Modular Automation Devices - Hager
Modular Automation Devices - Hager
Modular Automation Devices - Hager
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Modular</strong><br />
<strong>Modular</strong><br />
devices
<strong>Modular</strong> <strong>Devices</strong> -<br />
Indicators and Push Buttons<br />
The new range of indicator<br />
lights and push buttons<br />
replaces and expands upon<br />
the whole SV range and is<br />
composed of the following<br />
three families<br />
• Indicator Lights in various<br />
colours such as red,<br />
green, orange, blue and<br />
clear.<br />
• Push Buttons in various<br />
contact types (NO, NC,<br />
NO+NC in 1 or 2 poles)<br />
and buttons (latching or<br />
impulse).<br />
• Indicator Lights and Push<br />
Buttons, an association of<br />
the above two solutions.<br />
New LED technology provides longer<br />
life.<br />
Updated and modernised<br />
appearance.<br />
Integrated label holder.<br />
352
Latching relays 354<br />
<strong>Modular</strong><br />
devices<br />
Relays 356<br />
Interface relays 356<br />
Contactors<br />
& override contactors 357<br />
Low noise contactors 358<br />
Electromechanical and<br />
digital timers selection<br />
guide 359<br />
Electromechanical<br />
time switches 360<br />
Digital time switches 362<br />
4 channel digital<br />
time switches 362<br />
Light sensitive switch 364<br />
Light sensitive<br />
programmer 364<br />
Presence Detectors 365<br />
Delay timers 367<br />
Time lag switches 368<br />
Emergency<br />
lighting module 369<br />
Switch disconnector 374<br />
Trip Free Switches 375<br />
2 way / centre-off<br />
changeover<br />
modular switches 376<br />
Pushbuttons -<br />
Impulse 377<br />
Pushbuttons -<br />
Latching 378<br />
Indicator lights 381<br />
Transformers,<br />
bells and buzzers 381<br />
Analogue voltmeters,<br />
ammeters 382<br />
Digital voltmeters 383<br />
Current transformers 385<br />
Selector switches<br />
for voltmeters<br />
and ammeters 386<br />
kiloWatt hour meters 387<br />
Hours counter 387<br />
Control Relays 388<br />
353
Latching relays<br />
Description<br />
For the control of lighting<br />
circuits in private buildings,<br />
small industry buildings and<br />
administration buildings.<br />
Latching relays - operate when<br />
impulsed by a signal voltage.<br />
The impulse can be provided via<br />
a pushbutton or switch. The first<br />
pulse operates the relay and<br />
latches it into its set (opposite)<br />
state, the next operation of the<br />
pushbutton returns the relay into<br />
its reset (original) state.<br />
The latching relays are built to<br />
add on optionally the following<br />
auxiliaries :<br />
- an auxiliary for centralised<br />
ON/OFF control EPN050<br />
- an auxiliary contact for<br />
remote signalling EPN051<br />
- an auxiliary for multi levelled<br />
centralised control EPN052<br />
- an auxiliary for control by<br />
maintained contact EPN053.<br />
Connection capacity<br />
10▫ rigid cables<br />
6▫ flexible cables<br />
Conform to standard EN669-1<br />
and EN669-2-2<br />
For technical details<br />
see page 390<br />
Designation Type Coil Coil Power Width in I Pack Cat.<br />
VAC VDC Circuit 17.5mm qty. ref.<br />
50/60Hz<br />
AC1<br />
Latching relays 1NO 230 110 16A-250V 1 1 EPN510<br />
A1<br />
1<br />
48 24 16A-250V 1 1 EPN501<br />
A2<br />
2<br />
24 12 16A-250V 1 1 EPN513<br />
12 - 16A-250V 1 1 EPN511<br />
8 - 16A-250V 1 1 EPN512<br />
A1<br />
1<br />
3<br />
2NO 230 110 16A-250V 1 1 EPN520<br />
A2<br />
2<br />
4<br />
110 48 16A-250V 1 1 EPN523<br />
EPN510<br />
48 24 16A-250V 1 1 EPN526<br />
24 12 16A-250V 1 1 EPN524<br />
12 - 16A-250V 1 1 EPN521<br />
8 - 16A-250V 1 1 EPN522<br />
A1<br />
1<br />
3<br />
1NC+1NO 230 110 16A-250V 1 1 EPN515<br />
A2<br />
2<br />
4<br />
110 48 16A-250V 1 1 EPN516<br />
48 24 16A-250V 1 1 EPN503<br />
EPN515<br />
24 12 16A-250V 1 1 EPN518<br />
12 - 16A-250V 1 1 EPN519<br />
A1<br />
1<br />
3<br />
5<br />
7<br />
4NO 230 110 16A-400V 2 1 EPN540<br />
A2<br />
2<br />
4<br />
6<br />
8<br />
48 24 16A-400V 2 1 EPN548<br />
24 12 16A-400V 2 1 EPN541<br />
EPN525<br />
A1<br />
1<br />
3<br />
5<br />
7<br />
2NC+2NO 230 110 16A-250V 2 1 EPN525<br />
A2<br />
2<br />
4<br />
6<br />
8<br />
24 12 16A-250V 2 1 EPN528<br />
A1<br />
1<br />
3<br />
5<br />
7<br />
3NO+1NC 230 110 16A-400V 2 1 EPN546<br />
EPN540<br />
A2<br />
2<br />
4<br />
6<br />
8<br />
354
Latching relays auxiliaries<br />
Auxiliaries for centralised<br />
control<br />
The EPN050 allows the<br />
centralised control of several<br />
light sources which can be<br />
turned on or off simultaneously<br />
the separate switching by<br />
pushing the pushbuttons, which<br />
are connected with the latching<br />
relay, remains possible.<br />
The EPN052 allows a generic<br />
central control of individual<br />
central on/off EPN050<br />
Auxiliary contact<br />
A remote signalling can be<br />
realised with the auxiliary<br />
contact EPN051.<br />
Auxiliary for control by<br />
maintained contact<br />
When control devices with<br />
permanent impulse are<br />
externally driven, e.g. time<br />
switches or limit switches, an<br />
impulse control directly to the<br />
latching relay’s coil is possible<br />
with the auxiliary contact EP 053.<br />
Connection latching relay +<br />
auxiliary<br />
Several auxiliaries can be<br />
combined with the latching relay.<br />
Connection capacity<br />
10▫ rigid cables<br />
6▫ flexible cables<br />
For technical details<br />
see page 392<br />
<strong>Modular</strong><br />
devices<br />
Designation Voltage supply Width in I Pack Cat.<br />
17.5mm qty. ref.<br />
Auxiliary for 24 to 230V AC 1/2 1 EPN050<br />
centralised control<br />
11<br />
12 14<br />
EPN050<br />
Auxiliary contact 2A - 250 V AC 1/2 1 EPN051<br />
21 23<br />
22 24<br />
EPN051<br />
Auxiliary for 24 to 230V AC 1/2 1 EPN052<br />
multi levelled<br />
centralised control<br />
31 33<br />
32 34<br />
EPN052<br />
Auxiliary for 24 to 230V AC 1/2 1 EPN053<br />
control by<br />
maintained contact<br />
11<br />
12 14<br />
EPN053<br />
355
Relays<br />
Description<br />
To provide command of low<br />
power circuits max 16A;<br />
associated with pushbuttons<br />
switches, time switches etc to<br />
provide for remote control applications.<br />
For the command of high power<br />
circuits (25, 40, 63Amps) use<br />
contactors as shown on<br />
page 357.<br />
The relays will accept an<br />
auxiliary contact for remote<br />
signalling applications.(EP071)<br />
For the command of VLV circuits<br />
use interface relays EN145 and<br />
EN146.<br />
For technical details<br />
see page 393<br />
Designation Type Coil Power Width in I Pack Cat.<br />
Circuit 17.5mm qty. ref.<br />
AC1<br />
Relays 1NC+1NO 230V 50Hz 16A-250V 1 12 ER120<br />
24V 50Hz 16A-250V 1 12 ER123<br />
12V 50Hz 16A-250V 1 12 ER124<br />
2NC+2NO 230V 50Hz 16A-250V 2 1 ER135<br />
ER120<br />
24V 50Hz 16A-250V 2 1 ER138<br />
12V 50Hz 16A-250V 1 1 ER139<br />
Auxiliary contact 2A-250V 1/2 1 EP071<br />
ER138<br />
Interface relays<br />
Description<br />
To interface between low voltage<br />
and very low voltage circuits to<br />
ensure galvanic isolation<br />
between LV and VLV to 4kV.<br />
Application<br />
Interface between fire alarm,<br />
burglar alarm and other VLV<br />
systems and main distribution<br />
circuits.<br />
Connection capacity<br />
6▫ rigid cables<br />
4▫ flexible cables<br />
For technical details<br />
see page 394<br />
Designation Characteristics Width in I Pack Cat.<br />
17.5mm qty. ref.<br />
Interface relays coil voltage : 1 1 EN145<br />
VLV/LV 1 way<br />
10 to 26V AC/DC<br />
A1 1<br />
output : 1 changeover contact<br />
max. 5A 230V~ -<br />
A2 2 4<br />
min. 10mA - 12V DC<br />
EN145<br />
356<br />
VLV/LV 1 way coil voltage : 1 1 EN146<br />
A1 1<br />
230V~ 50Hz<br />
output : 1 changeover contact<br />
A2 2 4<br />
max. 5A 230V~<br />
min. 10mA - 12V DC
Contactors and override contactors<br />
Description<br />
Contactors<br />
For the remote switching and<br />
control of power circuits<br />
(25A-63A AC1)<br />
Override contactors<br />
allows : - permanent ON<br />
- permanent OFF<br />
Technical data<br />
The choice of contactor<br />
depends upon a number of<br />
parameters, e.g.<br />
- the nature of the supply.<br />
- the power it is switching.<br />
- the characteristics of the load.<br />
- the control voltage required.<br />
- number of operations<br />
All contactors ratings are for<br />
AC1 loads only – if the load<br />
differs from AC1 the contactor<br />
may need de-rating<br />
The use of LZ 060<br />
(heat dissipation inserts)<br />
between all contactors<br />
installed or between<br />
contactors and adjacent<br />
devices is recommended.<br />
Options<br />
Contact choice<br />
- normally open (NO)<br />
- normally closed (NC)<br />
