13.02.2014 Views

ESXi 5.1 Update - VMware Communities

ESXi 5.1 Update - VMware Communities

ESXi 5.1 Update - VMware Communities

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Project-Name : I12002-VM Perspecta Solutions Doc.-No. : I12002-003<br />

Doc.-Title : <strong>ESXi</strong> <strong>5.1</strong> <strong>Update</strong> Doc.-Version : 0.2<br />

INHALT / CONTENTS<br />

1 Einleitung ............................................................................................................. 4<br />

1.1 Zweck ............................................................................................................ 4<br />

1.2 Geltungsbereich ............................................................................................ 4<br />

1.3 Begriffe .......................................................................................................... 4<br />

1.4 Referenzen .................................................................................................... 4<br />

2 Installation <strong>ESXi</strong> <strong>5.1</strong> auf ProLiant DL180 G6..................................................... 5<br />

3 <strong>Update</strong> vSphere Client ........................................................................................ 6<br />

3.1 aber download bricht mehrmals nach 50% ab: ............................................. 6<br />

3.2 Download ab Supportseite und manuelle Deinstallation / neu-Installation.... 6<br />

4 Speicher – Smart Array Controller Fehler auf Host ......................................... 7<br />

4.1 Nach einschalten bestehender Virtuelle Maschinen (WinXP VM's) folgt<br />

folgende Fehlermeldung:............................................................................... 7<br />

4.2 neu seit <strong>Update</strong> <strong>ESXi</strong> ist folgende Warnung auf den Array Controller: ......... 8<br />

5 Upgrade HP Smart Array P410 Controller Firmware........................................ 9<br />

<strong>5.1</strong>.1 HP Support Center – HP Proliant DL180 G6 Server Support .............. 9<br />

6 Installation VIB HP driver Pack Sept 1012 ..................................................... 11<br />

6.1 HP Support Center – Drivers, Software and Firmware................................ 11<br />

6.2 Installation ................................................................................................... 11<br />

6.2.1 Prerequisites ...................................................................................... 11<br />

6.2.2 Procedure........................................................................................... 12<br />

6.2.3 CLI Hinweise ...................................................................................... 12<br />

6.2.4 Konsolendeinstallation und Installation mittels putty: ......................... 12<br />

6.3 Reboot RN-SV-05........................................................................................ 16<br />

6.3.1 Aber: der RN-VM-Win2012 Server macht immer noch ein reboot<br />

alle paar Minuten:............................................................................... 16<br />

6.3.2 Und die WinXP Server können nach wie vor nicht hoch gefahren<br />

werden,............................................................................................... 17<br />

6.4 Neuer Eintrag in Community Diskussion Upgrading <strong>ESXi</strong> 5.0 to <strong>ESXi</strong><br />

<strong>5.1</strong> HP Smart Array P410i Warning............................................................. 17<br />

6.5 Brack Tech Support Hotline......................................................................... 17<br />

6.6 HP business Support................................................................................... 17<br />

6.6.2 aber nach absenden des Fehlerberichtes neuer Hinweis auf<br />

Knowledge Base (2036572)............................................................... 23<br />

6.6.3 Downgrade again to hp-esxi5.0uX-bundle-1.3-12.............................. 26<br />

7 Eigenschaften Speicher Ressourcen (vSphere)............................................. 29<br />

8 Verschieben der VM’s auf LUN2 ...................................................................... 32<br />

9 Recommendations from <strong>VMware</strong> Community............................................... 34<br />

ANFORDERUNGEN / REQUIREMENTS<br />

Nummer / Number Seite / Page Nummer / Number Seite / Page<br />

Fehler! Keine Indexeinträge gefunden.<br />

I12002-003-<strong>ESXi</strong>51update.2.doc<br />

Page 3 of 35 2013-04-12


Project-Name : I12002-VM Perspecta Solutions Doc.-No. : I12002-003<br />

Doc.-Title : <strong>ESXi</strong> <strong>5.1</strong> <strong>Update</strong> Doc.-Version : 0.2<br />

1 EINLEITUNG<br />

1.1 Zweck<br />

Dieses Dok dient als Anleitung zur Reproduktion und als Logfile für die durchgeführten Schritte<br />

beim Upgrade von <strong>ESXi</strong> 5.0 auf <strong>5.1</strong> mit anschliessender Treiberaktualisierung und Bugfix<br />

Massnahmen<br />

1.2 Geltungsbereich<br />

n/a<br />

1.3 Begriffe<br />

1.4 Referenzen<br />

I12002-003-<strong>ESXi</strong>51update.2.doc<br />

Page 4 of 35 2013-04-12


Project-Name : I12002-VM Perspecta Solutions Doc.-No. : I12002-003<br />

Doc.-Title : <strong>ESXi</strong> <strong>5.1</strong> <strong>Update</strong> Doc.-Version : 0.2<br />

6 INSTALLATION VIB HP DRIVER PACK SEPT 1012<br />

Gemäss Forum http://communities.vmware.com/thread/438699 sind Treiber in März Release<br />

buggy und müssen auf Treiber Sept 04 downgraded werden:<br />

6.1 HP Support Center – Drivers, Software and Firmware<br />

http://h20565.www2.hp.com/portal/site/hpsc/template.PAGE/public/psi/swdDetails/?sp4ts.oid=5214568&spf_p.tpst=swdMain&spf_p.prp<br />

_swdMain=wsrpnavigationalState%3Didx%253D2%257CswItem%253DMTX_f13f6dc749e348009133fcefd2%257CswEnvOID%253D4141%257CitemL<br />

ocale%253D%257CswLang%253D%257Cmode%253D4%257Caction%253DdriverDocument&javax.portlet.begCacheTok=com.vignett<br />

e.cachetoken&javax.portlet.endCacheTok=com.vignette.cachetoken<br />

* RECOMMENDED * HP <strong>ESXi</strong> Offline Bundle for <strong>VMware</strong> <strong>ESXi</strong> 5.x<br />

By downloading, you agree to the terms and conditions of the HP Software License Agreement.<br />

Type:<br />

Software - System Management<br />

Version: 1.3 (4 Sep 2012)<br />

Operating System(s): <strong>VMware</strong> <strong>ESXi</strong> 5.0, <strong>VMware</strong> vSphere <strong>5.1</strong><br />

File name:<br />

hp-esxi5.0uX-bundle-1.3-12.zip (9.2 MB)<br />

To ensure the integrity of your download, HP recommends verifying your results with this MD5<br />

Checksum value<br />

hp-esxi5.0uX-bundle-1.3-12.zip f0fae7ebfa0e48b899eb2c8ed5d0fa38<br />

Reboot Requirement<br />

Reboot is required after installation for updates to take effect and hardware stability to be<br />

maintained.<br />

6.2 Installation<br />

Installing Offline Bundles on an <strong>ESXi</strong> 5.x Host Using vSphere CLI 5.0 esxcli Utility<br />

You can use the esxcli utility in conjunction with offline bundles or with a depot. This topic<br />

describes the procedure using offline bundles.<br />

This bundle includes the following software versions<br />

•cross_oem-hp-smx-provider_500.03.01.00.5-434156<br />

•cross_oem-vmware-esx-drivers-char-500.9.0.0.9-1OEM.500.0.0.434156<br />

•cross_oem-vmware-esx-drivers-char-hpcru_5.0.2.21-1OEM.500.0.0.434156<br />

•cross_oem-hp-ams_500.9.2.0-11.434156. This is not intended for <strong>VMware</strong> <strong>ESXi</strong> 4.1.x.<br />

6.2.1 Prerequisites<br />

Before you can update or patch an <strong>ESXi</strong> 5.0 host from the command line, you must have access to<br />

a machine on which you can run the <strong>VMware</strong> vSphere Command-Line Interface 5.x (vSphere CLI).<br />

