Consumer Units - WF Senate

wfsenate.co.uk

Consumer Units - WF Senate

Consumer

Units

Sector Consumer Units 218 - 222

& Accessories

Crabtree Consumer Units 223 - 224

& Accessories

Hager Consumer Units 225 - 226

& Accessories

MK Consumer Units 227 - 228

& Accessories

Wylex Consumer Units 229 - 232

& Accessories

Square D Consumer Units 232

Connect with the Best

217


Consumer Units

Sector Consumer Units

Consumer Units

Insulated Consumer Units

with Main Incomer

Complies with BS5486 Pt13 and BSEN60439.3.

Pre-assembled ready to accept MCBs.

Main incomer 100A DP (63A for 2 way board).

Fixed busbar 100A.

Complete with Earth and Neutral bars.

Smoked plastic door latches open.

Complete with cable knockouts.

Labels for circuit identification.

Modular devices can be fitted.

No of Main Dimensions mm Ref No. Order No.

Ways incomer (A) H D W 0001

2 63A 175 100 90 SVC2 126019

4 100 208 108 218 SVC4 126022

6 100 208 108 218 SVC6 126035

9 100 208 108 292 SVC9 126048

13 100 208 108 370 SVC13 126051

Insulated Fixed & Flexible Consumer Units

Split Load with 100A Main Incomer

Complies with BS5486 Pt13 and BSEN60439.3.

Pre-assembled ready to accept MCBs. (Fixed units only).

Main incomer 100A DP for all circuits, 80A 30mA DP RCD for

selected circuits.

Two fixed busbars 100A. (Fixed units only).

Complete with Earth and Neutral bars.

Prewired connection between Main switch & RCD.

Smoked plastic door latches open.

Complete with cable knockouts.

Labels for circuit identification.

Modular devices can be fitted.

No of Ways No of Ways Dimensions mm Ref No. Order No.

Unprotected protected H D W 0001

by RCD by RCD

Fixed Units

3 3 208 108 292 SVC3A3 126161

4 2 208 108 292 SVC4A2 126158

2 6 208 108 370 SVC2A6 126174

3 5 208 108 370 SVC3A5 126187

4 4 208 108 370 SVC4A4 126190

5 3 208 108 370 SVC5A3 126200

6 3 208 108 370 SVC6A3 126213

4 6 208 108 370 SVC4A6 126226

5 5 208 108 370 SVC5A5 126239

6 4 208 108 370 SVC6A4 126242

7 3 208 108 370 SVC7A3 126255

7 7 208 108 370 SVC7A7 126268

No of Usable Dimensions mm Ref No. Order No.

Ways H D W 0001

Flexible Units

12 ways 208 108 370 SVC12FSL 143885

218


Consumer Units

Sector Consumer Units

Connect with

the Best

Insulated Consumer Units - Split Load with

Time Delayed 100A RCD Main Incomer

Complies with BS5486 Pt13 and BSEN60439.3.

Pre-assembled ready to accept MCBs.

Main incomer 100A 100mA time delay RCD controls all circuits

and RCD 80A 30mA DP switch for selected circuits.

Two fixed busbars 100A.

Complete with Earth and Neutral bars.

Smoked plastic door latches open.

Complete with cable knockouts.

Labels for circuit identification.

Modular devices can be fitted.

Ideal for overhead line (TT) incoming supply in rural locations.

No of Ways No of Ways Dimensions mm Ref No. Order No.

Unprotected protected H D W 0001

by RCD by RCD

5 5 208 108 370 SVCBD5A5 133824

Insulated Consumer Units

with RCD Main Incomer

Complies with BS5486 Pt13 and BSEN60439.3.

Pre-assembled ready to accept MCBs.

Main incomer 80A, 30mA or 100mA sensitivity

(63A, 30mA for 2 way unit).

Fixed busbars 100A.

Complete with Earth and Neutral bars.

Smoked plastic door latches open.

Complete with cable knockouts.

Labels for circuit identification.

Modular devices can be fitted.

No of RCD Dimensions mm Ref No. Order No.

