ETA 060158 IMPERBEL Double layer UK renew Final - ETA-Danmark

etadanmark.dk

ETA 060158 IMPERBEL Double layer UK renew Final - ETA-Danmark

ETA-Danmark A/S

Kollegievej 6

DK-2920 Charlottenlund

Tel. +45 72 24 59 00

Fax +45 72 24 59 04

Internet www.etadanmark.dk

Authorised and notified according to

Article 10 of the Council Directive

89/106/EEC of 21 December 1988 on

the approximation of laws, regulations

and administrative provisions of

Member States relating to construction

products

European Technical Approval ETA-06/0158

MEMBER OF EOTA

This ETA is a renewal of the previous ETA with the same number and validity from 2006-09-06 to 2011-09-06

Trade name:

Holder of approval:

Generic type and use of construction

product:

Valid from:

to:

Manufacturing plant:

This European Technical

Approval contains:

DERBIGUM SP 3 FR on DERBICOAT HP 2,5 and

DERBICOLOR 4 FR on DERBICOAT HP 2,5 double

layer roof-waterproofing kits

Imperbel S. A.

Parc Industriel

B-1360 Perwez

Tel. +32 81 65 44 11

Fax +32 81 65 43 09

Double layer mechanically fastened roofwaterproofing

kit

2011-09-06

2016-09-06

Imperbel S. A.

Parc Industriel

B-1360 Perwez

21 pages including 4 Annexes which form an integral

part of the document


I LEGAL BASIS AND GENERAL

CONDITIONS

Page 2 of 21 of European Technical Approval no. ETA-06/0158

1 This European Technical Approval is issued by

ETA-Danmark A/S in accordance with:

- Council Directive 89/106/EEC of 21 December

1988 on the approximation of laws, regulations

and administrative provisions of Member States

relating to construction products 1) , as amended by

Council Directive 93/68/EEC of 22 July 1993 2) .

- Bekendtgørelse 559 af 27-06-1994 (afløser

bekendtgørelse 480 af 25-06-1991) om ikrafttræden

af EF direktiv af 21. december 1988 om

indbyrdes tilnærmelse af medlemsstaternes love

og administrative bestemmelser om byggevarer.

- Common Procedural Rules for Requesting,

Preparing and the Granting of European Technical

Approvals set out in the Annex to Commission

Decision 94/23/EC 3) .

- Guideline for European Technical Approval of

Mechanically fastened roof-waterproofing kits,

ETA-Guideline N o 006, Edition March 2000.

2 ETA-Danmark A/S is authorized to check whether

the provisions of this European Technical

Approval are met. Checking may take place in the

manufacturing plant. Nevertheless, the responsibility

for the conformity of the products to the

European Technical Approval and for their fitness

for the intended use remains with the holder of

the European Technical Approval.

3 This European Technical Approval is not to be

transferred to manufacturers or agents of manufacturers

other than those indicated on page 1, or

manufacturing plants other than those indicated

on page 1 of this European Technical Approval.

4 This European Technical Approval may be

withdrawn by ETA-Danmark A/S pursuant to

Article 5(1) of Council Directive89/106/EEC.

1) Official Journal of the European Communities N o L40, 11 Feb 1989, p 12.

2) Official Journal of the European Communities N o L220, 30 Aug 1993, p 1.

3) Official Journal of the European Communities N o L 17, 20 Jan 1994, p 34.

5 Reproduction of this European Technical Approval

including transmission by electronic means shall be

in full. However, partial reproduction can be made

with the written consent of ETA-Danmark A/S. In

this case partial reproduction has to be designated as

such. Texts and drawings of advertising brochures

shall not contradict or misuse the European Technical

Approval.

6 This European Technical Approval is issued by

ETA-Danmark A/S in Danish.

This version corresponds fully to the version circulated

within EOTA. Translations into other languages

have to be designated as such.


Page 3 of 21 of European Technical Approval no. ETA-06/0158

II SPECIAL CONDITIONS OF THE

EUROPEAN TECHNICAL APPROVAL

1 Definition of product and intended use

General

DERBIGUM SP 3 FR on DERBICOAT HP 2,5 and DERBICOLOR 4 FR on DERBICOAT HP 2,5 double layer

roof waterproofing kits consists of two membranes, which are glued together with a cold adhesive and the under layer

is mechanically fastened to the substrate.

The membranes are placed on a mineral wool insulation board, which is also mechanically fastened to the substrate.

The mineral wool boards are not part of the kit.

Membranes

DERBIGUM SP 3 FR is a membrane made from polymer modified bitumen (APP) with a double-layer reinforcement

in the top layer of the membrane of approx. 150 g/m 2 non-woven polyester felt and 55 g/m 2 fibreglass. DERBIGUM

SP 3 FR has a total thickness of 3 mm and a weight of 3,1 kg/m 2 . Standard width is 1,10 m.

DERBICOLOR 4 FR is a membrane made from polymer modified bitumen (APP) with reinforcement complex in the

middle layer of the membrane of approx. 185 g/m 2 non-woven polyester felt and fibreglass. DERBICOLOR 4 FR has

a total thickness of 4 mm and a weight of 5,3 kg/m 2 . Standard width is 1,10 m.

