Ballasts: T12 Electronic and High Output - GE Lighting Asia Pacific

geciasia.com

Ballasts: T12 Electronic and High Output - GE Lighting Asia Pacific

Table of Contents

T12 Electronic and High Output Ballasts

gelighting.com

Ballasts

Understanding T12 Electronic Ballasts........................14-2

ProLine ® T12

For F20 (2 ft), F30 (3 ft),

F34/F40 (4 ft) T12 Lamps....................................................... 14-3

For T12 4 ft – 8 ft

Slimline Lamps............................................................................ 14-6

T12 High Output...............................................................14-7

Wiring Diagrams..............................................................14-8

Case Dimensions..............................................................14-9

T8 Instant Start

T8 Programmed

Start

Programmed

Start Dimming

T5 Electronic

Programmed Start

T12 Electronic

& High Output

T12 Magnetic Sign

Compact

Fluorescent

See page E-1 for warranty information.

14-1

HID Electronic &

Electromagnetic


Understanding T12

Electronic Ballasts

Electronic T12

GE multivolt and dedicated voltage ProLine ® T12 high-performance ballasts are designed for

replacement of magnetic T12 electronic ballasts during maintenance or retrofits. GE multivolt

ProLine ® T12 ballasts have the same wiring and mounting requirements as standard magnetic

ballasts and provide up to 20% energy savings by simply replacing the ballast.

The DOE ballast ruling effective April 1, 2005, prevents the sale of 4 foot and 8 foot lamp

electro magnetic ballasts that operate T12 lamps and do not meet federal ballast efficiency

requirements. GE ProLine ® T12 electronic ballasts meet the DOE minimum ballast efficiency

requirements and also allow facility managers to reduce ballast maintenance inventories by

consolidating the number of ballasts needed. GE ProLine ® T12 ballasts operate both energysaving

and standard wattage lamps and are also multi-voltage (120-277V). With 2 ballasts, the

multi-voltage ProLine ® T12 can consolidate over 40 different magnetic ballasts.

Performance Features

GE240RSMVN and GE240RS120 comply

with FCC for residential use

• Low-profile and lightweight housing

simplifies installation and reduces

transportation costs (GE240 = 1.3 lbs. lighter

than magnetic; GE260 = 5.3 lbs. lighter than

magnetic)

• Parallel operation — if one lamp fails,

others remain lit

• Significantly quieter than magnetic

High-frequency operation virtually

eliminates lamp flickering typical in T12

electromagnetic systems

• Five-year limited ballast warranty

Electromagnetic T12

• Complete line of ballasts for 2-to-8 foot

lamps, circleline and high-output lamps

• 100% thermally protected

High-grade lamination steel assures lowest

wattage loss

• UL, CSA and/or cUL approved

• 888-GEBALLAST on every ballast

• Two-year limited ballast warranty

Color-Coded Ballast and Outer Box Labels

120V – Yellow

277V – Red

Packaging

• Standard 10 packs

• IP Packs – individually packed with

instructions

• DIY – shrink-wrapped and tray-packed

with instructions

GE Ballast LFL magnetic nomenclature

G E M - 2 3 2 - H O - R S - 1 2 0 - D I Y

14-2

GE Ballast

M = Electromagnetic

Ballast

GEH = HID

Maximum number of

lamps supported by

this ballast: 1, 2, 3, 4

Lamp Watts

(Primary Lamp)

T8 = 32 – 4 foot,

59 – 8 foot

T12 = 40 – 4 foot,

60 – 8 foot

T12 Electronic =

40 – 2-4 foot, 2 pin

60 – 4-8 foot, 1 pin

96 – 4-8 foot HO,

2 pin

T12 Magnetic =

40 – 2-4 foot, 2 pin

96 – 4-8 foot, 2 pin

IS = Instant Start,

default if not shown

RS = Rapid Start

PH = Preheat

PT= Preheat/Trigger

H = Hybrid

D50 = Dimming (min level)

HO = High Output

VHO = Very High Output

120V – Yellow

277V – Red

220V – Green

240V – Orange

347 – Gray

Pack Type

IP = Individual corrugated

box per ballast

84T = Pallet bulk pack

(84=840, 42=420 ballasts)

DIY = Shrinkwrap ballast in

tray pack

DIY72 = Shrinkwrap ballast

in pallet pack (Qty)

No extension = 10 pack

See page E-1 for warranty information.


gelighting.com

ProLine ® T12

T12 Electronic and High Output Ballasts For F20 (2 ft), F30 (3 ft), F34/F40 (4 ft) T12 Lamps

Ballasts

74472 – GE240RS-MV-N (replaces 24107)

ProLine ® T12 Multivolt 120V – 277V

2 or 1 – F40 or F34T12 Rapid Start 120 to 277 “N” BF ProLine ® T12

General characteristics

Ballast Type

Electronic – Programmed/ Rapid Start

Starting Method

Rapid start

Lamp Wiring

Parallel

Line Voltage Regulation (+/-) 10%

Ambient Temperature (MAX)

Case Temperature (MAX)

70°C (158°F)