LZ 060 heat dissipation inserts.<br />
Auxiliary<br />
25A contactors will accept<br />
auxiliary, EP 071 contact.<br />
For technical details<br />
see pages 393-395<br />
<strong>Modular</strong><br />
devices<br />
Designation Type Coil Power Width in I Pack Standard Override<br />
AC Circuit 17.5mm qty. cat. ref. cat. ref.<br />
50/60Hz 50/60Hz<br />
Contactors 1NO 230V 25A-250V 1 1 ES110 ES110A<br />
1NO+1NC 230V 25A-250V 1 1 ES210<br />
110V 25A-250V 1 1 ES216<br />
24V 25A-250V 1 1 ES239<br />
ES230<br />
2NO 230V 25A-250V 1 12 ES220 ES220A<br />
40A-400V 3 1 ES240<br />
63A-400V 3 1 ES263<br />
110V 25A-250V 1 1 ES226<br />
24V 25A-250V 1 1 ES224 ES224A<br />
40A-400V 3 1 ES252<br />
63A-400V 3 1 ES262<br />
2NC 230V 25A-250V 1 12 ES230 ES230A<br />
110V 25A-250V 1 1 ES236<br />
3NO 230V 25A-400V 2 6 ES320 ES320A<br />
230V 40A-400V 3 1 ES340<br />
ES320<br />
3NO+1NC 230V 25A-400V 2 1 ES444<br />
40A-400V 3 1 ES345<br />
63A-400V 3 1 ES365<br />
4NO 230V 25A-400V 2 6 ES420 ES420A<br />
40A-400V 3 1 ES440<br />
63A-400V 3 1 ES463<br />
110V 25A-400V 2 1 ES426<br />
40A-400V 3 1 ES446<br />
63A-400V 3 1 ES466<br />
24V 25A-400V 2 1 ES424 ES424A<br />
40A-400V 3 1 ES442<br />
63A-400V 3 1 ES462<br />
ES463<br />
4NC 230V 25A-400V 2 6 ES430 ES430A<br />
40A-400V 3 1 ES480<br />
63A-400V 3 1 ES490<br />
110V 25A-400V 2 1 ES426<br />
40A-400V 3 1 ES436<br />
63A-400V 3 1 ES496<br />
24V 25A-400V 2 1 ES432<br />
63A-400V 3 1 ES492<br />
13<br />
14<br />
11<br />
12<br />
2NO+2NC 230V 25A-250V 2 1 ES450<br />
63A-250V 3 1 ES470<br />
24V 25A-250V 2 1 ES242<br />
13 11<br />
Auxiliary 2A-250V 1/2 1 EP071<br />
14<br />
12<br />
Heat dissipation insert 1/2 10 LZ060<br />
357
Low Noise Contactors<br />
Description<br />
For the remote switching and<br />
control of power circuits<br />
(20A-63A AC1)<br />
Technical data<br />
The choice of contactor<br />
depends<br />
upon a number of parameters,<br />
e.g.<br />
• The nature of the supply.<br />
• The power it is switching.<br />
• The characteristics of the load.<br />
• The control voltage required.<br />
• Number of operations<br />
All contactors ratings are for<br />
AC1<br />
loads only – if the load<br />
differs from AC1 the contactor<br />
may need de-rating.<br />
The use of LZ060 (heat<br />
dissipation inserts) between all<br />
contactors installed or<br />
between contactors and<br />
adjacent devices is<br />
recommended.<br />
Options<br />
Contact choice<br />
• Normally open (NO)<br />
• Normally closed (NC)<br />
Designation Type Coil Power Width in I Pack cat. ref<br />
AC voltage circuit AC1 17.5mm qty.<br />
2 NO 230V 50 Hz 25A - 250V 1 12 ESN220B<br />
40A - 400V~ 3 4 ESN240B<br />
63A - 400V~ 3 4 ESN263B<br />
3 NO 230V 50 Hz 25A - 400V 2 6 ESN320B<br />
ESN420B<br />
40A - 400V~ 3 4 ESN340B<br />
3 NO + 1 NC 230V 50 Hz 25A - 250V 2 6 ESN444B<br />
4 NO 230V 50 Hz 25A - 400V 2 6 ESN420B<br />
230V 50 Hz 40A - 400V~ 3 4 ESN440B<br />
230V 50 Hz 63A - 400V~ 3 4 ESN463B<br />
4 NC 230V 50 Hz 25A - 400V 2 6 ESN430B<br />
ESN440B<br />
Auxiliary Contact 1NO + 1NC 6 A - 250V 1/2 1 ESN071B<br />
Cover for 2 module contactors 2 10 ESN002B<br />
Cover for 3 module contactors 3 10 ESN003B<br />
358
Time switches and twilight switches selection chart<br />
Analogue time switches<br />
(din rail mounted) :<br />
Analogue time switches<br />
(72 x 72mm) :<br />
<strong>Modular</strong><br />
devices<br />
width in 1 ❚ :<br />
EH 010, EH 011<br />
width in 3 ❚ :<br />
EH 110, EH 111,<br />
EH 171<br />
width in 5 ❚ :<br />
EH 191<br />
EH 710, EH 711, EH 770<br />
EH 771, EH 712, EH 715<br />
EH 716<br />
Analogue time switches (din rail mounted)<br />
Analogue time switches (72 x 72mm)<br />
Technical<br />
characteristics EH 010 EH 011 EH 110 EH 111 EH 171 EH 191 EH 710 EH 711 EH 770 EH 771 EH 712 EH 715 EH 716<br />
Width in 1 1 3 3 3 5 - - - - - - -<br />
❚ 17.5mm<br />
Voltage 230V 230V 230V 230V 230V 230V 230V 230V 230V 230V 230V 48V DC<br />
supply<br />
110-240VAC<br />
Operating 24 hrs. 24 hrs. 24 hrs. 24 hrs. 7 days 24 hrs./ 24 hrs. 24 hrs. 7 days 7 days 24 hrs. 24 hrs. 24 hrs.<br />
cycle<br />
7 days<br />
Minimum 15 min 15 min 15 min 15 min 2 hrs. 15 min/ 20 min 20 min 2 hrs. 2 hrs. 20 min 20 min 20 min<br />
switching<br />
2 hrs.<br />
Supply failure - 200 hrs. - 200 hrs. 200 hrs. 200 hrs. - 200 hrs. - 200 hrs. - - 200 hrs.<br />
reserve<br />
Manual auto/ auto/ auto/ auto/ auto/ auto/ on/off on/off on/off on/off on/off on/off on/off<br />
override on on on/off on/off on/off on/off<br />
Digital time switches<br />
(din rail mounted) :<br />
Twilight switches<br />
(din rail mounted) :<br />
width in 1 ❚ :<br />
EG 010, EG 071<br />
width in 3 ❚ :<br />
EG 110, EG 170,<br />
EG 171,<br />
EG 210, EG 270<br />
width in 5 ❚ :<br />
EG 470<br />
EE 170<br />
Digital time switches (din rail mounted)<br />
Twilight switches<br />
Technical<br />
characteristics EG010 EG071 EG110 EG170 EG103B/E EG171 EG210 EG270 EG203B/E EG470 EE100 EE101 EE110 EE170 EE171<br />
Width in ❚17.5mm1 1 3 3 2 3 3 3 2 5 3 3 5 3 3<br />
Operating cycles 24hrs 7days 24hrs 7days 7 days 7days 24hrs 7days 7days 7days - - 24hrs 7days 7days<br />
Program steps 5 20 20 20 56 20 20 20 56 84 - - 15min 1min 1min<br />
Voltage supply 230V 230V 230V 230V 230V 230V 110/ 110/ 230V 230V 230V 230V 230V 230V 230V<br />
& DC 230V 230V<br />
N° of channels 1 1 1 1 1 1 2 2 2 4 - - 1 1 1<br />
(pulsed<br />
output)<br />
359
Analogue time switches modular<br />
Description<br />
Electromechanical time<br />
switches 1 channel for daily or<br />
weekly programming.<br />
To control lighting, heating,<br />
household appliances, shop<br />
windows etc...<br />
To improve comfort and save<br />
energy.<br />
Applications<br />
Domestic and commercial<br />
premises.<br />
DIN rail mounting<br />
Complies with EN60730<br />
Technical data<br />
- programming by captive<br />
segments.<br />
- manual override :<br />
On 1 module devices :<br />
- automatic<br />
- permanent ON<br />
On 3 and 5 module devices :<br />
- automatic<br />
- permanent ON<br />
- permanent OFF<br />
Minimum switching time:<br />
- 15 min for daily versions<br />
- 2 hours for weekly versions<br />
- 15 min and 2 hours on the<br />
daily+weekly version<br />
Connection capacity :<br />
1 to 4▫<br />
For technical details<br />
see page 396<br />
Designation Characteristics Width in I Pack Cat.<br />
17.5mm qty. ref.<br />
1 channel voltage supply : 230V<br />
daily dial<br />
50/60Hz<br />
without battery reserve output :<br />
1M devices = 1NO 1 1 EH010<br />
16A - 250V AC1<br />
3M devices = 1NO 3 1 EH110<br />
changeover<br />
16A - 250V AC1<br />
EH010<br />
1 channel voltage supply : 230V<br />
daily dial<br />
50/60Hz<br />
with battery reserve output :<br />
1M devices = 1NO 1 1 EH011<br />
16A - 250V AC1<br />
reserve : 3M devices = 1NO 3 1 EH111<br />
200 hours after being changeover<br />
connected for 120 hours<br />
16A - 250V AC1<br />
EH111<br />
1 channel voltage supply : 230V<br />
weekly dial<br />
50/60Hz<br />
with battery reserve output :<br />
1 changeover = 1NO 3 1 EH171<br />
reserve :<br />
16A - 250V AC1<br />
200 hours after being<br />
connected for 120 hours<br />
1 channel voltage supply : 230V<br />
daily + weekly dial<br />
50/60Hz<br />
with battery reserve output :<br />
1 changeover = 1NO 6 1 EH191<br />
reserve :<br />
16A - 250V AC1<br />
200 hours after being<br />
connected for 120 hours<br />
Sealable terminal cover kit<br />
for 3 modules time switches<br />
EH901<br />
Flush mounting kit for<br />
3 modules time switches<br />
EH902<br />
360
Analogue time switches 72 x 72 mm<br />
Description<br />
For daily or weekly<br />
programming.<br />
1 channel for the control of<br />
lighting, heating, household<br />
appliances, shop windows etc..<br />
To improve comfort and save<br />
energy.<br />
segments<br />
- manual override with automatic<br />
return to programme<br />
- operating reserve : 200 hours<br />
after being connected for 120<br />
hours<br />
- output : voltage free<br />
changeover contact 16A/250V<br />
Weekly version :<br />
Programming in steps of one<br />
hour.<br />
- minimum time between<br />
2 switching intervals : 2 hours<br />
- switching accuracy : 10 min<br />
<strong>Modular</strong><br />
devices<br />
Applications<br />
Domestic and commercial<br />
premises.<br />
Complies with EN60730<br />
Daily version :<br />
Programming in steps of<br />
10 minutes.<br />
Minimum time between<br />
2 switching intervals : 20 min<br />
Technical data<br />
- suitable for surface, flush or<br />
din rail mounting<br />
- programming by captive<br />
For technical details<br />
see page 396<br />
Designation Characteristics Pack Cat.<br />
qty.<br />
ref.<br />
1 channel daily cycle supply : 230V 50/60Hz<br />
without battery reserve 1 EH710<br />
with battery reserve 1 EH711<br />
economy version 1 EH712<br />
reserve : 200 hours after being<br />