Ways Rating H D W 0001

2 63A, 30mA 175 100 90 SVCA2 126064

4 80A, 30mA 208 108 218 SVCA4 126077

6 80A, 30mA 208 108 218 SVCA6 126080

9 80A, 30mA 208 108 292 SVCA9 126093

13 80A, 30mA 208 108 370 SVCA13 126103

4 80A, 100mA 208 108 218 SVCB4 126116

6 80A, 100mA 208 108 218 SVCB6 126129

9 80A, 100mA 208 108 292 SVCB9 126132

13 80A, 100mA 208 108 370 SVCB13 126145

219


Consumer Units

Sector Consumer Units

Insulated Enclosure - IP20

Description Ref No. Order No.

0001

2 Module Insulated Enclosure without Lid SE2 126514

4 Module Insulated Enclosure without Lid SE4 133837

BUSBAR

SHROUD

Metal Clad Distribution Boards

with 100A Main Incomer

SP & N distribution boards comply with BSEN60439.3.

Pre-assembled ready to accept MCBs.

Robust construction of 1.2mm sheet steel and

epoxy powder coated.

IP 30 in accordance with IEC-529.

Rated voltage 240V AC 50/60Hz.

Fixed busbar 100A.

All outgoing ways numbered for ease of identification.

Complete with Earth and Neutral bars.

Smoked plastic door.

Complete with cable knockouts.

Modular devices can be fitted.

No of Main Dimensions mm Ref No. Order No.

Ways incomer (A) H D W 0001

2 63 175 100 90 SVCM2 126271

BLANK PLATES

4 100 208 117 218 SVCM4 126284

6 100 208 117 218 SVCM6 126297

9 100 208 117 292 SVCM9 126307

13 100 208 117 370 SVCM13 126310

Consumer Unit Accessories

Description Ref No. Order No.

0001

Busbar Shroud for 3 MCB Ways SSHR3 126543

Blank Plate 4 Ways SBLNK4 126530

220


Consumer Units

Connect with

the Best

Sector Consumer Units & Accessories

Metal Enclosure

Description Ref No. Order No.

0001

4 Module Metal Enclosure without Lid SFOR4 126527

Metal Clad Distribution Boards

with RCD Main Incomer

SP & N distribution boards comply with BSEN60439.3.

Pre-assembled ready to accept MCBs.

Robust construction of 1.2mm sheet steel and

epoxy powder coated.

IP 30 in accordance with IEC-529.

Rated voltage 240V AC 50/60Hz.

Fixed busbar 100A.

All outgoing ways numbered for ease of identification.

Complete with Earth and Neutral bars.

Smoked plastic door.

Complete with cable knockouts.

Modular devices can be fitted.

No of RCD Dimensions mm Ref No. Order No.

Ways Rating H D W 0001

2 63A, 30mA 175 100 90 SVCMA2 126323

4 80A, 30mA 208 108 218 SVCMA4 126336

6 80A, 30mA 208 108 218 SVCMA6 126349

Single Pole Miniature Circuit Breakers

Type B, 6kA breaking capacity.

Complies with BSEN60898.

Current limiting operation under fault conditions.

Rating (A) Ref No. Order No.

0001

6 SE6B 126352

10 SE10B 126365

16 SE16B 126378

20 SE20B 126381

32 SE32B 126394

40 SE40B 126404

50 SE50B 143898

221


Consumer Units

Sector Consumer Unit Accessories

Bell Transformer

Primary voltage 230/240V AC 50/60Hz.

The transformer provides extra safe low voltage.

Positive contact indication.

Secondary Ref No. Order No.

Voltage 0001

6, 8 & 12V AC STRB5 126556

RCBO Combined MCB / RCD

Complies with BSEN61009.

All the features of a MCB and RCD in a compact device.

Short circuit 6kA, Type B, 30mA.

RCBO (MCB / RCD) with Flying Lead:

For use in all Sector consumer units.

RCBO (MCB / RCD) without Flying Lead:

For stand alone applications.

Suitable for mounting in separate SE2 and SFO Sector enclosures.

Ideal for protecting bathroom electrical equipment.

including showers and heaters.

Rating (A) mA Ref No. Order No.

0001

MCB/RCD with Flying Lead

16 30 SSTA16BFL 126417

32 30 SSTA32BFL 126420

MCB/RCD without Flying Lead

40 30 SSTA40B 133840

Residual Current Devices (RCD)

Complies with BSEN61008.

Can be used as main switch disconnector or stand alone applications.

Suitable for mounting in seperate SE2 and SFO Sector enclosures.

