ProLine ® <strong>T12</strong><br />

<strong>T12</strong> <strong>Electronic</strong> <strong>and</strong> <strong>High</strong> <strong>Output</strong> <strong>Ballasts</strong> For <strong>T12</strong> 4 ft – 8 ft Slimline Lamps<br />

74474 – <strong>GE</strong>-260IS-MV-N (replaces 24108)<br />

ProLine ® <strong>T12</strong> Multivolt 120V – 277V<br />

2 or 1 – F96<strong>T12</strong> Instant Start 120 to 277<br />

• <strong>High</strong>-performance electronic ballasts for all general fluorescent applications<br />

• Instant start electronic ballast for long lamp starting cycles <strong>and</strong> low initial cost<br />

• Multi-voltage technology h<strong>and</strong>les voltage from 120 to 277V<br />

• Lightweight, low-profile housing<br />

• Parallel lamp operation means system maintenance is easier to manage<br />

General characteristics<br />

Ballast Type<br />

<strong>Electronic</strong> - Multivolt Instant Start<br />

Starting Method<br />

Instant start<br />

Lamp Wiring<br />

Parallel<br />

Line Voltage Regulation (+/-) 10 %<br />

Ambient Temperature (MAX)<br />

Case Temperature (MAX)<br />

70 °C (158 °F)<br />

Ballast Factor<br />

Normal<br />

Power Factor Correction<br />

Active<br />

Sound Rating<br />

A (20-24 decibels)<br />

Enclosure Type<br />

Metal<br />

Additional Info<br />

Auto-restart, Thermally protected<br />

Electrical characteristics<br />

Supply Current Frequency<br />

50Hz/60 Hz<br />

Order information<br />

10 Pack Pallet Pack DIY Pack IP Pack<br />

74474 74475 (replaces 24776)<br />

Specifications by lamp <strong>and</strong> wattage<br />

Dimensions<br />

Wiring diagram – LFL 14 – see example on page 14-8<br />

Case dimensions – Ref Drawing B1 – see page 14-9<br />

Length (L)<br />

Width (W)<br />

Height (H)<br />

Mounting dimensions<br />

Mount Length (M)<br />

Mount Width (X or F)<br />

Mount Slots (MS)<br />

Weight<br />

Exit Type<br />

Remote Mounting Distance to Lamp<br />

Remote Mounting Wire Gauge<br />

Lead lengths<br />

Black<br />

White<br />

Red<br />

Blue<br />

9.5 in (241 mm)<br />

1.7 in (43 mm)<br />

1.18 in (30 mm)<br />

8.9 in (226 mm)<br />

1.18 in (30 mm)<br />

0.3 in (8 mm)<br />

2.40 lbs<br />

Side<br />

18 ft<br />

18 AWG<br />

Length (± 1 in.)<br />

25.0 in (635 mm)<br />

25.0 in (635 mm)<br />

59.0 in (1499 mm)<br />

67.0 in (1702 mm)<br />

Lamp # of Lamps Line Volts System Watts Nom. Line Current System Ballast Factor Ballast Efficacy Factor Power Factor% (>=) Crest Factor (