Views
4 years ago

Fayers-Rad-Book-WebL..

Fayers-Rad-Book-WebL..

RADIATORS 8 For maximum

RADIATORS 8 For maximum efficiency, radiators should be fixed at not less than 100mm (4”) from finished floor level. Pipe positioning guide for manual valve allow 35mm to centre pipe. For TRV valve allow 45mm to centre pipe. To prevent damage to radiator it is strongly recommended during installation to leave protective packaging on radiator by simply removing the lug protectors and pre cut tapping connection. Water Treatment It is strongly recommended on completion of the installation the system should be properly flushed and filled in accordance with the British Standard Code of Practice for the Treatment of Water in Domestic Hot Water Central Heating Systems BS 7593. Prima ® Radiators BS EN 442 tested and certified. Factory fitted top grilles and side panels. High quality finish - white enamel (RAL 9010). Installation package includes brackets, plugs, vents, bolts and wall plugs.

SINGLES P+ DOUBLES Height Width Code Watts BTUs LIST Code Watts BTUs LIST Code Watts BTUs LIST 600 PD306 508 1732 £107.94 1000 PD310 1015 3465 £185.84 300mm 1200 PD312 1217 4158 £235.61 1400 PD314 1420 4850 £265.24 2000 PD320 2029 6930 £379.78 400 PS404 281 9332 £62.70 600 PS406 422 1399 £71.12 PD406 780 2664 £130.87 800 PS408 562 1865 £81.10 PD408 1040 3551 £151.44 1000 PS410 703 2332 £100.50 PD410 1300 4439 £189.19 400mm 1200 PS412 844 2799 £122.94 PD412 1559 5327 £231.44 1400 PS414 985 3265 £143.42 PD414 1820 6215 £270.02 1600 PS416 1126 3732 £163.93 PD416 2080 7103 £308.57 1800 PS418 1266 4197 £184.41 PD418 2340 7991 £347.15 2000 PS420 1407 4664 £204.90 PD420 2600 8878 £385.72 400 PS504 342 1134 £67.42 500 PS505 428 1417 £76.64 PD505 784 2679 £134.76 600 PS506 513 1701 £85.88 PP506 753 2571 £128.47 PD506 941 3215 £148.16 700 PS507 598 1985 £90.29 PD507 1098 3750 £172.73 800 PS508 684 2268 £102.85 PP508 1003 3428 £170.65 PD508 1255 4286 £196.98 900 PS509 769 2551 £116.30 PP509 1129 3856 £191.64 PD509 1412 4821 £221.52 500mm 1000 PS510 855 2835 £127.47 PP510 1255 4284 £212.80 PD510 1569 5357 £246.07 1100 PS511 941 3119 £143.77 PP511 1380 4712 £238.40 PD511 1725 5893 £275.74 1200 PS512 1026 3402 £155.94 PP512 1506 5141 £260.40 PD512 1883 6428 £300.98 1300 PS513 1112 3685 £173.83 PD513 2039 6964 £338.11 1400 PS514 1197 3969 £181.93 PP514 1756 5998 £303.99 PD514 2196 7499 £351.16 1600 PS516 1369 4536 £207.92 PP516 2007 6855 £347.21 PD516 2510 8572 £401.31 1800 PS518 1539 5103 £233.91 PD518 2823 9643 £451.48 2000 PS520 1710 5670 £259.90 PD520 3137 10714 £501.65 400 PS604 401 1329 £73.27 PP604 580 1980 £106.96 PD604 729 2488 £127.51 500 PS605 501 1660 £84.34 PP605 725 2474 £124.17 PD605 912 3112 £145.94 600 PS606 600 1992 £89.25 PP606 869 2969 £130.74 PD606 1093 3734 £158.26 700 PS607 701 2325 £97.57 PP607 1015 3464 £152.47 PD607 1275 4356 £184.66 800 PS608 801 2656 £110.93 PP608 1160 3959 £173.87 PD608 1457 4978 £210.79 900 PS609 902 2988 £124.32 PP609 1304 4454 £195.26 PD609 1640 5600 £236.90 600mm 1000 PS610 1001 3321 £137.55 PP610 1449 4949 £217.11 PD610 1822 6222 £263.16 1100 PS611 1101 3652 £153.52 PP611 1594 5444 £243.07 PD611 2004 6844 £294.97 1200 PS612 1202 3985 £168.24 PP612 1739 5939 £265.43 PD612 2187 7466 £321.92 1300 PS613 1302 4317 £189.19 PP613 1884 6433 £298.27 PD613 2369 8089 £369.60 1400 PS614 1403 4648 £196.29 PP614 2029 6929 £309.69 PD614 2551 8712 £375.60 1500 PS615 1502 4981 £217.91 PP615 2174 7423 £341.63 PD615 2734 9334 £420.07 1600 PS616 1602 5313 £224.33 PP616 2319 7919 £353.67 PD616 2915 9956 £433.41 1800 PS618 1802 5977 £252.37 PP618 2609 8908 £398.37 PD618 3280 11200 £487.58 2000 PS620 2003 6641 £283.13 PP620 2898 9898 £442.62 PD620 3644 12444 £541.77 400 PS704 484 1604 £88.51 PD704 871 2975 £158.19 500 PS705 605 2005 £98.35 PD705 1089 3718 £180.34 700mm 600 PS706 726 2406 £104.61 PD706 1306 4462 £191.89 700 PS707 847 2807 £121.40 PD707 1524 5206 £223.62 800 PS708 968 3207 £138.07 PD708 1742 5948 £255.28 Reference outputs of a mean water temperature of 80°C and a room of 20°C. (Delta T 50°C). *All measurements are nominal The above prices exclude VAT. Due to constant improvements on products we reserve the right to alter specifications and prices at any time without prior notice. Individual Price Lists are available RADIATORS 9

Effects of Nuclear Weapons - Rad Resilient City
Sealed Rad. Sources ANG.qxd - Epsilon NDT
I-RAD Brochure - Advanced Wireless Communications
Center for Biosecurity of UPMC Rad Resilient City Project
ICTV Brand Book (pdf)
RAD-Hard DC-DC Converters deliver space-grade reliability
039 DOE 2003 Occupational Rad Exposure.pdf - National Nuclear ...
Q-SET MODULAR SCAFFOLD SYSTEM - The Green Book
SME LB 0048-Book Cover-32cmhx25cmw
iCeGS-Beacon-for-guidance-book
Download 2012 Product Guide - Devine Radiators
NGP 2011 Lite Kit Price Book - Access Hardware Supply
NGP OCT 2011 Thresholds_Gasket Price Book - Access Hardware ...
Historical Fiction Titles - Tundra Books
Georgia Plumbing News: 2013 Industry Source Book
23448 V&N Technical Brochure UK Part 2 ART7_Layout 1