Box clamp terminal - 1 to 25mm 2 .

Rating (A) mA Ref No. Order No.

0001

25 30 SRA25/2D 126433

40 30 SRA40/2D 126459

63 30 SRA63/2D 126475

80 30 SRA80/2D 126491

25 100 SRB25/2D 126446

40 100 SRB40/2D 126462

63 100 SRB63/2D 126488

80 100 SRB80/2D 126501

222


Consumer Units

Crabtree Consumer Units

Connect with

the Best

STARBREAKER Insulated Consumer Units

with Main Incomer

Complies with BS5486 Pt13 and BSEN60439-3.

Main incomer 100A DP (63A for 2 way board).

Simple site conversion to split load utilising

new split load busbar + split load RCD - Please ask for details.

No of Main Dimensions mm Ref No. Order No.

Ways Incomer (A) H W D 2825

2 63 160 117 102 402/2B 988020

4 100 230 190 120 404/2B 988046

7 100 230 243 120 407/2B 988059

10 100 230 294 120 410/2B 988062

13 100 230 344 120 413/2B 027088

18 100 230 439 120 418/2B 988088

STARBREAKER Insulated Consumer Units

Split Load with 100A Main Incomer and

80A RCD

Complies with BS5486 Pt13 and BSEN60439-3.

Main incomer 100A DP for all circuits plus 80A RCD 30mA DP.

Split easily re-configured by utilising alternate split load busbar

- Please ask for details.

No of No of Dimensions mm Ref No. Order No.

Unprotected Protected H W D 2825

Ways

Ways by RCD

4 3 230 294 120 407/2483B 041174

3 4 230 294 120 407/2383B 041161

7 3 230 344 120 410/2783B 041239

6 4 230 344 120 410/2683B 041242

5 5 (63A) 230 344 120 410/2563B 027101

5 5 230 344 120 410/2583B 027114

4 6 230 344 120 410/2483B 041213

3 7 230 344 120 410/2383B 041200

10 5 230 439 120 415/2183B 041284

9 6 230 439 120 415/2983B 041336

8 7 230 439 120 415/2883B 041323

7 8 230 439 120 415/2783B 041310

6 9 230 439 120 415/2683B 041307

5 10 230 439 120 415/2583B 041297

STARBREAKER Insulated Consumer Units

with RCD Main Incomer

Complies with BS5486 Pt13 and BSEN60439-3.

Main incomer 100A, 30mA trip (63A, 30mA for 2 way unit).

Other RCD options available - Please ask for details.

No of Main RCD Dimensions mm Ref No. Order No.

Ways Incomer (A) H W D 2825

2 63, 30mA 160 117 102 402/363B 988101

4 100, 30mA 230 190 120 404/383B 988127

7 100, 30mA 230 243 120 407/313B 041129

10 100, 30mA 230 294 120 410/313B 988156

13 100, 30mA 230 344 120 413/313B 988172

18 100, 30mA 230 439 120 418/313B 988198

223


Consumer Units

Crabtree Consumer Unit Accessories

Single Pole Miniature Circuit Breakers

Type B, 6kA breaking capacity.

BSEN60898.

Rating (A) Ref No. Order No.

2825

6 61/B06 572070

10 61/B10 572083

16 61/B16 572096

20 61/B20 572106

32 61/B32 572119

40 61/B40 572122

50 61/B50 991415

Blank Plate 4 ways 443 988622

Residual Current Devices (RCD) Double Pole

Complies with BSEN61008.

Electro-mechanical.

50mm terminal capacity.

Rating (A) mA Ref No. Order No.

2825

40 30 340/030 572339

63 30 363/030 991402

80 30 380/030 572371

100 30 310/030 575145

40 100 340/100 572342

80 100 380/100 572384

100 100 310/100 575158

100 100 time delay 310/100TD 575161

MCB/RCD (RCBO) with Flying Lead

For use in all Starbreaker consumer units.

Complies with BSEN61009.

Single module 6kA, Type C, 30mA.

35mm terminal capacity.

Rating (A) mA Ref No. Order No.

2825

6 30 61/C10630 991431

10 30 61/C11030 991444

16 30 61/C11630 991457

20 30 61/C12030 991460

32 30 61/C13230 991473

40 30 61/C14030 991486

224


Consumer Units

Hager Consumer Units

Connect with

the Best

VISION Insulated Consumer Units

with Main Incomer

Complies with BSEN60439-3.