DERBICOAT HP 2,5 is a membrane made from polymer-modified bitumen (APP) with reinforcement complex in the

middle layer of the membrane of approx. 100 g/m 2 non-woven polyester felt and fibreglass. DERBICOAT HP 2,5 has

a total thickness of 2,5 mm and a weight of 2,9 kg/m 2 . Standard width is 1,10 m.

The membranes are supplied in roll form.

The different membranes and fasteners which can compose the mechanically fastened flexible roof waterproofing

membrane kit (in the following referred to as MEFAWAME) and their properties are presented in Annexes 1 and

2. The holder of the ETA is fundamentally responsible of the MEFAWAME. The flexible membranes which

constitute the MEFAWAME are exclusively distributed by Imperbel S.A., subsidiary companies and distributors

Fasteners

The different fasteners, manufactured by different manufacturers (SFS INTEC or LR ETANCO), depend on the

substrate:

Profiled metal decking substrate (standard)

• screw IR2 4.8xL + plate IR 82x40 (manufacturer SFS INTEC)

• screw IR2S 4.8xL + plate IR 82x40 (manufacturer SFS INTEC)

• screw EHBDF2C 4.8xL + plate 82x40R DF (manufacturer LR ETANCO)

• screw EVDF2C 4.8xL + plate 82x40R DF (manufacturer LR ETANCO)

• screw EVDF2C 4.8xL + plate 82x40R SC (manufacturer LR ETANCO)

• screw VMS2C 4.8xL + plate 82x40R DF (manufacturer LR ETANCO)

• screw EVF2C 4.8xL + plate 82x40 R DF (manufacturer LR ETANCO)

• screw EVF2C 4.8xL + plate 82x40R SC (manufacturer LR ETANCO)

• screw ISODRILL TT + plate Etancoplast T80x40 (manufacturer LR ETANCO)

• screw EGB2C 4.8XL + plate Etancoplast T80x40 (manufacturer LR ETANCO)

• screw ISODRILL TT + plate 82x40R DF (manufacturer LR ETANCO)

• screw ISODRILL TH DF + plate 82x40R DF (manufacturer LR ETANCO)


Page 4 of 21 of European Technical Approval no. ETA-06/0158

Perforated Profiled metal decking substrate (acoustic)

• screw IFP2 6.7xL + plate IRP 82x40 (manufacturer SFS INTEC)

• screw TPR 6,3xL + IRD 82x40 (manufacturer SFS INTEC)

• screw FASTOVIS 3036 TF DF + plate 82x40R DF (manufacturer LR ETANCO)

• rivet PER/RER + 82x40R DF (manufacturer LR ETANCO)

Concrete substrate

• screw TI 6,3xL + plate IRD 82x40 (manufacturer SFS INTEC)

• nail DT 6,3xL + plate IRD 82x40 (manufacturer SFS INTEC)

• screw TI 6,3xL + plate IF/IG C 82x40 (manufacturer SFS INTEC)

• screw BETOFAST TH 3C + plate 82x40R (manufacturer ETANCO)

• screw BETOFAST TH DF 3C + plate 82x40R (manufacturer ETANCO)

• screw BETOFAST TT 2C + plastic sleeve ETANCOPLAST T80x40 (manufacturer ETANCO)

• nail NAILFIX CH + plate 82x40 R SC (manufacturer LR ETANCO)

Lightweight concrete substrate

• screw IGR S 8,0xL + plate IG8 C 82x40 (manufacturer SFS INTEC)

• screw MULTIFAST TB INOX A2 + 80x40R (manufacturer LR ETANCO)

Wood substrate

• screw IG 6,0xL + plate IRD 82x40 (manufacturer SFS INTEC)

• screw IWT 5,0xL + plate IRC/W 82x40 (manufacturer SFS INTEC)

• screw EVF2C 4.8xL + plate 82x40R SC (manufacturer LR ETANCO)

• screw EVDF2C 4.8xL + plate 82x40R DF (manufacturer LR ETANCO)

• screw EVDF 2C 4.8xL + plate 82x40R SC (manufacturer LR ETANCO)

• screw MULTIFAST TF + plate 80x40R (manufacturer LR ETANCO)

All the fasteners conform to the specifications of the ETAG 006 (see Not1).

The flexible membranes and the fasteners are commercialised in separate transactions and assembled on site.

The means of fastening are presented in annex 4.

The insulation material is fastened in the centre of each insulation panel with fasteners. The number of fasteners

or fasteners and the type are defined in the national provisions and /or product certificates for the insulation.

Note In addition to the list of fasteners, other fasteners may also be used unless they are covered by a valid

ETA and with rectangular plate with dimensions of 82X40 (as example, the fasteners of the ETA 08/0285 from

AFAST BV – Guardian Fastening System- with plate size 82X40)

Adhesive

DERBIGUM SP 3 FR (and DERBICOLOR FR ) is glued to DERBICOAT HP 2,5 with DERBIBOND cold

adhesive, which is a bituminous adhesive

Insulation

The wind uplift test has been performed on a mineral wool substrate with compressibility at 10% of 50 kPa and

point load behaviour of 120 kPa, deformation 5 mm, and the values are valid for other insulation materials with

the same thickness (0 mm – 350 mm) and equal or higher compressibility and point load behaviour. The

insulation material is not part of the kit. The use of the insulation board as substrate for mechanically fastened

roof waterproofing is defined in national provisions.