connected for 120 hours<br />
1 channel weekly cycle supply : 230V 50/60Hz<br />
without battery reserve 1 EH770<br />
with battery reserve 1 EH771<br />
EH770<br />
reserve : 200 hours after being<br />
connected for 120 hours<br />
1 channel daily cycle supply : 48V<br />
110 to 240V 50/60Hz<br />
without battery reserve 1 EH715<br />
with battery reserve 1 EH716<br />
reserve : 200 hours after being<br />
connected for 120 hours<br />
Flush mounting kit<br />
EH900<br />
361
Digital time switches<br />
Description<br />
Use : domestic and commercial<br />
buildings<br />
For the control of lighting, heating,<br />
household appliances, shop<br />
windows, signage etc..., to<br />
improve comfort and to save<br />
energy.<br />
EG103B and EG203B<br />
(basic version)<br />
Product set at current time and<br />
date when delivered.<br />
Automatic change of summer /<br />
winter time.<br />
Programming key :<br />
- to allow easy back up and<br />
re-installation of the program to<br />
allow permanent program overrides.<br />
- programming per day or group<br />
of days<br />
- 56 ON/OFF programme steps<br />
- permanent ON/OFF overrides<br />
- temporary ON/OFF overrides<br />
- bar graph indication showing<br />
the daily profile<br />
- programming without the need<br />
to be energised.<br />
EG103E and EG203E<br />
(evolution version)<br />
Same characteristics as EG103B<br />
and EG203B plus more :<br />
- holidays mode : forcing ON or<br />
OFF between two dates<br />
- presence simulation - random<br />
switching<br />
- backlighted screen<br />
- impulse programming<br />
capability (1s to 30min)<br />
Operating voltage :<br />
230V~ 50/60Hz<br />
For technical details<br />
see page 398<br />
Designation Characteristics Width in I Pack Cat.<br />
17.5mm qty. ref.<br />
1 channel daily cycle 5 adjustable pre-recorded 1 1 EG010<br />
programs : 6 commutations<br />
per day (3 ON and 3 OFF)<br />
230V 50/60Hz<br />
capacity : 20 program steps 3 1 EG110<br />
230V 50/60Hz<br />
EG 071<br />
2 channels daily cycle capacity : 20 program steps to 3 1 EG210<br />
be divided between the<br />
2 channels<br />
110/230V 50/60Hz<br />
1 channel weekly cycle capacity : 20 program steps 1 1 EG071<br />
230V 50/60Hz<br />
capacity : 20 program steps 3 1 EG170<br />
230V 50/60Hz<br />
capacity : 56 program steps 2 1 EG103B<br />
output : 1 changeover contact<br />
µ 16A - 250V~ AC1<br />
EG 210<br />
EG 203E<br />
EG 400 / EG 002<br />
version delivered<br />
with key EG 005 2 1 EG103E<br />
1 channel weekly cycle capacity : 20 program steps 3 1 EG171<br />
pulsed output<br />
230V 50/60Hz<br />
pulsed output adjustable<br />
from 1 sec. to 99 mins.<br />
2 channels weekly cycle capacity : 20 program steps 3 1 EG270<br />
be divided between the 2 channels<br />
110/230v 50/60Hz<br />
capacity : 56 program steps 2 1 EG203B<br />
output : 2 changeover contacts<br />
µ 16A - 250V~ AC1<br />
version delivered<br />
with key EG 005 2 1 EG203E<br />
4 channels weekly cycle capacity : 84 program steps to 5 1 EG470<br />
be divided between the<br />
4 channels.<br />
230V 50/60Hz<br />
4 channels digital time switch capacity : 102 program steps 5 1 EG400<br />
weekly / annual cycle<br />
230V~ 50/60Hz<br />
output : 3 changeover contacts<br />
programm setting :<br />
10A - 250V~ AC1<br />
1 minute increments 1NO contact :<br />
10A - 250V ~ AC1<br />
lithium battery total of 10 years<br />
Programming key for EG 400 1 EG002<br />
Programming key for EG103 / EG 203 1 EG005<br />
Interface and software for computer PC via connection RS232 1 EG003<br />
with software on CD<br />
with USB 1 EG003U<br />
362
Astronomical time switches<br />
Description<br />
The hager range is composed of<br />
two Astronomical time switches<br />
EE180/EE181<br />
That range offers the following<br />
features :<br />
- Programming of the lighting<br />
interruption<br />
- Automatic change of<br />
winter / summer time<br />
- Astro program and expert<br />
program with individual Astro<br />
program steps<br />
- Programming for day or group<br />
of days (same concept than<br />
our existing clocks with key)<br />
- Anticipation ON<br />
- Maintained ON<br />
- Temporary overrides<br />
- Programming of holidays<br />
period<br />
- Programming via the PC<br />
software and the associated<br />
interface (EG003)<br />
- Weekly program<br />
For technical details<br />
see page 403<br />
<strong>Modular</strong><br />
devices<br />
Designation Characteristics Width in I Pack Cat.<br />
17.5mm qty. ref.<br />
Astronomical time switch 230V~ , 50Hz 2 1 EE180<br />
1 channel changeover contact<br />
(weekly cycle)<br />
16A AC1<br />
operating reserve<br />
lithium<br />
delivered with key EG005 battery 5 years<br />
EE180<br />
Astronomical time switch 230V~ , 50Hz 2 1 EE181<br />
2 channels 2 changeover contacts<br />
(weekly cycle)<br />
16A AC1<br />
operating reserve<br />
lithium<br />
delivered with key EG005 battery 5 years<br />
363
Twilight switches<br />
Description<br />
A photo-electric cell measures<br />
the light level and in conjuction<br />
with the relay provides ON / OFF<br />
control of a circuit.<br />
This device controls lighting circuits<br />
in relation to ambient light,<br />
based on user settings.<br />
Front cover sealability<br />
Applications<br />
Street lighting, display lighting,<br />
illuminated signes etc....<br />
Connection<br />
protected cable clamps<br />
capacity :<br />
rigid : 1.5 to 10mm 2<br />
flexible : 1 to 6mm 2<br />
on board LED shows status of<br />
changeover contact.<br />
Technical data<br />
4 position override switch allowing<br />
:<br />
- auto : normal operating mode<br />
- on : permanently switched on<br />
- off : permanently switched off<br />
- test : setting mode for easy<br />
adjustement<br />
output : 1 changeover AC1<br />
contact 16A AC1 230V<br />
8A AC1 (EE701)<br />
Maximum distance : 50m<br />
between photocell and controller<br />
Must be used in conjunction<br />
with a suitable rated contactor<br />
For technical details<br />
see page 403<br />
Designation Characteristics Width in I Pack Cat.<br />
17.5mm qty. ref.<br />
Twilight switch 3 1 EE100<br />
delivered with a separate<br />
surface photo electric cell (EE003)<br />
Twilight switch 3 1 EE101<br />
delivered with a separate<br />
flush photo eletric cell (EE002)<br />
EE110<br />
Programmable twilight daily cycle 5 1 EE110<br />
switch with surface cell<br />
electromech. switch<br />
Programmable twilight weekly cycle 3 1 EE170<br />
switch with surface cell<br />
electronical program<br />
8 presetted programs<br />
EE170<br />
Programmable twilight weekly cycle 3 1 EE171<br />
switch with surface cell<br />
electronical program<br />
free setting<br />
EE702<br />
Compact light switch 230V~ 50 Hz - 1 EE701<br />
basic 8A<br />
normally open contact<br />
(without settings)<br />
(cutting phase)<br />
8A AC1<br />
Fix lux : 10...30lux<br />
IP55 / Integrated cell<br />
Fix ON delay : 40s/OFF delay:120s 1000W incandescent<br />
Compact light switch 230V~ 50 Hz - 1 EE702<br />
enhanced 16A<br />
normally open contact<br />
(with settings)<br />
(cutting phase)<br />
16A AC1<br />
Fix lux : 2 to 1000 lux<br />
IP55 / Integrated cell<br />
Time settings : from 1s to 120s 2300W incandescent<br />
EE002<br />
Flush cell IP54 for EE100, 101, 110 & 170 1 EE002<br />
Surface cell IP54 for EE100, 101, 110 & 170 1 EE003<br />
EE003<br />
364
Comfortable energy saving …<br />
… with the presence detectors<br />
For the control or the regulation of lighting depending on<br />
presence and natural light<br />
The new <strong>Hager</strong> presence detectors with double lens<br />
technique are adapted to all architectural requirements.<br />
Whether for the regulation of the light depending on occupancy<br />
or simply to switch on the lights depending on presence<br />
and ambient luminosity, the <strong>Hager</strong> presence detectors<br />
offer the necessary flexibility for each application.<br />
Ventilation, ambient temperature or alarms can also be piloted<br />
exclusively by the detection of a movement thanks to the<br />
second channel. A pushbutton connected on the override entry<br />
makes it for example possible to cut the light or reduce it to<br />
the wished level during a presentation.<br />
<strong>Modular</strong><br />
devices<br />
An exciting technique<br />
The patented double lens technique<br />
ensures a very precise<br />
detection on 360° of a person<br />
moving on an area up to<br />
13 x 7 m. The integrated<br />
lux-meter makes it also possible<br />
to differentiate the proportion of<br />
natural and artificial light.<br />
Rotating and adaptable<br />
According to the architectural<br />
constraints, the detection zone<br />
can be adjusted with precision<br />
thanks to the rotation of lens on<br />
90°.<br />
Override<br />