You can install the vSphere CLI on your Microsoft Windows or Linux system. For information about<br />

importing or installing the vSphere CLI 5.x, see the <strong>VMware</strong> vSphere Command-Line Interface<br />

Installation and Reference Guide.<br />

I12002-003-<strong>ESXi</strong>51update.2.doc<br />

Page 11 of 35 2013-04-12


Project-Name : I12002-VM Perspecta Solutions Doc.-No. : I12002-003<br />

Doc.-Title : <strong>ESXi</strong> <strong>5.1</strong> <strong>Update</strong> Doc.-Version : 0.2<br />

6.2.2 Procedure<br />

1. Power off any virtual machines that are running on the host and place the host into maintenance<br />

mode.<br />

2. Transfer the offline bundle onto the <strong>ESXi</strong> host local path, or extract it onto an online depot.<br />

3. Install the bundle on the <strong>ESXi</strong> host.<br />

• Install remotely from client, with offline bundle contents on a online depot:<br />

esxcli -s -u root -p mypassword software vib install -d <br />

• Install remotely from client, with offline bundle on <strong>ESXi</strong> host:<br />

esxcli -s -u root -p mypassword software vib install -d <br />

• Install from <strong>ESXi</strong> host, with offline bundle on <strong>ESXi</strong> host:<br />

esxcli software vib install -d <br />

4. After the bundle is installed, reboot the <strong>ESXi</strong> host for the updates to take effect.<br />

5. (Optional) Verify that the vibs on the bundle are installed on your <strong>ESXi</strong> host.<br />

esxcli -s -u root -p mypassword software vib list<br />

6. (Optional) Remove individual vibs. can be identified by listing the vibs as shown in<br />

#5.<br />

esxcli -s -u root -p mypassword software vib remove -n <br />

6.2.2.1 Installing Offline Bundles on an <strong>ESXi</strong> 5.x Host Using <strong>VMware</strong> vCenter <strong>Update</strong><br />

Manager<br />

The offline bundle can also be installed from <strong>VMware</strong> vCenter <strong>Update</strong> Manager as a patch. For<br />

more information and detailed instructions, see the <strong>VMware</strong> vCenter <strong>Update</strong> Manager<br />

Administration Guide.<br />

6.2.3 CLI Hinweise<br />

http://www.thomas-krenn.com/de/wiki/Esxcli_-_VIB_auf_einem_<strong>ESXi</strong>_5.0_Host_installieren<br />

6.2.4 Konsolendeinstallation und Installation mittels putty:<br />

login as: root<br />

Using keyboard-interactive authentication.<br />

Password:<br />

The time and date of this login have been sent to the system logs.<br />

<strong>VMware</strong> offers supported, powerful system administration tools. Please see<br />

www.vmware.com/go/sysadmintools for details.<br />

The <strong>ESXi</strong> Shell can be disabled by an administrative user. See the vSphere Security documentation for<br />

more information.<br />

I12002-003-<strong>ESXi</strong>51update.2.doc<br />

Page 12 of 35 2013-04-12


Project-Name : I12002-VM Perspecta Solutions Doc.-No. : I12002-003<br />

Doc.-Title : <strong>ESXi</strong> <strong>5.1</strong> <strong>Update</strong> Doc.-Version : 0.2<br />

~ # cd /vmfs/volumes/50fdc63e-3da28ca5-2df5-e4115be23b79/HpdriverPack<br />

~ # esxcli software vib remove –n hp-smx-provider<br />

~ # esxcli software vib remove –n char-hpilo<br />

~ # esxcli software vib remove –n char-hpcru<br />

~ # esxcli software vib remove –n hp-ams<br />

~ # esxcli software vib remove –n hpacucli<br />

~ # esxcli software vib remove –n hpbootcfg<br />

~ # esxcli software vib remove –n hponcfg<br />

~ # esxcli software vib remove –n hpnmi<br />

~ # reboot<br />

~ # esxcli software vib install -d /vmfs/volumes/50fdc63e-3da28ca5-2df5-<br />

e4115be23b79/HPdriverPack/metadata-hp-esxi5.0uX-bundle-1.3-12.zip<br />

[MetadataDownloadError]<br />

Could not download from depot at zip:/vmfs/volumes/50fdc63e-3da28ca5-2df5-<br />

e4115be23b79/HPdriverPack/metadata-hp-esxi5.0uX-bundle-1.3-12.zip?index.xml,<br />

skipping (('zip:/vmfs/volumes/50fdc63e-3da28ca5-2df5-e4115be23b79/HPdriverPack/metadata-hpesxi5.0uX-bundle-1.3-12.zip?index.xml',<br />

'', 'Error extracting index.xml from /vmfs/volumes/50fdc63e-<br />

3da28ca5-2df5-e4115be23b79/HPdriverPack/metadata-hp-esxi5.0uX-bundle-1.3-12.zip: "There is no item<br />

named \'index.xml\' in the archive"')) url = zip:/vmfs/volumes/50fdc63e-3da28ca5-2df5-<br />

e4115be23b79/HPdriverPack/metadata-hp-esxi5.0uX-bundle-1.3-12.zip?index.xml<br />

Please refer to the log file for more details.<br />

~ #<br />

falsches Zipfile als Depot: nicht nur metadata-zip !<br />

~ # esxcli software vib install -d /vmfs/volumes/50fdc63e-3da28ca5-2df5-<br />

e4115be23b79/HPdriverPack/hp-esxi5.0uX-bundle-1.3-12.zip<br />

Installation Result<br />

Message: The update completed successfully, but the system needs to be rebooted for the changes<br />

to be effective.<br />

Reboot Required: true<br />

VIBs Installed: Hewlett-Packard_bootbank_char-hpcru_5.0.2.21-1OEM.500.0.0.434156, Hewlett-<br />

Packard_bootbank_char-hpilo_500.9.0.0.9-1OEM.500.0.0.434156,<br />

Hewlett-Packard_bootbank_hp-ams_500.9.2.0-11.434156, Hewlett-Packard_bootbank_hp-smxprovider_500.03.01.00.5-434156<br />

VIBs Removed:<br />

VIBs Skipped:<br />

~ #<br />

~ # esxcli software vib list | grep -i hp<br />

Name Version Vendor Accept.Level InstallDate<br />

----------------------------- ------------------------------------ --------------- ---------------- ----------<br />

char-hpcru 5.0.2.21-1OEM.500.0.0.434156 Hewlett-Packard PartnerSupported 2013-04-12<br />

char-hpilo 500.9.0.0.9-1OEM.500.0.0.434156 Hewlett-Packard PartnerSupported 2013-04-12<br />

hp-ams 500.9.2.0-11.434156 Hewlett-Packard PartnerSupported 2013-04-12<br />

hp-build 5.34.23-434156 Hewlett-Packard PartnerSupported 2013-04-05<br />

hp-smx-provider 500.03.01.00.5-434156 Hewlett-Packard <strong>VMware</strong>Accepted 2013-04-12<br />

scsi-hpsa 5.0.0-40OEM.500.0.0.472560 Hewlett-Packard <strong>VMware</strong>Certified 2013-04-05<br />

scsi-hpvsa 5.0.0-50OEM.500.0.0.472560 Hewlett-Packard PartnerSupported 2013-04-05<br />

vmware-esx-hp_vaaip_p2000 2.1.0-2 Hewlett-Packard <strong>VMware</strong>Accepted 2013-04-05<br />

ata-pata-hpt3x2n 0.3.4-3vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

~ #<br />

I12002-003-<strong>ESXi</strong>51update.2.doc<br />

Page 13 of 35 2013-04-12


Project-Name : I12002-VM Perspecta Solutions Doc.-No. : I12002-003<br />

Doc.-Title : <strong>ESXi</strong> <strong>5.1</strong> <strong>Update</strong> Doc.-Version : 0.2<br />

