<strong>Model</strong>: <strong>PLFY</strong>-<strong>P36NBMU</strong>-E<br />

Job Name:<br />

Location:<br />

Drawing Reference:<br />

Schedule No.<br />

System No.:<br />

Date:<br />

Net Weight<br />

Unit………………..…...……………..................60 lbs. / 27 kg<br />

Grille………………..…...…………….................. 13 lbs. / 6 kg<br />

Coil Type………………...........................................….Cross Fin<br />

(Aluminum Plate Fin and Copper Tube)<br />

Fan<br />

Type x Quantity………………..………….........…........... Trubo fan x1<br />

Airflow Rate (Low-Mid2-Mid1-High).... 777 - 883 - 989 - 1,059 CFM<br />

GENERAL FEATURES<br />

• R410A refrigerant<br />

• Lightweight, low-profile compact desgin<br />

• Six sizes from 12,000 to 36,000 Btu/h<br />

• Corner-pocket desgin for simplified installation<br />

• Built-in condensate lift mechanism; lifts to 33-1/2 in.<br />

• Four-speed fan setting and auto fan speed adjsument mode<br />

• Outside air capability<br />

• Quiet operation from 29 to 43 dB(A)<br />

• i-see sensor option uses infrared rays to search for hot and<br />

cold spots<br />

SPECIFICATIONS<br />

Capacity*<br />

Cooling…………………………………………….… 36,000 Btu/h<br />

Heating…………………………………………….… 40,000 Btu/h<br />

Power<br />

Power Source………………..........208 / 230V, 1-phase, 60Hz<br />

Power Consumption<br />

Cooling…………………………………………….………0.16 kW<br />

Heating…………………………………………….………0.15 kW<br />

Current<br />

Cooling……...................................................……………1.07 A<br />

Heating……...................................................……………1.00 A<br />

Minimum Circuit Ampacity (MCA)……………….…..……... 1.25 A<br />

Maximum Overcurrent Protection (MOCP) Fuse..….......…..15 A<br />

External Finish……..... Grille (White; Munsell No. 6.4Y 8.9 / 0.4)<br />

Unit Dimensions<br />

<strong>Inc</strong>hes……………………...... 11-3/4 H x 33-3/32 W x 33-3/32 D<br />

mm……………………………………... 298 H x 840 W x 840 D<br />

Grille Dimensions<br />

<strong>Inc</strong>hes…………………..... 1-3/8 H x 37-13/32 W x 37-13/32 D<br />

mm…………………………………... 35 H x 950 W x 950 D<br />

Motor<br />

Type………..………..………...........................…… DC Motor<br />

Output………..………..………..………..………..….0.120 kW<br />

Air Filter..…………………………….Polypropylene Honeycomb<br />

Refrigerant Piping Dimensions<br />

Liquid (High Pressure)……............3/8" / 9.52 mm (Flared)<br />

Gas (Low Pressure)………………..5/8" / 15.88 mm (Flared)<br />

Drainpipe Dimension……............……...…O.D. 1-1/4" / 32 mm<br />

Sound Pressure Levels<br />

Low-Mid2-Mid1-High….…………… ……….<br />

35 - 38 - 41 - 43 dB(A)<br />

OPTIONS<br />

□ External Heat Adaptor................................... PAC-YU25HT<br />

□ Air Shutter Plate (2 Pieces).......................... PAC-SH51SP-E<br />

□ High Efficiency Filter (Merv 10).................... PAC-SH59KF-E<br />

□ Multi Funcation Casement............................ PAC-SH53TM-E<br />

□ i-see Sensor Corner Panel........................... PAC-SA1ME-E<br />

□ Flange for Fresh Air Intake........................... PAC-SH65OF-E<br />

□ Wirelesee Signal Receiver............................ PAC-SF9A-E<br />

* Cooling / Heating capacity indicated at the maximum value at<br />

operation under the following conditions:<br />

Cooling: Indoor 80°F (27°C) DB / 67°F (19°C) WB, Outdoor 95°F<br />

(35°C) DB<br />

Heating: Indoor 70°F (21°C) DB, Outdoor 47°F (8°C) DB / 43°F (6°C)<br />

WB<br />

Note: Ventilation air: Providing suf ficient ventilation air is an important<br />

part of every building design. ASHRAE Standard 62 provides<br />

the minimum ventilation air requirement. Also, check local codes.<br />

Notes:


6-11/16<br />

(170)<br />

6-5/16<br />

(160)<br />

(90)<br />

(150)<br />

3-17/32<br />

5-1/2<br />

(140)<br />

1-31/32 to 2-3/4<br />

(50~70)<br />

For MA-Remote controller<br />

terminal block<br />

<strong>Model</strong>: <strong>PLFY</strong>-<strong>P36NBMU</strong>-E – DIMENSIONS<br />

Ceiling hole<br />

25/32~1-25/32(20~45) 33-27/32 to 35-13/16(860~910) 25/32 to 1-25/32(20~45)<br />

31-7/8(810)<br />

Fresh air<br />

intake hole 6-16/5<br />

Suspension bolt pitch<br />

(160)<br />

33-1/16(840)<br />

Branch duct hole<br />

5-29/32<br />

C<br />

D<br />

Suspension bolt<br />

M10 or W3/8<br />

1<br />

2<br />

Suspension bolt<br />

lower edge<br />

7-3/8<br />

6-5/16<br />

(187.5)<br />

33-1/16(840)<br />

(160)<br />

(60) (284)<br />

(377)<br />

2-3/8 11-3/16 14-27/32<br />

M<br />

Indoor unit/Outdoor unit<br />

connecting terminal block<br />

23-1/2(597)<br />

Air intake hole<br />

(5/16)<br />

(7.5)<br />

1-25/32<br />

(20~45)<br />

4-1/8(105)<br />

15/16 (24)<br />

6-9/64<br />

(156)<br />

6-5/16 (160) Suspension bolt pitch<br />

7-15/32<br />

(5/16) 23-13/16 +35<br />

(605 -5 )<br />

-3/16<br />

+5 (17 0 )<br />

(190)<br />

+3/16<br />

11/16<br />

0<br />

A<br />

(7.5)<br />

+1-3/8 24-13/32<br />

(620)<br />

1-3/8<br />

B<br />

25/32<br />

33-27/32 to 35-13/16(860~910)<br />

(35)<br />

Ceiling hole<br />

Ceiling<br />

Grille<br />

25/32 to<br />

to 1-25/32<br />

(20~45)<br />

Drain pipe<br />

connected to VP-25<br />

Drain hole<br />

Drain pump clean hole<br />

and Drain emergency<br />

drainage hole<br />

Branch<br />

duct hole<br />

( 175) 6-7/8<br />

Connected the attached<br />

flexible pipe or socket.<br />

Keep 25/64(10) to 19/32(15)<br />

between unit ceiling<br />

and ceiling slab.<br />

Detail connecting of branch duct(Both aspects)<br />

3-15/16 (100)<br />

3-15/16(100)<br />

3-17/32 (90)<br />

3-17/32(90)<br />

Cut out hole<br />

70<br />

Burring hole pitch<br />

In case of standard grille<br />

( 158)<br />

6-7/32<br />

13-25/32<br />

(350)<br />

Burring hole<br />

3- 1/8(3- 2.8)<br />

5-29/32( 150)<br />

Cut out hole<br />

Ceiling<br />

3-15/16 (100)<br />

5-1/8 (130)<br />

14- 1/8(14- 2.8)<br />

Burring hole<br />

Detail drawing of fresh air intake hole<br />

) (<br />

Receiver<br />

120<br />

120<br />

Burring hole pitch<br />

4-29/32( 125)<br />

Cut out hole<br />

3-15/16( 100)<br />

In case of wireless remote controller<br />

Emergency operation switch<br />

Emergency operation<br />

switch<br />

*6-3/32(155)<br />

*6-9/16(167)<br />

Units: in.(mm)<br />

M<br />

Auto vane<br />

(Air outlet)<br />

Operation lamp<br />

DEFROST/STAND BY lamp<br />

(950)<br />

37-3/8<br />

Air intake<br />

grille<br />

19-11/16 (500)<br />

Air outlet hole<br />

3-17/64<br />

(83)<br />

1-27/64<br />

(36)<br />

M<br />

Corner pocket<br />

Indoor unit<br />

19-11/16 (500)<br />

Air outlet hole<br />

37-3/8 (950)<br />

M<br />

3-17/64<br />

(83)<br />

23-1/2 (597)<br />

Air intake hole<br />

Vane motor<br />

1-27/64(36)<br />

Note:<br />

1. As for drain pipe, please use VP-25 O.D. 1-1/4(32) PVC TUBE.<br />

Drain pump is included.<br />