The command entry on the 2<br />
channel presence detector<br />
(EE811) and on the presence<br />
regulator (EE812) allows the<br />
commutation of a lighting circuit<br />
(for example via a pushbutton).<br />
This facility is ideal for presentations<br />
during which the room must<br />
completely or partially darkened.<br />
When not more presence is detected<br />
the module will return to the<br />
automatic mode after the preselected<br />
time delay. Manual dimming<br />
is also possible via the same<br />
command entry on the presence<br />
regulator.<br />
Regulation with constant lighting<br />
: nearly a must in all<br />
open-plan offices. The presence<br />
regulator (EE812) adapts the<br />
artificial light depending on<br />
natural light and presence. The<br />
light intensity constantly remains<br />
fixed according to the preselected<br />
set point. An<br />
effective and pleasant lighting<br />
can be carried out easily and<br />
quickly with electronic regulators<br />
or the <strong>Hager</strong> 1000W dimmer.<br />
released after 15 minutes for<br />
the EE812 model.<br />
Master and slave : evolutionary<br />
for wide control<br />
The presence detectors can be<br />
connected between them for<br />
corridors or large premises. The<br />
Slave module will for example<br />
detect a presence, inform the<br />
Master module which then commands<br />
the light depending on<br />
luminosity, override and duration<br />
of lighting.<br />
Benefits :<br />
■ Models with 1 or 2 channels<br />
■ Regulators of presence /<br />
light<br />
■ Detection zone of 360°<br />
on 13 x 7 m<br />
■ Override entry or manual<br />
dimming<br />
■ Natural and artificial light<br />
measuring<br />
■ Wide setting possibilities<br />
■ Basic lighting mode on<br />
presence regulators EE812<br />
■ Master/Slave function<br />
Settings : lighting, time delay<br />
and manual dimming. Adjustable<br />
from 5 to 1200 Lux, the lighting/variation<br />
can also be setted<br />
manually via the command entry<br />
on the presence regulator. The<br />
time delay of the lighting and<br />
presence channel can be selected<br />
individually from 30 seconds<br />
to 1 hour.<br />
Basic lighting mode : for safety<br />
in hotels, homes, hospitals and<br />
corridors. The detector will<br />
switch on the lighting channel in<br />
case of presence. The time delay<br />
begins once no more presence<br />
is detected. The light will then be<br />
reduced to the selected value<br />
between 0 and 50%, then<br />
comprehensive<br />
settings<br />
rectangular capture<br />
zone<br />
natural and artificial<br />
light measure<br />
rotating front<br />
lens<br />
365
Conventional presence detectors<br />
Description<br />
EE810, EE811 and EE812<br />
High performance presence<br />
detector that will be used in<br />
premises or in passage areas,<br />
where they increase comfort and<br />
reduce drastically the energy<br />
costs.<br />
Combination of a presence<br />
area and a motion area. The<br />
presence area is especially interesting<br />
in offices, where the<br />
motion area may be used in long<br />
corridors.<br />
Head rotation for detection area<br />
adjustment<br />
Settings via potentiometers<br />
Applications<br />
EE810 - 1 channel detector<br />
Direct control of a light load or<br />
used as a slave for detection<br />
area enlargement.<br />
Lux level and ON delay setting<br />
via potentiometers<br />
Test mode in order to set lux<br />
level and the detection pattern<br />
EE811 - 2 channels detector<br />
Light relay output for direct<br />
control of a light load<br />
Presence output potential free<br />
relay.<br />
Lux level, on delay setting for<br />
light channel and presence<br />
channel via potentiometers<br />
Input for slave (EE810) and/or<br />
derogation push button.<br />
EE812 - Light regulator 1/10V<br />
Light regulator with 1/10V output<br />
in order to control electronic ballasts<br />
and/or <strong>Hager</strong> dimmers<br />
EV100/EV102. Detector especially<br />
dedicated for energy saving<br />
and comfort purpose.<br />
Input for slave (EE810) and/or<br />
derogation pushbutton in order<br />
to modify the setpoints<br />
Lux level, On delay for light<br />
channel and min level via potentiometers<br />
3 functional modes :<br />
no regulation, regulation with<br />
local setpoint, regulation with<br />
remote setpoint<br />
EE813 : accessory to surface<br />
mounting<br />
For technical details<br />
see page 405<br />
Designation Characteristics Width in I Pack Cat.<br />
17.5mm qty. ref.<br />
Presence detector<br />
230V~ 50Hz<br />
1 channel µ16A AC1 - 1 EE810<br />
• relay output light channel<br />
- lux level and on delay triac output 0.8A<br />
(duration or pulse) defined via<br />
potentiometers<br />
• Slave output for association<br />
with EE811/EE812<br />
Lux OFF<br />
EE810<br />
Presence detector<br />
230V~ 50Hz<br />
2 channels µ16A AC1 - 1 EE811<br />
• Relay output light channel<br />
- lux level and On delay 230V input 50Hz<br />
define via potentiometers<br />
- input slave / derogation<br />
- 230V input used with pushbutton<br />
to toggle the light channel<br />
state or with slave in order to<br />
enlarge the detection area<br />
• Relay output presence channel<br />
- on delay presence defined via<br />
potentiometer<br />
µ2 A AC1<br />
EE812<br />
EE813<br />
Presence detector 1/10V 230V~ 50Hz - 1 EE812<br />
• Relay output used to switch µ10 A AC1<br />
ON/OFF the electronic ballast<br />
• 1/10V output used to control an 1/10V 50mA<br />
electronic ballast or <strong>Hager</strong><br />
dimmers EV100/EV102<br />
• 230V input used with push- 230V input 50Hz<br />
button to toggle the channel<br />
or change the setpoint or with<br />
slave in order to enlarge the<br />
detection area<br />
• 3 functional modes defined via<br />
potentiometers<br />
mode 1 : no regulation<br />
mode 2 : regulation with local setpoint<br />
via potentiometer<br />
mode 3 : regulation with setpoint<br />
defined via a remote push button<br />
Accessory - 1 EE813<br />
mounting accessory for surface mounting<br />
can be used with EE810, EE811, EE812<br />
366
Delay timers<br />
58<br />
44<br />
45<br />
Description<br />
To provide all types of<br />
automatic control i.e. lighting,<br />
ventilation, watering, machine<br />
pre-heating, automatic door and<br />
visual audible indication, cycle<br />
control etc.<br />
Applications<br />
For timing and automation in<br />
domestic and commercial<br />
premises. The input signal can<br />
be via various switching devices<br />
(pushbutton, latching switch,<br />
timeclock etc.) and the timed<br />
output used to control the<br />
application.<br />
Technical data<br />
Voltage range :<br />
12 & 24 to 48V DC<br />
12 & 24 to 230V AC<br />
Adjustable: time delay from 0.1s<br />
to 10 hours.<br />
LED indicator<br />
complies with EN 60669-2-1<br />
Connection capacity :<br />
6mm 2 max flexible<br />
1.5 - 10mm 2 rigid<br />
For technical details<br />
see pages 409<br />
<strong>Modular</strong><br />
devices<br />
Designation Characteristics Width in I Pack Cat.<br />
17.5mm qty. ref.<br />
Delay ON 1 c/o contact 1 1 EZ001<br />
10A / 230V~ AC1<br />
Eingang<br />
time delay T : 0.1s to 10hr<br />
Ausgang<br />
T<br />
EZ001<br />
1 Delay OFF 1 c/o contact 1 1 EZ002<br />
10A / 230V~ AC1<br />
Eingang<br />
time delay T : 0.1s to 10hr<br />
Ausgang<br />
T<br />
Adjustable time ON 1 c/o contact 1 1 EZ003<br />
10A / 230V~ AC1<br />
Eingang<br />
time delay T : 0.1s to 10hr<br />
Ausgang<br />
T<br />
EZ003<br />
Timer 1 c/o contact 1 1 EZ004<br />
10A / 230V~ AC1<br />
Eingang<br />
time delay T : 0.1s to 10hr<br />
Ausgang<br />
T<br />
Symmetrical flasher 1 c/o contact 1 1 EZ005<br />
10A / 230V~ AC1<br />
Eingang<br />
time delay T : 0.1s to 10hr<br />
Ausgang<br />
T<br />
EZ006<br />
Multifunction 1 c/o contact 1 1 EZ006<br />
6 individual functions 10A / 230V~ AC1<br />
including :<br />
time delay T : 0.1s to 10hr<br />
D - delay on<br />
C - delay off<br />
E - adjustable time ON<br />
B - adjustalbe time OFF<br />
A - timer<br />
F - symmetrical flasher<br />
- ON<br />
- OFF<br />
367
Time lag switches<br />
Description<br />
EMN001 and EMN005 time lag<br />
switches to provide control of<br />
lighting circuits with automatic<br />
switch-off after a pre-set time.<br />
(e.g. for staircase, corridors<br />
lighting).<br />
The units are of compact with a<br />
2 position switch for permanent/<br />
timed lighting implementation<br />
facility.<br />
1 EMN 005 and EMS 005 incorporate<br />
a pre-warning of switch<br />
OFF to improve the safety for<br />
users and a double delay function<br />
: 30 sec. to 10 min. or 1<br />
hour by pressing the push- button<br />
more than 3s<br />
For technical details<br />
see pages 411<br />
Description Characteristics Width in I Pack Cat.<br />
