C<strong>on</strong>tents<br />

3 Introducti<strong>on</strong><br />

<str<strong>on</strong>g>Quantel</str<strong>on</strong>g>, <strong>on</strong> <strong>the</strong> <strong>cutting</strong> <strong>edge</strong> <strong>of</strong> <strong>new</strong> <strong>laser</strong> <strong>technologies</strong><br />

4 Pulsed Nd:YAG Laser Oscillators<br />

8 Multi-Pulse Lasers<br />

9 Modular Lasers<br />

11 Tunable Lasers<br />

12 Nd:Glass Laser Systems<br />

13 Custom-Built Laser Soluti<strong>on</strong>s and Engineering Services<br />

14 OEM Soluti<strong>on</strong>s<br />

15 Military and Aerospace Laser Soluti<strong>on</strong>s<br />

<str<strong>on</strong>g>Quantel</str<strong>on</strong>g> was founded in 1970 and since <strong>the</strong>n has built up a first-rate worldwide<br />

reputati<strong>on</strong> in <strong>the</strong> field <strong>of</strong> solid-state <strong>laser</strong>s. The corporate headquarters <strong>of</strong><br />

<str<strong>on</strong>g>Quantel</str<strong>on</strong>g> is located in Les Ulis, France, near Paris.<br />

The <str<strong>on</strong>g>Quantel</str<strong>on</strong>g> group is <strong>the</strong> leader in <strong>the</strong> rapidly advancing field <strong>of</strong> <strong>laser</strong> technology and we c<strong>on</strong>tinuously<br />

bring to you <strong>new</strong> products and <strong>new</strong> <strong>technologies</strong> as we have been doing for <strong>the</strong> past 37 years.<br />

At <str<strong>on</strong>g>Quantel</str<strong>on</strong>g> we design, manufacture, and market advanced flash-lamp pumped <strong>laser</strong>s, diode-pumped solidstate<br />

<strong>laser</strong>s, intense pulsed light instruments, ultra-sound diagnostic products, and fiber-<strong>laser</strong> soluti<strong>on</strong>s for<br />

a variety <strong>of</strong> industrial, scientific, medical, military, and aerospace applicati<strong>on</strong>s.<br />

The <str<strong>on</strong>g>Quantel</str<strong>on</strong>g> group invests heavily in research and development and this has led to <strong>the</strong> introducti<strong>on</strong> <strong>of</strong><br />

numerous innovative and successful <strong>new</strong> products. The Industrial and Scientific Laser group <strong>of</strong> <str<strong>on</strong>g>Quantel</str<strong>on</strong>g><br />

focuses <strong>on</strong> <strong>the</strong> development <strong>of</strong> industrial and scientific <strong>laser</strong> products while <strong>the</strong> <str<strong>on</strong>g>Quantel</str<strong>on</strong>g> Medical group is<br />

entirely dedicated to <strong>the</strong> development <strong>of</strong> advanced <strong>laser</strong> products and soluti<strong>on</strong>s with applicati<strong>on</strong>s in <strong>the</strong><br />

medical field.<br />

<str<strong>on</strong>g>Quantel</str<strong>on</strong>g> is an internati<strong>on</strong>al company with subsidiaries in <strong>the</strong> USA which include <str<strong>on</strong>g>Quantel</str<strong>on</strong>g> USA, previously<br />

known as Big Sky Laser Technologies, Inc. The o<strong>the</strong>r subsidiary <strong>of</strong> <str<strong>on</strong>g>Quantel</str<strong>on</strong>g> in <strong>the</strong> USA is <str<strong>on</strong>g>Quantel</str<strong>on</strong>g> Medical, Inc.<br />

which is dedicated to <strong>the</strong> <strong>of</strong>fering <strong>of</strong> <strong>laser</strong> and ultra sound soluti<strong>on</strong>s to <strong>the</strong> medical field in <strong>the</strong> USA.<br />

Big Sky Laser Technologies was founded in 1982 and is located in Bozeman, M<strong>on</strong>tana, USA. This subsidiary<br />

<strong>of</strong> <str<strong>on</strong>g>Quantel</str<strong>on</strong>g> changed its name to <str<strong>on</strong>g>Quantel</str<strong>on</strong>g> USA in 2007 and c<strong>on</strong>tinues to be dedicated to <strong>the</strong> design and<br />

manufacturing <strong>of</strong> compact and rugged Nd:YAG <strong>laser</strong>s, and o<strong>the</strong>r pulsed solid-state <strong>laser</strong>s, which are<br />

designed for demanding real-world industrial, medical, and military applicati<strong>on</strong>s.<br />

In 2007 <str<strong>on</strong>g>Quantel</str<strong>on</strong>g> acquired Wavelight Aes<strong>the</strong>tic GmbH in Germany which specializes in <strong>laser</strong>s with<br />

applicati<strong>on</strong>s in <strong>the</strong> field <strong>of</strong> dermatology. The combinati<strong>on</strong> <strong>of</strong> <str<strong>on</strong>g>Quantel</str<strong>on</strong>g>’s dermatology related medical<br />

activities and products with those <strong>of</strong> Wavelight Aes<strong>the</strong>tic has resulted in an excepti<strong>on</strong>ally str<strong>on</strong>g medical<br />

product portfolio which fur<strong>the</strong>r streng<strong>the</strong>ns <strong>the</strong> positi<strong>on</strong> <strong>of</strong> <str<strong>on</strong>g>Quantel</str<strong>on</strong>g> as a leading worldwide supplier <strong>of</strong><br />