Main incomer 63A or 100A DP.

No of Main Dimensions mm Ref No. Order No.

Ways Incomer (A) H W D 4484

2 63 160 117 112 VCOS2-06 026703

3 63 231 220 112 VCOS3-06 026716

4 63 231 220 112 VCOS4-06 026729

6 63 231 291 112 VCOS6-06 026732

4 100 231 220 112 VCOS4-01 026745

6 100 231 291 112 VCOS6-01 026758

8 100 231 291 112 VCOS8-01 026761

10 100 231 383 112 VCOS10-01 026774

12 100 231 383 112 VCOS12-01 026787

14 100 231 455 112 VCOS14-01 026790

16 100 231 455 112 VCOS16-01 026800

VISION Insulated Consumer Units Split Load

with 100A Main Incomer and 63A or 100A RCD

Complies with BSEN60439-3.

Main incomer 100A DP for all circuits plus 63A / 100A 30mA DP RCD.

No of Ways No of Ways Dimensions mm Ref No. Order No.

Protected Unprotected H W D 4484

by 63A RCD by RCD

2 4 231 291 112 VECOS24-6H 026981

3 3 231 291 112 VECOS33-6H 026994

4 2 231 291 112 VECOS42-6H 027003

4 4 231 383 112 VECOS44-6H 031853

4 6 231 383 112 VECOS46-6H 029001

5 5 231 383 112 VECOS55-6H 028442

6 4 231 383 112 VECOS64-6H 029027

6 6 231 455 112 VECOS66-6H 027029

No of Ways No of Ways Dimensions mm Ref No. Order No.

Protected Unprotected H W D 4484

by 100A RCD by RCD

5 5 231 383 112 VECOS55-10H 027058

6 4 231 383 112 VECOS64-10H 027061

8 4 231 455 112 VECOS84-10H 027090

7 7 231 455 112 VECOS77-10H 029030

GD102E

VISION Insulated Consumer Units

with RCD Main Incomer

Complies with BSEN60439-3.

Main incomer 63A or 100A, 30mA.

No of Main RCD Dimensions mm Ref No. Order No.

Ways Incomer (A) H W D 4484

2 63A, 30mA 193 167 112 VECOS2-6H 026813

3 63A, 30mA 231 220 112 VECOS3-6H 026826

4 63A, 30mA 231 220 112 VECOS4-6H 026839

6 63A, 30mA 231 291 112 VECOS6-6H 026842

8 63A, 30mA 231 291 112 VECOS8-6H 026855

6 100A, 30mA 231 291 112 VECOS6-10H 026871

8 100A, 30mA 231 291 112 VECOS8-10H 026884

10 100A, 30mA 231 455 112 VECOS10-10H 026897

12 100A, 30mA 231 455 112 VECOS12-10H 026907

Mini Gamma Insulated Enclosures - IP30

GD106E

Complete with Din Rail & Earth Terminal (Except 2 way unit).

Plain & transparent door available on request.

No of Dimensions mm Ref No. Order No.

Ways H W D 4484

2 55 160 82 GD102E 002277

4 110 180 82 GD104E 002280

6 182 180 82 GD106E 002293

8 218 180 82 GD108E 002303

225


Consumer Units

Hager Consumer Unit Accessories

Single Pole Miniature Circuit Breakers

Complies with BSEN60898.

Type B, 6kA breaking capacity.

Rating (A) Ref No. Order No.

4484

6 MTN106 003742

10 MTN110 003755

16 MTN116 003768

20 MTN120 003771

32 MTN132 003917

40 MTN140 003962

50 MTN150 003975

63 MTN163 003988

RCBOs (Combined MCB / RCD) Single Pole

Complies with BSEN61008.

All the features of a MCB and RCD in a compact device.

Short circuit 6kA, Type B, 30mA (Type C available on request).

Rating (A) mA Ref No. Order No.

4484

6A 30 AD104 024459

10A 30 AD105 024462

16A 30 AD107 024475

20A 30 AD108 024488

32A 30 AD110 024501

40A 30 AD111 024514

45A 30 AD112 024527

VG01B

VG01C

Residual Current Devices (RCD) Double Pole

Complies with BSEN61008.

