0<br />

250 mm long; (Y cable)<br />

SIMATIC I<strong>PC</strong> USB FlashDrive A 6ES7 648-0DC50-0AA0<br />

Portrait assembly kit<br />

Interfaces upward/downward A 6ES7 648-1AA30-0YA0<br />

8 GB, USB 2.0, metal enclosure,<br />

bootable<br />

Interfaces to the front A 6ES7 648-1AA30-0YB0<br />

SIMATIC I<strong>PC</strong> Service USB B 6AV7 672-8JD01-0AA0<br />

Power cable<br />

FlashDrive<br />

SIMATIC <strong>PC</strong>, power cable for<br />

8 GB, USB 2.0, metal enclosure,<br />

230 V AC, angled, 3 m for Box <strong>PC</strong><br />

bootable, with BIOS-Manager,<br />

and Panel <strong>PC</strong> for<br />

Image & Partition Creator pre-<br />

Austria, Belgium, Finland, 6ES7 900-1AA00-0XA0<br />

installed, incl. CD<br />

France, Germany, Netherlands,<br />

Spain, Sweden<br />

United Kingdom 6ES7 900-1BA00-0XA0<br />

Communication products<br />

Power supply units and UPS<br />

see expansion components<br />

see expansion components<br />

Switzerland 6ES7 900-1CA00-0XA0<br />

RMOS3 real-time operating see expansion components<br />

USA 6ES7 900-1DA00-0XA0<br />

system<br />

Italy 6ES7 900-1EA00-0XA0<br />

China 6ES7 900-1FA00-0XA0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

1) For an up-to-date overview, see the SIMATIC <strong>PC</strong> online configurator<br />

at: www.siemens.com/ipc-configurator<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Software Packages with SIMATIC WinCC flexible, SIMATIC<br />

WinCC and SIMATIC WinAC RTX (F) can be ordered together<br />

with the SIMATIC I<strong>PC</strong> with a price advantage.<br />

More information under "Embedded Bundles / Packages for<br />

industrial <strong>PC</strong>s".<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/103<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Box <strong>PC</strong><br />

SIMATIC Box <strong>PC</strong> 827B<br />

■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical<br />

specifications.<br />

5/104<br />

173.2<br />

269.8<br />

3<br />

2.4<br />

265<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

297.2<br />

295.2<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

11<br />

G_<strong>ST</strong><strong>80</strong>_XX_00458<br />

■ More information<br />

Further information can be found on the Internet at:<br />

www.siemens.com/simatic-pc


■ Overview<br />

SIMATIC Panel <strong>PC</strong>s are suitable thanks to their high industrial<br />

compatibility both for use in control cabinets, consoles and<br />

control panels, as well as directly on the machine. Typical areas<br />

of application can be found in both production and process<br />

automation.<br />

There is a broad range of robust, high-performance<br />

SIMATIC Panel <strong>PC</strong>s available for different requirements.<br />

Shared industrial functionality<br />

High-quality components and modules with a high MTBF<br />

(mean time between failure), which also ensure 24-hour<br />

operation in the extended temperature range<br />

High swing/shock capacity of the devices through special<br />

hard-disk suspensions, locked connectors and card retainers<br />

Rugged housing model with high electromagnetic<br />

compatibility (EMC) and integrated industrial power supplies<br />

(also as per NAMUR)<br />

Service-friendly device design<br />

Bright, brilliant displays in different sizes up to 19"<br />

Same front panel mounting dimensions and uniform front<br />

design across all device families<br />

Rugged fronts protected from dust, humidity and chemical<br />

substances (front-side IP65 / NEMA 4 degrees of protection)<br />

SIMATIC HMI I<strong>PC</strong>277D<br />

for implementing simple visualization and control tasks<br />

High degree of flexibility for selecting rugged widescreen<br />

fronts from 7" to 12" for a more freely configurable display area<br />

High resolution, large viewing angle, and up to 100%<br />

dimmable backlighting for a brilliant display with optimized<br />

power consumption<br />

Absolutely maintenance-free due to the use of CompactFlash<br />

and SSD as mass storage and fanless operation up to 50 °C<br />

ambient temperature<br />

Maximum industrial functionality due to non-volatile retentive<br />

memory<br />

Ready-to-use embedded bundles with visualization or/and<br />

control software<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>477C<br />

Ultra-compact and maintenance-free Panel <strong>PC</strong> in embedded<br />

technology<br />

Compact design (only 61 to 69 mm mounting depth for 12" to<br />

19" display)<br />

No rotating parts (without fan and hard disk)<br />

High security due to the Microsoft Windows Embedded<br />

Standard 2009 operating system<br />

Ready-to-use devices with optionally preinstalled software<br />

- HMI: Innovative HMI software WinCC flexible (incl. archives<br />

and recipes)<br />

- RTX: with real-time capable software PLC WinAC RTX<br />

Retentive memory on board (NV-RAM, usable with<br />

WinAC RTX)<br />

SIMATIC HMI I<strong>PC</strong>577C<br />

Industrial functionality and openness at an attractive price<br />

Full <strong>PC</strong> openness and performance boost with Intel Core2 Duo<br />

processors<br />

Rugged design for industrial use<br />

Can be expanded using a <strong>PC</strong>I slot and additional interfaces<br />

More rugged due to SSD (solid-state drive) or CompactFlash<br />

The configurator (best-fit for the customer) makes ordering<br />

more flexible<br />

Compact design<br />

SIMATIC HMI I<strong>PC</strong>677C<br />

Maximum performance, flexibility and availability<br />

Rugged, expandable industrial <strong>PC</strong> with different front panels<br />

Rugged design for industrial use<br />

Complete <strong>PC</strong> openness<br />

Optional PROFIBUS or PROFINET onboard<br />

All CPUs with dual core<br />

SIMATIC Panel <strong>PC</strong> 677B<br />

Flexibility and compactness with maximum performance<br />

Maximum performance thanks to latest process technology<br />

from Intel<br />

Dual Core technology: up to Intel Core2 Duo 2.16 GHz<br />

Compact structure with simultaneous expandability through<br />

<strong>PC</strong>I/<strong>PC</strong>Ie slots<br />

Strong communication through two Ethernet and integrated<br />

PROFIBUS DP/MPI interfaces<br />

Control and computer units can be separated by up to 30 m<br />

RAID1 controller on board<br />

Retentive memory on board (NV-RAM, usable with<br />

WinAC RTX)<br />

5/105<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC Panel <strong>PC</strong><br />

■ Overview (continued)<br />

SIMATIC HMI I<strong>PC</strong>277D SIMATIC HMI I<strong>PC</strong>477C SIMATIC HMI I<strong>PC</strong>577C SIMATIC HMI I<strong>PC</strong>677C<br />

Design<br />

Centralized configuration<br />

Distributed configuration<br />

(via remote kit)<br />

Display<br />

- - - -<br />

Size 7"/9"/12" widescreen 12"/15"/19" TFT 12"/15"/19" TFT 12"/15"/19" TFT<br />

Resolution <strong>80</strong>0 x 4<strong>80</strong>/<br />

<strong>80</strong>0 x 600/<br />

<strong>80</strong>0 x 600/<br />

<strong>80</strong>0 x 600/<br />

<strong>80</strong>0 x 4<strong>80</strong>/<br />

1024 x 768/<br />

1024 x 768/<br />

1024 x 768/<br />

Operator controls<br />

12<strong>80</strong> x <strong>80</strong>0<br />

12<strong>80</strong> x 1024<br />

12<strong>80</strong> x 1024<br />

12<strong>80</strong> x 1024<br />

Membrane keyboard<br />

Touch screen<br />

General features<br />

- 1) 1) 1)<br />

Power supply<br />

24 V DC / 110/240 V AC<br />

/- /- / /-/<br />

Processor Intel Atom E640, 1.0 GHz Intel Celeron M 1.2 GHz, Intel Celeron M 1.2 GHz, Intel Celeron P4505,<br />

Intel Core2 Solo 1.2 GHz Intel Core2 Solo 1.2 GHz 1.86 GHz, 2 cores,<br />

or<br />

or<br />

2 MB cache;<br />

Intel Core2 Duo 1.2 GHz Intel Core2 Duo 1.86 GHz Intel Core i3-330E,<br />

2.13 GHz, 2 cores,<br />

4 threads,<br />

3 MB cache, HT, VT-x;<br />

Intel Core i7-620E, 2.53<br />

GHz, 2 cores, 4 threads,<br />

4 MB, cache, TB, HT, VT-x,<br />

VT-d<br />

Main memory 1 GB 1 GB, 2 GB<br />

1 GB, 2 GB or 4 GB 1 GB expandable to 4 GB<br />

or 4 GB<br />

or 2 GB /4 GB with ECC<br />

Expansion slots 1 x CF slot for Compact- 1 x CF slot for Compact- 1 x <strong>PC</strong>I<br />

Flash Card (externally Flash Card (externally<br />

accessible)<br />

accessible)<br />

3) ; 1 x CF slot for 2 x <strong>PC</strong>I<br />

CompactFlash Card<br />

(externally accessible)<br />

2) or 1 x <strong>PC</strong>I and<br />

1 x <strong>PC</strong>Ie x16 Compact-<br />

Flash Card (externally<br />

accessible)<br />

Operating system None;<br />

Without;<br />

None;<br />

Without operating system,<br />

Windows Embedded Windows Embedded Windows Embedded 2009 Windows XP Professional<br />

Standard 2009 or XP 2009 or XP Professional or XP Professional MUI MUI, Windows 7 Ultimate<br />

Professional MUI MUI;<br />

MUI, Windows Embedded<br />

Interfaces<br />

Windows 7 Ultimate MUI<br />

or Windows Embedded<br />

Standard 7<br />

Standard 2009 on CF<br />

PROFIBUS/MPI -<br />

PROFINET (RT/IRT) / -<br />

Ethernet 2 x 10/100/1000 Mbit 10/100/1000 Mbit 10/100/1000 Mbit 10/100/1000 Mbit<br />

PS/2 (mouse/keyboard)<br />

USB<br />

Serial interface<br />

- - - -<br />

Parallel interface - - - -<br />

Audio in/out - - - -<br />

Graphic interface -<br />

5/106<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Overview (continued)<br />

Ambient conditions<br />

Available<br />

- Not available<br />

1) 12"/15" displays<br />

3) All slots with card retainer<br />

4) Valid with CF or SSD; with HDD: 5 g/0.5 g;<br />

5) 3 W taken into account for each <strong>PC</strong>I/<strong>PC</strong>Ie slot<br />

6) 15 W taken into account for each <strong>PC</strong>I/<strong>PC</strong>Ie slot<br />

7) 15 W taken into account for each <strong>PC</strong>I/<strong>PC</strong>Ie slot<br />

8) 0 °C to +50 °C; max. +50 °C in installation space; max. 40 °C if at the front<br />

Available<br />

- Not available<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

Vibration load during operation 1 g 1 g 4) 1 g<br />

1) 12"/15" displays<br />

2) With optional expansion rack<br />

3) All slots with card retainer<br />

4) With 19" Touch<br />

5) 15 W taken into account for each <strong>PC</strong>I/<strong>PC</strong>Ie slot<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>277D SIMATIC HMI I<strong>PC</strong>477C SIMATIC HMI I<strong>PC</strong>577C SIMATIC HMI I<strong>PC</strong>677C<br />

Shock loading during operation 5 g 5 g 4) 5 g<br />

Permissible temperature during<br />

operation with maximum configuration<br />

+0 °C … +50 °C +0 °C … +45 °C 8) +0 °C … +45 °C 8) +5 °C … +50 °C 8)<br />

Power loss in maximum<br />

configuration<br />

12" display 40 W 6) 55 W 7) 140 W 7)<br />

15" display 45 W 6) 57 W 7) 140 W 7)<br />

19" display 60 W 6) 84 W 7) 163 W 7)<br />

SIMATIC Panel <strong>PC</strong> 677B<br />

Design<br />

Centralized configuration<br />

Distributed configuration<br />

(via remote kit)<br />

2)<br />

Display<br />

Size 12”/15”/15” INOX/17”/19” TFT<br />

Resolution <strong>80</strong>0 x 600/<br />

1024 x 768/<br />

12<strong>80</strong> x 1024<br />

Operator controls<br />

Membrane keyboard 1)<br />

Touch screen<br />

General features<br />

Power supply<br />

/<br />

24 V DC / 110/230 V AC<br />

Processor Intel Celeron M 1.86 GHz;<br />

Intel<br />

Core2 Duo<br />

1.66 GHz;<br />

Intel Core2 Duo<br />

2.16 GHz<br />

Main memory 1GB;<br />

2 GB;<br />

3 GB;<br />

4 GB<br />

Expansion slots 2 x <strong>PC</strong>I or 1x <strong>PC</strong>I and<br />

1x <strong>PC</strong>Ie x4 3) ;<br />

1 x CF slot<br />

(externally accessible)<br />

Operating system Without;<br />

Windows 2000 Professional MUI;<br />

Windows XP Professional MUI;<br />

Windows Vista Ultimate MUI;<br />

Windows 2003 Standard Server;<br />

Windows XP embedded on CF<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Interfaces<br />

PROFIBUS/MPI<br />

PROFINET<br />

Ethernet 10/100/1000 Mbit<br />

PS/2 (mouse/keyboard) -<br />

USB<br />

Serial interface<br />

Parallel interface -<br />

Audio in/out -<br />

Graphic interface<br />

Ambient conditions<br />

Vibration load during operation 1 g<br />

Shock loading during operation 5 g<br />

Permissible temperature during +5 °C … +50 °C; max. 50 °C in<br />

operation with maximum configu- installation space, max. 40 °C at<br />

ration<br />

the front4) Power loss in maximum<br />

configuration<br />

12"/15" display 140 W 5)<br />

17"/19" display 163 W 5)<br />

SIMATIC Panel <strong>PC</strong> 677B<br />

5/107<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC Panel <strong>PC</strong><br />

■ Benefits<br />

■ More information<br />

High degree of industrial capability<br />

Additional information is available on the Internet at:<br />

The entire construction is designed for purely industrial use. www.siemens.com/simatic-panel-pc<br />

Thus, for example, a special vibration-absorbing suspension of<br />

the hard disk ensures operational reliability, even at high<br />

mechanical loads. SIMATIC Panel <strong>PC</strong>s are thus designed for a<br />

vibration load of 1 g (Panel <strong>PC</strong> 577B: 0.25 g) and a shock load<br />

of 5 g (Panel <strong>PC</strong> 577B: 1 g) during operation.<br />

Performance<br />

Thanks to the use of the latest Intel processors from ULV<br />

(Ultra Low Voltage) to Intel Core technology, SIMATIC Panel <strong>PC</strong>s<br />

are flexibly scalable for your application.<br />

Scalable computing power<br />

Highest computing power<br />

Latest Intel processor technology<br />

Dual Core, ULV, Atom<br />

Investment security<br />

High component continuity and guaranteed availability of spare<br />

parts for up to 5 years after product phase-out are ensured e. g.<br />

through the development and production of our own motherboards.<br />

This enables long-lasting machine concepts without<br />

renewed engineering effort.<br />

Service-friendly device design<br />

Upgrades and exchange of components are easy thanks to the<br />

device design.<br />

Integrated interfaces<br />

The different already-integrated interfaces allow various<br />

communication and expansion options. Many models are<br />

already equipped with Gigabit Ethernet and PROFIBUS DP/MPI<br />

interface.<br />

Extendibility<br />

Depending on the model, ISA, <strong>PC</strong>I, <strong>PC</strong>I Express, <strong>PC</strong>/104 Plus<br />

and <strong>PC</strong>/104 slots are available for individual expandability. This<br />

enables the further use of existing and new expansion cards.<br />

Compact dimensions<br />

Considering the desired expandability, SIMATIC Panel <strong>PC</strong>s have<br />

an extremely low mounting depth and can thus be used in very<br />

narrow installation locations.<br />

Options<br />

Various options enable an individual solution for your industrial<br />

application. Thus, the operator control unit can be operated<br />

separately from the computer unit by up to 30 m. The direct<br />

control key module increases the operating safety, as it can be<br />

used to run the process independently of the operating system<br />

and without delay directly on PROFIBUS DP/MPI.<br />

Individually expandable system availability<br />

RAID1 configuration - high system stability through redundant<br />

data management<br />

SIMATIC I<strong>PC</strong> DiagMonitor – Monitoring of the operating states<br />

and early detection of problems locally and in the network<br />

SIMATIC <strong>PC</strong>/PG Image & Partition Creator - downtime<br />

minimization through preventative data backup<br />

SITOP and Masterguard power supply (UPS) – Bridging of<br />

voltage dips<br />

5/108<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Overview<br />

SIMATIC HMI I<strong>PC</strong>277D for implementing simple visualization<br />

and control tasks<br />

Offers great flexibility in the selection of rugged widescreen<br />

fronts<br />

From 7" to 12" for more freely configurable display area<br />

High resolution, large viewing angle, and up to 100%<br />

dimmable backlighting for a brilliant display with optimized<br />

power consumption<br />

Absolutely maintenance-free due to the use of CompactFlash<br />

and SSD as mass storage and fanless operation up to 50 °C<br />

ambient temperature<br />

Maximum industrial functionality due to non-volatile retentive<br />

memory<br />

Ready-to-use embedded bundles with visualization or/and<br />

control software<br />

The following front installation versions are available:<br />

7" Touch<br />

9" Touch<br />

12" Touch<br />

15" / 19" available soon<br />

All fronts as widescreen version<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>227D<br />

SIMATIC HMI I<strong>PC</strong>277D<br />

Rugged, industry-standard widescreen displays (Touch) with<br />

7" / 9" / 12"<br />

- High resolution, 16 million colors, large viewing angle, can<br />

be dimmed from 0 to 100% (this also optimizes the power<br />

consumption)<br />

- Integrated front concept (Panel <strong>PC</strong>, Comfort Panels)<br />

- Fanless up to 50 °C ambient temp.<br />

- 15" / 19" with front USB interface available soon<br />

High-performance data processing at low power<br />

consumption<br />

Intel Atom technology of the Power-Optimized family E6xx<br />

Wake-on-LAN for remote-controlled switching between<br />

standby and active state<br />

Support of Sleep States/SpeedStep -> dynamic power<br />

adaptation depending on the required computing<br />

performance<br />

Intel VT-x technology for virtualization<br />

High degree of industrial functionality and flexibility for<br />

implementing the embedded solution<br />

Flexible memory concepts: CompactFlash or Solid-State Drive<br />

2 Gbit Ethernet (teaming-capable); PROFINET with<br />

RT functionality (via Standard Ethernet)<br />

3 high-speed USB 2.0 ports<br />

1 RS232<br />

Ready-to-run embedded bundles with WinAC RTX2010 (F)<br />

and/or WinCC RT Advanced (optional)<br />

512 KB retentive memory (MRAM), of which 128 KB can be<br />

written to within the buffer time (optional)<br />

High system availability in order to reduce the risk of<br />

potential failures and maintenance costs<br />

Maintenance-free since there are no rotating parts (fans, HDD)<br />

Battery-free operation even if retentive memory option is<br />

selected (with time-of-day synchronization via network)<br />

Comprehensive self-diagnostics thanks to pre-installed local<br />

diagnostic software SIMATIC I<strong>PC</strong> DiagBase<br />

High investment security in order to reduce engineering<br />

costs<br />

Long-term availability: Service & Support period of<br />

8 to10 years after market launch<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/109<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>227D<br />

■ Application<br />

The SIMATIC HMI I<strong>PC</strong>277D is a particularly compact and<br />

energy-saving Nanopanel <strong>PC</strong> with integrated touch displays<br />

with 7" screen diagonal or larger. The heart of the SIMATIC HMI<br />

I<strong>PC</strong>277D are high-performance Intel Atom processors of the<br />

latest generation. The Nanopanel <strong>PC</strong>s are designed for maintenance-free<br />

24-hour continuous use as well as for high temperature,<br />

vibration, shock and EMC requirements in the following<br />

applications:<br />

Simple visualization and control tasks, for example in<br />

mechanical engineering, plant construction, transportation<br />

systems or power transmission.<br />

Acquisition, further processing and visualization of data<br />

All machine-level applications created in C/C++ or with<br />

WinAC/WinCC RT Advanced that require rugged, compact<br />

I<strong>PC</strong>s<br />

Additional new applications such as shipbuilding, building<br />

automation, storage & logistics<br />

The application spectrum ranges from automation computers<br />

fully integrated in TIA with, for example, WinAC to C/C++-based<br />

automation solutions with the customer-specific operating<br />

systems. For software products that require Windows XP Professional,<br />

the combination of Windows XP Professional multi<br />

language is available preinstalled on the Solid-State Drive.<br />

The SIMATIC HMI I<strong>PC</strong>277D can be used in conjunction with<br />

WinCC RT Advanced and/or with WinAC RTX 2010/F as readyto-run<br />

bundle and is available at an attractive price.<br />

5/110<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Design<br />

The HMI I<strong>PC</strong>277D is a compact device comprising an operator<br />

control unit with integrated computer unit.<br />

Computing unit:<br />

Rugged metal enclosure, resistant to vibration and shock, with<br />

high electromagnetic compatibility<br />

Processor / main memory expansion:<br />

- Intel Atom E640 1.0 GHz, 1 GB RAM GHz<br />

- Intel Atom E660 1.3 GHz, 2 GB RAM GHz available soon<br />

Interfaces (accessible from one side):<br />

- 2 x LAN 10/100/1000 Mbit/s Ethernet interface (RJ45)<br />

- 3 x high-speed USB V2.0<br />

- 1 x COM1 (RS232)<br />

Fieldbus<br />

- PROFINET Realtime via Standard Ethernet interface<br />

Retentive memory<br />

- 512 KB retentive memory (MRAM), of which 128 KB within<br />

the buffer time (optional)<br />

Isolated power supply: 24 V DC (20.4 to 28.8 V)<br />

Drives:<br />

- CompactFlash drive (replaceable, accessible): 2 GB, 4 GB<br />

or 8 GB<br />

- Solid-State Drive 50 GB (SLC technology)<br />

Preinstalled operating systems:<br />

- Windows XP Embedded Standard 2009<br />

- Windows XP Professional multi language<br />

- Windows Embedded Standard 7 / Windows 7 available soon<br />

Components of the operator control unit:<br />

The operator control units are available in the following versions:<br />

7" Touch<br />

7" TFT color display, <strong>80</strong>0 x 4<strong>80</strong> pixels<br />

Resistive analog touch screen<br />

9" Touch<br />

9" TFT color display, <strong>80</strong>0 x 4<strong>80</strong> pixels<br />

Resistive analog touch screen<br />

12" Touch<br />

12" TFT color display, 12<strong>80</strong> x <strong>80</strong>0 pixels<br />

Resistive analog touch screen<br />

15" / 19" Touch available soon


■ Design (continued)<br />

SIMATIC HMI I<strong>PC</strong>277D bundles: HMI, RTX, RTX F and<br />

HMI/RTX<br />

HMI, RTX, RTX F and HMI/RTX complete turnkey solutions (the<br />

software is already preinstalled and configured) for visualization<br />

and automation in combination with WinCC RT Advanced and<br />

WinAC RTX 2010 (F).<br />

Quick start in automation solutions with Embedded<br />

Automation<br />

HMI: SIMATIC WinCC RT Advanced preinstalled and ready to<br />

run<br />

RTX: SIMATIC WinAC RTX 2010 preinstalled and ready to run<br />

RTX F: SIMATIC WinAC RTX 2010 F preinstalled and ready to<br />

run<br />

HMI/RTX (F): SIMATIC WinCC RT Advanced and SIMATIC<br />

WinAC RTX 2010(F) preinstalled and ready to run<br />

PROFINET (RT) pre-configured for use in a SIMATIC<br />

environment<br />

Configuration and programming with SIMATIC WinCC<br />

Engineering System and SIMATIC <strong>ST</strong>EP 7 via Industrial<br />

Ethernet<br />

Flexibility of a <strong>PC</strong>-based automation environment<br />

Open for additional <strong>PC</strong> applications<br />

Connection option for USB devices<br />

Use of WinAC ODK with SIMATIC WinAC RTX<br />

Data retentivity for WinAC RTX without uninterruptible power<br />

supply (UPS)<br />

Expansion components<br />

SIMATIC I<strong>PC</strong> DiagMonitor<br />

<strong>PC</strong> diagnostics/alarm software for early detection and<br />

diagnosis of <strong>PC</strong> problems<br />

Comprehensive monitoring of temperature, watchdog<br />

Operating hours counter for preventive maintenance<br />

Integrated log functions, comprehensive text messages,<br />

online help (English/German)<br />

Network-wide monitoring via SNMP and O<strong>PC</strong> interface<br />

possible<br />

SIMATIC I<strong>PC</strong> Image & Partition Creator<br />

Software tool for preventive data back-up of the contents of<br />

bulk storage (CF cards, SSD)<br />

High-speed restoring of system and data partitions with bit<br />

accuracy; user software and special installations are also<br />

backed up<br />

Software tool for adaptation of mass storage partitioning<br />

SIMATIC I<strong>PC</strong> Service USB FlashDrive<br />

Mobile memory medium for backing up/restoring mass<br />

memories<br />

Pre-installed Image & Partition Creator V3.1<br />

Ultra-compact and rugged<br />

Note:<br />

For further information, see "Expansion components".<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Function<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>227D<br />

Diagnosis<br />

DiagBase: Integrated, parameterizable monitoring functions<br />

(program execution/watchdog, internal enclosure<br />

temperature, DIAG bit for CF cards similar to S.M.A.R.T for<br />

hard disks)<br />

Expanded diagnostics/messages via Ethernet, e-mail, text<br />

message and for direct transfer to SIMATIC software via O<strong>PC</strong><br />

(optionally via SIMATIC I<strong>PC</strong> DiagMonitor)<br />

■ Integration<br />

Integrated interfaces:<br />

Ethernet<br />

The two integrated Gigabit Ethernet interfaces<br />

(10/100/1000 Mbit/s, teaming-capable) can be used for<br />

IT communication and for data exchange with programmable<br />

controllers such as SIMATIC S7 (with the "SOFTNET S7"<br />

software package).<br />

PROFINET<br />

The PROFINET interface can be used for connecting<br />

distributed field devices or for controlling drives<br />

(PROFINET RT via Standard Ethernet).<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/111<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>227D<br />

■ Technical specifications<br />

SIMATIC HMI I<strong>PC</strong>277D<br />

General features<br />

Processors Intel Atom E640 1.0 GHz, 1 GB RAM<br />

Intel Atom E660 1.3 GHz, 2 GB RAM<br />

available soon<br />

Chipset Intel Controller Hub EG20T<br />

Battery-backed MRAM 512 KB, of which 128 KB can be written<br />

within the buffer time<br />

Operating system without<br />

Windows XP Embedded Standard 2009<br />

preinstalled, in combination with CF card<br />

of 2 GB or more, or Solid-State Drive, or<br />

hard drive (optional)<br />

Windows XP Professional MUI (in combination<br />

with solid-state drive or hard drive;<br />

MUI: Multi Language User Interface)<br />

(optional)<br />

Windows 7 Ultimate and Windows<br />

Embedded Standard 7 available soon<br />

Linux1) (project-specific, on request)<br />

Others on request project-specifically<br />

Power supply 24 V DC (20.4 V ... 28.8 V)<br />

Isolated<br />

With buffering of temporary power failures:<br />

max. 10 ms<br />

Line side switch<br />

With power failure indication by means of<br />

Power Fail signal<br />

Drives<br />

FlashDrive Optional; replaceable, accessible,<br />

diagnosable<br />

2GB<br />

4 GB<br />

8GB<br />

Solid-State Drive (SSD) Optional<br />

50 GB SATA, 2.5" in single-level cell (SLC)<br />

technology, especially suitable for industrial<br />

applications<br />

CD/DVD/Floppy Via USB (not included in scope of delivery)<br />

Interfaces<br />

PROFINET PROFINET RT via Standard Ethernet<br />

controller<br />

Ethernet 2 x 10/100/1000 Mbit/s (RJ 45)<br />

Two independent Intel Controllers:<br />

Intel 82574L / Intel Controller Hub EG20T<br />

With teaming function<br />

USB V2.0/High Speed: 3 x<br />

Serial COM1 (V.24)<br />

Keyboard Via USB (not included in scope of delivery)<br />

Mouse Via USB (not included in scope of delivery)<br />

1) for specific LINUX versions in accordance with the specifications of<br />

the <strong>Siemens</strong> manufacturer's declaration "Suited for LINUX", see<br />

www.siemens.com/simatic-pc/suited-for-linux<br />

(LINUX is a trademark of Linus Torvald).<br />

5/112<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC HMI I<strong>PC</strong>277D<br />

Monitoring functions<br />

Temperature Processor temperature<br />

Motherboard<br />

Messages can be evaluated by the application<br />

program<br />

Watchdog Monitoring of program execution<br />

Monitoring time can be parameterized in<br />

software<br />

Can be parameterized for a fault or restart<br />

Messages can be evaluated by the application<br />

program.<br />

Monitoring functions via DiagBase<br />

the network<br />

SIMATIC I<strong>PC</strong> DiagMonitor<br />

Remote monitoring capability for:<br />

Watchdog<br />

Temperature<br />

Mass memory monitoring (SMART)<br />

System/Ethernet monitoring (Heart Beat)<br />

Runtime meter<br />

Communication:<br />

Ethernet interface (SNMP protocol)<br />

O<strong>PC</strong> for integration in SIMATIC software<br />

Configuration of client/server architectures<br />

Layout of log files<br />

Ambient conditions<br />

Degree of protection IP65/IP20<br />

according to EN 60529<br />

(front/rear)<br />

Ambient temperature 0 °C … 50 °C<br />

during operation<br />

Certifications<br />

Marine approval<br />

Available soon<br />

(available soon)<br />

Only for configurations<br />

with CompactFlash or<br />

SSD memory


■ Technical specifications (continued)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>227D<br />

Front panel<br />

Display<br />

SIMATIC HMI I<strong>PC</strong>277D<br />

7" TFT Touch, widescreen 9" TFT Touch, widescreen 12" TFT Touch, widescreen<br />

Resolution (W x H in pixels)<br />

Type of operation<br />

<strong>80</strong>0 x 4<strong>80</strong> <strong>80</strong>0 x 4<strong>80</strong> 12<strong>80</strong> x <strong>80</strong>0<br />

Function keys No No No<br />

Alphanumeric keyboard No No No<br />

Touch screen (analog/resistive) Yes Yes Yes<br />

Mouse on front<br />

Design<br />

No No No<br />

Centralized configuration Yes Yes Yes<br />

Distributed configuration<br />

Dimensions<br />

No No No<br />

Mounting dimensions in centralized<br />

configuration (W x H x D, without<br />

optical drive) in mm<br />

197 x 141 x 71 251 x 166 x 71 310 x 221 x 66<br />

Operator control unit (W x H) in mm 214 x 158 274 x 190 330 x 241<br />

Accessories Touch pen Touch pen Touch pen<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/113<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>227D<br />

■ Ordering data Order No. Order No.<br />

Configuration<br />

Accessories<br />

SIMATIC HMI I<strong>PC</strong>277D On request<br />

Touch pen<br />

Interfaces: 2 x Gbit LAN (RJ45),<br />

Undetachable pen for operation 6AV7 672-1JB00-0AA0<br />

1 x serial (COM1), 3 x USB<br />

of the touch devices, mounting of<br />

Operating unit<br />

Touch 7" TFT<br />

the support on the control cabinet<br />

or directly on the PRO unit<br />

Touch 9" TFT<br />

Note:<br />

Touch 12" TFT<br />

Software Packages with SIMATIC WinCC flexible,<br />

Touch 15" TFT, front USB<br />

interface<br />

SIMATIC WinCC and SIMATIC WinAC RTX (F) can be ordered<br />

together with the SIMATIC I<strong>PC</strong> with a price advantage.<br />

Touch 19" TFT, front USB<br />

More information under "Embedded Bundles / Packages for<br />

interface<br />

industrial <strong>PC</strong>s".<br />

Processors / memory expansion /<br />

retentivity<br />

Atom E660 (1.3 GHz), 2 GB RAM<br />

Please note:<br />

The HMI I<strong>PC</strong>277D with Bundle SW is always supplied with<br />

inserted CF card.<br />

Atom E660 (1.3 GHz),<br />

2 GB RAM, retentivity<br />

Atom E640 (1.0 GHz), 1 GB RAM<br />

Atom E640 (1.0 GHz),<br />

1 GB RAM, retentivity<br />

Drives<br />

Without drive, with CF slot<br />

2 GB SIMATIC I<strong>PC</strong><br />

CompactFlash<br />

4 GB SIMATIC I<strong>PC</strong><br />

CompactFlash<br />

8 GB SIMATIC I<strong>PC</strong><br />

CompactFlash<br />

50 GB Solid-State Drive SATA<br />

(SLC)<br />

Operating system<br />

Without operating system<br />

Windows Embedded Standard<br />

2009 preinstalled<br />

(CF from 2 GB/SSD)<br />

XP-Prof. MUI preinstalled on<br />

SSD<br />

Windows Embedded Standard 7<br />

preinstalled (CF from 4 GB/SSD)<br />

Windows 7 MUI preinstalled on<br />

SSD<br />

Software bundles<br />

Without RTX/HMI software<br />

RTX: WinAC RTX 2010<br />

RTX-F: WinAC RTX F 2010<br />

HMI: WinCC RT Advanced<br />

128 PT<br />

HMI: WinCC RT Advanced<br />

512 PT<br />

HMI: WinCC RT Advanced<br />

2048 PT<br />

HMI: WinCC RT Advanced<br />

4096 PT<br />

HMI/RTX: RT 128 PT<br />

HMI/RTX: RT 512 PT<br />

HMI/RTX: RT 2048 PT<br />

HMI/RTX: RT 4096 PT<br />

The licenses are on the supplied USB flash drive.<br />

5/114<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical specifications.<br />

158<br />

6.2<br />

71.1<br />

2.3<br />

HMI I<strong>PC</strong>277D 7"<br />

190<br />

6.2<br />

71.1<br />

2.3<br />

HMI I<strong>PC</strong>277D 9"<br />

214<br />

177.6<br />

196<br />

274<br />

35.7 177.6<br />

249<br />

140<br />

129.5<br />

■ More information<br />

Further information can be found on the Internet at:<br />

www.siemens.com/simatic-panel-pc<br />

36.5<br />

77.3<br />

36.5<br />

8.5<br />

4.8<br />

164<br />

129.5<br />

77.3<br />

32.5<br />

4.8<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00466<br />

G_<strong>ST</strong><strong>80</strong>_XX_00467<br />

241<br />

2.3 66.4 6.2<br />

HMI I<strong>PC</strong>277D 12"<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

330<br />

276<br />

308<br />

SIMATIC HMI I<strong>PC</strong>227D<br />

219<br />

38<br />

141.5<br />

75.5<br />

4.8<br />

72.6<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00468<br />

5/115<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>477C<br />

■ Overview<br />

Embedded <strong>PC</strong> platform with extremely high industrial compatibility<br />

for demanding tasks in the field of <strong>PC</strong>-based automation<br />

Maintenance-free (no rotating components such as fan and<br />

hard disk)<br />

Rugged construction: The <strong>PC</strong> is resistant to even the harshest<br />

mechanical stress and is extremely reliable in operation<br />

Compact design (only 61-69 mm installation depth for 12"-19")<br />

Battery-backed retentive memory onboard<br />

High investment protection<br />

Fast integration capability<br />

The following front versions are available:<br />

Built-in versions<br />

- 12" and 15" TFT Touch<br />

- 12" and 15" TFT Key<br />

- 19" Touch<br />

Support arm versions<br />

- PRO 15" and PRO 19" Touch<br />

- Fully enclosed device with degree of protection IP65 for<br />

mounting on a support arm/stand<br />

5/116<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Maximum industrial compatibility due to rugged construction,<br />

even when subjected to extreme vibration and shocks<br />

High degree of investment protection thanks to assured<br />

availability of spare parts (for a period of 5 years following the<br />

end of active marketing)<br />

High continuity of components for long-term machine<br />

concepts without renewed engineering outlay<br />

Savings in time and costs thanks to service-friendly device<br />

design:<br />

- USB 2.0 interfaces on the front and rear for quick and easy<br />

connection of additional hardware components<br />

High degree of industrial functionality thanks to integrated<br />

PROFIBUS DP/MPI and PROFINET interfaces<br />

Maintenance-free due to lack of rotating components (fan and<br />

hard disk)<br />

Minimized downtimes thanks to high system availability<br />

- Efficient self-diagnostics (DiagBase and SIMATIC I<strong>PC</strong><br />

DiagMonitor)<br />

- High reliability and security of an embedded platform<br />

Integrated component of Totally Integrated Automation (TIA):<br />

- Enhanced productivity, reduction of engineering overhead,<br />

reduction of lifecycle costs<br />

Complete turnkey solutions are supplied (the software is<br />

preinstalled and preconfigured) for visualization and<br />

automation, in combination with WinCC flexible and/or WinAC<br />

RTX as well as with WinCC.<br />

■ Application<br />

SIMATIC HMI I<strong>PC</strong>477C is designed for use directly at the<br />

machine, where the focus is on a combination of ruggedness<br />

and maximum reliability (the reliability of an embedded<br />

platform), and the openness of a <strong>PC</strong> is also required<br />

(e.g. module expansion and the connection of I/O devices such<br />

as printers, keyboards, etc.).<br />

Due to the minimal mounting depth, it can also be used in<br />

confined spaces.<br />

The <strong>PC</strong> can be used in production automation as well as in<br />

process automation and can be mounted in control cabinets,<br />

control desks, 19" cabinets/racks and as PRO version direct on<br />

swivel arms (booms).<br />

The SIMATIC HMI I<strong>PC</strong>477C is the ideal platform for <strong>PC</strong> based<br />

automation:<br />

<strong>PC</strong>-based visualization on-site at the machine with SIMATIC<br />

WinCC flexible, WinCC Advanced, or WinCC Professional<br />

<strong>PC</strong> based Control with SIMATIC WinAC RTX<br />

SIMATIC WinCC Client (standard or multi client) for distributed<br />

operation and monitoring<br />

SIMATIC WinCC as single-user station solution for centralized<br />

operation and monitoring (also in combination with<br />

WinCC WebNavigator server)<br />

<strong>Siemens</strong> offers a complete modular system of automation<br />

components that complement one another perfectly.


■ Design<br />

The HMI I<strong>PC</strong>477C is a compact device comprising an operator<br />

control unit with integrated computer unit.<br />

Standard components of the computer unit:<br />

Rugged metal enclosure, resistant to vibration and shock, with<br />

high electromagnetic compatibility<br />

Processors:<br />

- Intel Celeron M 1.2 GHz, Intel Core2 Solo 1.2 GHz or Intel<br />

Core2 Duo 1.2 GHz<br />

Main memory basic configuration:<br />

- 1, 2 or 4 GB (DDR3)<br />

- Battery-backed retentive memory 2 MB<br />

CompactFlash Drive (internal) with pre-installed Windows XP<br />

embedded operating system (Image) and optional software or<br />

Solid State Drive (SSD) with Windows XP Embedded or<br />

Windows XP Professional (MUI)<br />

Graphics onboard (12<strong>80</strong> x 1024)<br />

Interfaces:<br />

- 2 x PROFINET (IE) onboard (10/100/1000 Mbit/s)<br />

- Optional 2 x PROFINET (IE) onboard (10/100/1000 Mbit/s)<br />

and 1 x PROFIBUS DP/MPI onboard, CP 5611-compatible<br />

- Optional 1 x PROFINET (IE) onboard (10/100/1000 Mbit/s)<br />

and 1 x PROFINET (RT/IRT) with 3 ports,<br />

CP 1616-compatible<br />

- 5 x USB 2.0 port, 500 mA (1 x on front)<br />

- 1 x COM1 (RS232)<br />

- 1 x DVI-I (for connecting a second display unit)<br />

Battery-backed retentive memory onboard<br />

Free slots for expansions:<br />

- 1 x CompactFlash slot (externally accessible)<br />

Power supply: 24 V DC<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>477C<br />

Components of the operator control unit:<br />

The operator control units are available in the following versions:<br />

12" Key<br />

12" TFT color display, <strong>80</strong>0 x 600 pixels (SVGA)<br />

Membrane keyboard with international <strong>PC</strong> character set and<br />

36 additional function keys as well as integrated mouse<br />

USB port (on the front)<br />

12" Touch<br />

12" TFT color display, <strong>80</strong>0 x 600 pixels (SVGA)<br />

Resistive analog touch screen<br />

USB port (on the front)<br />

15" Key<br />

15" TFT color display, 1024 x 768 pixels (XGA)<br />

Membrane keyboard with international <strong>PC</strong> character set and<br />

36 additional function keys as well as integrated mouse<br />

USB port (on the front)<br />

15" Touch<br />

15" TFT color display, 1024 x 768 pixels (XGA)<br />

Resistive analog touch screen<br />

USB port (on the front)<br />

19" Touch<br />

19" TFT color display, 12<strong>80</strong> x 1024 (SXGA)<br />

Resistive analog touch screen<br />

USB port (on the front)<br />

PRO 15" Touch<br />

Fully enclosed device with degree of protection IP65 for<br />

mounting on a support arm/stand<br />

15" TFT color display, 1024 x 768 pixels (XGA)<br />

Resistive analog touch screen<br />

PRO 19" Touch<br />

Fully enclosed device with degree of protection IP65 for<br />

mounting on a support arm/stand<br />

19" TFT color display, 12<strong>80</strong> x 1024 (SXGA)<br />

Resistive analog touch screen<br />

The built-in devices are equipped with an USB 2.0 interface at<br />

the front for connecting external I/O devices such as a mouse or<br />

keyboard and at the front fulfill the requirements of degree of<br />

protection IP65 and NEMA 4.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/117<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>477C<br />

■ Design (continued)<br />

HMI I<strong>PC</strong>477C PRO 15"/19" Touch devices<br />

For mounting on a support arm/stand<br />

All-round IP65, enclosure type 4x<br />

15"/19" Touch Display<br />

Rugged aluminum enclosure<br />

Two internal USB interfaces, one of which can be<br />

implemented as "USB service interface" using accessories<br />

Adaptation of the device optionally from above or below<br />

Direct connection on support arm systems from renowned<br />

manufacturers (e.g. Rittal, Bernstein, Rose, Rolec)<br />

Supports the globally established VESA 75 / VESA 100<br />

standard for flexible mounting<br />

Customer-side expansion possible using extension units<br />

SIMATIC HMI I<strong>PC</strong>477C bundles:<br />

HMI, RTX, RTX F and HMI/RTX<br />

(Bundles with WinCC RT Advanced and WinCC RT Professional<br />

available soon)<br />

HMI, RTX, RTX F and HMI/RTX complete turnkey solutions (the<br />

software is already preinstalled and configured) for visualization<br />

and automation in combination with WinCC flexible and<br />

WinAC RTX<br />

Quick start in automation solutions with Embedded<br />

Automation<br />

HMI: SIMATIC WinCC flexible RT preinstalled and ready to use<br />

RTX: SIMATIC WinAC RTX preinstalled and ready to use<br />

RTX F: SIMATIC WinAC RTX F preinstalled and ready to use<br />

HMI/RTX (F): SIMATIC WinCC flexible and SIMATIC<br />

WinAC RTX (F) preinstalled and ready to use<br />

PROFIBUS and PROFINET (RT/IRT) preconfigured for use in a<br />

SIMATIC environment<br />

Configuration and programming with SIMATIC<br />

WinCC flexible ES and SIMATIC <strong>ST</strong>EP 7 via Industrial Ethernet<br />

or PROFIBUS<br />

Flexibility of a <strong>PC</strong>-based automation environment<br />

Open for additional <strong>PC</strong> applications<br />

Connection option for USB devices, flat panel monitor or<br />

screen<br />

Use of WinAC ODK with SIMATIC WinAC RTX<br />

Data retentivity for WinAC RTX without uninterruptible power<br />

supply (UPS)<br />

5/118<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC HMI I<strong>PC</strong>477C as WinCC client or single-user station<br />

Selected hardware configuration with preinstalled software<br />

WinCC V7.0 RT as<br />

ready-to-run client (standard and multi-client) in a WinCC<br />

multi-user station, or<br />

ready-to-run single-user station with process connection<br />

Expansion components<br />

SIMATIC I<strong>PC</strong> DiagMonitor<br />

<strong>PC</strong> diagnostics/alarm software for early detection and<br />

diagnosis of <strong>PC</strong> problems<br />

Comprehensive monitoring of temperature, watchdog<br />

Operating hours counter for preventive maintenance<br />

Integrated log functions, comprehensive text messages,<br />

online help (English/German)<br />

Network-wide monitoring via SNMP and O<strong>PC</strong> interface<br />

possible<br />

SIMATIC I<strong>PC</strong> Image & Partition Creator<br />

Software tool for preventive data back-up of the contents of<br />

bulk storage (CF cards, hard disks)<br />

High-speed restoring of system and data partitions with bit<br />

accuracy; user software and special installations are also<br />

backed up<br />

Software tool for adaptation of mass storage partitioning<br />

3.5" USB disk drive<br />

The USB disk drive is provided for fast exchange of user data,<br />

e.g. recipes or files. The drive must not be used as a cyclic<br />

archiving drive. The front-panel installation and degree of<br />

protection IP54 permit data exchange from the front without<br />

opening the control cabinet door.<br />

The device is connected via the USB interface of the Panel <strong>PC</strong>.<br />

The power is also supplied over the USB interface. A USB cable<br />

of 1 m length is included in the scope of supply. The disk drive<br />

corresponds to the USB 1.1 standard. 3.5" high density disks<br />

can be used (1.44 MB).


■ Design (continued)<br />

Operation of the USB disk drive on SIMATIC Panel <strong>PC</strong>s:<br />

Windows XP: possible without separate driver<br />

The driver is included in the scope of supply of the operating<br />

system<br />

SIMATIC I<strong>PC</strong> USB FlashDrive<br />

Mobile memory medium for SIMATIC <strong>PC</strong>/PG<br />

Fast data transfer (USB 2.0) and high memory capacity<br />

Ultra-compact and rugged<br />

SIMATIC I<strong>PC</strong> Service USB FlashDrive<br />

Mobile memory medium for backing up/restoring mass<br />

memories<br />

Pre-installed Image & Partition Creator V3.0<br />

Ultra-compact and rugged<br />

Industrial USB Hub 4<br />

Industry-standard USB 2.0 hub, front IP65<br />

Installation in control cabinet door or on DIN rail<br />

Inspection window and LEDs for each of the four interfaces<br />

Note:<br />

For further information, see "Expansion components".<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Function<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>477C<br />

Diagnosis<br />

DiagBase: Integrated, parameterizable monitoring functions<br />

(program execution/watchdog, internal enclosure<br />

temperature, DIAG bit for CF cards similar to S.M.A.R.T for<br />

hard disks)<br />

Expanded diagnostics/messages via Ethernet, e-mail, text<br />

message and for direct transfer to SIMATIC software via O<strong>PC</strong><br />

(optionally via SIMATIC I<strong>PC</strong> DiagMonitor)<br />

■ Integration<br />

Integrated interfaces:<br />

Ethernet<br />

The integrated PROFINET interfaces (10/100/1000 Mbit/s) can<br />

be used for IT communication and for data exchange with<br />

PLCs such as SIMATIC S7 (with "SOFTNET S7" software<br />

packages). Selectable option: PROFINET (RT/IRT) with 3 ports<br />

instead of one PROFINET (IE).<br />

PROFIBUS onboard (option)<br />

The isolated PROFIBUS interface (12 Mbit/s) can be used for<br />

connecting distributed field devices or for coupling to<br />

SIMATIC S7 (with software packages "SOFTNET for<br />

PROFIBUS").<br />

Other interfaces<br />

5 USB (Universal Serial Bus) interfaces and one serial<br />

interface are available for connecting additional I/O devices.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/119<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>477C<br />

■ Technical specifications<br />

6AV7 884..<br />

General features<br />

Processors Intel Celeron M 1.2 GHz, Intel Core2 Solo<br />

1.2 GHz or Core2 Duo 1.2 GHz<br />

Memory type DDR3-RAM<br />

Main memory 1 GB, 2 GB or 4 GB<br />

Free slots 1 x CF card slot (externally accessible)<br />

Operating system Windows Embedded Standard 2009,<br />

Windows XP Professional MUI 1) , Windows 7<br />

Ultimate MUI 1) or Windows Embedded<br />

Standard 7<br />

Additional OS information Language: ENG/GER<br />

SIMATIC Software Optionally with pre-installed bundle<br />

software SIMATIC WinCC flexible 2008 SP2<br />

and/or WinAC RTX 2010 SIMATIC WinAC<br />

RTX F 2010; SIMATIC WinCC V7.0 as Web<br />

Client or Standard Client<br />

Drives<br />

Floppy disk drive Optionally via external USB floppy disk<br />

drive<br />

Optical drives Possible as external drive via USB<br />

Hard drive/mass storage CompactFlash drive with 2, 4 or 8 GB<br />

and/or SSD (Solid State Drive) with 32 GB<br />

Interfaces<br />

Graphic interface DVI-I can be used for additional display unit<br />

(only VGA via adapter); color depth 32 bits,<br />

graphics memory up to 128 MB; resolution<br />

as on relevant integrated display<br />

Connection for keyboard/ USB / USB<br />

mouse<br />

Serial interface COM1: 1 x V.24 (RS232)<br />

PROFIBUS/MPI Optionally onboard, isolated, max.<br />

12 Mbit/s, no plug-in card required,<br />

CP 5611-compatible, not upgradeable<br />

PROFINET (RT/IRT) Optional: 3 x RJ45, CP 1616-compatible;<br />

not upgradeable<br />

USB 1 x on front, 4 x on rear, USB 2.0 (500 mA)<br />

PROFINET (IE), Ethernet onboard, 2 x 10/100/1000 Mbit (RJ45 with/<br />

without PROFIBUS), 1 x 10/100/1000 Mbit<br />

(RJ45 with PROFINET (RT/IRT)), no plug-in<br />

card required<br />

5/120<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV7 884..<br />

Supply voltage<br />

Supply voltage 24 V DC<br />

Monitoring functions<br />

Temperature Yes<br />

Watchdog Yes<br />

Diagbit (similar to Yes (for CF cards and SSD)<br />

S.M.A.R.T.)<br />

Status LEDs Yes (on rear)<br />

Front side according to IP65 (on the front) according to EN 60529<br />

EN 60529<br />

and NEMA4<br />

Ambient conditions<br />

Vibration load during Tested in accordance with IEC 60068-2-6:<br />

operation<br />

10 - 58 Hz: 0.075 mm, 58 to 200 Hz:<br />

9.8 m/s² (1 g)<br />

Shock load during Tested in accordance with<br />

operation<br />

IEC 60068-2-7: 50 m/s² (5 g), 30 ms,<br />

100 shocks<br />

Relative humidity Tested in accordance with DIN IEC 68-78,<br />

DIN IEC 60068-2-30: 5% to <strong>80</strong>% at 25 °C<br />

(no condensation)<br />

Maximum permissible 45° over vertical<br />

installation angle +/-<br />

Ambient temperature 0 °C … +50 °C in maximum configuration;<br />

during operation<br />

no fan<br />

Certifications &<br />

standards<br />

Approvals CE, cULus(508), Marine<br />

EMC CE, FFC A, 55022A, EN 61000-6-4,<br />

EN 61000-6-2<br />

1) Multi language means: GER/ENG/FR/IT/SP/CHIN traditional/CHIN<br />

simplified/Korean/Japanesee


■ Technical specifications (continued)<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>477C<br />

6AV7 884-0 6AV7 884-1 6AV7 884-2 6AV7 884-3 6AV7 884-5<br />

Front panel 12" TFT Touch 12" TFT Key 15" TFT Touch 15" TFT Key 19" TFT Touch<br />

Display<br />

Resolution<br />

(W x H in pixels)<br />

MTBF of backlighting<br />

(at 25 °C)<br />

<strong>80</strong>0 x 600 <strong>80</strong>0 x 600 1024 x 768 1024 x 768 12<strong>80</strong> x 1024<br />

50000 h at 24 h<br />

continuous operation,<br />

temperaturedependent<br />

50000 h at 24 h<br />

continuous operation,<br />

temperaturedependent<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

50000 h at 24 h<br />

continuous operation,<br />

temperaturedependent<br />

50000 h at 24 h<br />

continuous operation,<br />

temperaturedependent<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

50000 h at 24 h<br />

continuous operation,<br />

temperaturedependent<br />

Type of operation<br />

Function keys No 36 No 36 No<br />

Alphanumeric keyboard No Yes No Yes No<br />

Touch screen<br />

(analog/resistive)<br />

Yes No Yes No Yes<br />

Mouse on front<br />

Design<br />

No Yes No Yes No<br />

Centralized<br />

configuration<br />

Yes Yes Yes Yes Yes<br />

Distributed configuration<br />

Dimensions<br />

No No No No No<br />

Mounting dimensions in<br />

centralized configuration<br />

(W x H x D, without<br />

optical drive) in mm<br />

368 x 290 x 61 450 x 290 x 61 450 x 290 x 65 450 x 321 x 60 450 x 3<strong>80</strong> x 71<br />

Operator control unit<br />

(W x H) in mm<br />

400 x 310 (7 HU) 483 x 310 (19", 7 HU) 483 x 310 (19", 7 HU) 483 x 355 (19", 8 HU) 483 x 400 (19", 9 HU)<br />

Weight<br />

General features<br />

6.1 kg 6.6 kg 7.0 kg 7.2 kg 9.5 kg<br />

Accessories Touch protective Insertable strips for Touch protective Insertable strips for Touch protective<br />

membranes, touch keyboard<br />

membranes, touch keyboard<br />

membranes, touch<br />

pen<br />

pen<br />

pen<br />

Max. power loss in<br />

maximum configuration<br />

40 W 40 W 45 W 45 W 60 W<br />

5/121<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>477C<br />

("built to order" versions with a<br />

delivery time of max. 15 working<br />

days and with original part repair,<br />

if not preferred type)<br />

SIMATIC HMI I<strong>PC</strong>477C<br />

Embedded and fan-free 5 x USB<br />

(500 mA), of which 1 x on the<br />

front, battery-backed retentive<br />

E 4<br />

memory onboard, 24 V DC power<br />

supply with On/Off switch<br />

SIMATIC HMI I<strong>PC</strong>477C PRO<br />

Embedded and fan-free with fully<br />

E 3<br />

enclosed IP65 enclosure; 5 x USB<br />

(500 mA), of which 1 x on the<br />

front, battery-backed retentive<br />

memory onboard, 24 V DC power<br />

supply with On/Off switch<br />

Front Panels<br />

12" TFT Touch<br />

(not for PRO versions) 1) 4 0<br />

12" TFT Key<br />

(not for PRO versions)<br />

4 1<br />

15" TFT Touch<br />

(not for PRO versions) 1) 4 2<br />

15" TFT Key<br />

(not for PRO versions)<br />

4 3<br />

19" TFT Touch<br />

(not for PRO versions) 1)<br />

4 5<br />

15" TFT Touch<br />

(IP65 enclosure; PRO)<br />

3 6<br />

15" TFT Key<br />

(IP65 enclosure; PRO)<br />

Processors and fieldbus<br />

Celeron M 1.2 GHz,<br />

2 x PROFINET (IE)<br />

3 7<br />

1)<br />

Celeron M 1.2 GHz,<br />

2 x PROFINET (IE),<br />

1 x PROFIBUS DP 12 1)<br />

Core2 Solo 1.2 GHz,<br />

2 x PROFINET (IE) 1)<br />

Core2 Solo 1.2 GHz,<br />

2 x PROFINET (IE),<br />

1 x PROFIBUS 1)<br />

Core2 Solo 1.2 GHz,<br />

1 x PROFINET (IE),<br />

1 x PROFINET (RT/IRT) (3 ports)<br />

Core2 Duo 1.2 GHz,<br />

2 x PROFINET (IE) 1)<br />

Core2 Duo 1.2 GHz,<br />

2 x PROFINET (IE),<br />

1 x PROFIBUS 1)<br />

Core2 Duo 1.2 GHz,<br />

1 x PROFINET (IE),<br />

1 x PROFINET (RT/IRT) (3 ports)<br />

5/122<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

E<br />

F<br />

G<br />

H<br />

J<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

1 1<br />

1<br />

■ Ordering data Order No. Order No.<br />

Configuration<br />

Configuration<br />

SIMATIC HMI I<strong>PC</strong>477C and E 6AV7 88 17 - 17 A 7 7 7 - 7 7 7 0 SIMATIC HMI I<strong>PC</strong>477C and E 6AV7 88 7 - 17 A 7 77- 777 0<br />

I<strong>PC</strong>477C PRO<br />

I<strong>PC</strong>477C PRO<br />

Main memory (DDR3 RAM),<br />

1 bank<br />

1 GB 1<br />

2 GB<br />

A<br />

B<br />

D<br />

1) 2<br />

4GB<br />

Second mass storage<br />

(installed and formatted)<br />

3<br />

Without1) 0<br />

CompactFlash 2 GB 1) 2<br />

CompactFlash 4 GB 1) 3<br />

CompactFlash 8 GB 1) 4<br />

SSD (Solid State Drive),<br />

min. 32 GB<br />

Mass storage (built-in, operating<br />

system pre-installed)<br />

6<br />

CompactFlash 2 GB<br />

(only with Windows Embedded<br />

Standard 2009) 1)<br />

2<br />

CompactFlash 4 GB 1) 3<br />

CompactFlash 8 GB 1) 4<br />

SSD (Solid State Disk),<br />

min. 32 GB<br />

Operating system<br />

(preinstalled and activated)<br />

6<br />

Windows Embedded Standard<br />

2009 1)<br />

B A<br />

Windows XP Professional<br />

multi language, only with SSD;<br />

without SIMATIC software<br />

D A<br />

Windows Embedded<br />

Standard 7 2)<br />

4 E A<br />

Windows 7 Ultimate, MUI<br />

(Eng, Ger, Fr, It, Sp) only with<br />

SSD; without SIMATIC software<br />

4 G A<br />

SIMATIC HMI I<strong>PC</strong>477C (PRO)<br />

with SIMATIC software<br />

See Embedded bundles/<br />

packages for industrial <strong>PC</strong>s<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

1) Preferred types with replacement devices in exchange<br />

2) Only with CF > 4 GB or SSD and from 2 GB main memory)<br />

Note:<br />

Software Packages with SIMATIC WinCC flexible,<br />

SIMATIC WinCC and SIMATIC WinAC RTX (F) can be ordered<br />

together with the SIMATIC I<strong>PC</strong> with a price advantage.<br />

More information under "Embedded Bundles / Packages for<br />

industrial <strong>PC</strong>s".


<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

■ Ordering data Order No. Order No.<br />

Accessories<br />

Protective film for Panel <strong>PC</strong>s<br />

477/577/677<br />

For protecting the touch screen<br />

against dirt/scratches<br />

for 12" Touch 6AV7 671-2BA00-0AA0<br />

for 15" Touch (not for PRO) 6AV7 671-4BA00-0AA0<br />

for 19" Touch 6AV7 672-1CE00-0AA0<br />

Labeling membranes for Panel 6AV7 672-0DA00-0AA0<br />

<strong>PC</strong>s 477/577/677<br />

For labeling soft keys and<br />

function keys, blank, supplied in<br />

sets of 10<br />

Touch pen 6AV7 672-1JB00-0AA0<br />

Captive pen for operation of the<br />

touch devices, mounting of the<br />

support on the control cabinet or<br />

directly on the PRO unit<br />

Please be sure to note:<br />

The HMI I<strong>PC</strong>477C is delivered as standard with an inserted CF card.<br />

The licenses are located on the supplied USB flash drive.<br />

Note:<br />

Further embedded versions based on I<strong>PC</strong>427C and Embedded<br />

Controller (mEC) are listed under SIMATIC <strong>PC</strong>-based Control.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Expansion components<br />

SIMATIC HMI I<strong>PC</strong>477C<br />

SIMATIC I<strong>PC</strong> DiagMonitor V4.2 B 6ES7 648-6CA04-2YX0<br />

Software tool for monitoring<br />

SIMATIC I<strong>PC</strong>s,<br />

incl. manual, on CD-ROM<br />

(German/English)<br />

SIMATIC I<strong>PC</strong> Image & Partition D<br />

Creator V3.1<br />

Software tool for preventive data<br />

backup and hard disk partitioning<br />

for SIMATIC I<strong>PC</strong>s, incl. manual on<br />

CD-ROM (German, English)<br />

6ES7 648-6AA03-1YA0<br />

SIMATIC I<strong>PC</strong> USB FlashDrive<br />

8 GB, USB 2.0, metal enclosure,<br />

bootable<br />

A 6ES7 648-0DC50-0AA0<br />

SIMATIC I<strong>PC</strong> Service USB<br />

FlashDrive<br />

8 GB, USB 2.0; metal enclosure,<br />

bootable, Image & Partition<br />

Creator pre-installed, incl. CD<br />

B 6AV7 672-8JD01-0AA0<br />

SINUMERIK disk drive 3.5",<br />

USB 1.1<br />

with 1 m connecting cable<br />

6FC5 235-0AA05-1AA2<br />

Industrial USB Hub 4<br />

4 x USB 2.0, IP65 for control<br />

cabinet door or DIN rail<br />

CompactFlash Card<br />

A 6AV6 671-3AH00-0AX0<br />

2 GB A 6ES7 648-2BF02-0XF0<br />

4GB A 6ES7 648-2BF02-0XG0<br />

8 GB A 6ES7 648-2BF02-0XH0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/123<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>477C<br />

■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical specifications.<br />

10.5<br />

60.3<br />

310.3<br />

235<br />

SIMATIC HMI I<strong>PC</strong>477C 12" Key version<br />

10.5<br />

60.3<br />

310.3<br />

19.5<br />

SIMATIC HMI I<strong>PC</strong>477C 12" Touch version<br />

5/124<br />

65.1<br />

328<br />

447.2<br />

328<br />

366<br />

400<br />

482.6<br />

465<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

37.3<br />

44<br />

288.3<br />

288.3<br />

70.8<br />

70.8<br />

59.15 207.5<br />

59.15 207.5<br />

4.8<br />

4.8<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00395<br />

G_<strong>ST</strong><strong>80</strong>_XX_00396<br />

10.5<br />

59.3<br />

354.8<br />

235<br />

65.1<br />

328<br />

447.2<br />

482.6<br />

SIMATIC HMI I<strong>PC</strong>477C 15" Key version<br />

310.3<br />

10.5<br />

64.1<br />

235<br />

88.1<br />

465<br />

447.2<br />

482.6<br />

465<br />

328<br />

SIMATIC HMI I<strong>PC</strong>477C 15" Touch version<br />

40.1<br />

43.5<br />

319.4<br />

74.6<br />

288.3<br />

69.8<br />

74.7 207.5<br />

4.8<br />

59.1 207.5<br />

4.8<br />

G_<strong>ST</strong><strong>80</strong>_XX_00397<br />

G_<strong>ST</strong><strong>80</strong>_XX_00398


■ Dimensional drawings (continued)<br />

10.5<br />

70.5<br />

400<br />

235<br />

88.1<br />

328<br />

447.2<br />

482.6<br />

465<br />

SIMATIC HMI I<strong>PC</strong>477C 19" Touch version<br />

40.9<br />

81<br />

378<br />

207.5<br />

104<br />

4.8<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00399<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>477C<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-panel-pc<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/125<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>577C<br />

■ Overview<br />

Rugged, expandable industry <strong>PC</strong> for demanding tasks in the<br />

area of <strong>PC</strong>-based automation with various control units<br />

(front panels):<br />

Rugged and compact design for industrial use<br />

Full <strong>PC</strong> openness<br />

- Windows Embedded Standard or Windows XP Professional,<br />

or without operating system<br />

- CF card, HDD, SSD<br />

- DVD drive<br />

Expandable using a <strong>PC</strong>I slot<br />

Optionally with PROFIBUS or PROFINET (RT/IRT) onboard<br />

Installation-compatible with Panel <strong>PC</strong> 577B<br />

- Touch screen control units with 12", 15" and 19" TFT display<br />

- 12" and 15" TFT Key<br />

High degree of investment protection<br />

5/126<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

High performance due to powerful processor<br />

Low-cost entry-level industry <strong>PC</strong> with full <strong>PC</strong> openness.<br />

Ideal for applications in industrial environments due to<br />

- excellent operational reliability – even when subjected to<br />

extreme vibration and shock<br />

- high degree of chemical resistance to oils and grease<br />

- smooth front, therefore no dirt can accumulate<br />

- brilliant displays for good clearness of display, even when<br />

lighting conditions and viewing angles change.<br />

High degree of investment protection due to<br />

- a long marketing period (4 - 5 years) and high continuity of<br />

components for long-term machine concepts<br />

- assured availability of spare parts (for a period of 5 years<br />

following the end of active marketing)<br />

- simple migration from the predecessor product with<br />

minimum engineering overhead<br />

- same installation dimensions as predecessor<br />

- early detection of faults and minimized downtimes due to<br />

self-diagnostics (DiagBase)<br />

High level of flexibility due to<br />

- expandable by the customer thanks to diverse interfaces<br />

(<strong>PC</strong>I, CompactFlash, Gbit Ethernet, and others)<br />

- USB interfaces on the front and rear for quick and easy<br />

connection of additional hardware components<br />

- User-friendly and easy integration in the fieldbus level,<br />

thanks to integrated PROFIBUS DP/MPI and 2 Gigabit<br />

Ethernet interfaces (onboard)<br />

■ Application<br />

The SIMATIC HMI I<strong>PC</strong>577C is used in manufacturing automation<br />

and process automation. The device is designed for installation<br />

in control cabinets and consoles, 19" cabinets/racks, and swivel<br />

arms (booms). Due to the minimal mounting depth, it can also be<br />

used in confined spaces, e. g. 83 mm for 15" Touch.<br />

Thanks to its full <strong>PC</strong> openness and the powerful Core2 Duo<br />

processor, it can be used for a host of different applications.<br />

A SIMATIC HMI I<strong>PC</strong>577C is the ideal platform for <strong>PC</strong>-based<br />

automation:<br />

<strong>PC</strong>-based visualization on site at the machine with<br />

SIMATIC WinCC flexible<br />

Complex solutions with SIMATIC WinCC process visualization<br />

<strong>PC</strong>-based control with SIMATIC WinAC software PLC<br />

SIMATIC HMI I<strong>PC</strong>s can be ordered in combination with<br />

WinCC flexible or WinCC as SIMATIC HMI packages at a lower<br />

price.


■ Design<br />

The SIMATIC HMI I<strong>PC</strong> is equipped as follows:<br />

Computing unit<br />

Processor:<br />

- Intel Core2 Duo processor 1.86 GHz or<br />

- Intel Core2 Solo 1.2 GHz or<br />

- Intel Celeron M 1.2 GHz<br />

Main memory expansion:<br />

- 1 GB, 2 GB or 4 GB (SO-DIMM DDR3)<br />

Retentive memory<br />

Mass storage<br />

- Solid-State Drive (SSD) ≥ 32 GB for maximum shock<br />

tolerance since there are no rotating parts, or<br />

- Hard disk HDD ≥ 250 GB (2.5" SATA) with vibrationabsorbent<br />

hard disk holder, which ensures reliable operation<br />

even under conditions of high mechanical stress, and/or<br />

- CF card (2 GB, 4 GB, or 8 GB)<br />

Onboard graphics<br />

Interfaces:<br />

- 2 x 10/100/1000 PROFINET (IE)<br />

- 4 x USB 2.0 interfaces on rear + 1 x USB 2.0 interface on<br />

front; all high current (500 mA)<br />

- 1 x serial V.24 (9-pin)<br />

Free slots for expansions:<br />

- 1 x <strong>PC</strong>I (slots with card retainer)<br />

- 1 x slot for CompactFlash Card (accessible from outside)<br />

Power supply:<br />

- 24 V DC or 100/240 V AC (autorange), 50/60 Hz<br />

Drive (optional)<br />

- DVD±RW±R combo drive<br />

Fieldbus onboard (optional)<br />

- 1 x PROFIBUS DP12/MPI interface (CP 5611-compatible)<br />

and 2 x LAN 1 Gbit/s<br />

- 1 x PROFINET RT/IRT (3 Port), CP 1616-compatible<br />

Operating unit<br />

Operating units are available in the following sizes/resolutions:<br />

12" Key: 12.1" TFT color display, <strong>80</strong>0 x 600 pixels<br />

Membrane keyboard with tactile feedback and integrated<br />

mouse<br />

12" Touch: 12.1" TFT color display, <strong>80</strong>0 x 600 pixels (SVGA)<br />

15" Key: 15.1" TFT color display, 1024 x 768 pixels<br />

Membrane keyboard with tactile feedback and integrated<br />

mouse<br />

15" Touch: 15.1" TFT color display, 1024 x 768 pixels (XGA)<br />

19" Touch: 19.1" TFT color display, 12<strong>80</strong> x 1024 pixels (SXGA)<br />

The operating units have the following functionality:<br />

Analog resistive touch screen or tactile membrane keyboard<br />

with system keys and 36 user-configurable function keys<br />

Degree of protection IP65 and NEMA 4<br />

USB 2.0 interface on the front for connecting external<br />

I/O devices such as mouse or keyboard<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>577C<br />

Expansion components<br />

SIMATIC I<strong>PC</strong> DiagMonitor<br />

<strong>PC</strong> diagnostics/alarm software for the early detection and<br />

diagnosis of <strong>PC</strong> problems<br />

SIMATIC I<strong>PC</strong> Image & Partition Creator<br />

Software tool for preventive data back-up of the contents of<br />

bulk storage (CF cards, hard disks)<br />

High-speed restoring of system and data partitions with bit<br />

accuracy; user software and special installations are also<br />

backed up<br />

Software tool for adaptation of mass storage partitioning.<br />

SIMATIC <strong>PC</strong> USB FlashDrive<br />

Mobile memory medium for SIMATIC <strong>PC</strong>/PG<br />

SIMATIC I<strong>PC</strong> Service USB FlashDrive<br />

Mobile memory medium for backing up/restoring mass<br />

memories<br />

Pre-installed Image & Partition Creator V3.0<br />

Ultra-compact and rugged<br />

Industrial USB Hub 4<br />

Industry-standard USB 2.0 hub, front IP65<br />

Additional accessories<br />

Touch pen (cannot be lost) for operating the touch devices<br />

Protective membranes to protect the touch screen against<br />

dirt/scratches<br />

Labeling membranes for labeling user-configurable function<br />

keys of key devices<br />

■ Function<br />

Diagnosis<br />

Integrated, parameterizable monitoring functions: Program<br />

execution (watchdog), internal temperature of enclosure, fan<br />

speed<br />

Expanded diagnostics/messages via Ethernet, e-mail, text<br />

message and for direct transfer to SIMATIC software via O<strong>PC</strong><br />

(optionally via SIMATIC <strong>PC</strong> DiagMonitor)<br />

■ Integration<br />

Integrated interfaces:<br />

<strong>PC</strong>I<br />

One free <strong>PC</strong>I slot is available for expansion with plug-in cards.<br />

Ethernet<br />

The integrated PROFINET (IE) interfaces (10/100/1000 Mbit/s)<br />

can be used for IT communication and for exchanging data<br />

with programmable controllers such as SIMATIC S7<br />

(with the "SOFTNET S7" software packages).<br />

Further interfaces<br />

One CompactFlash Card slot, 5 x USB 2.0 interfaces<br />

(Universal Serial Bus), as well as one serial interface are<br />

available for further I/O devices.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/127<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>577C<br />

■ Technical specifications<br />

6AV7 885..<br />

General features<br />

Processors Intel Celeron M 1.2 GHz or Intel<br />

Core2 Solo 1.2 GHz or Intel<br />

Core2 Duo 1.86 GHz<br />

Memory type DDR3-RAM<br />

Main memory 1 GB, 2 GB or 4 GB<br />

Free slots for expansions 1x CF card slot<br />

(externally accessible)<br />

1 x <strong>PC</strong>I slot<br />

Operating system Windows Embedded Standard<br />

2009, Windows XP Professional<br />

MUI, Windows 7 Ultimate MUI or<br />

Windows Embedded<br />

Standard 7 1)<br />

Additional OS information Language: ENG/GER<br />

MTBF backlighting Typ. 50 000 h at 24 h continuous<br />

operation, temperaturedependent<br />

Drives<br />

Floppy drive Optional via external USB floppy<br />

drive<br />

Optical drives Optional DVD±RW±R combo<br />

drive<br />

Hard disk/mass storage SSD (Solid State Drive) with<br />

32 GB and/or HDD with 250 GB<br />

and/or CompactFlash with 2,<br />

4 or 8 GB<br />

Interfaces<br />

External graphic interface DVI-I for additional display unit:<br />

Color depth 32 bits<br />

Connection for keyboard/mouse USB / USB<br />

Serial interface COM1: 1 x V.24 (RS232)<br />

PROFIBUS DP/MPI Optionally onboard, isolated,<br />

max. 12 Mbit/s, no plug-in card<br />

required, CP 5611-compatible,<br />

not upgradable<br />

PROFINET (RT/IRT) Optional onboard, 3 x RJ 45,<br />

CP 1616-compatible, not<br />

upgradeable<br />

PROFINET (IE), Ethernet Onboard, 2 x 10/100/1000 Mbit<br />

(RJ45 without/with PROFIBUS),<br />

1 x 10/100/1000 Mbit (RJ45 with<br />

PROFINET), no plug-in card<br />

necessary<br />

USB 1 x on front, 4 x on rear, USB 2.0<br />

(500 mA)<br />

1) Multi language means: Ger/Eng/Fr/It/Sp/CHIN traditional/CHIN<br />

simplified/Korean/Japanese<br />

2) 61000-6-2 replaces 50082-2; 61000-6-4 replaces 50081-2<br />

3) Valid with CF or SSD; with HDD: 5 g/0.5 g<br />

4) Valid with CF or SSD; with HDD: +5 °C to 45 °C<br />

5/128<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Supply voltage<br />

Supply voltage 24 V DC or 100/240 V AC<br />

Monitoring functions<br />

Temperature Yes<br />

Watchdog Yes<br />

Diagbit (similar to S.M.A.R.T.) Yes (for CF cards, HDD and SSD)<br />

Front side according to EN 60529 IP65 (on the front), tested<br />

according to EN 60529 and<br />

NEMA4<br />

Ambient conditions<br />

Vibration load during operation Tested according to<br />

IEC 60068-2-6: 10 - 58 Hz:<br />

0.075 mm, 58 to 200 Hz: 10 m/s²<br />

(1 g) 3)<br />

Shock loading during operation Tested according to<br />

IEC 60068-2-27: 50 m/s² (5 g),<br />

30 ms, 100 shocks<br />

Relative humidity Tested according to<br />

IEC 60068-78, IEC 60068-2-30:<br />

5% to <strong>80</strong>% at 25 °C<br />

(no condensation)<br />

Maximum permissible installation 45° over vertical<br />

angle +/-<br />

Ambient temperature during 0 °C … +50 °C in maximum<br />

operation<br />

configuration<br />

Certifications & standards<br />

Approvals CE, cULus(508)<br />

EMC CE, FCC A, 55022A,<br />

EN 61000-6-4 2) 6AV7 885..<br />

, EN 61000-6-2


■ Technical specifications (continued)<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>577C<br />

6AV7 885-1 6AV7 885-0 6AV7 885-3 6AV7 885-2 6AV7 885-5<br />

Front panel 12" TFT Key 12" TFT Touch 15" TFT Key 15" TFT Touch 19" TFT Touch<br />

Display<br />

Resolution (W x H in pixels) <strong>80</strong>0 x 600 <strong>80</strong>0 x 600 1024 x 768 1024 x 768 12<strong>80</strong> x 1024<br />

MTBF of backlighting<br />

(at 25 °C)<br />

50000 h at 24 h<br />

continuous operation,<br />

temperaturedependent<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

50000 h at 24 h<br />

continuous operation,<br />

temperaturedependent<br />

50000 h at 24 h<br />

continuous operation,<br />

temperaturedependent<br />

50000 h at 24 h<br />

continuous operation,<br />

temperaturedependent<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

50000 h at 24 h<br />

continuous operation,<br />

temperaturedependent<br />

Type of operation<br />

Function keys Yes No Yes No No<br />

Alphanumeric keyboard Yes No Yes No No<br />

Touch screen<br />

(analog/resistive)<br />

No Yes No Yes Yes<br />

Mouse on the front<br />

Design<br />

Yes No Yes No No<br />

Centralized configuration Yes Yes Yes Yes Yes<br />

Distributed configuration<br />

Dimensions<br />

No No No No No<br />

Mounting dimensions in<br />

centralized configuration<br />

(W x H x D, without optical<br />

drive) in mm<br />

450 x 290 x 84 368 x 290 x 84 450 x 321 x 87 450 x 290 x 87 450 x 3<strong>80</strong> x 94<br />

Operator control unit<br />

(W x H) in mm<br />

400 x 310 (7 HU) 400 x 310 (7 HU) 483 x 310 (19", 7 HU) 483 x 310 (19", 7 HU) 483 x 400 (19", 9 HU)<br />

Weights<br />

General features<br />

8.0 kg 8.0 kg 9.0 kg 9.0 kg 11.5 kg<br />

Accessories Insertable strips for Touch protective Insertable strips for Touch protective Touch protective<br />

keyboard<br />

membranes<br />

keyboard<br />

membranes<br />

membranes<br />

Power loss in maximum<br />

configuration<br />

24 V DC: max. 55 W 24 V DC: max. 55 W 24 V DC: max. 57 W 24 V DC: max. 57 W 24 V DC: max. 84 W<br />

5/129<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>577C<br />

1<br />

1<br />

■ Ordering data Order No. Order No.<br />

Configuration<br />

Configuration (continued)<br />

SIMATIC HMI I<strong>PC</strong>577C D 6AV7 885 - 17 7777 - 7 7 7 7 SIMATIC HMI I<strong>PC</strong>577C D 6AV7 885 - 17 7 7 7 7 - 7 777<br />

Front Panels<br />

12" TFT Touch 0<br />

12" TFT Key 1<br />

15" TFT Touch 2<br />

15" TFT Key 3<br />

19" TFT Touch 5<br />

Main boards (processor with<br />

fieldbus interfaces)<br />

Celeron M 1.2 GHz, 1 MB cache,<br />

<strong>80</strong>0 MHz FSB<br />

- with PROFINET (Industrial<br />

A A<br />

Ethernet); 2x LAN 1 Gbit/s<br />

Core2 Solo 1.2 GHz,<br />

3 MB cache, <strong>80</strong>0 MHz FSB<br />

- with PROFINET (Industrial<br />

A D<br />

Ethernet), 2x LAN 1 Gbit/s<br />

- with PROFIBUS DP12/MPI<br />

A E<br />

(CP 5611-compatible), 2x LAN<br />

1 Gbit/s<br />

- with PROFINET (RT/IRT)<br />

A F<br />

3 ports, 1x LAN 1 Gbit/s<br />

Core2 Duo 1.86 GHz,<br />

6 MB cache, 1066 MHz FSB<br />

- with PROFINET (Industrial<br />

A K<br />

Ethernet), 2x LAN 1 Gbit/s<br />

- with PROFIBUS DP12/MPI<br />

A L<br />

(CP 5611-compatible), 2x LAN<br />

1 Gbit/s<br />

- with PROFINET (RT/IRT)<br />

A M<br />

3 ports, 1x LAN 1 Gbit/s<br />

RAM<br />

1 GB RAM, DDR3 1<br />

2 GB RAM, DDR3 2<br />

4 GB RAM, DDR3 3<br />

Second mass storage and/or<br />

drive (formatted without operating<br />

system)<br />

No second mass storage/drive 0<br />

DVD-RW drive 1<br />

HDD + DVD-RW drive 2<br />

SSD + DVD-RW drive 3<br />

SSD min. 32 GB<br />

6<br />

(Solid-State Drive)<br />

HDD min. 250 GB 8<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

1) Multi language means: GER/ENG/FR/IT/SP/CHIN traditional/CHIN<br />

simplified/Korean/Japanese<br />

5/130<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

First mass storage (formatted,<br />

optionally with operating system):<br />

Without 0<br />

HDD min. 250 GB (no, if 2nd<br />

1<br />

mass storage HDD or SSD)<br />

2GB CompactFlash 2<br />

4GB CompactFlash 3<br />

8GB CompactFlash 4<br />

Solid State Drive (no, if 2nd<br />

6<br />

mass storage HDD or SSD)<br />

Operating system (pre-installed<br />

on first mass storage)<br />

Without operating system A<br />

Windows Embedded Standard<br />

B<br />

2009<br />

Windows XP Professional<br />

multi language 1)<br />

D<br />

Windows Embedded Standard 7 E<br />

Windows 7 Ultimate<br />

multi language 1)<br />

G<br />

Expansion (software)<br />

Without expansion A<br />

I<strong>PC</strong> DiagMonitor V4.2 enclosed B<br />

I<strong>PC</strong> Image & Partition Creator C<br />

I<strong>PC</strong> DiagMonitor V4.2 and<br />

D<br />

Image & Partition Creator V3.1<br />

enclosed<br />

Power supply<br />

100/240 V AC industrial power<br />

1<br />

supply with Namur<br />

100/240 V AC industrial power<br />

2<br />

supply with Namur; power cable<br />

for Europe<br />

100/240 V AC industrial power<br />

3<br />

supply with Namur; power cable<br />

for the USA<br />

100/240 V AC industrial power<br />

4<br />

supply with Namur; CN power<br />

cable<br />

100/240 V AC industrial power<br />

5<br />

supply with Namur; IT power<br />

cable<br />

100/240 V AC industrial power<br />

6<br />

supply with Namur; CH cable<br />

100/240 V AC industrial power<br />

7<br />

supply with Namur; UK cable<br />

24 V DC industrial power supply 8<br />

Note:<br />

Software Packages with SIMATIC WinCC flexible,<br />

SIMATIC WinCC and SIMATIC WinAC RTX (F) can be ordered<br />

together with the SIMATIC I<strong>PC</strong> with a price advantage.<br />

More information under "Embedded Bundles / Packages for<br />

industrial <strong>PC</strong>s".


<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>577C<br />

■ Ordering data Order No. Order No.<br />

Accessories<br />

SIMATIC I<strong>PC</strong> Image & Partition D 6ES7 648-6AA03-1YA0<br />

Protective film for SIMATIC HMI<br />

Creator V3.1<br />

I<strong>PC</strong>577C,<br />

Software tool for preventive data<br />

set of 10<br />

backup and hard disk partitioning<br />

For protecting the touch screen<br />

against dirt/scratches<br />

for SIMATIC I<strong>PC</strong>s, incl. manual on<br />

CD-ROM (German, English).<br />

for 12" Touch 6AV7 671-2BA00-0AA0<br />

SIMATIC I<strong>PC</strong> USB FlashDrive A 6ES7 648-0DC50-0AA0<br />

for 15" Touch 6AV7 671-4BA00-0AA0<br />

8 GB, USB 2.0; metal enclosure,<br />

for 19" Touch 6AV7 672-1CE00-0AA0<br />

bootable<br />

Labeling strips for Key devices 6AV7 672-0DA00-0AA0<br />

SIMATIC I<strong>PC</strong> Service USB B 6AV7 672-8JD01-0AA0<br />

For labeling soft keys and<br />

FlashDrive<br />

function keys, blank, supplied in<br />

8 GB, USB 2.0; metal enclosure,<br />

sets of 10<br />

bootable, Image & Partition<br />

Touch pen 6AV7 672-1JB00-0AA0<br />

Creator pre-installed, incl. CD<br />

Captive pen for operation of the<br />

touch devices, mounting of the<br />

SINUMERIK disk drive 3.5",<br />

USB 1.1<br />

6FC5 235-0AA05-1AA2<br />

support on the control cabinet<br />

with 1 m connecting cable<br />

Expansion components<br />

Industrial USB Hub 4 A 6AV6 671-3AH00-0AX0<br />

SIMATIC I<strong>PC</strong> DiagMonitor V4.2 B 6ES7 648-6CA04-2YX0<br />

4x USB 2.0 interfaces, IP65 for<br />

Software tool for monitoring<br />

SIMATIC I<strong>PC</strong>s, incl. manual, on<br />

mounting on control cabinet door<br />

or on standard mounting rail<br />

CD-ROM (German/English)<br />

Communication components<br />

<strong>PC</strong>I interface card<br />

with COM1, COM2 and LPT interfaces<br />

A 6ES7 648-2CA01-0AA0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/131<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>577C<br />

■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical specifications.<br />

10.5<br />

104.4<br />

310.3<br />

235<br />

SIMATIC HMI I<strong>PC</strong>577C 12" Key version<br />

10.5<br />

104.4<br />

310.3<br />

SIMATIC HMI I<strong>PC</strong>577C 12" Touch version<br />

5/132<br />

354.4<br />

400<br />

482.6<br />

465<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

70.8<br />

288.3 83.8<br />

288.3<br />

229<br />

229<br />

55.6<br />

48.7<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00402<br />

G_<strong>ST</strong><strong>80</strong>_XX_00403<br />

354.8<br />

10.5<br />

103.4<br />

235<br />

482.6<br />

SIMATIC HMI I<strong>PC</strong>577C 15" Key version<br />

10.5<br />

108.2<br />

310.3<br />

235<br />

465<br />

328<br />

482.6<br />

465<br />

SIMATIC HMI I<strong>PC</strong>577C 15" Touch version<br />

82.8<br />

87.6<br />

319.4<br />

229<br />

71.2<br />

288.3<br />

229<br />

55.6<br />

G_<strong>ST</strong><strong>80</strong>_XX_00404<br />

G_<strong>ST</strong><strong>80</strong>_XX_00405


■ Dimensional drawings (continued)<br />

10.5<br />

114.6<br />

400<br />

235<br />

354.4<br />

483<br />

465<br />

SIMATIC HMI I<strong>PC</strong>577C 19" Touch version<br />

94<br />

378<br />

229<br />

102.4<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00406<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>577C<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-panel-pc<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/133<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>677C<br />

■ Overview<br />

SIMATIC HMI I<strong>PC</strong>677C<br />

<strong>PC</strong> platform with high degree of industrial compatibility for<br />

demanding tasks in the area of <strong>PC</strong>-based automation.<br />

Rugged construction:<br />

The <strong>PC</strong> is resistant to the harshest mechanical stress and is<br />

reliable in operation.<br />

Compact design<br />

High degree of investment protection<br />

Fast integration capability<br />

Front panel versions:<br />

- 12", 15" and 19" TFT Touch<br />

- 12" and 15" TFT Keys<br />

- 15" TFT Touch INOX with stainless steel front for special<br />

requirements, e. g. in food, beverages and tobacco industries<br />

5/134<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Excellent industrial compatibility due to rugged construction,<br />

even when subjected to extreme vibration and shock<br />

High degree of investment protection thanks to assured<br />

availability of spare parts (for a period of 5 years following the<br />

end of active marketing)<br />

Excellent continuity of components for machine concepts with<br />

a long service life without any new engineering costs<br />

Savings in time and costs due to service-friendly equipment<br />

construction:<br />

- Operator control unit and computer unit can be opened<br />

easily for fast replacement of components or subsequent<br />

expansions<br />

- Front and rear USB 2.0 interfaces for quick and easy<br />

connection of additional hardware components<br />

High degree of industrial functionality thanks to integrated<br />

PROFIBUS DP/MPI or PROFINET (CP 1616-compatible)<br />

and 2 Gigabit Ethernet interfaces<br />

2 x ≥ 250 GB SATA hard disk system (configured as singledisk<br />

system or RAID1)<br />

32 GB SSD as rugged and high-speed hard disk substitute<br />

Reduction in standstill times thanks to high system availability<br />

Minimized energy consumption thanks to support for Wake-<br />

On-LAN, shutdown or dimming of the display during operation<br />

and use of Notebook components<br />

Efficient self-diagnostics (SIMATIC I<strong>PC</strong> DiagMonitor or<br />

DiagBase):<br />

Solutions for preventive data backup<br />

Integrated component of Totally Integrated Automation (TIA):<br />

increases productivity, minimizes the engineering outlay,<br />

reduces the lifecycle costs<br />

■ Application<br />

The SIMATIC HMI I<strong>PC</strong>677C is designed for use direct on-site at<br />

the machine. Due to the minimal mounting depth of 105/130 mm,<br />

it can also be used in confined spaces.<br />

The <strong>PC</strong> is used both in manufacturing automation and process<br />

automation, installed in control cabinets and consoles,<br />

19" cabinets/racks and swing arms (booms).<br />

Thanks to the Dual Core CPUs with Intel Core technology, highperformance<br />

control and visualization are possible simultaneously.<br />

With <strong>PC</strong>Ie (x16), the new <strong>PC</strong>I Express cards (x1, x4 and x8) are<br />

also supported.<br />

The integrated NVRAM (battery-backed) is supported by<br />

WinAC RTX with DC or AC power supply, devices with<br />

PROFIBUS or PROFINET (IRT capability) are equipped with this.<br />

A SIMATIC HMI I<strong>PC</strong> is the ideal platform for <strong>PC</strong>-based<br />

automation:<br />

<strong>PC</strong>-based visualization at the machine level on-site with<br />

SIMATIC WinCC flexible<br />

Complex solutions with SIMATIC WinCC process visualization<br />

<strong>PC</strong>-based Control with SIMATIC WinAC RTX Software PLC<br />

<strong>Siemens</strong> offers the complete modular system of harmonically<br />

matched automation components.<br />

The SIMATIC HMI l<strong>PC</strong>s can be ordered in conjunction with<br />

WinCC flexible or WinCC as SIMATIC HMI packages at a price<br />

advantage (see SIMATIC HMI complete systems).


■ Design<br />

The SIMATIC HMI I<strong>PC</strong>677C comprises a computer unit and an<br />

operator control unit.<br />

Components of the computer unit:<br />

Rugged metal enclosure, resistant to vibrations and shocks,<br />

with high electromagnetic compatibility<br />

Processor:<br />

- Intel Celeron 1.86 GHz , 2 cores<br />

- Intel Core i3 2.13 GHz, 2 cores, hyper-threading<br />

- Intel Core i7 2.53 GHz, 2 cores, hyper-threading, turbo boost<br />

Main memory basic configuration: 1 GB<br />

3.5" SATA hard disk: ≥ 250 Gbyte;<br />

the special vibration-absorbing hard disk support ensures<br />

reliable operation even under extreme mechanical stress<br />

Graphics integrated on CPU (Intel Graphics Media<br />

Accelerator)<br />

Interfaces:<br />

- 2 x 10/100/1000 Ethernet<br />

- PROFIBUS DP/MPI on board, floating<br />

- PROFINET (IRT-capable), 3-port, switching-enabled,<br />

CP 1616-compatible<br />

- 4 x USB 2.0 connection<br />

- 1 x serial V.24 (9-pin)<br />

Retentive memory:<br />

- 2 MB NVRAM, can be used with WinAC RTX 128 KB<br />

(AC and DC versions)<br />

Free slots for expansions:<br />

- 2 x <strong>PC</strong>I (slots with card retainer)<br />

- 1 x slot for CompactFlash card<br />

Power supply: 110/230 V AC (autorange), 50/60 Hz or 24 V DC<br />

DVI-I interface for connecting a further monitor (DVI or VGA)<br />

or Flat Panel monitor<br />

Optional additional components:<br />

Main memory expansion to 2, 3, or 4 GB, or 2 or 4 GB with<br />

ECC<br />

SATA hard disk ≥ 500 GB<br />

Dual hard disk module 2 x ≥ 250 GB SATA as single disk<br />

configuration or RAID1 preconfigured<br />

32 GB SSD (Solid-State Drive)<br />

Internal CF card slot (unpopulated, instead of hard disks)<br />

DVD±RW±R combo drive<br />

1 x <strong>PC</strong>Ie x16 / 1 x <strong>PC</strong>I instead of 2 x <strong>PC</strong>I slots (with card<br />

retainers)<br />

Different Microsoft Windows operating systems incl.<br />

Windows 7 Ultimate<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>677C<br />

Components of the operator control unit:<br />

The operator control units are available in the following versions:<br />

12" Key<br />

12.1" TFT color display, <strong>80</strong>0 x 600 pixels (SVGA)<br />

Membrane keyboard with international <strong>PC</strong> character set and<br />

36 additional function keys with LED and an integrated mouse<br />

12" Touch<br />

12.1" TFT color display, <strong>80</strong>0 x 600 pixels (SVGA)<br />

Resistive analog touch screen<br />

15" Key<br />

15.1" TFT color display, 1024 x 768 pixels (XGA)<br />

Membrane keyboard with international <strong>PC</strong> character set and<br />

36 additional function keys with LED and an integrated mouse<br />

15" Touch<br />

15.1" TFT color display, 1024 x 768 pixels (XGA)<br />

Resistive analog touch screen<br />

15" Touch, stainless steel/INOX<br />

15.1" TFT color display, 1024 x 768 (XGA)<br />

Resistive analog touch screen<br />

Stainless steel front, designed for use in the food and<br />

beverages industry<br />

Developed on the basis of EN 1672-2<br />

Polished surface (stainless steel 1.4301, line pattern,<br />

grain-size 240)<br />

IP66k on front<br />

Without USB front interface<br />

Display shattering protection<br />

Optimized frame profile, so that liquids can run off<br />

Minimal number of grooves and joints<br />

Decorative membrane tested against chemicals in<br />

accordance with DIN 42115, Part 2<br />

Mounting with clamping frame only; sealing material food-safe<br />

(EDPM, in accordance with FDA 21 CFR 177.2006)<br />

Prepared for EHEDG certification for the entire machine<br />

19" Touch<br />

19.1" TFT color display, 12<strong>80</strong> x 1024 pixels (SXGA)<br />

Resistive analog touch screen<br />

The operator control units feature a USB 2.0 port on the front for<br />

connecting external I/O devices, such as a mouse or keyboard.<br />

They fulfill the requirements of degree of protection IP65 and<br />

NEMA 4. All operator control units are also available without a<br />

USB port on the front.<br />

The computer unit is connected via a connecting cable attached<br />

at the rear of the operator control unit.<br />

Distributed configuration<br />

A distributed configuration can be set up with the SIMATIC Box<br />

I<strong>PC</strong>627C and the SIMATIC Flat Panel monitors. The monitor can<br />

be placed up to 30m away while retaining the front functionality<br />

(incl. rear USB interfaces). The Flat Panel monitors are available<br />

in different versions as a device without operating functionality,<br />

with touch or key operation.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/135<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>677C<br />

■ Design (continued)<br />

Expansion components<br />

SIMATIC I<strong>PC</strong> DiagMonitor<br />

<strong>PC</strong> diagnostics/alarm software for early detection and<br />

diagnosis of <strong>PC</strong> problems<br />

Comprehensive monitoring of temperature, fans, hard disks<br />

(SMART), watchdog, BIOS battery<br />

Operating hours counter for preventive maintenance<br />

Integrated log functions, comprehensive text messages,<br />

online help (German/English)<br />

Network-wide monitoring via SNMP and O<strong>PC</strong> interface<br />

possible<br />

Integrated Web server for monitoring over the network using a<br />

Web browser<br />

SIMATIC I<strong>PC</strong> Image & Partition Creator<br />

Software tool for preventive data back-up of the contents of<br />

bulk storage (CF cards, hard disks)<br />

High-speed restoring of system and data partitions with bit<br />

accuracy; user software and special installations are also<br />

backed up<br />

SIMATIC I<strong>PC</strong> Service USB FlashDrive<br />

Software tool for adaptation of mass storage partitioning<br />

Mobile memory medium for backing up/restoring mass<br />

memories<br />

Pre-installed Image & Partition Creator V3.0<br />

Ultra-compact and rugged<br />

SIMATIC I<strong>PC</strong> USB FlashDrive<br />

Mobile memory medium for SIMATIC <strong>PC</strong>/PG<br />

Fast data transfer (USB 2.0) and high memory capacity<br />

Ultra-compact and rugged<br />

Industrial USB Hub 4<br />

USB I/O can be connected and operated without opening the<br />

control cabinet door using the Industrial Hub 4.<br />

Industry-standard USB 2.0 hub, front IP65<br />

Mounting in control cabinet door or on DIN rail<br />

Inspection window and LEDs for each of the four interfaces<br />

Note:<br />

For further information, see "Expansion components".<br />

5/136<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Function<br />

Diagnosis<br />

integrated, parameterizable monitoring functions (program<br />

execution (watchdog), internal enclosure temperature, fan<br />

speed, BIOS battery voltage)<br />

Expanded diagnostics/messages via Ethernet, e-mail, text<br />

message and for direct routing into SIMATIC software via O<strong>PC</strong><br />

(optionally via SIMATIC I<strong>PC</strong> DiagMonitor)<br />

RAID1 for automatic data mirroring on two SATA hard disks<br />

■ Integration<br />

Integrated interfaces:<br />

Ethernet<br />

The integrated Ethernet interfaces (10/100/1000 Mbit/s) can<br />

be used for IT communication and for data exchange with<br />

PLCs such as SIMATIC S7 (with "SOFTNET S7" software<br />

packages).<br />

PROFIBUS<br />

The isolated PROFIBUS interface (12 Mbit/s) can be used for<br />

connecting distributed field devices or for coupling to<br />

SIMATIC S7 (with "SOFTNET for PROFIBUS" software<br />

package).<br />

PROFINET<br />

The three (IRT-enabled) PROFINET ports can be used to<br />

connect distributed I/O, SIMATIC S7 and drives. The<br />

switching-enabled ports of the CP 1616-compatible<br />

PROFINET option support linear bus and tree topologies<br />

(WinAC RTX from Version 2008). Alternatively, the interface<br />

can be used as a standard Windows interface.<br />

Other interfaces<br />

Two free slots for <strong>PC</strong>I modules or alternatively 1x <strong>PC</strong>I and<br />

1x <strong>PC</strong>Ie x16 (incl. x1, x4 or x8) modules, one Compact Flash<br />

card interface, 5 USB 2.0 interfaces (Universal Serial Bus) and<br />

one serial interface are available for connecting further I/O<br />

devices.


■ Technical specifications<br />

6AV7 89.-…<br />

General features<br />

Processor Intel Core i7-610E<br />

(2C/4T, 2.53 GHz, 4 MB L2,<br />

Turbo Boost, VT-d)<br />

Intel Core i3-330E<br />

(2C/4T,<br />

2.13 GHz, 3 MB L2)<br />

Intel Celeron P4505 (2C/2T,<br />

1.86 GHz, 2 MB L2)<br />

Main memory 1 GB, optional 2 GB or 4 GB or<br />

2 GB or 4 GB with ECC<br />

Free slots for expansions 2 x <strong>PC</strong>I (slot with card retainer) or<br />

1 x <strong>PC</strong>I and 1 x <strong>PC</strong>Ie x16<br />

1 x slot for CompactFlash Card<br />

(accessible from outside)<br />

Operating system Different Windows operating<br />

systems incl. Windows 7 Ultimate<br />

Power supply 24 V DC or 110/240 V AC<br />

(autorange), 50/60 Hz<br />

MTBF backlighting Typ. 50 000 h<br />

(at 24 h continuous operation,<br />

temperature-dependent)<br />

Drives<br />

Floppy drive Optional via external USB floppy<br />

drive<br />

Optical drives Optional DVD±RW±R combo<br />

drive, at the rear, operable from<br />

the side<br />

Hard disk/mass storage 3.5" SATA hard disk ≥ 250 GB;<br />

optional 3.5" SATA hard disk<br />

≥ 500 GB,<br />

dual hard disk module 2 x<br />

≥ 250 GB SATA as single disk<br />

configuration or RAID1 preconfigured,<br />

32 GB SSD<br />

(Solid-State Drive)<br />

Interfaces<br />

Graphic interface DVI-I for additional display unit:<br />

Color depth 32 bits<br />

Connection for keyboard/mouse USB / USB<br />

Serial interface COM1: 1 x V.24 (RS232)<br />

PROFIBUS DP/MPI Onboard, isolated, max.<br />

12 Mbit/s, compatible with<br />

CP 5611, not upgradeable<br />

PROFINET (IRT) Onboard, 3 x RJ 45, CP 1616compatible,<br />

not upgradeable<br />

PROFINET (IE), Ethernet Onboard, 2 x 10/100/1000 Mbit<br />

USB 1 x on front, 4 x on rear, USB 2.0<br />

(500 mA)<br />

Audio Possible via USB (external)<br />

Multimedia No<br />

1) 61000-6-2 replaces 50082-2; 61000-6-4 replaces 50081-2<br />

2) Valid with CF or SSD; with HDD: 5 g/0.5 g<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>677C<br />

Monitoring functions<br />

Temperature Yes<br />

Watchdog Yes<br />

Ambient conditions<br />

Degree of protection IP65 (front) in accordance with<br />

EN 60529 and NEMA 4<br />

Vibration load during operation Tested according to DIN IEC<br />

60068-2-6: 10-58 Hz:<br />

0.075 mm, 58 to 500 Hz:<br />

10 m/s² (1 g) 2)<br />

Shock loading during operation Tested according to DIN IEC<br />

60068-2-27: 50 m/s² (5 g), 30 ms,<br />

100 shocks<br />

EMC CE, FCC A, 55022A,<br />

EN 61000-6-4 1) 6AV7 89.-…<br />

, EN 61000-6-2<br />

Ambient temperature during 12"/15": 5 °C … +50 °C in<br />

operation<br />

maximum configuration<br />

19": 5 °C … +45 °C in maximum<br />

configuration<br />

Relative humidity Tested according to DIN IEC<br />

60068-78, DIN IEC 60068-2-30:<br />

5% to <strong>80</strong>% at 25 °C<br />

(no condensation)<br />

Maximum permissible installation 20° over vertical<br />

angle +/-<br />

Certifications & standards<br />

Approvals CE, cULus(508)<br />

Expansion components Uninterruptible power supply<br />

(UPS),<br />

SIMATIC NET communication<br />

modules,<br />

SIMATIC <strong>PC</strong> DiagMonitor,<br />

SIMATIC I<strong>PC</strong> Image & Partition<br />

Creator,<br />

USB disk drive 3.5",<br />

SIMATIC I<strong>PC</strong> USB FlashDrive<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/137<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>677C<br />

1<br />

1 1<br />

■ Ordering data Order No. Order No.<br />

Configuration<br />

Configuration<br />

(job-oriented production and<br />

delivery)<br />

SIMATIC HMI I<strong>PC</strong>677C D 6AV7 897 - 17 7 777 - 7 777<br />

SIMATIC HMI I<strong>PC</strong>677C D 6AV7 89 17 - 17 77 7 7 - 7 7 7 7<br />

Main memory<br />

Front panels<br />

12" TFT Touch 0<br />

1 GB DDR3<br />

2 GB DDR3<br />

0<br />

1<br />

12" TFT Key<br />

15" TFT Touch<br />

15" TFT Key<br />

19" TFT Touch<br />

1<br />

2<br />

3<br />

4<br />

3 GB DDR3<br />

4 GB DDR3<br />

2 GB DDR3 with ECC<br />

2<br />

3<br />

5<br />

Front options<br />

4 GB DDR3 with ECC<br />

6<br />

With front USB interface 0<br />

Mass storage<br />

Without front USB interface<br />

INOX front, without front USB,<br />

with 15" TFT Touch only<br />

3<br />

1<br />

2<br />

250 GB SATA hard disk<br />

500 GB SATA hard disk<br />

0<br />

1<br />

19" TFT Touch with Atex 22<br />

and UL Class 1 Division 2<br />

certification<br />

4 3<br />

RAID1 dual hard disk module<br />

2 x 250 GB SATA, preconfigured<br />

2<br />

Power supply<br />

24 V DC A<br />

Dual hard disk module<br />

2 x 250 GB SATA<br />

3<br />

110/230 V AC,<br />

power cable for Europe<br />

110/230 V AC,<br />

without power cable<br />

110/230 V AC,<br />

power cable for UK<br />

110/230 V AC,<br />

power cable for CH<br />

110/230 V AC,<br />

B<br />

C<br />

D<br />

E<br />

F<br />

32 GB SSD<br />

Second CF card slot, internal,<br />

empty (not with Windows XP or<br />

Windows 7) instead of hard<br />

disk or SSD<br />

Without mass memory<br />

Optical drives<br />

4<br />

5<br />

8<br />

power cable for the USA<br />

Without 0<br />

110/230 V AC,<br />

power cable for Italy<br />

G<br />

DVD±RW±R combo drive<br />

1<br />

110/230 V AC,<br />

H<br />

Communication interfaces<br />

power cable for China<br />

2x <strong>PC</strong>I free A<br />

Processor<br />

Intel Celeron 1.86 GHz (2 MB<br />

shared cache), 2 cores<br />

Intel Celeron 1.86 GHz<br />

A<br />

B<br />

1x <strong>PC</strong>I, 1x <strong>PC</strong>Ie (x16) free<br />

Operating system (preinstalled<br />

and activated)<br />

B<br />

(2 MB shared cache),<br />

2 cores, PROFIBUS MPI,<br />

2 MB buffered SRAM<br />

Intel Celeron 1.86 GHz<br />

(2 MB shared cache),<br />

2 cores, PROFINET MPI (3x<br />

C<br />

Without operating system<br />

Windows XP Professional multi<br />

language<br />

A 0<br />

RJ45, CP 1616-compatible),<br />

2 MB buffered SRAM<br />

Intel Core i3, 2.13 GHz (3 MB<br />

D<br />

shared cache), 2 cores, hyperthreading<br />

Intel Core i3, 2.13 GHz (3 MB<br />

shared cache), 2 cores, hyper-<br />

E<br />

threading, PROFIBUS MPI,<br />

2 MB buffered SRAM<br />

Intel Core i3, 2.13 GHz (3 MB<br />

shared cache), 2 cores, hyperthreading,<br />

PROFINET (3x<br />

RJ45, CP 1616-compatible),<br />

2 MB buffered SRAM<br />

F<br />

Intel Core i7, 2.53 GHz<br />

(4 MB shared cache), 2 cores,<br />

G<br />

hyper-threading, turbo boost<br />

Intel Core i7, 2.53 GHz<br />

(4 MB shared cache), 2 cores,<br />

H<br />

1)<br />

2)<br />

Multi language means: GER/ENG/FR/IT/SP/CHIN<br />

Only without RAID 1 option<br />

hyper-threading, turbo boost,<br />

PROFIBUS MPI, 2 MB buffered<br />

SRAM<br />

Note:<br />

Software Packages with SIMATIC WinCC flexible,<br />

Intel Core i7, 2.53 GHz<br />

(4 MB shared cache), 2 cores,<br />

J<br />

SIMATIC WinCC and SIMATIC WinAC RTX (F) can be ordered<br />

together with the SIMATIC I<strong>PC</strong> with a price advantage.<br />

hyper-threading, turbo boost,<br />

PROFINET (3 x RJ45,<br />

CP 1616-compatible), 2 MB<br />

buffered SRAM<br />

More information under "Embedded Bundles / Packages for<br />

industrial <strong>PC</strong>s".<br />

1)<br />

Windows 7 Ultimate multi<br />

language<br />

B 0<br />

1)<br />

C 0<br />

Windows Embedded Standard<br />

on 8 GB CF card 2)<br />

D 0<br />

Software extension<br />

Without<br />

SIMATIC I<strong>PC</strong> DiagMonitor V4.2<br />

0<br />

1<br />

enclosed<br />

SIMATIC I<strong>PC</strong> Image & Partition<br />

Creator V3.1 enclosed<br />

SIMATIC I<strong>PC</strong> DiagMonitor<br />

V4.2, Image & Partition Creator<br />

V3.1 enclosed<br />

2<br />

3<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

5/138<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>677C<br />

■ Ordering data Order No. Order No.<br />

I<strong>PC</strong>677C stock versions<br />

Non-heating apparatus cable<br />

12" TFT Touch D 6AV7 890-0BE00-1AB0<br />

for SIMATIC Box and Panel <strong>PC</strong><br />

with Windows XP Prof. MUI,<br />

110/230 V AC power supply,<br />

Core i3 2.13 GHz, 2 x <strong>PC</strong>I<br />

1 GB RAM, 250 GB HDD<br />

DVD±R/RW burner<br />

SIMATIC <strong>PC</strong> power cable,<br />

230 V AC, angled, 3 m,<br />

for:<br />

Germany<br />

United Kingdom<br />

6ES7 900-1AA00-0XA0<br />

6ES7 900-1BA00-0XA0<br />

PROFIBUS/MPI, NVRAM<br />

Switzerland 6ES7 900-1CA00-0XA0<br />

12" TFT Key<br />

with Windows XP Prof. MUI,<br />

110/230 V AC power supply,<br />

D 6AV7 891-0BE00-1AB0<br />

USA<br />

Italy<br />

China<br />

6ES7 900-1DA00-0XA0<br />

6ES7 900-1EA00-0XA0<br />

6ES7 900-1FA00-0XA0<br />

Core i3 2.13 GHz, 2 x <strong>PC</strong>I<br />

1 GB RAM, 250 GB HDD<br />

DVD±R/RW burner<br />

PROFIBUS/MPI, NVRAM<br />

15" TFT Touch<br />

with Windows XP Prof. MUI,<br />

110/230 V AC power supply,<br />

D 6AV7 892-0BE00-1AB0<br />

Touch pen<br />

Captive pen for operation of the<br />

touch devices, mounting of the<br />

support on the control cabinet<br />

Expansion components<br />

SIMATIC I<strong>PC</strong> DiagMonitor V4.2<br />

A<br />

B<br />

6AV7 672-1JB00-0AA0<br />

6ES7 648-6CA04-2YX0<br />

Core i3 2.13 GHz, 2 x <strong>PC</strong>I<br />

1 GB RAM, 250 GB HDD<br />

DVD±R/RW burner<br />

PROFIBUS/MPI, NVRAM<br />

15" TFT Key D 6AV7 893-0BE00-1AB0<br />

Software tool for monitoring<br />

SIMATIC I<strong>PC</strong>s, incl. manual, on<br />

CD-ROM (German/English)<br />

SIMATIC I<strong>PC</strong> Image & Partition D<br />

Creator V3.1<br />

6ES7 648-6AA03-1YA0<br />

with Windows XP Prof. MUI,<br />

110/230 V AC power supply,<br />

Core i3 2.13 GHz, 2 x <strong>PC</strong>I<br />

1 GB RAM, 250 GB HDD<br />

DVD±R/RW burner<br />

PROFIBUS/MPI, NVRAM<br />

Software tool for preventive data<br />

backup and hard disk partitioning<br />

for SIMATIC I<strong>PC</strong>s, incl. manual on<br />

CD-ROM (German, English)<br />

SIMATIC I<strong>PC</strong> USB FlashDrive A 6ES7 648-0DC50-0AA0<br />

19" TFT Touch<br />

with Windows XP Prof. MUI,<br />

110/230 V AC power supply,<br />

Core i3 2.13 GHz, 2 x <strong>PC</strong>I<br />

D 6AV7 894-0BE00-1AB0<br />

8 GB, USB 2.0, metal enclosure,<br />

bootable<br />

SIMATIC I<strong>PC</strong> Service USB<br />

FlashDrive<br />

B 6AV7 672-8JD01-0AA0<br />

1 GB RAM, 250 GB HDD<br />

DVD±R/RW burner<br />

PROFIBUS/MPI, NVRAM<br />

8 GB, USB 2.0; metal enclosure,<br />

bootable, Image & Partition<br />

Creator pre-installed, incl. CD<br />

Accessories<br />

Industrial USB Hub 4 A 6AV6 671-3AH00-0AX0<br />

Protective foil for Panel <strong>PC</strong> 477/<br />

577/677/Flat Panel,<br />

set of 10<br />

4 x USB 2.0 interfaces, IP65 for<br />

mounting on control cabinet door<br />

or DIN rail<br />

For protecting the touch screen<br />

against dirt/scratches<br />

Uninterruptible power supplies<br />

for 12" Touch<br />

for 15" Touch<br />

6AV7 671-2BA00-0AA0<br />

6AV7 671-4BA00-0AA0<br />

SITOP Power, 15 A DC UPS<br />

module with USB interface<br />

6EP1 931-2EC42<br />

for 19" Touch 6AV7 672-1CE00-0AA0<br />

with charger unit for 24 V lead<br />

Labeling strips for Panel<br />

<strong>PC</strong> 477/577/677 key devices<br />

battery,<br />

input 24 V DC/16 A,<br />

output 24 V DC/15 A<br />

For labeling soft keys and<br />

function keys, blank, supplied in<br />

sets of 10<br />

6AV7 672-0DA00-0AA0<br />

SITOP Power, battery module<br />

24 V/3.2 Ah<br />

6EP1 935-6MD11<br />

Memory expansion<br />

for DC UPS module 15 A<br />

1 GB DDR3 DIMM A 6ES7 648-2AJ40-0KA0<br />

Communication components<br />

2 GB DDR3 DIMM A 6ES7 648-2AJ50-0KA0<br />

<strong>PC</strong>I interface card<br />

1 GB DDR3 DIMM with ECC<br />

2 GB DDR3 DIMM with ECC<br />

A<br />

A<br />

6ES7 648-2AJ40-1KA0<br />

6ES7 648-2AJ50-1KA0<br />

With COM1, COM2 and LPT<br />

interfaces<br />

A 6ES7 648-2CA01-0AA0<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/139<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC HMI I<strong>PC</strong>677C<br />

■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical specifications.<br />

G<br />

H<br />

Operator control unit and overall device<br />

Installation cutout<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-panel-pc<br />

5/140<br />

J<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

K<br />

W<br />

W+1 (cutout)<br />

H+1 (cutout)<br />

K<br />

L<br />

N<br />

H<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

M<br />

G_<strong>ST</strong><strong>80</strong>_XX_00288<br />

G_<strong>ST</strong><strong>80</strong>_XX_00289<br />

Control units <strong>PC</strong> 677<br />

G<br />

Touch devices<br />

H J K L M N<br />

12" 289 271 141 11 53 369 71<br />

15" 289 271 138 11 24 367 42<br />

19"<br />

Key devices<br />

378 271 147 11 18 376 36<br />

12" 289 271 122 11 42 351 59<br />

15" 324 271 141 11 31 370 48<br />

Front dimensions Installation cutout<br />

W H W+1 H+1 D<br />

Touch devices<br />

12" 400 310 368 290 51<br />

15" 483 310 450 290 55<br />

19"<br />

Key devices<br />

483 400 450 3<strong>80</strong> 57<br />

12" 483 310 450 290<br />

15" 483 355 450 3211) 1) In addition: Two cutouts 25 x 5 mm on the top for keyboard slide-in<br />

label channels.<br />

Note:<br />

All dimensions without screw clearances.<br />

Note:<br />

Do you need a specific modification or option for the products<br />

described here? Under "Customized products", you will find<br />

information about additional sector-specific products that can<br />

be ordered as well as about options for customer-specific<br />

modification and adaptation.


■ Overview<br />

Panel <strong>PC</strong> 677B<br />

<strong>PC</strong> platform with high degree of industrial compatibility for<br />

demanding tasks in the area of <strong>PC</strong>-based automation.<br />

Rugged construction:<br />

The <strong>PC</strong> is resistant to the harshest mechanical stress and is<br />

reliable in operation.<br />

Compact design<br />

High degree of investment protection<br />

Fast integration capability<br />

Front panel versions:<br />

- 12", 15" and 19" TFT Touch<br />

- 12“ and 15“ TFT Keys<br />

- 15" TFT Touch INOX with stainless steel front for special<br />

requirements, e. g. in food, beverages and tobacco industries<br />

The operator control unit and computing unit can be placed<br />

30 m apart (optional).<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC Panel <strong>PC</strong> 677B<br />

Excellent industrial compatibility due to rugged construction,<br />

even when subjected to extreme vibration and shock<br />

High level of investment security thanks to assured spare<br />

parts availability of the components (for 5 years following the<br />

end of active marketing)<br />

Excellent continuity of components for machine concepts with<br />

a long service life without any new engineering costs<br />

Savings in time and costs due to service-friendly equipment<br />

construction:<br />

- Operator control unit and computer unit can be simply<br />

hinged open for fast replacement of components or for future<br />

expansion<br />

- USB 2.0 interfaces on the front and rear for quick and easy<br />

connection of additional hardware components<br />

High degree of industrial functionality thanks to integrated<br />

PROFIBUS DP/MPI or PROFINET interfaces<br />

(CP 1616-compatible) and 2 GB Ethernet interfaces<br />

Operational reliability<br />

Using the optional direct control key module, the process can<br />

be operated without delay over PROFIBUS DP independently<br />

of the operating system<br />

2 x ≥ 250 GB SATA hard disk system (configured as a single<br />

disk system or RAID1)<br />

Reduction in standstill times thanks to high system availability<br />

Efficient self-diagnostics (SIMATIC I<strong>PC</strong> DiagMonitor):<br />

- Solutions for preventative data security<br />

integrated component of Totally Integrated Automation (TIA):<br />

- Enhanced productivity, reduction of engineering costs,<br />

reduction of lifecycle costs<br />

- Spatially separated configuration of computer and operator<br />

control unit possible with the Remote Kit (up to 30 m,<br />

optionally available as accessories)<br />

■ Application<br />

SIMATIC Panel <strong>PC</strong> 677B is designed for use directly at the<br />

machine. Due to the minimal mounting depth of only<br />

105/130 mm, it can also be used in confined spaces.<br />

The <strong>PC</strong> can be used in production automation as well as in<br />

process automation and can be mounted in control cabinets,<br />

control desks, 19" cabinets/racks and in swing arms (booms).<br />

The Dual Core CPUs with Intel Core2 Duo technology support<br />

simultaneously high performance control and visualization.<br />

With <strong>PC</strong>Ie (x4), the new <strong>PC</strong>I express (<strong>PC</strong>Ie) cards (x1 and x4) are<br />

also supported.<br />

The integrated NVRAM (battery-backed) is supported from<br />

WinAC RTX 2005 SP2 and with DC power supply.<br />

A SIMATIC Panel <strong>PC</strong> is the ideal platform for <strong>PC</strong> based<br />

automation:<br />

<strong>PC</strong> based visualization on site at the machine with<br />

SIMATIC WinCC flexible<br />

Complex solutions with SIMATIC WinCC process visualization<br />

<strong>PC</strong>-based control with SIMATIC WinAC Software PLC<br />

<strong>Siemens</strong> offers the complete set of building blocks of automation<br />

components that are designed to interact perfectly.<br />

The SIMATIC Panel <strong>PC</strong>s can be ordered in combination with<br />

WinCC flexible or WinCC as SIMATIC HMI packages at a lower<br />

price (see SIMATIC HMI complete systems).<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/141<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC Panel <strong>PC</strong> 677B<br />

■ Design<br />

The Panel <strong>PC</strong> 677B comprises a computer unit and an operator<br />

control unit.<br />

Components of the computer unit:<br />

Rugged metal enclosure, resistant to vibrations and shocks,<br />

with high electromagnetic compatibility<br />

Processor:<br />

- Mobile Intel 945G chip set<br />

- Intel Celeron M 440/1.86 GHz or<br />

- Intel Core2 Duo T5500/Dual Core, 1.66 GHz or<br />

- Intel Core2 Duo T7400/Dual Core, 2.16 GHz<br />

Main memory basic configuration: 1 GB<br />

3.5" SATA hard disk: ≥ 160 GB;<br />

the special vibration-absorbing hard disk support ensures<br />

reliable operation even under extreme mechanical stress<br />

Onboard graphics<br />

Interfaces:<br />

- 2 x 10/100/1000 Ethernet<br />

- PROFIBUS DP/MPI on board, floating<br />

- PROFINET (IRT-capable), 3-port, switching-enabled,<br />

CP 1616-compatible<br />

- 4 x USB 2.0 connection<br />

- 1 x serial V.24 (9-pin)<br />

Retentive memory:<br />

- 2 MB NVRAM, can be used with WinAC RTX 128 KB<br />

(DC versions)<br />

Free slots for expansions:<br />

- 2 x <strong>PC</strong>I (slots with card retainer)<br />

- 1 x slot for CompactFlash card<br />

Power supply: 110/230 V AC (autorange), 50/60 Hz or 24 V DC<br />

DVI-I interface for connecting a further monitor (DVI or VGA)<br />

or Flat Panel<br />

Optional additional components:<br />

Main memory expansion to 2, 3 or 4 GB<br />

SATA hard disk ≥ 250 GB<br />

Dual hard disk module 2 x ≥ 250 GB SATA preconfigured as<br />

single disk configuration or RAID1<br />

Internal CF card slot (empty, instead of hard disks and optical<br />

drive; only with Windows XP embedded operating system)<br />

DVD±RW±R combo drive<br />

1 x <strong>PC</strong>Ie x 4 / 1 x <strong>PC</strong>I instead of 2 x <strong>PC</strong>I slots (with card<br />

retainers)<br />

Direct key module (for devices with key front)<br />

5/142<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Components of the operator control unit:<br />

The operator control units are available in the following versions:<br />

12" Key<br />

12.1" TFT color display, <strong>80</strong>0 x 600 pixels (SVGA)<br />

Membrane keyboard with international <strong>PC</strong> character set and<br />

36 additional function keys with LED and an integrated mouse<br />

12" Touch<br />

12.1" TFT color display, <strong>80</strong>0 x 600 pixels (SVGA)<br />

Resistive analog touch screen<br />

15" Key<br />

15.1" TFT color display, 1024 x 768 pixels (XGA)<br />

Membrane keyboard with international <strong>PC</strong> character set and<br />

36 additional function keys with LED and an integrated mouse<br />

15" Touch<br />

15.1" TFT color display, 1024 x 768 pixels (XGA)<br />

Resistive analog touch screen<br />

19" Touch<br />

19.1" TFT color display, 12<strong>80</strong> x 1024 pixels (SXGA)<br />

Resistive analog touch screen<br />

The operator control units feature a USB 2.0 port on the front for<br />

connecting external I/O devices, such as a mouse or keyboard.<br />

They fulfill the requirements of degree of protection IP65 and<br />

NEMA 4. All operator control units are also available without a<br />

USB port on the front.<br />

The computer unit is connected via a connecting cable attached<br />

at the rear of the operator control unit.