<strong>laser</strong> products to <strong>the</strong> medical field.<br />

Throughout our 37 years <strong>of</strong> history in <strong>the</strong> <strong>laser</strong> industry customer satisfacti<strong>on</strong> and product quality have<br />

always been our organizati<strong>on</strong>’s primary objectives. Our company is ISO 9001:2000 certified.<br />

Whe<strong>the</strong>r you need a pulsed <strong>laser</strong> for scientific applicati<strong>on</strong>s or a tough and compact rugged industrial <strong>laser</strong><br />

built to military standards we provide you with <strong>the</strong> highest quality soluti<strong>on</strong>s that best match your needs.<br />

Customer satisfacti<strong>on</strong> through <strong>of</strong>fering <strong>of</strong> <strong>the</strong> highest quality products and services is a commitment to<br />

which every employee <strong>of</strong> <strong>the</strong> global <str<strong>on</strong>g>Quantel</str<strong>on</strong>g> team is fully dedicated.<br />

For more informati<strong>on</strong> <strong>on</strong> <str<strong>on</strong>g>Quantel</str<strong>on</strong>g> and our products visit our website at www.quantel-<strong>laser</strong>.com<br />

2-3<br />

www.quantel-<strong>laser</strong>.com


CFR and ULTRA<br />

Brio<br />

Pulsed Nd:YAG Laser Oscillators<br />

Model Ultra20 Ultra50 Ultra100 CFR200 CFR300 CFR400<br />

Repetiti<strong>on</strong> Frequency (Hz) ≤50 ≤20 ≤20 ≤100 ≤20 ≤30<br />

Energy (mJ) at 20 Hz 1064 nm 20 50 100 200 300 400<br />

532 nm 12 30 55 130 200 230<br />

355 nm 2.5 12 30 70 90 90<br />

266 nm 2.5 10 25 50 40<br />

1.57 µm 1.5 8 25 65 65<br />

Pulse durati<strong>on</strong> (ns) 11 8 8 8 8 9<br />

Dimensi<strong>on</strong>s (LxWxH, mm) Laser head 203x76x51 323x94x84<br />

Res<strong>on</strong>ator type<br />

Repetiti<strong>on</strong> rate (Hz)<br />

The CFR and <strong>the</strong> ULTRA <strong>laser</strong>s are two different models in our Big Sky Laser family <strong>of</strong> products. The<br />

Big Sky Laser product line <strong>of</strong>fers you tough, compact, and envir<strong>on</strong>mentally sealed systems which are<br />

manufactured and tested to military standards. These <strong>laser</strong>s are built based <strong>on</strong> our Compact Folded<br />

Res<strong>on</strong>ator (CFR) technology which we have developed for highly demanding industrial applicati<strong>on</strong>s<br />

in <strong>the</strong> most hostile envir<strong>on</strong>ments. The mechanical housings <strong>of</strong> <strong>the</strong>se <strong>laser</strong>s are completely sealed<br />

and tested for shock and vibrati<strong>on</strong> enabling use in heavy duty operati<strong>on</strong>s in <strong>the</strong> middle <strong>of</strong> <strong>the</strong> desert,<br />

<strong>on</strong> a military aircraft, at <strong>the</strong> bottom <strong>of</strong> a mine, or in a steel factory. They combine<br />

compact size with ruggedness, reliability, and high performance. These <strong>laser</strong>s are<br />

excepti<strong>on</strong>ally durable and <strong>the</strong>y are capable <strong>of</strong> withstanding a wide temperature<br />

range while operating reliably. They can be fitted with harm<strong>on</strong>ic generators or eyesafe<br />

OPO (1.57 µm) modules and can be c<strong>on</strong>trolled via an erg<strong>on</strong>omic remote box, a<br />

set <strong>of</strong> BNC c<strong>on</strong>nectors, or an RS232 link.<br />

Power supply 435x360x135 Depends <strong>on</strong> repetiti<strong>on</strong> frequency<br />

These <strong>laser</strong>s are available with a variety <strong>of</strong> opti<strong>on</strong>al additi<strong>on</strong>al features such as motorized variable attenuators.<br />

For more informati<strong>on</strong>, request a detailed brochure.<br />

Centuri<strong>on</strong><br />

The Centuri<strong>on</strong> combines extraordinary performance with <strong>the</strong> simplicity <strong>of</strong> using diode pumping.<br />

Cooling is provided by c<strong>on</strong>ducti<strong>on</strong> or c<strong>on</strong>vecti<strong>on</strong>. The power dissipati<strong>on</strong> is 150 watts when <strong>the</strong><br />

<strong>laser</strong> is operating at full load. The Centuri<strong>on</strong> is part <strong>of</strong> our Big Sky Laser product line <strong>of</strong>fering you<br />

tough, compact, and envir<strong>on</strong>mentally sealed <strong>laser</strong> products which are built and tested to military<br />

standards. Its sealed optical cavity housing is tested against temperature variati<strong>on</strong>s as well as<br />

shock and vibrati<strong>on</strong>. It is designed for use in hostile envir<strong>on</strong>ments and for demanding<br />

industrial applicati<strong>on</strong>s. The cables are fully detachable and <strong>the</strong> 19 inch rack format<br />

power supply is interchangeable. Dedicated PC based s<strong>of</strong>tware is provided with<br />