~ # esxcli software vib list<br />

Name Version Vendor Accept. Level Install Date<br />

----------------------------- ------------------------------------ --------------- ---------------- ----------<br />

misc-cnic-register 1.72.1.v50.2-1OEM.500.0.0.472560 Broadcom <strong>VMware</strong>Certified 2013-04-05<br />

net-bnx2 2.2.3e.v50.1-1OEM.500.0.0.472560 Broadcom <strong>VMware</strong>Certified 2013-04-05<br />

net-bnx2x 1.74.17.v50.1-1OEM.500.0.0.472560 Broadcom <strong>VMware</strong>Certified 2013-04-05<br />

net-cnic 1.74.04.v50.1-1OEM.500.0.0.472560 Broadcom <strong>VMware</strong>Certified 2013-04-05<br />

net-tg3 3.124c.v50.1-1OEM.500.0.0.472560 Broadcom <strong>VMware</strong>Certified 2013-04-05<br />

scsi-bnx2fc 1.74.02.v50.2-1OEM.500.0.0.406165 Broadcom <strong>VMware</strong>Certified 2013-04-05<br />

scsi-bnx2i 2.74.07.v50.1-1OEM.500.0.0.472560 Broadcom <strong>VMware</strong>Certified 2013-04-05<br />

scsi-bfa 3.0.0.0-1OEM.500.0.0.406165 Brocade <strong>VMware</strong>Certified 2013-04-05<br />

ima-be2iscsi 4.2.324.12-1OEM.500.0.0.472629 Emulex <strong>VMware</strong>Certified 2013-04-05<br />

net-be2net 4.2.327.0-1OEM.500.0.0.472560 Emulex <strong>VMware</strong>Certified 2013-04-05<br />

scsi-be2iscsi 4.2.324.12-1OEM.500.0.0.472629 Emulex <strong>VMware</strong>Certified 2013-04-05<br />

scsi-lpfc820 8.2.4.141.55-1OEM.500.0.0.472560 Emulex <strong>VMware</strong>Certified 2013-04-05<br />

char-hpcru 5.0.2.21-1OEM.500.0.0.434156 Hewlett-Packard PartnerSupported 2013-04-12<br />

char-hpilo 500.9.0.0.9-1OEM.500.0.0.434156 Hewlett-Packard PartnerSupported 2013-04-12<br />

hp-ams 500.9.2.0-11.434156 Hewlett-Packard PartnerSupported 2013-04-12<br />

hp-build 5.34.23-434156 Hewlett-Packard PartnerSupported 2013-04-05<br />

hp-smx-provider 500.03.01.00.5-434156 Hewlett-Packard <strong>VMware</strong>Accepted 2013-04-12<br />

scsi-hpsa 5.0.0-40OEM.500.0.0.472560 Hewlett-Packard <strong>VMware</strong>Certified 2013-04-05<br />

scsi-hpvsa 5.0.0-50OEM.500.0.0.472560 Hewlett-Packard PartnerSupported 2013-04-05<br />

vmware-esx-hp_vaaip_p2000 2.1.0-2 Hewlett-Packard <strong>VMware</strong>Accepted 2013-04-05<br />

net-igb 4.0.17-1OEM.500.0.0.472560 Intel <strong>VMware</strong>Certified 2013-04-05<br />

net-ixgbe 3.11.32-1OEM.500.0.0.472560 Intel <strong>VMware</strong>Certified 2013-04-05<br />

scsi-mpt2sas 13.10.02.00.1vmw-1OEM.500.0.0.472560 LSI <strong>VMware</strong>Certified 2013-04-05<br />

net-mlx4-en 1.6.1.2-1OEM.500.0.0.406165 Mellanox <strong>VMware</strong>Certified 2013-04-05<br />

ima-qla4xxx 500.2.01.31-1vmw.0.0.060523 QLogic <strong>VMware</strong>Certified 2013-04-05<br />

net-qlcnic 5.0.750-1OEM.500.0.0.472560 QLogic <strong>VMware</strong>Certified 2013-04-05<br />

scsi-qla4xxx 634.0.5.0-1OEM.500.0.0.472560 QLogic <strong>VMware</strong>Certified 2013-04-05<br />

ata-pata-amd 0.3.10-3vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

ata-pata-atiixp 0.4.6-4vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

ata-pata-cmd64x 0.2.5-3vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

ata-pata-hpt3x2n 0.3.4-3vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

ata-pata-pdc2027x 1.0-3vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

ata-pata-serverworks 0.4.3-3vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

ata-pata-sil680 0.4.8-3vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

ata-pata-via 0.3.3-2vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

block-cciss 3.6.14-10vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

ehci-ehci-hcd 1.0-3vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

esx-base <strong>5.1</strong>.0-0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

esx-dvfilter-generic-fastpath <strong>5.1</strong>.0-0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

esx-tboot <strong>5.1</strong>.0-0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

esx-xlibs <strong>5.1</strong>.0-0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

esx-xserver <strong>5.1</strong>.0-0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

ipmi-ipmi-devintf 39.1-4vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

ipmi-ipmi-msghandler 39.1-4vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

ipmi-ipmi-si-drv 39.1-4vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

misc-drivers <strong>5.1</strong>.0-0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

net-e1000 8.0.3.1-2vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

net-e1000e 1.1.2-3vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

net-enic 1.4.2.15a-1vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

net-forcedeth 0.61-2vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

net-nx-nic 5.0.626-3vmw.500.0.0.472560 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

net-r8168 8.013.00-3vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

net-r8169 6.011.00-2vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

net-s2io 2.1.4.13427-3vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

I12002-003-<strong>ESXi</strong>51update.2.doc<br />

Page 14 of 35 2013-04-12


Project-Name : I12002-VM Perspecta Solutions Doc.-No. : I12002-003<br />

Doc.-Title : <strong>ESXi</strong> <strong>5.1</strong> <strong>Update</strong> Doc.-Version : 0.2<br />

net-sky2 1.20-2vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

net-vmxnet3 1.1.3.0-3vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

ohci-usb-ohci 1.0-3vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

sata-ahci 3.0-13vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

sata-ata-piix 2.12-6vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

sata-sata-nv 3.5-4vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

sata-sata-promise 2.12-3vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

sata-sata-sil24 1.1-1vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

sata-sata-sil 2.3-4vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

sata-sata-svw 2.3-3vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

scsi-aacraid 1.1.<strong>5.1</strong>-9vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

scsi-adp94xx 1.0.8.12-6vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

scsi-aic79xx 3.1-5vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

scsi-fnic 1.5.0.3-1vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

scsi-ips 7.12.05-4vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

scsi-megaraid-mbox 2.20.<strong>5.1</strong>-6vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

scsi-megaraid-sas 5.34-4vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

scsi-megaraid2 2.00.4-9vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

scsi-mptsas 4.23.01.00-6vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

scsi-mptspi 4.23.01.00-6vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

scsi-rste 2.0.2.0088-1vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

uhci-usb-uhci 1.0-3vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

tools-light <strong>5.1</strong>.0-0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

scsi-qla2xxx 934.5.6.0-1OEM.500.0.0.472560 qlogic <strong>VMware</strong>Certified 2013-04-05<br />

~ #<br />

I12002-003-<strong>ESXi</strong>51update.2.doc<br />

Page 15 of 35 2013-04-12


Project-Name : I12002-VM Perspecta Solutions Doc.-No. : I12002-003<br />

Doc.-Title : <strong>ESXi</strong> <strong>5.1</strong> <strong>Update</strong> Doc.-Version : 0.2<br />

6.3 Reboot RN-SV-05<br />

Konfiguration – Speicher – Smart Array : Die Warnung ist verschwunden!<br />

6.3.1 Aber: der RN-VM-Win2012 Server macht immer noch ein reboot alle paar<br />

Minuten:<br />

I12002-003-<strong>ESXi</strong>51update.2.doc<br />

Page 16 of 35 2013-04-12


Project-Name : I12002-VM Perspecta Solutions Doc.-No. : I12002-003<br />

Doc.-Title : <strong>ESXi</strong> <strong>5.1</strong> <strong>Update</strong> Doc.-Version : 0.2<br />