Ballast Factor

Normal

Power Factor Correction

Active

Sound Rating

A (20-24 decibels)

Enclosure Type

Metal

Additional Info

Auto-restart, Thermally protected

Electrical characteristics

Supply Current Frequency

60 Hz

Order information

Std. pack Pallet Pack DIY Pack IP Pack

74472 74473 (replaces 24773)

Specifications by lamp and wattage

Safety and performance

High-performance electronic ballast for all general fluorescent applications

• Multi-voltage technology handles voltage from 120 to 277V

• Light weight, low-profile housing

• Parallel lamp operation means system maintenance is easier to manage

Dimensions

Wiring diagram – LFL PS2 – see example on page 14-8

Case dimensions – Ref Drawing B1 – see page 14-9

Length (L)

Width (W)

Height (H)

Mounting dimensions

Mount Length (M)

Mount Width (X or F)

Mount Slots (MS)

Weight

Exit Type

Remote mounting distance to lamp

Remote Mounting Wire Gauge

Lead lengths

Yellow

Blue

Red

Black

White

9.5 in (241 mm)

1.3 in (33 mm)

1.18 in (30 mm)

8.9 in (226 mm)

1.18 in (30 mm)

0.3 in (8 mm)

1.06 lbs

Side

18 ft

18 AWG

Length (± 1 in.)

48.0 in (1219 mm)

33.0 in (838 mm)

33.0 in (838 mm)

25.0 in (635 mm)

25.0 in (635 mm)

Lamp # of Lamps Line Volts System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor% (>=) Crest Factor (


ProLine ® T12

T12 Electronic and High Output Ballasts For F20 (2 ft), F30 (3 ft), F34/F40 (4 ft) T12 Lamps

97498 – GE240RS120

ProLine ® T12 120V

2 – F40 or F34T12 Rapid Start 120V “N” BF ProLine ® T12

General characteristics

Ballast Type

Electronic – Programmed / Rapid Start

Starting Method

Rapid start

Lamp Wiring

Series

Line Voltage Regulation (+/-) 10%

Ambient Temperature (MAX)

221°F (105°C)

Case Temperature (MAX)

70°C (158°F)

Ballast Factor

Normal

Power Factor Correction

Passive

Sound Rating

A (20-24 decibels)

Additional Info

Auto-restart, Thermally protected

Electrical characteristics

Supply Current Frequency

50 Hz/60 Hz

Order information

Std. pack Pallet Pack DIY Pack IP Pack

97498 97499

High-performance electronic ballast for all general fluorescent applications

• Light weight, low-profile housing

Dimensions

Wiring diagram – LFL PS2 – see example on page 14-8

Case dimensions – Ref Drawing B1 – see page 14-9

Length (L)

Width (W)

Height (H)

Mounting dimensions

Mount Length (M)

Mount Width (X or F)

Mount Slots (MS)

Weight

Exit Type

Remote Mounting Distance to Lamp

Remote Mounting Wire Gauge

Lead lengths

White and Black

Blue and Red

Yellow

Yellow

9.5 in (241 mm)

1.3 in (33 mm)

1.0 in (25 mm)

8.9 in (226 mm)

0.9 in (22 mm)

0.3 in (8 mm)

1.38 lbs

Side

18 ft

18 AWG

Length (± 1 in)

25 in (635 mm)

33 in (838 mm)

48 in (1219 mm)

36 in (914 mm)

Specifications by lamp and wattage

Lamp # of Lamps Line Volts System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Power Factor % (>=) Crest Factor (


gelighting.com

ProLine ® T12

T12 Electronic and High Output Ballasts For F20 (2 ft), F30 (3 ft), F34/F40 (4 ft) T12, F40T10 Lamps

Ballasts

24109 – GE340RS-MV-N

ProLine ® T12 Multivolt 120V – 277V

3 or 2 – F40 or F34T12 Rapid Start 120 to 277 ProLine ® T12

General characteristics

Ballast Type

Electronic – Programmed / Rapid Start

Starting Method

Rapid start

Lamp Wiring

Parallel

Line Voltage Regulation (+/-) 10%

Ambient Temperature (MAX)

105°F (41°C)

Case Temperature (MAX)

70°C (158°F)

Ballast Factor

Normal

Power Factor Correction

Active

Sound Rating

A (20-24 decibels)

Additional Info

Auto-restart, Thermally protected

Electrical characteristics

Supply Current Frequency

50 Hz/60 Hz

Order information

Std. pack Pallet Pack DIY Pack IP Pack

24109 24774

Specifications by lamp and wattage

High-performance electronic ballasts for all general fluorescent applications

• Multi-voltage technology handles voltage from 120 to 277V

• Lightweight, low-profile housing

• Parallel lamp operation means system maintenance is easier to manage

Dimensions

Wiring diagram – LFL PS3 – see example on page 14-8

Case dimensions – Ref Drawing ST – see page 14-9

Length (L)

Width (W)

Height (H)

Mounting dimensions

Mount Length (M)

Mount Width (X or F)

Mount Slots (MS)

Weight

Exit Type

Remote Mounting Distance to Lamp

Remote Mounting Wire Gauge

Lead lengths

Blue and Red

Red/White

White and Black

Yellow

9.5 in (241 mm)

