GAS SAMPLING SYSTEM - ancb.it
GAS SAMPLING SYSTEM - ancb.it
GAS SAMPLING SYSTEM - ancb.it
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>GAS</strong> <strong>SAMPLING</strong> <strong>SYSTEM</strong><br />
FOR WET AND DRY SPACES<br />
The Gas Sampling System is intended for the<br />
detection of flammable and toxic gases in<br />
various zones of the vessel, including ballast<br />
tanks, void spaces, pump room, compressor<br />
rooms, motor rooms and forecastle. A<br />
diaphragm pumps is used to draw samples from<br />
the dangerous areas to the analyser.<br />
Samples are taken sequentially from the single<br />
measuring point and sent to a Dräger Polytron®<br />
catalytic sensor.<br />
The system can be optionally configured to<br />
detect up to 100% volume of hydrocarbons by<br />
means of an Infrared sensor, and for Hydrogen<br />
Sulphide and/or Oxygen detection by means of<br />
electrochemical sensors.<br />
The standard Control Un<strong>it</strong> is a<br />
HMI (Human-Machine Interface)<br />
device w<strong>it</strong>h graphic LCD display and touch screen function.<br />
The graphic display shows all the main operating information, such as channel number,<br />
channel defin<strong>it</strong>ion, system status and gas level reading in clear-text.<br />
It is possible to install an extended control un<strong>it</strong> featuring up to 15” LCD display.
Main features and functions:<br />
Sampling system and piping enclosed into a gas tight<br />
cabinet<br />
220VAC main voltage supply<br />
Graphic Operator Terminal as main standard Control Un<strong>it</strong><br />
Alphanumeric Operator Terminal as standard Repeater<br />
Un<strong>it</strong><br />
Programmable Logic Controller (PLC)<br />
Manual / Automatic Tank lines scanning<br />
%L.E.L. measuring and displaying w<strong>it</strong>h set point check<br />
Gas alarms displaying and acknowledgement<br />
Two gas alarm levels<br />
Gas detector(s) failure alarm(s)<br />
High flow rate sampling pump<br />
Auto test at start-up<br />
Flow Fault alarm<br />
Pipelines purging feature<br />
Sensor cleaning/zeroing feature<br />
Gas detector(s) calibration facil<strong>it</strong>y w<strong>it</strong>h dedicated<br />
external gas inlet su<strong>it</strong>able for disposable bottles<br />
Disconnection of wet sampling points<br />
Individual scan rate setting<br />
Dedicated sampling point for internal leakage detection<br />
End-of-Line cones w<strong>it</strong>h non-return valve for wet spaces<br />
End-of-Line cones w<strong>it</strong>h filter element for dry spaces<br />
OPTIONS:<br />
Sampling Un<strong>it</strong> separated from Control Un<strong>it</strong><br />
Extended or Special type graphic Operator Terminal<br />
Event printer<br />
Hydrogen Sulphide (H2S) measurement<br />
Oxygen (O2) Measurement<br />
IR sensor for hydrocarbons volume measurement<br />
Counter-pressure on sampling lines<br />
Pre-suction pump to reduce the total scan time<br />
Cabinet special painting<br />
System customization<br />
A.N.C.B.sas<br />
Via Molo Giano<br />
16128 – Genova Porto<br />
ITALY<br />
Pho.+39 010 2510784 Fax.+39 010 2510785<br />
Email: info@<strong>ancb</strong>.<strong>it</strong> Webs<strong>it</strong>e: www.<strong>ancb</strong>.<strong>it</strong>