6.3.2 Und die WinXP Server können nach wie vor nicht hoch gefahren werden,<br />

Fehlermeldung unverändert wie vorher:<br />

6.4 Neuer Eintrag in Community Diskussion Upgrading <strong>ESXi</strong> 5.0 to<br />

<strong>ESXi</strong> <strong>5.1</strong> HP Smart Array P410i Warning<br />

3. 12.04.2013 07:32 als Antwort auf: peove<br />

Re: Upgrading <strong>ESXi</strong> 5.0 to <strong>ESXi</strong> <strong>5.1</strong> HP Smart Array P410i Warning<br />

6.5 Brack Tech Support Hotline<br />

6.6 HP business Support<br />

Problem bekannt und in Bearbeitung.<br />

Empfehlung für Workaround: install the HP <strong>ESXi</strong> Complete Bundle 1.5<br />

Wurde aber zurückgezogen -> Install bundle 1.4<br />

http://h18004.www1.hp.com/products/servers/software/vmware-esxi/driver_version.html<br />

6.6.1.1 Issue<br />

If customer used the old HP Image before the 09.02.2013 and applied the HP <strong>ESXi</strong> 5.0 Complete Bundle<br />

1.6 or used the latest HP Customer ISO Image of the <strong>5.1</strong> for installation/upgrade after the<br />

09.02.2013 the issue will appear.<br />

6.6.1.2 (recommended) Solution<br />

There is only an workaround so far is to run the commands:<br />

~ # esxcli software vib list | grep -i hp<br />

char-hpcru 5.0.3.09-1OEM.500.0.0.434156 Hewlett-Packard PartnerSupported 2013-01-30<br />

char-hpilo 500.9.0.0.9-1OEM.500.0.0.434156 Hewlett-Packard PartnerSupported 2013-01-30<br />

hp-ams 500.9.3.0-13.434156 Hewlett-Packard PartnerSupported 2013-02-20<br />

hp-build 5.30.28-434156 Hewlett-Packard PartnerSupported 2012-10-02<br />

hp-esx-license 1.0-05 Hewlett-Packard PartnerSupported 2012-10-02<br />

hp-smx-provider 500.03.02.00.23-434156 Hewlett-Packard <strong>VMware</strong>Accepted 2013-02-20<br />

hpacucli 9.40-12.0 Hewlett-Packard PartnerSupported 2013-02-20<br />

I12002-003-<strong>ESXi</strong>51update.2.doc<br />

Page 17 of 35 2013-04-12


Project-Name : I12002-VM Perspecta Solutions Doc.-No. : I12002-003<br />

Doc.-Title : <strong>ESXi</strong> <strong>5.1</strong> <strong>Update</strong> Doc.-Version : 0.2<br />

hpbootcfg 01-01.02 Hewlett-Packard PartnerSupported 2013-01-30<br />

hponcfg 04-00.10 Hewlett-Packard PartnerSupported 2013-01-30<br />

scsi-hpsa 5.0.0-28OEM.500.0.0.472560 Hewlett-Packard <strong>VMware</strong>Certified 2012-10-02<br />

scsi-hpvsa 5.0.0-36OEM.500.0.0.472560 Hewlett-Packard PartnerSupported 2012-10-02<br />

vmware-esx-hp_vaaip_p2000 2.1.0-2 Hewlett-Packard <strong>VMware</strong>Accepted 2012-10-02<br />

ata-pata-hpt3x2n 0.3.4-3vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2012-10-02<br />

hpnmi 2.0.11-434156 hp PartnerSupported 2013-01-30<br />

~ # esxcli software vib remove -n char-hpcru --no-live-install<br />

Removal Result<br />

Message: The update completed successfully, but the system needs to be rebooted for the changes to be<br />

effective.<br />

Reboot Required: true<br />

VIBs Installed:<br />

VIBs Removed: Hewlett-Packard_bootbank_char-hpcru_5.0.3.09-1OEM.500.0.0.434156<br />

VIBs Skipped:<br />

~ # esxcli software vib remove -n char-hpilo --no-live-install<br />

Removal Result<br />

Message: The update completed successfully, but the system needs to be rebooted for the changes to be<br />

effective.<br />

Reboot Required: true<br />

VIBs Installed:<br />

VIBs Removed: Hewlett-Packard_bootbank_char-hpilo_500.9.0.0.9-1OEM.500.0.0.434156<br />

VIBs Skipped:<br />

~ # esxcli software vib remove -n hp-ams --no-live-install<br />

Removal Result<br />

Message: The update completed successfully, but the system needs to be rebooted for the changes to be<br />

effective.<br />

Reboot Required: true<br />

VIBs Installed:<br />

VIBs Removed: Hewlett-Packard_bootbank_hp-ams_500.9.3.0-13.434156<br />

VIBs Skipped:<br />

~ # esxcli software vib remove -n hpacucli --no-live-install<br />

Removal Result<br />

Message: The update completed successfully, but the system needs to be rebooted for the changes to be<br />

effective.<br />

Reboot Required: true<br />

VIBs Installed:<br />

VIBs Removed: Hewlett-Packard_bootbank_hpacucli_9.40-12.0<br />

VIBs Skipped:<br />

~ # esxcli software vib remove -n hpbootcfg --no-live-install<br />

Removal Result<br />

Message: The update completed successfully, but the system needs to be rebooted for the changes to be<br />

effective.<br />

Reboot Required: true<br />

VIBs Installed:<br />

VIBs Removed: Hewlett-Packard_bootbank_hpbootcfg_01-01.02<br />

VIBs Skipped:<br />

~ # esxcli software vib remove -n hpnmi --no-live-install<br />

Removal Result<br />

Message: The update completed successfully, but the system needs to be rebooted for the changes to be<br />

effective.<br />

Reboot Required: true<br />

I12002-003-<strong>ESXi</strong>51update.2.doc<br />

Page 18 of 35 2013-04-12


Project-Name : I12002-VM Perspecta Solutions Doc.-No. : I12002-003<br />

Doc.-Title : <strong>ESXi</strong> <strong>5.1</strong> <strong>Update</strong> Doc.-Version : 0.2<br />

VIBs Installed:<br />

VIBs Removed: hp_bootbank_hpnmi_2.0.11-434156<br />

VIBs Skipped:<br />

~ # esxcli software vib remove -n hponcfg --no-live-install<br />

Removal Result<br />

Message: The update completed successfully, but the system needs to be rebooted for the changes to be<br />

effective.<br />

Reboot Required: true<br />

VIBs Installed:<br />

VIBs Removed: Hewlett-Packard_bootbank_hponcfg_04-00.10<br />

VIBs Skipped:<br />

~ # esxcli software vib remove -n hp-smx-provider --no-live-install<br />

Removal Result<br />

Message: The update completed successfully, but the system needs to be rebooted for the changes to be<br />

effective.<br />

Reboot Required: true<br />

VIBs Installed:<br />

VIBs Removed: Hewlett-Packard_bootbank_hp-smx-provider_500.03.02.00.23-434156<br />

VIBs Skipped:<br />

~ #<br />

Once this is been done, you need to install the HP <strong>ESXi</strong> Complete Bundle 1.5 and reboot.<br />

Leider scheint das Buendel 1.5 zurueckgezogen zu sein. Ich konnte nur 1.4 finden – oben rechts finden Sie es<br />

http://h18004.www1.hp.com/products/servers/software/vmware-esxi/driver_version.html<br />