Intended use

DERBIGUM SP 3 FR on DERBICOAT HP 2,5 and DERBICOLOR 4 FR on DERBICOAT HP 2,5 double layer

roof waterproofing kit is used for waterproof covering for sloped or flat roofs. The kits are specially designed for


mechanical fastening.

Page 5 of 21 of European Technical Approval no. ETA-06/0158

The load bearing elements are made from steel, concrete, lightweight concrete or wood. The MEFAWAME can be

installed directly on the substrate or on an insulation material. In the latter case the insulation material shall comply

with the requirements mentioned above.

In the manufacturer's technical dossier (MTD) 4 to this European technical approval (ETA) the manufacturer has

given information concerning the substrate, which the roof waterproofing is suitable for and on how these

substrates shall be pre-treated.

Assumed working life

The tests and assessment have been based on the assumption that the working life of DERBIGUM SP 3 FR on

DERBICOAT HP 2,5 and DERBICOLOR 4 FR on DERBICOAT HP 2,5 double layer roof waterproofing kits for the

above described intended use is at least 10 years. This cannot be understood as a guarantee given by Imperbel S.A,

subsidiary companies and distributors or ETA-Danmark A/S.

2 Characteristics of product and assessment

Characteristics of products and systems

The components of the roof waterproofing kit show the characteristic values with respect to the permissible

tolerances which are stated in the MTD to this ETA.

The chemical composition and the characteristic property values of the components of the kit and the

manufacturing methods are confidential and deposited with ETA-Danmark A/S.

The ETA is issued for the kit on the basis of the product composition deposited with ETA-Danmark A/S.

Changes to the components of the kit or in the production process of the components, which could result in the

production process and/or the properties of the product deposited being incorrect should be notified to ETA-

Danmark A/S before the changes are introduced. ETA-Danmark A/S will decide whether or not such changes

affect the ETA and consequently the validity of the CE marking on the basis of the ETA and if so whether further

assessment/alterations to the ETA shall be necessary.

The performances of the membranes, the fasteners and the kits are presented in Annexes 1, 2 and 3.

Methods of verification

Assessment of the fitness of the roof waterproofing for the intended use with regard to the essential requirements

N° 2 to N° 4 was performed following the "Guideline for European Technical Approval of systems of

mechanically fastened flexible roof waterproofing membranes" (ETAG 006).

According to the manufacturer's declaration the roof waterproofing taking account of the EU database 5 does not

contain any dangerous or forbidden substances.

4 The manufacturer's technical dossier (MTD) comprises all information necessary for the production and the processing of the

product as well as for the repair of the roof waterproofing made from that. It was checked by ETA-Danmark A/S and it was found

to be in accordance with the conditions stated in the approval and the characteristic values determined during the approval testing.

5) In accordance with http://europa.eu.int-/comm/enterprise/construction/internal/dangsub/dangmain.htm In addition to the specific

clauses relating to dangerous substances contained in this European Technical Approval, there may be other requirements

applicable to the products falling within its scope (e.g. transposed European legislation and national laws, regulations and

administrative provisions). In order to meet the provisions of the EU Construction Products Directive, these requirements need also

to be complied with, when and where they apply.


Page 6 of 21 of European Technical Approval no. ETA-06/0158

3 Attestation of Conformity and CE marking

3.1 Attestation of Conformity system

The attestation of conformity applied to this product specified by the European Commission in Mandate Construct

98/143EC of February 1998, Annex 3 is System 2+ and provides:

a) Tasks for the manufacturer:

(1) Initial type testing of the product

(2) Factory production control,

b) Tasks for the notified body:

(1) Initial inspection of factory and of factory production control (FPC)

(2) Continuous surveillance, assessment and approval of factory production control

3.2 Responsibilities

3.2.1 Tasks for the manufacturer

3.2.1.1 Factory production control.

The manufacturer of the membrane has a factory production control system in the plant and exercises permanent

internal control of production. All the elements, requirements and provisions adopted by the manufacturer are

documented in a systematic manner in the form of written policies and procedures. This production control system

ensures that the product is in conformity with the European Technical Approval.

The manufacturers of the fasteners have a factory production control system in the plant and exercises permanent

internal control of production. All the elements, requirements and provisions adopted by the manufacturer are

documented in a systematic manner in the form of written policies and procedures. This production control system

ensures that the product is in conformity with the European Technical Approval.

The manufacturer of membranes and fasteners may only use raw materials or components stated in the technical

documentation of this European technical approval.

The factory production control shall be in accordance with the "Control Plan” relating to the European technical

approval ETA - which is part of the technical documentation of this European technical approval. The "Control

Plan" is laid down in the context of the factory production control system operated by the manufacturer and

deposited at ETA-Danmark A/S. 6

The results of factory production control shall be recorded and evaluated in accordance with the provisions of the

"Control Plan".