17.5mm qty. ref.<br />
EMN001<br />
Basic staircase time lag switch voltage rating : 230V 50/60Hz 1 6 EMN001<br />
adjustable time delay setting:<br />
30 seconds until 10 minutes<br />
retrigger<br />
16A - 230V AC1<br />
2300 W incandescent<br />
1500 W halogen VLV<br />
10A - 1000 W compact fluorescent<br />
1000 W Fluo mono/duo<br />
460 W Fluo compact<br />
Multifunction stair case voltage rating : 230V 50/60Hz 2 1 EMN005<br />
time lag switch<br />
- basic stair case time lag switch<br />
- pre-warning mode<br />
- double delay mode<br />
30 sec. to 10 min. or 1 hr.<br />
- double delay with pre-warning mode<br />
16A - 230V AC1<br />
2300 W incandescent<br />
1500 W halogen VLV<br />
1000 W Fluo mono/duo<br />
460 W Fluo compact<br />
368
Emergency lighting module<br />
Application :<br />
for residential and commercial<br />
premises.<br />
Installed in a consumer unit or<br />
distribution board, the lamp can<br />
be configured to light<br />
automatically in the event of<br />
power failure.<br />
It can also be withdrawn from its<br />
base, thereby acting as a mini<br />
torch with an operating duration<br />
of 1 hour 30min.<br />
For technical information<br />
see page 412<br />
Designation Width in I Pack Cat.<br />
17.5mm qty. ref.<br />
<strong>Modular</strong><br />
devices<br />
Emergency lighting module 3 1 EE960<br />
EE960<br />
Remote control for emergency light blocks<br />
The remote control device<br />
switches self contained emergency<br />
lighting into neutral position<br />
or into working position.<br />
It permits each day after closing<br />
down of premises, to switch off<br />
self contained emergency lighting<br />
to avoid the discharge of<br />
battery.<br />
The remote control is<br />
recommended in premises for<br />
public and in industrial or<br />
commercial premises.<br />
The device is a 2 position changeover<br />
switch, with automatic<br />
recall for switching off or on, of<br />
self contained emergency lighting,<br />
by delivering polarized current<br />
impulses on the remote<br />
control circuits (+ or -)<br />
Connection capacity :<br />
6 flexible wire<br />
10 rigid wire<br />
For technical information<br />
see page 412<br />
Designation Characteristics Width in I Pack Cat.<br />
17.5mm qty. ref.<br />
Remote control<br />
to control up to 60 self<br />
contained,<br />
with an average consumption of<br />
0,1 mA / 6 V<br />
power supply :<br />
230 V 50/60 Hz<br />
output supply : 8,4 V ...<br />
time delay for power supply :<br />
24 hours before activation of<br />
remote control<br />
4 1<br />
EE905<br />
Remote control<br />
to control up to 120 self<br />
contained,<br />
with an average consumption of<br />
0,1 mA / 6 V<br />
power supply :<br />
230 V 50/60 Hz<br />
output supply : 12 V ...<br />
time delay for power supply :<br />
24 hours before activation of<br />
remote control<br />
4 1 EE910<br />
EE910<br />
369
Dimmers<br />
range overview<br />
functioning as a standalone product<br />
0W 20W 60W 100W 300W 600W 1000W<br />
functioning in system : association of dimmers<br />
with 1/10V max 30 x 1kW<br />
Incandescent/halogen 230V<br />
EV 011, EV 012<br />
EV 002, EV 004<br />
EV 100, EV 102 switch to “local” position<br />
EV 102 pilot : switch to “master” position<br />
EV 102 + n x EV 100 or EV 102 (slave position)<br />
Halogen VLV (12 or 24V) ferromagnetic<br />
transformer suitable<br />
for dimming.<br />
The transformer shouldn’t be used<br />
with less than 75% of nominal load<br />
Halogen VLV (12 or 24V) via electronic<br />
transformer<br />
EV 011<br />
EV 002, EV 004<br />
EV 100, EV 102 switch to “local” position<br />
EV 012<br />
EV 002, EV 004<br />
EV 100, EV 102 switch to “local” position<br />
EV 102 pilot : switch to “master” position<br />
EV 102 + n x EV 100 or EV 102 (slave position)<br />
EV 102 pilot : switch to “master” position<br />
EV 102 + n x EV 100 or EV 102 (slave position)<br />
1/10V control (output only)<br />
fluo with electroballast 1/10V<br />
Input 1/10 V, 50 mA<br />
EV 106<br />
EV 108 with scene inputs<br />
300 W 600 W 1000 W Pilot 1/10 V<br />
Technical features<br />
EV 011<br />
EV 012<br />
EV 002<br />
EV 004<br />
EV 100 EV 102 EV 106 EV 108<br />
Controls available<br />
- on the product<br />
- external with illuminated pushbutton<br />
- input 1/10 V<br />
- ambient lighting setting<br />
-<br />
yes<br />
-<br />
-<br />
yes<br />
yes<br />
-<br />
1 (EV 004)<br />
yes<br />
yes<br />
yes (slave)<br />
-<br />
yes<br />
yes<br />
yes (slave)<br />
2 levels<br />
yes<br />
yes<br />
-<br />
-<br />
yes<br />
yes<br />
-<br />
2 levels<br />
Types of outputs :<br />
- direct (capacitive/inductive load)<br />
- input 1/10 V<br />
yes<br />
-<br />
yes<br />
-<br />
yes<br />
-<br />
yes<br />
yes (master)<br />
-<br />
yes<br />
-<br />
yes<br />
Functions :<br />
- protection overheating / overloads<br />
- level indicator<br />
- memorisation<br />
- softstart<br />
yes *<br />
-<br />
yes<br />
yes<br />
yes<br />
EV 004<br />
yes<br />
yes<br />
yes<br />
-<br />
yes<br />
yes<br />
yes<br />
yes<br />
yes<br />
yes<br />
yes<br />
yes<br />
yes<br />
-<br />
yes<br />
yes<br />
yes<br />
-<br />
Parameter setting :<br />
- mini, max. level<br />
- dimming speed<br />
- speed at start / stop<br />
- transition speed for level call<br />
-<br />
-<br />
-<br />
-<br />
EV 004<br />
EV 004<br />
EV 004<br />
-<br />
yes<br />
-<br />
-<br />
-<br />
yes<br />
yes<br />
yes<br />
yes<br />
yes<br />
yes<br />
yes<br />
yes<br />
yes<br />
yes<br />
yes<br />
yes<br />
* EV 011 : protection via integrated fuse, electronic protection for other products<br />
dimmers 300 W<br />
universal dimmers 600 W<br />
system dimmers<br />
universal dimmers 1000 W<br />
system dimmers<br />
1-10 V pilots<br />
EV 011 EV 012<br />
EV 002 EV 004<br />
EV 100 EV 102<br />
EV 106 EV 108<br />
370
Dimmers<br />
The <strong>Hager</strong> products are suitable<br />
for all light sources : incandescent,<br />
LV and VLV halogen, fluorescent<br />
with electronic ballast.<br />
Dimming controlled by<br />
push button :<br />
- start/stop by short press<br />
- increasing/decreasing by maintaining<br />
pressure<br />
Common characteristics :<br />
- Softstart (progressive start) to<br />
increase the working live of<br />
lamps<br />
- memorisation of last dimming<br />
level<br />
- protection against overheating<br />
- control possible by illuminated<br />
pushbutton until 5mA.<br />
Dimmer<br />
300 W :<br />
- control by several pushbuttons<br />
- can replace a latching relay<br />
with dimming function<br />
Dimmers 600 and 1000 W :<br />
- universal products with<br />
automatic recognition of the<br />
load<br />
type (inductive/capacitive)<br />
- electronic protection against<br />
overheating and overload<br />
- Indicators :<br />
230 V / overheating / overload<br />
For technical details<br />
see page 413<br />
<strong>Modular</strong><br />
devices<br />
Designation Characteristics Width in ❚ Pack Ref.<br />
17,5 mm qty<br />
Dimmers 300 W<br />
for :<br />
- incandescent 230 V<br />
- halogen 230 V<br />
- VLV halogen lamps with :<br />
• ferromagnetic transformer<br />
(inductive load EV 011 )<br />
• dimmable electronic transformer<br />
(capacitive load (EV 012 )<br />
20 ... 300 W / VA<br />
230 V / 50 Hz<br />
inductive load<br />
capacitive load<br />
1<br />
1<br />
1<br />
1<br />
EV011<br />
EV012<br />
EV011<br />
Universal remote control dimmer<br />
600 W<br />
for :<br />
- incandescent 230 V<br />
- halogen 230 V<br />
- VLV halogen lamps supplied by<br />
ferromagnetic or dimmable electronic<br />
transformer<br />
(cos ≥ 0,95)<br />
20 ... 600 W / VA<br />
230 V / 50 Hz<br />
- products with automatic load<br />
recognition<br />
- dimming function<br />
4 1<br />
EV002<br />
Enhanced universal dimmer<br />
600 W<br />
in addition to EV 002 features :<br />
- min/max level setting<br />
- recall mode with pushbutton,<br />
override mode with switch<br />
- scene level setting<br />
0 ... 99 %<br />
4 1<br />
EV004<br />
EV004<br />
371
Dimmers<br />
For technical details see<br />
pages 413-415<br />
Designation Characteristics Width in ❚ Pack Ref.<br />
17.5 mm qty<br />
EV100<br />
Universal dimmer 1000 W for :<br />
• Functional mode selection via<br />
local switch :<br />
- control via pushbutton (local)<br />
- remote control via 1/10V (slave)<br />
• Min/Max setting via potentiometer<br />
• LED indication :<br />
- 230V power supply/load error<br />
- overload / overheating<br />
Load type :<br />
- incandescent<br />
- 230V halogen lamps<br />
- VLV halogen lamps associated<br />
to ferromagnetic transformer<br />
(inductive)<br />
- VLV halogen lamps associated<br />
to electronic transformer (capacitive)<br />
230 V / 50 Hz<br />
20 ...1 000W<br />
1/10V-input<br />
5 1<br />
EV100<br />
EV102<br />
Universal dimmer 1000 W with<br />
