<strong>Modular</strong><br />

<strong>Modular</strong><br />

devices


<strong>Modular</strong> <strong>Devices</strong> -<br />

Indicators and Push Buttons<br />

The new range of indicator<br />

lights and push buttons<br />

replaces and expands upon<br />

the whole SV range and is<br />

composed of the following<br />

three families<br />

• Indicator Lights in various<br />

colours such as red,<br />

green, orange, blue and<br />

clear.<br />

• Push Buttons in various<br />

contact types (NO, NC,<br />

NO+NC in 1 or 2 poles)<br />

and buttons (latching or<br />

impulse).<br />

• Indicator Lights and Push<br />

Buttons, an association of<br />

the above two solutions.<br />

New LED technology provides longer<br />

life.<br />

Updated and modernised<br />

appearance.<br />

Integrated label holder.<br />

352


Latching relays 354<br />

<strong>Modular</strong><br />

devices<br />

Relays 356<br />

Interface relays 356<br />

Contactors<br />

& override contactors 357<br />

Low noise contactors 358<br />

Electromechanical and<br />

digital timers selection<br />

guide 359<br />

Electromechanical<br />

time switches 360<br />

Digital time switches 362<br />

4 channel digital<br />

time switches 362<br />

Light sensitive switch 364<br />

Light sensitive<br />

programmer 364<br />

Presence Detectors 365<br />

Delay timers 367<br />

Time lag switches 368<br />

Emergency<br />

lighting module 369<br />

Switch disconnector 374<br />

Trip Free Switches 375<br />

2 way / centre-off<br />

changeover<br />

modular switches 376<br />

Pushbuttons -<br />

Impulse 377<br />

Pushbuttons -<br />

Latching 378<br />

Indicator lights 381<br />

Transformers,<br />

bells and buzzers 381<br />

Analogue voltmeters,<br />

ammeters 382<br />

Digital voltmeters 383<br />

Current transformers 385<br />

Selector switches<br />

for voltmeters<br />

and ammeters 386<br />

kiloWatt hour meters 387<br />

Hours counter 387<br />

Control Relays 388<br />

353


Latching relays<br />

Description<br />

For the control of lighting<br />

circuits in private buildings,<br />

small industry buildings and<br />

administration buildings.<br />

Latching relays - operate when<br />

impulsed by a signal voltage.<br />

The impulse can be provided via<br />

a pushbutton or switch. The first<br />

pulse operates the relay and<br />

latches it into its set (opposite)<br />

state, the next operation of the<br />

pushbutton returns the relay into<br />

its reset (original) state.<br />

The latching relays are built to<br />

add on optionally the following<br />

auxiliaries :<br />

- an auxiliary for centralised<br />

ON/OFF control EPN050<br />

- an auxiliary contact for<br />

remote signalling EPN051<br />

- an auxiliary for multi levelled<br />

centralised control EPN052<br />

- an auxiliary for control by<br />

maintained contact EPN053.<br />

Connection capacity<br />

10▫ rigid cables<br />

6▫ flexible cables<br />

Conform to standard EN669-1<br />

and EN669-2-2<br />

For technical details<br />

see page 390<br />

Designation Type Coil Coil Power Width in I Pack Cat.<br />

VAC VDC Circuit 17.5mm qty. ref.<br />

50/60Hz<br />

AC1<br />

Latching relays 1NO 230 110 16A-250V 1 1 EPN510<br />

A1<br />

1<br />

48 24 16A-250V 1 1 EPN501<br />

A2<br />

2<br />

24 12 16A-250V 1 1 EPN513<br />

12 - 16A-250V 1 1 EPN511<br />

8 - 16A-250V 1 1 EPN512<br />

A1<br />

1<br />

3<br />

2NO 230 110 16A-250V 1 1 EPN520<br />

A2<br />

2<br />

4<br />

110 48 16A-250V 1 1 EPN523<br />

EPN510<br />

48 24 16A-250V 1 1 EPN526<br />

24 12 16A-250V 1 1 EPN524<br />

12 - 16A-250V 1 1 EPN521<br />

8 - 16A-250V 1 1 EPN522<br />

A1<br />

1<br />

3<br />

1NC+1NO 230 110 16A-250V 1 1 EPN515<br />

A2<br />

2<br />

4<br />

110 48 16A-250V 1 1 EPN516<br />

48 24 16A-250V 1 1 EPN503<br />

EPN515<br />

24 12 16A-250V 1 1 EPN518<br />

12 - 16A-250V 1 1 EPN519<br />

A1<br />

1<br />

3<br />

5<br />

7<br />

4NO 230 110 16A-400V 2 1 EPN540<br />

A2<br />

2<br />

4<br />

6<br />

8<br />

48 24 16A-400V 2 1 EPN548<br />

24 12 16A-400V 2 1 EPN541<br />

EPN525<br />

A1<br />

1<br />

3<br />

5<br />

7<br />

2NC+2NO 230 110 16A-250V 2 1 EPN525<br />

A2<br />

2<br />

4<br />

6<br />

8<br />

24 12 16A-250V 2 1 EPN528<br />

A1<br />

1<br />

3<br />

5<br />

7<br />

3NO+1NC 230 110 16A-400V 2 1 EPN546<br />

EPN540<br />

A2<br />

2<br />

4<br />

6<br />

8<br />

354


Latching relays auxiliaries<br />

Auxiliaries for centralised<br />

control<br />

The EPN050 allows the<br />

centralised control of several<br />

light sources which can be<br />

turned on or off simultaneously<br />

the separate switching by<br />

pushing the pushbuttons, which<br />

are connected with the latching<br />

relay, remains possible.<br />

The EPN052 allows a generic<br />

central control of individual<br />

central on/off EPN050<br />

Auxiliary contact<br />

A remote signalling can be<br />

realised with the auxiliary<br />

contact EPN051.<br />

Auxiliary for control by<br />

maintained contact<br />

When control devices with<br />

permanent impulse are<br />

externally driven, e.g. time<br />

switches or limit switches, an<br />

impulse control directly to the<br />

latching relay’s coil is possible<br />

with the auxiliary contact EP 053.<br />

Connection latching relay +<br />

auxiliary<br />

Several auxiliaries can be<br />

combined with the latching relay.<br />

Connection capacity<br />

10▫ rigid cables<br />

6▫ flexible cables<br />

For technical details<br />

see page 392<br />

<strong>Modular</strong><br />

devices<br />

Designation Voltage supply Width in I Pack Cat.<br />

17.5mm qty. ref.<br />

Auxiliary for 24 to 230V AC 1/2 1 EPN050<br />

centralised control<br />

11<br />

12 14<br />

EPN050<br />

Auxiliary contact 2A - 250 V AC 1/2 1 EPN051<br />

21 23<br />

22 24<br />

EPN051<br />

Auxiliary for 24 to 230V AC 1/2 1 EPN052<br />

multi levelled<br />

centralised control<br />

31 33<br />

32 34<br />

EPN052<br />

Auxiliary for 24 to 230V AC 1/2 1 EPN053<br />

control by<br />

maintained contact<br />

11<br />

12 14<br />

EPN053<br />

355


Relays<br />

Description<br />

To provide command of low<br />

power circuits max 16A;<br />

associated with pushbuttons<br />

switches, time switches etc to<br />

provide for remote control applications.<br />

For the command of high power<br />

circuits (25, 40, 63Amps) use<br />

contactors as shown on<br />

page 357.<br />

The relays will accept an<br />

auxiliary contact for remote<br />

signalling applications.(EP071)<br />

For the command of VLV circuits<br />

use interface relays EN145 and<br />

EN146.<br />

For technical details<br />

see page 393<br />

Designation Type Coil Power Width in I Pack Cat.<br />

Circuit 17.5mm qty. ref.<br />

AC1<br />

Relays 1NC+1NO 230V 50Hz 16A-250V 1 12 ER120<br />

24V 50Hz 16A-250V 1 12 ER123<br />

12V 50Hz 16A-250V 1 12 ER124<br />

2NC+2NO 230V 50Hz 16A-250V 2 1 ER135<br />

ER120<br />

24V 50Hz 16A-250V 2 1 ER138<br />

12V 50Hz 16A-250V 1 1 ER139<br />

Auxiliary contact 2A-250V 1/2 1 EP071<br />

ER138<br />

Interface relays<br />

Description<br />

To interface between low voltage<br />