Once this is been done, get the host of the maintenance mode and the status will be back green<br />

again. Currently L2 ISS investigating the issue.<br />

Asen Stoyanov<br />

Remote Support Engineer I<br />

Industry-Standard Server Support<br />

HP Customer Solution Center Sofia<br />

asens@hp.com<br />

Hewlett-Packard Company<br />

Business Park Sofia, Building 8<br />

Sofia, 1766<br />

Bulgaria<br />

I12002-003-<strong>ESXi</strong>51update.2.doc<br />

Page 19 of 35 2013-04-12


Project-Name : I12002-VM Perspecta Solutions Doc.-No. : I12002-003<br />

Doc.-Title : <strong>ESXi</strong> <strong>5.1</strong> <strong>Update</strong> Doc.-Version : 0.2<br />

6.6.1.3 Workaround execution log<br />

~ # esxcli software vib list | grep -i hp<br />

char-hpcru 5.0.2.21-1OEM.500.0.0.434156 Hewlett-Packard PartnerSupported 2013-04-12<br />

char-hpilo 500.9.0.0.9-1OEM.500.0.0.434156 Hewlett-Packard PartnerSupported 2013-04-12<br />

hp-ams 500.9.2.0-11.434156 Hewlett-Packard PartnerSupported 2013-04-12<br />

hp-build 5.34.23-434156 Hewlett-Packard PartnerSupported 2013-04-05<br />

hp-smx-provider 500.03.01.00.5-434156 Hewlett-Packard <strong>VMware</strong>Accepted 2013-04-12<br />

scsi-hpsa 5.0.0-40OEM.500.0.0.472560 Hewlett-Packard <strong>VMware</strong>Certified 2013-04-05<br />

scsi-hpvsa 5.0.0-50OEM.500.0.0.472560 Hewlett-Packard PartnerSupported 2013-04-05<br />

vmware-esx-hp_vaaip_p2000 2.1.0-2 Hewlett-Packard <strong>VMware</strong>Accepted 2013-04-05<br />

ata-pata-hpt3x2n 0.3.4-3vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

~ # esxcli software vib remove -n char-hpcru --no-live-install<br />

Removal Result<br />

Message: The update completed successfully, but the system needs to be rebooted for the changes<br />

to be effective.<br />

Reboot Required: true<br />

VIBs Installed:<br />

VIBs Removed: Hewlett-Packard_bootbank_char-hpcru_5.0.2.21-1OEM.500.0.0.434156<br />

VIBs Skipped:<br />

~ # esxcli software vib remove -n char-hpilo --no-live-install<br />

Removal Result<br />

Message: The update completed successfully, but the system needs to be rebooted for the changes<br />

to be effective.<br />

Reboot Required: true<br />

VIBs Installed:<br />

VIBs Removed: Hewlett-Packard_bootbank_char-hpilo_500.9.0.0.9-1OEM.500.0.0.434156<br />

VIBs Skipped:<br />

~ # esxcli software vib remove -n hp-ams --no-live-install<br />

Removal Result<br />

Message: The update completed successfully, but the system needs to be rebooted for the changes<br />

to be effective.<br />

Reboot Required: true<br />

VIBs Installed:<br />

VIBs Removed: Hewlett-Packard_bootbank_hp-ams_500.9.2.0-11.434156<br />

VIBs Skipped:<br />

I12002-003-<strong>ESXi</strong>51update.2.doc<br />

Page 20 of 35 2013-04-12


Project-Name : I12002-VM Perspecta Solutions Doc.-No. : I12002-003<br />

Doc.-Title : <strong>ESXi</strong> <strong>5.1</strong> <strong>Update</strong> Doc.-Version : 0.2<br />

~ # esxcli software vib remove -n hpacucli --no-live-install<br />

[NoMatchError]<br />

No VIB matching VIB search specification 'hpacucli'.<br />

Please refer to the log file for more details.<br />

schon bei Schritt 6.2.4 gelöscht!<br />

~ # esxcli software vib remove -n hpbootcfg --no-live-install<br />

[NoMatchError]<br />

No VIB matching VIB search specification 'hpbootcfg'.<br />

Please refer to the log file for more details.<br />

~ # esxcli software vib remove -n hpnmi --no-live-install<br />

[NoMatchError]<br />

No VIB matching VIB search specification 'hpnmi'.<br />

Please refer to the log file for more details.<br />

~ # esxcli software vib remove -n hponcfg --no-live-install<br />

[NoMatchError]<br />

No VIB matching VIB search specification 'hponcfg'.<br />

Please refer to the log file for more details.<br />

~ # esxcli software vib remove -n hp-smx-provider --no-live-install<br />

Removal Result<br />

Message: The update completed successfully, but the system needs to be rebooted for the changes<br />

to be effective.<br />

Reboot Required: true<br />

VIBs Installed:<br />

VIBs Removed: Hewlett-Packard_bootbank_hp-smx-provider_500.03.01.00.5-434156<br />

VIBs Skipped:<br />

~ #<br />

~ # cd /vmfs/volumes/50fdc63e-3da28ca5-2df5-e4115be23b79/HPdriverPack/hp-esxi5.0uX-bundle-1.4-16/<br />

/vmfs/volumes/50fdc63e-3da28ca5-2df5-e4115be23b79/HPdriverPack/hp-esxi5.0uX-bundle-1.4-16 # esxcli<br />

software vib install -d hp-esxi5.0uX-bundle-1.4-16.zip<br />

[MetadataDownloadError]<br />

Could not download from depot at zip:/var/log/vmware/hp-esxi5.0uX-bundle-1.4-16.zip?index.xml,<br />

skipping (('zip:/var/log/vmware/hp-esxi5.0uX-bundle-1.4-16.zip?index.xml', '', "Error extracting<br />

index.xml from /var/log/vmware/hp-esxi5.0uX-bundle-1.4-16.zip: [Errno 2] No such file or directory:<br />

'/var/log/vmware/hp-esxi5.0uX-bundle-1.4-16.zip'"))<br />

url = zip:/var/log/vmware/hp-esxi5.0uX-bundle-1.4-16.zip?index.xml<br />

Please refer to the log file for more details.<br />

nicht ins Depot Verzeichnis wechseln, dafür Pfad beim Depot mitgeben!<br />

/vmfs/volumes/50fdc63e-3da28ca5-2df5-e4115be23b79/HPdriverPack/hp-esxi5.0uX-bundle-1.4-16 # cd /<br />

~ #<br />

~ # esxcli software vib install -d /vmfs/volumes/50fdc63e-3da28ca5-2df5-e4115be23b79/HPdriverPack/-<br />

hp-esxi5.0uX-bundle-1.4-16/hp-esxi5.0uX-bundle-1.4-16.zip<br />

Installation Result<br />

Message: The update completed successfully, but the system needs to be rebooted for the changes<br />

to be effective.<br />

Reboot Required: true<br />

VIBs Installed: Hewlett-Packard_bootbank_char-hpcru_5.0.3.09-1OEM.500.0.0.434156,<br />

Hewlett-Packard_bootbank_char-hpilo_500.9.0.0.9-1OEM.500.0.0.434156,<br />

Hewlett-Packard_bootbank_hp-ams_500.9.3.0-13.434156,<br />

Hewlett-Packard_bootbank_hp-smx-provider_500.03.02.00.23-434156<br />

VIBs Removed:<br />

VIBs Skipped:<br />

~ #<br />

I12002-003-<strong>ESXi</strong>51update.2.doc<br />

Page 21 of 35 2013-04-12


Project-Name : I12002-VM Perspecta Solutions Doc.-No. : I12002-003<br />

Doc.-Title : <strong>ESXi</strong> <strong>5.1</strong> <strong>Update</strong> Doc.-Version : 0.2<br />