■ Design (continued)<br />

Expansion components<br />

SIMATIC I<strong>PC</strong> DiagMonitor<br />

<strong>PC</strong> diagnostics/alarm software for the early detection and<br />

diagnosis of <strong>PC</strong> problems<br />

Comprehensive monitoring of temperature, fans, hard disks<br />

(SMART), watchdog, BIOS battery<br />

Operating hours counter for preventive maintenance<br />

Integrated log functions, comprehensive text messages,<br />

online help (English/German)<br />

Network-wide monitoring via SNMP and O<strong>PC</strong> interface<br />

possible<br />

Integrated Web server for monitoring over the network using a<br />

Web browser<br />

SIMATIC I<strong>PC</strong> Image & Partition Creator<br />

Software tool for preventive data back-up of the contents of<br />

bulk storage (CF cards, hard disks)<br />

High-speed restoring of system and data partitions with bit<br />

accuracy; user software and special installations are also<br />

backed up<br />

Software tool for adaptation of mass storage partitioning<br />

SIMATIC I<strong>PC</strong> USB FlashDrive<br />

Mobile memory medium for SIMATIC <strong>PC</strong>/PG<br />

Fast data transfer (USB 2.0) and high memory capacity<br />

Ultra-compact and rugged<br />

SIMATIC I<strong>PC</strong> Service USB FlashDrive<br />

Mobile memory medium for backing up/restoring mass<br />

memories<br />

Pre-installed Image & Partition Creator V3.1<br />

Ultra-compact and rugged<br />

SIMATIC Panel <strong>PC</strong> Remote Kit<br />

Spatially separated configuration of computer and operator<br />

control unit<br />

At a maximum distance of up to 30 m<br />

Pure hardware solution, no need to install additional software<br />

Maintaining the Panel <strong>PC</strong> front functionality<br />

Additional USB interface on the rear<br />

Centralized and distributed configuration with only one basic<br />

unit<br />

Can be retrofitted<br />

Industrial USB Hub 4<br />

USB I/O can be connected and operated without opening the<br />

control cabinet door using the Industrial Hub 4.<br />

Industry-standard USB 2.0 Hub, Front IP65<br />

Installation in control cabinet door or on DIN rail<br />

Inspection window and LEDs for each of the four interfaces<br />

Note:<br />

For further information, see "Expansion components"<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Function<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC Panel <strong>PC</strong> 677B<br />

Diagnosis<br />

Integrated, parameterizable monitoring functions (program<br />

execution (watchdog), temperature inside housing, fan<br />

speed)<br />

Expanded diagnostics/alarms over Ethernet, by e-mail, as text<br />

message, and for direct infeed in SIMATIC software over O<strong>PC</strong><br />

(optionally through SIMATIC I<strong>PC</strong> DiagMonitor)<br />

RAID1 for automatic data mirroring on two SATA hard disks<br />

■ Integration<br />

Integrated interfaces:<br />

Ethernet<br />

The integrated Ethernet interfaces (10/100/1000 Mbit/s) can<br />

be used for IT communication and for exchanging data with<br />

programmable controllers such as SIMATIC S7 (with the<br />

"SOFTNET S7" software packages).<br />

PROFIBUS<br />

The floating PROFIBUS interface (12 Mbit/s) can be used for<br />

connecting distributed field devices or for coupling to<br />

SIMATIC S7 (with software package "SOFTNET for<br />

PROFIBUS").<br />

PROFINET<br />

The three (IRT-capable) PROFINET ports can be used to<br />

connect distributed I/O, SIMATIC S7 and drives. The<br />

switching-capable ports of the CP 1616-compatible<br />

PROFINET option support linear and tree topologies<br />

(WinAC RTX Version 2008 and higher). Alternatively, the<br />

interface can be used as a standard Windows interface.<br />

Further interfaces<br />

For connecting additional I/O devices, 2 spare slots are<br />

available for <strong>PC</strong>I modules or alternatively 1 x <strong>PC</strong>I and 1 x <strong>PC</strong>Ie<br />

x4 modules, as well as a Compact Flash Card interface, 5 USB<br />

2.0 interfaces (Universal Serial Bus) and one serial interface.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/143<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC Panel <strong>PC</strong> 677B<br />

■ Technical specifications<br />

SIMATIC Panel <strong>PC</strong> 677B 6AV7 870-.....-...0<br />

Supply voltage<br />

Supply voltage 100 V AC / 240 V AC (autorange)<br />

50/60 Hz; optional 24 V DC<br />

Memory<br />

Main memory 512 MB to 4 GB<br />

Data areas and their<br />

remanence<br />

Retentive data area in total<br />

(incl. times, counters, flags),<br />

max.<br />

5/144<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2 MB battery-backed only DC power<br />

supply WinAC RTX 2005 SP1 or<br />

higher<br />

Monitoring functions<br />

Temperature Yes<br />

Watchdog Yes<br />

Status LEDs yes<br />

Configuration<br />

SIMATIC Software Optionally in package with<br />

SIMATIC WinCC or WinCC flexible<br />

Ambient conditions<br />

Vibration load in operation Tested to IEC 68-2-6: 10 to<br />

58 Hz: 0.075 mm, 58 to 200 Hz:<br />

9.8 m/s2 (1 g)<br />

Shock loading in operation Tested to IEC 68-2-29: 50 m/s2 (5g),<br />

30 ms, 100 shocks<br />

Relative humidity Tested to IEC 68-2-3,<br />

IEC 68-2-30, IEC 68-2-56: 5% to <strong>80</strong>%<br />

at 25 °C<br />

(no condensation)<br />

Maximum permissible instal- 20°<br />

lation angle +/-<br />

Temperature<br />

Ambient temperature in<br />

operation<br />

12", 15": +5 °C to +50 °C in maximum<br />

configuration 15", 19":<br />

+5 °C to +45 °C in maximum<br />

configuration<br />

Degree of protection<br />

Front to EN 60529 IP65 (at the front) acc. to EN 60529<br />

and tested acc. to NEMA4<br />

Certifications & Standards<br />

Approval CE, cULus (508)<br />

EMC CE, EN 55011, EN 61000-6-4,<br />

EN 61000-6-2<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC Panel <strong>PC</strong> 677B 6AV7 870-.....-...0<br />

Interfaces<br />

Interfaces<br />

Free slots 2x <strong>PC</strong>I or 1x<strong>PC</strong>I & 1x <strong>PC</strong>Ie x4<br />

(slots with card retainer), 1x slot for<br />

Compact Flash Card<br />

Graphic interface DVI-I usable for additional display<br />

unit (VGA via adapter); color depth<br />

32 bits, 8 to 128 MB Shared Memory<br />

Connection for keyboard/ USB / USB<br />

mouse<br />

serial interface COM1: 1 x V.24 (RS232)<br />

PROFIBUS/MPI 1<br />

USB 1x at front, 4x at rear, USB 2.0<br />

(500 mA)<br />

Ethernet onboard, 2 x 10/100/1000 Mbit/s,<br />

RJ45, no plug-in card necessary<br />

Operating systems<br />

Operating system Windows 2000 Prof. (Multi Language),<br />

Windows XP Prof. (Multi Language),<br />

Windows Vista Ultimate 32 bit,<br />

Windows Server 2003 Standard 32 bit<br />

(incl. 5 clients), Windows XP<br />

embedded (English) on CF card, opt.<br />

without operating system<br />

Additional info on operating<br />

system<br />

Multi Language: Windows 2000, XP:<br />

GER, ENG, IT, FR, SP, KOR, CHN<br />

(traditional), CHN (simplified), JPN<br />

Windows Vista and Server 2003:<br />

GER, ENG, IT, FR, SP; further<br />

languages downloadable from<br />

Microsoft<br />

Processor<br />

Processor Intel Core 2 Duo technology; Intel<br />

Celeron M 440, 1.86 GHz, 533 MHz<br />

FSB, 1 MB SLC; Core 2 Duo T5500,<br />

1.66 GHz, 667 MHz FSB, 2 MB SLC;<br />

Core 2 Duo T7400, 2.16 GHz,<br />

667 MHz FSB, 4 MB SLC<br />

Drives<br />

Diskette drive optional: via external USB floppy disk<br />

drive<br />

Optical drives Optional: DVD±R±RW combi drive;<br />

on rear, can be operated from side<br />

Hard disk/Mass storage 3.5" SATA hard disk ≥ <strong>80</strong> GB, optional<br />

≥ 160 GB, optional: 2 x 2.5" SATA<br />

hard disk module (≥ <strong>80</strong> GB), RAID 1<br />

controller onboard; all drives are<br />

vibration-damped


■ Technical specifications (continued)<br />

Product type<br />

designation<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC Panel <strong>PC</strong> 677B<br />

6AV7 870-.....-...0 6AV7 871-.....-...0 6AV7 872-.....-...0 6AV7 873-.....-...0 6AV7 875-.....-...0<br />

SIMATIC Panel <strong>PC</strong><br />

677B 12" Touch<br />

Operator control and<br />

monitoring<br />

Accessory components Touch protective foil,<br />

remote kit<br />

SIMATIC Panel <strong>PC</strong><br />

677B 12" Keyboard<br />

Slide-in keyboard<br />

labels, direct key<br />

module, remote kit<br />

SIMATIC Panel <strong>PC</strong><br />

677B 15" Touch<br />

Touch protective foil<br />

(not for Inox front),<br />

remote kit<br />

SIMATIC Panel <strong>PC</strong><br />

677B 15" Keyboard<br />

Slide-in keyboard<br />

labels, direct key<br />

module, remote kit<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC Panel <strong>PC</strong><br />

677B 19" Touch<br />

Touch cover foils,<br />

remote kit, fixing<br />

elements for screw<br />

mounting at the front<br />

General features<br />

Front panel 12" TFT Touch 12" TFT Key 15" TFT Touch 15" TFT Key 19" TFT touch display<br />

Display<br />

Expansion components Uninterruptible power<br />

supply (USP),<br />

SIMATIC NET communication<br />

modules<br />

Power loss in full<br />

configuration<br />

140 W max. (15 W<br />

included per slot)<br />

Uninterruptible power<br />

supply (USP),<br />

SIMATIC NET communication<br />

modules<br />

140 W max. (15 W<br />

included per slot)<br />

Uninterruptible power<br />

supply (USP),<br />

SIMATIC NET communication<br />

modules<br />

140 W max. (15 W<br />

included per slot)<br />

Uninterruptible power<br />

supply (USP),<br />

SIMATIC NET communication<br />

modules<br />

140 W max. (15 W<br />

included per slot)<br />

Uninterruptible power<br />

supply (UPS),<br />

SIMATIC NET communication<br />

modules,<br />

DiagMonitor, Image-<br />

Partition Creator<br />

163 W max. (15 W<br />

included per slot)<br />

Screen diagonal 12 in 12 in 15 in 15 in 19 in<br />

Resolution<br />

(WxH in pixel)<br />

<strong>80</strong>0 x 600 <strong>80</strong>0 x 600 1024 x 768 1024 x 768 12<strong>80</strong> x 1024<br />

Backlighting<br />

MTBF backlighting<br />

(at 25 °C)<br />

50000 h in 24 h<br />

permanent operation,<br />

temperaturedependent<br />

50000 h in 24 h<br />

permanent operation,<br />

temperaturedependent<br />

50000 h in 24 h<br />

permanent operation,<br />

temperaturedependent<br />

50000 h in 24 h<br />

permanent operation,<br />

temperaturedependent<br />

Operating mode<br />

Function keys No 36 with LEDs No 36 with LEDs No<br />

Mouse, at front<br />

Touch operation<br />

No yes<br />

Alphanumeric<br />

keyboard<br />

No Yes No<br />

Touch screen<br />

(analog/resistive)<br />

Design<br />

Yes No Yes No Yes<br />

central design Yes Yes Yes Yes Yes<br />

distributed design Yes Yes Yes; by means of<br />

remote kit<br />

Dimensions<br />

Mounting cutout/device<br />

depth (W x H)<br />

Install. dimensions,<br />

centralized design<br />

(W x H x D, without<br />

optical drive) in mm<br />

additional mounting<br />

depth (optical drive)<br />

Operator control unit<br />

(W x H) in mm<br />

Install. dimensions,<br />

operator panel with<br />

distributed design<br />

(W x H x D) in mm<br />

Install. dimensions,<br />

computer unit with<br />

distributed design<br />

(W x H x D) in mm<br />

Dimensions and<br />

weight<br />

Weight<br />

Panel <strong>PC</strong> in central<br />

design, approx.<br />

368x290 / 144<br />

(incl. optical drive)<br />

450x290 / 126<br />

(incl. optical drive)<br />

450x290 / 142<br />

(incl. optical drive)<br />

Yes; by means of<br />

remote kit<br />

450x321 / 145<br />

(incl. optical drive)<br />

50000 h in 24 h<br />

permanent operation,<br />

temperaturedependent<br />

Yes; by means of<br />

remote kit<br />

450x3<strong>80</strong> / 151<br />

(incl. optical drive)<br />

368x290x123 450x290x105 450x321x124 450x3<strong>80</strong>x130<br />

21 mm 21 mm 21 mm 21 mm<br />

400x310 (7 HU) 483x310 (19", 7 HU) 483x310 (19", 7 HU) 483x355 (19", 8 HU) 483x400 (19", 9 HU)<br />

368x290x87 450x290x69 450x290x85 450x321x89 450x3<strong>80</strong>x94<br />

298x301x100;<br />

(298x301x<strong>80</strong> without<br />

CD)<br />

298x301x100;<br />

(298x301x<strong>80</strong> without<br />

CD)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

298x301x100;<br />

(298x301x<strong>80</strong> without<br />

CD)<br />

298x301x100;<br />

(298x301x<strong>80</strong> without<br />

CD)<br />

13 kg 12 kg 14 kg 16 kg 17 kg<br />

298x301x100;<br />

(298x301x<strong>80</strong> without<br />

CD)<br />

5/145<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC Panel <strong>PC</strong> 677B<br />

■ Ordering data Order No. Order No.<br />

1 1<br />

Configuration<br />

(job-oriented production and<br />

delivery)<br />

SIMATIC Panel <strong>PC</strong> 677B D 6AV7 87 17 - 17 77 7 7 - 7 7 7 0<br />

Front panels<br />

12" TFT Touch 0<br />

12" TFT Key 1<br />

15" TFT Touch 2<br />

15" TFT Key 3<br />

19" TFT Touch 5<br />

Front options<br />

With front USB interface 0<br />

Without front USB interface 1<br />

INOX front, without front USB,<br />

with 15" TFT Touch only<br />

Power supply<br />

2 2<br />

24 V DC A<br />

110/230 V AC,<br />

power cable for Europe<br />

B<br />

110/230 V AC<br />

(without power cable)<br />

C<br />

110/230 V AC,<br />

power cable for UK<br />

D<br />

110/230 V AC,<br />

power cable for CH<br />

E<br />

110/230 V AC,<br />

power cable for the USA<br />

F<br />

110/230 V AC,<br />

power cable for Italy<br />

G<br />

110/230 V AC,<br />

power cable for China<br />

Processor<br />

H<br />

Intel Celeron M 440 / 1.86 GHz,<br />

533 MHz FSB, 1 MB SLC, slots<br />

(free): 2 x <strong>PC</strong>I<br />

A<br />

Intel Celeron M 440 / 1.86 GHz,<br />

533 MHz FSB, 1 MB SLC, slots<br />

(free): 1 x <strong>PC</strong>Ie x4 and<br />

1 x <strong>PC</strong>I<br />

B<br />

Intel Core2 Duo T5500 / Dual<br />

Core, 1.66 GHz, 677 MHz FSB,<br />

2 MB SLC, slots (free):<br />

2 x <strong>PC</strong>I<br />

C<br />

Intel Core2 Duo T5500 / Dual<br />

Core, 1.66 GHz, 677 MHz FSB,<br />

2 MB SLC, slots (free):<br />

1 x <strong>PC</strong>Ie x4 and 1 x <strong>PC</strong>I<br />

D<br />

Intel Core2 Duo T7400 / Dual<br />

Core, 2.16 GHz, 677 MHz FSB,<br />

4 MB SLC, slots (free):<br />

2 x <strong>PC</strong>I<br />

E<br />

Intel Core2 Duo T7400 / Dual<br />

Core, 2.16 GHz, 677 MHz FSB,<br />

4 MB SLC, slots (free):<br />

1 x <strong>PC</strong>Ie x4 and 1 x <strong>PC</strong>I<br />

F<br />

1) Multi language means: GER/ENG/FR/IT/SP/CHIN traditional/CHIN<br />

simplified/Korean/Japanese<br />

2) Not with internal second CF card slot<br />

3) Only without RAID 1 option<br />

4) Multi language means: GER/ENG/FR/IT/SP; other languages only by<br />

downloading from Microsoft<br />

5) Not with Windows 2000 Professional or Windows 2003 Server<br />

6) Only with Core2 Duo CPUs, not with PROFINET option<br />

5/146<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Configuration<br />

(continued)<br />

SIMATIC Panel <strong>PC</strong> 677B D 6AV7 877 - 117<br />

7 777 - 7 770<br />

Main memory<br />

1 GB DDR2 2<br />

2 GB DDR2 3<br />

3 GB DDR2 4<br />

4 GB DDR2 5<br />

Mass storage<br />

160 GB SATA hard disk 0<br />

250 GB SATA hard disk 1<br />

RAID1 dual hard disk module<br />

2<br />

2 x <strong>80</strong> GB SATA, preconfigured<br />

Dual hard disk module<br />

3<br />

2 x <strong>80</strong> GB SATA<br />

Second CF card slot (only in<br />

4<br />

combination with Windows XP<br />

embedded), internal, not fitted,<br />

only with version without opt.<br />

drive and without HDD<br />

Optical drives<br />

Without 0<br />

DVD±RW±R combo drive<br />

1<br />

Communication interfaces<br />

PROFIBUS/MPI; 2 x Gbit<br />

A<br />

Ethernet, 2 MB NVRAM<br />

PROFINET (3 x RJ45,<br />

CP 1616-compatible); 2 x Gbit<br />

Ethernet, 513 KB NVRAM 5)<br />

B<br />

Operating system (preinstalled<br />

and activated)<br />

Without operating system 2) A<br />

Windows 2000 Professional<br />

B<br />

multi language 1) 2) 3)<br />

Windows XP Professional<br />

C<br />

multi language SP2<br />

(SP3 enclosed) 1) 2)<br />

Windows Vista Ultimate multi<br />

language (SP1 enclosed) 2)<br />

D<br />

Windows Server 2003<br />

Standard Edition<br />

incl. 5 clients 6) MUI 4) E<br />

,<br />

SP1 (SP2 enclosed)<br />

Windows XP embedded<br />

(English) 3) F<br />

on 2 GB CF card<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

Note:<br />

Software Packages with SIMATIC WinCC flexible,<br />

SIMATIC WinCC and SIMATIC WinAC RTX (F) can be ordered<br />

together with the SIMATIC I<strong>PC</strong> with a price advantage.<br />

More information under "Embedded Bundles / Packages for<br />

industrial <strong>PC</strong>s".


© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC Panel <strong>PC</strong> 677B<br />

■ Ordering data Order No. Order No.<br />

Stock versions<br />

Expansion components<br />

12" TFT Touch D 6AV7 870-0BC20-1AC0<br />

SIMATIC I<strong>PC</strong> DiagMonitor V4.2 B 6ES7 648-6CA04-2YX0<br />

110/230 V AC power supply<br />

Software tool for monitoring<br />

Core2 Duo T5500, 1.66 GHz,<br />

SIMATIC I<strong>PC</strong>s, incl. manual, on<br />

2 x <strong>PC</strong>I<br />

CD-ROM (German/English)<br />

1 GB RAM, 160 GB HDD,<br />

DVD±R±RW burner<br />

PROFIBUS/MPI<br />

SIMATIC I<strong>PC</strong> Image & Partition D<br />

Creator V3.1<br />

6ES7 648-6AA03-1YA0<br />

Windows XP Prof. MUI (SP2)<br />

(Ger/F/I/SP/CHN traditional/CHN<br />

simplified/Korean/Japanese)<br />

Software tool for preventive data<br />

backup and hard disk partitioning<br />

for SIMATIC <strong>PC</strong>s, incl. manual on<br />

15" TFT Touch D 6AV7 872-0BC20-1AC0<br />

CD-ROM (German, English)<br />

110/230 V AC power supply<br />

SIMATIC I<strong>PC</strong> USB FlashDrive A 6ES7 648-0DC50-0AA0<br />

Core2 Duo T5500, 1.66 GHz,<br />

2 x <strong>PC</strong>I<br />

1 GB RAM, 160 GB HDD,<br />

DVD±R±RW burner<br />

PROFIBUS/MPI<br />

8 GB, USB 2.0; metal enclosure,<br />

bootable<br />

SIMATIC I<strong>PC</strong> Service USB<br />

FlashDrive<br />

B 6AV7 672-8JD01-0AA0<br />

Windows XP Prof. MUI (SP2)<br />

(Ger/F/I/SP/CHN traditional/CHN<br />

simplified/Korean/Japanese)<br />

15" TFT Key D 6AV7 873-0BC20-1AC0<br />

8 GB, USB 2.0; metal enclosure,<br />

bootable<br />

Image & Partition Creator V3.0<br />

ready-installed, incl. CD<br />

110/230 V AC power supply<br />

Core2 Duo T5500, 1.66 GHz,<br />

2 x <strong>PC</strong>I<br />

3.5" USB disk drive<br />

With 1 m connecting cable<br />

6FC5 235-0AA05-1AA2<br />

1 GB RAM, 160 GB HDD,<br />

DVD±R±RW burner<br />

SIMATIC Panel <strong>PC</strong> Remote Kit<br />

PROFIBUS/MPI<br />

Windows XP Prof. MUI (SP2)<br />

(Ger/F/I/SP/CHN traditional/CHN<br />

simplified/Korean/Japanese)<br />

for the separate configuration of<br />

control unit and computer unit<br />

24 V DC, 5 m<br />

24 V DC, 10 m<br />

A<br />

A<br />

6AV7 671-1EA00-5AA1<br />

6AV7 671-1EA01-0AA1<br />

19" TFT Touch D 6AV7 875-0BC20-1AC0<br />

24 V DC, 15 m A 6AV7 671-1EA01-5AA1<br />

110/230 V AC power supply<br />

24 V DC, 20 m A 6AV7 671-1EA02-0AA1<br />

Core2 Duo T5500, 1.66 GHz,<br />

24 V DC, 30 m A 6AV7 671-1EA03-0AA1<br />

2 x <strong>PC</strong>I<br />

1 GB RAM, 160 GB HDD,<br />

DVD±R±RW burner<br />

PROFIBUS/MPI<br />

Windows XP Prof. MUI (SP2)<br />

110/230 V AC, 5 m<br />

110/230 V AC, 10 m<br />

110/230 V AC, 15 m<br />

110/230 V AC, 20 m<br />

A<br />

A<br />

A<br />

A<br />

6AV7 671-1EA10-5AA1<br />

6AV7 671-1EA11-0AA1<br />

6AV7 671-1EA11-5AA1<br />

6AV7 671-1EA12-0AA1<br />

(Ger/F/I/SP/CHN traditional/CHN<br />

110/230 V AC, 30 m A 6AV7 671-1EA13-0AA1<br />

simplified/Korean/Japanese)<br />

Industrial USB Hub 4 A 6AV6 671-3AH00-0AX0<br />

Accessories<br />

4 x USB 2.0 interfaces, IP65 for<br />

Cover membrane for Panel<br />

mounting on control cabinet door<br />

<strong>PC</strong> 477/577/677(B)/Flat<br />

or DIN rail<br />

Panel, set of 10 each<br />

Uninterruptible power supplies<br />

For protecting the touch screen<br />

against dirt/scratches<br />

for 15" Touch<br />

Memory expansion<br />

1 GB DDR2 A<br />

6AV7 671-4BA00-0AA0<br />

6ES7 648-2AG40-0HA0<br />

SITOP Power, 15 A DC UPS<br />

module with USB interface<br />

with charger unit for 24 V lead<br />

battery,<br />

input 24 V DC/16 A,<br />

6EP1 931-2EC42<br />

2 GB DDR2 A 6ES7 648-2AG50-0HA0<br />

output 24 V DC/15 A<br />

Non-heating apparatus cable<br />

SITOP Power, battery module 6EP1 935-6MD11<br />

for SIMATIC Box and Panel <strong>PC</strong><br />

24 V/3.2 Ah<br />

SIMATIC <strong>PC</strong> power cable,<br />

for DC UPS module 15 A<br />

230 V AC, angled, 3 m,<br />

for:<br />

Communication components<br />

Germany 6ES7 900-1AA00-0XA0<br />

<strong>PC</strong>I interface card<br />

United Kingdom 6ES7 900-1BA00-0XA0<br />

With COM1, COM2 and LPT A 6ES7 648-2CA01-0AA0<br />

Switzerland 6ES7 900-1CA00-0XA0<br />

interfaces<br />

USA 6ES7 900-1DA00-0XA0<br />

Italy 6ES7 900-1EA00-0XA0<br />

China 6ES7 900-1FA00-0XA0<br />

Touch pen<br />

Captive pen for operation of the<br />

touch devices, mounting of the<br />

support on the control cabinet<br />

A 6AV7 672-1JB00-0AA0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/147<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

SIMATIC Panel <strong>PC</strong><br />

SIMATIC Panel <strong>PC</strong> 677B<br />

■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical specifications.<br />

G<br />

H<br />

Operating unit and complete unit<br />

Installation cutout<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-panel-pc<br />

5/148<br />

J<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

K<br />

W<br />

W+1 (cutout)<br />

H+1 (cutout)<br />

K<br />

L<br />

N<br />

H<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

M<br />

G_<strong>ST</strong><strong>80</strong>_XX_00288<br />

G_<strong>ST</strong><strong>80</strong>_XX_00289<br />

Control units<br />

<strong>PC</strong> 677<br />

G H J K L M N<br />

Touch devices<br />

12" 289 271 141 11 53 369 71<br />

15" 289 271 138 11 24 367 42<br />

19"<br />

Key devices<br />

378 271 147 11 18 376 36<br />

12" 289 271 122 11 42 351 59<br />

15" 324 271 141 11 31 370 48<br />

Front dimensions Installation cutout<br />

W H W+1 H+1 T<br />

Touch devices<br />

12" 400 310 368 290 51<br />

15" 483 310 450 290 55<br />

19"<br />

Key devices<br />

483 400 450 3<strong>80</strong> 57<br />

12" 483 310 450 290<br />

15" 483 355 450 3211) 1) In addition: Two cutouts 25 x 5 mm on the top for keyboard<br />

slide-in label channels<br />

Note:<br />

All dimensions without screw clearances.<br />

Note:<br />

Do you a require specific modification or extension to the<br />

products described here? Then refer to "Customized products",<br />

where you will find information about additional sector-specific<br />

products that can be ordered as well as about options for<br />

customer-specific modification and adaptation.


■ Overview<br />

<strong>Siemens</strong> has developed a wide range of matched hardware and<br />

software components for <strong>PC</strong>-based automation.<br />

Focal point: SIMATIC <strong>PC</strong>-based Control with SIMATIC WinAC,<br />

the open, flexible and reliable control for your <strong>PC</strong>-based<br />

automation solution.<br />

All automation tasks can be implemented on one platform on the<br />

<strong>PC</strong>, such as open-loop control, closed-loop control, operator<br />

control & monitoring and motion control. <strong>PC</strong>-based Automation<br />

is your first choice wherever <strong>PC</strong> applications have to be handled<br />

in addition to classic PLC tasks.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

<strong>PC</strong>-based Controller<br />

SIMATIC <strong>PC</strong>-based controllers<br />

SIMATIC <strong>PC</strong>-based Control<br />

Adds <strong>PC</strong>-based control to the SIMATIC S7 controller family<br />

Especially suitable where a variety of tasks such as data<br />

processing, communication, visualization, technology and<br />

control have to be integrated in one <strong>PC</strong>.<br />

Versions<br />

SIMATIC WinAC Software PLC<br />

for tasks requiring a high level of flexibility and integration<br />

capability.<br />

SIMATIC WinAC ODK<br />

allows <strong>PC</strong> solutions for technological tasks to be integrated<br />

flexibly and powerfully into the controller.<br />

Properties<br />

Runs on standard <strong>PC</strong>s under Windows XP Professional SP2.<br />

Code-compatible with SIMATIC S7:<br />

Programmed with SIMATIC industrial software, created<br />

programs can also be used for SIMATIC S7.<br />

Uses standard interfaces for integration into the office<br />

environment.<br />

Open interfaces for the integration of solution-specific<br />

technological hardware and software.<br />

■ Application<br />

SIMATIC WinAC is optimized for the following tasks:<br />

Compact design:<br />

Data processing, communication, visualization, technology<br />

and control must be integrated on one <strong>PC</strong> for space and<br />

performance reasons.<br />

Openness:<br />

High-performance integration into the data processing is<br />

required.<br />

Technology:<br />

Specific technological tasks must be executed in close<br />

corporation with the control functions.<br />

Flexibility:<br />

The task requires the integration of special hardware or<br />

software modules.<br />

SIMATIC WinAC is provided for this purpose with open and<br />

powerful interfaces. SIMATIC WinAC is therefore the ideal<br />

platform for tailored automation solutions.<br />

Further information can be found on the Internet at:<br />

www.siemens.com/pc-based-automation<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/149<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

<strong>PC</strong>-based Controller<br />

SIMATIC <strong>PC</strong>-based controllers<br />

■ Function<br />

Programming<br />

SIMATIC Software<br />

Interfacing to the process<br />

The <strong>PC</strong>-based controller is programmed and configured with<br />

SIMATIC WinAC software PLCs support access to the process <strong>ST</strong>EP 7 and the SIMATIC engineering tools for production<br />

I/O via PROFIBUS DP and PROFINET IO. The PROFIBUS or engineering. For this purpose, all SIMATIC programming<br />

PROFINET interface modules from the SIMATIC NET product languages are also available for WinAC.<br />

range and the integrated interfaces of the SIMATIC <strong>PC</strong> are used<br />

for this purpose.<br />

The SIMATIC programming languages fulfill the EN 6.1131-3<br />

standard. This minimizes the familiarization and training time.<br />

Technological tasks<br />

In addition, the program modules which were programmed for<br />

There are various ways of solving technological tasks with SIMATIC S7 controllers can be reused in WinAC.<br />

WinAC:<br />

<strong>ST</strong>EP 7 for all aspects of the control task:<br />

SIMATIC Runtime Software – this includes for example<br />

Standard PID Control or Easy Motion Control – provides a series<br />

Configuring of control and communication:<br />

of libraries for technological functions, which are directly<br />

All characteristics of the <strong>PC</strong>-based control and the interplay<br />

processed by SIMATIC WinAC.<br />

with additional SIMATIC components are handled by <strong>ST</strong>EP 7.<br />

All configuring data are centrally and consistently stored at a<br />

SIMATIC function modules such as FM 350 or FM 351 can be single location.<br />

used simultaneously in an ET200M station on PROFIBUS or<br />

PROFINET.<br />

A complete spectrum of programming languages:<br />

<strong>ST</strong>EP 7 and the <strong>ST</strong>EP 7 engineering tools offer a wide<br />

An open integration of specific technological tasks can be spectrum of programming languages for all aspects of control<br />

achieved by means of the WinAC ODK for the SIMATIC<br />

tasks.<br />

WinAC software and slot PLCs.<br />

Local and remote programming:<br />

The isochronous mode via PROFIBUS DP of WinAC RTX and The complete network connection of SIMATIC <strong>ST</strong>EP 7 allows<br />

WinAC Slot allows for exactly reproducible response times for both the local programming of WinAC on the same <strong>PC</strong> and<br />

and is the basis for precise and fast control applications. the remote programming over LAN or WAN.<br />

Communication<br />

Efficient debugging:<br />

<strong>ST</strong>EP 7 offers efficient support for the testing and<br />

SIMATIC WinAC supports SIMATIC communication both locally<br />

commissioning of the control programs. This includes for<br />

on the same <strong>PC</strong> and over the SIMATIC networks PROFIBUS and<br />

example online modification of programs, the display and<br />

Industrial Ethernet/PROFINET. The following communication<br />

control of variables or single-step processing.<br />

connections are possible:<br />

Programming and commissioning by means of <strong>ST</strong>EP 7 both SIMATIC iMap<br />

locally and remotely from a PG/<strong>PC</strong><br />

The actual control functionality of the <strong>PC</strong>-based controller is<br />

Visualization with WinCC or WinCC flexible either locally or programmed using <strong>ST</strong>EP 7.<br />

over a network<br />

The interconnection of system components and machine which<br />

Communication with other WinAC or S7 systems<br />

was generated with WinAC RTX and PROFINET CBA, is implemented<br />

with the open tool SIMATIC iMap.<br />

Open communication (TCP/UDP) via the PROFINET interface<br />

PROFINET CBA<br />

■ More information<br />

Interfacing to visualization<br />

Brochures<br />

The SIMATIC HMI products WinCC flexible and WinCC have full<br />

access to all data and functions of SIMATIC WinAC in accor-<br />

Information material for downloading can be found on the<br />

dance with the demands placed on Totally Integrated<br />

Internet:<br />

Automation. They can be operated both locally on the same <strong>PC</strong> www.siemens.com/simatic/printmaterial<br />

as SIMATIC WinAC and remotely over the supported networks.<br />

Even the SIMATIC Touch and Operator Panels cooperate with<br />

SIMATIC WinAC without any restrictions. In this case the access<br />

via the PROFIBUS DP or PROFINET IO interface of the SIMATIC<br />

WinAC is particularly useful, as this enables the devices to be<br />

operated "on site" with minimum wiring outlay.<br />

The SIMATIC NET O<strong>PC</strong> server, which is included in the delivery<br />

of WinAC, alternatively allows access to process data through<br />

commercially available visualization systems.<br />

Access to process data<br />

The SIMATIC NET O<strong>PC</strong> server offers an open access to process<br />

data through any O<strong>PC</strong> client application.<br />

In addition, access to process data from standard Windows<br />

applications such as Excel or Access can be carried out simply<br />

via the O<strong>PC</strong> Data Access Automation Interface.<br />

5/150<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Overview<br />

SIMATIC WinAC RTX:<br />

optimized for applications that require a high degree of<br />

flexibility and integration capability.<br />

The software solution for tasks that require hard deterministic<br />

behavior and high performance.<br />

With real-time expansion for assuring deterministic behavior<br />

for the control section.<br />

New with WinAC RTX 2010:<br />

Operation under Windows 7<br />

Web server<br />

New PROFINET functions:<br />

- Isochronous mode<br />

- Shared Device<br />

- Media redundancy<br />

- IP configuration<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

<strong>PC</strong>-based Automation<br />

<strong>PC</strong>-based Controller<br />

SIMATIC WinAC RTX<br />

Hard real time and maximum performance<br />

Implementation of fast, S7-compatible control solutions with<br />

low processor loading.<br />

Alongside the control task, sufficient processor capability is<br />

available for processing complex, demanding <strong>PC</strong><br />

applications in parallel.<br />

■ Application<br />

SIMATIC WinAC RTX is particularly suited to tasks that demand<br />

a high degree of flexibility and efficient integration in the overall<br />

task. This comprises close interlinking with data processing and<br />

logistics systems as well as interfacing with technology tasks<br />

such as motion control or vision systems.<br />

SIMATIC WinAC RTX is equally suited to implementation on costeffective<br />

<strong>PC</strong> platforms with single-core processors and on highend<br />

<strong>PC</strong>s, e. g. with QuadCore processors. WinAC RTX is<br />

optimized for operation on embedded <strong>PC</strong> platforms such as the<br />

S7-modular Embedded Controller, the SIMATIC I<strong>PC</strong>427C, or the<br />

SIMATIC HMI I<strong>PC</strong>477C. These platforms feature, with their<br />

diskless and fanless design, significantly enhanced ruggedness<br />

for an automation task. Non-volatile memory is also available<br />

which permits storage of up to 512 KB retentive data<br />

(S7-mEX, EC31) on a voltage dip, independently of the file<br />

system. The I/O is connected via the leading fieldbus standards<br />

of PROFINET or PROFIBUS. With the S7-mEC, EC31, operation<br />

is also possible in conjunction with centralized signal modules<br />

(SM) of S7-300. The support of the integrated PROFINET or<br />

PROFIBUS interfaces of the SIMATIC <strong>PC</strong>s as well as the<br />

excellent performance result in an excellent price/performance<br />

ratio for <strong>PC</strong>-based automation.<br />

The WinAC ODK is used for expansion of the PLC functionality<br />

with application specific C/C++ applications. It supports:<br />

integration of complex high-level language algorithms in the<br />

control program<br />

access to the Windows API or Windows system resources<br />

access to external hardware and software components.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/151<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

<strong>PC</strong>-based Controller<br />

SIMATIC WinAC RTX<br />

■ Design<br />

SIMATIC WinAC RTX comprises the following components:<br />

Windows Logic Controller (WinLC RTX V4.6)<br />

WinAC TimeSynchronization<br />

SIMATIC NET SOFTNET-S7 Lean incl. SIMATIC NET O<strong>PC</strong><br />

Real-time driver for PROFINET and PROFIBUS interfaces<br />

IntervalZero RTX real-time core for ensuring real-time and a<br />

deterministic response<br />

Optional:<br />

Interfaces for connection to PROFIBUS DP:<br />

- CP 5611 A2 or the integrated PROFIBUS interface of the<br />

SIMATIC I<strong>PC</strong><br />

- CP 5621<br />

- CP 5613 A2<br />

- CP 5603<br />

- CP 5623<br />

Interfaces for connection to PROFINET<br />

- CP 1616 (HW version 8 and above) or integrated CP 1616<br />

onboard interface of the SIMATIC <strong>PC</strong><br />

- CP 1604 (HW version 7 and above)<br />

- Integrated standard Ethernet interfaces of selected<br />

SIMATIC <strong>PC</strong>s (e. g. SIMATIC I<strong>PC</strong>427C, HMI I<strong>PC</strong>477C,<br />

I<strong>PC</strong>227D and HMI I<strong>PC</strong>277D)<br />

WinAC Open Development Kit (ODK):<br />

- For integrating C/C++ code in WinAC RTX<br />

- Integration of external software (technology programs) or <strong>PC</strong><br />

components (e. g. barcode scanner, <strong>PC</strong> cards for measured<br />

value acquisition)<br />

5/152<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Function<br />

Windows Logic Controller (WinLC RTX)<br />

The Windows Logic Controller handles the actual control task<br />

and execution of the control program. It coordinates the<br />

associated input and output of process values via the lower-level<br />

PROFINET or PROFIBUS fieldbus system and makes the<br />

process values available for visualization and data processing<br />

tasks.<br />

Several processing levels are available for optimum process<br />

control:<br />

Cyclic program processing.<br />

Interrupt processing.<br />

Time and date-controlled processing.<br />

Isochronous processing level with PROFIBUS or PROFINET.<br />

Retentivity<br />

WinAC RTX saves all data that has been declared as retentive<br />

on the hard disk upon exiting. An uninterruptible power supply<br />

(e. g. SITOP DC UPS) can be used to ensure a defined termination<br />

of the WinAC Software PLC even in the case of an<br />

unexpected drop in the <strong>PC</strong> power supply.<br />

Alternatively, storage of retentive data on the integrated, batterybacked<br />

SRAM memory of the SIMATIC <strong>PC</strong> (for example,<br />

SIMATIC I<strong>PC</strong>427C or SIMATIC HMI I<strong>PC</strong>) can also be selected so<br />

that up to 128 KB of data can be stored retentively on voltage<br />

failure. For operation on SIMATIC S7-mEC, EC31, as much as<br />

512 KB of retentive data can be stored on the integrated, nonvolatile<br />

memory. A UPS is not necessary in this case. It is,<br />

however, recommended that a UPS is used when supplementary<br />

applications such as visualization or data processing<br />

demand saving of the current data in the event of voltage failure.<br />

O<strong>PC</strong> server<br />

The SIMATIC NET O<strong>PC</strong> server supplied with WinAC provides<br />

open access to all process values. Visualization systems or data<br />

processing systems can be linked to WinAC via this interface.<br />

Interface to visualization<br />

SIMATIC WinAC RTX is easy to use with the SIMATIC HMI<br />

systems SIMATIC WinCC flexible or SIMATIC WinCC.<br />

Visualization systems from third-party suppliers can be<br />

connected via the included SIMATIC NET O<strong>PC</strong> server.<br />

Communication<br />

The programming of the Windows Logic Controller with <strong>ST</strong>EP 7<br />

and also the visualization with SIMATIC HMI can be implemented<br />

both locally in the same <strong>PC</strong> and remotely using the<br />

standard SIMATIC networks Industrial Ethernet/PROFINET or<br />

PROFIBUS.<br />

WinAC RTX can exchange data with WinAC stations or with<br />

S7 controllers over these networks. WinAC RTX supports Open<br />

User Communication over the PROFINET interface, which<br />

permits communication with any peers via the open protocols<br />

TCP, UDP, and now also ISOonTCP. In addition, access to the<br />

WinAC web server is also supported via this interface.<br />

A SOFTNET S7 Lean license is included for communication over<br />

Industrial Ethernet by means of the integrated Ethernet interfaces<br />

of the SIMATIC I<strong>PC</strong>.


■ Technical specifications<br />

6ES7 671-0RC08-0YA0<br />

Product type designation SIMATIC WinAC RTX 2010<br />

Product version<br />

Hardware product version -<br />

Firmware version V4.6<br />

Associated programming <strong>ST</strong>EP7 as of V5.5 + HW update /<br />

package<br />

iMap V3.0 SP1<br />

Memory<br />

Work memory<br />

integrated (for program) 4 Mbyte; Adjustable; depends on<br />

Non Paged Memory Pool<br />

integrated (for data) 4 Mbyte; Adjustable; depends on<br />

Non Paged Memory Pool<br />

Load memory<br />

integrated RAM, max. 8 Mbyte; Adjustable; depends on<br />

Non Paged Memory Pool<br />

CPU-blocks<br />

DB<br />

Number, max. 65 535; Limited only by RAM set<br />

for data<br />

Size, max. 64 Kibyte<br />

FB<br />

Number, max. 65 536; Limited only by RAM set<br />

for code<br />

Size, max. 64 Kibyte<br />

FC<br />

Number, max. 65 536; Limited only by RAM set<br />

for code<br />

Size, max. 64 Kibyte<br />

OB<br />

Size, max. 64 Kibyte<br />

Nesting depth<br />

per priority class 24<br />

additional within an error OB 24<br />

CPU processing times<br />

for bit operations, min. 0.004 µs; typ.<br />

for fixed point arithmetic, min. 0.003 µs; typ.<br />

for floating point arithmetic, min. 0.004 µs; typ.<br />

Reference platform Pentium IV, 2.4 GHz<br />

Counters, timers and their<br />

retentivity<br />

S7 counter<br />

Number 2048<br />

Retentivity<br />

- can be set Yes<br />

-lower limit 0<br />

- upper limit 2047<br />

-preset 8<br />

Counting range<br />

- can be set Yes<br />

-lower limit 0<br />

- upper limit 999<br />

IEC counter<br />

present Yes<br />

Type SFB<br />

Number Unlimited (limited only by RAM<br />

capacity)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

<strong>PC</strong>-based Controller<br />

SIMATIC WinAC RTX<br />

Product type designation<br />

S7 times<br />

6ES7 671-0RC08-0YA0<br />

SIMATIC WinAC RTX 2010<br />

Number<br />

Retentivity<br />

2048<br />

-can be set Yes<br />

-lower limit 0<br />

- upper limit 2047<br />

-preset<br />

Time range<br />

0<br />

-lower limit 10 ms<br />

- upper limit<br />

IEC timer<br />

9990s<br />

present Yes<br />

Type SFB<br />

Number Unlimited (limited only by RAM<br />

capacity)<br />

Data areas and their retentivity<br />

Retentivity without UPS and PS<br />

Extension Board<br />

128 KB with SIMATIC I<strong>PC</strong>427C and<br />

HMI I<strong>PC</strong>477C; further SIMATIC <strong>PC</strong>s<br />

on request<br />

Retentivity with UPS<br />

Flag<br />

all data<br />

Number, max. 16 Kibyte<br />

Retentivity preset MB 0 to MB 15<br />

Number of clock memories<br />

Data blocks<br />

8<br />

Retentivity adjustable Yes; via non-retain property on DB<br />

Retentivity preset<br />

Local data<br />

Yes<br />

adjustable, max. 64 Kibyte<br />

preset 32 Kibyte<br />

per priority class, max.<br />

Address area<br />

I/O address area<br />

61 440 byte<br />

Inputs 16 Kibyte<br />

Outputs<br />

of which, distributed<br />

16 Kibyte<br />

- DP interface, inputs 16 Kibyte<br />

- DP interface, outputs 16 Kibyte<br />

- PN interface, inputs 16 Kibyte<br />

- PN interface, outputs<br />

Process image<br />

16 Kibyte<br />

Inputs, adjustable 8Kibyte<br />

Outputs, adjustable 8Kibyte<br />

Inputs, default 512 byte<br />

Outputs, default<br />

Subprocess images<br />

512 byte<br />

Number of subprocess images,<br />

max.<br />

Digital channels<br />

15<br />

Inputs 128 000<br />

Outputs<br />

Analog channels<br />

128 000<br />

Inputs <strong>80</strong>00<br />

Outputs <strong>80</strong>00<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/153<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

<strong>PC</strong>-based Controller<br />

SIMATIC WinAC RTX<br />

■ Technical specifications (continued)<br />

6ES7 671-0RC08-0YA0<br />

Product type designation SIMATIC WinAC RTX 2010<br />

Hardware configuration<br />

Submodules<br />

Number of submodules, max 4<br />

of which PROFIBUS, max. 4; Supported interfaces: see 1st<br />

and 2nd interface<br />

of which Industrial Ethernet,<br />

max.<br />

5/154<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

1; Supported interfaces: see 3rd<br />

and 4th interface<br />

Number of operable FMs and<br />

CPs (recommended)<br />

FM FM distributed: FM 350-1 / 350-2,<br />

FM 351, FM 352, FM 353, FM 355 /<br />

355-2<br />

CP, point-to-point 2; CP 340, CP 341 distributed<br />

CP, LAN<br />

Time of day<br />

Clock<br />

Over <strong>PC</strong> CP<br />

Hardware clock<br />

(real-time clock)<br />

Yes<br />

battery-backed and synchronizable<br />

Runtime meter<br />

Yes<br />

Number<br />

Clock synchronization<br />

8<br />

supported Yes<br />

to <strong>PC</strong>-CP, slave Yes<br />

on Ethernet via NTP<br />

1st interface<br />

Yes<br />

Type of interface CP 5611-A2, CP 5621, integrated<br />

PB interface of the SIMATIC <strong>PC</strong><br />

Max. no. of simultaneously<br />

operable CPs<br />

1<br />

Physics RS 485 / PROFIBUS<br />

Isolated Yes<br />

Number of connection resources<br />

Functionality<br />

8<br />

MPI No<br />

DP master Yes<br />

DP slave<br />

DP master<br />

No<br />

Number of connections, max.<br />

Services<br />

8<br />

- PG/OP communication Yes<br />

- Global data communication No<br />

- S7 basic communication No<br />

- S7 communication Yes<br />

- S7 communication, as client Yes<br />

- S7 communication, as server Yes<br />

- Equidistance mode support Yes; Only in conjunction with<br />

isochronous mode<br />

- Isochronous mode Yes<br />

- SYNC/FREEZE Yes<br />

- Activation/deactivation of DP<br />

slaves<br />

Yes<br />

- Direct data exchange (slaveto-slave<br />

communication)<br />

Yes<br />

- DPV1 Yes<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Product type designation<br />

DP master<br />

6ES7 671-0RC08-0YA0<br />

SIMATIC WinAC RTX 2010<br />

Transmission rate, max. 12 Mbit/s<br />

Number of DP slaves, max.<br />

Address area<br />

64<br />

- Inputs, max. 16 Kibyte<br />

-Outputs, max.<br />

User data per DP slave<br />

16 Kibyte<br />

- Inputs, max. 244 byte<br />

-Outputs, max.<br />

2nd interface<br />

244 byte<br />

Type of interface CP 5613, CP 5613-A2, CP 5603<br />

Max. no. of simultaneously<br />

operable CPs<br />

4<br />

Physics RS 485 / PROFIBUS<br />

Isolated<br />

Functionality<br />

Yes<br />

MPI No<br />

DP master Yes<br />

DP slave<br />

DP master<br />

No<br />

Number of connections, max.<br />

Services<br />

50<br />

- PG/OP communication Yes<br />

- Global data communication No<br />

- S7 basic communication No<br />

- S7 communication Yes<br />

- S7 communication, as client Yes<br />

- S7 communication, as server Yes<br />

- Equidistance mode support Yes; Only in conjunction with<br />

isochronous mode<br />

- Isochronous mode Yes<br />

- SYNC/FREEZE Yes<br />

- Activation/deactivation of DP<br />

slaves<br />

Yes<br />

- Direct data exchange (slaveto-slave<br />

communication)<br />

Yes<br />

- DPV1 Yes<br />

Transmission rate, max. 12 Mbit/s<br />

Number of DP slaves, max.<br />

Address area<br />

125<br />

- Inputs, max. 16 Kibyte<br />

-Outputs, max.<br />

User data per DP slave<br />

16 Kibyte<br />

- Inputs, max. 244 byte<br />

-Outputs, max. 244 byte


■ Technical specifications (continued)<br />

6ES7 671-0RC08-0YA0<br />

Product type designation SIMATIC WinAC RTX 2010<br />

3rd interface<br />

Type of interface PROFINET<br />

Max. no. of simultaneously<br />

operable CPs<br />

1; Intel Pro/1000 (Intel 82571EB,<br />

82573L, 82574L, 82541PI; nonshared<br />

IRQ required); integrated IE<br />

interface SIMATIC <strong>PC</strong> 4x7B, 6x7B,<br />

8x7B, I<strong>PC</strong>4x7C, I<strong>PC</strong>6x7C, I<strong>PC</strong>8x7C<br />

Physics Ethernet<br />

Isolated Yes<br />

Integrated switch No<br />

Number of ports 1<br />

automatic detection of transmission<br />

speed<br />

Yes; 10/100 Mbit/s<br />

Autonegotiation Yes<br />

Autocrossing<br />

Media redundancy<br />

Yes<br />

supported<br />

Functionality<br />

No<br />

PROFINET IO Controller Yes<br />

PROFINET IO Device No<br />

PROFINET CBA<br />

PROFINET IO Controller<br />

Services<br />

Yes<br />

- PG/OP communication Yes<br />

- S7 communication Yes<br />

- Isochronous mode No<br />

- Open IE communication Yes<br />

Transmission rate, min. 100 Mbit/s<br />

Transmission rate, max. 100 Mbit/s<br />

Max. number of connectable IO<br />

devices for RT<br />

128<br />

- of which in line, max. 128<br />

IRT, supported No<br />

Prioritized startup supported Yes<br />

- Number of IO Devices, max. 32<br />

Activation/deactivation of IO<br />

Devices<br />

Yes<br />

- Number of IO Devices that can<br />

be simultaneously activated/<br />

deactivated, max.<br />

8<br />

IO Devices changing during<br />

operation (partner ports),<br />

supported<br />

Yes<br />

Device replacement without<br />

swap medium<br />

Yes<br />

Send clock times 1 ms<br />

Updating time 1 - 512 ms (minimum value<br />

depends on communication share<br />

set for PROFINET I/O, on the<br />

number of I/O devices, and on the<br />

volume of configured user data)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

<strong>PC</strong>-based Controller<br />

SIMATIC WinAC RTX<br />

6ES7 671-0RC08-0YA0<br />

Product type designation SIMATIC WinAC RTX 2010<br />

PROFINET IO Controller<br />

Address area<br />

- Inputs, max. 16 Kibyte<br />

-Outputs, max. 16 Kibyte<br />

User data per address area, 2kbyte<br />

max.<br />

- User data consistency, max. 256 byte<br />

Open IE communication<br />

Open IE communication, Yes<br />

supported<br />

Number of connections, max. 32<br />

Local port numbers used at the<br />

system end<br />

Keep-alive function, supported<br />

4th interface<br />

Yes<br />

Type of interface PROFINET<br />

Max. no. of simultaneously<br />

operable CPs<br />

0, 20, 21, 23, 25, <strong>80</strong>, 102, 135, 161,<br />

<strong>80</strong><strong>80</strong>, 34962, 34963, 34964, 65532,<br />

65533, 65534, 65535<br />

1; CP 1616 (HW release 8 or<br />

above), CP 1604 (HW release 7 or<br />

higher), integrated PN interface of<br />

SIMATIC <strong>PC</strong> and S7-mEC<br />

Physics Ethernet<br />

Isolated Yes<br />

Integrated switch Yes<br />

Number of ports 3<br />

automatic detection of<br />

transmission speed<br />

Yes; 10/100 Mbit/s<br />

Autonegotiation Yes<br />

Autocrossing<br />

Media redundancy<br />

Yes<br />

supported Yes<br />

Switchover time on line break,<br />

typically<br />

200 ms<br />

Number of stations in the ring,<br />

max.<br />

50<br />

Change of IP address at runtime,<br />

supported<br />

Yes<br />

Number of connection resources<br />

Functionality<br />

32<br />

PROFINET IO Controller Yes<br />

PROFINET IO device No<br />

PROFINET CBA Yes<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/155<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

<strong>PC</strong>-based Controller<br />

SIMATIC WinAC RTX<br />

■ Technical specifications (continued)<br />

6ES7 671-0RC08-0YA0<br />

Product type designation SIMATIC WinAC RTX 2010<br />

PROFINET IO Controller<br />

Services<br />

- PG/OP communication Yes<br />

- S7 communication Yes<br />

- Isochronous mode Yes<br />

- Open IE communication Yes<br />

Transmission rate, max. 100 Mbit/s<br />

Max. number of connectable IO<br />

Devices for RT<br />

256<br />

- of which in line, max. 256<br />

Number of IO Devices with IRT<br />

and the option "high flexibility"<br />

64<br />

- of which in line, max. 32<br />

Number of IO Devices with IRT<br />

and the option "high performance",<br />

max.<br />

64<br />

- of which in line, max. 32<br />

IRT, supported Yes<br />

Prioritized startup supported Yes<br />

- Number of IO Devices, max. 32<br />

Activation/deactivation of IO<br />

Devices<br />

Yes<br />

- Number of IO Devices that can<br />

be simultaneously activated/<br />

deactivated, max.<br />

8<br />

IO Devices changing during<br />

operation (partner ports),<br />

supported<br />

Yes<br />

Device replacement without<br />

swap medium<br />

Yes<br />

Send clock times 250 µs, 500 µs, 1 ms<br />

Updating time<br />

Address area<br />

0.25...512 depending on the send<br />

cycle<br />

- Inputs, max. 16 Kibyte<br />

- Outputs, max. 16 Kibyte<br />

User data per address area,<br />

max.<br />

2kbyte<br />

- User data consistency, max. 256 byte<br />

5/156<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6ES7 671-0RC08-0YA0<br />

Product type designation SIMATIC WinAC RTX 2010<br />

Open IE communication<br />

Open IE communication, Yes<br />

supported<br />

Number of connections, max. 32<br />

Local port numbers used at the<br />

system end<br />

0, 20, 21, 25, <strong>80</strong>, 102, 135, 161,<br />

34962, 34963, 34964, 65532,<br />

65533, 65534, 65535<br />

Communication functions<br />

PG/OP communication Yes<br />

Data record routing<br />

Global data communication<br />

Yes; Only with CP 5611 or<br />

integrated PROFIBUS interface of<br />

the SIMATIC <strong>PC</strong><br />

supported<br />

S7 basic communication<br />

No<br />

supported<br />

S7 communication<br />

No<br />

supported Yes<br />

as server Yes<br />

as client Yes<br />

User data per job, max.<br />

Open IE communication<br />

64 Kibyte; When using BSEND/<br />

USEND<br />

TCP/IP Yes<br />

- Number of connections, max. 32<br />

- Data length for connection<br />

type 11H, max.<br />

65 534 byte<br />

- Data length, max. 65 534 byte<br />

ISO-on-TCP (RFC1006) Yes<br />

- Number of connections, max. 32<br />

- Data length, max. 65 534 byte<br />

UDP Yes<br />

- Number of connections, max. 32<br />

- Data length, max.<br />

Web server<br />

1472byte<br />

supported Yes<br />

Number of HTTP clients 2<br />

User-defined websites No


■ Technical specifications (continued)<br />

6ES7 671-0RC08-0YA0<br />

Product type designation SIMATIC WinAC RTX 2010<br />

PROFINET CBA (at set setpoint<br />

communication load)<br />

Setpoint for the CPU communication<br />

load<br />

Number of remote interconnection<br />

partners<br />

Number of functions, master/<br />

slave<br />

Total of all Master/Slave<br />

connections<br />

Data length of all incoming<br />

connections master/slave, max.<br />

Data length of all outgoing<br />

connections master/slave, max.<br />

Number of device-internal and<br />

PROFIBUS interconnections<br />

Data length of device-internal<br />

und PROFIBUS interconnections,<br />

max.<br />

Data length per connection,<br />

max.<br />

Remote interconnections with<br />

acyclic transmission<br />

- Sampling frequency:<br />

Sampling time, min.<br />

- Number of incoming interconnections<br />

- Number of outgoing interconnections<br />

- Data length of all incoming<br />

interconnections, max.<br />

- Data length of all outgoing<br />

interconnections, max.<br />

- Data length per connection,<br />

max.<br />

Remote interconnections with<br />

cyclic transmission<br />

- Transmission frequency:<br />

Transmission interval, min.<br />

- Number of incoming interconnections<br />

- Number of outgoing interconnections<br />

- Data length of all incoming<br />

interconnections, max.<br />

- Data length of all outgoing<br />

interconnections, max.<br />

- Data length per connection,<br />

max.<br />

20%<br />

64<br />

30<br />

1000<br />

6<strong>80</strong>0byte<br />

6<strong>80</strong>0byte<br />

500<br />

4000byte<br />

1400byte<br />

500 ms<br />

100<br />

100<br />

2000byte<br />

2000byte<br />

1400byte<br />

10 ms<br />

200<br />

200<br />

4<strong>80</strong>0byte<br />

4<strong>80</strong>0byte<br />

250 byte<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

<strong>PC</strong>-based Controller<br />

SIMATIC WinAC RTX<br />

6ES7 671-0RC08-0YA0<br />

Product type designation SIMATIC WinAC RTX 2010<br />

PROFINET CBA (at set setpoint<br />

communication load)<br />

HMI variables via PROFINET<br />

(acyclic)<br />

- Number of stations that can 3<br />

log on for HMI variables<br />

(PN O<strong>PC</strong>/iMap)<br />

- HMI variable updating 500 ms<br />

- Number of HMI variables 200<br />

- Data length of all HMI 2000byte<br />

variables, max.<br />

PROFIBUS proxy functionality<br />

- supported Yes<br />

- Number of linked PROFIBUS 16<br />

devices<br />

- Data length per connection, 240 byte; Slave-dependent<br />

max.<br />

Number of connections<br />

overall 96<br />

S7 message functions<br />

Number of login stations for 62<br />

message functions, max.<br />

SCAN procedure No<br />

Process diagnostic messages Yes; ALARM_S, ALARM_SQ,<br />

ALARM_D, ALARM_DQ<br />

simultaneously active Alarm-S 20; of a total of 20 for all SFCs<br />

blocks, max.<br />

Alarm 8-blocks Yes<br />

Number of instances for alarm 8 4000<br />

and S7 communication blocks,<br />

max.<br />

Process control messages No<br />

Test commissioning functions<br />

Status/control<br />

Status/control variable<br />

Forcing<br />

Yes<br />

Forcing No<br />

Status block Yes<br />

Single step Yes<br />

Number of breakpoints<br />

Diagnostic buffer<br />

20<br />

present Yes<br />

Number of entries, max. 3200<br />

-can be set Yes<br />

-preset 120<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/157<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

<strong>PC</strong>-based Controller<br />

SIMATIC WinAC RTX<br />

■ Technical specifications (continued)<br />

6ES7 671-0RC08-0YA0<br />

Product type designation SIMATIC WinAC RTX 2010<br />

Isochronous mode<br />

Isochronous mode Yes<br />

Number of DP masters with 2<br />

isochronous mode<br />

User data per isochronous slave, 128 byte<br />

max.<br />

equidistance Yes<br />

shortest clock pulse 2.2 ms; 2.2 ms without partial<br />

process image; 2.2 ms with partial<br />

process image<br />

Hardware requirements<br />

Hardware required <strong>PC</strong> with color monitor, keyboard,<br />

mouse or pointing device for<br />

Windows<br />

Required memory on hard disk, 100 Mbyte<br />

min.<br />

Main memory, min. 1Gbyte<br />

Processor Intel Celeron M, 900 MHz or<br />

compatible<br />

Multi-processor system Yes; Dual Pentium, CoreDuo,<br />

Core2Duo or compatible<br />

Hyper-threading Yes<br />

Operating systems<br />

Windows NT 4.0 No<br />

Windows 2000 No<br />

Windows XP Yes; Professional, SP2 and SP3<br />

Windows XP embedded Yes; With the delivery image of the<br />

SIMATIC <strong>PC</strong><br />

Supported HAL types under<br />

Windows XP<br />

5/158<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

ACPI uniprocessor <strong>PC</strong>, ACPI multiprocessor<br />

<strong>PC</strong>, MPS multiprocessor<br />

<strong>PC</strong><br />

Windows Vista No<br />

Windows embedded Standard 7 No<br />

Windows 7 Yes; Professional, Enterprise,<br />

Ultimate (only 32 bits)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6ES7 671-0RC08-0YA0<br />

Product type designation SIMATIC WinAC RTX 2010<br />

Configuration<br />

programming<br />

Programming language<br />

-LAD Yes<br />

-FBD Yes<br />

-<strong>ST</strong>L Yes<br />

-SCL Yes<br />

-CFC Yes<br />

- GRAPH Yes<br />

-HiGraph® Yes<br />

Nesting levels 8<br />

Software libraries<br />

- Easy Motion Control Yes<br />

Know-how protection<br />

User program protection/ Yes<br />

password protection<br />

Open Development interfaces<br />

CCX (Custom Code Extension) Yes; WinAC ODK V4.2 or higher<br />

CMI (Controller Management Yes; WinAC ODK V4.2 or higher<br />

Interface)<br />

SMX (Shared Memory<br />

Yes; WinAC ODK V4.2 or higher<br />

Extension)<br />

- Inputs 4Kibyte<br />

-Outputs 4Kibyte<br />

Dimensions and weight<br />

Weight<br />

Weight, approx. 100 g; with packaging


<strong>PC</strong>-based Automation<br />

<strong>PC</strong>-based Controller<br />

SIMATIC WinAC RTX<br />

■ Ordering data Order No. Order No.<br />

SIMATIC WinAC RTX 2010 B<br />

Software PLC for <strong>PC</strong>-based<br />

automation tasks with stringent<br />

deterministic requirements;<br />

PROFIBUS and PROFINET;<br />

CD-ROM with electronic<br />

documentation ge, e, f; single<br />

license, executable under<br />

Windows XP SP2 and SP3 as well<br />

as Windows 7 (32 bit)<br />

SIMATIC WinAC RTX 2010 B<br />

Upgrade<br />

6ES7 671-0RC08-0YA0<br />

6ES7 671-0RC08-0YE0<br />

CP 5623 communication<br />

processor<br />

<strong>PC</strong>I Express x1 card (32 bit) for<br />

connection to PROFIBUS incl.<br />

DP-Base software with NCM <strong>PC</strong>;<br />

DP-RAM interface for DP master<br />

or DP slave, incl. PG and FDL<br />

protocols; single license for<br />

1 installation, runtime software,<br />

software and electronic manual<br />

on CD-ROM, Class A, for<br />

operating system support see<br />

SIMATIC NET software;<br />

E 6GK1562-3AA00<br />

For upgrading from basic/RTX<br />

German/English<br />

V3.x, V4.0, V4.1 2005, 2008 and<br />

2009; single license, executable<br />

under Windows XP SP2 and SP3<br />

and Windows 7 (32 bits)<br />

CP 5611 A2 communication<br />

processor<br />

6GK1 561-1AA01<br />

CP 1616 communication<br />

processor<br />

<strong>PC</strong>I Card (32 bit; 3.3/5 V universal<br />

key) with ASIC ERTEC 400 for<br />

connecting <strong>PC</strong>s to PROFINET IO<br />

with 4-port real-time switch<br />

6GK1 161-6AA01<br />

<strong>PC</strong>I card (32 bit) for connection of<br />

a PG or <strong>PC</strong> to PROFIBUS<br />

(RJ45); incl. IO-Base software for<br />

PROFINET IO controller (RT<br />

operation) and NCM <strong>PC</strong>; single<br />

CP 5621 communication<br />

license for one installation,<br />

processor<br />

runtime software, software and<br />

<strong>PC</strong>I Express x1 card (32 bit) for E<br />

connection of a PG or <strong>PC</strong> to<br />

PROFIBUS<br />

6GK1 562-1AA00<br />

electronic manual on CD-ROM,<br />

Class A, for 32 bit Windows XP<br />

Professional; German/English<br />

<strong>PC</strong>I Express x1 card (32 bit)<br />

CP 5621 and MPI cable, 5 m<br />

CP 5603 Microbox Package<br />

E<br />

A<br />

6GK1 562-1AM00<br />

6GK1 560-3AU00<br />

CP 1604 Microbox Package<br />

Package for implementing the<br />

CP 1604 in the SIMATIC Microbox<br />

6GK1 160-4AU00<br />

Comprising CP 5603 module and<br />

Microbox expansion rack<br />

<strong>PC</strong>; comprising the CP 1604,<br />

connection board, power supply<br />

and expansion rack for Microbox<br />

CP 5613 A2 communication 6GK1 561-3AA01<br />

<strong>PC</strong>; for use with Development Kit<br />

processor<br />

<strong>PC</strong>I card (32 bit; 3.3 V/5 V) for<br />

connection to PROFIBUS incl.<br />

DP-Base software with NCM <strong>PC</strong>;<br />

DP-RAM interface for DP master,<br />

incl. PG and FDL protocol; single<br />

license for 1 installation, runtime<br />

software, software and electronic<br />

manual on CD-ROM, Class A, for<br />

32 bit Windows 2000 Professional/Server,<br />

Windows XP<br />

Professional, German/English<br />

DK-16xx PN IO; NCM <strong>PC</strong><br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/159<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

<strong>PC</strong>-based Controller<br />

SIMATIC WinAC RTX<br />

■ More information<br />

Add-ons for SIMATIC WinAC<br />

<strong>PC</strong>-based Competence Center Cologne<br />

Our add-ons supplement the WinAC RTX soft PLC by useful<br />

functions which have arisen in the context of projects. You can<br />

thus fully utilize the advantages of <strong>PC</strong>-based automation.<br />

The applications are available in the form of function blocks and<br />

are easy to use without special programming knowledge.<br />

Detailed information and prices can be obtained from your<br />

<strong>Siemens</strong> contact or from:<br />

Contact:<br />

<strong>Siemens</strong> AG<br />

Competence Center Cologne<br />

E-mail: CCCologne@siemens.com<br />

5/160<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Application Function<br />

WinAC serial driver Communication over serial interfaces<br />

WinAC <strong>PC</strong> IO driver Access to central I/O expansion<br />

<strong>PC</strong> IO including interrupt handling<br />

WinAC SQL Access to SQL databases<br />

WinAC TCP/IP driver Data exchange between WinAC<br />

and other communication<br />

partners over Windows interface<br />

using TCP/IP, UDP,<br />

or ISO-on-TCP<br />

WinAC O<strong>PC</strong> Client Access to various O<strong>PC</strong> servers<br />

WinAC Shutdown Controlled shutdown of WinAC<br />

and <strong>PC</strong> system<br />

WinAC File-I/O Reading and writing of DBs as file<br />

on the <strong>PC</strong> system<br />

WinAC Command Calling of batch commands from<br />

WinAC<br />

WinAC Access-DB High-performance access to<br />

DBs, bit memories or I/O image<br />

WinAC SMX Cover Provision of SMX functions,<br />

e. g. for Delphi or VB<br />

WinAC CMI Wrapper Simple program-based operation<br />

of WinAC<br />

Brochures<br />

Information material for downloading can be found on the<br />

Internet:<br />

www.siemens.com/simatic/printmaterial


■ Overview<br />

SIMATIC WinAC RTX F:<br />

Optimized for applications that demand a high degree of<br />

flexibility and integration capability and that must also satisfy<br />

safety requirements up to SIL 3 (IEC 61508).<br />

The software solution for tasks that require hard deterministic<br />

behavior and high performance.<br />

With real-time expansion for assuring deterministic behavior<br />

for the control section.<br />

Distributed I/O can be connected over PROFIBUS and/or<br />

PROFINET, also safety-related over PROFIsafe.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

<strong>PC</strong>-based Automation<br />

<strong>PC</strong>-based Controller<br />

SIMATIC WinAC RTX F<br />

Hard real-time and maximum performance up to SIL 3<br />

according to IEC 61508/62061 or according to<br />

EN ISO 13849-1 up to PL e<br />

Implementation of fast, S7-compatible control solutions with<br />

low processor loading.<br />

Alongside the control task, sufficient processor capability is<br />

available for processing complex, demanding <strong>PC</strong><br />

applications in parallel.<br />

■ Application<br />

WinAC RTX F is a fail-safe software controller approved by the<br />

German Technical Inspectorate for standard and safety-related<br />

applications. The <strong>ST</strong>EP 7 option package "S7 Distributed Safety"<br />

is used for programming the safety-related (F) program part.<br />

SIMATIC WinAC RTX F is particularly suited for tasks requiring a<br />

high level of flexibility and effective integration in the overall<br />

solution. This also includes close interlinking with data<br />

processing systems or logistics systems and integration in the<br />

safety control.<br />

WinAC RTX F is equally suited to implementation on costeffective<br />

<strong>PC</strong> platforms with single-core processors and on highend<br />

<strong>PC</strong>s, e. g. with QuadCore processors. WinAC RTX F is<br />

optimized for operation on embedded <strong>PC</strong> platforms such as the<br />

S7-modular Embedded Controller, the SIMATIC I<strong>PC</strong>427C, or the<br />

SIMATIC HMI I<strong>PC</strong>477C, I<strong>PC</strong>227D and HMI I<strong>PC</strong>277D. These<br />

platforms offer, with their diskless and fanless design, significantly<br />

enhanced ruggedness for an automation task. Nonvolatile<br />

memory is also available which permits storage of up to<br />

512 KB retentive data (S7-mEX, EC31) on a voltage dip,<br />

independently of the file system. The I/O is connected via the<br />

leading fieldbus standards of PROFINET or PROFIBUS. With the<br />

S7-mEC, EC31, operation is also possible with the central signal<br />

modules (SM) of S7-300.<br />

The support of the integrated PROFINET or PROFIBUS interfaces<br />

of the SIMATIC I<strong>PC</strong>s, as well as the excellent performance<br />

result in an excellent price/performance ratio for the <strong>PC</strong>-based<br />

automation.<br />

The WinAC ODK is used for expansion of the PLC functionality<br />

with application specific C/C++ applications. In the standard<br />

program part, it supports:<br />

integration of complex high-level language algorithms in the<br />

control program<br />

access to the Windows API or Windows system resources<br />

access to external hardware and software components<br />

Read-only access is permitted in the safety program part.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/161<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

<strong>PC</strong>-based Controller<br />

SIMATIC WinAC RTX F<br />

■ Design<br />

SIMATIC WinAC RTX F comprises the following components:<br />

Windows Failsafe Logic Controller (WinLC RTX F V4.6)<br />

WinAC TimeSynchronization<br />

SIMATIC NET SOFTNET-S7 Lean<br />

Real-time driver for PROFINET and PROFIBUS interfaces<br />

IntervalZero RTX real-time core for ensuring real-time and a<br />

deterministic response<br />

Optional:<br />

Interfaces for connection to PROFIBUS DP:<br />

- CP 5611 A2 or the integrated PROFIBUS interface of the<br />

SIMATIC I<strong>PC</strong><br />

- CP 5621<br />

- CP 5613 A2<br />

- CP 5603<br />

- CP 5623<br />

Interfaces for connection to PROFINET:<br />

- CP 1616 (HW version 8 and above) or integrated CP 161<br />

onboard interface of the SIMATIC I<strong>PC</strong><br />

- CP 1604 (HW version 7 and above)<br />

- IntegratedCP 1616 onboard interfaces of the SIMATIC I<strong>PC</strong><br />

- Integrated standard Ethernet interfaces of selected<br />

SIMATIC I<strong>PC</strong>s (e. g. SIMATIC I<strong>PC</strong>427C and HMI I<strong>PC</strong>477C)<br />

WinAC Open Development Kit (ODK):<br />

- For integrating C/C++ code in WinAC RTX<br />

- Integration of external software (technology programs) or<br />

<strong>PC</strong> components (e. g. barcode scanner, <strong>PC</strong> cards for<br />

measured value acquisition)<br />

■ Function<br />

Windows Failsafe Logic Controller (WinLC RTX F)<br />

The Windows Failsafe Logic Controller is responsible for the<br />

actual control job and execution of the control program.<br />

It coordinates the associated input and output of process values<br />

via the lower-level PROFINET or PROFIBUS fieldbus system and<br />

makes process values available for visualization and data<br />

processing tasks.<br />

Fail-safe programs are created with the <strong>ST</strong>EP 7 option package<br />

S7 Distributed Safety.<br />

A safety control can be built up using fail-safe signal modules.<br />

This opens up<br />

classical safety applications in the field of machine safety and<br />

press automation as well as<br />

applications in process engineering and chemicals.<br />

The I/O can be connected over PROFINET IO or PROFIBUS DP.<br />

The PROFIsafe profile supports fail-safe communication over the<br />

fieldbuses for this purpose.<br />

5/162<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

The functional safety is implemented by means of targeted<br />

safety functions in the software. Safety functions are implemented<br />

with S7 Distributed Safety, to place the plant in a safe<br />

state or to hold it in a safe state. The safety functions are mainly<br />

contained within the following components:<br />

in the safety-related user program (safety program) in<br />

WinLC RTX F<br />

in the fail-safe inputs and outputs (F I/O).<br />

The F I/O ensures safety-related processing of the field information<br />

(emergency stop pushbutton, light barriers, motor precontrol).<br />

It features all the hardware and software components<br />

required for reliable processing, according to the required safety<br />

class.<br />

The user only programs the user safety functions. The safety<br />

functions for the process can be implemented with a user safety<br />

function or a system-internal fault reaction function. If the<br />

F system is unable to execute the actual user safety function, it<br />

will execute the fault response function: e. g. deactivation of the<br />

associated outputs and, if appropriate, F-CPU in <strong>ST</strong>OP.<br />

Interface to visualization<br />

SIMATIC WinAC RTX F is easy to use with the SIMATIC HMI<br />

systems SIMATIC WinCC flexible or SIMATIC WinCC.<br />

Visualization systems from third-party suppliers can be<br />

connected via the included SIMATIC NET O<strong>PC</strong> server.<br />

Communication<br />

The programming of the Windows Logic Controller with <strong>ST</strong>EP 7<br />

as well as the visualization with SIMATIC HMI can be implemented<br />

both locally in the same <strong>PC</strong> and remotely using the<br />

standard SIMATIC networks Ethernet or PROFIBUS.<br />

WinAC RTX F can exchange data via these networks:<br />

with additional WinAC stations<br />

with S7 controllers as well as<br />

with safety-oriented S7 controllers (safe PLC-to-PLC<br />

communication)<br />

A SOFTNET S7 Lean license is included for Industrial Ethernet<br />

communication over the integrated Ethernet interfaces of the<br />

SIMATIC <strong>PC</strong>.


■ Technical specifications<br />

6ES7 671-1RC08-0YA0<br />

Product type designation SIMATIC WinAC RTX F 2010<br />

Product version<br />

Hardware product version -<br />

Firmware version V4.6<br />

Associated programming <strong>ST</strong>EP7 as of V5.5 + HW update /<br />

package<br />

iMap V3.0 SP1 / option package S7<br />

Distributed Safety V5.4 + SP5 / S7 F<br />

Configuration Pack V5.5 + SP6 +<br />

HF1<br />

Memory<br />

Work memory<br />

integrated (for program) 4 Mbyte; Adjustable; depends on<br />

Non Paged Memory Pool<br />

integrated (for data) 4 Mbyte; Adjustable; depends on<br />

Non Paged Memory Pool<br />

Load memory<br />

integrated RAM, max. Adjustable; depends on No<br />

Paged Memory Pool<br />

CPU-blocks<br />

DB<br />

Number, max. 65 535; Limited only by RAM<br />

set for data<br />

Size, max. 64 Kibyte<br />

FB<br />

Number, max. 65 536; Limited only by RAM<br />

set for code<br />

Size, max. 64 Kibyte<br />

FC<br />

Number, max. 65 536; Limited only by RAM<br />

set for code<br />

Size, max. 64 Kibyte<br />

OB<br />

Size, max. 64 Kibyte<br />

Nesting depth<br />

per priority class 24<br />

additional within an error OB 24<br />

CPU processing times<br />

for bit operations, min. 0.004 µs; typ.<br />

for fixed point arithmetic, min. 0.003 µs; typ.<br />

for floating point arithmetic, min. 0.004 µs; typ.<br />

Reference platform Pentium IV, 2.4 GHz<br />

Counters, timers and their<br />

retentivity<br />

S7 counter<br />

Number 2048<br />

Retentivity<br />

- can be set Yes<br />

-lower limit 0<br />

- upper limit 2047<br />

-preset 8<br />

Counting range<br />

- can be set Yes<br />

-lower limit 0<br />

- upper limit 999<br />

IEC counter<br />

present Yes<br />

Type SFB<br />

Number Unlimited<br />

(limited only by RAM capacity)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

<strong>PC</strong>-based Controller<br />

SIMATIC WinAC RTX F<br />

Product type designation<br />

S7 times<br />

6ES7 671-1RC08-0YA0<br />

SIMATIC WinAC RTX F 2010<br />

Number<br />

Retentivity<br />

2048<br />

-can be set Yes<br />

-lower limit 0<br />

- upper limit 2047<br />

-preset<br />

Time range<br />

0<br />

-lower limit 10 ms<br />

- upper limit<br />

IEC timer<br />

9990s<br />

present Yes<br />

Type SFB<br />

Number Unlimited (limited only by RAM<br />

capacity)<br />

Data areas and their retentivity<br />

Retentivity without UPS and PS<br />

Extension Board<br />

128 KB with SIMATIC I<strong>PC</strong>427C and<br />

HMI I<strong>PC</strong>477C; further SIMATIC <strong>PC</strong>s<br />

on request<br />

Retentivity with UPS<br />

Flag<br />

all data<br />

Number, max. 16 Kibyte<br />

Retentivity preset MB 0 to MB 15<br />

Number of clock memories<br />

Data blocks<br />

8<br />

Retentivity adjustable Yes; via non-retain property on DB<br />

Retentivity preset<br />

Local data<br />

Yes<br />

adjustable, max. 64 Kibyte<br />

preset 32 Kibyte<br />

per priority class, max.<br />

Address area<br />

I/O address area<br />

61 440 byte<br />

Inputs 16 Kibyte<br />

Outputs<br />

of which, distributed<br />

16 Kibyte<br />

- DP interface, inputs 16 Kibyte<br />

- DP interface, outputs 16 Kibyte<br />

- PN interface, inputs 16 Kibyte<br />

- PN interface, outputs<br />

Process image<br />

16 Kibyte<br />

Inputs, adjustable 8Kibyte<br />

Outputs, adjustable 8Kibyte<br />

Inputs, default 512 byte<br />

Outputs, default<br />

Subprocess images<br />

512 byte<br />

Number of subprocess images,<br />

max.<br />

Digital channels<br />

15<br />

Inputs 128 000<br />

Outputs<br />

Analog channels<br />

128 000<br />

Inputs <strong>80</strong>00<br />

Outputs <strong>80</strong>00<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/163<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

<strong>PC</strong>-based Controller<br />

SIMATIC WinAC RTX F<br />

■ Technical specifications (continued)<br />

6ES7 671-1RC08-0YA0<br />

Product type designation SIMATIC WinAC RTX F 2010<br />

Hardware configuration<br />

Submodules<br />

Number of submodules, max 4<br />

of which PROFIBUS, max. 4; Supported interfaces: see 1st<br />

and 2nd interface<br />

of which Industrial Ethernet,<br />

max.<br />

5/164<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

1; Supported interfaces: see 3rd<br />

and 4th interface<br />

Number of operable FMs and<br />

CPs (recommended)<br />

FM 4; FM distributed: FM 350-1, FM<br />

350-2, FM 351, FM 352 / FM 352-5,<br />

FM 353, FM 354, FM 355, FM 355-2<br />

CP, point-to-point 2; CP 340, CP 341 distributed<br />

CP, LAN<br />

Time of day<br />

Clock<br />

Over <strong>PC</strong> CP<br />

Hardware clock (real-time clock) Yes<br />

battery-backed and synchronizable<br />

Runtime meter<br />

Yes<br />

Number<br />

Clock synchronization<br />

8<br />

supported Yes<br />

to <strong>PC</strong>-CP, slave Yes<br />

on Ethernet via NTP<br />

1st interface<br />

Yes<br />

Type of interface CP 5611-A2, CP 5621, integrated<br />

PB interface of the SIMATIC <strong>PC</strong><br />

Max. no. of simultaneously<br />

operable CPs<br />

1<br />

Physics RS 485 / PROFIBUS<br />

Isolated Yes<br />

Number of connection resources<br />

Functionality<br />

8<br />

MPI No<br />

DP master Yes<br />

DP slave<br />

DP master<br />

No<br />

Number of connections, max.<br />

Services<br />

8<br />

- PG/OP communication Yes<br />

- Global data communication No<br />

- S7 basic communication No<br />

- S7 communication Yes<br />

- S7 communication, as client Yes<br />

- S7 communication, as server Yes<br />

- Equidistance mode support Yes; Only in conjunction with<br />

isochronous mode<br />

- Isochronous mode Yes<br />

- SYNC/FREEZE Yes<br />

- Activation/deactivation of DP<br />

slaves<br />

Yes<br />

- Direct data exchange (slaveto-slave<br />

communication)<br />

Yes<br />

- DPV1 Yes<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Product type designation<br />

DP master<br />

6ES7 671-1RC08-0YA0<br />

SIMATIC WinAC RTX F 2010<br />

Transmission rate, max. 12 Mbit/s<br />

Number of DP slaves, max.<br />

Address area<br />

64<br />

- Inputs, max. 16 Kibyte<br />

-Outputs, max.<br />

User data per DP slave<br />

16 Kibyte<br />

- Inputs, max. 244 byte<br />

-Outputs, max.<br />

2nd interface<br />

244 byte<br />

Type of interface CP 5613, CP 5613-A2, CP 5603,<br />

CP 5623<br />

Max. no. of simultaneously<br />

operable CPs<br />

4<br />

Physics RS 485 / PROFIBUS<br />

Isolated<br />

Functionality<br />

Yes<br />

MPI No<br />

DP master Yes<br />

DP slave<br />

DP master<br />

No<br />

Number of connections, max.<br />

Services<br />

50<br />

- PG/OP communication Yes<br />

- Global data communication No<br />

- S7 basic communication No<br />

- S7 communication Yes<br />

- S7 communication, as client Yes<br />

- S7 communication, as server Yes<br />

- Equidistance mode support Yes; Only in conjunction with<br />

isochronous mode<br />

- Isochronous mode Yes<br />

- SYNC/FREEZE Yes<br />

- Activation/deactivation of DP<br />

slaves<br />

Yes<br />

- Direct data exchange (slaveto-slave<br />

communication)<br />

Yes<br />

- DPV1 Yes<br />

Transmission rate, max. 12 Mbit/s<br />

Number of DP slaves, max.<br />

Address area<br />

125<br />

- Inputs, max. 16 Kibyte<br />

-Outputs, max.<br />

User data per DP slave<br />

16 Kibyte<br />

- Inputs, max. 244 byte<br />

-Outputs, max. 244 byte


■ Technical specifications (continued)<br />

6ES7 671-1RC08-0YA0<br />

Product type designation SIMATIC WinAC RTX F 2010<br />

3rd interface<br />

Type of interface PROFINET<br />

Max. no. of simultaneously<br />

operable CPs<br />

1; Intel Pro/1000 (Intel 82571EB,<br />

82573L, 82574L, 82541PI; nonshared<br />

IRQ required); integrated IE<br />

interface SIMATIC <strong>PC</strong> 4x7B, 6x7B,<br />

8x7B, I<strong>PC</strong>4x7C, I<strong>PC</strong>6x7C, I<strong>PC</strong>8x7C<br />

Physics Ethernet<br />

Isolated Yes<br />

Integrated switch No<br />

Number of ports 1<br />

automatic detection of transmission<br />

speed<br />

Yes; 10/100 Mbit/s<br />

Autonegotiation Yes<br />

Autocrossing<br />

Media redundancy<br />

Yes<br />

supported<br />

Functionality<br />

No<br />

PROFINET IO Controller Yes<br />

PROFINET IO Device No<br />

PROFINET CBA<br />

PROFINET IO Controller<br />

Services<br />

Yes<br />

- PG/OP communication Yes<br />

- S7 communication Yes<br />

- Isochronous mode No<br />

- Open IE communication Yes<br />

Transmission rate, min. 100 Mbit/s<br />

Transmission rate, max. 100 Mbit/s<br />

Number of connectable IO<br />

Devices, max.<br />

128<br />

Max. number of connectable IO<br />

devices for RT<br />

128<br />

- of which in line, max. 128<br />

IRT, supported No<br />

Prioritized startup supported Yes<br />

- Number of IO Devices, max. 32<br />

Activation/deactivation of IO<br />

Devices<br />

Yes<br />

- Number of IO Devices that can<br />

be simultaneously activated/<br />

deactivated, max.<br />

8<br />

IO Devices changing during<br />

operation (partner ports),<br />

supported<br />

Yes<br />

Device replacement without<br />

swap medium<br />

Yes<br />

Send clock times 1 ms<br />

Updating time 1 - 512 ms (minimum value<br />

depends on communication share<br />

set for PROFINET I/O, on the<br />

number of I/O devices, and on the<br />

volume of configured user data)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

<strong>PC</strong>-based Controller<br />

SIMATIC WinAC RTX F<br />

6ES7 671-1RC08-0YA0<br />

Product type designation SIMATIC WinAC RTX F 2010<br />

PROFINET IO Controller<br />

Address area<br />

- Inputs, max. 16 Kibyte<br />

-Outputs, max. 16 Kibyte<br />

User data per address area, 2Kibyte<br />

max.<br />

- User data consistency, max. 256 byte<br />

Open IE communication<br />

Open IE communication, Yes<br />

supported<br />

Number of connections, max. 32<br />

Local port numbers used at the<br />

system end<br />

Keep-alive function, supported<br />

4th interface<br />

Yes<br />

Type of interface PROFINET<br />

Max. no. of simultaneously<br />

operable CPs<br />

0, 20, 21, 23, 25, <strong>80</strong>, 102, 135, 161,<br />

<strong>80</strong><strong>80</strong>, 34962, 34963, 34964, 65532,<br />

65533, 65534, 65535<br />

1; CP 1616 (HW release 8 or<br />

above), CP 1604 (HW release 7 or<br />

higher), integrated PN interface of<br />

SIMATIC <strong>PC</strong> and S7-mEC<br />

Physics Ethernet<br />

Isolated Yes<br />

Integrated switch Yes<br />

Number of ports 3<br />

automatic detection of transmission<br />

speed<br />

Yes; 10/100 Mbit/s<br />

Autonegotiation Yes<br />

Autocrossing<br />

Media redundancy<br />

Yes<br />

supported Yes<br />

Switchover time on line break,<br />

typically<br />

200 ms<br />

Number of stations in the ring,<br />

max.<br />

50<br />

Change of IP address at runtime,<br />

supported<br />

Yes<br />

Number of connection resources<br />

Functionality<br />

32<br />

PROFINET IO Controller Yes<br />

PROFINET IO device No<br />

PROFINET CBA Yes<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/165<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

<strong>PC</strong>-based Controller<br />

SIMATIC WinAC RTX F<br />

■ Technical specifications (continued)<br />

6ES7 671-1RC08-0YA0<br />

Product type designation SIMATIC WinAC RTX F 2010<br />

PROFINET IO Controller<br />

Services<br />

- PG/OP communication Yes<br />

- S7 communication Yes<br />

- Isochronous mode Yes<br />

- Open IE communication Yes<br />

Transmission rate, max. 100 Mbit/s<br />

Number of connectable IO<br />

devices, max.<br />

256<br />

Max. number of connectable IO<br />

Devices for RT<br />

256<br />

- of which in line, max. 256<br />

Number of IO Devices with IRT<br />

and the option "high flexibility"<br />

64<br />

- of which in line, max. 32<br />

Number of IO Devices with IRT<br />

and the option "high performance",<br />

max.<br />

64<br />

- of which in line, max. 64<br />

IRT, supported Yes<br />

Shared device, supported Yes<br />

Prioritized startup supported Yes<br />

- Number of IO Devices, max. 32<br />

Activation/deactivation of IO<br />

Devices<br />

Yes<br />

- Number of IO Devices that<br />

can be simultaneously<br />

activated/deactivated, max.<br />

8<br />

IO Devices changing during<br />

operation (partner ports),<br />

supported<br />

Yes<br />

Device replacement without<br />

swap medium<br />

Yes<br />

Send clock times 250 µs, 500 µs, 1 ms<br />

Updating time<br />

Address area<br />

0.25...512 depending on the send<br />

cycle<br />

- Inputs, max. 16 Kibyte<br />

- Outputs, max. 16 Kibyte<br />

User data per address area,<br />

max.<br />

2Kibyte<br />

- User data consistency, max. 256 byte<br />

5/166<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6ES7 671-1RC08-0YA0<br />

Product type designation SIMATIC WinAC RTX F 2010<br />

Open IE communication<br />

Open IE communication, Yes<br />

supported<br />

Number of connections, max. 32<br />

Local port numbers used at<br />

the system end<br />

0, 20, 21, 25, <strong>80</strong>, 102, 135, 161,<br />

34962, 34963, 34964, 65532,<br />

65533, 65534, 65535<br />

Communication functions<br />

PG/OP communication Yes<br />

Data record routing<br />

Global data communication<br />

Yes; Only with CP 5611 or<br />

integrated PROFIBUS interface of<br />

the SIMATIC <strong>PC</strong><br />

supported<br />

S7 basic communication<br />

No<br />

supported<br />

S7 communication<br />

No<br />

supported Yes<br />

as server Yes<br />

as client Yes<br />

User data per job, max.<br />

Open IE communication<br />

64 Kibyte; Depends on which block<br />

is used: BSEND/USEND or PUT/<br />

GET<br />

TCP/IP Yes<br />

- Number of connections, max. 32<br />

- Data length, max. 65 534 byte<br />

ISO-on-TCP (RFC1006) Yes<br />

- Number of connections, max. 32<br />

- Data length, max. 65 534 byte<br />

UDP Yes<br />

- Number of connections, max. 32<br />

- Data length, max.<br />

Web server<br />

1472byte<br />

supported Yes<br />

Number of HTTP clients 2<br />

User-defined websites No


■ Technical specifications (continued)<br />

6ES7 671-1RC08-0YA0<br />

Product type designation SIMATIC WinAC RTX F 2010<br />

PROFINET CBA (at set setpoint<br />

communication load)<br />

Setpoint for the CPU communication<br />

load<br />

Number of remote interconnection<br />

partners<br />

Number of functions, master/<br />

slave<br />

Total of all Master/Slave<br />

connections<br />

Data length of all incoming<br />

connections master/slave, max.<br />

Data length of all outgoing<br />

connections master/slave, max.<br />

Number of device-internal and<br />

PROFIBUS interconnections<br />

Data length of device-internal<br />

und PROFIBUS interconnections,<br />

max.<br />

Data length per connection,<br />

max.<br />

Remote interconnections with<br />

acyclic transmission<br />

- Sampling frequency:<br />

Sampling time, min.<br />

- Number of incoming interconnections<br />

- Number of outgoing interconnections<br />

- Data length of all incoming<br />

interconnections, max.<br />

- Data length of all outgoing<br />

interconnections, max.<br />

- Data length per connection,<br />

max.<br />

Remote interconnections with<br />

cyclic transmission<br />

- Transmission frequency:<br />

Transmission interval, min.<br />

- Number of incoming interconnections<br />

- Number of outgoing interconnections<br />

- Data length of all incoming<br />

interconnections, max.<br />

- Data length of all outgoing<br />

interconnections, max.<br />

- Data length per connection,<br />

max.<br />

20%<br />

64<br />

30<br />

1000<br />

6<strong>80</strong>0byte<br />

6<strong>80</strong>0byte<br />

500<br />

4000byte<br />

1400byte<br />

500 ms<br />

100<br />

100<br />

2000byte<br />

2000byte<br />

1400byte<br />

10 ms<br />

200<br />

200<br />

4<strong>80</strong>0byte<br />

4<strong>80</strong>0byte<br />

250 byte<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

<strong>PC</strong>-based Controller<br />

SIMATIC WinAC RTX F<br />

6ES7 671-1RC08-0YA0<br />

Product type designation SIMATIC WinAC RTX F 2010<br />

PROFINET CBA (at set setpoint<br />

communication load)<br />

HMI variables via PROFINET<br />

(acyclic)<br />

- Number of stations that can 3<br />

log on for HMI variables<br />

(PN O<strong>PC</strong>/iMap)<br />

- HMI variable updating 500 ms<br />

- Number of HMI variables 200<br />

- Data length of all HMI 2000byte<br />

variables, max.<br />

PROFIBUS proxy functionality<br />

- supported Yes<br />

- Number of linked PROFIBUS 16<br />

devices<br />

- Data length per connection, 240 byte; Slave-dependent<br />

max.<br />

Number of connections<br />

overall 96<br />

S7 message functions<br />

Number of login stations for 62<br />

message functions, max.<br />

SCAN procedure No<br />

Process diagnostic messages Yes; ALARM_S, ALARM_SQ,<br />

ALARM_D, ALARM_DQ<br />

simultaneously active Alarm-S 20; of a total of 20 for all SFCs<br />

blocks, max.<br />

Alarm 8-blocks Yes<br />

Number of instances for alarm 8 4000<br />

and S7 communication blocks,<br />

max.<br />

Process control messages No<br />

Test commissioning functions<br />

Status/control<br />

Status/control variable<br />

Forcing<br />

Yes<br />

Forcing No<br />

Status block Yes<br />

Single step Yes<br />

Number of breakpoints<br />

Diagnostic buffer<br />

20<br />

present Yes<br />

Number of entries, max. 3200<br />

-can be set Yes<br />

-preset 120<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/167<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

<strong>PC</strong>-based Controller<br />

SIMATIC WinAC RTX F<br />

■ Technical specifications (continued)<br />

6ES7 671-1RC08-0YA0<br />

Product type designation SIMATIC WinAC RTX F 2010<br />

Isochronous mode<br />

Isochronous mode Yes<br />

Number of DP masters with 2<br />

isochronous mode<br />

User data per isochronous slave, 128 byte<br />

max.<br />

Equidistance Yes<br />

Shortest clock pulse 2.2 ms; 2.2 ms without partial<br />

process image; 2.2 ms with partial<br />

process image<br />

Hardware requirements<br />

Hardware required <strong>PC</strong> with color monitor, keyboard,<br />

mouse or pointing device for<br />

Windows<br />

Required memory on hard disk, 100 Mbyte<br />

min.<br />

Main memory, min. 1Gbyte<br />

Processor Intel Celeron M 900 MHz or<br />

compatible (older <strong>PC</strong> systems with<br />

Programmable Interrupt Controllers<br />

(PIC) are not suitable for WinAC<br />

RTX F 2010.)<br />

Multi-processor system No<br />

Hyper-threading Yes<br />

Operating systems<br />

Windows NT 4.0 No<br />

Windows 2000 No<br />

Windows XP Yes; Professional, SP2 and SP3<br />

Windows XP embedded Yes; With the delivery image of the<br />

SIMATIC <strong>PC</strong><br />

Supported HAL types under<br />

Windows XP<br />

5/168<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

ACPI uniprocessor <strong>PC</strong>, ACPI multiprocessor<br />

<strong>PC</strong>, MPS multiprocessor<br />

<strong>PC</strong><br />

Windows Vista No<br />

Windows embedded Standard 7 No<br />

Windows 7 Yes; Professional, Enterprise,<br />

Ultimate (only 32 bits)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6ES7 671-1RC08-0YA0<br />

Product type designation SIMATIC WinAC RTX F 2010<br />

Configuration<br />

programming<br />

Programming language<br />

-LAD Yes<br />

-FBD Yes<br />

-<strong>ST</strong>L Yes<br />

-SCL Yes<br />

-CFC Yes<br />

- GRAPH Yes<br />

-HiGraph® Yes<br />

Nesting levels 8<br />

Software libraries<br />

- Easy Motion Control Yes<br />

Know-how protection<br />

User program protection/ Yes<br />

password protection<br />

Block encryption No<br />

Open Development interfaces<br />

CCX (Custom Code Extension) Yes; WinAC ODK V4.2 or higher<br />

CMI (Controller Management Yes; WinAC ODK V4.2 or higher<br />

Interface)<br />

SMX (Shared Memory<br />

Yes; WinAC ODK V4.2 or higher<br />

Extension)<br />

- Inputs 4Kibyte<br />

-Outputs 4Kibyte<br />

Dimensions and weight<br />

Weight<br />

Weight, approx. 100 g; with packaging


A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

<strong>PC</strong>-based Controller<br />

SIMATIC WinAC RTX F<br />

■ Ordering data Order No. Order No.<br />

SIMATIC WinAC RTX F 2010 B 6ES7 671-1RC08-0YA0<br />

CP 5623 communication E 6GK1 562-3AA00<br />

SIMATIC WinAC RTX F 2010 B 6ES7 671-1RC08-0YE0<br />

processor<br />

upgrade<br />

<strong>PC</strong>I Express x1 card (32 bit) for<br />

CP 5611 A2 communication<br />

processor<br />

6GK1 561-1AA01<br />

connection to PROFIBUS incl.<br />

DP-Base software with NCM <strong>PC</strong>;<br />

DP-RAM interface for DP master<br />

<strong>PC</strong>I card (32 bit) for connection of<br />

or DP slave, incl. PG and FDL<br />

a PG or <strong>PC</strong> to PROFIBUS<br />

protocols; single license for<br />

CP 5621 communication<br />

processor<br />

1 installation, runtime software,<br />

software and electronic manual<br />

on CD-ROM, Class A, for<br />

<strong>PC</strong>I Express x1 card (32 bit) for<br />

connection of a PG or <strong>PC</strong> to<br />

PROFIBUS<br />

E 6GK1 562-1AA00<br />

operating system support see<br />

SIMATIC NET software;<br />

German/English<br />

<strong>PC</strong>I Express x1 card (32 bit)<br />

CP 5621 and MPI cable, 5 m<br />

E 6GK1 562-1AM00<br />

CP 1616 communication<br />

processor<br />

6GK1 161-6AA01<br />

CP 5603 Microbox Package A<br />

Comprising CP 5603 module and<br />

Microbox expansion rack<br />

6GK1 560-3AU00<br />

<strong>PC</strong>I Card (32 bit; 3.3/5 V universal<br />

key) with ASIC ERTEC 400 for<br />

connecting <strong>PC</strong>s to PROFINET IO<br />

with 4-port real-time switch<br />

CP 5613 A2 communication<br />

processor<br />

6GK1 561-3AA01<br />

(RJ45); incl. IO-Base software for<br />

PROFINET IO controller<br />

(RT operation) and NCM <strong>PC</strong>;<br />

<strong>PC</strong>I card (32 bit; 3.3 V/5 V) for<br />

single license for one installation,<br />

connection to PROFIBUS incl.<br />

runtime software, software and<br />

DP-Base software with NCM <strong>PC</strong>;<br />

electronic manual on CD-ROM,<br />

DP-RAM interface for DP master,<br />

Class A, for 32 bit Windows XP<br />

incl. PG and FDL protocol; single<br />

Professional;<br />

license for 1 installation, runtime<br />

German/English<br />

software, software and electronic<br />

manual on CD-ROM, Class A, for<br />

CP 1604 Microbox Package 6GK1 160-4AU00<br />

32 bit Windows 2000 Professional/Server,<br />

Windows XP<br />

Professional, German/English<br />

Package for implementing the<br />

CP 1604 in the SIMATIC Microbox<br />

<strong>PC</strong>; comprising the CP 1604,<br />

connection board, power supply<br />

and expansion rack for Microbox<br />

<strong>PC</strong>; for use with Development Kit<br />

DK-16xx PN IO; NCM <strong>PC</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/169<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

<strong>PC</strong>-based Controller<br />

SIMATIC WinAC RTX F<br />

■ More information<br />

Add-ons for SIMATIC WinAC<br />

<strong>PC</strong>-based Competence Center Cologne<br />

Our add-ons supplement the WinAC RTX soft PLC by useful<br />

functions which have arisen in the context of projects. In this<br />

way, you can fully utilize the advantages of <strong>PC</strong> based<br />

automation.<br />

The applications are available in the form of function blocks and<br />

are easy to use without special programming knowledge.<br />

Detailed information and prices can be obtained from your<br />

<strong>Siemens</strong> contact or from:<br />

Contact:<br />

<strong>Siemens</strong> AG<br />

Competence Center Cologne<br />

E-mail: CCCologne@siemens.com<br />

5/170<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Application Function<br />

WinAC serial driver Communication over serial interfaces<br />

WinAC <strong>PC</strong> IO driver Access to central I/O expansion<br />

<strong>PC</strong> IO including interrupt handling<br />

WinAC SQL Access to SQL databases<br />

WinAC TCP/IP driver Data exchange between WinAC and<br />

other communication partners over<br />

Windows interface using TCP/IP,<br />

UDP, or ISO-on-TCP<br />

WinAC O<strong>PC</strong> Client Access to various O<strong>PC</strong> servers<br />

WinAC Shutdown Controlled shutdown of WinAC and<br />

the <strong>PC</strong> system<br />

WinAC File I/O Reading and writing of DBs as a file<br />

on the <strong>PC</strong> system<br />

WinAC Command Calling batch commands from<br />

WinAC<br />

WinAC Access DB High-performance accesses to DBs,<br />

bit memories or I/O image<br />

WinAC SMX Cover Provides SMX functions, e. g. for<br />

Delphi or VB<br />

WinAC CMI Wrapper Easy program-controlled operation of<br />

WinAC<br />

Brochures<br />

Information material is available for downloading on the Internet<br />

at: www.siemens.com/simatic/printmaterial


■ Overview<br />

SIMATIC WinAC software PLCs support powerful interfaces<br />

which permit close meshing of the control task with <strong>PC</strong>-based<br />

applications.<br />

WinAC ODK allows the user to develop applications or to<br />

integrate already existing applications into the control task.<br />

New with WinAC ODK V4.2:<br />

CCX interface:<br />

- New SFB 65003 for asynchronous execution of ODK<br />

applications<br />

- Expansion of data access functions<br />

- Creation of Windows DLL with C# and VB<br />

SMX interface:<br />

- Access to the Shared Memory interface under<br />

IntervalZero RTX<br />

- Expansion of data access functions<br />

- Creation of Windows applications with C# and VB<br />

Supports MS Visual Studio 2005 and 2008 (under Windows)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Application<br />

<strong>PC</strong>-based Automation<br />

<strong>PC</strong>-based Controller<br />

SIMATIC WinAC ODK<br />

WinAC ODK can be used to meet the following requirements:<br />

Integration of specific technology into the control task,<br />

e. g. measured data acquisition or analysis, vision systems or<br />

<strong>PC</strong>-based motion solutions<br />

Access to typical <strong>PC</strong> resources such as file system, interfaces<br />

etc.<br />

Typical examples of uses for WinAC ODK include:<br />

Connection of specific fieldbus systems to the controller<br />

Direct, powerful connection of the control program to a<br />

production database<br />

Integration of robotics systems<br />

Implementation of specific communication protocols<br />

■ Function<br />

SIMATIC WinAC ODK<br />

Overview<br />

WinAC ODK V4.2 supports the development of customdesigned<br />

applications for WinAC RTX with a high-level language<br />

development tool such as Microsoft Visual Studio. WinAC RTX<br />

provides 3 different interfaces for this:<br />

The Custom Code Extension (CCX) interface allows the direct<br />

start-up of high-level language applications or functions which<br />

are available in the form of DLLs for Windows or real-time<br />

DLLs for IntervalZero RTX, the real-time kernel used by<br />

WinAC RTX. Implementation as a DLL gives the developer<br />

complete access to the operating system APIs, software<br />

interfaces of other programs, or even resources of the <strong>PC</strong><br />

(drivers, hardware). These DLLs are developed with the aid of<br />

the ODK.<br />

The Shared Memory Extension (SMX) interface allows the fast<br />

exchange of data between the PLC program of the<br />

WinAC RTX and a user application. The Shared Memory can<br />

be addressed from the PLC in the input/output area and can<br />

be used, for example, in the same manner as a DP-DP coupler<br />

with a 4 KB input/output area.<br />

The Controller Management Interface (CMI) provides all of the<br />

functions of the WinAC panel for the customer application.<br />

This allows the WinAC RTX to be operated completely via a<br />

customer application such as a visualization software.<br />

Creation of WinAC ODK applications<br />

WinAC ODK applications are created using Microsoft Visual<br />

Studio. Depending on the interface runtime environment, it is<br />

possible to use different programming languages:<br />

CCX and SMX applications under IntervalZero RTX:<br />

Visual C++<br />

CCX, SMX and CMI applications under Windows:<br />

Visual C++, C#, Visual Basic<br />

If a CCX or SMX application is supposed to work with<br />

WinAC RTX in real-time, an IntervalZero SDK<br />

(from IntervalZero Inc.) that matches the version of the real-time<br />

kernel used by WinAC RTX is required.<br />

For ease of understanding and a quick start in an ODK application,<br />

the creation of CCX and SMX applications is supported<br />

by a wizard. Some programming examples are also included in<br />

the delivery kit.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/171<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

<strong>PC</strong>-based Controller<br />

SIMATIC WinAC ODK<br />

■ Function (continued)<br />

Custom Code Extension Interface (CCX)<br />

Applications that use the CCX interface can run both in Windows<br />

and in the IntervalZero RTX context, which means that, in<br />

principle, there are no restrictions with regard to the language<br />

elements used when programming this application.<br />

CCX applications are executed as DLLs under Windows or realtime<br />

DLLs under Ardence RTX.<br />

The application programmer is supported by a wizard when<br />

creating the following application types and functions:<br />

Synchronous start of the ODK application:<br />

The code is executed as part of the PLC code.<br />

Asynchronous start:<br />

The code is started in parallel to the PLC and is executed in<br />

the background.<br />

Continuous process:<br />

The ODK application runs parallel to the PLC and alerts the<br />

PLC program by calling up an alarm OB.<br />

Special system function blocks are available at the PLC end for<br />

starting the CCX application and starting its functions.<br />

Shared Memory Extension Interface (SMX)<br />

WinAC RTX provides a Shared Memory area which can be<br />

accessed as required by both the PLC application program and<br />

the SMX application. This type of coupling allows for very<br />

efficient exchange of data and a far-reaching uncoupling of the<br />

PLC version from the SMX application which is also accessing<br />

data.<br />

From the viewpoint of WinAC RTX, the Shared Memory is located<br />

in the I/O address area with 4 KB each of input and output.<br />

Access is possible using load/transfer commands. Access<br />

functions are available at the SMX application end.<br />

Just as for the CCX interface, a wizard supports the creation of<br />

SMX applications.<br />

Some typical applications for the SMX interface are:<br />

data archiving<br />

fast data coupling to software for optimizing production<br />

simple, fast data interface to operating software with<br />

Visual Basic or C#<br />

5/172<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Controller Management Interface (CMI)<br />

The CMI allows the integration of the WinAC CPU panel functionality<br />

into a <strong>PC</strong> application. The following panel functions can be<br />

carried out by the <strong>PC</strong> application (examples):<br />

Starting and shutting down the controller.<br />

Operating the (RUN/<strong>ST</strong>OP) key-operated switch.<br />

Status LED display.<br />

Loading user programs.<br />

This allows for flexible integration of WinAC into the overall application:<br />

Starting and stopping the controller in relation to other<br />

applications, e. g. defining the start sequence when starting<br />

up the <strong>PC</strong>.<br />

Automatic reload of updated PLC user programs ("machine<br />

update" by OEM).<br />

Distribution of the WinAC ODK application<br />

WinAC ODK is only needed for the development of applications<br />

(development license). No additional licenses are required by<br />

WinAC for applications created using ODK (runtime licenses).<br />

At the WinAC Software PLC or Slot PLC, such an application is<br />

integrated with the usual SIMATIC PLC programming<br />

languages.<br />

The PLC programmer can also use these applications without<br />

having higher-level programming languages expertise. For<br />

the PLC programmer, the ODK application looks like a function<br />

of the PLC.<br />

To make it easier for the PLC programmer to use the<br />

application, a <strong>ST</strong>EP 7 library can be created, which provides<br />

simple FC/FB calls for handling the ODK application.


© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

<strong>PC</strong>-based Controller<br />

SIMATIC WinAC ODK<br />

■ Technical specifications ■ Ordering data Order No.<br />

6ES7 <strong>80</strong>6-1CC03-0BA0<br />

SIMATIC WinAC ODK V4.2<br />

Product type designation SIMATIC WinAC ODK V4.2 for integration of C/C++ code in<br />

Hardware requirements<br />

Hardware required<br />

Required memory on hard disk,<br />

<strong>PC</strong> with color monitor, keyboard,<br />

mouse or pointing device for<br />

Windows<br />

30 Mbyte<br />

WinAC PLCs, executable under<br />

Windows XP SP2 or SP3;<br />

CD-ROM with electronic<br />

documentation<br />

Single license B 6ES7 <strong>80</strong>6-1CC03-0BA0<br />

min.<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

Main memory, min. 512 Mbyte<br />

Processor Intel Pentium <strong>80</strong>0 MHz ■ More information<br />

Operating systems<br />

Windows XP Yes; Professional, SP2 and SP3 Brochures<br />

Configuration<br />

Information material for downloading can be found on the<br />

Open Development interfaces<br />

Internet:<br />

CCX (Custom Code Extension) Yes; WinAC RTX 2008 (V4.4) or<br />

higher; programming languages:<br />

Microsoft Visual C++ V6.0 SP5 or<br />

higher, .net 2003, 2005, 2008;<br />

Microsoft Visual Basic 2005,<br />

2008; Microsoft Visual C# 2005,<br />

2008<br />

www.siemens.com/simatic/printmaterial<br />

CMI (Controller Management Yes; WinAC RTX 2005 SP2 (V4.3)<br />

Interface)<br />

or higher; programming<br />

languages: Microsoft Visual<br />

C++ V6.0 SP5 or higher, .net<br />

2003, 2005, 2008; Microsoft<br />

Visual Basic V6.0 SP5 or higher,<br />

.net 2003, 2005, 2008; Microsoft<br />

Visual C# .net 2003, 2005, 2008<br />

SMX (Shared Memory Extension)<br />

Dimensions and weight<br />

Yes; WinAC RTX 2008 (V4.4) or<br />

higher; programming languages:<br />

Microsoft Visual C++ V6.0 SP5 or<br />

higher, .net 2003, 2005, 2008;<br />

Microsoft Visual Basic 2005,<br />

2008; Microsoft Visual C# 2005,<br />

2008<br />

Weight, approx. 200 g<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/173<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Embedded Controller<br />

Embedded Controller<br />

■ Overview<br />

An embedded <strong>PC</strong> or an embedded device is combined with<br />

automation software (e. g. Software PLC, HMI system) to form a<br />

turnkey system.<br />

Windows Embedded Standard or Windows Embedded<br />

Compact is used as the operating system.<br />

SIMATIC Embedded Automation comprises:<br />

Control<br />

Technology<br />

Visualization<br />

Data processing<br />

Communication<br />

Fail-safe<br />

on a common embedded <strong>PC</strong> platform.<br />

5/174<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

S7-mEC<br />

SIMATIC S7-mEC is a modular controller in S7-300 design with<br />

powerful embedded <strong>PC</strong> technology. The embedded controller<br />

combines the advantages of the tried and tested modular<br />

S7 controller with <strong>PC</strong> technology in one new device.<br />

SIMATIC S7-mEC RTX is characterized by:<br />

maximum ruggedness without fan or hard disk<br />

modular expansion options, e. g. central expansion with<br />

S7-300 I/O or <strong>PC</strong> interfaces<br />

commissioning, as for S7-300, by automation specialists<br />

SIMATIC WinAC RTX or alternatively WinAC RTX F preinstalled<br />

as a software PLC.<br />

SIMATIC I<strong>PC</strong>427C bundles<br />

The SIMATIC I<strong>PC</strong>427C-RTX bundles are ready-to-use,<br />

combined embedded <strong>PC</strong>s with the following SIMATIC software<br />

options:<br />

SIMATIC WinAC RTX<br />

SIMATIC WinAC RTX F<br />

SIMATIC WinCC flexible<br />

SIMATIC WinCC flexible with WinAC RTX<br />

The combination unites the openness of <strong>PC</strong>-based controllers<br />

with the ruggedness of a conventional PLC: Flexible software<br />

and high-performance, scalable hardware in an open, compact<br />

unit.<br />

An automation system is thus available to users with which strict<br />

real-time automation tasks and superior visualization tasks can<br />

be handled on a compact and rugged platform. This platform<br />

also offers versatility and efficient integration in the overall task.<br />

This includes close interlinking with data processing and logistic<br />

systems as well as interfacing with technology tasks such as<br />

motion control or vision systems.<br />

Windows XP Embedded is used as the operating system.<br />

SIMATIC HMI I<strong>PC</strong> 477C bundles<br />

As in the case of SIMATIC I<strong>PC</strong>427C, the SIMATIC HMI I<strong>PC</strong>477C<br />

can also be ordered with SIMATIC software installed and ready<br />

to use:<br />

SIMATIC WinCC flexible<br />

SIMATIC WinCC flexible with WinAC RTX<br />

SIMATIC WinAC RTX<br />

SIMATIC WinAC RTX F<br />

The panels are available in 12", 15" and 19" front versions, alternatively<br />

with touch or key functionality. With their compact<br />

structure, the Panel <strong>PC</strong>s are the ideal combination of controller<br />

and HMI functionality on a single platform and also offer the<br />

openness of a <strong>PC</strong>-based system.<br />

Multi Panels MP 177, MP 277 and MP 377 with WinAC MP<br />

Multi Panels (MP) are – like Operator Panels – used for<br />

machine operation and monitoring on-site.<br />

Additional Windows CE applications (Software PLC and<br />

Sm@rt options) can be installed to expand their functional<br />

scope.<br />

The SIMATIC Multi Panels combine the ruggedness of<br />

Operator Panels with the flexibility of <strong>PC</strong>s, on the basis of<br />

Windows CE.<br />

With the SIMATIC Multi Panels, the contents of the message<br />

buffer are retained with the panel switched off, without the<br />

need for a battery.