and very low voltage circuits to<br />

ensure galvanic isolation<br />

between LV and VLV to 4kV.<br />

Application<br />

Interface between fire alarm,<br />

burglar alarm and other VLV<br />

systems and main distribution<br />

circuits.<br />

Connection capacity<br />

6▫ rigid cables<br />

4▫ flexible cables<br />

For technical details<br />

see page 394<br />

Designation Characteristics Width in I Pack Cat.<br />

17.5mm qty. ref.<br />

Interface relays coil voltage : 1 1 EN145<br />

VLV/LV 1 way<br />

10 to 26V AC/DC<br />

A1 1<br />

output : 1 changeover contact<br />

max. 5A 230V~ -<br />

A2 2 4<br />

min. 10mA - 12V DC<br />

EN145<br />

356<br />

VLV/LV 1 way coil voltage : 1 1 EN146<br />

A1 1<br />

230V~ 50Hz<br />

output : 1 changeover contact<br />

A2 2 4<br />

max. 5A 230V~<br />

min. 10mA - 12V DC


Contactors and override contactors<br />

Description<br />

Contactors<br />

For the remote switching and<br />

control of power circuits<br />

(25A-63A AC1)<br />

Override contactors<br />

allows : - permanent ON<br />

- permanent OFF<br />

Technical data<br />

The choice of contactor<br />

depends upon a number of<br />

parameters, e.g.<br />

- the nature of the supply.<br />

- the power it is switching.<br />

- the characteristics of the load.<br />

- the control voltage required.<br />

- number of operations<br />

All contactors ratings are for<br />

AC1 loads only – if the load<br />

differs from AC1 the contactor<br />

may need de-rating<br />

The use of LZ 060<br />

(heat dissipation inserts)<br />

between all contactors<br />

installed or between<br />

contactors and adjacent<br />

devices is recommended.<br />

Options<br />

Contact choice<br />

- normally open (NO)<br />

- normally closed (NC)<br />

LZ 060 heat dissipation inserts.<br />

Auxiliary<br />

25A contactors will accept<br />

auxiliary, EP 071 contact.<br />

For technical details<br />

see pages 393-395<br />

<strong>Modular</strong><br />

devices<br />

Designation Type Coil Power Width in I Pack Standard Override<br />

AC Circuit 17.5mm qty. cat. ref. cat. ref.<br />

50/60Hz 50/60Hz<br />

Contactors 1NO 230V 25A-250V 1 1 ES110 ES110A<br />

1NO+1NC 230V 25A-250V 1 1 ES210<br />

110V 25A-250V 1 1 ES216<br />

24V 25A-250V 1 1 ES239<br />

ES230<br />

2NO 230V 25A-250V 1 12 ES220 ES220A<br />

40A-400V 3 1 ES240<br />

63A-400V 3 1 ES263<br />

110V 25A-250V 1 1 ES226<br />

24V 25A-250V 1 1 ES224 ES224A<br />

40A-400V 3 1 ES252<br />

63A-400V 3 1 ES262<br />

2NC 230V 25A-250V 1 12 ES230 ES230A<br />

110V 25A-250V 1 1 ES236<br />

3NO 230V 25A-400V 2 6 ES320 ES320A<br />

230V 40A-400V 3 1 ES340<br />

ES320<br />

3NO+1NC 230V 25A-400V 2 1 ES444<br />

40A-400V 3 1 ES345<br />

63A-400V 3 1 ES365<br />

4NO 230V 25A-400V 2 6 ES420 ES420A<br />

40A-400V 3 1 ES440<br />

63A-400V 3 1 ES463<br />

110V 25A-400V 2 1 ES426<br />

40A-400V 3 1 ES446<br />

63A-400V 3 1 ES466<br />

24V 25A-400V 2 1 ES424 ES424A<br />

40A-400V 3 1 ES442<br />

63A-400V 3 1 ES462<br />

ES463<br />

4NC 230V 25A-400V 2 6 ES430 ES430A<br />

40A-400V 3 1 ES480<br />

63A-400V 3 1 ES490<br />

110V 25A-400V 2 1 ES426<br />

40A-400V 3 1 ES436<br />

63A-400V 3 1 ES496<br />

24V 25A-400V 2 1 ES432<br />

63A-400V 3 1 ES492<br />

13<br />

14<br />

11<br />

12<br />

2NO+2NC 230V 25A-250V 2 1 ES450<br />

63A-250V 3 1 ES470<br />

24V 25A-250V 2 1 ES242<br />

13 11<br />

Auxiliary 2A-250V 1/2 1 EP071<br />

14<br />

12<br />

Heat dissipation insert 1/2 10 LZ060<br />

357


Low Noise Contactors<br />

Description<br />

For the remote switching and<br />

control of power circuits<br />

(20A-63A AC1)<br />

Technical data<br />

The choice of contactor<br />

depends<br />

upon a number of parameters,<br />

e.g.<br />

• The nature of the supply.<br />

• The power it is switching.<br />

• The characteristics of the load.<br />

• The control voltage required.<br />

• Number of operations<br />

All contactors ratings are for<br />

AC1<br />

loads only – if the load<br />

differs from AC1 the contactor<br />

may need de-rating.<br />

The use of LZ060 (heat<br />

dissipation inserts) between all<br />

contactors installed or<br />

between contactors and<br />

adjacent devices is<br />

recommended.<br />

Options<br />

Contact choice<br />

• Normally open (NO)<br />

• Normally closed (NC)<br />

Designation Type Coil Power Width in I Pack cat. ref<br />

AC voltage circuit AC1 17.5mm qty.<br />

2 NO 230V 50 Hz 25A - 250V 1 12 ESN220B<br />

40A - 400V~ 3 4 ESN240B<br />

63A - 400V~ 3 4 ESN263B<br />

3 NO 230V 50 Hz 25A - 400V 2 6 ESN320B<br />

ESN420B<br />

40A - 400V~ 3 4 ESN340B<br />

3 NO + 1 NC 230V 50 Hz 25A - 250V 2 6 ESN444B<br />

4 NO 230V 50 Hz 25A - 400V 2 6 ESN420B<br />

230V 50 Hz 40A - 400V~ 3 4 ESN440B<br />

230V 50 Hz 63A - 400V~ 3 4 ESN463B<br />

4 NC 230V 50 Hz 25A - 400V 2 6 ESN430B<br />

ESN440B<br />

Auxiliary Contact 1NO + 1NC 6 A - 250V 1/2 1 ESN071B<br />

Cover for 2 module contactors 2 10 ESN002B<br />

Cover for 3 module contactors 3 10 ESN003B<br />

358


Time switches and twilight switches selection chart<br />

Analogue time switches<br />

(din rail mounted) :<br />

Analogue time switches<br />

(72 x 72mm) :<br />

<strong>Modular</strong><br />

devices<br />

width in 1 ❚ :<br />

EH 010, EH 011<br />

width in 3 ❚ :<br />

EH 110, EH 111,<br />

EH 171<br />

width in 5 ❚ :<br />

EH 191<br />

EH 710, EH 711, EH 770<br />

EH 771, EH 712, EH 715<br />

EH 716<br />

Analogue time switches (din rail mounted)<br />

Analogue time switches (72 x 72mm)<br />

Technical<br />

characteristics EH 010 EH 011 EH 110 EH 111 EH 171 EH 191 EH 710 EH 711 EH 770 EH 771 EH 712 EH 715 EH 716<br />

Width in 1 1 3 3 3 5 - - - - - - -<br />

❚ 17.5mm<br />

Voltage 230V 230V 230V 230V 230V 230V 230V 230V 230V 230V 230V 48V DC<br />

supply<br />

110-240VAC<br />

Operating 24 hrs. 24 hrs. 24 hrs. 24 hrs. 7 days 24 hrs./ 24 hrs. 24 hrs. 7 days 7 days 24 hrs. 24 hrs. 24 hrs.<br />

cycle<br />

7 days<br />

Minimum 15 min 15 min 15 min 15 min 2 hrs. 15 min/ 20 min 20 min 2 hrs. 2 hrs. 20 min 20 min 20 min<br />

switching<br />

2 hrs.<br />

Supply failure - 200 hrs. - 200 hrs. 200 hrs. 200 hrs. - 200 hrs. - 200 hrs. - - 200 hrs.<br />

reserve<br />

Manual auto/ auto/ auto/ auto/ auto/ auto/ on/off on/off on/off on/off on/off on/off on/off<br />

override on on on/off on/off on/off on/off<br />

Digital time switches<br />

(din rail mounted) :<br />

Twilight switches<br />

(din rail mounted) :<br />

width in 1 ❚ :<br />

EG 010, EG 071<br />

width in 3 ❚ :<br />

EG 110, EG 170,<br />

EG 171,<br />

EG 210, EG 270<br />

width in 5 ❚ :<br />

EG 470<br />

EE 170<br />

Digital time switches (din rail mounted)<br />

Twilight switches<br />

Technical<br />

characteristics EG010 EG071 EG110 EG170 EG103B/E EG171 EG210 EG270 EG203B/E EG470 EE100 EE101 EE110 EE170 EE171<br />

Width in ❚17.5mm1 1 3 3 2 3 3 3 2 5 3 3 5 3 3<br />

Operating cycles 24hrs 7days 24hrs 7days 7 days 7days 24hrs 7days 7days 7days - - 24hrs 7days 7days<br />

Program steps 5 20 20 20 56 20 20 20 56 84 - - 15min 1min 1min<br />

Voltage supply 230V 230V 230V 230V 230V 230V 110/ 110/ 230V 230V 230V 230V 230V 230V 230V<br />