The results of factory production control are recorded and evaluated. The records include at least the following

information:

• Designation of the product, basic material and components;

• Type of control or testing;

• Date of manufacture of the product and date of testing of the product or basic material and components;

• Result of control and testing and, if appropriate, comparison with requirements;

• Signature of person responsible for factory production control.

The records shall be presented to ETA-Danmark A/S on request

3.2.1.2 Initial type testing of the product

6 The "control plan" is a confidential part of the European technical approval and only handed over to the approved body or bodies

involved in the procedure of attestation of conformity. See section 3.2.2.


Page 7 of 21 of European Technical Approval no. ETA-06/0158

For initial type-testing the results of the tests performed as part of the assessment for the European Technical

Approval shall be used unless there are changes in the production line or plant. In such cases the necessary initial type

testing has to be agreed between ETA-Danmark A/S and the manufacturer.

3.2.1.3 Other tasks of the manufacturer

The manufacturer shall, on the basis of a contract, involve a body which is notified for the tasks referred to in section

3, in the field of the product in order to undertake the actions laid down in section 3.2.2. For this purpose, the control

plan referred to in section 3.2.2 shall be handed over by the manufacturer to the notified body involved.

3.2.2 Tasks of notified bodies

3.2.2.1 Initial inspection of factory and production control.

ETA-Danmark A/S ascertains that, in accordance with the MTD, factory conditions and production control allow

the manufacturer to ensure the consistency and homogeneity of the manufactured product and its traceability,

thus guaranteeing that the final characteristics of the product are those indicated in chapter 2.

3.2.2.2 Continuous surveillance, assessment and approval of Factory Production Control

The Notified Body shall visit the factory of flexible membranes at least once a year.

Surveillance of the manufacturing processes shall include:

• Checking the documentation of factory production control, to ensure continuing compliance with the

provisions of the ETA,

• Identification of changes by comparing data obtained during the initial inspection or during the last

inspection.

In the event the ETA provisions are not complied with, the certificate of conformity shall be withdrawn and

ETA-Danmark A/S will be informed without delay.

3.3 CE Marking

The CE marking shall be affixed on the kit, components itself/themselves, an attached label, the packaging, or the

accompanying commercial document.

The required information to accompany the symbol ‘’CE’’ is:

• name or identifying name of the producer

• number of the notified body

• last two digits of the year in which the CE marking was affixed

• Number of the certificate of conformity of the Factory Production Control (System 2+)

• number of the ETA

ETAG 006

The components shall be marked as belonging to the kit.


Page 8 of 21 of European Technical Approval no. ETA-06/0158

4 Assumptions under which the fitness of the product for the intended use was favourably

assessed

4.1 Installation and design

Annex 4 contains detailed information on installation and design. The information comprises the following:

Principle sketches:

• type of mechanical fastening of membranes

• type of arranging of fasteners at upstands and penetrations

Membrane:

Seam overlap according to detailing

Fastening:

Design of fastener spacing and areas according to national requirements

Spacing of fasteners (according to kind of fastening)

Design of perimeter and edge fixation

Fastening to supporting construction

Design principles of up-stands and flashings

Design principles of penetrations fastening of installed parts/units according to national requirements

The flexible membranes manufacturer’s installation guide forms part of this ETA.

The design of the roof intended to be covered by the mechanically fastened roof waterproofing system should

take account of the following factors:

• Dead and imposed loads

• Design wind pressure

• Structural strength, stiffness and deflection limits

• Attachment of the roof deck to the structural framing

• Provision of insulation

• Assessment of condensation risk and provision of vapour control layers

• Sound insulation

• Fire precautions

• Roof attachments, fixtures and penetrations

• Falls and drainage

• Means of access for inspection and maintenance

4.2 Substrates

The substrate onto which the waterproofing kit is to be laid should be sufficiently rigid, dense, and dimensionally

stable to support the system (membrane + insulation). Its nature will depend on the type of roof selected (warm

deck, cold deck or inverted) and in turn will have a direct influence on the method of attachment.

In order to support the loads imposed by traffic, insulation materials for use in warm decks should be capable of

resisting permanent deformation or damage when subjected to concentrated loads. They should have a dust-free

surface and sufficient laminar strength to resist with a margin of safety and stress imposed by wind uplift forces.


Page 9 of 21 of European Technical Approval no. ETA-06/0158

It shall be ensured that the insulation material on site has a 10% compression of at least 50kPa and a point load

behaviour of 120 kPa, deformation 5 mm. The use of the insulation board as substrate for mechanically fastened

roof waterproofing is defined in national provisions.

4.3 Flexible membranes manufacturer’s responsibilities

It is the manufacturer's responsibility to make sure that all those who use the kit are appropriately informed about

the specific conditions according to sections 1, 2, 4, and 5 including the annexes to this ETA and the not

confidential parts of the MTD to this ETA.

5 Recommendations

5.1 Packaging, transport and storage

This product is neither toxic nor inflammable, so it is not necessary to follow any safety instructions for transport

and handling.

Rolls must always be stored vertically.

The product must keep away from any source of heat, sparks, flame, etc.

