Functions and advantages » » » » » » » » Level data logger
Functions and advantages » » » » » » » » Level data logger
Functions and advantages » » » » » » » » Level data logger
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
ProduCtinformation<br />
PD-2<br />
<strong>Level</strong> <strong>data</strong> <strong>logger</strong><br />
<strong>Functions</strong> <strong>and</strong> <strong>advantages</strong><br />
<strong>»</strong><br />
<strong>»</strong><br />
<strong>»</strong><br />
<strong>»</strong><br />
<strong>»</strong><br />
<strong>»</strong><br />
<strong>»</strong><br />
<strong>»</strong><br />
measurement of water level <strong>and</strong> temperature<br />
in level pipes, wells, containers, open water or<br />
discharge measurement with weir<br />
interval-oriented or event-oriented <strong>data</strong> storage of<br />
actual value, minimum, maximum <strong>and</strong> average value<br />
<strong>data</strong> retrieval on site or via remote <strong>data</strong> transfer<br />
10 years’ operation with lithium battery - battery<br />
exchange by user possible<br />
Water-resistant with protection type iP68<br />
minimum energy requirement due to “sleep mode”<br />
GSm - option: mechanically compact GSm unit<br />
incl. energy supply with battery or solar panel<br />
Plus - option: conditional storage, report issue<br />
when limit value exceeded <strong>and</strong> SmS dispatch of<br />
current values
ProduCtinformation Pd- p / Pd- p plus<br />
Introducing the PD- p product range<br />
the level <strong>data</strong> <strong>logger</strong> was developed for extremly<br />
rough use in harsh environments. it is<br />
therefore suitable for reliable acquisition <strong>and</strong><br />
storage of water level <strong>and</strong> temperature in level<br />
pipes <strong>and</strong> boreholes. the Pd- is also a durable<br />
device for <strong>data</strong> acquisition in water tanks<br />
or surface waters.<br />
the sensor cable with an integrated pressure<br />
compensation capillary prevents measuring<br />
Basic PD- p version<br />
errors by compensating fluctuations in barometric<br />
air pressure. its low power consumption<br />
<strong>and</strong> large <strong>data</strong> memory enable effortless recording<br />
of water levels <strong>and</strong> temperatures over<br />
extended periods of time. Captured measured<br />
values can be recorded at time-synchronised<br />
intervals.<br />
recording <strong>and</strong> storage of levels <strong>and</strong> temperatures in adjustable storage intervals of between 1s <strong>and</strong><br />
4h. the <strong>data</strong> is shown graphically <strong>and</strong> in table form using ComWin software via a PC or laptop. the<br />
<strong>data</strong> can also be retrieved via remote <strong>data</strong> transfer using GSm/GPrS.<br />
“GSM” option<br />
mechanically compact extension for power-saving operation of measuring sites with remote <strong>data</strong> transfer.<br />
the pack contains a GSm/GPrS modem, a planar antenna with anti-v<strong>and</strong>alism protection in the level<br />
cap <strong>and</strong> an energy supply. the energy is supplied either via a battery/rechargeable battery or via a solar<br />
panel as required.<br />
“plus” option<br />
<strong>data</strong> storage an improved <strong>data</strong> density is desirable with natural<br />
events more than any other. the Pd- p level<br />
<strong>data</strong> <strong>logger</strong> offers different ways of storing <strong>data</strong>:<br />
•<br />
•<br />
•<br />
interval-oriented storage (scheduled storage)<br />
Conditional storage with a limit value or limit<br />
value range (relative or absolute)<br />
Event-controlled storage<br />
Comprehensive reporting function active report issuing when the limit value is<br />
exceeded via a telephone call or SmS<br />
•<br />
•<br />
report issued when limit values are not<br />
reached or are exceeded (relative or absolute)<br />
report issued when a relative value change<br />
occurs in a certain time period<br />
retrieval of the measurement values via SmS When a GSm/GPrS modem is connected, current<br />