<strong>the</strong> system for c<strong>on</strong>trol. The Centuri<strong>on</strong> stands out as an essential tool for materials<br />

processing, micro-machining, or LIDAR applicati<strong>on</strong>s.<br />

Multimode<br />

Energy (mJ) 1064 nm 40<br />

≤100<br />

532 nm 20<br />

355 nm 6<br />

266 nm 2<br />

Pulse durati<strong>on</strong> (ns) 8<br />

Beam divergence (mrad)


Brilliant EaZy<br />

Brilliant B<br />

Pulsed Nd:YAG Laser Oscillators<br />

Res<strong>on</strong>ator type<br />

Brilliant EaZy is <strong>the</strong> result <strong>of</strong> combining state <strong>of</strong> <strong>the</strong> art optical comp<strong>on</strong>ents and architecture with<br />

top <strong>of</strong> <strong>the</strong> line electr<strong>on</strong>ics. It takes <strong>the</strong> versatility <strong>of</strong> <strong>the</strong> Brilliant family <strong>of</strong> products and combines it<br />

with ease <strong>of</strong> use features such as detachable cables, electr<strong>on</strong>ic box, ability to work horiz<strong>on</strong>tally or<br />

vertically, USB c<strong>on</strong>nectors, universal transformer, and transportability. Brilliant EaZy also includes a<br />

heating element in its cooling circuits resulting in a shorter <strong>laser</strong> warm-up time. The <strong>laser</strong> head is<br />

available in four colors for customers wanting to add a little warmth to <strong>the</strong>ir laboratory. Similar to<br />

<strong>the</strong> Brilliant series <strong>of</strong> <strong>laser</strong>s, Brilliant EaZy comes with a 12 m<strong>on</strong>ths guarantee, including <strong>the</strong> optics.<br />

Brilliant EaZy is <strong>the</strong> same Brilliant idea in a compact EaZy package.<br />

Brilliant<br />

GRM<br />

Repetiti<strong>on</strong> rate (Hz) 10<br />

Energy (mJ) 1064 nm 330<br />

532 nm 165<br />

355 nm 90<br />

266 nm 35<br />

Pulse durati<strong>on</strong> (ns) 5<br />

Beam divergence (mrad)


YG900<br />

Multi-Pulse Lasers<br />

<str<strong>on</strong>g>Quantel</str<strong>on</strong>g> multi-pulse <strong>laser</strong>s are built by combining 2 compact<br />

independent <strong>laser</strong> oscillators in <strong>on</strong>e harm<strong>on</strong>ic generator. The<br />

resulting assembly delivers dual pulses in <strong>the</strong> visible spectrum<br />

with adjustable time delays. Our broad range <strong>of</strong> products covers<br />

all visualizati<strong>on</strong> requirements in fluid dynamics. Numerous<br />

opti<strong>on</strong>s and combinati<strong>on</strong>s are possible. These include manual<br />

or motorized attenuators, frequency tripling or quadrupling for<br />

access to wavelengths in <strong>the</strong> ultraviolet range <strong>of</strong> spectrum, <strong>laser</strong><br />

dye pumping, and Single L<strong>on</strong>gitudinal Mode (SLM) operati<strong>on</strong> for<br />

holographic PIV. These products are durable rugged <strong>laser</strong> systems<br />

which are highly reliable. They are also available with wavelengths<br />

in <strong>the</strong> infrared range <strong>of</strong> <strong>the</strong> spectrum, suitable for dual pulse LIBS<br />

applicati<strong>on</strong>s.<br />

Model Energy @ 532 nm (mJ) Repetiti<strong>on</strong> rate (Hz) *<br />

Twins 30 2 x 30 20<br />

Twins 50 2 x 50 20<br />

Twins 120 2 x 120 15<br />

Twins 150 2 x 150 10<br />

Twins 190 2 x 190 15<br />

Twins 200 2 x 200 10<br />

Twins 380 2 x 380 10<br />

Modular Lasers<br />

The YG900 Modular Lasers <strong>of</strong>fered by <str<strong>on</strong>g>Quantel</str<strong>on</strong>g> are all solid-state picosec<strong>on</strong>d systems. Thanks to<br />

an innovative and high performance method, it is not necessary to use saturable absorbers, liquid<br />

or solid, which are unstable and have a limited lifetime. Our <strong>laser</strong>s have excellent pulse-to-pulse<br />

stability in additi<strong>on</strong> to excepti<strong>on</strong>al reliability. Using <strong>the</strong> same modular design as <strong>the</strong> YG980 series,<br />

<strong>the</strong>y <strong>of</strong>fer high energy pulses with typical pulse durati<strong>on</strong> <strong>of</strong> 35<br />

ps. As is <strong>the</strong> case with o<strong>the</strong>r <str<strong>on</strong>g>Quantel</str<strong>on</strong>g> <strong>laser</strong>s, <strong>the</strong> YG900 comes<br />

with numerous opti<strong>on</strong>s. You can generate different harm<strong>on</strong>ics<br />

but also different pulse lengths. Combining ease <strong>of</strong> use, stability,<br />

c<strong>on</strong>trast, and simple synchr<strong>on</strong>izati<strong>on</strong>, <strong>the</strong>se unique <strong>laser</strong> tools<br />

integrate perfectly into your laboratory.<br />

Model* YG901 YG901C<br />

Repetiti<strong>on</strong> rate (Hz) 10 30 10 20<br />

Energy (mJ) 1064 nm 50 35 100 60<br />

532 nm 25 15 50 30<br />

355 nm 10 5 17 10<br />

266 nm 5 2 10 4<br />

Pulse durati<strong>on</strong> (ns) 35 35 35 35<br />

Dimensi<strong>on</strong>s (LxWxH, mm) Laser head 1150x430x280<br />

Power supply<br />

About ten different models are available in <strong>the</strong> YG900 series.<br />