5.2 Maintenance and repair of the works

The assessment of the fitness for use is based on the assumption that a normal maintenance of the system is

performed.

This maintenance shall include:

• inspections of the roof at regular interval, e.g. twice a year. This inspection should include:

o cleaning of downpipes and leaf filters

o removal of stones, branches and leafs

o inspection of flashings along the edge of the roof, chimneys, drains and roof lights

o removal of organic growths such as vines

• Flashings to chimneys, roof edges, skylights, caps, drains etc. should be inspected every 5 years and corrected

or replaced if necessary

• Abrasion and minor impact damage shall be repaired.

When replacing components they shall be approved by the manufacturer and covered by the ETA.

Thomas Bruun

Manager, ETA-Danmark A/S


Page 10 of 21 of European Technical Approval no. ETA-06/0158

Annex 1

Characteristics of membranes (manufacturers declared values)

MEMBRANE Expression of result DERBIGUM SP3*) DERBICOAT HP 2,5 Reference

Reaction to fire Euroclass Euroclass E Euroclass F EN 13501-1

Peel resistance of joint MDV(±20%) 60 N/50 mm 60 N/50 mm EN 12316-1

Shear resistance of joint MDV (±10%) 560 N/50 mm 500 N/50 mm EN 12317-1

Tear resistance (nail) Long

MDV(±20%)

200 N

150 N

EN 12310-1

Trans

MDV(±20%)

200 N

150 N

Cold bending MLV -15 °C -15 °C EN 1109

Water pressure No leakage Pass Pass EN 1928

Tensile properties Long

(MDV ± 20 %)

700 N/50 mm 550 N/50 mm EN 12311-1

Trans

650 N/50 mm 500 N/50 mm

Elongation

(MDV ± 20 %)

Long

(MDV ± 15)

45 %

30 %

Trans

(MDV ± 15)

45 %

30 %

Static loading resistance MLV

20 kg

20 kg

EN 12730

Impact loading resistance MLV

Peel resistance after After heat

ageing

After water:

Shear resistance after After heat

ageing

Cold bending After heat

After UV

Dimensional stability Long

MLV

Trans

MLV

∅ 20 mm

Max ∆ 20 %

∅ 20 mm

Max ∆ 20 %

EN 12691

EN 12316-1

Max ∆ 20 % Max ∆ 20 %

Max ∆ 20 % Max ∆ 20 % EN 12317-1

Max ∆ 15 °C

Max ∆ 15 °C

0,2 %

0,2 %

Max ∆ 15 °C

Max ∆ 15 °C

0,3 %

0,3 %

EN 1109

EN 1107-1

*) It has been shown by tear test and tensile test that the membrane DERBICOLOR 4 has higher values than

DERBIGUM SP 3. Hence, according to the small scale test concept the kit consisting of DERBICOLOR 4 on

DERBICOAT HP 2,5 with DERBIBOND cold adhesive and fasteners as described in 1.1 can be considered fit for the

intended use with the same performance values as mentioned above.


Type

ETAG Paragraph

IR2 4,8 × L + IR 82 × 40

SFS INTEC

IR2S 4,8 × L + IR 82 × 40

SFS INTEC

EHBDF2C 4.8xL + 82x40R DF

LR ETANCO

EVDF2C 4.8xL + 82x40R DF

LR ETANCO

EVDF2C 4.8xL + 82x40R SC

LR ETANCO

VMS2C 4.8xL + 82x40R DF

LR ETANCO

EVF2C 4.8xL + 82x40R SC

LR ETANCO

EVF2C 4.8xL + 82x40R DF

LR ETANCO

ISODRILL TT + Etancoplast

T80x40

LR ETANCO

EGB2C 4.8xL + Etancoplast

T80x40

LR ETANCO

ISODRILL TT + 82x40 R DF

LR ETANCO

ISODRILL TH DF + 82x40 R DF

LR ETANCO

Page 11 of 21 of European Technical Approval no. ETA-06/0158

5.3.4.1

Axial

loading

test

(N)