actual values can be retrieved at any time
ProduCtinformation Pd- p / Pd- p plus<br />
Data storage<br />
When extreme events occur, high time resolutions<br />
of the <strong>data</strong> sequences are required for evaluation<br />
<strong>and</strong> analysis purposes. outside of the extreme<br />
event, only a low <strong>data</strong> quantity is required. the<br />
st<strong>and</strong>ard Pd- p design is only capable of intervaloriented<br />
storage. With the Pd- pplus, anything<br />
interval-oriented storage<br />
for each connected measuring input, the measuring<br />
<strong>data</strong> can be recorded in an interval of between<br />
1s <strong>and</strong> 4h (fig. 1).<br />
Types of measurement<br />
frequently, it is not only the recording of the<br />
current measurement value which is necessary<br />
in order to assess an environmental event,<br />
but also a statistical recording of the measure-<br />
Minimum energy requirement due to “sleep mode”<br />
in order to construct measurement systems which<br />
can operate at a distance from any infrastructure,<br />
components are needed with energy management<br />
in order to keep energy requirements at a<br />
low level. the Pd- p range requires low levels<br />
of energy due to a special sleep mode between<br />
the recording intervals. Communication (e.g. <strong>data</strong><br />
retrieval with a GSm modem) requires the largest<br />
amount of energy. Due to configurable time<br />
management for the modem, the energy requirement<br />
is significantly reduced. Taking into account<br />
the rate time of the sensor (which guarantees<br />
is possible, from simple interval storage through<br />
to event-related conditional storage when natural<br />
events occur. the conditional storage possible<br />
with the Pd- pplus is particularly useful with<br />
pump <strong>and</strong> surge tests.<br />
Fig. 1: Synchronous storage of a measurement value<br />
ment values for evaluation purposes. With this<br />
in mind, the Pd- p range offers actual value,<br />
maximum, minimum, average value.<br />
a stable measurement result), each individual<br />
sensor (level or temperature) is only switched on<br />
for the measurement, <strong>and</strong> thus plays an important<br />
role in saving energy. due to these energy<br />
saving measures, long-term operation with an<br />
autonomous energy source can be guaranteed<br />
with a solar panel <strong>and</strong> rechargeable battery for a<br />
st<strong>and</strong>ard measuring station. Even under difficult<br />
environmental conditions such as high alpine stations,<br />
continuous operation is secured despite the<br />
solar panel icing up or low levels of solar power<br />
due to a shady location during the winter.
ProduCtinformation Pd- p / Pd- p plus<br />
Option „GSM“<br />
the battery or solar GSm units are the ideal addition<br />
for the Pd- level <strong>data</strong> <strong>logger</strong>. this is an easy way to<br />
exp<strong>and</strong> the functionality of the Pd- by remote <strong>data</strong><br />
transmission, making time-consuming journeys to<br />
GSM unit battery GSM unit solar<br />
the battery GSm unit is strikingly compact. designed<br />
for use in level pipes, it can be integrated<br />
into pipes of 4 inches or more in diameter without<br />
additional mechanical construction. an opening in<br />
the housing also allows control measurements to<br />
be made with the electric contact meter, without<br />
dismantling the measuring system.<br />
Fig. 2: With Batterie <strong>and</strong> GSM-Modem<br />
mounted in observation well .<br />
the measuring point to read out the <strong>data</strong> a thing of<br />
the past. Long operating periods are possible, as the<br />
Pd- actuates the GSm modem individually.<br />
the solar GSm unit is designed for installation on<br />
level pipes or poles. Completely autonomous solar-powered<br />
measuring points can be implemented<br />
quickly <strong>and</strong> easily, even at sources or rivers,<br />
for example.<br />
Fig. 3: With solar panel <strong>and</strong> GSM-Modem<br />
mounted at observation well .
