ISK 77 / SPK 77 - ASO Safety
ISK 77 / SPK 77 - ASO Safety
ISK 77 / SPK 77 - ASO Safety
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
English<br />
24<br />
<strong>ISK</strong> <strong>77</strong> / <strong>SPK</strong> <strong>77</strong> Inductive <strong>Safety</strong> Relay<br />
6.1.4 Variant E<br />
Control output as high-side switch and low-side switch<br />
High<br />
Side<br />
Switch<br />
+<br />
OUT_H<br />
•<br />
•<br />
•<br />
Alternative or parallel use of the outputs possible<br />
No galvanic separation<br />
Cat. 3 (internal testing)<br />
Low<br />
Side<br />
Switch<br />
_<br />
6.1.5 Variant W<br />
Control output as 8k2 resistance output<br />
resistor<br />
8k2<br />
While in the idle state, the resistance between the two connections is approximatel�� 8.2k kW. If actuation<br />
of the safet�� edges is reported, the resistance is less than 100 W. In the event of a fault or interruption<br />
of safet�� edges, the resistance is greater than 100 kW.<br />
6.1.6 Variant R<br />
Control output via semiconductor rela��<br />
Semiconductor<br />
rela��<br />
In order to perform an externall�� requested test in accordance with categor�� 2, this variant is alwa��s<br />
combined with variant T (test).<br />
6.1.7 Variant T<br />
An externall�� requested test can be performed via three connection cables. The polarit�� and test<br />
request are set according to the configuration of the connection cable with voltage.<br />
6.1.8 Variant D<br />
OUT_L<br />
R 11<br />
R 12<br />
13<br />
14<br />
• DC suppl��<br />
The safet�� rela�� is equipped with a displa��.<br />
• Galvanic separation<br />
• Cat. 3 (internal testing)<br />
• Adaptation to the controller ma�� be necessar��.<br />
• AC / DC suppl��<br />
• Galvanic separation<br />
• Onl�� Cat. 2 possible<br />
• AC / DC suppl��