scene inputs<br />
• Functional mode selection via<br />
local switch :<br />
- control via pushbutton (local)<br />
- remote control via 1/10V (slave)<br />
- control of the other dimmers via<br />
1/10V (master)<br />
• Display to show the dim level<br />
and to set the parameters:<br />
- dimming rise time (4s ..99s)<br />
- min dim level (0...49%)<br />
- max dim level (51..99%)<br />
- rise time when switching ON<br />
(1s..99s)<br />
- fall time when switching OFF<br />
(1s..99s)<br />
- scene level<br />
- dimming rise time for each scene<br />
- scene working mode :<br />
recall or override mode<br />
• Output contact to display the<br />
dim state (load is OFF, contact is<br />
opened, if load is dimmed the<br />
contact is closed)<br />
• LED indication :<br />
- 230V power supply / load error<br />
- overload / overheating<br />
Load type :<br />
- incandescent<br />
- 230V halogen lamps<br />
- VLV halogen lamps associated to<br />
ferromagnetic transformer (inductive)<br />
- VLV halogen lamps associated to<br />
electronic transformer (capacitive)<br />
230 V / 50 Hz<br />
20 ...1 000W<br />
1/10V-input/output<br />
(max. 50mA, 30 EV100 / EV102)<br />
defined via the local switch<br />
Contact output :<br />
1 NO, 250V , µ 5A<br />
5 1 EV102<br />
372
Dimmer system: 1/10V pilots<br />
EV 106 and EV 108 pilot<br />
dimmers<br />
• To control several dimmers or<br />
electronic ballasts via the 1/10V<br />
output<br />
• Display to show the dim level<br />
and for parameter setting<br />
• Wiring of illuminated<br />
pushbuttons possible up to<br />
5mA<br />
• Min/max level setting<br />
• Contact output for state<br />
information<br />
• Dimming rise time setting<br />
• Setting of rise time and fall<br />
time<br />
EV 108 pilot dimmer<br />
• Scene inputs used for override<br />
(3 levels) or simple recall<br />
(2 levels).<br />
Use :<br />
to control lighting in meeting and<br />
conference rooms, or in restaurants<br />
Dimmers conform to standards :<br />
EN 50081-1, EN 50082-1,<br />
CEI 669-1, CEI 669-2-1.<br />
For technical details<br />
see page 413<br />
Designation<br />
Characteristics<br />
Width in ❚<br />
17.5 mm<br />
Pack<br />
qty<br />
Ref<br />
<strong>Modular</strong><br />
devices<br />
1/10V pilot dimmer<br />
230 V / 50 Hz<br />
4 1<br />
EV106<br />
EV106<br />
• To control<br />
EV 100 and EV 102 (max. 30)<br />
• To dim electronic ballasts<br />
• Wiring of illuminated<br />
pushbuttons possible up to<br />
5mA<br />
• Display to show the dim level<br />
and to set the parameters:<br />
- dimming rise time (4 s ..99s)<br />
- min dim level (0..49%)<br />
- max. dim level (51..99%)<br />
Contact output to display the<br />
dim state (load is OFF, contact is<br />
opened, if load is dimmed the<br />
contact is closed). It is used to<br />
switch ON/OFF the electronic<br />
ballast<br />
1/10V - interface<br />
Output /max 50mA<br />
contact output :<br />
1 NO, 250 V µ10 A<br />
1/10V pilot dimmer with scene<br />
input<br />
4 1<br />
EV108<br />
EV108<br />
In addition to EV106 features :<br />
• Scene inputs used for override<br />
(3 levels) or simple recall (2)<br />
• For each scene<br />
- dimming rise time<br />
- scene level<br />
- and scene mode<br />
(recall or- override)<br />
373
Switch disconnectors<br />
44<br />
68<br />
45<br />
Description<br />
For use a switch as a<br />
disconnector in all types of<br />
circuit.<br />
Complies with : EN 60 947-3 all<br />
ratings<br />
Technical data<br />
utilisation category<br />
AC 22B<br />
In : 16, 25, 32A<br />
shrouded cable clamps<br />
connection capacity:<br />
16mm 2 rigid conductor<br />
10mm 2 flexible conductor<br />
In : 40, 63, (1 pole)<br />
cable clamps,<br />
connection capacity:<br />
25mm 2 rigid conductor<br />
16mm 2 flexible conductor<br />
In : 80A, 100A<br />
cable clamps<br />
connection capacity:<br />
50mm 2 rigid conductor<br />
35mm 2 flexible conductor<br />
All switches have a green / red<br />
indication on the handle giving<br />
positive contact indication<br />
use MZN175 as locking device<br />
Designation Characteristics Width in I Pack Cat.<br />
17.5mm qty. ref.<br />
SB140<br />
Single pole 1 x 16A 250V~ 1 12 SB116<br />
1 x 16A 250V~ 1 1 SB116V<br />
with pilot light<br />
1 x 25A 250V~ 1 12 SB125<br />
1 x 25A 250V~ 1 1 SB125V<br />
with pilot light<br />
1 x 32A 250V~ 1 1 SB132<br />
1 x 32A 250V~ 1 1 SB132V<br />
with pilot light<br />
1 x 40A 250V~ 1 1 SB140<br />
1 x 63A 250V~ 1 1 SB163<br />
1 x 80A 250V~ 1 1 SB180<br />
1 x 100A 250V~ 1 1 SB199<br />
SB232<br />
SB240<br />
Double pole 2 x 16A 250V~ 1 12 SB216<br />
2 x 16A 250V~ 1 1 SB216V<br />
with pilot light<br />
2 x 25A 250V~ 1 12 SB225<br />
2 x 25A 250V~ 1 1 SB225V<br />
with pilot light<br />
2 x 32A 250V~ 1 1 SB232<br />
2 x 32A 250V~ 1 1 SB232V<br />
with pilot light<br />
2 x 40A 250V~ 1 1 SB240<br />
2 x 63A 250V~ 1 6 SB263<br />
2 x 80A 250V~ 1 1 SB280<br />
2 x 100A 250V~ 1 1 SB299<br />
Triple pole 3 x 16A 400V~ 2 1 SB316<br />
3 x 25A 400V~ 2 1 SB325<br />
3 x 32A 400V~ 2 1 SB332<br />
3 x 32A 400V~ 3 1 SB332Q<br />
large terminals<br />
3 x 40A 400V~ 3 1 SB340<br />
3 x 63A 400V~ 3 1 SB363<br />
3 x 80A 400V~ 3 1 SB380<br />
3 x 100A 400V~ 3 1 SB399<br />
SB363<br />
Designation Characteristics Width in I Pack Cat. ref. Cat. ref.<br />
17.5mm qty. neutral neutral<br />
left<br />
right<br />
Four pole<br />
4 x 16A 400V~ 2 1 SB416F SB416<br />
4 x 25A 400V~ 2 1 SB425F SB425<br />
4 x 32A 400V~ 2 1 SB432F SB432<br />
4 x 40A 400V~ 4 1 SB440F SB440<br />
4 x 63A 400V~ 4 1 SB463F SB463<br />
4 x 80A 400V~ 4 1 SB480F SB480<br />
4 x 100A 400V~ 4 1 SB499F SB499<br />
374
Trip free switches<br />
Type SA<br />
Free tripping disconnector<br />
switch<br />
Allows remote control* tripping<br />
via voltmetric tripping relay to<br />
associate on the left side of<br />
product<br />
associated auxiliary : auxiliary<br />
contact (AC).<br />
For the main protection in<br />
general or sub-switchboard<br />
* emergency stop<br />
Connection capacity for switch :<br />
- 6 to 16 flexible<br />
- 6 to 25 rigid<br />
associated auxiliary :<br />
- 0,5 to 6 flexible<br />
- 1 to 10 rigid<br />
Complies with :<br />
IEC 947-1 and 947-3<br />
AC 23 A<br />
For technical details<br />
see page 420<br />
Designation Characteristics Width in ❚<br />
17,5 mm<br />
Pack<br />
qty<br />
Ref.<br />
2 pole switches 2 x 40 A 250 V <br />
2,5<br />
2 x 63 A 250 V <br />
2,5<br />
1<br />
1<br />
SA240<br />
SA263<br />
<strong>Modular</strong><br />
devices<br />
Ui = 690 V<br />
2 x 80 A 250 V <br />
2,5<br />
1<br />
SA280<br />
4 pole switches 4 x 40 A 400 V <br />
4,5<br />
1<br />
SA440<br />
SA263<br />
4 x 63 A 400 V <br />
4,5<br />
1<br />
SA463<br />
Ui = 690 V<br />
4 x 80 A 400 V <br />
4,5<br />
1<br />
SA480<br />
Shunt trip<br />
allows remote tripping<br />
of the trip free switch.<br />
230 - 415V~ 1 1 MZ203<br />
110 - 130V=<br />
24 - 48V~ 1 1 MZ204<br />
12 - 48V=<br />
MZ203<br />
Under voltage release<br />
allows trip free switch to be<br />
closed only when voltage is<br />
above 70% of Un. trip free<br />
switch will automatically trip<br />
when voltage falls by 35% of Un<br />
48V = 1 1 MZ205<br />
230V ~ 1 1 MZ206<br />
MZ206<br />
375
2 way / centre - off changeover modular switches<br />
Designation Characteristics Width in I Pack Cat.<br />
17.5mm qty. ref.<br />
Switch, 2 ways<br />
single pole<br />
1 x 25A 250V~ 1 12 SF118F<br />
1<br />
2 4<br />
Double pole<br />
2 x 25A 250V~ 1 12 SF115<br />
1<br />
3<br />
SF118F<br />
2 4<br />
Double pole<br />
2 x 25A 250V~ 2 6 SF218F<br />
1<br />
5<br />
2 4<br />
6 8<br />
SF219F<br />
Switches<br />
centre - off changeover<br />
single pole<br />
1<br />
1 x 25A 250V~ 1 12 SF119F<br />
1 x 40A 250V~ 1 12 SF119G<br />
2 4<br />
double pole<br />
1<br />
5<br />
2 4 6 8<br />
2 x 25A 250V~ 2 6 SF219F<br />
2 x 40A 250V~ 2 6 SF219G<br />
3 x 40A 250V~ 3 4 SF319G<br />
4 x 40A 250V~ 4 3 SF419G<br />
SZ010<br />
Handle link pin<br />
for switch handles<br />
1 set includes 1 set SZ010<br />
5 pins 2 mod width<br />
5 pins 3 mod width<br />
5 pins 4 mod width<br />
376
Pushbuttons<br />
Description<br />
To actuate loads either directly<br />
or via contactors etc.<br />
Technical data<br />
<strong>Modular</strong> pushbuttons :<br />
- without light<br />
with grey button, red/green<br />
optional<br />
- with light<br />
with red, green button (amber,<br />
blue, colourless, red, green lenses<br />
on option).<br />
delivered with lamp 230V~, E10<br />
cap.<br />
Options<br />
Pushbuttons can be fitted with<br />
12, 24, 48, 60V lamps (see<br />
below).<br />
Connection capacity :<br />
Shrouded cable clamp type<br />
10▫ rigid conductor<br />
6▫ flexible conductor<br />
<strong>Modular</strong><br />
devices<br />
Designation Characteristics Width in I Pack Cat.<br />
17.5mm qty. ref.<br />
Pushbuttons<br />
without indicator light<br />