& DC 230V 230V<br />

N° of channels 1 1 1 1 1 1 2 2 2 4 - - 1 1 1<br />

(pulsed<br />

output)<br />

359


Analogue time switches modular<br />

Description<br />

Electromechanical time<br />

switches 1 channel for daily or<br />

weekly programming.<br />

To control lighting, heating,<br />

household appliances, shop<br />

windows etc...<br />

To improve comfort and save<br />

energy.<br />

Applications<br />

Domestic and commercial<br />

premises.<br />

DIN rail mounting<br />

Complies with EN60730<br />

Technical data<br />

- programming by captive<br />

segments.<br />

- manual override :<br />

On 1 module devices :<br />

- automatic<br />

- permanent ON<br />

On 3 and 5 module devices :<br />

- automatic<br />

- permanent ON<br />

- permanent OFF<br />

Minimum switching time:<br />

- 15 min for daily versions<br />

- 2 hours for weekly versions<br />

- 15 min and 2 hours on the<br />

daily+weekly version<br />

Connection capacity :<br />

1 to 4▫<br />

For technical details<br />

see page 396<br />

Designation Characteristics Width in I Pack Cat.<br />

17.5mm qty. ref.<br />

1 channel voltage supply : 230V<br />

daily dial<br />

50/60Hz<br />

without battery reserve output :<br />

1M devices = 1NO 1 1 EH010<br />

16A - 250V AC1<br />

3M devices = 1NO 3 1 EH110<br />

changeover<br />

16A - 250V AC1<br />

EH010<br />

1 channel voltage supply : 230V<br />

daily dial<br />

50/60Hz<br />

with battery reserve output :<br />

1M devices = 1NO 1 1 EH011<br />

16A - 250V AC1<br />

reserve : 3M devices = 1NO 3 1 EH111<br />

200 hours after being changeover<br />

connected for 120 hours<br />

16A - 250V AC1<br />

EH111<br />

1 channel voltage supply : 230V<br />

weekly dial<br />

50/60Hz<br />

with battery reserve output :<br />

1 changeover = 1NO 3 1 EH171<br />

reserve :<br />

16A - 250V AC1<br />

200 hours after being<br />

connected for 120 hours<br />

1 channel voltage supply : 230V<br />

daily + weekly dial<br />

50/60Hz<br />

with battery reserve output :<br />

1 changeover = 1NO 6 1 EH191<br />

reserve :<br />

16A - 250V AC1<br />

200 hours after being<br />

connected for 120 hours<br />

Sealable terminal cover kit<br />

for 3 modules time switches<br />

EH901<br />

Flush mounting kit for<br />

3 modules time switches<br />

EH902<br />

360


Analogue time switches 72 x 72 mm<br />

Description<br />

For daily or weekly<br />

programming.<br />

1 channel for the control of<br />

lighting, heating, household<br />

appliances, shop windows etc..<br />

To improve comfort and save<br />

energy.<br />

segments<br />

- manual override with automatic<br />

return to programme<br />

- operating reserve : 200 hours<br />

after being connected for 120<br />

hours<br />

- output : voltage free<br />

changeover contact 16A/250V<br />

Weekly version :<br />

Programming in steps of one<br />

hour.<br />

- minimum time between<br />

2 switching intervals : 2 hours<br />

- switching accuracy : 10 min<br />

<strong>Modular</strong><br />

devices<br />

Applications<br />

Domestic and commercial<br />

premises.<br />

Complies with EN60730<br />

Daily version :<br />

Programming in steps of<br />

10 minutes.<br />

Minimum time between<br />

2 switching intervals : 20 min<br />

Technical data<br />

- suitable for surface, flush or<br />

din rail mounting<br />

- programming by captive<br />

For technical details<br />

see page 396<br />

Designation Characteristics Pack Cat.<br />

qty.<br />

ref.<br />

1 channel daily cycle supply : 230V 50/60Hz<br />

without battery reserve 1 EH710<br />

with battery reserve 1 EH711<br />

economy version 1 EH712<br />

reserve : 200 hours after being<br />

connected for 120 hours<br />

1 channel weekly cycle supply : 230V 50/60Hz<br />

without battery reserve 1 EH770<br />

with battery reserve 1 EH771<br />

EH770<br />

reserve : 200 hours after being<br />

connected for 120 hours<br />

1 channel daily cycle supply : 48V<br />

110 to 240V 50/60Hz<br />

without battery reserve 1 EH715<br />

with battery reserve 1 EH716<br />

reserve : 200 hours after being<br />

connected for 120 hours<br />

Flush mounting kit<br />

EH900<br />

361


Digital time switches<br />

Description<br />

Use : domestic and commercial<br />

buildings<br />

For the control of lighting, heating,<br />

household appliances, shop<br />

windows, signage etc..., to<br />

improve comfort and to save<br />

energy.<br />

EG103B and EG203B<br />

(basic version)<br />

Product set at current time and<br />

date when delivered.<br />

Automatic change of summer /<br />

winter time.<br />

Programming key :<br />

- to allow easy back up and<br />

re-installation of the program to<br />

allow permanent program overrides.<br />

- programming per day or group<br />

of days<br />

- 56 ON/OFF programme steps<br />

- permanent ON/OFF overrides<br />

- temporary ON/OFF overrides<br />

- bar graph indication showing<br />

the daily profile<br />

- programming without the need<br />

to be energised.<br />

EG103E and EG203E<br />

(evolution version)<br />

Same characteristics as EG103B<br />

and EG203B plus more :<br />

- holidays mode : forcing ON or<br />

OFF between two dates<br />

- presence simulation - random<br />

switching<br />

- backlighted screen<br />

- impulse programming<br />

capability (1s to 30min)<br />

Operating voltage :<br />

230V~ 50/60Hz<br />

For technical details<br />

see page 398<br />

Designation Characteristics Width in I Pack Cat.<br />

17.5mm qty. ref.<br />

1 channel daily cycle 5 adjustable pre-recorded 1 1 EG010<br />

programs : 6 commutations<br />

per day (3 ON and 3 OFF)<br />

230V 50/60Hz<br />

capacity : 20 program steps 3 1 EG110<br />

230V 50/60Hz<br />

EG 071<br />

2 channels daily cycle capacity : 20 program steps to 3 1 EG210<br />

be divided between the<br />

2 channels<br />

110/230V 50/60Hz<br />

1 channel weekly cycle capacity : 20 program steps 1 1 EG071<br />

230V 50/60Hz<br />

capacity : 20 program steps 3 1 EG170<br />

230V 50/60Hz<br />

capacity : 56 program steps 2 1 EG103B<br />

output : 1 changeover contact<br />

µ 16A - 250V~ AC1<br />

EG 210<br />

EG 203E<br />

EG 400 / EG 002<br />

version delivered<br />

with key EG 005 2 1 EG103E<br />

1 channel weekly cycle capacity : 20 program steps 3 1 EG171<br />

pulsed output<br />

230V 50/60Hz<br />

pulsed output adjustable<br />

from 1 sec. to 99 mins.<br />

2 channels weekly cycle capacity : 20 program steps 3 1 EG270<br />

be divided between the 2 channels<br />

110/230v 50/60Hz<br />

capacity : 56 program steps 2 1 EG203B<br />

output : 2 changeover contacts<br />

µ 16A - 250V~ AC1<br />

version delivered<br />

with key EG 005 2 1 EG203E<br />

4 channels weekly cycle capacity : 84 program steps to 5 1 EG470<br />

be divided between the<br />

4 channels.<br />

230V 50/60Hz<br />

4 channels digital time switch capacity : 102 program steps 5 1 EG400<br />

weekly / annual cycle<br />

230V~ 50/60Hz<br />

output : 3 changeover contacts<br />

programm setting :<br />

10A - 250V~ AC1<br />

1 minute increments 1NO contact :<br />

10A - 250V ~ AC1<br />

lithium battery total of 10 years<br />

Programming key for EG 400 1 EG002<br />

Programming key for EG103 / EG 203 1 EG005<br />

Interface and software for computer PC via connection RS232 1 EG003<br />

with software on CD<br />

with USB 1 EG003U<br />

362


Astronomical time switches<br />

Description<br />

The hager range is composed of<br />

two Astronomical time switches<br />

EE180/EE181<br />

That range offers the following<br />

features :<br />

- Programming of the lighting<br />

interruption<br />

- Automatic change of<br />

winter / summer time<br />

- Astro program and expert<br />

program with individual Astro<br />

program steps<br />

- Programming for day or group<br />

of days (same concept than<br />

our existing clocks with key)<br />

- Anticipation ON<br />

- Maintained ON<br />

- Temporary overrides<br />

- Programming of holidays<br />

period<br />

- Programming via the PC<br />

software and the associated<br />

interface (EG003)<br />

- Weekly program<br />

For technical details<br />

see page 403<br />

<strong>Modular</strong><br />

devices<br />

Designation Characteristics Width in I Pack Cat.<br />

17.5mm qty. ref.<br />

Astronomical time switch 230V~ , 50Hz 2 1 EE180<br />

1 channel changeover contact<br />

(weekly cycle)<br />

16A AC1<br />

operating reserve<br />

lithium<br />

delivered with key EG005 battery 5 years<br />

EE180<br />

Astronomical time switch 230V~ , 50Hz 2 1 EE181<br />

2 channels 2 changeover contacts<br />

(weekly cycle)<br />

16A AC1<br />

operating reserve<br />

lithium<br />

delivered with key EG005 battery 5 years<br />

363


Twilight switches<br />

Description<br />

A photo-electric cell measures<br />

the light level and in conjuction<br />

with the relay provides ON / OFF<br />

control of a circuit.<br />

This device controls lighting circuits<br />

in relation to ambient light,<br />

based on user settings.<br />

Front cover sealability<br />

Applications<br />

Street lighting, display lighting,<br />

illuminated signes etc....<br />

Connection<br />

