Construction site lighting Portable fittings for ... - Palissy Galvani

palissygalvani.pt

Construction site lighting Portable fittings for ... - Palissy Galvani

Construction site lighting Portable fittings for incandescent and blended lamps

Light fittings which are to be

used on construction sites have

to fulfil specific requirements. It

must be possible to install them

quickly and safely and at the

same time they have to withstand

extreme conditions. The

tried and tested range of construction

site light fittings from

Meyer meets these criteria.

The high protection

rate of these

construction site

light fittings makes

it possible for them

to be used in an

interior or exterior

environment.

22

Construction site lighting


Fittings with

narrow and wide

beam reflectors

are available.

They can be

supplied with or

without cable.

The light fittings

are supplied with

either a wire

bracket or flat

steel bracket for

attaching the

luminaire to a

tripod or

scaffolding etc.

Construction site lighting

23


R 500

R 500

For incandescent lamps (A) and

blended lamps (HME-SB)

protection class II ,

IP54 (plug IP44 )

EN EC

10

lighthead made of glass fibre reinforced polyester,

matt anodized aluminium reflector, tempered safety

glass, gasket with impact absorbing rubber ring,

polyester powder coated protection guard,

5 stainless steel clamps, galvanized steel wire

bracket or flat steel bracket, cable connection

through rubber grommet, supplied without lamp

Construction site lighting

R 500, without cable

Part number Lamp Lampholder Weight cable

8 550 038 000 A110 500 W E40 4.0 kg –

A110 500 W

8400 lm

8550038

Ø 5,7 m

Ø 8,5 m

Ø 11,4 m

Ø 14,2 m

90

60

150

300

I (cd/klm)

90

60

R 500, without cable, with flat steel bracket

Part number Lamp Lampholder Weight cable

8 550 058 000 A110 500 W E40 4.4 kg –

Ø 2,8 m

269 lx 67 lx 30 lx 17 lx 11 lx

Abstand/Distance 3 m 6 m 9 m 12 m 15 m

450

600

R 500, with cable

Part number Lamp Lampholder Weight cable

8 550 438 000 A110 500 W E40 5.1 kg 10 m rubber cable H07RN-F2x1

with contour plug

R 500, with cable, with flat steel bracket

Part number Lamp Lampholder Weight cable

8 550 458 000 A110 500 W E40 5.5 kg 10 m rubber cable H07RN-F2x1

with contour plug

VDE/ENEC certification applies to luminaires with cable only.

Accessories

Part number Colour Description

125 0 003 000 unpainted Flat steel bracket FS 40 with clamp, galvanized,

for attaching the luminaire to pipes, poles or stands

Lamp

Part number Type Output (W) Cap

230 0 195 000 A110, incandescent,

impact resistant

500 E40

24

R 500

Lamp


R 500 S

with rubber power socket

For incandescent lamps (A) and

blended lamps (HME-SB)

protection class I, IP44

EN EC

10

lighthead made of glass fibre reinforced polyester,

matt anodized aluminium reflector, tempered safety

glass, gasket with impact absorbing rubber ring,

polyester powder coated protection guard,

5 stainless steel clamps, galvanized steel wire

bracket or flat steel bracket, cable connection

through rubber grommet, supplied without lamp

Construction site lighting

R 500 S

90

60

150

300

I (cd/klm)

90

60

A110 500 W

8400 lm

8552038

Ø 5,7 m

Ø 8,5 m

Ø 11,4 m

Ø 14,2 m

R 500 S, without cable

Part number Lamp Lampholder Weight cable

8 552 038 000 A110 500 W E40 4.1 kg –

450

600

Abstand/Distance

Ø 2,8 m

269 lx

3 m

67 lx

6 m

30 lx

9 m

17 lx

12 m

11 lx

15 m

R 500 S, without cable, with flat steel bracket

Part number Lamp Lampholder Weight cable

8 552 058 000 A110 500 W E40 4.5 kg –

R 500 S, with cable

Part number Lamp Lampholder Weight cable

8 552 538 000 A110 500 W E40 5.6 kg 10 m rubber cable H07RN-F2x1

with contour plug

R 500 S, with cable, with flat steel bracket

Part number Lamp Lampholder Weight cable

8 552 558 000 A110 500 W E40 6.0 kg 10 m rubber cable H07RN-F2x1

with contour plug

VDE/ENEC certification applies to luminaires with cable only.