Rating (A) mA Ref No. Order No.

4484

25 30 CDC225U 003098

40 30 CDC240U 003124

63 30 CDC263U 003153

80 30 CD280U 024734

100 30 CD284U 024747

Consumer Unit Accessories

Description Ref No. Order No.

4484

Single Module Blank - Shrouds Bussbar VG01B 022927

& Blank Spare Ways

Single Module Blank - Blanks DIN Rail VG01C 028196

Ways Only

226


Consumer Units

MK Consumer Units

Connect with

the Best

SENTRY Insulated Consumer Units

with Main Incomer

Degree of protection to BS EN60529/IP2XC BN EN 604439-3

1991/A11994.

Factory build units on request.

Order main incomer switch separately - Takes 2 module spaces.

No of Dimensions mm Ref No. Order No.

Modules W H D 5779

4 140 230 110 K5604s 003508

8 234 230 110 K5608s 003634

12 306 230 110 K5612s 003511

16 378 230 110 K5616s 003524

21 468 230 110 K5621s 003647

Main Incomers

Description Ref No. Order No.

5779

63A Main Incomer (Use on 4 Module Board Only) 5560s 001885

100A Main Incomer 5500s 001775

SENTRY Consumer Units

Split Load with 100A Main Incomer

Pre fitted with 100A switch disconnector

and 80A 30mA RCD or 63A 30mA RCD.

Flexible design allowing RCD to be positioned to suit the

required configuration of protected/non-protected circuits.

All necessary split-load cabling included.

No of RCD Dimensions mm Ref No. Order No.

modules Rating W H D 5779

Insulated Version

8 63A, 30mA 306 230 110 K5682s 003566

12 63A, 30mA 378 230 110 K5666s 003553

8 80A, 30mA 306 230 110 K5662s 003540

12 80A, 30mA 378 230 110 K5686s 003579

17 80A, 30mA 468 230 110 K5681s 003605

Metal Version

8 63A, 30mA 306 230 110 K5582s 003472

12 63A, 30mA 378 230 110 K5566s 003618

12 80A, 30mA 378 230 110 K5586s 003485

17 80A, 30mA 468 230 110 K5581s 003621

Consumer Unit Accessories

Description Ref No. Order No.

5779

MCB Blank Plate Cover Mount K5545S 000006

11 Way Busbar K5511S 003414

227


Consumer Units

MK Consumer Unit Accessories

Single Pole Miniature Circuit Breakers

Type B, 6kA breaking capacity.

Complies with BSEN60898.

Rating (A) Ref No. Order No.

5779

3 5903s 002334

6 5906s 002347

10 5910s 002350

16 5916s 002363

20 5920s 002376

32 5932s 002389

40 5940s 002392

45 5945s 002402

50 5950s 002415

RCBO (combined MCB/RCD) Single Pole

Comply with BSEN61009-1 BSEN61009-2-2.

All the features of a MCB and RCD in a compact device.

Short circuit 6kA, Type B, 30mA.

Rating (A) mA Ref No. Order No.

5779

6A 30 6932s 003223

10A 30 6933s 003236

16A 30 6934s 003249

20A 30 6935s 003252

32A 30 6936s 003265

40A 30 6937s 003278

45A 30 6938s 003281

Residual Current Devices (RCD) Double Pole

Complies with BSEN61008.

Rating (A) mA Ref No. Order No.

5779

40 30 5740s 002211

63 30 5760s 002237

80 30 5780s 002240

100 30 7700s 002790

63 100 6160s 002431

80 100 6180s 002444

100 100 6600s 002664

Bell Transformer

Primary voltage 230/240V AC 50/60Hz.

The transformer provides extra safe low voltage.

Rating Ref No. Order No.

5779

1A at 8V Primary 5711s 002198

228


Consumer Units

Wylex Consumer Units

Connect with

the Best

NH Insulated Consumer Units with Main Incomer

Complies with BSEN60439.

Main incomer 100A DP (40A or 63A for 2 way board).

No of Main Dimensions mm Ref No. Order No.