protected cable clamps<br />

capacity :<br />

rigid : 1.5 to 10mm 2<br />

flexible : 1 to 6mm 2<br />

on board LED shows status of<br />

changeover contact.<br />

Technical data<br />

4 position override switch allowing<br />

:<br />

- auto : normal operating mode<br />

- on : permanently switched on<br />

- off : permanently switched off<br />

- test : setting mode for easy<br />

adjustement<br />

output : 1 changeover AC1<br />

contact 16A AC1 230V<br />

8A AC1 (EE701)<br />

Maximum distance : 50m<br />

between photocell and controller<br />

Must be used in conjunction<br />

with a suitable rated contactor<br />

For technical details<br />

see page 403<br />

Designation Characteristics Width in I Pack Cat.<br />

17.5mm qty. ref.<br />

Twilight switch 3 1 EE100<br />

delivered with a separate<br />

surface photo electric cell (EE003)<br />

Twilight switch 3 1 EE101<br />

delivered with a separate<br />

flush photo eletric cell (EE002)<br />

EE110<br />

Programmable twilight daily cycle 5 1 EE110<br />

switch with surface cell<br />

electromech. switch<br />

Programmable twilight weekly cycle 3 1 EE170<br />

switch with surface cell<br />

electronical program<br />

8 presetted programs<br />

EE170<br />

Programmable twilight weekly cycle 3 1 EE171<br />

switch with surface cell<br />

electronical program<br />

free setting<br />

EE702<br />

Compact light switch 230V~ 50 Hz - 1 EE701<br />

basic 8A<br />

normally open contact<br />

(without settings)<br />

(cutting phase)<br />

8A AC1<br />

Fix lux : 10...30lux<br />

IP55 / Integrated cell<br />

Fix ON delay : 40s/OFF delay:120s 1000W incandescent<br />

Compact light switch 230V~ 50 Hz - 1 EE702<br />

enhanced 16A<br />

normally open contact<br />

(with settings)<br />

(cutting phase)<br />

16A AC1<br />

Fix lux : 2 to 1000 lux<br />

IP55 / Integrated cell<br />

Time settings : from 1s to 120s 2300W incandescent<br />

EE002<br />

Flush cell IP54 for EE100, 101, 110 & 170 1 EE002<br />

Surface cell IP54 for EE100, 101, 110 & 170 1 EE003<br />

EE003<br />

364


Comfortable energy saving …<br />

… with the presence detectors<br />

For the control or the regulation of lighting depending on<br />

presence and natural light<br />

The new <strong>Hager</strong> presence detectors with double lens<br />

technique are adapted to all architectural requirements.<br />

Whether for the regulation of the light depending on occupancy<br />

or simply to switch on the lights depending on presence<br />

and ambient luminosity, the <strong>Hager</strong> presence detectors<br />

offer the necessary flexibility for each application.<br />

Ventilation, ambient temperature or alarms can also be piloted<br />

exclusively by the detection of a movement thanks to the<br />

second channel. A pushbutton connected on the override entry<br />

makes it for example possible to cut the light or reduce it to<br />

the wished level during a presentation.<br />

<strong>Modular</strong><br />

devices<br />

An exciting technique<br />

The patented double lens technique<br />

ensures a very precise<br />

detection on 360° of a person<br />

moving on an area up to<br />

13 x 7 m. The integrated<br />

lux-meter makes it also possible<br />

to differentiate the proportion of<br />

natural and artificial light.<br />

Rotating and adaptable<br />

According to the architectural<br />

constraints, the detection zone<br />

can be adjusted with precision<br />

thanks to the rotation of lens on<br />

90°.<br />

Override<br />

The command entry on the 2<br />

channel presence detector<br />

(EE811) and on the presence<br />

regulator (EE812) allows the<br />

commutation of a lighting circuit<br />

(for example via a pushbutton).<br />

This facility is ideal for presentations<br />

during which the room must<br />

completely or partially darkened.<br />

When not more presence is detected<br />

the module will return to the<br />

automatic mode after the preselected<br />

time delay. Manual dimming<br />

is also possible via the same<br />

command entry on the presence<br />

regulator.<br />

Regulation with constant lighting<br />

: nearly a must in all<br />

open-plan offices. The presence<br />

regulator (EE812) adapts the<br />

artificial light depending on<br />

natural light and presence. The<br />

light intensity constantly remains<br />

fixed according to the preselected<br />

set point. An<br />

effective and pleasant lighting<br />

can be carried out easily and<br />

quickly with electronic regulators<br />

or the <strong>Hager</strong> 1000W dimmer.<br />

released after 15 minutes for<br />

the EE812 model.<br />

Master and slave : evolutionary<br />

for wide control<br />

The presence detectors can be<br />

connected between them for<br />

corridors or large premises. The<br />

Slave module will for example<br />

detect a presence, inform the<br />

Master module which then commands<br />

the light depending on<br />

luminosity, override and duration<br />

of lighting.<br />

Benefits :<br />

■ Models with 1 or 2 channels<br />

■ Regulators of presence /<br />

light<br />

■ Detection zone of 360°<br />

on 13 x 7 m<br />

■ Override entry or manual<br />

dimming<br />

■ Natural and artificial light<br />

measuring<br />

■ Wide setting possibilities<br />

■ Basic lighting mode on<br />

presence regulators EE812<br />

■ Master/Slave function<br />

Settings : lighting, time delay<br />

and manual dimming. Adjustable<br />

from 5 to 1200 Lux, the lighting/variation<br />

can also be setted<br />

manually via the command entry<br />

on the presence regulator. The<br />

time delay of the lighting and<br />

presence channel can be selected<br />

individually from 30 seconds<br />

to 1 hour.<br />

Basic lighting mode : for safety<br />

in hotels, homes, hospitals and<br />

corridors. The detector will<br />

switch on the lighting channel in<br />

case of presence. The time delay<br />

begins once no more presence<br />

is detected. The light will then be<br />

reduced to the selected value<br />

between 0 and 50%, then<br />

comprehensive<br />

settings<br />

rectangular capture<br />

zone<br />

natural and artificial<br />

light measure<br />

rotating front<br />

lens<br />

365


Conventional presence detectors<br />

Description<br />

EE810, EE811 and EE812<br />

High performance presence<br />

detector that will be used in<br />

premises or in passage areas,<br />

where they increase comfort and<br />

reduce drastically the energy<br />

costs.<br />

Combination of a presence<br />

area and a motion area. The<br />

presence area is especially interesting<br />

in offices, where the<br />

motion area may be used in long<br />

corridors.<br />

Head rotation for detection area<br />

adjustment<br />

Settings via potentiometers<br />

Applications<br />

EE810 - 1 channel detector<br />

Direct control of a light load or<br />

used as a slave for detection<br />

area enlargement.<br />

Lux level and ON delay setting<br />

via potentiometers<br />

Test mode in order to set lux<br />

level and the detection pattern<br />

EE811 - 2 channels detector<br />

Light relay output for direct<br />

control of a light load<br />

Presence output potential free<br />

relay.<br />

Lux level, on delay setting for<br />

light channel and presence<br />

channel via potentiometers<br />

Input for slave (EE810) and/or<br />

derogation push button.<br />

EE812 - Light regulator 1/10V<br />

Light regulator with 1/10V output<br />

in order to control electronic ballasts<br />

and/or <strong>Hager</strong> dimmers<br />

EV100/EV102. Detector especially<br />

dedicated for energy saving<br />

and comfort purpose.<br />

Input for slave (EE810) and/or<br />

derogation pushbutton in order<br />

to modify the setpoints<br />

Lux level, On delay for light<br />

channel and min level via potentiometers<br />

3 functional modes :<br />

no regulation, regulation with<br />

local setpoint, regulation with<br />

remote setpoint<br />

EE813 : accessory to surface<br />

mounting<br />

For technical details<br />

see page 405<br />

Designation Characteristics Width in I Pack Cat.<br />

17.5mm qty. ref.<br />

Presence detector<br />

230V~ 50Hz<br />

1 channel µ16A AC1 - 1 EE810<br />

• relay output light channel<br />

- lux level and on delay triac output 0.8A<br />

(duration or pulse) defined via<br />

potentiometers<br />

• Slave output for association<br />

with EE811/EE812<br />

Lux OFF<br />

EE810<br />

Presence detector<br />

230V~ 50Hz<br />

2 channels µ16A AC1 - 1 EE811<br />

• Relay output light channel<br />

- lux level and On delay 230V input 50Hz<br />

define via potentiometers<br />

- input slave / derogation<br />

- 230V input used with pushbutton<br />

to toggle the light channel<br />

state or with slave in order to<br />

enlarge the detection area<br />

• Relay output presence channel<br />

- on delay presence defined via<br />

potentiometer<br />

µ2 A AC1<br />

EE812<br />

EE813<br />

Presence detector 1/10V 230V~ 50Hz - 1 EE812<br />

• Relay output used to switch µ10 A AC1<br />

ON/OFF the electronic ballast<br />

• 1/10V output used to control an 1/10V 50mA<br />

