ProduCtinformation<br />

PD-2<br />

<strong>Level</strong> <strong>data</strong> <strong>logger</strong><br />

<strong>Functions</strong> <strong>and</strong> <strong>advantages</strong><br />

<strong>»</strong><br />

<strong>»</strong><br />

<strong>»</strong><br />

<strong>»</strong><br />

<strong>»</strong><br />

<strong>»</strong><br />

<strong>»</strong><br />

<strong>»</strong><br />

measurement of water level <strong>and</strong> temperature<br />

in level pipes, wells, containers, open water or<br />

discharge measurement with weir<br />

interval-oriented or event-oriented <strong>data</strong> storage of<br />

actual value, minimum, maximum <strong>and</strong> average value<br />

<strong>data</strong> retrieval on site or via remote <strong>data</strong> transfer<br />

10 years’ operation with lithium battery - battery<br />

exchange by user possible<br />

Water-resistant with protection type iP68<br />

minimum energy requirement due to “sleep mode”<br />

GSm - option: mechanically compact GSm unit<br />

incl. energy supply with battery or solar panel<br />

Plus - option: conditional storage, report issue<br />

when limit value exceeded <strong>and</strong> SmS dispatch of<br />

current values


ProduCtinformation Pd- p / Pd- p plus<br />

Introducing the PD- p product range<br />

the level <strong>data</strong> <strong>logger</strong> was developed for extremly<br />

rough use in harsh environments. it is<br />

therefore suitable for reliable acquisition <strong>and</strong><br />

storage of water level <strong>and</strong> temperature in level<br />

pipes <strong>and</strong> boreholes. the Pd- is also a durable<br />

device for <strong>data</strong> acquisition in water tanks<br />

or surface waters.<br />

the sensor cable with an integrated pressure<br />

compensation capillary prevents measuring<br />

Basic PD- p version<br />

errors by compensating fluctuations in barometric<br />

air pressure. its low power consumption<br />

<strong>and</strong> large <strong>data</strong> memory enable effortless recording<br />

of water levels <strong>and</strong> temperatures over<br />

extended periods of time. Captured measured<br />

values can be recorded at time-synchronised<br />

intervals.<br />

recording <strong>and</strong> storage of levels <strong>and</strong> temperatures in adjustable storage intervals of between 1s <strong>and</strong><br />

4h. the <strong>data</strong> is shown graphically <strong>and</strong> in table form using ComWin software via a PC or laptop. the<br />

<strong>data</strong> can also be retrieved via remote <strong>data</strong> transfer using GSm/GPrS.<br />

“GSM” option<br />

mechanically compact extension for power-saving operation of measuring sites with remote <strong>data</strong> transfer.<br />

the pack contains a GSm/GPrS modem, a planar antenna with anti-v<strong>and</strong>alism protection in the level<br />

cap <strong>and</strong> an energy supply. the energy is supplied either via a battery/rechargeable battery or via a solar<br />

panel as required.<br />

“plus” option<br />

<strong>data</strong> storage an improved <strong>data</strong> density is desirable with natural<br />

events more than any other. the Pd- p level<br />

<strong>data</strong> <strong>logger</strong> offers different ways of storing <strong>data</strong>:<br />

•<br />

•<br />

•<br />

interval-oriented storage (scheduled storage)<br />

Conditional storage with a limit value or limit<br />

value range (relative or absolute)<br />

Event-controlled storage<br />

Comprehensive reporting function active report issuing when the limit value is<br />

exceeded via a telephone call or SmS<br />

•<br />

•<br />

report issued when limit values are not<br />

reached or are exceeded (relative or absolute)<br />

report issued when a relative value change<br />

occurs in a certain time period<br />

retrieval of the measurement values via SmS When a GSm/GPrS modem is connected, current<br />