■ Overview (continued)<br />

Decision aid for the use of embedded systems<br />

Applies<br />

o Applies under certain conditions<br />

- Does not apply<br />

■ More information<br />

Brochures<br />

Information material for downloading can be found on the<br />

Internet:<br />

www.siemens.com/simatic/printmaterial<br />

<strong>PC</strong>-based Automation<br />

Embedded Controller<br />

Embedded Controller<br />

Customer benefits Modular Control Embedded Automation <strong>PC</strong>-based<br />

Automation<br />

Design<br />

SIMATIC S7 Multi Panel<br />

(MP)<br />

S7-modular<br />

Embedded Controller<br />

(mEC)<br />

I<strong>PC</strong>427C,<br />

HMI I<strong>PC</strong>477C<br />

bundles<br />

on SIMATIC <strong>PC</strong><br />

Ruggedness (depends on<br />

hardware configuration)<br />

Type of construction Modular Compact Modular Compact Depending on the<br />

type of construction<br />

Spare parts availability<br />

(beyond date of discontinuation)<br />

Performance<br />

10 years 10 years 5 years 5 years 5 years<br />

Fast restart after power<br />

failure<br />

Hard real-time<br />

- - - -<br />

Fast program<br />

processing<br />

Safety Integrated o<br />

(only subordinate) (option)<br />

(option)<br />

I/O interfacing<br />

Central/distributed<br />

User know-how<br />

/ - / / o / - /<br />

Preconfigured, turnkey<br />

Previous knowledge<br />

PLC<br />

-<br />

<strong>PC</strong> - -<br />

HMI<br />

Openness<br />

- o o o<br />

Openness<br />

Integration of C++<br />

programs<br />

Further processing of<br />

data using external<br />

programs via O<strong>PC</strong> on a<br />

hardware platform<br />

- -<br />

Modularization with<br />

distributed intelligence<br />

(CBA)<br />

Integration of PLC and<br />

HMI on one hardware<br />

platform<br />

-<br />

-<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Up to<br />

(depending on<br />

processor)<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/175<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Embedded Controller<br />

EC31<br />

■ Overview<br />

Get off to a fast start in automation solutions with embedded<br />

<strong>PC</strong> platforms.<br />

- Ready-to-use SIMATIC WinAC RTX or WinAC RTX F<br />

preinstalled on EC31<br />

- Prepared for use in a SIMATIC environment with PROFINET<br />

and Industrial Ethernet<br />

- Commissioning by specialist automation personnel as with<br />

the S7-300<br />

- Configuring and programming with SIMATIC <strong>ST</strong>EP 7 over<br />

Industrial Ethernet<br />

- Optional visualization<br />

Modular expansion capability:<br />

Central expansion with<br />

- S7-300 I/O (SM modules of S7-300)<br />

- Expansion modules for additional <strong>PC</strong> interfaces, e. g. DVI-I,<br />

USB, Gigabit Ethernet networks and memory card slots, as<br />

well as <strong>PC</strong>I-104<br />

Rugged operation<br />

- Hard-disk-free operation based on flash disk and Windows<br />

Embedded Standard<br />

- Fan-free operation<br />

Flexibility of a <strong>PC</strong>-based automation environment<br />

- Free memory space on flash disk can be used for other <strong>PC</strong><br />

applications<br />

- Use of WinAC ODK with SIMATIC WinAC RTX and<br />

WinAC RTX F (read-only in safety-related program part)<br />

- Connection option for USB devices<br />

- Memory capacity expandable using multimedia card<br />

Data retentivity for WinAC RTX and RTX F without<br />

uninterruptible power supply (UPS)<br />

5/176<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Application<br />

The EC31-RTX combines the advantages of <strong>PC</strong>-based control<br />

solutions with those of the conventional PLC world: It offers the<br />

flexibility for integrating various tasks of an automation solution<br />

on a single hardware platform. The fanless and diskless design<br />

of the EC31 allows the use of the solution directly at the machine<br />

in harsh environments. Using the integrated Ethernet and<br />

PROFINET interfaces, the system can be integrated into existing<br />

automation environments with little effort.<br />

The S7-mEC is the preferred platform if the following criteria for<br />

automation solutions must be fulfilled:<br />

Modular use, expandable<br />

"Headless operation" – without integrated display:<br />

Operation with remote screen using the SIMATIC Thin Client<br />

Integration of different tasks such as control, visualization,<br />

technology functions, or data processing in one hardware unit<br />

Use of application-specific hardware and software<br />

Use at machine level<br />

Safety functions up to SIL 3 according to IEC 61508/62061 or<br />

according to EN ISO 13849-1 up to PL e with WinAC RTX F


■ Design<br />

The S7-mEC automation system can comprise the following<br />

components:<br />

EC31 controller in the following order versions:<br />

- EC31 with Software Development Kit (SDK)<br />

-EC31-RTX<br />

-EC31-RTX F<br />

- EC31-HMI/RTX<br />

S7-300 signal modules<br />

Extension modules for the central rack with additional<br />

<strong>PC</strong> interfaces:<br />

-EM <strong>PC</strong>:<br />

The extension module for additional DVI-I, USB, Gigabit<br />

Ethernet interfaces, serial interfaces and memory card slots.<br />

- EM <strong>PC</strong>I-104:<br />

The extension module for holding up to 3 <strong>PC</strong> cards in the<br />

<strong>PC</strong>I-104 Standard.<br />

The hardware of the EC31 features:<br />

1.2 GHz Intel CoreDuo processor<br />

1 GB RAM, 4 GB flash disk<br />

integrated PROFINET interface (2 ports)<br />

integrated Ethernet interface (1 port)<br />

2 x USB<br />

1 x multimedia card slot<br />

Memory for retentive data, 512 KB without UPS<br />

(256 KB are supported for EC31 with SDK)<br />

Windows Embedded Standard 2009<br />

EC31-RTX features the following additional software:<br />

SIMATIC WinAC RTX 2010<br />

SIMATIC SOFTNET-S7 Lean incl. SIMATIC NET O<strong>PC</strong> Server<br />

EC31-RTX F also has the following software:<br />

SIMATIC WinAC RTX F 2010<br />

EC31-HMI/RTX also features:<br />

WinCC flexible 2008 RT visualization system<br />

Optional<br />

SIMATIC WinAC Open Development Kit (ODK):<br />

- For integrating C/C++ code in SIMATIC WinAC RTX.<br />

- For integrating external software (technology programs)<br />

or <strong>PC</strong> components (e. g. scanners, <strong>PC</strong> cards).<br />

■ Mode of operation<br />

The SIMATIC WinAC RTX handles the actual control task and<br />

execution of the user program. It coordinates the necessary<br />

input and output of process values through the lower-level<br />

PROFINET fieldbus system and provides the process values for<br />

visualization and data processing tasks.<br />

The distributed I/O connection is made via PROFINET, for which<br />

the integrated interface (2 ports, switched) of the EC31 is used.<br />

By using the IO modules of the S7-300 (SM modules), the IO can<br />

also be connected centrally and, if necessary, extended as in<br />

the case of the S7-300. If required, additional <strong>PC</strong> interfaces are<br />

available via the extension modules.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Embedded Controller<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

EC31<br />

■ Function<br />

Control:<br />

For the optimum control of processes with WinAC RTX, several<br />

processing levels are available:<br />

- Cyclic program processing<br />

- Interrupt processing<br />

- Time and date-controlled processing<br />

Functional safety with WinAC RTX F for EC31-RTX F:<br />

The functional safety is implemented by means of targeted<br />

safety functions in the software. Safety functions are<br />

implemented with S7 Distributed Safety, to place the plant in a<br />

safe state or to hold it in a safe state. The safety functions are<br />

mainly included in the following components:<br />

- in the safety-related user program (safety program)<br />

in WinLC RTX F<br />

- in the fail-safe inputs and outputs (F I/O).<br />

The F I/O ensures reliable processing of the field information<br />

(emergency stop pushbutton, light barriers, motor control).<br />

It features all the hardware and software components required<br />

for reliable processing, according to the required safety class.<br />

The user only programs the user safety functions. The safety<br />

functions for the process can be implemented with a user<br />

safety function or a system-internal fault reaction function.<br />

If the F system is unable to execute the actual user safety<br />

function, it will execute the fault response function: e. g.<br />

deactivation of the associated outputs and, if appropriate,<br />

F-CPU in <strong>ST</strong>OP.<br />

Retentivity:<br />

The controller can back up 512 KB of retentive data on an<br />

integrated, non-volatile memory, without the need for a UPS.<br />

Total retentivity of all process values of SIMATIC WinAC RTX<br />

can be achieved with a generally available UPS.<br />

Access to process values:<br />

The SIMATIC NET O<strong>PC</strong> server supplied with EC31-RTX<br />

permits open access to all process values. Visualization<br />

systems or data processing systems can be linked to<br />

SIMATIC WinAC RTX via this interface.<br />

Communication:<br />

The Windows Automation Center (WinAC) is programmed with<br />

SIMATIC <strong>ST</strong>EP 7 via the integrated Industrial Ethernet<br />

interface. The SIMATIC NET SOFTNET Lean communication<br />

package is pre-installed for this purpose.<br />

Use of other software:<br />

The customer can install supporting software products.<br />

Windows Embedded Standard is designed so that typical<br />

add-on packages can be installed.<br />

5/177<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Embedded Controller<br />

EC31<br />

■ Technical specifications<br />

Product type<br />

designation<br />

Product version<br />

Hardware product<br />

version<br />

5/178<br />

6ES7 677-1DD10-<br />

0BA0<br />

SIMATIC S7-mEC,<br />

EC31<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6ES7 677-1DD10-<br />

0BB0<br />

S7-mEC, EC31-<br />

RTX<br />

6ES7 677-1FD00-<br />

0FB0<br />

S7-mEC, EC31-<br />

RTX F<br />

6ES7 677-1DD10-<br />

0BF0<br />

S7-mEC, EC31-<br />

HMI/RTX 128PT<br />

6ES7 677-1DD10-<br />

0BG0<br />

S7-mEC, EC31-<br />

HMI/RTX 512PT<br />

01 01 04 01 01 01<br />

Firmware version V2.0 V2.0 V1.3 V2.0 V2.0 V2.0<br />

<strong>PC</strong> configuration<br />

Computer platform SIMATIC S7<br />

modular<br />

embedded<br />

controller<br />

Processor selection Intel Core Duo 1.2<br />

GHz<br />

SIMATIC S7<br />

modular<br />

embedded<br />

controller<br />

Intel Core Duo 1.2<br />

GHz<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC S7<br />

modular<br />

embedded<br />

controller<br />

Intel Core Duo 1.2<br />

GHz<br />

SIMATIC S7<br />

modular<br />

embedded<br />

controller<br />

Intel Core Duo 1.2<br />

GHz<br />

SIMATIC S7<br />

modular<br />

embedded<br />

controller<br />

Intel Core Duo 1.2<br />

GHz<br />

6ES7 677-1DD10-<br />

0BH0<br />

S7-mEC, EC31-<br />

HMI/RTX 2048PT<br />

SIMATIC S7<br />

modular<br />

embedded<br />

controller<br />

Intel Core Duo 1.2<br />

GHz<br />

Main memory 1 GB RAM 1 GB RAM 1 GB RAM 1 GB RAM 1 GB RAM 1 GB RAM<br />

Flash Disk 4 GB 4 GB 2 GB 4 GB 4 GB 4 GB<br />

Operating systems Windows<br />

Windows<br />

Windows XP Windows<br />

Windows<br />

Windows<br />

Embedded Embedded embedded SP2 Embedded Embedded Embedded<br />

Installed software<br />

Standard 2009 Standard 2009 FP2007<br />

Standard 2009 Standard 2009 Standard 2009<br />

Visualization WinCC flexible RT WinCC flexible RT WinCC flexible RT<br />

2008 SP2, incl. 2008 SP2, incl. 2008 SP2, incl.<br />

Sm@rtAccess, Sm@rtAccess, Sm@rtAccess,<br />

recipes, archives recipes, archives recipes, archives<br />

options<br />

options<br />

options<br />

Control SIMATIC WinAC SIMATIC WinAC SIMATIC WinAC SIMATIC WinAC SIMATIC WinAC<br />

RTX 2010<br />

RTX F 2009 RTX 2010<br />

RTX 2010<br />

RTX 2010<br />

Communication<br />

Power losses<br />

Yes Yes Yes Yes Yes<br />

Power loss, typ.<br />

Memory<br />

34 W 34 W 34 W 34 W 34 W 34 W<br />

Memory type 256 KB non- 512 KB non- 512 KB non- 512 KB non- 512 KB non- 512 KB nonvolatile<br />

memory for volatile memory for volatile memory for volatile memory for volatile memory for volatile memory for<br />

CPU-blocks<br />

DB<br />

retentive data retentive data retentive data retentive data retentive data retentive data<br />

Number, max. Max. code size Max. code size Max. code size Max. code size Max. code size<br />

and max. data and max. data and max. data and max. data and max. data<br />

size: 4 MB each size: 4 MB each size: 4 MB each size: 4 MB each size: 4 MB each<br />

Size, max. 64 Kibyte 64 Kibyte 64 Kibyte 64 Kibyte 64 Kibyte


■ Technical specifications (continued)<br />

Product type<br />

designation<br />

6ES7 677-1DD10-<br />

0BA0<br />

SIMATIC S7-mEC,<br />

EC31<br />

6ES7 677-1DD10-<br />

0BB0<br />

S7-mEC, EC31-<br />

RTX<br />

CPU-blocks<br />

(continued)<br />

FB<br />

Number, max. Max. code size<br />

and max. data<br />

size: 4 MB each<br />

Max. code size<br />

and max. data<br />

size: 4 MB each<br />

Max. code size<br />

and max. data<br />

size: 4 MB each<br />

<strong>PC</strong>-based Automation<br />

Embedded Controller<br />

Max. code size<br />

and max. data<br />

size: 4 MB each<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

EC31<br />

Max. code size<br />

and max. data<br />

size: 4 MB each<br />

Size, max. 64 Kibyte 64 Kibyte 64 Kibyte 64 Kibyte 64 Kibyte<br />

FC<br />

Number, max. Max. code size<br />

and max. data<br />

size: 4 MB each<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6ES7 677-1FD00-<br />

0FB0<br />

S7-mEC, EC31-<br />

RTX F<br />

Max. code size<br />

and max. data<br />

size: 4 MB each<br />

6ES7 677-1DD10-<br />

0BF0<br />

S7-mEC, EC31-<br />

HMI/RTX 128PT<br />

Max. code size<br />

and max. data<br />

size: 4 MB each<br />

6ES7 677-1DD10-<br />

0BG0<br />

S7-mEC, EC31-<br />

HMI/RTX 512PT<br />

Max. code size<br />

and max. data<br />

size: 4 MB each<br />

6ES7 677-1DD10-<br />

0BH0<br />

S7-mEC, EC31-<br />

HMI/RTX 2048PT<br />

Max. code size<br />

and max. data<br />

size: 4 MB each<br />

Size, max.<br />

OB<br />

64 Kibyte 64 Kibyte 64 Kibyte 64 Kibyte 64 Kibyte<br />

Size, max. 64 Kibyte 64 Kibyte 64 Kibyte 64 Kibyte 64 Kibyte<br />

Number of startup<br />

OBs<br />

2; OB 100, 102 2; OB 100, 102 2; OB 100, 102 2; OB 100, 102 2; OB 100, 102<br />

Number of<br />

7; OB <strong>80</strong>, 82-85, 7; OB <strong>80</strong>, 82-85, 7; OB <strong>80</strong>, 82-85, 7; OB <strong>80</strong>, 82-85, 7; OB <strong>80</strong>, 82-85,<br />

asynchronous error<br />

OBs<br />

86, 88<br />

86, 88<br />

86, 88<br />

86, 88<br />

86, 88<br />

Number of<br />

synchronous error<br />

OBs<br />

2; OB 121, 122 2; OB 121, 122 2; OB 121, 122 2; OB 121, 122 2; OB 121, 122<br />

Nesting depth<br />

per priority class 24 24 24 24 24<br />

additional within an<br />

error OB<br />

CPU processing<br />

times<br />

24 24 24 24 24<br />

for bit operations,<br />

min.<br />

0.004 µs; typ. 0.004 µs; typ. 0.004 µs; typ. 0.004 µs; typ. 0.004 µs; typ.<br />

for fixed point arithmetic,<br />

min.<br />

0.003 µs; typ. 0.003 µs; typ. 0.003 µs; typ. 0.003 µs; typ. 0.003 µs; typ.<br />

for floating point<br />

arithmetic, min.<br />

Counters, timers<br />

and their retentivity<br />

S7 counter<br />

0.004 µs; typ. 0.004 µs; typ. 0.004 µs; typ. 0.004 µs; typ. 0.004 µs; typ.<br />

Number<br />

Retentivity<br />

2048 2048 2048 2048 2048<br />

- can be set Yes Yes Yes Yes Yes<br />

-lower limit 0 0 0 0 0<br />

- upper limit 2047 2047 2047 2047 2047<br />

-preset<br />

Counting range<br />

8 8 8 8 8<br />

- can be set Yes Yes Yes Yes Yes<br />

-lower limit 0 0 0 0 0<br />

- upper limit 999 999 999 999 999<br />

5/179<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Embedded Controller<br />

EC31<br />

■ Technical specifications (continued)<br />

Product type<br />

designation<br />

Counters, timers<br />

and their retentivity<br />

(continued)<br />

IEC counter<br />

present Yes Yes Yes Yes Yes<br />

Type<br />

S7 times<br />

SFB SFB SFB SFB SFB<br />

Number<br />

Retentivity<br />

2048 2048 2048 2048 2048<br />

- can be set Yes Yes Yes Yes Yes<br />

-lower limit 0 0 0 0 0<br />

- upper limit<br />

Time range<br />

2047 2047 2047 2047 2047<br />

-lower limit 10 ms 10 ms 10 ms 10 ms 10 ms<br />

- upper limit<br />

IEC timer<br />

9990s 9990s 9990s 9990s 9990s<br />

present Yes Yes Yes Yes Yes<br />

Type<br />

Data areas and<br />

their retentivity<br />

SFB SFB SFB SFB SFB<br />

retentive data area,<br />

total<br />

Flag<br />

512 KB 512 KB 512 KB 512 KB 512 KB<br />

Number, max. 16 Kibyte 16 Kibyte 16 Kibyte 16 Kibyte 16 Kibyte<br />

Retentivity preset MB 0 to MB 15 MB 0 to MB 15 MB 0 to MB 15 MB 0 to MB 15 MB 0 to MB 15<br />

Number of clock<br />

memories<br />

Address area<br />

I/O address area<br />

8 8 8 8 8<br />

Inputs 16 Kibyte 16 Kibyte 16 Kibyte 16 Kibyte 16 Kibyte<br />

Outputs<br />

of which,<br />

distributed<br />

16 Kibyte 16 Kibyte 16 Kibyte 16 Kibyte 16 Kibyte<br />

-Inputs 8Kibyte 8Kibyte 8Kibyte 8Kibyte 8Kibyte<br />

-Outputs<br />

Process image<br />

8Kibyte 8Kibyte 8Kibyte 8Kibyte 8Kibyte<br />

Inputs, adjustable 16 Kibyte 16 Kibyte 8Kibyte 8Kibyte 8Kibyte<br />

Outputs,<br />

adjustable<br />

16 Kibyte 16 Kibyte 8Kibyte 8Kibyte 8Kibyte<br />

Inputs, default 512 byte 512 byte 512 byte 512 byte 512 byte<br />

Outputs, default<br />

Subprocess images<br />

512 byte 512 byte 512 byte 512 byte 512 byte<br />

Number of<br />

subprocess<br />

images, max.<br />

15 15 15 15 15<br />

Digital channels<br />

Inputs 128 000 128 000 128 000 128 000 128 000<br />

Outputs<br />

Analog channels<br />

128 000 128 000 128 000 128 000 128 000<br />

Inputs <strong>80</strong>00 <strong>80</strong>00 <strong>80</strong>00 <strong>80</strong>00 <strong>80</strong>00<br />

Outputs <strong>80</strong>00 <strong>80</strong>00 <strong>80</strong>00 <strong>80</strong>00 <strong>80</strong>00<br />

5/1<strong>80</strong><br />

6ES7 677-1DD10-<br />

0BA0<br />

SIMATIC S7-mEC,<br />

EC31<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6ES7 677-1DD10-<br />

0BB0<br />

S7-mEC, EC31-<br />

RTX<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6ES7 677-1FD00-<br />

0FB0<br />

S7-mEC, EC31-<br />

RTX F<br />

6ES7 677-1DD10-<br />

0BF0<br />

S7-mEC, EC31-<br />

HMI/RTX 128PT<br />

6ES7 677-1DD10-<br />

0BG0<br />

S7-mEC, EC31-<br />

HMI/RTX 512PT<br />

6ES7 677-1DD10-<br />

0BH0<br />

S7-mEC, EC31-<br />

HMI/RTX 2048PT


■ Technical specifications (continued)<br />

Product type<br />

designation<br />

Time of day<br />

Clock<br />

Hardware clock<br />

(real-time clock)<br />

Yes; Resolution:<br />

1 s<br />

Yes; Resolution:<br />

1 s<br />

Yes; Resolution:<br />

1 s<br />

<strong>PC</strong>-based Automation<br />

Embedded Controller<br />

Yes; Resolution:<br />

1 s<br />

Clock synchronization<br />

supported Yes Yes Yes Yes Yes<br />

to <strong>PC</strong>-CP, slave Yes Yes Yes Yes Yes<br />

on Ethernet via NTP Yes Yes Yes Yes Yes<br />

Interfaces<br />

Industrial Ethernet<br />

Industrial Ethernet<br />

interface<br />

6ES7 677-1DD10-<br />

0BA0<br />

SIMATIC S7-mEC,<br />

EC31<br />

X1: 2 ports<br />

10/100 Mbit/s<br />

(ERTEC-based)<br />

X2: 1 port<br />

10/100 Mbit/s<br />

6ES7 677-1DD10-<br />

0BB0<br />

S7-mEC, EC31-<br />

RTX<br />

X1: 2 ports<br />

10/100 Mbit/s<br />

(ERTEC-based)<br />

X2: 1 port<br />

10/100 Mbit/s<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6ES7 677-1FD00-<br />

0FB0<br />

S7-mEC, EC31-<br />

RTX F<br />

6ES7 677-1DD10-<br />

0BF0<br />

S7-mEC, EC31-<br />

HMI/RTX 128PT<br />

X1: 2 ports<br />

10/100 Mbit/s<br />

(ERTEC-based)<br />

X2: 1 port<br />

10/100 Mbit/s<br />

6ES7 677-1DD10-<br />

0BG0<br />

S7-mEC, EC31-<br />

HMI/RTX 512PT<br />

X1: 2 ports<br />

10/100 Mbit/s<br />

(ERTEC-based)<br />

X2: 1 port<br />

10/100 Mbit/s<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

EC31<br />

Yes; Resolution:<br />

1 s<br />

X1: 2 ports<br />

10/100 Mbit/s<br />

(ERTEC-based)<br />

X2: 1 port<br />

10/100 Mbit/s<br />

1st interface<br />

Type of interface PROFINET PROFINET PROFINET PROFINET PROFINET<br />

Physics 2x RJ45 2x RJ45 2x RJ45 2x RJ45 2x RJ45<br />

automatic detection<br />

of transmission<br />

speed<br />

Yes Yes Yes Yes Yes<br />

Autonegotiation Yes Yes Yes Yes Yes<br />

Autocrossing Yes Yes Yes Yes Yes<br />

Number of<br />

connection<br />

resources<br />

32 32 32 32 32<br />

Functionality<br />

MPI No<br />

DP master No<br />

DP slave No<br />

PROFINET IO<br />

Device<br />

No No No No No<br />

PROFINET IO<br />

Controller<br />

Yes Yes Yes Yes Yes<br />

PROFINET CBA Yes Yes Yes Yes Yes<br />

Point-to-point<br />

connection<br />

PROFINET IO<br />

Controller<br />

Services<br />

No<br />

- PG/OP<br />

communication<br />

Yes Yes Yes Yes Yes<br />

- S7 routing Yes Yes Yes Yes Yes<br />

- S7 communication<br />

Yes Yes Yes Yes Yes<br />

- Isochronous<br />

mode<br />

Yes No Yes Yes Yes<br />

Number of<br />

connectable IO<br />

devices, max.<br />

256 256 256 256 256<br />

Max. number of<br />

connectable IO<br />

devices for RT<br />

256 256 256 256<br />

- of which in line,<br />

max.<br />

256 256 256 256<br />

Number of IO<br />

devices with IRT<br />

and the option<br />

"high flexibility"<br />

256 64 256 256 256<br />

- of which in line,<br />

max.<br />

61 61 61 61<br />

6ES7 677-1DD10-<br />

0BH0<br />

S7-mEC, EC31-<br />

HMI/RTX 2048PT<br />

5/181<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Embedded Controller<br />

EC31<br />

■ Technical specifications (continued)<br />

Product type<br />

designation<br />

PROFINET IO<br />

Controller<br />

Number of IO<br />

Devices with IRT<br />

and the option<br />

"high performance",<br />

max.<br />

256 256 256 256<br />

- of which in line,<br />

max.<br />

64 64 64 64<br />

IRT, supported Yes Yes Yes Yes Yes<br />

Prioritized startup<br />

supported<br />

Yes Yes Yes Yes Yes<br />

- Number of IO<br />

Devices, max.<br />

32 32 32 32 32<br />

Activation/deactivation<br />

of IO<br />

Devices<br />

Yes Yes Yes Yes Yes<br />

- Number of IO<br />

Devices that can<br />

be simultaneously<br />

activated/<br />

deactivated, max.<br />

8 8 8 8 8<br />

IO Devices<br />

changing during<br />

operation (partner<br />

ports), supported<br />

Yes Yes Yes Yes Yes<br />

- Max. number of<br />

IO devices per<br />

tool<br />

8 8 8 8 8<br />

Device<br />

replacement<br />

without swap<br />

medium<br />

Yes Yes Yes Yes<br />

Send cycles Adjustable:<br />

250 µs, 500 µs and<br />

1ms<br />

Updating times 250 µs - 128 ms<br />

(at signal cycle<br />

250 µs); 500µs -<br />

256 ms (at signal<br />

cycle 500 µs);<br />

1 ms - 512 ms (at<br />

signal cycle 1 ms)<br />

5/182<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Adjustable:<br />

250 µs, 500 µs and<br />

1ms<br />

250 µs - 128 ms<br />

(at signal cycle<br />

250 µs); 500µs -<br />

256 ms (at signal<br />

cycle 500 µs);<br />

1 ms - 512 ms (at<br />

signal cycle 1 ms)<br />

Adjustable:<br />

250 µs, 500 µs and<br />

1 ms<br />

250 µs - 128 ms<br />

(at signal cycle<br />

250 µs); 500µs -<br />

256 ms (at signal<br />

cycle 500 µs);<br />

1 ms - 512 ms (at<br />

signal cycle 1 ms)<br />

Adjustable:<br />

250 µs, 500 µs and<br />

1 ms<br />

250 µs - 128 ms<br />

(at signal cycle<br />

250 µs); 500µs -<br />

256 ms (at signal<br />

cycle 500 µs);<br />

1 ms - 512 ms (at<br />

signal cycle 1 ms)<br />

Adjustable:<br />

250 µs, 500 µs and<br />

1 ms<br />

250 µs - 128 ms<br />

(at signal cycle<br />

250 µs); 500µs -<br />

256 ms (at signal<br />

cycle 500 µs);<br />

1 ms - 512 ms (at<br />

signal cycle 1 ms)<br />

Address area<br />

- Inputs, max. 16 Kibyte 16 Kibyte 16 Kibyte 16 Kibyte 16 Kibyte<br />

- Outputs, max. 16 Kibyte 16 Kibyte 16 Kibyte 16 Kibyte 16 Kibyte<br />

User data per<br />

address area, max.<br />

2Kibyte 2Kibyte 2Kibyte 2Kibyte 2Kibyte<br />

-User data<br />

consistency, max.<br />

Open IE communication<br />

256 byte 256 byte 256 byte 256 byte 256 byte<br />

Open IE communication,<br />

supported<br />

Yes Yes Yes Yes Yes<br />

Number of<br />

connections, max.<br />

32 32 32 32 32<br />

Local port numbers<br />

used at the system<br />

end<br />

6ES7 677-1DD10-<br />

0BA0<br />

SIMATIC S7-mEC,<br />

EC31<br />

6ES7 677-1DD10-<br />

0BB0<br />

S7-mEC, EC31-<br />

RTX<br />

0, 20, 21, 23, 25,<br />

<strong>80</strong>, 102, 135, 161,<br />

<strong>80</strong><strong>80</strong>, 34962,<br />

34963, 34964,<br />

65532, 65533,<br />

65534, 65535<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6ES7 677-1FD00-<br />

0FB0<br />

S7-mEC, EC31-<br />

RTX F<br />

0, 20, 21, 23, 25,<br />

<strong>80</strong>, 102, 135, 161,<br />

<strong>80</strong><strong>80</strong>, 34962,<br />

34963, 34964,<br />

65532, 65533,<br />

65534, 65535<br />

6ES7 677-1DD10-<br />

0BF0<br />

S7-mEC, EC31-<br />

HMI/RTX 128PT<br />

0, 20, 21, 23, 25,<br />

<strong>80</strong>, 102, 135, 161,<br />

<strong>80</strong><strong>80</strong>, 34962,<br />

34963, 34964,<br />

65532, 65533,<br />

65534, 65535<br />

6ES7 677-1DD10-<br />

0BG0<br />

S7-mEC, EC31-<br />

HMI/RTX 512PT<br />

0, 20, 21, 23, 25,<br />

<strong>80</strong>, 102, 135, 161,<br />

<strong>80</strong><strong>80</strong>, 34962,<br />

34963, 34964,<br />

65532, 65533,<br />

65534, 65535<br />

6ES7 677-1DD10-<br />

0BH0<br />

S7-mEC, EC31-<br />

HMI/RTX 2048PT<br />

0, 20, 21, 23, 25,<br />

<strong>80</strong>, 102, 135, 161,<br />

<strong>80</strong><strong>80</strong>, 34962,<br />

34963, 34964,<br />

65532, 65533,<br />

65534, 65535


■ Technical specifications (continued)<br />

Product type<br />

designation<br />

PROFINET functions<br />

Detection of<br />

accessible nodes,<br />

supported<br />

Assignment of the<br />

IP address,<br />

supported<br />

Assignment of the<br />

device name,<br />

supported<br />

Topology recog-<br />

Yes; LLDP, LLDP<br />

nition, supported<br />

MIB, SNMP<br />

Extended network<br />

Yes; Standard<br />

diagnostics with<br />

MIB II, SNMP<br />

Standard MIB II,<br />

supported<br />

2nd interface<br />

Type of interface Integrated<br />

Ethernet interface<br />

<strong>PC</strong>-based Automation<br />

Embedded Controller<br />

Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP<br />

Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP<br />

Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP<br />

Yes; LLDP, LLDP<br />

MIB, SNMP<br />

Yes; Standard<br />

MIB II, SNMP<br />

Integrated<br />

Ethernet interface<br />

Yes; LLDP, LLDP<br />

MIB, SNMP<br />

Yes; Standard<br />

MIB II, SNMP<br />

Integrated<br />

Ethernet interface<br />

Yes; LLDP, LLDP<br />

MIB, SNMP<br />

Yes; Standard<br />

MIB II, SNMP<br />

Integrated<br />

Ethernet interface<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

EC31<br />

Yes; LLDP, LLDP<br />

MIB, SNMP<br />

Yes; Standard<br />

MIB II, SNMP<br />

Integrated<br />

Ethernet interface<br />

Physics Ethernet RJ45 Ethernet RJ45 Ethernet RJ45 Ethernet RJ45 Ethernet RJ45<br />

automatic detection<br />

of transmission<br />

speed<br />

Yes Yes Yes Yes Yes<br />

Autonegotiation Yes Yes Yes Yes Yes<br />

Autocrossing No No No No No<br />

Number of<br />

connection<br />

resources<br />

32 32 32 32 32<br />

Functionality<br />

PROFINET IO<br />

Controller<br />

No No No No No<br />

PROFINET IO<br />

Device<br />

No No No No No<br />

PROFINET CBA<br />

PROFINET functions<br />

No No No No No<br />

Detection of<br />

accessible nodes,<br />

supported<br />

Yes; DCP Yes; DCP Yes; DCP Yes; DCP<br />

Assignment of the<br />

IP address,<br />

supported<br />

Yes; DCP Yes; DCP Yes; DCP Yes; DCP<br />

Assignment of the<br />

device name,<br />

supported<br />

Yes; DCP Yes; DCP Yes; DCP Yes; DCP<br />

Topology recog-<br />

Yes; LLDP,<br />

Yes; LLDP, Yes; LLDP, Yes; LLDP,<br />

nition, supported<br />

LLDP MIB, SNMP<br />

LLDP MIB, SNMP LLDP MIB, SNMP LLDP MIB, SNMP<br />

Extended network<br />

diagnostics with<br />

Standard MIB II,<br />

supported<br />

6ES7 677-1DD10-<br />

0BA0<br />

SIMATIC S7-mEC,<br />

EC31<br />

6ES7 677-1DD10-<br />

0BB0<br />

S7-mEC, EC31-<br />

RTX<br />

Yes; Standard<br />

MIB II, SNMP<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6ES7 677-1FD00-<br />

0FB0<br />

S7-mEC, EC31-<br />

RTX F<br />

6ES7 677-1DD10-<br />

0BF0<br />

S7-mEC, EC31-<br />

HMI/RTX 128PT<br />

Yes; Standard<br />

MIB II, SNMP<br />

6ES7 677-1DD10-<br />

0BG0<br />

S7-mEC, EC31-<br />

HMI/RTX 512PT<br />

Yes; Standard<br />

MIB II, SNMP<br />

6ES7 677-1DD10-<br />

0BH0<br />

S7-mEC, EC31-<br />

HMI/RTX 2048PT<br />

Yes; Standard<br />

MIB II, SNMP<br />

5/183<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Embedded Controller<br />

EC31<br />

■ Technical specifications (continued)<br />

Product type<br />

designation<br />

Communication<br />

functions<br />

PG/OP communication<br />

Global data communication<br />

Yes Yes Yes Yes Yes<br />

supported<br />

S7 basic communication<br />

No No No No No<br />

supported<br />

S7 communication<br />

No No No No No<br />

supported Yes Yes Yes Yes Yes<br />

as server Yes Yes Yes Yes Yes<br />

as client Yes Yes Yes Yes Yes<br />

Open IE communication<br />

TCP/IP Yes; Via integrated<br />

PROFINET<br />

interface (X1) and<br />

loadable FBs<br />

-Number of<br />

connections,<br />

max.<br />

5/184<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Yes; Via integrated<br />

PROFINET<br />

interface and<br />

loadable FBs<br />

Yes; Via integrated<br />

PROFINET<br />

interface (X1) and<br />

loadable FBs<br />

Yes; Via integrated<br />

PROFINET<br />

interface (X1) and<br />

loadable FBs<br />

32 32 32 32 32<br />

Yes; Via integrated<br />

PROFINET<br />

interface (X1) and<br />

loadable FBs<br />

- Data length, max. 32 Kibyte 8192byte 32 Kibyte 32 Kibyte 32 Kibyte<br />

ISO-on-TCP<br />

(RFC1006)<br />

Yes; Via integrated<br />

PROFINET<br />

interface (X1) and<br />

loadable FBs<br />

No Yes; Via integrated<br />

PROFINET<br />

interface (X1) and<br />

loadable FBs<br />

Yes; Via integrated<br />

PROFINET<br />

interface (X1) and<br />

loadable FBs<br />

Yes; Via integrated<br />

PROFINET<br />

interface (X1) and<br />

loadable FBs<br />

-Number of<br />

connections,<br />

max.<br />

32 32 32 32<br />

- Data length, max. 32 Kibyte 32 Kibyte 32 Kibyte 32 Kibyte<br />

UDP Yes; Via integrated<br />

PROFINET<br />

interface (X1) and<br />

loadable FBs<br />

-Number of<br />

connections,<br />

max.<br />

Yes; Via integrated<br />

PROFINET<br />

interface and<br />

loadable FBs<br />

Yes; Via integrated<br />

PROFINET<br />

interface (X1) and<br />

loadable FBs<br />

Yes; Via integrated<br />

PROFINET<br />

interface (X1) and<br />

loadable FBs<br />

32 32 32 32 32<br />

Yes; Via integrated<br />

PROFINET<br />

interface (X1) and<br />

loadable FBs<br />

- Data length, max.<br />

Number of connections<br />

1472byte 1472byte 1472byte 1472byte 1472byte<br />

overall 64 64 64 64 64<br />

S7 message<br />

functions<br />

Number of login<br />

stations for message<br />

functions, max.<br />

Process diagnostic<br />

messages<br />

6ES7 677-1DD10-<br />

0BA0<br />

SIMATIC S7-mEC,<br />

EC31<br />

6ES7 677-1DD10-<br />

0BB0<br />

S7-mEC, EC31-<br />

RTX<br />

62; The alarm<br />

functions cannot<br />

currently be used<br />

for central bus<br />

modules<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6ES7 677-1FD00-<br />

0FB0<br />

S7-mEC, EC31-<br />

RTX F<br />

62; The alarm<br />

functions cannot<br />

currently be used<br />

for central bus<br />

modules<br />

6ES7 677-1DD10-<br />

0BF0<br />

S7-mEC, EC31-<br />

HMI/RTX 128PT<br />

62; The alarm<br />

functions cannot<br />

currently be used<br />

for central bus<br />

modules<br />

6ES7 677-1DD10-<br />

0BG0<br />

S7-mEC, EC31-<br />

HMI/RTX 512PT<br />

62; The alarm<br />

functions cannot<br />

currently be used<br />

for central bus<br />

modules<br />

6ES7 677-1DD10-<br />

0BH0<br />

S7-mEC, EC31-<br />

HMI/RTX 2048PT<br />

62; The alarm<br />

functions cannot<br />

currently be used<br />

for central bus<br />

modules<br />

Yes; Alarm_S Yes; Alarm_S Yes; Alarm_S Yes; Alarm_S Yes; Alarm_S


■ Technical specifications (continued)<br />

Product type<br />

designation<br />

6ES7 677-1DD10-<br />

0BA0<br />

SIMATIC S7-mEC,<br />

EC31<br />

6ES7 677-1DD10-<br />

0BB0<br />

S7-mEC, EC31-<br />

RTX<br />

<strong>PC</strong>-based Automation<br />

Embedded Controller<br />

Test commissioning<br />

functions<br />

Status/control<br />

Status/control<br />

variable<br />

Forcing<br />

Yes Yes Yes Yes Yes<br />

Forcing<br />

Diagnostic buffer<br />

No No No No No<br />

present<br />

Ambient conditions<br />

Operating temperature<br />

Yes Yes Yes Yes Yes<br />

Min. 0°C 0°C 0°C 0°C 0°C 0°C<br />

max. 50 °C 50 °C 50 °C 50 °C 50 °C 50 °C<br />

Configuration<br />

Configuration<br />

software<br />

<strong>ST</strong>EP 7 Yes; As of V5.5 +<br />

HW update/iMap<br />

V3.0 SP1<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6ES7 677-1FD00-<br />

0FB0<br />

S7-mEC, EC31-<br />

RTX F<br />

Yes; <strong>ST</strong>EP7 V5.4<br />

SP5 or higher +<br />

HSP135 as basic<br />

requirement for the<br />

HSP178 for WinAC<br />

RTX F 2009 on<br />

Embedded<br />

Controller / iMap<br />

V3.0 SP1<br />

6ES7 677-1DD10-<br />

0BF0<br />

S7-mEC, EC31-<br />

HMI/RTX 128PT<br />

Yes; As of V5.5 +<br />

HW update/iMap<br />

V3.0 SP1<br />

6ES7 677-1DD10-<br />

0BG0<br />

S7-mEC, EC31-<br />

HMI/RTX 512PT<br />

Yes; As of V5.5 +<br />

HW update/iMap<br />

V3.0 SP1<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

EC31<br />

6ES7 677-1DD10-<br />

0BH0<br />

S7-mEC, EC31-<br />

HMI/RTX 2048PT<br />

Yes; As of V5.5 +<br />

HW update/iMap<br />

V3.0 SP1<br />

Programming<br />

Programming<br />

language<br />

-LAD Yes Yes Yes Yes Yes<br />

-FBD Yes Yes Yes Yes Yes<br />

-<strong>ST</strong>L Yes Yes Yes Yes Yes<br />

-SCL Yes Yes Yes Yes Yes<br />

-CFC Yes Yes Yes Yes Yes<br />

- GRAPH Yes Yes Yes Yes Yes<br />

-HiGraph®<br />

Dimensions and<br />

weight<br />

Dimensions<br />

Yes Yes Yes Yes Yes<br />

Width 160 mm 160 mm 160 mm 160 mm 160 mm 160 mm<br />

Height 125 mm 125 mm 125 mm 125 mm 125 mm 125 mm<br />

Depth 115 mm 115 mm 115 mm 115 mm 115 mm 115 mm<br />

5/185<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Embedded Controller<br />

EC31<br />

■ Ordering data Order No. Order No.<br />

SIMATIC S7-modular Embedded<br />

Accessories<br />

Controller<br />

EM <strong>PC</strong>I-104 expansion module A 6ES7 677-1DD40-1AA0<br />

EC31 E 6ES7 677-1DD10-0BA0<br />

For fitting up to 3 additional<br />

Intel CoreDuo 1.2 GHz processor<br />

<strong>PC</strong>I-104 cards<br />

Memory expansion:<br />

1 GB RAM, 4 GB Flash Disk;<br />

EM <strong>PC</strong> expansion module A 6ES7 677-1DD50-2AA0<br />

interfaces:<br />

1 Industrial Ethernet port,<br />

2 PROFINET ports, 2 USB ports,<br />

1 slot for multimedia card;<br />

Software:<br />

Windows Embedded Standard<br />

preinstalled, Software Development<br />

Kit (SDK) for creating<br />

C/C++ applications with<br />

accesses to central I/O modules<br />

Additional connection options:<br />

2 USB interfaces,<br />

1 Gigabit Ethernet interface,<br />

1 serial interface,<br />

1 slot for CF card,<br />

1 slot for SD card/<br />

Micro Memory Card<br />

EC31-RTX<br />

Intel CoreDuo 1.2 GHz processor<br />

Memory expansion:<br />

1 GB RAM, 4 GB Flash Disk;<br />

interfaces:<br />

1 Industrial Ethernet port,<br />

2 PROFINET ports, 2 USB ports,<br />

1 slot for multimedia card;<br />

Software:<br />

Windows Embedded Standard<br />

and WinAC RTX 2010 preinstalled<br />

E 6ES7 677-1DD10-0BB0<br />

EC31-RTX F<br />

Intel CoreDuo 1.2 GHz processor<br />

Memory expansion:<br />

1 GB RAM, 4 GB Flash Disk;<br />

interfaces:<br />

1 Industrial Ethernet port,<br />

2 PROFINET ports, 2 USB ports,<br />

1 slot for multimedia card;<br />

Software:<br />

Windows Embedded Standard<br />

and WinAC RTX F 2010 preinstalled<br />

EC31-HMI/RTX<br />

Intel CoreDuo 1.2 GHz processor<br />

Memory expansion:<br />

1 GB RAM, 4 GB Flash Disk;<br />

interfaces:<br />

1 Industrial Ethernet port,<br />

2 PROFINET ports, 2 USB ports,<br />

1 slot for multimedia card;<br />

Software:<br />

Windows Embedded Standard,<br />

WinAC RTX 2010,<br />

SIMATIC SOFTNET-S7/V7.0 Lean<br />

preinstalled<br />

E 6ES7 677-1FD10-0FB0<br />

With WinCC flexible 2008 RT<br />

128 PT<br />

E 6ES7 677-1DD10-0BF0<br />

With WinCC flexible 2008 RT<br />

512 PT<br />

E 6ES7 677-1DD10-0BG0<br />

With WinCC flexible 2008 RT<br />

2048 PT<br />

E 6ES7 677-1DD10-0BH0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

5/186<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Overview<br />

Get off to a fast start in automation solutions with embedded<br />

<strong>PC</strong> platforms.<br />

- Ready-to-use SIMATIC WinAC RTX or WinAC RTX F<br />

preinstalled on EC31<br />

- Prepared for use in a SIMATIC environment with PROFINET<br />

and Industrial Ethernet<br />

- Commissioning by specialist automation personnel as with<br />

S7-300<br />

- Configuring and programming with SIMATIC <strong>ST</strong>EP 7 over<br />

Industrial Ethernet<br />

- Optional visualization<br />

Modular expansion capability:<br />

Central expansion with<br />

- S7-300 I/O (SM modules of S7-300)<br />

- Expansion modules for additional <strong>PC</strong> interfaces, e. g. DVI-I,<br />

USB, Gigabit Ethernet networking and memory card slots, as<br />

well as <strong>PC</strong>I-104<br />

Rugged operation<br />

- Disk-free operation based on flash disk and Windows XP<br />

embedded<br />

- Fan-free operation<br />

Flexibility of a <strong>PC</strong>-based automation environment<br />

- Free memory space on flash disk can be used for other<br />

<strong>PC</strong> applications<br />

- Use of WinAC ODK with SIMATIC WinAC RTX and<br />

WinAC RTX F (read-only in safety-related program part)<br />

- Connection option for USB devices<br />

- Memory capacity expandable using multimedia card<br />

Data retentivity for WinAC RTX and RTX F without<br />

uninterruptible power supply (UPS)<br />

■ Technical specifications<br />

SIPLUS S7-modular Embedded<br />

Controller EC31<br />

Order No. 6AG1 677-1DD00-4BA0<br />

Order No. based on 6ES7 677-1DD00-0BA0<br />

Ambient temperature range 0 ... +50 °C<br />

Conformal Coating Coating of the printed circuit<br />

boards and the electronic<br />

components<br />

Technical specifications The technical data of the<br />

standard product applies except<br />

for the ambient conditions.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Embedded Controller<br />

SIPLUS S7-modular embedded controller<br />

SIPLUS S7 modular embedded<br />

controller EC31-RTX<br />

Order No. 6AG1 677-1DD00-4BB0<br />

Order No. based on 6ES7 677-1DD00-0BB0<br />

Ambient temperature range 0 ... +50 °C<br />

Conformal coating Coating of the printed circuit<br />

boards and the electronic<br />

components<br />

Technical specifications The technical data of the<br />

standard product applies except<br />

for the ambient conditions.<br />

Ambient conditions<br />

Relative humidity 5 … 100%<br />

Condensation permissible<br />

Air pressure (depending on the<br />

highest positive temperature range<br />

specified)<br />

■ Ordering data Order No.<br />

10<strong>80</strong> ... 795 hPa<br />

(-1000 ... +2000m)<br />

see ambient temperature range<br />

795 ... 658 hPa<br />

(+2000 ... +3500m)<br />

derating 10 K<br />

658 … 540 hPa<br />

(+3500 … +5000m)<br />

derating 20 K<br />

SIPLUS S7 modular embedded<br />

controller<br />

EC31<br />

(medial exposure)<br />

Intel CoreDuo 1.2 GHz processor<br />

Memory expansion:<br />

1 GB RAM, 4 GB flash disk;<br />

Interfaces:<br />

1 Industrial Ethernet port,<br />

2 PROFINET ports, 2 USB ports,<br />

1 multimedia card slot;<br />

Software:<br />

Windows Embedded Standard<br />

pre-installed, Software Development<br />

Kit (SDK) for creating<br />

C/C++ applications with access<br />

to central I/O modules<br />

E 6AG1 677-1DD00-4BA0<br />

EC31-RTX<br />

(medial exposure)<br />

Intel CoreDuo 1.2 GHz processor<br />

Memory expansion:<br />

1 GB RAM, 4 GB flash disk;<br />

Interfaces:<br />

1 Industrial Ethernet port,<br />

2 PROFINET ports, 2 USB ports,<br />

1 multimedia card slot;<br />

Software:<br />

Windows Embedded Standard<br />

and WinAC RTX 2010 preinstalled<br />

Development Kit (SDK) for<br />

creating C/C++ applications with<br />

access to central I/O modules<br />

E 6AG1 677-1DD00-4BB0<br />

Accessories see SIMATIC S7-modular<br />

Embedded Controller<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/187<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Embedded Controller<br />

Expansion modules<br />

■ Overview<br />

Expansion modules for SIMATIC S7-modular Embedded<br />

Controller EC31<br />

- EM <strong>PC</strong>I-104 for additionally accommodating of up to<br />

3 <strong>PC</strong>I-104 cards<br />

- EM <strong>PC</strong> with additional <strong>PC</strong> interfaces and slots for memory<br />

media<br />

5/188<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Application<br />

A SIMATIC S7-modular Embedded Controller EC31 can be<br />

expanded centrally with the EM <strong>PC</strong>I-104 and EM <strong>PC</strong> expansion<br />

modules. Additional DVI-I, USB, Gigabit Ethernet and serial<br />

interfaces are available, as well as memory card slots and<br />

connections for <strong>PC</strong>I-104 cards. This ensures low-overhead<br />

integration into existing automation environments.<br />

■ Design<br />

The expansion modules are connected directly to the EC31.<br />

They offer the following connection/plug-in options:<br />

EM <strong>PC</strong>I-104<br />

Up to 3 <strong>PC</strong>I-104 cards can be inserted<br />

EM <strong>PC</strong><br />

2 USB interfaces<br />

1 Gigabit Ethernet interface<br />

1 serial interface<br />

1 slot for CF card<br />

1 slot for SD card/Micro Memory Card


■ Technical specifications<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Embedded Controller<br />

Expansion modules<br />

6ES7 677-1DD40-1AA0 6ES7 677-1DD50-2AA0<br />

Product type designation<br />

Product version<br />

EM <strong>PC</strong>I-104 EM <strong>PC</strong><br />

Hardware product version<br />

Input current<br />

01 01<br />

from expansion bus<br />

Power losses<br />

100 mA 5<strong>80</strong> mA<br />

Power loss, typ. 2.4 W; Without inserted <strong>PC</strong>I-104 cards 9W<br />

Power loss, max.<br />

Interfaces<br />

14 W<br />

serial interface<br />

Industrial Ethernet<br />

1x V.24 (RS232)<br />

Industrial Ethernet interface<br />

Ambient conditions<br />

Operating temperature<br />

Onboard, 10/100/1000 Mbit, RJ45<br />

Min. 0°C 0°C<br />

max.<br />

Dimensions and weight<br />

Dimensions<br />

50 °C 50 °C<br />

Width 120 mm; Without bus connector Extension-Bus <strong>80</strong> mm; Without bus connector Extension-Bus<br />

Height 125 mm; Without external voltage connecting<br />

terminal<br />

125 mm<br />

Depth 115 mm 115 mm<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/189<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Embedded Controller<br />

Expansion modules<br />

■ Ordering data Order No.<br />

EM <strong>PC</strong>I-104 expansion module<br />

For fitting up to 3 additional<br />

<strong>PC</strong>I-104 cards<br />

A 6ES7 677-1DD40-1AA0<br />

EM <strong>PC</strong> expansion module<br />

Additional connection options:<br />

2 USB interfaces,<br />

1 Gigabit Ethernet interface,<br />

1 serial interface,<br />

1 slot for CF card,<br />

1 slot for SD card/<br />

Micro Memory Card<br />

A 6ES7 677-1DD50-2AA0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

5/190<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Overview<br />

The Embedded Bundles for <strong>PC</strong>-based automation are based on<br />

rugged, fan-free SIMATIC I<strong>PC</strong>s. They are pre-installed,<br />

configured, and ready-to-use with the SIMATIC WinAC RTX (F)<br />

software controller and/or the SIMATIC WinCC/WinCC flexible<br />

visualization software.<br />

Software Packages with WinCC flexible, WinCC or<br />

WinAC RTX (F) together with the corresponding SIMATIC I<strong>PC</strong>.<br />

The following are available:<br />

SIMATIC I<strong>PC</strong> packages with WinCC flexible<br />

SIMATIC I<strong>PC</strong> packages with WinCC<br />

SIMATIC I<strong>PC</strong> packages with WinCC RT Advanced and<br />

WinCC RT Professional<br />

SIMATIC I<strong>PC</strong> packages with WinAC RTX (F).<br />

A Software Package can only be supplied if the same number of<br />

SIMATIC industrial <strong>PC</strong>s is ordered together with the software.<br />

It cannot be ordered subsequently.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Embedded bundles/Software Packages<br />

Embedded bundles/Software packages<br />

■ More information<br />

You can find more information on the Internet at:<br />

www.automation.siemens.com/mcms/pc-based-automation/en/<br />

embedded-bundles<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/191<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Embedded Box <strong>PC</strong> bundles<br />

SIMATIC I<strong>PC</strong>227D bundles<br />

■ Overview<br />

A quick start in automation solutions with embedded <strong>PC</strong><br />

platforms<br />

- SIMATIC WinAC RTX or SIMATIC WinAC RTX F preinstalled<br />

on SIMATIC I<strong>PC</strong>227D and ready for use<br />

- PROFINET RT and Industrial Ethernet pre-configured for use<br />

in a SIMATIC environment<br />

- Optional WinCC RT Advanced for visualization tasks in<br />

parallel with SIMATIC WinAC RTX<br />

- Configuration and programming with SIMATIC <strong>ST</strong>EP 7 via<br />

Industrial Ethernet or PROFINET<br />

Safety requirements up to SIL 3 in accordance with<br />

IEC 61508/62061 or EN ISO 13849-1 up to PL e can be<br />

implemented with WinAC RTX F.<br />

Rugged operation<br />

- Operation without a hard disk, based on CompactFlash Card<br />

(CF Card) or Solid-State Drive and Windows Embedded<br />

Standard 2009<br />

- Fan-free operation<br />

- 128 KB of retentive data for WinAC RTX, also without<br />

uninterruptible power supply (UPS)<br />

Flexibility of a <strong>PC</strong>-based automation environment<br />

- Use of WinAC ODK with SIMATIC WinAC RTX or<br />

SIMATIC WinAC RTX F (read-only for fail-safe program<br />

section)<br />

- Connection option for USB devices, flat panel monitor or<br />

screen<br />

- <strong>PC</strong>Ie cards can be plugged in<br />

5/192<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Application<br />

The SIMATIC I<strong>PC</strong>227D bundles combine the advantages of the<br />

<strong>PC</strong>-based controller solutions with those of the classical<br />

PLC world: They offer the flexibility for integrating different tasks<br />

of an automation solution on one hardware platform. The<br />

diskless and fanless design of the I<strong>PC</strong>227D enable the solution<br />

to be used directly at the machine in a harsh environment. Using<br />

the PROFINET interface, the system can be integrated with<br />

minimal outlay in existing automation landscapes<br />

(SIMATIC world, <strong>Siemens</strong> drive systems).<br />

The SIMATIC I<strong>PC</strong>227D bundles are the preferred platform when<br />

the following criteria are to be fulfilled for the automation solution:<br />

Compact, "headless" operation<br />

For use with remote screen<br />

Integration of different tasks such as simple control,<br />

visualization, technology functions, or data processing in one<br />

hardware unit<br />

Use of application-specific hardware and software<br />

Use at the machine level<br />

Safety functions up to SIL 3 according to IEC 61508/62061 or<br />

according to EN ISO 13849-1 up to PL e with WinAC RTX F


■ Function<br />

Controlling:<br />

For the optimum control of processes with WinAC RTX, several<br />

processing levels are available:<br />

- Cyclic program processing<br />

- Interrupt processing<br />

- Time and date-controlled processing<br />

The controller can save up to 128 KB of retentive data on an<br />

optional, non-volatile memory without the need for an<br />

uninterruptible power supply (UPS).<br />

Total retentivity of all process values of SIMATIC WinAC RTX<br />

can be achieved with a generally available UPS<br />

Functional safety with WinAC RTX F:<br />

The functional safety is implemented by means of targeted<br />

safety functions in the software. Safety functions are implemented<br />

with the S7 Distributed Safety system, to place the plant<br />

in a safe state or to hold it in a safe state. The safety functions<br />

are mainly contained within the following components:<br />

in the safety-related user program (safety program) in<br />

WinLC RTX F<br />

in the fail-safe inputs and outputs (F-I/O)<br />

The F I/O ensures safety-related processing of the field information<br />

(emergency stop pushbutton, light barriers, motor precontrol).<br />

It features all hardware and software components<br />

required for reliable processing, according to the required safety<br />

class. The user only programs the user safety functions. The<br />

safety functions for the process can be implemented with a user<br />

safety function or a system-internal fault reaction function. If the<br />

F system is unable to perform the actual user safety function in<br />

the event of a fault, it performs instead the fault response<br />

function, e. g. the associated outputs are switched off and the<br />

F CPU enters the <strong>ST</strong>OP state.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Embedded Box <strong>PC</strong> bundles<br />

SIMATIC I<strong>PC</strong>227D bundles<br />

Visualization:<br />

SIMATIC WinCC RT Advanced can also be ordered as a preinstalled,<br />

ready-to-use option. WinCC RT Advanced offers<br />

powerful functions for visualizing the processes at the<br />

machine.<br />

A permanent message memory (PMB) is available on an<br />

additional partition.<br />

Open access to process values:<br />

The SIMATIC NET O<strong>PC</strong> server (versions with WinAC RTX)<br />

supplied with the SIMATIC I<strong>PC</strong>227D bundles provides open<br />

access to all process values. Any visualization systems or<br />

data processing systems can be linked to<br />

SIMATIC WinAC RTX via this interface.<br />

Communication:<br />

Programming of WinAC RTX with SIMATIC <strong>ST</strong>EP 7 and transfer<br />

of the WinCC RT Advanced project is performed via the<br />

integrated Industrial Ethernet interface. The communication<br />

package SIMATIC NET SOFTNET S7 Lean is installed for this<br />

purpose.<br />

Use of other software:<br />

The customer can install supporting software products.<br />

Windows Embedded Standard 2009 is designed the way<br />

typical add-on packages can be installed.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/193<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Embedded Box <strong>PC</strong> bundles<br />

SIMATIC I<strong>PC</strong>227D bundles<br />

■ Ordering data Order No. Order No.<br />

Configuration<br />

Configuration<br />

SIMATIC I<strong>PC</strong>227D On request<br />

Interfaces: 2 x Gbit LAN (RJ45),<br />

1 x serial COM1), 4 x USB<br />

Processors / memory expansion /<br />

retentivity<br />

Atom E660 (1.3 GHz),<br />

2 GByte RAM<br />

Atom E660 (1.3 GHz),<br />

2 GByte RAM, retentivity<br />

Atom E640 (1.0 GHz),<br />

1 GByte RAM<br />

Atom E640 (1.0 GHz),<br />

1 GByte RAM, retentivity<br />

Atom E620 (600 MHz),<br />

512 MByte RAM<br />

Atom E620 (600 MHz),<br />

512 MByte RAM, retentivity<br />

Drives<br />

Without drive, with CF slot<br />

250 GByte HDD SATA<br />

50 GByte Solid-State Drive SATA<br />

(SLC)<br />

2 GByte SIMATIC <strong>PC</strong><br />

CompactFlash<br />

4 GByte SIMATIC <strong>PC</strong><br />

CompactFlash<br />

8 GByte SIMATIC <strong>PC</strong><br />

CompactFlash<br />

COM interface<br />

COM1: RS232<br />

COM1: RS485<br />

COM1: CAN<br />

5/194<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC I<strong>PC</strong>227D On request<br />

Operating system<br />

Without operating system<br />

WES 2009 preinstalled<br />

(CF from 2 GB/SSD/HD)<br />

XP-Prof. MUI preinstalled on<br />

SSD / HD<br />

WES 7 preinstalled<br />

(CF from 4 GB/SSD/HD)<br />

Windows 7 MUI preinstalled on<br />

SSD / HD<br />

Software bundles<br />

Without RTX/HMI software<br />

RTX: WinAC RTX 2010<br />

RTX-F: WinAC RTX F 2010<br />

HMI: WinCC RT Advanced<br />

128 PT<br />

HMI: WinCC RT Advanced<br />

512 PT<br />

HMI: WinCC RT Advanced<br />

2048 PT<br />

HMI: WinCC RT Advanced<br />

4096 PT<br />

HMI/RTX: RT 128 PT<br />

HMI/RTX: RT 512 PT<br />

HMI/RTX: RT 2048 PT<br />

HMI/RTX: RT 4096 PT<br />

Device versions<br />

Basis<br />

<strong>PC</strong>Ie (1 slot)<br />

COM (COM2-4: RS232)<br />

IO (4 x dig. inputs/outputs each)<br />

Mounting accessories<br />

Standard mounting rail<br />

Wall mounting<br />

Portrait mounting<br />

Side mounting<br />

Note:<br />

Software Packages with SIMATIC WinCC flexible,<br />

SIMATIC WinCC and SIMATIC WinAC RTX (F) can be ordered<br />

together with the SIMATIC I<strong>PC</strong> with a price advantage.<br />

More information on "Embedded Bundles/Packages for industrial<br />

<strong>PC</strong>s".


■ More information<br />

Delivery<br />

Production and delivery of the devices will typically be<br />

completed within 13 business days after receipt of order. The<br />

hardware and mass memory with the complete, pre-installed,<br />

ready-to-use software are supplied fully assembled.<br />

Start-up<br />

Before the control or visualization application is complete,<br />

simply perform the following steps:<br />

Optional: Installation and setup of other software on the device<br />

Transfer of engineering projects from <strong>ST</strong>EP 7 or<br />

WinCC Advanced/ WinCC Professional<br />

Backup of the installed software and protection of the flashbased<br />

mass memory by switching on the Enhance Write filter<br />

Replacement devices<br />

For the in-store versions, repaired replacement devices are<br />

available extremely quickly ex stock. Preferred versions offer the<br />

following options:<br />

Only for I<strong>PC</strong>s with replaceable CompactFlash Card<br />

(supplied without mass storage)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Embedded Box <strong>PC</strong> bundles<br />

SIMATIC I<strong>PC</strong>227D bundles<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/195<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Embedded Box <strong>PC</strong> bundles<br />

SIMATIC I<strong>PC</strong>427C bundles<br />

■ Overview<br />

Get off to a quick start in automation solutions with embedded<br />

<strong>PC</strong> platforms.<br />

- SIMATIC WinAC RTX or SIMATIC WinAC RTX F preinstalled<br />

on SIMATIC I<strong>PC</strong>427C and ready for use<br />

- PROFINET, PROFIBUS and Industrial Ethernet prepared for<br />

use in a SIMATIC environment<br />

- Optional WinCC flexible for visualization tasks in parallel with<br />

SIMATIC WinAC RTX.<br />

- Configuration and programming with SIMATIC <strong>ST</strong>EP 7 via<br />

Industrial Ethernet, PROFINET or PROFIBUS<br />

Safety requirements up to SIL 3 in accordance with<br />

IEC 61508/62061 or EN ISO 13849-1 up to PL e can be<br />

implemented with WinAC RTX F.<br />

Rugged operation<br />

- Operation without a hard disk, based on CompactFlash Card<br />

(CF Card) or Solid State Drive and Windows Embedded<br />

Standard<br />

- Fan-free operation<br />

- 128 KB of retentive data for WinAC RTX, also without<br />

uninterruptible power supply (UPS)<br />

Flexibility of a <strong>PC</strong>-based automation environment<br />

- Free memory space on CF Card can be used for other<br />

<strong>PC</strong> applications<br />

- Use of WinAC ODK with SIMATIC WinAC RTX or<br />

SIMATIC WinAC RTX F (read-only for fail-safe program<br />

section)<br />

- Connection option for USB devices, flat panel monitor or<br />

screen<br />

- <strong>PC</strong>I 104 cards can be plugged in<br />

High-performance service concept<br />

- Replacement spare parts for preferred types available ex<br />

stock<br />

New hardware basis SIMATIC I<strong>PC</strong>427C<br />

Cost-effective versions with PROFINET, based on the<br />

standard Ethernet interface<br />

Current product versions of the pre-installed software:<br />

- SIMATIC WinAC RTX 2010 or SIMATIC WinAC RTX F 2010<br />

- SIMATIC WinCC flexible 2008 SP2<br />

- SIMATIC NET Edition 2008<br />

5/196<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Application<br />

The SIMATIC I<strong>PC</strong>427C bundles combine the advantages of the<br />

<strong>PC</strong>-based controller solutions with those of the classical<br />

PLC world: They offer the flexibility for integrating different tasks<br />

of an automation solution on one hardware platform. The<br />

diskless and fanless design of the I<strong>PC</strong>427C enable the solution<br />

to be used directly at the machine in a harsh environment. Using<br />

the PROFINET and PROFIBUS interfaces, the system can be<br />

integrated with minimal outlay in existing automation landscapes<br />

(SIMATIC world, <strong>Siemens</strong> drive systems).<br />

The SIMATIC I<strong>PC</strong>427C bundles are the preferred platform when<br />

the following criteria must be fulfilled for the automation solution:<br />

Ultra-compact, "headless" operation<br />

For use with remote screen<br />

Integration of different tasks such as control, visualization,<br />

technology functions or data processing in one hardware unit<br />

Use of application-specific hardware and software<br />

Use at machine level<br />

Safety functions up to SIL 3 according to IEC 61508/62061 or<br />

according to EN ISO 13849-1 up to PL e with WinAC RTX F


■ Function<br />

Controlling:<br />

For the optimum control of processes with WinAC RTX,<br />

several processing levels are available:<br />

- Cyclic program processing<br />

- Interrupt processing<br />

- Time and date-controlled processing<br />

The controller can save up to 128 KB of retentive data on an<br />

integrated, non-volatile memory, without the need for a UPS.<br />

The complete retentivity of all process values of<br />

SIMATIC WinAC RTX can be achieved with a generally<br />

available UPS.<br />

Functional safety with WinAC RTX F:<br />

The functional safety is implemented by means of targeted<br />

safety functions in the software. Safety functions are<br />

implemented with the S7 Distributed Safety system, to place<br />

the plant in a safe state or to hold it in a safe state. The safety<br />

functions are mainly contained within the following<br />

components:<br />

- In the safety-related user program (safety program)<br />

in WinLC RTX F<br />

- In the fail-safe inputs and outputs (F I/O).<br />

The F I/O ensures safety-related processing of the field<br />

information (emergency stop pushbutton, light barriers, motor<br />

pre-control) It features all the hardware and software<br />

components required for reliable processing, according to the<br />

required safety class. The user only programs the user safety<br />

functions. The safety functions for the process can be<br />

implemented with a user safety function or a system-internal<br />

fault reaction function. If the F system is unable to perform the<br />

actual user safety function in the event of a fault, it performs<br />

instead the fault response function, e.g. the associated<br />

outputs are switched off and the F CPU enters the <strong>ST</strong>OP state.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Embedded Box <strong>PC</strong> bundles<br />

SIMATIC I<strong>PC</strong>427C bundles<br />

Visualization:<br />

SIMATIC WinCC RT Advanced can also be ordered as a preinstalled,<br />

ready-to-use option.<br />

WinCC RT Advanced offers powerful functions for visualizing<br />

the processes at the machine.<br />

A permanent message memory (PMB) is available on an<br />

additional partition.<br />

Open access to process values:<br />

SIMATIC NET O<strong>PC</strong> server supplied with the SIMATIC I<strong>PC</strong>427C<br />

bundles (versions with WinAC RTX) provides open access to<br />

all process values. Any visualization systems or data<br />

processing systems can be linked to SIMATIC WinAC RTX via<br />

this interface.<br />

Communication:<br />

Programming of WinAC RTX with SIMATIC <strong>ST</strong>EP 7 and transfer<br />

of the WinCC flexible project are performed via the integrated<br />

Industrial Ethernet interface. The communication package<br />

SIMATIC NET SOFTNET S7 Lean is installed for this purpose.<br />

The S7 program can alternatively be downloaded<br />

to WinAC RTX via the PROFIBUS DP interface.<br />

Use of other software:<br />

The customer can install supporting software products.<br />

Windows XP Embedded is designed the way typical add-on<br />

packages can be installed.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/197<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Embedded Box <strong>PC</strong> bundles<br />

SIMATIC I<strong>PC</strong>427C bundles<br />

■ Ordering data Order No. Order No.<br />

SIMATIC I<strong>PC</strong>427C bundles<br />

Configuration (continued)<br />

Bundles with SIMATIC<br />

SIMATIC I<strong>PC</strong>427C with E 6ES7 675 - 1 D 7 7 0 - 7 770<br />

WinAC RTX 2010 (F) and<br />

pre-installed software<br />

WinCC flexible 2008<br />

Externally accessible mass<br />

(Windows Embedded Standard<br />

storage<br />

2009 operating system)<br />

SIMATIC I<strong>PC</strong>427C with E 6ES7 675 - 1 D 770 - 7 7 7 0<br />

Without (can only be ordered<br />

with internal mass storage)<br />

pre-installed software<br />

Processor<br />

1)<br />

A<br />

4 GB CompactFlash, Windows<br />

Embedded 2009 and software<br />

pre-installed 1)<br />

D<br />

Celeron M, 1.2 GHz,<br />

2x PROFINET (IE) 1)<br />

A<br />

Celeron M, 1.2 GHz,<br />

2x PROFINET (IE),<br />

1x PROFIBUS 1)<br />

B<br />

Core2 Solo, 1.2 GHz,<br />

2x PROFINET (IE) 1)<br />

E<br />

Core2 Solo, 1.2 GHz,<br />

2x PROFINET (IE),<br />

1x PROFIBUS 1)<br />

F<br />

Core2 Solo, 1.2 GHz,<br />

G<br />

1x PROFINET (IE), PROFINET<br />

(RT/IRT) 3 ports<br />

Core2 Duo, 1.2 GHz,<br />

2x PROFINET (IE) 1)<br />

J<br />

Core2 Duo, 1.2 GHz, 2x<br />

PROFINET (IE), 1x PROFIBUS 1)<br />

K<br />

Core2 Duo, 1.2 GHz, 1x<br />

L<br />

PROFINET (IE), PROFINET<br />

(RT/IRT) 3 ports<br />

Work memory<br />

1 GB RAM 2<br />

2 GB RAM 1) 3<br />

4 GB RAM 4<br />

Mass storage, internal<br />

Without (can only be ordered<br />

with externally accessible mass<br />

storage) 1)<br />

<strong>80</strong> GB HDD SATA, additionally<br />

with externally accessible CF<br />

32 GB Solid State Disk SATA,<br />

Windows Embedded 2009 and<br />

software pre-installed<br />

4 GB internal CompactFlash,<br />

Windows Embedded 2009 and<br />

software pre-installed 1)<br />

8 GB internal CompactFlash,<br />

Windows Embedded 2009 and<br />

software pre-installed 1)<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

1) Replacement hardware devices available in exchange<br />

5/198<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

0<br />

1<br />

2<br />

6<br />

7<br />

8 GB CompactFlash, Windows<br />

Embedded 2009 and software<br />

pre-installed 1)<br />

E<br />

Software configurations 1)<br />

WinAC RTX B<br />

WinCC flexible RT 128 PT C<br />

WinCC flexible RT 512 PT D<br />

WinCC flexible RT 2048 PT E<br />

WinCC flexible RT 4096 PT F<br />

WinAC RTX, WinCC flexible<br />

K<br />

RT 128 PT<br />

WinAC RTX, WinCC flexible<br />

L<br />

RT 512 PT<br />

WinAC RTX, WinCC flexible<br />

M<br />

RT 2048 PT<br />

WinAC RTX, WinCC flexible<br />

N<br />

RT 4096 PT<br />

WinAC RTX F P<br />

WinAC RTX F, WinCC flexible<br />

R<br />

RT 128 PT<br />

WinAC RTX F, WinCC flexible<br />

S<br />

RT 512 PT<br />

WinAC RTX F, WinCC flexible<br />

T<br />

RT 2048 PT<br />

WinAC RTX F, WinCC flexible<br />

U<br />

RT 4096 PT


("Built to order" with delivery time<br />

of max. 14 business days, for<br />

hardware only repairs are<br />

possible)<br />

I<strong>PC</strong>427C with WinCC RT,<br />

V7.0 SP2, incl. Update 1<br />

Fan-free, 4 x USB 2.0 (500 mA),<br />

1 x COM (RS 232), 24 V DC<br />

power supply with On/Off switch,<br />

2 x PROFINET (IE),<br />

Windows Embedded 2009 preinstalled,<br />

SIMATIC WinCC V7.0 SP2 incl.<br />

Update 1 Runtime pre-installed<br />

6ES7 675-1D..0-.B.0<br />

Client configurations<br />

Processor Celeron M 1.2 GHz,<br />

1 GB SDRAM-DDR3, 4 GB CF<br />

Card, runtime license 128 PT<br />

Client and single-user station<br />

configurations<br />

E 6ES7 675-1DA20-6AX0<br />

Processor Core2 Solo 1.2 GHz,<br />

2 GB SDRAM-DDR3, 8 GB CF<br />

Card, runtime license 128 PT<br />

E 6ES7 675-1DE30-7AX0<br />

Processor Core2 Solo 1.2 GHz,<br />

PROFIBUS DP, 2 GB SDRAM-<br />

DDR3, 8 GB CF Card, runtime<br />

license 128 PT<br />

E 6ES7 675-1DF30-7AX0<br />

Single-user station<br />

6ES7 675-1DK40-.A.0<br />

configurations<br />

Core2 Duo processor 1.2 GHz,<br />

PROFIBUS DP,<br />

4 GB SDRAM-DDR3<br />

8 GB CF Card 6ES7 675-1DK40-7A.0<br />

32 GB SSD 6ES7 675-1DK40-2A.0<br />

Runtime license 128 PT 6ES7 675-1DK40-.AX0<br />

Runtime license 2048 PT 6ES7 675-1DK40-.AW0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Embedded Box <strong>PC</strong> bundles<br />

SIMATIC I<strong>PC</strong>427C bundles<br />

■ Ordering data Order No. Order No.<br />

Delivery versions (from stock)<br />

Accessories<br />

Replacement hardware units<br />

CP 5603 Microbox Package A 6GK1 560-3AU00<br />

available in exchange<br />

Package for using the<br />

SIMATIC I<strong>PC</strong>427C bundle with<br />

PROFIBUS CP 5603 in Microbox<br />

WinAC RTX 2010<br />

<strong>PC</strong>s; comprising a CP 5603<br />

Core2 Solo processor, 1.2 GHz, E<br />

2x PROFINET (IE), 1x PROFIBUS,<br />

6ES7 675-1DF30-0DB0<br />

module and a Microbox<br />

expansion rack<br />

2 GB RAM, 4 GB CompactFlash<br />

CP 1604 Microbox Package 6GK1 160-4AU00<br />

Core2 Solo processor, 1.2 GHz, E 6ES7 675-1DK30-0DB0<br />

Package for using the<br />

2x PROFINET (IE), 1x PROFIBUS,<br />

PROFINET CP 1604 in Microbox<br />

2 GB RAM, 4 GB CompactFlash<br />

<strong>PC</strong>s; comprising CP 1604,<br />

Core2 Solo processor, 1.2 GHz, E<br />

2x PROFINET (IE), 1x PROFIBUS,<br />

2 GB RAM, 8 GB CompactFlash<br />

6ES7 675-1DK30-0EP0<br />

connection board, power supply<br />

and expansion rack for Microbox<br />

<strong>PC</strong>; implemented with Development<br />

Kit DK-16xx PN IO;<br />

SIMATIC I<strong>PC</strong>427C bundle with<br />

NCM P<br />

WinAC RTX 2010 and<br />

WinCC flexible 2008 512 PT<br />

Expansion kit <strong>PC</strong>/104 6AG4 070-0BA00-0XA0<br />

Core2 Solo processor, 1.2 GHz, E<br />

2x PROFINET (IE), 1x PROFIBUS,<br />

6ES7 675-1DK30-0DL0<br />

Expansion rack incl. mounting<br />

hardware; 6 items<br />

2 GB RAM, 4 GB CompactFlash<br />

CompactFlash Cards<br />

Bundles with WinCC<br />

4GB A 6ES7 648-2BF02-0XG0<br />

8 GB<br />

SIMATIC <strong>PC</strong> keyboard<br />

A 6ES7 648-2BF02-0XH0<br />

German/international,<br />

USB connection<br />

6ES7 648-0CB00-0YA0<br />

German/international,<br />

USB connection, with 4-way<br />

USB HUB<br />

A 6ES7 648-0CD00-0YA0<br />

SIMATIC <strong>PC</strong> USB mouse A 6ES7 790-0AA01-0XA0<br />

Optical, 3 buttons, with<br />

PS/2 adapter<br />

SIMATIC I<strong>PC</strong> USB FlashDrive<br />

8 GB (SLC), USB 2.0, incl.<br />

SIMATIC I<strong>PC</strong> BIOS manager,<br />

bootable, metal housing<br />

A 6ES7 648-0DC50-0AA0<br />

SIMATIC I<strong>PC</strong> Service<br />

USB FlashDrive<br />

8 GB (SLC), USB 2.0, incl.<br />

SIMATIC I<strong>PC</strong> Image & Partition<br />

Creator and SIMATIC I<strong>PC</strong> BIOS<br />

manager (pre-installed),<br />

bootable, metal enclosure<br />

B 6AV7 672-8JD01-0AA0<br />

Portrait assembly kit<br />

Interfaces to the front<br />

A 6ES7 648-1AA20-0YB0<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/199<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Embedded Box <strong>PC</strong> bundles<br />

SIMATIC I<strong>PC</strong>427C bundles<br />

■ More information<br />

Delivery<br />

Production and delivery of the devices will typically be<br />

completed within 13 business days after receipt of order. The<br />

hardware and mass memory with the complete, pre-installed,<br />

ready-to-use software are supplied fully assembled.<br />

Commissioning<br />

Before the control or visualization application is complete,<br />

simply perform the following steps:<br />

Optional: Install and setup additional hardware on the device<br />

(e. g. an additional SIMATIC CP 5603 PROFIBUS interface)<br />

Optional: Installation and setup of other software on the device<br />

Transfer of the engineering projects from <strong>ST</strong>EP 7 or<br />

WinCC flexible<br />

Transfer of the supplied license keys for SIMATIC software<br />

Backup of the installed software and protection of the flashbased<br />

mass memory by switching on the Enhance Write filter<br />

5/200<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Replacement devices<br />

For the preferred versions, repaired replacement devices are<br />

available extremely quickly ex stock. Preferred versions offer the<br />

following options:<br />

All processor versions with PROFINET(IE) or PROFIBUS<br />

option<br />

2 GB RAM<br />

Exclusively for replaceable CompactFlash memory (supplied<br />

without mass memory)<br />

All software configurations


■ Overview<br />

SIMATIC HMI I<strong>PC</strong>277D for implementing simple visualization<br />

and control tasks<br />

High degree of flexibility when selecting rugged widescreen<br />

fronts from 7" to 12" for more freely configurable display area<br />

High resolution, large viewing angle and up to 100%<br />

dimmable backlighting for brilliant display with optimized<br />

power consumption<br />

Absolutely maintenance-free due to the use of CompactFlash<br />

and SSD as mass storage and fanless operation up to<br />

50 °C ambient temperature<br />

Maximum industrial functionality due to non-volatile retentive<br />

memory for battery-free operation<br />

Ready-to-run embedded bundles with visualization or/and<br />

control software<br />

The following front installation versions are available:<br />

7" Touch<br />

9" Touch<br />

12" Touch<br />

All fronts in widescreen design<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

<strong>PC</strong>-based Automation<br />

Embedded Panel <strong>PC</strong> bundles<br />

SIMATIC HMI I<strong>PC</strong>277D bundles<br />

SIMATIC HMI I<strong>PC</strong>277D<br />

Rugged, industry-standard 7" / 9" / 12" widescreen displays<br />

(Touch)<br />

- High resolution, 16 million colors, large viewing angle,<br />

dimmable from 0 to 100% (this also optimizes the power<br />

consumption)<br />

- Integrated front concept (Panel <strong>PC</strong>, Comfort Panels)<br />

- Fanless at up to 50 °C ambient temperature<br />

High-performance data processing at low power<br />

consumption<br />

Intel Atom technology of the Power-Optimized family E6xx<br />

Wake-on-LAN for remote-controlled switching between standby<br />

and active state<br />

Support of Sleep States/SpeedStep -> dynamic power<br />

adaptation depending on the required computing<br />

performance<br />

Intel VT-x technology for virtualization<br />

High degree of industrial functionality and flexibility for<br />

implementing the embedded solution<br />

Flexible memory concepts: CompactFlash or Solid-State Drive<br />

2 Gbit Ethernet (teaming-capable); PROFINET with<br />

RT functionality (via Standard Ethernet)<br />

3 high-speed USB 2.0 ports<br />

1 RS232<br />

Ready-to-run embedded bundles with WinAC RTX2010<br />

and/or WinCC RT Advanced (optional)<br />

512 KB retentive memory (MRAM), of which 128 KB can be<br />

written to within the buffer time (optional)<br />

High system availability in order to reduce the risk of<br />

potential failures and maintenance costs<br />

Maintenance-free since there are no rotating parts (fans, HDD)<br />

Battery-free operation even if retentive memory option is<br />

selected (with time-of-day synchronization via network)<br />

Comprehensive self-diagnostics by means of pre-installed<br />

local diagnostics software SIMATIC I<strong>PC</strong> DiagBase<br />

High investment security in order to reduce engineering<br />

costs<br />

Long-term availability: Service and support period of<br />

8 - 10 years after market launch<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/201<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Embedded Panel <strong>PC</strong> bundles<br />

SIMATIC HMI I<strong>PC</strong>277D bundles<br />

■ Application<br />

The SIMATIC HMI I<strong>PC</strong>277D is a particularly compact and<br />

energy-efficient Nanopanel <strong>PC</strong> with integrated touch displays<br />

with 7-inch screen diagonal or larger. The heart of the<br />

SIMATIC HMI I<strong>PC</strong>277D are high-performance Intel Atom<br />

processors of the latest generation. The Nanopanel <strong>PC</strong>s are<br />

designed for maintenance-free 24-hour continuous operation<br />

and even meet high temperature, vibration, shock and EMC<br />

requirements:<br />

Simple visualization and control tasks in areas such as<br />

mechanical engineering, plant construction, building<br />

automation, transportation systems, or power transmission.<br />

Acquisition, further processing, and visualization of data<br />

All machine-level applications created in C/C++ or with<br />

WinAC/WinCC RT advanced that require rugged, compact<br />

I<strong>PC</strong>s<br />

Additional new applications such as shipbuilding, storage<br />

and logistics<br />

The application spectrum ranges from automation computers<br />

fully integrated in TIA with WinAC, for example, to C/C++-based<br />

automation solutions with customer-specific operating systems.<br />

For software products that require Windows XP Professional, we<br />

offer Windows XP Professional multi language pre-installed on a<br />

Solid-State Drive.<br />

The SIMATIC HMI I<strong>PC</strong>277D can be ordered in conjunction with<br />

WinCC RT Advanced and/or with WinAC RTX 2010 at an<br />

attractive price as ready-to-use bundle.<br />

■ Function<br />

Visualization<br />

SIMATIC WinCC RT Advanced can also be ordered as an<br />

option, preinstalled and ready-to-use. WinCC RT Advanced<br />

offers Powerful methods of visualizing the processes in the<br />

machine.<br />

A permanent message buffer (PMB) is available on an<br />

additional partition.<br />

Controlling<br />

Cyclic program processing<br />

Interrupt processing<br />

Time and date-controlled processing<br />

The controller can save up to 128 KB of retentive data on one<br />

integrated, non-volatile memory without the need for an<br />

uninterruptible power supply (UPS).<br />

Total retentivity of all process values of SIMATIC WinAC RTX<br />

can be achieved with a generally available UPS.<br />

5/202<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Functional safety with WinAC RTX F<br />

The functional safety is implemented by means of targeted<br />

safety functions in the software. Safety functions are<br />

implemented with the S7 Distributed Safety system, to place<br />

the plant in a safe state or to hold it in a safe state. The safety<br />

functions are mainly contained within the following<br />

components:<br />

- In the safety-related user program (safety program) in<br />

WinLC RTX F<br />

- In the fail-safe inputs and outputs (F I/O).<br />

The F I/O ensures safety-related processing of the field<br />

information (emergency stop pushbutton, light barriers, motor<br />

pre-control). It features all the hardware and software<br />

components required for reliable processing, according to the<br />

required safety class. The user only programs the user safety<br />

functions. The safety functions for the process can be<br />

implemented with a user safety function or a system-internal<br />

fault reaction function. If the F system is unable to perform the<br />

actual user safety function in the event of a fault, it performs<br />

instead the fault response function, e.g. the associated<br />

outputs are switched off and the F CPU enters the <strong>ST</strong>OP state.<br />

Open access to process values<br />

SIMATIC NET O<strong>PC</strong> server supplied with the SIMATIC I<strong>PC</strong>427C<br />

bundles (versions with WinAC RTX) provides open access to<br />

all process values. Any visualization systems or data<br />

processing systems can be linked to SIMATIC WinAC RTX via<br />

this interface.<br />

Communication:<br />

Programming of WinAC RTX with SIMATIC <strong>ST</strong>EP 7 and transfer<br />

of the WinCC RT V11 Advanced project is performed via the<br />

integrated Industrial Ethernet interface. The communication<br />

package SIMATIC NET SOFTNET S7 Lean is installed for this<br />

purpose.<br />

Use of other software:<br />

The customer can install supporting software products.<br />

Windows XP Embedded is designed so that typical add-on<br />

packages can be installed.


Interfaces: 2 x Gbit LAN (RJ45),<br />

1 x serial (COM1), 3 x USB<br />

Operating unit<br />

Touch 7" TFT<br />

Touch 9" TFT<br />

Touch 12" TFT<br />

Touch 15" TFT,<br />

front USB interface<br />

Touch 19" TFT,<br />

front USB interface<br />

Processors / memory expansion /<br />

retentivity<br />

Atom E660 (1.3 GHz),<br />

2 GByte RAM<br />

Atom E660 (1.3 GHz),<br />

2 GByte RAM, retentivity<br />

Atom E640 (1.0 GHz),<br />

1 GByte RAM<br />

Atom E640 (1.0 GHz),<br />

1 GByte RAM, retentivity<br />

Drives<br />

Without drive, with CF slot<br />

2 GByte SIMATIC <strong>PC</strong><br />

CompactFlash<br />

4 GByte SIMATIC <strong>PC</strong><br />

CompactFlash<br />

8 GByte SIMATIC <strong>PC</strong><br />

CompactFlash<br />

50 GByte Solid-State Drive SATA<br />

(SLC)<br />

Operating system<br />

Without operating system<br />

WES 2009 preinstalled<br />

(CF from 2 GByte/SSD)<br />

XP-Prof. MUI preinstalled on<br />

SSD<br />

WES 7 vorinstalliert<br />

(CF from 4 GByte /SSD)<br />

Windows 7 MUI preinstalled on<br />

SSD<br />

Software bundles<br />

Without RTX/HMI software<br />

RTX: WinAC RTX 2010<br />

RTX-F: WinAC RTX F 2010<br />

HMI: WinCC RT Advanced<br />

128 PT<br />

HMI: WinCC RT Advanced<br />

512 PT<br />

HMI: WinCC RT Advanced<br />

2048 PT<br />

HMI: WinCC RT Advanced<br />

4096 PT<br />

HMI/RTX: RT 128 PT<br />

HMI/RTX: RT 512 PT<br />

HMI/RTX: RT 2048 PT<br />

HMI/RTX: RT 4096 PT<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Note:<br />

<strong>PC</strong>-based Automation<br />

Embedded Panel <strong>PC</strong> bundles<br />

SIMATIC HMI I<strong>PC</strong>277D bundles<br />

■ Ordering data Order No. Order No.<br />

Configuration<br />

Accessories<br />

SIMATIC HMI I<strong>PC</strong>277D On request<br />

Touch pen<br />

Captive pen for operation of the<br />

touch devices, mounting of the<br />

support on the control cabinet or<br />

direct on the PRO unit<br />

A 6AV7 672-1JB00-0AA0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

Software Packages with SIMATIC WinCC flexible,<br />

SIMATIC WinCC and SIMATIC WinAC RTX (F) can be ordered<br />

together with the SIMATIC I<strong>PC</strong> with a price advantage.<br />

More information under "Embedded Bundles/Packages for<br />

industrial <strong>PC</strong>s".<br />

Please be sure to note:<br />

The HMI I<strong>PC</strong>277D with bundle SW is delivered as standard with<br />

an inserted CF card. The licenses are located on the supplied<br />

USB flash drive.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/203<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Embedded Panel <strong>PC</strong> bundles<br />

SIMATIC HMI I<strong>PC</strong>277D bundles<br />

■ More information<br />

Delivery<br />

Production and delivery of the devices will typically be<br />

completed within 13 business days after receipt of order. The<br />

hardware and mass memory with the complete, pre-installed,<br />

ready-to-use software are supplied fully assembled.<br />

Commissioning<br />

Before the control or visualization application is complete,<br />

simply perform the following steps:<br />

Optional: Install and setup additional hardware on the device<br />

Transfer of the engineering projects from <strong>ST</strong>EP 7 or<br />

WinCC Advanced/WinCC Professional<br />

Transfer of the supplied license keys for SIMATIC software<br />

Backup of the installed software and protection of the<br />

flashbased mass memory by switching on the Enhance Write<br />

filter<br />

Replacement devices<br />

For the preferred versions, repaired replacement devices are<br />

available extremely quickly ex stock. Preferred versions offer the<br />

following options:<br />

Exclusively for I<strong>PC</strong>s with replaceable CompactFlash memory<br />

(supplied without mass memory)<br />

5/204<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Overview<br />

Embedded <strong>PC</strong> platform with extremely high industrial compatibility<br />

for demanding tasks in the field of <strong>PC</strong>-based automation<br />

Maintenance-free (no rotating components such as fan and<br />

hard disk)<br />

Rugged construction: The <strong>PC</strong> is resistant to even the harshest<br />

mechanical stress and is extremely reliable in operation<br />

Battery-backed retentive memory onboard<br />

Compact design (only 61-69 mm installation depth for 12"-19")<br />

High investment protection<br />

Fast integration capability<br />

The following versions are available:<br />

Built-in versions<br />

- 12" and 15" TFT Touch<br />

- 12" and 15" TFT Key<br />

- 19" Touch<br />

Support arm versions<br />

- PRO 15" and 19" Touch<br />

Fully-enclosed device to IP65 degree of protection for<br />

mounting on a support arm/stand.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

<strong>PC</strong>-based Automation<br />

Embedded Panel <strong>PC</strong> bundles<br />

SIMATIC HMI I<strong>PC</strong>477C bundles<br />

Excellent industrial compatibility due to rugged construction,<br />

even when subjected to extreme vibration and shock<br />

High degree of investment protection thanks to assured<br />

availability of spare parts (for a period of 5 years following the<br />

end of active marketing)<br />

High degree of continuity of components for long-lasting<br />

machine concepts without new engineering overhead<br />

Savings in time and costs due to service-friendly device<br />

design:<br />

- USB 2.0 ports on the front and rear for simple and fast<br />

connection of additional hardware components<br />

High degree of industrial functionality thanks to integrated<br />

PROFIBUS DP/MPI and PROFINET (IE, RT/IRT) interfaces<br />

Maintenance-free due to lack of rotating components (fan and<br />

hard disk)<br />

Minimization of downtimes thanks to high system availability<br />

- Efficient self-diagnostics (DiagBase and SIMATIC I<strong>PC</strong><br />

DiagMonitor)<br />

- High reliability and security of an embedded platform<br />

An integrated component of Totally Integrated Automation<br />

(TIA):<br />

- Increase in productivity, minimization of engineering<br />

overhead, reduction in lifecycle costs<br />

Supply of turnkey complete solutions (software already<br />

installed and preconfigured) for visualization and automation<br />

in combination with WinCC flexible and WinAC RTX.<br />

■ Application<br />

The SIMATIC HMI I<strong>PC</strong>477C is designed for use direct at the<br />

machine, where the focus is on the combination of ruggedness<br />

and maximum reliability (safety of an embedded platform), and<br />

where the openness of a <strong>PC</strong> is also required (e. g. module<br />

expansion and connection of I/O devices such as printers,<br />

keyboards, etc.).<br />

Due to the minimal mounting depth, it can also be used in<br />

confined spaces.<br />

The <strong>PC</strong> is used both in manufacturing automation and process<br />

automation, installed in control cabinets and consoles,<br />

19" cabinets/racks, and as PRO version direct on swivel arms<br />

(booms).<br />

A SIMATIC Panel <strong>PC</strong> is the ideal platform for <strong>PC</strong>-based<br />

automation:<br />

<strong>PC</strong>-based visualization, on-site at the machine with<br />

SIMATIC WinCC flexible<br />

<strong>PC</strong>-based Control with SIMATIC WinAC RTX<br />

SIMATIC WinCC Web client for Web-based solutions with<br />

WinCC/Web Navigator<br />

SIMATIC WinCC Standard Client and single-user solution<br />

<strong>Siemens</strong> offers the complete modular system of perfectly coordinated<br />

automation components.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/205<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Embedded Panel <strong>PC</strong> bundles<br />

SIMATIC HMI I<strong>PC</strong>477C bundles<br />

■ Design<br />

The HMI I<strong>PC</strong>477C is a compact device comprising an operator<br />

control unit with integrated computer unit.<br />

Standard components of the computer unit:<br />

Rugged metal enclosure, resistant to vibration and shock, with<br />

high electromagnetic compatibility<br />

Processors:<br />

- Intel Celeron M 1.2 GHz, Intel Core2 Solo 1.2 GHz or<br />

Intel Core2 Duo 1.2 GHz<br />

Main memory basic configuration:<br />

- 1.2 or 4 GB (DDR3)<br />

- Battery-backed retentive memory 2 MB<br />

CompactFlash Drive (internal) with pre-installed Windows XP<br />

embedded operating system (Image) and optional software or<br />

Solid State Disk (SSD) with Windows XP embedded or<br />

Windows XP Professional (MUI)<br />

Graphics onboard (VGA analog, 12<strong>80</strong> x 1024)<br />

Interfaces:<br />

- 2 x PROFINET (IE) onboard (10/100/1000 Mbit/s)<br />

- Optional PROFIBUS DP/MPI onboard,<br />

CP 5611-compatible, isolated<br />

- Optional PROFINET (RT/IRT) onboard, CP 1616-compatible,<br />

3 ports<br />

- 5 x USB 2.0 port, 500 mA (1 x on front)<br />

- 1 x COM1 (RS232)<br />

- 1 x DVI-I (for connecting a second display unit)<br />

Free slots for expansions:<br />

- 1 x CompactFlash slot (externally accessible)<br />

Power supply: 24 V DC<br />

Components of the operator control unit:<br />

The operator control units are available in the following versions:<br />

12" Key<br />

12" TFT color display, <strong>80</strong>0 x 600 pixels (SVGA)<br />

Membrane keyboard with international <strong>PC</strong> character set and<br />

36 additional function keys, as well as integrated mouse<br />

USB interface<br />

12" Touch<br />

12" TFT color display, <strong>80</strong>0 x 600 pixels (SVGA)<br />

Resistive analog touch screen<br />

USB interface<br />

15" Key<br />

15" TFT color display, 1024 x 768 pixels (XGA)<br />

Membrane keyboard with international <strong>PC</strong> character set and<br />

36 additional function keys, as well as integrated mouse<br />

USB interface<br />

15" Touch<br />

15" TFT color display, 1024 x 768 pixels (XGA)<br />

Resistive analog touch screen<br />

USB interface<br />

5/206<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

19" Touch<br />

19" TFT color display, 12<strong>80</strong> x 1024 (SXGA)<br />

Resistive analog touch screen<br />

USB interface<br />

PRO 15" Touch<br />

Fully enclosed device with degree of protection IP65 for<br />

mounting on a support arm/stand<br />

15" TFT color display, 1024 x 768 pixels (XGA)<br />

Resistive analog touch screen<br />

PRO 19" Touch<br />

Fully enclosed device with degree of protection IP65 for<br />

mounting on a support arm/stand<br />

19" TFT color display, 12<strong>80</strong> x 1024 pixels (SXGA)<br />

Resistive analog touch screen<br />

The built-in devices are equipped with an USB 2.0 interface at<br />

the front for connecting external I/O devices such as a mouse or<br />

keyboard and fulfill the requirements of degree of protection<br />

IP65 and NEMA 4.<br />

Expansion components (accessories)<br />

SIMATIC I<strong>PC</strong> DiagMonitor<br />

<strong>PC</strong> diagnostics/alarm software for early detection and<br />

diagnosis of <strong>PC</strong> problems<br />

Comprehensive monitoring of temperature, watchdog<br />

Operating hours counter for preventive maintenance<br />

Integrated log functions, comprehensive text messages,<br />

online help (English/German)<br />

Network-wide monitoring via SNMP and O<strong>PC</strong> interface<br />

possible<br />

SIMATIC I<strong>PC</strong> Image & Partition Creator<br />

Software tool for preventive data back-up of the contents of<br />

bulk storage (CF cards, hard disks)<br />

High-speed restoring of system and data partitions with bit<br />

accuracy; user software and special installations are also<br />

backed up<br />

Software tool for adaptation of mass storage partitioning.<br />

3.5" USB disk drive<br />

The USB disk drive is provided for fast exchange of user data<br />

(e. g. recipes) or files. The drive must not be used as a cyclic<br />

archiving drive. The front-panel installation and degree of<br />

protection IP54 permit data exchange from the front without<br />

opening the control cabinet door.<br />

The device is connected via the USB interface of the Panel <strong>PC</strong>.<br />

The power is also supplied over the USB interface. A USB cable<br />

of 1 m length is included in the scope of supply. The disk drive<br />

corresponds to the USB 1.1 standard. 3.5" high density disks<br />

can be used (1.44 MB).<br />

Operation of the USB disk drive on SIMATIC Panel <strong>PC</strong>s:<br />

Windows XP: possible without separate driver<br />

The driver is included in the scope of supply of the operating<br />

system


■ Design (continued)<br />

SIMATIC I<strong>PC</strong> USB FlashDrive<br />

Mobile memory medium for SIMATIC <strong>PC</strong>/PG<br />

Fast data transfer (USB 2.0) and high memory capacity<br />

Ultra-compact and rugged<br />

SIMATIC I<strong>PC</strong> Service USB FlashDrive<br />

Mobile memory medium for backing up/restoring mass<br />

memories<br />

Pre-installed Image & Partition Creator V3.0 and BIOS<br />

manager<br />

Ultra-compact and rugged<br />

Industrial USB Hub 4<br />

Industry-standard USB 2.0 hub, front IP65<br />

Installation in control cabinet door or on DIN rail<br />

Inspection window and LEDs for each of the four interfaces<br />

Note:<br />

You can find more information under "Expansion components".<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Embedded Panel <strong>PC</strong> bundles<br />

SIMATIC HMI I<strong>PC</strong>477C bundles<br />

■ Function<br />

DiagBase: Integrated, parameterizable monitoring functions<br />

(program execution/watchdog, internal enclosure<br />

temperature, DIAG bit for CF cards similar to S.M.A.R.T for<br />

hard disks)<br />

Expanded diagnostics/messages via Ethernet, e-mail, text<br />

message and for direct transfer to SIMATIC software via O<strong>PC</strong><br />

(optionally via SIMATIC I<strong>PC</strong> DiagMonitor)<br />

■ Integration<br />

Integrated interfaces:<br />

Ethernet<br />

The integrated PROFINET interfaces (10/100/1000 Mbit/s) can<br />

be used for IT communication and for exchanging data with<br />

programmable controllers such as SIMATIC S7 (with the<br />

"SOFTNET S7" software packages).<br />

Available options: PROFINET (iRT) with 3 ports instead of an<br />

PROFINET (IE).<br />

PROFIBUS onboard (option)<br />

The floating PROFIBUS interface (12 Mbit/s) can be used for<br />

connecting distributed field devices or for coupling to<br />

SIMATIC S7 (with software packages "SOFTNET for<br />

PROFIBUS").<br />

Other interfaces<br />

For connecting additional I/O devices, 5 USB (Universal Serial<br />

Bus) interfaces and one serial interface are available.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/207<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Embedded Panel <strong>PC</strong> bundles<br />

SIMATIC HMI I<strong>PC</strong>477C bundles<br />

■ Technical specifications<br />

6AV7 884.. 6AV7 883..PRO<br />

General features<br />

Processors Intel Celeron M 1.2 GHz, Intel Core2 Solo 1.2 GHz or Intel Celeron M 1.2 GHz, Intel Core2 Solo 1.2 GHz or<br />

Core2 Duo 1.2 GHz<br />

Core2 Duo 1.2 GHz<br />

Memory type DDR3-RAM DDR3-RAM<br />

Main memory 1 GB, 2 GB or 4 GB 1 GB, 2 GB or 4 GB<br />

Free slots 1 x CF card slot (externally accessible) 1 x CF card slot (externally accessible)<br />

Operating system Windows Embedded Standard 2009 (ENG/GER) or Windows Embedded Standard 2009 (ENG/GER) or<br />

Windows XP Professional multi language<br />

Windows XP Professional multi language<br />

Additional OS information Language: ENG/GER Language: ENG/GER<br />

SIMATIC Software Optionally with preinstalled bundle software SIMATIC Optionally with preinstalled bundle software SIMATIC<br />

WinCC flexible and/or WinAC RTX 2 SIMATIC WinAC WinCC flexible 2 S and/or WinAC RTX SIMATIC<br />

RTX F SIMATIC WinCC as web client or single-user WinAC RTX F SIMATIC WinCC as web client or<br />

Drives<br />

station<br />

single-user station<br />

Disk drive Optionally via external USB floppy disk drive Optionally via external USB floppy disk drive<br />

Optical drives Possible as external drive via USB Possible as external drive via USB<br />

Hard drive/mass storage CompactFlash drive with 2, 4 or 8 GB<br />

CompactFlash drive with 2, 4 or 8 GB<br />

Interfaces<br />

and/or SSD (Solid State Drive) with 32 GB<br />

and/or SSD (Solid State Drive) with 32 GB<br />

Graphic interface DVI-I for additional display unit: Color depth 32 bits DVI-I for additional display unit: Color depth 32 bits<br />

Connection for keyboard/mouse USB / USB USB / USB<br />

Serial interface COM1: 1 x V.24 (RS232) COM1: 1 x V.24 (RS232)<br />

PROFIBUS/MPI Optionally onboard, isolated, max. 12 Mbit/s, no Optionally onboard, isolated, max. 12 Mbit/s, no<br />

plug-in card required, CP 5611-compatible, not plug-in card required, CP 5611-compatible, not<br />

upgradeable<br />

upgradeable<br />

PROFINET (RT/IRT) Optional: 3 x RJ45, CP 1616-compatible; not Optional: 3 x RJ45, CP 1616-compatible; not<br />

upgradeable<br />

upgradeable<br />

USB 1 x on front, 4 x on rear, USB 2.0 (500 mA) 1 x on front, 4 x on rear, USB 2.0 (500 mA)<br />

PROFINET (IE), Ethernet onboard, 2 x 10/100/1000 Mbit (RJ45 with/without onboard, 2 x 10/100/1000 Mbit (RJ45 with/without<br />

PROFIBUS), 1 x 10/100/1000 Mbit (RJ45 with PROFIBUS), 1 x 10/100/1000 Mbit (RJ45 with<br />

PROFINET), no plug-in card required<br />

PROFINET), no plug-in card required<br />

Multimedia<br />

Supply voltage<br />

No No<br />

Supply voltage<br />

Monitoring functions<br />

24 V DC 24 V DC<br />

Temperature Yes Yes<br />

Watchdog Yes Yes<br />

Diagbit (similar to S.M.A.R.T.) Yes (for CF cards and SSD) Yes (for CF cards and SSD)<br />

Status LEDs Yes (on rear) Yes<br />

Front side according to EN 60529<br />

Ambient conditions<br />

IP65 (on the front) according to EN 60529 and<br />

NEMA4<br />

IP65 all around according to EN 60529 and NEMA4<br />

Vibration load during operation Tested in accordance with IEC 60068-2-6:<br />

Tested in accordance with IEC 60068-2-6:<br />

10 - 58 Hz: 0.075 mm, 58 to 200 Hz: 9.8 m/s² (1 g) 10 - 58 Hz: 0.075 mm, 58 to 200 Hz: 9.8 m/s² (1 g)<br />

Shock load during operation Tested in accordance with IEC 60068-2-7:<br />

Tested in accordance with IEC 60068-2-7:<br />

50 m/s² (5 g), 30 ms, 100 shocks<br />

50 m/s² (5 g), 30 ms, 100 shocks<br />

Relative humidity Tested in accordance with IEC 60068-78,<br />

Tested in accordance with IEC 60068-78,<br />

IEC 60068-2-30: 5% to <strong>80</strong>% at 25 °C (no conden- IEC 60068-2-30: 5% to <strong>80</strong>% at 25 °C (no condensation)sation)<br />

Maximum permissible installation<br />

angle +/-<br />

30° over vertical 45° over vertical<br />

Ambient temperature during operation<br />

Certifications & standards<br />

0 °C … +50 °C in maximum configuration; no fan 15“: 0 °C … +45 °C in maximum configuration; no<br />

fan 19“: 0 °C … +40 °C in maximum configuration;<br />

no fan<br />

Approvals CE, cULus(508), Marine CE, cULus(508)<br />

EMC CE, 55022A, EN 61000-6-4, EN 61000-6-2 CE, 55022A, EN 61000-6-4, EN 61000-6-2<br />

5/208<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Technical specifications (continued)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Embedded Panel <strong>PC</strong> bundles<br />

6AV7 884-0 6AV7 884-1 6AV7 884-2 6AV7 884-3 6AV7 884-5 6AV7 883-6<br />

(PRO)<br />

SIMATIC HMI I<strong>PC</strong>477C bundles<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6AV7 883-7<br />

(PRO)<br />

Front panel<br />

Display<br />

12" TFT Touch 12" TFT Key 15" TFT Touch 15" TFT Key 19" TFT Touch 15" TFT Touch 19" TFT Touch<br />

Resolution<br />

(W x H in pixels)<br />

<strong>80</strong>0 x 600 <strong>80</strong>0 x 600 1024 x 768 1024 x 768 12<strong>80</strong> x 1024 1024 x 768 12<strong>80</strong> x 1024<br />

MTBF of<br />

50000 h at 24 h 50000 h at 24 h 50000 h at 24 h 50000 h at 24 h 50000 h at 24 h 50000 h at 24 h 50000 h at 24 h<br />

backlighting continuous continuous continuous continuous continuous continuous continuous<br />

(at 25 °C) operation, operation, operation, operation, operation, operation, operation,<br />

temperaturetemperaturetemperaturetemperaturetemperaturetemperaturetemperature- Type of<br />

operation<br />

dependentdependentdependentdependentdependentdependentdependent Function keys No 36 No 36 No No No<br />

Alphanumeric<br />

keyboard<br />

No Yes No Yes No No No<br />

Touch screen<br />

(analog/resistive)<br />

Yes No Yes No Yes Yes Yes<br />

Mouse on front<br />

Design<br />

No Yes No Yes No No No<br />

Centralized<br />

configuration<br />

Yes Yes Yes Yes Yes Yes Yes<br />

Distributed<br />

configuration<br />

Dimensions<br />

No No No No No No No<br />

Mounting<br />

dimensions in<br />

centralized<br />

configuration<br />

(W x H x D,<br />

without optical<br />

drive) in mm<br />

368 x 290 x 61 450 x 290 x 61 450 x 290 x 64 450 x 321 x 59 450 x 3<strong>80</strong> x 71 400 x 310 x 98 483 x 400 x 115<br />

Operator control 400 x 310 483 x 310 483 x 310 483 x 355 483 x 400 483 x 400 483 x 400<br />

unit (W x H) in mm (7 HU)<br />

(19", 7 HU) (19", 7 HU) (19", 8 HU) (19", 9 HU) (19", 9 HU) (19", 9 HU)<br />

Weight<br />

General features<br />

6.1 kg 6.6 kg 7.0 kg 6.6 kg 7.2 kg 7.4 kg 10.9 kg<br />

Accessories Touch protective Insertable strips Touch protective Insertable strips Touch protective Touch protective Touch protective<br />

membranes for keyboard membranes for keyboard membranes membranes membranes<br />

Power loss in 24 V DC: max. 24 V DC: max. 24 V DC: max. 24 V DC: max. 24 V DC: max. 24 V DC: max. 24 V DC: max.<br />

maximum configuration<br />

45 W<br />

45 W<br />

55 W<br />

55 W<br />

60 W<br />

55 W<br />

55 W<br />

5/209<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Embedded Panel <strong>PC</strong> bundles<br />

SIMATIC HMI I<strong>PC</strong>477C bundles<br />

■ Ordering data Order No. Order No.<br />

Bundles with WinAC RTX 2010<br />

and WinCC flexible 2008 SP2<br />

(Built-to-order version, delivery<br />

time max. 15 business days and<br />

with identified repair, if not<br />

preferred type)<br />

Configuration<br />

SIMATIC HMI I<strong>PC</strong>477C PRO E 6AV7 883 - 7 A 7 7 7 - 7 7 7 0<br />

Embedded and fan-free with fully<br />

enclosed IP65 enclosure<br />

4 x USB (500 mA), 24 V DC power<br />

supply with On/Off switch<br />

SIMATIC HMI I<strong>PC</strong>477C E 6AV7 884 - 7 A 7 7 7 - 7 7 7 0<br />

Fan-free<br />

5 x USB 2.0 (500 mA), one of<br />

which on the front<br />

1 x COM (RS232)<br />

24 V DC power supply with<br />

On/Off switch<br />

Front Panels 0<br />

12" TFT Touch 1) 1<br />

12" TFT Key 2<br />

15" TFT Touch 1) 3<br />

15" TFT Key 4<br />

19" TFT Touch 1) 5<br />

15" TFT Touch<br />

6<br />

(IP65 enclosure; PRO)<br />

19" TFT Touch<br />

7<br />

(IP65 enclosure; PRO)<br />

Processors and fieldbus<br />

Celeron M 1.2 GHz,<br />

2 x PROFINET (IE) 1)<br />

A<br />

Celeron M1 1.2 GHz,<br />

2 x PROFINET (IE),<br />

1 x PROFIBUS DP 12 1)<br />

B<br />

Core2 Solo 1.2 GHz,<br />

2 x PROFINET (IE) 1)<br />

D<br />

Core2 Solo 1.2 GHz,<br />

2 x PROFINET (IE),<br />

1 x PROFIBUS DP 12 1)<br />

E<br />

Core2 Solo 1.2 GHz,<br />

1 x PROFINET (IE),<br />

1 x PROFINET (3 ports) 1)<br />

F<br />

Core2 Duo 1.2 GHz,<br />

2 x PROFINET (IE) 1)<br />

G<br />

Core2 Duo 1.2 GHz,<br />

2 x PROFINET (IE),<br />

1 x PROFIBUS DP 12 1)<br />

H<br />

Core2 Duo 1.2 GHz,<br />

1 x PROFINET (IE),<br />

1 x PROFINET (3 ports) 1)<br />

J<br />

Main memory (DDR3 RAM),<br />

1 bank<br />

1 GB 1<br />

2 GB 1) 2<br />

4GB 3<br />

1) Preferred versions with repaired replacement device from warehouse<br />

5/210<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Bundles with WinAC RTX 2010<br />

and WinCC flexible 2008 SP2<br />

(Built-to-order version, delivery<br />

time max. 15 business days and<br />

with identified repair, if not<br />

preferred type)<br />

Configuration (continued)<br />

SIMATIC HMI I<strong>PC</strong>477C E 6AV7 884 - 7 A 7 77- 777 0<br />

Second mass storage<br />

(installed and formatted)<br />

Without 1) 0<br />

CompactFlash 2 GB (only with<br />

Windows Embedded Standard<br />

2009) 1)<br />

2<br />

CompactFlash 4 GB 1) 3<br />

CompactFlash 8 GB 1) 4<br />

SSD (Solid State Drive)<br />

6<br />

min. 32 GB<br />

Mass storage (installed, Windows<br />

Embedded Standard 2009<br />

(Eng/Ger) preinstalled, optionally<br />

with SIMATIC software)<br />

CompactFlash 2 GB 1) 2<br />

CompactFlash 4 GB 1) 3<br />

CompactFlash 8 GB 1) 4<br />

SSD (Solid State Drive)<br />

6<br />

min. 32 GB<br />

Operating system<br />

Windows Embedded 2009,<br />

pre-installed 1)<br />

B A<br />

Windows XP Professional Multi<br />

D A<br />

Language, only with SSD;<br />

without SIMATIC software<br />

Software packages,<br />

only with CF 4 GB or higher 1)<br />

with operating system and RTX<br />

B B<br />

WinAC RTX 2010 pre-installed<br />

and configured<br />

with operating system and<br />

HMI WinCC flexible 2008<br />

SP2 RT (incl. archives/recipes)<br />

pre-installed and configured<br />

- Number of tags 128 PT B C<br />

- Number of tags 512 PT B D<br />

- Number of tags 2048 PT B E<br />

- Number of tags 4096 PT B F<br />

with operating system and<br />

HMI/RTX WinCC flexible 2008<br />

SP2 RT (incl. archives/recipes)<br />

and WinAC RTX 2010 preinstalled<br />

and configured<br />

- Number of tags 128 PT B K<br />

- Number of tags 512 PT B L<br />

- Number of tags 2048 PT B M<br />

- Number of tags 4096 PT B N<br />

with operating system and RTX F<br />

B P<br />

WinAC RTX 2010 pre-installed<br />

and configured<br />

with operating system and<br />

HMI/RTX F<br />

WinCC flexible 2008 SP2 RT<br />

(incl. archives/recipes) and<br />

WinAC RTX F 2010 pre-installed<br />

and configured<br />

- Number of tags 128 PT B R<br />

- Number of tags 512 PT B S<br />

- Number of tags 2048 PT B T<br />

- Number of tags 4096 PT B U<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU


<strong>PC</strong>-based Automation<br />

Embedded Panel <strong>PC</strong> bundles<br />

■ Ordering data Order No. Order No.<br />

Bundles with WinCC V7.0 SP2,<br />

incl. Update 1<br />

("Built to order" with delivery time<br />

of max. 14 business days, for<br />

hardware only repairs are<br />

possible)<br />

Configuration<br />

SIMATIC HMI I<strong>PC</strong>477C E 6AV7 88 4 - 7 A 770 - 7 B 7 0<br />

Fan-free<br />

4 x USB 2.0 on rear, 1 x USB 2.0<br />

on front, 1 x COM (RS232),<br />

2 x 10/100/1000 Mbit/s Ethernet<br />

(RJ45); software pre-installed on<br />

CF/SSD:<br />

Windows Embedded Standard,<br />

SIMATIC WinCC V7.0 SP1<br />

SIMATIC HMI I<strong>PC</strong>477C PRO E 6AV7 88 3 - 7 A 770 - 7 B 7 0<br />

Fan-free, 4 x USB 2.0 (500 mA),<br />

1 x USB 2.0 on front (not on PRO),<br />

1 x COM (RS 232), 24 V DC power<br />

supply with On/Off switch,<br />

2 x PROFINET (IE), Windows<br />

Embedded 2009 pre-installed<br />

SIMATIC WinCC V7.0 SP2 incl.<br />

Update 1 Runtime pre-installed<br />

Front Panel<br />

15" TFT Touch 6AV7 88 4 2<br />

19" TFT Touch 6AV7 88 4 5<br />

15" TFT Touch PRO 6AV7 88 3 6<br />

19" TFT Touch PRO<br />

Client configurations<br />

6AV7 88 3 7<br />

Processor Celeron M 1.2 GHz,<br />

1 GB DDR3 RAM, 4 GB CF Card,<br />

runtime license 128 PT<br />

E 6AV7 88 7 - 7 A A10 -3BX0<br />

Client and single-user station<br />

configurations<br />

Processor Core2 Solo 1.2 GHz,<br />

2 GB SDRAM-DDR3, 8 GB CF<br />

Card, runtime license 128 PT<br />

Processor Core2 Solo 1.2 GHz,<br />

PROFIBUS DP, 2 GB<br />

SDRAM-DDR3, 8 GB CF Card,<br />

runtime license 128 PT<br />

Single-user station configurations<br />

Core2 Duo processor 1.2 GHz,<br />

PROFIBUS DP,<br />

4 GB SDRAM-DDR3<br />

E 6AV7 88 7 - 7 A D20 -4BX0<br />

E 6AV7 88 7 - 7 A E20 -4BX0<br />

E 6AV7 88 7 - 7 A H30 - 7 B 7 0<br />

8 GB CF Card E 6AV7 88 7 - 7 A H30 -4B 7 0<br />

32 GB SSD E 6AV7 88 7 - 7 A H30 -6B 7 0<br />

Runtime license 128 PT E 6AV7 88 7 - 7 A H30 - 7 BX0<br />

Runtime license 2048 PT E 6AV7 88 7 - 7 A H30 - 7 BW0<br />

1) Preferred versions with repaired replacement device from warehouse<br />

Note:<br />

Other ready-to-use SIMATIC HMI I<strong>PC</strong>477C can be found under<br />

HMI I<strong>PC</strong>477C.<br />

Further complete turnkey solutions (software pre-installed and<br />

configured) based on the Microbox <strong>PC</strong> can be found under<br />

SIMATIC <strong>PC</strong> based Control.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Please be sure to note:<br />

SIMATIC HMI I<strong>PC</strong>477C bundles<br />

Accessories<br />

Protective film for Panel <strong>PC</strong>s<br />

477/577/677<br />

For protecting the touch screen<br />

against dirt/scratches<br />

for 12" Touch 6AV7 671-2BA00-0AA0<br />

for 15" Touch (not for PRO) 6AV7 671-4BA00-0AA0<br />

for 19" Touch 6AV7 672-1CE00-0AA0<br />

Labeling membranes for Panel<br />

<strong>PC</strong>s 477/577/677<br />

For labeling soft keys and<br />

function keys, blank, supplied in<br />

sets of 10<br />

6AV7 672-0DA00-0AA0<br />

Touch pen<br />

Captive pen for operation of the<br />

touch devices, mounting of the<br />

support on the control cabinet or<br />

direct on the PRO unit<br />

Expansion components<br />

A 6AV7 672-1JB00-0AA0<br />

SIMATIC I<strong>PC</strong> DiagMonitor V4.2 B<br />

Software tool for monitoring<br />

SIMATIC <strong>PC</strong>s,<br />

incl. manual, on CD-ROM<br />

(German/English)<br />

6ES7 648-6CA04-2YX0<br />

SIMATIC I<strong>PC</strong> Image & Partition D<br />

Creator V3.1<br />

Software tool for preventive data<br />

backup and hard disk partitioning<br />

for SIMATIC <strong>PC</strong>s, incl.<br />

manual on CD-ROM (German,<br />

English)<br />

6ES7 648-6AA03-1YA0<br />

SIMATIC I<strong>PC</strong> USB FlashDrive<br />

8 GB, USB 2.0, metal enclosure,<br />

bootable<br />

A 6ES7 648-0DC50-0AA0<br />

SIMATIC I<strong>PC</strong> Service USB<br />

FlashDrive<br />

8 GB, USB 2.0, metal enclosure,<br />

bootable<br />

With: BIOS Manager, Image &<br />

Partition Creator pre-installed,<br />

incl. CD<br />

B 6AV7 672-8JD01-0AA0<br />

USB disk drive 3.5"<br />

with 1 m connecting cable<br />

A 6FC5 235-0AA05-1AA2<br />

Industrial USB Hub 4<br />

4 x USB 2.0, IP65 for control<br />

cabinet door or DIN rail<br />

CompactFlash Card<br />

A 6AV6 671-3AH00-0AX0<br />

2 GB A 6ES7 648-2BF02-0XF0<br />

4GB A 6ES7 648-2BF02-0XG0<br />

8 GB A 6ES7 648-2BF02-0XH0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

The HMI I<strong>PC</strong>477C is delivered as standard with an inserted<br />

CF card. The licenses are located on the supplied USB flash<br />

drive.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/211<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Software packages<br />

Software packages<br />

■ Overview<br />

SIMATIC I<strong>PC</strong> and S7-mEC with SIMATIC WinCC flexible<br />

SIMATIC I<strong>PC</strong> packages with WinCC flexible are an innovative<br />

solution for simple visualization tasks directly at the machine<br />

in the field of operator control and monitoring.<br />

This package can only be supplied if a SIMATIC I<strong>PC</strong> or<br />

S7-mEC (same quantity) is ordered together with the<br />

WinCC flexible Runtime software. It cannot be ordered<br />

subsequently.<br />

In combination with the embedded SIMATIC I<strong>PC</strong><br />

(HMI I<strong>PC</strong>477C (PRO) and I<strong>PC</strong>427C) and the<br />

Embedded Controller S7-mEC, there are turn-key solutions<br />

(bundles), i.e. the runtime software is already preinstalled.<br />

SIMATIC I<strong>PC</strong> with SIMATIC WinCC<br />

The SIMATIC I<strong>PC</strong> packages with WinCC make it easy to order<br />

all the components required for an OCM solution on the basis<br />

of a Panel <strong>PC</strong>.<br />

This package can only be supplied if a SIMATIC I<strong>PC</strong> or<br />

S7-mEC (same quantity) is ordered together with the<br />

WinCC flexible Runtime software. It cannot be ordered<br />

subsequently.<br />

In combination with the embedded SIMATIC I<strong>PC</strong><br />

(HMI I<strong>PC</strong>477C (PRO) and I<strong>PC</strong>427C) and the<br />

Embedded Controller S7-mEC, there are turn-key solutions<br />

(bundles), i.e. the runtime software is already preinstalled.<br />

SIMATIC I<strong>PC</strong> with SIMATIC WinAC RTX (F)<br />

The SIMATIC I<strong>PC</strong> packages with WinAC RTX make it easy to<br />

order all the components required for a control solution on the<br />

basis of an industrial <strong>PC</strong>.<br />

This package can only be supplied if a SIMATIC Industrial <strong>PC</strong><br />

(same quantity) is ordered together with the WinAC RTX<br />

Runtime software. It cannot be ordered subsequently.<br />

In combination with the embedded SIMATIC I<strong>PC</strong><br />

(HMI I<strong>PC</strong>477C (PRO) and I<strong>PC</strong>427C) and the<br />

Embedded Controller S7-mEC, there are turn-key solutions<br />

(bundles), i.e. the runtime software is already preinstalled.<br />

5/212<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Easy to order<br />

Cost savings in contrast to ordering components individually<br />

Optimally tuned hardware for the SIMATIC HMI software<br />

System-tested solution<br />

■ Design<br />

SIMATIC I<strong>PC</strong> and S7-mEC with SIMATIC WinCC flexible<br />

The order configurator gives you a free choice of how the<br />

SIMATIC Industrial <strong>PC</strong> hardware is configured – depending on<br />

individual requirements for display and system performance.<br />

Customers must install the desired WinCC flexible Runtime<br />

software and the communication hardware and software<br />

themselves. The WinCC flexible Runtime software is supplied<br />

with the devices. The package also contains the runtime options<br />

for WinCC flexible /Archives and WinCC flexible /Recipes.<br />

Runtime licenses are required for WinCC flexible Runtime. One<br />

of the offered licenses can be selected depending on the<br />

number of Power Tags required.<br />

The term PowerTags is used exclusively to describe process<br />

variables that have a process link to the controller.<br />

Variables without process link, constant limit values of variables,<br />

and messages are also available for additional system performance.<br />

SIMATIC I<strong>PC</strong> with SIMATIC WinCC<br />

The order configurator gives you a free choice of how the<br />

SIMATIC Industrial <strong>PC</strong> hardware is configured – depending on<br />

individual requirements for display and system performance.<br />

It is only necessary in this case to comply with the minimum<br />

requirements that WinCC places on the basic hardware.<br />

Minimum configuration:<br />

Processor: Pentium III 933 MHz or Celeron 650 MHz or higher<br />

12" or 15" display (at least 600 x <strong>80</strong>0 pixels resolution)<br />

Main memory expansion min. 512 MB<br />

Min. 10 GB with CD-ROM<br />

Windows 2000 Multilanguage or Windows XP Professional<br />

multi language<br />

For process communication, you can choose between the onboard,<br />

CP 5611-compatible PROFIBUS interface or the powerful<br />

modules CP 1613 for Industrial Ethernet and CP 5613 for<br />

PROFIBUS.<br />

From the configurator for the WinCC package, another order<br />

item can be selected that then contains the relevant<br />

WinCC software package and the communication module.<br />

Both order items are delivered together. Customers must install<br />

the communication hardware and the WinCC software<br />

themselves.<br />

Runtime licenses are required for WinCC Runtime. One of the<br />

offered licenses can be selected depending on the number of<br />

Power Tags required.<br />

The term Power Tags is used exclusively to describe process<br />

variables that have a process link to the controller. Variables<br />

without process link, constant limit values of variables, and<br />

messages are also available for additional system performance.


<strong>PC</strong>-based Automation<br />

Software packages<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Software packages<br />

■ Ordering data Order No. Order No.<br />

Configuration<br />

SIMATIC WinCC flexible<br />

package 1) 3)<br />

D 6AV6 623 - 2 7 A 0 0 - 0 A A 0<br />

(incl. archives and recipes)<br />

WinCC flexible 2008 Runtime<br />

128 Power Tags B<br />

512 Power Tags D<br />

2048 Power Tags F<br />

4096 Power Tags<br />

SIMATIC WinCC package<br />

G<br />

2) 6AV6 382 - 2 7 A 0 6 - 2 A X 0<br />

WinCC V6.2 SP3 Runtime 2)<br />

128 Power Tags<br />

256 Power Tags<br />

C<br />

D<br />

1024 Power Tags E<br />

8192 Power Tags H<br />

65536 Power Tags F<br />

SIMATIC WinCC package 2) WinCC V7.0 SP2 Runtime<br />

6AV6 382 - 2 7 A 0 7 - 0 A X 0<br />

2)<br />

SIMATIC WinAC RTX (F)<br />

package<br />

SIMATIC WinAC RTX<br />

128 Power Tags C<br />

512 Power Tags<br />

2048 Power Tags<br />

D<br />

E<br />

8192 Power Tags H<br />

65536 Power Tags<br />

SIMATIC WinCC (TIA Portal)<br />

F<br />

WinCC Runtime Advanced<br />

Package 1) 3)<br />

incl. Recipes + Logging<br />

6AV2 114 - 2 7 A 0 0 - 0 A A 0<br />

128 Power Tags B<br />

512 Power Tags D<br />

2048 Power Tags F<br />

4096 Power Tags H<br />

SIMATIC WinCC Runtime<br />

Professional Package 1) 3)<br />

6AV2 115 - 2 7 A 0 0 - 0 A A 0<br />

128 Power Tags B<br />

512 Power Tags D<br />

2048 Power Tags F<br />

4096 Power Tags H<br />

8192 Power Tags K<br />

65536 Power Tags M<br />

2) 3) B 6ES7 671-0RC08-6YA0<br />

SIMATIC WinAC RTX F 2) 3) B 6ES7 671-1RC08-6YA0<br />

Ready-to-use Panel <strong>PC</strong> 477B as<br />

a WinCC Standard Client<br />

WinCC V7.0 is already installed<br />

and set up on the 4 GB Compact-<br />

Flash Card as a standard client.<br />

The Panel <strong>PC</strong> 477B has a<br />

24 V DC power supply and has<br />

2x Ethernet 1 Gbit/s, 4x USB 2.0,<br />

1x COM1 (RS232).<br />

Available solutions:<br />

15" Touch, Celeron 1.0 GHz<br />

processor with 1 GB main<br />

6ES7 676-3RA20-0DS0<br />

memory<br />

15" Touch, Pentium M 1.4 GHz<br />

processor with 2 GB main<br />

E 6ES7 676-3GA30-0DS0<br />

memory<br />

19" Touch, Celeron 1.0 GHz<br />

processor with 1 GB main<br />

memory<br />

E 6ES7 676-6DA20-0DS0<br />

19" Touch, Pentium M 1.4 GHz 6ES7 676-6GC30-0DS0<br />

processor with 2 GB main<br />

memory<br />

1) Only if ordered together with a SIMATIC I<strong>PC</strong> or S7-mEC<br />

2)<br />

Only if ordered together with a SIMATIC I<strong>PC</strong><br />

3) The current version will always be supplied<br />

Note:<br />

For ordering data for Panel <strong>PC</strong>s and accessories, see configurators<br />

in "SIMATIC Panel <strong>PC</strong>s".<br />

Other ready-to-use SIMATIC I<strong>PC</strong>427C can be found in the<br />

Box <strong>PC</strong>s chapter under I<strong>PC</strong>427C bundles.<br />

■ More information<br />

Further information can be found on the Internet at:<br />

www.automation.siemens.com/simatic-hmi<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

5/213<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Industrial Monitors and Thin Clients<br />

SIMATIC Flat Panels<br />

■ Overview<br />

The Flat Panels are rugged industry-standard LCD monitors.<br />

Installation:<br />

- They are equally suited to installation in the machine, in<br />

control cabinets, consoles and booms or in 19" racks.<br />

- As a device with all-round IP65 protection for mounting on a<br />

supporting arm/stand<br />

Type of operator control:<br />

- Simple display devices without operator functionality<br />

- Optional devices with touch control<br />

- Rear connection of I/O devices (optional)<br />

5/214<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Rugged industrial design:<br />

- High shock and vibration resistance as well as extremely<br />

high electromagnetic compatibility make for a fail-safe and<br />

long-lasting design<br />

- Enclosure front in degree or protection IP65/NEMA4,<br />

resistant against dust and humidity<br />

- Enclosure version complete in degree of protection IP65 for<br />

mounting on supporting arm<br />

- Scratch-resistant, anti-glare mineral glass screen, providing<br />

high mechanical protection against pressure and scratching<br />

- Meets CE standard "Industry"<br />

Variety of versions<br />

No X-rays<br />

Lower energy requirement<br />

Fatigue-proof operation:<br />

- Wide reading angle of up to 170° horizontal and vertical<br />

- Sharp and high-contrast graphic display<br />

- No flickering, uniform brightness<br />

- Automatic display adjustment (Auto Adjust)<br />

Configuration using on-screen display (OSD)<br />

Small space requirement and low weight<br />

Long service life<br />

■ Application<br />

The Flat Panels are used wherever the <strong>PC</strong> computing unit and<br />

the operator/display unit must be installed remotely from one<br />

another for technical or application-related reasons.<br />

SIMATIC Flat Panels are suitable for direct connection to any <strong>PC</strong>,<br />

in particular, however, for use with the SIMATIC Box <strong>PC</strong> or<br />

SIMATIC Rack <strong>PC</strong>.