impulse 16A - 250V~<br />
contact : 1NO 1 12 SV021<br />
contacts : 2NO 1 12 SV022<br />
contacts : 3NO 1 12 SV025<br />
SV025<br />
contact : 1NC 1 12 SV023<br />
contacts : 2NC 1 12 SV024<br />
contacts : 1NO / 1NC 1 12 SV120<br />
contacts : 1NO+1NC 1 12 SV031<br />
contacts : 2 changeovers 1 12 SV026<br />
SV031<br />
Pushbuttons<br />
impulse<br />
with indicator light<br />
contact: 1NO green 1 12 SV124<br />
contacts: 2 NO red 1 12 SV062<br />
contact: 1 NC red 1 12 SV123<br />
contacts: 2 NC green 1 12 SV064<br />
SV062<br />
377
Pushbuttons (Latching)<br />
Designation Characteristics Width in I Pack Cat.<br />
17.5mm qty. ref.<br />
Pushbuttons<br />
without indicator light<br />
latching 16A - 250V~<br />
contact : 1NO 1 12 SV041<br />
contacts : 2NO 1 12 SV042<br />
contacts : 3NO 1 12 SV047<br />
contacts : 4NO 1 12 SV048<br />
contacts : 1NO+1NC 1 12 SV045<br />
contacts : 2 changeovers 1 12 SV046<br />
Pushbuttons<br />
latching<br />
with indicator light<br />
contact : 1NO green 1 12 SV071<br />
contacts : 2NO green 1 12 SV072<br />
SV072<br />
Indicator lights<br />
38<br />
62<br />
Description<br />
<strong>Modular</strong> indicator lights<br />
Available with red, green,<br />
amber, blue, colourless lens<br />
Delivered with lamp 230V~,<br />
E10 cap.<br />
Options<br />
Indicator lights can be fitted with<br />
12, 24, 48, 60V lamps (see<br />
below).<br />
shrouded cable clamp type<br />
Connection capacity:<br />
10▫ rigid conductor.<br />
6▫ flexible conductor.<br />
45<br />
Designation Characteristics Width in I Pack Cat.<br />
17.5mm qty. ref.<br />
Indicator green lens 1 12 SVN121<br />
lights<br />
with light 230V~ red lens 1 12 SVN122<br />
230 V~<br />
orange lens 1 12 SVN123<br />
clear lens 1 12 SVN124<br />
blue lens 1 12 SVN125<br />
red & green double indicator 1 12 SVN126<br />
red triple indicator 1 12 SVN127<br />
378
Auxiliaries for pushbuttons and indicator lights ...<br />
38<br />
67<br />
45<br />
Description<br />
This system makes it possible to<br />
build a large range of<br />
pushbuttons and indicator<br />
lamps.<br />
Pushbuttons are built using :<br />
- a base<br />
- the contents<br />
- the lamps<br />
A choice of 6 auxiliary contacts<br />
are available.<br />
The lamp can be selected as<br />
needed.<br />
Indicator lamps :<br />
- the base<br />
- a choice of 5<br />
colours<br />
- 12-230V<br />
Auxiliaries with flashing or test<br />
lamp facility.<br />
Characteristics :<br />
pushbuttons<br />
- 16A AC21 230V~<br />
lamps<br />
12, 24, 48, 60V~ - 0.9W<br />
230V~ neon 0.5W<br />
230V~ fluorescent 0.6W<br />
use fluorescent lamp with blue<br />
and green lenses.<br />
Connection capacity:<br />
10▫ rigid conductor.<br />
6▫ flexible conductor.<br />
<strong>Modular</strong><br />
devices<br />
Designation Characteristics Width in I Pack Cat.<br />
17.5mm qty. ref.<br />
Supports<br />
for single pushbutton (impulse) 1 6 SW020<br />
(latching) 1 6 SW040<br />
SW020<br />
SW030<br />
for double pushbutton 1 6 SW030<br />
1 6 SW050<br />
+<br />
1 6 SW090<br />
for single pushbutton 1 6 SW060<br />
and indicator<br />
1 6 SW070<br />
for indicator lights 1 6 SW080<br />
SW070<br />
SW080<br />
Electrical auxiliaries 16A - 250V~<br />
for pushbuttons<br />
contact : 1NO 12 SW007<br />
contacts : 2NO 12 SW002<br />
SW007<br />
SW002<br />
contact : 1NC 12 SW003<br />
contacts : 2NC 12 SW004<br />
contact : 1 changeover 12 SW006<br />
contacts : 1NO+1NC 12 SW005<br />
SW003<br />
SW005<br />
379
Auxiliaries for pushbuttons and indicator lights<br />
Designation Characteristics Pack Cat.<br />
qty.<br />
ref.<br />
Electrical auxiliaries<br />
for indicator lights<br />
test lamp to test a serie of indicator lights 6 SW112<br />
on the same phase<br />
for signal application for one or several indicator lights 6 SW113<br />
SW112<br />
SW113<br />
End plate 12 SW009<br />
for pushbuttons<br />
SW009<br />
SW081 SW082 SW083<br />
Lenses green 12 SW081<br />
for pushbuttons and<br />
indicator lights red 12 SW082<br />
SW084<br />
SW085<br />
orange 12 SW083<br />
clear 12 SW084<br />
blue 12 SW085<br />
SW104<br />
Lamps E10 neon 230V~ 0.5W 20 SW104<br />
for pushbuttons and<br />
indicator lights fluorescent 230V~ 0.6W 20 SW103<br />
incandescent 12V~ 0.9W 20 SW105<br />
24V~ 0.9W 20 SW102<br />
48 & 60V~ 0.9W 20 SW107<br />
SW015 SW016 SW019<br />
Interchangeable (impulse) grey 12 SW017<br />
pushbuttons covers<br />
(latching) grey 12 SW018<br />
SW017<br />
SW018<br />
green 12 SW015<br />
red 12 SW016<br />
clear 12 SW019<br />
380
Transformers, bells and buzzers<br />
58<br />
44<br />
45<br />
Description<br />
Provide extra safety low voltage<br />
8, 12, 24V~.<br />
Technical data<br />
Secondary voltages:<br />
8, 12, 24V~<br />
Bell transformers are<br />
short-circuit protected.<br />
Bells/buzzers:<br />
Max. continuous duty<br />
≤ 30 minutes.<br />
Connection capacities : 6▫<br />
Cable clamp type<br />
Output:<br />
Bells: 85 dBA<br />
Buzzers: 78 dBA<br />
When a bell transformer is<br />
installed in an enclosure with<br />
mains voltage equipment, 230V<br />
cable should be used on the<br />
secondary side of the<br />
transformer or extra low voltage<br />
cable should be sheathed within<br />
the enclosure.<br />
Note:<br />
the transformers have a<br />
higher no load voltage.<br />
The stated voltages<br />
correspond to the<br />
voltages on nominal<br />
load.<br />
For technical details<br />
see page 421<br />
<strong>Modular</strong><br />
devices<br />
Designation Characteristics Width in I Pack Cat.<br />
17.5mm qty. ref.<br />
Safety transformers 16VA 50/60Hz 4 1 ST313<br />
230V 12-24V~ 25VA 50/60Hz 4 1 ST312<br />
50/60Hz<br />
40VA 50/60Hz 4 1 ST314<br />
63VA 50/60Hz 6 2 ST315<br />
ST313<br />
Bell transformers 230V/8-12V~ 50/60Hz 2 6 ST301<br />
4VA - 8-12V : 0.33A<br />
230V/8-12V~ 50/60Hz 2 6 ST303<br />
8VA - 8V : 1A<br />
12V : 0.67A<br />
230V/8-12V~ 50/60Hz 3 1 ST305<br />
16VA - 8V : 2A<br />
12V : 1.33A<br />
24V : 0.67A<br />
ST301<br />
Bells 8/12V~ 1 12 SU212<br />
5VA - 0.33A<br />
230V~ 1 12 SU213<br />
6.5VA - 0.03A<br />
SU212<br />
Buzzers 8/12V~ 1 12 SU214<br />
4VA - 0.35A<br />
230V~ 1 12 SU215<br />
6.5VA - 0.03A<br />
SU214<br />
381
Analogue voltmeters, ammeters<br />
Analogue voltmeters<br />
For domestic and commercial<br />
installations<br />
single phase :<br />
direct connection<br />
three phase :<br />
use of a voltmeter selector<br />
switch SK 602 - see page 38<br />
Frequency : 50/60Hz<br />
Analogue ammeters<br />
For domestic and commercial<br />
installations<br />
Direct reading :<br />
up to 30A<br />
Indirect reading via current<br />
transformers - see page 36<br />
from 50 to 2000A<br />
Connection capacity :<br />
Rigid conductor 10▫<br />
Flexible conductor 6▫<br />
For technical details,<br />
see page 422<br />
Designation Characteristics Width in I Pack Cat.<br />
17.5mm qty. ref.<br />
Voltmeter accuracy : 2% 4 1 SM500<br />
consumption : 2.5VA<br />
0 - 500V<br />
SM500<br />
Analog ammeters 0 - 5A 4 1 SM005<br />
direct<br />
0 - 15A 4 1 SM015<br />
0 - 30A 4 1 SM030<br />
SM030<br />
Ammeters accuracy : 2%<br />
current transformer (CT)<br />
operated<br />
- reading via CT SR 051 scale : 0 - 50A 4 1 SM050<br />
- reading via CT SR 101 scale : 0 - 100A 4 1 SM100<br />
- reading via CT SR 150 scale : 0 - 150A 4 1 SM150<br />
- reading via CT SR 250 scale : 0 - 250A 4 1 SM250<br />
- reading via CT SR 400 scale : 0 - 400A 4 1 SM400<br />
- reading via CT SR 600 scale : 0 - 600A 4 1 SM600<br />
- reading via CT SR 800 scale : 0 - 800A 4 1 SM800<br />
- reading via CT SR 850 scale : 0 - 1000A 4 1 SM850<br />
- reading via CT SR 900 scale : 0 - 1500A 4 1 SM900<br />
- reading via CT SR 910 scale : 0 - 2000A 4 1 SM910<br />
382
Digital voltmeters, ammeters<br />
Digital voltmeters<br />
SM501<br />
For domestic and commercial<br />
installations.<br />
three phase :<br />
use of a voltmeter selector<br />
switch SK 602<br />
Digital ammeters<br />
from SM 020 to SM 911<br />
SM 020 : direct reading<br />
from SM 151 to SM 911 :<br />
reading via a current transformer<br />
(see below)<br />
For technical details,<br />
see page 422<br />
Designation Characteristics Width in I Pack Cat.<br />
17.5mm qty. ref.<br />
Digital voltmeter voltage rating :<br />
220/230V; 50/60Hz<br />
accuracy : ±1%<br />
consumption : 4VA<br />
scale : 0 -500V 4 1 SM501<br />
<strong>Modular</strong><br />
devices<br />
SM501<br />
Digital ammeters voltage rating :<br />
220/230V; 50/60Hz<br />
accuracy : ±1%<br />
consumption : 4VA<br />
- direct scale : 0-20A 4 1 SM020<br />
- reading via CT150/5A scale : 0-150A 4 1 SM151<br />
(SR 150)<br />
- reading via CT 400/5A scale : 0-400A 4 1 SM401<br />
(SR 400)<br />
- reading via CT 600/5A scale : 0-600A 4 1 SM601<br />
(SR 600)<br />
SM020<br />
- reading via CT 800/5A scale : 0-800A 4 1 SM801<br />
(SR 800)<br />
