Underst<strong>and</strong>ing <strong>T12</strong><br />

<strong>Electronic</strong> <strong>Ballasts</strong><br />

<strong>Electronic</strong> <strong>T12</strong><br />

<strong>GE</strong> multivolt <strong>and</strong> dedicated voltage ProLine ® <strong>T12</strong> high-performance ballasts are designed for<br />

replacement of magnetic <strong>T12</strong> electronic ballasts during maintenance or retrofits. <strong>GE</strong> multivolt<br />

ProLine ® <strong>T12</strong> ballasts have the same wiring <strong>and</strong> mounting requirements as st<strong>and</strong>ard magnetic<br />

ballasts <strong>and</strong> provide up to 20% energy savings by simply replacing the ballast.<br />

The DOE ballast ruling effective April 1, 2005, prevents the sale of 4 foot <strong>and</strong> 8 foot lamp<br />

electro magnetic ballasts that operate <strong>T12</strong> lamps <strong>and</strong> do not meet federal ballast efficiency<br />

requirements. <strong>GE</strong> ProLine ® <strong>T12</strong> electronic ballasts meet the DOE minimum ballast efficiency<br />

requirements <strong>and</strong> also allow facility managers to reduce ballast maintenance inventories by<br />

consolidating the number of ballasts needed. <strong>GE</strong> ProLine ® <strong>T12</strong> ballasts operate both energysaving<br />

<strong>and</strong> st<strong>and</strong>ard wattage lamps <strong>and</strong> are also multi-voltage (120-277V). With 2 ballasts, the<br />

multi-voltage ProLine ® <strong>T12</strong> can consolidate over 40 different magnetic ballasts.<br />

Performance Features<br />

• <strong>GE</strong>240RSMVN <strong>and</strong> <strong>GE</strong>240RS120 comply<br />

with FCC for residential use<br />

• Low-profile <strong>and</strong> lightweight housing<br />

simplifies installation <strong>and</strong> reduces<br />

transportation costs (<strong>GE</strong>240 = 1.3 lbs. lighter<br />

than magnetic; <strong>GE</strong>260 = 5.3 lbs. lighter than<br />

magnetic)<br />

• Parallel operation — if one lamp fails,<br />

others remain lit<br />

• Significantly quieter than magnetic<br />

• <strong>High</strong>-frequency operation virtually<br />

eliminates lamp flickering typical in <strong>T12</strong><br />

electromagnetic systems<br />

• Five-year limited ballast warranty<br />

Electromagnetic <strong>T12</strong><br />

• Complete line of ballasts for 2-to-8 foot<br />

lamps, circleline <strong>and</strong> high-output lamps<br />

• 100% thermally protected<br />

• <strong>High</strong>-grade lamination steel assures lowest<br />

wattage loss<br />

• UL, CSA <strong>and</strong>/or cUL approved<br />

• 888-<strong>GE</strong>BALLAST on every ballast<br />

• Two-year limited ballast warranty<br />

Color-Coded Ballast <strong>and</strong> Outer Box Labels<br />

120V – Yellow<br />

277V – Red<br />

Packaging<br />

• St<strong>and</strong>ard 10 packs<br />

• IP Packs – individually packed with<br />

instructions<br />

• DIY – shrink-wrapped <strong>and</strong> tray-packed<br />

with instructions<br />

<strong>GE</strong> Ballast LFL magnetic nomenclature<br />

G E M - 2 3 2 - H O - R S - 1 2 0 - D I Y<br />

14-2<br />

<strong>GE</strong> Ballast<br />

M = Electromagnetic<br />

Ballast<br />

<strong>GE</strong>H = HID<br />

Maximum number of<br />

lamps supported by<br />

this ballast: 1, 2, 3, 4<br />

Lamp Watts<br />

(Primary Lamp)<br />

T8 = 32 – 4 foot,<br />

59 – 8 foot<br />

<strong>T12</strong> = 40 – 4 foot,<br />

60 – 8 foot<br />

<strong>T12</strong> <strong>Electronic</strong> =<br />

40 – 2-4 foot, 2 pin<br />

60 – 4-8 foot, 1 pin<br />

96 – 4-8 foot HO,<br />

2 pin<br />

<strong>T12</strong> Magnetic =<br />

40 – 2-4 foot, 2 pin<br />

96 – 4-8 foot, 2 pin<br />

IS = Instant Start,<br />

default if not shown<br />

RS = Rapid Start<br />

PH = Preheat<br />

PT= Preheat/Trigger<br />

H = Hybrid<br />

D50 = Dimming (min level)<br />

HO = <strong>High</strong> <strong>Output</strong><br />

VHO = Very <strong>High</strong> <strong>Output</strong><br />

120V – Yellow<br />

277V – Red<br />

220V – Green<br />

240V – Orange<br />

347 – Gray<br />

Pack Type<br />

IP = Individual corrugated<br />

box per ballast<br />

84T = Pallet bulk pack<br />

(84=840, 42=420 ballasts)<br />

DIY = Shrinkwrap ballast in<br />

tray pack<br />

DIY72 = Shrinkwrap ballast<br />

in pallet pack (Qty)<br />

No extension = 10 pack<br />

See page E-1 for warranty information.