Views
5 years ago

Power Analysers & Recorders cont'd. - Ferret

Power Analysers & Recorders cont'd. - Ferret

ELECTRICAL POWER Current

ELECTRICAL POWER Current Clamp Probes & Accessories cont’d. Hioki 9661 CCT-500A Clamp-On Sensors 500A, 500mVAC Output HIO,9661 CCT-500A (8742) AU 500A rated, 500mVAC f.s. output, core jaw dia 46mmØ. Designed with a safety barrier to protect the user from being in direct contact with live conductors and completely meet all CE marking requirements. Basic specifications: Rated input current 500A AC, rated output current 0.5VAC, accuracy (at 45 to 66Hz), amplitude: ±0.5% rdg ±0.2% f.s. Full scale (f.s.) is the 3196 range value, phase: ±0.5° or less, frequency characteristics 66Hz to 5kHz (±1% or less from accuracy), max allowable input continuous 550A RMS (45 to 66Hz), max circuit voltage 600VAC RMS (insulated wire), core jaw Ø46mm, dimensions, mass 77mm W x 151mm H x 42mm D, 360g, cord length 3m. Hioki 9661-01 CCT-500A Clamp-on Sensors HIO,9661-01 CCT-500A (8742) AU 500A rated, 500mVAC fs output, jaw 46mmØ. Rated input current 500A AC, rated output current 0.5VAC, accuracy (at 45 to 66Hz). Amplitude ±0.5%rdg, ±0.2%f.s., fs is the 3196 range value, phase ±0.5° or less, frequency characteristics 66Hz to 5 kHz (±1%), max. Allowable input continuous 550A RMS (45 to 66Hz), max circuit voltage 600VAC RMS (insulated wire). Dimensions 77mm W x 151mm H x 42mm D, cord 3m. Suitable for Hioki models: 3196PQA, 3197PQA, 3169-20CLAMPONPT, 2331-20RPMS, 8715-01, any data logger/scope which takes up to 1.7mVAC input. HIO,9667-FCT-5000A (8792) AU 10Hz to 20kHz, 500/5,000A rated, 500mV AC f.s. output, 254mm diameter maximum. Designed with a safety barrier to protect the user from being in direct contact with live conductors and completely meet all CE marking requirements. Basic specifications: Rated input current 500A AC, 5,000A AC, rated output current 0.5V AC, accuracy (at 45 to 66Hz). Amplitude: ±2% rdg ±1.2mV, full scale (f.s.) is the 3196 range value, phase: ±1° or less, frequency characteristics 10Hz to 20kHz, maximum allowable input continuous 1,0000A rms (45 to 66Hz), maximum circuit voltage 1,000V AC rms (insulated wire), core jaw dia Ø254mm(10in). Dimensions: mass 254mmW x 86mmH x 30mmD, 140g. Sensor length: 910 mm. Suitable for the following Hioki Models: HIO,3196PQA, HIO,3197PQA, HIO,3169-20CLAMPONPT, HIO,2331-20RPMS, HIO,2331-20RPMS, HIO,8715-01, any data logger/scope which takes up to 1.7mV AC input. Hioki 9669-CCT-1000A Clamp-on Sensors HIO,9669-CCT-1000A (8744) AU Jaw 55mmØ, 80mm x 20mm busbar. Rated input current 1,000A AC, rated output current 0.5VAC, accuracy (at 45 to 66Hz) amplitude ±1% rdg, ±0.01% fs, fs is the 3196 range value, phase ±1° or less, frequency characteristics 66Hz to 5kHz (±1%), max. Allowable input continuous 1,000A RMS (45 to 66Hz), max circuit voltage 600VAC RMS (insulated wire). Dimensions 99.5mm W x 188mm H x 42mm D, cord 3m. Suitable for Hioki models 3196PQA, 3197PQA, 3169-20CLAMPONPT, 2331-20RPMS, 8715-01, any data logger/scope which takes up to 1.7mVAC input. 38 Current Clamp Probes & Accessories cont’d. www.techrentals.com.au Hioki 9670 Thermal Printer, Input RS232C, suitable for most of the Hioki Series HIO,9670 PRINTER (8759) AU Operates from a computer or the other host system. Battery operated. Prints 16 x 16 dots and 24 x 24 dots (as well as Japanese characters JIS Level I and II), and can print bar codes. Provides various settings such as enlarged-character printing. Graphics can be printed using bit images. Suitable for most of the Hioki Series. Hioki 9694 Clamp-on CT 5A HIO,9694CT5A (8741) AU Rated primary current 5A AC. Amplitude accuracy ±0.5% rdg. ±0.2% fs (at 45 to 66Hz), 66Hz to 5kHz ±1% or less. Max circuit voltage 300V RMS/insulated wire. Core jaw 15mmØ. Size mm: 46w × 21d × 135h, cord length 3m. LEM Current Probe 10A to 1A Suitable for LEM,TOPAS 1000 PQA LEM,CURRENT PROBE10A (8763) AU 10A to 1A suitable for LEM Topas 1000 power quality analyser. LEM FLEXII 30, 300 & 3,000A Transducer LEM,LEM-FLEXII (8638) AU Flexible wrap-around AC current transducer. Length 600mm. Ranges 30, 300A & 3kA. Frequency response 1 to 20kHz. Accuracy 1%. Phase error 0.5°. Output 3V RMS @ full scale. Requires 3 units for 3ph. Designed for multimeters and oscilloscopes (4mm banana plug or BNC connectors). Other instruments may be attached providing the correct adaptor/transducer and connection is available. Operates for 100h from 2 x 9V batteries. Universal Technic P75.3C DC/AC Amp Clamp UNI,P75-3C (8712) AU Max current 7,500A DC & AC peak. Bandwidth 1kHz. Min range 1kA. Accuracy at 75A 10% of reading. FS accuracy 2% of reading. Max bus size 122 x 54mm or 100 x 64mm. Max cable size 83mm. Battery 9V, life 100h. Output sockets 4mm. DC current gives DC output, AC current gives AC output, 4kA range 0.5mV per amp, 7.5kA range 0.2mV per A. Universal Technic Clamp-On AC/DC Current Probe 4000/7500A UNI,P75-3C HYBRID-DP (8713) AU Ranges 7,500A/1.5V & 4,000A/2V with hybrid power fitted for battery and external power supply, 3V operation. Safety sockets 4mm. Clamp is suitable for use with any instrument with an input range of 2VAC or DC, and an input impedance oscilloscopes, and power quality analysers. Insulation Testers & Meggers to 20kV Fluke 1587 Insulation Multimeter FLU,1587 MY 50V, 100V, 250V, 500V, 1,000V Multimeter: Voltage 1mV to 1,000VAC/DC, 1nF to 9999microF, frequency 0.01Hz to 99.99kHz. Fluke 1653 Electrical Installation Tester FLU,1653 MY Tester verify the safety of electrical installations, according to IEC 60364, HD 384 standards. Functions available: voltage and frequency measurement, insulation resistance testing, continuity testing, loop impedance, RCD tripping time, RCD tripping current, Earth resistance and Phase sequence.