Ways Incomer (A) H W D 7725

2 40 175 117 102 NH204/40 025169

2 63 160 117 102 NH204/63 025172

5 100 230 187 120 NH504 025428

8 100 230 240 120 NH804 025431

11 100 230 290 120 NH1104 025444

14 100 230 340 120 NH1404 025457

19 100 230 435 120 NH1904 025460

NH Insulated Consumer Units - FLEXIBLE Split Load

with 100A Main Incomer and 80A, 30mA RCD

Complies with BSEN60439.

Modular devices e.g. timers, bell transformer can be fitted

alongside MCBs.

No of Ways No of Ways Dimensions mm Ref No. Order No.

Unprotected Protected H W D 7725

by RCD by RCD

2 to 4 2 to 4 230 240 120 NHRS6SL 002917

3 to 6 3 to 6 230 290 120 NHRS9SL 027730

3 to 9 3 to 9 230 340 120 NHRS12SL 027727

5 to 12 5 to 12 230 435 120 NHRS17SL 000032

NH Insulated Consumer Units - Split Load with

100A Main Incomer and 80A, 30mA RCD

Complies with BSEN60439.

No of Ways No of Ways Dimensions mm Ref No. Order No.

Unprotected Protected H W D 7725

by RCD by RCD

4 2 230 240 120 NHRS2404 025680

3 3 230 240 120 NHRS3304 025693

5 4 230 290 120 NHRS4504 025729

4 5 230 290 120 NHRS5404 025716

3 6 230 290 120 NHRS6304 025745

6 6 230 340 120 NHRS6604 025774

10 7 230 435 120 NHRS71004 025868

4 8 230 340 120 NHRS8404 025800

3 9 230 340 120 NHRS9304 025813

7 10 230 435 120 NHRS10704 025842

5 12 232 435 120 NHRS12504 025826

NH Insulated Consumer Units with RCD Main

Incomer

Complies with BSEN60439.

Main incomer 100A, 30mA (except 2 way units 40A and 63A 30mA).

No of Main RCD Dimensions mm Ref No. Order No.

Ways Incomer (A) H W D 7725

2 40, 30mA 160 102 117 NHRS204/40 025185

2 63, 30mA 160 102 117 NHRS204/63 025198

5 100, 30mA 230 187 120 NHRS504 025305

8 100, 30mA 230 240 120 NHRS804 025318

11 100, 30mA 230 290 120 NHRS1104 025321

14 100, 30mA 230 340 120 NHRS1404 025334

19 100, 30mA 230 435 120 NHRS1904 025347

229


Consumer Units

Wylex Consumer Unit Accessories

RCBOs

RCD

NSB Single Pole Miniature Circuit Breakers

For use in NH Consumer Units.

Complies with BSEN60898.

Type B, 6kA breaking capacity.

Rating (A) Ref No. Order No.

7725

6 NSB06 016013

10 NSB10 016026

16 NSB16 016039

20 NSB20 016042

32 NSB32 016055

40 NSB40 016068

50 NSB50 027701

LIFELINE Residual Current Devices (RCD)

Complies with BSEN61009.

Up to 100A rating.

30mA personal protection.

100mA property protection.

Double Pole.

Rating (A) mA Ref No. Order No.

7725

40 30 WRS40/2 023307

63 30 WRS63/2 023310

80 30 WRS80/2 023323

100 30 WRS100/2 023336

40 100 WRM40/2 023941

63 100 WRM63/2 023349

80 100 WRM80/2 023954

100 100 WRM100/2 023967

NH00

NH Accessories

Description Ref No. Order No.

7725

Blanking Plate (Push Fit for Cover) NH00 026537

Busbar & Cover Blank Plate NHB1pp 003000

Bell Transformer

Primary 230v AC, secondary 12V AC 8vA.

NHB1PP

NSBS RCBO (Combined MCB/RCD)

Complies with BSEN61008.

Short circuit 6kA, Type C, 30mA rating.

Rating (A) mA Ref No. Order No.

7725

Single Pole

6A 30 NSBS6/1 027552

10A 30 NSBS10/1 027565

16A 30 NSBS16/1 027578

20A 30 NSBS20/1 027581

32A 30 NSBS32/1 027594

40A 30 NSBS40/1 027604

Double Pole

6A 30 NSBS6/2 017643

10A 30 NSBS10/2 017656

16A 30 NSBS16/2 017669

20A 30 NSBS20/2 017672

32A 30 NSBS32/2 017685

40A 30 NSBS40/2 023242

Description Ref No. Order No.