ProduCtinformation Pd- p / Pd- p plus<br />
“plus” option: remote <strong>data</strong> transfer, conditional storage <strong>and</strong> reporting<br />
due to the extended functionality provided by the<br />
optional “plus” pack, the basic version of the Pd- p<br />
is converted into an intelligent level <strong>data</strong> <strong>logger</strong> with<br />
conditional storage when limit values or limit value<br />
ranges are exceeded or not reached, in order to store<br />
the measurement values at shortened intervals when<br />
retrieval of the measurement values via SmS<br />
if a GSm modem is connected to the <strong>data</strong> <strong>logger</strong>, the<br />
current measurement values of the sensors can be<br />
retrieved at any time with the aid of SmS dispatch,<br />
Conditional storage<br />
in addition to the functions of the interval-oriented<br />
storage, conditions such as a limit value or limit<br />
value range can be defined, which trigger a sto-<br />
Test type Explanation<br />
absolute limit value excess<br />
relative limit value excess<br />
time-related limit value excess<br />
Conditional storage with limit value<br />
The storage is triggered as a result of definitions of<br />
limit values which are either not reached or are exceeded.<br />
at the same time as the synchronous storage,<br />
Fig. 4: Absolute limit value excess: additional 1minute<br />
asynchronous storage when limit value<br />
is exceeded – event is recorded at high resolution<br />
Fig. 5: Relative limit value excess: storage is<br />
triggered when a relative measure value is<br />
changed<br />
natural events occur. furthermore, the optional pack<br />
also st<strong>and</strong>s out with its comprehensive reporting function<br />
in order to issue warnings via SmS or a telephone<br />
call. the possibility of retrieving current actual <strong>data</strong><br />
via SmS is of practical help in order to quickly assess<br />
the situation on site at any time.<br />
<strong>and</strong> shown on any mobile telephone. the <strong>data</strong> <strong>logger</strong><br />
responds to a request SmS with a response SmS<br />
showing the current measurement values.<br />
rage. in order to realise complex measuring requirements,<br />
the following types of test can be set<br />
for the conditional storage.<br />
the measurement value is directly checked to determine<br />
wither a limit value/limit range has not been<br />
reached/has been exceeded (fig. 4)<br />
an check of the relative change in measurement<br />
value. measurement value change not related to<br />
time (fig. 5)<br />
a check of the relative change in measurement<br />
value within a defined time period (Fig. 6),<br />
e.g. speeds of changes, etc.<br />
e.g. at 10-minute intervals, a conditional, asynchronous<br />
storage can be conducted when the limit value is<br />
exceeded, e.g. in 1-minute intervals.<br />
Fig. 6: Time-related limit value excess: storage<br />
in 1-minute intervals when the measurement<br />
value changes by the value 30 in 3 minutes<br />
– events are recorded at high resolution
ProduCtinformation Pd- p / Pd- p plus<br />
Fig. 7: Limit value range: when the limits are<br />
not reached or are exceeded, additional asynchronous<br />
storage is conducted in a 5-minute<br />
interval resolution<br />
Comprehensive reporting function<br />
Event-controlled storage<br />
Depending on the definition of the limit value <strong>and</strong><br />
the type of test, different reporting scenarios can<br />
be realised. the report is issued when a limit value<br />
is exceeded/is not reached, or when an event occurs,<br />
<strong>and</strong> the report is triggered by a combination<br />
with another measurement value/limit value. the<br />
report is issued by means of a relay contact for<br />
Type of test Explanation<br />
Conditional storage with limit<br />
value range<br />
if a limit value range is defined,<br />
the <strong>data</strong> is stored when the<br />
measurement value lies within or<br />
outside the range (fig. 7).<br />
the <strong>data</strong> storage of a measurement<br />
value is conducted depending<br />
on the entrance of one or<br />
more events for other measurement<br />
values, i.e. a combined switching<br />
of measurement <strong>data</strong> (e.g.<br />
limit value excess – fig. 8).<br />
Fig. 8: Event-controlled storage: when a limit<br />
value is exceeded of measurement value A<br />
(MV A), the storage for measurement value B<br />
(MV B) is conducted in 1-minute intervals<br />
switching connected systems, by a modem call in<br />
order to forward the report in warning systems, or<br />
by SmS in order to inform individuals. the limit value<br />
is always defined in combination with a hysteresis<br />
value in order to prevent multiple messages<br />
due to the fluctuating measurement values.<br />
absolute value the measurement value is checked directly as to whether a limit<br />
value/limit range has been exceeded (fig. 9)<br />
relative change the report is triggered when a relative measurement change is exceeded<br />
or not reached, not related to time (fig. 10)<br />
time-related change the report is triggered when a relative change to the measurement<br />
value is exceeded or not reached within a defined time period<br />
(fig. 11), e.g. change speeds, etc.<br />
Fig. 9: Triggering when pre-defined limit<br />