■ Design<br />

Rugged aluminum front<br />

TFT display in following sizes:<br />

- 12" / <strong>80</strong>0 x 600 pixels<br />

- 15" / 1024 x 768 pixels<br />

- 17" / 12<strong>80</strong> x 1024 pixels<br />

- 19" / 12<strong>80</strong> x 1024 pixels<br />

256K up to 16 million colors<br />

Anti-glare and hardened mineral glass screen<br />

Basic display or touch screen option<br />

24 V DC power supply, additional option with 100-240 V AC<br />

(50/60Hz)<br />

Can be located up to 5 m from the computing unit<br />

The following are included in the scope of supply of the built-in<br />

units:<br />

24 V connection plug<br />

Power supply cable (Europe) for version with AC power pack<br />

(power supply cables for other countries can be ordered as an<br />

accessory)<br />

VGA connection cable 1.8 m (other cable lengths and<br />

DVI cable available separately as accessories)<br />

USB Touch connection cables for Touch devices (other cable<br />

lengths available separately as accessories)<br />

Latch fastener<br />

Operating instructions, 2 languages (German and English)<br />

CD-ROM with hardware drivers and documentation<br />

The following are included in the scope of supply of the<br />

PRO devices:<br />

24 V connection plug<br />

Power supply cable (Europe) (power supply cables for other<br />

countries can be ordered as an accessory)<br />

Operating instructions, 2 languages (German and English)<br />

CD-ROM with hardware drivers and documentation<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Industrial Monitors and Thin Clients<br />

SIMATIC Flat Panels<br />

Special functions of extended versions<br />

Can be located up to 30 m from the computing unit<br />

Two rear USB interfaces<br />

Dimmable backlit display<br />

Combined AC and DC power supply<br />

EX22 approval for 17" and 19" devices<br />

Marine approvals<br />

Flat Panel PRO 15"/19" Touch devices<br />

For mounting on a support arm or stand<br />

IP65 all-round, enclosure type 4x<br />

15"/19" Touch display<br />

Rugged aluminum enclosure<br />

24 V DC power supply and 100-240 V AC (50/60 Hz)<br />

combined<br />

Two internal USB interfaces, one of which can be equipped<br />

with the accessory "USB service interface"<br />

Can be located up to 30 m from the computing unit<br />

Device can be adapted from above or below<br />

Direct connection to support arm systems from well-known<br />

manufacturers (e. g. Rittal, Bernstein, Rose, Rolec)<br />

Supports the internationally established standard<br />

VESA 75 / VESA 100 for adjustable mounting<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/215<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Industrial Monitors and Thin Clients<br />

SIMATIC Flat Panels<br />

■ Technical specifications<br />

Flat Panel<br />

Supply voltage<br />

12“ 15“ 17” 19“<br />

Supply voltage 24 V DC, additional option 24 V DC, additional option 24 V DC, additional option 24 V DC, additional option<br />

100-240 V AC<br />

100-240 V AC<br />

100/240 V AC<br />

100/240 V AC<br />

Permissible frequency range 47 - 63 Hz 47 - 63 Hz 47 - 63 Hz 47 - 63 Hz<br />

Power consumption, max.<br />

General features<br />

25 VA 35 VA 55 VA 55 VA<br />

Anti-glare and hardened mineral<br />

glass screen<br />

Yes Yes Yes Yes<br />

Line side switch No No No No<br />

Can be separate from the<br />

computer<br />

Display<br />

Optional up to 30 m Optional up to 30 m Optional up to 30 m Optional up to 30 m<br />

On-screen display (OSD)<br />

configuration<br />

Yes Yes Yes Yes<br />

Display version 12" TFT 15" TFT 17" TFT 19" TFT<br />

Visible area (HxV) in mm 246 x 184.5 304 x 228 304 x 228 376 x 301<br />

Viewing angle 140° x 120° 140° x 120° (min) 170° x 170° 170° x 170°<br />

Pixel pitch 0.3075 mm x 0.3075 mm 0.297 mm x 0.297 mm 0.297 mm x 0.297 mm 0.294 mm x 0.294 mm<br />

Resolution (W x H in pixels) <strong>80</strong>0 x 600 1024 x 768 12<strong>80</strong> x 1024 12<strong>80</strong> x 1024<br />

Refresh rate 60 - 75 Hz 60 - 75 Hz 60 - 75 Hz 60 - 75 Hz<br />

Line frequency 25 - 48 kHz 46.7 - 62.5 kHz 30 - <strong>80</strong> KHz 30 - <strong>80</strong> KHz<br />

Brightness/Contrast > 350 cd/m² / 450:1 > 260cd/m² / 350:1 > 300cd/m² / 300:1 > 300cd/m² / 300:1<br />

Number of colors 262k 16.7 million 16.7 million 16.7 million<br />

MTBF backlit display<br />

(at 25 °C, 24 h continuous duty)<br />

Type of operation<br />

50,000 h 50,000 h 50,000 h 50,000 h<br />

Touch screen analog-resistive, optional analog-resistive, optional analog-resistive, optional analog-resistive, optional<br />

Connection for mouse/keyboard/ Yes, at rear, optionally via Yes, at rear, optionally via Yes, at rear, optionally via Yes, at rear, optionally via<br />

barcode reader<br />

Degree of protection<br />

USB<br />

USB<br />

USB<br />

USB<br />

Front side according to<br />

EN 60529<br />

IP65 IP65 IP65 IP65<br />

Rear side according to<br />

EN 60529<br />

Certifications & standards<br />

IP20 IP20 IP20 IP20<br />

Certification cULus (UL 508), NEMA4 cULus (UL 508), NEMA4 cULus (UL 508), NEMA4 cULus (UL 508), NEMA4<br />

tested<br />

tested<br />

tested<br />

tested<br />

EMC<br />

Standards, approvals,<br />

certificates<br />

CE EN 55011 class A CE EN 55011 class A CE EN 55011 class A CE EN 55011 class A<br />

CE marking Yes Yes Yes Yes<br />

UL approval Yes Yes Yes Yes<br />

CCC marking<br />

Ambient conditions<br />

Yes Yes Yes Yes<br />

Vibration load during operation 1 g (10 m/s²) 1 g (10 m/s²) 1 g (10 m/s²) 1 g (10 m/s²)<br />

Shock loading during operation 5 g (50 m/s²) 5 g (50 m/s²) 5 g (50 m/s²) 5 g (50 m/s²)<br />

5/216<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Industrial Monitors and Thin Clients<br />

SIMATIC Flat Panels<br />

■ Technical specifications (continued)<br />

Flat Panel<br />

Temperature<br />

12“ 15“ 17” 19“<br />

Ambient temperature during<br />

operation<br />

Mounting<br />

5 to +50°C 5 to +50°C 5 to +45°C 5 to +45 °C<br />

Rack mounting No No No No<br />

Front mounting Yes (IP65) Yes (IP65) Yes (IP65) Yes (IP65)<br />

Angle of inclination for desk<br />

mounting<br />

Interfaces<br />

-20°/+70° -20°/+70° -20°/+70° -20°/+70°<br />

Graphic interface Standard VGA interface Standard VGA interface Standard VGA interface Standard VGA interface<br />

15-pin Sub D / digital 15-pin Sub D / digital 15-pin Sub D / digital 15-pin Sub D / digital<br />

DVI-D interface<br />

DVI-D interface<br />

DVI-D interface<br />

DVI-D interface<br />

Interface for Touch USB (V1.1) USB (V1.1) USB (V1.1) USB (V1.1)<br />

USB interface for touch screen<br />

Dimensions<br />

Optional Optional Optional Optional<br />

External dimensions (W x H x D)<br />

in mm<br />

400 x 310 x 61.5 483 x 310 x 54 483 x 400 x 56 483 x 400 x 56<br />

Installation cutout/device depth<br />

(W x H x D) in mm<br />

Weight<br />

368 x 290 x 51 450 x 290 x 54 449 x 3<strong>80</strong> x 56 449 x 3<strong>80</strong> x 56<br />

Weight, approx. 5 kg 6.4 kg 10.2 kg 10.2 kg<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/217<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Industrial Monitors and Thin Clients<br />

SIMATIC Flat Panels<br />

■ Ordering data Order No. Order No.<br />

Standard configuration<br />

Accessories<br />

Flat Panel Monitor A 6AV7 861 - 77770 - 7 A A 0 Cover foils<br />

Display size<br />

For protecting the touch screen 6AV7 671-2BA00-0AA0<br />

12" Standard 1 0<br />

against dirt<br />

and scratches<br />

12" Extended 1 1<br />

Pack with 10 units<br />

15“ 2 1<br />

for 12" Touch 6AV7 671-2BA00-0AA0<br />

19“ 3 1<br />

for 15" Touch 6AV7 671-4BA00-0AA0<br />

Operator functionality:<br />

for 19" Touch 6AV7 672-1CE00-0AA0<br />

Display devices without<br />

operator functionality<br />

A 1<br />

Mounting elements for<br />

Panel <strong>PC</strong> 57x/67x/Flat Panel<br />

6AV7 672-8KE00-0AA0<br />

Touch screen (analog/resistive)<br />

Power supply<br />

24 V DC<br />

(not for Extended versions since<br />

these always have AC and DC)<br />

T<br />

A0<br />

1<br />

1<br />

For screw mounting, e. g. in<br />

19" rack cabinet<br />

Touch pen A<br />

Undetachable pen for operation<br />

of the touch devices, mounting of<br />

6AV7 672-1JB00-0AA0<br />

100 to 230 V AC (incl. Euro<br />

power supply cable) and<br />

B 1<br />

the support on the control cabinet<br />

or directly on the PRO unit<br />

24 V DC<br />

Connection cables for<br />

Version<br />

Standard, Extended and PRO<br />

Standard, can be located up to<br />

0 1<br />

versions<br />

5 m away<br />

Video (VGA)<br />

Extended, can be located up to<br />

30 m away,<br />

1 1<br />

- 3.0 m<br />

- 5.0 m<br />

6AV7 860-0AH30-0AA0<br />

6AV7 860-0AH50-0AA0<br />

marine approvals<br />

Dimmable background illumination<br />

Ex22<br />

Video (DVI-D)<br />

- 3.0 m<br />

- 5.0 m<br />

6AV7 860-0BH30-0AA0<br />

6AV7 860-0BH50-0AA0<br />

Flat Panel Monitor<br />

USB for optional touch screen<br />

12" Key<br />

15" Key<br />

PRO 15" Touch<br />

A<br />

A<br />

A<br />

6AV7 861-1KB10-1AA0<br />

6AV7 861-2KB10-1AA0<br />

6AV7 861-5TB10-1AA0<br />

- 3.0 m<br />

- 5.0 m<br />

Connection cables for<br />

Extended and PRO versions<br />

6AV7 860-0CH30-0AA0<br />

6AV7 860-0CH50-0AA0<br />

PRO 19" Touch A 6AV7 861-6TB10-1AA0<br />

Cable set 10 m (DVI-D, CAT5<br />

cable(USB), USB transmitter<br />

module)<br />

A 6AV7 860-1EX21-0AA1<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

5/218<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Cable set 15 m (DVI-D, CAT5<br />

cable(USB), USB transmitter<br />

module)<br />

Cable set 20 m (DVI-D, CAT5<br />

cable(USB), USB transmitter<br />

module)<br />

Cable set 30 m (DVI-D, CAT5<br />

cable(USB), USB transmitter<br />

module)<br />

A 6AV7 860-1EX21-5AA1<br />

A 6AV7 860-1EX22-0AA1<br />

6AV7 860-1EX23-0AA1


■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical specifications.<br />

W<br />

W +1 (cutout)<br />

Installation cutout for Flat Panel<br />

400<br />

Flat Panel PRO 15" Touch Flat Panel PRO 19" Touch<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/industrial-lcd<br />

H +1 (cutout)<br />

H<br />

310<br />

67.85<br />

D<br />

90.85<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

10.5<br />

G_<strong>ST</strong><strong>80</strong>_XX_00238<br />

G_<strong>ST</strong><strong>80</strong>_XX_00350<br />

<strong>PC</strong>-based Automation<br />

Industrial Monitors and Thin Clients<br />

SIMATIC Flat Panels<br />

Touch devices Front dimensions Installation cutout<br />

W H W+1 H+1 D<br />

12" 400 310 368 290 51<br />

15" 483 310 450 290 55<br />

17" 483 400 450 3<strong>80</strong> 57<br />

19" 483 400 450 3<strong>80</strong> 57<br />

483<br />

SIMATIC FLAT PANEL<br />

400<br />

82<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

105<br />

G_<strong>ST</strong><strong>80</strong>_XX_00371<br />

5/219<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Industrial Monitors and Thin Clients<br />

SCD monitors<br />

■ Overview<br />

SCD monitors are LCD monitors in rugged industry design.<br />

5/220<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Built-in versions:<br />

Built-in units (for control cabinets, control desks, and booms)<br />

Desktop models only (19" display)<br />

Type of operator control:<br />

Strictly display units (desktop models only)<br />

Panels with touch control


■ Overview<br />

The SCD 19101 D/DT monitors are LCD desktop monitors for<br />

use in industry.<br />

Type of operator control:<br />

Simple display devices<br />

Panels with touch control<br />

■ Benefits<br />

Rugged industrial design:<br />

- High shock and vibration resistance as well as extremely<br />

high electromagnetic compatibility ensure failure safety and<br />

a long service life<br />

- Mineral glass screen, i.e. high mechanical protection against<br />

pressures and scratching<br />

- Meets CE standard "Industry"<br />

No X-rays<br />

Low energy requirement<br />

Fatigue-proof operation:<br />

- Large reading angle<br />

- Sharp and high-contrast graphic display<br />

- No flickering, uniform brightness<br />

- Automatic display adjustment (Auto Adjust)<br />

Configuration using on-screen display (OSD)<br />

Minimal space requirement and low weight<br />

Long service life<br />

■ Design<br />

Plastic enclosure<br />

19" TFT display<br />

Anti-glare and hardened mineral glass screen<br />

Simple display, touch screen<br />

Line frequency 30-<strong>80</strong> kHz<br />

Refresh frequency 50-72 Hz<br />

100 -240 V AC power supply<br />

Scope of delivery:<br />

Network connecting cable for AC power supply unit<br />

Connecting cables 1.8 m<br />

Operating instructions, 2 languages (German and English)<br />

CD-ROM with touch drivers<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Industrial Monitors and Thin Clients<br />

SCD desk monitors SCD 19101<br />

■ Technical specifications<br />

19" monitors<br />

General features<br />

Supply voltage<br />

SCD 19101-D/-DT<br />

Supply voltage 110/230 V AC<br />

Frequency/power consumption 47 - 63 Hz/30 VA<br />

Line side switch No<br />

Representation<br />

Display<br />

Full screen<br />

Display version 19" TFT<br />

Screen diagonals 19"<br />

visible area (HxV) in mm 359 x 287<br />

Viewing angle 170° x 170°<br />

Pixel pitch 0.28 x 0.28<br />

Optimum resolution (in pixels) 12<strong>80</strong> x 1024<br />

Refresh rate 30 - 100 Hz<br />

Line frequency 50 - 97 KHz<br />

Brightness/contrast (typical) 270 cd/m2/400:1<br />

Number of colors 16 million<br />

MTBF of backlit display<br />

(up to 50%, at 25 °C)<br />

Type of operation<br />

50,000 h<br />

Function keys No<br />

Membrane keyboard & piezo<br />

mouse<br />

No<br />

Touch screen<br />

Degree of protection<br />

Optional<br />

Degree of protection according to<br />

EN 60529<br />

Ambient conditions<br />

Temperature<br />

IP20<br />

- Ambient temperature during<br />

operation<br />

Interfaces<br />

0 to +40°C<br />

Interface design, analog video<br />

signal (VGA)<br />

Yes<br />

PS/2 interfaces for keyboard &<br />

mouse<br />

No<br />

Serial interface for touch screen<br />

Dimensions<br />

Optional/serial<br />

External dimensions (W x H x D) 465 x 444 x 91<br />

in mm<br />

(stand depth 240)<br />

Installation cutout/depth<br />

465 x 444 x 91<br />

(W x H x D) in mm<br />

(stand depth 240)<br />

Weight in kg 7<br />

■ Ordering data Order No.<br />

19" LCD monitors<br />

SCD 19101-D, desktop model<br />

A 6GF6 220-1DA01<br />

19" Touch LCD monitors<br />

SCD 19101-DT, desktop model<br />

A 6GF6 220-1DB01<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/221<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Industrial Monitors and Thin Clients<br />

SCD desk monitors SCD 19101<br />

■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical specifications.<br />

444<br />

5"<br />

SCD 19101-D/DT<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/industrial-lcd<br />

5/222<br />

15"<br />

393<br />

51<br />

287.6<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

465<br />

3<strong>80</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

160<br />

393<br />

47<br />

91 20<br />

240<br />

G_<strong>ST</strong><strong>80</strong>_XX_00031


■ Overview<br />

The SIMATIC HMI SCD 1900 is a rugged, industry-standard <strong>PC</strong><br />

monitor.<br />

It is used as operator control unit in all types of industrial and<br />

standard <strong>PC</strong>. Standard interfaces permit a wide range of<br />

possible applications.<br />

Built-in versions:<br />

Built-in devices (for control cabinets, control desks, and<br />

booms)<br />

19" built-in devices (for 19" racks)<br />

Type of operator control:<br />

Panels with touch control<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

<strong>PC</strong>-based Automation<br />

Industrial Monitors and Thin Clients<br />

SCD monitors 1900<br />

Rugged industrial design:<br />

- high shock and vibration resistance as well as extremely<br />

high electromagnetic compatibility ensure failure safety and<br />

a long service life<br />

- enclosure with degree of protection IP65 at the front,<br />

resistant against dust and humidity<br />

- meets CE standard "Industry"<br />

No X-rays<br />

Low energy requirement<br />

Fatigue-proof operation:<br />

- large reading angle<br />

- sharp and high-contrast graphic display<br />

- no flickering, uniform brightness<br />

- automatic display adjustment (Auto Adjust)<br />

Configuration using on-screen display (OSD)<br />

Minimal space requirement and low weight<br />

Long service life<br />

■ Design<br />

Rugged aluminum enclosure<br />

19" TFT display in widescreen design<br />

Rugged analog-resistive touch screen<br />

24 V DC, optionally with external 100 - 240 V AC power supply<br />

Can be located up to 5 m from the computing unit<br />

Scope of delivery:<br />

Network connecting cable for AC power supply unit<br />

Connecting cables 1.8 m, 5 m, 10 m or 20 m<br />

Operating instructions, 2 languages (German and English)<br />

CD-ROM with touch drivers and SW tools<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/223<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Industrial Monitors and Thin Clients<br />

SCD monitors 1900<br />

■ Technical specifications ■ Ordering data Order No.<br />

19" widescreen monitors<br />

General features<br />

Supply voltage<br />

SCD 1900<br />

Supply voltage<br />

Display<br />

24 V DC, optional 100/240 V AC<br />

Display version 19" TFT<br />

Screen diagonals 19" wide<br />

Visible area (HxV) in mm 359 x 287<br />

Viewing angle 85° x <strong>80</strong>°<br />

Pixel pitch 0.28 x 0.28<br />

Optimum resolution (in pixels) 1440 x 900<br />

Refresh rate 30 - 100 Hz<br />

Line frequency 50 - 97 KHz<br />

Brightness/Contrast (typical) 300 cd/m2 / 400:1<br />

Number of colors 16 million<br />

MTBF background illumination<br />

(up to 50%, at 25 °C)<br />

50,000 h<br />

Type of operation<br />

Degree of protection<br />

Degree of protection according to<br />

EN 60529<br />

Touch screen<br />

At the front IP65<br />

At the rear<br />

Ambient conditions<br />

IP20<br />

Ambient temperature during<br />

operation<br />

Interfaces<br />

Video signal<br />

0 to +45 °C<br />

Analog VGA<br />

Digital DVI-D<br />

Touch screen<br />

Dimensions<br />

USB<br />

External dimensions (W x H x D) 483 x 310 x 67<br />

in mm<br />

(81 with AC power supply)<br />

Installation cutout/depth<br />

450 x 290 x 67<br />

(W x H x D) in mm<br />

(81 with AC power supply)<br />

Weight in kg 10<br />

5/224<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SCD monitors 1900<br />

Accessories<br />

Cable for connection to the<br />

graphic interface of the <strong>PC</strong><br />

A 6AV7 862-2TA00-1AA0<br />

VGA cable 3.0 m 6AV7 860-0AH30-0AA0<br />

VGA cable 5.0 m 6AV7 860-0AH50-0AA0<br />

DVI-D cable, 3.0 m 6AV7 860-0BH30-0AA0<br />

DVI-D cable, 5.0 m<br />

USB cable for connecting the<br />

touch screen<br />

6AV7 860-0BH50-0AA0<br />

3.0 m 6AV7 860-0CH30-0AA0<br />

5.0 m 6AV7 860-0CH50-0AA0<br />

External power supply for<br />

SCD 1900<br />

100-230 V AC, 50-60 Hz; incl.<br />

mounting accessories for optional<br />

installation at the device.<br />

A 6AV7 860-2AD06-0AA0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H


■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical specifications.<br />

SCD 1900<br />

<br />

<br />

<br />

<br />

1<br />

S<br />

SCD 1900 with installed optional DC power supply unit<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/industrial-lcd<br />

483<br />

W+1 (cutout)<br />

<strong>PC</strong>-based Automation<br />

Industrial Monitors and Thin Clients<br />

<br />

<br />

<br />

1<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

1<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

H+1 (cutout)<br />

310<br />

G_<strong>ST</strong><strong>80</strong>_XX_00239<br />

<br />

1<br />

SCD monitors 1900<br />

<br />

<br />

G_<strong>ST</strong><strong>80</strong>_XX_00429<br />

<br />

<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

<br />

5/225<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Industrial Monitors and Thin Clients<br />

SIMATIC Thin Client<br />

■ Overview<br />

SIMATIC Thin Clients are very economical operator panels<br />

which can be used flexibly in various distributed applications.<br />

They can be used as (additional) operator stations on a<br />

SIMATIC industrial <strong>PC</strong> or also on a SIMATIC Panel.<br />

The following versions are available:<br />

The rack-mounting versions SIMATIC Thin Client 10" Touch<br />

and SIMATIC Thin Client 15" Touch<br />

The support arm version SIMATIC Thin Client PRO 15" Touch<br />

with a rugged and very compact aluminum enclosure which is<br />

completely IP65 protected<br />

The SIMATIC HMI Thin Client Ex is available for hazardous<br />

areas. This device differs technically from the devices<br />

mentioned above.<br />

5/226<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

SIMATIC Thin Clients offer a wide range of possible applications,<br />

used as either a second operator station for plant visualization<br />

on a Multi Panel or as a classic "Client" which communicates with<br />

a server (e.g. Microbox 427C) via VNC.<br />

Low-cost client/server architectures can be implemented with<br />

SIMATIC Thin Clients. A further advantage of SIMATIC Thin<br />

Clients: they communicate exclusively via Ethernet, thus<br />

permitting extremely simple coverage of even large distances to<br />

the server.<br />

The possibility of using SCADA and Office functionalities<br />

(e. g. WinCC, SAP, MS-Excel) directly on-site on the machine<br />

supports the vertical integration of the data flow from host<br />

systems down to the machine level (e.g. warehouse utilization).<br />

The SIMATIC Thin Client itself requires no installations, licenses<br />

or additional software.<br />

The following protocols are supported:<br />

Sm@rtAccess for plant visualization with WinCC flexible<br />

RDP (Remote Desktop Protocol) for SCADA and office<br />

functions<br />

VNC (Virtual Network Computing) for remote operation of a <strong>PC</strong><br />

As a Thin Client Unit on a SINUMERIK <strong>PC</strong>U/NCU<br />

Citrix ICA Client complex client/server architectures


■ Design<br />

SIMATIC Thin Client is installation-compatible with<br />

Multi Panels MP 277 (10") and MP 377 (12" and 15").<br />

The device has degree of protection IP54 (splash-proof),<br />

enclosure type 12 (indoor use only) and can be expanded with<br />

an options package to degree of protection IP65 (protected<br />

against water jets), enclosure type 4x/type 12 (indoor use only).<br />

In addition, the SIMATIC Thin Client has the following features:<br />

Ethernet interface for operating on PROFINET- and Ethernet<br />

networks (with Auto-Cross-Over function for one-to-one<br />

connections between server and client via Ethernet cable)<br />

TFT screen with 64K colors<br />

Resolution:<br />

- 640 x 4<strong>80</strong> pixels (10")<br />

- 1024 x 768 pixels (15")<br />

A mouse and a keyboard can be operated on the USB<br />

interface as external input media. The USB interface supports<br />

the industrial USB Hub 4.<br />

Printer and storage media are controlled via the host device<br />

Thin Clients support automatic parameterization via DHCP.<br />

As an alternative, you can also assign IP addresses manually.<br />

■ Mode of operation<br />

One or more SIMATIC Thin Clients are connected using Ethernet<br />

to a server (Multi Panel or <strong>PC</strong>). No local applications are<br />

executed on the devices themselves (apart from the integrated<br />

browser). All Thin Clients are provided with the faceplate by the<br />

server over the network, and display this faceplate without applications<br />

being installed on the Thin Client. Inputs on the Thin<br />

Client are transferred to the server and processed. Operation is<br />

carried out on the Thin Client as if one were working on the<br />

server itself. Operation is possible via Touch or with a keyboard<br />

or mouse connected to a USB port.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Function<br />

<strong>PC</strong>-based Automation<br />

Industrial Monitors and Thin Clients<br />

SIMATIC Thin Client<br />

Via the various protocols:<br />

Sm@rtAccess<br />

RDP (Remote Desktop Protocol)<br />

VNC (Virtual Network Computing)<br />

Citrix ICA<br />

SINUMERIK connection<br />

the Thin Clients communicate with a server.<br />

A Thin Client can access the SIMATIC WinCC flexible visualization<br />

software via Sm@rtAccess. The software is executed on<br />

a server: this can be an Operator Panel or an I<strong>PC</strong>. Two or more<br />

Thin Clients can be operated depending on the server's performance.<br />

The advantage: if the HMI project is changed, the<br />

modification need only be carried out once centrally on the<br />

server.<br />

Low-cost and flexible structures can also be produced for<br />

SCADA applications using Thin Clients. For example, the Thin<br />

Client can communicate as an HMI client with the<br />

WinCC SCADA software via RDP. A completely new feature is<br />

that a SINUMERIK <strong>PC</strong>U/NCU can now also be operated from a<br />

SIMATIC Thin Client.<br />

SIMATIC Thin Clients communicate with the classical "<strong>PC</strong> World"<br />

using standard network protocols such as RDP, VNC or Citrix.<br />

RDP is currently included in every Microsoft operating system<br />

and only needs to be activated. A Thin Client can access the<br />

desktop of the server via RDP and carry out remote operation.<br />

The use of VNC is also very popular. The main difference to RDP<br />

is that VNC displays a "cloned" desktop if two or more operator<br />

panels are connected.<br />

Via RDP – and with a non-server operating system – only one<br />

operator panel can be active at a time and operate the server. In<br />

this case, all other stations display the log-in window. Citrix is<br />

frequently used with highly complex client/server architectures.<br />

The principle: The applications which can be accessed by the<br />

clients are defined on the server. The clients themselves can<br />

then connect to the applications enabled on the server.<br />

■ Integration<br />

Commissioning is very simple. Configuration can be carried out<br />

locally - directly on the device - or also through remote access<br />

from a <strong>PC</strong> over the Web. The SIMATIC Thin Client only needs an<br />

IP address and a host device that it can communicate with.<br />

It does not require any local software installations or configurations.<br />

There is thus no need to backup/restore or update the<br />

projects, and total cost of ownership are significantly reduced.<br />

SIMATIC Thin Client can be operated in all systems in a<br />

PROFINET network or in Ethernet networks. As an alternative,<br />

a one-to-one connection with the host is also possible with an<br />

Ethernet cable. In this way, distances of 100 meters (with a<br />

switch, even greater distances are possible) can be bridged,<br />

which means a clear cost reduction compared with the standard<br />

remote operator fronts via USB/DVI cable.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/227<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Industrial Monitors and Thin Clients<br />

SIMATIC Thin Client<br />

■ Technical specifications<br />

6AV6 646-0AA21-2AX0 6AV6 646-0AB21-2AX0<br />

Product type designation<br />

Display<br />

10" Touch 15" Touch<br />

Size 10.4" 15.1"<br />

Display type<br />

Resolution (pixels)<br />

TFT, 65536 colors TFT, 65536 colors<br />

Resolution (WxH in pixel)<br />

Backlighting<br />

640 x 4<strong>80</strong> 1024 x 768<br />

MTBF backlighting (at 25 °C)<br />

Control elements<br />

about 50,000 hours about 50,000 hours<br />

Control elements Touch screen Touch screen<br />

Connection for mouse/keyboard/barcode reader<br />

Touch operation<br />

USB / USB USB / USB<br />

Touch screen<br />

Supply voltage<br />

Input voltage<br />

analog, resistive analog, resistive<br />

permissible range +19.2 V to +28.8 V DC +19.2 V to +28.8 V DC<br />

Supply voltage 24 V DC 24 V DC<br />

Processor<br />

Memory<br />

ARM, 266 MHz ARM, 266 MHz<br />

Type Flash / RAM Flash / RAM<br />

Usable memory for user data No info No info<br />

Interfaces 1 x Ethernet (RJ45) 1 x Ethernet (RJ45)<br />

USB port<br />

Industrial Ethernet<br />

1 x USB 1 x USB<br />

Industrial Ethernet interface<br />

Protocols<br />

WEB characteristics<br />

1 x Ethernet (RJ45) 1 x Ethernet (RJ45)<br />

HTTP Yes Yes<br />

HTML Yes Yes<br />

XML Yes Yes<br />

CSS Yes Yes<br />

Java Script<br />

Protocols (terminal link)<br />

Yes Yes<br />

Sm@rtAccess Yes Yes<br />

RDP Yes Yes<br />

EMC<br />

Emission of radio interference acc. to EN 55 011<br />

Emission of radio interferences acc. to<br />

EN 55 011 (limit class A)<br />

5/228<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Yes; EN 61000-6-4, interference emission:<br />

Intended for use in industrial areas.<br />

Yes; EN 61000-6-4, interference emission:<br />

Intended for use in industrial areas.<br />

Ambient conditions<br />

Operating temperature<br />

Operation (vertical installation)<br />

Storage/transport temperature<br />

0 °C to +50 °C 0 °C to +50 °C<br />

Transport, storage<br />

Relative humidity<br />

-20 °C to +60 °C -20 °C to +60 °C<br />

max. relative humidity 85%; (Storage) 85%; (Storage)<br />

Maximum permissible angle of inclination<br />

without external ventilation<br />

Degree and class of protection<br />

+/- 35 ° +/- 35 °<br />

Front IP54, NEMA 12, (when installed) IP54, NEMA 12, (when installed)<br />

Rear IP20 IP20<br />

Standards, approvals, certificates<br />

Certifications CE, cULus, C-TICK, NEMA 12 (when installed:<br />

IP54, enclosure type 12; optional IP65, enclosure<br />

type 4X/type 12 (6AV6671-6AP00-0AX0))<br />

CE, cULus, C-TICK, NEMA 12 (when installed:<br />

IP54, enclosure type 12; optional IP65, enclosure<br />

type 4X/type 12 (6AV6671-6AP00-0AX0))<br />

Dimensions<br />

Front of enclosure (W x H) 325 mm x 263 mm 400 mm x 310 mm<br />

Mounting cutout/device depth (W x H) 310 mm x 248 mm / 65 mm device depth 368 mm x 290 mm / 65 mm device depth<br />

Weight 2.2 kg 3.6 kg


<strong>PC</strong>-based Automation<br />

Industrial Monitors and Thin Clients<br />

■ Ordering data Order No. Order No.<br />

SIMATIC Thin Client<br />

10" Touch device D 6AV6 646-0AA21-2AX0<br />

15" Touch device<br />

Starter packages<br />

SIMATIC Thin Client with<br />

Sm@rtAccess<br />

(License to operate SmartAccess<br />

on the server)<br />

D 6AV6 646-0AB21-2AX0<br />

Touch device 10" with<br />

Sm@rtAccess license (panels)<br />

D 6AV6 653-6AA01-2AA0<br />

Touch device 15" with<br />

Sm@rtAccess license (panels)<br />

D 6AV6 653-6BA01-2AA0<br />

Touch device 15"PRO with<br />

Sm@rtAccess license (panels)<br />

D 6AV6 653-6CA01-2AA0<br />

Touch device 10" with<br />

Sm@rtAccess license for<br />

WinCC flexible 2008 Runtime<br />

D 6AV6 653-6DA01-2AA0<br />

Touch device 15" with<br />

Sm@rtAccess license for<br />

WinCC flexible 2008 Runtime<br />

D 6AV6 653-6EA01-2AA0<br />

Touch device 15" PRO with<br />

Sm@rtAccess license for<br />

WinCC flexible 2008 Runtime<br />

D 6AV6 653-6FA01-2AA0<br />

■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical specifications.<br />

Tolerance ± 1 mm.<br />

335<br />

309<br />

232.49<br />

SIMATIC Thin Client 10" Touch SIMATIC Thin Client 15" Touch<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/simatic-thin-client<br />

275<br />

247<br />

113.59<br />

106.71<br />

59.9<br />

30<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6.2<br />

G_<strong>ST</strong><strong>80</strong>_XX_00305<br />

Option packages<br />

SIMATIC Thin Client<br />

IP65 set<br />

(upgrade from IP54 to IP65)<br />

6AV6 671-6AP00-0AX0<br />

Touch pen SIMATIC HMI Touch A<br />

devices<br />

6AV7 672-1JB00-0AA0<br />

Cover membrane 10"<br />

(10 units per packing unit)<br />

6AV6 671-3DC00-0AX0<br />

Cover foils 15" 6AV6 574-1AD00-4EX0<br />

Accessories see HMI accessories<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

400<br />

366<br />

232.49<br />

310<br />

288<br />

113.59<br />

63.21<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

59.9<br />

30<br />

6.2<br />

G_<strong>ST</strong><strong>80</strong>_XX_00306<br />

5/229<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

RMOS3 real-time operating system<br />

RMOS3 real-time operating system<br />

■ Overview<br />

SICOMP RMOS3<br />

RMOS3 is a real-time and multitasking-capable operating<br />

system. In addition to real-time capability, which ensures fast<br />

response times, deterministic behavior is also an important<br />

feature. This guarantees response times within a short time<br />

interval.<br />

Rugged operating systems guarantee reliable behavior even<br />

under exceptional circumstances. RMOS3 has been optimized<br />

for use in embedded applications. In harsh environments, the<br />

rugged memory cards or CompactFlash memories can be used<br />

instead of hard disks. In addition, RMOS3 is suitable for<br />

operation with or without an operator.<br />

RMOS3 V3.50 Real-Time Operating System<br />

With the RMOS3 V3.50, Intel Core i processors with up to<br />

2 cores/4 threads are now also supported. The "Symmetric<br />

Multicore Processing" (SMP) mode makes it possible to<br />

implement complex applications that are simultaneously<br />

processed on multiple processor cores. RMOS3 V3.50 ensures<br />

that the cores are symmetrically utilized so that a performance<br />

increase of up to 100% can be achieved on the SIMATIC I<strong>PC</strong><br />

with 2 processors.<br />

The new RMOS3 real-time operating system is characterized by<br />

increased security thanks to memory protection, minimum<br />

interrupt response times and fast hard disk access. For<br />

SIMATIC I<strong>PC</strong>s, automation solutions based on C/C++ with<br />

demands for hard real time, deterministic response and high<br />

performance can now be created more easily, conveniently and<br />

with greater stability.<br />

5/230<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

RMOS3-GNU V3.0<br />

The RMOS3-GNU software package uses generally available<br />

Linux tools with which users can easily create real-time applications<br />

for RMOS3 on the SIMATIC I<strong>PC</strong>.<br />

The GNU-based software tools for Windows XP/Vista/Windows 7<br />

computers comprise the assemblers, C/C++ compilers, linkers<br />

and debuggers familiar in the Linux environment as well as the<br />

Eclipse development interface. The integrated cross debugger<br />

is useful for commissioning the customer application since the<br />

development and target system can be connected via TCP/IP.<br />

C/C++ header files and libraries are available for applications<br />

which use RMOS3 Version 3.30 or higher.<br />

RMOS3-TCP/IP V3.0<br />

The RMOS3-TCP/IP V3.0 software package offers the application<br />

developer a wide range of options for implementing<br />

TCP/UDP-based communication tasks running under the realtime<br />

operating system RMOS3, V3.40 or higher.<br />

Apart from the usual UDP and TCP protocols for application<br />

development, the new version of RMOS3-TCP/IP not only<br />

provides Address Resolution Protocol (ARP), Multicast and<br />

ICMP services (Ping), but also client services for the DHCP<br />

(Dynamic Host Configuration Protocol), DNS (Domain Name<br />

System), NTP (Network Time Protocol) and SMTP (Simple Mail<br />

Transfer Protocol).<br />

Together with the FTP programming interface and the Web<br />

server with process data connection, the programmer obtains<br />

numerous programming interfaces for even greater flexibility in<br />

communication.<br />

RMOS3-GRAPHX V1.0<br />

With the RMOS3-GRAPHX product, window-based, graphical<br />

user interfaces can be implemented with the RMOS3 real-time<br />

operating system Version V3.30 or higher.<br />

Extensive graphical libraries increase the user-friendliness of the<br />

system and support cost savings due to centralization of the<br />

control and operation on a CPU.<br />

With a Graphical User Interface (GUI), familiar from Windows,<br />

window displays can be implemented with the familiar command<br />

elements in the form of buttons, toolbars, scrollbars, selection<br />

lists and symbols as well as dialog boxes for prompts or inputs.<br />

BSP SIMATIC I<strong>PC</strong> V3.1 for RMOS3<br />

The Board Support package BSP-SIMATIC I<strong>PC</strong> V3.1 for RMOS3<br />

is a software package for supporting all interfaces<br />

(e.g. PROFINET onboard) and other onboard functions<br />

(e.g. battery monitoring, watchdog) for the following industrial<br />

<strong>PC</strong>s: SIMATIC Microbox <strong>PC</strong> 427B, SIMATIC I<strong>PC</strong>427C,<br />

SIMATIC Box <strong>PC</strong> 627B, SIMATIC I<strong>PC</strong>627C,<br />

SIMATIC Box <strong>PC</strong> 827B, SIMATIC Rack <strong>PC</strong> 647B,<br />

SIMATIC I<strong>PC</strong>647C, SIMATIC Rack <strong>PC</strong> 847B and<br />

SIMATIC I<strong>PC</strong>847C.


■ Overview<br />

RMOS3 is the real-time and multitasking-capable operating<br />

system from <strong>Siemens</strong> for implementing your automation solution<br />

with the programming languages C and C++. In mechanical<br />

engineering or in the manufacture of machine tools RMOS3 is<br />

used in test beds, packaging or printing machines where high<br />

response times in conjunction with open and closed-loop control<br />

tasks are required.<br />

The new RMOS3 real-time operating system is characterized by<br />

increased security thanks to memory protection, minimum<br />

interrupt response times and fast hard disk access.<br />

Furthermore, with the RMOS3 V3.50 version, Intel Core i<br />

processors with up to 2 cores/4 threads are now also supported.<br />

The "Symmetric Multicore Processing" (SMP) mode makes it<br />

possible to implement complex applications that are simultaneously<br />

processed on multiple processor cores. RMOS3 V3.50<br />

ensures that the cores are symmetrically utilized so that a performance<br />

increase of up to 100% can be achieved on the<br />

SIMATIC I<strong>PC</strong> with 2 cores.<br />

For SIMATIC I<strong>PC</strong>, automation solutions based on C/C++ with<br />

demands for hard real time, deterministic response and high<br />

performance can now be created more easily, conveniently and<br />

with greater stability.<br />

RMOS3 has been optimized for use on <strong>PC</strong> platforms in<br />

embedded systems and fulfills industrial requirements with<br />

respect to:<br />

Real-time and multitasking capability<br />

Deterministic features<br />

Ruggedness<br />

Scalability/memory requirements<br />

Operation with or without an operator<br />

Modern development tools<br />

Quality assurance<br />

Warranty conditions<br />

Service & Support<br />

■ Benefits<br />

More performance through Symmetric Multicore Processing<br />

(SMP)<br />

Through the support of Core i processors, complex<br />

applications can be processed simultaneously on multiple<br />

cores of the processor<br />

The symmetric utilization of multiple cores through RMOS3<br />

ensures a performance increase of up to 100% (combining<br />

SIMATIC I<strong>PC</strong> with two cores)<br />

The implementation of existing applications can be limited to<br />

one core if required: Effects such as deadlocks or CPU<br />

hopping can thus be avoided without changing the tried-andtrusted<br />

application.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

RMOS3 real-time operating system<br />

RMOS3 V3.50 real-time operating system<br />

Reliable execution of the programs ensures high availability<br />

of the system<br />

Memory protection for programs in FLAT memory module<br />

(GNU) through MMU (Memory Management Unit) for even<br />

greater reliability of execution for the user applications<br />

generated from RMOS3-GNU using the development tools<br />

Privilege level mechanisms for protection of the operating<br />

system code, operating system data and the operating<br />

system stacks from unauthorized access of user programs<br />

ensure reliable execution of the operating system<br />

Protected code areas for all applications implemented with<br />

paging mechanisms prevent unintentional, mutual overwriting<br />

of the program code, make program errors easier to find and<br />

reduce the time spent troubleshooting<br />

Stack overflow /underflow monitoring detects encroachment<br />

beyond the valid stack area for the application. Invalid<br />

memory accesses are prevented.<br />

Null-pointer detection prevents the use of uninitialized pointer<br />

variables<br />

Compatibility with existing programs (CAD-UL, GNU) thanks<br />

to starting in kernel mode<br />

Greater industrial compatibility thanks to high-speed data<br />

access on a rugged system<br />

Resistant to viruses, due to the closed system<br />

UDMA hard disk driver for rapid back-up of large data<br />

volumes<br />

Support of High Precision Event Timers (HPET) for long-term<br />

accurate time output for logging time events<br />

Support for APIC interrupt controllers with up to 24 highperformance<br />

interrupts for optimized utilization of the interrupt<br />

resources and improved real-time properties of the overall<br />

system<br />

Task cycle times starting with 10 microseconds permit the<br />

fastest control cycles on a task level<br />

Support for interrupt sharing on the <strong>PC</strong>I bus for the use of<br />

<strong>PC</strong>I modules<br />

Quick and easy start-up enhances user friendliness and<br />

serviceability<br />

Expanded configurable nucleus for the shortest start-up times<br />

on SIMATIC I<strong>PC</strong><br />

- Configuration over RMOS.INI is 100% compatible to<br />

RMOS3 V3.40<br />

- Configurable, up to 2 GB RAM disk for backing up temporary<br />

data<br />

- Configurable APIC, UDMA and HPET support<br />

Output of additional messages in case of error permit a "post<br />

mortem" analysis at the developer's workstation without<br />

hindering production.<br />

100% downward compatible operating system versions<br />

Revised integrated RMOS3 debugger and resource reporter<br />

for enhanced evaluation of equipment units<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/231<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

RMOS3 real-time operating system<br />

RMOS3 V3.50 real-time operating system<br />

■ Application<br />

Industrial automation with typical applications such as<br />

measurement and control technology,<br />

acquiring and processing data, signals or analog variables,<br />

positioning axes and calculating setpoint and actual values,<br />

and communicating with higher or lower level systems over<br />

widely distributed fieldbuses (TCP/IP, PROFINET IO,<br />

PROFIBUS DP, CAN),<br />

requires that a process can respond to an event within a defined<br />

time, i.e. that the response to such an event can be accurately<br />

predicted and reproduced regardless of the current system<br />

load.<br />

RMOS3 offers a comprehensive library of operating system calls<br />

and allows simple and fast implementation of your automation<br />

task in an object-oriented programming environment with the<br />

programming languages C and C++.<br />

5/232<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Typical applications for RMOS3 can be found in<br />

Mechanical engineering applications<br />

Plastic processing machines<br />

Honing and deburring machines<br />

Riveting machines<br />

Screw machines<br />

Turning machines<br />

Ring bending rolls<br />

Mixers<br />

Labeling machines<br />

Presses<br />

Compressors<br />

Vacuum pumps<br />

In factory automation:<br />

Wire production<br />

Cable configuration<br />

Printing works<br />

Corrugated cardboard production<br />

Packaging and production systems for the pharmaceutical,<br />

cosmetic and chemical industry<br />

In semiconductor technology:<br />

Chip handler<br />

Chip tester<br />

Placement systems<br />

In testing technology:<br />

Engine test stands<br />

Gear testbeds<br />

Exhaust testbeds<br />

Pressure testbeds<br />

Quality monitoring


■ Design<br />

RMOS3 impresses customers with its industrial compatibility as<br />

an embedded operating system for maximum response times in<br />

closed-loop and open-loop control tasks and is the basis for<br />

high-performance customer solutions with SIMATIC I<strong>PC</strong>.<br />

Due to the new properties of version V3.50, such as support of<br />

"Symmetric Multicore Processing" on Core i processors and<br />

long-term accurate time with the help of the HPET, its<br />

ruggedness, industrial compatibility and performance have<br />

been further enhanced. Memory protection for applications in<br />

the FLAT (GNU) memory module, APIC support for high-performance<br />

interrupt mode as well as UDMA support for faster<br />

access to mass memories are additional core elements of<br />

RMOS3.<br />

In combination with the widely used GNU development tools and<br />

the Eclipse development environment, the development of<br />

C/C++ based automation solutions is even more efficient.<br />

The configurable nucleus that has been available since<br />

RMOS3 V3.50 is already preconfigured and can be installed<br />

immediately and completely adapted to the hardware and<br />

software requirements of your target system via an initialization<br />

file. The configurable nucleus supports the <strong>PC</strong>s from the<br />

SIMATIC I<strong>PC</strong> range and is optimally coordinated with the<br />

available additional functions and the hardware features.<br />

RMOS3 runtime environment<br />

Development environment<br />

Configuration /<br />

communication<br />

Diagnostics / Debugging<br />

File management system /<br />

drivers<br />

Programming interface<br />

(API)<br />

Nucleus<br />

Target system<br />

UDMA<br />

USB<br />

BSP – Board Support Packages<br />

API – Application Programming Interface<br />

* Purchase from Trolltech - Nokia<br />

Diagnosis<br />

APIC, HPET<br />

Overview of the RMOS3 operating system structure<br />

Eclipse IDE<br />

GNU Debug Server<br />

Profiler<br />

Reporter<br />

RMOS3-API<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

RAM File Syst.<br />

DOS File Syst.<br />

EGA<br />

<strong>PC</strong>I<br />

<strong>PC</strong>-based Automation<br />

RMOS3 real-time operating system<br />

RMOS3 V3.50 real-time operating system<br />

With optional products and Board Support Packages (BSP) you<br />

can integrate additional functions and drivers into your application.<br />

The Board Support Package BSP-SIMATIC I<strong>PC</strong> V3.1 is<br />

the complete package for operating the following SIMATIC I<strong>PC</strong>s<br />

with RMOS3 V3.40 or higher:<br />

Microbox <strong>PC</strong> 427B and I<strong>PC</strong> 427C<br />

Box <strong>PC</strong> 627B and I<strong>PC</strong>627C<br />

Box <strong>PC</strong> 827B<br />

Rack <strong>PC</strong> 647B and I<strong>PC</strong>647C<br />

Rack <strong>PC</strong> 847B and I<strong>PC</strong>847C<br />

The additional RMOS3-GNU software package is available for<br />

development and for testing applications for RMOS3. The new<br />

development platform is based on the GNU tool chain wellknown<br />

and widely used in UNIX / Linux environments and<br />

contains all expansions necessary for developing RMOS3 applications.<br />

The Eclipse development interface and the integrated<br />

graphical cross debugger make it easier than ever to create<br />

applications for RMOS3.<br />

O<strong>PC</strong> / PMC<br />

3964R<br />

Serial<br />

C/C++ API<br />

GNU Compiler<br />

CLI<br />

Debugger<br />

Telnet client / server<br />

I/O-API<br />

RMOS3 Real-time Multitasking Nucleus<br />

SIMATIC I<strong>PC</strong><br />

CANopen<br />

Web server<br />

FTP client / server<br />

TCP / IP<br />

10/100 Mbit/s LAN<br />

Qt Designer*<br />

File manager<br />

Exception manager<br />

Web lib<br />

FTP lib<br />

TCP / UDP lib<br />

Gbit LAN<br />

RMOS3 V3.50<br />

RMOS3-GNU<br />

RMOS3-TCP/IP<br />

GraphX<br />

Communication /<br />

Field bus<br />

PROFINET IO<br />

PROFIBUS DP<br />

BasicCAN<br />

<strong>PC</strong> IO-API<br />

RMOS3-GRAPHX<br />

BSP-SIMATIC <strong>PC</strong><br />

Other products<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00487<br />

5/233<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

RMOS3 real-time operating system<br />

RMOS3 V3.50 real-time operating system<br />

■ Function<br />

Symmetric Multicore Processing (SMP) for maximum<br />

performance on Core i processors<br />

RMOS3 V3.50 now also supports Core i processors with up to<br />

2 cores/4 threads thanks to the new Symmetric Multicore<br />

Processing (SMP) mode. This mode makes it possible to<br />

implement complex applications that are simultaneously<br />

processed on multiple processor cores. RMOS3 V3.50 ensures<br />

that the cores are symmetrically utilized so that a performance<br />

increase of up to 100% can be achieved on the SIMATIC I<strong>PC</strong><br />

with two cores. A second <strong>PC</strong>, e. g. for visualization, can be<br />

omitted without performance loss. Taking into account the<br />

compatibility of existing applications, it can also be specifically<br />

connected to one core if required. Additional commands allow<br />

the implementation of the entire application to be limited to one<br />

individual core in order to avoid effects such as deadlocks or<br />

CPU hopping without changing the tried-and-tested application.<br />

Memory protection for high system availability<br />

The memory protection functionality for RMOS3 offers even more<br />

reliability for execution of the user applications created from<br />

RMOS3-GNU V3.0 using the development tools.<br />

The applications are started in a separate execution level<br />

through a privilege level mechanism and their memory accesses<br />

are managed by the operating system. The operating system<br />

code, data and stack are therefore protected from unauthorized<br />

access from user programs. This ensures reliable execution of<br />

the operating system.<br />

"Paging" mechanisms also protect the code areas of internal and<br />

external applications. This ensures reliable execution of all parts<br />

of the application and, in the event of an error, rapid localization<br />

of the actual cause. Time-consuming troubleshooting can<br />

therefore be avoided.<br />

This applies in particular to the new stack monitoring<br />

mechanism. It detects unauthorized exiting of the valid stack<br />

area. Unwanted memory accesses are therefore prevented.<br />

Null-pointer detection prevents the use of uninitialized pointer<br />

variables. Every access to the lowest page of the memory is<br />

detected. A page fault exception supports rapid error localization.<br />

More ruggedness and industrial suitability<br />

High Precision Event Timers (HPET), which are available on all<br />

B devices of the SIMATIC I<strong>PC</strong> product range, enable a long-term<br />

accurate time output for logging time events under<br />

RMOS3 V3.50. In continuous operation (24/7), the deviations of<br />

the system time per week can be reduced to approx. 9 seconds,<br />

this means a 90% reduction compared to the standard timer.<br />

A further reduction of the minimum task cycle times from 50 µs<br />

to 10 µs allows for even faster control cycles on a task level.<br />

5/234<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

High level of user-friendliness and serviceability<br />

For the "post mortem" analysis of defective applications,<br />

additional information on the crash site is issued. It can be used<br />

to localize the relevant area in the source code without having<br />

access to the defective system. This makes for fast troubleshooting<br />

without having to expend time and energy to reproduce<br />

the error or call a software specialist to the site. Troubleshooting<br />

does not interfere with production at the end customer and<br />

sporadic errors can be analyzed at the developer's office.<br />

Temporary files can be temporarily stored with version V3.50 on<br />

a virtual hard drive (up to 2 GB). The limit of 32 MB no longer<br />

exists and performance of the RAM disk driver has been further<br />

increased. This means that large data volumes can be collected<br />

during production and, if needed, transmitted via FTP to higherlevel<br />

stations for further analysis.<br />

Additional expansions to the RMOS3 V3.50 user console permit<br />

complete directory trees to be rapidly deleted and applications<br />

with up to 64 arguments to be started.<br />

For users and service personnel, the expanded, configurable<br />

RMOS3 nucleus for SIMATIC I<strong>PC</strong> offers greater convenience<br />

and shorter start-up times.<br />

Apart from the already familiar additional functions of the<br />

nucleus, such as easy configuration using the initialization file<br />

(RMOS.INI) or user-friendly adjusting of serial and LAN interfaces,<br />

the following expansions are available:<br />

Scandisk functionality for testing the integrity of the mass<br />

memory on booting to protect against data loss.<br />

Configurable APIC support with the possibility of cascading<br />

additional interrupt controllers.<br />

Configurable UDMA support for fast access to mass storage.<br />

A number of additional functions make it suitable for different<br />

hardware versions:<br />

Standardized access to CPU LEDs and temperature<br />

monitoring function<br />

Simple activation and parameterization of LAN interfaces<br />

Optional: Automatic configuration depending on CPU used<br />

The configurable nucleus is optimally prepared for additional<br />

hardware features. This supports fast and reliable implementation<br />

for the customer's application:<br />

Battery-backed SRAM memory or SRAM disk as an optional<br />

drive for saving temporary data in the event of a network<br />

failure<br />

Interrupt sharing on the <strong>PC</strong>I bus


© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

RMOS3 real-time operating system<br />

RMOS3 V3.50 real-time operating system<br />

■ Function (continued)<br />

■ Technical specifications<br />

Moreover, the configurable nucleus offers the following<br />

functions:<br />

Project-specific designation of the kernel for fast identification<br />

of the automation system.<br />

System requirements for the development system<br />

<strong>PC</strong> with Windows XP, Windows Vista or Windows 7<br />

Required software components:<br />

Startup messages and exception/general protection<br />

RMOS3 development environment as of RMOS3 V3.40<br />

messages are recorded in a LOG file for fast subsequent<br />

analysis of the system in the event of a fault.<br />

System flags for fast and reliable diagnosis of system states.<br />

RMOS3-GNU as of V2.1, compiler and development interface<br />

Board support packages (optional, module-specific<br />

expansion packages)<br />

The configurable nucleus already contains TELNET and FTP<br />

services for easy and low-cost remote maintenance of the target<br />

system over TCP/IP. This allows debugging and software<br />

System requirements for target system<br />

SIMATIC 427B/I<strong>PC</strong>427C<br />

updates both during the development and production phase. SIMATIC Box <strong>PC</strong> 627B/827B, I<strong>PC</strong>627C<br />

Additional functions for optimal use of the operating system SIMATIC Rack <strong>PC</strong> 647B/847B, I<strong>PC</strong>647C, I<strong>PC</strong>847C<br />

resources:<br />

Required software components:<br />

Fast cycle times which can be set to multiples of<br />

10 microseconds. In this way, for example, control algorithms<br />

can be executed in a fast 10-microsecond cycle.<br />

With the ASCII editor, which includes a file manager, data and<br />

RMOS3 V3.50 runtime environment (RMOS nucleus and<br />

service programs)<br />

Board support packages (optional, module-specific drivers)<br />

files and can be edited using a semi-graphical user interface. Product structure, listed acc. to development and runtime<br />

The file structure with its flexible and long file names is based licenses<br />

on the Windows standard. This makes it easier to exchange<br />

files between RMOS3 and Windows applications.<br />

Additional tools determine memory assignment, record the<br />

system load, check the versions of integrated libraries and<br />

Product name<br />

RMOS3 V3.50 EL<br />

RMOS3 V3.50 EL Update<br />

Description<br />

Single license for RMOS3<br />

development environment<br />

incl. a RMOS3 runtime license<br />

monitor the integrity of the data carrier.<br />

comprising<br />

The scope of delivery includes revised PDF documentation in<br />

electronic form. Bookmarks for the individual chapters as well<br />

Sources and libraries for<br />

application creation<br />

as linked references permit quick access to the description.<br />

RMOS3 runtime environment<br />

incl. loadable programs and<br />

TCP/IP stack and 10/100 Mbit/s<br />

LAN drivers<br />

Configurable RMOS3 Nucleus<br />

for the Use on SIMATIC I<strong>PC</strong>s<br />

Examples and documentation<br />

RMOS3-GNU V3.0 EL Single license for the GNU<br />

development tools incl.<br />

RMOS3-GNU V3.0 EL Update<br />

Compiler, linker, debugger and<br />

Eclipse IDE<br />

Special RMOS3 libraries for<br />

application creation<br />

Example projects and documentation<br />

BSP-SIMATIC I<strong>PC</strong> V3.1 EL 1) Single license for Microbox <strong>PC</strong><br />

BSP-SIMATIC I<strong>PC</strong> V3.1 EL<br />

Update 1)<br />

RMOS3-TCP/IP V3.0 EL 1)<br />

incl. German documentation<br />

RMOS3-TCP/IP V3.0 EL Update 1)<br />

1) Optional board support packages (BSP)<br />

427B/I<strong>PC</strong>427C/Box <strong>PC</strong> 627B/<br />

827B, I<strong>PC</strong>627C,<br />

Rack <strong>PC</strong> 647B/847B, I<strong>PC</strong>647C,<br />

I<strong>PC</strong>847C incl. a runtime license<br />

for BSP (no RMOS3 V3.50<br />

runtime license):<br />

Configurable nucleus<br />

Driver for<br />

USB, LAN, PROFINET IO,<br />

PROFIBUS DP, BasicCAN<br />

GNU example projects and<br />

documentation<br />

Master license for TCP/IP<br />

communication<br />

Application development with<br />

socket interface<br />

Programming interface for FTP<br />

RMOS3-<strong>PC</strong> IO V2.0 Free download as programming<br />

example with programming<br />

interface for access to <strong>PC</strong> I/O<br />

modules<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/235<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

RMOS3 real-time operating system<br />

RMOS3 V3.50 real-time operating system<br />

■ Technical specifications (continued)<br />

Product structure – Runtime licenses<br />

Product name Description<br />

RMOS3 V3.50 RT Single RMOS3 V3.50 runtime<br />

license<br />

RMOS3-TCP/IP V3.x RT 1) Single RMOS3 TCP/IP runtime<br />

license<br />

Required for application<br />

programs with socket interface<br />

RMOS3-CANopen168 1) Single runtime license with<br />

software package when the<br />

C<strong>PC</strong>I-COM168 module is used in<br />

networks with CANopen<br />

BSP-SIMATIC I<strong>PC</strong> RT V3.x 1) Single runtime license for BSP<br />

1) Optional board support packages (BSP)<br />

5/236<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Supported boot media<br />

Disk<br />

Hard disk<br />

IDE flash disk<br />

LAN (on request)<br />

Available drivers for RMOS3 V3.50<br />

The drivers described below are currently available for RMOS3 V3.50<br />

Keyboard PS2 keyboard<br />

USB keyboard 1)<br />

Serial, parallel Universal I/O driver (BYT driver) for<br />

character-oriented I/O devices<br />

COM driver for 3964(R) protocol<br />

Transmission mode and baud rate configurable<br />

Graphics EGA (text mode)<br />

Semi-graphical interface<br />

(function library on request)<br />

RMOS3-GRAPHX (graphics library for pixel<br />

graphics window displays)<br />

1) Optional board support packages (BSP)<br />

1)<br />

Ethernet 10/100/1000 Mbit/s LAN driver:<br />

Microbox <strong>PC</strong> 427B, I<strong>PC</strong>427C, Box <strong>PC</strong> 627B,<br />

I<strong>PC</strong>627C, Box <strong>PC</strong> 827B, Rack <strong>PC</strong> 647C,<br />

I<strong>PC</strong>647C, Rack <strong>PC</strong> 847B, I<strong>PC</strong>847C<br />

Filter functionality, configurable transfer rates<br />

and transfer modes<br />

USB 1) Optional USB driver for USB 1.1 protocol<br />

and USB 2.0 protocol<br />

Support for keyboard, mouse, hub<br />

memory stick and CD-ROM (on request)<br />

PROFINET IO Module driver for operating th<br />

CP 1616-compatible PROFINET components<br />

(CP 1616, CP 1604, SIMATIC I<strong>PC</strong> with<br />

PROFINET onboard)<br />

Supports the ERTEC 400 controller, RT and<br />

IRT, IO Controller and/or IO Device<br />

PROFIBUS DP 1) Module driver and programming interface<br />

for SIMATIC <strong>PC</strong> with PROFIBUS onboard,<br />

CP 5611 compatible, DPV0 master and/or<br />

slave<br />

CAN 1) BasicCAN driver for connection to CAN bus<br />

Supports the SJA1000 CAN controller on<br />

SIMATIC Microbox <strong>PC</strong> 427B / I<strong>PC</strong>427C


<strong>PC</strong>-based Automation<br />

RMOS3 real-time operating system<br />

RMOS3 V3.50 real-time operating system<br />

■ Ordering data Order No. Order No.<br />

RMOS3 V3.50 EL B 6AR1 405-0EA00-1AA4<br />

SICOMP RMOS3-TCP/IP V3.x B 6AR1 403-0BN3<br />

Single license for RMOS3<br />

Runtime license<br />

development environment<br />

Runtime license for TCP/IP<br />

incl. a RMOS3 runtime license<br />

software V3.0 or higher for use<br />

RMOS3 V3.50 EL Update B 6AR1 405-0EA50-1AA4<br />

with RMOS3 V3.40 or higher<br />

Update from V3.40 to V3.50.<br />

RMOS3-GRAPHX V1.0 EL D 6AR1403-0BG00-1AA0<br />

Single license for RMOS3 devel-<br />

Master license for graphics library<br />

opment environment incl. a<br />

for the creation of window-<br />

RMOS3 runtime license<br />

oriented interfaces of RMOS3<br />

RMOS3 V3.50 RT B 6AR1 403-0DA3<br />

Version 3.30 and higher<br />

Single RMOS3 V3.50 runtime<br />

license<br />

BSP-SIMATIC I<strong>PC</strong> V3.1 EL for<br />

RMOS3<br />

D 6AR1 403-0BC00-1CA1<br />

Accessories<br />

Board Support Package for<br />

SIMATIC Microbox <strong>PC</strong> 427B,<br />

RMOS3-GNU V3.0 EL B<br />

Single license for the GNU development<br />

tools incl. compiler, linker,<br />

debugger and Eclipse IDE,<br />

special RMOS3 libraries for<br />

creating applications, project<br />

examples and documentation<br />

6AR1 405-0BA00-1CA0<br />

I<strong>PC</strong>427C, Box <strong>PC</strong> 627B,<br />

I<strong>PC</strong>627C, Box <strong>PC</strong> 827B, Rack <strong>PC</strong><br />

647B, I<strong>PC</strong>647C, Rack <strong>PC</strong> 847B,<br />

I<strong>PC</strong>847C for use under the<br />

SICOMP RMOS3 operating<br />

system V3.40 and higher, development<br />

package, single license,<br />

runtime license, CD-ROM, incl.<br />

SICOMP RMOS3-GNU V3.0 EL B<br />

update<br />

Update V2.x to V3.0, development<br />

package, single license,<br />

CD-ROM, including description in<br />

6AR1 405-0BA50-1CA0<br />

description in German in PDF<br />

format, runtime license RMOS3<br />

V3.40 and higher not included<br />

BSP-SIMATIC I<strong>PC</strong> V3.1 EL<br />

Update<br />

D 6AR1 403-0BC50-1CA1<br />

German in PDF format<br />

Update from BSP-SIMATIC I<strong>PC</strong><br />

SICOMP RMOS3-TCP/IP B 6AR1 403-0AN00-1BA0<br />

V3.0 to BSP-SIMATIC I<strong>PC</strong> V3.1<br />

V3.0 EL<br />

BSP SIMATIC I<strong>PC</strong> V3.x RT D 6AR1 403-0CC3<br />

Development package, single<br />

license, TCP/IP software for<br />

RMOS3 V3.40 or higher,<br />

CD-ROM, including description in<br />

German in PDF format<br />

Runtime license for Board<br />

Support Package for<br />

SIMATIC Microbox <strong>PC</strong> 427B,<br />

I<strong>PC</strong>427C<br />

SIMATIC Box <strong>PC</strong> 627 B, I<strong>PC</strong>627C,<br />

SICOMP RMOS3-TCP/IP V3.0 B<br />

EL, update from V2.3 to V3.0<br />

Development package, single<br />

license, TCP/IP software for<br />

RMOS3 V3.40 or higher,<br />

CD-ROM, including description in<br />

German in PDF format<br />

6AR1 403-0AN50-1BA0<br />

SIMATIC Box <strong>PC</strong> 827B,<br />

SIMATIC Rack <strong>PC</strong> 647B, I<strong>PC</strong>647C,<br />

SIMATIC Rack <strong>PC</strong> 847B, I<strong>PC</strong>847C<br />

for use under the operating<br />

system SICOMP RMOS3, V3.40<br />

and higher.<br />

Runtime license RMOS3, V3.40<br />

and higher not included.<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/237<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

RMOS3 real-time operating system<br />

RMOS3-GNU V3.0<br />

■ Overview<br />

RMOS3-GNU V3.0 is a software package that supports development<br />

and testing of applications for the real-time operating<br />

system RMOS3 (Version 3.40 and higher).<br />

It builds on a GNU-based tool chain that is well-known and<br />

widely implemented in the Linux environment and contains the<br />

expansions required for RMOS3.<br />

RMOS3-GNU V3.0 replaces the existing RMOS3-GNU V2.x<br />

product. An update from RMOS3-GNU V2.x to Version V3.0 is<br />

available.<br />

RMOS3-GNU V3.0 contains the following new functions:<br />

Up-to-date versions of the GNU tool chain, e. g. C/C++<br />

compiler V3.4.1<br />

Updated versions of Eclipse V3.4 and CDT plug-in V5.0.<br />

New Eclipse "terminal" plug-in for remote operation of the<br />

target system<br />

New Eclipse "profiling" plug-in for determining the system load<br />

and the task activity on the target system<br />

Extended Eclipse "remote launcher" plug-in for testing the<br />

applications on Privilege Level 0 or alternatively on Privilege<br />

Level 1<br />

5/238<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Higher productivity on creating applications thanks to the<br />

following improvements:<br />

Shorter development times are achieved thanks to the<br />

GNU tools tested and released for RMOS3 with the C/C++<br />

compilers of version V3.4.1 suitable for multicore applications.<br />

Internal compiler optimization layers reduce the compilation<br />

time by up to <strong>80</strong>%, i.e. a 300 KB file can now be created in 15 s<br />

instead of <strong>80</strong> s under RMOS3-GNU V2.1. This provides an<br />

enormous potential for improvement of large projects with<br />

several Mbyte of data.<br />

Various code optimizations of the C/C++ compiler also ensure<br />

an increase in performance of up to 30% in the execution of<br />

programs. Improved code analysis during compilation means,<br />

for example, that constants are no longer calculated during<br />

runtime and simple program loops are calculated beforehand<br />

during compilation.<br />

The new versions of the Eclipse IDE V3.4 with the CDT<br />

plug-in V5.0 provide improved search functions, indexes and<br />

navigation as well as a revised editor complete with new<br />

highlight functions for variables: This makes execution of<br />

complex software much easier.<br />

New RMOS3 plug-ins for the Eclipse IDE support the<br />

developer with analyzing target systems: The terminal plug-in<br />

for remote operation and the profiling plug-in for easy<br />

measuring of the system load and the task activity on the<br />

target system.<br />

The improved remote launcher plug-in enables applications to<br />

be debugged alternatively in Privilege level PL0 or PL3.<br />

The improved debug interface between the development<br />

system and target system supports faster build-up for the<br />

debug link, improved multi-task debugging and premature<br />

termination of the debugging process.<br />

High degree of investment protection:<br />

RMOS3-GNU will be available long-term thanks to version<br />

updating and management through <strong>Siemens</strong>.<br />

High quality thanks to intensive testing of the GNU tools for<br />

RMOS3 (Version 3.40 and higher)<br />

High degree of flexibility and expendability for the Eclipse development<br />

environment thanks to the numerous downloadable<br />

plug-ins.<br />

■ Application<br />

RMOS3-GNU is the new development platform for RMOS3 in<br />

order to create and test your automation solution. The Eclipse<br />

graphical development interface offers software developers a<br />

modern development environment which includes an<br />

integrated, graphical cross debugger.


■ Design<br />

The RMOS3-GNU development package comprises the<br />

following components:<br />

GNU tool chain (comprising a compiler for C/C++, make-tool,<br />

assembler, linker and debugger)<br />

Integrated development environment Eclipse (including CDT<br />

plug-in for creating C/C++ programs) with the following<br />

RMOS3-specific expansions:<br />

- Simulation environment for RMOS3 applications<br />

- Project type plug-ins for RMOS3 applications and RMOS3<br />

libraries<br />

- Integrated RMOS3 online help and code completion<br />

- FTP plug-in for file transfer to the target system<br />

- Remote launcher plug-in for easy debugging on the target<br />

system<br />

- Terminal plug-in for remote operation of the target system<br />

- Profiling plug-in for determining the system load and the task<br />

activities on the target system<br />

NEW<br />

NEW<br />

ECLIPSE IDE<br />

Eclipse CDT plugin<br />

Terminal plugin<br />

Profiling plugin<br />

Remote Launch plugin<br />

FTP plugin<br />

Project type plugin<br />

RMOS3 help and<br />

Code Completion<br />

NEW<br />

GNU tool chain<br />

C and C++<br />

Standard libraries<br />

C und C++<br />

Standard header files<br />

(GNU alignment)<br />

Make, gcc, gdb, ...<br />

rm-gcc, rm-gdb, ...<br />

MSYS/MinGW<br />

Runtime DLL<br />

Java Runtime Environment<br />

Development system<br />

Updated versions of the GNU tools released for use with RMOS3:<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Windows XP / Windows Vista / Windows 7<br />

<strong>PC</strong>-based Automation<br />

RMOS3 real-time operating system<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

RMOS3-GNU V3.0<br />

GNU debug server for RMOS3<br />

Adaptation layer MSYS/MinGW for implementing the GNU tool<br />

chain, originally developed for UNIX, with Windows systems<br />

Programming and operating manual in PDF form, in German<br />

RMOS3<br />

development environment<br />

GNU expansions<br />

Documentation<br />

Examples<br />

RMOS3 simulation<br />

RMOS3 libraries<br />

Scope of delivery of<br />

RMOS3-GNU V3.0<br />

Not included in<br />

scope of delivery<br />

RMOS3<br />

runtime environment<br />

GNU debug server<br />

GDBSrvGn.386<br />

RMOS3 V3.40 or higher<br />

Target system: SIMATIC I<strong>PC</strong><br />

GNU tools RMOS3-GNU V1.0 RMOS3-GNU V2.0 RMOS3-GNU V2.1 RMOS3-GNU V3.0<br />

C-/ C++ compiler V3.3.1 V3.4.3 V3.4.3 V.4.3.0<br />

GNU debugger V5.3 V6.3 V6.3 V6.8<br />

GNU debug server V1.0.3 V1.2.5 V1.3.9 V1.4.1<br />

Binutil 1) V2.14 V2.14 V2.14 V2.18<br />

Eclipse IDE V2.1.1 V3.0.1 V3.2.1 V3.4.1<br />

Eclipse CDT plug-in V1.2.0 V2.1.1 V3.1.1 V5.0.1<br />

Cygwin V1.5.5-1 V1.5.12-1 V1.5.12-1 -<br />

MinGW/MSYS - - - V5.1.4/V1.0.10<br />

1) Assembler rm-as, linker rm-ld, object dump rm-objdump, archiver rm-ar.exe, striptool rm-strip, index creator for archiver rm-ranlib, display symbol<br />

rm-nm<br />

G_<strong>ST</strong><strong>80</strong>_XX_00484<br />

5/239<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

RMOS3 real-time operating system<br />

RMOS3-GNU V3.0<br />

■ Function<br />

RMOS3-GNU V3.0 is a further development of the new development<br />

platform for RMOS3 based on the GNU development<br />

tools and the integrated graphical development environment<br />

Eclipse. Apart from support for the current versions of Eclipse<br />

and CDT, the following functions are offered in combination with<br />

RMOS3:<br />

Terminal plug-in (new)<br />

The terminal plug-in creates a view in the Eclipse IDE that makes<br />

it possible to operate on one or more target systems via TELNET.<br />

This view is available during program development as well as<br />

during the debug phase. The view can assign a suitable, freely<br />

selectable name for easier identification of the respective target<br />

system.<br />

In addition to operating the RMOS3 system, the developer is<br />

also able to watch the messages from the RMOS3 applications,<br />

without the need to switch to other Telnet programs.<br />

Profiling plug-in (new)<br />

The profiling plug-in allows the user to investigate the load distribution<br />

and the task activity on the target system. The plug-in<br />

comprises the two views "Load Distribution" and "Task Activity".<br />

Load Distribution<br />

The "Load Distribution" view shows the percentage loading on<br />

the individual processor cores, as well as the percentage<br />

loading of the overall system per task, during one measurement.<br />

The loading on the CPU with one or two processor cores is<br />

shown in the left-hand part of the view with the help of bars.<br />

There is one bar per processor core for "Task" load, "S-State"<br />

interrupt load and "Idle Time". On the right-hand side, the load<br />

distribution for all tasks is shown in tabular form. The display can<br />

be sorted according to a column, by clicking the column header.<br />

The developer can use the "Load Distribution" display to gain an<br />

overview of the loading of the overall system and can sort the<br />

tasks to discover large consumers of computing time.<br />

Task Activity<br />

The "Task Activity" view displays the individual RMOS3 calls with<br />

a time stamp and the interrupts that are performed during a<br />

measurement.<br />

To analyze specific results, the data can be sorted, filtered and<br />

saved after measuring. The developer therefore has a convenient<br />

tool for analyzing the timing of events on the target system.<br />

5/240<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

RMOS3 simulation<br />

RMOS3 simulation allows RMOS3 programs to be pretested on<br />

the development <strong>PC</strong> with Windows using Eclipse. You can,<br />

therefore, work independently of the target hardware and start<br />

developing your automation solution early, and implement and<br />

test hardware-independent parts of your application.<br />

Remote launcher plug-in (extended)<br />

The remote launcher configuration can be used to transfer a<br />

generated application to the target system at the click of a<br />

button and to start it. Outputs from the program that is integrated<br />

in the Eclipse IDE are then displayed in the console.<br />

The remote launcher also allows an application to be debugged<br />

on the target system both in Privilege Level 0 and in Privilege<br />

Level 3 without the need to manually transfer the application to<br />

the target system and start the debug server.<br />

FTP plug-in<br />

The FTP plug-in included in the delivery package enables the<br />

created application to be downloaded from the Eclipse IDE to<br />

the target system. Switchover to additional FTP clients is no<br />

longer necessary. Downloading is performed at the click of a<br />

button.<br />

RMOS3 project type<br />

The project plug-in "Executable (GNU on RMOS)" as well as<br />

"Static Library (GNU on RMOS)" makes it easy to create new<br />

projects in the Eclipse IDE by presetting parameters. When the<br />

project is created, the required configuration "Release", "Debug"<br />

and/or "Simulation" can be selected. All the necessary compiler,<br />

linker and debugger settings have already been made and you<br />

can start creating and testing the program immediately.<br />

Code completion<br />

Code completion is offered in Eclipse IDE for the RMOS, CRUN<br />

and CLI functions. This support can be extended by reinstalling<br />

additional RMOS3 products (e. g. BSP SIMATIC I<strong>PC</strong> V3.0,<br />

RMOS3 TCP/IP V2.3).<br />

To use code completion, you simply type the first characters of<br />

the required function and press "CTRL+SPACE". A selection box<br />

is then displayed containing a list of all functions that start with<br />

these letters. The type of return parameter and the parameters<br />

complete with their data are also displayed.<br />

When you select a function, it will be inserted at the current<br />

cursor position. The cursor waits at the first parameter or void<br />

function behind the closing bracket. For functions with several<br />

parameters, use the "TAB" button to jump from one parameter to<br />

the next.<br />

Error messages from the compiler caused by typing mistakes<br />

can therefore be prevented and the expected parameter types<br />

can be immediately recognized, so there is no need to refer to<br />

the documentation.


© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

RMOS3 real-time operating system<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

RMOS3-GNU V3.0<br />

■ Function (continued)<br />

■ Technical specifications<br />

RMOS3 help function<br />

System requirements: Development system<br />

A help function is also available in German for the RMOS3 calls, Windows XP, Windows Vista, or Windows 7<br />

the CRUN calls and the CLI calls. This support can be extended<br />

Java Runtime Environment, Version 1.5 and higher<br />

by reinstalling additional RMOS3 products<br />

(only necessary when using Eclipse IDE)<br />

(e. g. BSP SIMATIC I<strong>PC</strong> V3.0, RMOS3 TCP/IP V2.3).<br />

RMOS3 development environment RMOS3 Version 3.40<br />

You open the help either via the Help menu of Eclipse or by (incl. software fix RMOS3 V3.40.02) or RMOS3 V3.50<br />

pressing the "F1" key after positioning the cursor on the required (incl. software fix RMOS3 V3.50.04)<br />

function call. You receive a detailed description of the call with<br />

additional links to related function calls that is similar to the System requirements: Target system<br />

description of function calls in the RMOS3 reference manuals. RMOS3 version 3.40.02 and higher or version 3.50.04<br />

Debugger<br />

(configurable nucleus V3.30.06 R01)<br />

The debugger integrated into Eclipse offers convenient<br />

Licenses<br />

functions for testing your application in simulation mode on your The GNU-based tool chain is subject to the<br />

development computer and via the Ethernet coupling to the GNU GENERAL PUBLIC LICENSE (GPL) or<br />

RMOS3 target system.<br />

the GNU LESSER GENERAL PUBLIC LICENSE (LGPL).<br />

The connection to the RMOS3 target system is built up via the<br />

Please read the licensing rules supplied with the product.<br />

GNU debug server which can be used under RMOS3 V3.40 as<br />

well as under RMOS3 V3.50:<br />

Quick and easy starting of the GNU debug server:<br />

The GNU debug server on the RMOS3 target system can also<br />

be started without specifying the IP address and port number.<br />

The IP address of the RMOS3 computer on which the<br />

GDB server is started is used here as the IP address. The<br />

default port number used is 8200.<br />

Debugging of executing applications:<br />

It is possible at any time to connect the main task of the<br />

application as well as the child tasks created by the main task<br />

using the option "Attach" and to debug them. There is no need<br />

for time-consuming adjustment of the behavior of the<br />

application under the control of the debugger.<br />

Source code display for general protection errors:<br />

It is also possible to connect to an application in which an<br />

exception has occurred. After connecting to the GNU debug<br />

server, the destination in the source text is then shown in which<br />

an exception has occurred.<br />

5/241<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

RMOS3 real-time operating system<br />

RMOS3-GNU V3.0<br />

■ Ordering data Order No. Order No.<br />

SICOMP RMOS3-GNU V3.0 EL B 6AR1 405-0BA00-1CA0<br />

SICOMP RMOS3-TCP/IP V3.x B 6AR1 403-0BN3<br />

Single license for the GNU devel-<br />

Runtime license<br />

opment tools incl. compiler, linker,<br />

Runtime license for TCP/IP<br />

debugger and Eclipse IDE,<br />

software V3.0 or higher for use<br />

special RMOS3 libraries for<br />

with RMOS3 V3.40 or higher<br />

creating applications, project<br />

examples and documentation<br />

RMOS3-GRAPHX V1.0 EL D 6AR1403-0BG00-1AA0<br />

SICOMP RMOS3-GNU V3.0 EL<br />

update<br />

B 6AR1 405-0BA50-1CA0<br />

Master license for graphics library<br />

for the creation of windoworiented<br />

interfaces of RMOS3<br />

Update V2.x to V3.0, devel-<br />

Version 3.30 and higher<br />

opment package, single license,<br />

CD-ROM, including description in<br />

BSP-SIMATIC I<strong>PC</strong> V3.1 EL D 6AR1 403-0BC00-1CA1<br />

German in PDF format<br />

Board Support Package for<br />

Accessories<br />

SIMATIC Microbox <strong>PC</strong> 427B,<br />

I<strong>PC</strong>427C, Box <strong>PC</strong> 627B,<br />

SICOMP RMOS3 V3.50 EL B 6AR1 405-0EA00-1AA4<br />

I<strong>PC</strong>627C, Box <strong>PC</strong> 827B,<br />

Development package, single<br />

license, CD-ROM, including<br />

description in German in PDF<br />

format<br />

Rack <strong>PC</strong> 647B, I<strong>PC</strong>647C,<br />

Rack <strong>PC</strong> 847B, I<strong>PC</strong>847C for use<br />

under the SICOMP RMOS3<br />

operating system V3.40 and<br />

higher, development package,<br />

SICOMP RMOS3 V3.50 EL B<br />

update<br />

Update V3.40 to V3.50, development<br />

package, single license,<br />

runtime license, CD-ROM,<br />

including description in German<br />

in PDF format<br />

6AR1 405-0EA50-1AA4<br />

single license, runtime license,<br />

CD-ROM, incl. description in<br />

German in PDF format, runtime<br />

license RMOS3 V3.40 and higher<br />

not included.<br />

BSP-SIMATIC I<strong>PC</strong> V3.1 EL D<br />

Update<br />

6AR1403-0BC50-1CA1<br />

SICOMP RMOS3 V3.50 RT<br />

Runtime license for SICOMP<br />

RMOS3 operating system V3.50<br />

B 6AR1 403-0DA3<br />

Update from BSP-SIMATIC I<strong>PC</strong><br />

V3.0 to BSP-SIMATIC I<strong>PC</strong> V3.1.<br />

BSP SIMATIC I<strong>PC</strong> V3.x RT D 6AR1403-0CC3<br />

SICOMP RMOS3-TCP/IP B<br />

V3.0 EL<br />

Development package, single<br />

license, TCP/IP software for<br />

RMOS3 V3.40 or higher,<br />

CD-ROM, including description in<br />

German in PDF format<br />

6AR1 403-0AN00-1BA0<br />

Runtime license for Board<br />

Support Package for<br />

SIMATIC Microbox <strong>PC</strong> 427B,<br />

I<strong>PC</strong>427C<br />

SIMATIC Box <strong>PC</strong> 627B, I<strong>PC</strong>627C,<br />

SIMATIC Box <strong>PC</strong> 827B,<br />

SIMATIC Rack <strong>PC</strong> 647B,<br />

I<strong>PC</strong>647C, SIMATIC Rack <strong>PC</strong><br />

SICOMP RMOS3-TCP/IP V3.0<br />

EL, update from V2.3 to V3.0<br />

Development package, single<br />

license, TCP/IP software for<br />

RMOS3 V3.40 or higher,<br />

CD-ROM, including description in<br />

German in PDF format<br />

B 6AR1 403-0AN50-1BA0<br />

847B, I<strong>PC</strong>847C for use under the<br />

operating system SICOMP<br />

RMOS3, V3.40 and higher.<br />

Runtime license RMOS3, V3.40<br />

and higher not included.<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

5/242<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Overview<br />

The RMOS3-TCP/IP V3.0 software package provides libraries for<br />

the quick and easy generation of TCP/IP, FTP and Web applications.<br />

In addition, the software package offers FTP and Telnet<br />

services for the exchange of files and for the remote mainte-<br />

■ Benefits<br />

Quick and easy generation of TCP/IP, FTP and Web<br />

applications<br />

Enhanced performance due to optimized TCP/IP stack.<br />

DHCP, DNS, NTP and SMTP for even greater flexibility during<br />

integration into existing network structures.<br />

Web server for central access to distributed/remote<br />

automation solutions, the visualization of process data in a<br />

browser and for the operation of headless systems<br />

(e. g. for commissioning and maintenance purposes).<br />

■ Application<br />

The RMOS3-TCP/IP V3.0 software package offers the application<br />

developer a wide range of options for implementing<br />

TCP/UDP-based communication tasks running under the<br />

real-time operating system RMOS3, V3.40 or higher.<br />

Apart from the usual UDP and TCP protocols for application<br />

development, the new version of RMOS3-TCP/IP not only<br />

provides Address Resolution Protocol (ARP), Multicast and<br />

ICMP services (Ping), but also client services for the DHCP<br />

■ Design<br />

Content of the RMOS3-TCP/IP V3.0 software package<br />

An overview of the components provided by<br />

RMOS3-TCP/IP V3.0 is shown in the following product structure:<br />

RMOS3 development environment<br />

Documentation<br />

RMOS3-TCP/IP V3.0<br />

Libraries for<br />

• Socket functions<br />

• FTP functions<br />

• ICMP, NTP and SMTP functions<br />

• WEB Server interface for variables<br />

Eclipse plugins (V2.1 or higher)<br />

• Online help<br />

• Code Completion<br />

• Simulation<br />

Examples:<br />

• ECHOS / ECHOC,<br />

• NECHOS / NECHOC,<br />

• ICMP, FT<strong>PC</strong>OM,<br />

• SMTP, NTP, WEB<br />

RMOS3-GNU V2.1 or higher<br />

Windows 7 / Vista / XP<br />

Development system<br />

RMOS3-TCP/IP V3.0 replaces Version V2.3.<br />

An update to Version V3.0 is available.<br />

Scope of delivery RMOS3-TCP/IP V3.0<br />

DHCP Client<br />

NEW<br />

NEW<br />

SMTP Client DNS Client<br />

TELNET<br />

Client/Server<br />

ROUTECFG<br />

SYSLOG<br />

DHCP<br />

(dyn. host con-<br />

figuration protocol)<br />

ICMP (Ping)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

RMOS3 real-time operating system<br />

RMOS3-TCP/IP V3.0<br />

nance of the RMOS3 system. New additions are the DHCP, DNS,<br />

NTP and SMTP services for even greater flexibility in communication.<br />

Standardized interface to existing systems with different<br />

operating systems (e. g. Windows 7 / XP, QNX, VxWorks,<br />

LINUX).<br />

Easy creation and simulation of the application using<br />

prepared GNU example projects.<br />

Total integration of the software packages into the new<br />

development landscape RMOS3-GNU V2.1 or higher<br />

(Online Help, Code Completion, Simulation).<br />

(Dynamic Host Configuration Protocol), DNS (Domain Name<br />

System), NTP (Network Time Protocol) and SMTP (Simple Mail<br />

Transfer Protocol).<br />

Together with the FTP programming interface and the Web<br />

server with process data connection, the programmer obtains<br />

numerous programming interfaces for even greater flexibility in<br />

communication.<br />

TCP/IP Utilities<br />

FTP<br />

Client/Server<br />

ADDROUTE<br />

PING<br />

Not incl. in scope of delivery<br />

RMOS3 runtime environment<br />

DNS<br />

(domain name<br />

system)<br />

IGMP (Multicast)<br />

NTP Client<br />

WEB<br />

Server<br />

DELROUTE<br />

TC<strong>PC</strong>ONF<br />

TCP/IP diagnostic<br />

ARP<br />

RMOS3 V3.40 or higher<br />

SMTP<br />

(simple mail transfer<br />

protocol)<br />

TCP/IP-Stack (IPv4, AF_INET)<br />

Target system: SIMATIC I<strong>PC</strong><br />

RMOS3-TCP/IP V3.0<br />

TCP<br />

TCP/IP diagnostics<br />

I<strong>PC</strong>ONF<br />

ARP<br />

NTP<br />

(network time<br />

protocol)<br />

UDP<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

NEW<br />

G_<strong>ST</strong><strong>80</strong>_XX_00485<br />

5/243<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

RMOS3 real-time operating system<br />

RMOS3-TCP/IP V3.0<br />

■ Function<br />

The RMOS3-TCP/IP V3.0 software package contains a<br />

completely newly adapted TCP/IP protocol stack<br />

(TCPIP.DRV V3.0) with a data transmission time 30% less than<br />

that of RMOS3-TCP/IP V2.3.<br />

RMOS3-TCP/IP V3.0 provides new communication services<br />

for the communication with higher-level server applications:<br />

DHCP client features<br />

The dynamic host configuration protocol (DHCP) allows the<br />

automatic configuration of IP addresses and subnetwork masks<br />

in a network. With the aid of a DHCP server, it is possible to<br />

integrate a computer (client) into an existing network without<br />

having to configure it manually. The complexity of administering<br />

the address configurations is reduced by the central administration<br />

of the IP addresses by means of a network server. Only<br />

the automatic reference of the IP address has to be set on the<br />

client. When starting the computer on the network, the client can<br />

obtain the IP address, the network mask, the gateway, the<br />

DNS server, etc. from the DHCP server.<br />

Advantage:<br />

This avoids collisions with manually set IP addresses that have<br />

accidentally been duplicated in a network, thus saving the<br />

consequential time-consuming troubleshooting.<br />

DNS client features<br />

The Domain Name System (DNS) is a distributed database for<br />

the central administration of the name space on the Internet. It<br />

compiles IP addresses into names (domains) or names into<br />

IP addresses, so that the computers and services can be<br />

addressed by means of user-friendly names.<br />

Advantage:<br />

When an IP address is dynamically assigned by means of DHCP,<br />

a specific <strong>PC</strong> can be addressed using a memorable, machinelevel<br />

working name, thereby simplifying remote maintenance via<br />

the Web server.<br />

NTP client features<br />

The Network Time Protocol (NTP) is used for synchronizing the<br />

time between different computers in the network. The network<br />

time is queried by an NTP server, which ideally is synchronized<br />

using atomic clocks. A coordinated universal time (UTC) is then<br />

transmitted.<br />

Advantages of automatic synchronization by means of NTP:<br />

Automatic setting of the computer clock - even if there are<br />

several computers in a network. By avoiding the use of<br />

CMOS batteries, completely maintenance-free SIMATIC I<strong>PC</strong><br />

solutions can be implemented, e. g. with the I<strong>PC</strong>427C.<br />

SMTP client features<br />

The SMTP protocol is used for sending e-mails to an<br />

SMTP server. The protocol is used predominantly for feeding<br />

and forwarding e-mails.<br />

Advantage:<br />

By means of a prepared function call, the machine can send the<br />

service engineer an e-mail without delay to notify him of any<br />

pending events.<br />

5/244<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Web server features<br />

The version of the Web server already available under RMOS3<br />

has been updated for use with RMOS3-TCP/IP V3.0. The Web<br />

server (V1.1) permits the display of HTML pages, uploading/<br />

downloading of files and access to the process data of user<br />

applications under RMOS3.<br />

Suitable library functions for exchanging data over the web<br />

server with RMOS3 applications are available to support this<br />

access.<br />

Advantages:<br />

With the aid of the Web server, the user obtains<br />

central access to distributed/remote automation solutions<br />

based on SIMATIC I<strong>PC</strong> with RMOS3<br />

the visualization of process data in a browser<br />

the operation of headless systems (e. g. for commissioning<br />

and maintenance purposes)<br />

For the remote maintenance of the SIMATIC I<strong>PC</strong>, the customer is<br />

given a Web server with HTML pages that can be adapted on an<br />

application-specific basis, into which the access to process tags<br />

can also be integrated.<br />

Application programming features<br />

For the application programming, plug-ins are again available<br />

for the Eclipse development environment (RMOS3-GNU V2.1 or<br />

higher):<br />

Online help:<br />

Integration of the socket function calls into the online help of<br />

the Eclipse-IDE for high-speed access to the function<br />

description.<br />

Code-completion:<br />

The extended code completion is also available for the socket<br />

functions and supports the developer when creating the<br />

source codes by completing the socket calls that are entered.<br />

Simulation:<br />

The simulation of socket calls maps RMOS socket calls to<br />

Windows socket calls and thus facilitates a rough pre-testing<br />

of the RMOS3 application while it is still on the development<br />

system.<br />

Prepared sample applications for RMOS3-GNU V2.1 or higher<br />

support the programmer when implementing the communication<br />

interface via the TCP protocol in blocking or non-blocking mode.<br />

For checking the node accessibility via Ethernet, a PINGexample<br />

is offered and can simply be integrated into the application.<br />

An application example is used for explaining the interface of the<br />

FTP function block library in order to implement an FTP client<br />

under RMOS3. Further examples describe the dispatch of<br />

e-mails via SMTP and the clock synchronization by means of<br />

NTP.


■ Function (continued)<br />

Characteristics of TCP diagnostics<br />

The following new supplementary programs are offered for the<br />

diagnosis of the TCP/IP stack:<br />

I<strong>PC</strong>ONF for output of the configuration of the Ethernet<br />

controller (IP address, subnetwork mask and standard<br />

gateway) integrated in the TCP/IP stack. This permits a quick<br />

overview of the current Ethernet configuration in the system.<br />

ARP for configuration of the address resolution protocol (ARP)<br />

table of the TCP/IP stacks : Display of all communication<br />

partners that have already communicated with the local<br />

system. This enables, for example, duplicated IP addresses to<br />

be detected.<br />

Further TCP utilities<br />

TCP utilities such as FTP, FTPD, TELNET and TELNETD permit<br />

the exchange of files and the remote maintenance of the<br />

RMOS3 system via the LAN interface. Additional programs<br />

ensure accessibility via gateways/routers (e. g. the ROUTECFG<br />

program) and are used for the quick testing of the connection<br />

(PING).<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

RMOS3 real-time operating system<br />

■ Technical specifications<br />

RMOS3-TCP/IP V3.0<br />

System requirements for the development system<br />

<strong>PC</strong> with Windows XP, Windows Vista or Windows 7<br />

Required software components:<br />

RMOS3 development environment from RMOS3 V3.40<br />

RMOS3-GNU as of V2.1, compiler and development interface<br />

Board support packages (optional, module-specific<br />

expansion packages)<br />

System requirements for target system<br />

SIMATIC Microbox <strong>PC</strong> 427B/ I<strong>PC</strong>427C<br />

SIMATIC Box <strong>PC</strong> 627B/I<strong>PC</strong>627C<br />

SIMATIC Box <strong>PC</strong> 827B<br />

SIMATIC Rack <strong>PC</strong> 647B/I<strong>PC</strong>647C<br />

SIMATIC Rack <strong>PC</strong> 847B/I<strong>PC</strong>847C<br />

Required software components:<br />

RMOS3 V3.40 or higher runtime environment (RMOS nucleus<br />

and service programs)<br />

Board support packages (optional, module-specific drivers)<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/245<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

RMOS3 real-time operating system<br />

RMOS3-TCP/IP V3.0<br />

■ Ordering data Order No. Order No.<br />

SICOMP RMOS3-TCP/<br />

IP V3.0 EL<br />

Development package, single<br />

license, TCP/IP software for<br />

RMOS3 V3.40 or higher,<br />

CD-ROM, including description in<br />

German in PDF format<br />

B 6AR1 403-0AN00-1BA0<br />

SICOMP RMOS3-TCP/IP V3.0<br />

EL, update from V2.3 to V3.0<br />

Development package, single<br />

license, TCP/IP software for<br />

RMOS3 V3.40 or higher,<br />

CD-ROM, including description in<br />

German in PDF format<br />

B 6AR1 403-0AN50-1BA0<br />

SICOMP RMOS3-TCP/IP V3.x<br />

Runtime license<br />

Runtime license for TCP/IP<br />

software V3.0 or higher for use<br />

with RMOS3 V3.40 or higher<br />

Accessories<br />

B 6AR1 403-0BN3<br />

SICOMP RMOS3 V3.50 EL<br />

Development package, single<br />

license, CD-ROM, including<br />

description in German in PDF<br />

format<br />

B 6AR1 405-0EA00-1AA4<br />

SICOMP RMOS3 V3.50<br />

EL update<br />

Update V3.40 to V3.50, development<br />

package, single license,<br />

runtime license, CD-ROM,<br />

including description in German<br />

in PDF format<br />

B 6AR1 405-0EA50-1AA4<br />

SICOMP RMOS3 V3.50 RT<br />

Runtime license for SICOMP<br />

RMOS3 operating system V3.50<br />

B 6AR1 403-0DA3<br />

SICOMP RMOS3-GNU V3.0 EL<br />

Development package, single<br />

license, CD-ROM, including<br />

description in German in PDF<br />

format<br />

B 6AR1 405-0BA00-1CA0<br />

SICOMP RMOS3-GNU V3.0<br />

EL update<br />

Update V2.x to V3.0, development<br />

package, single license,<br />

CD-ROM, including description in<br />

German in PDF format<br />

B 6AR1 405-0BA50-1CA0<br />

5/246<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

RMOS3-GRAPHX V1.0 EL<br />

Master license for graphic library<br />

for the creation of windoworiented<br />

interfaces of RMOS3<br />

Version 3.30 and higher<br />

D 6AR1 403-0BG00-1AA0<br />

BSP-SIMATIC I<strong>PC</strong> V3.1 EL<br />

Board Support Package for<br />

SIMATIC Microbox <strong>PC</strong> 427B,<br />

I<strong>PC</strong>427C, Box <strong>PC</strong> 627B,<br />

I<strong>PC</strong>627C, Box <strong>PC</strong> 827B, Rack <strong>PC</strong><br />

647B, I<strong>PC</strong>647C, Rack <strong>PC</strong> 847B,<br />

I<strong>PC</strong>847C for use under the<br />

SICOMP RMOS3 operating<br />

system V3.40 and higher, development<br />

package, single license,<br />

runtime license, CD-ROM, incl.<br />

description in German in PDF<br />

format, runtime license RMOS3<br />

V3.40 and higher not included.<br />

D 6AR1 403-0BC00-1CA1<br />

BSP-SIMATIC I<strong>PC</strong> V3.1<br />

EL Update<br />

Update from BSP-SIMATIC I<strong>PC</strong><br />

V3.0 to BSP-SIMATIC I<strong>PC</strong> V3.1.<br />

D 6AR1 403-0BC50-1CA1<br />

BSP SIMATIC I<strong>PC</strong> V3.x RT<br />

Runtime license for Board<br />

Support Package for<br />

SIMATIC Microbox <strong>PC</strong> 427B,<br />

I<strong>PC</strong>427C<br />

SIMATIC Box <strong>PC</strong> 627B, I<strong>PC</strong>627C,<br />

SIMATIC Box <strong>PC</strong> 827B,<br />

SIMATIC Rack <strong>PC</strong> 647B,<br />

I<strong>PC</strong>647C, SIMATIC Rack <strong>PC</strong><br />

847B, I<strong>PC</strong>847C for use under the<br />

operating system SICOMP<br />

RMOS3, V3.40 and higher.<br />

Runtime license RMOS3, V3.40<br />

and higher not included.<br />

D 6AR1 403-0CC3<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992


■ Overview<br />

RMOS3-GRAPHX V1.0 provides you with a comprehensive<br />

graphic package which enables you to expand your C/C++<br />

based automation solution under SICOMP RMOS3 with a userfriendly<br />

graphic interface for operator control and monitoring.<br />

Use of the Qt-based graphic library of the Norwegian company<br />

Trolltech-Nokia (www.gt.nokia.com) allows window-based inter-<br />

■ Benefits<br />

Reduction of hardware costs thanks to visualization and<br />

controlling on a single <strong>PC</strong><br />

Reduction of engineering costs through a wide range of<br />

prefabricated control and display elements and existing<br />

Qt-based graphic interfaces that can be re-used.<br />

■ Application<br />

RMOS3 stands for industrial capability when being used as<br />

embedded operating system and enables extremely high<br />

response times with open-loop and closed-loop control tasks.<br />

■ Design<br />

RMOS3-GRAPHX contains all the necessary libraries and development<br />

programs (Qt tool for Cygwin) to implement customerspecific,<br />

window-oriented graphical user interfaces with the<br />

development environment RMOS3-GNU and the Qt Designer<br />

from Trolltech-Nokia. Since numerous prefabricated control and<br />

Qt V4.1 2)<br />

(Qt Desktop Light Edition<br />

One Platform (Windows))<br />

Windows XP / Windows Vista / Windows 7<br />

Development system<br />

For RMOS3-GNU V3.0 or higher, an update for<br />

RMOS3-GraphX V1.1 is offered via Customer Support:<br />

www.siemens.com/automation/support-request.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

RMOS3 development environment<br />

RMOS3-GRAPHX V1.0<br />

Documentation<br />

Eclipse IDE plug-in for RMOS3-GRAPHX<br />

Qt tools for Cygwin:<br />

Qmake, moc, rcc, uic<br />

RMOS3 libraries (GNU):<br />

LIBRMQTOSG.A<br />

LIBRMQTFBG.A<br />

LIBQTCORE.A<br />

LIBQTGUI.A<br />

RMOS3-GRAPHX<br />

Application example (GNU)<br />

RMOS3-GNU V2.1 or higher<br />

<strong>PC</strong>-based Automation<br />

RMOS3 real-time operating system<br />

RMOS3-GRAPHX V1.0<br />

faces to be created with a "look and feel" and input facilities<br />

comparable to Windows. Real-time characteristics are<br />

maintained within the multi-tasking RMOS3 operating system<br />

environment.<br />

In combination with the widely used development tools GNU,<br />

Eclipse and the QT Designer from Trolltech-Nokia, convenient<br />

development tools are available to you for creating your real-time<br />

applications on approved SIMATIC I<strong>PC</strong> hardware.<br />

No training costs for operating staff necessary; same "look<br />

and feel" as under Windows<br />

The RMOS3-GRAPHX V1.0 graphic package is used for the<br />

design of graphic interfaces for RMOS3. It eliminates the need<br />

for a second <strong>PC</strong> for visualization since both operator inputs and<br />

control tasks can be carried out on the automation computer.<br />

display elements are available, as generally known under<br />

Windows, the development time can be reduced to a minimum.<br />

Scope of delivery of RMOS3-GRAPHX V1.0<br />

Not included in scope of delivery<br />

1) Incl. software fix RMOS3 V3.30.04<br />

2) Trolltech - Nokia product<br />

RMOS3 runtime environment<br />

RMOS3-GRAPHX V1.0<br />

Fonts<br />

USB stack<br />

RMOS3 V3.30 1) or higher<br />

Target system: SIMATIC I<strong>PC</strong><br />

For creating the graphic interface the "Qt Designer" from<br />

Trolltech-Nokia is required. This is an integrated part of the<br />

"Qt Desktop Light Edition" product for Windows and can be<br />

purchased directly from Trolltech-Nokia (www.gt.nokia.com).<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00483<br />

5/247<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

RMOS3 real-time operating system<br />

RMOS3-GRAPHX V1.0<br />

■ Function<br />

User and service friendliness<br />

Same API (Application Programming Interface) as for desktop<br />

version Qt V4.1 for Windows, Unix, Linux, Mac OS X and<br />

embedded Linux<br />

Comprehensive function library for embedding prefabricated<br />

control elements, such as text browsers, tables, menus<br />

Integration of graphic interface as a task in the multitasking<br />

environment of RMOS3 to increase the reusability of existing<br />

applications<br />

Use of the standard software Qt Designer from Trolltech-Nokia<br />

RMOS3-GraphX plug-in into the Eclipse development<br />

environment for efficient creation of graphic interfaces<br />

Industrial compatibility<br />

No negative effect on response times and deterministic<br />

response thanks to real-time graphics library<br />

5/248<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Technical specifications<br />

System requirements for the development system<br />

<strong>PC</strong> with Windows XP, Windows Vista or Windows 7<br />

Required software components:<br />

RMOS3 development enviroment RMOS3 V3.40 or higher or<br />

RMOS3 V3.30 including software fix RMOS3 V3.30.04<br />

RMOS3-GNU from V2.1, compiler and development interface<br />

For RMOS3-GNU V3.0 or higher, an update for<br />

RMOS3-GraphX V1.1 is offered via Customer Support:<br />

www.siemens.com/automation/support-request<br />

RMOS3-GRAPHX V1.0, graphic package for creation of<br />

graphic interfaces for RMOS3<br />

Update RMOS3-GraphX V1.1 in connection with RMOS3-GNU<br />

V3.0 or higher is available via Customer Support:<br />

www.siemens.com/automation/support-request<br />

Qt Desktop Light Edition for Windows from Trolltech-Nokia<br />

(www.gt.nokia.com)<br />

Optional:<br />

Board support packages (optional, module-specific<br />

expansion packages)<br />

System requirements for target system<br />

SIMATIC I<strong>PC</strong><br />

Required software components:<br />

RMOS3 V3.40 or higher runtime environment (RMOS nucleus<br />

and service programs)<br />

RMOS3-GRAPHX V1.0 runtime license (graphics support,<br />

USB driver)<br />

Optional:<br />

Board support packages (optional, module-specific drivers)


© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

RMOS3 real-time operating system<br />

RMOS3-GRAPHX V1.0<br />

■ Ordering data Order No. Order No.<br />

RMOS3-GRAPHX V1.0 EL D 6AR1403-0BG00-1AA0<br />

BSP-SIMATIC I<strong>PC</strong> V3.1 EL D 6AR1 403-0BC00-1CA1<br />

Master license for graphics library<br />

for creation of window-oriented<br />

interfaces of RMOS3 Version 3.30<br />

and higher<br />

Board Support Package for<br />

SIMATIC Microbox <strong>PC</strong> 427B,<br />

I<strong>PC</strong>427C, Box <strong>PC</strong> 627B,<br />

I<strong>PC</strong>627C, Box <strong>PC</strong> 827B, Rack <strong>PC</strong><br />

Qt Desktop Light Edition,<br />

obtainable from Trolltech-Nokia, 647B, I<strong>PC</strong>647C, Rack <strong>PC</strong> 847B,<br />

Single Platform Windows<br />

www.gt.nokia.com<br />

I<strong>PC</strong>847C for use under the<br />

development package<br />

SICOMP RMOS3 operating<br />

Qt Desktop Light Edition V4.1.4<br />

for Windows, incl. Qt Designer<br />

system V3.40 and higher, development<br />

package, single license,<br />

runtime license, CD-ROM, incl.<br />

Accessories<br />

description in German in PDF<br />

SICOMP RMOS3 V3.50 EL B 6AR1 405-0EA00-1AA4<br />

format, runtime license RMOS3<br />

V3.40 and higher not included.<br />

Development package, single<br />

license, CD-ROM, including<br />

description in German in PDF<br />

BSP-SIMATIC I<strong>PC</strong> V3.1 EL<br />

Update<br />

D 6AR1403-0BC50-1CA1<br />

format<br />

Update from BSP-SIMATIC I<strong>PC</strong><br />

SICOMP RMOS3 V3.50 EL B 6AR1 405-0EA50-1AA4<br />

V3.0 to BSP-SIMATIC I<strong>PC</strong> V3.1.<br />

update<br />

BSP SIMATIC I<strong>PC</strong> V3.x RT D 6AR1403-0CC3<br />

Update V3.40 to V3.50, devel-<br />

Runtime license for Board<br />

opment package, single license,<br />

Support Package for<br />

runtime license, CD-ROM,<br />

SIMATIC Microbox <strong>PC</strong> 427B,<br />

including description in German<br />

I<strong>PC</strong>427C<br />

in PDF format<br />

SIMATIC Box <strong>PC</strong> 627B, I<strong>PC</strong>627C,<br />

SICOMP RMOS3 V3.50 RT B 6AR1 403-0DA3<br />

SIMATIC Box <strong>PC</strong> 827B,<br />

SIMATIC Rack <strong>PC</strong> 647B,<br />

Runtime license for SICOMP<br />

I<strong>PC</strong>647C, SIMATIC Rack <strong>PC</strong><br />

RMOS3 operating system V3.50<br />

847B, I<strong>PC</strong>847C for use under the<br />

SICOMP RMOS3-GNU V3.0 EL B 6AR1 405-0BA00-1CA0<br />

operating system SICOMP<br />

RMOS3, V3.40 and higher.<br />

Single license for the GNU development<br />

tools incl. compiler, linker,<br />

debugger and Eclipse IDE,<br />

special RMOS3 libraries for<br />

creating applications, project<br />

examples and documentation<br />

Runtime license RMOS3, V3.40<br />

and higher not included.<br />

SICOMP RMOS3-GNU V3.0 EL<br />

update<br />

Update V2.x to V3.0, development<br />

package, single license,<br />

CD-ROM, including description in<br />

German in PDF format<br />

B 6AR1 405-0BA50-1CA0<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/249<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

RMOS3 real-time operating system<br />

BSP SIMATIC I<strong>PC</strong> V3.1 for RMOS3<br />

■ Overview<br />

The BSP SIMATIC I<strong>PC</strong> V3.1 now also supports the SIMATIC I<strong>PC</strong>s<br />

of the C generation. The SIMATIC I<strong>PC</strong>627C, I<strong>PC</strong>647C and<br />

I<strong>PC</strong>847C are new additions. In addition to a new Gigabit<br />

Ethernet driver and a new USB 2.0 stack, up to 4 processor<br />

cores can be used in symmetrical multiprocessing mode.<br />

Furthermore, the PROFINET onboard functionalities, PROFIBUS,<br />

CAN, and hardware-level functions are available on the<br />

SIMATIC I<strong>PC</strong> under the real-time operating system RMOS3<br />

V3.40 and higher. For creating applications with the PROFINET,<br />

PROFIBUS, CAN and hardware-level functions, an online help<br />

and code completion is offered for the Eclipse development<br />

environment (RMOS3-GNU V2.1 or higher).<br />

The BSP SIMATIC I<strong>PC</strong> V3.1 now supports the following rugged<br />

SIMATIC <strong>PC</strong>s and SIMATIC I<strong>PC</strong>s provided with long-term availability:<br />

Microbox <strong>PC</strong> 427B and I<strong>PC</strong>427C<br />

Box <strong>PC</strong> 627B and I<strong>PC</strong>627C<br />

Box <strong>PC</strong> 827B<br />

Rack 647B and I<strong>PC</strong>647C<br />

Rack <strong>PC</strong> 847B and I<strong>PC</strong>847C<br />

The BSP SIMATIC I<strong>PC</strong> V3.1 replaces the existing BSP<br />

SIMATIC I<strong>PC</strong> V3.0 Board Support Package. An upgrade to BSP<br />

SIMATIC I<strong>PC</strong> V3.1 is available.<br />

5/250<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Industry-standard<br />

PROFINET onboard for the high-performance, cyclic and<br />

isochronous transmission of user data via Industrial Ethernet<br />

Detailed monitoring functions (battery, temperature, fan,<br />

watchdog, and S.M.A.R.T.) to avoid system downtimes<br />

Configurable transmission rates and modes on the Gigabit-<br />

Ethernet interface for optimum integration into the<br />

communication network<br />

Flexible<br />

RMOS3 nucleus can be flexibly adapted to the requirements<br />

of the automation solution<br />

Optimally matched to SIMATIC <strong>PC</strong> and SIMATIC I<strong>PC</strong><br />

User-friendly<br />

Effective programming through integration of the PROFINET,<br />

PROFIBUS, CAN and monitoring functions into the code<br />

completion and online help of the GNU development<br />

environment Eclipse<br />

Drastic reduction in commissioning times through<br />

configurable nucleus<br />

Complete package incl. PROFINET, PROFIBUS, USB,<br />

Ethernet and CAN drivers<br />

100% downward compatible operating system versions<br />

Free support<br />

No additional software downloads necessary<br />

■ Application<br />

The Board Support Package BSP-SIMATIC I<strong>PC</strong> V3.1 for RMOS3<br />

supports application programmers during the implementation of<br />

real-time applications, e.g. for control of printing machines, chip<br />

handlers and test setups. Through the provision of all drivers for<br />

the onboard interfaces of the SIMATIC I<strong>PC</strong>s (Ethernet, USB,<br />

PROFINET, PROFIBUS, CAN) and the programming interfaces<br />

required for PROFINET, PROFIBUS, BasisCAN and hardware<br />

functions, the SIMATIC I<strong>PC</strong>s can be optimally integrated into the<br />

control infrastructure.


■ Design<br />

The configurable nucleus has been expanded for support of the<br />

new SIMATIC I<strong>PC</strong>s of the C generation and downloads, as far as<br />

necessary, the drivers for the onboard interfaces USB 2.0,<br />

Gigabit Ethernet, PROFINET IO, PROFIBUS DP, CAN bus, and<br />

diagnostics drivers for hardware-level functions.<br />

The PROFINET onboard interfaces of the SIMATIC I<strong>PC</strong>s offer<br />

diverse options for the integration of real-time solutions with<br />

SIMATIC I<strong>PC</strong> into PROFINET networks. PROFINET RT<br />

(Real-Time) and PROFINET IRT (Isochronous Real-Time) are<br />

supported in the operating modes IRT with high flexibility or IRT<br />

with high performance with cycle times up to 250 µs and jitter<br />

accuracy


5<br />

<strong>PC</strong>-based Automation<br />

RMOS3 real-time operating system<br />

BSP SIMATIC I<strong>PC</strong> V3.1 for RMOS3<br />

■ Function<br />

All necessary interface drivers are already included<br />

in the BSP<br />

Complete package incl. USB, Ethernet, PROFINET,<br />

PROFIBUS, CAN, and hardware diagnostic drivers<br />

The SIMATIC I<strong>PC</strong> is ready to use as soon as the RMOS3<br />

runtime environment has been installed<br />

No additional software downloads necessary<br />

Configurable nucleus<br />

Immediately executable RMOS3 nucleus in which all static<br />

and dynamic driver interfaces as well as a number of other<br />

hardware options are supported and diagnostic functions are<br />

integrated. The settings required for the target hardware are<br />

implemented exclusively by means of the RMOS.INI<br />

configuration file. The user no longer has to generate the<br />

RMOS nucleus.<br />

Support of specific properties of the SIMATIC I<strong>PC</strong>s<br />

- Storage media recognition up to 4 GB RAM<br />

- Up to 2 MB battery-backed SRAM for retentive data<br />

(as independent drive or for direct access)<br />

- Temperature monitoring function for the processor, power<br />

supply, enclosure, and memory<br />

- Fan monitoring function for enclosure fan, power supply fan,<br />

hard disk fan<br />

- Battery monitoring function<br />

- Support of up to 2 CompactFlash cards<br />

- Determination of S.M.A.R.T. status information of the hard<br />

disk, the solid-state drive or the SIMATIC CF card<br />

- 7-segment display<br />

-User LEDs<br />

- Implementation of an operating hours counter for monitoring<br />

the service intervals of the SIMATIC I<strong>PC</strong>s<br />

RMOS3 nucleus maintained and system-tested by <strong>Siemens</strong><br />

No need for familiarization with generating the nucleus, so<br />

development can be started sooner<br />

Uniform user interfaces extending beyond the CPU platforms<br />

for greater ease of use compared to the standard nucleus<br />

USB interface<br />

Support for USB memory sticks, USB keyboards, USB hubs<br />

and USB mice, now also with USB 2.0<br />

Ethernet interface<br />

Support for all 10/100/1000 Mbit/s Ethernet interfaces of the<br />

SIMATIC I<strong>PC</strong>s<br />

Configurable transmission modes of the Gigabit LAN driver<br />

(autonegotiate / full-duplex / half-duplex)<br />

Transmission rate of the Gigabit LAN driver can be set<br />

(10, 100 or 1000 Mbit/s)<br />

Ethernet driver with connectable filter functionality: Filtering of<br />

all network packages that load the system; only ARP, ICMP,<br />

TCP packages and optional UDP packages are accepted<br />

5/252<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

PROFINET interface<br />

Operation of the SIMATIC I<strong>PC</strong> as PROFINET IO Controller or<br />

PROFINET IO Device via the PROFINET onboard interface or<br />

an SIMATIC NET CP16xx add-on card<br />

Support for real-time communication (RT) and isochronous<br />

real-time communication (IRT) in the operating modes IRT with<br />

high performance and IRT with high flexibility<br />

Access functions are compatible with the PROFINET functions<br />

described in the "Programming Manual SIMATIC NET IO-Base<br />

User Programming Interface".<br />

The PROFINET IO functions are provided for RMOS3 in the<br />

form of a GNU library<br />

As a matter of principle, the SIMATIC I<strong>PC</strong>s are configured for<br />

PROFINET using the NCM <strong>PC</strong> configuration software from<br />

Version V5.4 SP4 or <strong>ST</strong>EP7 from Version 5.4 SP4 (neither<br />

included in the scope of supply of the BSP SIMATIC I<strong>PC</strong> V3.1)<br />

The RMOS3 PROFINET IO stack is released for the PROFINET<br />

onboard interfaces of the SIMATIC I<strong>PC</strong> or the SIMATIC NET<br />

CP16xx with the firmware of version 2.3.2 or version V2.3.1.<br />

The firmware versions 2.3.1 and 2.3.2 are included in the<br />

scope of supply of the BSP SIMATIC I<strong>PC</strong> V3.1<br />

PROFIBUS interface<br />

Operation of the SIMATIC I<strong>PC</strong>s in the modes of master, slave<br />

and combination (parallel operation as master and slave)<br />

including diagnostics<br />

User programming interface for GNU<br />

Transmission rate 9.6 kbps to 12 Mbps<br />

Configuring software for PROFIBUS (not included in BSP):<br />

COM PROFIBUS or <strong>ST</strong>EP7 (when SIMATIC I<strong>PC</strong> is used as a<br />

slave, operated on a master configured using <strong>ST</strong>EP7)<br />

Interrupts, master Class 2, S7 functions, FDL as well as DPV1<br />

and DPV2 are not supported<br />

CAN bus interface<br />

Operation of the Microbox <strong>PC</strong> 427B and I<strong>PC</strong> 427C with<br />

BasicCAN interface<br />

User programming interface for GNU


© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

RMOS3 real-time operating system<br />

BSP SIMATIC I<strong>PC</strong> V3.1 for RMOS3<br />

■ Function (continued)<br />

■ Technical specifications<br />

Hardware-based functions, diagnostic functions and<br />

System requirements for the development system<br />

monitoring functions<br />

<strong>PC</strong> with Windows XP, Windows Vista or Windows 7<br />

Interrupt sharing on the <strong>PC</strong>I bus is generally activated for<br />

reliable connection of <strong>PC</strong>I cards<br />

Required software components:<br />

Extended temperature monitoring function for targeted<br />

RMOS3 development environment as of RMOS3 V3.40<br />

intervention in the automation process when a specified limit RMOS3-GNU as of V2.1, compiler and development interface<br />

temperature is exceeded. The temperature of the CPU, the<br />

power supply, the enclosure, the memory, and the main board<br />

Board support packages (optional, module-specific<br />

can be determined depending on the sensors supported by<br />

expansion packages)<br />

the SIMATIC I<strong>PC</strong>s.<br />

System requirements for target system<br />

Fan monitoring function (Box <strong>PC</strong> 627B, Box <strong>PC</strong> 827B, Rack <strong>PC</strong> SIMATIC Microbox <strong>PC</strong> 427B/ I<strong>PC</strong>427C<br />

647B, Rack <strong>PC</strong> 847B, I<strong>PC</strong>627C, I<strong>PC</strong>647C and I<strong>PC</strong>847C) for<br />

checking the speed of the enclosure fans (front and back), the<br />

SIMATIC Box <strong>PC</strong> 627B and I<strong>PC</strong>627C<br />

power supply fans, and the hard disk fans. If the speed is too SIMATIC Box <strong>PC</strong> 827B<br />

low, targeted intervention in the automation process is<br />

SIMATIC Rack 647B and I<strong>PC</strong>647C<br />

possible and the "FAN" LED (Rack <strong>PC</strong> 847B, Rack <strong>PC</strong> 647B,<br />

I<strong>PC</strong>647C and I<strong>PC</strong>847C) can be lit.<br />

SIMATIC Rack <strong>PC</strong> 847B and I<strong>PC</strong>847C<br />

Battery monitoring function (Microbox <strong>PC</strong> 427B, Box <strong>PC</strong> 627B, Required software components:<br />

Box <strong>PC</strong> 827B, Rack <strong>PC</strong> 647B, Rack <strong>PC</strong> 847B, I<strong>PC</strong>427C,<br />

RMOS3 V3.40 or higher runtime environment (RMOS nucleus<br />

I<strong>PC</strong>627C, I<strong>PC</strong>647C and I<strong>PC</strong>847C) for checking the charging and service programs)<br />

condition of the CMOS battery and signaling when<br />

Board support packages (optional, module-specific drivers)<br />

replacement is necessary<br />

Watchdog function (Microbox <strong>PC</strong> 427B, Box <strong>PC</strong> 627B,<br />

Box <strong>PC</strong> 827B, Rack <strong>PC</strong> 647B, Rack <strong>PC</strong> 847B, I<strong>PC</strong>427C,<br />

I<strong>PC</strong>627C, I<strong>PC</strong>647C and I<strong>PC</strong>847C) for detecting program<br />

crashes<br />

Interface to user LEDs from multiple CPUs (Rack <strong>PC</strong> 647B,<br />

Rack <strong>PC</strong> 847B, I<strong>PC</strong>647C and I<strong>PC</strong>847C: 3x red, Box <strong>PC</strong> 627B,<br />

Box <strong>PC</strong> 827B and I<strong>PC</strong>627C: 2x red/green, Microbox <strong>PC</strong> 427B<br />

and I<strong>PC</strong>427C: 1x yellow/red and 1x yellow/green) for the<br />

visualization of status signals<br />

Access to 2-digit, 7-segment display (Box <strong>PC</strong> 627B,<br />

Box <strong>PC</strong> 827B, I<strong>PC</strong>627C) for power-up display and outputs<br />

from applications for diagnostic purposes<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/253<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

RMOS3 real-time operating system<br />

BSP SIMATIC I<strong>PC</strong> V3.1 for RMOS3<br />

■ Ordering data Order No. Order No.<br />

BSP-SIMATIC I<strong>PC</strong> V3.1 EL D 6AR1 403-0BC00-1CA1<br />

Accessories<br />

Board Support Package for<br />

SICOMP RMOS3 V3.50 EL B 6AR1 405-0EA00-1AA4<br />

SIMATIC Microbox <strong>PC</strong> 427B,<br />

I<strong>PC</strong>427C, Box <strong>PC</strong> 627B,<br />

I<strong>PC</strong>627C, Box <strong>PC</strong> 827B,<br />

Rack <strong>PC</strong> 647B, I<strong>PC</strong>647C,<br />

Rack <strong>PC</strong> 847B, I<strong>PC</strong>847C for use<br />

Development package, single<br />

license, CD-ROM, including<br />

description in German in PDF<br />

format<br />

under the SICOMP RMOS3<br />

operating system V3.40 and<br />

higher, development package,<br />

single license, runtime license,<br />

CD-ROM, incl. description in<br />

German in PDF format, runtime<br />

license RMOS3 V3.40 and higher<br />

not included.<br />

SICOMP RMOS3 V3.50 EL B<br />

update<br />

Update V3.40 to V3.50, development<br />

package, single license,<br />

runtime license, CD-ROM,<br />

including description in German<br />

in PDF format<br />

6AR1 405-0EA50-1AA4<br />

BSP-SIMATIC I<strong>PC</strong> V3.1 EL D 6AR1403-0BC50-1CA1<br />

SICOMP RMOS3 V3.50 RT B 6AR1 403-0DA3<br />

Update<br />

Runtime license for SICOMP<br />

Update from BSP-SIMATIC I<strong>PC</strong><br />

RMOS3 operating system V3.50<br />

V3.0 to BSP-SIMATIC I<strong>PC</strong> V3.1.<br />

SICOMP RMOS3-GNU V3.0 EL B 6AR1 405-0BA00-1CA0<br />

BSP SIMATIC I<strong>PC</strong> V3.x RT D 6AR1403-0CC3<br />

Development package, single<br />

Runtime license for Board<br />

Support Package for<br />

SIMATIC Microbox <strong>PC</strong> 427B,<br />

license, CD-ROM, including<br />

description in German in PDF<br />

format<br />

I<strong>PC</strong>427C<br />

SIMATIC Box <strong>PC</strong> 627B, I<strong>PC</strong>627C,<br />

SIMATIC Box <strong>PC</strong> 827B,<br />

SIMATIC Rack <strong>PC</strong> 647B,<br />

I<strong>PC</strong>647C, SIMATIC Rack <strong>PC</strong><br />

847B, I<strong>PC</strong>847C for use under the<br />

operating system SICOMP<br />

SICOMP RMOS3-GNU V3.0 EL B<br />

update<br />

Update V2.x to V3.0, development<br />

package, single license,<br />

CD-ROM, including description in<br />

German in PDF format<br />

6AR1 405-0BA50-1CA0<br />

RMOS3, V3.40 and higher.<br />

Runtime license RMOS3, V3.40<br />

and higher not included.<br />

SICOMP RMOS3-TCP/IP<br />

V3.0 EL<br />

Development package, single<br />

license, TCP/IP software for<br />

RMOS3 V3.40 or higher,<br />

CD-ROM, including description in<br />

German in PDF format<br />

B 6AR1 403-0AN00-1BA0<br />

SICOMP RMOS3-TCP/IP V3.0<br />

EL, update from V2.3 to V3.0<br />

Development package, single<br />

license, TCP/IP software for<br />

RMOS3 V3.40 or higher,<br />

CD-ROM, including description in<br />

German in PDF format<br />

B 6AR1 403-0AN50-1BA0<br />

SICOMP RMOS3-TCP/IP V3.x<br />

Runtime license<br />

Runtime license for TCP/IP<br />

software V3.0 or higher for use<br />

with RMOS3 V3.40 or higher<br />

B 6AR1 403-0BN3<br />

RMOS3-GRAPHX V1.0 EL<br />

Master license for graphic library<br />

for the creation of windoworiented<br />

interfaces of RMOS3<br />

Version 3.30 and higher<br />

D 6AR1403-0BG00-1AA0<br />

5/254<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

D: Subject to export regulations: AL: N and ECCN: 5D992


■ Overview<br />

SIMATIC <strong>PC</strong>s offer users a wide range of designs and systems<br />

which perfectly match industrial applications and fulfill the high<br />

requirements in terms of ruggedness.<br />

These include e. g.:<br />

Wide temperature of use up to 55 °C<br />

High resistance to vibration/shock<br />

Rugged housing design<br />

Special degrees of protection up to IP65, NEMA 4<br />

High electromagnetic compatibility (EMC)<br />

UL, CE industry certification<br />

Integrated industrial power supplies (NAMUR)<br />

Easy-to-service design for rapid replacement of faulty<br />

components<br />

Increased system availability<br />

A graded concept is available for effective early detection of<br />

potential failures and minimization of actual downtimes. This<br />

consists of hardware and software expansion options specially<br />

developed for SIMATIC <strong>PC</strong>s with which the system availability<br />

can be individually increased depending on the safety requirements.<br />

The use pays off:<br />

Because the safety is significantly increased by components<br />

such as a second hard disk for additional data backup or the<br />

DiagMonitor for permanent self-diagnostics. The system availability<br />

options thus make a contribution to the significant minimization<br />

of the total costs (TCO) of the installation according to the<br />

motto: "Small effort, large effect".<br />

The following components are available:<br />

Hard disks options<br />

Solid state drive (SSD)<br />

Second hard disk:<br />

The safety of the data stored on the hard disk is a cornerstone<br />

for system availability.<br />

- Simple and fast data backup of complete installation and<br />

user data in combination with the SIMATIC I<strong>PC</strong> Image<br />

Creator.<br />

- Following a faulty software installation or in the case of a hard<br />

disk defect, the system can be immediately put back into<br />

operation by booting the back-up disk.<br />

- Fast download of the last saved hard disk image to the<br />

working disk.<br />

Two hard disks are optionally available in a user-friendly swap<br />

frame for the Rack <strong>PC</strong> to permit fast and easy data backup.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

Expansion components/accessories<br />

SIMATIC I<strong>PC</strong> CompactFlash<br />

The application of <strong>PC</strong>s in industrial areas requires rugged<br />

systems to prevent or minimize production downtimes.<br />

SIMATIC I<strong>PC</strong>s have been developed precisely for this purpose.<br />

One way of improving the industrial suitability and system availability<br />

of SIMATIC I<strong>PC</strong>s even further is to use SIMATIC <strong>PC</strong><br />

CompactFlash cards instead of hard disk drives. These are<br />

system-tested with SIMATIC I<strong>PC</strong>s.<br />

SIMATIC <strong>PC</strong> CompactFlash is a hardware option that can be<br />

ordered via the relevant SIMATIC I<strong>PC</strong> configurator or separately<br />

as an accessory.<br />

SIMATIC I<strong>PC</strong> USB FlashDrive<br />

Mobile memory medium for SIMATIC I<strong>PC</strong>/PG<br />

Fast data transfer (USB 2.0) and high memory capacity<br />

Ultra-compact and rugged<br />

Pre-installed SIMATIC I<strong>PC</strong> BIOS Manager V3.1<br />

SIMATIC I<strong>PC</strong> Service USB FlashDrive<br />

The SIMATIC I<strong>PC</strong> Service USB FlashDrive is the ideal tool for<br />

maintenance as well as saving and restoring of data. With the<br />

pre-installed SIMATIC I<strong>PC</strong> Image & Partition Creator V3.1 and<br />

SIMATIC I<strong>PC</strong> BIOS Manager V3.1, the FlashDrive is immediately<br />

ready for use.<br />

SINUMERIK 3.5" floppy disk drive, USB 1.1<br />

The USB floppy disk drive is provided for fast exchange of user<br />

data (e. g. recipes) or files. The drive must not be used as a<br />

cyclic archiving drive. The front-panel installation and degree of<br />

protection IP54 permit data exchange from the front without<br />

opening the control cabinet door.<br />

Central I/O expansion <strong>PC</strong> IO<br />

The <strong>PC</strong> IO expansion comprises:<br />

basic module with encoder/counter functionality,<br />

<strong>PC</strong>I104 interface to the host system, and communication<br />

interfaces to the I/O modules<br />

digital and analog I/O modules that are managed by the basic<br />

module<br />

mechanical installation components.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/255<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

Expansion components/accessories<br />

■ Overview (continued)<br />

Industrial USB Hub 4<br />

The Industrial USB Hub 4 is essentially used as a USB hub for<br />

the connection of I/O devices to Multi Panels and Panel <strong>PC</strong>s<br />

with an integrated USB interface<br />

USB I/O devices can be connected to the panel and operated<br />

via the USB Hub 4 without opening the cabinet door<br />

The Industrial Hub 4, in contrast to commercially available<br />

USB hubs, can be used in harsh industrial environments<br />

(IP65)<br />

SIMATIC Panel <strong>PC</strong> Remote Kit<br />

Separation of computer unit and operator control unit<br />

At a maximum distance of up to 30 m<br />

Pure hardware solution, no need to install additional software<br />

Maintaining the full Panel <strong>PC</strong> front functionality<br />

SIMATIC I<strong>PC</strong> Image & Partition Creator<br />

Software tool for preventive data backup of hard disk contents<br />

High-speed restoring of system and data partitions with bit<br />

accuracy; user software and special installations are also<br />

backed up<br />

Software tool for editing the hard disk partitioning<br />

SIMATIC I<strong>PC</strong> DiagMonitor<br />

<strong>PC</strong> diagnostics/alarm software for early detection and<br />

diagnostics of <strong>PC</strong> problems<br />

Comprehensive monitoring of temperature, fans, hard disks<br />

(SMART, RAID, CF card, SSD), watchdog<br />

Operating hours counter for preventive maintenance<br />

Integrated log functions, comprehensive text messages,<br />

online help (English/German)<br />

5/256<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC I<strong>PC</strong> Remote Manager<br />

Efficient remote maintenance and management of<br />

SIMATIC I<strong>PC</strong>s.<br />

With the SIMATIC I<strong>PC</strong> Remote Manager you can use functions of<br />

the Intel Active Management Technology (Intel AMT) for<br />

SIMATIC I<strong>PC</strong>s. Intel AMT is used for remote management of <strong>PC</strong>s.<br />

SIMATIC I<strong>PC</strong> BIOS Manager<br />

The SIMATIC I<strong>PC</strong> BIOS Manager is a software tool with which<br />

CMOS data from the BIOS configuration of a SIMATIC I<strong>PC</strong> can<br />

be edited. The tool is obtained by downloading it from the<br />

Internet using the Automation Value Card from Customer<br />

Support.<br />

ADDM Data Management<br />

With ADDM, you are completely in control of the SIMATIC and<br />

SINUMERIK controllers – around the clock and with any program<br />

version. This tool, indispensable in modern production systems,<br />

allows user-friendly backup, comparison and management of<br />

control data.<br />

DC-UPS uninterruptible power supplies<br />

The uninterruptible DC power supply with battery modules<br />

consists of DC UPS modules.<br />

The maintenance-free SITOP UPS500 with capacitors as energy<br />

stores are especially suitable for use at high ambient temperatures.<br />

A further advantage of these high-capacity double-layer<br />

capacitors are their shorter charging times.<br />

For flexible use, there is the SITOP UPS500S - 15 A basic unit in<br />

2.5 kW and 5 kW versions. Up to 3 SITOP UPS501S expansion<br />

modules of 5 kW each can be connected in parallel to extend the<br />

backup times. The SITOP UPS500P IP65 version has capacitors<br />

for 5 or 10 kW and supplies up to 7 A output current.<br />

Input and output devices<br />

The SIMATIC I<strong>PC</strong> accessories encompass various input<br />

devices.


