H a r r i n g t o n B e a m A c c e s s o r y K i t s<br />

Provides the convenience of pre-fabricated bracing <strong>and</strong> bridge beam accessories.<br />

• For use with any <strong>Harrington</strong> end truck—specify end truck model when ordering.<br />

• Kit includes: trolley stops; bridge beam to truck bracing; bridge beam mounting plates; angle festoon brackets;<br />

control panel mounting bracket; <strong>and</strong> necessary hardware.<br />

• Fits S <strong>and</strong> W shaped bridge beams—specify bridge beam size <strong>and</strong> crane span when ordering.<br />

See illustrations, facing page.<br />

O p t i o n s a n d A c c e s s o r i e s :<br />

C o n s u l t Fa c t o r y<br />

• Anti kick-up rollers for underhung bridge cranes with cantilevered end(s).<br />

• Special dimensional requirements for end trucks.<br />

• Collector mounting bracket with 1" square bar.<br />

• Special control circuit voltages for control panels.<br />

• Special voltages for end truck drives.<br />

• Underhung end trucks capable of operating on patented track.<br />

18<br />

C o m p l i a n c e<br />

In order to meet requirements of the Crane Manufacturers Association of America (CMAA),<br />

the National Electric Code (NEC) <strong>and</strong> the American National St<strong>and</strong>ards Institute (ANSI/ASME),<br />

<strong>Harrington</strong> components include:<br />

• Thermal motor protection for all motors.<br />

• Rubber bumpers for Series 3 <strong>and</strong> HPC 500 end trucks.<br />

• Rubber bumpers <strong>and</strong> drop stops for motorized trolley hoists.<br />

• <strong>Hoists</strong> load tested to 125% of rated capacity.<br />

• Drop stops for all end trucks.<br />

• Rail sweeps for all end trucks.<br />

• Recommended bridge beams comply with CMAA.


H A R R I N G T O N C R A N E C O M P O N E N T S<br />

<strong>Harrington</strong> beam accessory kits:<br />

Underhung Beam Accessory Kit<br />

19<br />

Top Running Beam Accessory Kit


B r i d g e B e a m S e l e c t i o n C h a r t s<br />

S E R I E S 3 — S I N G L E G I R D E R B E A M S I Z E S<br />

Bridge beam sizing is based on <strong>Harrington</strong> chain hoist products’ weights <strong>and</strong> speeds<br />

Maximum<br />

Allowable<br />

Span<br />

(ft)<br />

Capacity (Tons)<br />

1/2 1 2 3 5 8 10<br />

10 S8x18.4 S8x18.4 S10x25.4 S12x31.8 S12x40.8 W18x71 W21x93<br />

15 S8x18.4 S8x18.4 S10x25.4 S12x40.8 S15x50 W21x83 W18x106<br />

20<br />

20 S8x18.4 S10x25.4 S12x31.8 S15x42.9<br />

25 S10x25.4 S10x25.4<br />

S12x31.8<br />

C8x11.5<br />

30 S10x25.4 S12x31.8 S15x42.9<br />

35 S12x31.8 S15x42.9<br />

40 S15x42.9<br />

45<br />

S15x42.9<br />

C8x11.5<br />

S15x42.9<br />

C8x11.5<br />

S15x42.9<br />

C8x11.5<br />

S15x42.9<br />

C8x11.5<br />

S15x42.9<br />

C10x15.3<br />

S15x42.9<br />

C8x11.5<br />

S15x42.9<br />

C10x15.3<br />

W21x93<br />

W24x103<br />

W18x119<br />

W24x103<br />

C12x20.7<br />

W16x77 W24x103 W27x129<br />

W16x67 W21x83 W27x114 W30x148<br />

W18x60 W18x71 W21x83<br />

W16x57 W18x71 W18x76 W24x94<br />

50 W16x40 W18x60 W18x76 W21x83 W27x102<br />

55 W16x57 W16x67 W21x83 W24x94 W27x114<br />

60 W16x67 W18x76 W21x93 W27x114<br />

Note: Above channel caps are span less 10'0" for overall length.<br />

The beam sizes listed in this chart are for indoor use only. For outdoor applications, consult Customer Service.<br />

W30x116<br />

C15x33.9<br />

W27x114<br />

C12x20.7<br />

W27x114<br />

C15x33.9<br />

W30x124<br />

C15x33.9<br />

W30x132<br />

C15x33.9<br />

W33x141<br />

C15x33.9<br />

W27x129<br />

C15x33.9<br />

W30x148<br />

C15x33.9<br />

W30x148<br />

C15x33.9<br />

W30x148<br />

C15x33.9<br />

W33x169<br />

C15x33.9<br />

H P C R E C O M M E N D E D B R I D G E B E A M S — E L E C T R I C H O I S T<br />

Bridge beam sizing is based on <strong>Harrington</strong> products’ weights <strong>and</strong> speeds<br />

1. Includes 15% allowance for Electric Hoist load factor.<br />

2. Based on <strong>Harrington</strong>’s electric chain hoist product.<br />

3. For spans greater than 10 ft, braces between end truck <strong>and</strong> bridge beam are recommended.<br />

Maximum Allowable Span (ft)<br />

Capacity<br />

(Tons)<br />

10 15 20 24<br />

1/2 S8x18.4 S8x18.4 S8x18.4 S10x25.4<br />

1 S8x18.4 S8x18.4 S10x25.4 S10x25.4<br />

2 S10x25.4 S10x25.4 S12x31.8<br />

S12x31.8<br />

C8x11.5<br />

The beam sizes listed in this chart are for indoor use only. For outdoor applications, consult Customer Service.