6.6.1.4 Zusätzlich Installation hp-nmi-2.0 - Version 500.2.0.11-434156<br />

~ # esxcli software vib install -d /vmfs/volumes/50fdc63e-3da28ca5-2df5-<br />

e4115be23b79/HPdriverPack/hp-nmi-esxi5.0-bundle-2.1-2.zip<br />

Installation Result<br />

Message: The update completed successfully, but the system needs to be rebooted for the changes<br />

to be effective.<br />

Reboot Required: true<br />

VIBs Installed: hp_bootbank_hpnmi_2.0.11-434156<br />

VIBs Removed:<br />

VIBs Skipped:<br />

~ # reboot<br />

6.6.1.5 Ergebnis<br />

Konfigurationswarnung ist wieder da!!!<br />

und keine Behebung des Disk Zugriffsproblems,<br />

I12002-003-<strong>ESXi</strong>51update.2.doc<br />

Page 22 of 35 2013-04-12


Project-Name : I12002-VM Perspecta Solutions Doc.-No. : I12002-003<br />

Doc.-Title : <strong>ESXi</strong> <strong>5.1</strong> <strong>Update</strong> Doc.-Version : 0.2<br />

6.6.2 aber nach absenden des Fehlerberichtes neuer Hinweis auf Knowledge Base<br />

(2036572)<br />

Powering on a virtual machine after upgrading to <strong>ESXi</strong> <strong>5.1</strong> fails with the error:<br />

File [VMFS volume] VM-name/VM-name.vmdk was not found (2036572)<br />

6.6.2.1 Remove hpnmi<br />

~ # esxcli software vib list | grep -i hp<br />

char-hpcru 5.0.3.09-1OEM.500.0.0.434156 Hewlett-Packard PartnerSupported 2013-04-12<br />

char-hpilo 500.9.0.0.9-1OEM.500.0.0.434156 Hewlett-Packard PartnerSupported 2013-04-12<br />

hp-ams 500.9.3.0-13.434156 Hewlett-Packard PartnerSupported 2013-04-12<br />

hp-build 5.34.23-434156 Hewlett-Packard PartnerSupported 2013-04-05<br />

hp-smx-provider 500.03.02.00.23-434156 Hewlett-Packard <strong>VMware</strong>Accepted 2013-04-12<br />

scsi-hpsa 5.0.0-40OEM.500.0.0.472560 Hewlett-Packard <strong>VMware</strong>Certified 2013-04-05<br />

scsi-hpvsa 5.0.0-50OEM.500.0.0.472560 Hewlett-Packard PartnerSupported 2013-04-05<br />

vmware-esx-hp_vaaip_p2000 2.1.0-2 Hewlett-Packard <strong>VMware</strong>Accepted 2013-04-05<br />

ata-pata-hpt3x2n 0.3.4-3vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

hpnmi 2.0.11-434156 hp PartnerSupported 2013-04-12<br />

~ # esxcli software vib remove -n hpnmi --no-live-install<br />

Removal Result<br />

Message: The update completed successfully, but the system needs to be rebooted for the changes<br />

to be effective.<br />

Reboot Required: true<br />

VIBs Installed:<br />

VIBs Removed: hp_bootbank_hpnmi_2.0.11-434156<br />

VIBs Skipped:<br />

~ # reboot<br />

VM bootfehler vorhanden<br />

Disk/Speicher Warnung immer noch vorhanden<br />

I12002-003-<strong>ESXi</strong>51update.2.doc<br />

Page 23 of 35 2013-04-12


Project-Name : I12002-VM Perspecta Solutions Doc.-No. : I12002-003<br />

Doc.-Title : <strong>ESXi</strong> <strong>5.1</strong> <strong>Update</strong> Doc.-Version : 0.2<br />

6.6.2.2 Behebung Knowledge Base issue (2036572): File [VMFS volume] VM-name/VMname.vmdk<br />

was not found<br />

3. Check if any of your virtual machine disks are of a hosted type. Hosted disks end with the -s00x.vmdk extension.<br />

I12002-003-<strong>ESXi</strong>51update.2.doc<br />

Page 24 of 35 2013-04-12


Project-Name : I12002-VM Perspecta Solutions Doc.-No. : I12002-003<br />

Doc.-Title : <strong>ESXi</strong> <strong>5.1</strong> <strong>Update</strong> Doc.-Version : 0.2<br />

To load the vmkernel multiextent module:<br />

1. Open a console to the <strong>ESXi</strong> host.<br />

2. Run this command to load the multiextent module:<br />

# vmkload_mod multiextent<br />

~ # vmkload_mod multiextent<br />

Module multiextent loaded successfully<br />

3. Check if any of your virtual machine disks are of a hosted type. Hosted disks end with the -s00x.vmdk extension.<br />

/vmfs/volumes # cd RN-SV-05.LUN1<br />

/vmfs/volumes/50fdc63e-3da28ca5-2df5-e4115be23b79 # ls<br />

HPdriverPack VM Windows XP HE-HPprobook WinXP-gigabyte template-VMs<br />

Trial-Linux VM-DOS-50 Windows XP Professional trash<br />

Trial-Win VM-Win2000 hot-VMs<br />

w7un309.pantec.local<br />

/vmfs/volumes/50fdc63e-3da28ca5-2df5-e4115be23b79 # cd Windows\ XP\ Professional/<br />

/vmfs/volumes/50fdc63e-3da28ca5-2df5-e4115be23b79/Windows XP Professional # ls<br />

Windows XP Professional-s001.vmdk Windows XP Professional.vmxf vmware-3.log<br />

Windows XP Professional.nvram autoinst.flp vmware-4.log<br />

Windows XP Professional.vmdk vmware-0.log vmware-5.log<br />

Windows XP Professional.vmsd vmware-1.log vmware.log<br />

Windows XP Professional.vmx vmware-2.log<br />

/vmfs/volumes/50fdc63e-3da28ca5-2df5-e4115be23b79/Windows XP Professional #<br />

4. Convert virtual disks in hosted format to one of the VMFS formats.<br />

To convert virtual disks in hosted format to one of the VMFS formats:<br />

a. Clone source hosted disk to a new disk using the command:<br />

# vmkfstools -i VM-name.vmdk .vmdk -d zeroedthick<br />

/vmfs/volumes/50fdc63e-3da28ca5-2df5-e4115be23b79/Windows XP Professional # vmkfstools -i Windows\<br />

XP\ Professional-s001.vmdk Windows\ XP\ Professional-nonHosted.vmdk -d zeroedthick<br />

Destination disk format: VMFS zeroedthick<br />

Cloning disk 'Windows XP Professional-s001.vmdk'...<br />

Clone: 100% done.<br />

/vmfs/volumes/50fdc63e-3da28ca5-2df5-e4115be23b79/Windows XP Professional # #<br />

/vmfs/volumes/50fdc63e-3da28ca5-2df5-e4115be23b79/Windows XP Professional # ls<br />

Windows XP Professional-nonHosted-flat.vmdk autoinst.flp<br />

Windows XP Professional-nonHosted.vmdk vmware-0.log<br />

Page 25 of 35 2013-04-12<br />

I12002-003-<strong>ESXi</strong>51update.2.doc


Project-Name : I12002-VM Perspecta Solutions Doc.-No. : I12002-003<br />

Doc.-Title : <strong>ESXi</strong> <strong>5.1</strong> <strong>Update</strong> Doc.-Version : 0.2<br />

Windows XP Professional-s001.vmdk<br />

Windows XP Professional.nvram<br />

Windows XP Professional.vmdk<br />

Windows XP Professional.vmsd<br />

Windows XP Professional.vmx<br />

Windows XP Professional.vmxf<br />

vmware-1.log<br />

vmware-2.log<br />

vmware-3.log<br />

vmware-4.log<br />

vmware-5.log<br />

vmware.log<br />

b. Delete the hosted disk after successful cloning using the command:<br />

# vmkfstools -U VM-name.vmdk<br />

/vmfs/volumes/50fdc63e-3da28ca5-2df5-e4115be23b79/Windows XP Professional # vmkfstools -U Windows\<br />

