Micrologic E - Schneider Electric

schneider.electric.co.za

Micrologic E - Schneider Electric

Micrologic E

The smart view to energy efficiency

Control unit for Compact NS630b to NS3200

and Masterpact NT/NW circuit breakers


Agenda

The need for accurate energy information

Micrologic E: Energy efficiency, now within your reach

Smart: The intelligent way to put energy metering where you need it

Safe: Protection, communications and metering, reliably in one device

Simple: Connect energy information to everyone that needs it

Next steps toward energy efficiency

Schneider Electric Power Micrologic E January 2011

2


Buildings can achieve

up to 30% energy

savings with an Active

Energy Management

program that includes

an energy metering

system.

Schneider Electric Power Micrologic E January 2011

3


The need for energy information

Energy costs are increasing

More stringent greenhouse gas

emissions regulations

Need to reduce energy consumption

The first step is energy metering:

> Reveal where, when, how much energy

is consumed

> Discover opportunities to improve

your efficiency

Schneider Electric Power Micrologic E January 2011

4


Introducing Micrologic E

Control unit for circuit breakers:

Compact NS630b to NS3200

Masterpact NT/NW

Includes embedded energy metering capability

Most affordable way to help:

> Maximize efficiency

> Control costs

> Meet environmental objectives

& responsibilities

Schneider Electric Power Micrologic E January 2011

5


Smart

The intelligent way to put energy

metering where you need it

Schneider Electric Power Micrologic E January 2011

6


Smart – the new industry standard

Compact NSX circuit breaker was the first to

offer cost-effective, embedded energy metering

Micrologic E extends this across Compact NS and

Masterpact NT/NW ranges

Schneider Electric Power Micrologic E January 2011

7


Smart – the most affordable choice

You get an energy meter in

every breaker

Avoids the costs and panel space

of installing a separate power

meter with current transformers

Schneider Electric Power Micrologic E January 2011

8


Smart – bridging the gap

No Metering A 'ammeter' E 'energy' P 'power' H 'harmonics'

Current, maximeter

Measurement

Voltage, PF, power, demand, energy*

Cos-, frequency, per phase,

advanced protection

Harmonics, waveform capture,

enhanced alarms

2 (L, I)

2.0

2.0 A

2.0 E

Protection

5 (L, S, I)

6 (L, S, I, G)

5.0

6.0

5.0 A

6.0 A

5.0 E

6.0 E

5.0 P

6.0 P

5.0 H

6.0 H

7 (L, S, I, V)

7.0 A

7.0 P

7.0 H

Schneider Electric Power Micrologic E January 2011

9


Smart – high value, low cost

Compared to popular Micrologic A:

Same integrated LCD

Same ease-of-use

Same reliability

For only a small incremental cost,

Micrologic E also gives you:

> Energy metering

> Some additional features of the model P

Schneider Electric Power Micrologic E January 2011

10


Smart – wide range of applications

The energy data from Micrologic E will improve efficiency

by helping you:

Study consumption patterns

Compare the performance

of different facilities

Isolate where energy

is being wasted

Expose energy costs at

the building, department

or machine level

Validate utility billing

and verify energy on

feeders matches sum

of tenant meters

Schneider Electric Power Micrologic E January 2011

11


Safe

Protection, communications and

metering, reliably in one device

Schneider Electric Power Micrologic E January 2011

12


Safe – a unique, reliable architecture

You must trust your circuit breakers to protect people and equipment

Micrologic E has a unique architecture:

> Protection operates independently of measurement

and communication

> All functions are tested and certified together

This guarantees the quality and reliability of all functions

Schneider Electric Power Micrologic E January 2011

13


Safe – a unique, reliable architecture

Protection

Metering

ASIC

Microprocessor

Communication

Module

Air CT

Basic protection

functions

Separation

Advanced protection

functions

(metering, analyses…)

Optical

Link

Iron CT

Current-dependent

power supply

Power supply

Sensors &

Power Source

Processing

Communications

Schneider Electric Power Micrologic E January 2011

14


Safe - Automatic Scroll Quick View

Personnel do not have to touch the

front panel to access data

Automatically advances through all

the most relevant measurements

New, innovative display mode

Schneider Electric Power Micrologic E January 2011

15


Safe – more features, more flexibility

Two additional features previously only available in models P & H

Trip History for easy troubleshooting:

Last 10 trips memorized in

non-volatile memory

Viewable through LCD or software

Includes trip cause &

date/timestamp

Two relay outputs for

coordinated control:

M2C type relays,

driven by trip events

Use for management

functions

Schneider Electric Power Micrologic E January 2011

16


Simple

Connect energy information to

everyone that needs it

Schneider Electric Power Micrologic E January 2011

17


Simple – convenient, local data access

New BCM ULP communication

module option

Connect FDM121 display to Compact

or Masterpact circuit breaker

High-visibility data access from

electrical cabinet front panel:

> All Micrologic measurements and histories

> Circuit breaker maintenance indicators

Schneider Electric Power Micrologic E January 2011


Simple – a building-wide network

BCM ULP allows standard plug-and-play connectivity

Enables remote access

to energy data from Micrologic E

Create a communication network:

Circuit breakers, relays,

power meters, other devices

Web-enabled gateways or RTUs

Laptops and desktop PCs

Schneider Electric Power Micrologic E January 2011

19


Simple – data delivered to your desktop

Information easily accessible

to anyone that needs it

Facility and corporate

managers analyze energy

efficiency and costs

Maintenance personnel

analyze electrical system

reliability and perform

remote maintenance and

troubleshooting

View data for further analysis

using standard web browsers

or user-friendly software

Schneider Electric Power Micrologic E January 2011

20


Remote Control Utility (RCU)

Free utility for simple

data access and

circuit breaker control

Schneider Electric Power Micrologic E January 2011

21


iRIO RTU or EGX300 gateway

On-board web servers deliver

real-time and historical data

Schneider Electric Power Micrologic E January 2011

22


PowerLogic ION Enterprise software

Advanced energy and

power quality analysis

Schneider Electric Power Micrologic E January 2011

23


Thinking ahead

Micrologic E control unit in every

circuit breaker is an important first

step toward energy efficiency

Schneider Electric can help you

achieve maximum efficiency

across your entire building

Delivering up to 30% energy savings

in industrial and commercial buildings

Schneider Electric Power Micrologic E January 2011

25


Active Energy Management

Integrated strategy from Power Plant to Plug

Schneider Electric Power Micrologic E January 2011

26


Ecostruxure architecture

Intelligent energy management

systems that:

Guarantee compatibility between the

management of power, process and

machines, IT rooms, buildings, and

security

This ensures systems are simplified,

save money and reduce waste

Schneider Electric Power Micrologic E January 2011

27


Make the most

of your energy

More magazines by this user
Similar magazines