electronic ballast or <strong>Hager</strong><br />

dimmers EV100/EV102<br />

• 230V input used with push- 230V input 50Hz<br />

button to toggle the channel<br />

or change the setpoint or with<br />

slave in order to enlarge the<br />

detection area<br />

• 3 functional modes defined via<br />

potentiometers<br />

mode 1 : no regulation<br />

mode 2 : regulation with local setpoint<br />

via potentiometer<br />

mode 3 : regulation with setpoint<br />

defined via a remote push button<br />

Accessory - 1 EE813<br />

mounting accessory for surface mounting<br />

can be used with EE810, EE811, EE812<br />

366


Delay timers<br />

58<br />

44<br />

45<br />

Description<br />

To provide all types of<br />

automatic control i.e. lighting,<br />

ventilation, watering, machine<br />

pre-heating, automatic door and<br />

visual audible indication, cycle<br />

control etc.<br />

Applications<br />

For timing and automation in<br />

domestic and commercial<br />

premises. The input signal can<br />

be via various switching devices<br />

(pushbutton, latching switch,<br />

timeclock etc.) and the timed<br />

output used to control the<br />

application.<br />

Technical data<br />

Voltage range :<br />

12 & 24 to 48V DC<br />

12 & 24 to 230V AC<br />

Adjustable: time delay from 0.1s<br />

to 10 hours.<br />

LED indicator<br />

complies with EN 60669-2-1<br />

Connection capacity :<br />

6mm 2 max flexible<br />

1.5 - 10mm 2 rigid<br />

For technical details<br />

see pages 409<br />

<strong>Modular</strong><br />

devices<br />

Designation Characteristics Width in I Pack Cat.<br />

17.5mm qty. ref.<br />

Delay ON 1 c/o contact 1 1 EZ001<br />

10A / 230V~ AC1<br />

Eingang<br />

time delay T : 0.1s to 10hr<br />

Ausgang<br />

T<br />

EZ001<br />

1 Delay OFF 1 c/o contact 1 1 EZ002<br />

10A / 230V~ AC1<br />

Eingang<br />

time delay T : 0.1s to 10hr<br />

Ausgang<br />

T<br />

Adjustable time ON 1 c/o contact 1 1 EZ003<br />

10A / 230V~ AC1<br />

Eingang<br />

time delay T : 0.1s to 10hr<br />

Ausgang<br />

T<br />

EZ003<br />

Timer 1 c/o contact 1 1 EZ004<br />

10A / 230V~ AC1<br />

Eingang<br />

time delay T : 0.1s to 10hr<br />

Ausgang<br />

T<br />

Symmetrical flasher 1 c/o contact 1 1 EZ005<br />

10A / 230V~ AC1<br />

Eingang<br />

time delay T : 0.1s to 10hr<br />

Ausgang<br />

T<br />

EZ006<br />

Multifunction 1 c/o contact 1 1 EZ006<br />

6 individual functions 10A / 230V~ AC1<br />

including :<br />

time delay T : 0.1s to 10hr<br />

D - delay on<br />

C - delay off<br />

E - adjustable time ON<br />

B - adjustalbe time OFF<br />

A - timer<br />

F - symmetrical flasher<br />

- ON<br />

- OFF<br />

367


Time lag switches<br />

Description<br />

EMN001 and EMN005 time lag<br />

switches to provide control of<br />

lighting circuits with automatic<br />

switch-off after a pre-set time.<br />

(e.g. for staircase, corridors<br />

lighting).<br />

The units are of compact with a<br />

2 position switch for permanent/<br />

timed lighting implementation<br />

facility.<br />

1 EMN 005 and EMS 005 incorporate<br />

a pre-warning of switch<br />

OFF to improve the safety for<br />

users and a double delay function<br />

: 30 sec. to 10 min. or 1<br />

hour by pressing the push- button<br />

more than 3s<br />

For technical details<br />

see pages 411<br />

Description Characteristics Width in I Pack Cat.<br />

17.5mm qty. ref.<br />

EMN001<br />

Basic staircase time lag switch voltage rating : 230V 50/60Hz 1 6 EMN001<br />

adjustable time delay setting:<br />

30 seconds until 10 minutes<br />

retrigger<br />

16A - 230V AC1<br />

2300 W incandescent<br />

1500 W halogen VLV<br />

10A - 1000 W compact fluorescent<br />

1000 W Fluo mono/duo<br />

460 W Fluo compact<br />

Multifunction stair case voltage rating : 230V 50/60Hz 2 1 EMN005<br />

time lag switch<br />

- basic stair case time lag switch<br />

- pre-warning mode<br />

- double delay mode<br />

30 sec. to 10 min. or 1 hr.<br />

- double delay with pre-warning mode<br />

16A - 230V AC1<br />

2300 W incandescent<br />

1500 W halogen VLV<br />

1000 W Fluo mono/duo<br />

460 W Fluo compact<br />

368


Emergency lighting module<br />

Application :<br />

for residential and commercial<br />

premises.<br />

Installed in a consumer unit or<br />

distribution board, the lamp can<br />

be configured to light<br />

automatically in the event of<br />

power failure.<br />

It can also be withdrawn from its<br />

base, thereby acting as a mini<br />

torch with an operating duration<br />

of 1 hour 30min.<br />

For technical information<br />

see page 412<br />

Designation Width in I Pack Cat.<br />

17.5mm qty. ref.<br />

<strong>Modular</strong><br />

devices<br />

Emergency lighting module 3 1 EE960<br />

EE960<br />

Remote control for emergency light blocks<br />

The remote control device<br />

switches self contained emergency<br />

lighting into neutral position<br />

or into working position.<br />

It permits each day after closing<br />

down of premises, to switch off<br />

self contained emergency lighting<br />

to avoid the discharge of<br />

battery.<br />

The remote control is<br />

recommended in premises for<br />

public and in industrial or<br />

commercial premises.<br />

The device is a 2 position changeover<br />

switch, with automatic<br />

recall for switching off or on, of<br />

self contained emergency lighting,<br />

by delivering polarized current<br />

impulses on the remote<br />

control circuits (+ or -)<br />

Connection capacity :<br />

6 flexible wire<br />

10 rigid wire<br />

For technical information<br />

see page 412<br />

Designation Characteristics Width in I Pack Cat.<br />

17.5mm qty. ref.<br />

Remote control<br />

to control up to 60 self<br />

contained,<br />

with an average consumption of<br />

0,1 mA / 6 V<br />

power supply :<br />

230 V 50/60 Hz<br />

output supply : 8,4 V ...<br />

time delay for power supply :<br />

24 hours before activation of<br />

remote control<br />

4 1<br />

EE905<br />

Remote control<br />

to control up to 120 self<br />

contained,<br />

with an average consumption of<br />

0,1 mA / 6 V<br />

power supply :<br />

230 V 50/60 Hz<br />

output supply : 12 V ...<br />

time delay for power supply :<br />

24 hours before activation of<br />

remote control<br />

4 1 EE910<br />

EE910<br />

369


Dimmers<br />

range overview<br />

functioning as a standalone product<br />

0W 20W 60W 100W 300W 600W 1000W<br />

functioning in system : association of dimmers<br />

with 1/10V max 30 x 1kW<br />

Incandescent/halogen 230V<br />

EV 011, EV 012<br />

EV 002, EV 004<br />

EV 100, EV 102 switch to “local” position<br />

EV 102 pilot : switch to “master” position<br />

EV 102 + n x EV 100 or EV 102 (slave position)<br />

Halogen VLV (12 or 24V) ferromagnetic<br />

transformer suitable<br />

for dimming.<br />

The transformer shouldn’t be used<br />

with less than 75% of nominal load<br />

Halogen VLV (12 or 24V) via electronic<br />

transformer<br />

EV 011<br />

EV 002, EV 004<br />

EV 100, EV 102 switch to “local” position<br />

EV 012<br />

EV 002, EV 004<br />

EV 100, EV 102 switch to “local” position<br />

EV 102 pilot : switch to “master” position<br />

EV 102 + n x EV 100 or EV 102 (slave position)<br />

EV 102 pilot : switch to “master” position<br />

EV 102 + n x EV 100 or EV 102 (slave position)<br />

1/10V control (output only)<br />

fluo with electroballast 1/10V<br />

Input 1/10 V, 50 mA<br />

EV 106<br />

EV 108 with scene inputs<br />

300 W 600 W 1000 W Pilot 1/10 V<br />

Technical features<br />

EV 011<br />

EV 012<br />

EV 002<br />

EV 004<br />

EV 100 EV 102 EV 106 EV 108<br />

Controls available<br />

- on the product<br />

- external with illuminated pushbutton<br />

- input 1/10 V<br />

- ambient lighting setting<br />

-<br />

yes<br />

-<br />

-<br />

yes<br />

yes<br />

-<br />

1 (EV 004)<br />

yes<br />

yes<br />

yes (slave)<br />

-<br />

yes<br />

yes<br />

yes (slave)<br />

2 levels<br />

yes<br />

yes<br />

-<br />

-<br />

yes<br />

yes<br />

-<br />

2 levels<br />

Types of outputs :<br />

- direct (capacitive/inductive load)<br />

- input 1/10 V<br />

yes<br />

-<br />

yes<br />

-<br />

yes<br />

-<br />

yes<br />

yes (master)<br />

-<br />

yes<br />

-<br />

yes<br />

Functions :<br />

- protection overheating / overloads<br />

- level indicator<br />

- memorisation<br />

- softstart<br />

yes *<br />

-<br />

yes<br />

yes<br />

yes<br />

EV 004<br />

yes<br />

yes<br />

yes<br />

-<br />

yes<br />

yes<br />

yes<br />

yes<br />

yes<br />

yes<br />

yes<br />

yes<br />

yes<br />

-<br />

yes<br />

yes<br />

yes<br />

-<br />

Parameter setting :<br />

- mini, max. level<br />

- dimming speed<br />

- speed at start / stop<br />

- transition speed for level call<br />

-<br />

-<br />

-<br />

-<br />

EV 004<br />

EV 004<br />

EV 004<br />

-<br />

yes<br />

-<br />

-<br />

-<br />

yes<br />

yes<br />

yes<br />

yes<br />

yes<br />

yes<br />

yes<br />

yes<br />

yes<br />

yes<br />

yes<br />

yes<br />

* EV 011 : protection via integrated fuse, electronic protection for other products<br />