■ Overview<br />

Rugged systems are required when using <strong>PC</strong>s in industrial<br />

environments to minimize production standstill times.<br />

SIMATIC I<strong>PC</strong>s are specially designed for this purpose. One<br />

possibility for enhancing the industrial compatibility and system<br />

availability of the SIMATIC I<strong>PC</strong> is to use SIMATIC I<strong>PC</strong> Compact-<br />

Flash instead of hard disk drives. These have been systemtested<br />

with the respective SIMATIC I<strong>PC</strong>.<br />

SIMATIC I<strong>PC</strong> CompactFlash can be ordered as a hardware<br />

option through SIMATIC I<strong>PC</strong> Configurator or as an accessory.<br />

Depending on the application, cards are available with a storage<br />

capacity of 256 MB and 2 to 8 GB.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

■ Benefits<br />

SIMATIC I<strong>PC</strong> CompactFlash<br />

Reduced costs through high industrial functionality<br />

High system availability because no mechanical parts subject<br />

to wear are used<br />

High degree of industrial compatibility because of high<br />

resistance to vibration/shock and high temperatures<br />

Minimization of time and effort for customer through<br />

qualification and system test by SIMATIC I<strong>PC</strong><br />

Integrating the CompactFlash diagnosis has enabled a further<br />

increase in system availability<br />

■ Ordering data<br />

SIMATIC I<strong>PC</strong> CompactFlash<br />

Order No.<br />

256 MB A 6ES7 648-2BF02-0XC0<br />

2GB A 6ES7 648-2BF02-0XF0<br />

4GB A 6ES7 648-2BF02-0XG0<br />

8GB A 6ES7 648-2BF02-0XH0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/257<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

SIMATIC I<strong>PC</strong> (Service) USB FlashDrive<br />

■ Overview<br />

■ Benefits<br />

Ultra-compact, rugged and industry-standard<br />

SLC-Flash technology for maximum data security and<br />

performance<br />

High level of electromagnetic compatibility according to<br />

CE Industry when operated with SIMATIC I<strong>PC</strong><br />

Especially suitable for use in industrial environments thanks to<br />

the metal enclosure<br />

Two USB FlashDrives can be inserted one above the other/<br />

side by side<br />

High degree of investment protection<br />

System tested with SIMATIC I<strong>PC</strong>/PG (hardware and software)<br />

Can be used to transfer Automation License Keys<br />

(requirement: Automation License Manager, V2.x and higher)<br />

Added value<br />

USB FlashDrive<br />

SIMATIC I<strong>PC</strong> BIOS-Manager (DOS and Windows version)<br />

included in scope of supply<br />

Service USB FlashDrive<br />

SIMATIC I<strong>PC</strong> Image & Partition Creator and SIMATIC I<strong>PC</strong><br />

BIOS-Manager V3.1 (Win PE) already preinstalled.<br />

■ Application<br />

The SIMATIC I<strong>PC</strong> USB FlashDrive is a fast and simple method of<br />

saving your data (e. g. recipes, configuration data, etc.) and<br />

transporting it easily from one place to another; it can also be<br />

used as starting medium for SIMATIC I<strong>PC</strong> BIOS-Manager and<br />

SIMATIC I<strong>PC</strong> Image & Partition Creator. In addition, it is ideal as<br />

a storage medium for transportable applications ("portable<br />

apps").<br />

5/258<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Function<br />

Functional highlights/outstanding technical features<br />

Rugged metal enclosure, ultra-compact design<br />

(dimensions: 59.1 x 16.7 x 7 mm) and high electromagnetic<br />

compatibility in accordance with CE Industry make the stick<br />

particularly suitable for industrial use.<br />

High memory capacity of 8 GB<br />

SLC-Flash technology for maximum data security and<br />

performance<br />

High data transmission rate (USB 2.0 interface)<br />

Bootable with operating system (WinPE) and the auxiliary tool<br />

SIMATIC I<strong>PC</strong> BIOS Manager<br />

Perfect as boot medium for SIMATIC I<strong>PC</strong> Image & Partition<br />

The SIMATIC I<strong>PC</strong> USB FlashDrive is the ideal mobile storage<br />

Creator<br />

medium for industrial applications. Thanks to the rugged and<br />

ultra-compact construction in a metal enclosure, fast data<br />

Immediately ready to use – "Plug & Play", no driver necessary<br />

transfer (USB 2.0) and the high memory capacity of 8 GB, the (Windows 2000 or higher)<br />

USB FlashDrive is ideally suited for use in industrial applications. Status LED for indicating the operating state and data<br />

It replaces diskettes, CD and DVD read/write media as data transmission<br />

memory. Thanks to its high access speed, it is also ideal for tools<br />

System-tested with SIMATIC I<strong>PC</strong>/PG<br />

that are not to be installed on the computer ("portable apps"). In<br />

addition, it can be set up ready to boot using SIMATIC <strong>PC</strong> BIOS- For functions of the SIMATIC I<strong>PC</strong> Image & Partition Creator,<br />

Manager. There is an option of expanding the USB FlashDrive see page 5/271<br />

set up in this way into a "tool stick" using SIMATIC I<strong>PC</strong> Image & Recommended operating systems:<br />

Partition Creator.<br />

Windows 2000/XP/Vista/Windows 7/Windows Server 2003/2008<br />

The SIMATIC I<strong>PC</strong> SERVICE USB FlashDrive is the perfect tool for<br />

backup and restoring. With the pre-installed SIMATIC I<strong>PC</strong><br />

Image & Partition Creator V3.1, it is immediately ready to use. ■ Technical specifications<br />

SIMATIC I<strong>PC</strong> USB FlashDrive<br />

SIMATIC I<strong>PC</strong> Service USB FlashDrive<br />

Supported operating systems Windows 2000/XP/Vista/<br />

Windows 7/Windows Server 2003/<br />

2008<br />

Capacity 8GB<br />

Approvals<br />

Temperature<br />

CE Industry<br />

During operation +5 ... +55 °C<br />

Storage -40 ... +70 °C<br />

Device dimensions (L x W x H) in<br />

mm<br />

59.1 x 16.7 x 7<br />

Weight, approx. 12 g<br />

■ Ordering data Order No.<br />

SIMATIC I<strong>PC</strong> USB FlashDrive 6ES7 648-0DC50-0AA0<br />

8 GB (SLC), USB 2.0, metal<br />

enclosure, boot capability, for<br />

SIMATIC I<strong>PC</strong>: Rack <strong>PC</strong>, Box <strong>PC</strong>,<br />

Panel <strong>PC</strong> and for SIMATIC PG<br />

SIMATIC I<strong>PC</strong> Service USB 6AV7 672-8JD01-0AA0<br />

FlashDrive<br />

8 GB (SLC), USB 2.0, metal<br />

enclosure, boot capability,<br />

SIMATIC I<strong>PC</strong> Image & Partition<br />

Creator V3.1 and<br />

SIMATIC I<strong>PC</strong> BIOS-Manager V3.0<br />

(Win PE) already installed,<br />

including CD


■ Overview<br />

The SINUMERIK 3.5" floppy disk drive, USB 1.1 is suitable for<br />

archiving user data and can be installed in front panels. The<br />

connection is made via the USB interface.<br />

■ Function<br />

The SINUMERIK 3.5" floppy disk drive, USB 1.1 is designed for<br />

the transfer of user data. Installation in front panels makes it<br />

possible to transfer data without opening the control cabinet<br />

door. High density (1.2/1.44 MB) 3.5" floppy disks can be used<br />

for storing user data.<br />

■ Integration<br />

The SINUMERIK floppy disk drive, USB 1.1 is suitable for<br />

connecting to:<br />

SINUMERIK <strong>PC</strong>U 50.3<br />

SINUMERIK TCU<br />

SIMATIC Panel <strong>PC</strong> 67x/87x/477/577 with Windows 2000/XP<br />

SIMOTION P350 with Windows XP Professional<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

SINUMERIK 3.5" floppy disk drive, USB 1.1<br />

■ Technical specifications<br />

6FC5235-0AA05-1AA2<br />

SINUMERIK 3.5" floppy disk<br />

drive, USB 1.1<br />

Input voltage 5.25 V DC<br />

Power consumption, max. 2.5 W<br />

Degree of protection according to<br />

EN 60529 (IEC 60529)<br />

Front IP54<br />

Rear IP20<br />

Humidity rating based on<br />

EN 60721-3-3<br />

Class 3K5 condensation and<br />

icing excluded. Low air temperature<br />

0 °C (32 °F).<br />

Relative humidity<br />

Storage 5 ... 90%<br />

Transport 5 ... 90%<br />

Operation<br />

Ambient temperature<br />

20 ... <strong>80</strong>%<br />

Storage -20…+60°C (-4…+140°F)<br />

Transport -20…+60°C (-4…+140°F)<br />

Operation 4…50°C (39.2…122°F)<br />

Distance to <strong>PC</strong>U/TCU<br />

Dimensions<br />

5 m (16.4 ft)<br />

Width 145 mm (5.71 in)<br />

Height 50 mm (1.97 in)<br />

Depth 161 mm (6.34 in)<br />

Weight, approx. 0.32 kg (0.71 lb)<br />

Approvals, according to CE, cULus<br />

■ Ordering data Order No.<br />

SINUMERIK 3.5" floppy disk<br />

drive, USB 1.1<br />

Incl. connecting cable<br />

Length: 1 m (3.28 ft)<br />

A 6FC5 235-0AA05-1AA2<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

■ More information<br />

Note for SIMATIC Panel <strong>PC</strong>s<br />

The USB floppy disk drive is approved for the Windows 2000/XP<br />

operating systems. The appropriate drivers for the floppy disk<br />

drive are supplied with the operating system software.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/259<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

<strong>PC</strong> I/O<br />

■ Overview<br />

The <strong>PC</strong> IO expansion extends the rugged use of the<br />

SIMATIC HMI I<strong>PC</strong>427C at the machine level.<br />

You can find further information under industrial <strong>PC</strong> -><br />

SIMATIC <strong>PC</strong> -> SIMATIC Box <strong>PC</strong>.<br />

The I/O expansion enables and supplements the use of the<br />

SIMATIC HMI I<strong>PC</strong>427C with:<br />

extremely compact dimensions (262 mm wide, 134 mm high,<br />

depth from 47 mm)<br />

high system availability (rugged and maintenance-free, since<br />

without rotating parts, for example)<br />

maximum flexibility.<br />

The <strong>PC</strong> IO expansion comprises:<br />

base module with encoder/counter functionality,<br />

<strong>PC</strong>I104 interface to the HO<strong>ST</strong> system and communication<br />

interfaces to the I/O modules<br />

digital and analog I/O modules that are managed by the basic<br />

module<br />

mechanical installation components.<br />

A selection guide with material list for your requirements can be<br />

found at:<br />

www.siemens.com/simatic-pc/pc-io-selection<br />

Module Description<br />

<strong>PC</strong> IO Base 400 (base module) <strong>PC</strong>I104 interface to host<br />

4 encoder inputs, can also be<br />

used as counters if required<br />

4 digital inputs<br />

Management of encoder inputs<br />

and associated counters and up<br />

to four I/O modules over<br />

separate communication interfaces<br />

Power supply distribution for<br />

4 encoders<br />

<strong>PC</strong> IO MOD Digital 010<br />

(digital I/O module 0)<br />

<strong>PC</strong> IO MOD Analog 020<br />

(analog I/O module 0)<br />

<strong>PC</strong> IO KIT 040<br />

(encoder expansion rack)<br />

<strong>PC</strong> IO KIT 030<br />

(I/O expansion rack)<br />

5/260<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

24 binary 24 V inputs<br />

16 binary 24 V outputs<br />

8 analog inputs, 12 bits, 0 to 5 V,<br />

0 to 10 V ± 5 V, ±10 V<br />

8 analog outputs, 16 bits, ±10 V<br />

4 Pt100 connections, 2-wire<br />

For expanding a SIMATIC<br />

Microbox <strong>PC</strong> 420/427B/I<strong>PC</strong>427C.<br />

Connection unit for:<br />

4 encoder inputs<br />

4 digital inputs<br />

Encoder voltage supply<br />

For expanding a SIMATIC<br />

Microbox <strong>PC</strong> 420/427B/I<strong>PC</strong>427C.<br />

Expansion rack to hold<br />

max. 2 I/O modules in the<br />

Microbox <strong>PC</strong> 42x system<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Reduction in standstill times thanks to high system<br />

availability<br />

Monitoring and diagnostic functions (watchdog, heart beat,<br />

short-circuit monitoring, temperature monitoring, broken<br />

cable)<br />

Maintenance-free operation because a fan is not necessary<br />

Service-friendly hardware configuration (easy expansion,<br />

direct plug-in system for easy installation)<br />

High interference immunity (isolated digital I/Os)<br />

Cost reductions through high investment security<br />

High product continuity through long-term secure functionality<br />

in hardware and software<br />

Modules developed and manufactured by <strong>Siemens</strong><br />

Guaranteed spare-parts availability of the components<br />

(5 years)<br />

Reduced costs through high industrial functionality<br />

High degree of industrial compatibility thanks to rugged<br />

construction (solid metal expansion rack, Base 400<br />

permanently screwed to I/O modules) even under extreme<br />

vibration and shock loading, at high temperatures and with<br />

high electromagnetic interference<br />

High degree of flexibility with selection and expansion of<br />

components (inputs and outputs are scalable in terms of type<br />

and number)<br />

Compact, resource-saving construction (four I/O modules or<br />

up to 160 24 V IOs can be operated on one <strong>PC</strong>I load)<br />

Support is available for different operating systems, such as<br />

RMOS3, Windows XP Professional, Windows XP embedded<br />

High performance for fast signal processing in real-time<br />

applications<br />

Cost minimization through time savings<br />

Delivery of fully assembled, turn-key systems<br />

Program examples for support with creating applications<br />

Quick assembly due to integrated terminals with direct plug-in<br />

connection system


■ Application<br />

The SIMATIC HMI I<strong>PC</strong>427C with central I/O expansion provides<br />

mechanical engineers, plant engineers, and switch cabinet<br />

manufacturers with a high performance, compact <strong>PC</strong> platform<br />

for application at the machine or in the process, and applications<br />

in the industrial environment for:<br />

measuring and controlling of process and machine data<br />

(e. g. automated washing systems, robot controls).<br />

The application spectrum of HMI I<strong>PC</strong>427C with a central<br />

I/O expansion ranges from C/C++-based automation solutions<br />

with the well-proven SICOMP RMOS3 operating system with<br />

real-time and multi-function capability to applications based on<br />

Windows XP.<br />

The <strong>PC</strong> IO central I/O expansion has CE certification for use in<br />

the industrial sector as well as in residential and commercial<br />

areas and small businesses when implemented in the<br />

Microbox <strong>PC</strong> 420/427B/I<strong>PC</strong>427C. In addition to industrial applications,<br />

it can also be used in building services automation or in<br />

facilities open to the public.<br />

■ Technical specifications<br />

Electrical data<br />

Supply voltages and current consumption<br />

Parameters Value<br />

Power supply to base module Via <strong>PC</strong>I-104 interface: 3.3 V DC<br />

and 5 V DC<br />

Encoder supply voltage infeed 24 V DC<br />

Current consumption of encoder 0.3 A per encoder<br />

inputs and counters<br />

Power supply to digital I/O<br />

24 V DC<br />

module 0<br />

Current consumption of digital I/O 4A<br />

module 0, max. approx.<br />

Power supply to analog I/O 5 V DC from Base 400<br />

module 0<br />

Current consumption of analog I/O<br />

module 0, max. approx.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

■ Design<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

<strong>PC</strong> I/O<br />

The Base 400 is directly plugged into the <strong>PC</strong>104 slot of the<br />

HMI I<strong>PC</strong>427C; any required encoders or counters are routed<br />

externally through the Kit 040 (encoder expansion rack).<br />

Up to two I/O modules are screwed into the Kit 030 and both<br />

are attached to the HMI I<strong>PC</strong>427C enclosure; flat ribbon cable<br />

provides the electrical connection to Base 400. The I/O can be<br />

connected through direct connectors.<br />

Flexible central expansion under the following boundary<br />

conditions supports the use of up to 320 24 V digital I/Os in<br />

one HMI I<strong>PC</strong>427C:<br />

- Up to three <strong>PC</strong>I104 modules can be used in the<br />

HMI I<strong>PC</strong>427C<br />

- Expandable with up to four expansion frames<br />

- Up to four I/O modules can be operated on one Base 400<br />

- Up to two <strong>PC</strong> IO Mod Analog 020 can be operated on one<br />

Base 400.<br />

Counters and encoder inputs<br />

Parameters Value<br />

Number of counters or encoder 4<br />

inputs on the base module<br />

Input signal from encoder RS 422<br />

Counting depth 32 bits<br />

Encoder input counting frequency ≤ 2MHz<br />

Sampling time for timer or<br />

1MHz or 4MHz<br />

pulse-width measurement<br />

Gate time for frequency<br />

Adjustable in the following<br />

measurement<br />

stages:<br />

8 µs, 32 µs, 128 µs, 512 µs,<br />

2048 µs, 8192 µs, 16384 µs,<br />

32768 µs, 131072 µs, 262144 µs,<br />

524288 µs, 1048576 µs,<br />

2097152 µs, 4194304 µs,<br />

8388608 µs, 16777216 µs<br />

Isolation No<br />

Protected against polarity reversal No<br />

5/261<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

<strong>PC</strong> I/O<br />

■ Technical specifications (continued)<br />

Digital inputs on base module<br />

Base module: Digital inputs<br />

Parameters Value<br />

Number of digital inputs 4<br />

Cable length (without lightning<br />

protection element)<br />

max. 30 m<br />

Input voltage 24 V DC<br />

Input current Approx. 2 mA<br />

Time constant of input filter 0.01 ms<br />

Isolation No<br />

Digital I/O module 0: Digital inputs<br />

Parameters Value<br />

Number of digital inputs 24<br />

Cable length<br />

max. 30 m<br />

(without lightning protection<br />

element)<br />

Input voltage 24 V DC<br />

Input current Approx. 2 mA<br />

Time constant of input filter<br />

Inputs 0 … 7 0.1 ms<br />

Inputs 8 … 23 1ms<br />

Inputs 8 and 9 also designed as 0.01 ms<br />

high-speed inputs (parallel to 1 ms<br />

path)<br />

Isolation<br />

For communication between the Yes<br />

base module and the inputs of<br />

digital I/O module 0<br />

Isolation test voltage 500 V DC<br />

Between the individual inputs/ No, one electrical circuit<br />

outputs of digital<br />

I/O module 0<br />

5/262<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Digital I/O module 0: Digital outputs<br />

Parameters Value<br />

Number of outputs 16,<br />

Organized in 4 output groups<br />

Cable length (without lightning max. 30 m<br />

protection element)<br />

Output voltage 24 V DC<br />

Output current<br />

Per output group 1A max.<br />

Total per digital I/O module 0 4A max.<br />

Switching rate ≤ 2kHz<br />

Switching type Current sourcing<br />

Output delay<br />

Internal transmission delay 16 µs<br />

Register output to driver output<br />

(load-dependent):<br />

0→ 1 signal max. 30 µs<br />

1→ 0 signal (with a digital input max. 130 µs<br />

connected)<br />

Isolation<br />

For communication between the Yes<br />

base module and the outputs of<br />

digital I/O module 0<br />

Isolation test voltage 500 V DC<br />

Between the individual inputs/ No, one electrical circuit<br />

outputs of digital I/O module 0<br />

Short-circuit protection of the output Threshold on<br />

drivers<br />

Typ. 9 A max. 11 A electronically<br />

pulsing<br />

In order to comply with UL<br />

requirements, the user must limit<br />

the input current to 4 A.<br />

Use NEC Class 2 current source<br />

Excess temperature shutdown Above 150 °C<br />

Overvoltage protection Typ. 47 V<br />

max. 52 V<br />

Status after POWER ON and after High resistance<br />

RESET


■ Technical specifications (continued)<br />

Analog I/O module<br />

Analog I/O module 0: Analog inputs<br />

Parameters Value<br />

Number of analog inputs 8<br />

Shielded cable length max. 30 m<br />

Voltage ranges 0 … 5 V<br />

0 … 10 V<br />

±5 V<br />

±10 V<br />

Permissible input voltage against<br />

analog ground<br />

max. 15 V, continuous<br />

Impedance >10kOhms<br />

Input type Single-ended<br />

Resolution 12 bits (including sign)<br />

Repeatability 10 bits (including sign)<br />

Input filters No<br />

Conversion time max. 200 µs per channel<br />

Configuration cycle time for<br />

analog-to-digital conversion:<br />

Without Pt100 With Pt100<br />

With one analog input 50 ... 100 µs 50 ... 200 µs<br />

With 4 analog inputs 200 ... 400 µs 200 ... 500 µs<br />

With 8 analog inputs 400 ... <strong>80</strong>0 µs 400 ... 1000 µs<br />

Isolation No<br />

Analog I/O module: Pt100 inputs<br />

Parameters Value<br />

Number of external Pt100 inputs 4<br />

Type Two-wire measurement<br />

Dynamic response The mean value is constantly<br />

available and is updated<br />

approximately every 6 ms.<br />

Isolation No<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

Analog I/O module 0: Analog outputs<br />

Parameters Value<br />

Number of analog outputs 8<br />

Type Single-ended<br />

Shielded cable length max. 30 m<br />

Voltage range ±10 V<br />

Load current 2mA max.<br />

Resolution 16 bits (including sign)<br />

Accuracy 0.5%<br />

Conversion time max. 200 µs per channel<br />

Output value after POWER ON and<br />

after RESET<br />

Configuration cycle time for<br />

digital-to-analog conversion<br />

0V<br />

1) :<br />

With one analog input 100 ... 200 µs<br />

With 4 analog inputs 400 ... <strong>80</strong>0 µs<br />

With 8 analog inputs <strong>80</strong>0 ... 1600 µs<br />

Short-circuit protection No<br />

Isolation No<br />

1) The times also depend on the software response time<br />

(interrupt response time or polling times).<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

<strong>PC</strong> I/O<br />

5/263<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

<strong>PC</strong> I/O<br />

■ Technical specifications (continued)<br />

Environmental requirements for installation in Microbox <strong>PC</strong> 42x<br />

Degree of protection to EN 60529<br />

(front/rear)<br />

IP20<br />

Protection class Protection class I acc. to VDE 0106 Part 1 (IEC 536)<br />

Vibration load during operation Devices without hard disk:<br />

Frequency Acceleration Displacement Cycles per axis Octaves/min<br />

10 to 58 Hz - 0.075 mm 10 1<br />

58 to 200 Hz 9.8 m/s2 - 10 1<br />

acc. to IEC 60068-2-6, test Fc<br />

Devices with hard disk: Wall mounting<br />

Frequency Acceleration Displacement Cycles per axis Octaves/min<br />

10 to 58 Hz 0.035 mm 10 1<br />

58 to 200 Hz 4.9 m/s2 10 1<br />

Shock loading during operation<br />

Standard rail: No mechanical excitation permitted<br />

Devices without hard disk:<br />

Acceleration Shock duration<br />

150 m/s2 acc. to IEC 60068-2-27, test Ea<br />

11 ms<br />

3 in both pos. and neg. direction per axis, half-sine<br />

Devices with hard disk: Wall mounting:<br />

Acceleration Shock duration<br />

50 m/s2 30 ms<br />

Standard rail: No mechanical excitation permitted<br />

Electromagnetic compatibility<br />

(EMC)<br />

Emitted interference EN 55022 Class B<br />

In order to comply with Class B, a 230 V AC power supply unit must be used which meets the requirements<br />

of EN 55022 Class B (e. g. "SITOP modular 5 A", type No.: 6EP1333-3BA00).<br />

Immunity to conducted<br />

±2 kV (IEC 61000-4-4, Burst)<br />

interference on the supply lines ±1 kV (IEC 61000-4-5, symm. surge, length > 30 m)<br />

with lightning protection element (e. g. from Dehn, type "Blitzductor BVT AD24", type No.: 918402)<br />

±2 kV (IEC 61000-4-5, unsymm. surge, length > 30 m)<br />

with lightning protection element (e. g. from Dehn, type "Blitzductor BVT AD24", type No.: 918402)<br />

Immunity to conducted inter- ±2 kV (IEC 61000-4-4, burst)<br />

ference on the unshielded supply ±1 kV (IEC 61000-4-5, symm. surge, length > 30 m)<br />

lines<br />

with lightning protection element (e. g. from Dehn, type "Blitzductor BVT AD24", type No.: 918402)<br />

±2 kV (IEC 61000-4-5, unsymm. surge) Length > 30 m)<br />

with lightning protection element (e. g. from Dehn, type "Blitzductor BVT AD24", type No.: 918402)<br />

Immunity to conducted inter- ±2 kV (IEC 61000-4-4, burst)<br />

ference on the shielded supply ±1 kV (IEC 61000-4-5, surge symm., length > 30 m)<br />

lines<br />

±2 kV (IEC 61000-4-5, surge unsymm., length > 30 m)<br />

Immunity to static discharge ±6 kV, contact discharge (IEC 61000-4-2)<br />

±8 kV, air discharge (IEC 61000-4-2)<br />

Immunity to radio frequency 10 V/m <strong>80</strong>% AM; <strong>80</strong> MHz to 1 GHz (IEC 61000-4-3);<br />

interference<br />

10 V/m <strong>80</strong>% AM; 1.4 GHz to 2 GHz (IEC 61000-4-3)<br />

Immunity to high-frequency<br />

current feed<br />

10 V <strong>80</strong>% AM, 9 kHz to <strong>80</strong> MHz (IEC 61000-4-6)<br />

Ambient temperature during<br />

0 to 50 ºC with Flash drive (horizontal; preferred mounting position)<br />

operation<br />

0 to 45 ºC with Flash drive (vertical)<br />

5 to 40 ºC with hard disk (horizontal and vertical)<br />

Ambient temperature during<br />

storage and transport<br />

-20°C … +60°C<br />

Moist heat 30 °C/85% (IEC 60068-2-78, Test Cab)<br />

5/264<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Technical specifications (continued)<br />

Environmental requirements for installation in Microbox <strong>PC</strong> 42x<br />

Approvals<br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

Safety regulations IEC/EN 60950-1<br />

CE marking EC Directive 89/336/EEC (EMC Directive)<br />

Use in industry:<br />

Applications in residential areas, business and trade environments as well as in workshops:<br />

- Emitted interference: EN 61000-6-4<br />

- Noise immunity: EN 61000-6-2<br />

Applications in residential areas, business and trade environments as well as in workshops:<br />

- Emitted interference: EN 61000-6-3<br />

- Noise immunity: EN 61000-6-1<br />

Dimensions and weights<br />

Equipment dimensions (in mm) Width x height: 262 x 134<br />

Depth of basic unit: 47<br />

Depth of basic unit above rail: 52<br />

Additional depth per encoder expansion rack (Kit 040): 17<br />

Additional depth per I/O expansion rack (Kit 030): 22<br />

■ Ordering data Order No. Order No.<br />

<strong>PC</strong> IO Base 400 A 6ES7 648-2CE20-0AA0<br />

<strong>PC</strong> IO KIT 030 6ES7 648-1AA20-0XF0<br />

<strong>PC</strong>I104 module for connecting up<br />

I/O module expansion rack for<br />

to 4 <strong>PC</strong> IO MOD xxx 010/020, with<br />

Microbox <strong>PC</strong> 420/427B/I<strong>PC</strong>427C<br />

4 encoder interfaces and<br />

for installing up to 2 I/O modules,<br />

4 DI incl. fixing accessories (base<br />

including fixing accessories and<br />

module with fixing accessories)<br />

a cover plate<br />

<strong>PC</strong> IO MOD Digital 010 A 6ES7 648-2CE40-0BA0<br />

<strong>PC</strong> IO KIT 040 6ES7 648-1AA20-0XE0<br />

Digital I/O module with 24 DI and<br />

Encoder expansion rack for<br />

16 DO, incl. connecting cable to<br />

Microbox <strong>PC</strong> 420/427B/I<strong>PC</strong>427C<br />

<strong>PC</strong> IO Base 400 and mating<br />

for contacting the encoder inter-<br />

connector<br />

faces and DIs of the <strong>PC</strong> IO<br />

<strong>PC</strong> IO MOD Analog 020<br />

Analog I/O module with 8AI,<br />

8 AO and 4 PT100, incl.<br />

connecting cable to<br />

<strong>PC</strong> IO Base 400, mating<br />

connector and shield clamp<br />

A 6ES7 648-2CE40-0CA0<br />

Base 400, including fixing accessories<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

<strong>PC</strong> I/O<br />

5/265<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

Industrial USB Hub 4<br />

■ Overview<br />

Industrial USB Hub 4, open<br />

The Industrial USB Hub 4 is used as a USB hub for the<br />

connection of I/O devices to Multi Panels, Panel <strong>PC</strong>s and<br />

standard <strong>PC</strong>s.<br />

The industrial USB Hub 4 with IP65 degree of protection on the<br />

front (Service Kit required) can be mounted in a control<br />

cabinet. This simplifies the use of USB I/O in harsh industrial<br />

environments.<br />

USB I/O can be connected to the panel and operated via the<br />

Industrial USB Hub 4 without opening the cabinet door. The<br />

interfaces are also accessible from the rear even in the control<br />

cabinet.<br />

5/266<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Design<br />

Use of the Industrial USB Hub 4<br />

permits the simultaneous connection of as many as four<br />

I/O devices such as USB stick, mouse, keyboard, printer or<br />

barcode reader to the panel.<br />

increases the availability of the system to be operated. The<br />

cabinet door no longer has to be opened in order to connect<br />

to the I/O. The unit can be operated from the Panel <strong>PC</strong> and the<br />

Multi Panel without interruption.<br />

In addition, the Industrial USB Hub4 has the following features:<br />

Inspection window for each interface<br />

Vibration-proof restraint of connected USB cables and<br />

USB sticks<br />

One LED per interface for checking the data traffic<br />

Sufficient interior space for easy insertion and removal of<br />

connections<br />

Facility for attachment to a DIN rail<br />

Voltage connection for 24 V DC<br />

■ Integration<br />

The Industrial USB Hub 4 is suitable for connection to:<br />

Multi Panels<br />

SIMATIC I<strong>PC</strong><br />

Standard <strong>PC</strong><br />

Recommended operating systems:<br />

Windows CE/2000/XP/XP embedded


© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

Industrial USB Hub 4<br />

■ Technical specifications ■ Ordering data Order No.<br />

6AV6 671-3AH00-0AX0<br />

Industrial USB Hub 4 A 6AV6 671-3AH00-0AX0<br />

Product type designation Industrial USB Hub 4<br />

4 x USB 2.0, IP65, for control<br />

Supply voltage<br />

Supply voltage 24 V DC<br />

cabinet door or standard rail,<br />

usable with MP 177/MP 277/<br />

MP 377, Panel <strong>PC</strong>s, HMI I<strong>PC</strong>s<br />

permissible range +20.4 V to +28.8 V DC<br />

and standard <strong>PC</strong>s<br />

Ambient conditions<br />

max. relative humidity 90%<br />

Service pack for Industrial USB<br />

Hub 4<br />

see HMI accessories service<br />

packets (incl. IP65 expansion)<br />

Temperature<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

Operation (vertical installation) 0 °C to +50 °C<br />

Transport, storage<br />

Degree of protection<br />

-20 °C to +60 °C<br />

■ More information<br />

IP65 at front Yes<br />

Note for SIMATIC Panel <strong>PC</strong>s<br />

IP20 rear Yes<br />

The Industrial USB Hub 4 is approved for the Windows<br />

Certifications & standards<br />

Certifications<br />

Interfaces<br />

CE<br />

CE/2000/XP operating systems. The appropriate drivers are<br />

supplied with the operating system software.<br />

Number of USB interfaces<br />

General information<br />

4; 500 mA each, e. g. mouse,<br />

keyboard, printer, USB stick<br />

belongs to product/product range<br />

Dimensions<br />

MP 277, Panel <strong>PC</strong><br />

External dimensions (W x H x D)<br />

in mm<br />

Dimensions and weight<br />

Weight<br />

212 x 156 x 50<br />

Weight 0.5 kg<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/267<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

SIMATIC Panel <strong>PC</strong> Remote Kit<br />

■ Overview<br />

The Remote Kit makes it possible to separate the Panel <strong>PC</strong> 677B<br />

operator control unit from the computer unit and install them up<br />

to 30 m apart.<br />

5/268<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Maintaining the Panel <strong>PC</strong> front functionality<br />

- Status LEDs (temperature/power)<br />

- LEDs on the keys, Piezo mouse<br />

- USB 2.0 on front (up to 5 m), USB 1.1 (up to 30 m)<br />

- Dimmable backlit display<br />

- Programmable keyboard controller<br />

- Direct control key module option available and mountable<br />

Makes an ultra-compact operator control unit possible<br />

Suitable for subsequent modification/upgrade by the<br />

customer<br />

Can be used for all SIMATIC Panel <strong>PC</strong>s 677B<br />

Pure hardware solution and, therefore, independent of the<br />

operating system<br />

Remote front with the option of AC or DC power supply<br />

Operator control unit can be located up to 30 m away from the<br />

computer unit<br />

Two additional USB ports on rear, USB 2.0: up to 5 m highspeed,<br />

up to 30 m full-speed<br />

■ Application<br />

The Panel <strong>PC</strong> Remote Kit is designed for use exclusively with a<br />

Panel <strong>PC</strong> 677B. The Remote Kit can only be operated using the<br />

cables included in the scope of delivery.<br />

■ Design<br />

The Remote Kit consists of the following components:<br />

Remote module (mounted on the rear of the operator control<br />

unit)<br />

Video connecting cable (industrial grade DVI-D cable)<br />

USB connecting cable (up to 5 m with a standard USB cable;<br />

at 5 m and longer, the USB signal is transmitted via a<br />

CAT6 cable with external amplification)<br />

Mechanical components (for mounting the computer unit<br />

inside a control cabinet, console or machine)


© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

SIMATIC Panel <strong>PC</strong> Remote Kit<br />

■ Technical specifications ■ Ordering data Order No.<br />

SIMATIC Panel <strong>PC</strong> Remote Kit<br />

SIMATIC Panel <strong>PC</strong> Remote Kit<br />

Design Subsequent installation on the 24 V DC, 5 m A 6AV7 671-1EA00-5AA1<br />

Panel <strong>PC</strong> 677B operator control<br />

unit<br />

24 V DC, 10 m A 6AV7 671-1EA01-0AA1<br />

Supported operator control units All Panel <strong>PC</strong> 677B operator<br />

24 V DC, 15 m A 6AV7 671-1EA01-5AA1<br />

control units:<br />

12" Touch/Key<br />

15" Touch/Key<br />

24 V DC, 20 m<br />

24 V DC, 30 m<br />

A<br />

A<br />

6AV7 671-1EA02-0AA1<br />

6AV7 671-1EA03-0AA1<br />

Cable sets<br />

17" Touch<br />

19" Touch<br />

5 m<br />

10 m<br />

100/240 V AC, 5 m<br />

100/240 V AC, 10 m<br />

100/240 V AC, 15 m<br />

A<br />

A<br />

A<br />

6AV7 671-1EA10-5AA1<br />

6AV7 671-1EA11-0AA1<br />

6AV7 671-1EA11-5AA1<br />

15 m<br />

20 m<br />

100/240 V AC, 20 m A 6AV7 671-1EA12-0AA1<br />

30 m<br />

100/240 V AC, 30 m A 6AV7 671-1EA13-0AA1<br />

Front panel functionality As centralized installation with the<br />

following constraint in respect of<br />

USB functionality:<br />

Accessories<br />

Power supply cable<br />

Distance 5 m: USB 2.0, and only<br />

one external 2.0 Hub<br />

Distance > 5 m: USB 1.1, and<br />

only one external 1.1 Hub<br />

Europe: GER/FR/NL/ENG/B/A/SP/<br />

FIN<br />

External ports 2 additional USB ports on the<br />

remote module (on the rear of the<br />

remote operator control unit)<br />

Power supply 24 V DC; 20.4 ... 28.8 V DC or<br />

110 ... 240 V AC; 50/60 Hz<br />

Approvals CE, cULus (UL 508)<br />

Scope of supply Remote module<br />

Cable set<br />

Mounting accessories for the<br />

<strong>PC</strong> 677B computer unit<br />

European power supply cable<br />

(with the AC option)<br />

1)<br />

United Kingdom<br />

6ES7 900-1AA00-0XA0<br />

6ES7 900-1BA00-0XA0<br />

Switzerland 6ES7 900-1CA00-0XA0<br />

USA 6ES7 900-1DA00-0XA0<br />

Italy 6ES7 900-1EA00-0XA0<br />

China 6ES7 900-1FA00-0XA0<br />

Sub-components of the<br />

Remote Kit<br />

(only available individually as<br />

spare parts)<br />

24 V DC remote module with<br />

fixing accessories<br />

A 6AV7 671-1EX01-0AD0<br />

110/240 V AC remote module with A<br />

fixing accessories<br />

6AV7 671-1EX01-0BD0<br />

USB amplifier/CAT6 converter 6AV7 671-1EX02-0AB0<br />

5 m cable set (DVI, USB standard<br />

cable)<br />

6AV7 671-1EX10-5AA0<br />

10 m cable set (DVI, Cat 6 cable) 6AV7 671-1EX11-0AA0<br />

15 m cable set (DVI, Cat 6 cable) A 6AV7 671-1EX11-5AA0<br />

20 m cable set (DVI, Cat 6 cable) 6AV7 671-1EX12-0AA0<br />

30 m cable set (DVI, Cat 6 cable) 6AV7 671-1EX13-0AA0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

1) A European power supply cable is included in the scope of delivery of<br />

the AC (100-240 V) version of the Remote Kit.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/269<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

SIMATIC Panel <strong>PC</strong> Remote Kit<br />

■ Dimensional drawings<br />

All specifications in mm. Panel cutout see technical specifications.<br />

SIMATIC Panel <strong>PC</strong> Remote Kit<br />

5/270<br />

W<br />

W+1 (cutout)<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

H+1 (cutout)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

H<br />

D<br />

10,5<br />

Front dimensions W H<br />

Touch panels<br />

12"<br />

15"<br />

19"<br />

Key Panels<br />

12"<br />

15"<br />

Installation cutout<br />

Touch panels<br />

12"<br />

15"<br />

19"<br />

Key Panels<br />

12"<br />

15"<br />

368<br />

450<br />

450<br />

400<br />

483<br />

483<br />

483<br />

483<br />

290<br />

290<br />

3<strong>80</strong><br />

310<br />

310<br />

400<br />

310<br />

355<br />

W+1 H+1 D<br />

95<br />

93<br />

102<br />

450 290 77<br />

450 321*<br />

96<br />

* In addition: two recesses 25 x 5 mm on the top side<br />

for keyboard slide-in label channels G_<strong>ST</strong><strong>80</strong>_XX_00267


■ Overview<br />

SIMATIC I<strong>PC</strong> Image & Partition Creator V3.1 is the software tool<br />

for easy, preventive back-up and restoring of hard disk contents<br />

(images of individual partitions or complete hard disks). This<br />

software can be ordered through the Configurator for the<br />

SIMATIC I<strong>PC</strong>s, or separately with a single license.<br />

Can run on all SIMATIC I<strong>PC</strong>s, regardless of the computer<br />

configuration<br />

Direct starting from the CD possible (no installation required in<br />

that case)<br />

Complete backup by means of a mouse double-click with<br />

"1ClickImage" (must be installed in this case)<br />

Menu-driven creation of a bootable USB flash drive as an<br />

alternative start medium from which Image & Partition Creator<br />

can then be started.<br />

Independent of the operating system thanks to ability to start<br />

from the bootable Image & Partition Creator CD or bootable<br />

USB flash drive with Image & Partition Creator<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

■ Benefits<br />

SIMATIC I<strong>PC</strong> Image & Partition Creator<br />

Data security and hard disk management with very little<br />

overhead<br />

Hard disk partitions can be modified without loss of data and<br />

without the need for reinstallation<br />

Hard disk contents can be saved quickly, accurate to a bit,<br />

and securely<br />

No changes to the target system to be processed (when<br />

starting directly from the CD or USB FlashDrive with<br />

Image & Partition Creator)<br />

Reliable deletion of confidential data<br />

Can be used with any SIMATIC I<strong>PC</strong> hardware, independent of<br />

the respective I<strong>PC</strong> configuration (even devices with<br />

CompactFlash cards and solid-state drive)<br />

Cost reduction due to considerably reduced downtimes in<br />

the event of an error<br />

Following replacement of a hard disk, SIMATIC I<strong>PC</strong>s are ready<br />

for operation again in just a few minutes<br />

Software failures due to application errors, operator errors or<br />

computer viruses can be rectified in a matter of minutes<br />

■ Application<br />

SIMATIC I<strong>PC</strong> Image & Partition Creator should be used on all<br />

SIMATIC I<strong>PC</strong>s/HMI I<strong>PC</strong>s for subsequent adjustment of existing<br />

hard disk partitioning and for all data backups if there is no<br />

central backup solution via LAN.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/271<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

SIMATIC I<strong>PC</strong> Image & Partition Creator<br />

■ Function<br />

SIMATIC I<strong>PC</strong> Image & Partition Creator V3.1 continues to<br />

offer the functionality its users valued in the past:<br />

High-speed and accurate backup and restoring of hard disk<br />

contents. This restoration requires considerably less time<br />

compared to a reinstallation.<br />

Simple duplication of existing software installations to other<br />

devices with the same equipment and same use (cloning).<br />

This enables a quick complete replacement of equipment in<br />

the event of servicing<br />

Automatic driver support for the latest SIMATIC I<strong>PC</strong>s<br />

Complete backup by means of a mouse double-click with<br />

"1ClickImage" after one-time configuration of backup path<br />

Menu-driven creation of a bootable USB flash drive with<br />

Image & Partition Creator as an alternative start medium<br />

(instead of CD)<br />

Menu-driven creation of an entry for the USB flash drive in the<br />

Windows boot menu for easy booting from the USB flash drive<br />

Time-controlled backup: The start of a previously configured<br />

complete backup via the imaging software or Windows Task<br />

Planner enables regular, unsupervised backups at any time.<br />

Functions for changing hard disk partitions:<br />

Enlarge and reduce existing system and data partitions<br />

without any loss of data<br />

Create new partitions or delete existing ones<br />

Convert the file system (e.g. FAT32 to NTFS)<br />

Simple setup of multiple-boot systems. Installation of a boot<br />

manager<br />

SIMATIC I<strong>PC</strong> Image & Partition Creator V3.1 offers the<br />

following new functions:<br />

Direct start (without installation) from the Windows autostart<br />

menu<br />

System backups even during operation<br />

Backup of files and folders<br />

Menu-driven creation of a protected "backup container"<br />

Irrevocable deletion of data<br />

Support of virtual drives<br />

With the above-named functions, the existing installation should<br />

continue to function without restrictions (except in the case of<br />

deletions).<br />

5/272<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

System requirements:<br />

Hardware:<br />

SIMATIC <strong>PC</strong>s of the B generation<br />

SIMATIC I<strong>PC</strong>s of the C generation<br />

SIMATIC Field PG M2 / M3<br />

SINUMERIK <strong>PC</strong>U50.3<br />

SIMOTION P350-3 / 350-5<br />

Software:<br />

Operating system for installation: Windows XP, Windows Vista,<br />

Windows 2003/ 2008 Server, Windows 7<br />

Compatibility:<br />

SIMATIC I<strong>PC</strong> Image & Partition Creator V3.x is not imagecompatible<br />

with previous versions.<br />

■ Ordering data Order No.<br />

SIMATIC I<strong>PC</strong> Image & Partition<br />

CreatorV3.1<br />

SIMATIC I<strong>PC</strong> Image & Partition<br />

Creator V3.1<br />

Software tool for very easy<br />

preventive data backup and<br />

efficient partition management on<br />

SIMATIC I<strong>PC</strong>s<br />

Can be ordered using the<br />

SIMATIC I<strong>PC</strong> Configurator<br />

D 6ES7 648-6AA03-1YA0<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

Note:<br />

SIMATIC Image & Partition Creator is also available together with<br />

the SIMATIC I<strong>PC</strong> BIOS Manager preinstalled with the<br />

SIMATIC I<strong>PC</strong> Service USB FlashDrive.


■ Overview<br />

SIMATIC I<strong>PC</strong> DiagMonitor: Intelligent and comprehensive<br />

diagnostics for the SIMATIC I<strong>PC</strong> – local and remote.<br />

The SIMATIC I<strong>PC</strong> DiagMonitor software for monitoring and<br />

remote signaling detects possible hardware and software faults<br />

at an early stage. It monitors, signals and visualizes the<br />

operating statuses of the SIMATIC I<strong>PC</strong> both locally and remotely.<br />

DiagMonitor V4.2 can run on the following SIMATIC I<strong>PC</strong>s:<br />

Microbox <strong>PC</strong> 427B<br />

Box <strong>PC</strong> 627B/827B<br />

Rack <strong>PC</strong> IL 43 / 547B / 647B / 847B<br />

Panel <strong>PC</strong> 477B/577B/677B<br />

I<strong>PC</strong>427C / I<strong>PC</strong>627C<br />

I<strong>PC</strong>547C / I<strong>PC</strong>647C / I<strong>PC</strong>847C<br />

HMI I<strong>PC</strong>477C / HMI I<strong>PC</strong>477C PRO / HMI I<strong>PC</strong>577C /<br />

HMI I<strong>PC</strong>677C<br />

The software can be ordered as:<br />

Individual product from stock (e. g. for server applications on<br />

third-party <strong>PC</strong>s or immediate integration in new systems) or<br />

Option ordered according to the SIMATIC I<strong>PC</strong> configurator<br />

(Internet, Mall).<br />

(DiagMonitor V3.1 is used with SIMATIC Microbox <strong>PC</strong> 420/427B,<br />

Box <strong>PC</strong> 627/627B, Rack <strong>PC</strong> IL 43/840/847B, Panel <strong>PC</strong> 477/477B/<br />

677/677B/877 and can be ordered directly via the <strong>PC</strong> configurator<br />

or as an individual product.)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

■ Benefits<br />

SIMATIC I<strong>PC</strong> DiagMonitor<br />

Investment security thanks to increased system availability<br />

Diagnostics and signaling functions for <strong>PC</strong> temperature, fan,<br />

hard disks (RAID, SMART, CompactFlash Card, SSD),<br />

operating system status (watchdog)<br />

Runtime meter for preventive maintenance<br />

Integrated log function, comprehensive text messages, online<br />

help English/German<br />

Worldwide diagnostics via Internet thanks to integrated web<br />

server function<br />

Reduced costs thanks to minimization of downtimes<br />

Fast fault signaling thanks to communication by means<br />

of e-mails and text messages<br />

Fast response thanks to communication in the application<br />

through O<strong>PC</strong> (client) and SNMP<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/273<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

SIMATIC I<strong>PC</strong> DiagMonitor<br />

■ Function<br />

SIMATIC I<strong>PC</strong> DiagMonitor monitors, signals, and communicates<br />

with a central server, acts in the event of an alarm, and logs the<br />

system states of the SIMATIC I<strong>PC</strong>s.<br />

It monitors<br />

processor and internal device temperatures<br />

fans<br />

operating system status by means of "watchdog"<br />

function of the hard drive or RAID system using the S.M.A.R.T.<br />

diagnostic bytes<br />

new generation of the SIMATIC I<strong>PC</strong> CompactFlash Card with<br />

diagnostic capability<br />

It signals<br />

accumulated operating hours for controlling service intervals<br />

each alarm and logs it<br />

overshoot/undershoot of permissible operating temperature<br />

program interruption following a watchdog timeout<br />

hard drive problems<br />

It communicates<br />

locally with an O<strong>PC</strong> client<br />

locally via DLL or SNMP with a central server<br />

remotely over LAN, e-mail, text messages<br />

via diagnostic LEDs and 7-segment displays on the device<br />

worldwide over the Internet through a web server<br />

It acts in the event of an alarm<br />

by starting customer applications<br />

through predefined applications (e. g. restart)<br />

It logs<br />

all alarms and operations automatically in a log file<br />

measured data (temperature, fan) over the operating period<br />

It visualizes<br />

recorded measuring data (with trend analysis)<br />

It synchronizes<br />

system time over LAN (e. g. maintenance-free operation<br />

without CMOS battery)<br />

Furthermore, customers have the option of creating their own<br />

applications via a programming interface.<br />

As a useful enhancement when purchasing SIMATIC I<strong>PC</strong><br />

DiagMonitor, the user also receives the SIMATIC <strong>PC</strong> web<br />

business card for free. The web business card is a component<br />

of the diagnostic software and provides information about the<br />

SIMATIC I<strong>PC</strong> via the web server. The following is displayed:<br />

Device data, e. g. product designation, BIOS version,<br />

mainboard number<br />

System status<br />

5/274<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

System requirements:<br />

Executable with:<br />

Microsoft Windows 2000 Professional<br />

Microsoft Windows XP Professional<br />

Microsoft Windows XP Embedded (SIMATIC <strong>PC</strong> configuration)<br />

Microsoft Windows Vista Ultimate (32 bit)<br />

Microsoft Windows 2003 Server Edition (32 bit)<br />

Microsoft Windows 2008 Server Edition (32 bit)<br />

Microsoft Windows Embedded Standard 2009<br />

(SIMATIC I<strong>PC</strong> configuration)<br />

Microsoft Windows 7 Ultimate (32 bit)<br />

■ Ordering data Order No.<br />

SIMATIC I<strong>PC</strong> DiagMonitor V4.2 Can be ordered using the<br />

SIMATIC I<strong>PC</strong> Configurator<br />

SIMATIC I<strong>PC</strong> DiagMonitor V4.2 6ES7 648-6CA04-2YX0<br />

Software tool for monitoring the<br />

SIMATIC I<strong>PC</strong>, incl. manual on<br />

CD-ROM (English, German),<br />

single license


■ Overview<br />

SIMATIC I<strong>PC</strong> Remote Manager<br />

Efficient remote maintenance and management of<br />

SIMATIC I<strong>PC</strong>s.<br />

With the SIMATIC I<strong>PC</strong> Remote Manager you can use functions of<br />

the Intel active management technology (Intel AMT) for<br />

SIMATIC I<strong>PC</strong>s. Intel AMT is used for remote management of <strong>PC</strong>s.<br />

■ Benefits<br />

Remote diagnostics and access without on-site support<br />

• Fault correction<br />

• BIOS and program updates<br />

Central service<br />

Admin<br />

• Easy access on SIMATIC I<strong>PC</strong><br />

• Without additional hardware<br />

• Over secure connections<br />

AMT clients<br />

Central service<br />

Simple remote access to AMT clients<br />

Without additional hardware<br />

Via secure connections<br />

Remote diagnostics and access without on-site presence<br />

Troubleshooting<br />

BIOS and program updates<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Control, admin<br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

Resource management<br />

SIMATIC I<strong>PC</strong> Remote Manager<br />

Production<br />

• Saves electricity cost<br />

• Efficient use of production time<br />

Intel AMT offers a range of functions, such as:<br />

Remote reboot<br />

IDE redirection<br />

Keyboard video mouse redirection<br />

Power on / off / reset, and<br />

an integrated Web server.<br />

Resource management<br />

Saving of electricity costs<br />

Efficient use of production time<br />

Without AMT<br />

With AMT<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

G_<strong>ST</strong><strong>80</strong>_XX_00443<br />

5/275<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

SIMATIC I<strong>PC</strong> Remote Manager<br />

■ Function<br />

Operating instructions / restrictions:<br />

SIMATIC I<strong>PC</strong> Remote Management<br />

SIMATIC Device AMT client Admin<br />

computer<br />

Keyboard Video Mouse Redirection (KVM)<br />

This can be used to divert the keyboard video mouse signal of a<br />

Rack <strong>PC</strong> I<strong>PC</strong>647C<br />

I<strong>PC</strong>847C<br />

Processors:<br />

Intel Core i5 or<br />

Core i7BIOS<br />

With any<br />

operating<br />

system and<br />

remote computer to or from an IT computer via a remote<br />

version:<br />

Web browser<br />

connection so that an administrator can access and operate the<br />

computer without additional hardware.<br />

V15.01.05 and<br />

later<br />

With Windows<br />

operating<br />

Remote Power Control<br />

This allows SIMATIC I<strong>PC</strong>s with Intel AMT functions to be<br />

switched off and on via remote access, for maintenance<br />

purposes, for example. If the operating system of the<br />

AMT computer is no longer operable, you can thus still perform<br />

Box <strong>PC</strong><br />

I<strong>PC</strong>547C<br />

I<strong>PC</strong>627C<br />

I<strong>PC</strong>827C<br />

No<br />

Processors:<br />

Core i7BIOS<br />

version:<br />

V15.02.05 and<br />

later<br />

systems and<br />

SIMATIC I<strong>PC</strong><br />

Remote<br />

Manager<br />

a reset or restart. With this function, even the electricity costs of<br />

a company can be reduced e. g. by specifically shutting down<br />

computers left running by employees at night or at the weekend.<br />

Panel <strong>PC</strong> HMI I<strong>PC</strong>677C Processors:<br />

Core i7BIOS<br />

version:<br />

Disk Redirection (IDE-R)<br />

V15.02.05 and<br />

later<br />

The AMT client can read data from an ISO image existing on the<br />

admin computer and start programs, e. g. to carry out BIOS and<br />

software updates.<br />

HMI I<strong>PC</strong>577C<br />

HMI I<strong>PC</strong>477C<br />

No<br />

No<br />

Remote reboot<br />

Microbox <strong>PC</strong> I<strong>PC</strong>427C No<br />

This can be used to reboot the <strong>PC</strong> by remote access from the<br />

hard disk, CD or a network drive, e. g. following a program<br />

update.<br />

Web server<br />

In addition, the Web server integrated in the AMT computer can<br />

be accessed using a Web browser (e. g. Internet Explorer).<br />

Here, you can scan hardware and system information, and<br />

actions such as power on / off / reset can be performed.<br />

Field PG Field PG M2/ No<br />

M3<br />

The SIMATIC I<strong>PC</strong> Remote Manager is offered exclusively with<br />

English menus.<br />

AMT functions are only integrated in the Intel Core i5 and<br />

Core i7 processors of the SIMATIC I<strong>PC</strong>847C, I<strong>PC</strong>627C,<br />

I<strong>PC</strong>647C, I<strong>PC</strong>827C and HMI I<strong>PC</strong>677C devices. With a<br />

Core i3 CPU, iAMT is not possible. A Field PG does not have<br />

integrated AMT functionality either.<br />

System requirements<br />

Hardware requirements for SIMATIC I<strong>PC</strong> Remote Manager:<br />

■ Ordering data Order No.<br />

All SIMATIC <strong>PC</strong>s of the "B" generation<br />

All SIMATIC I<strong>PC</strong>s of the "C" generation<br />

SIMATIC Field PG M2 / M3<br />

SIMATIC I<strong>PC</strong> Remote Manager<br />

V1.0<br />

Software tool for remote maintenance<br />

and management of<br />

6ES7 648-6EA01-0YA0<br />

Operating system requirements for SIMATIC I<strong>PC</strong> Remote<br />

Manager:<br />

Microsoft Windows XP Professional SP3<br />

Microsoft Windows Vista Ultimate SP2<br />

Microsoft Windows Embedded Standard 2009<br />

Microsoft Windows Embedded Standard 2007<br />

Microsoft Windows 7 Ultimate<br />

Microsoft Windows 2003 R2 Server Edition<br />

Microsoft Windows 2008 Server Edition<br />

SIMATIC I<strong>PC</strong>, incl. manual on<br />

CD-ROM (English, German),<br />

single license<br />

5/276<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Overview<br />

The SIMATIC I<strong>PC</strong> BIOS Manager V3.1 (WinPE) is a software tool<br />

for the management and processing of SIMATIC I<strong>PC</strong> BIOS data.<br />

The tool is obtained by downloading it from the Service &<br />

Support web pages of Industry Automation & Drive Technologies<br />

using the Automation Value Card.<br />

http://support.automation.siemens.com/WW/view/en/44443161<br />

■ Benefits<br />

Productivity increase due to efficient and user-friendly BIOS<br />

data management<br />

CMOS data duplicated by means of reading out, saving in a<br />

file, writing to the CMOS<br />

CMOS data saved for documentation and restore purposes<br />

Reading out and saving an inventory number in the SMBIOS<br />

Saving the BIOS image and installing on <strong>PC</strong>s that are identical<br />

in construction<br />

Execution of a BIOS update<br />

■ Application<br />

Wherever SIMATIC I<strong>PC</strong>s are used in industry, they are extended<br />

with modules and software and the BIOS settings (CMOS data)<br />

are correspondingly modified. In this environment, the<br />

SIMATIC I<strong>PC</strong> BIOS Manager can be used as:<br />

Production tool<br />

For the fast configuration of identical CMOS data<br />

Reading of CMOS data from the BIOS<br />

Saving the CMOS data to a file with the addition of userspecific<br />

text<br />

Writing the saved CMOS data to the BIOS<br />

Service/quality tool<br />

Fast, easy storage of <strong>PC</strong> system data for QM requirements<br />

Forwarding the CMOS data to an end user<br />

Uncomplicated on-site restoration of CMOS<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

■ Function<br />

SIMATIC I<strong>PC</strong> BIOS Manager<br />

The SIMATIC I<strong>PC</strong> BIOS Manager V3.1 offers the following<br />

functions:<br />

Management of the BIOS settings (CMOS data) of<br />

SIMATIC I<strong>PC</strong>s:<br />

- Read-out from the BIOS<br />

- Save in a file<br />

- Import from a file<br />

- Save in the BIOS<br />

Display the SMBIOS data of SIMATIC I<strong>PC</strong>s<br />

Execute BIOS update and backup of BIOS image<br />

System requirements:<br />

The requirements for the use of the SIMATIC I<strong>PC</strong> BIOS<br />

Manager V3.1 are:<br />

SIMATIC I<strong>PC</strong>/PG as hardware platform<br />

Windows PE boot medium, e. g. restore or recovery CD/DVD<br />

("C" device generation or higher)<br />

Alternative: SIMATIC I<strong>PC</strong> Image & Partition Creator V3.0 (start<br />

from CD) or USB FlashDrive created by it with Image &<br />

Partition Creator (boot from USB FlashDrive)<br />

■ Ordering data Order No.<br />

SIMATIC I<strong>PC</strong> BIOS Manager<br />

Software tool for the management<br />

and processing of SIMATIC I<strong>PC</strong><br />

BIOS data<br />

as download via<br />

customer support<br />

http://<br />

support.automation.<br />

siemens.com/WW/<br />

view/en/44443161<br />

Note:<br />

SIMATIC I<strong>PC</strong> BIOS Manager is also available together with the<br />

SIMATIC I<strong>PC</strong> USB FlashDrive and I<strong>PC</strong> Service USB FlashDrive.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/277<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

ADDM - Data Management<br />

■ Overview<br />

With ADDM, you are completely in control of the SIMATIC and<br />

SINUMERIK controls – around the clock and with any program<br />

version. This tool is indispensable in a modern production area<br />

and ensures user-friendly backup, comparison and<br />

management of control data.<br />

■ Benefits<br />

Absolute clarity in data management<br />

With ADDM, everything executes on a uniform user interface -<br />

all types and formats of CNC, PLC and configuration data right<br />

through to CNC software. The tool offers unambiguous access<br />

authorizations and intuitive handling. The directory structure is<br />

always in line with the physical production layout, even<br />

complex systems can be understood at a glance.<br />

Secure and flexible management of distributed control<br />

concepts<br />

ADDM can be flexibly used for every client/server and online<br />

storage system as well as for stand-alone machines. This<br />

means: Central data storage with maximum fault tolerance<br />

and availability as well as efficient archiving of all machine<br />

data.<br />

Thus: Fast feedback of the required version, if required.<br />

Checked, controlled, and documented archiving when<br />

several persons are working in parallel.<br />

Minimize downtimes<br />

You can rely on ADDM every time. Even when control components<br />

have to be replaced, for example. ADDM makes all the<br />

data available again immediately. With one click, without timeconsuming<br />

reparameterization and configuration, whether for<br />

individual programs or complete hard disk partitions, you will<br />

have the right data in the right place.<br />

5/278<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Function<br />

Controls fully mastered - across all program versions<br />

Backup can be time-driven, fully-automatic or manual. The data<br />

are available at all times and can be used for fast, simple<br />

disaster recovery in the event of a fault.<br />

System-active checking<br />

If, for example, data changes become obvious in an onlineoffline<br />

comparison, automatic backup can take place and/or the<br />

change can be notified by e-mail.<br />

Hot version backups<br />

The required version can be called up immediately from up to<br />

99 backups (regardless of archive versions).<br />

Total transparency and overview<br />

The practice-oriented structure is ideal not only for highlycomplex<br />

control systems but also for non-networked single<br />

machines – with a uniform user interface for all data types and<br />

formats. Checked, controlled and documented archiving when<br />

several persons are working in parallel.<br />

Totally Integrated Automation (TIA)<br />

ADDM has a unique way of managing your data uniformly in<br />

production.<br />

Optimum availability<br />

Reliable backup of all system and configuring data, including<br />

documentation and circuit diagrams, can be carried out<br />

manually or automatically with time control – for made-tomeasure<br />

distributed control concepts.<br />

Easy to handle<br />

No programming knowledge required – so no need for special<br />

training courses. With the use of communication modules, data<br />

can also be exchanged conveniently with controls via the<br />

MPI/PROFIBUS interface on TCP/IP.<br />

Contiguous archiving<br />

The machine data are fully versioned and archived and can be<br />

copied back at any time. This also includes the documentation.<br />

Operator-free data backup using the ADDM Agent<br />

Data backup of SINUMERIK controls can be time-driven or<br />

manual, without installing a user interface, using the<br />

ADDM Agent. The backup, load and compare functions can be<br />

performed remotely using the ADDM Client.


© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

ADDM - Data Management<br />

■ Integration ■ Ordering data Order No.<br />

Examples of components that are supported:<br />

ADDM<br />

S5 90U, 95U, 100U through AS511; 115U, 130W, 130WB, Software package<br />

135U, 155U through AS511 or SINEC H1<br />

Languages: English, German<br />

S7 S7-300, S7-400, WIN AC, WIN AC RTX<br />

ADDM Single User<br />

C7 C7-623, C7-626, C7-633, C7-634, C7-635 OP Mono, For <strong>PC</strong>/PG with Windows XP<br />

C7-635 TP B Mono<br />

Single license with CD-ROM 6BQ3 030-1AA30-3AD0<br />

NCU<br />

MCU<br />

SINUMERIK 840D powerline/840Di/810D powerline<br />

PLC data through S7 CPU<br />

MCU 172A, PLC data through S7 CPU<br />

of current software version<br />

Trial license with CD-ROM<br />

of current software version<br />

Single user upgrade<br />

6BQ3 030-1AA70-3AD0<br />

6BQ3 030-1AB13-3AD0<br />

<strong>PC</strong>IN PHG, OP 030, MMC 100, MMC 100.2<br />

ADDM Client<br />

HMI DOS DOS package for OP 031<br />

For <strong>PC</strong>/PG with Windows XP<br />

CPs<br />

OPs<br />

CP342-5, CP343-1,CP443-1, CP443-5<br />

OP7, OP15, OP17, OP27, OP37,<br />

OP 170B, OP 120, OP 270<br />

Single license<br />

without data carrier<br />

Single license with CD-ROM<br />

of current software version<br />

D 6BQ3 030-1AA20-1AC0<br />

6BQ3 030-1AA10-0AD0<br />

MPs MP270, MP370<br />

Client upgrade from V5.x to V6.2 6BQ3 030-1AB11-3AD0<br />

TDs/TPs TD17, TP27, TP37, TP 170A, TP 170B, TP 270,<br />

on CD-ROM<br />

TP 170 Micro, TP 170 Color<br />

ADDM Server<br />

Serial<br />

Drives<br />

Path<br />

V.24 interface (RS 232 C)<br />

SIMODRIVE 611 universal HRS/universal E HRS/<br />

digital via NCU,<br />

SIMODRIVE POSMO A/CD/CA/SI<br />

Directory/file<br />

For server <strong>PC</strong> with Windows XP<br />

and Windows 2003 Server<br />

Single license with CD-ROM<br />

of current software version<br />

Server upgrade from V5.x to<br />

V6.2 on CD-ROM<br />

6BQ3 030-1AA00-3AD0<br />

6BQ3 030-1AB10-3AD0<br />

HD Complete hard disks or hard disk partitions<br />

ADDM Agent<br />

For SINUMERIK <strong>PC</strong>U with<br />

HMI-Advanced<br />

Single license<br />

without data carrier<br />

D 6BQ3 030-1AA00-1AB0<br />

Single license with CD-ROM<br />

of current software version<br />

6BQ3 030-4AA00-0AD0<br />

Agent upgrade from V1.x to V1.3<br />

on CD-ROM<br />

6BQ3 030-1AB12-3AD0<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

■ More information<br />

Additional information is available on the Internet at:<br />

www.siemens.com/addm<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/279<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

DC UPS uninterruptible power supplies<br />

■ Overview<br />

The uninterruptible power supply DC with battery modules<br />

consists of DC UPS modules with 6 A, 15 A, or 40 A output<br />

current and the battery modules 1.2 Ah, 3.2 Ah, 7 Ah and 12 Ah<br />

(contains lead-acid batteries with corrosion-resistant leadcalcium<br />

high-performance grid plates and fiber-glass mat) and<br />

2.5 Ah (contains high-purity lead-acid "high-temperature<br />

batteries").<br />

The maintenance-free SITOP UPS500 with capacitors as energy<br />

storage units is especially well suited for use at high ambient<br />

temperatures. Another advantage of these high-capacity<br />

double-layer capacitors is the shorter charge times.<br />

For flexible use, there is the SITOP UPS500S - 15 A basic unit in<br />

2.5 kW and 5 kW versions. A maximum of 3 SITOP<br />

UPS501S expansion modules with 5 kW can be connected in<br />

parallel to increase the buffer times. The IP65 version<br />

SITOP UPS500P disposes of capacitors for 5 or 10 kW and<br />

provides up to 7 A of output current.<br />

DC UPS software<br />

SITOP DC UPS V3 software monitoring and configuration window<br />

5/2<strong>80</strong><br />

Backup module<br />

Expansion module with electrolyte<br />

capacitors for bridging temporary power<br />

failures. Can be combined with SITOP<br />

modular.<br />

Selection criteria:<br />

Low-cost protection against power<br />

failures for max. 3 seconds<br />

Supports the power supply unit when there<br />

is a temporary increased power demand<br />

High load current up to 40 A<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

DC UPS module with maintenance-free<br />

lead-gel batteries for energy storage.<br />

Bridging of power failures even for hours.<br />

Selection criteria:<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SITOP DC UPS module<br />

The 24 V power supply is maintained<br />

for a long time, e.g. in order to continue<br />

processes.<br />

High load current up to 40 A<br />

SITOP UPS500<br />

DC UPS with high-capacity double-layer<br />

capacitors. Bridging of power failures for<br />

severyl minutes.<br />

Selection criteria:<br />

Backup data and closing of applications<br />

within minutes.<br />

Absolutely maintenance-free<br />

High ambient temperatures up to 60°C<br />

No ventilation is required since no gas<br />

is emitted<br />

For distributed applications without<br />

control cabinet<br />

The uninterruptible power supplies DC are optionally available<br />

with USB interface or serial interface. All relevant messages<br />

about the status of the uninterruptible power supply DC can be<br />

transferred to a <strong>PC</strong> (e. g. SIMATIC I<strong>PC</strong>) via this interface.<br />

SITOP DC UPS software provides the user with a software tool<br />

that is extremely easy to operate and can be used to further<br />

process the signals sent from the uninterruptible power<br />

supply DC on the <strong>PC</strong>. In monitoring mode, the statuses of the<br />

uninterruptible power supply DC are visualized on the <strong>PC</strong>.<br />

Secure shutdown on power failure and automatic restart of the<br />

<strong>PC</strong> are supported. It is also possible to freely define responses<br />

to the different operating states of the uninterruptible power<br />

supply DC, permitting extremely flexible integration into a wide<br />

variety of applications.<br />

The software runs under the operating systems Windows 2000,<br />

Windows XP and Windows Vista. It is available as freeware on<br />

the SITOP homepage and can be downloaded free of charge.<br />

www.siemens.com/sitop<br />

G_<strong>ST</strong><strong>80</strong>_XX_00486


■ Overview<br />

By combining a DC UPS module with at least one 24 V battery<br />

module and a SITOP power supply unit, longer power failures<br />

can be bridged without any interruption.<br />

The combination is used for example in machine-tool building, in<br />

the textile industry, on all types of production lines and filling<br />

plants, and in conjunction with 24 V industrial <strong>PC</strong>s. This prevents<br />

the negative effects which often result from power failures.<br />

DC UPS modules: 6 A, 15 A, 40 A<br />

Selection table for battery modules and mains buffering times<br />

Load current Battery module<br />

1.2 Ah<br />

(6EP1935-6MC01)<br />

Battery<br />

module 3.2 Ah<br />

(6EP1935-6MD11)<br />

Important information for selecting the battery capacity:<br />

When the mains buffering times were determined, the<br />

discharge period of new or non-aged, completely charged<br />

battery modules with a battery temperature of not less than<br />

+25 °C up to the failure of the battery voltage at 21 V was used<br />

as a basis (with voltage drops in the DC UPS, approx.<br />

20.4 V DC remains for the loads).<br />

Aging of the batteries reduces the available battery capacity<br />

until the end of service life to typically around 50% of the<br />

original capacity value when new (1.2 Ah or 3.2 Ah or 7 Ah,<br />

etc.) and the internal resistance increases. When the message<br />

"Battery charge > 85%" appears, only around 50% x 85% =<br />

approx. 43% of the originally available capacity can be<br />

assumed at the end of the battery service life.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

DC UPS with battery modules<br />

Battery modules:<br />

1.2 Ah<br />

(contains lead-acid batteries with corrosion-resistant leadcalcium<br />

high-performance grid plates and fiberglass mat)<br />

3.2 Ah<br />

(contains lead-acid batteries with corrosion-resistant leadcalcium<br />

high-performance grid plates and fiberglass mat)<br />

7 Ah<br />

(contains lead-acid batteries with corrosion-resistant leadcalcium<br />

high-performance grid plates and fiberglass mat)<br />

12 Ah<br />

(contains lead-acid batteries with corrosion-resistant leadcalcium<br />

high-performance grid plates and fiberglass mat)<br />

2.5 Ah<br />

(contains "high-temperature battery" type pure lead)<br />

Battery module 7 Ah<br />

(6EP1935-6ME21)<br />

Battery module<br />

12 Ah<br />

(6EP1935-6MF01)<br />

1A 30 min 2.5 h 6 h 11 h 2h<br />

2A 11 min 45 min 2.5 h 5h 45 min<br />

3A 4min 25 min 1.5 h 3h 30 min<br />

4A 2min 20 min 45 min 2h 20 min<br />

6A 1min 10 min 30 min 1h 13 min<br />

8A - 4min 20 min 40 min 9min<br />

10 A - 1.5 min 15 min 30 min 7min<br />

12 A - 1min 10 min 25 min 5.5 min<br />

14 A - 50 s 8min 20 min 4.5 min<br />

16 A - 40 s 6min 15 min 4min<br />

20 A - - 2min 11 min -<br />

At battery temperatures below +25 °C, the available capacity<br />

is further reduced by approx. 30% at +5 °C battery<br />

temperature to approx. 70% of approx. 43%, leaving only<br />

approx. 30% of the original capacity available.<br />

Accordingly, a significantly greater battery capacity must be<br />

selected when configuring the system: A drop to approx. 50%<br />

is compensated for by selecting 1/approx. 0.5 = approx.<br />

double the battery capacity (than required according to the<br />

table for the relevant load current and the relevant buffering<br />

time). Available capacity of approx. 43% is compensated for<br />

by selecting 1/approx. 0.43 = approx. 2.33 times the battery<br />

capacity. Available capacity of approx. 30% is compensated<br />

for by selecting 1/approx. 0.3 = approx. 3.33 times the battery<br />

capacity.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Battery module<br />

2.5 Ah<br />

(6EP1935-6MD31)<br />

5/281<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

DC UPS with battery modules<br />

■ Overview (continued)<br />

Recommendation:<br />

Instead of installing double the battery capacity to cope with<br />

battery aging, regular battery replacement midway through<br />

the expected service life (reduction of capacity to<br />

approx. 50%) can be more advisable for the following<br />

reasons: Until halfway (or slightly more than halfway) through<br />

the expected battery life the capacity does not fall below<br />

100%; if regularly replaced after half the expected life, only the<br />

single (instead of double) battery capacity is to be installed<br />

with regard to aging (→ neutral price with regard to battery<br />

module costs, but only half the space requirements).<br />

Replacement after half the battery life in particular eliminates<br />

the considerable range of variation of the residual capacity at<br />

the end of the battery life which is not defined in greater detail<br />

by battery manufacturers (after the full period, many batteries<br />

are above and many others are below the average 50%<br />

residual capacity, i.e. even if double the capacity is installed,<br />

the influence of aging at the end of the battery life is not<br />

reliably compensated, but only typically) → when replacing<br />

after half the expected life the projected bridging time is<br />

adhered to with considerably greater reliability.<br />

In the case of batteries that are stored in cool conditions (not<br />

above +25°C) and for no longer than 4 months, the following<br />

life expectancy, very dependent on the battery temperature, is<br />

to be assumed:<br />

Battery<br />

temperature<br />

5/282<br />

Drop to<br />

approx. 50% of<br />

residual<br />

capacity<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Recommendation:<br />

Replace<br />

(at 100% of<br />

residual<br />

capacity)<br />

all<br />

Alternative<br />

recommendation<br />

+20 °C 4years 2years<br />

+30 °C 2years 1year<br />

+40 °C 1year 0.5 years Install double<br />

capacity and<br />

replace 1 x per<br />

year<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

In normal cases (installation in the coolest location in the control<br />

cabinet at approx. +30 °C), the battery should be replaced with<br />

single installed battery capacity in accordance with the selection<br />

table after 1 year of operation!<br />

On the DC UPS module 40 A, at least 2 battery modules of<br />

7 Ah or higher must be connected in parallel for output<br />

currents > 30 A. When connecting battery modules in parallel,<br />

you must ensure identical capacity and aging.<br />

After a power failure, and at the end of the selected buffering<br />

time, the battery module is disconnected electronically from<br />

the loads as soon as the 24 V input voltage returns either<br />

automatically or by opening the On/Off control circuit, and<br />

quickly recharged with the charge current of the relevant<br />

DC UPS module (with I-U charge characteristic: initially<br />

constant current II for fast charging, and changeover to<br />

constant voltage U to maintain the charge when the battery is<br />

almost full).


■ Overview SITOP Power DC UPS module 6 A<br />

Compact design, only 50 mm wide<br />

Simple DIN rail mounting<br />

Completely uninterruptible mains buffering through immediate<br />

electronic connection of the battery as soon as the DC UPS<br />

input voltage falls below the value set by means of<br />

DIP switches.<br />

High level of safety and availability through monitoring of<br />

operational readiness, battery supply line, battery aging<br />

(message "Battery replacement necessary") and battery<br />

charge (message "Battery charged >85%")<br />

Support for automatic warm restart of industrial <strong>PC</strong>s through<br />

selectable shutdown characteristics.<br />

Optionally with serial or USB interface.<br />

SW tool available for download from<br />

www.siemens.com/sitop<br />

Executes under Windows NT4.0, Windows 2000 and<br />

Windows XP.<br />

■ Ordering data Order No.<br />

SITOP power DC UPS module<br />

6 A<br />

6EP1 931-2DC21<br />

With serial interface 6EP1 931-2DC31<br />

With USB interface 6EP1 931-2DC42<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

DC UPS module 6 A<br />

DC UPS module 15 A<br />

■ Overview SITOP Power DC UPS module 15 A<br />

Compact design, only 50 mm wide<br />

Completely uninterruptible mains buffering through immediate<br />

electronic connection of the battery as soon as the DC UPS<br />

input voltage falls below the value set by means of<br />

DIP switches.<br />

High level of safety and availability through monitoring of<br />

operational readiness, battery supply line, battery aging<br />

(message "Battery replacement necessary") and battery<br />

charge (message "Battery charged >85%")<br />

Support for automatic warm restart of industrial <strong>PC</strong>s through<br />

selectable shutdown characteristics.<br />

Optionally with serial or USB interface.<br />

SW tool available for download from<br />

www.siemens.com/sitop<br />

Executes under Windows NT4.0, Windows 2000 and<br />

Windows XP.<br />

■ Ordering data Order No.<br />

SITOP power DC UPS module<br />

15 A<br />

6EP1 931-2EC21<br />

With serial interface 6EP1 931-2EC31<br />

With USB interface 6EP1 931-2EC42<br />

SIPLUS PS DC UPS module<br />

15 A<br />

Uninterruptible power supplies<br />

without interface;<br />

Input: 24 V DC/16 A<br />

Output: 24 V DC/15 A<br />

Ambient temperature range:<br />

-25 ... +60 °C<br />

Coating of the printed circuit<br />

boards and the electronic<br />

components<br />

L 6AG1 931-2EC21-2AA0<br />

L: Subject to export regulations: AL: 9I999 and ECCN: N<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/283<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

DC UPS module 40 A<br />

Battery module 24 V/1.2 Ah<br />

■ Overview SITOP Power DC UPS module 40 A<br />

Compact design, only 102 mm wide<br />

Completely uninterruptible mains buffering through immediate<br />

electronic connection of the battery as soon as the DC UPS<br />

input voltage falls below the value set by means of<br />

DIP switches.<br />

High level of safety and availability through monitoring of<br />

operational readiness, battery supply line, battery aging<br />

(message "Battery replacement necessary") and battery<br />

charge (message "Battery charged >85%")<br />

Support for automatic warm restart of industrial <strong>PC</strong>s through<br />

selectable shutdown characteristics<br />

Optionally with USB interface.<br />

SW tool available for download from<br />

www.siemens.com/sitop<br />

Executes under Windows NT4.0, Windows 2000 and<br />

Windows XP.<br />

■ Ordering data Order No.<br />

SITOP power DC UPS module<br />

40 A<br />

6EP1 931-2FC21<br />

With USB interface 6EP1 931-2FC42<br />

SIPLUS PS DC UPS module<br />

40 A<br />

Uninterruptible power supplies<br />

without interface;<br />

Input: 24 V DC/43 A<br />

Output: 24 V DC/40 A<br />

Ambient temperature range:<br />

-25 ... +60 °C<br />

Coating of the printed circuit<br />

boards and the electronic<br />

components<br />

5/284<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6AG1 931-2FC21-7AA0<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Overview SITOP Power Battery module 24 V/1.2 Ah<br />

Battery module for DC UPS module 6 A<br />

Contains two maintenance-free, closed lead-acid batteries<br />

(from the same lot) which are installed in a holder and<br />

connected in series with corrosion-resistant lead-calcium<br />

high-performance grid plates and glass fiber<br />

Completely prewired with battery retainer and terminals<br />

Low self-discharge rate of approximately 3% per month<br />

(at +20 °C)<br />

■ Ordering data Order No.<br />

SITOP power,<br />

battery module 24 V/1.2 Ah<br />

For DC UPS module 6 A<br />

A 6EP1 935-6MC01<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H


■ Overview SITOP Power Battery module 24 V/2.5 Ah<br />

High-temperature battery module for DC UPS module 6 A and<br />

15 A<br />

Contains two maintenance-free, closed pure lead-acid<br />

batteries (from the same lot), which are installed in a holder<br />

and connected in series<br />

Completely prewired with battery retainer and terminals<br />

Low self-discharge rate of approximately 3% per month<br />

(at +20 °C)<br />

■ Ordering data Order No.<br />

Battery module SITOP power, 6EP1 935-6MD31<br />

24 V/2.5 Ah<br />

For DC UPS module 15 A<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

Battery module 24 V/2.5 Ah<br />

Battery module 24 V/3.2 Ah<br />

■ Overview SITOP Power Battery module 24 V/3.2 Ah<br />

Battery module for DC UPS module 6 A and 15 A<br />

Contains two maintenance-free, closed lead-acid batteries<br />

(from the same lot) which are installed in a holder and<br />

connected in series with corrosion-resistant lead-calcium<br />

high-performance grid plates and glass fiber<br />

Complete with battery retainer and terminals<br />

Low self-discharge rate of approximately 3% per month<br />

(at +20 °C)<br />

■ Ordering data Order No.<br />

SITOP power,<br />

6EP1 935-6MD11<br />

battery module 24 V/3.2 Ah<br />

for DC UPS module 15 A<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/285<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

Battery module 24 V/7 Ah<br />

Battery module 24 V/12 Ah<br />

■ Overview SITOP Power Battery module 24 V/7 Ah<br />

Battery module for DC UPS module 6 A, 15 A and DC UPS<br />

module 40 A (for > 30 to 40 A, 2 units are required in parallel)<br />

Contains two maintenance-free, closed lead-acid batteries<br />

(from the same lot) which are installed in a holder and<br />

connected in series with corrosion-resistant lead-calcium<br />

high-performance grid plates and glass fiber<br />

Completely pre-wired with terminals and battery retainer<br />

Low self-discharge rate of approximately 3% per month<br />

(at +20 °C)<br />

■ Ordering data Order No.<br />

SITOP power,<br />

6EP1 935-6ME21<br />

battery module 24 V/7 Ah<br />

for DC UPS module 6 A, 15 A and<br />

40 A<br />

5/286<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Overview SITOP Power Battery module 24 V/12 Ah<br />

Battery module for DC UPS module 6 A, 15 A and DC UPS<br />

module 40 A (for > 30 to 40 A, 2 units are required in parallel)<br />

Contains two maintenance-free, closed lead-acid batteries<br />

(from the same lot) which are installed in a holder and<br />

connected in series with corrosion-resistant lead-calcium<br />

high-performance grid plates and glass fiber<br />

Completely pre-wired with terminals and battery retainer<br />

Low self-discharge rate of approximately 3% per month<br />

(at +20 °C)<br />

■ Ordering data Order No.<br />

SITOP power,<br />

6EP1 935-6MF01<br />

battery module 24 V/12 Ah<br />

for DC UPS module 6 A, 15 A and<br />

40 A


■ Overview<br />

Uninterruptible power supplies normally store the electrical<br />

energy in lead-acid batteries. Temperatures such as those<br />

prevalent in control cabinets considerably shorten the service<br />

life of the battery, however, and the batteries must be replaced<br />

on a regular basis – annually at an ambient temperature of 40 °C,<br />

for example. The innovative SITOP UPS500, however, is based<br />

on absolutely maintenance-free capacitors with a long service<br />

life. Even at temperatures of 50 °C they still have more than <strong>80</strong>%<br />

of their capacity after 8 years. This means that the energy<br />

storage unit does not need to be replaced. Because the capacitors<br />

do not emit any gas, the control cabinet does not have to be<br />

ventilated.<br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

DC UPS with capacitors<br />

Another advantage is the significantly shorter charging times of<br />

the double-layer capacitors, which ensure that the buffer is<br />

ready very quickly after loss of power.<br />

The IP65 version SITOP UPS500P has capacitors for 5 or 10 kW<br />

and supplies up to 7 A output current. The oblong metal<br />

enclosure is also suitable for installing on support arm systems.<br />

Selection table SITOP UPS500 (optional with SITOP UPS501S expansion module) and mains buffering times<br />

Buffering and charging times<br />

SITOP UPS500S/501S configurations UPS500P<br />

Basic unit 2.5 kW 5kW 2.5 kW 5kW 2.5 kW 5kW 2.5 kW 5kW 5kW 10 kW<br />

Expansion<br />

modules<br />

- - 1×5kW 1×5kW 2×5kW 2×5kW 3×5kW 3×5kW - -<br />

Total energy 2.5 kW 5kW 7.5 kW 10 kW 12.5 kW 15 kW 17.5 kW 20 kW 5kW 10 kW<br />

Load<br />

current<br />

Buffer times<br />

0.5 A 134 s 236 s 390 s 478 s 632 s 748 s 851 s 1007 s 284 s 647 s<br />

0.8 A 90 s 167 s 266 s 346 s 440 s 527 s 5<strong>80</strong> s 706 s 190 s 435 s<br />

1A 75 s 138 s 219 s 296 s 365 s 414 s 490 s 572 s 153 s 351 s<br />

2A 38 s 76 s 122 s 156 s 203 s 230 s 265 s 306 s <strong>80</strong> s 152 s<br />

3A 26 s 52 s 82 s 106 s 136 s 159 s 186 s 213 s 53 s 108 s<br />

4A 19 s 39 s 61 s 81 s 101 s 120 s 139 s 160 s 40 s 84 s<br />

5A 15 s 31 s 49 s 65 s 81 s 95 s 111 s 130 s 30 s 68 s<br />

6A 12 s 26 s 40 s 55 s 67 s <strong>80</strong> s 94 s 106 s 25 s 57 s<br />

7A 10 s 21 s 34 s 47 s 58 s 69 s 81 s 82 s 21 s 49 s<br />

8A 8s 18 s 29 s 40 s 50 s 59 s 69 s 79 s - -<br />

10 A 6s 15 s 23 s 32 s 39 s 47 s 54 s 62 s - -<br />

12 A 4s 12 s 19 s 26 s 32 s 38 s 44 s 52 s - -<br />

15 A 3s 9s 14 s 20 s 25 s 30 s 35 s 40 s - -<br />

Charging<br />

current<br />

Charging times<br />

2A 54 s 120 s 158 s 223 s 263 s 318 s 355 s 417 s 130 s 360 s<br />

1A 110 s 205 s 311 s 425 s 503 s 625 s 695 s 816 s - -<br />

Important information for selecting the energy storage units:<br />

When the mains buffering times were determined, the discharge<br />

period of new or non-aged, completely charged capacitors was<br />

used as a basis. At a continuous ambient temperature of +50 °C,<br />

a loss of capacity of approx. 20% must be considered after a<br />

service life of 8 years.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/287<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

SITOP UPS500S<br />

■ Overview<br />

Basic device 15 A, SITOP UPS500S<br />

Compact design, only 120 mm wide<br />

Two versions with integrated energy storage units: 2.5 kW<br />

or 5 kW<br />

Can be expanded easily using a user-friendly plug-in system<br />

with the expansion module 5 kW<br />

Absolutely uninterruptible bridging of power failures, as soon<br />

as the DC UPS input voltage falls below the value set by the<br />

DIP switches<br />

High level of safety and availability through monitoring of<br />

operational readiness, and monitoring of the capacitor charge<br />

(message "> 85% charged")<br />

Support for automatic warm restart of industrial <strong>PC</strong>s through<br />

selectable shutdown characteristics<br />

With USB interface<br />

5/288<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Maintenance-free power supply in the form of a combination of a<br />

basic module and an expansion module<br />

SITOP UPS501S expansion module<br />

Additional energy storage (5 kW)<br />

Up to 3 expansion modules can be connected to a<br />

SITOP UPS500S to extend the buffer times<br />

Compact design, only 70 mm wide<br />

Can be easily connected to SITOP UPS500S via a userfriendly<br />

plug-in system<br />

Complete with balancing and safety circuits<br />

Can be snapped onto standard mounting rail<br />

EN 60715 35x7.5/15<br />

Dimensions (W x H x D) in mm: approx. 70 x 125 x 125<br />

Weight: approx. 0.7 kg<br />

■ Ordering data Order No. Order No.<br />

SITOP UPS500S<br />

SITOP UPS501S<br />

DC UPS basic device 15 A with<br />

2.5kW 6EP1 933-2EC41<br />

Expansion module 5 kW for<br />

connecting to the basic device<br />

6EP1 935-5PG01<br />

5kW 6EP1 933-2EC51<br />

Connector set consisting of<br />

connector for input and output<br />

and an assembled USB cable<br />

(2 m in length)<br />

6EP1 975-2ES00


■ Overview<br />

The SIMATIC <strong>PC</strong> accessories include various input and output<br />

devices, keyboards and printers.<br />

printers and<br />

keyboards.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

Input and output devices<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/289<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

T 2240/9<br />

■ Overview<br />

The T 2240/9 is a rugged 9-needle printer for the medium performance<br />

range and is suitable for continuous use in rough<br />

industrial environments.<br />

The strength of the T 2240/9 is its versatility. The T 2240/9 is a<br />

cost-effective printer for professional use.<br />

5/290<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Economically priced form printer with 9-needle printing head<br />

Printing volume up to 14,000 pages/month<br />

Printing speed up to 500 characters/second<br />

Flexible paper input by optional linear tractor<br />

High impact for up to 6 drafts (1 + 5)<br />

22 barcodes, OCR-A and OCR-B<br />

Particularly compact for small space requirements<br />

■ Ordering data Order No.<br />

Standard configuration<br />

T 2240/9<br />

9 pins, DIN A4 (power supply is<br />

not switchable: for operation with<br />

230 V only)<br />

Accessories<br />

■ More information<br />

6GF6 520-1LL<br />

Interfaces<br />

RS 232C 6GF6 520-2HA<br />

RS 232/TTY 6GF6 520-2LA<br />

Information on possible uses, technical details, other printer<br />

products and additional components from the company<br />

DASCOM Europe GmbH can be found on the Internet at<br />

www.dascom.com or is available from:<br />

DASCOM Europe GmbH<br />

Mr. Wolfgang Wagner<br />

Tel.: +49 (0)7121 9943 097<br />

Fax: +49 (0)7121 9943 098<br />

E-Mail: wwagner@dascom.com<br />

Website: www.dascom.com


■ Overview<br />

The T 2240/24 is a rugged 24-needle printer for the medium<br />

performance range (14,000 pages/month) and is suitable for<br />

continuous use in rough industrial environments.<br />

The strength of the T 2240/24 is its versatility. The T 2240/24 is<br />

a cost-effective printer for professional use.<br />

■ Benefits<br />

Low-cost form printer with 24-pin print head<br />

Print volumes up to 14,000 pages/month<br />

Print speed up to 440 characters per second<br />

Flexible paper input via optional push tractor<br />

22 barcodes, OCR-A and OCR-B<br />

Especially compact design with small footprint<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

■ Ordering data Order No.<br />

Standard configuration<br />

T 2240/24<br />

24 pins, DIN A4 (power supply is<br />

not switchable: for operation with<br />

230 V only)<br />

Accessories<br />

6GF6 520-1LM<br />

Interfaces<br />

RS 232C 6GF6 520-2HA<br />

RS 232/TTY 6GF6 520-2LA<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

T 2240/24<br />

■ More information<br />

Information on possible uses, technical details, other printer<br />

products and additional components from the company<br />

DASCOM Europe GmbH can be found on the Internet at<br />

www.dascom.com or is available from:<br />

DASCOM Europe GmbH<br />

Mr. Wolfgang Wagner<br />

Tel.: +49 (0)7121 9943 097<br />

Fax: +49 (0)7121 9943 098<br />

E-Mail: wwagner@dascom.com<br />

Website: www.dascom.com<br />

5/291<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

T 2340/24<br />

■ Overview<br />

The T 2340/24 is a rugged 24-needle printer for paper size<br />

DIN A3 diagonal. It is designed for the medium performance<br />

range (14,000 pages/month) and is suitable for continuous use<br />

in rough industrial environments.<br />

The strength of the T 2340/24 is its versatility. The T 2340/24 is<br />

a cost-effective printer for professional use.<br />

■ Benefits<br />

Economically priced form printer with 24-needle printing head<br />

Printing volume up to 14,000 pages/month<br />

Printing speed up to 440 characters/second<br />

Flexible paper input by continuous tractor and manual single<br />

sheet feed<br />

Optional, automatic front feed<br />

22 barcodes, OCR-A and OCR-B<br />

Particularly compact for small space requirements<br />

5/292<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Ordering data Order No.<br />

Standard configuration<br />

T 2340/24<br />

6GF6 520-1LN<br />

24 pins, DIN A3 transverse<br />

(power supply is not switchable:<br />

for operation with 230 V only)<br />

Accessories<br />

Interfaces<br />

RS 232C 6GF6 520-2HA<br />

RS 232/TTY 6GF6 520-2LA<br />

■ More information<br />

Information on possible uses, technical details, other printer<br />

products and additional components from he company<br />

DASCOM Europe GmbH can be found on the Internet at<br />

www.dascom.com or is available from:<br />

DASCOM Europe GmbH<br />

Mr. Wolfgang Wagner<br />

Tel.: +49 (0)7121 9943 097<br />

Fax: +49 (0)7121 9943 098<br />

E-Mail: wwagner@dascom.com<br />

Website: www.dascom.com


■ Overview<br />

The 2150 is a multifunctional 24-pin printer for paper sizes up to<br />

DIN A4. It is designed for high performance (up to 26,000 pages<br />

per month), and is suitable for continuous use under harsh<br />

industrial conditions.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

■ Ordering data Order No.<br />

Standard configuration<br />

2150<br />

24 pins, DIN A4 (switchable<br />

power supply: 110 V/230 V)<br />

Accessories<br />

A 6GF6 520-1LD<br />

Interfaces<br />

RS 232/TTY 6GF6 520-2LB<br />

Ethernet (10/100 Mbit/s) A 6GF6 520-2LC<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

■ More information<br />

Information on possible uses, technical details, other printer<br />

products and additional components from the company<br />

DASCOM Europe GmbH can be found on the Internet at<br />

www.dascom.com or is available from:<br />

DASCOM Europe GmbH<br />

Mr. Wolfgang Wagner<br />

Tel.: +49 (0)7121 9943 097<br />

Fax: +49 (0)7121 9943 098<br />

E-Mail: wwagner@dascom.com<br />

Website: www.dascom.com<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

2150<br />

5/293<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

2250<br />

■ Overview<br />

The 2250 is a multifunctional 24-pin printer for paper sizes up to<br />

DIN A3 diagonal. It is designed for high performance (up to<br />

26,000 pages per month), and is suitable for continuous use<br />

under harsh industrial conditions.<br />

■ Benefits<br />

Multifunctional needle printer for various applications<br />

Printing volume up to 26,000 pages/month<br />

Printing speed up to 650 characters/second<br />

Flexible paper input by linear tractor and single sheet feed<br />

Extensive automatic functions for unsupervised printing jobs<br />

Rugged design<br />

For processing paper in sizes up to DIN A3 diagonal<br />

5/294<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Ordering data Order No.<br />

Standard configuration<br />

2250<br />

24 pins, DIN A3 in landscape<br />

format (switchable power<br />

supply: 110 V/230 V)<br />

Accessories<br />

6GF6 520-1LE<br />

Interfaces<br />

RS 232/TTY 6GF6 520-2LB<br />

Ethernet (10/100 Mbit/s) A 6GF6 520-2LC<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

■ More information<br />

Information on possible uses, technical details, other printer<br />

products and additional components from the company<br />

DASCOM Europe GmbH can be found on the Internet at<br />

www.dascom.com or is available from:<br />

DASCOM Europe GmbH<br />

Mr. Wolfgang Wagner<br />

Tel.: +49 (0)7121 9943 097<br />

Fax: +49 (0)7121 9943 098<br />

E-Mail: wwagner@dascom.com<br />

Website: www.dascom.com


■ Overview<br />

■ Technical specifications<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

SIMATIC <strong>PC</strong> keyboard<br />

The original SIMATIC <strong>PC</strong> keyboard is the ideal input medium for<br />

your SIMATIC <strong>PC</strong>. It combines the convenience of an office<br />

keyboard with the ruggedness of an industrial device. The<br />

SIMATIC <strong>PC</strong> keyboard is available with a USB connection and<br />

German/international layout. It is optionally available with an<br />

integrated USB hub for 4 other USB devices.<br />

SIMATIC <strong>PC</strong> keyboard<br />

Description SIMATIC <strong>PC</strong> keyboard SIMATIC <strong>PC</strong> keyboard, 4 USB hubs, ger/int<br />

Layout MF2, 105 keys, German/international MF2, 105 keys, German/international<br />

Dimensions (L x W x H) in mm 470 x 195 x 44 458 x 195 x 42<br />

Weight, approx. 1400 g 1140 g<br />

Connecting cable<br />

Temperature<br />

Length 1.75 m, USB plug Length 1.75 m, USB plug<br />

During operation 0... +50 °C 0 ... +50 °C<br />

Storage -20 ... +60 °C -20 ... +60 °C<br />

Current consumption - max. 500 mA<br />

Current delivery - max. 100 mA per downstream port<br />

Transmission rate - Up to 12 Mbit/s<br />

Approvals FCC, cURus, GS, CE, c-tick, GO<strong>ST</strong>-R FCC, cURus, GS, CE, c-tick, GO<strong>ST</strong>-R, VCCI<br />

■ Ordering data Order No. Order No.<br />

SIMATIC <strong>PC</strong> keyboard 6ES7 648-0CB00-0YA0<br />

SIMATIC <strong>PC</strong> keyboard, 4x USB A 6ES7 648-0CD00-0YA0<br />

German/international, USB<br />

German/international, USB<br />

connection incl. USB-PS2<br />

connection<br />

adapter<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/295<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

IP65 membrane keyboard, desktop version<br />

■ Overview<br />

The desktop version of the IP65 membrane keyboard is ideal for<br />

use in industrial areas in which a high degree of protection (IP65)<br />

is required. The keyboard is equipped with a touchpad.<br />

5/296<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Jet-proof<br />

Rugged front due to reinforced front membrane (150 µm)<br />

made of resistant polyester<br />

Integrated touchpad<br />

UL/CSA listed<br />

■ Ordering data<br />

Standard configuration<br />

IP65 membrane keyboard,<br />

desktop version with<br />

touchpad<br />

Order No.<br />

1) Available soon with USB plug<br />

1)<br />

With PS/2 connector<br />

German keyboard layout 6GF6 710-2AC<br />

International keyboard layout A 6GF6 710-2BC<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H


■ Overview<br />

The built-in version of the IP65 membrane keyboard is ideal for<br />

use in industrial areas in which a high degree of protection<br />

(IP65 at the front, IP54 at the rear) is required. The keyboard is<br />

specially designed for installation in 19" cabinets.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

■ Benefits<br />

IP65 membrane keyboard, 19" built-in version<br />

Jet-proof<br />

Extra-reinforced front membrane (1<strong>80</strong> µm) made of resistant<br />

polyester<br />

Touchpad or trackball (IP65 version)<br />

UL/CSA listed<br />

■ Ordering data Order No.<br />

Standard configuration<br />

IP65 membrane keyboard,<br />

19" built-in version<br />

For installation in 19" cabinets<br />

With touchpad<br />

- German keyboard layout 6GF6 710-3AE<br />

- International keyboard layout 6GF6 710-3BE<br />

With trackball<br />

- German keyboard layout 6GF6 710-3BF<br />

- International keyboard layout 6GF6 710-3BG<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/297<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

19" slide-in keyboard PS/2 with trackball<br />

■ Overview<br />

With its compact design and integrated trackball the new drawout<br />

keyboard is suitable in particular for industrial applications<br />

with limited space. This can be, for example, cubicles or mobile<br />

systems.<br />

The draw-out keyboard is supplied in combination with a drawer.<br />

5/298<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Jet-proof<br />

Small space requirement<br />

High reliability<br />

Integrated trackball<br />

Flat design<br />

■ Ordering data<br />

Standard configuration<br />

19“ draw-out keyboard with<br />

trackball<br />

Order No.<br />

German key layout A 6GF6 710-3BJ<br />

International key layout A 6GF6 710-3BK<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H


■ Overview<br />

Even with the mouse we offer you more than the standard:<br />

Optical wheel mouse for use with USB or PS/2 interface.<br />

Interfaces: USB and PS/2 (via adapter)<br />

Operating systems: Microsoft Windows XP, 2000, ME, 98,<br />

Windows NT4<br />

Connection cable: Length 1.83 m, USB plug<br />

Approvals corresponding to office environment:<br />

- FCC Declaration of Conformity (USA)<br />

- UL and cUL Notice of Approval (USA and Canada)<br />

- ICES-003 report on file (Canada)<br />

- TÜV-GS Certificate (Germany)<br />

- CE Declaration of Conformity<br />

- Safety and EMC (EU)<br />

- GO<strong>ST</strong> Certificate (Russia)<br />

- VCCI Certificate (Japan)<br />

- ACA/MED Declaration of Conformity (Australia and<br />

New Zealand)<br />

- BSMI Certificate (Taiwan)<br />

- MIC Certificate (Korea)<br />

- NOM Certificates (Mexico)<br />

- CB Scheme Certificate (International)<br />

- WHQL (International) ID: 866988<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

■ Benefits<br />

SIMATIC <strong>PC</strong> mouse<br />

Minimized overhead through safe and reliable operation with<br />

SIMATIC <strong>PC</strong>/PG<br />

■ Ordering data Order No.<br />

SIMATIC <strong>PC</strong> mouse 6ES7 790-0AA01-0XA0<br />

Optical wheel mouse,<br />

USB interface,<br />

incl. PS/2 adapter<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/299<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

Operating channel extensions (active)<br />

■ Overview<br />

If the distance between computer and operator panel is greater<br />

than 2 m, you will require an operating channel extension (BKV).<br />

The BKV is an active operating channel extension for use in<br />

harsh industrial environments. It is available in the following<br />

lengths:<br />

BKV 2520: 20 m<br />

BKV 2550: 50 m<br />

Note:<br />

Every operating channel extension has PS/2 ports for mouse<br />

and keyboard. An additional video cable of corresponding<br />

length is required for the monitor.<br />

5/300<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Application<br />

The operator communication channel extensions are for mouse<br />

and keyboards and can be used in the industrial sector.<br />

■ Design<br />

PS/2 ports for mouse and keyboard<br />

Length: 20 m or 50 m<br />

■ Ordering data Order No.<br />

Standard configuration<br />

BKV active, operating channel<br />

extension active<br />

PS/2 ports<br />

BKV 2520<br />

20 m long 6GF6 9<strong>80</strong>-0KC<br />

BKV 2550<br />

50 m long 6GF6 9<strong>80</strong>-0KE


■ Overview<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Expansion components and accessories<br />

MA<strong>ST</strong>ERGUARD power supply<br />

Standard configuration<br />

MA<strong>ST</strong>ERGUARD UPS Series El-19<br />

MA<strong>ST</strong>ERGUARD UPS<br />

The A-19 and EI-19 series of Masterguard offer effective online<br />

protection against all kinds of power supply disturbances<br />

Genuine online operating principle, i.e. complete<br />

disconnection of the load from the irregularities of the line<br />

EI-19<br />

Output: 6000 VA<br />

Battery pack for MA<strong>ST</strong>ERGUARD Series EI-19<br />

BPEI-19<br />

power supply<br />

Accessories<br />

19" compact modules<br />

Simple operation and functional indication of operating states<br />

and load stages<br />

Slide rail unit 3 HU 330-5<strong>80</strong> mm<br />

Slide rail unit 3 HU 575-855 mm<br />

MA<strong>ST</strong>ERGUARD UPS Series A-19/EI-19<br />

ManageUPS SNMP adapter card<br />

Permanent double-converter technology evens out any MopUPS shutdown software<br />

irregularity in the power supply and offers totally uninterrupted<br />

protection<br />

Easily configurable for use in 19" cabinets thanks to battery<br />

for Intel operating systems (Windows, Linux, Solaris for Intel)<br />

for Risc operating systems (Solaris SPARC, HPUX, AIX)<br />

expansions and universal slide rail units<br />

■ More information<br />

With a height of just 2 HU for the A-19 series and 3 HU for the<br />

EI-19 series and with power-regulated fan and functional www.masterguard.de<br />

display, these units are ideal where space is limited.<br />

For communication, a choice can be made between serial and<br />

USB interface and, in addition, a network connection of the<br />

Sales contact:<br />

MA<strong>ST</strong>ERGUARD GmbH<br />

UPS can be set up by means of an SNMP plug-in card for the<br />

communication slot.<br />

Standard configuration<br />

MA<strong>ST</strong>ERGUARD UPS Series A-19<br />

A700-19<br />

Mr. Willi Brinkmann<br />

Tel: +49 (0)9131 6300 248<br />

Fax: +49 (0)9131 6300 271<br />

E-mail: willi.brinkmann@masterguard.de<br />

Output: 700 VA; integrated battery: 6 min.<br />

Information hotline: +49 (0)1<strong>80</strong>-532 37 51<br />

A1000-19<br />

Output: 1000 VA; integrated battery: 7 min.<br />

A2000-19<br />

Service contact:<br />

MA<strong>ST</strong>ERGUARD GmbH<br />

Output: 2000 VA<br />

Mr. Alexander Zink<br />

A3000-19<br />

Output: 3000 A<br />

Battery pack for MA<strong>ST</strong>ERGUARD Series A-19<br />

BPA 1000-19<br />

Phone: +49 (0)9131 6300 218<br />

Fax: +49 (0)9131 6300 281<br />

E-mail: alexander.zink@masterguard.de<br />

for UPS A1000-19 (max. 2 BP)<br />

BPA 3000-19<br />

for UPS A2000-19 (max. 5 BP) and UPS A3000-19 (max. 5 BP)<br />

Accessories<br />

Slide rail unit 2 HU 330-5<strong>80</strong> mm<br />

Slide rail unit 2 HU 575-855 mm<br />

Support line: +49 (0)1<strong>80</strong>-522 10 96<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/301<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Communication — Industrial Ethernet<br />

Connection options to SIMATIC I<strong>PC</strong>s<br />

■ Overview<br />

The operating systems listed in the table refer exclusively to the<br />

communication products specified! Please refer to the<br />

Communication<br />

hardware<br />

Connection options of Industrial Ethernet CPs to PG/<strong>PC</strong>/I<strong>PC</strong><br />

5/302<br />

Communication<br />

software<br />

CPs and software for Industrial Ethernet<br />

CP 1613 A2<br />

(<strong>PC</strong>I 32 Bit)<br />

CP 1623<br />

(<strong>PC</strong>Ie x1)<br />

CP 1628<br />

(<strong>PC</strong>Ie x1)<br />

CP 1612 A2<br />

(<strong>PC</strong>I 32 Bit)<br />

SIMATIC PG/<strong>PC</strong><br />

with integral<br />

Ethernet<br />

interface<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Operating system environment of the<br />

communication software<br />

Windows 7 Professional /<br />

Ultimate<br />

Windows Server 2008 R2<br />

Windows Server 2008 +<br />

SP1/2<br />

Vista Business /<br />

Ultimate + SP1/2<br />

Windows XP Pro + SP3<br />

Windows Server 2003<br />

R2 / SP2<br />

description of the relevant I<strong>PC</strong> for the operating system that is<br />

available and has been released for that I<strong>PC</strong>.<br />

other operating systems<br />

SIMATIC Industrial <strong>PC</strong>/<br />

Field PG<br />

Field PG M3<br />

SIMATIC I<strong>PC</strong>847C<br />

SIMATIC I<strong>PC</strong>547C/D<br />

SIMATIC I<strong>PC</strong>627C<br />

SIMATIC I<strong>PC</strong>827C<br />

SIMATIC I<strong>PC</strong>427C<br />

Embedded Systems<br />

Op.<br />

sys.<br />

Windows XP Embedded +<br />

SP1/SP2/FP 2007<br />

SIMATIC<br />

Industrie-<strong>PC</strong><br />

HARDNET-IE S7<br />

(S7-1613) • • • • • • - - • • • • - • - • • -<br />

HARDNET-IE S7<br />

REDCONNECT 3) • • • • • • - - • • ○4)5) • - • - ○4)5) ○4)5) -<br />

S7 O<strong>PC</strong> Redundancy for<br />

Industrial Ethernet - • - - - - - - • • • • - • - • • -<br />

HARDNET-IE S7<br />

(S7-1613) • • • • • • - - • • ○5) • - • - ○5) ○5) -<br />

HARDNET-IE S7<br />

REDCONNECT 3) • • • • • • - - ○5) ○5) ○4)5) • - • - ○4)5) ○4)5) -<br />

S7 O<strong>PC</strong> Redundancy for<br />

Industrial Ethernet - • - - - - - - • • • • - • - ○5) • -<br />

HARDNET-IE S7<br />

(S7-1613) • • - - - - - - • • ○5) • - • - ○5) ○5) -<br />

HARDNET-IE S7<br />

REDCONNECT 3) • • - - - - - - ○5) ○5) ○4)5) • - • - ○4)5) ○4)5) -<br />

S7 O<strong>PC</strong> Redundancy for<br />

Industrial Ethernet - • - - - - - - • • • • - • - ○5) • -<br />

SOFTNET-IE S7 • • • • • • - - • • • • - • - • • -<br />

SOFTNET-IE S7 Lean • • • • • • - - • • • • - • - • • -<br />

SOFTNET-IE PG • • • • • • - - • • • • - • - • • -<br />

S7 O<strong>PC</strong> Redundancy for<br />

Industrial Ethernet - • - - - - - - • • • • - • - • • -<br />

SOFTNET-IE S7 • • • • • • - • • • • • • • • • • •<br />

SOFTNET-IE S7 Lean • • • • • • - • • • • • • • • • • •<br />

SOFTNET-IE PG • • • • • • - • • • • • • • • • • •<br />

S7 O<strong>PC</strong> Redundancy for<br />

Industrial Ethernet - • - - - - - • • • • • • • • • • •<br />

CPs and software for PROFINET<br />

CP 1616 1)<br />

(<strong>PC</strong>I 32 Bit)<br />

CP 1604 1)<br />

(<strong>PC</strong>I-104)<br />

SIMATIC PG/<strong>PC</strong><br />

with integral<br />

Ethernet<br />

interface<br />

HARDNET PN IO DK<br />

(DK-16xx PN IO) 1) • - - - • - ○ - ○ ○ ○ ○ - ○ - ○ ○ -<br />

HARDNET PN IO DK<br />

(DK-16xx PN IO) 1) • - - - • - ○ - - - - - ○2) ○ ○2) - - -<br />

SOFTNET PN IO • • • • • • - • • • • • • • • • • •<br />

1) Use of these CPs requires porting of the Development Kit DK-16xx PN IO to the relevant operating<br />

system environment. You can order the DK-16xx PN IO at www.siemens.com/simatic-net/<br />

dk16xx on the Internet. It contains sample software for Linux Suse 12 and Windows XP Professional.<br />

For IRT operation an exclusive interrupt is necessary; this is not available in all slots.<br />

The additional use of CP 1616/CP 1604 is not approved for SIMATIC Industrial <strong>PC</strong> versions and<br />

integrated PROFINET interface.<br />

2) possible with restrictions, if necessary, depending on memory expansion and processor capacity<br />

3) requires at least 2 <strong>PC</strong>I or 2 <strong>PC</strong>Ie slots (4-way redundancy requires 4 free <strong>PC</strong>I or 4 <strong>PC</strong>Ie slots!);<br />

hybrid configurations with CP 1613 A2 (<strong>PC</strong>I) and CP 1623 (<strong>PC</strong>Ie) are possible,<br />

depending on <strong>PC</strong> expansion<br />

4) without 4-way redundancy as there are only 2 slots<br />

5) depending on the slots of the selected <strong>PC</strong> version<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Notes<br />

- Please always note the supplementary conditions for the specified<br />

SIMATIC NET products that you can view on the Internet pages<br />

shown below.<br />

- for further details on XP embedded, see<br />

http://support.automation.siemens.com/WW/view/de/ 21661049<br />

- further details on system requirements and operating environments<br />

can be found in the Readme file of the communication products on<br />

the SIMATIC NET <strong>PC</strong> Software V8.1 CD<br />

- Updates and supplements to the catalog entries, as well as the above<br />

tables can be viewed at<br />

http://www.siemens.com/simatic-net/ik-info<br />

SIMATIC I<strong>PC</strong>427C,<br />

SIMATIC HMI I<strong>PC</strong>477C<br />

• -○<br />

SIMATIC HMI I<strong>PC</strong>677C<br />

SIMATIC I<strong>PC</strong>627C<br />

suitable<br />

not suitable<br />

suitable under<br />

certain conditions<br />

SIMATIC S7 modular<br />

Embedded Controller


■ Overview<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<br />

<br />

<strong>PC</strong>-based Automation<br />

Communication — Industrial Ethernet<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

CP 1604<br />

<strong>PC</strong>I-104 module for connecting <strong>PC</strong>I-104 systems to<br />

PROFINET IO<br />

Full/half duplex with autonegotiation<br />

With Ethernet real-time ASIC ERTEC 400<br />

Integrated 4-port real-time switch<br />

Communication services:<br />

- PROFINET IO controller and/or PROFINET IO device<br />

- Support of IRT in motion control applications<br />

High performance through direct memory access<br />

Integration in network management systems through the<br />

support of SNMP<br />

Comprehensive diagnostics possibilities for installation,<br />

start-up and operation of the module<br />

Powerful configuration tools are included in delivery of module<br />

5/303<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Communication — Industrial Ethernet<br />

CP 1604<br />

■ Ordering data Order No. Order No.<br />

CP 1604 communication<br />

6GK1 160-4AA00<br />

Accessories<br />

processor<br />

Connection board for CP 1604 A 6GK1 160-4AC00<br />

<strong>PC</strong>I-104 card (32-bit) with<br />

ASIC ERTEC 400 for connecting<br />

<strong>PC</strong>I-104 systems to PROFINET IO<br />

with 4-port real-time switch<br />

Connection board for CP 1604<br />

with four RJ45 sockets incl.<br />

connecting cable<br />

(RJ45); incl. IO-Base software for<br />

PROFINET IO-Controller and<br />

NCM <strong>PC</strong>; single license for one<br />

installation, runtime software,<br />

software and electronic manual<br />

on CD-ROM, Class A, for 32-bit<br />

Windows XP Professional; other<br />

operating systems by means of<br />

Power supply for CP 1604<br />

Redundant power supply for<br />

CP 1604 for operating the<br />

integrated 4-port switch of the<br />

CP 1604 with the <strong>PC</strong>-104 system<br />

switched off; includes connecting<br />

cable<br />

6GK1 160-4AP00<br />

DK-16xx PN IO Development Kit<br />

German/English<br />

CP 1604 Microbox Package 6GK1 160-4AU00<br />

DK-16xx PN IO development kit<br />

Software development kit for<br />

CP 1616/CP 1604;<br />

see<br />

www.siemens.com/<br />

simatic-net/dk16xx<br />

Package for implementing the<br />

CP 1604 in the<br />

SIMATIC Microbox <strong>PC</strong>;<br />

comprising the CP 1604,<br />

connection board, power supply<br />

and expansion racks for<br />

Microbox <strong>PC</strong>; for use with<br />

Development Kit DK-16xx PN IO;<br />

NCM <strong>PC</strong><br />

driver and IO-Base software for<br />

CP 1616/CP 1604 as PN IO<br />

controller and IO device in source<br />

code for transfer to other<br />

<strong>PC</strong>-based operating systems;<br />

including executable example<br />

code for SUSE Linux 10,<br />

Windows XP Professional and<br />

Windows 7<br />

IE TP Cord RJ45/RJ45<br />

TP cable 4 x 2 with 2 RJ45<br />

connectors<br />

0.5 m 6XV1 870-3QE50<br />

1 m 6XV1 870-3QH10<br />

2 m 6XV1 870-3QH20<br />

6 m 6XV1 870-3QH60<br />

10 m 6XV1 870-3QN10<br />

SCALANCE X204IRT<br />

Managed Industrial Ethernet<br />

switches;<br />

isochronous real time,<br />

LED diagnostics,<br />

error signaling contact with<br />

SET button,<br />

redundant power supply<br />

4 x 10/100 Mbit/s RJ45 ports<br />

6GK5 204-0BA00-2BA3<br />

5/304<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

A: Subject to export regulations: AL: N and ECCN: EAR99H


■ Overview<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<strong>PC</strong>I module for connecting <strong>PC</strong>s and SIMATIC PGs/<strong>PC</strong>s to<br />

PROFINET IO (Universal keyed 3.3 V and 5 V; 33 MHz/<br />

66 MHz; 32-bit, runs in 64-bit <strong>PC</strong>I-X systems)<br />

Full/half duplex with autonegotiation<br />

With Ethernet real-time ASIC ERTEC 400<br />

Integrated 4-port real-time switch<br />

Communication services:<br />

- PROFINET IO controller and/or PROFINET IO device<br />

- Support of IRT in motion control applications<br />

High performance through direct memory access<br />

Integration in network management systems through the<br />

support of SNMP<br />

Comprehensive diagnostics possibilities for installation,<br />

start-up and operation of the module<br />

Powerful configuration tools are part of the scope of delivery<br />

of the module<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<br />

<br />

<strong>PC</strong>-based Automation<br />

Communication — Industrial Ethernet<br />

■ Ordering data Order No.<br />

CP 1616 communication<br />

6GK1 161-6AA01<br />

processor<br />

<strong>PC</strong>I Card (32 bit; 3.3/5 V universal<br />

keyed) with ASIC ERTEC 400 for<br />

connecting <strong>PC</strong>s to PROFINET IO<br />

with 4-Port-Real-Time-Switch<br />

(RJ45); incl. IO Base Software for<br />

PROFINET IO Controller and<br />

NCM <strong>PC</strong>; single license for one<br />

installation, runtime software,<br />

software and electronic manual<br />

on CD-ROM, Class A, for 32 bit<br />

Windows XP Professional; other<br />

operating systems via Development<br />

Kit DK-16xx PN IO<br />

German/English<br />

Accessories<br />

DK-16xx PN IO development kit see<br />

www.siemens.com/<br />

Software development kit for<br />

simatic-net/dk16xx<br />

CP 1616/CP 1604;<br />

driver and IO-Base software for<br />

CP 1616/CP 1604 as PN IO<br />

controller and IO device in source<br />

code for transfer to other<br />

<strong>PC</strong>-based operating systems;<br />

including executable example<br />

code for SUSE Linux 10,<br />

Windows XP Professional and<br />

Windows 7<br />

IE TP Cord RJ45/RJ45<br />

TP cable 4 x 2 with 2 RJ45<br />

connectors<br />

0.5 m 6XV1 870-3QE50<br />

1 m 6XV1 870-3QH10<br />

2 m 6XV1 870-3QH20<br />

6 m 6XV1 870-3QH60<br />

10 m 6XV1 870-3QN10<br />

SCALANCE X204IRT 6GK5 204-0BA00-2BA3<br />

Managed Industrial Ethernet<br />

switches;<br />

isochronous real time,<br />

LED diagnostics,<br />

error signaling contact with<br />

SET button,<br />

redundant power supply<br />

4 x 10/100 Mbit/s RJ45 ports<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

CP 1616<br />

5/305<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Communication — Industrial Ethernet<br />

CP 1612 A2<br />

■ Overview<br />

<br />

5/306<br />

<br />

<br />

<br />

<br />

<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

<br />

<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<br />

<br />

<strong>PC</strong>I card (32 bit; 33 MHz/66 MHz; 3.3 V/5 V Universal Key)<br />

for the connection of PG/<strong>PC</strong> to Industrial Ethernet<br />

1 x 10/100/1000 Mbit/s RJ45 port, electrical<br />

Automatic data transmission rate detection (10/100/<br />

1000 Mbit/s), with autosensing and autocrossover function<br />

Communication services via<br />

-PROFINET<br />

- ISO or TCP/IP transport protocol<br />

- PG/OP communication<br />

- S7 communication<br />

- Open communication (SEND/RECEIVE)<br />

Designed for use in industrial environments<br />

The appropriate O<strong>PC</strong> servers and configuration tools are<br />

included in the scope of supply of the respective<br />

communication software.


