Highlights

Feature Highlights

• Signal-acquisition advances,

such as Cubic Spline and

Incremental Median

Updating to help eliminate

baseline wander and STsegment

distortion to

generate clear, well-defined

ECGs

• Optional full-colour display

screen makes viewing better

than with monochrome

• 15-lead acquisition, storage

and analysis

• Optional ACI-TIPI (Acute

Cardiac Ischemia Time-

Insensitive Predictive

Instrument) generates a

numerical score representing

the probability that the

patient has Acute Cardiac

Ischemia

• Enhanced pacemaker-

detection software improves

sensitivity to artificially

paced hearts

• Extensive customization

from display to final-report

formatting accommodates

the preferences of

individual users

MAC ® 5000 ECG SYSTEM

WITH STRESS OPTION

GE Medical Systems Information Technologies has combined its

most advanced resting ECG system with equally sophisticated exercisetesting

capabilities in a single, compact system.

The MAC 5000 incorporates many of the features of our leadingedge

exercise testing technologies to position your facility as the

forefront of stress testing – including a broad collection of proven

algorithms and exercise test protocols.

Advanced algorithm capabilities include true, 12-lead ECG computer

analysis and interpretation, P-wave signal averaging, late potential

analysis and 15-lead ECG analysis – for effective management of

ventricular arrhythmia, atrial arrhythmia and chest pain. The 12SL

algorithm offers both adult and pediatric interpretive ECG and

gender-specific analysis for the detection of acute MI for female

patients.

The MAC 5000 with stress option delivers seamless, bidirectional

network communication to the Catalyst MUSE ® Information System.

This speeds archiving, retrieval and management of patient data. This

connectivity, combined with the inherent performance of the MAC

5000 makes it the system of choice for state-of-the-art resting ECG

and exercise testing.


Performance Specifications

Processing

Communications

Display

Writer

Keyboard

Electrical

Physical Specifications

Environmental Specifications

Certification

Ordering Information

European Headquarters

GE Medical Systems

Information Technologies GmbH

P.O. Box 60 02 65

79032 Freiburg • Germany

Tel. +49 761 45 43 - 0

Fax +49 761 45 43 - 233

Specifications

MAC ® 5000 ECG SYSTEM

WITH STRESS OPTION

* without cart ** paper discolouration may occur at higher temperatures

Instrument type: Microprocessor augmented automatic electrocardiograph; 14-leadwire acquisition with

programmable lead configuration

ECG Analysis Frequency: 500 Hz; ST Measurements: ST amplitudes, slope, ST/HR slope, ST/HR loops

E, J and Post-J Point: Manual and computer selected; Signal Processing Technique: Incremental median updating

Baseline Correction: Cubic Spline; QRS Detection and Analysis: Manual lead selection

ECG Output: Real-time ECG/QRS beep/TTL synchronization output

Heart Rate: Automatic arrhythmia detection and documentation

Heart Rate Meter: 30 to 300 BPM ±10% or 5 BPM. HR outside this range will not be displayed

ECG Interpretation: 12SL adult and pediatric ECG analysis

MAC ® and Catalyst MUSE ® System compatible; Optional: Modem and Fax transmission, Remote Retrieval (Remote Query)

Interfaces: 2 analog and 1 TTL (trigger) output

Stress: ST scan/median complexes, ventricular ectopic/min counter, 3 to 5 waveforms, lead check torso and

12 leads, interpretation, time-of-day clock, patient name, warning messages and prompts, arrhythmia documentation

Resting: Heart rate, patient name, ID, clock, waveforms, lead labels, speed, gain and filter settings, warning

messages, prompts and help messages

Display Type: 264 mm (10.4 in) diagonal graphics backlit AM LCD

Display Resolution: 640 x 480 pixels with waveform enhancement; Exercise Protocols: 8 configurable total,

6 are preset: Bruce, modified Bruce, Naughton, Ergometer, Cornell ST/HR and Ergometer ramp

Writer Technology: Thermal dot array; Writer Speeds: 5, 12.5, 25 & 50 mm/s (same as displayed)

Number of Traces: 3, 6, 12 or 15, user-selectable (same as displayed)

Writer Sensitivity/Gain: 2.5, 5, 10, 20, 10/5 (split calibration) mm/mV (same as displayed)

Writer Speed Accuracy: ±2%; Writer Amplitude Accuracy: ±5%

Writer Resolution: Horizontal 1000 dpi @ 25 mm/s, 200 dpi vertical

Paper Type: Thermal, Z-fold, perforated, 300 sheets/pack

Paper Size: US Size: 214.63 mm x 280 mm (8.45 in x 11 in); A4 Size: 210 mm x 297.5 mm (8.27 in x 11.7 in)

Type: Sealed elastomer with soft function keys, alphanumeric keys, writer controls and TrimPad cursor

controls, dedicated stress test keys

Power Supply: AC or battery operation; Voltage: 100 to 240 VAC +10, –15%

Current: 0.5A @ 115 VAC, 0.3A @ 240 VAC, typical; Frequency: 50 to 60 Hz ± 10%

Battery Type: User replaceable, 18V @ 3.5 AH ± 15% rechargeable NiMH

Battery Capacity: 100 single page reports (typical) or 6 hours continuous display (without printing)

Battery Charge Time: Approximately 4.5 hours from total discharge (with display off)

Height: 9.4 cm (3.7 in)* with display closed; Width: 38.1 cm (15 in)*; Depth: 35.1 cm (13.8 in)*;

Weight: Approximately 6.8 kg (15 lb)* including battery without paper

Temperature: Operating: 10° to 40° C (50° to 104° F)**; Transport/Storage: –40° to 70° C (–40° to 150°F)**

Humidity: Operating: 20% to 95% RH non-condensing; Transport/Storage: 15% to 95% RH non-condensing

Pressure: Operating: 700 to 1060 hPA; Transport/Storage: 500 to 1060 hPA

UL classification, CSA classification, CE marking indicating compliance with the Medical Device Directive

93/42/EEC, CB certificate

Available in: Dutch, English, French, German, Italian, Spanish, Swedish and Japanese

World Headquarters

GE Medical Systems

Information Technologies, Inc.

8200 West Tower Avenue

Milwaukee, WI 53223 • USA

Tel. +1 414 355 5000

Fax +1 414 355 3790

Asia Pacific

GE Medical Systems Hong Kong Ltd.

11th Floor, The Lee Gardens, 33 Hysan Ave.

Causeway Bay • Hong Kong

Tel. +852 2100 6300

Fax +852 2100 6292

gemedical.com

2009208-002-2002.01-pdf-V1.0 Printed in Germany Printed on chlorine-free paper. Subject to change due to technical advance.

More magazines by this user
Similar magazines