www.techrentals.com.au Insulation Testers & Meggers to 20kV cont’d. HIO,3454-51-3 (8404) AU Continuity function with 200mA and 3 range voltage selectable 250V, 500V & 1kV. Digital display, auto-discharge, live-wire warning, safety system for high voltage measurement, sliding cover. Backlit LCD. Checks ground wire continuity with a short circuit current of 200mA. Ground continuity testing @ 1kV. Other functions:- insulation and low resistance mode - comparator, measurement value hold, insulation resistance mode - auto discharge, insulation and AC voltage mode. Maximum rated working voltage 600VAC. Hioki 3455 High Voltage Insulation Tester HIO,3455HVIT-5kV (8403) AU/MY PI and DAR function to check insulation quality and step voltage test to detect for signs of deterioration. Generates test voltages from 250V to 5kV in commonly used presets of 250V, 500V, 1kV, 2.5kV & 5kV, or set to desired level by increments or decrements of 25V or 100V. Insulation diagnoses for automatic calculation and indication of PI (Polarisation index) and DAR (Dielectric absorption ratio), step voltage testing and temperature correction. Large memory stores up to 100 manual records and a logging function for 10 data (360 times). Stored data with date and time may be displayed on the LCD or down-loaded. Megger 10-01 10kV Insulation Tester MEG,10-01-10kV (8424) AU Compact, Microprocessor controlled high voltage DC Insulation tester. Test voltage: 500V to 10kV. Megger BM21 500V/1/2/5kV Insulation Test Set MEG,BM21 MY measurement. Capacitance measurement at end of test. Automatic discharge of capacitance. In-built test timer. Insulation burn mode - short circuit current 1mA nominal. Battery life 8h, in-built charger for charging from mains or 12VDC. Megger FT6/12 Ionisation, Leakage & Breakdown Tester MEG,FT6/12 (8433) AU AC ranges 0 to 2kV, 0 to 6kV, DC ranges 0 to 4kV, 0 to 12kV. Output currents 7.4mA, 8.9mA AC & 2.1mA, 2.5mA DC. Breakdown and flashover indication by latching indicator for periods exceeding 1ms. Current threshold 100μA to 1mA. Ionisation indication by internal speaker. Meter indication of AC, DC and AC capacitive currents. Complete with probes. Megger MIT1020 Diagnostic 10kV Insulation Resistance Tester MEG,MIT1020-10kV DIT (8425) AU Backlit display, variable test voltage from 50 to 10,000V, Automatic IR, PI, DAR, SV and DD tests, results. IEEE 43-2000 recommends the use of 10kV for motor windings rated above 12kV. Protection rating of IP54. Mains or battery powered. Megger S1-1052 High Current Insulation Resistance Tester 10kV MEG,S1-1052 10kV-DIT (8413) AU High output current 5mA for fast charging of capacitive loads. Testing up to 10kV, mains or battery powered, digital/analogue backlit display, variable test voltage from 50 to 10,000V, automatic IR, PI, DAR, SV and DD 39 ELECTRICAL POWER Insulation Testers & Meggers to 20kV cont’d. Megger S1-552 High Current Insulation Resistance Tester 5kV MEG,S1-552 5kVDIT (8415) AU High output current 5mA for fast charging of capacitive loads. Testing up to 5kV, mains or battery powered, digital/analogue backlit display, variable test voltage from 50 to 5,000V, automatic IR, PI, DAR, SV and DD tests. Measures to Oil, Hipot & VFL Testers above 20kV See also Cable & Pipe Tracers & Fault Locators on page 29 Baur DAP75 Insulating Oil Tester BAU,DPA75 (4626) AU Fully automatic insulation oil tester. Output voltage 0 to 75kV RMS. Selectable programmes to international standards. Integral printer. RS232 interface. One transit case on wheels. Total weight is 35kgs. High Voltage Inc PFT303 Test Set 30kV/50Hz AC Hi Pot Tester HIV,PFT303 (8401) AU Rated 1kVA into resistive load, 3kVA into capacitive load. Duty cycle at 3kVA ½h on 2h off, at 2kVA 1h on 1h off. Tests the integrity of items including insulating materials, isophase bus duct, switchgear, transformers, vacuum bottles & interrupters, vacuum switches, automatic circuit reclosers, bushings, fuses, arrestors, circuit breakers, transformers, capacitors, motor and generator windings. High Voltage Inc PFT503, 50kV AC Test Set HIV,PFT503 (8400) AU Rated 1kVA into resistive load, 3kVA into capacitive load. Duty cycle at 3kVA ½h on 2h off, at 2kVA 1h on 1h off. High Voltage Inc Very Low Frequency (VLF) 6022 60kV Hi-pot Test Set HIV,VLF6022 (8461) AU For field testing of AC high/medium voltage cables, bushings, and insulators. Input 230V, 50Hz, 6A peak, 2.5A average. Output sinusoidal, 0 to 60kV AC peak, frequency 0.1, 0.05 & 0.02Hz. Duty continuous. Test load capacitance 1.1μF (approx 3kms of cable at 0.1Hz), 2.2μF (approx 9kms of cable at 0.05Hz) & 5.5μF (approx 13kms of cable at 0.02Hz). Display 0 to 60 peak kV. Interconnect cable length 3m, control unit to HV transformer. RG8/U output cable length 3m. Shorting stick braid 6m. HV tank and control units shipped in travel cases weighing 70 & 40kg respectively. High Voltage Inc VLF-90CM 90kV Test Set HIV,VLF90 (8462) AU Very low frequency (VLF-90CM) AC hipot test set with 90kVAC peak output, is suitable for testing cables up to 50kV. High load capacity enables it to test up to approx 7 miles of cable, depending on type. Includes a charging current and load capacitance meter, test dwell timer, and polarity indicating lights. Output voltage and frequency, sinusoidal 0 to 90kVAC peak & selectable, 0.1, 0.05, 0.02Hz. Test frequency and rated loads with approximate cable lengths are: -0.1Hz/0.55μF 1,673m of cable, 0.05Hz/1.1μF 3,353m of cable, 0.02Hz/2.2μF 6,706m of cable. Kilovoltmeter scaled 0 to 100kVAC peak, ammeter scaled 0 to 100mA AC and 0-6μF load capacitance. Weight of the unit 167kgs. HV Cable output is 6m flexible, shielded x-ray with alligator clamp, inter connect cable length 3m, shorting stick 6m lead with clip.