Annex 2

Characteristics of fasteners

5.3.4.2

Unwinding

5.3.4.3

Mechanical

resistance of

sleeve

5.3.7.1

Resistance to

corrosion of

metallic

fastenings,

15 Kesternich

cycles

5.3.7.2

Mechanical

resistance after

heat ageing of

plastic

fastenings

Profiled steel deck

1450 Pass Not relevant Pass (


Type

Page 12 of 21 of European Technical Approval no. ETA-06/0158

ETAG Paragraph

IFP2 6,7 × L + IRP 82 × 40

SFS INTEC

TPR 6,3 × L + IRD 82 × 40

SFS INTEC

FASTOVIS 3036 TF + 82x40R DF

LR ETANCO

FASTOVIS 3036 TF DF + 82x40R DF

LR ETANCO

Rivet RER/PER + 82x40 R DF

LR ETANCO

TI 6,3 × L + IRD 82 × 40

SFS INTEC

TI 6,3 × L + IF/IG C 82 × 40

SFS INTEC

DT 6,3 × L + IRD 82 × 40

SFS INTEC

BETOFAST TH 3C + 82x40R

LR ETANCO

BETOFAST TH DF 3C + 82x40R

LR ETANCO

NAILFIX CH + 82x40 R SC

LR ETANCO

BETOFAST TT 2C+ ETANCOPLAST

T80x40

LR ETANCO

IGR S 8,0 × L + IG8 C 82 × 40

SFS INTEC

MULTIFAST TB INOX + 82x40R

LR ETANCO

IG 6,0 × L + IRD 82 × 40

SFS INTEC

IWT 5 × L + IRC/W 82 × 40

SFS INTEC

MULTIFAST TF + 82x40R

LR ETANCO

EVF2C 4.8xL + 82x40R SC

LR ETANCO

EVDF2C 4.8xL + 82x40R DF

LR ETANCO

EVDF2C 4.8xL + 82x40R SC

LR ETANCO

5.3.4.1

Axial

loading

test

(N)

5.3.4.2

Unwinding

5.3.4.3

Mechanical

resistance of

sleeve

5.3.7.1

Resistance to

corrosion of

metallic

fastenings,

15 Kesternich

cycles

5.3.7.2

Mechanical

resistance after

heat ageing of

plastic

fastenings

Perforated profiled steel deck

2600 Pass Not relevant Pass (


Material properties of the screws and fasteners:

Page 13 of 21 of European Technical Approval no. ETA-06/0158

Screws

• IR2 4.8xL: Hardened carbon steel screw. Double-thread, with a diameter of 4,8 mm, length L and with a 8 mm

hexagonal head. Durocoat corrosion protection.

• IR2S 4,8xL: Austenitic stainless steel A4 screw. Diameter of 4,8 mm, length L and with a 8 mm hexagon head.

• IFP2 6,7xL: Hardened carbon steel screw. Double-thread, with a diameter of 6,7 mm, length L and with a 11 mm

diameter flat head. Durocoat corrosion protection.

• IWT 5xL: Hardened carbon steel screw. Diameter of 5 mm, length L and with a 9.5 mm diameter flat head.

Duracoat corrosion protection.

• IG 6xL: Hardened carbon steel screw. Diameter of 6 mm, length L and with a 8 mm diameter flat head. Duracoat

corrosion protection.

• IGR-S 8,0xL: Austenitic stainless steel A2 screw. Diameter of 8,0 mm, length L and with a 12 mm countersunk

head.

• TI 6,3xL: Hardened carbon steel screw. Diameter of 6,3 mm, length L and with a 8 mm hexagon head. Duracoat

corrosion protection.

• DT 6xL: Hardened carbon steel screw. Diameter of 6,3 mm, length L

• IG 6xL: Hardened carbon steel screw. Diameter of 6 mm, length L and with a 8 mm diameter flat head. Duracoat

corrosion protection.

• EVF 2C 4.8xL: hardened carbon steel screw. Diameter of 4,8 mm, length L and with a 12 mm circular head.

Supracoat corrosion protection.

• EVDF 2C 4.8xL: hardened carbon steel screws with double-thread under head, with a diameter of 4,8 mm, length L

and with a 12 mm circular head. Supracoat corrosion protection.

• EVBDF 2C: hardened carbon steel screws with double-thread under head, with a diameter of 4,8 mm, length L and

with a 12 mm circular head. Supracoat corrosion protection.

• EHBDF 2C 4.8xL: hardened carbon steel screw with double-thread under head, with a diameter of 4,8 mm, length

L and with a 8 mm hexagonal head. Supracoat corrosion protection.

• VMS 2C 4.8xL: hardened carbon steel screw. Diameter of 4,8 mm, length L and with a 8.5 mm circular head.

Supracoat corrosion protection.

• EGB 2C 4.8xL: hardened carbon steel screw. Diameter of 4,8 mm, length L and with a 12 mm circular head.

Supracoat corrosion protection.

• ISODRILL TT: stainless steel screw. Diameter of 4,8 mm, length L and with a 8,5 mm circular head. A4 (1.4404)

Stainless steel.

• ISODRILL TH DF: Stainless steel screw with double-thread under head, with a diameter of 4,8 mm, length L and

with a 8 mm hexagonal head. A4 (1.4304) stainless steel.

• FASTOVIS 3036 TF 2C : hardened carbon steel screw. Diameter of 6,5 mm, length L and with a 11 mm

countersunk head. Supracoat corrosion protection.

• FASTOVIS 3036 TF DF 2C : hardened carbon steel screws with double-thread under head, with a diameter of 6,5

mm, length L and with a 11 mm countersunk head. Supracoat corrosion protection.

• PER and RER : Aluminium rivet. Diameter of 4,8 mm, length L and with a 10 mm circular head.

• TPR 6,3xL : Aluminium rivet. Diameter of 6,3 mm, length L.

• BETOFAST TH 3C: hardened carbon steel screw, with a diameter of 6,6 mm, length L and with a 8 mm hexagonal

head. Supracoat corrosion protection.

• BETOFAST TH DF 3C : hardened carbon steel screw with double-thread under head, with a diameter of 6,6 mm,

length L and with a 8 mm hexagonal head. Supracoat corrosion protection.