Accessories

Part number Colour Description

125 0 003 000 unpainted Flat steel bracket FS 40 with clamp, galvanized,

for attaching the luminaire to pipes, poles or stands

Lamp

Part number Type Output (W) Cap

230 0 195 000 A110, incandescent, impact

resistant

500 E40

This version of the

construction site

light fittings is

equipped with a

rubber power

socket.

Lamp

R 500 S

25


R 500 B

R 500 B

For incandescent lamps (A) and

blended lamps (HME-SB)

protection class II ,

IP54 (plug IP44 )

EN EC

10

lighthead made of glass fibre reinforced polyester,

matt anodized aluminium reflector, tempered safety

glass, gasket with impact absorbing rubber ring,

polyester powder coated protection guard,

5 stainless steel clamps, galvanized steel wire

bracket or flat steel bracket, cable connection

through rubber grommet, supplied without lamp

Construction site lighting

R 500 B, without cable

Part number Lamp Lampholder Weight cable

8 555 038 000 A110 500 W E40 4.0 kg –

A110 500 W

8400 lm

8555038

Ø 2,8 m

Ø 4,2 m

Ø 5,6 m

Ø 7 m

500

I (cd/klm)

90

60

30

R 500 B, without cable, with flat steel bracket

Part number Lamp Lampholder Weight cable

8 555 058 000 A110 500 W E40 4.4 kg –

Abstand/Distance

Ø 1,4 m

764 lx 191 lx

3 m

6 m

85 lx

9 m

48 lx

12 m

31 lx

15 m

750

1000

R 500 B, with cable

Part number Lamp Lampholder Weight cable

8 555 438 000 A110 500 W E40 5.1 kg 10 m rubber cable H07RN-F2x1

with contour plug

R 500, with cable, with flat steel bracket

Part number Lamp Lampholder Weight cable

8 555 458 000 A110 500 W E40 5.5 kg 10 m rubber cable H07RN-F2x1

with contour plug

VDE/ENEC certification applies to luminaires with cable only.

Accessories

Part number Colour Description

125 0 003 000 unpainted Flat steel bracket FS 40 with clamp, galvanized,

for attaching the luminaire to pipes, poles or stands

Lamp

Part number Type Output (W) Cap

230 0 195 000 A110, incandescent,

impact resistant

500 E40

26

R 500 B

Lamp


R 500 SB

with rubber power socket

For incandescent lamps (A) and

blended lamps (HME-SB)

protection class I, IP44

EN EC

10

lighthead made of glass fibre reinforced polyester,

matt anodized aluminium reflector, tempered safety

glass, gasket with impact absorbing rubber ring,

polyester powder coated protection guard,

5 stainless steel clamps, galvanized steel wire

bracket or flat steel bracket, cable connection

through rubber grommet, supplied without lamp

Construction site lighting

R 500 SB

500

I (cd/klm)

90

60

30

A110 500 W

8400 lm

8557038

Ø 2,8 m

Ø 4,2 m

Ø 5,6 m

Ø 7 m

R 500 SB, without cable

Part number Lamp Lampholder Weight cable

8 557 038 000 A110 500 W E40 4.1 kg –

750

1000

Abstand/Distance

Ø 1,4 m

764 lx 191 lx

3 m

6 m

85 lx

9 m

48 lx

12 m

31 lx

15 m

R 500 SB, without cable, with flat steel bracket

Part number Lamp Lampholder Weight cable

8 557 058 000 A110 500 W E40 4.5 kg –

R 500 SB, with cable

Part number Lamp Lampholder Weight cable

8 557 538 000 A110 500 W E40 5.6 kg 10 M rubber cable H07RN-F2x1

with contour plug

R 500 SB, with cable, with flat steel bracket

Part number Lamp Lampholder Weight cable

8 557 558 000 A110 500 W E40 6.0 kg 10 M rubber cable H07RN-F2x1

with contour plug

VDE/ENEC certification applies to luminaires with cable only.

Accessories

Part number Colour Description

125 0 003 000 unpainted Flat steel bracket FS 40 with clamp, galvanized,

for attaching the luminaire to pipes, poles or stands

Lamp

Part number Type Output (W) Cap

230 0 195 000 A110, incandescent,

impact resistant

500 E40

This version of the

construction site

light fittings is

equipped with a

rubber power

socket.

Lamp

R 500 SB

27

More magazines by this user