Max. lifting height is 70-7/18 (850mm) from the ceiling.<br />

2. As for suspension bolt, please use M10 or W3/8. (Procured at local site)<br />

3. <strong>Electric</strong>al box may be removed for the service purpose.<br />

Make sure to slack the electrical wire little bit for control/power wires connection.<br />

4. The height of the indoor unit is able to be adjusted with the grille attached.<br />

5. For the installation of the optional high efficiency filter or optional multi-functional<br />

casement.<br />

1 Add 5-5/16"(135mm) to the dimensions marked on the figure.<br />

2 The optional high efficiency filter becomes optional multi-functional casement<br />

and concomitant use.<br />

6. When installing the branch ducts, be sure to insulate adequately.<br />

Otherwise condensation and dripping may occur.<br />

(It becomes the cause of dew drops/water dew.)<br />

As for necessary installation / service space, please refer to the left figure.<br />

Accessory•••Drain socket(I.D.1-1/4)<br />

Ceiling<br />

Grille<br />

Entire<br />

periphery<br />

Min.19-11/16(500)<br />

Min.94-1/2(2400)<br />

from floor<br />

Floor<br />

<strong>Model</strong>s<br />

<strong>PLFY</strong>-P12NBMU-E<br />

<strong>PLFY</strong>-P15NBMU-E<br />

<strong>PLFY</strong>-P18NBMU-E<br />

<strong>PLFY</strong>-P24NBMU-E<br />

<strong>PLFY</strong>-P30NBMU-E<br />

<strong>PLFY</strong>-<strong>P36NBMU</strong>-E<br />

1 2<br />

Refrigerant pipe<br />

... 6.35<br />

Flared connection<br />

... 1/4<br />

Refrigerant pipe<br />

6.35 / 9.52<br />

Flared connection<br />

1/4 / 3/8<br />

(compatible)<br />

Refrigerant pipe<br />

... 9.52<br />

Flared connection<br />

... 3/8<br />

Refrigerant pipe ... 12.7<br />

Flared connection ... 1/2<br />

Refrigerant pipe 12.7 / 15.88<br />

Flared connection 1/2 / 5/8<br />

(compatible)<br />

Refrigerant pipe ... 15.88<br />

Flared connection ... 5/8<br />

Refrigerant pipe 15.88 / 19.05<br />

Flared connection 5/8 / 3/4<br />

(compatible)<br />

A B C D<br />

9-1/2 10-3/16 3-5/32 2-29/32<br />

(241) (258) (80) (74)<br />

11-1/16<br />

(281)<br />

11-3/4 3-11/32<br />

(298) (85)<br />

3-1/32<br />

(77)<br />

<strong>Mitsubishi</strong> <strong>Electric</strong> Air Conditioning & Refrigeration Systems Wo rks acquired ISO<br />

based on a review of quality warranties for the production of refrigeration and air<br />

conditioning equipment.<br />

ISO Authorization System<br />

The ISO 9000 series is a plant authorization system relating to quality warranties as<br />

development, production, installation and auxiliary services" for products built at<br />

an authorized plant.<br />

<strong>Mitsubishi</strong> <strong>Electric</strong> <strong>Sales</strong> <strong>Canada</strong> <strong>Inc</strong>.<br />

www.<strong>Mitsubishi</strong><strong>Electric</strong>.ca<br />

<strong>Mitsubishi</strong> <strong>Electric</strong> Air Conditioning & Refrigeration Systems Works acquired environmental<br />

The ISO 14000 series is a set of standards applying to environmental protection set by the<br />

International Standard Organization (ISO).<br />

Specifications are subject to change without notice.<br />

SB_<strong>PLFY</strong>-<strong>P36NBMU</strong>-E_201005b