7725

Bell Transfomer MTS8 017397

230


Consumer Units

Wylex Consumer Unit Accessories

Connect with

the Best

Insulated STANDARD 1 way Switch Fuse

and Consumer Units with Main Incomer

1 way switch fuse or multi way consumer units.

Accepts fuses or MCBs.

No of Ways Main Dimensions mm Ref No. Order No.

Incomer (A) H W D 7725

1 way 45 121 68 98 104 000249

2 way 45 120 70 125 204 005419

3 way 60 155 95 190 304 000663

4 way 60 155 95 190 404 000825

6 way 100 186 103 272 604 001329

8 way 100 186 103 323 804 001811

Single Pole Miniature Circuit Breakers

For use in Standard Consumer Units

Complies with BSEN60898.

Type B, 3kA breaking capacity.

Rating (A) Ref No. Order No.

7725

6 B6 012622

10 B10 012635

16 B16 012648

20 B20 002153

32 B32 012651

40 B40 012664

Blank Plate M10 002409

Metal STANDARD 1 Way Switch Fuse

and Consumer Units with Main Incomer

1 way switch fuse or multi way consumer units.

Accepts fuses or MCBs.

No of Ways Main Dimensions mm Ref No. Order No.

Incomer (A) H W D 7725

1 way 45 131 80 112 106 004290

1 way 60 178 99 143 160CM* 000472

1 way 80 305 76 178 110M/80* 015616

1 way 100 305 76 178 110M 015603

2 way 45 131 93 140 206 004410

3 way 45 153 99 210 306 000702

4 way 60 154 99 210 406 000870

6 way 100 210 104 293 606 001374

* Supplied with cartridge fuse

Cartridge Fuse and Links

For use in Standard Consumer Units

Cartridge Fuse

Fuse Link

Rating (A) Colour Ref No. Order No. Ref No. Order No.

Code 7725 7725

5 White C5 002195 CFL5 002292

15 Blue C15 002218 CFL15 002302

20 Yellow C20 002234 CFL20 002315

30 Red C30 002250 CFL30 002328

45 Green C45 002276 CFL45 002331

Blank Base M10 002409

231


Consumer Units

Square D Consumer Units

Standard Rewirable Fuse Assemblies

For use in Standard Consumer Units

Rating (A) Colour Ref No. Order No.

Code 7725

5 White R5 003246

15 Blue R15 003262

20 Yellow R20 003288

30 Red R30 003301

Blank Plate M10 002409

DOMAE Consumer Unit

Complete Split Load Kits

To BSEN60439-3.

Main incomer 100A DP for all circuits plus 80A or 63A RCD 30mA DP.

Shrouded Busbar 100A.

Labels for circuit identification.

KITBOXD contains:

1 x DOM12CU - Main Board.

1 x DOM100SW - 100A Main incomer switch.

1 x DOM63R30KIT - 63A, 30mA RCD KIT (Including link cables).

10 x DOM MCBs (3 x 6A, 2 x 16A, 4 x 32A & 1 x 40A Type B, MCBs).

KITBOXD80 contains:

1 x DOM12CU - Main Board.

1 x DOM100SW - 100A Main incomer switch.

Power Controls Single Pole Mini Trip

Complies with BSEN60898.

Type B, 3kA breaking capacity.

Order trip and base.

Description Rating (A) Ref No. Order No.

4234

Mini Trip 5 SMT5 002032

Mini Trip 15 SMT15 002045

Mini Trip 20 SMT20 002058

Mini Trip 30 SMT30 002061

Mini Trip 45 SMT45 002074

Mini Trip Base 5 SMTB5 007781

Mini Trip Base 15 SMTB15 007794

Mini Trip Base 20 SMTB20 007804

Mini Trip Base 30 SMTB30 007817

Mini Trip Base 45 SMTB45 007820

1 x DOM80R30KIT - 80A, 30mA RCCD KIT (Including link cables).

10 x DOM MCBs (3 x 6A, 2 x 16A, 4 x 32A & 1 x 40A Type B, MCBs).

Description Dimensions mm Ref No. Order No.

H W D 8060

10 Way Consumer Unit Package 240 368 127 KITBOXD 002891

10 Way Consumer Unit Package 240 368 127 KITBOXD80 003366

232

More magazines by this user
Similar magazines