actual values can be retrieved at any time


ProduCtinformation Pd- p / Pd- p plus<br />

Data storage<br />

When extreme events occur, high time resolutions<br />

of the <strong>data</strong> sequences are required for evaluation<br />

<strong>and</strong> analysis purposes. outside of the extreme<br />

event, only a low <strong>data</strong> quantity is required. the<br />

st<strong>and</strong>ard Pd- p design is only capable of intervaloriented<br />

storage. With the Pd- pplus, anything<br />

interval-oriented storage<br />

for each connected measuring input, the measuring<br />

<strong>data</strong> can be recorded in an interval of between<br />

1s <strong>and</strong> 4h (fig. 1).<br />

Types of measurement<br />

frequently, it is not only the recording of the<br />

current measurement value which is necessary<br />

in order to assess an environmental event,<br />

but also a statistical recording of the measure-<br />

Minimum energy requirement due to “sleep mode”<br />

in order to construct measurement systems which<br />

can operate at a distance from any infrastructure,<br />

components are needed with energy management<br />

in order to keep energy requirements at a<br />

low level. the Pd- p range requires low levels<br />

of energy due to a special sleep mode between<br />

the recording intervals. Communication (e.g. <strong>data</strong><br />

retrieval with a GSm modem) requires the largest<br />

amount of energy. Due to configurable time<br />

management for the modem, the energy requirement<br />

is significantly reduced. Taking into account<br />

the rate time of the sensor (which guarantees<br />

is possible, from simple interval storage through<br />

to event-related conditional storage when natural<br />

events occur. the conditional storage possible<br />

with the Pd- pplus is particularly useful with<br />

pump <strong>and</strong> surge tests.<br />

Fig. 1: Synchronous storage of a measurement value<br />

ment values for evaluation purposes. With this<br />

in mind, the Pd- p range offers actual value,<br />

maximum, minimum, average value.<br />

a stable measurement result), each individual<br />

sensor (level or temperature) is only switched on<br />

for the measurement, <strong>and</strong> thus plays an important<br />

role in saving energy. due to these energy<br />

saving measures, long-term operation with an<br />

autonomous energy source can be guaranteed<br />

with a solar panel <strong>and</strong> rechargeable battery for a<br />

st<strong>and</strong>ard measuring station. Even under difficult<br />

environmental conditions such as high alpine stations,<br />

continuous operation is secured despite the<br />

solar panel icing up or low levels of solar power<br />

due to a shady location during the winter.


ProduCtinformation Pd- p / Pd- p plus<br />

Option „GSM“<br />

the battery or solar GSm units are the ideal addition<br />

for the Pd- level <strong>data</strong> <strong>logger</strong>. this is an easy way to<br />

exp<strong>and</strong> the functionality of the Pd- by remote <strong>data</strong><br />

transmission, making time-consuming journeys to<br />

GSM unit battery GSM unit solar<br />

the battery GSm unit is strikingly compact. designed<br />

for use in level pipes, it can be integrated<br />

into pipes of 4 inches or more in diameter without<br />

additional mechanical construction. an opening in<br />

the housing also allows control measurements to<br />

be made with the electric contact meter, without<br />

dismantling the measuring system.<br />

Fig. 2: With Batterie <strong>and</strong> GSM-Modem<br />

mounted in observation well .<br />

the measuring point to read out the <strong>data</strong> a thing of<br />

the past. Long operating periods are possible, as the<br />

Pd- actuates the GSm modem individually.<br />

the solar GSm unit is designed for installation on<br />

level pipes or poles. Completely autonomous solar-powered<br />

measuring points can be implemented<br />

quickly <strong>and</strong> easily, even at sources or rivers,<br />

for example.<br />

Fig. 3: With solar panel <strong>and</strong> GSM-Modem<br />

mounted at observation well .


ProduCtinformation Pd- p / Pd- p plus<br />

“plus” option: remote <strong>data</strong> transfer, conditional storage <strong>and</strong> reporting<br />

due to the extended functionality provided by the<br />

optional “plus” pack, the basic version of the Pd- p<br />

is converted into an intelligent level <strong>data</strong> <strong>logger</strong> with<br />

conditional storage when limit values or limit value<br />

ranges are exceeded or not reached, in order to store<br />

the measurement values at shortened intervals when<br />

retrieval of the measurement values via SmS<br />

if a GSm modem is connected to the <strong>data</strong> <strong>logger</strong>, the<br />

current measurement values of the sensors can be<br />

retrieved at any time with the aid of SmS dispatch,<br />

Conditional storage<br />

in addition to the functions of the interval-oriented<br />

storage, conditions such as a limit value or limit<br />

value range can be defined, which trigger a sto-<br />

Test type Explanation<br />

absolute limit value excess<br />

relative limit value excess<br />

time-related limit value excess<br />

Conditional storage with limit value<br />

The storage is triggered as a result of definitions of<br />

limit values which are either not reached or are exceeded.<br />

at the same time as the synchronous storage,<br />

Fig. 4: Absolute limit value excess: additional 1minute<br />

asynchronous storage when limit value<br />

is exceeded – event is recorded at high resolution<br />

Fig. 5: Relative limit value excess: storage is<br />

triggered when a relative measure value is<br />

changed<br />

natural events occur. furthermore, the optional pack<br />

also st<strong>and</strong>s out with its comprehensive reporting function<br />

in order to issue warnings via SmS or a telephone<br />

call. the possibility of retrieving current actual <strong>data</strong><br />

via SmS is of practical help in order to quickly assess<br />

the situation on site at any time.<br />

<strong>and</strong> shown on any mobile telephone. the <strong>data</strong> <strong>logger</strong><br />

