6. Automatic Water Entry<br />
The AEA system (Automatic Water Entry) is for checking the boiler level. It is composed of:<br />
• sensor inserted in the boiler (1), composed of a stainless steel rod;<br />
• control unit (2) standard on SAE-SME machines, electronic level regulator on other<br />
versions (3);<br />
• hydraulic circuit with a solenoid valve controlled by the regulator.<br />
The electronic control unit controls the level of water in the boiler. When the level of water<br />
in the boiler drops, the contact with the probe is interrupted. The control unit sends and<br />
impulse to the entry solenoid valve (1) and to the motor pump (2), which act to restore<br />
the normal level of water in the boiler.<br />
To avoid possible flooding due to machine malfunctions or leaks in the hydraulic circuit, the<br />
electronic control unit includes a timing device that cuts off automatic filling after a certain<br />
time (roughly 30 seconds). The LED (4) located on the front of the machine body comes<br />
on to indicate activation of this system. During the installation of machines with three or<br />
four groups the initial water filling time may exceed the established time limit. In this event,<br />
just switch the machine off and then back on to restore normal operating conditions.<br />
WARNING<br />
Always check the level of the water in the boiler by means of the level-check<br />
window placed on the front of the machine.<br />
7. VOLUMETRIC DOSING<br />
The volumetric dosing device installed on the SAE-SME electronic machines serves the<br />
purpose of measuring the quantity of water sent to the group of espresso delivery.<br />
The dosing device generates an electrical impulse which is sent to the electronic control<br />
unit. This impulse is read by the control unit and memorized during the programming of<br />
the dose.<br />
The flashing of the LED (5) indicates that the electrical impulse has been sent from the<br />
dosing device to the control unit.<br />
8. PRESSURE SWITCH<br />
The pressure switch makes it possible to control boiler pressure by activating or bypassing<br />
the heating element in the boiler.<br />
Any calibration of the pressure switch which may be required can be carried out with the machine<br />
in operation by means of the screw (6) located on the body of the component.<br />
WARNING<br />
The internal contacts of the pressure switch may be subject to oxidization. It<br />
is recommended to periodically clean the contacts with anti-oxidant spray.<br />