dimmers 300 W<br />

universal dimmers 600 W<br />

system dimmers<br />

universal dimmers 1000 W<br />

system dimmers<br />

1-10 V pilots<br />

EV 011 EV 012<br />

EV 002 EV 004<br />

EV 100 EV 102<br />

EV 106 EV 108<br />

370


Dimmers<br />

The <strong>Hager</strong> products are suitable<br />

for all light sources : incandescent,<br />

LV and VLV halogen, fluorescent<br />

with electronic ballast.<br />

Dimming controlled by<br />

push button :<br />

- start/stop by short press<br />

- increasing/decreasing by maintaining<br />

pressure<br />

Common characteristics :<br />

- Softstart (progressive start) to<br />

increase the working live of<br />

lamps<br />

- memorisation of last dimming<br />

level<br />

- protection against overheating<br />

- control possible by illuminated<br />

pushbutton until 5mA.<br />

Dimmer<br />

300 W :<br />

- control by several pushbuttons<br />

- can replace a latching relay<br />

with dimming function<br />

Dimmers 600 and 1000 W :<br />

- universal products with<br />

automatic recognition of the<br />

load<br />

type (inductive/capacitive)<br />

- electronic protection against<br />

overheating and overload<br />

- Indicators :<br />

230 V / overheating / overload<br />

For technical details<br />

see page 413<br />

<strong>Modular</strong><br />

devices<br />

Designation Characteristics Width in ❚ Pack Ref.<br />

17,5 mm qty<br />

Dimmers 300 W<br />

for :<br />

- incandescent 230 V<br />

- halogen 230 V<br />

- VLV halogen lamps with :<br />

• ferromagnetic transformer<br />

(inductive load EV 011 )<br />

• dimmable electronic transformer<br />

(capacitive load (EV 012 )<br />

20 ... 300 W / VA<br />

230 V / 50 Hz<br />

inductive load<br />

capacitive load<br />

1<br />

1<br />

1<br />

1<br />

EV011<br />

EV012<br />

EV011<br />

Universal remote control dimmer<br />

600 W<br />

for :<br />

- incandescent 230 V<br />

- halogen 230 V<br />

- VLV halogen lamps supplied by<br />

ferromagnetic or dimmable electronic<br />

transformer<br />

(cos ≥ 0,95)<br />

20 ... 600 W / VA<br />

230 V / 50 Hz<br />

- products with automatic load<br />

recognition<br />

- dimming function<br />

4 1<br />

EV002<br />

Enhanced universal dimmer<br />

600 W<br />

in addition to EV 002 features :<br />

- min/max level setting<br />

- recall mode with pushbutton,<br />

override mode with switch<br />

- scene level setting<br />

0 ... 99 %<br />

4 1<br />

EV004<br />

EV004<br />

371


Dimmers<br />

For technical details see<br />

pages 413-415<br />

Designation Characteristics Width in ❚ Pack Ref.<br />

17.5 mm qty<br />

EV100<br />

Universal dimmer 1000 W for :<br />

• Functional mode selection via<br />

local switch :<br />

- control via pushbutton (local)<br />

- remote control via 1/10V (slave)<br />

• Min/Max setting via potentiometer<br />

• LED indication :<br />

- 230V power supply/load error<br />

- overload / overheating<br />

Load type :<br />

- incandescent<br />

- 230V halogen lamps<br />

- VLV halogen lamps associated<br />

to ferromagnetic transformer<br />

(inductive)<br />

- VLV halogen lamps associated<br />

to electronic transformer (capacitive)<br />

230 V / 50 Hz<br />

20 ...1 000W<br />

1/10V-input<br />

5 1<br />

EV100<br />

EV102<br />

Universal dimmer 1000 W with<br />

scene inputs<br />

• Functional mode selection via<br />

local switch :<br />

- control via pushbutton (local)<br />

- remote control via 1/10V (slave)<br />

- control of the other dimmers via<br />

1/10V (master)<br />

• Display to show the dim level<br />

and to set the parameters:<br />

- dimming rise time (4s ..99s)<br />

- min dim level (0...49%)<br />

- max dim level (51..99%)<br />

- rise time when switching ON<br />

(1s..99s)<br />

- fall time when switching OFF<br />

(1s..99s)<br />

- scene level<br />

- dimming rise time for each scene<br />

- scene working mode :<br />

recall or override mode<br />

• Output contact to display the<br />

dim state (load is OFF, contact is<br />

opened, if load is dimmed the<br />

contact is closed)<br />

• LED indication :<br />

- 230V power supply / load error<br />

- overload / overheating<br />

Load type :<br />

- incandescent<br />

- 230V halogen lamps<br />

- VLV halogen lamps associated to<br />

ferromagnetic transformer (inductive)<br />

- VLV halogen lamps associated to<br />

electronic transformer (capacitive)<br />

230 V / 50 Hz<br />

20 ...1 000W<br />

1/10V-input/output<br />

(max. 50mA, 30 EV100 / EV102)<br />

defined via the local switch<br />

Contact output :<br />

1 NO, 250V , µ 5A<br />

5 1 EV102<br />

372


Dimmer system: 1/10V pilots<br />

EV 106 and EV 108 pilot<br />

dimmers<br />

• To control several dimmers or<br />

electronic ballasts via the 1/10V<br />

output<br />

• Display to show the dim level<br />

and for parameter setting<br />

• Wiring of illuminated<br />

pushbuttons possible up to<br />

5mA<br />

• Min/max level setting<br />

• Contact output for state<br />

information<br />

• Dimming rise time setting<br />

• Setting of rise time and fall<br />

time<br />

EV 108 pilot dimmer<br />

• Scene inputs used for override<br />

(3 levels) or simple recall<br />

(2 levels).<br />

Use :<br />

to control lighting in meeting and<br />

conference rooms, or in restaurants<br />

Dimmers conform to standards :<br />

EN 50081-1, EN 50082-1,<br />

CEI 669-1, CEI 669-2-1.<br />

For technical details<br />

see page 413<br />

Designation<br />

Characteristics<br />

Width in ❚<br />

17.5 mm<br />

Pack<br />

qty<br />

Ref<br />

<strong>Modular</strong><br />

devices<br />

1/10V pilot dimmer<br />

230 V / 50 Hz<br />

4 1<br />

EV106<br />

EV106<br />

• To control<br />

EV 100 and EV 102 (max. 30)<br />

• To dim electronic ballasts<br />

• Wiring of illuminated<br />

pushbuttons possible up to<br />

5mA<br />

• Display to show the dim level<br />

and to set the parameters:<br />

- dimming rise time (4 s ..99s)<br />

- min dim level (0..49%)<br />

- max. dim level (51..99%)<br />

Contact output to display the<br />

dim state (load is OFF, contact is<br />

opened, if load is dimmed the<br />

contact is closed). It is used to<br />

switch ON/OFF the electronic<br />

ballast<br />

1/10V - interface<br />

Output /max 50mA<br />

contact output :<br />

1 NO, 250 V µ10 A<br />

1/10V pilot dimmer with scene<br />

input<br />

4 1<br />

EV108<br />

EV108<br />

In addition to EV106 features :<br />

• Scene inputs used for override<br />

(3 levels) or simple recall (2)<br />

• For each scene<br />

- dimming rise time<br />

- scene level<br />

- and scene mode<br />

(recall or- override)<br />

373


Switch disconnectors<br />

44<br />

68<br />

45<br />

Description<br />

For use a switch as a<br />

disconnector in all types of<br />

circuit.<br />

Complies with : EN 60 947-3 all<br />

ratings<br />

Technical data<br />

utilisation category<br />

AC 22B<br />

In : 16, 25, 32A<br />

shrouded cable clamps<br />

connection capacity:<br />

16mm 2 rigid conductor<br />

10mm 2 flexible conductor<br />

In : 40, 63, (1 pole)<br />

cable clamps,<br />

connection capacity:<br />

25mm 2 rigid conductor<br />

16mm 2 flexible conductor<br />

In : 80A, 100A<br />

cable clamps<br />

connection capacity:<br />

50mm 2 rigid conductor<br />

35mm 2 flexible conductor<br />

All switches have a green / red<br />

indication on the handle giving<br />

positive contact indication<br />

use MZN175 as locking device<br />

Designation Characteristics Width in I Pack Cat.<br />

17.5mm qty. ref.<br />

SB140<br />

Single pole 1 x 16A 250V~ 1 12 SB116<br />

1 x 16A 250V~ 1 1 SB116V<br />

with pilot light<br />

1 x 25A 250V~ 1 12 SB125<br />

1 x 25A 250V~ 1 1 SB125V<br />

with pilot light<br />

1 x 32A 250V~ 1 1 SB132<br />

1 x 32A 250V~ 1 1 SB132V<br />

with pilot light<br />

1 x 40A 250V~ 1 1 SB140<br />

1 x 63A 250V~ 1 1 SB163<br />

1 x 80A 250V~ 1 1 SB180<br />

1 x 100A 250V~ 1 1 SB199<br />

SB232<br />

SB240<br />

Double pole 2 x 16A 250V~ 1 12 SB216<br />

2 x 16A 250V~ 1 1 SB216V<br />

with pilot light<br />

2 x 25A 250V~ 1 12 SB225<br />

2 x 25A 250V~ 1 1 SB225V<br />

with pilot light<br />

2 x 32A 250V~ 1 1 SB232<br />

2 x 32A 250V~ 1 1 SB232V<br />

with pilot light<br />

2 x 40A 250V~ 1 1 SB240<br />

2 x 63A 250V~ 1 6 SB263<br />

2 x 80A 250V~ 1 1 SB280<br />

2 x 100A 250V~ 1 1 SB299<br />

Triple pole 3 x 16A 400V~ 2 1 SB316<br />

3 x 25A 400V~ 2 1 SB325<br />

3 x 32A 400V~ 2 1 SB332<br />

3 x 32A 400V~ 3 1 SB332Q<br />

large terminals<br />

3 x 40A 400V~ 3 1 SB340<br />

3 x 63A 400V~ 3 1 SB363<br />

3 x 80A 400V~ 3 1 SB380<br />

3 x 100A 400V~ 3 1 SB399<br />

SB363<br />

Designation Characteristics Width in I Pack Cat. ref. Cat. ref.<br />

17.5mm qty. neutral neutral<br />

left<br />

right<br />

Four pole<br />

4 x 16A 400V~ 2 1 SB416F SB416<br />

4 x 25A 400V~ 2 1 SB425F SB425<br />

4 x 32A 400V~ 2 1 SB432F SB432<br />

4 x 40A 400V~ 4 1 SB440F SB440<br />

4 x 63A 400V~ 4 1 SB463F SB463<br />

4 x 80A 400V~ 4 1 SB480F SB480<br />

4 x 100A 400V~ 4 1 SB499F SB499<br />

374


Trip free switches<br />

Type SA<br />

Free tripping disconnector<br />

switch<br />

Allows remote control* tripping<br />

via voltmetric tripping relay to<br />

associate on the left side of<br />

product<br />

associated auxiliary : auxiliary<br />

contact (AC).<br />

For the main protection in<br />

general or sub-switchboard<br />

* emergency stop<br />

Connection capacity for switch :<br />

- 6 to 16 flexible<br />

- 6 to 25 rigid<br />

associated auxiliary :<br />

- 0,5 to 6 flexible<br />

- 1 to 10 rigid<br />

Complies with :<br />

IEC 947-1 and 947-3<br />

AC 23 A<br />

For technical details<br />

see page 420<br />

Designation Characteristics Width in ❚<br />

17,5 mm<br />

Pack<br />

qty<br />

Ref.<br />

2 pole switches 2 x 40 A 250 V <br />

2,5<br />

2 x 63 A 250 V <br />

2,5<br />

1<br />

1<br />

SA240<br />

SA263<br />

<strong>Modular</strong><br />

devices<br />

Ui = 690 V<br />

2 x 80 A 250 V <br />

2,5<br />

1<br />

SA280<br />

4 pole switches 4 x 40 A 400 V <br />

4,5<br />

1<br />

SA440<br />

SA263<br />

4 x 63 A 400 V <br />

4,5<br />

1<br />

SA463<br />