responds to a request SmS with a response SmS<br />

showing the current measurement values.<br />

rage. in order to realise complex measuring requirements,<br />

the following types of test can be set<br />

for the conditional storage.<br />

the measurement value is directly checked to determine<br />

wither a limit value/limit range has not been<br />

reached/has been exceeded (fig. 4)<br />

an check of the relative change in measurement<br />

value. measurement value change not related to<br />

time (fig. 5)<br />

a check of the relative change in measurement<br />

value within a defined time period (Fig. 6),<br />

e.g. speeds of changes, etc.<br />

e.g. at 10-minute intervals, a conditional, asynchronous<br />

storage can be conducted when the limit value is<br />

exceeded, e.g. in 1-minute intervals.<br />

Fig. 6: Time-related limit value excess: storage<br />

in 1-minute intervals when the measurement<br />

value changes by the value 30 in 3 minutes<br />

– events are recorded at high resolution


ProduCtinformation Pd- p / Pd- p plus<br />

Fig. 7: Limit value range: when the limits are<br />

not reached or are exceeded, additional asynchronous<br />

storage is conducted in a 5-minute<br />

interval resolution<br />

Comprehensive reporting function<br />

Event-controlled storage<br />

Depending on the definition of the limit value <strong>and</strong><br />

the type of test, different reporting scenarios can<br />

be realised. the report is issued when a limit value<br />

is exceeded/is not reached, or when an event occurs,<br />

<strong>and</strong> the report is triggered by a combination<br />

with another measurement value/limit value. the<br />

report is issued by means of a relay contact for<br />

Type of test Explanation<br />

Conditional storage with limit<br />

value range<br />

if a limit value range is defined,<br />

the <strong>data</strong> is stored when the<br />

measurement value lies within or<br />

outside the range (fig. 7).<br />

the <strong>data</strong> storage of a measurement<br />

value is conducted depending<br />

on the entrance of one or<br />

more events for other measurement<br />

values, i.e. a combined switching<br />

of measurement <strong>data</strong> (e.g.<br />

limit value excess – fig. 8).<br />

Fig. 8: Event-controlled storage: when a limit<br />

value is exceeded of measurement value A<br />

(MV A), the storage for measurement value B<br />

(MV B) is conducted in 1-minute intervals<br />

switching connected systems, by a modem call in<br />

order to forward the report in warning systems, or<br />

by SmS in order to inform individuals. the limit value<br />

is always defined in combination with a hysteresis<br />

value in order to prevent multiple messages<br />

due to the fluctuating measurement values.<br />

absolute value the measurement value is checked directly as to whether a limit<br />

value/limit range has been exceeded (fig. 9)<br />

relative change the report is triggered when a relative measurement change is exceeded<br />

or not reached, not related to time (fig. 10)<br />

time-related change the report is triggered when a relative change to the measurement<br />

value is exceeded or not reached within a defined time period<br />

(fig. 11), e.g. change speeds, etc.<br />

Fig. 9: Triggering when pre-defined limit<br />

values are absolutely exceeded<br />

Fig. 10: Triggering when a relative value<br />

change is exceeded<br />

Fig. 11: Triggering when within a time period,<br />

the measurement value exceeds a relative<br />

value change


ProduCtinformation Pd- p / Pd- p plus<br />

Parameterising <strong>and</strong> reading <strong>data</strong><br />

The level <strong>data</strong> <strong>logger</strong> is configured <strong>and</strong> the stored<br />

measurement values are read conveniently using<br />

a PC or laptop with ComWin software.<br />

the level <strong>data</strong> <strong>logger</strong> is connected to the computer<br />

via the serial interface <strong>and</strong> a special connection<br />

cable. after the level <strong>data</strong> <strong>logger</strong> type has<br />

been selected, the parameterisation window<br />

appears. all settings can be seen clearly in just<br />

one single window (see fig. 1 ).<br />

for reading the <strong>data</strong>, the convenient option is<br />

available of reading with a single mouse click all<br />

new measurement <strong>data</strong> which has arrived since<br />

the last reading, <strong>and</strong> immediately showing it in<br />

graphic/table form, or reading a specific time period<br />

(see fig. 13). for a quick view of the <strong>data</strong>,<br />

only the current actual values can be shown, in<br />

order to conduct an actual value compensation,<br />

for example.<br />

Fig. 14: Comparative graphic e.g. of different levels<br />

Fig. 15: Representation of the <strong>data</strong> sequences in table form<br />

