6. Automatic Water Entry<br />

The AEA system (Automatic Water Entry) is for checking the boiler level. It is composed of:<br />

• sensor inserted in the boiler (1), composed of a stainless steel rod;<br />

• control unit (2) standard on SAE-SME machines, electronic level regulator on other<br />

versions (3);<br />

• hydraulic circuit with a solenoid valve controlled by the regulator.<br />

The electronic control unit controls the level of water in the boiler. When the level of water<br />

in the boiler drops, the contact with the probe is interrupted. The control unit sends and<br />

impulse to the entry solenoid valve (1) and to the motor pump (2), which act to restore<br />

the normal level of water in the boiler.<br />

To avoid possible flooding due to machine malfunctions or leaks in the hydraulic circuit, the<br />

electronic control unit includes a timing device that cuts off automatic filling after a certain<br />

time (roughly 30 seconds). The LED (4) located on the front of the machine body comes<br />

on to indicate activation of this system. During the installation of machines with three or<br />

four groups the initial water filling time may exceed the established time limit. In this event,<br />

just switch the machine off and then back on to restore normal operating conditions.<br />

WARNING<br />

Always check the level of the water in the boiler by means of the level-check<br />

window placed on the front of the machine.<br />

7. VOLUMETRIC DOSING<br />

The volumetric dosing device installed on the SAE-SME electronic machines serves the<br />

purpose of measuring the quantity of water sent to the group of espresso delivery.<br />

The dosing device generates an electrical impulse which is sent to the electronic control<br />

unit. This impulse is read by the control unit and memorized during the programming of<br />

the dose.<br />

The flashing of the LED (5) indicates that the electrical impulse has been sent from the<br />

dosing device to the control unit.<br />

8. PRESSURE SWITCH<br />

The pressure switch makes it possible to control boiler pressure by activating or bypassing<br />

the heating element in the boiler.<br />

Any calibration of the pressure switch which may be required can be carried out with the machine<br />

in operation by means of the screw (6) located on the body of the component.<br />

WARNING<br />

The internal contacts of the pressure switch may be subject to oxidization. It<br />

is recommended to periodically clean the contacts with anti-oxidant spray.<br />