values are absolutely exceeded<br />
Fig. 10: Triggering when a relative value<br />
change is exceeded<br />
Fig. 11: Triggering when within a time period,<br />
the measurement value exceeds a relative<br />
value change
ProduCtinformation Pd- p / Pd- p plus<br />
Parameterising <strong>and</strong> reading <strong>data</strong><br />
The level <strong>data</strong> <strong>logger</strong> is configured <strong>and</strong> the stored<br />
measurement values are read conveniently using<br />
a PC or laptop with ComWin software.<br />
the level <strong>data</strong> <strong>logger</strong> is connected to the computer<br />
via the serial interface <strong>and</strong> a special connection<br />
cable. after the level <strong>data</strong> <strong>logger</strong> type has<br />
been selected, the parameterisation window<br />
appears. all settings can be seen clearly in just<br />
one single window (see fig. 1 ).<br />
for reading the <strong>data</strong>, the convenient option is<br />
available of reading with a single mouse click all<br />
new measurement <strong>data</strong> which has arrived since<br />
the last reading, <strong>and</strong> immediately showing it in<br />
graphic/table form, or reading a specific time period<br />
(see fig. 13). for a quick view of the <strong>data</strong>,<br />
only the current actual values can be shown, in<br />
order to conduct an actual value compensation,<br />
for example.<br />
Fig. 14: Comparative graphic e.g. of different levels<br />
Fig. 15: Representation of the <strong>data</strong> sequences in table form<br />
Fig. 12: Parameterisation – overview window<br />
Fig. 13: Read <strong>data</strong> from a specific time period<br />
the read <strong>data</strong> can be shown <strong>and</strong> stored in graphic or<br />
table form. for comparative representations, several<br />
curves from different level <strong>data</strong> <strong>logger</strong>s can be<br />
combined in a single graphic or table (see figs. 14<br />
<strong>and</strong> 15).<br />
the graphic representation st<strong>and</strong>s out for its simple<br />
operation <strong>and</strong> automatic axis scaling of the graphic.<br />
for professional users, a wide range of setting<br />
options are available, such as axle scaling or zoom<br />
functions.<br />
the representation in table form gives all the <strong>data</strong><br />
in the graphic shown (see fig. 15). Rapid toggling<br />
between graphic <strong>and</strong> table representations is possible<br />
with a single mouse click.<br />
With the export function, the <strong>data</strong> is stored via a<br />
converter in Excel format, or in any format specified<br />
by the customer.<br />
We offer the DataWin <strong>and</strong> MetWin solution for more<br />
comprehensive <strong>data</strong> analyses <strong>and</strong> the fully automated<br />
retrieval of all measuring systems through to<br />
measuring networks.
ProduCtinformation Pd- p / Pd- p plus<br />
Technical specifications<br />
Pd- p<br />
measuring range – level<br />
measuring range – temperature<br />
functions<br />
Storage methods<br />
memory<br />
Scope of delivery<br />
<strong>»</strong> <strong>Level</strong> <strong>data</strong> <strong>logger</strong>; cable length must be given when ordering.<br />
SOMMEr GmbH & Co KG<br />
Straßenhäuser 7<br />
a-684 Koblach<br />
tel.: +43 55 3 55989 – 0<br />
fax: +43 55 3 55989 – 19<br />
Email: office@sommer.at<br />
internet: www.sommer.at<br />
measuring range: 5, 10, 15, 0m with 1mm resolution<br />
Precision: 0.1% (fS); measuring principle / sensor: piezoresitiv<br />
measuring range: -10°C to +50°C at 0.1°C resolution<br />
Precision: 0.1% (fS); measuring principle / sensor: Pt 1000<br />
<strong>Level</strong> <strong>and</strong> water temperature<br />
Scheduled values, average values, minimum, maximum<br />
Synchronous storage: interval of seconds to 4 hours<br />
(time-synchronous)<br />
mB memory size<br />
(corresponds to approx. 600,000 measurement values)<br />
interface – digital Serial; rS 3 with 1. – 115 kBd transmission speed<br />
remote <strong>data</strong> transfer<br />
Supply<br />
Current-saving operation of the measuring site with remote<br />
<strong>data</strong> transfer due to integrated modem triggering<br />
Lithium battery: 3.6 VdC / 6 ah (can be replaced by the user)<br />
Battery life: up to 10 years (with 15-minute measuring interval)<br />
areas of application/protection type operating temperature: -10°C to +50°C; overload: 3 bar; iP 68<br />
assembly Suspension device for simply assembly in level pipes<br />
Pd- p plus (additional functions to the Pd- p)<br />
Storage methods Conditional <strong>and</strong> event-controlled storage<br />
Warning<br />
active report issuing/warning via telephone call or SmS after<br />
defined limits are exceeded<br />
measurement value retrieval via SmS retrieval regardless of location of the current actual values via SmS<br />
See the <strong>data</strong>sheet for all technical specifications<br />
Copyright<br />
© Copyright 007 Sommer. all rights reserved. Content may be changed<br />
without notice. Pictures, drawings <strong>and</strong> other graphic images are for illustration<br />
only <strong>and</strong> do not represent product configuration.<br />
Exclusion<br />
Subject to deliverability, technical changes <strong>and</strong> errors excepted.