Fig. 12: Parameterisation – overview window<br />

Fig. 13: Read <strong>data</strong> from a specific time period<br />

the read <strong>data</strong> can be shown <strong>and</strong> stored in graphic or<br />

table form. for comparative representations, several<br />

curves from different level <strong>data</strong> <strong>logger</strong>s can be<br />

combined in a single graphic or table (see figs. 14<br />

<strong>and</strong> 15).<br />

the graphic representation st<strong>and</strong>s out for its simple<br />

operation <strong>and</strong> automatic axis scaling of the graphic.<br />

for professional users, a wide range of setting<br />

options are available, such as axle scaling or zoom<br />

functions.<br />

the representation in table form gives all the <strong>data</strong><br />

in the graphic shown (see fig. 15). Rapid toggling<br />

between graphic <strong>and</strong> table representations is possible<br />

with a single mouse click.<br />

With the export function, the <strong>data</strong> is stored via a<br />

converter in Excel format, or in any format specified<br />

by the customer.<br />

We offer the DataWin <strong>and</strong> MetWin solution for more<br />

comprehensive <strong>data</strong> analyses <strong>and</strong> the fully automated<br />

retrieval of all measuring systems through to<br />

measuring networks.


ProduCtinformation Pd- p / Pd- p plus<br />

Technical specifications<br />

Pd- p<br />

measuring range – level<br />

measuring range – temperature<br />

functions<br />

Storage methods<br />

memory<br />

Scope of delivery<br />

<strong>»</strong> <strong>Level</strong> <strong>data</strong> <strong>logger</strong>; cable length must be given when ordering.<br />

SOMMEr GmbH & Co KG<br />

Straßenhäuser 7<br />

a-684 Koblach<br />

tel.: +43 55 3 55989 – 0<br />

fax: +43 55 3 55989 – 19<br />

Email: office@sommer.at<br />

internet: www.sommer.at<br />

measuring range: 5, 10, 15, 0m with 1mm resolution<br />

Precision: 0.1% (fS); measuring principle / sensor: piezoresitiv<br />

measuring range: -10°C to +50°C at 0.1°C resolution<br />

Precision: 0.1% (fS); measuring principle / sensor: Pt 1000<br />

<strong>Level</strong> <strong>and</strong> water temperature<br />

Scheduled values, average values, minimum, maximum<br />

Synchronous storage: interval of seconds to 4 hours<br />

(time-synchronous)<br />

mB memory size<br />

(corresponds to approx. 600,000 measurement values)<br />

interface – digital Serial; rS 3 with 1. – 115 kBd transmission speed<br />

remote <strong>data</strong> transfer<br />

Supply<br />

Current-saving operation of the measuring site with remote<br />

<strong>data</strong> transfer due to integrated modem triggering<br />

Lithium battery: 3.6 VdC / 6 ah (can be replaced by the user)<br />

Battery life: up to 10 years (with 15-minute measuring interval)<br />

areas of application/protection type operating temperature: -10°C to +50°C; overload: 3 bar; iP 68<br />

assembly Suspension device for simply assembly in level pipes<br />

Pd- p plus (additional functions to the Pd- p)<br />

Storage methods Conditional <strong>and</strong> event-controlled storage<br />

Warning<br />

active report issuing/warning via telephone call or SmS after<br />

defined limits are exceeded<br />

measurement value retrieval via SmS retrieval regardless of location of the current actual values via SmS<br />

See the <strong>data</strong>sheet for all technical specifications<br />

Copyright<br />

© Copyright 007 Sommer. all rights reserved. Content may be changed<br />

without notice. Pictures, drawings <strong>and</strong> other graphic images are for illustration<br />

only <strong>and</strong> do not represent product configuration.<br />

Exclusion<br />

Subject to deliverability, technical changes <strong>and</strong> errors excepted.