For more informati<strong>on</strong>, request a detailed brochure.<br />

890x800x550<br />

* O<strong>the</strong>r repetiti<strong>on</strong> rates are available.<br />

For more informati<strong>on</strong>, request a detailed brochure.<br />

Yasmin<br />

PIV<br />

Particle Image Velocimetry (PIV) is<br />

a n<strong>on</strong>-intrusive optical method for<br />

measuring particle velocity in a flow<br />

stream, based <strong>on</strong> two successive images<br />

taken in a very short time interval.<br />

The two light pulses are delivered by<br />

two <strong>laser</strong>s and images are recorded<br />

by a Charge Coupled Device (CCD)<br />

camera. Computer processing using<br />

correlati<strong>on</strong> techniques allows determinati<strong>on</strong> <strong>of</strong> successive positi<strong>on</strong>s <strong>of</strong> a particle and<br />

rec<strong>on</strong>structi<strong>on</strong> <strong>of</strong> <strong>the</strong> flow being studied. This method is used in flow dynamic studies<br />

such as performed in <strong>the</strong> automotive and <strong>the</strong> aer<strong>on</strong>autic industries.<br />

Credits: Pininfarina – Italy<br />

Yasmin is a family <strong>of</strong> high repetiti<strong>on</strong> rate Nd:YAG pulsed <strong>laser</strong>s. These <strong>laser</strong>s are designed and<br />

developed for industrial applicati<strong>on</strong>s and for operati<strong>on</strong> in envir<strong>on</strong>mentally hostile situati<strong>on</strong>s.<br />

They can be used in ultras<strong>on</strong>ic generati<strong>on</strong> systems for thickness or defect measurement, surface<br />

preparati<strong>on</strong> such as deflashing in micro-electr<strong>on</strong>ics industry,<br />

or ablati<strong>on</strong> processes. These <strong>laser</strong>s are hermetically sealed<br />

and dust free. They can work intensively 24 hours a day and<br />

7 days a week. Active c<strong>on</strong>trol <strong>of</strong> flash lamp voltage results in<br />

a guaranteed lifetime <strong>of</strong> 200 milli<strong>on</strong> pulses. The Yasmin <strong>laser</strong><br />

emits in <strong>the</strong> infrared, visible, or ultraviolet spectrum and is<br />

suited for <strong>the</strong> processing and <strong>the</strong> treatment <strong>of</strong> a wide range <strong>of</strong><br />

materials. These <strong>laser</strong> sources can be coupled to scanners for<br />

faster area coverage.<br />

Model IR/O IR/OA Vis/O Vis/OA UV/OA<br />

Wavelength (nm) 1064 1064 532 532 355<br />

Repetiti<strong>on</strong> rate (Hz) 120 120 120 120 50<br />

Energy (mJ) >415 >200 >165 >80 >60<br />

Mean power (W) 50 25 20 10 3<br />

Pulse durati<strong>on</strong> (ns) 10 10 10 10 10<br />

For more informati<strong>on</strong>, request a detailed brochure.<br />

8-9 www.quantel-<strong>laser</strong>.com


YG980<br />

TDL90<br />

Modular Lasers<br />

The YG980 family <strong>of</strong> modular Q-switched <strong>laser</strong>s is c<strong>on</strong>tinuously improving<br />

and undergoing <strong>new</strong> developments. These <strong>laser</strong>s include a number <strong>of</strong> high<br />

energy opti<strong>on</strong>s in green and blue. Depending <strong>on</strong> <strong>the</strong> model, <strong>the</strong> <strong>laser</strong> beam<br />

generated in <strong>the</strong> oscillator is amplified through <strong>on</strong>e or more pumping <strong>laser</strong><br />

cavities to achieve energies up to 2.5 joules per pulse for a typical pulse<br />

durati<strong>on</strong> <strong>of</strong> 10 ns. As is <strong>the</strong> case with o<strong>the</strong>r product families <strong>of</strong> <str<strong>on</strong>g>Quantel</str<strong>on</strong>g><br />

<strong>laser</strong>s, <strong>the</strong>se systems also boast excepti<strong>on</strong>al stability, excellent beam quality,<br />

and a short warm-up time which is achieved through heating <strong>of</strong> <strong>the</strong> bench.<br />

Available are a set <strong>of</strong> harm<strong>on</strong>ic generators, up to <strong>the</strong> fifth harm<strong>on</strong>ic. Line<br />

narrowing opti<strong>on</strong>s, including Single L<strong>on</strong>gitudinal Mode (SLM) operati<strong>on</strong>,<br />

provide excellent coherence length. There is a wide range <strong>of</strong> various choices<br />

which make it possible to modify <strong>the</strong> specificati<strong>on</strong>s <strong>of</strong> <strong>the</strong> <strong>laser</strong> to suit your<br />

applicati<strong>on</strong> specific requirements.<br />

Tunable Lasers<br />

The TDL90 is a tunable dye <strong>laser</strong> which has a universal platform that can be pumped by any<br />

pulsed Nd:YAG <strong>laser</strong> commercially available in <strong>the</strong> market. It is especially well suited for coupling<br />

to <strong>the</strong> Brilliant and YG980 <strong>laser</strong> families. It is a narrow bandwidth<br />