• BETOFAST TT 2C: hardened carbon steel screw. Diameter of 4,8 mm, length L and with a 8,5 mm circular head.

Supracoat corrosion protection

• NAILFIX CH: carbon steel nail diameter 4,8 mm, length L with a 10 circular head. Hot dip galvanized corrosion

protection.

• MULTIFAST TB INOX A2 : Stainless steel screw. Diameter of 6 mm, length L and with a 12 mm circular head.

A2 (1.4301) stainless steel.

• MULTIFAST TF : Stainless steel screw. Diameter of 6 mm, length L and with a 11 mm countersunk head. A2

(1.4301) stainless steel.


Page 14 of 21 of European Technical Approval no. ETA-06/0158

Washers

• 82x40 R DF: reinforced steel plate 82x40 mm, thickness 10/10e mm with punched inside cone. Hole Ø 5,1 mm.

Aluzinc AZ 150 protection

• 82x40 R: reinforced steel plate 82x40 mm, thickness 10/10e with punched inside cone. Hole Ø 6 mm. Aluzinc AZ

150 protection

• 82x40 R SC: reinforced steel plate 82x40 mm, thickness 10/10e mm. Hole Ø 6,4 mm. Aluzinc AZ 150 protection

• IR 82x40, IRD 82x40, IRP 82x40, IF/IG C 82x40, IG8 C 82x40, IRC/W 82x40: steel plates with aluzinc

protection, dimension 82x40 mm, thickness 1.00 mm

• Etancoplast T 80x40: Ø 73x40 plastic plate with shaft

Note In addition to the list of fasteners, other fasteners may also be used unless they are covered by a valid ETA and

with rectangular plate with dimensions of 82X40 (as example, the fasteners of the ETA 08/0285 from AFAST BV –

Guardian Fastening System- with plate size 82X40)


Page 15 of 21 of European Technical Approval no. ETA-06/0158

Annex 3

Characteristics of the kit

Membrane Fastener Wadm External fire performance

DERBIGUM SP 3 FR on See list in 1.1 380 N/Fastener No performance

DERBICOAT HP 2,5

determined

DERBICOLOR 4 FR on See list in 1.1 380 N/Fastener No performance

DERBICOAT HP 2,5

determined

Wadm was determined with a fastener with axial loading resistance Roc = 1458 N,

To determine Wadm for other combinations (other substrate and other fastener) the following formula and conditions

apply:

If Rnc ≥ Roc then Wadm, nc = Wadm, oc

If Rnc < Roc then Wadm, nc = (Rnc/Roc) × Wadm,oc

The application of the full scale test results for systems with other fasteners (Rnc) and/or substrates according to annex 2

of this ETA, a separate ETA or Fastener PASS issued on the basis of ETAG 006, is possible if:

• The plates are protected against corrosion;

• The minimal thickness of the metallic plates is:

o 0.75 mm, if they are ribbed,

o 1,00 mm, if they are flat.

In the new system, the use of plates that are different from those in the reference system is possible under the following

conditions:

• The steel plates are permitted with their resistance R determined in the whole system,

• The metal grades and thicknesses are higher or equal to those of reference ones,

• The dimensions of washers comply with the conditions in the following Table.

Round washers

Plates “nc”

Square, rectangular or oblong

Plates “oc”

washers

Round, Ø test Ø ≥ Ø test Width and length larger than or

equal to the one tested

Square, rectangular or

Ø ≥ diagonal of washer tested Dimensions larger than or equal

oblong

oc = original combination (tested)

nc = new combination

to the one tested

The fasteners have to be in conformity with the specifications given in section 1.1.2 and annex 2 of this ETA, an ETA

delivered on the basis on the ETAG 006 or a FASTENER PASS FOR MEFAWAME ETA – Intermediate evaluation in

compliance with the European Technical Approval Guideline n°006.


Page 16 of 21 of European Technical Approval no. ETA-06/0158

Annex 4

Design and installation details

Design and installation

The suitability of this kit is valid only if the installation is carried out in accordance with the manufacturer’s

instructions.

The kit may be laid in conditions normal to roofing work and must not be laid in rain, snow or heavy fog, nor if the

temperature falls below 2°C, unless specific precautions have been taken.

Insulation

The possibly laid insulation layer is constituted by thermal insulation boards appropriate for the use considered (see

ETAG 006 chapter 5.4 and 6.4). They are loose laid on the possibly present vapour barrier. The mechanical fastening

of the waterproofing system fastens the movement of the underlying layers to the deck. In some case (in function of

insulation boards size and national standards) the insulation boards need to be independently fixed by 1 or 2 fasteners

per boards that are not counted for in the density calculation for the mechanically fixed waterproofing. The insulation

layer and the vapour barrier are realized according to the national standards.

Laying and overlaps of the first layer

The first layer, which consists of an underlayer DERBICOAT HP or DERBICOAT ARTIC or DERBIGUM SP 3 FR, is

aligned and unrolled in contact of the substrate. The roll has a nominal width of 110 or 55 cm,

The layer is then mechanically fixed with the fasteners and washers under the longitudinal overlaps (cfr Figure 1). The

next sheet is then aligned on the first with a longitudinal overlap of 120 mm welded. The end overlaps are 100 mm.