XP\ Professional-s001.vmdk<br />

/vmfs/volumes/50fdc63e-3da28ca5-2df5-e4115be23b79/Windows XP Professional # ls<br />

Windows XP Professional-nonHosted-flat.vmdk vmware-0.log<br />

Windows XP Professional-nonHosted.vmdk vmware-1.log<br />

……<br />

c. Rename the cloned VMFS type new disk to the original disk name using the command:<br />

# vmkfstools -E VM-name-new-disk.vmdk VM-name.vmdk<br />

/vmfs/volumes/50fdc63e-3da28ca5-2df5-e4115be23b79/Windows XP Professional # vmkfstools -E Windows\<br />

XP\ Professional-nonHosted.vmdk Windows\ XP\ Professional-s001.vmdk<br />

/vmfs/volumes/50fdc63e-3da28ca5-2df5-e4115be23b79/Windows XP Professional # ls<br />

Windows XP Professional-s001-flat.vmdk vmware-0.log<br />

Windows XP Professional-s001.vmdk vmware-1.log<br />

…………<br />

5. Run this command to unload the multiextent module:<br />

# vmkload_mod -u multiextent<br />

/vmfs/volumes/50fdc63e-3da28ca5-2df5-e4115be23b79/Windows XP Professional # vmkload_mod -u<br />

multiextent<br />

Module multiextent successfully unloaded<br />

How do I know which modules are loaded?<br />

To determine which modules are loaded, run this command:<br />

# esxcfg-module –l<br />

6.6.3 Downgrade again to hp-esxi5.0uX-bundle-1.3-12<br />

~ # esxcli software vib remove -n char-hpcru --no-live-install<br />

Removal Result<br />

Message: The update completed successfully, but the system needs to be rebooted for the changes<br />

to be effective.<br />

Reboot Required: true<br />

VIBs Installed:<br />

VIBs Removed: Hewlett-Packard_bootbank_char-hpcru_5.0.3.09-1OEM.500.0.0.434156<br />

VIBs Skipped:<br />

~ # esxcli software vib remove -n char-hpilo --no-live-install<br />

Removal Result<br />

Message: The update completed successfully, but the system needs to be rebooted for the changes<br />

to be effective.<br />

Reboot Required: true<br />

VIBs Installed:<br />

I12002-003-<strong>ESXi</strong>51update.2.doc<br />

Page 26 of 35 2013-04-12


Project-Name : I12002-VM Perspecta Solutions Doc.-No. : I12002-003<br />

Doc.-Title : <strong>ESXi</strong> <strong>5.1</strong> <strong>Update</strong> Doc.-Version : 0.2<br />

VIBs Removed: Hewlett-Packard_bootbank_char-hpilo_500.9.0.0.9-1OEM.500.0.0.434156<br />

VIBs Skipped:<br />

~ # esxcli software vib remove -n hp-ams --no-live-install<br />

Removal Result<br />

Message: The update completed successfully, but the system needs to be rebooted for the changes<br />

to be effective.<br />

Reboot Required: true<br />

VIBs Installed:<br />

VIBs Removed: Hewlett-Packard_bootbank_hp-ams_500.9.3.0-13.434156<br />

VIBs Skipped:<br />

~ # esxcli software vib remove -n hp-smx-provider --no-live-install<br />

Removal Result<br />

Message: The update completed successfully, but the system needs to be rebooted for the changes<br />

to be effective.<br />

Reboot Required: true<br />

VIBs Installed:<br />

VIBs Removed: Hewlett-Packard_bootbank_hp-smx-provider_500.03.02.00.23-434156<br />

VIBs Skipped:<br />

~ #<br />

~ # esxcli software vib install -d /vmfs/volumes/50fdc63e-3da28ca5-2df5-e4115be23b79/-<br />

HPdriverPack/hp-esxi5.0uX-bundle-1.3-12/hp-esxi5.0uX-bundle-1.3-12.zip<br />

Installation Result<br />

Message: The update completed successfully, but the system needs to be rebooted for the changes<br />

to be effective.<br />

Reboot Required: true<br />

VIBs Installed: Hewlett-Packard_bootbank_char-hpcru_5.0.2.21-1OEM.500.0.0.434156, Hewlett-<br />

Packard_bootbank_char-hpilo_500.9.0.0.9-1OEM.500.0.0.434156,<br />

Hewlett-Packard_bootbank_hpams_500.9.2.0-11.434156,<br />

Hewlett-Packard_bootbank_hp-smx-provider_500.03.01.00.5-434156<br />

VIBs Removed:<br />

VIBs Skipped:<br />

~ #<br />

I12002-003-<strong>ESXi</strong>51update.2.doc<br />

Page 27 of 35 2013-04-12


Project-Name : I12002-VM Perspecta Solutions Doc.-No. : I12002-003<br />

Doc.-Title : <strong>ESXi</strong> <strong>5.1</strong> <strong>Update</strong> Doc.-Version : 0.2<br />

Status Quo<br />

I12002-003-<strong>ESXi</strong>51update.2.doc<br />

Page 28 of 35 2013-04-12


Project-Name : I12002-VM Perspecta Solutions Doc.-No. : I12002-003<br />

Doc.-Title : <strong>ESXi</strong> <strong>5.1</strong> <strong>Update</strong> Doc.-Version : 0.2<br />

7 EIGENSCHAFTEN SPEICHER RESSOURCEN (VSPHERE)<br />

Warum LUN2 mit VMFS 3.54 und nicht auch mit VMFS 5.54?<br />

I12002-003-<strong>ESXi</strong>51update.2.doc<br />

Page 29 of 35 2013-04-12


Project-Name : I12002-VM Perspecta Solutions Doc.-No. : I12002-003<br />

Doc.-Title : <strong>ESXi</strong> <strong>5.1</strong> <strong>Update</strong> Doc.-Version : 0.2<br />

Die Festplatte '/vmfs/volumes/50fdc63e-3da28ca5-2df5-e4115be23b79/hot-VMs/RN-VM-<br />

Polarion/vm_WinXPpro-000004.vmdk' oder eine der Snapshot-Festplatten, auf die sie<br />

angewiesen ist, konnte nicht geöffnet werden. Das System kann die angegebene Datei nicht<br />

finden.<br />

<strong>VMware</strong> ESX kann die virtuelle Festplatte '/vmfs/volumes/50fdc63e-3da28ca5-2df5-<br />

e4115be23b79/hot-VMs/RN-VM-Polarion/vm_WinXPpro-000004.vmdk' nicht finden.<br />

/vmfs/volumes # pwd<br />

/vmfs/volumes<br />

/vmfs/volumes # ls<br />

057dee7a-0c8257d6-619d-000a4b76aa7b<br />

50fdd602-16227991-13b6-e4115be23b79<br />

RN-SV-05.LUN2<br />

50fdc627-fb6dc395-cd1c-e4115be23b79<br />

515f4541-af12018e-3479-e4115be23b78<br />

cc923b7a-e027e7fc-18ae-cd3d74114652<br />

50fdc63e-3da28ca5-2df5-e4115be23b79<br />

RN-SV-05.LUN1<br />

/vmfs/volumes # cd RN-SV-05.LUN1<br />

/vmfs/volumes/50fdc63e-3da28ca5-2df5-e4115be23b79 #<br />

# cd ../RN-SV-05.LUN2<br />

/vmfs/volumes/50fdd602-16227991-13b6-e4115be23b79 #<br />

Keine –s00x.vmdk im vSphere Browser sichtbar!<br />

Aber auf Konsole und nach download auf Backup-Client:<br />

/vmfs/volumes/50fdc63e-3da28ca5-2df5-e4115be23b79/hot-VMs/RN-VM-Claudio # ls<br />