<strong>laser</strong> system which is ideal for fine spectroscopy applicati<strong>on</strong>s. The<br />

accessible emissi<strong>on</strong> spectrum <strong>of</strong> this <strong>laser</strong> extends from 200 nm to<br />

4.5 µm thanks to <strong>the</strong> harm<strong>on</strong>ic generati<strong>on</strong> opti<strong>on</strong>s and frequency<br />

mixing in different n<strong>on</strong>-linear crystals. The reproducibility <strong>of</strong><br />

wavelength tunability is achieved through <strong>the</strong> use <strong>of</strong> a real time<br />

feedback loop which is associated to a dedicated user-friendly<br />

s<strong>of</strong>tware. Pulse-to-pulse stability is achieved by active c<strong>on</strong>trol <strong>of</strong> <strong>the</strong><br />

oscillator and <strong>the</strong> crystal temperature. The versatility <strong>of</strong> <strong>the</strong> TDL90<br />

<strong>laser</strong> makes it <strong>the</strong> ideal tool for your spectroscopy applicati<strong>on</strong>s.<br />

Model* YG981 YG981E YG982E<br />

Repetiti<strong>on</strong> rate (Hz) 10 50 10 30 10<br />

Energy (mJ) 1064 nm 650 500 1600 1400 2500<br />

532 nm 320 170 820 650 1250<br />

355 nm 140 85 490 400 850<br />

266 nm 60 30 150 100 230<br />

Pulse durati<strong>on</strong> (ns) 6-8 8-11 8-11 8-11 9-12<br />

Wavelength (nm) 205 222 280 367 510 560 615<br />

Process 3ω 2ω + IR 2ω ω + IR ω ω ω<br />

Typical energy (mJ)<br />

* 600 mJ pump at 532 nm 4 7 36 44 160 120<br />

* 280 mJ pump at 355 nm 27<br />

* Using a YG981C-10.<br />

For more informati<strong>on</strong>, request a detailed brochure.<br />

Dimensi<strong>on</strong>s (LxWxH, mm) Laser head 860x430x280 1150x430x280<br />

Power supply 700x800x550 1150x800x550<br />

About fifteen different models are available in <strong>the</strong> YG980 series<br />

For more informati<strong>on</strong>, request a detailed brochure.<br />

Rainbow<br />

CARS<br />

The Coherent Anti-Stokes Raman<br />

Scattering (CARS) spectroscopic<br />

method is a pump probe measurement<br />

<strong>of</strong> <strong>the</strong> Raman frequency <strong>of</strong>fset <strong>of</strong> <strong>the</strong><br />

radiati<strong>on</strong> emitted by a molecular<br />

This Optical Parametric Oscillator (OPO) is <strong>the</strong> ideal complement for <strong>the</strong> Brilliant series <strong>of</strong> <strong>laser</strong>s.<br />

It <strong>of</strong>fers a compact soluti<strong>on</strong> to researchers looking for a broadband tunable light source. It is<br />

integrated into a hermetically sealed module that fits directly<br />

<strong>on</strong>to harm<strong>on</strong>ic generators <strong>of</strong> <strong>the</strong> Brilliant or Brilliant B series. This<br />

results in excellent mechanical stability for optimum performance.<br />

Depending <strong>on</strong> <strong>the</strong> specific spectral range required, it can be pumped<br />

at <strong>the</strong> wavelengths <strong>of</strong> 532 nm, 355 nm, or 266 nm. The unit can be<br />

c<strong>on</strong>trolled by a computer. It is possible to couple some models <strong>of</strong><br />

<strong>the</strong> Rainbow <strong>laser</strong>, specifically those emitting in <strong>the</strong> visible range<br />

<strong>of</strong> <strong>the</strong> spectrum, to an optical fiber for increased flexibility and<br />

simplified integrati<strong>on</strong>.<br />

species subject to intense <strong>laser</strong> beams,<br />

such as <strong>the</strong> emissi<strong>on</strong> output <strong>of</strong> a YG980<br />

and TDL90 <strong>laser</strong> system. A combinati<strong>on</strong><br />

<strong>of</strong> 3 phot<strong>on</strong>s in <strong>the</strong> envir<strong>on</strong>ment being<br />

studied generates a fourth phot<strong>on</strong> whose characteristics determine <strong>the</strong> temperature and <strong>the</strong><br />

c<strong>on</strong>centrati<strong>on</strong> <strong>of</strong> different gasses. Using this technique it is possible to obtain <strong>the</strong> rotati<strong>on</strong>alvibrati<strong>on</strong>al<br />

structure <strong>of</strong> a material at ambient temperature. This technique is particularly suitable<br />

for analyzing CO2 emissi<strong>on</strong>s from engines.<br />

Modèle UVIS VIR NIRD<br />

Wavelength range (nm)<br />

Pump <strong>laser</strong><br />

Signal<br />

Idler<br />

Type<br />

Wavelength (nm)<br />

Energy at 10 Hz (mJ)<br />

340 – 475 410 – 680 680 – 970<br />

NA 720 – 1100 1200 – 2000<br />

Brilliant<br />

Brilliant – Brilliant B<br />

266 355 532<br />

40 100 – 200 180 – 400<br />

For more informati<strong>on</strong>, request a detailed brochure.<br />

10-11 www.quantel-<strong>laser</strong>.com


Nd:Glass Laser Systems<br />

Since its creati<strong>on</strong>, <str<strong>on</strong>g>Quantel</str<strong>on</strong>g> has specialized in manufacturing<br />