Figure 1 : longitudinal overlap with mechanical fastener

Overlaps must be then welded over their whole widths; the edges are then correctly pressed down. A small quantity of

bitumen must be exuded from the overlap joint.


Page 17 of 21 of European Technical Approval no. ETA-06/0158

Fasteners

The system is mechanically fastened in the overlaps by using prescribed fasteners (see chapter above). The position of

the fastener in the overlap is shown on the figure 1 above.

The calculation of the distance between fasteners and the number of fasteners per square meters on the different roof

zones are determined according to the national Standards.

The distance E between fasteners is determined by the formula E ≤ 1 / (D * Lr) with the following restrictive

conditions:

- Minimal distance between fasteners = 18 cm

- Maximal distance between fasteners = 34 cm (or in accordance with national standards).

With

- D = minimal density of fasteners = Dp / Wadm of the “kit”

- Lr = distance between fasteners rows (= width of the waterproofing sheet – width of the overlap; 97 cm for a

110 cm sheet, 42 cm for a 55 cm sheet). Figure 4 below gives Lr values for several sheet laying.

- Dp = Wind air pressure in the different roof zones (central, edge, corner,…) according to the national standards.

If the calculated distance with a 110 cm sheet is E < 18 cm it is needed to adapt the laying of the system by either :

- using sheets of 55 cm in width with fasteners in the longitudinal overlaps. See figure 2 below.

- laying additional fasteners in a row at the middle of the sheet. Those fasteners are then recovered by a bridging

stroke of width 20 cm in DERBIGUM fully torched. See figure 3 below.

- Enlarge the width of the longitudinal overlaps > 130 mm.

Figure 2 : half strokes Figure 3 : bridging strokes


Page 18 of 21 of European Technical Approval no. ETA-06/0158

Figure 4 : Distance between rows of fasteners


Laying and overlaps of the second layer

Page 19 of 21 of European Technical Approval no. ETA-06/0158

The second layer, preferably laid in the same direction with an offset of a half width, consists of a cap sheet in

DERBIGUM SP 3 FR or DERBICOLOR 4 FR , fully bonded by torching or fully bonded in cold adhesive

DERBIBOND (± 1 kg/m²). The DERBIGUM SP 3 FR may also be fully bonded in cold adhesive DERBIBOND (±

1kg/m²).

Longitudinal overlaps of the cap sheet are welded over the whole width of 100 mm, the edges are then pressed down

(for instance with a pressure roller). Transverse overlaps are 150 mm. A small quantity of bitumen must be exuded

from the overlap joint. The crossing of the overlaps is done with a T-joint. The edge of the corner is cut at 45°

(cfr Figure 5).

Figure 5 : T-joint

Figure 2 : Twin layer waterproofing

1. First waterproofing layer mechanically fixed

2. Mechanical fasteners in the longitudinal overlaps

3. Longitudinal overlaps (120 mm) welded

4. Second waterproofing layer total bonded by torching or total bonded in cold adhesive DERBIBOND

5. Longitudinal overlaps (100 mm) welded (transverse overlaps 150 mm).

E Distance between mechanical fasteners in a row

For the realization details: see national recommendations


Details

Upstands

Page 20 of 21 of European Technical Approval no. ETA-06/0158

The waterproofing upstand on vertical surfaces is carried out according to the details 7 and 8. The realization detail

(size of strokes, minimal upstand height) and the finishing at the top of the upstand (flashing, finishing profile, etc…)

are in accordance with national recommendations.

Examples of layout for the waterproofing upstand

Figure 3 : Upstand with upperlying

reinforcing strip

1. Substrate of the waterproofing sheet

2. First waterproofing layer mechanically fixed

3. Second waterproofing layer laid in total adhesion

4. Reinforcing strip fully torched

5. Waterproofing upstand fully torched

6. Finishing at the end of the waterproofing

h minimum height : see national recommendations

For the realization details: see national recommendations

Figure 4 : Upstand with underlying

reinforcing strip

Water outlet

A recess is carried in the substrate or in the insulation board (in case of a warm roof buildup) around the water outlet,

with a thickness difference of min 10 mm. See detail here below.

Figure 5 : water outlet with fastened flange


Page 21 of 21 of European Technical Approval no. ETA-06/0158

1. Recess in the waterproofing substrate

2. Reinforcing piece in DERBIGUM

3. Flange of the water outlet mechanically fixed at the corners

4. First waterproofing layer mechanically fixed

5. Second waterproofing layer laid in total adhesion

6. Grate

a minimum width of the flange : see national recommendations

For the realization details: see national recommendations

Penetration fastening

The waterproofing detail on punctual penetration are carried as shown in Figure 10.

Figure 6 : Penetration fastening example

1. Substrate

2. First waterproofing layer mechanically fixed

3. Second waterproofing layer laid in total adhesion

4. Sleeve of the penetration (duct, tube, roof vent etc…) with flange mechanically fixed at the corners

5. Fastener of the flange

6. Waterproofing mechanically fixed

7. Flashing

a minimum width of the flange : see national recommendations

For the realization details: see national recommendations

More magazines by this user