<strong>Combo</strong> <strong>heating</strong> <strong>systems</strong>:<br />

<strong>domestic</strong> <strong>hot</strong> <strong>water</strong> <strong>and</strong> <strong>space</strong> combined<br />

This system uses a <strong>hot</strong> <strong>water</strong> tank to provide <strong>domestic</strong><br />

<strong>hot</strong> <strong>water</strong> <strong>and</strong> is also a source of heat for a hydronic (<strong>hot</strong><br />

<strong>water</strong>) <strong>space</strong> <strong>heating</strong> system. The common terminology<br />

for this type of dual function system is a combo system.<br />

The primary function of the <strong>hot</strong> <strong>water</strong> tank is to heat<br />

<strong>water</strong> that flows from the tank to a <strong>space</strong> <strong>heating</strong><br />

system. In addition, this tank can also supply <strong>water</strong><br />

used for <strong>domestic</strong> service (showers, dishwasher, etc.).<br />

The <strong>space</strong> <strong>heating</strong> system can consist of a radiant<br />

floor, hydronic baseboard radiators, fan coil units, or<br />

combinations of all three <strong>systems</strong>. Heating can be zoned<br />

for individual room or area thermostatic control.<br />

The schematic diagram shows a system with a fan coil<br />

connected to the <strong>hot</strong> <strong>water</strong> tank. No heat exchanger is<br />

required for this scenario; however, the system does<br />

require a pump with a cycle timer, <strong>and</strong> the equipment<br />

must be certified for use with potable <strong>water</strong>.<br />

Additional diagrams in this set show piping <strong>and</strong> layout<br />

for in-slab radiant floor <strong>heating</strong> <strong>systems</strong>. Radiant<br />

floor <strong>systems</strong> require a heat exchanger, <strong>and</strong> have two<br />

completely separate <strong>water</strong> <strong>systems</strong>.<br />

When there is a dem<strong>and</strong> for <strong>domestic</strong> <strong>hot</strong> <strong>water</strong> for<br />

showers, dishwashing etc., the <strong>water</strong> heater provides <strong>hot</strong><br />

<strong>water</strong> directly from the tank.<br />

<strong>Combo</strong> system manufacturers claim that system<br />

efficiencies can be increased somewhat when compared<br />

to regular <strong>domestic</strong> <strong>water</strong> heaters. This is because it is<br />

assumed that <strong>domestic</strong> <strong>hot</strong> <strong>water</strong> is not required for<br />

about 20 to 22 hours per day, <strong>and</strong> heat may be wasted to<br />

maintain <strong>water</strong> temperature while the tank is idle. In<br />

a combo system, the tank functions 24 hours a day as a<br />

source of heat for <strong>space</strong> <strong>heating</strong>.<br />

Special design considerations <strong>and</strong> sizing guidelines<br />

must be followed when considering a combo system.<br />

These guidelines are outlined in documents published<br />

by the Thermal Environmental Comfort Association<br />

(TECA) <strong>and</strong> other associations.<br />

NOTE: Municipal regulations should also be checked.<br />

Discover how to incorporate natural gas into your<br />

next project at fortisbc.com/energyteam.<br />

Energy solutions. We’ve got our best people on it.<br />

CEILING<br />

CW<br />

SUPPLY<br />

TO SUITE<br />

FLOOR<br />

DHW<br />

HEADER<br />

TYPICAL DHW<br />

TAKE OFF TO<br />

FIXTURE(S)<br />

EXPANSION<br />

TANK<br />

TYPICAL DCW<br />

TAKE OFF TO<br />

FIXTURE(S)<br />

DCW HEADER<br />

SUITE PRESSURE REDUCING VALVE<br />

SUITE SHUT OFF VALVE<br />

POWER VENT<br />

FLUE TO<br />

OUTSIDE<br />

WALL CAP<br />

GAS PIPE FROM<br />

METER CLOSETS<br />

& ASSOC. METER<br />

THERMOMETER<br />

G<br />

G<br />

FAN COIL C/W PUMP<br />

AND CYCLE TIMER,<br />

CERTIFIED FOR<br />

POTABLE WATER<br />

UNION (TYP.)<br />

DUAL FUNCTION HOT<br />

WATER TANK<br />

COMBO SYSTEM FAN COIL — SCHEMATIC<br />

Scale: NTS<br />

DISCLAIMER: This drawing is diagrammatic only. Not to be used for construction purposes.


COMBO SYSTEM — FAN COIL—<br />

FLOOR PLAN<br />

COMBUSTION<br />

AIR INTAKE<br />

GAS PIPE FROM<br />

GAS METER CLOSET<br />

G<br />

G<br />

Energy solutions. We’ve got our best people on it.<br />

HWT VENT GRILLE AT<br />

BALCONY CEILING<br />

EXHAUST VENT<br />

THERMOSTAT<br />

DUAL FUNCTION<br />

HOT WATER TANK<br />

Scale: NTS<br />

DISCLAIMER: This drawing is diagrammatic only. Not to be used for<br />

construction purposes.<br />

TYPICAL SUPPLY<br />

AIR DUCT<br />

T<br />

HORIZONTAL<br />

FAN COIL<br />

(IN CEILING SPACE)<br />

RETURN AIR GRILLE<br />

<strong>FortisBC</strong> Energy Inc., <strong>FortisBC</strong> Energy (Vancouver Isl<strong>and</strong>) Inc. <strong>and</strong> <strong>FortisBC</strong> Energy (Whistler) Inc. do business as <strong>FortisBC</strong>. The companies are indirect, wholly owned subsidiaries of Fortis Inc.<br />

<strong>FortisBC</strong> uses the <strong>FortisBC</strong> name <strong>and</strong> logo under license from Fortis Inc.<br />

(11-552.17s 12/2011)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!