vm_WinXPpro-000001-s001.vmdk vm_WinXPpro-0b01bc72.hlog vm_WinXPpro.vmx<br />

vm_WinXPpro-000001-s002.vmdk vm_WinXPpro-Snapshot1.vmsn vm_WinXPpro.vmxf<br />

vm_WinXPpro-000001-s003.vmdk vm_WinXPpro-Snapshot2.vmsn vmware-33.log<br />

vm_WinXPpro-000001-s004.vmdk vm_WinXPpro-s001.vmdk<br />

vmware-34.log<br />

vm_WinXPpro-000001.vmdk vm_WinXPpro-s002.vmdk vmware-35.log<br />

vm_WinXPpro-000002-s001.vmdk vm_WinXPpro-s003.vmdk<br />

vmware-36.log<br />

vm_WinXPpro-000002-s002.vmdk vm_WinXPpro-s004.vmdk<br />

vmware-37.log<br />

vm_WinXPpro-000002-s003.vmdk vm_WinXPpro.nvram<br />

vmware-38.log<br />

vm_WinXPpro-000002-s004.vmdk vm_WinXPpro.vmdk<br />

vmware.log<br />

vm_WinXPpro-000002.vmdk vm_WinXPpro.vmsd<br />

I12002-003-<strong>ESXi</strong>51update.2.doc<br />

Page 30 of 35 2013-04-12


Project-Name : I12002-VM Perspecta Solutions Doc.-No. : I12002-003<br />

Doc.-Title : <strong>ESXi</strong> <strong>5.1</strong> <strong>Update</strong> Doc.-Version : 0.2<br />

/vmfs/volumes/50fdc63e-3da28ca5-2df5-e4115be23b79/hot-VMs/RN-VM-Claudio #<br />

….<br />

I12002-003-<strong>ESXi</strong>51update.2.doc<br />

Page 31 of 35 2013-04-12


Project-Name : I12002-VM Perspecta Solutions Doc.-No. : I12002-003<br />

Doc.-Title : <strong>ESXi</strong> <strong>5.1</strong> <strong>Update</strong> Doc.-Version : 0.2<br />

8 VERSCHIEBEN DER VM’S AUF LUN2<br />

Start RN-SV-Claudio<br />

Fehler bleibt auch auf anderem LUN gleich es liegt nicht am LUN<br />

I12002-003-<strong>ESXi</strong>51update.2.doc<br />

Page 32 of 35 2013-04-12


Project-Name : I12002-VM Perspecta Solutions Doc.-No. : I12002-003<br />

Doc.-Title : <strong>ESXi</strong> <strong>5.1</strong> <strong>Update</strong> Doc.-Version : 0.2<br />

I12002-003-<strong>ESXi</strong>51update.2.doc<br />

Page 33 of 35 2013-04-12


Project-Name : I12002-VM Perspecta Solutions Doc.-No. : I12002-003<br />

Doc.-Title : <strong>ESXi</strong> <strong>5.1</strong> <strong>Update</strong> Doc.-Version : 0.2<br />

9 RECOMMENDATIONS FROM VMWARE COMMUNITY<br />

Re: Upgrading <strong>ESXi</strong> 5.0 to <strong>ESXi</strong> <strong>5.1</strong> HP Smart Array P410i Warning<br />

The latest HP Offline Bundle fixes the issues with the hardware status warning<br />

http://vibsdepot.hp.com/hpq/apr2013/<br />

http://www.jonmunday.net/2013/04/16/fix-hp-esxi-5-x-management-bundles/<br />

~ # esxcli software vib list >/vmfs/volumes/50fdc63e-3da28ca5-2df5-e4115be23b79/HPdriverPack/viblist.before.txt<br />

~ #<br />

~ # esxcli software vib install -d /vmfs/volumes/50fdc63e-3da28ca5-2df5-e4115be23b79/HPdriverPack/-<br />

hp-esxi5.0uX-bundle-1.4.5-3.zip<br />

Installation Result<br />

Message: The update completed successfully, but the system needs to be rebooted for the changes<br />

to be effective.<br />

Reboot Required: true<br />

VIBs Installed: Hewlett-Packard_bootbank_char-hpcru_5.0.3.09-1OEM.500.0.0.434156,<br />

Hewlett-Packard_bootbank_hp-ams_500.9.3.5-02.434156,<br />

Hewlett-Packard_bootbank_hp-smx-provider_500.03.02.10.4-434156<br />

I12002-003-<strong>ESXi</strong>51update.2.doc<br />

Page 34 of 35 2013-04-12


Project-Name : I12002-VM Perspecta Solutions Doc.-No. : I12002-003<br />

Doc.-Title : <strong>ESXi</strong> <strong>5.1</strong> <strong>Update</strong> Doc.-Version : 0.2<br />

VIBs Removed: Hewlett-Packard_bootbank_char-hpcru_5.0.2.21-1OEM.500.0.0.434156,<br />

Hewlett-Packard_bootbank_hp-ams_500.9.2.0-11.434156,<br />

Hewlett-Packard_bootbank_hp-smx-provider_500.03.01.00.5-434156<br />

VIBs Skipped: Hewlett-Packard_bootbank_char-hpilo_500.9.0.0.9-1OEM.500.0.0.434156<br />

~ # esxcli software vib install -d /vmfs/volumes/50fdc63e-3da28ca5-2df5-e4115be23b79/HPdriverPack/-<br />

hp-ams-esxi5.0-bundle-9.3.5-3.zip<br />

Installation Result<br />

Message: The update completed successfully, but the system needs to be rebooted for the changes<br />

to be effective.<br />

Reboot Required: true<br />

VIBs Installed: Hewlett-Packard_bootbank_hp-smx-limited_500.03.02.10.3-434156<br />

VIBs Removed: Hewlett-Packard_bootbank_hp-smx-provider_500.03.02.10.4-434156<br />

VIBs Skipped: Hewlett-Packard_bootbank_char-hpcru_5.0.3.09-1OEM.500.0.0.434156,<br />

Hewlett-Packard_bootbank_char-hpilo_500.9.0.0.9-1OEM.500.0.0.434156,<br />

Hewlett-Packard_bootbank_hp-ams_500.9.3.5-02.434156<br />

~ # reboot<br />

~ #<br />

~ # esxcli software vib list >/vmfs/volumes/50fdc63e-3da28ca5-2df5-e4115be23b79/HPdriverPack/viblist.after.txt<br />

~ #<br />

~ # esxcli software vib list | grep -i hp<br />

char-hpcru 5.0.3.09-1OEM.500.0.0.434156 Hewlett-Packard PartnerSupported 2013-04-16<br />

char-hpilo 500.9.0.0.9-1OEM.500.0.0.434156 Hewlett-Packard PartnerSupported 2013-04-12<br />

hp-ams 500.9.3.5-02.434156 Hewlett-Packard PartnerSupported 2013-04-16<br />

hp-build 5.34.23-434156 Hewlett-Packard PartnerSupported 2013-04-05<br />

hp-smx-limited 500.03.02.10.3-434156 Hewlett-Packard <strong>VMware</strong>Accepted 2013-04-16<br />

scsi-hpsa 5.0.0-40OEM.500.0.0.472560 Hewlett-Packard <strong>VMware</strong>Certified 2013-04-05<br />

scsi-hpvsa 5.0.0-50OEM.500.0.0.472560 Hewlett-Packard PartnerSupported 2013-04-05<br />

vmware-esx-hp_vaaip_p2000 2.1.0-2 Hewlett-Packard <strong>VMware</strong>Accepted 2013-04-05<br />

ata-pata-hpt3x2n 0.3.4-3vmw.510.0.0.799733 <strong>VMware</strong> <strong>VMware</strong>Certified 2013-04-05<br />

~ #<br />

keine driver Warning<br />

Aber immer noch vmdk load Problem wie vorher.<br />

I12002-003-<strong>ESXi</strong>51update.2.doc<br />

Page 35 of 35 2013-04-12

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!