2.3 in (60 mm)

1.5 in (39 mm)

8.9 in (226 mm)

1.6 in (40 mm)

0.3 in (8 mm)

2.40 lbs

Side

18 ft

18 AWG

Length (± 1 in)

33 in (838 mm)

33 in (838 mm)

25 in (635 mm)

48 in (1219 mm)

Lamp # of Lamps Line Volts System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) Crest Factor (


ProLine ® T12

T12 Electronic and High Output Ballasts For T12 4 ft – 8 ft Slimline Lamps

74474 – GE-260IS-MV-N (replaces 24108)

ProLine ® T12 Multivolt 120V – 277V

2 or 1 – F96T12 Instant Start 120 to 277

High-performance electronic ballasts for all general fluorescent applications

• Instant start electronic ballast for long lamp starting cycles and low initial cost

• Multi-voltage technology handles voltage from 120 to 277V

• Lightweight, low-profile housing

• Parallel lamp operation means system maintenance is easier to manage

General characteristics

Ballast Type

Electronic - Multivolt Instant Start

Starting Method

Instant start

Lamp Wiring

Parallel

Line Voltage Regulation (+/-) 10 %

Ambient Temperature (MAX)

Case Temperature (MAX)

70 °C (158 °F)

Ballast Factor

Normal

Power Factor Correction

Active

Sound Rating

A (20-24 decibels)

Enclosure Type

Metal

Additional Info

Auto-restart, Thermally protected

Electrical characteristics

Supply Current Frequency

50Hz/60 Hz

Order information

10 Pack Pallet Pack DIY Pack IP Pack

74474 74475 (replaces 24776)

Specifications by lamp and wattage

Dimensions

Wiring diagram – LFL 14 – see example on page 14-8

Case dimensions – Ref Drawing B1 – see page 14-9

Length (L)

Width (W)

Height (H)

Mounting dimensions

Mount Length (M)

Mount Width (X or F)

Mount Slots (MS)

Weight

Exit Type

Remote Mounting Distance to Lamp

Remote Mounting Wire Gauge

Lead lengths

Black

White

Red

Blue

9.5 in (241 mm)

1.7 in (43 mm)

1.18 in (30 mm)

8.9 in (226 mm)

1.18 in (30 mm)

0.3 in (8 mm)

2.40 lbs

Side

18 ft

18 AWG

Length (± 1 in.)

25.0 in (635 mm)

25.0 in (635 mm)

59.0 in (1499 mm)

67.0 in (1702 mm)

Lamp # of Lamps Line Volts System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor% (>=) Crest Factor (


T12 High Output

T12 Electronic and High Output Ballasts

gelighting.com

Ballasts

75671 – GE296HO-MV-N

T12 High Output ProLine ® T12 Multivolt 120V – 277V

2 or 1 – F96T12 HO RS 120 to 277 Multivolt ProLine ®

General characteristics

Ballast Type

Electronic – Programmed/ Rapid Start

Starting Method

Rapid start

Lamp Wiring

Series

Line Voltage Regulation (+/-) 10%

Ambient Temperature (MAX)

105°F (41°C)

Case Temperature (MAX)

75°C (167°F)

Ballast Factor

Normal

Power Factor Correction

Active

Sound Rating

A (20-24 decibels)

Additional Info

Auto-restart, Thermally protected

Electrical characteristics

Supply Current Frequency

50 Hz/60 Hz

Order information

Std. pack Pallet Pack DIY Pack IP Pack

75671 72109

Specifications by lamp and wattage

Safety and performance

cUL Listed UL Listed FCC Part 18 (Class A) Non Consumer

Dimensions

Wiring diagram – LFL PS2 – see example on page 14-8

Case dimensions – Ref Drawing SL – see page 14-9

Length (L)

Width (W)

Height (H)

Mounting dimensions

Mount Length (M)

Mount Width (X or F)

Mount Slots (MS)

Weight

Exit Type

11.75 in (299 mm)

2.15 in (55 mm)

1.61 in (41 mm)

11.0 in (279 mm)

2.15 in (55 mm)

Side

Remote Mounting Distance to Lamp*

Remote Mounting Wire Gauge

* See gelighting.com for wire lengths. Different for 10 pg vs. DIY pack.

Lamp # of Lamps Line Volts System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor % (>=) Crest Factor (


Wiring Diagrams

T12 Electronic and High Output Ballasts

LFL PS2

LFL PS3

LFL 14 LFL 2

14-8 See page E-1 for warranty information.


Case Dimensions

T12 Electronic and High Output Ballasts

gelighting.com

Ballasts

ST

B1

T8 Instant Start

T8 Programmed

Start

D10, 15, 29 SL

Programmed

Start Dimming

T5 Electronic

Programmed Start

T12 Electronic

& High Output

T12 Magnetic Sign

Compact

Fluorescent

See page E-1 for warranty information.

14-9

HID Electronic &

Electromagnetic


T12 Electronic and High Output Ballasts

Notes

14-10 See page E-1 for warranty information.

More magazines by this user