Energy Saving

Control

System

The Hydrovar is the world’s first pump mounted

microprocessor based pumping system controller.

HYDROVAR

Series

NEW DESIGN

1,5 - 11 kW

FEATURES

● Sizes available 1,5 to 45 kW.

● Wall mounted versions available.

● Shuts off a zero demand.

● Mounted directly on standard I.E.C.

motors.

● L.C.D. display.

● Connect up to 4 pumps together.

● Two different control inputs.

● IP 54 protection.

● Anti-condensation heater.

● Choice of languages.

● Password protected.

● Hours run.

● Meets the relevant EMC European

directives.

● Switching frequency between 2,5 and

8 kHz.

The Hydrovar does much more than just

change motor speed. It truly manages

your pump performance to match a

wide range of system conditions,

allowing energy savings of up to 70%.

Due to the unique design, the Hydrovar

can be mounted or retro-fitted to any

standard I.E.C. motor.

The Hydrovar eliminates the need for:

● Complex control panels.

● System control valves.

● Large pressure accumulators.

TYPICAL EXAMPLES OF

APPLICATION

● Maintaining a constant pressure, as

in water boosting or irrigation.

● Maintains a constant flow, as in

water supply.

● Compensating for losses in a system

(following a system curve), as in heating

systems.

● Control of pump performance by

temperature sensors.

● Emptying or filling tanks by level

probes.

● Control of boiler feed water.


HYDROVAR

PROTECTIONS

● Dry running.

● Over/under voltage.

● Motor over temperature.

● Inverter over temperature.

● Pump running beyond minimum

pressure setting.

● Pump overload.

● Sensor failure.

HOW IS THE HYDROVAR

CONTROLLED?

The Hydrovar utilises a 4-20 mA signal

to regulate the motor speed in order to

meet the pre-set system requirements.

By controlling the motor in this way the

user can make substantial savings in

comparison to conventionally controlled

systems.

OUTPUTS AVAILABLE

● RS 485 interface.

● Analogue signal indicating pressure

or frequency.

● Pump run relay.

● Pump fault relay.

● Start signal for a second pump

running at constant speed.

TECHNICAL

SPECIFICATION

● Maximum frequency 60 Hz.

● Liquid temperature -20°C to 80°C

(using standard transducer).

● Maximum distance of transducer

from Hydrovar, 20 metres (can be

extended to 100 metres with use of

additional device).

● Ambient temperature 5°C to 40°C.

● Humidity, 50% at 40°C and 90% at

20°C.

TYPICAL ENERGY SAVINGS

Pump Type: Multistage SV1608F75T at a head of 80 metres

CAPACITY POWER USED POWER LENGTH TOTAL

CONSTANT SPEED

VARIABLE SPEED

SAVED

OF TIME

m3/h kW kW kW h kWh

9 5,50 3,09 2,41 2.190 5.278

14 6,71 4,81 1,90 4.380 8.322

21 7,30 7,21 0,09 2.190 197

TOTAL ANNUAL ENERGY SAVINGS

13.797

Pump Type: Inline FCE 80 - 200/110 at a head of 25 metres

CAPACITY POWER USED POWER LENGTH TOTAL

CONSTANT SPEED

VARIABLE SPEED

SAVED

OF TIME

m3/h kW kW kW h kWh

40 7,13 4,95 2,18 2.190 4.774

60 8,17 6,29 1,88 4.380 8.234

90 9,81 9,43 0,38 2.190 832

TOTAL ANNUAL ENERGY SAVINGS

13.840

36075 Montecchio Maggiore - Vicenza - Italy

Tel. 0444/707111 - Fax 0444/492166 - http://www.lowara.com

Lowara reserves the right to make modifications without prior notice. 04/02