<strong>laser</strong> systems delivering large pulse energies or high peak power<br />

outputs. Some <strong>of</strong> <strong>the</strong> <strong>laser</strong> systems built by <str<strong>on</strong>g>Quantel</str<strong>on</strong>g> have been<br />

operating for 30 years without a decrease in performance.<br />

<str<strong>on</strong>g>Quantel</str<strong>on</strong>g> has a l<strong>on</strong>g list <strong>of</strong> reference customers, which are a<br />

measure <strong>of</strong> outstanding customer satisfacti<strong>on</strong> achieved through<br />

<strong>of</strong>fering <strong>of</strong> excepti<strong>on</strong>ally high quality and reliable products.<br />

The l<strong>on</strong>g list <strong>of</strong> satisfied customers <strong>of</strong> <str<strong>on</strong>g>Quantel</str<strong>on</strong>g> include <strong>the</strong><br />

following organizati<strong>on</strong>s: Sandia Labs and LLNL in <strong>the</strong> United States; University <strong>of</strong> Warsaw in Poland;<br />

FOM in Holland; University <strong>of</strong> Bern in Switzerland; CAT in India; Ru<strong>the</strong>rford Applet<strong>on</strong> Laboratory in<br />

Great Britain; LIXAM, <strong>the</strong> Polytechnique engineering school and <strong>the</strong> Atomic Energy Commissi<strong>on</strong> in<br />

France.<br />

The design <strong>of</strong> <str<strong>on</strong>g>Quantel</str<strong>on</strong>g>’s glass <strong>laser</strong>s is based <strong>on</strong> a series <strong>of</strong> ceramic diffuser pumping chambers.<br />

Their diameter varies from 6 mm to 90 mm. The neodymium-doped glass allows a lot <strong>of</strong> energy to<br />

be stored. Its <strong>the</strong>rmal properties allow repetiti<strong>on</strong> rates as high as 0.1 Hz.<br />

Pumping cavity SFC6 SFC9 SFC12 SFC16 SFC25 SFC45 SFC64 SFC90<br />

Bar diameter (mm) 6 9 12 16 25 45 64 90<br />

Bar diameter (mm) 2 2 4 4 4 8 10 12<br />

Typical energy in 40 ns (J) 1 2 4 25 70 220 450 850<br />

Q-Switched Laser Systems<br />

Each <strong>laser</strong> system <strong>of</strong> this type is adapted to <strong>the</strong> specific customer needs and meets a precise set<br />

<strong>of</strong> specificati<strong>on</strong>s. The <strong>laser</strong> oscillator can use doped glass, Nd:YLF or Nd:YAG as <strong>the</strong> active material.<br />

To reach <strong>the</strong> required level <strong>of</strong> energy, amplificati<strong>on</strong> is achieved by matching pumping chambers<br />

<strong>of</strong> increasing diameters allowing<br />

compensati<strong>on</strong> for birefringence. Pulse<br />

durati<strong>on</strong> is in <strong>the</strong> order <strong>of</strong> 10 ns to 50<br />

ns. Harm<strong>on</strong>ic generati<strong>on</strong> and beam<br />

homogenizati<strong>on</strong> opti<strong>on</strong>s are available for<br />

pumping applicati<strong>on</strong>s such as those using<br />

Titanium-Sapphire crystals.<br />

High Energy Free-Running Lasers<br />

Crédits : LIXAM – France<br />

Custom-Built Laser Soluti<strong>on</strong>s and Engineering Services<br />

Credits: JET-EFDA – Great Britain<br />

<str<strong>on</strong>g>Quantel</str<strong>on</strong>g> <strong>of</strong>fers a wide range <strong>of</strong> standard <strong>laser</strong> soluti<strong>on</strong>s for many different types <strong>of</strong> applicati<strong>on</strong>.<br />

However, <strong>the</strong> <str<strong>on</strong>g>Quantel</str<strong>on</strong>g> engineering teams can also design and create for you custom-built <strong>laser</strong><br />

systems which meet a set <strong>of</strong> your predefined applicati<strong>on</strong> specific requirements. We can modify<br />

or upgrade <strong>on</strong>e <strong>of</strong> our standard <strong>laser</strong>s to meet certain specific customer requirements and<br />

envir<strong>on</strong>mental c<strong>on</strong>straints, or we could design for you a completely custom-built <strong>laser</strong> system.<br />

Q-Switched Nd:YAG Laser for Thoms<strong>on</strong> Diffusi<strong>on</strong> Measurement<br />

This <strong>laser</strong> was designed using standard comp<strong>on</strong>ents <strong>of</strong> our YG980 series <strong>of</strong> products and it was<br />

intended for metrology applicati<strong>on</strong>s for <strong>the</strong> European Tokamak installed at Culham in Great Britain<br />

(JET-EFDA). The main technological challenge <strong>of</strong> this system was to obtain a high level <strong>of</strong> pulse<br />

energy - greater than 5 joules <strong>of</strong> infrared energy - delivered in less than 10 ns, a repetiti<strong>on</strong> rate <strong>of</strong><br />

20 Hz and linear polarizati<strong>on</strong> purity greater than 98%, all at <strong>the</strong> same<br />

time. The engineering team <strong>of</strong> <str<strong>on</strong>g>Quantel</str<strong>on</strong>g> successfully designed and<br />

built a <strong>laser</strong> that met all <strong>the</strong>se specificati<strong>on</strong>s.<br />

