Client: <strong>Gabriel</strong><br />
Hjulmagervej 55<br />
Postbox 59<br />
DK-9100 Aalborg, Denmark<br />
Entry No: 50671-04<br />
Date Received: 3 rd May 2012<br />
Client’s Description: Sample <strong>of</strong> Fabric: Grace col 65066 Dark Purple<br />
TEST REPORT<br />
<strong>Th<strong>is</strong></strong> <strong>is</strong> <strong>hereby</strong> <strong>certified</strong> <strong>to</strong> <strong>be</strong> a <strong>correct</strong> <strong>return</strong> <strong>of</strong> <strong>the</strong> <strong>tests</strong> made <strong>of</strong> <strong>the</strong> items<br />
referred <strong>to</strong> herein.<br />
V Brockbank<br />
Senior Technician<br />
25 th July 2012<br />
Unless instructed o<strong>the</strong>rw<strong>is</strong>e by <strong>the</strong> client sample remnants will <strong>be</strong> d<strong>is</strong>posed <strong>of</strong> after 28 days<br />
Test marked (*) in th<strong>is</strong> certificate are not included in <strong>the</strong> UKAS Accreditation Schedule<br />
for th<strong>is</strong> Labora<strong>to</strong>ry.<br />
Opinions and interpretations expressed herein are outside <strong>the</strong> scope <strong>of</strong> UKAS accreditation.<br />
<strong>Th<strong>is</strong></strong> Certificate relates only <strong>to</strong> <strong>the</strong> sample received and, unless that sample has <strong>be</strong>en drawn<br />
by <strong>the</strong> staff <strong>of</strong> th<strong>is</strong> labora<strong>to</strong>ry, or its agent, and endorsed accordingly, any application <strong>of</strong> <strong>the</strong><br />
result <strong>to</strong> a bulk quantity or o<strong>the</strong>r material <strong>is</strong> entirely <strong>the</strong> responsibility <strong>of</strong> <strong>the</strong> client.<br />
PO Box 5, Morley, LS27 0QP Page 1 <strong>of</strong> 2<br />
Nepshaw Lane South, Morley, Leeds<br />
Tel 0113 253 0241 Fax 0113 252 7029<br />
Head <strong>of</strong> Labora<strong>to</strong>ry G. Briggs C. Text ATI<br />
Tests Required: Dimensional Stability <strong>to</strong> Washing, Seam Slippage, Colour Fastness <strong>to</strong> Rubbing<br />
with Organic Solvents<br />
Conditioning: In accordance with BS EN ISO 139 : 2005 for a minimum <strong>of</strong> 24 hours at 65 +/- 4%<br />
Relative Humidity, 20 +/- 2ºC where required<br />
Date <strong>of</strong> Tests: 17.5.12 <strong>to</strong> 24.5.12<br />
Dimensional Stability <strong>to</strong> Washing: BS EN ISO 5077 : 2008<br />
Procedure 3A at 60ºC specified in BS EN ISO 6330 : 2001 + A1 : 2009 Drying Procedure C : Flat Dry<br />
Warp:- -2.5%<br />
Weft:- -3.5%<br />
Procedure 6A at 40ºC specified in BS EN ISO 6330 : 2001 + A1 : 2009 Drying Procedure C : Flat Dry<br />
Warp:- -1.5%<br />
Weft:- -1.0%<br />
Note: minus indicates shrinkage<br />
----------------------------------------------------------------------------------------------------------------------------------------<br />
Seam Slippage: BS EN ISO 13936-2 : 2004<br />
Mean Seam Opening (mm)<br />
Warp Way Seam 3<br />
Weft Way Seam 3<br />
------------------------------------------------------------------End <strong>of</strong> Page---------------------------------------------------------
Client: <strong>Gabriel</strong><br />
Hjulmagervej 55<br />
Postbox 59<br />
DK-9100 Aalborg, Denmark<br />
Entry No. 50671-04<br />
Rubbing with Organic Solvents: BS EN ISO 105 – DO2 : 1996<br />
<strong>Th<strong>is</strong></strong> <strong>is</strong> <strong>hereby</strong> <strong>certified</strong> <strong>to</strong> <strong>be</strong> a <strong>correct</strong> <strong>return</strong> <strong>of</strong> <strong>the</strong> <strong>tests</strong> made <strong>of</strong> <strong>the</strong> items<br />
referred <strong>to</strong> herein.<br />
V Brockbank<br />
Senior Technician<br />
25 th July 2012<br />
Unless instructed o<strong>the</strong>rw<strong>is</strong>e by <strong>the</strong> client sample remnants will <strong>be</strong> d<strong>is</strong>posed <strong>of</strong> after 28 days<br />
Test marked (*) in th<strong>is</strong> certificate are not included in <strong>the</strong> UKAS Accreditation Schedule<br />
for th<strong>is</strong> Labora<strong>to</strong>ry.<br />
Opinions and interpretations expressed herein are outside <strong>the</strong> scope <strong>of</strong> UKAS accreditation.<br />
<strong>Th<strong>is</strong></strong> Certificate relates only <strong>to</strong> <strong>the</strong> sample received and, unless that sample has <strong>be</strong>en drawn<br />
by <strong>the</strong> staff <strong>of</strong> th<strong>is</strong> labora<strong>to</strong>ry, or its agent, and endorsed accordingly, any application <strong>of</strong> <strong>the</strong><br />
result <strong>to</strong> a bulk quantity or o<strong>the</strong>r material <strong>is</strong> entirely <strong>the</strong> responsibility <strong>of</strong> <strong>the</strong> client.<br />
PO Box 5, Morley, LS27 0QP Page 2 <strong>of</strong> 2<br />
Nepshaw Lane South, Morley, Leeds<br />
Tel 0113 253 0241 Fax 0113 252 7029<br />
Head <strong>of</strong> Labora<strong>to</strong>ry G. Briggs C. Text ATI<br />
Using Tetrachloroethylene Using White Spirit<br />
Staining:- Warp 4-5 4-5<br />
Weft 4-5 4-5<br />
Change in colour:- Warp 5 5<br />
Weft 5 5<br />
--------------------------------------------------------------End <strong>of</strong> Document--------------------------------------------------