<strong>PC</strong>-based Automation<br />

Communication — Industrial Ethernet<br />

■ Ordering data Order No. Order No.<br />

CP 1612 A2 communication<br />

processor<br />

<strong>PC</strong>I card (32 bit, 33 MHz/66 MHz;<br />

3.3 V/5 V universal keyed) for<br />

connection to Industrial Ethernet<br />

(10/100/1000 Mbit/s) with RJ45<br />

interface, incl. driver for 32-bit<br />

Windows XP Professional SP2/3,<br />

2003 R2 Server SP2, Vista<br />

Business/Ultimate SP1,<br />

Windows 2008 Server;<br />

German/English<br />

B 6GK1 161-2AA01<br />

SOFTNET Security Client V4<br />

Software for designing secure<br />

IP-based VPN connections from a<br />

programming device/<strong>PC</strong> to<br />

network segments which are<br />

secured by SCALANCE S in<br />

bridge mode;<br />

Single License for 1 installation,<br />

runtime software (German/<br />

English), configuring tool<br />

(German/English) and electronic<br />

manual on CD-ROM (German/<br />

English/French/Italian/Spanish)<br />

for 32-bit Windows, XP Professional<br />

+ SP1, SP2, SP3, Windows<br />

Vista Ultimate/Business<br />

6GK1 704-1VW04-0AA0<br />

SOFTNET PN IO<br />

Software for PROFINET IO<br />

Controller with O<strong>PC</strong> server and<br />

NCM <strong>PC</strong>, runtime software,<br />

software and electronic manual<br />

on CD-ROM, license key on<br />

USB flash drive, Class A,<br />

see page 5/314<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SOFTNET-IE S7 V8.1 see page 5/314<br />

Software for S7 and open communication,<br />

incl. PG/OP communication,<br />

O<strong>PC</strong> server and NCM <strong>PC</strong>,<br />

runtime software, software and<br />

electronic manual on CD-ROM,<br />

licence key on USB flash drive,<br />

class A<br />

SOFTNET-IE PG V8.1 see page 5/314<br />

Software for PG/OP communication,<br />

runtime software, software<br />

and electronic manual on<br />

CD-ROM, licence key on<br />

USB flash drive, class A<br />

IE TP Cord RJ45/RJ45<br />

TP cable 4 x 2 with 2 RJ45<br />

connectors<br />

0.5 m 6XV1 870-3QE50<br />

1 m 6XV1 870-3QH10<br />

2 m 6XV1 870-3QH20<br />

6 m 6XV1 870-3QH60<br />

10 m 6XV1 870-3QN10<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

CP 1612 A2<br />

5/307<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Communication — Industrial Ethernet<br />

CP 1613 A2<br />

■ Overview<br />

<br />

<strong>PC</strong>I card (32 bit; 33 MHz/66 MHz; 3.3 V/5 V universal key) with<br />

microprocessor for connection of PG/<strong>PC</strong> to Industrial Ethernet<br />

with 10/100 Mbit/s Autosensing/Autonegotiation<br />

Communication services using<br />

- Open IE communication via TCP/IP and UDP)<br />

- ISO transport protocol<br />

- PG/OP communication<br />

- S7 communication<br />

- Open communication (SEND/RECEIVE)<br />

15-pole ITP connection<br />

RJ45 connection<br />

Time synchronization<br />

ISO and TCP/IP transport protocol onboard<br />

SNMP-supported diagnostics<br />

The appropriate O<strong>PC</strong> server and configuration tools are<br />

included in the respective scope of supply of the<br />

communication software<br />

5/308<br />

<br />

<br />

<br />

<br />

<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

<br />

<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<br />

<br />

■ Ordering data Order No.<br />

CP 1613 A2 communication<br />

processor<br />

<strong>PC</strong>I card (32-bit, 33 MHz/66 MHz;<br />

3.3 V/5 V universal keyed) for<br />

connection to Industrial Ethernet<br />

(10/100 Mbit/s) with ITP and RJ45<br />

connection over HARDNET-IE S7/<br />

S7-1613 and S7-REDCONNECT,<br />

operating system support see<br />

software SIMATIC NET<br />

6GK1 161-3AA01<br />

HARDNET-IE S7 V8.1<br />

Software for S7 and open communication,<br />

incl. PG/OP communication,<br />

O<strong>PC</strong> server and NCM <strong>PC</strong>;<br />

up to 120 connections, runtime<br />

software, software and electronic<br />

manual on CD-ROM, license key<br />

on USB flash drive, Class A, for<br />

CP 1613/CP 1613 A2/CP 1623/<br />

CP 1628<br />

S7-1613 Edition 2008 (V7.1)<br />

for 32 bit Windows XP Professional<br />

SP2/3; Windows 2003<br />

Server R2, SP2; Windows Vista<br />

Business/Ultimate SP1;<br />

Windows 2008 Server;<br />

English/German<br />

6GK1 716-1CB08-1AA0<br />

Single license for 1 installation D 6GK1 716-1CB71-3AA0<br />

Software Update Service<br />

for 1 year, with automatic<br />

extension; requirement: Current<br />

software version<br />

Upgrade<br />

D 6GK1 716-1CB00-3AL0<br />

from Edition 2006 or higher to<br />

S7-1613 Edition 2008 or V8.1<br />

D 6GK1 716-1CB00-3AE0<br />

from V6.0, V6.1, V6.2 or V6.3 to D 6GK1 716-1CB00-3AE1<br />

S7-1613 Edition 2008 or V8.1<br />

IE TP Cord RJ45/RJ45<br />

TP cable 4 x 2 with<br />

2 RJ45 connectors<br />

0.5 m 6XV1 870-3QE50<br />

1 m 6XV1 870-3QH10<br />

2 m 6XV1 870-3QH20<br />

6 m 6XV1 870-3QH60<br />

10 m 6XV1 870-3QN10<br />

D: Subject to export regulations: AL: N and ECCN: 5D992


■ Overview<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<strong>PC</strong>I Express Card (<strong>PC</strong>Ie x1) with an internal microprocessor<br />

for connection of PG/<strong>PC</strong> to Industrial Ethernet<br />

10/100/1000 Mbit/s (Autosensing/Autocrossover/<br />

Autonegotiation)<br />

Integrated 2-port switch (2 x RJ45 connection)<br />

Communications services via<br />

- Open IE communication (TCP/IP and UDP)<br />

- ISO transport protocol<br />

- PG/OP communication<br />

- S7 communication<br />

- Open communication (SEND/RECEIVE)<br />

Time synchronization<br />

ISO and TCP/IP transport protocol on board<br />

SNMP-supported diagnostics<br />

The appropriate O<strong>PC</strong> server and configuration tools are<br />

included in the scope of supply of the respective<br />

communication software.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<br />

<br />

<strong>PC</strong>-based Automation<br />

Communication — Industrial Ethernet<br />

■ Ordering data Order No.<br />

CP 1623 communication<br />

processor<br />

<strong>PC</strong>I Express x1 card for<br />

connection to Industrial Ethernet<br />

(10/100/1000 Mbit/s) with 2 port<br />

switch (RJ45) connection via<br />

HARDNET-IE S7/S7-1613 and<br />

S7-REDCONNECT, operating<br />

system support see SIMATIC NET<br />

Software<br />

6GK1 162-3AA00<br />

HARDNET-IE S7<br />

for Industrial Ethernet<br />

Software for S7 and open communication,<br />

incl. PG/OP communication,<br />

O<strong>PC</strong> server and NCM <strong>PC</strong>;<br />

up to 120 connections, runtime<br />

software, software and electronic<br />

manual on CD-ROM, license key<br />

on USB flash drive, Class A, for<br />

CP 1613/CP 1613 A2/CP 1623/<br />

CP 1628<br />

S7-1613 Edition 2008 (V7.1)<br />

for 32 bit Windows XP Professional<br />

SP2/3; Windows 2003<br />

Server R2, SP2; Windows Vista<br />

Business/Ultimate SP1;<br />

Windows 2008 Server;<br />

English/German<br />

6GK1 716-1CB08-1AA0<br />

Single license for 1 installation D 6GK1 716-1CB71-3AA0<br />

Software Update Service<br />

for 1 year, with automatic<br />

extension; Prerequisition: Current<br />

software version<br />

Upgrade<br />

D 6GK1 716-1CB00-3AL0<br />

from Edition 2006 or higher to<br />

S7-1613 Edition 2008 or V8.1<br />

D 6GK1 716-1CB00-3AE0<br />

from V6.0, V6.1, V6.2 or V6.3 to D<br />

S7-1613 Edition 2008 or V8.1<br />

IE TP Cord RJ45/RJ45<br />

TP cable 4 x 2 with<br />

2 RJ45 connectors<br />

6GK1 716-1CB00-3AE1<br />

0.5 m 6XV1 870-3QE50<br />

1 m 6XV1 870-3QH10<br />

2 m 6XV1 870-3QH20<br />

6 m 6XV1 870-3QH60<br />

10 m 6XV1 870-3QN10<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

CP 1623<br />

5/309<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Communication — Industrial Ethernet<br />

CP 1628<br />

■ Overview<br />

<br />

<strong>PC</strong>I Express Card (<strong>PC</strong>Ie x1) with an internal microprocessor<br />

for connection of PG/<strong>PC</strong> to Industrial Ethernet<br />

10/100/1000 Mbit/s (Autosensing/Autocrossover/<br />

Autonegotiation)<br />

Integrated 2-port switch (2 x RJ45 connection)<br />

Integrated security mechanisms (e.g. Firewall, VPN)<br />

Communication services via<br />

- Open IE communication (TCP/IP and UDP)<br />

- ISO transport protocol<br />

- PG/OP communication<br />

- S7 communication<br />

- Open communication (SEND/RECEIVE)<br />

Time synchronization<br />

ISO and TCP/IP transport protocol on board<br />

Integration into network management systems through the<br />

support of SNMP (V1/V3)<br />

The appropriate O<strong>PC</strong> servers and configuration tools are<br />

included in the scope of supply of the respective<br />

communication software<br />

5/310<br />

<br />

<br />

<br />

<br />

<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

<br />

<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<br />

<br />

■ Ordering data Order No.<br />

CP 1628 communication<br />

processor<br />

<strong>PC</strong>I Express x1 card for<br />

connection to Industrial Ethernet<br />

(10/100/1000 Mbit/s), with 2-port<br />

switch (RJ45) and integrated<br />

security (firewall, VPN) via<br />

S7-1613 and S7-REDCONNECT.<br />

For operating system support,<br />

see SIMATIC NET Software<br />

H 6GK1 162-8AA00<br />

HARDNET-IE S7 for Industrial<br />

Ethernet<br />

Software for S7 and open communication,<br />

incl. PG/OP communication,<br />

O<strong>PC</strong> server and NCM <strong>PC</strong>;<br />

up to 120 connections, runtime<br />

software, software and electronic<br />

manual on CD-ROM, license key<br />

on USB stick, Class A, for<br />

CP 1613/CP 1613 A2/CP 1623/<br />

CP 1628;<br />

S7-1613 Edition 2008<br />

for 32-bit Windows XP Professional<br />

SP2/3; Windows 2003<br />

Server R2, SP2; Windows Vista<br />

Business/Ultimate SP1;<br />

Windows 2008 Server;<br />

English/German<br />

6GK1 716-1CB08-1AA0<br />

Single license for one installation D 6GK1 716-1CB71-3AA0<br />

Software Update Service<br />

for 1 year with automatic<br />

extension;<br />

Prerequisition: Current software<br />

version<br />

Upgrade<br />

D 6GK1 716-1CB00-3AL0<br />

from Edition 2006 or higher, to<br />

S7-1613 Edition 2008 or V8.1<br />

D 6GK1 716-1CB00-3AE0<br />

from V6.0, V6.1, V6.2 or V6.3 to D<br />

S7-1613 Edition 2008 or V8.1<br />

IE TP Cord RJ45/RJ45<br />

TP cable 4 x 2 with<br />

2 RJ45 connectors<br />

6GK1 716-1CB00-3AE1<br />

0.5 m 6XV1 870-3QE50<br />

1 m 6XV1 870-3QH10<br />

2 m 6XV1 870-3QH20<br />

6 m 6XV1 870-3QH60<br />

10 m 6XV1 870-3QN10<br />

SNMP O<strong>PC</strong> server<br />

including MIP compiler, single<br />

license for 1 installation of runtime<br />

software; software and electronic<br />

manual on CD-ROM; licence key<br />

on USB stick, class A<br />

see page 5/321<br />

SNMP O<strong>PC</strong> server Power Pack<br />

For expansion of<br />

SNMP O<strong>PC</strong> server Basic on<br />

SNMP O<strong>PC</strong> server Extended<br />

see page 5/321<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

H: Subject to export regulations: AL: 9I999 and ECCN: EAR99H


■ Overview<br />

System configuration S7-REDCONNECT<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<br />

<br />

<br />

<strong>PC</strong>-based Automation<br />

Communication — Industrial Ethernet<br />

HARDNET IE S7-REDCONNECT<br />

For connecting <strong>PC</strong>s over redundant Industrial Ethernet to the<br />

SIMATIC S7-400H<br />

Protected from communication failures arising from a fault in<br />

the double bus or in redundant rings<br />

For redundantly configured Industrial Ethernet<br />

Can also be implemented in non-redundant networks<br />

No additional programming overhead for the <strong>PC</strong> and in<br />

H systems<br />

The appropriate O<strong>PC</strong> server and configuration tools are<br />

included in the scope of supply of the respective<br />

communication software<br />

Enhanced redundancy over 4-way communication<br />

(<strong>ST</strong>EP 7 V5.1 + SP4 and higher)<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/311<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Communication — Industrial Ethernet<br />

HARDNET IE S7-REDCONNECT<br />

■ Ordering data Order No. Order No.<br />

S7-REDCONNECT<br />

Power Pack S7-REDCONNECT<br />

Software for fail-safe S7 commu-<br />

For expansion from<br />

nication via redundant networks,<br />

HARDNET IE S7 to<br />

incl. S7 O<strong>PC</strong> server,<br />

S7-REDCONNECT, single license<br />

HARDNET-IE S7, runtime<br />

for 1 installation, runtime software,<br />

software, software and electronic<br />

software and electronic manual<br />

manual on CD-ROM, license key<br />

on CD-ROM, license key on USB<br />

on USB flash drive, Class A;<br />

flash drive, Class A;<br />

S7-REDCONNECT V8.1<br />

HARDNET-IE S7-REDCONNECT 6GK1 716-0HB08-1AC0<br />

for 32/64 bit:<br />

Power Pack V8.1<br />

Windows 7 Professional/Ultimate;<br />

for 32/64 bit:<br />

for 64 bit:<br />

Windows 7 Professional/Ultimate;<br />

Windows 2008 Server R2<br />

for 64 bit:<br />

English/German<br />

Windows 2008 Server R2;<br />

Single license for 1 installation D 6GK1 716-0HB08-1AA0<br />

English/German;<br />

S7-REDCONNECT Edition 2008<br />

(V7.1)<br />

Power Pack S7-REDCONNECT<br />

Edition 2008 (V7.1)<br />

D 6GK1 716-0HB71-3AC0<br />

for 32 bit Windows XP Professional<br />

SP 2/3; Windows 2003<br />

Server R2, SP2; Windows Vista<br />

Business/Ultimate SP1;<br />

Windows 2008 Server;<br />

English/German<br />

for 32 bit Windows XP Professional<br />

SP 2/3; Windows 2003<br />

Server R2, SP2; Windows Vista<br />

Business/Ultimate SP1;<br />

Windows 2008 Server;<br />

English/German<br />

Single license for 1 installation D 6GK1 716-0HB71-3AA0<br />

CP 1613 A2 communication 6GK1 161-3AA01<br />

Software Update Service D 6GK1 716-0HB00-3AL0<br />

processor<br />

Software Update Service for<br />

CP 1623 communication<br />

6GK1 162-3AA00<br />

1 year,<br />

processor<br />

with automatic extension;<br />

requirement: Current software<br />

version<br />

Upgrade<br />

CP 1628 communication<br />

processor<br />

H 6GK1 162-8AA00<br />

from Edition 2006 to<br />

S7-REDCONNECT Edition 2008<br />

or V8.1<br />

D 6GK1 716-0HB00-3AE0<br />

from V6.0, V6.1, V6.2 or V6.3 to D<br />

S7-REDCONNECT Edition 2008<br />

or V8.1<br />

6GK1 716-0HB00-3AE1<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

H: Subject to export regulations: AL: 9I999 and ECCN: EAR99H<br />

5/312<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Overview<br />

<br />

<br />

<br />

S7-1200 <br />

CSM 1277<br />

System configuration SOFTNET for Industrial Ethernet<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<br />

<br />

<br />

<strong>PC</strong>-based Automation<br />

Communication — Industrial Ethernet<br />

SOFTNET for Industrial Ethernet<br />

For coupling PG/<strong>PC</strong>s/workstations to automation systems<br />

Communication services:<br />

- PG/OP communication<br />

- S7 communication<br />

- Open communication (SEND/RECEIVE)<br />

Can be used with<br />

- Layer 2 Ethernet card (<strong>PC</strong>I/<strong>PC</strong>Ie)<br />

- Integrated Industrial Ethernet interface, e. g. CP 1612 A2<br />

- Modem (Remote Access Service RAS)<br />

Complete protocol stack as a software package<br />

The appropriate O<strong>PC</strong> server and configuration tools are<br />

included in the scope of supply of the respective<br />

communication software<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/313<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Communication — Industrial Ethernet<br />

SOFTNET for Industrial Ethernet<br />

■ Ordering data Order No. Order No.<br />

SOFTNET S7 for Industrial<br />

Ethernet<br />

Software for S7 and open communication,<br />

incl. O<strong>PC</strong> server,<br />

PG/OP communication, and<br />

NCM <strong>PC</strong>, runtime software,<br />

software and electronic manual<br />

on CD-ROM, license key on<br />

USB flash drive, Class A<br />

SOFTNET-IE S7 V8.1<br />

for 32/64 bit:<br />

Windows 7 Professional/Ultimate;<br />

for 64 bit:<br />

Windows 2008 server R2;<br />

English/German<br />

up to 64 connections<br />

Single license for 1 installation<br />

SOFTNET-S7 Edition 2008<br />

(V7.1) for Industrial Ethernet<br />

for 32 bit Windows XP Professional<br />

SP2/3; Windows 2003<br />

Server R2, SP2; Windows Vista<br />

Business/Ultimate SP1;<br />

Windows 2008 Server;<br />

English/German<br />

up to 64 connections<br />

D 6GK1 704-1CW08-1AA0<br />

Single license for 1 installation D 6GK1 704-1CW71-3AA0<br />

Software Update Service<br />

Software Update Service for<br />

1 year,<br />

with automatic extension;<br />

requirement: Current software<br />

version<br />

Upgrade<br />

D 6GK1 704-1CW00-3AL0<br />

from Edition 2006 or higher to<br />

Edition 2008 or V8.1<br />

D 6GK1 704-1CW00-3AE0<br />

from V6.0, V6.1, V6.2 or V6.3 to D<br />

Edition 2008 or V8.1<br />

SOFTNET-IE S7 Lean Edition<br />

V8.1<br />

up to 8 connections<br />

6GK1 704-1CW00-3AE1<br />

Single license for 1 installation<br />

SOFTNET-S7 Lean Edition 2008<br />

(V7.1) for Industrial Ethernet<br />

up to 8 connections<br />

D 6GK1 704-1LW08-1AA0<br />

Single license for 1 installation D 6GK1 704-1LW71-3AA0<br />

Software Update Service<br />

Software Update Service for<br />

1 year,<br />

with automatic extension;<br />

requirement: Current software<br />

version<br />

Upgrade<br />

D 6GK1 704-1LW00-3AL0<br />

from Edition 2006 or higher to<br />

Edition 2008 or V8.1<br />

D 6GK1 704-1LW00-3AE0<br />

from V6.0, V6.1, V6.2 or V6.3 to D<br />

Edition 2008 or V8.1<br />

6GK1 704-1LW00-3AE1<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

5/314<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SOFTNET-PG for Industrial<br />

Ethernet<br />

Software for PG/OP communication,<br />

runtime software, software<br />

and electronic manual on<br />

CD-ROM, license key on USB<br />

flash drive, Class A<br />

SOFTNET-IE PG V8.1<br />

for 32/64 bit:<br />

Windows 7 Professional/Ultimate;<br />

for 64 bit:<br />

Windows 2008 Server R2;<br />

English/GermanEnglish/German<br />

Single license for 1 installation<br />

SOFTNET-PG Edition 2008<br />

(V7.1) for Industrial Ethernet<br />

for 32 bit Windows XP Professional<br />

SP2/3; Windows 2003<br />

Server R2, SP2; Windows Vista<br />

Business/Ultimate SP1;<br />

Windows 2008 Server;<br />

English/German<br />

D 6GK1 704-1PW08-1AA0<br />

Single license for 1 installation D 6GK1 704-1PW71-3AA0<br />

Software Update<br />

Software Update Service for<br />

1 year,<br />

with automatic extension;<br />

requirement: Current software<br />

version<br />

Upgrade<br />

D 6GK1 704-1PW00-3AL0<br />

from Edition 2006 or higher to<br />

Edition 2008 or V8.1<br />

D 6GK1 704-1PW00-3AE0<br />

from V6.0, V6.1, V6.2 or V6.3 to D<br />

Edition 2008 or V8.1<br />

IE S7 O<strong>PC</strong> Redundancy<br />

Software for redundant<br />

O<strong>PC</strong> servers in the environment of<br />

Industrial Ethernet software,<br />

S7 products, Runtime software,<br />

software and electronic manual<br />

on CD-ROM, license key on<br />

USB stick, Class A<br />

IE S7 O<strong>PC</strong> Redundancy V8.1<br />

for 64 bit:<br />

Windows 2008 Server R2;<br />

English/German<br />

6GK1 704-1PW00-3AE1<br />

Single license for 1 installation D 6GK17 06-1CW08-1AA0<br />

Software Update Service for<br />

1 year, with automatic extension;<br />

Prerequisition: current software<br />

version<br />

6GK17 06-1CW00-3AL0


■ Overview<br />

<strong>PC</strong> with SOFTNET PN IO as PROFINET IO Controller<br />

<br />

<strong>PC</strong>/I<strong>PC</strong> with<br />

SOFTNET PN IO<br />

<br />

<br />

<br />

<br />

<br />

z.B. S7-300 with<br />

CP 342-5 as Slave<br />

<br />

<br />

<br />

<br />

<br />

SIMATIC NET<br />

O<strong>PC</strong>-Scout<br />

PROFINET<br />

Communication<br />

ET 200S<br />

<br />

PN IO O<strong>PC</strong>-Server<br />

<br />

<br />

Software with PROFINET IO Controller function for coupling<br />

PG/<strong>PC</strong> and I<strong>PC</strong> with PROFINET IO Devices<br />

Possible applications:<br />

- <strong>PC</strong>-based control systems<br />

- HMI systems<br />

- Test applications<br />

Communication services:<br />

- PROFINET IO Controller<br />

Can be used with<br />

- Integrated interfaces of SIMATIC PG/<strong>PC</strong><br />

- You can find more information about the environment of use<br />

at www.siemens.com/simatic-net/ik-info<br />

Cost-effective solution for the low-end performance range<br />

O<strong>PC</strong> server for I/O interfacing over PROFINET included in<br />

scope of supply<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

O<strong>PC</strong> UA<br />

<br />

WinCC<br />

O<strong>PC</strong>-Client<br />

<br />

O<strong>PC</strong> XML DA<br />

as Webservice<br />

<strong>PC</strong>-based Automation<br />

Communication — Industrial Ethernet<br />

COM/DCOM<br />

SOFTNET PN IO<br />

Microsoft Office<br />

O<strong>PC</strong>-Client<br />

<br />

<br />

<br />

<br />

<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SOFTNET PN IO<br />

O<strong>PC</strong> XML<br />

Webclient<br />

Internet<br />

Intranet<br />

G_IK10_XX_10073<br />

5/315<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Communication — Industrial Ethernet<br />

SOFTNET PN IO<br />

■ Ordering data Order No. Order No.<br />

SOFTNET PN IO<br />

SOFTNET PN IO Edition 2008<br />

Software for PROFINET IO<br />

(V7.1)<br />

Controller with O<strong>PC</strong> server and<br />

for 32 bit Windows XP Profes-<br />

NCM <strong>PC</strong>, runtime software,<br />

sional SP 2/3; Windows 2003<br />

software and electronic manual<br />

Server R2, SP2; Windows Vista<br />

on CD-ROM, license key on<br />

Business/Ultimate SP1;<br />

USB flash drive, Class A,<br />

Windows 2008 Server;<br />

SOFTNET-IE PN IO V8.1<br />

English/German<br />

Single license for one installationD 6GK1 704-1HW71-3AA0<br />

for 32/64 bit:<br />

Windows 7 Professional/Ultimate<br />

for 64 bit:<br />

Windows 2008 Server R2<br />

English/German<br />

Single License for one installation<br />

D 6GK1 704-1HW08-1AA0<br />

Software Update Service<br />

Software Update Service for<br />

1 year,<br />

with automatic extension;<br />

requirement: Current software<br />

version<br />

Upgrade<br />

D 6GK1 704-1HW00-3AL0<br />

from Edition 2006 or higher to<br />

SOFTNET PN IO Edition 2008 or<br />

V8.1<br />

D 6GK1 704-1HW00-3AE0<br />

from V6.0, V6.1, V6.2 or V6.3 to D<br />

SOFTNET PN IO Edition 2008 or<br />

V8.1<br />

6GK1 704-1HW00-3AE1<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

5/316<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Overview<br />

<strong>PC</strong>/Windows <strong>PC</strong><br />

DP O<strong>PC</strong> server<br />

FMS O<strong>PC</strong> server<br />

DP protocol<br />

FMS protocol<br />

SIMATIC NET<br />

O<strong>PC</strong>-Scout<br />

PROFIBUS<br />

S7-300<br />

SIMATIC S5<br />

System integration with O<strong>PC</strong> server<br />

O<strong>PC</strong> UA<br />

S7 O<strong>PC</strong> server<br />

S7 communication<br />

WinCC<br />

O<strong>PC</strong>-Client<br />

COM/DCOM<br />

S5 O<strong>PC</strong> server<br />

Open<br />

communication<br />

(SEND/RECEIVE)<br />

O<strong>PC</strong> (Openness, Productivity & Collaboration) is a<br />

standardized, open, and vendor-independent interface that is<br />

widely used in automation.<br />

O<strong>PC</strong> UA (Unified Architecture) is the result of consistent further<br />

development of this standard, offering both interfaces for<br />

SIMATIC S7 and PROFINET.<br />

The appropriate O<strong>PC</strong> servers are included in the scope of<br />

supply of the respective communication software<br />

Standardized, open multi-vendor interface<br />

<strong>PC</strong><br />

ET 200pro<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

PN IO O<strong>PC</strong> server<br />

PROFINET<br />

PROFINET<br />

Industrial Ethernet<br />

<strong>PC</strong>-based Automation<br />

Communication — Industrial Ethernet<br />

Microsoft Office<br />

O<strong>PC</strong>-Client<br />

SNMP<br />

O<strong>PC</strong> server<br />

SNMP<br />

O<strong>PC</strong> server for Industrial Ethernet<br />

<strong>PC</strong><br />

S7-400<br />

O<strong>PC</strong> XML<br />

Webclient<br />

Internet<br />

Intranet<br />

O<strong>PC</strong> XML DA<br />

as Web service<br />

SIMATIC S5<br />

(SEND/RECEIVE only)<br />

It permits interfacing of O<strong>PC</strong>-capable Windows applications<br />

to S7-communication, open communication<br />

(SEND/RECEIVE), PROFINET and SNMP.<br />

Increased availabilty due to additional option packages as<br />

O<strong>PC</strong> server redundancy<br />

O<strong>PC</strong> Scout with browser functionality as an O<strong>PC</strong> client and<br />

OCX Data Control/.NET Data Control for simple O<strong>PC</strong> client<br />

creation<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

G_IK10_XX 10103<br />

5/317<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Communication — Industrial Ethernet<br />

O<strong>PC</strong> server for Industrial Ethernet<br />

■ Ordering data Order No. Order No.<br />

PN CBA O<strong>PC</strong> Server Edition<br />

2008<br />

PROFINET O<strong>PC</strong> server for CBA;<br />

runtime software, software and<br />

electronic manual on CD-ROM,<br />

license key on USB flash drive,<br />

Class A, for 32-bit Windows XP<br />

Professional SP 2/3; Windows<br />

2003 Server R2, SP2;<br />

German/English<br />

Single license for 1 installation D 6GK1 706-0HB71-3AA0<br />

Software Update Service for<br />

1 year,<br />

with automatic extension;<br />

requirement: current software<br />

version<br />

D 6GK1 706-0HB00-3AL0<br />

from Edition 2006 or higher to<br />

Edition 2008, single license<br />

D 6GK1 706-0HB00-3AE0<br />

from V6.0 to Edition 2008,<br />

single license<br />

SNMP O<strong>PC</strong> server<br />

Including MIB compiler; single<br />

license for 1 installation of runtime<br />

software; software and electronic<br />

manual on CD-ROM; license key<br />

on USB flash drive, Class A;<br />

SNMP O<strong>PC</strong> server Basic<br />

Administration of up to<br />

20 IP addresses<br />

D 6GK1 706-0HB00-3AE1<br />

Basic V8.1<br />

for 32/64 bit:<br />

Windows 7 Professional/Ultimate;<br />

for 64 bit:<br />

Windows 2008 Server R2, SP2<br />

Windows Vista Business/<br />

Ultimate SP1;<br />

Windows 2008 Server;<br />

Single License for 1 installation<br />

D 6GK1 706-1NW08-1AA0<br />

Basic 2008 (V7.1)<br />

for 32 bit Windows XP<br />

Professional SP2/3;<br />

Windows 2003 Server R2, SP2;<br />

Windows Vista Business/<br />

Ultimate SP1;<br />

Windows 2008 Server;<br />

Single License for 1 installation<br />

D 6GK1 706-1NW71-3AA0<br />

Software Update Service<br />

SNMP O<strong>PC</strong> server Basic<br />

Software Update Service for<br />

1 year, with automatic extension;<br />

requirement: current software<br />

version<br />

Upgrade SNMP O<strong>PC</strong> server<br />

Basic<br />

from Edition 2006 or higher to<br />

Edition 2008 or V8.1<br />

from V6.0, V6.1, V6.2 or V6.3 to<br />

V8.1<br />

5/318<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

D 6GK1 706-1NW00-3AL0<br />

D 6GK1 706-1NW00-3AE0<br />

D 6GK1 706-1NW00-3AE1<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SNMP O<strong>PC</strong> server Extended<br />

Administration of up to<br />

200 IP addresses<br />

Extended V8.1<br />

for 32/64 bit:<br />

Windows 7 Professional/<br />

Ultimate;<br />

for 64 bit:<br />

Windows 2008 Server R2,<br />

Single License for 1 installation<br />

Extended 2008 (V7.1)<br />

for 32 bit Windows XP<br />

Professional SP2/3;<br />

Windows 2003 Server R2, SP2;<br />

Windows Vista Business/<br />

Ultimate SP1;<br />

Windows 2008 Server;<br />

Single License for 1 installation<br />

D 6GK1 706-1NX08-1AA0<br />

D 6GK1 706-1NX71-3AA0<br />

Software Update Service<br />

SNMP O<strong>PC</strong> server Extended<br />

Software Update Service for<br />

1 year, with automatic extension;<br />

requirement: current software<br />

version<br />

Upgrade SNMP O<strong>PC</strong> server<br />

Extended<br />

D 6GK1 706-1NX00-3AL0<br />

from Edition 2006 or higher to<br />

Edition 2008 or V8.1<br />

D 6GK1 706-1NX00-3AE0<br />

from V6.0, V6.1, V6.2 or V6.3 to D<br />

V8.1<br />

SNMP O<strong>PC</strong> server Power Pack<br />

For upgrade from SNM O<strong>PC</strong><br />

Server Basic to SNM O<strong>PC</strong> Server<br />

Extended<br />

6GK1 706-1NX00-3AE1<br />

Power Pack V8.1 6GK1 706-1NX08-1AC0<br />

Power Pack Edition 2008 (V7.1) D<br />

S7 O<strong>PC</strong> Redundancy<br />

Software for redundant<br />

O<strong>PC</strong> servers in the environment of<br />

Industrial Ethernet software,<br />

S7 products, Runtime software,<br />

software and electronic manual<br />

on CD-ROM, license key on<br />

USB stick, Class A<br />

S7 O<strong>PC</strong> Redundancy V8.1<br />

for Industrial Ethernet<br />

for 64 bit:<br />

Windows 2008 Server R2;<br />

English/German<br />

6GK1 706-1NX71-3AC0<br />

Single License<br />

for 1 installation<br />

D 6GK1 706-1CW08-1AA0<br />

Software Update Service<br />

for 1 year, with automatic<br />

extension; prerequisition: current<br />

software version<br />

6GK1 706-1CW00-3AL0


■ Overview<br />

O<strong>PC</strong> (Openness, Productivity & Collaboration) is a<br />

standardized, open, and vendor-independent interface that is<br />

widely used in automation. O<strong>PC</strong> UA (Unified Architecture) is the<br />

result of consistent further development of this standard, offering<br />

additional functions such as security or redundancy.<br />

S7 O<strong>PC</strong> Redundancy is a software product compliant with the<br />

O<strong>PC</strong> UA standard that enables the redundant configuration of<br />

O<strong>PC</strong> UA servers to SIMATIC S7. The availability of automation<br />

data to operator control and monitoring systems is guaranteed<br />

thanks to the redundant use of O<strong>PC</strong> UA servers. This requires<br />

neither additional cabling for synchronizing the redundant<br />

O<strong>PC</strong> UA servers, nor additional programming overhead in the<br />

<strong>PC</strong>. The O<strong>PC</strong> UA servers are synchronized via high-performance<br />

Industrial Ethernet network access points at 10/100 and<br />

1000 bit/s. S7 O<strong>PC</strong> Redundancy represents an integrated<br />

customer solution for all SIMATIC NET S7 SOFTNET and<br />

HARDNET software products in the automation world.<br />

■ Design<br />

S7 O<strong>PC</strong> redundancy<br />

Station A<br />

Industrial Ethernet<br />

Redundant use of O<strong>PC</strong> servers<br />

O<strong>PC</strong> UA<br />

synchronization<br />

Industrial Ethernet<br />

PROFIBUS<br />

HMI<br />

S7 O<strong>PC</strong> redundancy<br />

Station B<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_IK10_XX_10295<br />

<strong>PC</strong>-based Automation<br />

Communication — Industrial Ethernet<br />

S7 O<strong>PC</strong> Redundancy for Industrial Ethernet<br />

■ Ordering data Order No.<br />

S7 O<strong>PC</strong> Redundancy<br />

Software for redundant<br />

O<strong>PC</strong> servers in the environment of<br />

Industrial Ethernet software,<br />

S7 products, Runtime software,<br />

software and electronic manual<br />

on CD-ROM, license key on<br />

USB stick, Class A<br />

S7 O<strong>PC</strong> Redundancy V8.1 for<br />

Industrial Ethernet<br />

for 64 bit: Windows 2008 Server<br />

R2; English/German<br />

Single license for one installationD 6GK1 706-1CW08-1AA0<br />

Software Update Service 6GK1 706-1CW00-3AL0<br />

for 1 year with automatic<br />

extension;<br />

Prerequisition: Current software<br />

version<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/319<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Communication — Industrial Ethernet<br />

SNMP O<strong>PC</strong> server<br />

■ Overview<br />

5/320<br />

Pump Main<br />

Pump Substation 1<br />

Pumpstation Network<br />

1GBit<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Pump Old<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

S_IK10_XX_00004<br />

Status monitoring of SNMP-capable devices in any O<strong>PC</strong> client<br />

systems; e. g. SIMATIC WinCC/<strong>PC</strong>S 7<br />

Easy access to SNMP-capable devices over the<br />

O<strong>PC</strong> interface<br />

Devices without SNMP agents can be monitored using the<br />

ping mechanism<br />

Configuration with <strong>ST</strong>EP 7 or NCM <strong>PC</strong><br />

SNMP diagnostics profiles for <strong>Siemens</strong> devices,<br />

e.g. SCALANCE X/W<br />

Generation of optional SNMP diagnostics profiles with the<br />

integrated MIB compiler<br />

Easy design of monitoring devices with the aid of the<br />

autodiscovery function


<strong>PC</strong>-based Automation<br />

Communication — Industrial Ethernet<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SNMP O<strong>PC</strong> server<br />

■ Ordering data Order No. Order No.<br />

SNMP O<strong>PC</strong> server<br />

SNMP O<strong>PC</strong> server Extended<br />

Including MIB compiler; single<br />

Administration of up to<br />

license for 1 installation of runtime<br />

200 IP addresses<br />

software; software and electronic<br />

manual on CD-ROM; license key<br />

on USB flash drive, Class A;<br />

Extended V8.1<br />

for 32/64 bit:<br />

Windows 7 Professional/<br />

D 6GK1 706-1NX08-1AA0<br />

SNMP O<strong>PC</strong> server Basic<br />

Ultimate;<br />

for 64 bit:<br />

Administration of up to<br />

Windows 2008 Server R2,<br />

20 IP addresses<br />

Single License for 1 installation<br />

Basic V8.1<br />

D 6GK1 706-1NW08-1AA0<br />

Extended 2008 (V7.1) D 6GK1 706-1NX71-3AA0<br />

for 32/64 bit:<br />

for 32 bit Windows XP<br />

Windows 7 Professional/<br />

Professional SP2/3;<br />

Ultimate;<br />

Windows 2003 Server R2, SP2;<br />

for 64 bit:<br />

Windows Vista Business/<br />

Windows 2008 Server R2,<br />

Ultimate SP1;<br />

Single License for 1 installation<br />

Windows 2008 Server;<br />

Basic 2008 (V7.1)<br />

D 6GK1 706-1NW71-3AA0<br />

Single License for 1 installation<br />

for 32 bit Windows XP<br />

Professional SP2/3;<br />

Windows 2003 Server R2, SP2;<br />

Software Update Service<br />

SNMP O<strong>PC</strong> server Extended<br />

D 6GK1 706-1NX00-3AL0<br />

Windows Vista Business/<br />

Software Update Service for<br />

Ultimate SP1;<br />

1 year, with automatic extension;<br />

Windows 2008 Server;<br />

Prerequisition: current software<br />

Single License for 1 installation<br />

version<br />

Software Update Service D 6GK1 706-1NW00-3AL0<br />

Upgrade SNMP O<strong>PC</strong> server<br />

SNMP O<strong>PC</strong> server Basic<br />

Extended<br />

Software Update Service for<br />

1 year, with automatic extension;<br />

requirement: current software<br />

version<br />

from Edition 2006 or higher to D<br />

Edition 2008 or V8.1<br />

from V6.0, V6.1, V6.2 or V6.3 to D<br />

V8.1<br />

6GK1 706-1NX00-3AE0<br />

6GK1 706-1NX00-3AE1<br />

Upgrade SNMP O<strong>PC</strong> server<br />

SNMP O<strong>PC</strong> server Power Pack<br />

Basic<br />

from Edition 2006 or higher to<br />

Edition 2008 or V8.1<br />

D 6GK1 706-1NW00-3AE0<br />

For extension of<br />

SNM O<strong>PC</strong> Server Basic to<br />

SNM O<strong>PC</strong> Server Extended<br />

from V6.0, V6.1, V6.2 or V6.3 to D<br />

V8.1<br />

6GK1 706-1NW00-3AE1<br />

Power Pack V8.1 6GK1 706-1NX08-1AC0<br />

Power Pack Edition 2008 (V7.1) D 6GK1 706-1NX71-3AC0<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

5/321<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Communication — Industrial Ethernet<br />

SINEMA E<br />

■ Overview<br />

Engineering tool for support with planning, configuration,<br />

simulation and measurement of an IWLAN radio field on site<br />

(Site Survey) according to the IEEE <strong>80</strong>2.11 a/b/g/h standard<br />

Automatic determination of the WLAN infrastructure for new<br />

and existing networks<br />

Optimization functions for minimization of channel<br />

interference<br />

Visualization and analysis of WLAN networks according to<br />

signal strength, data rate, signal-to-noise ratio, overlapping<br />

and applications (PROFINET, TCP/IP, Voice over WLAN)<br />

Configuration of single and multiple devices as well as<br />

uploading/downloading of IWLAN device parameters<br />

Site survey functions (measurements) for the acquisition,<br />

conditioning, evaluation and visualization of measured<br />

WLAN signals<br />

Integrated and expandable catalog entries for WLAN devices,<br />

antennas and radio hindrances as well as standard graphic<br />

formats for importing layout plans<br />

Report function for documenting the configured and<br />

measured WLAN infrastructure<br />

5/322<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Ordering data<br />

SINEMA E<br />

Engineering software for<br />

planning, configuring, simulating<br />

and measuring (Site Survey)<br />

industrial WLAN applications in<br />

office and industrial environments<br />

on PG/<strong>PC</strong> in accordance<br />

with IEEE <strong>80</strong>2.11 a/b/g/h<br />

standard;<br />

software and electronic manual<br />

on CD-ROM, license key on<br />

diskette, Class A, for 32-bit<br />

Windows XP Professional +SP2;<br />

German/English<br />

Order No.<br />

SINEMA E 2006 Lean<br />

Planning, configuring and<br />

simulating WLAN applications<br />

D 6GK1 781-0AA00-6AA0<br />

SINEMA E 2006 standard<br />

Extended planning, configuring,<br />

simulating and measuring (site<br />

survey) of WLAN applications<br />

(automatic placement, application<br />

profile, contour presentation,<br />

storage/comparison of<br />

simulations, extended filter<br />

options)<br />

D 6GK1 782-0AA00-6AA0<br />

SINEMA E 2006 Power pack<br />

Software upgrade from<br />

SINEMA E Lean to<br />

SINEMA E Standard<br />

D 6GK1 782-4AA00-6AC0<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

■ More information<br />

You can find further information on the Internet at:<br />

www.siemens.com/sinema


■ Overview<br />

SINEMA Server is a web-based network monitoring software that<br />

significantly reduces the response time to communication<br />

problems in industrial networks and thus avoids downtimes and<br />

saves costs.<br />

Also easy to use for plant operators or service personnel for<br />

autonomous detection and elimination of communication<br />

problems<br />

Graphical representation of industrial network structures<br />

Standardized network documentation (reports for SLAs<br />

(Service Level Agreements))<br />

Simple operation via Web browser or an HMI/SCADA<br />

application, without the need for specialized IT knowledge<br />

Automatic saving of network data such as the network<br />

topology and device information<br />

Low installation and maintenance outlay, in particular through<br />

the use of pre-installed industrial <strong>PC</strong>s (Microbox <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>427C)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>PC</strong>-based Automation<br />

Communication — Industrial Ethernet<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SINEMA server<br />

■ Ordering data<br />

SINEMA Server Basic V11<br />

Network monitoring software for<br />

industrial Ethernet and PROFINET<br />

networks, Runtime software,<br />

software and electronic manual<br />

on CD-ROM, license key on<br />

USB stick; Software for installation<br />

on <strong>PC</strong> hardware with 32 bit<br />

Windows XP, Windows 2003<br />

Server R2 and Windows 7;<br />

German/English<br />

Order No.<br />

For 50 via IP address<br />

identifiable devices<br />

D 6GK1 781-1BA01-1AA0<br />

For 100 via IP address<br />

identifiable devices<br />

D 6GK1 781-1DA01-1AA0<br />

For 250 via IP address<br />

identifiable devices<br />

D 6GK1 781-1HA01-1AA0<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

5/323<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Communication — PROFIBUS<br />

Connection options to SIMATIC <strong>PC</strong>s<br />

■ Overview<br />

The operating systems listed in the table refer exclusively to the<br />

communication products specified!<br />

Communication<br />

hardware<br />

Connection options of PROFIBUS CPs to PG/<strong>PC</strong><br />

5/324<br />

Communication<br />

software<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Operating system environment of the<br />

communication software<br />

Windows 7 Professional /<br />

Ultimate<br />

Windows Server 2008 R2<br />

Windows Server 2008 +<br />

SP1/2<br />

Vista Business /<br />

Ultimate + SP1/2<br />

Windows XP Pro + SP3<br />

Windows Server 2003 +<br />

SP1/2<br />

Windows Server 2003 R2 /<br />

SP2<br />

Please refer to the description of the relevant I<strong>PC</strong> for the<br />

operating system that is available and has been released for<br />

that I<strong>PC</strong>.<br />

Embedded Systems<br />

other operating systems<br />

SIMATIC Industrial <strong>PC</strong>/<br />

Field PG<br />

Field PG M3<br />

SIMATIC I<strong>PC</strong>847C<br />

SIMATIC I<strong>PC</strong>647C<br />

SIMATIC I<strong>PC</strong>547C,<br />

SIMATIC HMI I<strong>PC</strong>577D<br />

SIMATIC I<strong>PC</strong>627C<br />

SIMATIC I<strong>PC</strong>827C<br />

SIMATIC I<strong>PC</strong>427C<br />

Op.<br />

sys.<br />

Windows XP Embedded +<br />

SP1/SP2/FP 2007<br />

SIMATIC<br />

Industrial <strong>PC</strong>s 3)<br />

CPs and software for Industrial Ethernet<br />

CP 5603 CP with DP-Base ● ● ● ● ● ● ● - - - - - - - ● ● ● ●<br />

(<strong>PC</strong>I-104) HARDNET-PB DP DK 1)<br />

(DK-5613, DP-base) ○ ○ ○ ○ ○ ○ ○ ○ - - - - - - ○ ○ ○ ○ - - ○5) HARDNET-PB DP<br />

(DP-5613) ● ● ● ● ● ● ● - - - - - - - ● ● ● ●<br />

HARDNET-PB S7<br />

(S7-5613) ● ● ● ● ● ● ● - - - - - - - ● ● ● ●<br />

S7 O<strong>PC</strong> Redundancy for<br />

PROFIBUS - ● - - - - - - - - - - - - ● ● ● ●<br />

CP 5613 A2, CP mit DP-Base ● ● ● ● ● ● ● - - ● ● ● ● ● - - - - ● ● -<br />

CP 5614 A2<br />

(<strong>PC</strong>I 32 Bit)<br />

HARDNET-PB DP DK 1)<br />

(DK-5613, DP-base) ○ ○ ○ ○ ○ ○ ○ ○ - ○ ○ ○ ○ ○ - ○ - - ○<br />

HARDNET-PB DP<br />

(DP-5613) ● ● ● ● ● ● ● - - ● ● ● ● ● - - - - ● ● -<br />

HARDNET-PB S7<br />

(S7-5613) ● ● ● ● ● ● ● - - ● ● ● ● ● - - - - ● ● -<br />

S7 O<strong>PC</strong> Redundancy for<br />

PROFIBUS - ● - - - - - - - ● ● ● ● ● - - - - ● ● -<br />

CP 5623, CP with DP-Base ● ● ● ● ● ● ● - - ●<br />

CP 5624<br />

(<strong>PC</strong>Ie x1)<br />

4) - ● ○4) ● - - - - ○4) ○4) -<br />

HARDNET-PB DP DK 1)<br />

(DK-5613, DP-base) ○ ○ ○ ○ ○ ○ ○ ○ - ○ - ○ ○ ○ - ○ - - ○4) ○4) -<br />

HARDNET-PB DP<br />

(DP-5613) ● ● ● ● ● ● ● - - ●4) - ● ○4) ● - - - - ○4) ○4) -<br />

HARDNET-PB S7<br />

(S7-5613) ● ● ● ● ● ● ● - - ●4) - ● ○4) ● - - - - ○4) ○4) -<br />

S7 O<strong>PC</strong> Redundancy for<br />

PROFIBUS - ● - - - - - - - ●4) - ● ○4) ● - - - - ○4) ○4) -<br />

CP 5611 A2 SOFTNET-PB DP ● ● ● ● ● ● ● - - ● ● ● ● ● - - - - ●<br />

(<strong>PC</strong>I 32 Bit)<br />

SOFTNET-PB DP Slave ● ● ● ● ● ● ● - - ● ● ● ● ● - - - - ●<br />

SOFTNET-PB S7 ● ● ● ● ● ● ● - - ● ● ● ● ● - - - - ●<br />

S7 O<strong>PC</strong> Redundancy for<br />

PROFIBUS - ● - - - - - - - ● ● ● ● ● - - - - ●<br />

CP 5621 SOFTNET-PB DP ● ● ● ● ● ● ● - - ●<br />

(<strong>PC</strong>Ie x1)<br />

4) - ● ○4) ● - - - - ○4) ○4) -<br />

SOFTNET-PB DP Slave ● ● ● ● ● ● ● - - ●4) - ● ○4) ● - - - - ○4) ○4) -<br />

SOFTNET-PB S7 ● ● ● ● ● ● ● - - ●4) - ● ○4) ● - - - - ○4) ○4) -<br />

S7 O<strong>PC</strong> Redundancy for<br />

PROFIBUS - ● - - - - - - - ●4) - ● ○4) ● - - - - ○4) ○4) -<br />

CP 5512 SOFTNET-PB DP - - ● ● ● ● ● - ● - - - - - - - - - - - -<br />

(Cardbus 32 Bit)<br />

SOFTNET-PB DP Slave - - ● ● ● ● ● - ● - - - - - - - - - - - -<br />

SOFTNET-PB S7 - - ● ● ● ● ● - ● - - - - - - - - - - - -<br />

CP 5711 SOFTNET-PB DP ● ● ● ● ● ● ● - ●<br />

(USB V2.0)<br />

SOFTNET-PB DP Slave ● ● ● ● ● ● ● - ●<br />

SOFTNET-PB S7 ● ● ● ● ● ● ● - ●<br />

S7 O<strong>PC</strong> Redundancy for<br />

PROFIBUS - ● - - - - - - ●<br />

SIMATIC PG/<strong>PC</strong> SOFTNET-PB DP ● ● ● ● ● ● ● - ● ○2) ○2) - ○2) ○2) ○2) ● ○2) ● ○2) ○2) -<br />

SOFTNET-PB DP Slave ● ● ● ● ● ● ● - ● ○2) ○2) - ○2) ○2) ○2) ● ○2) ● ○2) ○2) -<br />

SOFTNET-PB S7 ● ● ● ● ● ● ● - ● ○2) ○2) - ○2) ○2) ○2) ● ○2) ● ○2) ○2) -<br />

S7 O<strong>PC</strong> Redundancy for<br />

PROFIBUS - ● - - - - - - ● ○2) ○2) - ○2) ○2) ○2) ● ○2) ● ○2) ○2) suitable •<br />

not suitable -○<br />

-<br />

1) In order to use these CPs in other operating system environments, it is required<br />

to port HARDNET DP Development Kits (DK-5613) into the respective<br />

operating system. You can request the HARDNET DP DK in the Internet under<br />

www.siemens.com/simatic-net/dk5613.<br />

2) integrated PROFIBUS interface is optional<br />

3) depending on available memory and processor performance there could be<br />

restrictions<br />

4) depending on the slots of the selected <strong>PC</strong> version<br />

5) EM-<strong>PC</strong>I 104 expansion module is required<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Notes<br />

- Please always note the supplementary conditions for the specified SIMATIC NET products<br />

that you can view on the Internet pages shown below.<br />

- for further details on XP embedded, see<br />

http://support.automation.siemens.com/WW/view/de/ 21661049<br />

- further details on system requirements and operating environments can be found in the<br />

Readme file of the communication products on the SIMATIC NET <strong>PC</strong> Software CD V8.1<br />

- Updates and supplements to the catalog entries, as well as the above tables can be<br />

viewed at http://www.siemens.com/simatic-net/ik-info<br />

SIMATIC I<strong>PC</strong>427C<br />

SIMATIC HMI I<strong>PC</strong>477C<br />

SIMATIC HMI I<strong>PC</strong>677C<br />

suitable under<br />

certain conditions<br />

SIMATIC I<strong>PC</strong>627C<br />

SIMATIC S7 modular<br />

Embedded Controller


■ Overview<br />

Note:<br />

FMS-5613 supports up to two CP 5603/CP 5613 A2/5614 A2/<br />

CP 5623/CP 5624 processors<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<br />

<strong>PC</strong>-based Automation<br />

Communication — PROFIBUS<br />

■ Ordering data Order No.<br />

CP 5603 communication<br />

processor<br />

<strong>PC</strong>I-104 card for connection to<br />

PROFIBUS incl. DP-Base<br />

software with NCM <strong>PC</strong>; DP-RAM<br />

interface for DP master or<br />

DP slave, incl. PG and FDL<br />

protocols; single license for<br />

1 installation, runtime software,<br />

software and electronic manual<br />

on CD-ROM, Class A, for<br />

operating system support see<br />

SIMATIC NET software;<br />

German/English<br />

A 6GK1 560-3AA00<br />

Software-Upgrade<br />

for CP 5603, CP 5613 A2 and<br />

CP 5623 to Edition 2008 or V8.1<br />

6GK1 561-3AA01-3AE0<br />

CP 5603 Microbox Package<br />

For use of CP 5603 in Microbox<br />

A 6GK1 560-3AU00<br />

<br />

420/427B/427C; consisting of<br />

CP 5603 module and Microbox<br />

expansion frame<br />

CP 5603 expansion rack<br />

for use in Microbox 420/427B with<br />

6GK1 560-3AA00-0AU0<br />

<strong>PC</strong>I-104 interface card with own microprocessor for<br />

mounting material<br />

connecting embedded systems with <strong>PC</strong>I-104 interface to CP 5603 mEC Package A 6GK1 560-3AE00<br />

PROFIBUS at up to 12 Mbit/s<br />

For use of CP 5603 in<br />

Function compatible with CP 5613 A2<br />

SIMATIC S7-MEC;<br />

Communication services:<br />

- PROFIBUS DP master Class 1 and 2 or DP slave according<br />

to IEC 61158/61784<br />

- PG/OP communication with <strong>ST</strong>EP 5 and <strong>ST</strong>EP 7<br />

consisting of CP 5603 and<br />

withdrawable unit for CP 5603 for<br />

installation in the EM <strong>PC</strong>I-104<br />

expansion module of the<br />

SIMATIC S7-MEC<br />

- S7 communication with HARDNET S7 software package<br />

- Open communication (SEND/RECEIVE) based on the<br />

FDL interface<br />

- PROFIBUS FMS according to IEC 61158/61784 with<br />

FMS-5613 software package<br />

CP 5603 insert plate<br />

Metal plate with RS485 cutout for<br />

inserting for the S7 modular<br />

embedded controller<br />

6GK1 560-3AA00-0AE0<br />

Extensive diagnostics options for installation, commissioning<br />

and operation of the module<br />

Event and filter mechanism for reducing the load on the<br />

host CPU<br />

Multiprotocol operation and parallel operation of up to<br />

Development Kit DK-5613<br />

Software development kit<br />

HARDNET-PB DP for CP 5603,<br />

CP 5613, CP 5613 A2, CP 5623,<br />

CP 5613 FO, CP 5614,<br />

CP 5614 A2, CP 5624;<br />

see<br />

www.siemens.com/<br />

simatic-net/dk5613<br />

three CPs<br />

for integration into other operating<br />

The appropriate O<strong>PC</strong> server and configuration tools are<br />

included in the scope of delivery of the respective<br />

system environments on systems<br />

with a <strong>PC</strong>I slot<br />

communication software<br />

Linux-based development kit with driver sources for<br />

integration into "non-Windows" environments<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

CP 5603<br />

5/325<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Communication — PROFIBUS<br />

CP 5603<br />

■ Ordering data Order No. Order No.<br />

HARDNET-PB DP<br />

Software for DP, incl. PG and<br />

FDL protocol, O<strong>PC</strong> server and<br />

NCM <strong>PC</strong>; runtime software,<br />

software and electronic manual<br />

on CD-ROM, license key on<br />

USB flash drive, Class A; for<br />

CP 5603, CP 5613, CP 5613 A2,<br />

CP 5623, CP 5614 A2, CP 5624;<br />

HARDNET-PB DP V8.1<br />

for 32/64 bit:<br />

Windows 7 Professional/Ultimate;<br />

for 32/64 bit:<br />

Windows 2008 Server R2<br />

English/German<br />

Single license for 1 installation<br />

DP-5613 Edition 2008<br />

for 32 bit Windows XP Professional<br />

SP2/3; Windows 2003<br />

Server R2, SP2; Windows Vista<br />

Business/Ultimate SP1;<br />

Windows 2008 Server;<br />

English/German<br />

D 6GK1 713-5DB08-1AA0<br />

Single license for 1 installation D 6GK1 713-5DB71-3AA0<br />

Software Update Service<br />

Software Update Service for<br />

1 year,<br />

with automatic extension;<br />

requirement: current software<br />

version<br />

Upgrade<br />

D 6GK1 713-5DB00-3AL0<br />

from Edition 2006 or 2007 to<br />

DP-5613 Edition 2008 or<br />

HARDNET DP V8.1<br />

D 6GK1 713-5DB00-3AE0<br />

from V6.0, V6.1, V6.2 or V6.3 to D<br />

DP-5613 Edition 2008 or<br />

HARDNET DP V8.1<br />

6GK1 713-5DB00-3AE1<br />

HARDNET-PB S7<br />

Software for S7 communication,<br />

incl. PG and FDL protocol,<br />

O<strong>PC</strong> server and NCM <strong>PC</strong>; runtime<br />

software, software and electronic<br />

manual on USB flash drive,<br />

Class A; for CP 5603,<br />

CP 5613 A2, CP 5623, CP 5614,<br />

CP 5614 A2, CP 5624;<br />

see page 5/312<br />

HARDNET-PB S7 V8.1<br />

for 32/64 bit:<br />

Windows 7 Professional/Ultimate;<br />

for 64 bit:<br />

Windows 2008 Server R2<br />

English/German<br />

Single license for 1 installation<br />

S7-5613 Edition 2008<br />

for 32 bit Windows XP Professional<br />

SP2/3; Windows 2003<br />

Server R2, SP2; Windows Vista<br />

Business/Ultimate SP1;<br />

Windows 2008 Server;<br />

English/German<br />

D 6GK1 713-5CB08-1AA0<br />

Single license for 1 installation D 6GK1 713-5CB71-3AA0<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

■ More information<br />

You can find further information about the HARDNET-PB DP<br />

Development Kit on the Internet at:<br />

www.siemens.com/simatic-net/dk5613<br />

5/326<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Software Update Service<br />

Software Update Service for<br />

1 year, with automatic extension;<br />

requirement: current software<br />

version<br />

Upgrade<br />

D 6GK1 713-5CB00-3AL0<br />

from Edition 2006 or 2007 to<br />

S7-5613 Edition 2008 or<br />

HARDNET S7 V8.1<br />

D 6GK1 713-5CB00-3AE0<br />

from V6.0, V6.1, V6.2 or V6.3 to D<br />

S7-5613 Edition 2008 or<br />

HARDNET S7 V8.1<br />

6GK1 713-5CB00-3AE1<br />

FMS-5613 Edition 2008<br />

Software for FMS protocol incl.<br />

PG/OP communication; FDL,<br />

FMS-O<strong>PC</strong> server and NCM <strong>PC</strong>;<br />

runtime software, software and<br />

electronic manual on USB stick,<br />

Class A, for 32-bit Windows XP<br />

Professional SP2/3; Windows<br />

2003 Server R2, SP2; Windows<br />

Vista Business/Ultimate SP1;<br />

Windows 2008 Server; for<br />

CP 5603, CP 5613, CP 5613 A2,<br />

CP 5623, CP 5613 FO, CP 5614,<br />

CP 5614 A2, CP 5624;<br />

German/English<br />

Single license for 1 installation D 6GK1 713-5FB71-3AA0<br />

Software Update Service<br />

Software Update Service for<br />

1 year, with automatic extension;<br />

requirement: current software<br />

version<br />

Upgrade<br />

D 6GK1 713-5FB00-3AL0<br />

from Edition 2006 or 2007 to<br />

FMS-5613 Edition 2008<br />

D 6GK1 713-5FB00-3AE0<br />

from V6.0, V6.1, V6.2 or V6.3 to D<br />

FMS-5613 Edition 2008<br />

6GK1 713-5FB00-3AE1<br />

PROFIBUS FC Standard<br />

Cable GP<br />

Standard type with special design<br />

for quick assembly, 2-core,<br />

shielded,<br />

sold in meters;<br />

delivery unit max. 1000 m,<br />

minimum order 20 m<br />

6XV1 830-0EH10<br />

PROFIBUS FastConnect bus<br />

connector<br />

RS485 Plug 1<strong>80</strong><br />

With 1<strong>80</strong>° cable outlet, insulation<br />

displacement<br />

6GK1 500-0FC10<br />

PROFIBUS bus terminal 12M<br />

Bus terminal for connection of<br />

PROFIBUS stations up to<br />

12 Mbit/s with plug-in cable<br />

1.5 m long<br />

6GK1 500-0AA10<br />

PROFIBUS FastConnect<br />

Stripping Tool<br />

Preset stripping tool for fast<br />

stripping of PROFIBUS<br />

FastConnect bus cables<br />

6GK1 905-6AA00


■ Overview<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<br />

<strong>PC</strong>-based Automation<br />

Communication — PROFIBUS<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

CP 5613 A2<br />

■ Ordering data Order No.<br />

CP 5613 A2 communication<br />

processor<br />

<strong>PC</strong>I card (32-bit; 3.3 V/5 V) for<br />

connection to PROFIBUS<br />

including DP-Base software with<br />

NCM <strong>PC</strong>; DP-RAM interface for<br />

DP master, including PG and FDL<br />

protocol; single license for<br />

1 installation, runtime software,<br />

software and electronic manual<br />

on CD-ROM, Class A, operating<br />

system support see SIMATIC NET<br />

software;<br />

German/English<br />

6GK1 561-3AA01<br />

Software Upgrade<br />

for CP 5603, CP 5613 A2 and<br />

CP 5623 on Edition 2008 or V8.1<br />

6GK1 561-3AA01-3AE0<br />

<br />

HARDNET-PB DP Development<br />

Kit<br />

Software HARDNET-PB DP Development<br />

Kit for CP 5613/CP 5614/<br />

CP 5613 A2/CP 5614 A2/<br />

CP 5613 FO for integration in<br />

other operating system environments<br />

on systems with a <strong>PC</strong>I slot<br />

see<br />

www.siemens.com/<br />

simatic-net/dk5613<br />

<strong>PC</strong>I card (universal keyed 5 V/3.3 V) with own microprocessor HARDNET-PB DP<br />

for connection of <strong>PC</strong>s and SIMATIC PG/<strong>PC</strong> to PROFIBUS at up<br />

to 12 Mbit/s<br />

Software for DP, incl. PG and FDL<br />

protocol, O<strong>PC</strong> server and<br />

Communication services:<br />

- PROFIBUS DP master according to IEC 61158/61784 on a<br />

<strong>PC</strong>I card<br />

- PG/OP communication with <strong>ST</strong>EP 5 and <strong>ST</strong>EP 7<br />

- S7 communication with HARDNET S7 software package<br />

- Open communication (SEND/RECEIVE) based on the<br />

FDL interface<br />

NCM <strong>PC</strong>; runtime software,<br />

software and electronic manual<br />

on CD-ROM, license key on<br />

USB flash drive, Class A; for<br />

CP 5603, CP 5613 A2, CP 5623,<br />

CP 5614 A2, CP 5624;<br />

HARDNET-PB DP V8.1<br />

- PROFIBUS FMS according to IEC 61158/61784 with<br />

for 32/64 bit:<br />

FMS-5613 software package<br />

Comprehensive diagnostic possibilities for installation,<br />

commissioning and operation of the module<br />

Windows 7 Professional/Ultimate;<br />

for 64 bit:<br />

Windows 2008 Server R2<br />

English/German<br />

High performance over direct dual-port RAM access<br />

Single license for 1 installation D 6GK1 713-5DB08-1AA0<br />

Event and filter mechanisms to reduce the loading on the DP-5613 Edition 2008<br />

host CPU<br />

for 32 bit Windows XP Profes-<br />

Multiprotocol operation and parallel operation of up to<br />

sional SP2/3; Windows 2003<br />

four CPs<br />

Implementation in Motion Control applications is possible<br />

because a constant bus cycle time is supported<br />

Server R2, SP2; Windows Vista<br />

Business/Ultimate SP1;<br />

Windows 2008 Server;<br />

English/German<br />

The appropriate O<strong>PC</strong> servers and configuration tools are Single license for 1 installation D 6GK1 713-5DB71-3AA0<br />

included in the scope of supply of the respective<br />

communications software<br />

Software Update Service<br />

Software Update Service for<br />

1 year, with automatic extension;<br />

requirement: current software<br />

version<br />

Upgrade<br />

D 6GK1 713-5DB00-3AL0<br />

from Edition 2006 or 2007 to<br />

DP-5613 Edition 2008 or<br />

HARDNET DP V8.1<br />

D 6GK1 713-5DB00-3AE0<br />

from V6.0, V6.1, V6.2 or V6.3 to D<br />

DP-5613 Edition 2008 or<br />

HARDNET DP V8.1<br />

6GK1 713-5DB00-3AE1<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

5/327<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Communication — PROFIBUS<br />

CP 5613 A2<br />

■ Ordering data Order No. Order No.<br />

HARDNET-PB S7<br />

Software for S7 communication,<br />

incl. PG and FDL protocol,<br />

O<strong>PC</strong> server and NCM <strong>PC</strong>; runtime<br />

software, software and electronic<br />

manual on USB flash drive,<br />

Class A; for CP 5603,<br />

CP 5613 A2, CP 5623,<br />

CP 5614 A2, CP 5624;<br />

HARDNET-PB S7 V8.1<br />

for 32/64 bit:<br />

Windows 7 Professional/Ultimate;<br />

for 64 bit:<br />

Windows 2008 Server R2<br />

English/German<br />

Single license for 1 installation<br />

S7-5613 Edition 2008<br />

for 32 bit Windows XP Professional<br />

SP2/3; Windows 2003<br />

Server R2, SP2; Windows Vista<br />

Business/Ultimate SP1;<br />

Windows 2008 Server;<br />

English/German<br />

D 6GK1 713-5CB08-1AA0<br />

Single license for 1 installation D 6GK1 713-5CB71-3AA0<br />

Software Update Service<br />

Software Update Service for<br />

1 year, with automatic extension;<br />

requirement: current software<br />

version<br />

Upgrade<br />

D 6GK1 713-5CB00-3AL0<br />

from Edition 2006 or 2007 to<br />

S7-5613 Edition 2008 or<br />

HARDNET S7 V8.1<br />

D 6GK1 713-5CB00-3AE0<br />

from V6.0, V6.1, V6.2 or V6.3 to D<br />

S7-5613 Edition 2008 or<br />

HARDNET S7 V8.1<br />

6GK1 713-5CB00-3AE1<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

■ More information<br />

You can find the HARDNET-PB DP Development Kit on the<br />

Internet.<br />

www.siemens.com/simatic-net/dk5613<br />

The CP 5613 A2 module can also be used under the LINUX and<br />

UNIX operating systems. You can find information about the<br />

available LINUX distributors and UNIX operating systems from:<br />

5/328<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

FMS-5613 Edition 2008<br />

Software for FMS protocol,<br />

including PG/OP communication,<br />

FDL, FMS-O<strong>PC</strong> server and NCM<br />

<strong>PC</strong>; runtime software, software<br />

and electronic manual on USB<br />

flash drive, Class A for 32-bit<br />

Windows XP Professional SP2/3,<br />

Windows 2003 Server R2, SP2,<br />

Windows Vista Business/Ultimate<br />

SP1; Windows 2008 Server; for<br />

CP 5613, CP 5613 A2,<br />

CP 5613 FO, CP 5614,<br />

CP 5614 A2;<br />

German/English<br />

Single license for 1 installation D 6GK1 713-5FB71-3AA0<br />

Software Update Service<br />

Software Update Service for<br />

1 year, with automatic extension;<br />

Prerequisition: current software<br />

version<br />

Upgrade<br />

D 6GK1 713-5FB00-3AL0<br />

from Edition 2006 or 2007 to<br />

FMS-5613 Edition 2008<br />

D 6GK1 713-5FB00-3AE0<br />

from V6.0, V6.1, V6.2 or V6.3 to D<br />

FMS-5613 Edition 2008<br />

6GK1 713-5FB00-3AE1<br />

PROFIBUS FC Standard<br />

Cable GP<br />

Standard type with special design<br />

for quick assembly, 2-core,<br />

shielded,<br />

sold in meters;<br />

delivery unit max. 1000 m,<br />

minimum order 20 m<br />

6XV1 830-0EH10<br />

PROFIBUS FastConnect bus<br />

connector<br />

RS485 Plug 1<strong>80</strong><br />

With 1<strong>80</strong>° cable outlet, insulation<br />

displacement<br />

6GK1 500-0FC10<br />

PROFIBUS bus terminal 12M<br />

Bus terminal for connection of<br />

PROFIBUS stations up to<br />

12 Mbit/s with plug-in cable<br />

1.5 m long<br />

6GK1 500-0AA10<br />

PROFIBUS FastConnect<br />

Stripping Tool<br />

Preset stripping tool for fast<br />

stripping of PROFIBUS<br />

FastConnect bus cables<br />

6GK1 905-6AA00<br />

<strong>Siemens</strong> AG<br />

Contact<br />

Your IT4Industry Team<br />

Werner-von-<strong>Siemens</strong>-Str. 60<br />

91052 Erlangen, Germany<br />

Tel.: +49(0)9131/7-4 61 11<br />

Fax: +49(0)9131/7-4 47 57<br />

E-mail: it4industry@siemens.com


■ Overview<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<br />

<strong>PC</strong>-based Automation<br />

Communication — PROFIBUS<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

CP 5614 A2<br />

■ Ordering data Order No.<br />

CP 5614 A2 communication<br />

processor<br />

<strong>PC</strong>I card (32-bit; 3.3 V/5 V)<br />

master and slave interface to<br />

PROFIBUS including DP-Base<br />

software with NCM <strong>PC</strong>; DP-RAM<br />

interface for DP master, including<br />

PG and FDL protocol; single<br />

license for 1 installation, runtime<br />

software, software and electronic<br />

manual on CD-ROM, Class A,<br />

operating system support see<br />

SIMATIC NET software;<br />

German/English<br />

6GK1 561-4AA01<br />

Software Upgrade<br />

for CP 5614 A2 and CP 5624 on<br />

Edition 2008 or V8.1<br />

6GK1 561-3AA01-3AE0<br />

<br />

HARDNET-PB DP<br />

Development Kit<br />

Software development kit<br />

HARDNET-PB DP<br />

for CP 5613/CP 5614/<br />

CP 5613 A2/CP 5614 A2/<br />

CP 5613 FO for integration in<br />

other operating system environ-<br />

see<br />

www.siemens.com/<br />

simatic-net/dk5613<br />

<strong>PC</strong>I card (Universal keyed 5 V/3.3 V) with own microprocessor<br />

for connection of <strong>PC</strong>s and SIMATIC PG/<strong>PC</strong> to PROFIBUS at up<br />

ments on systems with a <strong>PC</strong>I slot<br />

HARDNET-PB DP<br />

to 12 Mbit/s<br />

Software for DP, incl. PG and FDL<br />

Communication services:<br />

- PROFIBUS DP master and slave interface according to<br />

IEC 61158/61784 on one <strong>PC</strong>I card<br />

- PG/OP communication with <strong>ST</strong>EP 5 and <strong>ST</strong>EP 7<br />

- S7 communication with HARDNET S7 software package<br />

- Open communication (SEND/RECEIVE) based on the<br />

protocol, O<strong>PC</strong> server and<br />

NCM <strong>PC</strong>; runtime software,<br />

software and electronic manual<br />

on CD-ROM, license key on<br />

USB flash drive, Class A; for<br />

CP 5603, CP 5613 A2, CP 5623,<br />

CP 5614, CP 5614 A2, CP 5624;<br />

FDL interface<br />

- PROFIBUS FMS according to IEC 61158/61784 with<br />

FMS-5613 software package<br />

Comprehensive diagnostics possibilities for installation,<br />

commissioning and operation of the module<br />

HARDNET-PB DP V8.1<br />

for 32/64 bit:<br />

Windows 7 Professional/Ultimate;<br />

for 64 bit:<br />

Windows 2008 Server R2<br />

High performance over direct dual-port RAM access<br />

English/German<br />

Event and filter mechanisms to reduce the loading on the<br />

host CPU<br />

Single license for 1 installation<br />

DP-5613 Edition 2008<br />

D 6GK1 713-5DB08-1AA0<br />

Multiprotocol operation and parallel operation of up to<br />

for 32 bit Windows XP Profes-<br />

four CPs<br />

Implementation of Motion Control applications is possible<br />

because a constant bus cycle time is supported<br />

sional SP2/3; Windows 2003<br />

Server R2, SP2; Windows Vista<br />

Business/Ultimate SP1;<br />

Windows 2008 Server;<br />

The appropriate O<strong>PC</strong> servers and configuration tools are English/German<br />

included in the scope of supply of the respective<br />

Single license for 1 installation D 6GK1 713-5DB71-3AA0<br />

communication software<br />

Software Update Service<br />

Software Update Service for<br />

1 year, with automatic extension;<br />

requirement: current software<br />

version<br />

Upgrade<br />

D 6GK1 713-5DB00-3AL0<br />

from Edition 2006 or 2007 to<br />

DP-5613 Edition 2008 or<br />

HARDNET DP V8.1<br />

D 6GK1 713-5DB00-3AE0<br />

from V6.0, V6.1, V6.2 or V6.3 to D<br />

DP-5613 Edition 2008 or<br />

HARDNET DP V8.1<br />

6GK1 713-5DB00-3AE1<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

5/329<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Communication — PROFIBUS<br />

CP 5614 A2<br />

■ Ordering data Order No. Order No.<br />

HARDNET-PB S7<br />

Software Update Service D 6GK1 713-5FB00-3AL0<br />

Software for S7 communication,<br />

incl. PG and FDL protocol,<br />

O<strong>PC</strong> server and NCM <strong>PC</strong>; runtime<br />

software, software and electronic<br />

Software Update Service for<br />

1 year, with automatic extension;<br />

requirement: current software<br />

version<br />

manual on USB flash drive,<br />

Class A; for CP 5603,<br />

CP 5613 A2, CP 5623,<br />

CP 5614 A2, CP 5624;<br />

Upgrade<br />

from Edition 2006 or 2007 to D<br />

FMS-5613 Edition 2008<br />

from V6.0, V6.1, V6.2 or V6.3 to D<br />

6GK1 713-5FB00-3AE0<br />

6GK1 713-5FB00-3AE1<br />

S7-5613 Edition 2008<br />

FMS-5613 Edition 2008<br />

for 32 bit Windows XP Profes-<br />

PROFIBUS FC Standard Cable 6XV1 830-0EH10<br />

sional SP2/3; Windows 2003<br />

GP<br />

Server R2, SP2; Windows Vista<br />

Business/Ultimate SP1;<br />

Windows 2008 Server;<br />

English/German<br />

Single license for 1 installation D 6GK1 713-5CB71-3AA0<br />

Standard type with special design<br />

for quick assembly, 2-core,<br />

shielded,<br />

sold in meters;<br />

delivery unit max. 1000 m,<br />

Software Update Service<br />

minimum order 20 m<br />

Software Update Service for D<br />

1 year, with automatic extension;<br />

requirement: Current software<br />

version<br />

Upgrade<br />

from Edition 2006 or 2007 to D<br />

6GK1 713-5CB00-3AL0<br />

6GK1 713-5CB00-3AE0<br />

PROFIBUS FastConnect bus<br />

connector RS485 Plug 1<strong>80</strong><br />

With 1<strong>80</strong>° cable outlet, insulation<br />

displacement<br />

PROFIBUS bus terminal 12M<br />

6GK1 500-0FC10<br />

6GK1 500-0AA10<br />

S7-5613 Edition 2008 or<br />

HARDNET S7 V8.1<br />

Bus terminal for connection of<br />

PROFIBUS stations up to<br />

from V6.0, V6.1, V6.2 or V6.3 to D 6GK1 713-5CB00-3AE1<br />

12 Mbit/s with plug-in cable<br />

S7-5613 Edition 2008 or<br />

1.5 m long<br />

HARDNET S7 V8.1<br />

PROFIBUS FastConnect<br />

6GK1 905-6AA00<br />

FMS-5613 Edition 2008<br />

Stripping Tool<br />

Software for FMS protocol,<br />

Preinstalled stripping tool for fast<br />

including PG/OP communication,<br />

stripping of PROFIBUS<br />

FDL, FMS-O<strong>PC</strong> server and<br />

NCM <strong>PC</strong>; runtime software,<br />

software and electronic manual<br />

on USB flash drive, Class A for<br />

32 bit Windows XP Professional<br />

SP2/3, Windows 2003 Server R2,<br />

SP2, Windows Vista Business/<br />

Ultimate SP1; Windows 2008<br />

Server; for CP 5613, CP 5613 A2,<br />

CP 5613 FO, CP 5614,<br />

CP 5614 A2,<br />

German/English<br />

FastConnect bus cables<br />

Single license for 1 installation D 6GK1 713-5FB71-3AA0<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

■ More information<br />

You can find the HARDNET DP Development Kit on the Internet<br />

www.siemens.com/simatic-net/dk5613<br />

5/330<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Overview<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<br />

<strong>PC</strong>-based Automation<br />

Communication — PROFIBUS<br />

■ Ordering data Order No.<br />

CP 5623 communication<br />

processor<br />

<strong>PC</strong>I Express x1 card (32 bit) for<br />

connection to PROFIBUS incl.<br />

DP-Base software with NCM <strong>PC</strong>;<br />

DP-RAM interface for DP master<br />

or DP slave, incl. PG and FDL<br />

protocols; single license for<br />

1 installation, runtime software,<br />

software and electronic manual<br />

on CD-ROM, Class A, for<br />

operating system support see<br />

SIMATIC NET software;<br />

German/English<br />

E 6GK1 562-3AA00<br />

Software Upgrade<br />

for CP 5603, CP 5613 A2 and<br />

CP 5623 on Edition 2008 or V8.1<br />

6GK1 561-3AA01-3AE0<br />

<br />

Development Kit<br />

HARDNET-PB DP<br />

Software development kit<br />

HARDNET DP for CP 5603,<br />

CP 5613, CP 5613 A2, CP 5623,<br />

CP 5613 FO, CP 5614,<br />

CP 5614 A2, CP 5624;<br />

for integration into other operating<br />

see<br />

www.siemens.com/<br />

simatic-net/dk5613<br />

<strong>PC</strong>I Express card (<strong>PC</strong>Ie x1) with own microprocessor for<br />

connecting <strong>PC</strong>s and SIMATIC PG/<strong>PC</strong> to PROFIBUS at up to<br />

12 Mbit/s<br />

system environments on systems<br />

with a <strong>PC</strong>I or <strong>PC</strong>I Express slot<br />

HARDNET-PB DP<br />

Communication services:<br />

- PROFIBUS DP master Class 1 and 2 or DP slave according<br />

to IEC 61158/61784 on a <strong>PC</strong>I card<br />

- PG/OP communication with <strong>ST</strong>EP 5 and <strong>ST</strong>EP 7<br />

- S7 communication with HARDNET S7 software package<br />

- Open communication (SEND/RECEIVE) based on the<br />

FDL interface<br />

Software for DP, incl. PG and FDL<br />

protocol, O<strong>PC</strong> server and<br />

NCM <strong>PC</strong>; runtime software,<br />

software and electronic manual<br />

on CD-ROM, license key on<br />

USB flash drive, Class A;<br />

for CP 5603, CP 5613 A2,<br />

CP 5623, CP 5614 A2, CP 5624;<br />

- PROFIBUS FMS according to IEC 61158/61784 with<br />

FMS-5613 software package<br />

Extensive diagnostic options for installation, commissioning<br />

and operation of the module<br />

HARDNET-PB DP V8.1<br />

for 32/64 bit:<br />

Windows 7 Professional/Ultimate;<br />

for 64 bit:<br />

Event and filter mechanism for reducing the load on the<br />

host CPU<br />

Multiprotocol operation and parallel operation of up to<br />

four CPs<br />

Windows 2008 Server R2<br />

English/German<br />

Single license for 1 installation<br />

DP-5613 Edition 2008<br />

D 6GK1 713-5DB08-1AA0<br />

The appropriate O<strong>PC</strong> servers and configuration tools are for 32 bit Windows XP Profes-<br />

included in the scope of supply of the respective<br />

communication software<br />

sional SP2/3; Windows 2003<br />

Server R2, SP2; Windows Vista<br />

Business/Ultimate SP1;<br />

Windows 2008 Server;<br />

English/German<br />

Single license for 1 installation D 6GK1 713-5DB71-3AA0<br />

Software Update Service<br />

Software Update Service for<br />

1 year, with automatic extension;<br />

requirement: current software<br />

version<br />

Upgrade<br />

D 6GK1 713-5DB00-3AL0<br />

from Edition 2006 or 2007 to<br />

DP-5613 Edition 2008 or<br />

HARDNET DP V8.1<br />

D 6GK1 713-5DB00-3AE0<br />

from V6.0, V6.1, V6.2 or V6.3 to D<br />

DP-5613 Edition 2008 or<br />

HARDNET DP V8.1<br />

6GK1 713-5DB00-3AE1<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

CP 5623<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

5/331<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Communication — PROFIBUS<br />

CP 5623<br />

■ Ordering data Order No. Order No.<br />

HARDNET-PB S7<br />

Software for S7 communication,<br />

incl. PG and FDL protocol,<br />

O<strong>PC</strong> server and NCM <strong>PC</strong>; runtime<br />

software, software and electronic<br />

manual on USB flash drive,<br />

Class A; for CP 5603,<br />

CP 5613 A2, CP 5623,<br />

CP 5614 A2, CP 5624<br />

HARDNET-PB S7 V8.1<br />

for 32/64 bit:<br />

Windows 7 Professional/Ultimate;<br />

for 64 bit:<br />

Windows 2008 Server R2<br />

English/German<br />

Single license for 1 installation<br />

S7-5613 Edition 2008<br />

for 32 bit Windows XP Professional<br />

SP2/3; Windows 2003<br />

Server R2, SP2; Windows Vista<br />

Business/Ultimate SP1;<br />

Windows 2008 Server;<br />

English/German<br />

D 6GK1 713-5CB08-1AA0<br />

Single license for 1 installation D 6GK1 713-5CB71-3AA0<br />

Software Update Service<br />

Software Update Service for<br />

1 year,<br />

with automatic extension;<br />

requirement: current software<br />

version<br />

Upgrade<br />

D 6GK1 713-5CB00-3AL0<br />

from Edition 2006 or 2007 to<br />

S7-5613 Edition 2008 or<br />

HARDNET S7 V8.1<br />

D 6GK1 713-5CB00-3AE0<br />

from V6.0, V6.1, V6.2 or V6.3 to D<br />

S7-5613 Edition 2008 or<br />

HARDNET S7 V8.1<br />

6GK1 713-5CB00-3AE1<br />

FMS-5613 Edition 2008<br />

Software for FMS protocol incl.<br />

PG/OP communication; FDL,<br />

FMS-O<strong>PC</strong> server and NCM <strong>PC</strong>;<br />

runtime software, software and<br />

electronic manual on USB stick,<br />

Class A, for 32-bit Windows XP<br />

Professional SP2/3;<br />

Windows 2003 Server R2, SP2;<br />

Windows Vista Business/<br />

Ultimate SP1;<br />

Windows 2008 Server; for<br />

CP 5603, CP 5613, CP 5613 A2,<br />

CP 5623, CP 5613 FO, CP 5614,<br />

CP 5614 A2, CP 5624;<br />

German/English<br />

Single license for 1 installation D 6GK1 713-5FB71-3AA0<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

■ More information<br />

You can find the HARDNET-PB DP Development Kit on the<br />

Internet.<br />

You will find more information on the Internet:<br />

www.siemens.com/simatic-net/dk5613<br />

The CP 5623 module can also be used under LINUX and UNIX<br />

operating systems. Find out more about the available LINUX<br />

distributors and UNIX operating systems from:<br />

5/332<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Software Update Service<br />

Software Update Service for<br />

1 year,<br />

with automatic extension;<br />

requirement: current software<br />

version<br />

Upgrade<br />

D 6GK1 713-5FB00-3AL0<br />

from Edition 2006 or 2007 to<br />

FMS-5613 Edition 2008<br />

D 6GK1 713-5FB00-3AE0<br />

V6.0, V6.1, V6.2 or V6.3 to<br />

FMS-5613 Edition 2008<br />

D 6GK1 713-5FB00-3AE1<br />

PROFIBUS FC Standard Cable<br />

GP<br />

Standard type with special design<br />

for quick assembly, 2-core,<br />

shielded,<br />

sold in meters;<br />

delivery unit max. 1000 m,<br />

minimum order 20 m<br />

6XV1 830-0EH10<br />

PROFIBUS FastConnect bus<br />

connector<br />

RS485 Plug 1<strong>80</strong><br />

With 1<strong>80</strong>° cable outlet, insulation<br />

displacement<br />

6GK1 500-0FC10<br />

PROFIBUS bus terminal 12M<br />

Bus terminal for connection of<br />

PROFIBUS stations up to<br />

12 Mbit/s with plug-in cable<br />

1.5 m long<br />

6GK1 500-0AA10<br />

PROFIBUS FastConnect<br />

Stripping Tool<br />

Preset stripping tool for fast<br />

stripping of PROFIBUS<br />

FastConnect bus cables<br />

6GK1 905-6AA00<br />

<strong>Siemens</strong> AG<br />

Contact<br />

Your IT4Industry Team<br />

Werner-von-<strong>Siemens</strong>-Str. 60<br />

91052 Erlangen, Germany<br />

Tel.: +49(0)9131/7-4 61 11<br />

Fax: +49(0)9131/7-4 47 57<br />

E-mail: it4industry@siemens.com


■ Overview<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<br />

<strong>PC</strong>-based Automation<br />

Communication — PROFIBUS<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

CP 5624<br />

■ Ordering data Order No.<br />

CP 5624 A2 communication<br />

processor<br />

<strong>PC</strong>I Express x1 card (32 bit) for<br />

master and slave connection to<br />

PROFIBUS incl. DP-Base<br />

software with NCM <strong>PC</strong>; DP-RAM<br />

interface for DP master, incl. PG<br />

and FDL protocols; single license<br />

for 1 installation, runtime software,<br />

software and electronic manual<br />

on CD-ROM, Class A, for<br />

operating system support see<br />

SIMATIC NET software;<br />

German/English<br />

E 6GK1 562-4AA00<br />

Software upgrade<br />

for CP 5614 A2 and CP 5624 to<br />

Edition 2008 or V8.1<br />

6GK1 561-3AA01-3AE0<br />

<br />

HARDNET-PB DP<br />

Development Kit<br />

Software development kit<br />

HARDNET-PB DP<br />

for CP 5603, CP 5613, CP<br />

5613 A2, CP 5623, CP 5613 FO,<br />

CP 5614, CP 5614 A2, CP 5624;<br />

for integration into other operating<br />

see<br />

www.siemens.com/<br />

simatic-net/dk5613<br />

<strong>PC</strong>I Express card (<strong>PC</strong>Ie x1) with own microprocessor for<br />

connecting <strong>PC</strong>s and SIMATIC PG/<strong>PC</strong> to PROFIBUS at up to<br />

12 Mbit/s<br />

system environments on systems<br />

with a <strong>PC</strong>I or <strong>PC</strong>I Express slot<br />

HARDNET-PB DP<br />

Two 9-pin sub-D sockets for parallel operation as DP master<br />

and DP slave<br />

Communication services:<br />

- PROFIBUS DP master and slave interface according to<br />

Software for DP, incl. PG and FDL<br />

protocol, O<strong>PC</strong> server and<br />

NCM <strong>PC</strong>; runtime software,<br />

software and electronic manual<br />

on CD-ROM, license key on<br />

IEC 61158/61784 on one <strong>PC</strong>I card<br />

USB flash drive, Class A;<br />

- PG/OP communication with <strong>ST</strong>EP 5 and <strong>ST</strong>EP 7<br />

- S7 communication with HARDNET S7 software package<br />

for CP 5603, CP 5613 A2,<br />

CP 5623, CP 5614 A2, CP 5624;<br />

- Open communication (SEND/RECEIVE) based on the<br />

HARDNET-PB DP V8.1<br />

FDL interface<br />

- PROFIBUS FMS according to IEC 61158/61784 with<br />

FMS-5613 software package<br />

for 32/64 bit:<br />

Windows 7 Professional/Ultimate;<br />

for 64 bit:<br />

Extensive diagnostic options for installation, commissioning<br />

and operation of the module<br />

Event and filter mechanism for reducing the load on the<br />

host CPU<br />

Windows 2008 Server R2<br />

English/German<br />

Single license for 1 installation<br />

DP-5613, 2008 Edition<br />

D 6GK1 713-5DB08-1AA0<br />

Multiprotocol operation and parallel operation of up to four for 32 bit Windows XP Profes-<br />

CPs<br />

The appropriate O<strong>PC</strong> servers and configuration tools are<br />

included in the scope of supply of the respective<br />

communication software<br />

sional SP2/3; Windows 2003<br />

Server R2, SP2; Windows Vista<br />

Business/Ultimate SP1;<br />

Windows 2008 Server;<br />

English/German<br />

Single license for 1 installation D 6GK1 713-5DB71-3AA0<br />

Software Update Service<br />

Software Update Service for<br />

1 year,<br />

with automatic extension;<br />

requirement: current software<br />

version<br />

Upgrade<br />

D 6GK1 713-5DB00-3AL0<br />

from Edition 2006 or 2007 to<br />

DP-5613 Edition 2008 or<br />

HARDNET DP V8.1<br />

D 6GK1 713-5DB00-3AE0<br />

from V6.0, V6.1, V6.2 or V6.3 to D<br />

DP-5613 Edition 2008 or<br />

HARDNET DP V8.1<br />

6GK1 713-5DB00-3AE1<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

5/333<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Communication — PROFIBUS<br />

CP 5624<br />

■ Ordering data Order No. Order No.<br />

HARDNET-PB S7<br />

Software for S7 communication,<br />

incl. PG and FDL protocol, O<strong>PC</strong><br />

server and NCM <strong>PC</strong>; runtime<br />

software, software and electronic<br />

manual on USB flash drive,<br />

Class A; for CP 5603,<br />

CP 5613 A2, CP 5623,<br />

CP 5614 A2, CP 5624;<br />

HARDNET-PB S7 V8.1<br />

for 32/64 bit:<br />

Windows 7 Professional/Ultimate;<br />

for 64 bit:<br />

Windows 2008 Server R2<br />

English/German<br />

Single license for 1 installation<br />

D 6GK1 713-5CB08-1AA0<br />

S7-5613 Edition 2008<br />

for 32 bit Windows XP Professional<br />

SP2/3; Windows 2003<br />

Server R2, SP2; Windows Vista<br />

Business/Ultimate SP1;<br />

Windows 2008 Server;<br />

English/German<br />

Single license for 1 installation D 6GK1 713-5CB71-3AA0<br />

Software Update Service<br />

Software Update Service for<br />

1 year,<br />

with automatic extension;<br />

requirement: current software<br />

version<br />

Upgrade<br />

D 6GK1 713-5CB00-3AL0<br />

from Edition 2006 or 2007 to<br />

S7-5613 Edition 2008 or<br />

HARDNET S7 V8.1<br />

D 6GK1 713-5CB00-3AE0<br />

from V6.0, V6.1, V6.2 or V6.3 to D<br />

S7-5613 Edition 2008 or<br />

HARDNET S7 V8.1<br />

6GK1 713-5CB00-3AE1<br />

■ More information<br />

You can find the HARDNET-PB DP Development Kit on the<br />

Internet.<br />

You can find more information on the Internet:<br />

www.siemens.com/simatic-net/dk5613<br />

5/334<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

FMS-5613 Edition 2008<br />

Software for FMS protocol incl.<br />

PG/OP communication; FDL,<br />

FMS-O<strong>PC</strong> server and NCM <strong>PC</strong>;<br />

runtime software, software and<br />

electronic manual on USB stick,<br />

Class A, for 32-bit Windows XP<br />

Professional SP2/3; Windows<br />

2003 Server R2, SP2; Windows<br />

Vista Business/Ultimate SP1;<br />

Windows 2008 Server;<br />

for CP 5603, CP 5613,<br />

CP 5613 A2, CP 5623,<br />

CP 5613 FO, CP 5614,<br />

CP 5614 A2, CP 5624;<br />

German/English<br />

Single license for 1 installation D 6GK1 713-5FB71-3AA0<br />

Software Update Service<br />

Software Update Service for<br />

1 year,<br />

with automatic extension;<br />

requirement: current software<br />

version<br />

Upgrade<br />

D 6GK1 713-5FB00-3AL0<br />

from Edition 2006 or 2007 to<br />

FMS-5613 Edition 2008<br />

D 6GK1 713-5FB00-3AE0<br />

from V6.0, V6.1, V6.2 or V6.3 to D<br />

FMS-5613<br />

Edition 2008<br />

6GK1 713-5FB00-3AE1<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU


■ Overview<br />

<br />

<br />

<br />

<br />

<br />

<br />

<strong>PC</strong> Card Type II (CardBus 32 bit) to connect PG/<strong>PC</strong> and<br />

notebooks with <strong>PC</strong> card slot (CardBus 32 bit) to PROFIBUS<br />

and to the MPI of the SIMATIC S7<br />

Communication services:<br />

- PROFIBUS DP Master Class 1 incl. acyclic DP expansions<br />

with SOFTNET-DP software package<br />

- PROFIBUS DP Master Class 2 incl. acyclic DP expansions<br />

with SOFTNET-DP software package<br />

- PROFIBUS DP slave with SOFTNET-DP Slave software<br />

package<br />

- PG/OP communication with <strong>ST</strong>EP 5 or <strong>ST</strong>EP 7<br />

- S7 communication with SOFTNET-S7 software package<br />

- Open communication (SEND/RECEIVE on basis of the<br />

FDL interface) with SOFTNET-DP or SOFTNET-S7 software<br />

package<br />

Can be used with:<br />

- <strong>ST</strong>EP 7 and NCM <strong>PC</strong>; (ProTool, Micro/Win, ProTool/Pro,<br />

SIMATIC PDM for PG/OP communication)<br />

- SOFTNET-S7 (for S7 communication)<br />

- SOFTNET-DP, SOFTNET-DP slave (for DP)<br />

The appropriate O<strong>PC</strong> servers are included in the scope of<br />

supply of the respective communication software<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<br />

<strong>PC</strong>-based Automation<br />

Communication — PROFIBUS<br />

■ Ordering data Order No.<br />

CP 5512 communication<br />

6GK1 551-2AA00<br />

processor<br />

<strong>PC</strong>-Card (CardBus, 32-bit) for<br />

connection of a programming<br />

device or notebook to PROFIBUS<br />

or MPI, under 32 bit in connection<br />

with PROFIBUS SOFTNET<br />

software or <strong>ST</strong>EP 7;<br />

German/English<br />

SOFTNET-PB S7 see page 5/340<br />

Software for S7 communication,<br />

incl. FDL protocol with O<strong>PC</strong><br />

server and NCM-<strong>PC</strong>, runtime<br />

software, software and electronic<br />

manual on CD-ROM, license key<br />

on USB flash drive, Class A; for<br />

CP 5512, CP 5611, CP 5611 A2,<br />

CP 5711, CP 5621;<br />

SOFTNET-PB DP see page 5/340<br />

Software for DP protocol (master<br />

class 1 and 2), incl. FDL protocol<br />

with O<strong>PC</strong> server and NCM <strong>PC</strong>,<br />

runtime software, software and<br />

electronic manual on CD-ROM,<br />

license key on USB flash drive,<br />

Class A; for CP 5512, CP 5611,<br />

CP 5611 A2, CP 5711, CP 5621;<br />

SOFTNET-PB DP Slave see page 5/340<br />

Software for DP slave, with DP<br />

O<strong>PC</strong> server and NCM <strong>PC</strong>, single<br />

license for 1 installation, runtime<br />

software, software and electronic<br />

manual on CD-ROM, license key<br />

on USB flash drive, Class A; for<br />

CP 5512, CP 5611, CP 5611 A2,<br />

CP 5711, CP 5621;<br />

PROFIBUS FastConnect bus 6GK1 500-0FC10<br />

connector<br />

RS 485 Plug 1<strong>80</strong><br />

With 1<strong>80</strong>° cable outlet<br />

PROFIBUS adapter for CP 5512 C79459-A1890-A10<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

CP 5512<br />

5/335<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Communication — PROFIBUS<br />

CP 5611 A2<br />

■ Overview<br />

<br />

<strong>PC</strong>I card (Universal keyed 5 V/3.3 V) for connecting <strong>PC</strong>s and<br />

SIMATIC PG/<strong>PC</strong> to PROFIBUS at up to 12 Mbit/s and to the<br />

MPI interface of SIMATIC S7<br />

Communication services:<br />

- PROFIBUS DP Master Class 1 incl. acyclic DP expansions<br />

with SOFTNET-DP software package<br />

- PROFIBUS DP Master Class 2 incl. acyclic DP expansions<br />

with SOFTNET-DP software package<br />

- PROFIBUS DP slave with SOFTNET-DP Slave software<br />

package<br />

- PG/OP communication with <strong>ST</strong>EP 5 or <strong>ST</strong>EP 7<br />

- S7 communication with SOFTNET-S7 software package<br />

- Open communication (SEND/RECEIVE on basis of the<br />

FDL interface) with SOFTNET-DP or SOFTNET-S7 software<br />

package<br />

Can be used with:<br />

- <strong>ST</strong>EP 7, <strong>ST</strong>EP 7-Micro/Win, ProTool, ProTool/Pro,<br />

SIMATIC PDM (for PG/OP communication)<br />

- COM PROFIBUS<br />

- SOFTNET-S7 (for S7 communication)<br />

- SOFTNET-DP, SOFTNET-DP slave (for DP)<br />

The appropriate O<strong>PC</strong> servers and configuration tools are<br />

included in the scope of supply of the respective<br />

communication software.<br />

5/336<br />

<br />

<br />

<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<br />

<br />

■ Ordering data<br />

CP 5611 A2 communication<br />

processor<br />

Order No.<br />

<strong>PC</strong>I card (32-bit)<br />

for connection of a PG or <strong>PC</strong><br />

to PROFIBUS<br />

6GK1 561-1AA01<br />

<strong>PC</strong>I card (32-bit)<br />

CP 5611 A2 and MPI cable, 5 m<br />

A 6GK1 561-1AM01<br />

SOFTNET-PB S7<br />

Software for S7 communication,<br />

incl. FDL protocol with O<strong>PC</strong><br />

server and NCM-<strong>PC</strong>, runtime<br />

software, software and electronic<br />

manual on CD-ROM, license key<br />

on USB flash drive, Class A; for<br />

CP 5512, CP 5611, CP 5611 A2,<br />

CP 5711, CP 5621<br />

see page 5/340<br />

SOFTNET-PB DP<br />

Software for DP protocol (master<br />

class 1 and 2), incl. FDL protocol<br />

with O<strong>PC</strong> server and NCM <strong>PC</strong>,<br />

runtime software, software and<br />

electronic manual on CD-ROM,<br />

license key on USB flash drive,<br />

Class A; for CP 5611 A2,<br />

CP 5711, CP 5621;<br />

see page 5/340<br />

SOFTNET-PB DP Slave<br />

Software for DP slave, with DP<br />

O<strong>PC</strong> server and NCM <strong>PC</strong>, single<br />

license for 1 installation, runtime<br />

software, software and electronic<br />

manual on CD-ROM, license key<br />

on USB flash drive, Class A; for<br />

CP 5611 A2, CP 5711, CP 5621;<br />

see page 5/340<br />

PROFIBUS FastConnect bus<br />

connector<br />

RS 485 Plug 1<strong>80</strong><br />

With 1<strong>80</strong>° cable outlet<br />

6GK1 500-0FC10<br />

PROFIBUS bus terminal 12M<br />

Bus terminal for connection of<br />

PROFIBUS stations for up to<br />

12 Mbit/s with plug-in cable<br />

6GK1 500-0AA10<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H


■ Overview<br />

<br />

<br />

<br />

<br />

<br />

<br />

<strong>PC</strong>I Express card (<strong>PC</strong>Ie x1) for connection of <strong>PC</strong>s and<br />

SIMATIC PG/<strong>PC</strong> to PROFIBUS at up to 12 Mbit/s and to the<br />

MPI of the SIMATIC S7<br />

Communication services:<br />

- PROFIBUS DP Master Class 1 incl. acyclic DP expansions<br />

with SOFTNET-DP software package<br />

- PROFIBUS DP Master Class 2 incl. acyclic DP expansions<br />

with SOFTNET-DP software package<br />

- PROFIBUS DP slave with SOFTNET-DP Slave software<br />

package<br />

- PG/OP communication with <strong>ST</strong>EP 5 or <strong>ST</strong>EP 7<br />

- S7 communication with SOFTNET-S7 software package<br />

- Open communication (SEND/RECEIVE on basis of the FDL<br />

interface) with SOFTNET-DP or SOFTNET-S7 software<br />

package<br />

Can be used with:<br />

- <strong>ST</strong>EP 7, <strong>ST</strong>EP 7-Micro/Win, ProTool, ProTool/Pro,<br />

SIMATIC PDM (for PG/OP communication)<br />

- COM PROFIBUS<br />

- SOFTNET-S7 (for S7 communication)<br />

- SOFTNET-DP, SOFTNET-DP slave (for DP)<br />

The appropriate O<strong>PC</strong> server and configuration tools are<br />

included in the scope of supply of the respective<br />

communication software<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<br />

<strong>PC</strong>-based Automation<br />

Communication — PROFIBUS<br />

■ Ordering data<br />

CP 5621 communication<br />

processor<br />

Order No.<br />

<strong>PC</strong>I Express x1 card (32-bit) for E<br />

connection of a PG or <strong>PC</strong> to<br />

PROFIBUS<br />

6GK1 562-1AA00<br />

<strong>PC</strong>I Express x1 card (32-bit)<br />

CP 5621 and MPI cable, 5 m<br />

E 6GK1 562-1AM00<br />

SOFTNET-PB S7<br />

Software for S7 communication,<br />

incl. FDL protocol with O<strong>PC</strong><br />

server and NCM-<strong>PC</strong>, runtime<br />

software, software and electronic<br />

manual on CD-ROM, license key<br />

on USB flash drive, Class A; for<br />

CP 5611 A2, CP 5711, CP 5621<br />

see page 5/340<br />

SOFTNET-PB DP<br />

Software for DP protocol (master<br />

class 1 and 2), incl. FDL protocol<br />

with O<strong>PC</strong> server and NCM <strong>PC</strong>,<br />

runtime software, software and<br />

electronic manual on CD-ROM,<br />

license key on USB flash drive,<br />

Class A; for CP 5611 A2,<br />

CP 5711, CP 5621<br />

see page 5/340<br />

SOFTNET-PB DP slave<br />

Software for DP slave, with DP<br />

O<strong>PC</strong> server and NCM <strong>PC</strong>, single<br />

license for 1 installation, runtime<br />

software, software and electronic<br />

manual on CD-ROM, license key<br />

on USB flash drive, Class A; for<br />

CP 5611 A2, CP 5711, CP 5621<br />

see page 5/340<br />

PROFIBUS FastConnect bus<br />

connector<br />

RS 485 Plug 1<strong>80</strong><br />

With 1<strong>80</strong>° cable outlet<br />

6GK1 500-0FC10<br />

PROFIBUS bus terminal 12M<br />

Bus terminal for connection of<br />

PROFIBUS stations for up to<br />

12 Mbit/s with plug-in cable<br />

6GK1 500-0AA10<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

CP 5621<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

5/337<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Communication — PROFIBUS<br />

CP 5711<br />

■ Overview<br />

<br />

5/338<br />

<br />

<br />

<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

<br />

<br />

USB adapter for the connection of <strong>PC</strong>s and SIMATIC PG/<strong>PC</strong> to<br />

PROFIBUS DP or MPI via USB 2.0<br />

Operation in extended temperature range of -20 °C to +60 °C<br />

Active PROFIBUS termination to supply the PROFIBUS<br />

network as end station of a segment<br />

Rugged USB connection due to mechanical locking of the<br />

USB connector to the CP 5711 enclosure<br />

Communication services:<br />

- PROFIBUS DP master Class 1 and 2 according to<br />

IEC 61158/61784 with SOFTNET-DP software package<br />

- PROFIBUS DP slave with SOFTNET-DP Slave software<br />

package<br />

- PG/OP communication with <strong>ST</strong>EP 5 or <strong>ST</strong>EP 7 software<br />

package<br />

- S7 communication with SOFTNET-S7 software package<br />

- Open communication (SEND/RECEIVE on basis of the FDL<br />

interface) with SOFTNET-DP or SOFTNET-S7 software<br />

package<br />

PROFIBUS connection with up to 12 Mbit/s<br />

Can be used with:<br />

- <strong>ST</strong>EP 7, <strong>ST</strong>EP 7 Micro/WIN, WinCC/WinCC flexible,<br />

NCM <strong>PC</strong>, SIMATIC PDM (for PG/OP communication)<br />

- SOFTNET-S7 (for S7 communication)<br />

- SOFTNET-DP, SOFTNET-DP slave (for DP)<br />

The appropriate O<strong>PC</strong> servers and configuration tools are<br />

included in the scope of supply of the respective<br />

communication software<br />

■ Ordering data Order No. Order No.<br />

CP 5711 communication<br />

processor<br />

for connection of a programming<br />

device or notebook to PROFIBUS<br />

or MPI, under 32 bit in connection<br />

with PROFIBUS SOFTNET<br />

software or <strong>ST</strong>EP 7;<br />

German/English<br />

USB V2.0 adapter 6GK1 571-1AA00<br />

USB V2.0 adapter CP 5711 and A 6GK1 571-1AM00<br />

MPI cable, 5 m<br />

Mounting rail support for<br />

6GK1 571-1AA00-0AH0<br />

CP 5711<br />

Compartment for CP 5711<br />

enclosure; fastened mechanically<br />

to 35 mm DIN rail<br />

SOFTNET-PB S7 see page 5/340<br />

Software for S7 communication,<br />

incl. FDL protocol with O<strong>PC</strong><br />

server and NCM-<strong>PC</strong>, runtime<br />

software, software and electronic<br />

manual on CD-ROM, license key<br />

on USB flash drive, Class A;<br />

for CP 5611 A2, CP 5711,<br />

CP 5621<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<br />

SOFTNET-PB DP see page 5/340<br />

Software for DP protocol (master<br />

class 1 and 2), incl. FDL protocol<br />

with O<strong>PC</strong> server and NCM <strong>PC</strong>,<br />

runtime software, software and<br />

electronic manual on CD-ROM,<br />

license key on USB flash drive,<br />

for CP 5611 A2, CP 5711,<br />

CP 5621;<br />

SOFTNET-PB DP Slave see page 5/340<br />

Software for DP slave, with DP<br />

O<strong>PC</strong> server and NCM <strong>PC</strong>, single<br />

license for 1 installation, runtime<br />

software, software and electronic<br />

manual on CD-ROM, license key<br />

on USB flash drive, Class A; for<br />

CP 5611 A2, CP 5711, CP 5621;<br />

PROFIBUS FastConnect bus 6GK1 500-0FC10<br />

connector<br />

RS485 Plug 1<strong>80</strong><br />

With 1<strong>80</strong>° cable outlet


■ Overview<br />

<br />

PROFIBUS<br />

S5-115U to S5-155U<br />

with CP 5431 FMS/DP<br />

<br />

S7-1200 with<br />

CM 1242-5 or<br />

CM 1243-5<br />

<br />

S7-300 with CP 342-5<br />

or CP 343-5<br />

<br />

<strong>PC</strong>/I<strong>PC</strong> with<br />

CP 5611 A2/<br />

CP 5621/CP 5512<br />

and SOFTNET for<br />

PROFIBUS<br />

S7-400 with<br />

CP 443-5<br />

<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<br />

G_IK10_XX_50039<br />

<br />

<strong>PC</strong>-based Automation<br />

Communication — PROFIBUS<br />

SOFTNET for PROFIBUS<br />

Software for coupling <strong>PC</strong>s/PGs and notebooks to automation<br />

systems<br />

Communication services:<br />

- PROFIBUS DP master Class 1 and 2 with acyclic expansions<br />

- PROFIBUS DP slave<br />

- PG/OP communication<br />

- S7 communication<br />

- Open communication (SEND/RECEIVE) based on the<br />

FDL interface<br />

The appropriate O<strong>PC</strong> servers are included in the scope of<br />

supply of the respective communication software<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/339<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Communication — PROFIBUS<br />

SOFTNET for PROFIBUS<br />

■ Ordering data Order No. Order No.<br />

SOFTNET-PB S7<br />

SOFTNET-DP Edition 2008 (V7.1)<br />

Software for S7 communication,<br />

for Windows XP Professional SP2/<br />

incl. FDL protocol with O<strong>PC</strong> server<br />

3; Windows 2003 Server R2, SP2;<br />

and NCM-<strong>PC</strong>, runtime software,<br />

Windows Vista Business/Ultimate<br />

software and electronic manual on<br />

SP1; Windows 2008 Server;<br />

CD-ROM, license key on USB flash<br />

English/German<br />

drive, Class A; for CP 5611 A2,<br />

CP 5711, CP 5621<br />

SOFTNET-PB S7 V8.1<br />

for 32/64 bit:<br />

Windows 7 Professional/Ultimate;<br />

for 64 bit:<br />

Windows 2008 Server R2<br />

English/German<br />

Single license for 1 installation<br />

Software Update Service<br />

Software Update Service for<br />

1 year, with automatic extension;<br />

requirement: current software<br />

version<br />

Upgrade<br />

D<br />

D<br />

6GK1 704-5DW71-3AA0<br />

6GK1 704-5DW00-3AL0<br />

Single license for 1 installation D<br />

SOFTNET-S7 Edition 2008 (V7.1)<br />

6GK1 704-5CW08-1AA0<br />

from Edition 2006 or higher to<br />

SOFTNET-DP Edition 2008 or<br />

V8.1<br />

D 6GK1 704-5DW00-3AE0<br />

for 32 bit Windows XP Professional<br />

from V6.0, V6.1, V6.2 or V6.3 to D 6GK1 704-5DW00-3AE1<br />

SP2/3; Windows 2003 Server R2,<br />

SOFTNET-DP Edition 2008 or<br />

SP2; Windows Vista Business/<br />

V8.1<br />

Ultimate SP1; Windows 2008<br />

Server; English/German<br />

SOFTNET-PB DP Slave<br />

Single license for 1 installation<br />

Software Update Service<br />

D<br />

D<br />

6GK1 704-5CW71-3AA0<br />

6GK1 704-5CW00-3AL0<br />

Software for DP slave, with DP<br />

O<strong>PC</strong> server and NCM <strong>PC</strong>, single<br />

license for 1 installation, runtime<br />

Software Update Service for<br />

1 year, with automatic extension;<br />

Prerequisition: Current software<br />

version<br />

software, software and electronic<br />

manual on CD-ROM, license key<br />

on USB flash drive, Class A; for<br />

CP 5611 A2, CP 5711, CP 5621<br />

Upgrade<br />

SOFTNET-PB DP Slave V8.1<br />

from Edition 2006 or higher to D 6GK1 704-5CW00-3AE0<br />

for 32/64 bit:<br />

SOFTNET-S7 Edition 2008 or V8.1<br />

Windows 7 Professional/Ultimate;<br />

from V6.0, V6.1, V6.2 or V6.3 to D<br />

SOFTNET-S7 Edition 2008 or V8.1<br />

SOFTNET-PB DP<br />

6GK1 704-5CW00-3AE1<br />

for 64 bit:<br />

Windows 2008 Server R2<br />

English/German<br />

Single license for 1 installation D 6GK1 704-5SW08-1AA0<br />

Software for DP protocol (master<br />

class 1 and 2), incl. FDL protocol<br />

with O<strong>PC</strong> server and NCM <strong>PC</strong>,<br />

SOFTNET-DP Slave Edition 2008<br />

(V7.1)<br />

runtime software, software and<br />

for 32 bit Windows XP Professional<br />

electronic manual on CD-ROM,<br />

SP2/3; Windows 2003 Server R2,<br />

license key on USB flash drive,<br />

SP2; Windows Vista Business/<br />

for CP 5611 A2, CP 5711, CP 5621<br />

Ultimate SP1; Windows 2008<br />

SOFTNET-PB DP V8.1<br />

Server;<br />

English/German<br />

for 32/64 bit:<br />

Single license for 1 installation D 6GK1 704-5SW71-3AA0<br />

Windows 7 Professional/Ultimate;<br />

for 64 bit:<br />

Software Update Service D 6GK1 704-5SW00-3AL0<br />

Windows 2008 Server R2<br />

English/German<br />

Software Update Service for<br />

1 year, with automatic extension;<br />

Single license for 1 installation D 6GK1 704-5DW08-1AA0<br />

requirement: current software<br />

version<br />

Upgrade<br />

from Edition 2006 or higher to<br />

SOFTNET-DP Slave Edition 2008<br />

or V8.1<br />

D 6GK1 704-5SW00-3AE0<br />

from V6.0, V6.1, V6.2 or V6.3 to<br />

SOFTNET-DP Slave Edition 2008<br />

or V8.1<br />

D 6GK1 704-5SW00-3AE1<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

5/340<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Overview<br />

<strong>PC</strong>/Windows <strong>PC</strong><br />

DP O<strong>PC</strong> server<br />

FMS O<strong>PC</strong> server<br />

DP protocol<br />

FMS protocol<br />

SIMATIC NET<br />

O<strong>PC</strong>-Scout<br />

S7-1200<br />

S7-300<br />

SIMATIC S5<br />

System integration with O<strong>PC</strong> server<br />

O<strong>PC</strong> UA<br />

S7 O<strong>PC</strong> server<br />

S7 communication<br />

WinCC<br />

O<strong>PC</strong>-Client<br />

COM/DCOM<br />

S/R O<strong>PC</strong> server<br />

Open<br />

communication<br />

(SEND/RECEIVE)<br />

Standardized, open multi-vendor interface<br />

Interfacing of O<strong>PC</strong>-capable Windows applications to DP, FMS,<br />

S7 communication and open communication<br />

(SEND/RECEIVE) based on the FDL interface<br />

O<strong>PC</strong> Scout with browser functionality as an O<strong>PC</strong> client and<br />

OCX-Data-Control/.NET Data Control for simple O<strong>PC</strong> client<br />

creation<br />

The relevant O<strong>PC</strong> servers are supplied with each<br />

communication software package<br />

<strong>PC</strong><br />

ET 200pro<br />

PROFIBUS<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

PN IO O<strong>PC</strong> server<br />

PROFINET<br />

PROFINET<br />

Industrial Ethernet<br />

Microsoft Office<br />

O<strong>PC</strong>-Client<br />

<strong>PC</strong>-based Automation<br />

Communication — PROFIBUS<br />

SNMP<br />

O<strong>PC</strong> server<br />

SNMP<br />

<strong>PC</strong><br />

S7-400<br />

O<strong>PC</strong> server for PROFIBUS<br />

O<strong>PC</strong> XML<br />

Webclient<br />

Internet<br />

Intranet<br />

O<strong>PC</strong> XML DA<br />

as Web service<br />

SIMATIC S7-1200<br />

SIMATIC S5<br />

(SEND/RECEIVE only)<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

G_IK10_XX 50700<br />

5/341<br />

5


5<br />

<strong>PC</strong>-based Automation<br />

Communication — PROFIBUS<br />

O<strong>PC</strong> server for PROFIBUS<br />

■ Technical specifications<br />

Programming Synchronous and asynchronous<br />

reading and writing of variables<br />

Monitoring of variables using the<br />

O<strong>PC</strong> server with a signal to the<br />

client when a change occurs<br />

Use of quantity operations; so<br />

a large amount of data can be<br />

processed in a short time.<br />

Interfaces Custom Interface (C++, NET);<br />

for high O<strong>PC</strong> performance<br />

Automation Interface<br />

(VB, Excel, Access, Delphi, ...)<br />

for ease-of-use<br />

Graphics with OCX or .NET Data<br />

Control;<br />

for configuring instead of<br />

programming<br />

O<strong>PC</strong> XML-Interface for Data<br />

Access<br />

Protocols S7 communication<br />

Open communication<br />

(SEND/RECEIVE)<br />

PROFIBUS DP<br />

PROFIBUS FMS<br />

5/342<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Product versions include O<strong>PC</strong> servers for:<br />

HARDNET-PB DP PROFIBUS DP, XML-DA<br />

HARDNET-PB S7 S7 communication, XML-DA<br />

FMS-5613 FMS communication, XML-DA<br />

SOFTNET-PB S7 S7 communication, XML-DA<br />

SOFTNET-PB DP PROFIBUS DP, XML-DA<br />

SOFTNET-PB DP slave PROFIBUS DP slave, XML-DA<br />

CP 5603/CP 5613 A2/CP 5623/ Open communication (FDL)<br />

CP 5614 A2 and CP 5624 with PROFIBUS DP Master,<br />

DP-Base Software<br />

Access to DP-slave of the<br />

CP 5614 A2/CP 5624, XML-DA


■ Overview<br />

O<strong>PC</strong> (Openness, Productivity & Collaboration) is a<br />

standardized, open, and vendor-independent interface that is<br />

widely used in automation. O<strong>PC</strong> UA (Unified Architecture) is the<br />

result of consistent further development of this standard, offering<br />

additional functions such as security or redundancy.<br />

S7 O<strong>PC</strong> Redundancy is a software product compliant with the<br />

O<strong>PC</strong> UA standard that enables the redundant configuration of<br />

O<strong>PC</strong> UA servers to SIMATIC S7. The availability of automation<br />

data to operator control and monitoring systems is guaranteed<br />

thanks to the redundant use of O<strong>PC</strong> UA servers. This requires<br />

neither additional cabling for synchronizing the redundant O<strong>PC</strong><br />

UA servers, nor additional programming overhead in the <strong>PC</strong>.<br />

The O<strong>PC</strong> UA servers are synchronized via high-performance<br />

Industrial Ethernet network access points at 10/100 and<br />

1000 Mbit/s. S7 O<strong>PC</strong> Redundancy represents an integrated<br />

customer solution for all SIMATIC NET S7 SOFTNET and<br />

HARDNET software products in the automation world.<br />

■ Design<br />

S7 O<strong>PC</strong> redundancy<br />

Station A<br />

Industrial Ethernet<br />

Redundant use of O<strong>PC</strong> servers<br />

O<strong>PC</strong> UA<br />

synchronization<br />

Industrial Ethernet<br />

PROFIBUS<br />

HMI<br />

S7 O<strong>PC</strong> redundancy<br />

Station B<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

G_IK10_XX_10295<br />

<strong>PC</strong>-based Automation<br />

Communication — PROFIBUS<br />

S7 O<strong>PC</strong> Redundancy for PROFIBUS<br />

■ Ordering data Order No.<br />

S7 O<strong>PC</strong> Redundancy<br />

Software for redundant O<strong>PC</strong><br />

servers, Runtime software,<br />

software and electronic manual<br />

on CD-ROM, license key on USB<br />

stick, Class A<br />

S7 O<strong>PC</strong> Redundancy V8.1 for<br />

PROFIBUS<br />

for 64-bit Windows 2008<br />

server R2; English/German<br />

Single license for one installationD 6GK1 706-5CW08-1AA0<br />

Software Update Service<br />

for 1 year with automatic<br />

extension;<br />

requirement: current software<br />

version<br />

D 6GK1 706-5CW00-3AL0<br />

D: Subject to export regulations: AL: N and ECCN: 5D992<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

5/343<br />

5


5<br />

Notes<br />

5/344<br />

<strong>PC</strong>-based Automation<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


© <strong>Siemens</strong> AG <strong>2011</strong><br />

Customized Automation<br />

6/2 Customized Automation<br />

6/2 Introduction<br />

6/4 Customized hardware<br />

6/5 Customized hardware<br />

6/5 Design products<br />

6/8 OEM products<br />

6/9 Flexible front design concept<br />

for HMI products<br />

6/11 SIMATIC <strong>PC</strong> function cards<br />

6/12 MP 270 data display<br />

6/13 MP 277 8" Touch control console<br />

6/14 MP 277 8" Touch portrait<br />

6/16 MP 277 6" Touch portrait<br />

6/17 SIMATIC HMI Net Panel<br />

6/21 Panel <strong>PC</strong> 677B with 46"<br />

6/23 Turnkey products<br />

6/24 HMI operator stations<br />

6/26 Rear panel cover<br />

6/28 Customized software<br />

6/29 Remote Operate Software<br />

6/30 SIMATIC KNX/EIB2S7<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6<br />

6/33 Examples of sector products<br />

6/34 Renewable energy<br />

6/34 Solar systems<br />

6/35 Wind farms<br />

6/36 Automotive industry<br />

6/36 HMI operator stations<br />

6/39 PP17 with PROFIBUS and PROFINET<br />

6/43 Front panel with arrow keys on the side<br />

6/45 Mobile Panel 277 10" Remote Operate<br />

6/48 General machine construction<br />

6/48 HMI RFID module<br />

6/50 MP 177 6" Touch portrait<br />

6/51 Front panel 15" Touch and Keys for<br />

Panel <strong>PC</strong>s, resistant to honing oil<br />

6/53 Flat Panels 6.4" and 10.4" for Panel <strong>PC</strong><br />

6/54 Food and beverage industry,<br />

pharmaceuticals<br />

6/56 Panels and Panel <strong>PC</strong>s<br />

with stainless steel front<br />

6/59 HMI Panels as rear-mounted devices<br />

6/61 Flat Panels with stainless steel front<br />

6/63 HMI stainless steel operator stations<br />

6/64 Oil & gas/chemicals/marine<br />

6/65 MP 377 15" Touch daylight readable<br />

6/67 TEK – Temperature Extension Kit


6<br />

Customized Automation<br />

Introduction<br />

Customized Automation<br />

■ Overview<br />

Turnkey Products<br />

Assembling, wiring, customer-specific image<br />

OEM Products<br />

Front Panel, enclosure, equipment<br />

Design Products<br />

Company logo, caption and colors<br />

Customized Automation – Hardware<br />

Customized Automation – overview<br />

With Customized Automation, field-proven SIMATIC,<br />

SIMATIC I<strong>PC</strong> and SIMATIC HMI standards are converted into<br />

individual products and systems – tailored precisely to the<br />

customer's requirements.<br />

6/2<br />

Customized<br />

Hardware<br />

• Turnkey Products<br />

OEM Products<br />

Design Products<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

SIMATIC Standard products<br />

• SIMATIC Controller SIMATIC HMI SIMATIC I<strong>PC</strong><br />

Customized Automation<br />

Customized<br />

Software<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Customized<br />

Service &<br />

Support<br />

SIMATIC Standard products<br />

SIMATIC Controller SIMATIC HMI SIMATIC I<strong>PC</strong><br />

Customized<br />

Logistics<br />

The portfolio covers the hardware and software range, but also<br />

support and logistics.<br />

G_<strong>ST</strong><strong>80</strong>_XX_00440<br />

G_<strong>ST</strong><strong>80</strong>_XX_00441


■ Benefits<br />

Time savings<br />

you can use comprehensive customization know-how and our<br />

long years of experience with the SIMATIC components<br />

you do not have to build up any additional know-how, and you<br />

can concentrate completely on your own core competence<br />

Increase in profitability<br />

you invest your money and resources selectively in your core<br />

competence<br />

you implement reliable material requirements and logistic<br />

planning, tailored to your needs, thanks to our logistic services<br />

you have maximum investment security thanks to maximum<br />

quality, long-term availability and continuity with SIMATIC,<br />

SIMATIC I<strong>PC</strong> and SIMATIC HMI<br />

you save unnecessary costs thanks to tailor-made solutions,<br />

and you benefit from the global service & support concepts<br />

with SIMATIC, SIMATIC <strong>PC</strong> and SIMATIC HMI<br />

Increase in competitive edge for the machine<br />

you use SIMATIC products that correspond to the highest<br />

quality standards, offer optimal performance, and thus boost<br />

your productivity by minimizing standstill times<br />

you receive customized products with Customized<br />

Automation that fit outstandingly well into the "Totally<br />

Integrated Automation" (TIA) concept<br />

you stand out not only for exceptional technology but also for<br />

individual design of your machine, for example, by printing a<br />

logo on the front of the enclosure.<br />

Customized hardware:<br />

Customized products are modified SIMATIC HMI standard<br />

products. According to the necessary degree of modification of<br />

the hardware, these types of product are separately identified<br />

as:<br />

Design products<br />

OEM products<br />

Turnkey products<br />

The customer-specific modifications are available in all performance<br />

classes, starting with Push Button Panels or Key Panels,<br />

Basic Panels, Comfort Panels up to Rack/Box/Panel <strong>PC</strong>s.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Customized Automation<br />

Introduction<br />

Customized Automation<br />

Customized software:<br />

In the case of customer-specific products, the software can also<br />

be individually installed. This includes the generation of<br />

operating systems and also the integration and installation of<br />

driver software and images – for complete, turnkey systems.<br />

Customized software products are<br />

Remote Operate Software<br />

for implementation of multi-user systems with HMI I<strong>PC</strong> and<br />

thin clients on the basis of MP 377 and HMI I<strong>PC</strong>477<br />

SIMATIC KNX/EIB2S7<br />

enables integration of actuators/sensors on a KNX/EIB bus of<br />

building automation systems into SIMATIC S7<br />

Customized products from various sectors<br />

SIMATIC HMI products are provided with additional features in<br />

order to facilitate optimum use in specific sectors of industry.<br />

Stainless steel front panels for the food, beverage and tobacco<br />

industry are one such example. With the exception of their front<br />

panels, the devices are identical to standard products in respect<br />

of function and technology.<br />

We can offer products for the following sectors:<br />

Renewable energy<br />

Automotive industry – HMI for factory automation<br />

General machine construction<br />

Food and beverage industry/pharmaceuticals<br />

Oil & gas/chemicals and shipbuilding<br />

Customized products for various industries are developed and<br />

produced in conjunction with a customized product agreement.<br />

■ More information<br />

More information is available in the Internet at<br />

www.siemens.com/hmi-oem<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6/3<br />

6


6<br />

Customized Automation<br />

Customized hardware<br />

Customized hardware<br />

■ Overview<br />

Customized products are modified SIMATIC HMI standard<br />

products<br />

A distinction is made according to the degree of hardware<br />

modification:<br />

Design products<br />

OEM products<br />

Turnkey products<br />

The Open Platform Program is available for customized software<br />

solutions.<br />

With these possible modifications, products are planned for<br />

special customer requirements in the various industries.<br />

Customized products from various sectors<br />

Further information can be found on the Internet at:<br />

www.siemens.com/hmi-oem<br />

Proportion of customized modifications on the individual<br />

product types:<br />

Standard<br />

Products<br />

Customized hardware:<br />

Design products<br />

Customized design means modifying the design and visual<br />

impact of the SIMATIC, SIMATIC HMI and SIMATIC I<strong>PC</strong> products<br />

for seamless adaptation into the customer's individual machine<br />

and plant design and special operator philosophy.<br />

The modification options are:<br />

Changing the company logo and device type designation<br />

Changing the keyboard color scheme, the key labeling, or the<br />

key symbols<br />

Changing the enclosure color (front frame)<br />

Design products are fully compatible with the standard products<br />

in technology and functionality, and can thus be fully integrated<br />

into the Totally Integrated Automation environment. Identical<br />

technology enables, for example, replacement using standard<br />

devices in the event of a fault in case the machine or plant<br />

supplier does not currently have a customized product in the<br />

spare parts warehouse.<br />

OEM products<br />

Product modifications for OEM (Original Equipment Manufacturer)<br />

customers are suitable for individual, industrial automation<br />

solutions that cannot be fulfilled with the help of standard<br />

products, or can only be handled with design-modified panels.<br />

6/4<br />

10% 15%<br />

Design<br />

Products<br />

OEM<br />

Products<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

25%<br />

Turnkey<br />

Products G_<strong>ST</strong><strong>80</strong>_XX_00296<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

OEM products are individual solutions based on<br />

SIMATIC standard components. They are specified, offered,<br />

developed and supplied individually in consultation with the<br />

customer.<br />

For this purpose, we simply combine the standard components,<br />

the customized components, and the additionally required<br />

software function expansions into a SIMATIC OEM device, as<br />

with a modular system.<br />

Modification options:<br />

Changes in the keyboard layout, key size/design and key<br />

arrangement<br />

Freely definable front dimensions and mechanical<br />

components<br />

Integration into enclosure for desktop use or support arm<br />

mounting<br />

Different processes and memory media<br />

Different display technologies, sizes and resolutions<br />

Distributed configuration<br />

Additional modules or interfaces<br />

Freely selectable Windows versions as operating systems,<br />

pre-installed SIMATIC software packages<br />

However, new OEM products can frequently be based on<br />

already implemented OEM products for efficiency and cost<br />

savings (see product examples). The end product is then<br />

represented as a customized modification of an existing<br />

OEM product.<br />

Our OEM devices are available in every performance class –<br />

starting from OEM Push Button Panels, through Text Displays,<br />

Touch and Operator Panels, right up to multifunctional platforms<br />

(MPs) and <strong>PC</strong>s in rack/box/panel versions with extensive<br />

changes to hardware, equipment and installed software.<br />

Customized OEM products are developed and produced in<br />

various stages in accordance with quality standards.<br />

Turnkey products<br />

Customized turnkey products are ready-to-install and ready-touse<br />

products from a single source that have been combined and<br />

assembled to customer specifications and in accordance with<br />

the specific technical requirements of HMI products. With the<br />

turnkey products, the HMI products are tested and supplied,<br />

e.g. as complete operator stations, that is, mounted and wired in<br />

special enclosures, and installed with the specified software:<br />

Optimized HMI operator station: ergonomic, functional,<br />

certified and tested<br />

Optimal mechanical installation of the devices with defined<br />

high degree of protection<br />

Flexible in installation and wiring<br />

Variable mounting options (support arm, stand,<br />

wall-mounting)<br />

Certified in accordance with VDE, CE and UL (in accordance<br />

with agreements and statutory conditions)<br />

Vibration-tested and shock-tested<br />

Packaged for safe transport<br />

Tested heat balance with passive cooling and with specified<br />

ambient temperature<br />

Customer-specific software suite with electronic software<br />

release management<br />

Customized SIMATIC turnkey products offer standard product<br />

quality from a single source and are ready-to-install and<br />

ready-to-use.