- reading via CT 1500/5A scale : 0-1500A 4 1 SM901<br />
(SR 900)<br />
- reading via CT 2000/5A scale : 0-2000A 4 1 SM911<br />
(SR 910)<br />
383
Digital multimeter<br />
Multimeter<br />
For monitoring the electrical<br />
network : single, two or three<br />
phases (with or without neutral).<br />
Connection on current<br />
transformer (not provided).<br />
Enables to display 3 electrical<br />
values at the same time, in type<br />
instantaneous, average or<br />
maximum (voltage and intensity<br />
per phase in RMS value).<br />
For monitoring of power<br />
generator, it measures the<br />
frequency and working time.<br />
For technical details,<br />
see page 423<br />
Designation<br />
Characteristics<br />
Width in ❚<br />
17.5 mm<br />
Pack<br />
qty<br />
Ref.<br />
Multimeter<br />
- 3 voltmeters : 35 to 480 V<br />
- 3 ammeters per<br />
transformer 0-5 A : 5 to 600 A<br />
- mesure of frequency :<br />
40 to 80 Hz<br />
- hourly metering<br />
4<br />
1 SM001<br />
SM001<br />
384
Current transformers (C.T.)<br />
Description :<br />
Current transformers are used to<br />
feed analogue and digital<br />
ammeters. As well as kWh<br />
meters.<br />
Their current on secondary<br />
circuit (0-5A) is proportional to<br />
the current on primary circuit<br />
class : 1<br />
can be mounted on copper bar<br />
or on cable<br />
can be mounted on DIN rail with<br />
adaptors<br />
For technical details,<br />
see page 424<br />
Designation Characteristics Width in I Pack Cat.<br />
17.5mm qty. ref.<br />
<strong>Modular</strong><br />
devices<br />
Current transformers (CT) ratio :<br />
50/5 2,5 1 SR051<br />
100/5 2,5 1 SR101<br />
SR051<br />
150/5 3,5 1 SR150<br />
200/5 3,5 1 SR200<br />
250/5 3,5 1 SR250<br />
SR200<br />
300/5 4,5 1 SR300<br />
400/5 4,5 1 SR400<br />
600/5 4,5 1 SR600<br />
800/5 5,5 1 SR800<br />
1000/5 6 1 SR850<br />
1500/5 6 1 SR900<br />
2000/5 6 1 SR910<br />
385
Selector switches for voltmeters and ammeters<br />
Description<br />
To provide command signals or<br />
program selection in electrical<br />
control schemes<br />
Application<br />
For domestic and commercial<br />
installations<br />
Connection capacity :<br />
Rigid conductor : 1.5 to 10▫<br />
Flexible conductor : 1 to 6▫<br />
Conform to IEC947-3<br />
BS EN 60947-3<br />
Isolating voltage : 500Vac<br />
Nominal current : 10-20A<br />
Designation Characteristics Width in I Pack Cat.<br />
17.5mm qty. ref.<br />
1 pole selector switch 20A 400V~ 3 1 SK600<br />
non spring return<br />
1 3<br />
0<br />
1 2<br />
2<br />
2 pole selector switch 20A 400V~ 3 1 SK601<br />
0<br />
non spring return<br />
1<br />
3<br />
5 7<br />
1<br />
2<br />
SK600<br />
2<br />
6<br />
Voltmeter selector 20A 400Vac 3 1 SK602<br />
3Ph&N<br />
3 readings between phases<br />
3 readings between phase & neutral<br />
null position (no reading)<br />
SK602<br />
Ammeter selector 20A 400Vac 3 1 SK603<br />
4 positions<br />
use in 3Ph&N<br />
reading by phase<br />
null position (no reading)<br />
should be used with current transformer (CT)<br />
SK603<br />
Step selector switch 20A 400V~ 3 1 SK604<br />
2<br />
3<br />
4<br />
5 3 7<br />
1<br />
1<br />
2<br />
0<br />
Key selector switch 10A 400V~ 3 1 SK606<br />
1<br />
3<br />
0<br />
1<br />
1<br />
2<br />
4<br />
0<br />
SK606<br />
386
Kilowatt hours meters and hours counter ...<br />
57<br />
41<br />
45<br />
Description<br />
Kilowatt hours meters measure<br />
the active energy used in an<br />
electric installation. The range<br />
includes meters with pulsed<br />
output for remote indication or<br />
linking into an energy<br />
management system.<br />
Kwh meters can be used for<br />
local metering of installation or<br />
monitoring of power<br />
consumption in individual<br />
machines.<br />
Technical data<br />
In accordance to IEC1036,<br />
- with pulse output<br />
100Wh/pulse (except EC110 and<br />
EC050)<br />
- all meters offer part (resettable)<br />
counter and total (non<br />
resettable) counter (except<br />
EC110, EC050 and EC051)<br />
- display with LCD<br />
- accuracy : class II (EC050 and<br />
EC051 class I)<br />
- for CT (current transformers),<br />
see page 385<br />
For technical details,<br />
see pages 426<br />
Designation Characteristics Width in I Pack Cat.<br />
17.5mm qty. ref.<br />
Single phase<br />
230V +/- 20% 50/60Hz<br />
<strong>Modular</strong><br />
devices<br />
- direct reading 32A single tariff 3 1 EC110<br />
without pulsed output<br />
1 1 EC050<br />
EC051<br />
single tariff 3 1 EC111<br />
with pulsed output<br />
1 1 EC051<br />
Single phase 230V 50Hz 3 1 EC120<br />
CT operated<br />
100/5A CT operated<br />
single tariff<br />
EC111<br />
230V 50Hz 3 1 EC121<br />
100/5A CT operated<br />
dual tariff<br />
Three phase 230V/400V 50Hz 7 1 EC310<br />
CT operated<br />
800mA to 80A<br />
single tariff<br />
230V/400V 50Hz 7 1 EC311<br />
800mA to 80A<br />
dual tariff<br />
Three phase 230V/400V 50Hz 4 1 EC320<br />
CT operated<br />
50-1500/5A CT operated<br />
single tariff<br />
EC121<br />
230V/400V 50Hz 4 1 EC321<br />
50-1500/5A CT operated<br />
dual tariff<br />
Sealing kit for single phase Kwh meters 1 EC001<br />
direct reading only<br />
(EC 110, EC 111)<br />
Hours counter 230V 50Hz 2 1 EC100<br />
EC100<br />
387
Control relays ...<br />
Control relays are used in installations<br />
where the current or the<br />
voltage fluctuation may damage<br />
equipments.<br />
The range is composed of<br />
modular devices :<br />
Voltage control relays dedicated<br />
to protect air conditioning equipments<br />
:<br />
EU 100, EU 101 single phase<br />
EU 301 three phase<br />
Voltage control relay used to<br />
survey DC or AC voltage :<br />
EU 102 single phase product to<br />
monitor DC or AC<br />
EU 302 three phase control relay<br />
used to check AC voltage<br />
Current control relay used to<br />
survey DC or AC current :<br />
EU 103 single phase product to<br />
monitor DC or AC current direct<br />
via current transformer<br />
Phase control relay<br />
EU 300 to verify phase parameters<br />
(asymmetry, loss of phase,<br />
undervoltage)<br />
The two digital control relays<br />
EU 102 and EU 103 are<br />
equipped with an LCD indicator.<br />
During normal operation, the<br />
LCD displays the measured<br />
voltage (EU 102) or current<br />
(EU 103). The LCD and the local<br />
pushbuttons are also used to<br />
enter the parameter settings<br />
(type of signal, monitored levels,...)<br />
In case of an error, the relay will<br />
close a contact (changeover<br />
contact 8A)<br />
For technical information<br />
see page 429<br />
Designation characteristics Width in I Pack Cat.<br />
17.5mm qty. ref.<br />
Single phase compressor Power supply 230V AC 2 1 EU100<br />
control relay<br />
Under/over voltage control<br />
Umin : 0,75 Un - Umax : 1,2 Un<br />
Restart duration (5 or 10 minutes)<br />
selected via bridge<br />
Output : changeover contact<br />
8A AC1 250V~<br />
EU100<br />
Single phase compressor Power supply 230V AC 2 1 EU101<br />
control relay<br />
Under/over voltage control<br />
Umin/Umax : +/-5% to +/-20% Un<br />
set via potentiometer<br />
Restart duration (5 or 10 minutes)<br />
selected via switch<br />
Output : changeover contact<br />
8A AC1 250V~<br />
Three phase compressor Power supply 400V AC 2 1 EU301<br />
control relay<br />
Under/over voltage control<br />
Umin/Umax : +/-5% to +/-20% Un<br />
set via potentiometer<br />
Restart duration (5 or 10 minutes)<br />
selected via switch<br />
Output : changeover contact<br />
8A AC1 250V~<br />
EU301<br />
Phase control relay Power supply 400V AC 2 1 EU300<br />
Under / over voltage control<br />
Loss of phase, phase order control<br />
Asymetry control : +/-5% to +/-20%<br />
set via potentiometer<br />
Output : changeover contact<br />
8A AC1 250V~<br />
388
... Control relays<br />
Designation characteristics Width in I Pack Cat.<br />
17.5mm qty. ref.<br />
Voltage control relay Power supply 230V~ 2 1 EU102<br />
with LCD<br />
Voltage monitored DC 15 to 700V<br />
or AC 15 to 480V~<br />
Under / over voltage or both<br />
control bands<br />
Parameter setting via pushbutton<br />
and LCD indicator<br />
Output : changeover contact<br />
8A AC1 250V~<br />
EU102<br />
Three phase voltage Power supply Un 400V~ 2 1 EU302<br />
control relay<br />
Under/over voltage control<br />
Umin/Umax : +/-5% to +/-20% Un<br />
set via potentiometer<br />
Output : changeover contact<br />
8A AC1 250V~<br />
<strong>Modular</strong><br />
devices<br />
Current control relay Power supply Un 230V~ 2 1 EU103<br />
single phase with LCD<br />
Current control DC or AC,<br />
direct 0,1A to 10A or via current<br />
transformer<br />
Under / over current or<br />
both control bands<br />
Parameter setting via pushbutton<br />
and LCD indicator<br />
Output : changeover contact<br />
8A AC1 250V~<br />
389