Ui = 690 V<br />

4 x 80 A 400 V <br />

4,5<br />

1<br />

SA480<br />

Shunt trip<br />

allows remote tripping<br />

of the trip free switch.<br />

230 - 415V~ 1 1 MZ203<br />

110 - 130V=<br />

24 - 48V~ 1 1 MZ204<br />

12 - 48V=<br />

MZ203<br />

Under voltage release<br />

allows trip free switch to be<br />

closed only when voltage is<br />

above 70% of Un. trip free<br />

switch will automatically trip<br />

when voltage falls by 35% of Un<br />

48V = 1 1 MZ205<br />

230V ~ 1 1 MZ206<br />

MZ206<br />

375


2 way / centre - off changeover modular switches<br />

Designation Characteristics Width in I Pack Cat.<br />

17.5mm qty. ref.<br />

Switch, 2 ways<br />

single pole<br />

1 x 25A 250V~ 1 12 SF118F<br />

1<br />

2 4<br />

Double pole<br />

2 x 25A 250V~ 1 12 SF115<br />

1<br />

3<br />

SF118F<br />

2 4<br />

Double pole<br />

2 x 25A 250V~ 2 6 SF218F<br />

1<br />

5<br />

2 4<br />

6 8<br />

SF219F<br />

Switches<br />

centre - off changeover<br />

single pole<br />

1<br />

1 x 25A 250V~ 1 12 SF119F<br />

1 x 40A 250V~ 1 12 SF119G<br />

2 4<br />

double pole<br />

1<br />

5<br />

2 4 6 8<br />

2 x 25A 250V~ 2 6 SF219F<br />

2 x 40A 250V~ 2 6 SF219G<br />

3 x 40A 250V~ 3 4 SF319G<br />

4 x 40A 250V~ 4 3 SF419G<br />

SZ010<br />

Handle link pin<br />

for switch handles<br />

1 set includes 1 set SZ010<br />

5 pins 2 mod width<br />

5 pins 3 mod width<br />

5 pins 4 mod width<br />

376


Pushbuttons<br />

Description<br />

To actuate loads either directly<br />

or via contactors etc.<br />

Technical data<br />

<strong>Modular</strong> pushbuttons :<br />

- without light<br />

with grey button, red/green<br />

optional<br />

- with light<br />

with red, green button (amber,<br />

blue, colourless, red, green lenses<br />

on option).<br />

delivered with lamp 230V~, E10<br />

cap.<br />

Options<br />

Pushbuttons can be fitted with<br />

12, 24, 48, 60V lamps (see<br />

below).<br />

Connection capacity :<br />

Shrouded cable clamp type<br />

10▫ rigid conductor<br />

6▫ flexible conductor<br />

<strong>Modular</strong><br />

devices<br />

Designation Characteristics Width in I Pack Cat.<br />

17.5mm qty. ref.<br />

Pushbuttons<br />

without indicator light<br />

impulse 16A - 250V~<br />

contact : 1NO 1 12 SV021<br />

contacts : 2NO 1 12 SV022<br />

contacts : 3NO 1 12 SV025<br />

SV025<br />

contact : 1NC 1 12 SV023<br />

contacts : 2NC 1 12 SV024<br />

contacts : 1NO / 1NC 1 12 SV120<br />

contacts : 1NO+1NC 1 12 SV031<br />

contacts : 2 changeovers 1 12 SV026<br />

SV031<br />

Pushbuttons<br />

impulse<br />

with indicator light<br />

contact: 1NO green 1 12 SV124<br />

contacts: 2 NO red 1 12 SV062<br />

contact: 1 NC red 1 12 SV123<br />

contacts: 2 NC green 1 12 SV064<br />

SV062<br />

377


Pushbuttons (Latching)<br />

Designation Characteristics Width in I Pack Cat.<br />

17.5mm qty. ref.<br />

Pushbuttons<br />

without indicator light<br />

latching 16A - 250V~<br />

contact : 1NO 1 12 SV041<br />

contacts : 2NO 1 12 SV042<br />

contacts : 3NO 1 12 SV047<br />

contacts : 4NO 1 12 SV048<br />

contacts : 1NO+1NC 1 12 SV045<br />

contacts : 2 changeovers 1 12 SV046<br />

Pushbuttons<br />

latching<br />

with indicator light<br />

contact : 1NO green 1 12 SV071<br />

contacts : 2NO green 1 12 SV072<br />

SV072<br />

Indicator lights<br />

38<br />

62<br />

Description<br />

<strong>Modular</strong> indicator lights<br />

Available with red, green,<br />

amber, blue, colourless lens<br />

Delivered with lamp 230V~,<br />

E10 cap.<br />

Options<br />

Indicator lights can be fitted with<br />

12, 24, 48, 60V lamps (see<br />

below).<br />

shrouded cable clamp type<br />

Connection capacity:<br />

10▫ rigid conductor.<br />

6▫ flexible conductor.<br />

45<br />

Designation Characteristics Width in I Pack Cat.<br />

17.5mm qty. ref.<br />

Indicator green lens 1 12 SVN121<br />

lights<br />

with light 230V~ red lens 1 12 SVN122<br />

230 V~<br />

orange lens 1 12 SVN123<br />

clear lens 1 12 SVN124<br />

blue lens 1 12 SVN125<br />

red & green double indicator 1 12 SVN126<br />

red triple indicator 1 12 SVN127<br />

378


Auxiliaries for pushbuttons and indicator lights ...<br />

38<br />

67<br />

45<br />

Description<br />

This system makes it possible to<br />

build a large range of<br />

pushbuttons and indicator<br />

lamps.<br />

Pushbuttons are built using :<br />

- a base<br />

- the contents<br />

- the lamps<br />

A choice of 6 auxiliary contacts<br />

are available.<br />

The lamp can be selected as<br />

needed.<br />

Indicator lamps :<br />

- the base<br />

- a choice of 5<br />

colours<br />

- 12-230V<br />

Auxiliaries with flashing or test<br />

lamp facility.<br />

Characteristics :<br />

pushbuttons<br />

- 16A AC21 230V~<br />

lamps<br />

12, 24, 48, 60V~ - 0.9W<br />

230V~ neon 0.5W<br />

230V~ fluorescent 0.6W<br />

use fluorescent lamp with blue<br />

and green lenses.<br />

Connection capacity:<br />

10▫ rigid conductor.<br />

6▫ flexible conductor.<br />

<strong>Modular</strong><br />

devices<br />

Designation Characteristics Width in I Pack Cat.<br />

17.5mm qty. ref.<br />

Supports<br />

for single pushbutton (impulse) 1 6 SW020<br />

(latching) 1 6 SW040<br />

SW020<br />

SW030<br />

for double pushbutton 1 6 SW030<br />

1 6 SW050<br />

+<br />

1 6 SW090<br />

for single pushbutton 1 6 SW060<br />

and indicator<br />

1 6 SW070<br />

for indicator lights 1 6 SW080<br />

SW070<br />

SW080<br />

Electrical auxiliaries 16A - 250V~<br />

for pushbuttons<br />

contact : 1NO 12 SW007<br />

contacts : 2NO 12 SW002<br />

SW007<br />

SW002<br />

contact : 1NC 12 SW003<br />

contacts : 2NC 12 SW004<br />

contact : 1 changeover 12 SW006<br />

contacts : 1NO+1NC 12 SW005<br />

SW003<br />

SW005<br />

379


Auxiliaries for pushbuttons and indicator lights<br />

Designation Characteristics Pack Cat.<br />

qty.<br />

ref.<br />

Electrical auxiliaries<br />

for indicator lights<br />

test lamp to test a serie of indicator lights 6 SW112<br />

on the same phase<br />

for signal application for one or several indicator lights 6 SW113<br />

SW112<br />

SW113<br />

End plate 12 SW009<br />

for pushbuttons<br />

SW009<br />

SW081 SW082 SW083<br />

Lenses green 12 SW081<br />

for pushbuttons and<br />

indicator lights red 12 SW082<br />

SW084<br />

SW085<br />

orange 12 SW083<br />

clear 12 SW084<br />

blue 12 SW085<br />

SW104<br />

Lamps E10 neon 230V~ 0.5W 20 SW104<br />

for pushbuttons and<br />

indicator lights fluorescent 230V~ 0.6W 20 SW103<br />

incandescent 12V~ 0.9W 20 SW105<br />

24V~ 0.9W 20 SW102<br />

48 & 60V~ 0.9W 20 SW107<br />

SW015 SW016 SW019<br />

Interchangeable (impulse) grey 12 SW017<br />

pushbuttons covers<br />

(latching) grey 12 SW018<br />

SW017<br />

SW018<br />

green 12 SW015<br />

red 12 SW016<br />

clear 12 SW019<br />

380


Transformers, bells and buzzers<br />

58<br />

44<br />

45<br />

Description<br />

Provide extra safety low voltage<br />

8, 12, 24V~.<br />

Technical data<br />

Secondary voltages:<br />

8, 12, 24V~<br />

Bell transformers are<br />

short-circuit protected.<br />

Bells/buzzers:<br />

Max. continuous duty<br />

≤ 30 minutes.<br />

Connection capacities : 6▫<br />

Cable clamp type<br />

Output:<br />

Bells: 85 dBA<br />

Buzzers: 78 dBA<br />

When a bell transformer is<br />

installed in an enclosure with<br />

mains voltage equipment, 230V<br />

cable should be used on the<br />

secondary side of the<br />

transformer or extra low voltage<br />

cable should be sheathed within<br />

the enclosure.<br />

Note:<br />

the transformers have a<br />

higher no load voltage.<br />

The stated voltages<br />

correspond to the<br />

voltages on nominal<br />

load.<br />

For technical details<br />

see page 421<br />

<strong>Modular</strong><br />

devices<br />

Designation Characteristics Width in I Pack Cat.<br />

17.5mm qty. ref.<br />

Safety transformers 16VA 50/60Hz 4 1 ST313<br />

230V 12-24V~ 25VA 50/60Hz 4 1 ST312<br />

50/60Hz<br />

40VA 50/60Hz 4 1 ST314<br />

63VA 50/60Hz 6 2 ST315<br />

ST313<br />

Bell transformers 230V/8-12V~ 50/60Hz 2 6 ST301<br />

4VA - 8-12V : 0.33A<br />

230V/8-12V~ 50/60Hz 2 6 ST303<br />

8VA - 8V : 1A<br />

12V : 0.67A<br />

230V/8-12V~ 50/60Hz 3 1 ST305<br />

16VA - 8V : 2A<br />

12V : 1.33A<br />

24V : 0.67A<br />

ST301<br />

Bells 8/12V~ 1 12 SU212<br />

5VA - 0.33A<br />

230V~ 1 12 SU213<br />

6.5VA - 0.03A<br />

SU212<br />

Buzzers 8/12V~ 1 12 SU214<br />

4VA - 0.35A<br />

230V~ 1 12 SU215<br />

6.5VA - 0.03A<br />

SU214<br />

381


Analogue voltmeters, ammeters<br />

Analogue voltmeters<br />

For domestic and commercial<br />

installations<br />

single phase :<br />

direct connection<br />

three phase :<br />

use of a voltmeter selector<br />

switch SK 602 - see page 38<br />

Frequency : 50/60Hz<br />

Analogue ammeters<br />

For domestic and commercial<br />

installations<br />

Direct reading :<br />

up to 30A<br />

Indirect reading via current<br />

transformers - see page 36<br />

from 50 to 2000A<br />

Connection capacity :<br />

Rigid conductor 10▫<br />

Flexible conductor 6▫<br />

For technical details,<br />

see page 422<br />

Designation Characteristics Width in I Pack Cat.<br />

17.5mm qty. ref.<br />

Voltmeter accuracy : 2% 4 1 SM500<br />

consumption : 2.5VA<br />

0 - 500V<br />

SM500<br />

Analog ammeters 0 - 5A 4 1 SM005<br />

direct<br />

0 - 15A 4 1 SM015<br />

0 - 30A 4 1 SM030<br />

SM030<br />

Ammeters accuracy : 2%<br />

current transformer (CT)<br />

operated<br />

- reading via CT SR 051 scale : 0 - 50A 4 1 SM050<br />

- reading via CT SR 101 scale : 0 - 100A 4 1 SM100<br />

- reading via CT SR 150 scale : 0 - 150A 4 1 SM150<br />

- reading via CT SR 250 scale : 0 - 250A 4 1 SM250<br />

- reading via CT SR 400 scale : 0 - 400A 4 1 SM400<br />

- reading via CT SR 600 scale : 0 - 600A 4 1 SM600<br />

- reading via CT SR 800 scale : 0 - 800A 4 1 SM800<br />

- reading via CT SR 850 scale : 0 - 1000A 4 1 SM850<br />

- reading via CT SR 900 scale : 0 - 1500A 4 1 SM900<br />

- reading via CT SR 910 scale : 0 - 2000A 4 1 SM910<br />

382


Digital voltmeters, ammeters<br />