Laser for Undersea Holography<br />

With <strong>the</strong> target being more than 50 meters away from <strong>the</strong> <strong>laser</strong>, beam<br />

quality and beam stability were also critical parameters. C<strong>on</strong>sidering<br />

<strong>the</strong> high average power <strong>of</strong> this <strong>laser</strong> which is greater than 100 W, <strong>the</strong><br />

optical bench <strong>of</strong> this <strong>laser</strong> is relatively small; approximately 1 meter<br />

by 2 meters in size. This compact optical bench meets all <strong>the</strong> high<br />

repetiti<strong>on</strong> rate and linear polarizati<strong>on</strong> specificati<strong>on</strong>s required for this<br />

demanding applicati<strong>on</strong>. The system is c<strong>on</strong>trolled through <strong>the</strong> local<br />

E<strong>the</strong>rnet network.<br />

When you want to take 3D holographic pictures <strong>of</strong> oceanic plankt<strong>on</strong> more than 100 meters below<br />

<strong>the</strong> surface <strong>of</strong> <strong>the</strong> sea, it is difficult to find <strong>the</strong> ideal <strong>laser</strong> source in a catalog <strong>of</strong> standard products.<br />

For this project <str<strong>on</strong>g>Quantel</str<strong>on</strong>g> designed a special Nd:YAG oscillator-amplifier <strong>laser</strong>, passively Q-Switched<br />

by a saturable absorber to provide sufficient coherence length. The harm<strong>on</strong>ic generati<strong>on</strong> <strong>of</strong> this<br />

system was also designed carefully so that phase<br />

matching would not be critical. Cooling <strong>of</strong> <strong>the</strong><br />

<strong>laser</strong> source was provided by <strong>the</strong> sea water. The<br />

<strong>laser</strong>-camera assembly was mounted in a casing<br />

specially designed by our customer. The principal<br />

technical specificati<strong>on</strong> was an output energy <strong>of</strong><br />

300 mJ emitted at <strong>the</strong> wavelength <strong>of</strong> 532 nm with<br />

<strong>the</strong> repetiti<strong>on</strong> rate <strong>of</strong> 1 Hz, and a coherence length<br />

which had to be greater than 1 meter.<br />

These <strong>laser</strong>s are used principally for measurements <strong>of</strong> <strong>the</strong>rmal diffusivity. Their pulse durati<strong>on</strong> is<br />

in <strong>the</strong> range <strong>of</strong> a few hundred <strong>of</strong> microsec<strong>on</strong>ds, depending <strong>on</strong> <strong>the</strong> specific type <strong>of</strong> discharge circuit<br />

which is used. The energy delivered can reach several hundred <strong>of</strong> joules per pulse, generated by a<br />

<strong>laser</strong> with a relatively small size.<br />

Credits: University <strong>of</strong> Southampt<strong>on</strong> – Great Britain<br />

12-13<br />

www.quantel-<strong>laser</strong>.com


OEM Soluti<strong>on</strong>s<br />

Examples<br />

<str<strong>on</strong>g>Quantel</str<strong>on</strong>g> <strong>of</strong>fers OEM soluti<strong>on</strong>s to manufacturers who integrate <strong>laser</strong> sources into <strong>the</strong>ir industrial,<br />

medical, or military systems. Close collaborati<strong>on</strong> is established between our customers and <strong>the</strong><br />

various teams at <str<strong>on</strong>g>Quantel</str<strong>on</strong>g> in order to precisely define <strong>the</strong> most suitable system for each customer<br />

and for each applicati<strong>on</strong>. We build with our customers pr<strong>of</strong>essi<strong>on</strong>al working relati<strong>on</strong>ships that last<br />

for a l<strong>on</strong>g time.<br />

The services <strong>of</strong>fered by <str<strong>on</strong>g>Quantel</str<strong>on</strong>g> include customer visits to make an assessment <strong>of</strong> <strong>the</strong> project as well<br />

as technical meetings with teams from R&D, electr<strong>on</strong>ic, or mechanical design groups. All parameters<br />

are taken into c<strong>on</strong>siderati<strong>on</strong> and fully analyzed. These could include, am<strong>on</strong>g many o<strong>the</strong>r things,<br />

such c<strong>on</strong>siderati<strong>on</strong>s as c<strong>on</strong>straints associated with <strong>the</strong> specific applicati<strong>on</strong> or <strong>the</strong> envir<strong>on</strong>ment,<br />

type <strong>of</strong> industry, system dimensi<strong>on</strong>s, electrical c<strong>on</strong>necti<strong>on</strong>s, and hardware or s<strong>of</strong>tware interfacing<br />

issues. The soluti<strong>on</strong>s proposed can involve simple modificati<strong>on</strong>s made to our standard products or<br />

design and creati<strong>on</strong> <strong>of</strong> a specific innovative prototypes.<br />