■ Overview<br />

For machines and systems, SIMATIC HMI products in individual<br />

corporate design are important for customers when making<br />

purchasing decisions. Seamless integration of the operator<br />

panels where operation and ergonomics are concerned as well<br />

as in the overall machine and system design is very important.<br />

The HMI devices with customer-specific design fully meet these<br />

requirements.<br />

With Digital Express Design, the following requirements can now<br />

also be fulfilled:<br />

Extremely fast design implementations<br />

Implementation of even low minimum quantities (no general<br />

agreements)<br />

Photo-realistic design up to 600 dpi<br />

Color gradients in the logo<br />

The following changes (design variants) are possible:<br />

Version A:<br />

Inserting the individual company logo instead of the <strong>Siemens</strong><br />

logo and changing the type designation<br />

Version B:<br />

Version A + changing keyboard colors, key labels, symbols<br />

and background color<br />

Version C:<br />

Version B + changing the frame color for the front frame<br />

Digital Express Design:<br />

Version B for small quantities with accelerated execution of the<br />

project<br />

The main requirements based on the customer's project for<br />

using the above design versions are as follows:<br />

Versions A-C:<br />

A contractually agreed minimum quantity p. a. is necessary<br />

Stockpiling in accordance with contract<br />

Any quantity is possible according to forecast<br />

First deliveries approximately 8 weeks after design start<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Customized Automation<br />

Customized hardware<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Design products<br />

Digital Express Design:<br />

Defined minimum order quantities without additional<br />

contractual agreement<br />

Delivery of the minimum order quantity 7 working days after<br />

released design draft<br />

Larger, unplanned quantities as partial deliveries, depending<br />

on availability<br />

First delivery approx. 2-3 weeks after receipt of order<br />

Available for SIMATIC HMI Touch devices<br />

The design products are exactly the same as the HMI standard<br />

products regarding technology and functionality, they only differ<br />

in the color and outward appearance. The same product basis<br />

enables the use of standard devices in case of a failure if the<br />

machine or plant supplier does not have a customized design<br />

product available in their own spare parts store at the time.<br />

The flexible production of the SIMATIC HMI Panels and<br />

Panel <strong>PC</strong>s enables economical manufacture of design products<br />

even with smaller ordering quantities. In this case, devices of<br />

customized design are manufactured in the series production<br />

factory, and are subject to the same quality requirements as<br />

standard devices.<br />

The creation of customized designs is handled by a professional<br />

industrial designer:<br />

Customer consulting and production of proposals and drafts<br />

Experience in the ergonomics of human-machine interfaces<br />

Knowledge in handling graphic and design tools, color tables<br />

and fonts<br />

Competence in the selection of appropriate fonts and<br />

standardized symbols for machine operation<br />

Short response times<br />

HMI Designer Services:<br />

Design and specification of the requested, customer-specific<br />

design versions A, B or C and Express Design in direct<br />

consultation with the customer<br />

Obtaining required customer approval<br />

Design draft and release of sample template<br />

Archiving<br />

HMI Designer response time:<br />

First draft 5 days after design start<br />

The predefined services of the Design Center are included in the<br />

project non-recurring costs (see "Additional information").<br />

A quotation will be made for any further changes and consultation<br />

services.<br />

Regarding customized design it is also possible to match the<br />

colors of various HMI design products in order to achieve a<br />

uniform corporate identity. The associated costs will be calculated<br />

according to actual requirements.<br />

6/5<br />

6


6<br />

Customized Automation<br />

Customized hardware<br />

Design products<br />

■ Benefits<br />

Seamless adaptation to system design and special operating<br />

philosophy of the customer<br />

No cutbacks on ergonomics compared to standard products<br />

The flexible production of the SIMATIC HMI Panels makes the<br />

manufacture of even small quantities of devices economically<br />

viable with customer-specific design based on standard<br />

products manufactured in the series plants.<br />

■ Ordering data<br />

According to size<br />

of display<br />

6/6<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

They can be replaced by standard devices and are<br />

completely compatible with the standard devices regarding:<br />

- Functions and interfaces<br />

- SIMATIC HMI configuration software<br />

- Housing and installation dimensions<br />

- Logistics and service, identified repairs<br />

- UL and CE certification, more upon request<br />

Device type MLFB of basic product Minimum p.a.<br />

order quantities<br />

for normal design<br />

Version A/B<br />

Touch<br />

4 " TP177 4" Touch 6AV6 642-0BD01-3AX0 100 -<br />

7 " HMI TP700 Comfort 6AV2 124-0GC01-0AX0 75 3<br />

MP177 6" 6AV6 642-0EA01-3AX0 75 3<br />

TP277 6" 6AV6 643-0AA01-1AX0 75 4<br />

TP177 6" DP mono 6AV6 642-0BC01-1AX1 100 4<br />

TP177 6" DP/PN color 6AV6 642-0BA01-1AX1 100 4<br />

9 " HMI TP900 Comfort 6AV2 124-0JC01-0AX0 75 3<br />

MP277 8" Touch 6AV6 643-0CB01-1AX1 75 3<br />

12 " HMI TP1200 Comfort 6AV2 124-0MC01-0AX0 50 3<br />

MP 377 12" Touch 6AV6 644-0AA01-2AX0 50 3<br />

MP 277 10" Touch 6AV6 643-0CD01-1AX1 50 3<br />

15 " MP 377 15" Touch 6AV6 644-0AB01-2AX0 50 3<br />

HMI TP1500 Basic color PN 6AV6647-0AG11-3AX0 50 3<br />

19 "<br />

Key<br />

MP 377 19" Touch 6AV6 644-0AC01-2AX1 50 3<br />

4 " HMI KTP400 Comfort 6AV2 124-2DC01-0AX0 100 -<br />

HMI KP400 Comfort 6AV2 124-1DC01-0AX0 100 -<br />

HMI KTP400 Basic mono PN 6AV6 647-0AA11-3AX0 200 -<br />

OP 77B 6AV6 641-0CA01-0AX1 200 -<br />

OP 77A 6AV6 641-0BA11-0AX1 200 -<br />

OP 73 6AV6 641-0AA11-0AX0 200 -<br />

OP 73micro 6AV6 640-0BA11-0AX0 200 -<br />

7 " HMI KP700 Comfort 6AV2 124-1GC01-0AX0 75 -<br />

HMI KTP600 Basic mono PN 6AV6 647-0AB11-3AX0 200 -<br />

HMI KTP600 Basic color DP 6AV6 647-0AC11-3AX0 200 -<br />

HMI KTP600 Basic color PN 6AV6 647-0AD11-3AX0 200 -<br />

OP277 6" 6AV6 643-0BA01-1AX0 75 -<br />

OP177B 6" DP mono 6AV6 642-0DC01-1AX1 100 -<br />

OP177B 6" DP/PN color 6AV6 642-0DA01-1AX1 100 -<br />

9 " HMI KP900 Comfort 6AV2 124-1JC01-0AX0 50 -<br />

MP277 8" Key 6AV6 643-0DB01-1AX1 75 -<br />

12 " HMI KP1200 Comfort 6AV2 124-1MC01-0AX0 50 -<br />

HMI KTP1000 Basic color DP 6AV6 647-0AE11-3AX0 75 -<br />

HMI KTP1000 Basic color PN 6AV6 647-0AF11-3AX0 75 -<br />

MP 377 12" Key 6AV6 644-0BA01-2AX1 50 -<br />

MP 277 10" Key 6AV6 643-0DD01-1AX1 50 -<br />

Minimum<br />

order quantities<br />

per order;<br />

express design


For all other products not listed here, please enquire.<br />

■ More information<br />

Ordering information<br />

Explanation of the tables with selection and ordering data:<br />

"Device type" and "Order No. of the associated standard device"<br />

"Type specification" and "Order No." of the HMI product to be<br />

modified.<br />

Start of delivery of a design version cannot commence less<br />

than 2 months after the start of delivery of a standard device.<br />

"Design version"<br />

Type of modification required, according to design versions<br />

"Minimum quantity"<br />

In order to be able to offer high-quality products at a<br />

competitive price in the global market, there must be a lower<br />

limit to the annual quantity and a minimum order quantity.<br />

A clear presentation of all possible design devices with the<br />

associated minimum quantities can be found in the overview<br />

tables.<br />

Prices and one-off costs<br />

An additional amount over the price of the standard device is<br />

charged for the customized design device.<br />

There are no additional costs for a one-off design (without<br />

Change Requests).<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Customized Automation<br />

Customized hardware<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Design products<br />

■ Ordering data<br />

According to size Device type Order No. Minimum<br />

of display<br />

Touch/Monitor/Key<br />

p.a. order quantities<br />

for normal design<br />

Version A/B<br />

12 " Flat Panel 12" Touch or Monitor depending on the configuration 30<br />

Panel <strong>PC</strong> 12" Touch or Key depending on the configuration 30<br />

15 " Flat Panel 15" Touch or Monitor depending on the configuration 30<br />

Flat Panel 15" Touch PRO 6AV7 861-5TB10-1BA0 30<br />

HMI I<strong>PC</strong>477C 15" Touch PRO depending on the configuration 30<br />

Panel <strong>PC</strong> 15" Touch or Key depending on the configuration 30<br />

19 " Flat Panel 19" Touch or Monitor depending on the configuration 30<br />

Flat Panel 19" Touch PRO 6AV7 861-6TB10-1BA0 30<br />

HMI I<strong>PC</strong>477C 19" Touch PRO depending on the configuration 30<br />

Panel <strong>PC</strong> 19" Touch depending on the configuration 30<br />

Processing<br />

A special order processing is required for the customized<br />

design. Various approval steps by the customers are to ensure<br />

that the end product fully meets their expectations. The order is<br />

processed via the Delivery Center Nuremberg (LZN). Orders<br />

and deliveries of 1 unit or more depending on the version or<br />

contract are possible!<br />

Repairs/spare parts storage<br />

Only identified repairs are carried out.<br />

The customer-specific spare parts required for this purpose<br />

(device front panels) are to be stored and made available by the<br />

customer on expiry of the warranty period or on termination of<br />

supply.<br />

Contacts<br />

Please contact your local/national <strong>Siemens</strong> HMI representative<br />

(visit our Internet site for more information).<br />

Further information can be found on the Internet at:<br />

www.siemens.com/hmi-oem<br />

6/7<br />

6


6<br />

Customized Automation<br />

OEM products<br />

OEM products<br />

■ Overview<br />

HMI product modifications for OEM customers are suitable for<br />

complex industrial automation tasks that cannot be<br />

implemented using standard products.<br />

OEM devices are available in all performance classes: from<br />

OEM Push Button Panels through Micro Panels, Panels and<br />

Multi Panels right up to Panel <strong>PC</strong>s as well as Rack and<br />

Box <strong>PC</strong>s – with far-reaching changes in hardware, equipment<br />

and software.<br />

The following modifications are possible:<br />

- Changes to keyboard layout: Number of keys, key size/<br />

design and key layout<br />

- Freely definable front dimensions and mechanical components<br />

- A variety of processors for customized performance<br />

- A variety of memory media and capacities<br />

- Installation of function cards<br />

- Display technologies, sizes and resolutions<br />

- Options such as direct key modules<br />

- Distributed configuration of Panel <strong>PC</strong>s<br />

- Housings for desktop, stand or support-arm versions<br />

(operator station concept)<br />

- Additional modules or interfaces, of course always complete<br />

with the necessary device drivers<br />

- Selectable Windows operating systems<br />

- Preinstalled SIMATIC software and customized software<br />

packages<br />

6/8<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

The SIMATIC HMI OEM concept represents "customizing at its<br />

best":<br />

Your requirements, based on sector and application knowhow,<br />

combined with our experience in the development of<br />

operator control and monitoring devices of all performance<br />

classes, result in tailor-made solutions at a fair price.<br />

Customized OEM products are developed in defined stages<br />

in accordance with quality standards and produced using<br />

standard plant facilities – always in close cooperation with the<br />

customer.<br />

Users in various industries, including regenerative energies,<br />

the automotive industry, the food, beverage and tobacco<br />

industries, the oil and gas industry, as well as in the<br />

plastics-processing industry and others are benefiting<br />

from our experience of delivering tried and tested OEM<br />

versions and industry standards.


■ Overview<br />

MP 377 15" Touch OEM according to flexible front-mounting<br />

concept for injection molding machines<br />

Customer requirements with regard to HMI devices are<br />

extremely diverse. The flexible front-mounting concept makes it<br />

possible to meet these diverse customer-specific requirements.<br />

The flexible front-mounting concept enables customized front<br />

design as well as customized layout of the operator elements.<br />

The SIMATIC products form the technical basis of a device<br />

developed according to the flexible front-mounting concept.<br />

The diversity of the standard products enables integration<br />

from the small 6" Flat Panel right up to high-performance<br />

<strong>PC</strong> technology. The customer's own, typical operator philosophy<br />

can also be optimally implemented since the flexible frontmounting<br />

concept offers the wide range of operator elements –<br />

from the classic 3SB operator elements, through short-stroke<br />

keys, right up to membrane keyboards.<br />

The flexible communication options with PROFIBUS or<br />

PROFINET facilitate integration into new or existing machine<br />

concepts. Fail-safe operation can be implemented by using<br />

PROFIsafe components. To meet individual customer requirements,<br />

a device built in accordance with the flexible frontmounting<br />

concept can be designed as a built-in device or as a<br />

stand-alone unit. If designed as a stand-alone unit, care is taken<br />

to make the enclosure slimline and modern in appearance.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Customized Automation<br />

OEM products<br />

Flexible front design concept for HMI products<br />

The flexible front-mounting concept allows customized<br />

HMI solutions based on the field-proven SIMATIC components.<br />

A project using the flexible front-mounting concept is the<br />

obvious choice especially for the following customer requirements:<br />

Customized integration of operator elements and display<br />

systems<br />

High integration density of SIMATIC products<br />

Demand for customized design and layout<br />

Demand for optimal integration into plants and machinery<br />

Compact design as stand-alone product in enclosure<br />

Compact design as built-in unit at the machine level<br />

Use of field-proven components and thus also optimized<br />

time-to-market<br />

These requirements can be implemented for the customer by<br />

means of a flexible front-mounting concept.<br />

The general conditions for a project using the flexible frontmounting<br />

concept are:<br />

Minimum unit quantity 100 p.a.<br />

Project agreement<br />

- With unit quantity start-up forecasting and annual unit<br />

quantities for the project<br />

- for funding development costs<br />

- Key project dates and standard start-of-delivery dates<br />

- Logistics with delivery times<br />

■ Application<br />

The industrial environment imposes diverse requirements on<br />

technology and design. Thanks to its variable and modular<br />

approach, the flexible front-mounting concept opens up diverse<br />

options for re-combining SIMATIC standard components in a<br />

compact device configuration with individualized design and<br />

layout. The possible uses are thus diverse and universal.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6/9<br />

6


6<br />

Customized Automation<br />

OEM products<br />

Flexible front design concept for HMI products<br />

■ Design<br />

■ More information<br />

The flexible design and the use of standard SIMATIC products Quotation preparation<br />

make it possible to meet just about every technical requirement<br />

with regard to customized HMI. Components that can be Product specification in accordance with customer require-<br />

combined to form an individualized HMI are listed below: ments Quotation preparation drafted by SIMATIC HMI<br />

specialists.<br />

Basic devices:<br />

Determining:<br />

Flat Panels with different screen diagonals<br />

One-time project costs<br />

Thin Client<br />

Costs for sample devices/prototypes<br />

Multi Panels<br />

Standard unit prices<br />

Panel <strong>PC</strong>s<br />

General conditions (product agreement)<br />

Operator control:<br />

There must be a minimum limit to the annual unit quantity/<br />

Touch functionality<br />

purchase quantity (minimum quantity per version: from 100) and<br />

Keys functionality with<br />

this must be agreed with the project customer. Customized<br />

- 3SB elements<br />

products can only be ordered in conjunction with a product<br />

- Short-stroke keys<br />

agreement. A customer-specific order number is allocated<br />

- Membrane keys (also illuminated)<br />

during the product agreement process.<br />

Key switches etc.<br />

Contacts<br />

Additional elements:<br />

Please contact the HMI representatives of your <strong>Siemens</strong> sales<br />

High-speed keys via PROFINET<br />

office/national company.<br />

Emergency stop (also PROFIsafe)<br />

Additional information on the Internet is available at:<br />

RFID module<br />

www.siemens.com/hmi-oem<br />

Front USB etc.<br />

Flexible front-mounting concept project development and<br />

Design:<br />

service<br />

Stand-alone (IP65 at front,


■ Overview<br />

Function cards are <strong>PC</strong> modules that perform customer-specific<br />

extended functions. They are installed at the manufacturer's<br />

plant as part of the <strong>PC</strong> production.<br />

This enables fully-tested, customized SIMATIC I<strong>PC</strong>s with<br />

function cards to be delivered quickly and easily.<br />

■ Benefits<br />

Expansion of the <strong>PC</strong> functionality tested within the system and<br />

ready to order:<br />

Time and cost savings due to a fast ordering process and<br />

commissioning<br />

Simplified, standardized ordering process for the complete<br />

I<strong>PC</strong> with function cards already inserted<br />

One contact for SIMATIC I<strong>PC</strong> and function cards, also for<br />

repair, service and support<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Application<br />

Customized Automation<br />

OEM products<br />

SIMATIC <strong>PC</strong> function cards<br />

For all applications in automation engineering in which the<br />

standard integrated interfaces of the existing industrial <strong>PC</strong> are<br />

not sufficient, e.g.:<br />

Measuring, open-loop and closed-loop control tasks<br />

Operating/visualization tasks<br />

Examples from the sectors are:<br />

Data collector and central interface in wind turbines as well as<br />

central monitoring in wind farms<br />

Diagnostic systems for end-of-line quality assurance in the<br />

automobile industry<br />

High-speed closed-loop control and open-loop control of chip<br />

handlers, as well as the control and visualization of CVD<br />

(Chemical Vapor Deposition) machines in the semiconductor<br />

industry<br />

Group control computers for machining centers and for<br />

connecting real mechatronic devices in the woodworking<br />

industry<br />

Order pickers for automated stores in pharmacies<br />

■ Function<br />

Expansion cards are available for the following functions:<br />

PROFIBUS / PROFINET<br />

Serial interfaces<br />

I/O bus systems<br />

Additional LAN interfaces<br />

Digital and analog I/Os<br />

Graphic expansions<br />

<strong>PC</strong>I 2xRS232<br />

2xRS485<br />

1 x LAN 10/100/100<br />

PROFIBUS DP<br />

PROFINET (4-port)<br />

<strong>PC</strong>Ie 4 RS 232 (x1)<br />

1 x LAN 10/100/1000 (x1)<br />

Dual Head graphic (x1)<br />

1) For the SIMATIC I<strong>PC</strong>847C, an optional graphic card is available via the<br />

standard configurator<br />

1)<br />

<strong>PC</strong>I104 2 x CAN<br />

2xRS485<br />

4xRS232<br />

Centralized <strong>PC</strong> IO peripherals:<br />

<strong>PC</strong> IO interface module for<br />

expanding with encoder/counter as<br />

well as <strong>PC</strong> IO digital modules and<br />

<strong>PC</strong> IO analog modules.<br />

In the maximum configuration this<br />

allows the integration of up to<br />

120 analog IO interfaces,<br />

320 digital IO interfaces, and<br />

12 encoder/counter interfaces.<br />

■ More information<br />

Contacts<br />

Please contact the HMI representative at your local <strong>Siemens</strong><br />

office/company.<br />

Further information can be found in the Internet under:<br />

http://support.automation.siemens.com/WW/view/en/32596843<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6/11<br />

6


6<br />

Customized Automation<br />

OEM products<br />

MP 270 data display<br />

■ Overview<br />

■ Benefits<br />

Extremely good readability<br />

Die-cast aluminum housing<br />

Rotatable and tiltable suspension unit<br />

Communication with control <strong>PC</strong> via Ethernet <strong>PC</strong>MCIA card<br />

Can be mounted on wall, desktop or support arm<br />

Customized Windows CE image<br />

Glass front for easy cleaning<br />

6/12<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

OEM version<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Application<br />

The OEM MP 270/data display handles only visualization<br />

functions. It is used for the visualization of coronary angiography<br />

systems in the medical field.<br />

■ Technical specifications<br />

Die-cast aluminum housing<br />

Customized application and customized WinCE image<br />

Display: 15"<br />

Resolution: 640 x 4<strong>80</strong> pixels (VGA)<br />

Degree of protection on front: IP65<br />

■ Ordering data Order No.<br />

OEM MP 270/data display Can only be ordered exclusively<br />

Order only in conjunction with a<br />

product agreement<br />

Status: Released for delivery<br />

Project runtime: None<br />

Non-recurring costs: None<br />

Minimum quantity: None<br />

■ More information<br />

Additional information is available on the Internet under:<br />

www.siemens.com/hmi-oem


■ Overview<br />

OEM MP 277 8.4" Touch<br />

■ Benefits<br />

Heavy-duty, die-cast aluminum housing<br />

Easy mounting on patient table with clamping device<br />

Low space requirements<br />

Extremely good readability<br />

Simple operation<br />

Joystick can be connected optionally on left or right<br />

Ethernet communication<br />

■ Application<br />

The OEM MP 277 8.4" Touch is suitable for use as a control<br />

console for coronary angiography systems in the medical field.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Customized Automation<br />

OEM products<br />

MP 277 8" Touch control console<br />

■ Technical specifications<br />

Rugged die-cast aluminum housing<br />

8.4" TFT display<br />

<strong>80</strong>0 x 600 pixel resolution<br />

Operation by means of touch screen and optional joystick<br />

Customized application and customized WinCE image<br />

Degree of protection on front: IP65.<br />

Option<br />

Different housing color<br />

■ Ordering data Order No.<br />

OEM MP 277 8.4" Touch On request<br />

Customized products can only be ordered in conjunction with a<br />

product agreement. The following points are defined in the<br />

product agreement:<br />

Status: Released for delivery<br />

Project runtime: None<br />

Non-recurring costs: None<br />

Minimum quantity: 200<br />

■ More information<br />

Additional information is available on the Internet under:<br />

www.siemens.com/hmi-oem<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6/13<br />

6


6<br />

Customized Automation<br />

OEM products<br />

MP 277 8" Touch portrait<br />

■ Overview<br />

MP 277 8" Touch portrait<br />

Use of the panels in portrait format is required wherever<br />

mounting space is limited. The MP 277 8" Touch in portrait format<br />

extends the range of standard panels in customized projects.<br />

6/14<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Vertical mount in case of limited space on machine<br />

Portrait format of screen contents<br />

Adapted Engineering System: "What you see is what you get".<br />

Proven functionality of the SIMATIC HMI standard products<br />

Together with WinAC MP 2007, it offers a compact<br />

combination of HMI and controller<br />

■ Application<br />

The MP 277 8" Touch portrait is designed both for vertical<br />

mounting with display in portrait format as well as for<br />

WinAC MP 2007 applications. The device is suitable for<br />

installation in machines where only limited space is available,<br />

e.g. packaging machines, automatic baking machines etc.<br />

■ Design<br />

MP 277 8" Touch with customized front and operator controls<br />

Decorative foil on the display for better sealing and display<br />

splinter protection<br />

The front is designed to be mounted in the cabinet from<br />

behind<br />

External dimensions and panel cutout customized according<br />

to customer specifications<br />

The remaining features of the device design correspond to<br />

those of the standard product on which it is based<br />

Angled adapter required for communication:<br />

- RS422/RS485 angled adapter


■ Technical specifications<br />

7.5" TFT color display<br />

4<strong>80</strong> x 640 pixel resolution<br />

The modified design of the display and the resolution should be<br />

taken into account when configuring the user interface.<br />

Special features:<br />

Type of installation:<br />

Rear mounting<br />

Degree of protection:<br />

IP65 (in combination with customer-specific enclosure and<br />

seal)<br />

Operator controls<br />

3 keys 24 V DC integrated, emergency stop<br />

Mounting dimensions:<br />

Enclosure OEM MP 277 T 8"<br />

External dimensions W x H x D<br />

(mm)<br />

233 x 322 x 66.5<br />

Installation cutout W x H (mm) 229 x 318<br />

Mounting depth (mm) min. 67<br />

1) The mounting depth increases relative to the thickness of the<br />

enclosure seal (compressed) provided by the customer.<br />

2) Depends on the installation technology and the enclosure seal used<br />

1)<br />

Degree of protection<br />

Front max. IP65 2)<br />

Rear IP20<br />

Weight (kg) Approx. 2.7<br />

The remaining technical specifications correspond to those of<br />

the associated standard device MP 277 8" Touch.<br />

Modification possibilities<br />

Customized design<br />

Resistant and rugged stainless steel front with finely ground<br />

surface for simple cleaning<br />

Customer-specific applications for Windows CE-based panels<br />

(Open Platform Program)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Customized Automation<br />

OEM products<br />

MP 277 8" Touch portrait<br />

■ Ordering data<br />

Product specifications and quotation preparations<br />

Product specification according to customer requirements<br />

Quotation preparation by SIMATIC HMI specialists,<br />

specification of:<br />

One-time project costs<br />

Costs for sample devices/prototypes<br />

Standard unit prices<br />

Product agreement with general conditions for the technology,<br />

quantity forecasts as well as logistics, service and repair<br />

agreements<br />

Processing<br />

Customized OEM products are developed and produced in<br />

various stages in accordance with quality standards. Prototypes<br />

are created to test products. Once the devices have been<br />

approved by the customer, they undergo certification and are<br />

introduced into the production process.<br />

Devices are produced in standard product factories, ensuring<br />

observation of customer quantity forecasts. For this purpose,<br />

individual quantity forecasts are exchanged with the customer.<br />

In the event of questions and problems, customers can contact<br />

our worldwide 24-hour SIMATIC Customer Support. This is<br />

complemented by a special OEM After Sales Support service,<br />

the Developer Service.<br />

Customized products can only be ordered in conjunction with a<br />

product agreement. The following points are defined in the<br />

product agreement:<br />

Delivery and pricing<br />

Logistics – annual volume, purchase quantity, delivery batch<br />

volumes<br />

Spare parts<br />

Service<br />

Repairs/spare parts storage<br />

Identified repairs are performed. Other repair concepts can be<br />

defined with the product agreement.<br />

The required customer-specific spare parts (device fronts) are to<br />

be stored and provided by the customer after expiration of<br />

warranty (upon delivery completion).<br />

■ More information<br />

Additional information is available on the Internet under:<br />

www.siemens.com/hmi-oem<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6/15<br />

6


6<br />

Customized Automation<br />

OEM products<br />

MP 277 6" Touch portrait<br />

■ Overview<br />

MP 277 6" Touch monochromatic portrait<br />

Use of the panels in portrait format is required wherever<br />

mounting space is limited. The MP 277 6" Touch monochromatic<br />

in portrait format extends the range of standard panels in<br />

customized projects.<br />

■ Benefits<br />

Vertical mount in case of limited space on machine<br />

Portrait format of screen contents<br />

Adapted Engineering System: "What you see is what you get".<br />

Proven functionality of the SIMATIC HMI standard products<br />

Together with WinAC MP 2007, it offers a compact<br />

combination of HMI and controller<br />

6/16<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Application<br />

The MP 277 6" Touch monochromatic portrait format is designed<br />

both for vertical mounting with display in portrait format as well<br />

as for WinAC MP 2007 applications. The device is suitable for<br />

installation in machines where only limited space is available,<br />

e.g. packaging machines, automatic baking machines etc.<br />

■ Design<br />

Special features:<br />

- 6" monochromatic vertical mounting,<br />

- Second RS485 interface (1 USB omitted) for<br />

customer-specific communication protocol<br />

The remaining features of the device design are comparable<br />

to those of the standard product on which it is based<br />

External dimensions and mounting cutout as for<br />

corresponding standard product<br />

Angled adapter required for communication:<br />

RS422/RS485 angled adapter<br />

■ Technical specifications<br />

5.7" monochromatic (blue mode) display<br />

240 x 320 pixel resolution<br />

The modified design of the display and the resolution should be<br />

taken into account when configuring the user interface.<br />

The remaining technical specifications correspond to those of<br />

the associated standard device MP 277 8" Touch.<br />

Modification possibilities<br />

Customized design<br />

Resistant and rugged stainless steel front with finely ground<br />

surface for simple cleaning<br />

Customer-specific applications for Windows CE-based panels<br />

(Open Platform Program)<br />

■ More information<br />

Additional information is available on the Internet under:<br />

www.siemens.com/hmi-oem


■ Overview<br />

Professional display system for continuous,<br />

maintenance-free operation<br />

The SIMATIC HMI Net Panel is multi-talented in large-scale<br />

display applications for industrial areas, because it is ideally<br />

suitable for factories and control consoles or for trade fairs and<br />

information points visited by the public.<br />

The Net Panel is based on a reliable industrial <strong>PC</strong> of the<br />

SIMATIC I<strong>PC</strong> series and is designed for 24-hour, maintenancefree<br />

operation in an industrial environment. It is extremely flexible<br />

in operation and can be used as a stand-alone solution or in the<br />

network as a complete industrial display system comprising<br />

several Net Panels. For applications that require audio output,<br />

versions of the Net Panel are available with audio modules and<br />

speaker equipment.<br />

Remote Control for setting up the SIMATIC HMI Net Panel<br />

The Remote Control Software included in the scope of delivery<br />

allows the Net Panel to be operated either locally or via the<br />

network. It enables the brightness and volume to be adjusted<br />

and the backlight to be switched off.<br />

For self-diagnosis the device temperature can be indicated. The<br />

Remote Control software allows the function to be shut down to<br />

prevent burn-in effects (anti-image sticking). The anti-image<br />

sticking function should, however, only be deactivated when<br />

adequate measures have been implemented on the Net Panel to<br />

prevent image sticking.<br />

Remote Operate as client/server solution for industrial<br />

display systems (optional)<br />

When Remote Operate is installed, four virtual graphics cards<br />

can be set up on one I<strong>PC</strong> and presented as extended desktops.<br />

On every SIMATIC HMI Net Panel, a Remote Operate client is<br />

installed that is assigned to a virtual graphic card. The different<br />

screen contents are distributed to the virtual graphic adapters<br />

using the HMI software WinCC. If the Net Panel is equipped with<br />

sound, MP3 and Wave files can be sent to a specific Net Panel<br />

where they can be played, using an easily accessible function.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Customized Automation<br />

OEM products<br />

SIMATIC HMI Net Panel<br />

High degree of system availability due to maintenance-free<br />

industrial design with IP65 degree of protection for continuous<br />

24-hour operation<br />

High security of investment due to rugged industrial products<br />

from SIMATIC that will remain available over the long term<br />

Reduced costs through low-wear and power-saving<br />

LED backlight and anti image sticking function<br />

Easy, cost-efficient integration in a standard network<br />

environment without VGA/DVI/HDMI extensions or expensive<br />

video signal extenders<br />

Optionally available with audio module and loudspeaker for<br />

sound output<br />

Flexible mounting on support arm systems, wall and ceiling,<br />

as well as back-to-back mounting and with an angle of<br />

inclination of up to 20° from the vertical<br />

Remote Control Software (locally on the device and remotely<br />

from the network) for the easy parameterization of<br />

-brightness<br />

- deactivation of backlighting<br />

- status messages of display<br />

- speaker control<br />

WinCC flexible 2008 SP2 support (I<strong>PC</strong>427C with<br />

1920 x 10<strong>80</strong> resolution)<br />

Optional:<br />

Remote Operate Software for presenting the contents of<br />

multiple screens on up to 4 Net Panels via a WinCC Server<br />

with sound support for the selective playing of Wave or<br />

MP3 formats on different Net Panels<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6/17<br />

6


6<br />

Customized Automation<br />

OEM products<br />

SIMATIC HMI Net Panel<br />

■ Application<br />

The SIMATIC HMI Net Panel is designed for demanding largescale<br />

displays in the industrial environment.<br />

It is based on rugged, reliable <strong>PC</strong> technology with interfaces for<br />

easy, cost-efficient integration in existing networks and offers<br />

maximum flexibility for positioning and mounting.<br />

The large LC display with LED backlight, continuous operation<br />

round-the-clock, and full <strong>PC</strong> openness makes the large-scale<br />

display ideal for use as an industrial manufacturing display, addon<br />

system, multimedia display, process visualization system,<br />

railway station and airport display (check-in, gate, baggage<br />

claim, advertising display) or at trade fairs, in shopping centers,<br />

hotels, museums and more.<br />

6/18<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Design<br />

The SIMATIC HMI Net Panel is a rugged display system with an<br />

integrated industrial <strong>PC</strong> and optional audio and loudspeaker<br />

equipment.<br />

LCD display with 1920 x 10<strong>80</strong> pixel full HD resolution<br />

Power saving and long-life LED backlight<br />

Integral SIMATIC industrial <strong>PC</strong><br />

Rugged and attractive device design with reduced enclosure<br />

depth<br />

Degree of protection IP65 all-round, industry compatible<br />

Solid, shatterproof front pane of 6 mm laminated glass<br />

Anti-glare front pane resistant to welding beads<br />

Safety eyebolts (removable as required) for additional<br />

protection against dropping in suspended installations<br />

Optional: adapter for Rose & Krieger FSK 50 support arm<br />

system<br />

Integrated wide-range power supply<br />

Rear connector for 1x USB (with IP65 protective cap),<br />

1x Industrial Ethernet (M12 4-pin with protective cap)<br />

Rear Quick-On connection for integrated 100 – 240 V power<br />

supply (connector included in scope of delivery)<br />

Rear status indicator<br />

■ Technical specifications<br />

SIMATIC HMI Net Panel SIMATIC HMI Net Panel<br />

Display<br />

Size 46" (116 cm) LCD TFT 46" (116 cm) LCD TFT<br />

Resolution 1920 x 10<strong>80</strong> Full HD (16:9) 1920 x 10<strong>80</strong> Full HD (16:9)<br />

Colors 16.7 million colors 16.7 million colors<br />

Reading angle +/- 178° +/- 178°<br />

Backlighting LED backlight LED backlight<br />

Brightness<br />

<strong>PC</strong> configuration<br />

Typically 400 cd/m² Typically 400 cd/m²<br />

Processor Celeron M 1.2 GHz Core2 Solo 1.2 GHz<br />

Main memory 1 GB 4 GB<br />

Mass storage Compact Flash 2 GB 250 GB hard disk<br />

Operating system<br />

General features<br />

Windows Embedded Standard 2009 Windows Embedded Standard 2009<br />

Enclosure design Industry-compatible steel enclosure, black, Industry-compatible steel enclosure, black,<br />

powder-coated<br />

powder-coated<br />

Glass front Shatterproof front pane of 6 mm laminated Shatterproof front pane of 6 mm laminated<br />

glass, anti-glare, resistant to welding beads glass, anti-glare, resistant to welding beads


■ Technical specifications (continued)<br />

Audio (optional)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Customized Automation<br />

OEM products<br />

Audio module 2x 15 W audio module 2x 15 W audio module<br />

Loudspeakers 1 pair, mounted to left and right,<br />

BOSE or alternatively Visaton<br />

Interfaces<br />

SIMATIC HMI Net Panel<br />

1 pair, mounted to left and right,<br />

BOSE or alternatively Visaton<br />

USB 2.0 1x at rear (with IP65 protective cap) 1x at rear (with IP65 protective cap)<br />

Ethernet 1x Industrial Ethernet, D-coded<br />

(M12 4-pin with protective cap)<br />

SIMATIC HMI Net Panel SIMATIC HMI Net Panel<br />

1x Industrial Ethernet, D-coded<br />

(M12 4-pin with protective cap)<br />

Power supply 100 – 230 V AC Quick-On plug connector 100 – 230 V AC Quick-On plug connector<br />

Keyboard; mouse Connectable via USB interface (optional<br />

USB hub recommended for commissioning)<br />

Ambient conditions<br />

Connectable via USB interface (optional<br />

USB hub recommended for commissioning)<br />

Degree of protection IP65 all-round; IP54 when USB is plugged in IP 65 all-round; IP54 when USB is plugged in<br />

Vibration load during operation 1g outline specification 1g outline specification<br />

Shock loading during operation 5g outline specification 5g outline specification<br />

Ambient temperature during operation<br />

Conformity<br />

5 … 45 °C 5 … 45 °C<br />

Approvals<br />

Dimensions<br />

CE CE<br />

External dimensions (W x H x D in mm), weight 1138 x 681 x 130, approx. 60 kg 1138 x 681 x 130, approx. 60 kg<br />

External dimensions (W x H x D in mm)<br />

with BOSE loudspeaker, weight<br />

1410 x 681 x 130, approx. 65 kg 1410 x 681 x 130, approx. 65 kg<br />

External dimensions (W x H x D in mm)<br />

with VISATON loudspeakers, weight<br />

Software<br />

1565 x 681 x 130, approx. 65 kg 1565 x 681 x 130, approx. 65 kg<br />

HMI software Supported by WinCC flexible 2008 SP2 Supported by WinCC flexible 2008 SP2<br />

or higher<br />

or higher<br />

Remote Control Software For adjustment and control, locally<br />

For adjustment and control, locally<br />

or via network<br />

or via network<br />

Remote Operate Server (optional) For the use of up to four Net Panels<br />

For the use of up to four Net Panels<br />

on one server<br />

on one server<br />

Remote Operate Client (optional) For the use of one Net Panel on one server For the use of one Net Panel on one server<br />

Special features<br />

with Remote Operate Server Software<br />

with Remote Operate Server Software<br />

Continuous glass front with<br />

Continuous glass front with<br />

narrow protective frame<br />

narrow protective frame<br />

Auto-refresh function for anti image sticking Auto-refresh function for anti image sticking<br />

2-point mounting, M8 on left and right sides 2-point mounting, M8 on left and right sides<br />

of enclosure, 75 mm spacing<br />

of enclosure, 75 mm spacing<br />

2x removable safety eyebolts on top<br />

2x removable safety eyebolts on top<br />

of enclosure<br />

of enclosure<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6/19<br />

6


6<br />

Customized Automation<br />

OEM products<br />

SIMATIC HMI Net Panel<br />

■ Ordering data Order No. ■ More information<br />

SIMATIC HMI Net Panel<br />

Customized modification options on request.<br />

Intelligent large-scale display;<br />

1920 x 10<strong>80</strong> full HD widescreen;<br />

Quotation preparation<br />

1 x Industrial Ethernet interface<br />

and 1 x USB on the rear; Windows<br />

Embedded Standard 2009;<br />

remote control software;<br />

SIMATIC HMI specialists define the product modifications<br />

precisely in accordance with customer requirements.<br />

This is followed by drafting of a quote with:<br />

enclosure design according to<br />

IP65, if plugged in at the rear<br />

IP54; includes Quick-On<br />

Non-recurring costs<br />

Prototype costs<br />

connector for 100 – 230 V<br />

power supply; CE<br />

Preferred type:<br />

46" screen diagonal,<br />

6AV7 426-0AA12-0BA0<br />

Standard unit prices<br />

and the marginal conditions in the form of a product<br />

agreement (e.g. minimum quantity).<br />

I<strong>PC</strong> Celeron M 1.2 GHz,<br />

1 GB RAM, 2 GB CF Card,<br />

without speakers,<br />

without audio module<br />

The defined device can then be ordered easily using this<br />

product agreement and a customized order number.<br />

46" screen diagonal,<br />

I<strong>PC</strong> Celeron M 1.2 GHz,<br />

1 GB RAM, 2 GB CF Card,<br />

with Visaton speakers,<br />

with audio module 2 x 15 W<br />

6AV7 426-0AA12-1BA0<br />

46" screen diagonal,<br />

I<strong>PC</strong> Celeron M 1.2 GHz,<br />

1 GB RAM, 2 GB CF Card,<br />

with BOSE speakers,<br />

with audio module 2 x 15 W<br />

6AV7 426-0AA12-2BA0<br />

46" screen diagonal,<br />

I<strong>PC</strong> Core2 Solo 1.2 GHz,<br />

4 GB RAM, 250 GB hard disk,<br />

without speakers,<br />

without audio module<br />

6AV7 426-0AD35-0BA0<br />

46" screen diagonal,<br />

I<strong>PC</strong> Core2 Solo 1.2 GHz,<br />

4 GB RAM, 250 GB hard disk,<br />

with Visaton speakers,<br />

with audio module 2 x 15 W<br />

6AV7 426-0AD35-1BA0<br />

Preferred type:<br />

46" screen diagonal,<br />

I<strong>PC</strong> Core2 Solo 1.2 GHz,<br />

4 GB RAM, 250 GB hard disk,<br />

with BOSE speakers,<br />

with audio module 2 x 15 W<br />

6AV7 426-0AD35-2BA0<br />

Accessories<br />

Adapter plate 6AV7 672-8GJ00-0AA0<br />

Two to four holes for<br />

SIMATIC HMI Net Panel,<br />

suitable for Rose & Krieger FSK<br />

50 flange, 4x M10, <strong>80</strong> mm hole<br />

spacing, incl. 2x adapter screws,<br />

black, powder-coated<br />

6/20<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Overview<br />

Front view with speakers<br />

Interface module and integrated Box <strong>PC</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Customized Automation<br />

OEM products<br />

Panel <strong>PC</strong> 677B with 46"<br />

The rugged design with large display is intended for industrial<br />

use and maintenance-free use. The Panel <strong>PC</strong> 677B with<br />

46" display is therefore outstandingly suitable for use wherever<br />

sophisticated information display is required in the areas of<br />

manufacturing industry, control desks, information displays in<br />

public areas, or trade fairs. The intelligent large display can be<br />

positioned for ease of viewing using a support arm system and<br />

operated easily by means of the Remote Control software<br />

included in the scope of supply.<br />

■ Application<br />

Automotive and manufacturing industry<br />

Pharmaceuticals industry<br />

Logistic sector<br />

Control desks<br />

Information displays<br />

■ Design<br />

Box <strong>PC</strong> 677B computing unit<br />

TFT LCD 46" with 4 mm laminated glass screen<br />

Industrial display for 24/7 continuous operation,<br />

MTBF 50,000 hrs<br />

Anti-glare coating<br />

Degree or protection IP65 on front/IP54 at rear<br />

Welding splatter-proof front<br />

Powder-coated sheet-steel enclosure<br />

Suitable for fixing to support system<br />

Audio amplifier module for up to 3 speaker pairs (optional)<br />

Remote Control software for operation<br />

WinCC flexible support<br />

Easily accessible interfaces on the enclosure<br />

Quiet operation in environments up to 40 °C<br />

without air-conditioning<br />

Quiet operation in environments up to 50 °C<br />

with air-conditioning (optional)<br />

<strong>PC</strong> without hard disk and without CD for maintenance-free use<br />

Auto-refresh function for protecting the display against the<br />

effects of burn-in<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6/21<br />

6


6<br />

Customized Automation<br />

OEM products<br />

Panel <strong>PC</strong> 677B with 46"<br />

■ Technical specifications ■ Ordering data Order No.<br />

Panel <strong>PC</strong> 677B<br />

with 46" TFT LCD<br />

<strong>PC</strong> configuration Celeron M440 processor,<br />

1.8 GHz.<br />

512 MB RAM<br />

CF drive 2 GB<br />

Windows XP embedded (SP2)<br />

operating system, English<br />

Display LCD TFT 46", 1366x768<br />

Reading angle +/-178°<br />

CCFT, MTBF 50,000 hours<br />

24/7 continuous operation<br />

Brightness Factory setting 300 cd<br />

Setting range 150 cd to 400 cd<br />

Speaker (optional) 1 pair mounted left and right;<br />

high-pressure speakers – 7 W<br />

additionally on the interface<br />

module 4 additional connections<br />

for 2 pairs of speakers, 7 W each<br />

Power supply 230 V AC<br />

Degree of protection IP65 on front<br />

IP54 at rear<br />

Protection class Protection class I in accordance<br />

with IEC 61140<br />

Permissible ambient temperature<br />

(without condensation)<br />

6/22<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Tested according to<br />

IEC 60068-2-2<br />

+5 °C to + 40 °C*<br />

(passive cooling)<br />

+5 °C to + 50 °C (active cooling)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Panel <strong>PC</strong> 677B with 46" display<br />

Box <strong>PC</strong> 677B<br />

installed in an enclosure<br />

together with a<br />

46" TFT LCD (1366 x 768),<br />

Celeron M440, 1.86 GHz,<br />

512 MB RAM, CF drive<br />

2 GB, Windows XP embedded,<br />

without audio amplifier,<br />

without speakers,<br />

without air conditioner<br />

E 6AV7 466-0AC00-0AA0<br />

with audio amplifier,<br />

with speakers,<br />

without air conditioner<br />

E 6AV7 466-0AC20-0AA0<br />

without audio amplifier,<br />

without speakers,<br />

with air conditioner<br />

E 6AV7 466-0AC01-0AA0<br />

with audio amplifier,<br />

with speakers,<br />

with air conditioner<br />

E 6AV7 466-0AC21-0AA0<br />

Delivery time 4 weeks ex works<br />

Minimum quantity 1<br />

CA product agreement for<br />

delivery logistics<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

Vibration, vibration in operation 0.25 g (30 – 300 Hz)<br />

■ More information<br />

Customer-specific modifications:<br />

Choice of enclosure color<br />

Shock resistance in operation 2.5 g<br />

Configurable computing units<br />

Approvals<br />

Interfaces<br />

CE<br />

3 x USB V2.0 (high current)<br />

M12 for 10/100/1000 Mbit/s<br />

Audio output 4 x 7 W into 8 Ohms<br />

Contacts<br />

Please contact the HMI representatives of your <strong>Siemens</strong> sales<br />

office/national company.<br />

(maximum cable length<br />

30 meters)<br />

Additional information on the Internet is available under:<br />

External dimensions (W x H x D)<br />

www.siemens.com/hmi-oem<br />

Basic cabinet<br />

Approx. 720 x 11<strong>80</strong> x 233 mm<br />

with loudspeakers<br />

Approx. 720 x 1465 x 233 mm<br />

Weight Approx. 92 kg<br />

Special features <strong>PC</strong> without hard disk and without<br />

CD for maintenance-free use<br />

RemoteControl software (also<br />

web-based) for volume control,<br />

brightness control, switching off<br />

backlight, transfer of status<br />

messages<br />

Auto-refresh function for display<br />

WinCC flexible 2008 support<br />

Support for up to four<br />

<strong>PC</strong>677B 46" units with different<br />

screen contents and sounds<br />

via SIMATIC I<strong>PC</strong> Server<br />

with WinCC V7.0


■ Overview<br />

Turnkey products are ready-to-install and ready-to-use<br />

SIMATIC HMI products.<br />

The benefits are found in the optimal mechanical installation of<br />

the devices, ergonomic, functional and with tested heat balance,<br />

and flexible in installation.<br />

HMI operator stations<br />

HMI devices with display diagonal of 10" and more are installed<br />

in selected enclosures to suit the function.<br />

HMI operator stations can be used wherever it is not possible to<br />

install human machine interface devices in a control cabinet or<br />

direct at the machine, and where off-the-shelf, turnkey products<br />

can save on engineering overhead.<br />

Installation of a customized image in the devices is possible<br />

(ready-to-run). Customized SIMATIC turnkey products offer<br />

standardized quality from a single source.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Customized Automation<br />

Turnkey products<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Turnkey products<br />

Backplane cover<br />

The backplane cover enables the enclosure of flat HMI products<br />

such as the HMI I<strong>PC</strong>477C or MP 377.<br />

The backplane cover is provided with a VESA flange on the rear.<br />

More operator elements can be installed on the side in additional<br />

enclosures.<br />

6/23<br />

6


6<br />

Customized Automation<br />

Turnkey products<br />

HMI operator stations<br />

■ Overview<br />

Turnkey products are SIMATIC HMI products or "ready-to-run"<br />

operator stations, i.e. pre-configured, ready for installation and<br />

ready-to-run SIMATIC Panels Thin Client, Multi Panels or Flat<br />

Panels and Panel <strong>PC</strong>s, installed in customer-specific enclosures.<br />

Examples are Multi Panels fitted in customized die-cast<br />

aluminum enclosures with external keyboard; with installed<br />

application software, ready for connection, and ready-to-run.<br />

Application example: Multi Panel in aluminum enclosure with operator<br />

controls, two-tier and with external keyboard<br />

6/24<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

High industrial capability thanks to an all-round rugged, tried<br />

and tested design:<br />

Ergonomic, technically proven and certified solutions ready<br />

for operation<br />

Safe operation even under difficult ambient conditions<br />

Temperature-tested and temperature-monitored<br />

Suitable even for special industries, e.g. stainless steel<br />

versions for the food, beverage and tobacco industries<br />

For high availability and a safe return on your investment<br />

<strong>Siemens</strong> quality support, service and repair<br />

The following issues are considered when developing the<br />

HMI operator stations:<br />

Optimal HMI product installation technology to eliminate<br />

thermal hotspots and heat pockets in the housing<br />

Calculation of actual maximum permissible ambient<br />

temperature of the entire operator station in continuous duty at<br />

location of use. Data takes into account device heat<br />

dissipation values<br />

Ensuring the adherence to the load limits for rotary mass<br />

storage systems and large displays verified by shock and<br />

vibration tests on the entire operator station during operation<br />

Adherence to legal regulations (certifications)<br />

Determination and testing of required degrees of protection<br />

and EMC measures<br />

Assurance of surface quality along with its abrasion and<br />

chemical resistance<br />

To the greatest possible extent, passive technology provides<br />

the basis for all measures to improve the suitability of use of<br />

the operator stations in specific environments (e.g. no active<br />

air conditioning). The aim is to ensure durability and fault-free<br />

operation with minimum maintenance.<br />

■ Application<br />

Complete HMI operator stations can be used wherever operator<br />

control and monitoring devices cannot be installed in a control<br />

cabinet or directly at the machine. Operator stations are suitable<br />

for:<br />

Industrial application<br />

Near-industrial application<br />

Use in secondary applications in food, beverage and tobacco<br />

production<br />

Stainless steel version in the primary areas of the food,<br />

beverage and tobacco industries<br />

HMI turnkey products can be used wherever prefabricated,<br />

ready-to-run hardware and software products can be used to<br />

save engineering.


■ Design<br />

The HMI operator station concept is based on a modular system<br />

where HMI devices are built into selected enclosures to suit the<br />

functionality.<br />

HMI device enclosure for all-round protection (IP65)<br />

Mounting possible on stand or supporting arm<br />

Rotation possible by means of adjusting elements<br />

Connection option for external keyboard and mouse<br />

Installation option for specific hardware components<br />

Ambient temperature for turnkey products<br />

The ambient temperature is always lower than the max. permissible<br />

ambient temperature of the HMI products (temperature<br />

values in Manual) installed in the operator station housing.<br />

Depending on the components and version (which means<br />

according to heat dissipation), permissible ambient temperatures<br />

around the operator station will vary between 5 °C and<br />

40 °C. Higher operator station ambient temperatures can be<br />

achieved by applying additional cooling measures.<br />

■ Function<br />

Fatigue-free, fast operation<br />

Operator station can be quickly adapted to different operators<br />

Coherent, easy-to-learn operator philosophy<br />

Rugged against shocks and vibrations in operation<br />

Suitable device selection (SIMATIC HMI devices from<br />

10" display)<br />

Ensuring the data transfer and access to drives and interfaces<br />

Direct operation of the machine (conventional operator<br />

elements for direct connection to machine units)<br />

Simple alphanumeric input<br />

Cleaning agents taken into account<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Customized Automation<br />

Turnkey products<br />

HMI operator stations<br />

■ Ordering data<br />

Ordering notes<br />

Product specifications and quotation preparations<br />

Product specification according to customer requirements<br />

Quotation preparation by SIMATIC HMI specialists,<br />

specification of:<br />

- one-time project costs<br />

- costs for sample devices/prototypes<br />

- standard unit prices<br />

- general conditions (product agreement)<br />

Processing<br />

Customized turnkey products are developed and produced in<br />

various stages in accordance with quality standards. Prototypes<br />

are created to test products. Once the devices have been<br />

approved by the customer, they undergo certification and are<br />

introduced into the production process.<br />

Devices are produced using standard plant facilities, ensuring<br />

observation of customer quantity forecasts. For this purpose,<br />

individual quantity forecasts are exchanged with the customer.<br />

In the event of questions and problems, customers can contact<br />

our worldwide 24-hour SIMATIC Customer Support. This is<br />

complemented by a special OEM After Sales Support service.<br />

Customer-specific project hotlines can be set up for bulk<br />

quantity customers.<br />

Customized products can only be ordered in conjunction with a<br />

product agreement. The following points are defined in the<br />

product agreement:<br />

Delivery and pricing<br />

Logistics – annual volume, purchase quantity, delivery batch<br />

volumes<br />

Spare parts<br />

Service<br />

Repairs/spare parts storage<br />

Only identified repairs are performed. The required customerspecific<br />

spare parts (device fronts) are to be stored and<br />

provided by the customer upon delivery completion.<br />

■ More information<br />

Contacts<br />

Please contact the HMI representatives of your <strong>Siemens</strong> sales<br />

office/national company.<br />

www.siemens.com/hmi-oem<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6/25<br />

6


6<br />

Customized Automation<br />

Turnkey products<br />

Rear panel cover<br />

■ Overview<br />

Flat Panel with backplane cover and additional enclosure, front view<br />

Panel <strong>PC</strong> 477B 15" with backplane cover, front view<br />

Current HMI products (Panels, Panel <strong>PC</strong>s and Flat Panels) have<br />

been designed in such a way that they can be installed in a<br />

control cabinet or a machine. For this purpose, the control<br />

cabinet or the machine is provided with an installation cutout into<br />

which the HMI product can be inserted from the front.<br />

However, developers are increasingly moving towards installing<br />

HMI products as operator units at the machine instead of in the<br />

machine. For this reason, <strong>Siemens</strong> has implemented the<br />

concept of the universal backplane cover for flat HMI products<br />

for the purpose of subsequently equipping HMI products such<br />

as Flat Panels or HMI I<strong>PC</strong>477C with a stable backplane of diecast<br />

aluminum or magnesium and a VESA-100 connection for a<br />

support arm or stand.<br />

All cables can be run direct through the cover and the support<br />

arm/stand. This underlines the mature impression of the overall<br />

system.<br />

6/26<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Flat Panel with backplane cover and additional enclosure, rear view<br />

Panel <strong>PC</strong> 477B 15" with backplane cover, rear view


Backplane cover<br />

MP 377 19"/<br />

Flat Panel<br />

19" Touch/Monitor<br />

Customized Automation<br />

Turnkey products<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Rear panel cover<br />

■ Benefits<br />

■ Ordering data Order No.<br />

The concept of the universal backplane cover is intended for flat Backplane cover 15" A 6AV7 672-4GD00-0AA0<br />

HMI products such as Panel <strong>PC</strong> 477 12" Key, Panel <strong>PC</strong> 477<br />

15" Touch, or MP 377 19"/Flat Panel 19" Touch/Display<br />

With VESA 100 on the rear for mounting on support system<br />

Additive enclosure to the right and/or left<br />

Backplane cover for 15" devices<br />

Backplane cover 19"<br />

Backplane cover for 19" devices<br />

A 6AV7 672-6GD00-0AA0<br />

With operator controls, built into the additive enclosure<br />

Additive enclosure suitable for all backplane covers<br />

With stainless steel keyboard mounted on backplane cover<br />

With removable panel for easier access to cables<br />

Backplane cover 19"<br />

with add-on enclosure<br />

Backplane cover for 19" devices<br />

Backplane cover 19"<br />

with 2 add-on enclosures<br />

A<br />

A<br />

6AV7 672-6GD01-0AA0<br />

6AV7 672-6GD11-0AA0<br />

The external dimensions (H x W) of the HMI products remain<br />

unchanged<br />

Backplane cover for 19" devices<br />

Backplane cover<br />

A 6AV7 672-4GD00-0AA0<br />

■ Application<br />

General machine construction<br />

for 15" devices<br />

Delivery time<br />

Minimum quantity 1<br />

■ Design<br />

CA product agreement<br />

VESA-100 connection on the rear.<br />

Mounting<br />

- On the support arm<br />

- On the supporting foot (desktop or floor)<br />

- Direct at the machine (for series mechanical equipment<br />

Repairs and spare parts<br />

Backplane cover<br />

A 6AV7 672-6GD00-0AA0<br />

for 19" devices<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

manufacturers)<br />

Cables can also be run direct through the VESA connection<br />

and the support arm/stand<br />

Flat visual aspect of the backplane cover; industrial character<br />

underlined<br />

Within the scope of customized projects:<br />

Mounting of enclosures for holding additional operator<br />

elements such as:<br />

- Pushbuttons<br />

- Switches<br />

-Lamps<br />

- Emergency-stop facilities<br />

-RFID modules<br />

■ Technical specifications<br />

Backplane covers in die-cast aluminum<br />

■ More information<br />

Height Dimensions Weight of<br />

modules (W x H x D) backplane<br />

in mm<br />

cover<br />

(in kg)<br />

Backplane cover<br />

Panel <strong>PC</strong> 477B<br />

15" Touch/12" Key<br />

7 HM 483 x 310 x 122 Approx. 5.5<br />

9 HM 483 x 400 x<br />

approx. 120<br />

Approx. 2.5<br />

Additive enclosure<br />

suitable for all cover<br />

models<br />

90 x 309 x 89 Approx. 1.0<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Customized modification options<br />

With VESA 100 on the rear for mounting on support systems<br />

Add-on enclosure left and/or right, suitable for all backplane<br />

covers<br />

Additional operator controls, built into the add-on enclosure<br />

Stainless steel keyboard secured on the backplane cover<br />

For larger projects starting from at least 50 units p. a., <strong>Siemens</strong><br />

offers customized versions of the backplane covers with add-on<br />

enclosures, integrated operator elements and an IP65 stainless<br />

steel keyboard. These backplane systems integrated into<br />

projects can also be ordered individually.<br />

Quotation preparation<br />

SIMATIC HMI specialists define the product modifications<br />

precisely in accordance with customer requirements.<br />

This is followed by drafting of a quote with:<br />

Non-recurring costs<br />

Prototype costs<br />

Standard unit prices<br />

and the marginal conditions in the form of a product<br />

agreement (e.g. minimum quantity).<br />

The defined device can then be easily ordered using this<br />

product agreement and a customized order number. You can<br />

find further information and examples at:<br />

www.siemens.com/hmi-oem<br />

6/27<br />

6


6<br />

Customized Automation<br />

Customized software<br />

Customized software<br />

■ Overview<br />

Customized software<br />

In the case of customer-specific products, the software can also<br />

be individually installed. This includes the generation of<br />

operating systems and also the integration and installation of<br />

driver software and images – for complete, turnkey systems.<br />

The customized software suite comprises:<br />

Generation of operating systems<br />

- for Windows XP embedded, for example and the RMOS3<br />

real-time operating system from <strong>Siemens</strong><br />

- for customized LINUX installation<br />

Integration and installation of driver software and pre-installed<br />

images<br />

- for additional cards, controllers, or memory media,<br />

for example<br />

- for completely turnkey systems<br />

In addition, customized software products based on our<br />

experience in the industrial automation offer an opportunity to<br />

set up multi-user systems and industrial remote operation and<br />

the possibility of integrating SIMATIC S7 into building<br />

automation:<br />

6/28<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Remote Operate Software<br />

The HMI Remote Operate Software is an industrial remote<br />

control system based on Ethernet.<br />

The software (server) enables the creation of a multi-user system<br />

with HMI I<strong>PC</strong>. As many as 6 operator stations (slaves) based on<br />

Thin Clients with MP 377 and HMI I<strong>PC</strong>477, with an identical<br />

image to the server, can be assigned to several servers at the<br />

same time.<br />

KNX/EIB2S7<br />

Bus systems for building management systems, such as<br />

KNX/EIB, and a host of associated components, are used for<br />

automation of building systems.<br />

While controllers for the room level are used for local automation,<br />

field-proven industrial components like SIMATIC are resorted to<br />

in the case of more complex, higher-level automation.<br />

Communication between the automation levels takes place over<br />

Ethernet using special KNXnet/IP interfaces. The KNX/EIB2S7<br />

software package provides blocks for communication between<br />

SIMATIC S7 and building automation components. This means<br />

message frames of the KNX bus can be processed in a<br />

SIMATIC controller.


■ Application<br />

Remote Operate Software<br />

<br />

Panel <strong>PC</strong> with connectedThin Clients<br />

<br />

<br />

<br />

<br />

Multi-user system with Panel <strong>PC</strong>s for up to 6 operator stations<br />

based on Thin Clients<br />

Including operator lock<br />

In one software application with identical image contents<br />

Identical screen resolution<br />

Excluding server operating system<br />

Industrial remote control<br />

- Independent of the installed software<br />

Identical images on all devices<br />

Automatic scaling takes place in the case of differences in<br />

screen resolution between server and client<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Remote Operate Clients<br />

<br />

Remote Operate Server<br />

Customized Automation<br />

Customized software<br />

<br />

<br />

<br />

Remote Operate Software<br />

Resolution up to 12<strong>80</strong> x 1024 with true color<br />

Remote Operate Server with Windows XP Professional or<br />

Windows XP embedded<br />

Up to 6 clients on one server<br />

Communication via Ethernet<br />

Designed for industrial requirements<br />

- Automatic login<br />

- Simple administration<br />

- Automatic reconnect<br />

- Permanent server/client assignment<br />

- Administration of operator authorization<br />

- Can be used after Windows login<br />

- Optional key-operated switch for operator authorization<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

<br />

6/29<br />

6


6<br />

Customized Automation<br />

Customized software<br />

SIMATIC KNX/EIB2S7<br />

■ Overview<br />

Software for communication between SIMATIC S7 and<br />

components of a building automation system<br />

For using components from industrial automation in the area<br />

of building automation<br />

Enables the integration of actuators/sensors into a<br />

KNX/EIB bus in automation solutions with SIMATIC S7<br />

For transferring information from the building automation<br />

system for automating a production plant<br />

■ Benefits<br />

Use of field-proven industrial components in the area of<br />

building automation<br />

Use of information from building automation for automating<br />

production plants<br />

Simple transfer of configuring data from the<br />

KNX configuring tool ETS3<br />

Automatic matching of KNX addresses with the associated<br />

SIMATIC addresses<br />

Use of the SIMATIC standard<br />

■ Application<br />

With rising energy awareness and increased requirements<br />

regarding user-friendliness and security, recent years have seen<br />

building automation facing far-reaching demands.<br />

Bus systems for building management systems, such as KNX/<br />

EIB, and a host of available components for these are used for<br />

implementing the corresponding systems.<br />

While controllers for the room level are used for local automation,<br />

field-proven industrial components like SIMATIC are resorted to<br />

in the case of more complex, higher-level automation.<br />

Communication between the automation levels takes place over<br />

Ethernet using special KNXnet/IP interfaces.<br />

The KNX/EIB2S7 software package provides blocks for communication<br />

between SIMATIC S7 and building automation components.<br />

This means message frames of the KNX bus can be<br />

processed in a SIMATIC controller.<br />

6/30<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Design<br />

The SIMATIC S7 is connected with the KNX/EIB components via<br />

KNXnet/IP interfaces. The interfaces connect the KNX/EIB bus<br />

with the Industrial Ethernet bus of the SIMATIC S7.<br />

Up to 5 KNXnet/IP interfaces can be connected to a SIMATIC S7<br />

controller. Up to 7,000 group addresses can be monitored,<br />

operated and read via these interfaces. The maximum number<br />

of group addresses depends on the controller type and the<br />

number of connected KNXnet/IP interfaces.<br />

KNX/EIB2S7 supports the following CPUs of the SIMATIC S7:<br />

ET 200<br />

- IM 151-8 PN/DP CPU<br />

S7 300/400<br />

- CPU 315-2 PN/DP<br />

- CPU 317-2 PN/DP<br />

- CPU 319-3 PN/DP<br />

- CPU 414-3 PN/DP<br />

- CPU 416-3 PN/DP<br />

Soft PLC<br />

- SIMATIC WinAC RTX 2008 SP 1<br />

SIMATIC S7-300 with CP 343-1<br />

- CPU 315-2 DP<br />

- CPU 317-2 DP<br />

- CPU 319-3 PN/DP<br />

SIMATIC S7-400 with CP 443–1 Advanced<br />

- CPU 412-2 MPI/DP<br />

- CPU 414-2 MPI/DP<br />

- CPU 416-2 MPI<br />

Supported KNXnet/IP interfaces:<br />

- N 146/2 IP router<br />

- N 148/221 IP interface<br />

- N 350E IP controller<br />

- N 151 IP viewer<br />

■ Mode of operation<br />

The KNX components are parameterized with the ETS 3 software<br />

of the Konnex organization.<br />

The KNX/EIB2S7 Editor is based on the exported parameterization<br />

data of ETS3 and evaluates the group address, data type,<br />

name and description. It only remains to select the group<br />

addresses that are to be received and to mark those that are to<br />

be automatically read at initialization.<br />

Addresses are assigned automatically by the editor. The<br />

addresses can be viewed in the Editor or exported for<br />

documentation.<br />

The parameterization of the blocks necessary for SIMATIC<br />

is generated by the Editor at the click of a mouse and can<br />

then be downloaded to SIMATIC. The blocks contained in<br />

KNX/EIB2S7 handle the communication on the basis of this<br />

parameterization.<br />

When data is received, the current values are saved in the data<br />

blocks provided for them. The values that have been updated<br />

are then marked. Equally, there are blocks available for the<br />

selective reading and writing of values.


■ Technical specifications<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Customized Automation<br />

Customized software<br />

SIMATIC KNX/EIB2S7<br />

Representation of the data types<br />

Data type KNX value EIS type SIMATIC data Representation in the User conversion<br />

type<br />

SIMATIC<br />

DPT1 BOOL EIS1 Bit TRUE/FALSE n<br />

DPT2 1 bit controlled EIS8 Byte MSB ([0000 00XY) LSB<br />

X = controlled<br />

Y = Value<br />

n<br />

DPT3 4 bits EIS2 Byte MSB (0000 XYYY) LSB<br />

X = Increase/decrease<br />

Y = Step 0-7<br />

n<br />

DPT4 Char EIS13 Char ASCII n<br />

DPT5 1 byte unsigned EIS14 Byte n<br />

DPT6 1 byte signed EIS14 Byte y<br />

DPT7 2 bytes unsigned EIS10 Word n<br />

DPT8 2 bytes signed EIS10 Int Representation in 2s<br />

complement<br />

n<br />

DPT9 2 bytes float EIS5 Real Conversion implicit in the<br />

driver<br />

n<br />

DPT10 Time of Day EIS3 DWord MSB (0000 0000/dddh<br />

hhhh/00mm mmmm/<br />

00ss ssss) LSB<br />

d = day 0 no day; 1-7<br />

h = hour 0-23<br />

m = minute 0-59<br />

s = second 0-59<br />

Important! No value check<br />

by the driver<br />

n<br />

DPT11 Date EIS4 DWord MSB (0000 0000/000d<br />

dddd/0000 mmmm/<br />

0yyy yyyy) LSB<br />

d = day 0-31<br />

m = month 0-12<br />

y = year 0-99 (0-89 = 2000-<br />

2089; 90-99 = 1990-1999)<br />

Important! No value check<br />

by the driver<br />

n<br />

DPT12 4 bytes unsigned EIS11 DWord n<br />

DPT13 4 bytes signed EIS11 D Int Representation in 2s<br />

complement<br />

n<br />

DPT14 Float EIS9 Real IEEE754 n<br />

DPT15 Access EIS12 DWord MSB (XXXX6 XXXX5/XXXX4<br />

XXXX3/XXXX2 XXXX1/EPDC<br />

NNNN) LSB<br />

X = AccessCode 6-digit;<br />

0-9; 1 nibble each<br />

E = 1 detection error<br />

(reading of access information<br />

code was not<br />

successful)<br />

P = Permission 0=not<br />

accepted; 1= accepted<br />

D = Direction 0=left to<br />

n<br />

DPT16 String EIS15 String (14) Driver evaluates header of<br />

the S7 string and then<br />

generates the 14-character<br />

long EIB string.<br />

n<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6/31<br />

6


6<br />

Customized Automation<br />

Customized software<br />

SIMATIC KNX/EIB2S7<br />

■ Ordering data Order No.<br />

KNX/EIB2S7 program package<br />

Task:<br />

Software for connecting KNX/EIB<br />

components from building<br />

management systems to<br />

SIMATIC S7<br />

Type of delivery:<br />

Editor, function blocks for<br />

SIMATIC S7, samples,<br />

documentation on CD<br />

License for Editor on USB flash<br />

drive<br />

B 6AV6 643-7AC10-0AA1<br />

B: Subject to export regulations: AL: N and ECCN: EAR99S<br />

6/32<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Overview<br />

SIMATIC HMI products are provided with additional features in<br />

order to facilitate optimum use in specific sectors of industry.<br />

Stainless steel front panels for the food, beverage and tobacco<br />

industry are one such example. With the exception of their front<br />

panels, the devices are identical to standard products in respect<br />

of function and technology.<br />

We can offer products for the following sectors:<br />

Renewable energy<br />

Automotive industry – HMI for factory automation<br />

General machine construction<br />

Food and beverage industry, pharmaceuticals<br />

Oil & gas, chemical industry and shipbuilding<br />

Customized products for various industries are developed and<br />

produced in association with a customized product agreement.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Customized Automation<br />

Examples of sector products<br />

Examples of sector products<br />

Examples:<br />

Application area Renewable energy:<br />

- SIMATIC Rack <strong>PC</strong> with flexible expansion<br />

- SIMATIC Box <strong>PC</strong>: 627/427 with QNX<br />

Use in the automobile industry:<br />

- HMI operator stations<br />

- Push Button Panels PP17-I PROFIsafe, PP17-I PN,<br />

PROFisafe. PP17-II PN<br />

- Front panel for Panel <strong>PC</strong>, 15" with arrow keys on the side<br />

- Mobile Panel 277 10" Remote Operate<br />

Application area mechanical equipment manufacture,<br />

general:<br />

- HMI RFID module<br />

- MP 177 6" Touch portrait format<br />

- Touch and Key front panel 15" for Panel <strong>PC</strong>,<br />

resistant to honing oil<br />

- Flat Panels 6.4" and 10.4" for Panel <strong>PC</strong><br />

Area of application food and beverage industry and<br />

pharmaceuticals:<br />

- Panels and Panel <strong>PC</strong>s with stainless steel front<br />

- HMI panels as rear-mounting devices<br />

- Flat Panel 15" and 19" Touch with stainless steel front<br />

- HMI stainless steel operator stations<br />

Area of application oil & gas, chemicals and shipbuilding:<br />

- MP 377 15" Touch daylight readable<br />

- TEK – Temperature Extension Kit<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6/33<br />

6


6<br />

Customized Automation<br />

Renewable energy<br />

Solar systems<br />

■ Overview<br />

Solar systems<br />

Compared to other power plants, photovoltaic systems are<br />

subject to hardly any mechanical stress and therefore require<br />

little maintenance. The same also applies for solar and solarthermal<br />

systems. This also reduces the maintenance overhead<br />

on the devices. The SIMATIC Industrial <strong>PC</strong>s and Panels meet<br />

these requirements through the targeted selection of highquality<br />

components and special production processes.<br />

■ Benefits<br />

SIMATIC Box <strong>PC</strong> family with mounting bracket for front mounting in<br />

portrait format<br />

Long service life<br />

Extra long spare parts availability<br />

Adapted computing power<br />

High system availability<br />

Individually adaptable<br />

6/34<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Application<br />

All SIMATIC Panels and I<strong>PC</strong>s are developed for especially<br />

demanding environments and also for long service life. Spare<br />

parts availability for many years secures use in sound solar and<br />

photovoltaic systems.<br />

Rugged:<br />

Ambient temperatures of 0 °C to +55 °C offer high flexibility<br />

in the choice of installation location. Use of a TEK is<br />

recommended for increasing the temperature range<br />

(see Chapter: Temperature Extension Kit).<br />

Innovative and flexible:<br />

- We meet the ever-increasing demand for more computing<br />

power by using the current generation of processors from<br />

Intel ® . Based on the current chipsets, devices are available<br />

with CeleronM, Core2 Solo, Core2 Duo and Core2 Quad.<br />

This makes power-saving applications (e.g. simple data<br />

acquisition) just as possible as power-hungry applications<br />

(such as the software PLC in real-time WinAC RTX) and<br />

server systems.<br />

- The SIMATIC I<strong>PC</strong>s fit into any control cabinet. Different<br />

mounting methods enable a host of installation versions.<br />

Optimized equipping of the Panels and I<strong>PC</strong>s for more system<br />

availability is one of the simplest options for increasing productivity<br />

by means of reducing standstill times.<br />

Electromechanical components often cause malfunctions in<br />

<strong>PC</strong>s. Since hard disks and fans in the industrial <strong>PC</strong> usually<br />

operate continuously, they are subject to an especially high rate<br />

of wear and tear. Software options for diagnostics and data<br />

backup, such as SIMATIC I<strong>PC</strong> DiagMonitor or SIMATIC I<strong>PC</strong><br />

Image Creator, are particularly effective here, in addition to the<br />

use of high-quality industrial grade components.


■ Overview<br />

Wind farms<br />

Wind farms can be used to produce electrical power in all<br />

climatic zones, at sea, and in all types of terrain. The requirements<br />

regarding the control systems for wind turbines and wind<br />

parks are as diverse as the installation locations.<br />

These locations are increasingly difficult to reach. This means<br />

the equipment must be completely maintenance-free. The<br />

Industrial <strong>PC</strong>s of the 427 series can meet these requirements.<br />

By selecting high-quality components and special production<br />

procedures, all the SIMATIC I<strong>PC</strong>s and Panels can be used for<br />

several years without requiring servicing.<br />

■ Benefits<br />

SIMATIC I<strong>PC</strong>427C with expansion frame<br />

Suitable for special temperature requirements<br />

Maintenance-free for offshore use<br />

Can handle high mechanical load<br />

High system availability<br />

Individually adaptable<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Application<br />

Customized Automation<br />

Renewable energy<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Wind farms<br />

All SIMATIC Panels and I<strong>PC</strong>s are developed for especially<br />

demanding environments. The devices are optimally equipped<br />

to deal with vibration in wind turbines: rugged enclosures,<br />

special hard disk brackets, and interlocks are just a few<br />

examples of standard features on SIMATIC devices.<br />

Rugged:<br />

- The SIMATIC I<strong>PC</strong>s fit into any control cabinet. Different<br />

mounting methods enable a host of installation versions.<br />

Ambient temperatures of 0 °C to +55 °C are supported on<br />

the I<strong>PC</strong>427C, with much higher temperatures in some applications.<br />

Use of a TEK is recommended for extreme temperatures<br />

(see Chapter: Temperature Extension Kit).<br />

- Salt-laden atmospheres are hard on the devices.<br />

SIMATIC Panels are also available in the IP65 type and are<br />

thus eminently suitable for offshore use. Versions of the<br />

Microbox 427C also enable use in salt-laden atmospheres:<br />

this is made possible by special paint processes that have<br />

been in use for many years.<br />

Innovative and flexible:<br />

We meet the ever-increasing demand for more computing<br />

power by using the current generation of processors from<br />

Intel ® . Based on current chipsets, devices with Celeron M,<br />

Core2 Solo, Core2 Duo and Core2 Quad are available.<br />

This makes power-saving applications (e.g. simple data<br />

acquisition) just as possible as power-hungry applications<br />

(such as the software PLC in real-time WinAC RTX) and server<br />

systems.<br />

Optimized equipping of the I<strong>PC</strong> and the Panel for more system<br />

availability is one of the simplest options for increasing productivity<br />

by means of reducing standstill times.<br />

Electromechanical components often cause malfunctions in<br />

<strong>PC</strong>s. Since hard disks and fans in the industrial <strong>PC</strong> usually<br />

operate continuously, they are subject to an especially high rate<br />

of wear and tear. Software options for diagnostics and data<br />

backup, such as SIMATIC I<strong>PC</strong> DiagMonitor or SIMATIC I<strong>PC</strong><br />

Image Creator, are particularly effective here, in addition to the<br />

use of high-quality industrial grade components.<br />

6/35<br />

6


6<br />

Customized Automation<br />

Automotive industry<br />

HMI operator stations<br />

■ Overview<br />

Operator <strong>PC</strong> unit operator panel + PLC and operator terminal (OT)<br />

The fully-equipped and wired turnkey solutions in a variety of designs are<br />

ideal for the requirements of the automotive industry.<br />

6/36<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Modern design combined with outstanding functionality<br />

Increased heat dissipation thanks to ribbed aluminum profile<br />

and backpanel heat sink<br />

Easy access to controls thanks to hinged front frame or hinged<br />

backpanel<br />

Modular system for precise customization and tailoring to<br />

Panel or Panel <strong>PC</strong><br />

High-quality aluminum press-drawn section with clean<br />

surface finish<br />

Colors to complement design, also possible in customized<br />

RAL colors<br />

Rugged and maintenance-friendly device design<br />

Very high EMC<br />

Distributed configuration for large machines and distributed<br />

installations<br />

Optimized high-speed operator control thanks to:<br />

- Reduced number of operator controls<br />

- Optimum control element layout<br />

- 24 V DC hardware<br />

- Direct keys or high-speed PROFIBUS communication for<br />

direct keys<br />

Use of high-capacity mass storage for large software<br />

applications<br />

Silicone-free device configuration<br />

Chemically-resistant surfaces (resistant to lubricants and<br />

fillers, oils, etc., in particular)<br />

Welding sputter-resistant surface<br />

Project-specific software ready installed<br />

■ Application<br />

In automotive industry, the fault-free operation of production<br />

facilities is of paramount importance. The requirements of<br />

industrial control enclosures in respect of impermeability to dust<br />

and water, as well as those in respect of the management of the<br />

internal heat balance are therefore very high. In addition to the<br />

HMI I<strong>PC</strong>477C and HMI I<strong>PC</strong>577C, the HMI I<strong>PC</strong>677C and<br />

Flat Panels are also suitable for use as operator <strong>PC</strong>s in the<br />

automotive industry.


■ Design<br />

The modular design with a variety of aluminum frame and<br />

expansion profiles can support all required device<br />

combinations. A variety of operator stations appear in the<br />

overview:<br />

- Modular aluminum control housing system for the<br />

combination of a number of HMI Panels, Panel <strong>PC</strong>s and<br />

SIMATIC S7 PLCs (see page 6/36)<br />

- Modular aluminum control housing system for the<br />

combination of a number of HMI Panels (see page 6/36)<br />

- Modular aluminum control housing system for the installation<br />

of an HMI Panel or Panel <strong>PC</strong> (see page 6/36)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Locking E1-locking for enclosure lock<br />

E7 key-operated switch<br />

Mounting Installation in operator panel enclosure<br />

with electrical wiring<br />

Customized Automation<br />

Automotive industry<br />

HMI operator stations<br />

Can be accessed via hinged front frame or hinged backpanel<br />

Integrated support arm elements at the top and bottom for the<br />

direct attachment of support arm couplings<br />

Integrated handle attachments facilitate handling and<br />

underline the design image<br />

Certifications/Approvals<br />

IP65<br />

NEMA 4/EEMAC Type 12<br />

cULus<br />

CE<br />

■ Technical specifications<br />

Examples from the automotive industry<br />

Type<br />

Components<br />

HMI operator control unit Operator <strong>PC</strong> unit operator panel + PLC<br />

Computing unit SIMATIC HMI I<strong>PC</strong>677C <strong>PC</strong> Box based on SIMATIC HMI I<strong>PC</strong>677C<br />

Core i7, 2.53 GHz, 4 GB RAM<br />

Core i7, 2.53 GHz, 4 GB RAM<br />

250 GB HD,<br />

250 GB HD,<br />

PROFINET + 2 x Ethernet interfaces 10/100 Without MPI/PROFIBUS + 2 x Ethernet<br />

Mbit<br />

interface 10/100 Mbit<br />

Europe default 230 V<br />

Europe default 230 V<br />

Front panel SIMATIC HMI I<strong>PC</strong>677C 15" Touch,<br />

15" XGA 1024x768 resolution<br />

Customized front with 2x6 control keys,<br />

15" XGA 1024x768 resolution<br />

Additional components<br />

Additional components<br />

PP17-I PROFIsafe<br />

PP17-II<br />

S7-400 configuration<br />

Operator panel enclosure CC-4000, mounted on stand VIP 6000 (upper part)<br />

IW 6900 (lower part)<br />

Dimensions 578 x 764 x 183 mm 630 x 1870 x 636 mm<br />

Operator panel with slide-in label –<br />

Keyboard Sasse stainless steel keyboard IP65 Sasse stainless steel keyboard IP65<br />

Mouse Track-Ball integrated in the keyboard Optical mouse<br />

Elements 3 x 3SB3 elements with labeling plates, 2 x 4 operator controls,<br />

1 x Emergency Off,<br />

1x machine circuit-breaker, signal light<br />

processing possible<br />

1 x Emergency Stop<br />

Customized enclosure lock<br />

Installation in operator panel enclosure<br />

with electrical wiring<br />

Ventilation – –<br />

Terminals Use of 3-wire terminals Use of Wago terminals<br />

Core identification Yes Yes<br />

Base profile Icotec<br />

Icotec<br />

RJ45 Ethernet port<br />

RJ45 Ethernet port<br />

Software: Windows 7, MUI<br />

Windows 7, MUI<br />

WinCC V7.x<br />

SIMATIC Softnet S7 for IE V 6.x<br />

SIMATIC <strong>ST</strong>EP 7 Prof V5.x<br />

SIMATIC <strong>ST</strong>EP 7 V 5.x<br />

SIMATIC S7-Graph V 5.x<br />

SIMATIC DistributedSafety V 5.x<br />

InTouch Runtime V 9.x<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6/37<br />

6


6<br />

Customized Automation<br />

Automotive industry<br />

HMI operator stations<br />

■ Technical specifications (continued)<br />

Type Operator terminals (OTs)<br />

Components PP17-I PROFIsafe<br />

PP17-II<br />

TP 177B<br />

Additional components<br />

Operator panel enclosure VIP 6000<br />

Dimensions 622 x 585.5 x 210 mm<br />

Elements 16 short-stroke keys,<br />

2 x 4 add-on controls,<br />

1 x EMERGENCY <strong>ST</strong>OP<br />

32 short-stroke keys<br />

3 x SIMATIC DP interface<br />

connectors<br />

Locking Customized enclosure lock<br />

Mounting Installation in operator panel<br />

enclosure with electrical wiring<br />

Core identification Yes<br />

6/38<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ More information<br />

Quotation preparation<br />

Product specification according to customer requirements.<br />

Quotation preparation by SIMATIC HMI specialists,<br />

specification of:<br />

Non-recurring costs<br />

Prototype costs<br />

Standard unit prices<br />

General conditions (product agreement)<br />

There is a minimum annual quantity/purchase quantity (minimum<br />

quantity per type: 20), which is agreed with the customer for the<br />

project.<br />

Customized products can only be ordered in conjunction with a<br />

product agreement.<br />

A customer-specific order number is allocated during the<br />

product agreement process.<br />

SIMATIC contacts in your area<br />

www.siemens.com/automation/partners


■ Overview<br />

Push Button Panel PP17<br />

Product overview PROFIBUS,<br />

MPI<br />

Standard Products<br />

- PP17-I<br />

- PP17-II<br />

Industry-specifi c<br />

products<br />

- PP17-I PN PROFIsafe<br />

- PP17-II PN<br />

- PP17-II PN PROFIsafe<br />

PP17-I<br />

PP17-II<br />

PP17-I PROFINET: Front and rear views<br />

PROFINET with /<br />

without PROFIsafe<br />

PP17-I PN PS<br />

PP17-II PN<br />

PP17-II PN PS G_<strong>ST</strong><strong>80</strong>_XX_00352<br />

PP17 Push Button Panels with PROFINET communication as well<br />

as connections for emergency stop via F-DI are sector-specific<br />

expansions to the spectrum of Standard Push Button Panels.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Customized Automation<br />

Automotive industry<br />

PP17 with PROFIBUS and PROFINET<br />

The control unit offers a wide range of features that can be used<br />

without the need for programming.<br />

Basic features:<br />

Short-stroke keys with durable surface LEDs<br />

LED colors red, green, yellow<br />

Additional 24 V digital inputs and digital outputs<br />

Short-stroke keys and digital inputs can also be individually<br />

configured as switches<br />

Integrated lamp and button test<br />

Integrated flash rate<br />

LEDs for POWER and ERROR indication<br />

Non-interchangeable coded plug-type terminals<br />

SIMATIC HMI operator panel design, can be mounted laterally<br />

In addition to the basic features, the following is offered with the<br />

PP17 PN:<br />

LEDs for monitoring the PROFINET communication<br />

PROFINET communication, line-capable<br />

In addition to the basic features, the PP17 PN PS offer the<br />

following:<br />

Pre-perforated cut-outs for 22.5 mm standard add-on<br />

components such as key switches and emergency stop<br />

(PP17-I PN PS)<br />

DIL switch for setting the PROFIsafe address<br />

Fail-safe operation of emergency stop buttons by using<br />

PROFIsafe communication<br />

Simultaneous standard mode and fail-safe mode<br />

Non-interchangeable coded plug-in terminals<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6/39<br />

6


6<br />

Customized Automation<br />

Automotive industry<br />

PP17 with PROFIBUS and PROFINET<br />

■ Application<br />

The Push Button Panel has been designed for use in the<br />

automotive industry.<br />

Possible applications for the operator panel<br />

The operator panel is used to display the operating states of<br />

machines or plants and to control the process. The operator<br />

panel is designed for mounting in control panels and replaces<br />

individually installed and wired keys, switches and lamps or<br />

LEDs. The operator panel can be mounted in an installation<br />

cut-out and connected to a controller of type SIMATIC S7-300 or<br />

S7-400 via the bus system. The operator panel is pre-configured<br />

and is operational almost immediately. In comparison to conventional<br />

wiring, substantially less time is needed for commissioning<br />

and the device provides increased failure safety during runtime.<br />

■ Design<br />

External dimensions and mounting cutout are the same as those<br />

for the standard product PP17-I or PP17-II.<br />

PP17-I PROFINET-PROFIsafe<br />

6/40<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Use in fail-safe mode<br />

Thanks to integrated PROFIsafe communication, the operator<br />

panel can be utilized in fail-safe mode with SIMATIC S7-300F or<br />

S7-400F for simple emergency stop applications. Maximum two<br />

2-channel emergency stop buttons can be connected. With<br />

regard to safety-relevant signals, SIL 3, PL e can be achieved.<br />

The fail-safe operator panel features a simple non-configurable<br />

diagnostic function. The diagnostics are always activated and<br />

are automatically made available by the HMI device in <strong>ST</strong>EP 7<br />

and passed on to the CPU in the event of a fault.<br />

The diagnostic function passes the following diagnostic<br />

information to the CPU:<br />

Communication error<br />

Communication between the operator panel and the CPU has<br />

been interrupted (e.g. due to an incorrect bus address or<br />

PROFIsafe address).<br />

Hardware error<br />

External wiring or internal hardware error, data corruption or<br />

procedural error.<br />

Parameterization error<br />

Error in the PROFIsafe configuration


For further technical specifications, refer to the respective<br />

operating instructions.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Customized Automation<br />

Automotive industry<br />

PP17 with PROFIBUS and PROFINET<br />

■ Technical specifications<br />

PP17-I PN PROFIsafe PP17-II PN PP17-II PN PROFIsafe<br />

Operator controls<br />

Short-stroke keys 16 32 32<br />

Number of connectable<br />

Emergency Stop buttons<br />

1 to 2 --- 1 to 2<br />

Maximum cable length 10 m --- 10 m<br />

Discrepancy time 500 ms --- 500 ms<br />

Response time<br />

Functionality<br />

40 to 70 ms --- 40 to 70 ms<br />

Enable input Yes Yes Yes<br />

Slots for 22.5 mm standard elements max. 12 --- ---<br />

Non-interchangeable coded plug-type<br />

terminals<br />

Interfaces<br />

Yes --- Yes<br />

PROFIBUS DP --- --- ---<br />

Ethernet 2 x RJ45 10/100 Mbit<br />

2 x RJ45 10/100 Mbit<br />

2 x RJ45 10/100 Mbit<br />

for line topologies<br />

for line topologies<br />

for line topologies<br />

Connection to controller S7-300F, S7-400F S7-300, S7-400 S7-300F, S7-400F<br />

Protocol Standard communication PROFINET IO PROFINET IO PROFINET IO<br />

Fail-safe communication PROFIsafe V2 mode --- PROFIsafe V2 mode<br />

Additional digital inputs 16 16 16<br />

Additional digital outputs 8 16 8<br />

Output current 100 mA max. 100 mA max. 100 mA max.<br />

Summation current<br />

(per group of 8 outputs each)<br />

600 mA max. 600 mA max. 600 mA max.<br />

Short-circuit protection /<br />

electrical isolation<br />

Requirements<br />

Yes/--- Yes/--- Yes/---<br />

Basic package <strong>ST</strong>EP 7 V5.4 from SP1 <strong>ST</strong>EP 7 V5.4 from SP1 <strong>ST</strong>EP 7 V5.4 from SP1<br />

Option package SIMATIC S7 – Distributed Safety --- SIMATIC S7 – Distributed Safety<br />

V5.4 and higher<br />

V5.4 and higher<br />

Certification<br />

HSP (Hardware Support<br />

Package)<br />

HSP (Hardware Support Package)<br />

cULus, CE,<br />

cULus, CE cULus, CE,<br />

SIL 3, PL e<br />

SIL 3, PL e<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6/41<br />

6


6<br />

Customized Automation<br />

Automotive industry<br />

PP17 with PROFIBUS and PROFINET<br />

■ Ordering Data Order No. Order No.<br />

SIMATIC PP17-I PN PROFIsafe 6AV3 688-4CX07-0AA0<br />

Push Button Panel with<br />

16 short-stroke keys and<br />

22.5 mm cut-outs for operator<br />

controls, PROFINET communication,<br />

PROFIsafe communication<br />

and max. 2 F-DI for emergency<br />

stop applications,<br />

incl. mounting accessories and<br />

1 sheet of slide-in labels<br />

Delivery time<br />

Minimum quantity<br />

Available ex stock<br />

None; can be ordered individually<br />

Project quantities or<br />

ongoing supply<br />

Orders as per<br />

customer forecast<br />

1) For ongoing supply or the delivery of larger quantities to OEM<br />

customers, product planning and production are based on customer<br />

forecasts.<br />

1)<br />

Repairs only identified repairs<br />

SIMATIC PP17-II PN<br />

Push Button Panel with<br />

32 short-stroke keys,<br />

PROFINET communication,<br />

incl. mounting accessories and<br />

1 sheet of slide-in labels<br />

6AV3 688-4EY06-0AA0<br />

Delivery time Available ex stock<br />

Minimum quantity None; can be ordered individually<br />

Project quantities or ongoing<br />

supply<br />

Orders as per<br />

customer forecast 1)<br />

Repairs through spare-parts service<br />

SIMATIC PP17-II PN PROFIsafe<br />

Push Button Panel with<br />

32 short-stroke keys,<br />

PROFINET communication with<br />

PROFIsafe message frame and<br />

2 F-DI for emergency stop<br />

applications,<br />

incl. mounting accessories and<br />

1 sheet of slide-in labels<br />

6AV3 688-4EY07-0AA0<br />

Delivery time Available ex stock<br />

Minimum quantity None; can be ordered individually<br />

Project quantities or ongoing<br />

supply<br />

Orders as per<br />

customer forecast 1)<br />

Documentation<br />

Operating instructions<br />

Only available by download<br />

PP17-I PN PROFIsafe,<br />

PP17-II PN,<br />

PP17-II PN PROFIsafe<br />

and software, with Word template<br />

for writing the slide-in labels,<br />

with GSD file<br />

English Download: http://<br />

support.automation.siemens.com<br />

/WW/view/en/25023739<br />

Accessories for<br />

supplementary ordering<br />

Set of slide-in labels 6AV3 671-8CB00<br />

with 4 sets<br />

Repairs through spare-parts service<br />

■ More information<br />

www.siemens.com/automation/partner<br />

6/42<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Overview<br />

Front panel 15" with function keys at the side for Panel <strong>PC</strong> in<br />

the automotive industry<br />

The front panel 15.1" with arrow keys at the side is designed as<br />

a front unit for Panel <strong>PC</strong>. The arrow keys at the side allow intuitive<br />

and direct activation of movements in the plant.<br />

The display is a pure display unit, alphanumeric characters are<br />

entered using an external keyboard and external pointing<br />

device.<br />

■ Benefits<br />

Display unit with additional function keys for efficient and<br />

direct activation of motions<br />

Display surface resistant to welding beads<br />

24 V DC function keys for wiring to digital inputs of controller<br />

Non-interchangeable terminals<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Application<br />

Customized Automation<br />

Automotive industry<br />

Front panel with arrow keys on the side<br />

Application example: Operations computer in the automotive industry<br />

The front panel for Panel <strong>PC</strong>s with function keys at the side is<br />

designed for operator control and monitoring in the automotive<br />

industry, e.g. as a display for control computers.<br />

The front unit as the display unit with function keys at the side is<br />

always used if comprehensive inputs are necessary using an<br />

external keyboard and pointing device, but where efficient<br />

control of movements should be additionally possible using the<br />

function keys assigned to the graphics and directly to the PLC.<br />

■ Design<br />

2 x 6 function keys (24 V DC) on left and right of display<br />

Function keys connectable using non-interchangeable<br />

terminals, e.g. using vacant inputs of a Push Button Panel to<br />

the control<br />

Display surface resistant to welding beads<br />

USB interface at the front<br />

External dimensions and mounting cutout as for<br />

corresponding standard product<br />

IP65 degree of protection at the front<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6/43<br />

6


6<br />

Customized Automation<br />

Automotive industry<br />

Front panel with arrow keys on the side<br />

■ Technical specifications<br />

Type Front panel 15"<br />

with lateral function keys<br />

Display 15.1" TFT<br />

Resolution (pixels) 1024 x 768 pixels<br />

General features As for 15.1" front panel<br />

for HMI I<strong>PC</strong>677C<br />

Special features<br />

Interfaces USB interface at the front<br />

Connectable to Panel <strong>PC</strong> HMI I<strong>PC</strong>477C, HMI I<strong>PC</strong>677C,<br />

compact and distributed design<br />

Number of keys 2 x 6 function keys (24 V DC) on<br />

left and right of display, wired to<br />

terminals<br />

Modification possibilities<br />

Customized design<br />

Modification of front design<br />

6/44<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ More information<br />

Quotation preparation<br />

Product specification according to customer requirements.<br />

Quotation preparation by SIMATIC HMI specialists,<br />

specification of:<br />

Non-recurring costs<br />

Prototype costs<br />

Standard unit prices<br />

General conditions (product agreement)<br />

There is a minimum annual quantity/purchase quantity (minimum<br />

quantity per type: 20), which is agreed with the customer for the<br />

project.<br />

Customized products can only be ordered in conjunction with a<br />

product agreement.<br />

A customer-specific order number is allocated during the<br />

product agreement process.<br />

SIMATIC contacts in your area<br />

www.siemens.com/automation/partners


■ Overview<br />

Front view<br />

For high-contrast and clearly readable display of already<br />

configured SIMATIC WinCC process pictures of a stationary<br />

operator panel (e.g. with <strong>PC</strong> 677) without further configuring<br />

and adaptation overhead<br />

Server and client optimized for the following resolutions:<br />

- Remote Operate Server with 1024 x 768 pixels<br />

- Remote Operate Client with <strong>80</strong>0 x 600 pixels.<br />

Features<br />

- High-resolution display 10" SVGA<br />

- Integrated acknowledgment and stop button<br />

(safety category 3 in accordance with EN 954-1)<br />

- Rugged and double-panel enclosure<br />

(drop height 1 m, complete IP65 degree of protection)<br />

- Thin Client concept:<br />

Communication with the higher-level operator station using<br />

Remote Operate software and via PROFINET<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Application<br />

Customized Automation<br />

Automotive industry<br />

Mobile Panel 277 10" Remote Operate<br />

RO Client <strong>80</strong>0 x 600 pixels and RO Server 1024 x 768 pixels<br />

The SIMATIC Mobile Panel 277 10" Remote Operate (RO) from<br />

<strong>Siemens</strong> bridges the gap between flexible use through portability<br />

and ease of handling, and the benefits of a Thin Client<br />

concept.<br />

Existing WinCC configurations of a Panel <strong>PC</strong> 677 15" can be<br />

represented with functional compatibility. Reliable data transfer<br />

and short response times are guaranteed here. Operator input<br />

using the touch screen is intuitive. The optional device holder<br />

enables secure storage or stationary operation of the Mobile<br />

Panel.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6/45<br />

6


6<br />

Customized Automation<br />

Automotive industry<br />

Mobile Panel 277 10" Remote Operate<br />

■ Design<br />

Rear view and side view<br />

User-friendliness and ergonomic use were consistent design<br />

considerations. With its low weight and compact design, the<br />

Mobile Panel sits comfortably in the hand.<br />

The Mobile Panels are extremely impact-resistant thanks to the<br />

double-panel design and the rounded enclosure shape. The<br />

<strong>ST</strong>OP button is protected by a "collar" against unintentional use<br />

and against damage when dropped. Harsh industrial environments<br />

present no problems to the SIMATIC Mobile Panels with<br />

their dust and spray-water-protected enclosures in degree of<br />

protection IP65.<br />

The Mobile Panel is simply connected wherever it is needed in<br />

the plant. The rugged connection box with degree of protection<br />

IP65 can be installed anywhere. It ensures fault-free connection<br />

and disconnection during normal operation and thus enables<br />

the operator-control locations to be easily and safely changed<br />

when several connection points are available in a plant.<br />

The cable is up to 25 meters in length and handles power<br />

supply, transfer of the <strong>ST</strong>OP and acknowledgment button<br />

signals, and also data communication.<br />

The device has no rotating media.<br />

6/46<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Mode of operation<br />

All applications are run on the Remote Operate Server, which in<br />

turn handles any control connection to the production process.<br />

The user now decides which applications will be operated and<br />

monitored from the Mobile Panel. The plant operator hardly<br />

notices that he or she is now working on the main operator<br />

station and no longer locally.<br />

The device does not process the data locally, but instead<br />

accesses the data of up to ten selectable main operator stations<br />

with the help of the pre-installed Remote Operate Client<br />

software.<br />

These main operator stations are, in turn, equipped with the<br />

Remote Operate Server software. All stations are connected via<br />

Industrial Ethernet.<br />

The Mobile Panel is thus optimized exclusively on the visualization<br />

and management of the different stationary operator<br />

stations.<br />

Communication with the higher-level operator station takes<br />

place via the Remote Operate software and is enabled via<br />

PROFINET.<br />

■ Function<br />

Automatic restart after switching on and display of the server<br />

selection list (up to 4 hierarchical levels and up to 10 servers)<br />

Password protection<br />

Automatic Reconnect of client<br />

Operation authorization indication (traffic light) on the server<br />

and client<br />

Sophisticated safety concept<br />

The Mobile Panel has an acknowledgement button (in accordance<br />

with EN 60204-1) with three switching steps. This can be<br />

adjusted to an ergonomic position for both left-handed users<br />

and right-handed users simply by turning.<br />

The <strong>ST</strong>OP pushbutton (acc. to EN 60204-1) can be looped<br />

into the EMERGENCY OFF circuit of a machine and<br />

positively latches when pressed. It is distinguished from an<br />

EMERGENCY-OFF button by its gray color. This ensures that it<br />

cannot be mistaken for the EMERGENCY-OFF equipment.<br />

The <strong>ST</strong>OP and acknowledgment buttons are implemented as<br />

double circuits in accordance with Safety Category 3 to<br />

EN 954-1.


Customized Automation<br />

Automotive industry<br />

Mobile Panel 277 10" Remote Operate<br />

■ Technical specifications ■ Ordering data Order No.<br />

Type Mobile Panel 277<br />

10" Remote Operate<br />

Display 10" touch screen SVGA with<br />

<strong>80</strong>0x600 pixels, TFT display with<br />

65,536 colors<br />

Operation Touch screen with captive stylus<br />

and stylus holder, three-level<br />

acknowledgment button (deadman's<br />

switch) integrated into the<br />

handle, stop button, function<br />

keys, key-operated switches and<br />

backlit pushbuttons as option.<br />

Suitable for left and right-handed<br />

operation<br />

Interfaces Hardwired connection line to<br />

connection box Plus for<br />

PROFINET/Ethernet and power<br />

supply (e.g. Mobile Panel 277 PN)<br />

Software Remote Operate Client software<br />

(Thin Client) on Windows CE 5.0,<br />

function-compatible representation<br />

of existing WinCC configurations/software<br />

applications of<br />

an existing server, e.g. <strong>PC</strong>677<br />

Ambient conditions Full IP65 degree of protection,<br />

ambient operating temperature<br />

0°C to 40°C, drop height to 1.0 m<br />

Certification CE, cULus, C-Tick, EMC<br />

compliance, prototype test<br />

(BG/BIA or SIBE Switzerland)<br />

In the accessories pack CD-ROM, operating instructions,<br />

programming manual for Remote<br />

Operate Software<br />

Options Membrane function keys, access<br />

control (key-operated switch),<br />

buttons, handwheel<br />

Weight 2.3 kg<br />

PN Plus connection box<br />

Interfaces 2 x Ethernet with 10/100 Mbit/s,<br />

integrated switch<br />

Expansion for operator-process<br />

communication<br />

Reconnection during operation<br />

without interrupting the<br />

emergency stop circuit,<br />

monitoring of the <strong>ST</strong>OP button,<br />

location recognition (through<br />

hardware)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Mobile Panel 277<br />

10" Remote Operate<br />

Configuration on request<br />

E 6AV6 645-7AB10-0AS0<br />

Connection box PN Plus<br />

Connecting cable<br />

A 6AV6 671-5AE11-0AX0<br />

5 m 6XV1 440-4BH50<br />

10 m 6XV1 440-4BN10<br />

25 m 6XV1 440-4BN25<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

■ More information<br />

Customer-specific modifications<br />

Individual company logo instead of the <strong>Siemens</strong> logo and<br />

changing the type designation<br />

Changing the keyboard colors, labeling, symbols and<br />

background color<br />

Possible options: Membrane function keys, access control,<br />

pushbuttons and handwheel<br />

Quotation preparation<br />

SIMATIC HMI specialists define the product modifications<br />

precisely in accordance with customer requirements.<br />

This is followed by drafting of a quote by SIMATIC HMI<br />

specialists, determining the following:<br />

Non-recurring costs<br />

Prototype costs<br />

Standard unit prices<br />

and the marginal conditions in the form of a product<br />

agreement (e.g. minimum quantity).<br />

The defined device can be easily ordered using this product<br />

agreement and a customized order number. Device fronts are to<br />

be stored and provided by the customer upon delivery<br />

completion.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6/47<br />

6


6<br />

Customized Automation<br />

General machine construction<br />

HMI RFID module<br />

■ Overview<br />

External RFID USB module:<br />

Read/write device in accordance with ISO 15693<br />

User identification on Multi Panels and Panel <strong>PC</strong>s with<br />

non-contact chip card<br />

Personnel access control<br />

Identification of spare parts<br />

6/48<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Benefits of use<br />

- RFID module can be easily integrated into<br />

HMI operator stations<br />

- RFID tag direct on the goods or the container<br />

- Password protection for data on the chip card<br />

Features<br />

- Bus Powered USB – no additional 24 V DC supply required<br />

- 3-color LED status signaling<br />

- Min. range 3 cm (typ. 6 cm for chip cards)<br />

- Card recognition < 1 s<br />

■ Application<br />

Contactless identification of authorized persons by means of<br />

chip card in accordance with ISO 15693, e.g. by means of<br />

existing company ID card, service pass, individual permit.<br />

Access authorization<br />

Operator documentation<br />

■ Function<br />

RFID technology for identification solutions in applications on<br />

SIMATIC HMI Multi Panels and Panel <strong>PC</strong>s.<br />

Drivers for HMI software on Windows operating systems<br />

XP professional, XP embedded, CE 5.0<br />

Reading data and writing data to the RFID tag (depending on<br />

type)<br />

Multitag detection through anti-collision sequence in<br />

accordance with ISO 15693<br />

Validity check of the tag in accordance with EUROMAP 65<br />

No encoding of the clearance, no clone capability<br />

Firmware update via USB<br />

Supported tags: Tag-it HF I standard and Plus,<br />

I-Code SLISL2<br />

The following functions are among those supported by the<br />

software API<br />

RFID solutions for a wide variety of market segments:<br />

Callback function (new data available)<br />

Reading/writing of data arrays<br />

LED signaling<br />

Read out errors/faults (e.g. device defective, card read error)<br />

Configuring (e.g. operating mode)<br />

Read out module data (e.g. serial number)<br />

Output card UID in the sensing range<br />

Reading/writing of user-specific data<br />

Firmware update


■ Ordering data Order No.<br />

Customized Automation<br />

General machine construction<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

HMI RFID module<br />

■ Technical specifications<br />

■ More information<br />

HMI RFID delivery versions RFID USB chip card reader Customized modification options<br />

Principle Contactless, external<br />

Integration into customized operating fronts<br />

Interfaces and power supply 1 x UB 2.0, bus-powered,<br />

Adaptation of the membrane design<br />

Current consumption<br />

12 Mbit/s full speed<br />

200 mA<br />

Drafting a quotation<br />

Range Min. 3 cm (typ. 6 cm with tag<br />

antennas in credit card format)<br />

SIMATIC HMI specialists define the product modifications<br />

precisely in accordance with customer requirements.<br />

Card memory 2 Kbit,<br />

This is followed by drafting a quotation with:<br />

min. 256 bit freely writable<br />

Non-recurring costs<br />

Read/write frequency 13.56 MHz<br />

Prototype costs<br />

Response time Card recognition < 1 s<br />

Standard unit prices<br />

Panel cut-out W x H 82 x 69 mm<br />

and the marginal conditions in the form of a product<br />

Dimensions W x H x D 89.1 x 75.9 x 45 mm<br />

agreement (e.g. minimum quantity)<br />

Permissible ambient temperature<br />

Operation +5 °C to 55 °C (no condensation)<br />

The defined device can then be easily ordered using this<br />

product agreement and a customized order number.<br />

Storage -20 °C to +60 °C<br />

Degree of protection IP65 at front, IP20 at rear<br />

Standards ISO/15693<br />

Certification CE, UL/CSA, radio directives<br />

SIMATIC RFID<br />

chip card reader<br />

External RFID USB module<br />

A 6AV6 675-8XQ10-0AX0<br />

Starter Kit RFID<br />

chip card reader<br />

External RFID USB module<br />

Software on CD (USB driver)<br />

3 x chip cards<br />

Demo software (tool for reading<br />

and writing via WinXP)<br />

A 6AV6 675-8XQ00-0AX0<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6/49<br />

6


6<br />

Customized Automation<br />

General machine construction<br />

MP 177 6" Touch portrait<br />

■ Overview<br />

The use of panels in portrait format is required wherever installation<br />

space is restricted. The MP 177 6" Touch with portrait<br />

format expands the range of standard panels in customized<br />

projects.<br />

■ Benefits<br />

Portrait installation for narrow installation spaces at the<br />

machine<br />

Portrait format of the screen contents<br />

Engineering system adapted by means of add-on software:<br />

What you see is what you get.<br />

Field-proven functionality of the SIMATIC HMI standard<br />

products<br />

A compact combination of HMI and controller in conjunction<br />

with WinAC MP<br />

■ Application<br />

The MP 177 6" Touch portrait format is designed both for vertical<br />

installation with display of the screen contents in portrait format,<br />

and for WinAC MP applications.<br />

The device is suitable for use in machines with a narrow installation<br />

space, such as packaging machinery, baking machines,<br />

etc.<br />

6/50<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Design<br />

MP 177 6" Touch portrait format, an MP 177 turned through<br />

90° to the left<br />

The device is otherwise designed like the MP 177<br />

Angled adapter for communication:<br />

RS422/RS485 angled adapter<br />

■ Technical specifications<br />

MP 177 6" Touch portrait format<br />

Display 5.7" TFT color<br />

Resolution 240 x 320 pixels (QXGA)<br />

Note The modified alignment of the<br />

display and resolution must be<br />

taken into account when<br />

configuring the user interface.<br />

Special features<br />

Installation dimensions<br />

140 x 196<br />

(W x H in mm)<br />

The remaining technical<br />

specifications correspond<br />

to the MP 177 Touch<br />

6AV6 642-0EA01-3AX0<br />

■ Ordering data Order No.<br />

MP 177 6" Touch<br />

portrait format package<br />

Comprising<br />

MP 177 6" Touch with installation<br />

accessories, installation seal,<br />

power supply connector, and<br />

further accessories pack<br />

(insert and CD with add-on<br />

software for configuring<br />

portrait format)<br />

E 6AV6 642-7EA01-0AA0<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

■ More information<br />

Customized modification options<br />

Customized design<br />

Quotation preparation<br />

SIMATIC HMI specialists define the product modifications<br />

precisely in accordance with customer requirements.<br />

This is followed by drafting of a quote with:<br />

Non-recurring costs<br />

Prototype costs<br />

Standard unit prices<br />

and the marginal conditions in the form of a product<br />

agreement (e.g. minimum quantity)<br />

The defined device can then be easily ordered using this<br />

product agreement and a customized order number.


■ Overview<br />

The Front Panel Touch and Key is designed as a front unit for<br />

Panel <strong>PC</strong>s. The combination of Touch and Key operation as well<br />

as the resistance to honing oil are characteristics of this product.<br />

Complete lamination of the decoration foil over the touch area of<br />

the display increases the resistance against contamination and<br />

welding beads, and the absence of edges and joints facilitates<br />

cleaning. Openings and cutouts in the front have been<br />

completely omitted in favor of a homogenous surface which can<br />

also be used in the environment of honing oil and similar cooling<br />

agents and lubricants.<br />

Clear operation is achieved using the Touch pen which is<br />

delivered as standard and can be stored in a front holder. Dirty<br />

or oily hands are therefore not an argument against using a<br />

Touch screen. The pen has an ergonomic shape, is optimized for<br />

operations when wearing gloves, and is linked to the front using<br />

an elastic helix cable. Its "parking position" in the special<br />

stainless steel holder on the front means that it is always readily<br />

accessible.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Customized Automation<br />

General machine construction<br />

Front panel 15" Touch and Keys for Panel <strong>PC</strong>s,<br />

resistant to honing oil<br />

Combined Touch + Key operation for increased inefficiency<br />

Touch pen operation avoids contamination of the display area<br />

Ergonomically shaped touch pen which cannot be lost<br />

Simple cleaning<br />

Resistant to coolants and lubricants<br />

■ Application<br />

The front panel for Panel <strong>PC</strong>s with touch screen and membrane<br />

keyboard has been designed for operator control and<br />

monitoring at machine level for machine construction<br />

applications, where honing oil and lubricants are used.<br />

The touch and key front is always used if efficient operation of<br />

the machine is associated with the following requirements:<br />

Intuitive operation using graphic representation on display<br />

Specific command inputs using fixed command inputs<br />

Effective inputs in forms using the integrated numeric and<br />

alphanumeric keyboard<br />

Also in applications with increased environmental influences<br />

such as dirt and oil. The homogenous foil surface without joints<br />

or edges permits easy cleaning, and is resistant to coolants and<br />

lubricants.<br />

Application examples<br />

Printing machines<br />

Drilling, milling, honing machines<br />

Brake test stands<br />

Injection molding machines<br />

Building management<br />

Warehouse systems<br />

Automotive industry<br />

■ Design<br />

External dimensions and mounting cutout as for<br />

corresponding standard product<br />

Degree of protection IP65 at the front<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6/51<br />

6


6<br />

Customized Automation<br />

General machine construction<br />

Front panel 15" Touch and Keys for Panel <strong>PC</strong>s,<br />

resistant to honing oil<br />

■ Technical specifications ■ More information<br />

Type Front panel 15" Touch + Key,<br />

resistant to honing oil<br />

Display 15.1" TFT Touch<br />

Resolution (pixels) 1024 x 768 pixels<br />

General features As front panel 15.1" Touch<br />

for Panel <strong>PC</strong> 677<br />

Special features<br />

Interfaces Without front-sided USB interface<br />

Connectable to Panel <strong>PC</strong> <strong>PC</strong> 477, <strong>PC</strong> 677 compact and<br />

distributed design<br />

Number of keys 58 system keys and<br />

alphanumeric keys<br />

20 function keys with LED<br />

Resistance Tested with:<br />

Castrol Honilo 981 honing oil<br />

6/52<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Quotation preparation<br />

Product specification according to customer requirements.<br />

Quotation preparation by SIMATIC HMI specialists,<br />

specification of:<br />

Non-recurring costs<br />

Prototype costs<br />

Standard unit prices<br />

General conditions (product agreement)<br />

There is a minimum annual quantity/purchase quantity (minimum<br />

quantity per type: 20), which is agreed with the customer for the<br />

project.<br />

Customized products can only be ordered in conjunction with a<br />

product agreement.<br />

A customer-specific Order No. is allocated during the product<br />

agreement process.<br />

www.siemens.com/automation/partners


■ Overview<br />

Ideal for machine-level operator control and monitoring<br />

Especially suitable for use in machines with restricted<br />

installation space<br />

Can be modified in design and front mechanical components<br />

(e.g. stainless steel front for food and beverage industry)<br />

Distance between the Flat Panel and <strong>PC</strong> max. 30 m<br />

Functions correspond to the standard Flat Panels<br />

Available with and without touch operation<br />

VGA and SVGA resolution<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Application<br />

Customized Automation<br />

General machine construction<br />

Flat Panels 6.4" and 10.4" for Panel <strong>PC</strong><br />

The Flat Panels 6.4" TFT Touch and 10.4" TFT Touch have been<br />

designed as display and operator control units for industrial <strong>PC</strong>s<br />

(e.g. SIMATIC Microbox 427B) and Panel <strong>PC</strong>s (e.g. <strong>PC</strong> 677B),<br />

and they can be separated from the computing unit by up to<br />

30 m.<br />

They supplement the SIMATIC standard products and are<br />

suitable for machine-level human machine interfacing when<br />

<strong>PC</strong> functionality is required but little space is available for<br />

installing a display. VGA and SVGA resolution also in a<br />

secondary display, e.g. Panel <strong>PC</strong> 677B.<br />

■ Technical specifications<br />

Flat Panel 6.4” 10.4”<br />

Resolution (pixels) 640 x 4<strong>80</strong> pixels <strong>80</strong>0 x 600 pixels<br />

Input unit Analog-resistive touch screen Analog-resistive touch screen<br />

MTBF (at 25 °C) 50 000 h 50 000 h<br />

Power supply 24 V DC, RoHS 24 V DC, RoHS<br />

Front dimensions (L x W x D in mm) 212 x 156 x 60 335 x 275 x 75<br />

Installation dimensions (L x W in mm) 197 x 141 310 x 248<br />

Certified in accordance with CE, UL, ULCSA<br />

Can be connected to Panel <strong>PC</strong> 677B, SIMATIC Rack and Box <strong>PC</strong><br />

Approx. weight in kg 0.87 0.<strong>80</strong><br />

■ Ordering data Order No. ■ More information<br />

Flat Panel 6" Touch A 6AV7 461-6TA00-0AA1<br />

Customized modification options<br />

SIMATIC Flat Panel 6.4" TFT with<br />

analog-resistive Touch Panel,<br />

resolution 640 x 4<strong>80</strong> pixels,<br />

24 V DC power supply, VGA,<br />

DVI-D interface,<br />

incl. VGA cable 1.8 m<br />

Customized design<br />

Modification of front design, e.g. stainless steel front<br />

Flat Panel 10" Touch<br />

SIMATIC Flat Panel 10.4" TFT with<br />

analog-resistive Touch Panel,<br />

resolution <strong>80</strong>0 x 600 pixels,<br />

24 V DC power supply, VGA,<br />

DVI-D interface,<br />

incl. VGA cable 1.8 m<br />

A 6AV7 461-7TA00-0AA1<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6/53<br />

6


6<br />

Customized Automation<br />

Food and beverage industry, pharmaceuticals<br />

Food and beverage industry, pharmaceuticals<br />

■ Overview<br />

The product examples described on the following pages cover<br />

a wide range of the most important requirements.<br />

■ Benefits<br />

Simpler cleaning thanks to resistant and rugged stainless<br />

steel front with smooth surface, and minimal grooves and<br />

gaps<br />

High degree of protection IP66K (TP 177B and MP 277<br />

additionally IP66K) on the front for increased sealing<br />

properties and ruggedness<br />

Food-standard sealing material and shatter protection for the<br />

display to prevent contamination of the foodstuffs<br />

Optimized frame design almost flush with the control cabinet<br />

so that liquids can run off<br />

Device front developed on the basis of EN 1672-2<br />

Decorative membrane tested against chemicals in<br />

accordance with DIN 42115, Part 2 1)<br />

Food-standard flat seal in accordance with<br />

FDA 21 CFR 177.2006<br />

Rear tensioning frame (included in scope of supply)<br />

for even application pressure of the seal<br />

External dimensions and mounting cutout as for<br />

corresponding standard product<br />

6/54<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Hygiene areas in food and beverage production, pharmaceuticals<br />

or fine chemicals all share one requirement: The devices<br />

and equipment must be easy to clean. The relevant directives,<br />

standards and legislative requirements must be observed,<br />

e.g. EHEDG, FDA, EN 1672-2 (Hygienic Design), GMP, LMHV,<br />

LMBG.<br />

However, optimization and versions in the device hardware are<br />

also perfectly possible:<br />

Degree of protection<br />

Ruggedness<br />

Temperature resistance<br />

Design and installation versions<br />

Suitable for clean rooms<br />

Certification in accordance with ATEX<br />

The aim is to find the cost-optimized solution for the specific<br />

application case.<br />

The overview below shows different features depending on the<br />

applications areas, from packaging to the wet area in<br />

processing.<br />

Applications<br />

Features Hygienic packaging Pharmaceuticals, Food and beverages,<br />

Abattoirs, meat processing<br />

fine chemicals bottle cleaning, bottle filling,<br />

laboratories<br />

Stainless steel front partially x x x<br />

Stainless steel control boxes x x x x<br />

Stainless steel fully enclosed x x x x<br />

Simple to clean x x x x<br />

No grooves and gaps, partially partially membrane-covered protective edge -<br />

no projections<br />

not always accepted<br />

Increased tightness - - x x<br />

Mechanical ruggedness,<br />

no membrane front<br />

- - partially x<br />

Suitable for high-pressure<br />

cleaning (IP69K)<br />

- - - partially<br />

ATEX Ex Zone 2/22 x x partially -<br />

High degree of protection for humid environments<br />

With low installation depth and rugged front, the SIMATIC HMI<br />

Standard Panels are eminently suitable for industrial and<br />

machine-level use.<br />

The Panels with stainless steel front are also even better<br />

equipped to meet the high requirements presented by the<br />

food and beverage production environment. IP66K degree of<br />

protection protects against water even with a jet strength of<br />

100 l/min at 10 bar from a distance of 2.5 m to 3 m. The<br />

optimized frame profile and almost flush-mounting of the<br />

device on the control cabinet allow liquids to run off.<br />

Installation of the operator panels in a stainless steel control<br />

cabinet as ready-to-use units is optionally available as a<br />

customized version.<br />

1) Special resistance requirements must be examined separately.