Digital voltmeters<br />

SM501<br />

For domestic and commercial<br />

installations.<br />

three phase :<br />

use of a voltmeter selector<br />

switch SK 602<br />

Digital ammeters<br />

from SM 020 to SM 911<br />

SM 020 : direct reading<br />

from SM 151 to SM 911 :<br />

reading via a current transformer<br />

(see below)<br />

For technical details,<br />

see page 422<br />

Designation Characteristics Width in I Pack Cat.<br />

17.5mm qty. ref.<br />

Digital voltmeter voltage rating :<br />

220/230V; 50/60Hz<br />

accuracy : ±1%<br />

consumption : 4VA<br />

scale : 0 -500V 4 1 SM501<br />

<strong>Modular</strong><br />

devices<br />

SM501<br />

Digital ammeters voltage rating :<br />

220/230V; 50/60Hz<br />

accuracy : ±1%<br />

consumption : 4VA<br />

- direct scale : 0-20A 4 1 SM020<br />

- reading via CT150/5A scale : 0-150A 4 1 SM151<br />

(SR 150)<br />

- reading via CT 400/5A scale : 0-400A 4 1 SM401<br />

(SR 400)<br />

- reading via CT 600/5A scale : 0-600A 4 1 SM601<br />

(SR 600)<br />

SM020<br />

- reading via CT 800/5A scale : 0-800A 4 1 SM801<br />

(SR 800)<br />

- reading via CT 1500/5A scale : 0-1500A 4 1 SM901<br />

(SR 900)<br />

- reading via CT 2000/5A scale : 0-2000A 4 1 SM911<br />

(SR 910)<br />

383


Digital multimeter<br />

Multimeter<br />

For monitoring the electrical<br />

network : single, two or three<br />

phases (with or without neutral).<br />

Connection on current<br />

transformer (not provided).<br />

Enables to display 3 electrical<br />

values at the same time, in type<br />

instantaneous, average or<br />

maximum (voltage and intensity<br />

per phase in RMS value).<br />

For monitoring of power<br />

generator, it measures the<br />

frequency and working time.<br />

For technical details,<br />

see page 423<br />

Designation<br />

Characteristics<br />

Width in ❚<br />

17.5 mm<br />

Pack<br />

qty<br />

Ref.<br />

Multimeter<br />

- 3 voltmeters : 35 to 480 V<br />

- 3 ammeters per<br />

transformer 0-5 A : 5 to 600 A<br />

- mesure of frequency :<br />

40 to 80 Hz<br />

- hourly metering<br />

4<br />

1 SM001<br />

SM001<br />

384


Current transformers (C.T.)<br />

Description :<br />

Current transformers are used to<br />

feed analogue and digital<br />

ammeters. As well as kWh<br />

meters.<br />

Their current on secondary<br />

circuit (0-5A) is proportional to<br />

the current on primary circuit<br />

class : 1<br />

can be mounted on copper bar<br />

or on cable<br />

can be mounted on DIN rail with<br />

adaptors<br />

For technical details,<br />

see page 424<br />

Designation Characteristics Width in I Pack Cat.<br />

17.5mm qty. ref.<br />

<strong>Modular</strong><br />

devices<br />

Current transformers (CT) ratio :<br />

50/5 2,5 1 SR051<br />

100/5 2,5 1 SR101<br />

SR051<br />

150/5 3,5 1 SR150<br />

200/5 3,5 1 SR200<br />

250/5 3,5 1 SR250<br />

SR200<br />

300/5 4,5 1 SR300<br />

400/5 4,5 1 SR400<br />

600/5 4,5 1 SR600<br />

800/5 5,5 1 SR800<br />

1000/5 6 1 SR850<br />

1500/5 6 1 SR900<br />

2000/5 6 1 SR910<br />

385


Selector switches for voltmeters and ammeters<br />

Description<br />

To provide command signals or<br />

program selection in electrical<br />

control schemes<br />

Application<br />

For domestic and commercial<br />

installations<br />

Connection capacity :<br />

Rigid conductor : 1.5 to 10▫<br />

Flexible conductor : 1 to 6▫<br />

Conform to IEC947-3<br />

BS EN 60947-3<br />

Isolating voltage : 500Vac<br />

Nominal current : 10-20A<br />

Designation Characteristics Width in I Pack Cat.<br />

17.5mm qty. ref.<br />

1 pole selector switch 20A 400V~ 3 1 SK600<br />

non spring return<br />

1 3<br />

0<br />

1 2<br />

2<br />

2 pole selector switch 20A 400V~ 3 1 SK601<br />

0<br />

non spring return<br />

1<br />

3<br />

5 7<br />

1<br />

2<br />

SK600<br />

2<br />

6<br />

Voltmeter selector 20A 400Vac 3 1 SK602<br />

3Ph&N<br />

3 readings between phases<br />

3 readings between phase & neutral<br />

null position (no reading)<br />

SK602<br />

Ammeter selector 20A 400Vac 3 1 SK603<br />

4 positions<br />

use in 3Ph&N<br />

reading by phase<br />

null position (no reading)<br />

should be used with current transformer (CT)<br />

SK603<br />

Step selector switch 20A 400V~ 3 1 SK604<br />

2<br />

3<br />

4<br />

5 3 7<br />

1<br />

1<br />

2<br />

0<br />

Key selector switch 10A 400V~ 3 1 SK606<br />

1<br />

3<br />

0<br />

1<br />

1<br />

2<br />

4<br />

0<br />

SK606<br />

386


Kilowatt hours meters and hours counter ...<br />

57<br />

41<br />

45<br />

Description<br />

Kilowatt hours meters measure<br />

the active energy used in an<br />

electric installation. The range<br />

includes meters with pulsed<br />

output for remote indication or<br />

linking into an energy<br />

management system.<br />

Kwh meters can be used for<br />

local metering of installation or<br />

monitoring of power<br />

consumption in individual<br />

machines.<br />

Technical data<br />

In accordance to IEC1036,<br />

- with pulse output<br />

100Wh/pulse (except EC110 and<br />

EC050)<br />

- all meters offer part (resettable)<br />

counter and total (non<br />

resettable) counter (except<br />

EC110, EC050 and EC051)<br />

- display with LCD<br />

- accuracy : class II (EC050 and<br />

EC051 class I)<br />

- for CT (current transformers),<br />

see page 385<br />

For technical details,<br />

see pages 426<br />

Designation Characteristics Width in I Pack Cat.<br />

17.5mm qty. ref.<br />

Single phase<br />

230V +/- 20% 50/60Hz<br />

<strong>Modular</strong><br />

devices<br />

- direct reading 32A single tariff 3 1 EC110<br />

without pulsed output<br />

1 1 EC050<br />

EC051<br />

single tariff 3 1 EC111<br />

with pulsed output<br />

1 1 EC051<br />

Single phase 230V 50Hz 3 1 EC120<br />

CT operated<br />

100/5A CT operated<br />

single tariff<br />

EC111<br />

230V 50Hz 3 1 EC121<br />

100/5A CT operated<br />

dual tariff<br />

Three phase 230V/400V 50Hz 7 1 EC310<br />

CT operated<br />

800mA to 80A<br />

single tariff<br />

230V/400V 50Hz 7 1 EC311<br />

800mA to 80A<br />

dual tariff<br />

Three phase 230V/400V 50Hz 4 1 EC320<br />

CT operated<br />

50-1500/5A CT operated<br />

single tariff<br />

EC121<br />

230V/400V 50Hz 4 1 EC321<br />

50-1500/5A CT operated<br />

dual tariff<br />

Sealing kit for single phase Kwh meters 1 EC001<br />

direct reading only<br />

(EC 110, EC 111)<br />

Hours counter 230V 50Hz 2 1 EC100<br />

EC100<br />

387


Control relays ...<br />

Control relays are used in installations<br />

where the current or the<br />

voltage fluctuation may damage<br />

equipments.<br />

The range is composed of<br />

modular devices :<br />

Voltage control relays dedicated<br />

to protect air conditioning equipments<br />

:<br />

EU 100, EU 101 single phase<br />

EU 301 three phase<br />

Voltage control relay used to<br />

survey DC or AC voltage :<br />

EU 102 single phase product to<br />

monitor DC or AC<br />

EU 302 three phase control relay<br />

used to check AC voltage<br />

Current control relay used to<br />

survey DC or AC current :<br />

EU 103 single phase product to<br />

monitor DC or AC current direct<br />

via current transformer<br />

Phase control relay<br />

EU 300 to verify phase parameters<br />

(asymmetry, loss of phase,<br />

undervoltage)<br />

The two digital control relays<br />

EU 102 and EU 103 are<br />

equipped with an LCD indicator.<br />

During normal operation, the<br />

LCD displays the measured<br />

voltage (EU 102) or current<br />

(EU 103). The LCD and the local<br />

pushbuttons are also used to<br />

enter the parameter settings<br />

(type of signal, monitored levels,...)<br />

In case of an error, the relay will<br />

close a contact (changeover<br />

contact 8A)<br />

For technical information<br />

see page 429<br />

Designation characteristics Width in I Pack Cat.<br />

17.5mm qty. ref.<br />

Single phase compressor Power supply 230V AC 2 1 EU100<br />

control relay<br />

Under/over voltage control<br />

Umin : 0,75 Un - Umax : 1,2 Un<br />

Restart duration (5 or 10 minutes)<br />

selected via bridge<br />

Output : changeover contact<br />

8A AC1 250V~<br />

EU100<br />

Single phase compressor Power supply 230V AC 2 1 EU101<br />

control relay<br />

Under/over voltage control<br />

Umin/Umax : +/-5% to +/-20% Un<br />

set via potentiometer<br />

Restart duration (5 or 10 minutes)<br />

selected via switch<br />

Output : changeover contact<br />

8A AC1 250V~<br />

Three phase compressor Power supply 400V AC 2 1 EU301<br />

control relay<br />

Under/over voltage control<br />

Umin/Umax : +/-5% to +/-20% Un<br />

set via potentiometer<br />

Restart duration (5 or 10 minutes)<br />

selected via switch<br />

Output : changeover contact<br />

8A AC1 250V~<br />

EU301<br />

Phase control relay Power supply 400V AC 2 1 EU300<br />

Under / over voltage control<br />

Loss of phase, phase order control<br />

Asymetry control : +/-5% to +/-20%<br />

set via potentiometer<br />

Output : changeover contact<br />

8A AC1 250V~<br />

388


... Control relays<br />

Designation characteristics Width in I Pack Cat.<br />

17.5mm qty. ref.<br />

Voltage control relay Power supply 230V~ 2 1 EU102<br />

with LCD<br />

Voltage monitored DC 15 to 700V<br />

or AC 15 to 480V~<br />

Under / over voltage or both<br />

control bands<br />

Parameter setting via pushbutton<br />

and LCD indicator<br />

Output : changeover contact<br />

8A AC1 250V~<br />

EU102<br />

Three phase voltage Power supply Un 400V~ 2 1 EU302<br />

control relay<br />

Under/over voltage control<br />

Umin/Umax : +/-5% to +/-20% Un<br />

set via potentiometer<br />

Output : changeover contact<br />

8A AC1 250V~<br />

<strong>Modular</strong><br />

devices<br />

Current control relay Power supply Un 230V~ 2 1 EU103<br />

single phase with LCD<br />

Current control DC or AC,<br />

direct 0,1A to 10A or via current<br />

transformer<br />

Under / over current or<br />

both control bands<br />

Parameter setting via pushbutton<br />

and LCD indicator<br />

Output : changeover contact<br />

8A AC1 250V~<br />

389