power quality analysing, recording and troubleshooting - Metrel dd
Power Generation Solutions - Ferret
MIG & MULTI-PROCESS MACHINES - Ferret
Power and productivity go hand in hand Mechanical power ... - Ferret
PM300 Power Analyser Brochure - Westek Electronics
WT210/WT230 Digital Power Meters - emitec-industrial.ch
RIPS - Recorder Independent Power Supply (ARINC Configuration)
WT300 SERIES DIGITAL POWER METER - Yokogawa
Precision Power Analyzer WT3000 - UPC
LMG95 Precision Power Meter LMG95
3350F Series High Power DC Electronic Load - Measuretronix Ltd.
Digital Fault Recorder - LogicLab srl
LMG450 4-Channel Power Analyzer LMG450 - Adler Instrumentos
300XAC Series Modular AC Power Sources - Texinstrumentos.com.br
DIGITAL LINEAR POWER SUPPLIES - Gigacomp
RIPS - Recorder Independent Power Supply (Tray Configuration)
Saving energy with Eco-power meters - Panasonic Electric Works ...
Flow Measurement & Control Solutions - Power Equipment Company
AC Power Sources AC Power Sources - Texinstrumentos.com.br
FR947EX/PMU - Digital Fault Recorder with PMU ... - LogicLab srl
Bulletin WT1800-00EN WT1800 High Performance Power Analyzer
Flow Measurement & Control - Bennes Power Line
Saving energy with Eco-power meters - Panasonic Electric Works ...
Ametek Programmable Power full 2009 Catalogue - RF Test Solutions