Customizati<strong>on</strong> and special engineering services are also available. We think <strong>of</strong> everything in great<br />

detail so that you receive <strong>the</strong> best service and <strong>the</strong> highest quality product available from any <strong>laser</strong><br />

manufacturer. Customer satisfacti<strong>on</strong> through <strong>of</strong>fering <strong>of</strong> <strong>the</strong> highest quality products and services<br />

is our primary objective.<br />

Military and Aerospace Soluti<strong>on</strong>s<br />

At our factory we have a dedicated large size clean<br />

room <strong>of</strong> about 320 m² which is ISO 8 certified.<br />

O<strong>the</strong>r tools include test benches for vibrati<strong>on</strong>,<br />

shock, and temperature characterizati<strong>on</strong>s as well<br />

as optical, mechanical, and <strong>the</strong>rmo-mechanical<br />

simulati<strong>on</strong> s<strong>of</strong>twares.<br />

The Megajoule Laser Project<br />

For many years <str<strong>on</strong>g>Quantel</str<strong>on</strong>g> has been heavily involved<br />

in <strong>the</strong> aerospace and military projects, mainly those<br />

related to <strong>the</strong> design and development <strong>of</strong> diodepumped<br />

switched <strong>laser</strong> sources with applicati<strong>on</strong>s<br />

associated with <strong>on</strong>-board systems, missile guidance,<br />

target designati<strong>on</strong>, space LIDAR, and document<br />

au<strong>the</strong>nticati<strong>on</strong>. These are <strong>on</strong>ly a few examples <strong>of</strong> <strong>the</strong><br />

numerous military applicati<strong>on</strong>s and projects which<br />

<str<strong>on</strong>g>Quantel</str<strong>on</strong>g> has participated in. We have successfully<br />

designed, built, and delivered numerous special <strong>laser</strong><br />

soluti<strong>on</strong>s to <strong>the</strong> military and aerospace customers.<br />

The Megajoule <strong>laser</strong> is an essential element <strong>of</strong> <strong>the</strong> French Atomic Energy Commissi<strong>on</strong>’s Simulati<strong>on</strong><br />

program, which is intended to provide a l<strong>on</strong>g-lasting deterrent after <strong>the</strong> permanent end to nuclear<br />

tests. <str<strong>on</strong>g>Quantel</str<strong>on</strong>g> is involved in <strong>the</strong> design and manufacturing <strong>of</strong> pre-amplificati<strong>on</strong> <strong>laser</strong> modules which<br />

are designed to put in shape, both spatially and temporally, <strong>the</strong> beam coming from <strong>the</strong> injecti<strong>on</strong><br />

fiber source. This project requires <strong>the</strong> combined skills <strong>of</strong> our lamp pumping and diode pumping<br />

<strong>laser</strong> design engineering teams. This project serves as a launching platform for <strong>the</strong> development<br />

and understanding <strong>of</strong> a variety <strong>of</strong> <strong>new</strong> <strong>technologies</strong> as well as <strong>the</strong> implementati<strong>on</strong> <strong>of</strong> project<br />

management and process quality c<strong>on</strong>trol tools.<br />

The ALADIN Project<br />

Credits: CRIEPI – Japan<br />

<str<strong>on</strong>g>Quantel</str<strong>on</strong>g> has been c<strong>on</strong>tracted by <strong>the</strong> European Space Agency to design and build <strong>the</strong> flight module<br />

<strong>laser</strong> amplifiers for <strong>the</strong> ALADIN <strong>laser</strong> project which is a part <strong>of</strong> <strong>the</strong> Aeolus program.<br />

Credits: Applied Phot<strong>on</strong>ics – UK<br />

The word ALADIN is an acr<strong>on</strong>ym for Atmospheric LAser Doppler<br />

INstrument. This is a highly sophisticated instrument which is<br />

designed to measure <strong>the</strong> speed <strong>of</strong> atmospheric winds. The goal<br />

is improvement <strong>of</strong> meteorological forecasting models.<br />

Photophysics<br />

Credits: Galileo Avi<strong>on</strong>ica – Italy<br />

The <strong>laser</strong> emits pulses <strong>of</strong> 150 mJ at 355 nm and 100 Hz in a<br />

burst mode. This program is being carried out in partnership<br />

with Galileo Avi<strong>on</strong>ica (Italy) under <strong>the</strong> directi<strong>on</strong> <strong>of</strong> EADS-Astrium<br />

(European Aer<strong>on</strong>autic Defense and Space company). At <str<strong>on</strong>g>Quantel</str<strong>on</strong>g><br />

we designed and manufactured <strong>the</strong> multi-passage zig-zag<br />

type <strong>of</strong> amplifier in diode-pumped <strong>laser</strong> heads which is used to<br />

amplify <strong>the</strong> energy <strong>of</strong> an 8 mJ oscillator to about 500 mJ, under<br />

c<strong>on</strong>diti<strong>on</strong>s <strong>of</strong> space vacuum and without <strong>the</strong> use <strong>of</strong> any active<br />

cooling mechanism.<br />

14-15<br />

www.quantel-<strong>laser</strong>.com


<str<strong>on</strong>g>Quantel</str<strong>on</strong>g><br />

2 bis, Avenue du Pacifique - Z.A. de Courtaboeuf - B.P. 23<br />

91941 Les Ulis Cedex - France<br />

Tél : + 33 (0)1 69 29 17 00 - Fax : + 33 (0)1 69 29 17 29<br />

<str<strong>on</strong>g>Quantel</str<strong>on</strong>g> - USA<br />

601 Haggerty Lane<br />

Bozeman, MT 59715 - 2001 - USA<br />

Tél : + 1 406 586 0131 - fax : + 1 406 586 2924<br />

<str<strong>on</strong>g>Quantel</str<strong>on</strong>g> - Allemagne<br />

Im Tiefen See 58<br />

64293 Darmstadt - Allemagne<br />

Tél : + 49 (0) 6151 8806 475 - Fax : + 49 (0) 6151 8806 9475<br />

www.quantel-<strong>laser</strong>.com<br />

BM January 2008

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!