H A R R I N G T O N C R A N E C O M P O N E N T S<br />

B r i d g e C r a n e C o n t r o l P a n e l s<br />

All motorized bridge cranes require a master panel to control bridge crane functions. <strong>Harrington</strong> control<br />

panels are completely pre-wired <strong>and</strong> tested, <strong>and</strong> ready to mount on bridge beam. St<strong>and</strong>ard panel is<br />

NEMA 1 rated <strong>and</strong> includes:<br />

Through-the-door fused<br />

disconnect switch is OSHA<br />

compliant lock-out capable<br />

Main line contactor<br />

allows the crane to be turned<br />

on <strong>and</strong> off from the pendant<br />

Reversing contactor<br />

provides bridge crane<br />

forward <strong>and</strong> reverse control<br />

Thermal overload relay<br />

(auto-reset) protects crane<br />

drives from overheating<br />

21<br />

Control transformer<br />

(with primary <strong>and</strong> secondary<br />

fusing) provides low voltage<br />

control circuit for pendant<br />

Fusing for crane drives protects<br />

motors <strong>and</strong> are NEC compliant<br />

Electric Acceleration<br />

Control (EAC) allows easy field<br />

adjustment of crane acceleration<br />

<strong>and</strong> helps minimize load swing<br />

NEMA 4 bridge crane control panels available upon request.


B r i d g e C r a n e C o n t r o l P a n e l s<br />

These panels are for use with all <strong>Harrington</strong> Series 3 motorized end trucks <strong>and</strong> are NEC compliant for<br />

overhead bridge cranes. All panels include bridge mounting bracket <strong>and</strong> wiring diagram. Specify voltage<br />

when ordering.<br />

St<strong>and</strong>ard Panel<br />

22<br />

Single Speed <strong>and</strong> Dual Speed Models with EAC—700, 800, 900 Series<br />

St<strong>and</strong>ard features include:<br />

Lock-out compatible throughthe-door<br />

manual disconnect switch<br />

with system fusing, 110 volt control<br />

circuit transformer with primary<br />

<strong>and</strong> secondary fusing, mainline<br />

contactor, mechanically interlocked<br />

reversing contactor, time <strong>and</strong><br />

torque adjustable Electronic<br />

Acceleration Control (EAC), branch<br />

circuit fusing for bridge, auto-reset<br />

thermal overload relay, <strong>and</strong> bottom<br />

hinged door.<br />

Total System Amps<br />

7 = 24 max.<br />

8 = 48 max.<br />

Total System Amps<br />

9 80 max.<br />

7 = 24 max.<br />

8 = 48 max.<br />

9 = 80 max.<br />

Model<br />

2<br />

Model<br />

2<br />

7 2<br />

7 2<br />

1<br />

1<br />

Product Code<br />

Speed<br />

Blank = Single Speed<br />

D = Dual Speed<br />

Speed<br />

Blank = Single Speed<br />

D = Dual Speed<br />

Enclosure Rating<br />

1 = NEMA 1<br />

4 = NEMA 4<br />

Enclosure Rating<br />

1 = NEMA 1<br />

4 = NEMA 4<br />

Optional Panel<br />

Variable Frequency Drive Models—2000 Series<br />

St<strong>and</strong>ard features include:<br />

Lock-out compatible throughthe-door<br />

manual disconnect switch<br />

with system fusing, 110 volt control<br />

circuit transformer with primary <strong>and</strong><br />

secondary fusing, mainline contactor,<br />

Variable Frequency Drive (VFD),<br />

brake relay, branch circuit fusing for<br />

bridge, auto-reset thermal overload<br />

relay, <strong>and</strong> bottom hinged door.<br />

These panels can be used for dual<br />

<strong>and</strong> multiple speed applications,<br />

infinitely variable speed applications<br />

<strong>and</strong> programmed acceleration/<br />

deceleration control. VFD comes<br />

pre-loaded with many easy-to-select<br />

programs to fit virtually any crane<br />

control application, <strong>and</strong> includes<br />

fault-code troubleshooting.<br />

Series<br />

2 = 2000 Series<br />

Series<br />

2 = 2000 Series<br />

Enclosure Rating<br />

1 = NEMA 1<br />

4 = NEMA 4<br />

Enclosure Rating<br />

1 = NEMA 1<br />

4 = NEMA 4<br />

2 1<br />

2 1<br />

4 3<br />

4 3<br />

Product Code<br />

Electrical Rating:<br />

Total System Amps/<br />

Drive Amps-Power Supply<br />

Electrical Rating:<br />

43 = 25 max./4 max.—460V/3/60<br />

Total System Amps/<br />

44 = 45 Drive max./12.5 Amps-Power max.—460V/3/60<br />

Supply<br />

23 = 25 max./8.6 max.—208-230V/3/60<br />

43 = 25 max./4 max.—460V/3/60<br />

24 = 75 max./24 max.—208-230V/3/60<br />

44 = 45 max./12.5 max.—460V/3/60<br />

23 = 25 max./8.6 max.—208-230V/3/60<br />

24 = 75 max./24 max.—208-230V/3/60