■ Benefits (continued)<br />

Certificates, listings and appraisals<br />

SIMATIC HMI products with stainless steel front, and the<br />

stainless steel operator panel, were subjected to some or all of<br />

the tests below and are listed or appraised in accordance with:<br />

High degree or protection IP66K, NEMA Type 4, 4x, 12<br />

CE-compliant, cULus-listed<br />

LGA mark "Hygiene tested"<br />

(Approval document No. 5664018)<br />

Expert appraisal of the Munich University of Technology,<br />

Research Center Weihenstephan, in accordance with EHEDG<br />

recommendation (Report No.126/01.03.2007)<br />

Clean room qualification by IPA Fraunhofer Institute<br />

(test report: Examination of the clean room suitability and<br />

ESD characteristics of Panel <strong>PC</strong>s from <strong>Siemens</strong> AG,<br />

Report No. SI 0810-450 of October 2008)<br />

Qualification for clean rooms<br />

High-quality products such as semiconductors, medicines,<br />

food & beverages, and nanotechnology products are subject to<br />

special demands with regard to contamination with particles or<br />

bacteria.<br />

Increased requirements for protection of the products and<br />

processes can only be met by production in clean rooms with<br />

suitable equipment under controlled conditions.<br />

Clean rooms are classified according to particle quantities and<br />

sizes per m3 of room air and time unit. Clean room classes in<br />

accordance with ISO 14644-1 (ISO 1 to 9) have been introduced<br />

in pharmaceuticals, for example, in accordance with EG-GMP,<br />

Annex 1 (Classes A to F), and in semiconductor production.<br />

Example:<br />

A person in normal clothing emits approximately<br />

<strong>80</strong>,000 particles >= 0.5 mm per second<br />

(in clean room clothing, this can be reduced to<br />

approximately 700 particles/s >= 0.5 mm).<br />

Requirements regarding equipment in clean rooms include<br />

the following:<br />

Surfaces that are easy to clean and disinfect<br />

As few adhesives as possible, e.g. electrostatic<br />

No emitting surfaces<br />

Shape favorable to air circulation, no air eddies<br />

Dense, as few hollow or dead spaces as possible<br />

Smooth, as few grooves and gaps as possible<br />

The SIMATIC HMI products with stainless steel front and the<br />

stainless steel operator panel have been designed for these<br />

requirements.<br />

The stainless steel operator stations with Panel <strong>PC</strong> 677B 15"<br />

Touch INOX and MP 377 15" Touch INOX have been tested by<br />

the Fraunhofer Institute and qualified for "obvious suitability for<br />

clean rooms of ISO Class 1 in accordance with EN ISO 14644-1".<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Customized Automation<br />

Food and beverage industry, pharmaceuticals<br />

■ Application<br />

Food and beverage industry, pharmaceuticals<br />

Quality and hygiene are decisive competitive features in the<br />

production of food and beverages. In addition, higher volumes<br />

have to be produced in shorter times and with rising quality<br />

demands.<br />

Objects and equipment that come into contact with food and<br />

beverages must be<br />

such that they are clean and can be maintained and, if<br />

necessary, disinfected, and have no adverse effect on the<br />

food and beverages<br />

installed in such a way that the immediate environment can be<br />

cleaned appropriately.<br />

Objects and equipment must be clean and well maintained<br />

(extract from the German food and beverages hygiene legislation).<br />

This requires not only the innovative know-how of<br />

engineering offices, mechanical equipment manufacturers and<br />

plant builders, but also modern, powerful operator control and<br />

monitoring systems whose hardware and software are adapted<br />

to the special requirements.<br />

The Panels and Panel <strong>PC</strong>s with touch screens and stainless<br />

steel fronts have been designed for use in the food, beverage<br />

and tobacco industry and for operator control and monitoring<br />

close to food processing machines. For this reason, the devices<br />

with stainless steel front have been developed in compliance<br />

with EN 1672-2 "Food processing machinery – Safety and<br />

Hygiene Requirements".<br />

Simpler cleaning and disinfecting<br />

The high quality requirements in the food and beverage industry<br />

require a high standard of the food processing machinery. There<br />

are many relevant regulations, directives, ordinances, standards<br />

and laws. Essential here is that all equipment and components<br />

must be easy to clean and disinfect so that cross-contamination<br />

of the foodstuffs can be avoided.<br />

The Panels with stainless steel front have a 240 grit hairline<br />

finish, so they are suitably smooth. The membrane covering the<br />

display cutout is tested with regard to its resistance to<br />

chemicals, has minimal grooves and gaps in which microorganisms<br />

could settle, and also provides shatter protection for<br />

the display.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6/55<br />

6


6<br />

Customized Automation<br />

Food and beverage industry, pharmaceuticals<br />

Panels and Panel <strong>PC</strong>s with stainless steel front<br />

■ Overview<br />

6/56<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Design<br />

External dimensions and mounting cutout as for<br />

corresponding standard product<br />

Optimized frame profile with a slight projection to the cabinet<br />

IP66K degree of protection at the front<br />

Surface ground with 240 grain abrasive<br />

Minimal number of grooves and joints<br />

Decorative film tested for resistance to chemicals<br />

Display splash protection<br />

Food-standard seals<br />

Rear tensioning frame for even application pressure of the<br />

seal<br />

TP 177B color PN/DP, MP 277 10" Touch, MP 377 15" Touch<br />

and Panel <strong>PC</strong> 677B 15"<br />

The SIMATIC Panels with touch screens and stainless steel<br />

fronts have been designed for use in the food, beverage and<br />

tobacco industry for operator control and monitoring close to<br />

food processing machines. They have been developed in<br />

compliance with EN 1672-2 "Food processing machines – Safety<br />

and Hygiene Requirements".<br />

Simple cleaning and disinfecting<br />

- Stainless steel surface with 240 grade hairline finish<br />

- Membrane tested for resistance to chemicals<br />

- Minimal number of grooves and joints<br />

- Optimized frame profile so that liquids can run off<br />

Display shattering protection<br />

Degree of protection IP66K<br />

■ Technical specifications<br />

Multi Panels<br />

MP 277 10" Touch INOX<br />

General features<br />

MP 377 15" Touch INOX<br />

Power supply 24 V DC 24 V DC<br />

Display 10.4" color TFT Touch 15.1" TFT Touch<br />

Resolution (pixels) 640 x 4<strong>80</strong> 1024 x 768<br />

MTBF of backlighting (at 25 °C)<br />

Front<br />

about 50 000 hours LED backlighting about 50 000 hours CCFL backlighting<br />

Material Stainless steel 1.4301, polyester-based membrane<br />

Surface Hairline finish, 240 grit abrasive grain<br />

Device seal<br />

Ambient conditions<br />

EPDM flat seal<br />

Degree of protection on the front: IP66K, NEMA 4, 4x and 12; on the rear: IP20<br />

Ambient temperature during<br />

operation<br />

0 ... 50 °C<br />

Relative humidity max. 85% (no condensation)<br />

Transport/storage temperature -20 °C to +60 °C<br />

Approvals FM Class 1 Div 2, cULus, CE, C-Tick, ATEX Zone 2/22<br />

Sector Food & beverages, pharmaceuticals Food & beverages, pharmaceuticals


■ Technical specifications (continued)<br />

Multi Panels<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Customized Automation<br />

Food and beverage industry, pharmaceuticals<br />

Panels and Panel <strong>PC</strong>s with stainless steel front<br />

HMI software (to be obtained<br />

separately)<br />

HMI engineering software<br />

Dimensions<br />

WinCC flexible 2005 Standard and higher WinCC flexible 2007 Standard and higher<br />

External dimensions<br />

(W x H x D in mm)<br />

325 x 263 400 x 310<br />

Installation cutout<br />

(W x H x D in mm)<br />

310 x 248 368 x 290<br />

Special features Clamping frame Clamping frame<br />

Weight Approx. 4.2 kg Approx. 6.2 kg<br />

Panel <strong>PC</strong> Panels<br />

Panel <strong>PC</strong> 677B 15" Touch INOX TP 177B PN/DP INOX<br />

General features<br />

Power supply 100/230 V AC (autorange), 50/60 Hz or 24 V DC 24 V DC<br />

Display 15.1" TFT Touch 5.7" color <strong>ST</strong>N Touch (256 colors)<br />

Resolution (pixels) 1024 x 768 320 x 240<br />

MTBF of backlighting (at 25 °C) about 50,000 hours CCFL backlighting<br />

Special features<br />

Front<br />

Without front USB interface 1 x emergency-off, 3 x short-stroke membrane keys<br />

with LED on front, wired to terminal<br />

Material Stainless steel 1.4301, polyester-based membrane<br />

Surface Hairline finish, 240 grit abrasive grain<br />

Device seal EPDM flat seal<br />

Special features<br />

Ambient conditions<br />

on the front: IP66K, NEMA 4, 4x and 12;<br />

on the rear: IP20<br />

Decorative membrane drawn across the display<br />

Degree of protection on the front: IP66K, NEMA 4, 4x and 12;<br />

on the front: IP66K, NEMA 4, 4x and 12;<br />

on the rear: IP20<br />

on the rear: IP20<br />

Ambient temperature during<br />

operation<br />

0 ... 50 °C 0 ... 50 °C<br />

Relative humidity max. 85% (no condensation)<br />

Transport/storage temperature -20 °C to +60 °C<br />

Approvals CE, cULus FM Class 1 Div 2, cULus, CE, C-Tick, ATEX Zone 2/22<br />

Sector<br />

HMI software<br />

(to be obtained separately)<br />

Food & beverages, pharmaceuticals Food & beverages, pharmaceuticals<br />

HMI engineering software WinCC flexible Advanced and higher WinCC flexible 2005 Compact and higher<br />

HMI Runtime software<br />

Dimensions<br />

WinCC flexible RT<br />

External dimensions<br />

(W x H x D in mm)<br />

483 x 310 212 x 156<br />

Installation cutout<br />

(W x H x D in mm)<br />

450 x 296 198 x 142<br />

Special features Clamping frame Clamping frame<br />

Can be connected to SIMATIC <strong>PC</strong> On Panel <strong>PC</strong>s as well as other SIMATIC Rack<br />

and Box <strong>PC</strong>s<br />

Weight Approx. 15 kg Approx. 1.5 kg<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6/57<br />

6


6<br />

Customized Automation<br />

Food and beverage industry, pharmaceuticals<br />

Panels and Panel <strong>PC</strong>s with stainless steel front<br />

■ Ordering data Order No. ■ More information<br />

TP 177B color PN/DP INOX E 6AV6 642-8BA10-0AA0<br />

Customized modification options<br />

With stainless steel front,<br />

Customized design<br />

otherwise like<br />

- Use of the company name instead of the <strong>Siemens</strong> logo and<br />

6AV6 642-0BA01-1AX0<br />

modification of the type designation<br />

MP 277 10" Touch INOX E 6AV6 643-0ED01-2AX0<br />

- Changing the background color<br />

With stainless steel front and<br />

LED backlighting, otherwise like<br />

6AV6 643-0CD01-1AX1<br />

Customer-specific hardware modifications such as the design<br />

and dimensions of the front plate, selection of the display,<br />

memory capacity, drives, options<br />

MP 377 15" Touch<br />

With stainless steel front and<br />

LED backlighting, otherwise like<br />

6AV6 644-0AB01-2AX0<br />

Panel <strong>PC</strong> 677B 15"<br />

With stainless steel front,<br />

otherwise like<br />

Panel <strong>PC</strong> 677B Configurator<br />

E 6AV6 644-0CB01-2AX0<br />

6AV7 872-2…<br />

Customer-specific Panel <strong>PC</strong> configuration as a rugged<br />

embedded hardware and software system, without hard disk<br />

and with tailor-made software<br />

Customer-specific software suite with choice of Windows<br />

operating systems<br />

Customer-specific Panel <strong>PC</strong>s with software suite with choice<br />

of Windows operating systems<br />

Protection against condensation and corrosive gases<br />

6AV6 643-0CD01-1AX1<br />

(for selected panels)<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU Device mounted in a stainless steel cabinet as a ready-toinstall<br />

and ready-to-connect terminal which is ergonomic,<br />

functional, with high degree of protection as well as tested<br />

heat dissipation (e.g. with complete degree of protection<br />

IP66K)<br />

Drafting a quotation<br />

SIMATIC HMI specialists define the product modifications<br />

precisely in accordance with customer requirements.<br />

This is followed by drafting a quotation with:<br />

Non-recurring costs<br />

Prototype costs<br />

Standard unit prices<br />

and the marginal conditions in the form of a product<br />

agreement (e.g. minimum quantity).<br />

The defined device can then be easily ordered using this<br />

product agreement and a customized Order No.<br />

6/58<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Overview<br />

MP 377 12" Touch, rear-mounting, MP 277 8" Touch vertical,<br />

rear-mounting<br />

The solution for installing HMI devices without "corners and<br />

edges" on the front. The devices are installed in the control<br />

cabinet enclosure from the rear and are flushed with the control<br />

cabinet sheet metal at the front. They are therefore known as<br />

"rear-mounting devices".<br />

■ Benefits<br />

Front surface flush with the control box<br />

Simple to clean<br />

No dirt-collecting edges and deposits<br />

Front membrane resistant to the usual cleaning agents and<br />

disinfectants<br />

Can be replaced with front-mounting device of the same type<br />

for service purposes (MP 377 12" Touch rear-mounting only)<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Customized Automation<br />

Food and beverage industry, pharmaceuticals<br />

■ Design<br />

HMI Panels as rear-mounted devices<br />

The front frame is modified customer-specifically on the<br />

"rear-mounting devices":<br />

The surface with the display viewing area covered with<br />

decorative membrane, and the marginal area around the display<br />

necessary for touch operation must be flush with the control<br />

cabinet sheet metal at the front. For this purpose, the front frame<br />

with the device seal and the cutouts for the holding bolts are set<br />

back from the visible surface by the thickness of the control<br />

cabinet sheet metal. The enclosure must have a suitable number<br />

of stud bolts available. The all-round device seal thus enables a<br />

high degree of protection: IP65.<br />

The installation cutout can be dimensioned in such a way that<br />

the rear-mounting device can be replaced with the same type of<br />

front-mounting device for service purposes.<br />

The decorative membrane is also drawn across the visible area<br />

of the display on the rear-mounting devices, so there is no cutout<br />

with adhesive edge above the display. The decorative<br />

membrane is smooth.<br />

For sensitive applications where the gap dimension of the<br />

control cabinet cutout has too great a tolerance, there is the<br />

option of covering the entire surface including the gap with a<br />

transparent and replaceable membrane.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6/59<br />

6


6<br />

Customized Automation<br />

Food and beverage industry, pharmaceuticals<br />

HMI Panels as rear-mounted devices<br />

■ Technical specifications<br />

MP 277 8" Touch vertical, rear-mounting MP 377 12" Touch, rear-mounting<br />

General features<br />

Power supply 24 V DC 24 V DC<br />

Display 7.5" TFT Touch 12.1" TFT Touch<br />

Resolution (pixels) 4<strong>80</strong> x 640 (portrait) <strong>80</strong>0 x 600<br />

MTBF of backlighting (at 25 °C) about 50,000 hours CCFL backlighting<br />

Special features<br />

Front<br />

1 x emergency-off, 3 x short-stroke membrane keys with LED on front, wired to terminal<br />

Material Aluminum under polyester-based membrane<br />

Surface Hairline finish, 240 grit abrasive grain<br />

Device seal On the enclosure, customized On the front<br />

Special features<br />

Ambient conditions<br />

Decorative membrane drawn across display<br />

Degree of protection IP65 at front; IP20 at rear<br />

Ambient temperature during<br />

operation<br />

0 ... 50 °C<br />

Relative humidity max. 85% (no condensation)<br />

Transport/storage temperature -20 °C to +60 °C<br />

Approvals CE CE, cULus<br />

Sector<br />

HMI software (to be obtained<br />

separately)<br />

Food & beverages, packaging systems, pharmaceuticals<br />

HMI engineering software<br />

Dimensions<br />

From WinCC flexible 2007<br />

Standard with add-on for portrait format<br />

WinCC flexible 2007 Standard and higher<br />

External dimensions<br />

(W x H x D in mm)<br />

229 x 318 As installation cut-out<br />

Installation cutout (W x H x D in mm) 233 x 322 x 67 Compatible with standard device<br />

Special features Rear-mounting panel in portrait format Rear-mounting panel;<br />

panel cutout as on standard device<br />

Weight Approx. 2.7 kg Approx. 5.5 kg<br />

■ Ordering data Order No. ■ More information<br />

MP 377 12" Touch,<br />

rear-mounting<br />

Configuration on request<br />

MP 277 8" Touch vertical,<br />

rear-mounting<br />

With emergency-off button and<br />

3 short-stroke keys with LEDs<br />

on the front<br />

6AV6 644-…<br />

6AV6 643-…<br />

Customized modification options<br />

Customized rear-mounting versions can also be implemented:<br />

Customized operator controls possible on the front,<br />

e.g. membrane keys, emergency-off<br />

Adaptation to the design of the customized enclosure<br />

Customized design (logo and color scheme) on the front<br />

membrane<br />

Configuration on request<br />

Portrait mode of the display<br />

Increased resistance to shock and machine vibration<br />

Quotation preparation<br />

SIMATIC HMI specialists define the product modifications<br />

precisely in accordance with customer requirements.<br />

This is followed by drafting of a quote with:<br />

Non-recurring costs<br />

Prototype costs<br />

Standard unit prices<br />

and the marginal conditions in the form of a product<br />

agreement (e.g. minimum quantity).<br />

The defined device can then be easily ordered using this<br />

product agreement and a customized order number.<br />

6/60<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Overview<br />

Flat Panel 15" Touch INOX, Flat Panel 15" Touch INOX<br />

(enclosed), Flat Panel 19" Touch INOX,<br />

Flat Panel 19" Touch INOX (enclosed)<br />

The Flat Panels with touch screen and stainless steel front are<br />

designed as a display and operating unit for SIMATIC <strong>PC</strong>s in the<br />

food and beverage industry, pharmaceuticals and related industries.<br />

They are easy to clean and can be installed in production areas<br />

subjected to splashes in a suitable control cabinet.<br />

■ Technical specifications<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Customized Automation<br />

Food and beverage industry, pharmaceuticals<br />

■ Design<br />

Flat Panel<br />

General features<br />

15" Touch, INOX 15" Touch INOX<br />

fully enclosed<br />

Flat Panels with stainless steel front<br />

Functions compatible with the<br />

SIMATIC HMI Standard Flat Panels<br />

Enclosure seal EPDM, sulfur-free<br />

Decorative membrane laminated over display,<br />

no display cutout<br />

240 grain brushed stainless steel surface<br />

The Flat Panels 15" Touch INOX and 19" Touch INOX VESA are<br />

fully enclosed and are suitable for space-saving mounting on a<br />

support system. The cables are then placed in the supporting<br />

tube.<br />

19" Touch, INOX 19" Touch INOX<br />

fully enclosed<br />

Power supply 24 V DC 24 V DC 24 V DC 24 V DC<br />

Display 15.1" TFT Touch 15.1" TFT Touch 19.1" TFT Touch 19.1" TFT Touch<br />

Resolution (pixels) 1024 x 768 1024 x 768 12<strong>80</strong> x 1024 12<strong>80</strong> x 1024<br />

MTBF of backlighting (at 25 °C) approx. 50 000 hours CCFL backlighting<br />

Special features Without front USB OSD operation<br />

Without front USB OSD operation<br />

interface<br />

not accessible;<br />

interface<br />

not accessible;<br />

Front<br />

values preset<br />

values preset<br />

Material Stainless steel 1.4301, polyester-based membrane<br />

Surface Hairline finish, 240 grit abrasive grain<br />

Device seal EPDM flat seal EPDM flat seal EPDM flat seal<br />

Special features Decorative membrane drawn across display<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6/61<br />

6


6<br />

Customized Automation<br />

Food and beverage industry, pharmaceuticals<br />

Flat Panels with stainless steel front<br />

■ Technical specifications (continued)<br />

Flat Panel 15" Touch, INOX 15" Touch INOX<br />

fully enclosed<br />

Ambient conditions<br />

Degree of protection On the front: IP66K,<br />

NEMA 4, 4x and 12;<br />

on rear: IP20<br />

Ambient temperature during<br />

operation<br />

■ Ordering data Order No. ■ More information<br />

Flat Panel 15" Touch INOX A 6AV7 486-2TA10-1AA0<br />

Customized modification options<br />

Flat Panel 15" Touch INOX<br />

fully enclosed<br />

6AV7 476-...<br />

Customized design<br />

Customized flange connection<br />

Configuration on request<br />

Cable length up to 30 m<br />

Flat Panel 19" Touch INOX<br />

Cable 1.8 m enclosed<br />

Flat Panel 19" Touch INOX<br />

fully enclosed<br />

A<br />

A<br />

6AV7 486-4TA01-0AA0<br />

6AV7 486-4TA11-0AA0<br />

Drafting a quotation<br />

SIMATIC HMI specialists define the product modifications<br />

precisely in accordance with customer requirements.<br />

Cable 1.8 m pre-assembled<br />

This is followed by drafting a quotation with:<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

Non-recurring costs<br />

Prototype costs<br />

Standard unit prices<br />

and the marginal conditions in the form of a product<br />

agreement (e.g. minimum quantity).<br />

The defined device can then be easily ordered using this<br />

product agreement and a customized Order No.<br />

6/62<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Complete IP65,<br />

NEMA 4<br />

0 ... 50 °C 0 ... +40 °C<br />

at an angle of up to<br />

+/- 20° from the vertical<br />

19" Touch, INOX 19" Touch INOX<br />

fully enclosed<br />

On the front: IP66K,<br />

NEMA 4, 4x and 12;<br />

on rear: IP20<br />

Complete IP66K,<br />

NEMA 4, 4x and<br />

NEMA 12<br />

0 ... 50 °C 0 ... +40 °C<br />

Relative humidity Max. 85% (no condensation)<br />

Transport/storage temperature -20 °C to +60 °C<br />

Approvals CE, cULus CE, cULus CE, cULus CE, cULus<br />

Sector Food & beverages, Pharmaceuticals Food & beverages, Food & beverages,<br />

Dimensions<br />

pharmaceuticals<br />

pharmaceuticals<br />

pharmaceuticals<br />

External dimensions<br />

(W x H x D in mm)<br />

483 x 310 383 x 324 x 72 483 x 400 483 x 399 x 61<br />

Installation cutout (W x H x D in mm) 450 x 296 450 x 3<strong>80</strong><br />

Special features Clamping frame Tiltable customized Clamping frame fully enclosed,<br />

flange for mounting<br />

on control cabinet,<br />

sealed by bellows<br />

VESA 100<br />

Weight Approx. 7 kg Approx. 12 kg Approx. 10 kg Approx. 12 kg


■ Overview<br />

SIMATIC HMI Panels or Panel <strong>PC</strong>s mounted in a stainless steel<br />

cabinet as a ready-to-install and ready-to-use terminal that is<br />

ergonomic and functional, and has a high degree of protection<br />

(complete degree of protection IP66K) as well as tested heat<br />

balance.<br />

The populated and wired turnkey solutions are based on the<br />

hygienic design requirements of the food and beverage industry<br />

as well as other hygiene and wet areas, pharmaceuticals, fine<br />

chemicals and semiconductor production.<br />

■ Design<br />

Control box completely assembled, wired, tested, with<br />

passive cooling<br />

Design of stainless steel terminal<br />

For Panels and Panel <strong>PC</strong>s<br />

Angular surfaces so that liquids can run off<br />

Prepared for stand mounting<br />

With integrated handles at sides.<br />

High complete degree of protection<br />

Screwed-on rear panel<br />

Cable inlet through stand and flange<br />

Simple to clean<br />

No sharp corners or edges<br />

No dead spaces<br />

Hairline finish of surface with 240 grade grain<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Customized Automation<br />

Food and beverage industry, pharmaceuticals<br />

HMI stainless steel operator stations<br />

■ More information<br />

Customized modification options<br />

Other HMI devices, display sizes and resolutions<br />

External stainless steel keyboard, e.g. without short-stroke<br />

keys with piezo technology<br />

Modification of the front/enclosure design<br />

(hygiene test optional) and cable routing<br />

Specific flange from enclosure manufacturers<br />

Breather gland<br />

Use in extended ambient temperature range,<br />

e.g. -20 °C to +60 °C<br />

- Air-water heat exchanger (internal)<br />

- "Temperature Extension Kit" plus active heating and<br />

cooling elements<br />

Certification/approvals<br />

LGA Certificate "Hygiene-tested"<br />

Inspection certificate of the Munich University of Technology<br />

IPA Fraunhofer Institute<br />

These modifications are defined by HMI specialists in consultation<br />

with the customer who then receives a specific offer.<br />

A product agreement with minimum quantities is required for the<br />

implementation of customized modifications. Please contact<br />

your local/national <strong>Siemens</strong> HMI representative.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6/63<br />

6


6<br />

Customized Automation<br />

Oil & gas/chemicals/marine<br />

Oil & gas/chemicals/marine<br />

■ Overview<br />

The requirements of the sectors oil and gas, chemicals and<br />

shipbuilding are diverse and range from use in areas subject to<br />

explosion hazard involving drill pipes, use in the extended<br />

temperature range (outdoor) and in direct sunlight, all the way to<br />

use on the darkened bridge of a ship.<br />

In the case of drill pipes in the oil and gas industry and also in<br />

the chemicals industry, the following product features are<br />

important:<br />

Certification for areas subject to explosion hazard in<br />

Zones 2 and 22 in accordance with ATEX, FM Class I,<br />

Div. 2 and UL Haz. Loc.<br />

Daylight-readable display<br />

Use in sub-zero temperatures and in regions with high<br />

atmospheric humidity<br />

Resistant to harsh environmental conditions<br />

Stainless steel surfaces are demanded for increased<br />

resistance to chemicals<br />

The following features are required in shipbuilding:<br />

Dimmable display down to complete black-out<br />

Marine Type certification such as Germanischer Lloyd<br />

and others<br />

6/64<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

HMI sector products<br />

MP 377 15" Touch daylight readable<br />

TEK – Temperature Extension Kit


■ Overview<br />

Ideal for use in the oil & gas industry:<br />

- Certification in accordance with ATEX for<br />

Zone 2/22, UL Haz. Loc.,<br />

- FM Class I, Div.2<br />

- Bright, daylight-readable display<br />

- Rugged front for harsh environmental conditions<br />

- UV-protected decorative membrane<br />

- High degree of protection<br />

- Can be used in the extended outdoor temperature range at<br />

-30 °C to +70 °C with the TEK option in an air-conditioned<br />

control cabinet<br />

Ideal for use in shipbuilding:<br />

- Diverse shipbuilding certificates (available soon)<br />

- 100% dimmable display backlighting, local and centralized<br />

- Console installation without special measures or restrictions<br />

- High-contrast display with wide reading angle<br />

- Design version with black frame possible<br />

Features:<br />

- Daylight-readable, bright and dimmable LCD display<br />

- Splashwater-protected (IP66)<br />

- Rugged aluminum front, impact-resistant, UV-protected<br />

- Capacitive touch with 3 mm glass for harsh environmental<br />

conditions<br />

- Touch operation with thin gloves<br />

- Outdoor applications with extended temperature range<br />

(option)<br />

- ATEX Zone 2/22, FM Class I, Div. 2, UL Haz. Loc.<br />

- Marine certificates:<br />

DNV, GL, NK, ABS, LRS, CCS, RINA<br />

-Fan-free<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Customized Automation<br />

Oil & gas/chemicals/marine<br />

MP 377 15" Touch daylight readable<br />

A panel for applications inside and outside the production hall<br />

Extremely easy to read under diverse conditions<br />

Ergonomic dimmer function for optimal reading in control<br />

desks<br />

Can be connected to centralized dimming potentiometer<br />

(via PLC)<br />

Familiar HMI functions (exception: Sm@rt option and highspeed<br />

keys), no new training<br />

Can also be used in the extended temperature ranges with the<br />

TEK Temperature Extension Kit option<br />

■ Application<br />

The Panel has a daylight-readable and dimmable display,<br />

making it predestined for use in control desks for, e.g. drill<br />

strings (oil & gas industry), ships (shipbuilding) and other<br />

exposed areas up to outdoor applications with the<br />

TEK Temperature Extension Kit option.<br />

■ Design<br />

The "MP 377 15" Touch daylight readable" has a powder-coated<br />

milled aluminum front that is impact-resistant, scratch-proof and<br />

highly resistant to chemicals.<br />

Touch operation uses projected capacitive technology<br />

protected against humidity, heat and dirt in harsh environments<br />

by a 3-mm pane of glass, without reflective membranes.<br />

The refined polyester-based decorative membrane is<br />

UV-resistant and protected against yellowing and embrittling.<br />

The LED-backlit and dimmable display is designed using transflective<br />

technology that allows a higher contrast than conventional,<br />

transmissive displays in extremely bright environments.<br />

The LED backlighting is dimmable using a slider on the process<br />

picture or centrally via the controller. Dimming is carried out<br />

using a gradation curve and is thus optimally ergonomically<br />

matched to the human eye.<br />

The Panel is based on the field-proven electronic card of the<br />

MP 377 with WinCC flexible functionality and the familiar interfaces.<br />

The entire mechanical design is prepared for good<br />

convection and temperature balance, for long service life, and<br />

for operation onboard ship, or other vehicles with corresponding<br />

shock and vibration stresses.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6/65<br />

6


6<br />

Customized Automation<br />

Oil & gas/chemicals/marine<br />

MP 377 15" Touch daylight readable<br />

■ Technical specifications ■ Ordering data Order No.<br />

Multi Panels<br />

General features<br />

MP 377 15" Touch<br />

daylight readable<br />

Display 15" TFT, transflective<br />

Brightness typ. <strong>80</strong>0 cd/m2 Contrast typ. 1000:1<br />

Reading angle 160°<br />

Resolution 1024 x 768<br />

MTBF of backlit display (at 25°C) 50,000 hrs LED backlighting,<br />

dimmable 0 (off) to 100%<br />

Input unit Touch, projected capacitive<br />

Power supply 24 V DC, typ. 1.5 A<br />

Special features<br />

Front<br />

Daylight-readable<br />

Material Aluminum, Autotex XE, glass<br />

Surface Powder-coated aluminum,<br />

polyester-based decorative<br />

membrane, glass (Mohs 7)<br />

Device seal<br />

Ambient conditions<br />

HC / EPDM 4x4<br />

Degree of protection Front IP66, rear IP20<br />

Ambient temperature during<br />

operation<br />

6/66<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Front -30 °C to +70 °C,<br />

rear 0 °C to +50 °C,<br />

changeover time >= 3 min.<br />

Relative humidity 10% to 90%,<br />

without condensation<br />

Vibration IEC 60068, Part 2–6 (sine),<br />

constant acceleration 1 g<br />

Shock IEC 60068, Part 2–29,<br />

15 g peak value, 11 ms duration<br />

Transport and storage conditions IEC 60721-3-2, Class 2M2<br />

Transport/storage temperature -40 °C to +<strong>80</strong> °C<br />

Approvals CE, cULus, C-Tick,<br />

ATEX Zone 2/22, UL haz. loc.,<br />

FM Class I, Div. 2, shipbuilding<br />

certificates available soon<br />

Sector Oil & gas, ship, outdoor<br />

Can be connected to SIMATIC <strong>PC</strong> Multi Panels<br />

HMI software<br />

HMI engineering software Configurable from<br />

WinCC flexible 2008,<br />

SP1 with add-ons<br />

HMI Runtime software<br />

Special features Console mounting with an<br />

inclination of up to 90°,<br />

installation cutout as on<br />

MP 377 15" Touch (W x H)<br />

Dimensions<br />

External dimensions<br />

400 x 315.5 x 106<br />

(W x H x D in mm)<br />

Installation cutout<br />

365.6 x 287 x 100<br />

(W x H x D in mm)<br />

Weight 4.6 kg<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

MP 377 15" Touch<br />

daylight readable<br />

Multi Panel 15" Touch with display<br />

suitable for natural-light viewing<br />

E 6AV6 644-8AB20-0AA1<br />

E: Subject to export regulations: AL: 9I999 and ECCN: 5D002ENCU<br />

■ More information<br />

Customized modification options<br />

Integration into customized turnkey operator panels<br />

Customized design<br />

Drafting a quotation<br />

SIMATIC HMI specialists define the product modifications<br />

precisely in accordance with customer requirements.<br />

This is followed by drafting a quotation with:<br />

Non-recurring costs<br />

Prototype costs<br />

Standard unit prices<br />

and the marginal conditions in the form of a product<br />

agreement (e.g. minimum quantity).<br />

The defined device can then be easily ordered using this<br />

product agreement and a customized Order No.


■ Overview<br />

TEK – front view<br />

TEK – side view<br />

TEK Temperature Extension Kit<br />

for MP 377 15" Touch daylight readable<br />

The TEK (Temperature Extension Kit) is a sector-specific<br />

supplement for the MP 377 15" Touch daylight readable operator<br />

panel and is used for the extended temperature range from<br />

-20 °C to +55 °C and an atmospheric humidity greater than 90%.<br />

Permissible ambient temperature in operation is otherwise<br />

0 to 50 °C and 90% relative humidity (without condensation).<br />

The TEK comprises the following components:<br />

Climate controller with integrated humidity sensor<br />

Set with temperature sensors<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Benefits<br />

Customized Automation<br />

Oil & gas/chemicals/marine<br />

TEK – Temperature Extension Kit<br />

The TEK enables device applications in environments that were<br />

previously not available for the unprotected electronic device<br />

(e.g. operator panel Microbox <strong>PC</strong>) due to impermissible ambient<br />

conditions.<br />

Fastest-possible, automatic power-up of the operator panel after<br />

connection of the supply voltage and establishment of the<br />

operating conditions by the TEK.<br />

The TEK optimizes use of the connected fan, and the heating<br />

and cooling systems:<br />

Energy-efficient thanks to utilization of the specific limits of the<br />

electronic device<br />

Avoidance of corrosion by regulating the atmospheric<br />

humidity<br />

Optimization of the control and adaptation to different<br />

disturbance variables by<br />

- taking account of the temperature gradients<br />

- taking account of the temperature difference on the<br />

electronic device and the surface temperature of the<br />

enclosure<br />

■ Application<br />

The relevant ambient conditions are predominantly in the<br />

outdoor area of the oil & gas industry, the chemicals industry and<br />

in refrigeration rooms in the food and beverage industry or<br />

related areas. The extended temperature range is characteristic<br />

of these areas.<br />

■ Design<br />

The TEK comprises the following components:<br />

Climate controller with integrated humidity sensor<br />

Set with temperature sensors<br />

Product features of the Temperature Extension Kit<br />

The TEK is installed in an enclosure together with an operator<br />

panel and supplementary, active components for air<br />

conditioning. Active components, such as heating/cooling<br />

systems and air circulating fans, are necessary for the overall<br />

function. You will find information on their dimensioning in the<br />

operating instructions of the TEK, or you can consult an<br />

experienced control cabinet builder.<br />

The climate controller has temperature-toughened modules<br />

that are also ice-proof and condensation-proof to deal with the<br />

relevant environmental influences.<br />

The climate controller establishes the climatic conditions for<br />

operation in the enclosure (control box, control cabinet) even<br />

if the permissible ambient conditions for the electronic device<br />

are not maintained outside the enclosure.<br />

The climate controller has two operating modes:<br />

- In automatic mode ("Auto-ON"), the climate controller<br />

switches the operator panel on automatically and as quickly<br />

as possible as soon as the climatic conditions inside the<br />

electronic control box are within the tolerance range.<br />

- In manual mode ("Manual-ON"), the user can switch the<br />

operator panel on using a pushbutton as soon as the climatic<br />

conditions are within the tolerance range.<br />

If the user presses the button before the climatic conditions<br />

have been established, the climate controller saves this<br />

switch-on request and switches the operator panel on as<br />

soon as the climatic conditions are within the tolerance<br />

range.<br />

When the operator panel has been switched on, it remains<br />

switched on.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

6/67<br />

6


6<br />

Customized Automation<br />

Oil & gas/chemicals/marine<br />

TEK – Temperature Extension Kit<br />

■ Design (continued)<br />

■ Ordering data Order No.<br />

Use in areas subject to explosion hazard<br />

TEK –<br />

A 6AV6 675-5XA01-0AX0<br />

Additional measures, such as the use of a suitable control<br />

Temperature Extension Kit<br />

cabinet, are required for use of the TEK in areas subject to Consisting of:<br />

explosion hazard in Zones 2 or 22 corresponding to the ATEX TEK climate controller module<br />

product guideline or for Class I, Div. 2 applications. The relevant,<br />

special installation guidelines in areas subject to explosion<br />

Accessories pack with<br />

3 x Pt100 sensors and<br />

hazard must be adhered to.<br />

mounting clips<br />

■ Function<br />

TEK climate controller<br />

As separate part<br />

A 6AV6 675-5XA00-0AX0<br />

The Climate Controller determines the climatic conditions in<br />

the enclosure using the temperature sensors and the<br />

integrated humidity sensor.<br />

TEK accessories pack<br />

Operating Instructions<br />

A 6AV6 675-5XB00-0AX0<br />

as download<br />

The Climate Controller indicates whether the climatic<br />

conditions in the enclosure are within the preselected<br />

tolerance range or not and thus warns against potential<br />

damage to the operator panel.<br />

in German/English http://<br />

support.automation.siemens.com<br />

/WW/<br />

llisapi.dll?func=cslib.csinfo&objId<br />

=39848694&objAction=csOpen&<br />

Depending on requirements, the climate controller activates<br />

the fan and heater or refrigerator to establish the climatic<br />

conditions for operation of the operator panel within the<br />

nodeid0=10<strong>80</strong>5608&lang=de&sit<br />

eid=csius&aktprim=0&extranet=s<br />

tandard&viewreg=WW<br />

control cabinet.<br />

The heater and refrigerator are controlled via an optimized<br />

A: Subject to export regulations: AL: N and ECCN: EAR99H<br />

two-position controller, taking account of the temperature<br />

gradients and the relative atmospheric humidity. The fan is ■ More information<br />

controlled taking account of the temperature difference at the<br />

device.<br />

The Climate Controller indicates whether the operator panel is<br />

switched on or not and whether the control is active or not.<br />

Customized modification options<br />

Dimensioning and production of a turnkey operator station for<br />

customized ambient conditions<br />

■ Technical specifications<br />

Quotation preparation<br />

SIMATIC HMI specialists define the product modifications<br />

Technical data TEK climate controller<br />

precisely in accordance with customer requirements.<br />

Storage temperature -40 °C to +<strong>80</strong> °C;<br />

This is followed by drafting of a quote with:<br />

control range<br />

(outdoor temperature):<br />

-20 °C to +50 °C<br />

Non-recurring costs<br />

Prototype costs<br />

Interfaces 3 x Pt100<br />

Standard unit prices<br />

1 integral humidity sensor<br />

2 x DI for keys<br />

3 x DO for signal lamps<br />

and the marginal conditions in the form of a product<br />

agreement (e.g. minimum quantity).<br />

5 x floating contacts for active<br />

components<br />

2 rotary switches for<br />

parameterization<br />

The defined device can then be easily ordered using this<br />

product agreement and a customized order number.<br />

Mounting on DIN rail<br />

Degree of protection IP20, protected against brief<br />

condensation<br />

Current consumption, typical 400 mA (24 V DC)<br />

Certification<br />

Ambient temperature<br />

CE, cULus, C-Tick<br />

During operation 0 °C to +50 °C<br />

Relative humidity 10% to 90% without condensation<br />

Transport/storage temperature -40 °C to +<strong>80</strong> °C<br />

Vibration 1 g (IEC 60068, Part 2-6)<br />

Shock<br />

Dimensions<br />

15 g (11 ms, IEC 60068,<br />

Part 2-29)<br />

Mounting dimensions WxHxD (mm) 120.5 x 96 x 61.3<br />

Weight 200 g<br />

6/68<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


Appendix<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

7/2 Training<br />

7/3 Course overview<br />

7/4 Standards and approvals<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

7<br />

7/5 Partner at Industry Automation<br />

and Drive Technologies<br />

7/5 <strong>Siemens</strong> contacts worldwide<br />

7/5 WinCC Competence Centers<br />

7/7 <strong>Siemens</strong> Solution Partner<br />

7/8 Online Services<br />

7/8 Information and Ordering<br />

in the Internet and on DVD<br />

7/9 Service & Support<br />

7/9 The unmatched complete service<br />

for the entire life cycle<br />

7/11 Knowledge Base on DVD<br />

7/11 Automation Value Card<br />

7/12 <strong>Siemens</strong> Service Option for<br />

SIMATIC <strong>PC</strong> / PG<br />

7/13 Expertise and services relating to all<br />

aspects of <strong>PC</strong>-based Automation<br />

7/14 Software Licenses<br />

7/15 Index<br />

7/18 Order No. Index<br />

7/20 Length key for connecting cables<br />

7/21 <strong>Catalog</strong> improvement suggestions<br />

7/23 Conditions of sale and delivery,<br />

Export regulations


7<br />

Appendix<br />

Training<br />

■ Faster and more applicable know-how:<br />

Hands-on training from the manufacturer<br />

SITRAIN ® ■ SITRAIN highlights<br />

Top trainers<br />

– the <strong>Siemens</strong> Training for Automation and Industrial<br />

Solutions – provides you with comprehensive support in solving<br />

Our trainers are skilled teachers with direct practical experience.<br />

your tasks.<br />

Course developers have close contact with product development,<br />

and directly pass on their knowledge to the trainers.<br />

Training by the market leader in automation and plant engineering<br />

enables you to make independent decisions with confi- Practical experience<br />

dence. Especially where the optimum and efficient use of prod- The practical experience of our trainers enables them to teach<br />

ucts and plants are concerned. You can eliminate deficiencies in theory effectively. But since theory can be pretty drab, we attach<br />

existing plants, and exclude expensive faulty planning right from great importance to practical exercises which can comprise up<br />

the beginning.<br />

to half of of the course time. You can therefore immediately implement<br />

your new knowledge in practice. We train you on stateof-the-art<br />

methodically/didactically designed training equipment.<br />

This training approach will give you all the confidence you<br />

need.<br />

Wide variety<br />

With a total of about 300 local attendance courses, we train the<br />

complete range of <strong>Siemens</strong> Industry products as well as interaction<br />

of the products in systems.<br />

Tailor-made training<br />

We are only a short distance away. You can find us at more than<br />

50 locations in Germany, and in 62 countries worldwide. You<br />

wish to have individual training instead of one of our<br />

300 courses? Our solution: We will provide a program tailored<br />

exactly to your personal requirements. Training can be carried<br />

out in our Training Centers or at your company.<br />

The right mixture: Blended learning<br />

First-class know-how directly pays for itself: In shorter startup<br />

"Blended learning" means a combination of various training me-<br />

times, high-quality end products, faster troubleshooting and redia<br />

and sequences. For example, a local attendance course in<br />

duced downtimes. In other words, increased profits and lower<br />

a Training Center can be optimally supplemented by a teach-<br />

costs.<br />

yourself program as preparation or follow-up. Additional effect:<br />

Reduced traveling costs and periods of absence.<br />

Achieve more with SITRAIN<br />

Shorter times for startup, maintenance and servicing<br />

Optimized production operations<br />

Reliable configuration and startup<br />

Minimization of plant downtimes<br />

Flexible plant adaptation to market requirements<br />

Compliance with quality standards in production<br />

Increased employee satisfaction and motivation<br />

Shorter familiarization times following changes in technology<br />

and staff<br />

■ Contact<br />

Visit our site on the Internet at:<br />

www.siemens.com/sitrain<br />

or let us advise you personally.<br />

SITRAIN Customer Support Germany:<br />

Phone: +49 (0) 911 / 895 7575<br />

Fax: +49 (0) 911 / 895 7576<br />

E-Mail: info@sitrain.com<br />

7/2<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Training offer for SIMATIC HMI and <strong>PC</strong>-based Automation<br />

This page contains an overview of the SITRAIN training offer for<br />

SIMATIC HMI operator control and monitoring systems as well as<br />

for <strong>PC</strong>-based Automation.<br />

Depending on your demands we’ll make you fit for specific applications<br />

or teach you important background knowledge about<br />

products and systems.<br />

All courses contain the largest possible share of practical exercises<br />

so that training can be carried out very intensively in very<br />

small groups.<br />

Further information regarding course contents, dates and prices<br />

can be found in the Internet at:<br />

www.siemens.com/sitrain<br />

■ SITRAIN courses for SIMATIC HMI / <strong>PC</strong>-based Automation<br />

■ SIMATIC WinCC based on TIA Portal<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Commissioning engineers,<br />

configuration engineers<br />

Programmers Service personnel<br />

Project managers, project team members Operators, users<br />

Decision makers, sales personnel Maintenance personnel<br />

Title Target Group Duration/<br />

Medium<br />

Appendix<br />

Training<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Course overview<br />

Short title<br />

SIMATIC TIA Portal WinCC SCADA retraining course ✔ ✔ ✔ ✔ ✔ 3 days TIA-WCCSUP<br />

SIMATIC TIA Portal WinCC on the machine level ✔ ✔ ✔ ✔ ✔ 3 days TIA-WCCM<br />

SIMATIC TIA Portal WinCC SCADA ✔ ✔ ✔ ✔ ✔ 5 days TIA-WCCS<br />

SIMATIC TIA Portal WinCC on the machine level (expected summer <strong>2011</strong>) ✔ ✔ ✔ ✔ ✔ WBT WT-TIAWMUP<br />

■ SIMATIC WinCC flexible<br />

SIMATIC WinCC flexible, system course 1 ✔ ✔ ✔ ✔ ✔ 3 days <strong>ST</strong>-WCCFSYS1<br />

SIMATIC WinCC flexible, system course 2 ✔ ✔ ✔ ✔ 3 days <strong>ST</strong>-WCCFSY2<br />

■ SIMATIC WinCC based on V6.x or V7.x<br />

SIMATIC WinCC, System Course ✔ ✔ ✔ ✔ ✔ 5 days <strong>ST</strong>-BWINCCS<br />

SIMATIC WinCC, Advanced configuration, Options for networking and<br />

access to Database<br />

■ SIMATIC WinCC V7.x Market-specific Solutions<br />

✔ ✔ 5 days <strong>ST</strong>-BWINOND<br />

Energy Management<br />

Energy management with SIMATIC powerrate for WinCC ✔ ✔ ✔ ✔ ✔ 3 days <strong>ST</strong>-EMPRWCC<br />

Energy management with B.Data ✔ ✔ ✔ ✔ ✔ 4 days <strong>ST</strong>-EMBDATA<br />

Energy management with SIMATIC powerrate for <strong>PC</strong>S 7 ✔ ✔ ✔ ✔ ✔ 3 days <strong>ST</strong>-EMPR<strong>PC</strong>S<br />

These courses are based on the new engineering platform TIA Portal.<br />

7/3<br />

7


7<br />

Appendix<br />

Standards and approvals<br />

■ Operating system licenses for SIMATIC <strong>PC</strong>/PG ■ CE marking<br />

The accompanying operating system license is only valid for The electronic products described in this catalog fulfill the<br />

installation on the supplied SIMATIC <strong>PC</strong>/PG.<br />

requirements and safety objectives of the following<br />

EC Directives and comply with the harmonized European<br />

Installation can only be performed on these SIMATIC systems in<br />

standards (EN) published for programmable logic controllers in<br />

accordance with Microsoft OEM licensing regulations.<br />

the official journals of the European Community:<br />

89/336/EEC "Electromagnetic Compatibility"<br />

■ Standards UL (U) and CSA (C)<br />

(EMC directive)<br />

All HMI products comply with the standards UL (U) and CSA (C), 73/23/EEC Low Voltage Directive (for electrical equipment)<br />

or the approval procedure has been applied for.<br />

The EC declarations of conformity are available for the relevant<br />

Products which have no approval are specially marked<br />

authorities at the following address:<br />

(see ordering data of the products).<br />

SIMATIC HMI:<br />

<strong>Siemens</strong> AG<br />

I IA AS SM ID<br />

P.O. Box 48 48<br />

90327 Nuremberg, Germany<br />

SIMATIC, SIMATIC NET, SIMATIC <strong>PC</strong>:<br />

<strong>Siemens</strong> AG<br />

IA AS EWA<br />

P.O. Box 19 63<br />

92209 Amberg, Germany<br />

7/4<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong>


■ Overview<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Appendix<br />

Partner at Industry Automation and Drive Technologies<br />

<strong>Siemens</strong> contacts worldwide<br />

At <strong>Siemens</strong> Industry Automation and Drive Technologies, more<br />

than 85 000 people are resolutely pursuing the same goal: longterm<br />

improvement of your competitive ability. We are committed<br />

to this goal. Thanks to our commitment, we continue to set new<br />

standards in automation and drive technology. In all industries –<br />

worldwide.<br />

At your service locally, around the globe for consulting, sales,<br />

training, service, support, spare parts ... on the entire Industry<br />

Automation and Drive Technologies range.<br />

Your personal contact can be found in our Contacts Database at:<br />

www.siemens.com/automation/partner<br />

You start by selecting a<br />

Product group,<br />

Country,<br />

City,<br />

Service.<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

7/5<br />

7


7<br />

Appendix<br />

WinCC Competence Centers<br />

■ WinCC Competence Centers<br />

The WinCC Competence Centers are <strong>Siemens</strong>-internal partners.<br />

They offer a wide range of products and services designed to<br />

make optimal economic and system-oriented use of the openness<br />

and integration capability of WinCC.<br />

In addition to the development of standard solutions/add-on<br />

products, they are authorized to implement customized/<br />

industry-specific solutions in the areas of application development<br />

and system integration on the basis of WinCC. The portfolio<br />

is rounded off with consulting services, project-related training,<br />

and workshops for decision-makers and users.<br />

Sector competence in addition to automation expertise and<br />

WinCC system know-how ensure professional and efficient solutions.<br />

The software is, of course, developed in compliance with<br />

recognized standards on the basis of certified quality management<br />

in accordance with DIN ISO 9001.<br />

7/6<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

You can find more information on the Internet at:<br />

www.siemens.com/wincc-competence-center


■ Overview<br />

<strong>Siemens</strong> Solution Partner Automation<br />

The products and systems from <strong>Siemens</strong> Industry Automation<br />

and Drive Technologies offer the ideal platform for all automation<br />

applications.<br />

Under the name of <strong>Siemens</strong> Solution Partners, selected system<br />

integrators around the world act as uniformly qualified solution<br />

providers for the <strong>Siemens</strong> range of products and services in the<br />

fields of automation and drives. Day after day, they utilize their<br />

qualified product and system know-how as well as their<br />

excellent industry expertise to your advantage – for all requirements.<br />

The partner emblem is the guarantee and indicator of proven<br />

quality. The basis for this are defined quality features that identify<br />

Solution Partners as reliable and competent solution providers:<br />

Solution quality<br />

Always a good result with tried and tested solution know-how.<br />

Expert quality<br />

Certified technical competence ensures maximum efficiency.<br />

Project quality<br />

With proven project experience straight to the target.<br />

Offer quality<br />

Comprehensive portfolio for state-of-the-art solutions from a<br />

single source.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Appendix<br />

Partner at Industry Automation and Drive Technologies<br />

<strong>Siemens</strong> Solution Partner<br />

Solution Partner Finder<br />

The <strong>Siemens</strong> Solution Partner Program helps you to find the<br />

optimum partner for your specific requirements. Support is<br />

provided by the Solution Partner Finder, a comprehensive online<br />

database that showcases the profiles of all our solution partners.<br />

You can convince yourself of the competence of the respective<br />

Solution Partner by means of the references provided.<br />

The following search criteria are possible:<br />

Country<br />

Technology<br />

Sector<br />

Company<br />

Zip code<br />

Once you have located a partner, you are only one small step<br />

from contacting them.<br />

You can locate the Solution Partner Finder as follows:<br />

www.siemens.com/automation/partnerfinder<br />

Additional information on the <strong>Siemens</strong> Solution Partner Program<br />

is available online at:<br />

www.siemens.com/automation/solutionpartner<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

7/7<br />

7


7<br />

Appendix<br />

Online Services<br />

Information and Ordering<br />

in the Internet and on DVD<br />

■ <strong>Siemens</strong> Industry Automation and Drive Technologies in the WWW<br />

A detailed knowledge of the range of products and services<br />

available is essential when planning and configuring automation<br />

systems. It goes without saying that this information must always<br />

be fully up-to-date.<br />

<strong>Siemens</strong> Industry Automation and Drive Technologies has<br />

therefore built up a comprehensive range of information in the<br />

World Wide Web, which offers quick and easy access to all data<br />

required.<br />

Under the address<br />

www.siemens.com/industry<br />

you will find everything you need to know about products, systems<br />

and services.<br />

■ Product Selection Using the Interactive <strong>Catalog</strong> CA 01 of Industry<br />

Detailed information together with convenient interactive<br />

functions:<br />

The interactive catalog CA 01 covers more than <strong>80</strong> 000 products<br />

and thus provides a full summary of the <strong>Siemens</strong> Industry Automation<br />

and Drive Technologies product base.<br />

Here you will find everything that you need to solve tasks in the<br />

fields of automation, switchgear, installation and drives.<br />

All information is linked into a user interface which is easy to<br />

work with and intuitive.<br />

After selecting the product of your choice you can order at the<br />

press of a button, by fax or by online link.<br />

Information on the interactive catalog CA 01 can be found in the<br />

Internet under<br />

www.siemens.com/automation/ca01<br />

or on DVD.<br />

■ Easy Shopping with the Industry Mall<br />

7/8<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

The Industry Mall is the virtual department store of <strong>Siemens</strong> AG<br />

in the Internet. Here you have access to a huge range of products<br />

presented in electronic catalogs in an informative and attractive<br />

way.<br />

Data transfer via EDIFACT allows the whole procedure from<br />

selection through ordering to tracking of the order to be carried<br />

out online via the Internet.<br />

Numerous functions are available to support you.<br />

For example, powerful search functions make it easy to find the<br />

required products, which can be immediately checked for availability.<br />

Customer-specific discounts and preparation of quotes<br />

can be carried out online as well as order tracking and tracing.<br />

Please visit the Industry Mall on the Internet under:<br />

www.siemens.com/industrymall


For machine constructors, solution providers and plant operators:<br />

The service offering from <strong>Siemens</strong> Industry, Automation and<br />

Drive Technologies includes comprehensive services for a wide<br />

range of different users in all sectors of the manufacturing and<br />

process industry<br />

To accompany our products and systems, we offer integrated<br />

and structured services that provide valuable support in every<br />

phase of the life cycle of your machine or plant - from planning<br />

and implementation through commissioning as far as maintenance<br />

and modernization.<br />

■ Online Support<br />

■ Technical Support<br />

Service Service<br />

Programs Programs<br />

Technical<br />

Consulting<br />

Field Field<br />

Service Service<br />

Modernization<br />

Modernization<br />

Services Services<br />

■ Technical Consulting<br />

The comprehensive online information<br />

platform supports you in<br />

all aspects of our Service & Support<br />

at any time and from any location<br />

in the world.<br />

www.siemens.com/<br />

automation/service&support<br />

Expert advice on technical<br />

questions with a wide range of<br />

demand-optimized services for<br />

all our products and systems.<br />

www.siemens.com/<br />

automation/support-request<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Online Online Support Support<br />

Technical Technical<br />

Support Support<br />

Appendix<br />

Service & Support<br />

The unmatched complete service<br />

for the entire life cycle<br />

Our Service & Support accompanies you worldwide in all matters<br />

concerning automation and drives from <strong>Siemens</strong>. We provide<br />

direct on-site support in more than 100 countries through all<br />

phases of the life cycle of your machines and plants.<br />

You have an experienced team of specialists at your side to provide<br />

active support and bundled know-how. Regular training<br />

courses and intensive contact among our employees - even<br />

across continents - ensure reliable service in the most diverse<br />

areas.<br />

■ Training<br />

Training Training<br />

Spare Spare Parts Parts<br />

Optimization<br />

Optimization<br />

Services Services<br />

Engineering<br />

Support<br />

Support in planning and designing<br />

your project: From detailed<br />

actual-state analysis, definition<br />

of the goal and consulting on<br />

product and system questions<br />

right through to the creation of<br />

the automation solution.<br />

Extend your competitive edge -<br />

through practical know-how<br />

directly from the manufacturer.<br />

www.siemens.com/sitrain<br />

Contact information is available in the Internet at:<br />

www.siemens.com/automation/partner<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

7/9<br />

7


7<br />

Appendix<br />

Service & Support<br />

The unmatched complete service<br />

for the entire life cycle<br />

■ Engineering Support<br />

■ Field Service<br />

■ Spare parts<br />

■ Repairs<br />

■ Optimization<br />

7/10<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

Support during project engineering<br />

and development with<br />

services fine-tuned to your requirements,<br />

from configuration<br />

through to implementation of an<br />

automation project.<br />

Our Field Service offers you services<br />

for commissioning and<br />

maintenance - to ensure that<br />

your machines and plants are<br />

always available.<br />

In every sector worldwide,<br />

plants and systems are required<br />

to operate with constantly increasing<br />

reliability. We will provide<br />

you with the support you<br />

need to prevent a standstill from<br />

occurring in the first place: with<br />

a worldwide network and optimum<br />

logistics chains.<br />

Downtimes cause problems in<br />

the plant as well as unnecessary<br />

costs. We can help you to reduce<br />

both to a minimum - with<br />

our worldwide repair facilities.<br />

During the service life of machines<br />

and plants, there is often<br />

a great potential for increasing<br />

productivity or reducing costs.<br />

To help you achieve this potential,<br />

we are offering a complete<br />

range of optimization services.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Modernization<br />

■ Service programs<br />

You can also rely on our support<br />

when it comes to modernization<br />

- with comprehensive services<br />

from the planning phase all the<br />

way to commissioning.<br />

Our service programs are selected<br />

service packages for an<br />

automation and drives system or<br />

product group. The individual<br />

services are coordinated with<br />

each over to ensure smooth<br />

coverage of the entire life cycle<br />

and support optimum use of<br />

your products and systems.<br />

The services of a Service Program<br />

can be flexibly adapted at<br />

any time and used separately.<br />

Examples of service programs:<br />

7 Service contracts<br />

7 Plant IT Security Services<br />

7 Life Cycle Services for Drive Engineering<br />

7 SIMATIC <strong>PC</strong>S 7 Life Cycle Services<br />

7 SINUMERIK Manufacturing Excellence<br />

7 SIMATIC Remote Support Servicess<br />

Advantages at a glance:<br />

7 Reduced downtimes for increased productivity<br />

7 Optimized maintenance costs due to a tailored scope of services<br />

7 Costs that can be calculated and therefore planned<br />

7 Service reliability due to guaranteed response times and<br />

spare part delivery times<br />

7 Customer service personnel will be supported and relieved of<br />

additional tasks<br />

7 Comprehensive service from a single source, fewer interfaces<br />

and greater expertise<br />

Contact information is available in the Internet at:<br />

www.siemens.com/automation/partner


■ Knowledge Base on DVD<br />

■ Automation Value Card<br />

For locations without online connections<br />

to the Internet there are<br />

excerpts of the free part of the<br />

information sources available on<br />

DVD (Service & Support Knowledge<br />

Base). This DVD contains<br />

all the latest product information<br />

at the time of production (FAQs,<br />

Downloads, Tips and Tricks, Updates)<br />

as well as general information<br />

on Service & Support.<br />

Small card - great support<br />

The Automation Value Card is an integral component of the comprehensive<br />

service concept with which <strong>Siemens</strong> Automation and<br />

Drives will accompany you in each phase of your automation<br />

project.<br />

It doesn't matter whether you want just specific services from our<br />

Technical Support or want to purchase something on our Online<br />

portal, you can always pay with your Automation Value Card. No<br />

invoicing, transparent and safe. With your personal card number<br />

and associated PIN you can view the state of your account and<br />

all transactions at any time.<br />

Services on card. This is how it's done.<br />

Card number and PIN are on the back of the Automation Value<br />

Card. When delivered, the PIN is covered by a scratch field,<br />

guaranteeing that the full credit is on the card.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Appendix<br />

Service & Support<br />

Knowledge Base on DVD<br />

Automation Value Card<br />

The DVD also includes a full-text search and our Knowledge<br />

Manager for targeted searches for solutions. The DVD will be updated<br />

every 4 months.<br />

Just the same as our online offer in the Internet, the Service &<br />

Support Knowledge Base on DVD comes complete in 5 languages<br />

(German, English, French, Italian, Spanish).<br />

You can order the Service & Support Knowledge Base DVD<br />

from your <strong>Siemens</strong> contact.<br />

Order no. 6ZB5310-0EP30-0BA2<br />

By entering the card number and PIN you have full access to the<br />

Service & Support services being offered. The charge for the<br />

services procured is debited from the credits on your Automation<br />

Value Card.<br />

All the services offered are marked in currency-neutral credits,<br />

so you can use the Automation Value Card worldwide.<br />

Order your Automation and Value Card easily and comfortably<br />

like a product with your sales contact.<br />

Automation Value Card order numbers<br />

Credits Order no.<br />

200 6ES7 997-0BA00-0XA0<br />

500 6ES7 997-0BB00-0XA0<br />

1000 6ES7 997-0BC00-0XA0<br />

10 000 6ES7 997-0BG00-0XA0<br />

Detailed information on the services offered is available on our<br />

Internet site at:<br />

www.siemens.com/automation/service&support<br />

Service & Support à la Card: Examples<br />

Technical Support<br />

”Priority“ Priority processing for urgent cases<br />

”24 h“ Availability round the clock<br />

”Extended“ Technical consulting for complex questions<br />

”Mature Consulting service for products that are not available<br />

Products“ any more<br />

Support Tools in the Support Shop<br />

Tools that can be used directly for configuration, analysis<br />

and testing<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

7/11<br />

7


7<br />

Appendix<br />

Service & Support<br />

<strong>Siemens</strong> Service Option for SIMATIC <strong>PC</strong> / PG<br />

■ <strong>Siemens</strong> Service Option for SIMATIC <strong>PC</strong> / PG<br />

The expanded hardware service for SIMATIC <strong>PC</strong>/PG<br />

products<br />

Purchasing and registering this additional agreement for a<br />

SIMATIC <strong>PC</strong>/PG extends the time period for free repairs of this<br />

device to 36 months after delivery.<br />

Scope of services of the service option within the period of<br />

service (36 months):<br />

Free 1) repair during the period of service at one of our<br />

authorized repair centers near you<br />

The addresses of our worldwide partners can be found on the<br />

Internet at www.siemens.com/asis<br />

Within the agreed contractual period, <strong>Siemens</strong> will bear the<br />

costs that are incurred in the repair center (labor and<br />

materials/replacement parts), which are needed to restore the<br />

functions 2) of the hardware<br />

<strong>Siemens</strong> will also assume the return shipping costs of the<br />

repaired device from the repair center to the customer<br />

1) Wear and tear as well as problems that arise due to improper handling of<br />

the devices are not included.<br />

2) For hard disk defects that require the system to be restored, the repair<br />

service will only cover restoring the installation to its original condition<br />

ex works.<br />

The uploading of additional application software, drivers and setting up the<br />

operating software are not covered by the free repair service.<br />

7/12<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Product family Order No.<br />

Service Option<br />

Order designation<br />

SIMATIC Rack <strong>PC</strong> A5E00510072 36 months service<br />

SIMATIC I<strong>PC</strong>547<br />

SIMATIC I<strong>PC</strong>647<br />

SIMATIC I<strong>PC</strong>847<br />

SIMATIC Rack <strong>PC</strong> 647B<br />

SIMATIC Box <strong>PC</strong><br />

SIMATIC I<strong>PC</strong>227<br />

SIMATIC I<strong>PC</strong>427<br />

SIMATIC I<strong>PC</strong>627<br />

SIMATIC I<strong>PC</strong>827<br />

SIMATIC Box <strong>PC</strong> 827B<br />

option for SIMATIC<br />

Rack <strong>PC</strong> and Box <strong>PC</strong><br />

SIMATIC Panel <strong>PC</strong> A5E00509961 36 months service<br />

SIMATIC HMI I<strong>PC</strong>277<br />

SIMATIC HMI I<strong>PC</strong>477<br />

SIMATIC HMI I<strong>PC</strong>577<br />

SIMATIC HMI I<strong>PC</strong>677<br />

SIMATIC Panel <strong>PC</strong> 677B<br />

option for SIMATIC<br />

Panel <strong>PC</strong>s<br />

SIMATIC Field PG A5E00510007 36 months service<br />

SIMATIC Field PG M2<br />

SIMATIC Field PG M3<br />

option for SIMATIC<br />

Field PG M2/M3<br />

Ordering and registering the additional agreement:<br />

Select the appropriate order number for the optional package<br />

based on the family of products and place your order<br />

Scope of delivery:<br />

Description of services in 4 languages + service device label<br />

with a license number for identifying the additional agreement<br />

on the device<br />

Activation of the service license number for a SIMATIC <strong>PC</strong>/<br />

SIMATIC PG via the Internet (www.siemens.com/ped):<br />

The registration must be completed within the first 90 days<br />

after initial delivery of the device!


■ Overview<br />

■ Our core competencies<br />

■ Reference applications<br />

■ Contacts<br />

Activation of the Competence Centers for your application via<br />

your regional contact.<br />

If you do not yet have a contact person in your region, just go to:<br />

www.siemens.com/automation/partner<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Appendix<br />

Service & Support<br />

Expertise and services relating to<br />

all aspects of <strong>PC</strong>-based Automation<br />

Expertise and services relating to all aspects<br />

of <strong>PC</strong>-based Automation<br />

Do you require support with the dimensioning and options of a<br />

<strong>PC</strong>-based Automation project, or even engineering support?<br />

Specifically for this purpose, <strong>Siemens</strong> has established a team of<br />

specialists in Cologne and Milan who work closely with Development<br />

and Product Marketing and can thus provide our sales<br />

departments worldwide with competent support in <strong>PC</strong>-based<br />

Automation.<br />

Design of <strong>PC</strong>-based Automation systems from <strong>Siemens</strong><br />

Integrated, customer-specific technology (add-ons) using<br />

high-level languages (C++) in Windows or real-time environments<br />

Knowledge transfer/workshops for the integration of thirdparty<br />

components, as well as for applications using the Open<br />

Development Kit (ODK)<br />

Technology and application know-how<br />

Development of add-ons for WinAC and WinCC flexible<br />

Fast recording of measured values<br />

Software blocks for drives library<br />

Customer-specific communications via Ethernet<br />

(O<strong>PC</strong>/ActiveX, TCP socket)<br />

Synchronous operation, flying shear, table interpolation for<br />

electric and hydraulic axes<br />

Integration of <strong>PC</strong>I cards into <strong>PC</strong>-based Automation applications<br />

(e.g. WinAC and ASi-Bus)<br />

Customer-specific development and integration of C++<br />

programs<br />

Database connections<br />

Integration of complex control algorithms<br />

The latest information about the workshops offered can be found<br />

on the Internet:<br />

www.siemens.com/pc-based<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

7/13<br />

7


7<br />

Appendix<br />

Software Licenses<br />

■ Übersicht<br />

Software types<br />

Software requiring a license is categorized into types.<br />

The following software types have been defined:<br />

Engineering software<br />

Runtime software<br />

Engineering software<br />

This includes all software products for creating (engineering)<br />

user software, e.g. for configuring, programming, parameterizing,<br />

testing, commissioning or servicing.<br />

Data generated with engineering software and executable<br />

programs can be duplicated for your own use or for use by thirdparties<br />

free-of-charge.<br />

Runtime software<br />

This includes all software products required for plant/machine<br />

operation, e.g. operating system, basic system, system expansions,<br />

drivers, etc.<br />

The duplication of the runtime software and executable programs<br />

created with the runtime software for your own use or for<br />

use by third-parties is subject to a charge.<br />

You can find information about license fees according to use in<br />

the ordering data (e.g. in the catalog). Examples of categories of<br />

use include per CPU, per installation, per channel, per instance,<br />

per axis, per control loop, per variable, etc.<br />

Information about extended rights of use for parameterization/configuration<br />

tools supplied as integral components of the<br />

scope of delivery can be found in the readme file supplied with<br />

the relevant product(s).<br />

License types<br />

<strong>Siemens</strong> Industry Automation & Drive Technologies offers various<br />

types of software license:<br />

Floating license<br />

Single license<br />

Rental license<br />

Trial license<br />

Floating license<br />

The software may be installed for internal use on any number of<br />

devices by the licensee. Only the concurrent user is licensed.<br />

The concurrent user is the person using the program. Use<br />

begins when the software is started.<br />

A license is required for each concurrent user.<br />

Single license<br />

Unlike the floating license, a single license permits only one<br />

installation of the software.<br />

The type of use licensed is specified in the ordering data and<br />

in the Certificate of License (CoL). Types of use include for<br />

example per device, per axis, per channel, etc.<br />

One single license is required for each type of use defined.<br />

Rental license<br />

A rental license supports the "sporadic use" of engineering<br />

software. Once the license key has been installed, the software<br />

can be used for a specific number of hours (the operating hours<br />

do not have to be consecutive).<br />

One license is required for each installation of the software.<br />

Trial license<br />

A trial license supports "short-term use" of the software in a nonproductive<br />

context, e.g. for testing and evaluation purposes.<br />

It can be transferred to another license.<br />

7/14<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Factory license<br />

With the Factory License the user has the right to install and use<br />

the software at one permanent establishment only. The permanent<br />

establishment is defined by one address only.The number<br />

of hardware devices on which the software may be installed<br />

results from the order data or the Certificate of License (CoL).<br />

Certificate of license<br />

The Certificate of License (CoL) is the licensee's proof that the<br />

use of the software has been licensed by <strong>Siemens</strong>. A CoL is<br />

required for every type of use and must be kept in a safe place.<br />

Downgrading<br />

The licensee is permitted to use the software or an earlier version/release<br />

of the software, provided that the licensee owns<br />

such a version/release and its use is technically feasible.<br />

Delivery versions<br />

Software is constantly being updated.<br />

The following delivery versions<br />

PowerPack<br />

Upgrade<br />

can be used to access updates.<br />

Existing bug fixes are supplied with the ServicePack version.<br />

PowerPack<br />

PowerPacks can be used to upgrade to more powerful software.<br />

The licensee receives a new license agreement and CoL<br />

(Certificate of License) with the PowerPack. This CoL, together<br />

with the CoL for the original product, proves that the new software<br />

is licensed.<br />

A separate PowerPack must be purchased for each original<br />

license of the software to be replaced.<br />

Upgrade<br />

An upgrade permits the use of a new version of the software on<br />

the condition that a license for a previous version of the product<br />

is already held.<br />

The licensee receives a new license agreement and CoL with<br />

the upgrade. This CoL, together with the CoL for the previous<br />

product, proves that the new version is licensed.<br />

A separate upgrade must be purchased for each original license<br />

of the software to be upgraded.<br />

ServicePack<br />

ServicePacks are used to debug existing products.<br />

ServicePacks may be duplicated for use as prescribed according<br />

to the number of existing original licenses.<br />

License key<br />

<strong>Siemens</strong> Industry Automation & Drive Technologies supplies<br />

software products with and without license keys.<br />

The license key serves as an electronic license stamp and<br />

is also the "switch" for activating the software (floating license,<br />

rental license, etc.).<br />

The complete installation of software products requiring license<br />

keys includes the program to be licensed (the software) and the<br />

license key (which represents the license).<br />

Detailed explanations concerning license conditions can be found in the<br />

“Terms and Conditions of <strong>Siemens</strong> AG” or under<br />

www.siemens.com/industrymall<br />

(Industry Mall Online-Help System)


Numerics<br />

19" slide-in keyboard PS/2 with trackball................................................ 5/298<br />

2150 ........................................................................................................ 5/293<br />

2250 ........................................................................................................ 5/294<br />

A<br />

Accessories for fully enclosed HMI devices.................. 3/17, 3/18, 3/19, 3/20<br />

Accessories for SIMATIC Mobile Panels................................................. 2/206<br />

Adapter sets ............................................................................................. 3/17<br />

ADDM - Data Management .................................................................... 5/278<br />

Automotive industry ....................................................... 6/36, 6/39, 6/43, 6/45<br />

B<br />

Basic Panels ............................................................................................. 2/20<br />

Basic Panels – Standard........................................................................... 2/20<br />

Battery module 24 V/2.5 Ah<br />

Battery module 24 V/3.2 Ah .................................................................... 5/285<br />

Battery module 24 V/7 Ah<br />

Battery module 24 V/12 Ah ..................................................................... 5/286<br />

Box <strong>PC</strong> ......................................................... 5/58, 5/62, 5/70, 5/79, 5/88, 5/97<br />

BSP SIMATIC I<strong>PC</strong> V3.0 for RMOS3......................................................... 5/250<br />

C<br />

<strong>Catalog</strong> improvement suggestions........................................................... 7/20<br />

Charging station ..................................................................................... 2/211<br />

Comfort Panels ......................................................................................... 2/34<br />

Comfort Panels – Standard....................................................................... 2/34<br />

Communication – Indusrial Ethernet............................................ 5/302, 5/303<br />

Communication – Industrial Ethernet.................... 5/305, 5/306, 5/308, 5/309,<br />

...............................................................................5/310, 5/311, 5/313, 5/315,<br />

.....................................................................5/317, 5/319, 5/320, 5/322, 5/323<br />

Communication – PROFIBUS .................... 5/324, 5/325, 5/327, 5/329, 5/331,<br />

...............................................................................5/333, 5/335, 5/336, 5/337,<br />

................................................................................5/338, 5/339, 5/341, 5/343<br />

Conditions of sale and delivery, Export regulations ................................. 7/22<br />

Connecting cables.................................................................................. 2/199<br />

Connection options to SIMATIC <strong>PC</strong>s ........................................... 5/302, 5/324<br />

Converters/adapters ............................................................................... 2/214<br />

Cover foils ............................................................................................... 2/218<br />

CP 1604 .................................................................................................. 5/303<br />

CP 1612 A2............................................................................................. 5/306<br />

CP 1613 A2............................................................................................. 5/308<br />

CP 1616 .................................................................................................. 5/305<br />

CP 1623 .................................................................................................. 5/309<br />

CP 1628 .................................................................................................. 5/310<br />

CP 5512 .................................................................................................. 5/335<br />

CP 5603 .................................................................................................. 5/325<br />

CP 5611 A2............................................................................................. 5/336<br />

CP 5613 A2............................................................................................. 5/327<br />

CP 5614 A2............................................................................................. 5/329<br />

CP 5621 .................................................................................................. 5/337<br />

CP 5623 .................................................................................................. 5/331<br />

CP 5624 .................................................................................................. 5/333<br />

CP 5711 .................................................................................................. 5/338<br />

Customized Automation.............................................................................. 6/2<br />

Customized hardware.......................................................................... 6/4, 6/5<br />

Customized software .............................................................. 6/28, 6/29, 6/30<br />

D<br />

DC UPS module 40 A<br />

Battery module 24 V/1.2 Ah .................................................................... 5/284<br />

DC UPS module 6 A ............................................................................... 5/283<br />

DC UPS uninterruptible power supplies ................................................. 5/2<strong>80</strong><br />

DC UPS with battery modules ................................................................ 5/281<br />

DC UPS with capacitors ......................................................................... 5/287<br />

Design products ......................................................................................... 6/5<br />

Devices with stainless steel front................. 3/21, 3/22, 3/27, 3/33, 3/38, 3/45<br />

E<br />

EC31 ....................................................................................................... 5/176<br />

Embedded Box <strong>PC</strong> bundles ........................................................ 5/192, 5/196<br />

Embedded bundles/Software Packages ................................................ 5/191<br />

Embedded bundles/Software packages ................................................ 5/191<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Appendix Index<br />

Embedded Controller ............................................ 5/174, 5/176, 5/187, 5/188<br />

Embedded Panel <strong>PC</strong> bundles..................................................... 5/201, 5/205<br />

Examples of sector products.................................................................... 6/33<br />

Expansion components and accessories ............ 5/255, 5/257, 5/258, 5/259,<br />

....................................................................5/260, 5/266, 5/268, 5/271, 5/273,<br />

....................................................................5/275, 5/277, 5/278, 5/2<strong>80</strong>, 5/281,<br />

....................................................................5/283, 5/284, 5/285, 5/286, 5/287,<br />

....................................................................5/288, 5/289, 5/290, 5/291, 5/292,<br />

....................................................................5/293, 5/294, 5/295, 5/296, 5/297,<br />

................................................................................5/298, 5/299, 5/300, 5/301<br />

Expansion components/accessories ..................................................... 5/255<br />

Expansion modules ................................................................................ 5/188<br />

Expertise and services relating to all aspects<br />

of <strong>PC</strong>-based Automation .......................................................................... 7/12<br />

Extension units ......................................................................................... 3/18<br />

F<br />

Fixing elements ...................................................................................... 2/220<br />

Flat Panels 6.4" and 10.4" for Panel <strong>PC</strong>.................................................... 6/53<br />

Flat Panels with stainless steel front......................................................... 6/61<br />

Flexible front design concept for HMI products......................................... 6/9<br />

Food and beverage industry, pharmaceuticals ... 6/54, 6/56, 6/59, 6/61, 6/63<br />

Front panel 15" Touch and Keys for Panel <strong>PC</strong>s,<br />

resistant to honing oil................................................................................ 6/51<br />

Front panel with arrow keys on the side ................................................... 6/43<br />

Fully enclosed HMI devices ....................................... 3/3, 3/5, 3/8, 3/10, 3/12<br />

G<br />

General machine construction ...................................... 6/48, 6/50, 6/51, 6/53<br />

H<br />

HARDNET IE S7-REDCONNECT............................................................ 5/311<br />

HMI Accessories ....................................... 2/198, 2/199, 2/204, 2/205, 2/206,<br />

....................................................................2/208, 2/210, 2/211, 2/212, 2/213,<br />

.....................................................................2/214, 2/215, 2/217, 2/218, 2/220<br />

HMI devices for hazardous areas .......................................... 3/51, 3/53, 3/56<br />

HMI operator stations ...................................................................... 6/24, 6/36<br />

HMI Panels as rear-mounted devices ...................................................... 6/59<br />

HMI RFID module ..................................................................................... 6/48<br />

HMI Software .............................................................................................. 4/2<br />

HMI software in the TIA Portal ............................................................. 4/4, 4/5<br />

HMI software in the TIA portal .................................................................... 4/4<br />

HMI stainless steel operator stations ....................................................... 6/63<br />

I<br />

IE FC RJ45 Plug 2 x 2............................................................................. 2/205<br />

Index......................................................................................................... 7/14<br />

Industrial Monitors and Thin Clients ........... 5/214, 5/220, 5/221, 5/223, 5/226<br />

Industrial <strong>PC</strong> ............................................................................................... 5/2<br />

Industrial USB Hub 4................................................................... 2/198, 5/266<br />

Information and Ordering<br />

in the Internet and on DVD ......................................................................... 7/7<br />

Input and output devices ....................................................................... 5/289<br />

Introduction............................................................ 2/2, 3/2, 3/3, 3/21, 4/2, 6/2<br />

IP65 keyboards......................................................................................... 3/19<br />

IP65 membrane keyboard, 19" built-in version....................................... 5/297<br />

IP65 membrane keyboard, desk version................................................ 5/296<br />

K<br />

Key Panels......................................................................................... 2/9, 2/12<br />

Knowledge ............................................................................................... 7/10<br />

L<br />

Length key for connecting cables............................................................ 7/19<br />

M<br />

MA<strong>ST</strong>ERGUARD power supply.............................................................. 5/301<br />

Memory media........................................................................................ 2/213<br />

Micro Panels.................................................................. 2/85, 2/88, 2/91, 2/95<br />

Mobile Panel 277 10" Remote Operate .................................................... 6/45<br />

Mobile Panels ........................................................................................... 2/47<br />

Mobile Panels – 170 series....................................................................... 2/51<br />

Mobile Panels - 270 series ....................................................................... 2/61<br />

Mobile Panels – 270 series....................................................................... 2/69<br />

MP 177 6" Touch portrait .......................................................................... 6/50<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

7/15<br />

7


7<br />

Appendix<br />

Index<br />

MP 270 data display ................................................................................. 6/12<br />

MP 277 6" Touch portrait........................................................................... 6/16<br />

MP 277 8" Touch control console.............................................................. 6/13<br />

MP 277 8" Touch portrait........................................................................... 6/14<br />

MP 377 15" Touch daylight readable ........................................................ 6/65<br />

Multi Panel options.................................................................................. 2/169<br />

Multi Panels – 170 series ........................................................................ 2/146<br />

Multi Panels – 270 series ........................................................................ 2/151<br />

Multi Panels – 370 series ........................................................................ 2/160<br />

N<br />

Notes......................................................................................................... 7/21<br />

O<br />

OEM products....................... 6/8, 6/9, 6/11, 6/12, 6/13, 6/14, 6/16, 6/17, 6/21<br />

Oil & gas/chemicals/marine.................................................... 6/64, 6/65, 6/67<br />

Online Services........................................................................................... 7/7<br />

O<strong>PC</strong> server for Industrial Ethernet .......................................................... 5/317<br />

O<strong>PC</strong> server for PROFIBUS...................................................................... 5/341<br />

Operating channel extensions (active)................................................... 5/300<br />

Order No. Index ........................................................................................ 7/17<br />

Overview ..................................................................................................... 3/2<br />

P<br />

Panel <strong>PC</strong> 677B with 46" ............................................................................ 6/21<br />

Panels – 170 series........................................................... 2/114, 2/119, 2/126<br />

Panels - 270 series ................................................................................. 2/131<br />

Panels – 270 series................................................................................. 2/136<br />

Panels - 70 series ........................................................................ 2/101, 2/105<br />

Panels – 70 series................................................................................... 2/109<br />

Panels and Panel <strong>PC</strong>s with stainless steel front ....................................... 6/56<br />

Partner at Industry Automation and Drive Technologies ............................ 7/4<br />

<strong>PC</strong> I/O ..................................................................................................... 5/260<br />

<strong>PC</strong>-based Controller .............................................. 5/149, 5/151, 5/161, 5/171<br />

PP17 with PROFIBUS and PROFINET ...................................................... 6/39<br />

Printers.................................................................................................... 2/221<br />

Protective covers .................................................................................... 2/217<br />

R<br />

Rack <strong>PC</strong> ......................................................... 5/4, 5/10, 5/19, 5/27, 5/37, 5/48<br />

Rear panel cover ...................................................................................... 6/26<br />

Recommended printers for operator panels .......................................... 2/221<br />

Remote Operate Software ........................................................................ 6/29<br />

Renewable energy........................................................................... 6/34, 6/35<br />

RMOS3 real-time operating system................................. 5/230, 5/231, 5/238,<br />

...........................................................................................5/243, 5/247, 5/250<br />

RMOS3 V3.50 real-time operating system.............................................. 5/231<br />

RMOS3-GNU V3.0 .................................................................................. 5/238<br />

RMOS3-GRAPHX V1.0............................................................................ 5/247<br />

RMOS3-TCP/IP V3.0 ............................................................................... 5/243<br />

RS485 bus connector ............................................................................. 2/204<br />

S<br />

S7 O<strong>PC</strong> Redundancy for Industrial Ethernet .......................................... 5/319<br />

S7 O<strong>PC</strong> Redundancy for PROFIBUS...................................................... 5/343<br />

SCADA system SIMATIC WinCC .............................................................. 4/70<br />

SCADA System WinCC Open Architecture ............................................ 4/135<br />

SCD desk monitors SCD 19101.............................................................. 5/221<br />

SCD monitors.......................................................................................... 5/220<br />

SCD monitors 1900................................................................................. 5/223<br />

Service & Support....................................................................................... 7/8<br />

Service packs ......................................................................................... 2/215<br />

<strong>Siemens</strong> contacts worldwide ...................................................................... 7/4<br />

<strong>Siemens</strong> Service Option for SIMATIC <strong>PC</strong> / PG.......................................... 7/11<br />

<strong>Siemens</strong> Solution Partner............................................................................ 7/6<br />

SIMATIC 505 ........................................................................................... 2/184<br />

SIMATIC BATCH for WinCC .................................................................... 4/126<br />

SIMATIC Box <strong>PC</strong> 827B.............................................................................. 5/97<br />

SIMATIC Flat Panel PRO ........................................................................... 3/10<br />

SIMATIC Flat Panels................................................................................ 5/214<br />

SIMATIC HMI I<strong>PC</strong>227D ........................................................................... 5/109<br />

7/16<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

SIMATIC HMI I<strong>PC</strong>277D bundles............................................................. 5/201<br />

SIMATIC HMI I<strong>PC</strong>477C........................................................................... 5/116<br />

SIMATIC HMI I<strong>PC</strong>477C bundles............................................................. 5/205<br />

SIMATIC HMI I<strong>PC</strong>477C PRO .................................................................... 3/12<br />

SIMATIC HMI I<strong>PC</strong>577C........................................................................... 5/126<br />

SIMATIC HMI I<strong>PC</strong>677C........................................................................... 5/134<br />

SIMATIC HMI I<strong>PC</strong>677C INOX ................................................................... 3/45<br />

SIMATIC HMI KP8/KP8F ............................................................................. 2/9<br />

SIMATIC HMI Net Panel............................................................................ 6/17<br />

SIMATIC HMI Panel <strong>PC</strong> Ex ....................................................................... 3/53<br />

SIMATIC HMI Thin Client Ex ..................................................................... 3/56<br />

SIMATIC Industrial <strong>PC</strong> ................................................................................ 5/2<br />

SIMATIC I<strong>PC</strong> (Service) USB FlashDrive ................................................. 5/258<br />

SIMATIC I<strong>PC</strong> BIOS Manager .................................................................. 5/277<br />

SIMATIC I<strong>PC</strong> CompactFlash................................................................... 5/257<br />

SIMATIC I<strong>PC</strong> DiagMonitor ...................................................................... 5/273<br />

SIMATIC I<strong>PC</strong> Image & Partition Creator ................................................. 5/271<br />

SIMATIC I<strong>PC</strong> Remote Manager .............................................................. 5/275<br />

SIMATIC I<strong>PC</strong>227D .................................................................................... 5/62<br />

SIMATIC I<strong>PC</strong>227D bundles .................................................................... 5/192<br />

SIMATIC I<strong>PC</strong>427C .................................................................................... 5/70<br />

SIMATIC I<strong>PC</strong>427C bundles .................................................................... 5/196<br />

SIMATIC I<strong>PC</strong>547C .................................................................................... 5/19<br />

SIMATIC I<strong>PC</strong>547D .................................................................................... 5/10<br />

SIMATIC I<strong>PC</strong>627C .................................................................................... 5/79<br />

SIMATIC I<strong>PC</strong>647C .................................................................................... 5/27<br />

SIMATIC I<strong>PC</strong>827C .................................................................................... 5/88<br />

SIMATIC I<strong>PC</strong>847C .................................................................................... 5/37<br />

SIMATIC KNX/EIB2S7............................................................................... 6/30<br />

SIMATIC Logon.............................................................................. 4/31, 4/130<br />

SIMATIC Logon for WinCC flexible........................................................... 4/58<br />

SIMATIC Maintenance Station ................................................................ 4/102<br />

SIMATIC Mobile Panel 177 ....................................................................... 2/51<br />

SIMATIC Mobile Panel 277 ....................................................................... 2/61<br />

SIMATIC Mobile Panel 277(F) IWLAN ...................................................... 2/69<br />

SIMATIC MP 177..................................................................................... 2/146<br />

SIMATIC MP 277..................................................................................... 2/151<br />

SIMATIC MP 277 INOX ............................................................................. 3/27<br />

SIMATIC MP 377..................................................................................... 2/160<br />

SIMATIC MP 377 INOX ............................................................................. 3/33<br />

SIMATIC MP 377 PRO ................................................................................ 3/5<br />

SIMATIC OP 177B .................................................................................. 2/126<br />

SIMATIC OP 277 6"................................................................................. 2/136<br />

SIMATIC OP 73....................................................................................... 2/101<br />

SIMATIC OP 73micro................................................................................ 2/91<br />

SIMATIC OP 77A .................................................................................... 2/105<br />

SIMATIC OP 77B .................................................................................... 2/109<br />

SIMATIC Panel <strong>PC</strong> ........................... 5/105, 5/109, 5/116, 5/126, 5/134, 5/141<br />

SIMATIC Panel <strong>PC</strong> 677B......................................................................... 5/141<br />

SIMATIC Panel <strong>PC</strong> Remote Kit ............................................................... 5/268<br />

SIMATIC Panel <strong>PC</strong> 677B INOX ................................................................. 3/38<br />

SIMATIC <strong>PC</strong> function cards ...................................................................... 6/11<br />

SIMATIC <strong>PC</strong> keyboard............................................................................ 5/295<br />

SIMATIC <strong>PC</strong> mouse ................................................................................ 5/299<br />

SIMATIC <strong>PC</strong>-based controllers............................................................... 5/149<br />

SIMATIC Powerrate................................................................................. 4/106<br />

SIMATIC PP17 .......................................................................................... 2/15<br />

SIMATIC PP7 ............................................................................................ 2/12<br />

SIMATIC ProAgent.................................................................................. 4/150<br />

SIMATIC ProAgent process diagnosis software..................................... 4/150<br />

SIMATIC Rack <strong>PC</strong> 647B ........................................................................... 5/48<br />

SIMATIC S5............................................................................................. 2/182<br />

SIMATIC S7.................................................................................. 2/179, 2/192<br />

SIMATIC Thin Client................................................................................ 5/226<br />

SIMATIC Thin Client PRO ........................................................................... 3/8<br />

SIMATIC TP 177A ................................................................................... 2/114<br />

SIMATIC TP 177B ................................................................................... 2/119<br />

SIMATIC TP 177B INOX............................................................................ 3/22


SIMATIC TP 177micro ............................................................................... 2/95<br />

SIMATIC TP 277 6" .................................................................................. 2/131<br />

SIMATIC WinAC MP ................................................................................ 2/169<br />

SIMATIC WinAC ODK ............................................................................. 5/171<br />

SIMATIC WinAC RTX............................................................................... 5/151<br />

SIMATIC WinAC RTX F............................................................................ 5/161<br />

SIMATIC WinCC ........................................................................................ 4/70<br />

SIMATIC WinCC (TIA Portal) Engineering .................................................. 4/5<br />

SIMATIC WinCC (TIA Portal) options ..................................... 4/25, 4/26, 4/28,<br />

...............................................................................4/30, 4/31, 4/32, 4/36, 4/38<br />

SIMATIC WinCC (TIA Portal) Runtime.............................. 4/9, 4/10, 4/14, 4/19<br />

SIMATIC WinCC flexible ES ...................................................................... 4/41<br />

SIMATIC WinCC flexible HMI system .............................................. 4/41, 4/46<br />

SIMATIC WinCC flexible options................................... 4/53, 4/54, 4/55, 4/56,<br />

......................................................................4/57, 4/58, 4/60, 4/64, 4/67, 4/69<br />

SIMATIC WinCC flexible RT ...................................................................... 4/46<br />

SIMATIC WinCC options .................................... 4/88, 4/89, 4/91, 4/96, 4/100,<br />

....................................................................4/101, 4/102, 4/105, 4/106, 4/109,<br />

....................................................................4/113, 4/115, 4/117, 4/120, 4/123,<br />

...............................................4/124, 4/125, 4/126, 4/128, 4/130, 4/131, 4/132<br />

SINEMA E ............................................................................................... 5/322<br />

SINEMA server........................................................................................ 5/323<br />

Single-port USB interface ......................................................................... 3/20<br />

SINUMERIK 3.5" floppy disk drive, USB 1.1........................................... 5/259<br />

SIPLUS Basic Panels ................................................................................ 2/32<br />

SIPLUS HMI MP 177 ............................................................................... 2/175<br />

SIPLUS HMI MP 277 ............................................................................... 2/176<br />

SIPLUS HMI MP377 ................................................................................ 2/177<br />

SIPLUS HMI OP 177B............................................................................. 2/144<br />

SIPLUS HMI OP 73 ................................................................................. 2/141<br />

SIPLUS HMI OP 77B............................................................................... 2/142<br />

SIPLUS HMI TP 177B.............................................................................. 2/143<br />

SIPLUS HMI TP 277 6" ............................................................................ 2/145<br />

SIPLUS Junction boxes .......................................................................... 2/210<br />

SIPLUS Micro Panels ..................................................................... 2/99, 2/100<br />

SIPLUS Multi Panels for 170 series......................................................... 2/175<br />

SIPLUS Multi Panels for 270 series......................................................... 2/176<br />

SIPLUS Multi Panels for 370 series......................................................... 2/177<br />

SIPLUS Panels for 170 series ...................................................... 2/143, 2/144<br />

SIPLUS Panels for 270 series ................................................................. 2/145<br />

SIPLUS Panels for 70 series ........................................................ 2/141, 2/142<br />

SIPLUS PP17 ............................................................................................ 2/19<br />

SIPLUS Push Button Panels...................................................................... 2/19<br />

SIPLUS S7-200 TD 200............................................................................. 2/99<br />

SIPLUS S7-200 TD 400C ........................................................................ 2/100<br />

SIPLUS S7-modular embedded controller ............................................. 5/187<br />

SITOP UPS500S...................................................................................... 5/288<br />

SNMP O<strong>PC</strong> server .................................................................................. 5/320<br />

SOFTNET for Industrial Ethernet............................................................. 5/313<br />

SOFTNET for PROFIBUS ........................................................................ 5/339<br />

SOFTNET PN IO...................................................................................... 5/315<br />

Software Licenses..................................................................................... 7/13<br />

Software packages ................................................................................. 5/212<br />

Software products..................................................................................... 6/28<br />

Solar systems............................................................................................ 6/34<br />

Standards and approvals ........................................................................... 7/3<br />

System interfaces with WinCC (TIA Portal)....................... 2/191, 2/192, 2/194<br />

System interfaces with WinCC flexible ....... 2/178, 2/179, 2/182, 2/184, 2/185<br />

T<br />

T 2240/24 ................................................................................................ 5/291<br />

T 2240/9 .................................................................................................. 5/290<br />

T 2340/24 ................................................................................................ 5/292<br />

TEK – Temperature Extension Kit.............................................................. 6/67<br />

Terminal boxes........................................................................................ 2/208<br />

Text Display TD 200 .................................................................................. 2/85<br />

Text Display TD 400C ............................................................................... 2/88<br />

The unmatched complete service<br />

for the entire life cycle................................................................................. 7/8<br />

Third-party controllers.................................................................. 2/185, 2/194<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Appendix Index<br />

Training ....................................................................................................... 7/2<br />

Transponder ........................................................................................... 2/212<br />

Turnkey products.................................................................... 6/23, 6/24, 6/26<br />

W<br />

WinCC add-ons and partner management ............................................ 4/133<br />

WinCC Audit ............................................................................................. 4/30<br />

WinCC Competence Centers ..................................................................... 7/5<br />

WinCC flexible /Archives .......................................................................... 4/55<br />

WinCC flexible /Audit................................................................................ 4/57<br />

WinCC flexible /ChangeControl................................................................ 4/54<br />

WinCC flexible /O<strong>PC</strong> server ..................................................................... 4/67<br />

WinCC flexible /ProAgent ......................................................................... 4/69<br />

WinCC flexible /Recipes........................................................................... 4/56<br />

WinCC flexible /Sm@rtAccess.................................................................. 4/60<br />

WinCC flexible /Sm@rtService.................................................................. 4/64<br />

WinCC Logging ........................................................................................ 4/28<br />

WinCC Recipes ........................................................................................ 4/26<br />

WinCC Runtime Advanced....................................................................... 4/10<br />

WinCC Runtime Communication .............................................................. 4/19<br />

WinCC Runtime Professional.................................................................... 4/14<br />

WinCC Server / WinCC Client................................................................... 4/36<br />

WinCC Sm@rtServer................................................................................. 4/32<br />

WinCC WebNavigator............................................................................... 4/38<br />

WinCC/B.Data ........................................................................................ 4/109<br />

WinCC/Calendar Scheduler ................................................................... 4/124<br />

WinCC/Central Archive Server (CAS)..................................................... 4/100<br />

WinCC/ChangeControl & WinCC/Audit .................................................. 4/128<br />

WinCC/Connectivity Pack &<br />

WinCC Connectivity Station.................................................................... 4/117<br />

WinCC/DataMonitor................................................................................ 4/113<br />

WinCC/DowntimeMonitor ....................................................................... 4/115<br />

WinCC/Event Notifier .............................................................................. 4/125<br />

WinCC/IndustrialDataBridge .................................................................. 4/120<br />

WinCC/IndustrialX .................................................................................. 4/131<br />

WinCC/Open Development Kit (ODK).................................................... 4/132<br />

WinCC/ProAgent..................................................................................... 4/105<br />

WinCC/Redundancy............................................................................... 4/101<br />

WinCC/Server ........................................................................................... 4/89<br />

WinCC/TeleControl.................................................................................... 4/96<br />

WinCC/User Archives ............................................................................. 4/123<br />

WinCC/Web Navigator.............................................................................. 4/91<br />

Wind farms ................................................................................................ 6/35<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

7/17<br />

7


7<br />

Appendix<br />

Order No. Index<br />

2XV9<br />

2XV9 450- ........................................................................................4/18, 4/86<br />

6AG1<br />

6AG1 272- .................................................................................................2/99<br />

6AG1 500- ...............................................................................................2/204<br />

6AG1 640- ...............................................................................................2/100<br />

6AG1 641- ....................................................................................2/141, 2/142<br />

6AG1 642- .........................................................................2/143, 2/144, 2/175<br />

6AG1 643- ....................................................................................2/145, 2/176<br />

6AG1 644- ...............................................................................................2/177<br />

6AG1 647- .................................................................................................2/33<br />

6AG1 671- ...............................................................................................2/210<br />

6AG1 677- ...............................................................................................5/187<br />

6AG1 688- .................................................................................................2/19<br />

6AG1 931- ....................................................................................5/283, 5/284<br />

6AG4<br />

6AG4 070- ...............................................................................................5/199<br />

6AG4 104- ......................................................................5/16, 5/17, 5/24, 5/25<br />

6AG4 112- ......................................................................5/33, 5/34, 5/55, 5/56<br />

6AG4 114- ........................................................................................5/44, 5/45<br />

6AR1<br />

6AR1 403- ...................................................5/237, 5/242, 5/246, 5/249, 5/254<br />

6AR1 405- ...................................................5/237, 5/242, 5/246, 5/249, 5/254<br />

6AV2<br />

6AV2 100- ...................................................................................................4/7<br />

6AV2 101- ............................................................................................4/7, 4/8<br />

6AV2 102- ............................................................................................4/7, 4/8<br />

6AV2 103- ............................................................................................4/7, 4/8<br />

6AV2 104- .................................................................................................4/13<br />

6AV2 105- ........................................................................................4/13, 4/18<br />

6AV2 107- ..................................4/13, 4/18, 4/27, 4/29, 4/30, 4/35, 4/37, 4/40<br />

6AV2 114- ...............................................................................................5/213<br />

6AV2 115- ...............................................................................................5/213<br />

6AV2 124- ...............................................................................2/43, 2/219, 6/6<br />

6AV2 181- ......................................................................................2/43, 2/213<br />

6AV3<br />

AV3 671- ....................................................................................................6/42<br />

6AV3 678- ...............................................................................................2/215<br />

6AV3 688- ......................................................................2/10, 2/14, 2/17, 6/42<br />

6AV6<br />

6AV6 351- ..............................................................4/143, 4/144, 4/145, 4/146<br />

6AV6 352- ..............................................................4/146, 4/147, 4/148, 4/149<br />

6AV6 371- ............................4/81, 4/82, 4/83, 4/90, 4/94, 4/100, 4/101, 4/105<br />

....................................4/114, 4/119, 4/122, 4/123, 4/129, 4/131, 4/132, 4/154<br />

6AV6 372- ...................................................4/108, 4/112, 4/116, 4/124, 4/125<br />

6AV6 381- ...............................................................................4/81, 4/82, 4/83<br />

6AV6 382- ...............................................................................................5/213<br />

6AV6 551- ....................................................................................2/124, 2/130<br />

6AV6 574- ........................................2/207, 2/215, 2/216, 2/217, 2/219, 5/229<br />

6AV6 610- .................................................................................................4/44<br />

6AV6 611- .................................................................................................4/44<br />

6AV6 612- .................................................................................4/8, 4/44, 4/45<br />

6AV6 613- ...............................................................4/8, 4/44, 4/45, 4/51, 4/54<br />

6AV6 618- .......................4/51, 4/55, 4/56, 4/57, 4/63, 4/66, 4/68, 4/69, 4/154<br />

6AV6 621- ...........................................................................2/124, 2/130, 3/25<br />

6AV6 622- .......................................................2/134, 2/139, 2/158, 3/31, 3/37<br />

6AV6 623- ...............................................................................................5/213<br />

6AV6 640- ........................................................................2/90, 2/93, 2/98, 6/6<br />

7/18<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

6AV6 (continued)<br />

6AV6 641- ..................................................................2/104, 2/108, 2/112, 6/6<br />

6AV6 642- ............................2/117, 2/124, 2/130, 2/149, 3/25, 6/6, 6/50, 6/58<br />

6AV6 643- ..............................2/134, 2/139, 2/157, 3/31, 6/6, 6/32, 6/58, 6/60<br />

6AV6 644- ............................................. 2/167, 3/6, 3/37, 6/6, 6/58, 6/60, 6/66<br />

6AV6 645- ................................................2/59, 2/67, 2/82, 2/207, 2/219, 6/47<br />

6AV6 646- ........................................................................................3/9, 5/229<br />

6AV6 647- .......................................................................................... 2/29, 6/6<br />

6AV6 651- ........................................................................................2/29, 2/82<br />

6AV6 652- ...................................................2/124, 2/149, 2/157, 2/167, 2/174<br />

6AV6 653- ........................................................................................3/9, 5/229<br />

6AV6 671- ............................2/10, 2/59, 2/67, 2/82, 2/90, 2/100, 2/198, 2/207<br />

...............................................2/209, 2/211, 2/212, 2/213, 2/214, 2/215, 2/216<br />

.................................................2/217, 2/219, 2/220, 3/49, 5/123, 5/131, 5/139<br />

.......................................................................5/147, 5/211, 5/229, 5/267, 6/47<br />

6AV6 675- .............................................................................2/216, 6/49, 6/68<br />

6AV6 691- ..............................2/29, 2/59, 2/67, 2/83, 2/93, 2/98, 2/104, 2/108<br />

...............................................2/112, 2/117, 2/124, 2/130, 2/134, 2/139, 2/158<br />

.........................................................2/167, 3/25, 3/31, 3/37, 4/45, 4/51, 4/154<br />

6AV7<br />

6AV7 200- ........................................................................................3/54, 3/57<br />

6AV7 426- ................................................................................................. 6/20<br />

6AV7 461- ................................................................................................. 6/53<br />

6AV7 466- ................................................................................................. 6/22<br />

6AV7 476- ................................................................................................. 6/62<br />

6AV7 486- ................................................................................................. 6/62<br />

6AV7 671- ...............................3/43, 5/123, 5/131, 5/147, 5/211, 5/218, 5/269<br />

6AV7 672- ..............................2/216, 2/219, 3/43, 3/49, 5/17, 5/25, 5/35, 5/46<br />

............................................5/56, 5/76, 5/86, 5/95, 5/103, 5/114, 5/123, 5/131<br />

...............................................5/139, 5/147, 5/199, 5/203, 5/211, 5/218, 5/229<br />

...............................................................................................5/258, 6/20, 6/27<br />

6AV7 674- ......................................................................3/17, 3/18, 3/19, 3/20<br />

6AV7 675- ........................................................................................3/54, 3/57<br />

6AV7 860- .................................................................................... 5/218, 5/224<br />

6AV7 861- ...............................................................................3/11, 5/218, 6/7<br />

6AV7 862- ............................................................................................... 5/224<br />

6AV7 870- ............................................................................................... 5/147<br />

6AV7 872- ......................................................................................5/147, 6/58<br />

6AV7 873- ............................................................................................... 5/147<br />

6AV7 875- ............................................................................................... 5/147<br />

6AV7 883- .....................................................3/15, 5/122, 5/130, 5/210, 5/211<br />

6AV7 884- .........................................................................5/122, 5/210, 5/211<br />

6AV7 885- ............................................................................................... 5/130<br />

6AV7 890- ............................................................................................... 5/139<br />

6AV7 891- ............................................................................................... 5/139<br />

6AV7 892- ......................................................................................3/48, 5/139<br />

6AV7 893- ............................................................................................... 5/139<br />

6AV7 894- ............................................................................................... 5/139<br />

6BQ3<br />

6BQ3 030- ..............................................................................................5/279<br />

6DL5<br />

6DL5 000- .................................................................................................4/99<br />

6DL5 002- .................................................................................................4/99<br />

6DL5 101- .................................................................................................4/99<br />

6EP1<br />

6EP1 931- .....................................................3/43, 5/139, 5/147, 5/283, 5/284<br />

6EP1 933- ............................................................................................... 5/288<br />

6EP1 935- ......................3/43, 3/49, 5/139, 5/147, 5/284, 5/285, 5/286, 5/288<br />

6EP1 975- ............................................................................................... 5/288


6ES7<br />

6ES7 272- ......................................................................................2/87, 2/219<br />

6ES7 298- .................................................................................................2/90<br />

6ES7 647- ....................................................................5/75, 5/85, 5/94, 5/102<br />

6ES7 648- .........................................2/213, 3/43, 3/49, 5/17, 5/25, 5/35, 5/46<br />

.......................................................5/56, 5/76, 5/86, 5/95, 5/103, 5/123, 5/131<br />

..........................................................5/139, 5/147, 5/199, 5/211, 5/257, 5/258<br />

.....................................................................5/265, 5/272, 5/274, 5/276, 5/295<br />

6ES7 652- ........................................................................................4/18, 4/86<br />

6ES7 657- ...............................................................................................4/127<br />

6ES7 658- .............................................................................4/31, 4/59, 4/130<br />

6ES7 671- .........................................................................5/159, 5/169, 5/213<br />

6ES7 675- ....................................................................................5/198, 5/199<br />

6ES7 676- ...............................................................................................5/213<br />

6ES7 677- ....................................................................................5/186, 5/190<br />

6ES7 790- ....................................................5/17, 5/25, 5/35, 5/46, 5/56, 5/76<br />

.........................................................................5/86, 5/95, 5/103, 5/199, 5/299<br />

6ES7 <strong>80</strong>6- ...............................................................................................5/173<br />

6ES7 840- ...............................................................................................4/104<br />

6ES7 900- ...........................................3/43, 3/49, 5/17, 5/25, 5/35, 5/46, 5/56<br />

..............................................................5/86, 5/95, 5/103, 5/139, 5/147, 5/269<br />

6ES7 901- .....................................2/87, 2/90, 2/99, 2/100, 2/203, 2/204, 4/52<br />

6ES7 972- .............................................................................2/204, 4/24, 4/52<br />

6FC5<br />

6FC5 235- ...................................................5/123, 5/131, 5/147, 5/211, 5/259<br />

6GF6<br />

6GF6 220- ...............................................................................................5/221<br />

6GF6 520- ...................................................5/290, 5/291, 5/292, 5/293, 5/294<br />

6GF6 710- .........................................................................5/296, 5/297, 5/298<br />

6GF6 9<strong>80</strong>- ...............................................................................................5/300<br />

6GK1<br />

6GK1 160- ..............................................................5/159, 5/169, 5/199, 5/304<br />

6GK1 161- ..................................................4/23, 4/52, 4/83, 4/84, 4/85, 5/159<br />

.....................................................................5/169, 5/305, 5/307, 5/308, 5/312<br />

6GK1 162- ..................................................................4/23, 4/84, 5/309, 5/310<br />

6GK1 500- ...................................................2/204, 5/335, 5/336, 5/337, 5/338<br />

6GK1 551- ...........................................................4/24, 4/52, 4/84, 4/86, 5/335<br />

6GK1 560- ..............................................................5/159, 5/169, 5/199, 5/325<br />

6GK1 561- ................................................4/24, 4/52, 4/84, 4/86, 5/159, 5/169<br />

.....................................................................5/327, 5/329, 5/331, 5/333, 5/336<br />

6GK1 562- ................................................4/24, 4/52, 4/84, 4/86, 5/159, 5/169<br />

...........................................................................................5/331, 5/333, 5/337<br />

6GK1 571- ...........................................................4/24, 4/52, 4/84, 4/86, 5/338<br />

6GK1 704- ...................................4/23, 4/83, 4/85, 5/307, 5/314, 5/316, 5/340<br />

6GK1 706- ...................................................5/314, 5/318, 5/319, 5/321, 5/343<br />

6GK1 713- .................4/24, 4/52, 4/84, 4/85, 4/86, 5/327, 5/329, 5/331, 5/334<br />

6GK1 716- ..........................4/23, 4/52, 4/84, 4/86, 5/308, 5/309, 5/310, 5/312<br />

6GK1 781- ....................................................................................5/322, 5/323<br />

6GK1 782- ...............................................................................................5/322<br />

6GK1 901- ...............................................................................................2/205<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Appendix<br />

Order No. Index<br />

6GK5<br />

6GK5 204- ...................................................................................5/304, 5/305<br />

6GK5 784- ................................................................................................2/83<br />

6GK5 786- ................................................................................................2/83<br />

6GK5 788- ................................................................................................2/83<br />

6GK5 791- ................................................................................................2/83<br />

6XV1<br />

6XV1 440- .........................................................2/59, 2/67, 2/203, 2/207, 6/47<br />

6XV1 830- ............................................................................................... 2/203<br />

6XV1 840- ............................................................................................... 2/205<br />

6XV1 870- ..................2/203, 2/205, 5/304, 5/305, 5/307, 5/308, 5/309, 5/310<br />

A<br />

A5E01 .......................................................................................................5/46<br />

C<br />

C79459- ..................................................................................................5/335<br />

S<br />

S79220- ....................................................................................................4/82<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

7/19<br />

7


7<br />

Appendix<br />

Length key for connecting cables<br />

■ Length key for connecting cables<br />

On connecting cables whose length is freely selectable according<br />

to the following lists, the blanks (…) in the order no. must be<br />

completed in accordance with the length codes given.<br />

The different length keys must be taken into account here!<br />

Other lengths on request.<br />

7/20<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Length of the connecting cable =<br />

Multiplier x length key<br />

Multiplier<br />

00.1 m 6XV. …-..E..<br />

0.1 m 6XV. …-..H..<br />

1.0 m 6XV. …-..N..<br />

10.0 m 6XV. …-..T..<br />

100.0 m<br />

Length digit<br />

6XV. …-..U..<br />

10 6XV. …-…10<br />

12 6XV. …-…12<br />

15 6XV. …-…15<br />

16 6XV. …-…16<br />

20 6XV. …-…20<br />

25 6XV. …-…25<br />

32 6XV. …-…32<br />

40 6XV. …-…40<br />

50 6XV. …-…50<br />

60 6XV. …-…60<br />

63 6XV. …-…63<br />

<strong>80</strong> 6XV. …-…<strong>80</strong><br />

Order no. supplement of the<br />

connecting cable<br />

6XV. …-…..<br />

Ordering example:<br />

The 6XV1 404-0A… connecting cable must be 16 m long.<br />

Multiplier 1.0 m (N) x length digit 16 (16) gives a length of 16 m.<br />

The order no. supplement is N16.<br />

This is entered in the blank spaces of the order no.<br />

The complete order no. for the 16 m long connecting cable is<br />

then 6XV1 404-0AN16.


■ To Your address<br />

<strong>Siemens</strong> AG, I IA AS S ID 2<br />

<strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> • <strong>2011</strong> / Ms. B. Beyer<br />

Gleiwitzer Str. 555<br />

90475 Nürnberg<br />

Germany<br />

Fax. +49/911-895-15 31 14<br />

■ Your opinion is important to us!<br />

Our catalog should be an important and frequently used<br />

document. For this reason we are continuously endeavoring to<br />

improve it.<br />

■ We invite you to grade our catalog on a point system from 1 (= good) to 6 (= poor):<br />

■ Did you find any printing errors?<br />

Name<br />

Job<br />

Company/Department<br />

Street/No.<br />

Postal code/City<br />

Tel. No./Fax<br />

E-mail address<br />

Appendix<br />

<strong>Catalog</strong> improvement suggestions<br />

A small request on our part to you:<br />

Please take time to fill in the following form and fax it to us.<br />

Thank You!<br />

Do the contents of the catalog live up to your expectations? Do the technical details meet your expectations?<br />

Is the information easy to find? How would you assess the graphics and tables?<br />

Can the texts be readily understood?<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

7/21<br />

7


7<br />

Appendix<br />

Conditions of sale and delivery, Export regulations<br />

■ Terms and Conditions of Sale and Delivery<br />

By using this catalog you can acquire hardware and software<br />

products described therein from <strong>Siemens</strong> AG subject to the following<br />

terms. Please note! The scope, the quality and the conditions<br />

for supplies and services, including software products, by<br />

any <strong>Siemens</strong> entity having a registered office outside of Germany,<br />

shall be subject exclusively to the General Terms and<br />

Conditions of the respective <strong>Siemens</strong> entity. The following terms<br />

apply exclusively for orders placed with <strong>Siemens</strong> AG.<br />

For customers with a seat or registered office in Germany<br />

The “General Terms of Payment” as well as the “General Conditions<br />

for the Supply of Products and Services of the Electrical<br />

and Electronics Industry” shall apply.<br />

For software products, the “General License Conditions for Software<br />

Products for Automation and Drives for Customers with a<br />

Seat or registered Office in Germany” shall apply.<br />

For customers with a seat or registered office outside of<br />

Germany<br />

The “General Terms of Payment” as well as the “General Conditions<br />

for Supplies of <strong>Siemens</strong>, Automation and Drives for Customers<br />

with a Seat or registered Office outside of Germany” shall<br />

apply.<br />

For software products, the “General License Conditions for Software<br />

Products for Automation and Drives for Customers with a<br />

Seat or registered Office outside of Germany” shall apply.<br />

General<br />

The dimensions are in mm. In Germany, according to the German<br />

law on units in measuring technology, data in inches only<br />

apply to devices for export.<br />

Illustrations are not binding.<br />

Insofar as there are no remarks on the corresponding pages,<br />

- especially with regard to data, dimensions and weights given -<br />

these are subject to change without prior notice.<br />

The prices are in € (Euro) ex works, exclusive packaging.<br />

The sales tax (value added tax) is not included in the prices.<br />

It shall be debited separately at the respective rate according to<br />

the applicable legal regulations.<br />

Prices are subject to change without prior notice. We will debit<br />

the prices valid at the time of delivery.<br />

Surcharges will be added to the prices of products that contain<br />

silver, copper, aluminum, lead and/or gold if the respective basic<br />

official prices for these metals are exceeded. These surcharges<br />

will be determined based on the official price and the metal factor<br />

of the respective product.<br />

The surcharge will be calculated on the basis of the official price<br />

on the day prior to receipt of the order or prior to the release<br />

order.<br />

The metal factor determines the official price as of which the<br />

metal surcharges are charged and the calculation method used.<br />

The metal factor, provided it is relevant, is included with the price<br />

information of the respective products.<br />

An exact explanation of the metal factor and the text of the<br />

Comprehensive Terms and Conditions of Sale and Delivery are<br />

available free of charge from your local <strong>Siemens</strong> business office<br />

under the following Order Nos.:<br />

6ZB5310-0KR30-0BA1<br />

(for customers based in Germany)<br />

6ZB5310-0KS53-0BA1<br />

(for customers based outside Germany)<br />

or download them from the Internet<br />

www.siemens.com/industrymall<br />

(Germany: Industry Mall Online-Help System)<br />

7/22<br />

<strong>Siemens</strong> <strong>ST</strong> <strong>80</strong> / <strong>ST</strong> <strong>PC</strong> <strong>·</strong> <strong>2011</strong><br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

■ Export regulations<br />

Our obligation to fulfill this agreement is subject to the proviso<br />

that the fulfillment is not prevented by any impediments arising<br />

out of national and international foreign trade and customs<br />

requirements or any embargos and/or other sanctions.<br />

If you transfer goods (hardware and/ or software and/ or technology<br />

as well as corresponding documentation, regardless of<br />

the mode of provision) delivered by us or works and services<br />

(including all kinds of technical support) performed by us to a<br />

third party worldwide, you shall comply with all applicable<br />

national and international (re-) export control regulations.<br />

If required to conduct export control checks, you, upon request<br />

by us, shall promptly provide us with all information pertaining to<br />

particular end customer, destination and intended use of goods,<br />

works and services provided by us, as well as any export control<br />

restrictions existing.<br />

The products listed in this catalog / price list may be subject to<br />

European / German and/or US export regulations.<br />

Therefore, any export requiring a license is subject to approval<br />

by the competent authorities.<br />

According to current provisions, the following export regulations<br />

must be observed with respect to the products featured in this<br />

catalog / price list:<br />

AL Number of the German Export List<br />

Products marked other than “N” require an export<br />

license.<br />

In the case of software products, the export designations<br />

of the relevant data medium must also<br />

be generally adhered to.<br />

Goods labeled with an “AL“ not equal to “N” are<br />

subject to a European or German export authorization<br />

when being exported out of the EU.<br />

ECCN Export Control Classification Number<br />

Products marked other than “N” are subject to a<br />

reexport license to specific countries.<br />

In the case of software products, the export<br />

designations of the relevant data medium must<br />

also be generally adhered to.<br />

Goods labeled with an “ECCN“ not equal to “N”<br />

are subject to a US re-export authorization.<br />

Even without a label or with an “AL: N” or “ECCN: N”, authorization<br />

may be required due to the final destination and purpose for<br />

which the goods are to be used.<br />

The deciding factors are the AL or ECCN export authorization<br />

indicated on order confirmations, delivery notes and invoices.<br />

Errors excepted and subject to change without prior notice.


<strong>Catalog</strong>s<br />

Industry Automation, Drive Technologies and Low Voltage Distribution<br />

Further information can be obtained from our branch offices listed<br />

in the appendix or at www.siemens.com/automation/partner<br />

Interactive <strong>Catalog</strong> on DVD <strong>Catalog</strong><br />

for Industry Automation, Drive Technologies and<br />

Low Voltage Distribution<br />

CA 01<br />

Drive Systems<br />

Variable-Speed Drives<br />

SINAMICS G110, SINAMICS G120<br />

D11.1<br />

Standard Inverters<br />

SINAMICS G110D, SINAMICS G120D<br />

Distributed Inverters<br />

SINAMICS G130 Drive Converter Chassis Units D11<br />

SINAMICS G150 Drive Converter Cabinet Units<br />

SINAMICS GM150, SINAMICS SM150<br />

D12<br />

Medium-Voltage Converters<br />

SINAMICS S120 Chassis Format Units and<br />

D21.3<br />

Cabinet Modules<br />

SINAMICS S150 Converter Cabinet Units<br />

SINAMICS DCM Converter Units D23.1<br />

Three-phase Induction Motors<br />

D84.1<br />

• H-compact<br />

H-compact PLUS<br />

Asynchronous Motors Standardline D86.1<br />

Synchronous Motors with Permanent-Magnet<br />

D86.2<br />

Technology, HT-direct<br />

DC Motors DA 12<br />

SIMOREG DC MA<strong>ST</strong>ER 6RA70 Digital Chassis DA 21.1<br />

Converters<br />

SIMOREG K 6RA22 Analog Chassis Converters DA 21.2<br />

PDF: SIMOREG DC MA<strong>ST</strong>ER 6RM70 Digital Converter DA 22<br />

Cabinet Units<br />

SIMOVERT PM Modular Converter Systems DA 45<br />

SIEMOSYN Motors DA 48<br />

MICROMA<strong>ST</strong>ER 420/430/440 Inverters DA 51.2<br />

MICROMA<strong>ST</strong>ER 411/COMBIMA<strong>ST</strong>ER 411 DA 51.3<br />

SIMOVERT MA<strong>ST</strong>ERDRIVES Vector Control DA 65.10<br />

SIMOVERT MA<strong>ST</strong>ERDRIVES Motion Control DA 65.11<br />

Synchronous and asynchronous servomotors for DA 65.3<br />

SIMOVERT MA<strong>ST</strong>ERDRIVES<br />

SIMODRIVE 611 universal and POSMO DA 65.4<br />

SIMOTION, SINAMICS S120 and<br />

PM 21<br />

Motors for Production Machines<br />

SINAMICS S110<br />

PM 22<br />

The Basic Positioning Drive<br />

Low-Voltage Three-Phase-Motors<br />

IEC Squirrel-Cage Motors D81.1<br />

MOTOX Geared Motors D87.1<br />

Automation Systems for Machine Tools SIMODRIVE NC 60<br />

Motors<br />

Converter Systems SIMODRIVE 611/POSMO<br />

Automation Systems for Machine Tools SINAMICS NC 61<br />

Motors<br />

Drive System SINAMICS S120<br />

Mechanical Driving Machines<br />

FLENDER Standard Couplings MD 10.1<br />

FLENDER SIG Standard industrial gear unit MD 30.1<br />

Low-Voltage Power Distribution and<br />

Electrical Installation Technology<br />

Protection, Switching, Measuring & Monitoring Devices LV 10.1<br />

Switchboards and Distribution Systems LV 10.2<br />

GAMMA Building Management Systems ET G1<br />

PDF: DELTA Switches and Socket Outlets ET D1<br />

SICUBE System Cubicles and Cubicle Air-Conditioning LV 50<br />

SIVACON 8PS Busbar Trunking Systems LV 70<br />

PDF: These catalogs are only available as pdf files.<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Motion Control <strong>Catalog</strong><br />

SINUMERIK & SIMODRIVE<br />

NC 60<br />

Automation Systems for Machine Tools<br />

SINUMERIK & SINAMICS<br />

NC 61<br />

Equipment for Machine Tools<br />

SINUMERIK 828D BASIC T/BASIC M,<br />

NC 82<br />

SINAMICS S120 Combi and 1FK7/1PH8 motors<br />

SIMOTION, SINAMICS S120 and<br />

PM 21<br />

Motors for Production Machines<br />

SINAMICS S110<br />

PM 22<br />

The Basic Positioning Drive<br />

Power Supply and System Cabling<br />

Power supply SITOP KT 10.1<br />

System cabling SIMATIC TOP connect KT 10.2<br />

Process Instrumentation and Analytics<br />

Field Instruments for Process Automation FI 01<br />

SIREC Recorders and Accessories MP 20<br />

SIPART, Controllers and Software MP 31<br />

Products for Weighing Technology WT 10<br />

Process Analytical Instruments PA 01<br />

PDF: Process Analytics,<br />

Components for the System Integration<br />

PA 11<br />

Safety Integrated<br />

Safety Technology for Factory Automation SI 10<br />

SIMATIC HMI/<strong>PC</strong>-based Automation<br />

Human Machine Interface Systems/<br />

<strong>PC</strong>-based Automation<br />

<strong>ST</strong> <strong>80</strong>/<br />

<strong>ST</strong> <strong>PC</strong><br />

SIMATIC Ident<br />

Industrial Identification Systems ID 10<br />

SIMATIC Industrial Automation Systems<br />

Products for Totally Integrated Automation and <strong>ST</strong> 70<br />

Micro Automation<br />

SIMATIC <strong>PC</strong>S 7 Process Control System <strong>ST</strong> <strong>PC</strong>S 7<br />

Add-ons for the SIMATIC <strong>PC</strong>S 7<br />

<strong>ST</strong> <strong>PC</strong>S 7.1<br />

Process Control System<br />

PDF: Migration solutions with the SIMATIC <strong>PC</strong>S 7 <strong>ST</strong> <strong>PC</strong>S 7.2<br />

Process Control System<br />

SIMATIC NET<br />

Industrial Communication IK PI<br />

SINVERT Photovoltaics<br />

Inverters and Components for Photovoltaic Installations RE 10<br />

SIRIUS Industrial Controls<br />

SIRIUS Industrial Controls IC 10<br />

SIRIUS Industrial Controls<br />

IC 90<br />

(selected content from catalog IC 10)<br />

System Solutions<br />

Applications and Products for Industry are part of the<br />

interactive catalog CA 01<br />

Download-Center<br />

PDF versions of the catalogs are available on the Internet at:<br />

www.siemens.com/automation/infocenter


<strong>Siemens</strong> AG<br />

Industry Sector<br />

Industrial Automation Systems<br />

Postfach 48 48<br />

90026 NÜRNBERG<br />

GERMANY<br />

www.siemens.com/automation<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

Subject to change without prior notice<br />

Order No. E86060-K46<strong>80</strong>-A101-B8-7600<br />

3P.8301.03.04 / Dispo 07900<br />

KG 0711 10. S 888 En / IWI T<strong>ST</strong>E<br />

Printed in Germany<br />

© <strong>Siemens</strong> AG <strong>2011</strong><br />

The information provided in this catalog contains descriptions or<br />

characteristics of performance which in case of actual use do not<br />

always apply as described or which may change as a result of further<br />

development of the products. An obligation to provide<br />

the respective characteristics shall only exist if expressly agreed in the<br />

terms of contract. Availability and technical specifications are subject<br />

to change without notice.<br />

All product designations may be trademarks or product names<br />

of <strong>Siemens</strong> AG or supplier companies whose use by third<br />

parties for their own purposes could violate the rights of<br />

the owners.<br />

Token fee: 10.00 €

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!